Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS1t R J I OFFICE USE ONLY: Date: ,4 lltnlrA I Fee Due: Receipt# Permit # ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and Zoning _ C U���`tM � 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 772-462-1553 UCie CoUf7t APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS(: � 1 q 3 -?Aw u�'./ L-�- 2. PROJECT NAME: 'sP (0-SQ'-I SITE PLAN NAME: SOu"SCL�l_�t, _ 3. PROPERTY TAX ID #: bOc)q 4. LEGAL DESCRIPTION (attach extra sheets if necessary): UJG.A 1Xw, OA u�i gol l - Iln, low - l � 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. NO. I NO. 9. PARCEL SIZE: ACRES/SQ FT. l ��� SLOT DIMENSIONS / D / 10. SETBACKS (ACTUAL) FRONT: BACK: RIGHT SIDE: awr $kxwatEFT SIDE: Ww?-ShveY 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION - N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X CARPORT/PATIO ROOF 3 ❑ NEW DO EXISTING 3CJ X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION 3 S� 12. VALUE OF CONSTRUCTION: $ !YNdD eO The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 2119107 d OWNER INFORMATION NAME: Y�,n e ADDRESS: Sot _a> " CITY: 7> STATE: 1FX __ ZIP _tS-t 9 CJP— PHONE (DAYTIME): ao� %� EMAIL: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): ( ) CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: ekoo �0- su r1 ST. LUCIE COUNTY CERT #: 11-1 Z O BUSINESS NAME: QUALIFIER'S NAME: l CL ADDRESS: 49:Ao 1 CITY: �bdk �iQ YC� STATE: ZIP PHONE (DAYTIME): (711)j. FAX NO.'"l2, 4ke (0 l O'7 � email: ARCHITECT/ENGINEER:'C� ADDRESS:�>O CITYAn- ✓ - STATE: ZIP 2 Z, PHONE (DAYTIME): (__256W-1(0-1 - LF'1'1 4 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑. 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFFICE USE ONLY SECTION a D TOWNSHIP J RANGE '` [� MAP NO. -3 ZONING PLA LAND USE Q ] J LOT CVG 0 Additional Permits I U ` Q5 Re uired REPOR T �® BIMS FEE $ MISC FEES $ TOTAL FEES _Fs— CODE BUILDING & ZONING REVIEW FRONT PLANS VALUE OF CONSTRUCTION REVIEW COUNTER 1411&JCSUPERVISOR EXA INER VEGETATION USING ICC TABLE DATE COMPLETE y r Q(r INITIALS4&e PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: ❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 41h wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminuto stru e a said structure will not exceed the rint o e structure that was in existence prior to removal by th or O O C OR SIGNATURE CONTRACTOR SIGNATURE STATE OF FLORIDA.. COUNTY OF The foregoing instrument was acknowledged before me + me this l P day of , 20$_, by who is personally known -� to me, or who has produced , STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged before me me this ) lP day of , 20 , by who is personally known `� to me, or who has produced , as identification. as identification. Signature of Notary `i Signature j\o`f'1vNotary �0 gw p �� IMPORTANT NOTICES:��o�► N 003 • TWO (2) SIGNATURES ARE REQD. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. Code Compliance Division 2300 Virginia Avenue Alert Maintenance Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stl ucieco.gov/ce Parcel # 13425-701-0021-000/9 Jurisdiction ISt. Lucie County Permit # 10501-0109 Lists first permit on property. Reference only. Zoning I Planned Unit Development Address 8193 BLACKBEAD CT . PORT ST LUCIE 34952 Adel Item > > 4' Active Contractor Licensinc 2/08/08 CARPORT ON THE PRC 02/08/2008 barriosm 2/08/08 CARPORT ON THE 02/08/2008 barriosm PROPERTY W/ OUT A PERMIT - DOUBLE FEE PERMIT MB 1. You must enter a number in the severity column to show the information. If it's blank, there will be no light to indicate that there is a message. 2. Please reference the permit # or permit type. When there is more than one permit, it's cifficult to determine what the message is referencing. • 'i EDWIN M. FRY, Jr., CLE ' THE CIRCUIT COURT AFTER RECORDING -RETURN TO: SAINT LUCIE COUNTY ' FILE # 3138208 11/29/2007 at 01:31 PM OR BOOK 2909 PAGE 2237 - 2237 Doc Type: NC JJJ RECORDING: $10.00 PERMIT NUMBER: V /°1S2 z�yLi (� / NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. J —7 j� 1. DESCRIPTION OF PROPERTY (Legal description and street address) TAX TOLIO NUMBER: � � LL VI ���I ��O 43- 2. GENERAL DESCRIPTION OF 3. OWNER INFORMATION;, interest in property l qL� & d. Name and address of fee simple titleholder (if other than 4. CONTRACTOR'S NAME, ADDRESS AND 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date. is 1 year from the date of recording unless a different date is specified) , , 20 WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. X Signature 4ner or Print Name and Provide Signatory's Title/O ce Owner's Aized Officer/Director/Partne naa,, State of Florida County of. The foregoing instrument was ((acknowledged before me this \ day o�f "� 'y" —�~ '� 20y r By � n M IV as (� 1J c + (Name of pe(son) (Type of authority... e.g. Owner, officer, trustee, attorney in fact) For �_`T (Name of party on behalf of whom instrument was executed) Personally Known_ or produced the following type of ID: I CHRISTINA BROWN Notary Public, State of Florida Y 1 (� I'll lnSYl C LYE-- My Comm. Expires Feb. 17, 2009 (Printed Name of Notary Public) (Signature of Notary Public) No. DD39777F Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are true to the best of my knowledge and belief (section 92.525, Florida Statutes). Sig ture(s) of Owner(s) or Owner(s)' Authorized Officer/Director/Partner/Manager who signed above: By: X nh By R— 08/30/2007(R-o tline) Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1653 Fax: (772) 462-2522 http://stiucleco.gov/ce Date: 21 April 2008 Receipt #: 0000062262 Job Address: 8193 BLACKBEAD CT 'ermit Number: SLC- 0804-0236 Received By: gersteml Amount: $50.00 Paid With: CK �redit Card Number: Check Number: 13581 Paid By: SOUTH FLORIDA ALUMINUM PRODUCTS IP Sign: Code Compliance Division 2300 Virginia Avenue Alert Maintenance Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 hftp://stiucleco.gov/ce ,K0PQRMAV0,N Parcel # 3425-701-0021-000/9 Jurisdiction St. Lucie County Permit # 0501 0109 Lists first permit on property. Reference only. Zoning I Planned Unit Development Address 8193 1 BLACKBEAD CT PORT ST LUCIE 34952 Add Alec-t — 4 1 Active Contractor Licensinc 2/08/08 CARPORT ON THE PRC 02/08/2008 barriosm 2/08/08 CARPORT ON THE 02/08/2008 barnosm PROPERTY W/ OUT A PERMIT - DOUBLE FEE PERMIT MB 1. You must enter a number in the severity column to show the information. If it's blank, there will be no light to indicate that there is a message. 