Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED _ Date: /' %� Permit Number:'(Iml-1 dG SCANNED BEDr y s / Lu cie ucie County - _ ty APR 12 2016 - - Building Permit Application Planning and Development Services I Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential PERMIT A.. O. �r0.... ®. ©� �© .. .._.�.... .0�, i - .,. .,..,.-� .. :. .. _�.�. g �- ._d;"-ram ... a.� r•r:r Address: EoO Legal Description: Property Tax ID #: 3 Y of eZ " 00 7 2 — e&V % Lot No. Site Plan Name: Block No. Project Name: Setbacks Front Back: Right Side: Left Side: Additional work to be pertormed under this permit -check all that apply: _Mechanical _ Gas Tank _ Gas Piping _ Shutters Electric _ Plumbing _ Sprinklers _ Generator Total Sq. Ft of Construction: Cost of Construction: $ Sq. Ft. of First Floor: Utilities: —Sewer —Septic Windows/Doors Roof Building Height: /101' 1'RACM0R, Name Name: Address: �009 a% Company`. „P��'��rd�{ City: 'Ity_ J�%��YG. State: le- Zip Code: 3$�9�� Fax: Phone No. 771 S'o23if6Y Address: City: State: Zip Code: Fax: Phone No E-Mail: P V';ez_e /S GL C4HI Fill in fee simple Title Holder on next page (if different from the Owner listed above) E-Mail State or County License If value of construction is 2500 or more, a RECORDED Notice of Commencement is required. 1 S ;; P�L;E iEN Al GQ1'Rtl1.CT LIEN L.l§W N:Fa MAC O;N: DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY: Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result.in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencine work or recordine vo_ur Notice of Commencement. Signature of Owner/ Lessee/Conti aactor as Agent for Owner STATE OF FLORIDA4 j COUNTY OF Signature of Contractor/License Holder STATE OF FLORIDA COUNTY OF The forgoing instru ent was acknowledged before me The forgoing instrument was acknowledged before me this 19L- day of 1PI(I 204 by this day of 20_ by (Name of person acknowledging) AN '�' V,\ ' c9-- (Signature of Notary Public- State of Florida) / Personally Known OR Produced Identification Type of IdentpfffiLcation Produced 1-1 z �• �--' - - �. . �r Commission No.� i (13�( (Name of person acknowledging) (Signature of Notary Public- State of Florida ) Personally Known _ Type of Identification KAREN S. NIELSE Commission 4 Fi!fbM 3?io No. My Commiss on Expires June 12 2018 OR Produced Identification (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE (� RECEIVED I COMPLETED 4 I M 0 JOSEPH E. SMITH, CLERK o,77 THE CIRCUIT COURT - SAINT LUCIE COL",, FILE # 4180601 OR BO(' 1358 PAGE 244, Recorded 04/15/2016 a, ?:20 PM u,✓ NOTICE OF COMMENCEMENT Permit No. �v y oao? Tax Folio No. o State of.9orida_. _ .. County of St. Lode . The underslgrred here6yg►ves nodri that improvement aA® be made to certain real property, and In accordance with Chapter713, Flodda Statutes the fc loWng infonnaym Is p Wded iti tt& Notice of CDmmenam nL Legal Dewiptlan of Property: (and street address if ava0able): General description Jy`��•i . ascription of irwevement: L 4— Owner hdpprtao g ar Lessee tq -formation If the Lessee contracted for the lmprovenneM: Name O 6-7` til Address SOO i0 NL T,P1L h P . cs mil L tL 7 Interest In property, Name and address offee slmpletitleholder (IfdHferentfrom Owner listed above): Contractors .f Phone -Number. 