2. Please reference the permit # or permit type. When there is more than one permit, it's dfficult to determine what the message is referencing. ¢�C Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucieco.gov/ce Review Comments PROPERTY INFORMATION Address: 8193 BLACKBEAD CT City / State / Zip: PORT ST LUCIE FL 34952 Parcel # : 3425-701-0021-000/9 Jurisdiction: St. Lucie County Zoning: PUD Lot # : 4 Block: 1 APPLICATION INFORMATION Permit Number: 0804-0236 Activity Type: Permit Type: MA/RV Addition Existing Concrete CONTRACTOR INFORMATION Contractor Name: WHIGHAM GARY K Business Name: SOUTH FLORIDA ALUMINUM PRODUCT Business Addr: 4801 S US 1 City / State / Zil FT PIERCE, FL 3498-, REVIEWS AND COMMENTS Review Type Status Front Counter Review Complete Page 1 Owner(s): • . John M Neafsey Application Type: Building Permit w/o subs Other Activity: Stories: 1 Automatic Sprinkler System? Fax Number 772-466-1074 Reviewed By Date Started Date Complete Date Released Lorie Gerstemeier 04/21/2008 04/21/2008 Zoning Review Pending Jodee Vorreyer 04/23/2008 1 Comment 35 TRANSMISSION VERIFICATION REPORT TIME 04/23/2008 15:07 NAME FAX TEL SER.# BROH5J320634 DATE,TIME 04/23 15:07 FAX NO./NAME 94661074 DURATION 00:00:17 PAGE(S) 01 RESULT OK MODE STANDARD ECM -7 7-L.- Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 phone: (772) 462.1553 For. (772) 462-2522 http:11stlucIoco.g6v1ce PROPERTY INF_ORMA7701V Address: 8193 SLACKSEAD CT City I State I Zip. PORT ST LUCIE Parcel # : $425-701-0021.000/9 Zoning: PUD Review Comments FL 34952 Jurisdiction: St, Luole County Lot # : - 4 Block: 1 APP1-ICATI0N INFORMATION Permit Number: 004-02$6 Activity Type: Permit Type: MAIRV Addition Existing Conoreie CONTRACTOR INFORMATION Contractor Name: WHIGHAM GARY K Busines6 Name: SOUTH FLORIDA ALUMINUM PRODUCT Business Addr: 4801 5 U S 1 City I state 1 T71 REVIEWS AND COMMENT_$ Review Tvae Statu4 Front Counter Review Complete FT PIFRCE, FL 34982 Page 1 Owner(s): John M Neafsey Application Type: Building Permit w!o subs Other Activity: Stories: 1 Automatic Sprinkler System? Fax Number 772-46&1074 Reviev�e 1LB_y I_oriie Geratemeler bate Started Date Comyiete pate Release 04/2112008 04/21/2008 . Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce Issued: 05/01 /2008 Conf #: 686 Job Location: 8193 BLACKBEAD CT Permit Type: MA/RV Addition Existing Concrete Job Description: BUILDING PERMIT Permit #: SLC- 0804-0236 City: PORT ST LUCIE INSTALLATION OF CARPORT 35 X11 TOTAL 385 SQ FOR MOBILE HOME Page 1 S/D Savanna Club Plat I Lot: 4 Block: 1 Parcel: 3425-701-0021-000/9 Contractor WHIGHAM GARY K SOUTH FLORIDA ALUMINUM PRODU( (772) 466-0913 4801 S US 1 FT PIERCE, FL 34982 Property Owner JOHN M NEAFSEY (772) 340-2251 8193 BLACKBEAD CT PORT ST LUCIE, FL 34952-3314 Setbacks .Left: 16.00 Right: 19.00 Front:37.00 Rear: 20.00 Zoning: PUD Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: 295F Flood Zone: X Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there maybe additional restrictions applicable to this property that maybe found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange ok Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Code Compliance Division 2300 Virginia Avenue Fees/Pa ments x Ft Pierce, FL 34982 Y Phone: (772) 462-1553 Fax:(772) u 462-2522' tuaflugard I g 1 201v iyirmg N • n a o m Atldress° 81'93 = . BLACKBEAD' . , CT „; Owner(s) ° John M Neafsey A c .. `Unit`# City / State % Zip PSL FL 34952 r - Parcel # 3425-701-0021=000/9 Jurisdiction cty Zoning PUD uture Land Use ResidegtialaUrban Subdivision 34257.01, Block 1 .� u °•-- •INFORMATION • - �• �� Permit Type MA/RV Addition Existing Concrete„ yp , 0804=0236 -_ _. , \pplication Type -'Building P Issued � Activity Type ermit w/o subs i Other 77 .. _ w._ , _ Stories iI "a Itomatic Spnnkler System?.❑' = .., Account' �;• `p Quant -pay FEES u P ,Cod by Type •'• .- , ity „ Amount .. " Date Post$d "Paid? Fee' _ Acces653 06-Plan Review- Accessory Use - 01491 2415 322000 200 $50.00 04/21/2008 Acces653 ",,06=Plan Review -Accessory Use -,0 491 2415'322000 200 " $50.00 04/21/9008' Yes BIMS651 06-BIMS 491 2415 322056200 $5 00 05/01/2008 Yes P"erini731 ''°..`.06-Permit Fee - Screen R"m/Carport/ 49:1 2415 32200' Q 200. . , $75 00 a t 05/01Y2008 , Yes, • .; Permi693 .`a'06 Permit Fee Double Fee Constr 491 2415 322000 200 a; $75 00 05/01/2008 Yes „ , , w , Oate `Entered a 21/2008 S D.ate'Paid 004/21/2008 ;Entered By gi! steml Historical No rAMCCROMMU Receipt #= ' ; Amount , Dale Posted 0000062262 $50.00 • 04/21/2008 Paid B SOUTH FLORIDA ALUMINUM PRODUCTS •; 0000062487 : e �$155,00 05/01 /2008 ` �y� "a Payment Type CK Check (CK), Cash (CA),,; Check # 13602 Mastercard (MC),, Visa (VS), Fee Waived (FW), Refund (RF), Credit Card Number' Reversal (RV) -:redit CardaAuthorization Issued To •a=„ :" "• , fi SOUTH FLORIDA ALUMINUM PRODUCTS ' ' Received By dimonb y' - Date Paid .05/01l2008 a 65 a SITE EXPOSURE EVALUATION FORM r— -- -- -- -- -- ----------------- A I � I f j QUADRANTI 1500' I EXPOSURE I � I � I I I i —1500, I 600' I QUADRANT IV 140' I QUADRANT II I jam— 600, 600' --I i EXPOSURE A i 40' I EXPOSURE 6 600' I I I 1500' — • I I I I QUADRANT Ill I 1500, EXPOSURE B I I , I L— - — — - — — - — — - — — - — — - — — ---- -- -- -- J NOTE: ZONES ARE MEASURED FROM STRUCTURE OUTWARD SITE SCALE: 1" = 800' USING THE FOLLOWING CRITERIA, EVALUATE EACH QUADRANT AND MARK IT AS 'B', 'C', OR'D' EXPOSURE. 'C' OR'D' EXPOSURE IN ANY QUADRANT MAKE THE SITE THAT EXPOSURE. EXPOSURE C: 1. OPEN TERRAIN FOR MORE THAN 1,500 FEET.IN ANY QUADRANT. 2. ANY'C' EXPOSURE FOR GREATER THAN 600 FEET IN ANY QUADRANT: 3. NO SHORT TERM CHANGES IN 'B', 2 YEARS BEFORE SITE EVALUATION AND BUILD OUT WITHIN 3 YEARS, SITE WILL BE'B'. 