15`1fi4i r4 -A Ywe Surety (ifapplicable, a mpyof the paymentbmW is attached): Arwunt a f bond: $ Name and address: Phone number. lemlerNome: - PhogeKumber _ Lender s address Persons within the State of paid, deslpreted byOwlier upon wlibrrriatloes'or ogle, docpmerds may be served as provided Section „W(1) (am Rawa Statutes: br Name:.. Phone Number. . Address: In addition to himself or herself, Owner designates Uenor'sNotice az provided torecdveacopyofthe Phone number ofperson �(1) (b), Florida Statutes. - Person or entRydesignated hy.owner. Expiration date of notice of commencement: (the expiration date may notbe before the completion of construction and Heal a contractor, but will be 1 year from the date of recording unless a different date Ls specified) P Ymentto the WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF CAMEN�INENTARE CONSIDEREDIMPROPER PAYMENTS UNDER OWNER 713, PART I, SECRON,713.13, RORIDA`SfATUTES, AND CAN NIRESULT IN YOUR PAYING TWICE -FOR IMPROVEMENiS TO YOUR PROPERTY. A NOTICE OF W MMENCEMENT MUST BE RECORDED AND POSTED ON THEJOB SiTE BEFORE THE FIRST ' INSPECTION. IF YOU INTEND TO OBTAIN RNANONG, CONSULT WiTH YOUR LENDER tf R AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. . U!Mer wtidgeof a beige, l declare that I have. re d the foregoing notice of commencem" and that the facts stated therein are true to the best of ,myr•lmowledgeandbelleF. (SI nature of.Owrier or Lessee, or S d1 lessee's Ac CHERYL FREEMAN - Notary Public . slate-ot Florida My Comm, Expires JUI,12, 2- Commission ,r OF 104567 71going rostrum admoxAedged before me tftis `% " day of as— . nt4k- `. ' for ofauthority(eg offloer,trustee) Party anbehalfofwhominstrumertfwasotecutted PersonallyTmow�orproduoedldertlflcatl v *tuft0fN.6rqyputMWc*State&Flodda). .00k Not, Type, or Stamp Commissioned Name of Notary Public) Type of Identification produced 0. . STATE OF FLORIDA ST, LUCIE COUNTY THIS IS CERTIFY AT THIS IS A TRUE A D COR-REC OPY OF THE RIGI E. SM ERK By: puty Clerk Dote �Z-,2 Planning & Development Services Departmen E En!ED Building & Code Regulations 2300 Virginia Avenue ��� Fort Pierce, Florida 34982 12 2016 (772) 462-1553 IIY PERMITTING OWNERBUILDER AFFIDAVIT DISCLOSURE STATEMENT St. Lucie County, FL F.S. 489.103 (7) EXEMPTIONS State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You may build or improve farm outbuildings, a one -family or two-family residence for your use and occupancy. You may also build or improve a commercial building at a cost not exceeding $75,000.00 as long as it is for your own use or occupancy. You may not build or improve said structures for the purposes of selling or leasing that building. If you sell or lease a building you have built or improved within one year after construction is complete, then a presumption is created that it was built or improved for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Your construction must comply with all ap icable laws, ordinances, building codes, and zoning regulations. Initial I understand that the building official and inspectors are not there to design or give advice on how ip meet the minimum code. Initial I understand that as an owner -builder that any contract disputes with sub -contractors and I must be handled in a civil court with