4. FLAT, OPEN COUNTRY, GRASSLANDS, PONDS AND OCEAN OR SHORELINES IN ANY QUADRANT FOR GREATER THAN 1,500 FEET. EXPOSURE D: FLAT, UNOBSTRUCTED AREAS THAT ARE 1,500 FT INLAND FROM THE SHORE LINE AND ARE EXPOSED TO WIND FLOWING OVER WATER FOR A DISTANCE OF AT LEAST 1 MILE. SITE IS EXPO EVALUATED Y: _5a-trr4 %�1ca� RuWtiNv,I Psce, DATE: y 1 S d Y SIGNAT RE: LICENSE #: Luo .t �I L 'x u.�l. COF' Design Check List for Carports & Patio Covers (Page 1 of 2) 1. Design Statement: These plans have been designed in accordance with the Aluminum Structures Design Manual by Lawrence E. Bennett and are in compliance with the 2004 Florida Building Code Edition with 2006 Supplements, Chapter 20, ASM35 and The 2005 Aluminum Design Manual Part I -A & II -A and ASCE 7-02; Exposure'B'fX or'C'O or'D'_D; Enclosed Building; Importance Factor 0.87 for 100 MPH and 0.77 for 110 MPH and higher; Negative I.P.C. 0.00; 0.18 for mono -sloped roof; 0.18 for attached, fourth wall structure and gabled carports. Roof live load 10 or 30 PSF or/JtMPH for 3 second wind gust velocity load; Basic Wind Pressure:�3•e; Base design pressures areg%JPSF for Roofs and Z&V PSF for walls. Notes: Wind velocity zone and exposure category are determined by local code. "Enclosed" refers to attached covers & "open" refers to free standing mono -sloped covers. Pressures & Conversions multipliers are on page 24i & iii. II. Host Structure Adequacy Statement: I have inspected and verify that the host structure is in good repair and attachments made to the structure will be solid. (T/92 y /C I'P/�/b,�iJFIy Phone: 772-- `ill -4 913 Contractor orized IReV Name (please print) Date: Contractor / A666rized Rep* Signature �i ?3 a�•s ��� cT 4-r �T Job Name & Address Note: Projection from host structure shall not exceed 20'. III. Building Permit Application Package contains the following. Yes ; No A. Project name & address on plans EM, B. Site plan or survey with enclosure location ..................................... C. Contractor's / Designer's name, address, phone number, & signature on plans ..... LVIM D. Site exposure form completed .................................................. E. Proposed project layout drawing @ 114" scale with the following: 1. Plan view with host structure, enclosure length, projection from host structure, .. and all dimensions 2. Front and side elevation views with all dimensions & heights .................. 3. Beam; location (show in plan & elevation view) & size ........................... (Select beams from appropriate 2.1 series tables) 4. Upright location (show in plan & elevation view) & size .......... :............. (Select uprights from appropriate 2.2 series tables) (Check Table 2.3 for minimum post size) 5. Knee braces length, location, '& size (Check Table 2.3 for knee brace size) * Must have attended Engineer's Continuing Education Class within the past two years. b-5 In Design Check List for Carports & Patio Covers (Page 2 of 2) IV. Highlight details from Aluminum Structures Design Manual: Yes No A. Beam & purlin tables w/ sizes, thickness, spacing, & spans / lengths .............. (Tables 2.1.1, 2.1.2 and/or 2.1.3) Beam allowable span conversions from 120 MPH wind zone, 'B' Exposure to AM MPH wind zone and/or'C' Exposure for load width Look up span on 120 MPH table and apply the following formula: Span / Height Required Span @ 120 MPH @ j �6 MPH 0.00 (b or d) x 1.00 (b or d) x 1.00 (b or d) = 0.00 Wind Zone Exposure Multiplier** ** Multiplier Yes No B. Upright sizes, thickness, spacing, & heights / lengths (Tables 2.2.1 & 2.2.2) ....... Allowable upright height conversion from Exposure "B" for any wind zone to a "C" catagory exposure. Multiply height from table by 0.71. Also, check Table 2.3 for minimum post size To convert roof area for any wind zone from 'B' to 'C' exposure catagory, multiply by 0.71. Area from Table 2.2.1 or 2.2.2 ft.2 x 0.71 = 0.00 C. Table 2.3 w/ beam, upright, & knee braces combination, type, & size of anchors .... D. Connection details to be used such as: 1. Carport / cover plan view & section (Example Page 2-3 & 5) ................... 2. Fourth wall or mobile home connection details ................................ 3. Header to wall./ fascia (Section 7) 4. Beam to upright, wall, or another beam (pudins) ............................. . 5. Knee braces.............................................................. E. Connection to slab / footing .................................................... F. Foundation detail type & size (Table 2.4)............................ . ........... ED Notes: ** Appropriate multiplier from Table 2A or 26 on page 24i or Table 2E on page 2-iii.. b-6 General Notes and Specifications for Section 2 Tables: The structures designed for Section 2 are attached and freestanding carports and patio covers. Freestanding carports are considered to be open structures w/ a negative internal pressure coefficient of 0.00. Attached carports & covers, structures with a fourth wall, and gabled carports are considered to be enclosed structures w/ a negative internal pressure coefficient of 0.18. The design wind loads used are from ASCE 7-02 Section 6.5, Analytical Procedure and are in compliance with the 2004 Florida Building Code w/ 2006 Supplements or larger of combined loading or wind loading. The loads assume a mean roof height of less than 30; roof slope 0° to 25' (+/-10°) for attached structures or gabled free standing carports and 0° to 10' for freestanding covers; For all carports, patio covers, and utility sheds I = 0.87 for 100 MPH zone, I = 0.77 for 110 MPH and higher zones. All pressures shown in the table below are in PSF (#/SF). All framing components are considered to be 6063-T6 alloy. For components of 6005-T5"and 6061-T6 multiply spans by 1.13. Section 2 Design Loads for Attached & Freestanding Covers and Utility Sheds Wind Zone MPH Basic Wind Pressure Roofs (#/SF) Components & Cladding Freestanding Carports .w/ Monosloped Roofs Attached Carports or Gabled Freestanding Carports Utility Sheds Overhang / Cantilever Posts / Uprights Utility Shed & Walls &Roofs Cantilever 50 10 50 20 10 100 13.0 15.8 16.6 26.6 46.8 12.0 23 27 1 30 27 38 45 110 14.0 15.6 17.7 26.8 47.1 11.4 27 32 36 33 46 55 120 17.0 16.2 21.1 27.4 48.3 13.5 32 39 43 39 54 65 123 18.0 16.3 22.2 28.9 1 50.8 14.2 34 41 45 41 57 69 130 20.0 16.8 24.8 32.2 56.6 15.9 38 45 51 46 64 77 1404 23.0 18.4 28.7 37.3 65.7 1 44 53 59 53 74 89 140-2 23.0 32.4 30.9 37.3 65.7 18.4 44 53 59 54 74 89 150 26.0 33.1 33.0 42.8 75.4 1 16.9 51 60 68 61 85 102 Notes: 1. Roof and framing members of carports & patio covers are considered to be the main frame resistance components. To convert the above loads to "C" and "D" exposure loads see Table 2E next page. Table 2A Conversion Factors for Table 21B Conversion Factors for Section 2 Roof Beam Spans Section 2 Roof Beam Spans for Freestanding Carports* w/ Monosloped Roofs for Attached. Carports or Gabled Freestanding Carports From 120 MPH Wind Zone to others: exposure "a" From 120 MPH Wind Zone to others; exposure "B" Wind Zone (MPH) Applied Load (#/Sq. Ft)' Deflection (d) Bending (b) 100 15.8 1.01 1.01 110 15.6 1.01 1.02 120 16.2 1.00 1.00 123 1 16.3 1.00 0.99 130 16.8 0.99 0.98 140-1 18.4 0.96 0.94 140-2 32.4 0.79 0.71 150 33.1 0.79 0.70 * For Freestanding Carports with Gabled Roofs use Conversion Table 2B Table 2C Conversion Factors for Section 2 for Enclosed Shed Walls From 120 MPH Wind Zone to others; exposure "B" Wind Zone (MPH) Applied Load (#/Sq. Ft) Deflection (d) Bending (b) 100 26.6 1.01 1.01 110 26.8 1.01 1.01 120 27.4 1.00 1.00 123 28.9 0.98 0.97 130 32.2 0.95 0.92 1404 37.3 0.90 0.86 140-2 37.3 0.90 0.86 150 42.8 0.86 0.80 Continued next page... 2-ii Wind Zone (MPH) Applied Load (#/Sq. Ft) Deflection (d) Bending (b) 100 16.6 1.08 1.13 110 17.7 1.06 1.09 120 21.1 1.00 1.00 123 22.2 0.98 0.97 130 24.8 0.95 0.92 1404 28.7 0.90 0.86 140-2 30.9 0.88 0.83 150 33.0 0.86 0.80 Table 2D Conversion Factors for Section 2 Roof Beam Spans for Overhang / Cantilever (All Building Types) From 120 MPH Wind Zone to others; exposure "B" Wind Zone (MPH) Applied Load (#/Sq. FL) Deflection (d) Bending (b) 100 46.8 1.01 1.02 110 47.1 1.01 1.01 120 48.3 1.00 1.00 123 1 50.8 0.98 0.97 130 56.6 0.95 0.92 1404 65.7 0.90 0.86 140-2 65.7 0.90 0.86 150 75.4 0.86 0.80 _ SECTION 2 ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS EXISTING HOST STRUCTURE FOURTH WALL FRAME (IF REQUIRED) CROSS BEAM ANCHOR WITH HEADER CHANNEL (SEE ROOF CONNECTION DETAILS SECTION 7) FRONT WALL BEAM (SELECT'L FROM BEAM SPAN TABLES FOR ATTACHED COVERS) MID SPAN BEAM (SELECT'L' FROM BEAM SPAN TABLES FOR ATTACHED COVERS) SELECT BEAM (SEE BEAM SPAN TABLES FOR ATTACHED COVERS) POST SHADING TYPE II (SEE TABLE 2.2.1 AND / OR TABLE 2.2.2) SHADING TYPE I (SEE TABLE 2.2.1 AND / OR TABLE 2.2.2) DOUBLE CARPORT WITHOUT CENTER POST PLAN VIEW 3" RECEIVING CHANNEL ANCHORS W/ (3) EACH #8 S.M.S. @ 12" O.C. (SEE ROOF CONNECTION DETAILS SECTION 7) HOST STRUCTURE WALL _ I OR FASCIA I FOURTH WALL FRAME (IF REQUIRED) SCALE: 3/16" = V-0" PROJECTION VARIES MID -SPAN BEAM (SEE BEAM SPAN TABLES FOR ATTACHED COVERS) ROOF PANELS (SEE TABLES SECTION 7) o� POST TO BEAM (SELECT FROM TABLE 2.3) POST SIZE AND SPACING (SEE TABLE 2.2.1 AND / OR 2.2.2) SEE FOOTING DETAILS PAGE 2-25 DOUBLE CARPORT WITHOUT CENTER POST {ELEVATION VIEW SCALE: 3/16" V-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL & STRUCTURAL ENGINEERING P.O. Box 214368, South Daytona, FI 32121 Telephone #: (386) 767-4774 Fax #: (386) 767-6&% Email: lebpe@bellsouth.net PAGE @ COPYRIGHT2006 2-2 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT. P.E. ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS SECTION 2 SELECT BEAM FROM BEAM SPAN TABLES FOR ATTACHED KNEE BRACE (REQUIRED) COVERS 2" x 3" x 0.050" SEE BEAM SPAN TABLES FOR SPAN ATTACHED COVERS WITH (AFTER COMPUTING POST ADDED "A" FROM PAGE 2-1, 2-2 OR 2-3) ALTERNATE KNEE BRACE LOCATED AT FRONT WALL CROSS BEAM (SEE TABLE PREVIOUS PAGE) POST SIZE (SEE TABLE 2.2.1, 2.2.2 AND I OR TABLE 2.3) AY OR DOUBLE BAY CARPORT FOURTH WALL.FRAME SCALE: 3M6" =1`-0" Lawrence E. Bennett, P.E. FL # 16W CIVIL & STRUCTURAL ENGINEERING P:O. Box 214368. South Daytona, FI 32121 Telephone #: (386) 767-4774 Fax #: (386) 767-6556 Email: lebpe@bellsouth.net PAGE © COPYRIGHT 2006 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. 2-9 I SECTION 2 I ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS ------------------------------- PAN OR COMPOSITE PANEL ROOF BEAM 1 CONNECTION = i START OR END KNEE BRACE OF BEAM SPAN CENTER OF BRACE 2" x 3" x 0.050" MINIMUM KNEE BRACE (SEE TABLE 2.3) KNEE BRACE REQUIRED IF POST NOT SET IN CONCRETE FOOTING KNEE BRACE NOT REQUIRED FOR ATTACHED STRUCTURES COLUMN ® CONNECT KNEE BRACE TO COLUMN AND BEAM WITH ® 0.050"'U' CHANNEL,'H' ® CHANNEL, OR GUSSET PLATE, FASTEN WITH S.M.S. AT EACH CONNECTION POINT PER TABLE 2.3 KNEE BRACE TO POST DETAIL - BEAM PARALLEL TO ROOF SCALE: 3" = V-0" i Lawrence E. Bennett, P.E. FL # 16644 CIVIL & STRUCTURAL ENGINEERING " wvs-n 0 Py P.O. Box 214368, South Daytona, FI 32121 10 t: Telephone #: (386) 767-4774 Fax #: (386) 767-6556 Email: lebpe@bellsouthnet FIL PAGE © COPYRIGHT2006 2.14 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. SECTION 2 1 ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS —i---------- t W ROOF PANEL _ (SEE SECTION 7) ANCHOR PER DETAIL FOR PAN OR COMPOSITE PANEL BEAMS MAY BE ANGLED FOR FOR NUMBER OF BOLTS AND GABLED FRAME - SIZE OF POST (SEE TABLE 2.3) COLUMN NOTCHED TO SUIT � BEAM AND POST SIZES (SEE TABLES SECTION 2) 'IDE NOTCH POST TO BEAM CONNECTION SCALE: 3" = V-0" BEAMS MAY BE ANGLED FOR — -- — — — — — — — — — — GABLED FRAME to Lu ROOF PANEL _ (SEE SECTION 7) 1-3/4" x 1-3/4" x 0.063" — — — — — — — — — — RECEIVING CHANNEL THRU L ANCHOR PER DETAIL FOR PAN BOLTED TO POST'W/ THRU OR COMPOSITE PANEL BOLTS FOR SIDE BEAM (SEE TABLE 2.3 FOR NUMBER FOR NUMBER OF BOLTS AND OF BOLTS) I - SIZE OF POST (SEE TABLE 2.3) � 0 - - — BEAM AND POST SIZES (SEE TABLES SECTION 2) COLUMN NOTCHED TO SUIT, CENTER NOTCH POST TO BEAM