the advice of an attorney. This department will not mitigate any contract disputes. Initial Gf , I understand that if I compensate any person or company for work performed they are required to be licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and liable for the cost of the license. Initial -A/Al- I understand that if any person that is unlicensed and uninsured gets injured on my construction project - they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and relate,d� edical ,� cost, which could include loss of wages during recovery from their injury. Initial t To qualify for this exemption under this subsection, an owner must personally appear and sign the building permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owner/builder exemption shall be reported by the Building and Zoning Department to theFlorida State Department of Professional Regulation. Signed and acknowledged on this � day of ,429,' / of 20 . Owner/Builder Signature STATE OF FLORID COUNTY OF tA- TLhe foregoing instrumen was acknowledged before me this 1 day of1�t,20—�, by �t=,���lt �I who is personally known to me, or who has produced h, Cas identification. i \ '�4e L V�Ud 1�5�� �""""''� KAREN S. NIELSEN Signatureof otary Type or Print Name of .'z�``pr ° eagommission N FF 115637 Title: Notary Public Commission Number r= My Commission Expires SLCPDSD Revised 05/15/2014 STRUCTURAL DESIGN FREE-STANDING LEAN-TO MONOSLOPE OPEN CARPORT. BUILDING MAXIMUM 24'-0" WIDE X 16'-099. EAVE HEIGHT— BOX EAVE FRAME Tl iESE PLA145 AND A,.L pROpOSED WO;K 21 October 2015 RECEIVED ARE SUBJECT TO ANY CORRECTIONS Revision 6 APR 12 20% REQUIRED BY FIELD INSPECTOR4 THAT M&A Project No.15127S PERMITTING MAY BE NECESSARY IN ORDER T®;s4 St. Lucie county, FL CAlPIr�H Prepared for: - nvvST. Luc korB�f,2o!-Y Ni= DIVISION Bennett Building. Systems, LLCR-16WEWED FOR IAN'CE 1660 Dixon Airline Road RE.VIEIN T BY �p���ALED FASTENERS OR A�T�CHME�lT4 Augusta, Georgia 30906 DATE In RESPONSIBILITY OF THE PLANS PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. CflNiA�CiOR O� P CORD Prepared by: Moore and Associates Engineering and Consulting, Inc. 1009 East Avenue North Augusta, SC 29841 MOORE AND ASSOCIATES ENGINEERING AND CONSULTING `,,1tI11111, $ ,.,%'� j� j CAR �''% S L - 26784 i. ••�0 S. t�®,e���, 1111U11,1”' „la�uuutwrh+�rrrr MOORE 'n AND _ ASSOCIATES, INC.1 No. CO2968 04 .,•4 L�• rrr''rrtrOrjj IUt��,,• ``,tltt111 Iilllt111ff(/r,Ilk rmoo re and miatesgomdng and Consuttfng, Inc. No. C41166 OF1A `oIIII11111 o�`% \ ; A B'� �Lj'#,o ::E N .334 6-E P FESSIONAL; -'-)_ 11111I11 V N8 S. MOORE 1c. No. 051637 10/-Zt/is ``I%IIIKIIIIEA,I % r-D: WAYNE S. s ,* I _ M-G9RF-i 's * F sc�EP1SE 4 ,,�® NrG S. Y6,i�0�i %,++ `,�.�P• E N�F•.; P,y'"••••Ae OF • * : No 71 W ° S. MOORE tq00i 10/2t/IS ;'cL'.. ' GG1 E ? a• STATE OF : �It/ S "o•,'qp .9p, �k,C a1. 0��,,,. • ••0 R 0 •° �� �0 ••°°•°•• •V see.•- S . 40.-.,��. SjQ�.'