CONNECTIO SCALE: 3" = V-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL & STRUCTURAL ENGINEERING P.O. Box 214368, South Daytona, FI 32121 Telephone #. (386) 767-4774 Fax #: (3B6) 767-6556 Email: lebpe@bellsouth.net PAGE © COPYRIGHT2006 2-16 NOT TO:BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. I ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS CONNECTOR MAY BE (2) ANGLES, INTERNALLU' CHANNEL OR EXTERNALLU' CHANNEL EACH SIDE OF CONNECTING BEAM W/ SCREWS (PER SECTION 9) PRIMARY / FRAMING BEAM (SEE SPAN TABLES - SECTION 2) MINIMUM NUMBER S.M.S. 3/4" LONG REQUIRED EQUAL TO BEAM DEPTH (SEE SECTION 9) HOST STRUCTURE MASONRY OR FRAMED WALL (SELECT FASTENERS FROM w T • o_� w- SECTION 2 EXTRUSIONS W/ INTERNAL SCREW BOSSES MAY BE CONNECTED W/ (4) #10 x 1-1/2" INTERNALLY SECONDARY BEAM / PURLINS(SEE SPAN TABLES SECTION 2) BEAM TO WALL CONNECTION: (2) 2" x 2" x 0.060" EXTERNALLY MOUNTED ANGLES ATTACHED TO WOOD FRAME WALL W/ MIN. (2) 3/8" x 2" LAG SCREWS PER SIDE OR TO CONCRETE W/ (2)1/4" x 2-1/4" ANCHORS OR. MASONRY WALL ADD (1) ANCHOR PER SIDE FOR EACH INCH OF BEAM DEPTH LARGER THAN 3" SECTION 9 TABLES) a ® ALTERNATE CONNECTION: ® (1) 1-3/4" x 1-3/4" x 1-3/4"^x 1/8" ® INTERNAL U-CHANNEL ATTACHED TO WOOD FRAME PRIMARY BEAM WALL W/ MIN. (3) 3/8" x 2" LAG (SEE SPAN TABLES_ SCREWS OR TO CONCRETE SECTION 2) OR MASONRY WALL W/ (3)1/4" ANGLE OR RECEIVING x 2-1/4" ANCHORS. OR ADD (1) CHANNEL ANCHOR PER SIDE FOR EACH INCH OF BEAM DEPTH LARGER THAN 3" BEAKTO WALL CONNECTION DETAIL SCALE: 3" = 1'-.0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL & STRUCTURAL ENGINEERING P.O. Box 214368, South Daytona, Fl 32121 Py Telephone #: (386) 7674774 Fax #: (386) 767.6&% Email: febpe@bellsouth.net I © CO&RIGHIP " _ I PAGE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. 2- 1,/ 9 ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS I SECTION 2 ATTACHMENT DETAILS SHOWN REQUIRE DIAGONAL w Ig z ALUMINUM /STEEL COLUMN BRACING FOR j FREE-STANDING COVERS N INTERNAL EXTRUDED ALUMINUM BASE OR BREAK CORROSION RESISTIVE STEEL P — FORMED U-CLIP THRU BOLT PER SCHEDULE ` (4) MAX. 1/4" X 2-1/2" WEDGE CONCRETE SLAB OR FOOTING BOLT OR EQ. (SEE TABLE BELOW FOR NUMBER OF TYPE I POST TO CONCRETE CONNECTION TUBE COLUMN BASE SCHEMATIC INTERNAL BASE SCALE: 3" = V-0" ATTACHMENT DETAILS SHOWN REQUIRE DIAGONAL BRACING FOR FREE-STANDING COVERS IRROSION RESISTIVE STEEL THRU BOLT PER SCHEDULE ALUMINUM / STEEL COLUMN EXTERNAL BREAK FORMED ALUMINUM BASE OR BREAK FORMED U-CLIP ` (8) MAX. 1/4" X 2-1/2" WEDGE CONCRETE SLAB OR FOOTING BOLT OR EQ. (SEE TABLE BELOW FOR NUMBER OF BOLTS) TYPE II POST TO CONCRETE CONNECTION BREAK FORMED COLUMN BASE SCHEMATIC EXTERNAL BASE SCALE: 3" = V-0" * FOR POST TO -WOOD DECK (MIN. 2" NOMINAL LUMBER) USE THESE DETAILS W/ WOOD FASTENERS. NOTE: ALL BASE PLATES SHALL BE A MINIMUM OF 2-1/8" IN HEIGHT AND SHALL BE 0.125" 6063 T-6 EXTRUDED ALLOY OR 0.125" 5052 H-32 BREAK FORMED ALLOY Number of Wedge Bolts (POWERS or Equal for Super Base Connection Wind Zone (MPH) Wind Uplift (PSF) Post Spacing INumber of Fasteners 8'-0" 10%0" 12,-0" 14%0" 16%0" 18'-0" 20'-0" 100, 16.6 2 2 3 3 4 4 5' 110 17.7 2 2. 3 `3 4 4 5' 120 21.1 2 3 3 4 5' 5' 6' 123 22.2 2 3 4 4 5' 5' 6' 130 24.8 3 3 4 5` 5' 6` 7` 1404&2 28.7 3 4 5' 5* 6 . 7' . 8 ` - 150= 33.0 . 4 5• 5` 6• 7• 8' 9" For connections that require more than (4) fasteners use type II base.** For connections that require more than eight bolts use the "Super Base' Note: Allowable load on 1/4" x 2-1/2" Wedge Bolt or Equiv. @ 5d is 878#. Example for Base Connection: # of anchors = area over post' applied load + allowable load on anchor For a 30' x 16' carport with Z overhang in a 120 MPH wind zone, 'B" exposure the load width on the front wall is: 16' + 2 + 2' =10', assume posts are at 10' O.C. then area =100 SF and the applied load is 21.1 PS x 100 SF = 2110# for a 3"x3"4.060" post from Section 9 tables: Allowable load for wedge bolts 878# each, 2110# + 878# = 2.4 so use (3) wedge bolts REVISED APRIL 2007 Lawrence E. Bennett, P.E. FL # 16644 CIVIL & STRUCTURAL ENGINEERING P.O. Box 214368, South Daytona, FI 32121 Telephone #: (386) 767-4774 Fax M (386) 767-6556 Email: lebpe@bellsouth.net © COPYRIGHT 2006 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. PAGE 2-21 ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS I SECTION 2 1" PER FT. MAX. FOR 3-1/2" (4" NOMINAL) 2'-0" MIN. ALL SLABS BEFORE SLOPE TYPE FLAT SLOPE / NO FOOTING 0-2" / 12" (1) #50 BAR CONT. � a wCD—�—'— d 00 ' E 1'� V '. 8" TYPE II MODERATE SLOPE FOOTING 2" / 12"-1'-10" (1) #50 BAR CONT. a � ANGLE 33° TO 45° 12" TYPE III STEEP SLOPE FOOTING > 1'-10" Notes: 1. The foundations shown are based on a minimum soil bearing pressure of 1,500 psf. Bearing capacity of soil shall be verified, prior to placing the slab, by field soil test (soil penetrometer) or a soil testing lab. 2. The slab / foundation shall be cleared of debris, roots, and compacted prior to placement of concrete. 3. No footing other than 3-1/2" (4" nominal) slab is required except when addressing erosion until the projection from the host structure of the carport or patio cover exceeds 20'-0". Then a minimum of a Type II footing is required. All slabs shall be 3-1/2" (4" nominal) thick. 4. For wood frame'utility sheds the minimum depth of the footing shall be 10" for Type II footing and 14" for Type III footing with 6" Min. exposed above grade. 5. Monolithic slabs and footings shall be minimum 2,500 psi concrete with 6 x 6 -10 x 10 welded wire mesh or crack control fiber mesh: Fibenmesh @ Mesh; InForceTm e3TM (Formerly Fibermesh MD) per maufacturer's specification may be used in lieu of wire mesh. All slabs shall be allowed to cure 7 days before installing anchors. 6. If local building codes require a minimum footing use Type II footing or footing section required by local code. Local code governs. SLAB -FOOTING DETAILS SCALE: 314" = V-0" Lawrence E. Bennett, P.E. FL # 16644 qw C 0 Py CIVIL & STRUCTURAL ENGINEERING P.O. Box 214368, South Daytona, F132121 F mi Lmt:Telephone #: (386) 767-4774 Fax #: (386) 767.6556 Email: lebpe@bellsouth.net © COPYRIGHT2006 PAGE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. 1 2-25 SECTION 2 I ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS Table 2.1.2-140-1 Allowable Roof Beam Spans For Attached Covers, Fourth Wall Structures, or Freestanding Gabled Carports For 3 sec. wind gust at 140-1 MPH; using design load of 28.7 #/SF (65.7 #/SF for Max. Cantilever) Aluminum Allov 6063 T-6 2" x 3" x 0.045" Hollow 2" x 3" x 0.050" Hollow Tilt Load Width (ft.) Max. Span 17(bending'b'ordeflection 'dj Load Width (ft.) Max. Span 'L'/(bending'b'ordeflection'd') 1&2 Span 3 Span 4 Span Cant lever 1&2 Span 3 Span 4 Span Can lever 4 5'-10" d 6'-10" b 6'-7" b 1'-4" d 4 5'-9" d 6'-8" b 6'-5" b 1 1'-4" d 5 T-5" d 6'-1" b 5'-11" b 1'-3" d 5 64" b 5'-11" b &-9" b 1'-2" d 6 4'-11" b 5'-7" b 5'-5" b 1'-2" d 6 4'-10" b 5'-5" b 5'-3" b 1'-2" d 7 4'-7" b 5'-2" b 4'-11" b 1'-1" d 7 4'-6" b 5'-0" b 4'-10" b 1'-1" d 8 4'-4" b 4'-10" b 4'-8" b 1'-1" d 8 4'-2" b 4'-8" b 4'-7" b 1'-0" d 9 4'-1" b 4'-7" b 4'-5" b 1'-0" d 9 T-11" b 4'-5" b 4'4' b 0'-11" d 10 T-10" b 4'-4" b 4'-2" b 0'-11" d 10 T-9" b 4'-1" b 0'-11" d 11 T-8" b 4'-1" b T-11" b 0'-11" d 11 3'-7" b MIT-9" T-10" b 0'-11" d 12 3'-0" b 3'-11" b 3'-10" ti 0'-11" d 12 3'-5" b b 0'-11" d 2" x 4" x 0.045" Hollow Tilt 2" x 4" x 0.044" x 0.100" Self Mating Beam Load Width (ft.) Max. Span 'L'/(bending'b' or deflection 'dj Load Width (ft.) Max. Span'L'/(bending 'b' or deflection 'd') 1&2 Span 3 Span 4 Span Cana ever 1&2 Span 3 Span 4 Span Can lever 4 T-2" b 7'-11" b T-9" b 1'-8" d 1 4 8'-0" b 8'-11" b 8'-8" b 1'-11" d 5 6'-5" b T-2" b 6'-11" b 1'-6" d 5 T-2" b 8'-0" b T-9" b 1'-9" d 6 5'-10" b 6'-6" b 6'-4" b 1'-5" d 6 6W" b T-4" b T-1" b 1'-8" d 7 5'-5" b 6'-0" b 5'-10" b 1'4" d 7 V-1" b 6'-9" b 6W" b 1'-7" d 8 5'-1" b 5'-8" b 5'-6" b 1'4" d 8 5'-8" b 6'-4" b 6'-2" b 1'-6" d 9 4'-9" b 5'-4" b 5'-2" b 1'-3" d 9 5'4" b 5'-11" b 5'-9" b 1'-5" d 10 4'-6" b 5'-1" b 4'-11" b 1'-2" d 10 5'-1" b 1 5'-8" b 1 5'-6" b 1'-5" d 11 4'4" b 1 4'-10" b 4'-8" b 1 1'-2" d 11 C-10" b 5'-5" b 1 5'-3" b 1'-4" d 12 4'-2" b 1 4'-7" b 4'-0" b 1 1'-2" d 12 b - 5'-0" b 1'-4" d 2" x 5" x 0.050" x 0.100" Self Mating Beam 1 2" x 6" x 0.050" x 0.120" Self Mating Bea Load Width (ft.) Max. Span 'L'/(bending'b' or deflection'd1 Load Width (ft.) Max. Span'LI(bending'b' or deflection'dj 1&2 Span 3 Span 4 Span Cant lever 1&2 Span 3 Span 4 Span Cant lever 4 9'-10" b 11'-0" b 10'-8" b 2'-4" d (4j 11'-0" b 12'4" b 11'-11" b 2'-9" d 5 8'-10" b 9'-10" b 9'-6" b 2'-2" d 5 97- 0 11'-0" b' 10'-8" b 2'-T' d 6 8'-0" b 8'-11" b 8'-8" b 2'-1" d 6 8'-11" b 10'-1" b 9'4' b 2'-5" d 7 T-5" b 8'-4" b 8'4" b 1'-11" d 7 8'-4" b 9'4" b. 8'-11" b 2'-4" d 8 6'-11" b T-9" b T-6" b 1'-10" d 8 T-9" b 8'-9" b 8'-5" b 2'-2" d 9 6' 7" b T-4" b T-1" b 1-10" d 9 T-4" b 8'-3". b T-11" b T-1" d 10 6'-3" b 6'-11" b 6'-9" b 1'-9" d 10 6'-11" b 7'-9" b 7'-0" b 2'-0" d 11 5'-11" b 6'-8" b 6'-5" b 1'-8" d 11, 6'-8" li 7'-5" b 1 7'-2" b 1'-11" d 12 5'-8" b 6'-4" b V-2" b 1'-0" d 12 6=4" b 7'-1" - b 1 6'-10" b : l'-11" d Gabled sloped roofs include gables with a roof slope greater than 1" in 12". Notes: 1. Above spans do not include length of knee brace. Add horizontal distance from upright to center of Brace to beam connection to the above spans for total beam spans. 2. Spans may be interpolated. Lawrence E. Bennett, P.E. FL # 16644 CIVIL & STRUCTURAL ENGINEERING P.O. Box 214368, South Daytona, FI 32121 Telephone #: (386) 767-4774 Fax #: (386) 767.6556 Email: lebpe@bellsouth.net PAGE @ COPYRIGHT2006 2-48 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. N 00 T n M m O 17- f n m < :3 a Qo CD #MC/) m m x y 3 m N C V W (D 0 CD o xxm-0 Z Ill ~ N m 1l m r- Fes.: :ss Table 2.1.4-140-1 Allowable Spans For Miscellaneous Framing Beams Used In Attached Covers, Fourth Wall Structures, or Freestanding Gabled Carports Aluminum Alloy 6063 T-6 For 3 second wind gust at 140-1 MPH velocity; using design load of 28.7 #/SF Single Self -Mating Tribute Load Width Beams 6'-0" 7'•0" 8'-0" 9'-0" 10'.0.. 11'-0"J 1 12'-0" 1 13'-0" 1 14'-0" 1 15'-0" 1 16'-0" 1 17'-0" Allowable Span'L' / bending'b' or deflection'd' 2" x 6" x 0.050" x 0.120" 2" x 7" x 0.055" x 0.120" 2" x 8" x 0.072" x 0.224" 2" x 9" x 0.072" x 0.224" 2" x 9" x 0.082" x 0.306" 2" x 10" x 0.092" x 0.389" 8'-11" b 9'-9" b 14'4' b 1 '- " b 17'-8" d 20'-8" d 8'-4" b 9'-0" b 13'-5" b 14'-1" b 16'- " ti 19'-8' d 7'4" b 8'-5" b 12'-7" b 1'-2" b 15'- " b 18'-8 b T-4" b T-11" b 11--10" b 12'-5" b 14'-6" b 17'-8" b 6-11" bi T-7" b 11'4" b 11'-9" b 137-9" b 16'-9" b 6'-8" b 7'-2" b 10'-8" b 11'-3" b 13'-1" b 15'-11" b 6'-4" bj 6'-11" b 10'-3" b 10'-9" b 12'-7" b 15'-3" b 6'-1" b 6'-7" b 9'-10" b 10'-4" b 12'-1" b 14'-8" b 5'-11" b 6'-5" b 9'-6" b 9'-11" b 11'-8" b 14'-2" b T-8" b 6'-2" b 9'-2" b 9'-7" b 11'-3" b 13'-8" b 5'-6" b 5'-11" b 8'-11" b 9'-4" b 10'-11" b 13'-3" b 64- b 5'-9" b 8'-7" b 9'-0" b 10'-7" b 12'-10" b Double Self -Mating Beams Tributary Load Width 6'.0" 1 7'-0" 8'-0" 1 9'-0" 10'-0" 1 11'-0" 1 12'-0" 1 13'.0" 1 14'.0" 1 15'40" 16'-0" 17'-0" Allowable Span 'L' / bending'b' or deflectlon'd' 2" x 8" x 0.072" x 0.224" 2" x 9" x 0.072" x 0.224" 19'-1" dl 20'-11" d 18'-1" d 19'-11" d 17'-4" d 18'-8" b 16'-8" d 1T-7" b 15'-11" b 16'-8" b 15'-2" b 15'-11" bi 14'-6" b 15'-3" bl 137-11" b 14'-7" bj 13'-5" b 14'-1" b 1--11" b 13'-7" b 12'-7" b 13'-2" b 12'-2" b 12'-9" b 2" x 9" x 0.082" x 0.306" 22'-3" d 21'-2" d 20'-3" d 19'-5" d 18'-9" d 18'-2" di 17'-8" d 17'-1" b 16'-5" b 15'-11" b 15'-5" b 14'-11" b 2"_x 10" x 0.092" x 0.369" 25'-9" d 24'-5" d 23'-4" d 22-6" d 21'-8" d 21'-0" d 20'-5" d 19'-11" d 19'-5" d 18'-11" d 18'-7" b uaDiea siopea roors include gables with a roof slope greater than 1" in 12". Note: 1. It is recommended that the engineer be consulted on any carrier beam that spans more than 35' 2. Spans are based on 140-1 M.P.H. wind load plus dead load for framing. 3. Span Is measured from center of connection to fascia or wall connection. 