•��t^D �'jj'•O�� c:� Gig, •. ;N9 �' •. Na o2a �•'' c�C-i OF TEN �'oo AND ASSOCIATES GINEERING AND CONSULTING, INC. BENNETT BUILDING SYSTEMS, LLC OPEN CARPORT LEAN-TO PE SEAL COVER SHEET my DRAWING INDEX SHEET I PE SEAL COVER SHEET SHEET 2 DRAWING INDEX SHEET 3 INSTALLATION NOTES AND SPECIFICATIONS AND TYPICAL SIDE AND END ELEVATIONS SHEET 4 TYPICAL RAFTER/POST END AND SIDE FRAMING SECTIONS AND CONNECTION DETAILS SHEET 5 BASE RAIL ANCHORAGE OPTIONS SHEET 6 BASE RAIL ANCHORAGE OPTION FOR CAST IN PLACE ANCHORS SHEET 7 BOX CAVE RAFTER GABLE END OPTIONS AND CONNECTION DETAIL SHEET B BOX CAVE RAFTER EXTRA SIDE PANEL OPTION ELEVATION AND SECTION SHEET 9 VERTICAL ROOF OPTION SIDE ELEVATION AND SECTION MOORS AND ASSOCIATES IBRAWN 13Y. .IRS BENNETT BUILDING SYSTEMS, LLC GINEERING AND CONSULTING, INC. MEe1cED sr. PDH OPEN CARPORT LEAN-TO MAT BOX EAVE FRAME RAFTER OPEN CARPORT LEAN-TO BUILDING TYPICAL END ELEVATION -HORIZONTAL ROOF SCALE, 1/8' z 1'-0' ram-- j-=_<.-=.---------- s i I P q 1 Y � LENGTH VARIES DEPENDING ON NUMBER AND SPACING OF RAFT.tRS LASHING 3PTIIDIALI TYPICAL SIDE ELEVATION -HORIZONTAL ROOF SCALE: 1/8' = 1'-0' INSTALLATION NOTES, AND SPECIFICATIONS 1. DESIGN 1S FOR A MAXIMUM 24' WIDE x 16' EAVE HEIGHT LEAN-TO STRUCTURES 2. DESIGN WAS DONE IN ACCORDANCE WITH THE 2014 FLORIDA BUILDING CODE (FBC) 5TH EDITION, 2006 INTERNATIONAL BUILDING CODE (IBC), 2009 IBC AND 2012 IBC, 3 DESIGN LOADS ARE AS FOLLOWS; A) DEAD LOAD = I PSF B) LIVE LOAD = 12 PSF C) GROUND SNOW LOAD - 30 PSF 4. ULTIMATE WIND SPEED 105 TO 140 MPH (NOMINAL WIND SPEED 81 TO 108 MPH) MAXIMUM RAFTER/POST AND END POST SPACING = 50 FEET. 5- ULTIMATE WIND SPEED 141 TO 170 MPH (NOMINAL WIND SPEED 109 TO 132 MPH): MAXIMUM RAFTER/POST AND END POST SPACING = 4.0 FEET, 6. LOW HAZARD RISK CATEGORY I (WIND), 7. W114D EXPOSURE CATEGORY B. B. SPECIFICATIONS APPLICABLE TO 26 AND 29 GAUGE METAL PANELS FASTENED DIRECTLY TO 3' x 2' - 15 GAGE S"EEL TUBE FRAMING MEMBERS. 9, AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS OR PURLINS, AND POSTS (INTERIOR OR END) = 6 INCHES, 10 FASTENERS CONSIST OF 1/4'-14x3/4' SELF -DRILLING SCREWS WITH CONTROL SEAL WASHER, SPECIFICATIONS APPLICABLE ONLY FOR MEAN ROOF HEIGHT OF 20 FEET OR LESS, AND ROOF SLOPES OF 14' (3112 PITCH) DR LESS SPACING REQUIREMENTS FOR OTHER ROOF HEIGHTS AND/OR SLOPES MAY VARY, 11, GROUND ANCHORS CONSISTING OF #4 REBAR W/WELDED NUT x 24' LONG MAY BE USED FOR LOW (< 108 MPH NOMINAL) WIND SPEEDS ONLY. 12 GROUND ANCHORS SHALL BE INSTALLED THROUGH BASE RAIL WITHIN 6' OF EACH POST, 13- OPTIONAL BASE RAIL ANCHORAGE MAY BE USED FOR LOW AND HIGH C > Ill MPH - 139 MPH NOMINAL) WIND SPEEDS 14. WIND FORCES GOVERN OVER SEISMIC FORCES, SEISMIC PARAMETERS ANALYZED ARE, SOIL SITE CLASS = D RISK CATEGORY I/Cl/III R= 3,25 IE= ID SDS= 1,522 V= CSW SDI= 0.839 MOORE AND ASSOCIATES IDRAWN IIY- .IRS BENNETT BUILDING SYSTEMS, LLC INEERING AND CONSULTING, INC. NECKED BY, PDH _ OPEN CARPORT LEAN-TO Is PAT 26 OR 29 GA. GALVANIZED METAL ROW AND WALL PANELS FASTENED TO RAFTERS AND POSTS WITH 1/4'r3/4' SDCS WITH CONTROL SEAL WASHER B AVERAGE 6' O.0 SPACING 12 Z TO 12 SLOPE SHOWN OPTIONAL SLOPES CAN BE 1 TO 12 OR 3 TO 12 u u LENGTH VARIES DEPENDING ON ur,unra Aun eoarpuc nr vnrrrvc 3 SEE NOTES (PAGE 3) FOR MAXIMUM SPACING 5 3 6 TYPICAL RAFTER/POST END FRAME SECTION TYPICAL RAFTER/POST SIDE FRAMING SECTION SCALE, 1/B' = 1'-0' SCALE, 1/8' - 1'-0' IS BOX CAVE RAFTER ]rl6 NIPPLE TO RAFTER 4111A 3+12 3+12 6' 24' 16 GA. U-CHANNEL BRACE NIPPLE VIEACH (URP TO 7' POST) BASE R 4B' 16 GA. U-CHANNEL BRACE (0' TO 16' POST) NIMUM 6' LONG. MINIMUM 15 GA.. NIPPLE SECURE POST TO NIPPLE ITH 14)1/4'r3/4• SOF'S TS RAFTER PGST