4. Above spans do not Include'length of knee brace. Add horizontal distance from upright to center of brace to beam connection to the above spans for total beam spans. 5. Spans maybe interpolated. 1T1- q Z N ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS I SECTION 2 Table 2.2.2 Allowable Attributable Roof Area per Post for Carports & Patio Covers ALUMINUM POSTS Aluminum Post Wind Load (MPH) = 100 1 110 1 120 1 123 1 130 140-1&2 150 16.6 #/SF 117.7 #/SF 1 21.1 1 22.2#/SF 1 24.8 #/SF F 1 32.99 #/SF Maximum Allowable Roof Area in Square Feet for Various Loads on Post Height Load (lbs.) 3" x 3" x 0.090" Hollow Extrusion -Aluminum Alloy 6063 T-6 11'-10" 5,184 432 455 384 365 365 326 307 13'-10" 3,888 324 341 288 1 4 274 2 5 1 230 15'40" 3,024 252 265 224 1 213 213 1 1 190 1 179 17'-10" 2,268 189 199 168 1 160 160 143 1 134 Height Load (lbs.) 3" x 3" x 0.125" Hollow Extrusion -Aluminum Alloy 6063 T-6 13'-9" 6,912 576 606 512 487 487 435 409 16'4" 5,184 432 455 384 365 365 1 326 307 18'.4" 4,032 336 354 299 284 284 254 239 20'-7" 3,024 252 265 224 213 213 190 179 Height Load (lbs.) 4" x 4" x 0.125" Hollow Extrusion -Aluminum Alloy 6063 T-6 15'-9" 9,312 776 817 690 656 656 586 551 18'-5" 6,984 582 1 613 1 517 492 492 439 1 413 21'-0" 5,432 453 476 402 383 383 342 1 321 23'-8" 4,074 1 340 357 302 287 287 256 1 241 Steel Post Wind Load (MPH) = 100 1 110 120 123 1 130 1 1404&2 150 16.6 #/SF 117.7 #/SF 21.1 22.2#/SF 1 24.8 #/SF 1 28.7 #/SF 32.99 #/SF Maximum Allowable Roof Area in Square Feet for Various Loads on Post Height Load (lbs.) 3" x 3" x 14 Gauge Post - 46 k.s.i. Steel 19'40" 10,050 838 882 744 708 632 546 595 21'.9" 7,430 619 652 550 523 1 467 1 404 440 23'-9" 5,638 470 495 418 397 355 1 306 334 25'-9" 4,371 364 1 383 1 324 308 275 1 238 259 Height Load (lbs.) 3" x 3" x 11 Gauge Post - 46 k.s.i. Steel 191-8" 15,870 1323 1392 1176 1118 998 863 939 21'-7" 11,730 978 1029 869 826 738 638 694 23'-6" 8,970 748 787 664 632 1 564 1 488 531 25'-0" 6,900 575 1 605 511 486 434 1 375 408 ' Height Load (lbs.) 4" x 4" x 14 Gauge Post - 46 k.s.i. Steel 26'-8" 12,650 1054 1110 937 891 796 688 749 29'3" 9,350 1 779 1 820 693 1 658 588 508 553 32'-0" 1 7,150 1 596 627 1 530 1 504 450 389 1 1 423 34'-8" 1 5,500 1 458 482 407 1 . 387 346 299 1 325 Conversion Multipliers for Freestanding Carports with Mono Sloped Roofs Example: Find Roof Area Needed; Area = W; Post Spacing ='S'; Structure Projection ='W A = S x (W/2 + O.H.); If'S' = 20', W = 24', and O.H. = 2' then: 'Area' = 280 Sq. Ft a. For a 13'-10" post and 120 m.p.h. wind load of 14 # / Sq. Ft post choices are: 1. 3" x 3" x 0.125" Hollow Extrusion 2. All post sizes listed below the 3" x 3" x 0125" Hollow Section b. If job conditions dictate a post hieght of 20'-7" for A = 280 Sq. Ft and 120 MPH wind zone, then a 3" x 3" x 0.125" Hollow Extrusion can NOT be used since it can only support a roof area of 216 Sq. Ft Thus, design must satisfy both height and area requirements. 100 110 120 123 130 1404 140 2 150 1.00 1.20 1.27 1.25 1.23 1.27 1.23 1.23 Note: 1. Spans may be interpolated. 2. For freestanding covers, multiply above roof areas by 1.25 (except for 100 MPH). Lawrence E. Bennett, P.E. FL # 16W CIVIL & STRUCTURAL ENGINEERING. P.O. Box 214368, South Daytona, FI 32121 Telephone #: (386) 767-3774 Fax #: (386) 767.6556 Email: lebpe@bellsouth.net © COPYRIGHT2006 I PAGE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. 1 2-61 tv N T D M m O 0 0 9 z 0 Table 2.3 Schedule of Post to Beam Size and Number of Thru-Bolts Possible w/ Min. Edge Distance of 2-1/2d Aluminum Alloy 6063 T-6 Beam Minimum Min. # Thru-Bolts Min, # ThrEd Miminum # Size Post Size @ Beam (e) @ Post Minimum Knee Brace Knee Brace' Screws*** 3/8" 1/2" 1/4" 5116" Hollow Sections 2" x 2' x 0.044" cross N/A Beam N/A** N/A" N/A" N/A" N/A" N/A*' N/A'* N/A" 2" X 2" 3 2" x 3" x 0.050" Hollow Tilt 2" x 2" x 0.044" or 5 3 3 2 3 2 1 1 2" x 3" x 0,050" 3 2" x 2" x 0.045" Snap 2" x 4" x 0.05011 Hollow 2" x 3" x 0.04511 Hollow or 7 5 4 3 5 3 3 3 2" x 3" x 0.045" Snap- 2" x 3" x 0.050" 3 Self Mating Beams . 2" x 4" x 0.038" X 0.10011 3" x 3"x 0.06011 Scalloped 5 4 2 2 5 3 3 2 2" x 3" x 0.050" 3 2" x 5" 0.050" X 0.100" 3" x 3"x 0.060" Scalloped 7 5 3 3 5 3 3 2 2" x 3" x 0.050" 3 " x 6" x 0.050" X 0.120" 3" x Wx 0.060" Scalloped 8 6 3 C33 I 5 3 3 2" x 3" x 0.050" 3 2" x 7" x 0.055" x 0.120" 3" x 3" x 0.093" 10 7 4 4 5 3 3 2 2" x 4" x 0.050" 3 2" x 8" x 0.072" x 0.224" 3" x 3" x 0.093" 11 9 5 5 5 3 3 2 2" x 4" x 0.050" 3 2" x 9" x'0.072" x 0.224" 3" x 3" x 0.125" 13 10 6 6 5 3 3 2 2" x 4" 70.05011 3 2" x 9" x 0.082" x 0.306" 4" x 4" x 0.125" 13 11 6 6 7 5 4 3 2" x 4" x 0.050" 3 2" x 10" x 0.092" x 0.369" 4" x 4" x 0.125" 1 15 15 r 7 7 19 5 4 3 2" x 4" x 0.050" 4 ' Minimum post/beam may be used as minimum knee brace '* Fasten external screws or clips. See Details "*For screw size see wind zone chart The minimum size and spacing of stitching screws shall be the same as table 3A.3. Knee Brace Min. Length 'Max. Length 2" x 2" x 0.044" 1'-4" 2'-0" 2" x 2" x 0.055" V-4" 2'-0" 2" x 2" x 0.093" 1'-4" 2'-0" 2" x 3" x 0.050" 1'-6" 2'-6" 2" x 4" x 0.050" 11-6" 3'-0" Example: Number of bolts required for 120 MPH, "B" exposure, Attached (Enclosed) structure; MWFRS Design Load 14 PSF load width of post = 12', post spacing = 10', w2 = 14 PSF Post Uplift = 12' x 10' x 14' = 1680# From Table 9.4A* use wall thickness of lesser member Example: use Twall = 0.60" Allowable Loads # Bolts Req'd * @ post base @ beam 1/4" = 468# / bolt 3.52 use 4 yes yes 5/16" = 610 # / bolt 2.75 use 3 yes yes 3/8" = 731# / bolt 2.29 use 3 yes yes 112" = 1,004 # / bolt 1.67 use 2 yes yes - i nese vawes are gooa Tor post base & beam bolts CO) M --1 O Z N SOLID ROOF PANEL PRODUCTS U) W INDUSTRY STANDARD ROOF PANELS I.- 12.00" 12" WIDE x VARIOUS HEIGHT RISER ROOF PANEL SCALE: 3" = V-0" im- 0 q 12.00" 12" WIDE x 3" RISER INTERLOCKING ROOF PANEL SELECT PANEL DEPTH FROM TABLES (9) COPYRIGHT 2006 SCALE: 3" = V-0" 12.00" CLEATED ROOF PANEL SECTION 7 = V-0" I ALUMINUM SKIN E.P.S. CORE �k . . ........................ .................. .......................... .... I ................. ... . .......... . .......... ......... . ....................... SID. CONNECTIONS VARY za- ................... ........................ 0 OT I ....... (DO OT AFFECT SPANS) .................... ........................ ............ ......... ...................... 48.00" COMPOSITE ROOF PANEL [INDUSTRY STANDARD] SCALE: 3"'= i'-06' Lawrence E. Bennett, P.E. FL # 16644 CIVIL & STRUCTURAL ENGINEERING P.O. Box 214368, South Daytona, Fl 32121 Telephone #: (386) 767-4774 Fax #: (386) 767-6556 Email: lebpe@belfsouth.net NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. PAGE 7-1' SECTION 7 1 SOLID ROOF PANEL PRODUCTS EXISTING TRUSS OR RAFTER 6" x T x 6" 0.024" MIN. BREAK FORMED FLASHING ROOF PANEL* -------------- (2) #10 x 1-1/2" S.M.S. OR ._:.::::::::... WOOD SCREW PER RAFTER .: �. ........�. r ............... co z-n . .......: w OR TRUSS TAIL ¢.w.. ................................... ALTERNATE: #10 x 3/4" S.M.S. OR WOOD —� SCREW SPACED @ 12" O.C. EXISTING FASCIA SCREW #10 x ('T + 1/2") W/ 1-1/4" FENDER WASHER * FOR FASTENING TO ALUMINUM USE TRUFAST I POST AND BEAM (PER HD x ("t" + 3/4") AT 8" O.C. FOR UP TO 130 MPH TABLES) WIND SPEED "D" EXPOSURE; 6" O.C. ABOVE 130 MPH AND UP TO A 150 MPH WIND SPEED 1 "D" EXPOSURE. ALTERNATE MOBILE HOME FLASHING: - FOR FOURTH WALL CONSTRUCTION COMPOSITE ROOF PANELS SCALE: 3" = V-0" INSTALLATION INSTRUCTIONS: A. PLACE (2) BEADS OF CAULKING ON BACK SIDE OF HEADER BEFORE INSTALLING. B. SLIDE 1" TAB AT,TOP OF HEADER UNDER DRIP EDGE. DO NOT PUSH DRIP EDGE UP. DRIP EDGE MUST MAINTAIN SAME PLANE AS SLOPE,OF ROOF. C. FASTEN HEADER TO FASCIA BOARD WITH010 x 1" SCREWS @ 6" O.C. STAGGERED = TOP AND BOTTOM (SEE DETAIL ABOVE) D.. PLACE COMPOSITE ROOF PANEL INTO HEADER AND ATTACH TO 4TH WALL POST AND BEAM SYSTEM ONLY. DO NOT ATTACH TO.HEADER. HEADER IS USED AS FLASHING ONLY. Lawrence E. Bennett, P.E. FL # 16644 CIVIL & STRUCTURAL ENGINEERING P.O. Box 214368, South Daytona, FI 32121 Telephone #: (386) 767-4774 Fax #.' (386) 767-6556 Email: lebpe@bellsouth.n8t PAGE I @ COPYRIGHT2006 F c .i S 21, ,fir>'IF t 7-6 1 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. SOLID ROOF PANEL PRODUCTS RIDGE CAP #8 x 9/16" TEK SCREWS @ PAN RIBS EACH SIDE CAULK ALL EXPOSED SCREW HEADS & WASHERS #8 x 1/2" S.M.S. (3) PER PAN AND (1) AT PAN RISER ALTERNATE CONNECTION: #8 x 1-1/4" SCREWS (3) PER PAN INTO BEAM THROUGH BOXED END OF PAN AND HEADER WHEN FASTENING TO ALUMINUM USE TRUFAST HD x ("t" + 3/4") AT 8" O.C. FOR UP TO 130 MPH WIND SPEED EXPOSURE "D"; 6" O.C. FOR ABOVE 130 MPH AND UP TO 150 MPH WIND SPEED' EXPOSURE"D CAULK ALL EXPOSED SCREW HEADS & WASHERS PAN ROOF ANCHORING DETAILS ROOF PANEL TO BEAM DETAIL SCALE: 3" = V-0" SECTION 7 SEALANT PAN HEADER (BREAK - FORMED OR EXT.) HEADERS AND PANELS ON BOTH SIDES OF BEAM FOR GABLED APPLICATION PAN OR COMPOSITE ROOF PANEL #8 x 1/2" S.M.S. (3) PER PAN ALONG PAN BOTTOM FOR PAN ROOFS: (3) EACH #8 x 1/2" LONG S.M.S. PER 12" PANEL W/ 3/4" ALUMINUM PAN WASHER ROOF PANEL FOR COMPOSITE ROOFS: (PER TABLES SECTION 71 #10 x (t + 1/2") S.M.S. W/ SUPPORTING BEAM 1-1/4"0 FENDER WASHERS (PER TABLES) @ 12" O.C. (LENGTH = PANEL THICKNESS + 1 ") @ ROOF BEARING ELEMENT (SHOWN) AND 24" O.C. @ NON -BEARING ELEMENT (SIDE WALLS OOF PANEL TO BEAM FASTENING DETAIL SCALE: 3" =1'-0" Lawrence E. Bennett, P.E. FL # 16644 CIVIL & STRUCTURAL ENGINEERING P.O. Box 214368, South Daytona, Fl 32121 Telephone #: (386) 7674774 Fax #: (386) 767-6556 Email: lebpe@bellsouth.net @ COPYRIGHT2006 NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E. BENNETT, P.E. PAGE 7-21 KNEE BRACES 2" X 4" X .045 9.00 1 KNEE BRACES 2"X41X .045 '.00 1 SEE ATTACHED SURVEY & ENGINEERING Site Address: 8193 Blackbead Ct. Roof Beam Layout Port St. Lucie, FL (2" x 6" 4th M11 Beam) Block: 01 - r------------- T--------- r-------l-r ' Lot : 04 _d mr------------- Tv------ "r------- °o' All construction On existingContractor: South Florida Aluminum Products (2"x9"Beam) (2"x9"Beam) (2"xs"Beam) I= 4801 South Highway #1 v� ®; Fort Pierce, FL 34982 _L_ y l_______L__-_-__ YL_L. Concrete slab. Phone # (772)-466-0913 (2" x 6" Edge Beam) Fax # (772)-466-1074 35.00' Scale Size: 1 " = 10' n w w W W W W X X' W w'. x w. X W' x W x '.W X- X' m coo X coo X coo I X X CD N N -6.00'-11 N -7.00'- N - 9.00'- N 9.001- .00' N 4th Wall View 3" 12.00' -a_ 12.00' x 024 Ins. Panels 3" x 48" x 024 Ins. PIsl D 2" x s" 2,. X g,.CV0 X/10.00' X W 9.00' X 9.00'X �M' Front View Rear View ROOFTYPE 3" X .024 Insulated Panel System 38.00' Up- ---a 11.00' 11.00' 0- cw W w W w w X'' X' W w'. X w X w.: X' G2 X Iw X-. X'. X X X. '.X -6.00'- -7.00'- 11 - 9.00'- 9.00'- .00' Right Side View THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. <(2" x 6" x .050) 4th M11 Beam KNEE BRACES 2' X 4" X .045 (2" x 6" x .050) EDGE BEAM KNEE BRACES TX 4" X .045 Brief Description: INST, Contractor's CARPORT DETAILS -EDGE BEAM LOAD = 4.00' (4-Span) -EDGE BEAM SIZE = 2" X 6" X .050 -MAX SPAN ALLOWED = 11'_ 11 " -ACTUAL SPAN = 6.00, 7.001, 9.00', & 4.00' -POST TO BEAM = 3" X 3" X .090 -INTERMEDIATE BEAM LOAD = 6.00' -INTERMEDIATE BEAM SIZE= 2" X 9" X _082, -MAX SPAN ALLOWED = 17 8 " -ACTUAL SPAN = 13.00', 9.00',& 4.00' -CARRIER BEAM LOAD(A) = 8.00' -CARRIER BEAM SIZE = 2" X 9" X .082 -MAX SPAN ALLOWED = 15 ' 5 " ACTUAL SPAN = 11.00' -CARRIER BEAM LOAD I =11 _00' -CARRIER BEAM SIZE = 2" X 10" X _092 -MAX SPAN ALLOWED = 15 ' 11 " -ACTUAL SPAN = 11.00' -CARRIER BEAM LOAD(C)=•9.00' -CARRIER BEAM SIZE = 2" X 9" X .082 -MAX SPAN ALLOWED = 14 ' 6 " -ACTUAL SPAN = 11. 00' -CARRIER BEAM LOAD(D) = 7.00' -CARRIER BEAM SIZE = 2" X 10" X. 092 -MAX SPAN ALLOWED = 19 ' 8 " -ACTUAL SPAN == 11. 00' -CARRIER BEAM LOAD(E) = 4.00' -CARRIER BEAM SIZE = 2" X 6" X _050 -MAX SPAN ALLOWED = 11. 00' -ACTUAL SPAN = 11. 00' -4th WALL BEAM LOAD = 6.00' (4-Span) -4th WALL BEAM SIZE = 2" X 6" X .050 -MAX SPAN ALLOWED = 11 '3 " -ACTUAL SPAN = 6.00', 7.00', 9.00', & 4.00' -POST TO BEAM = 3" X 3" X .090 -KNEE BRACES = 2" X 4" X .045 -ROOF TYPE = 3" X 48" X .024 INSULATED PANELS ALUMtlNUM CARPORT ON G CONCRETE SLAB Aare ®vi'LL � FA . 'C "'Z8 . le t3� �iT,4�Je