TYP ]-12 BDX EAVE RAFTER/CORNER 1 POST ONNECTION DETAIL SCALE NTS MOORE AND ASSOCIATES PEERING AND CONSULTING, INC. IT Is INC PROPERTY OF MOORS AND ASSOCIATCs. INC. INC NINI�f TDOCUMENT tS ITED ANO�RINGEIENT THEREUPON is POST MINIMUM 6' LDNG,,HINIMUH 15 GA. TS NIPPLE SECURE WITH (6) 1/4'.3/4' SOF'S e� 16 el e: TS CONTINUOUS BASE RAIL {�- POST/BASE RAIL 2E, CNN TI-DETAIL SCAL NTS 16 GA. U-CHANNEL BRACE FASTENED TG THE LCG AND 2' RAFTER. WITH (2) 1/4'a3/4• SDF S AT EACH END (4 PER BRACE) BRACE SECTION SCALE, NTS BRAWN BY, JRS BENNETT BUILDING SYSTEMS, LLC CHECKED BY. PDN OPEN CARPORT LEAN-TO RDJECT wa VSM DATE) 10-20-13 SCALE) NTS JOB NO 15127S BASE RAIL ANCHORAGE OPTIONS FOR LOW AND HIGH WIND SPEEDS INSTALL_ 1/2'r6' EXPANSION INSTALL t/2'x6• EXPANSION ANCHOR THROUGH BASE RAIL ANCHOR THROUGH BASE RAIL DR FIBERGLASS WITHIN 6' OF EACH VYF OR FIBERGLASS // WITHIN 6. Of CACN e POST FIBERS POST `v M D16�I_I IIJI I" _ INIMUM 2 MINIMUM 2 :It.* £NEMHE EMBEDMENT I (TYP.) s�' A • g —(-I"II_ ' (TYP.) MONOLITHIC CONCRETE FOOTING —v ��� �' MONOLITHIC CONCRETE TOOTING --✓ (3000 PSI MIN.) REINTORCED `T I I -I I I I ( c3000 PSI MIN.) REINFORCED '� I I -I ( I WITH (2) o4's CONTINUOUS �'_�' g 5�$" WITH (t) �i's CONTINUOUS 1,_0- CONCRETE MONOLITHIC SLAB TS 3A BASE NRAIL ANCHORAGE MINILE SCALEa MUM ANCHOR EDGE DISTANCE IS 6 3/4', GENERAL NOTES CONCRETE: CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 3,000 PSI AT 26 DAYS. COVER OVER REINFORCING STEEL: FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFORCING BARS SHALL BE PER ACI-3I8 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH OR EXPOSED TO THE EARTH OR WEATHER, AND 1 112 INCHES ELSEWHERE. REINFORCING STEEL, THE TURNDOWN REINFORCING STEEL SHALL BE ASTM A615 GRA 60. THE SLAB REINFORCEMENT SHALL BE WELDED WIRE FABR MEETING ASTM A185 OR FIBERGLASS FIBER REINFORCEMENT, REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED: I REINFORCEMENT IS DENT COLD, 2 THE DIAMETER OF THE BEND, MEASURED ON THE INSI E OF THE BAR, IS NOT LESS THAN SIX —BAR DIAMETERS. 3 REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE HALL N07 BE FIELD BENT. HELIX ANCHOR NOTEST CONCRETE SLAB BASE 3B RAIL ANCHORAGE SCALE NTS MINIMUM ANCHOR EDGE DISTANCE IS 6 3/4'. IT OR SURFACE THROUGH THE SA IL AND SECURE TO ANCHOR E V1TH 1/2' DIAMETER THROUGH 0-T El ---1 1 �I III-11i ;��I II I. _I 11 ! 1. 11 TS CONTINUOUS BASE RAIL DOUBLE HELIX EYE ANCHOR (SEE NOTES BELOW) I FOR VERY DENSE AND/DR CEMENTED SANDS, COARSE G VEL GROUND BASE HELIX ANCHORAGE AND COBBLES, CALICHE, PRELOADED SILTS AND CLAYS SE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT. SCALE NTS (CAN BE USED FOR ASPHALT) 2 FOR CORAL USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 NCH EMBEDMENT. 3 FOR MEDIUM DENSE COARSE SANDS, SANDY GRAVELS, VERY STIFF SILTS, AND CLAYS USE MINIMUM (2) 4' HELICES WITH MINIMUM 30 INCH EMBEDMENT 4, FOR LOOSE TO MEDIUM DENSE SANDS, FIRM TO STIFF CLAYS AND SILTS ALLUVIAL FILL USE MINIMUM (2> 6' HELICES WITH MINIMUM 50 INCH EMBEDMENT. 5, FOR VERY LOSE TO MEDIUM DENSE SANDS, FIRM TO STIFFER CLAYS AND SILTS, ALLUVIAL FILL USE MINIMUM (2) B' HELICES WITH MINIMUM 60 INCH EMBEDMENT. MOORE AND ASSOCIATES GINEERING AND CONSULTING, INC. ACTION, CDPTING, OR OTHMISE USE OF THIS DOCUIENT IS ANG ANT IIiRIW WENT THEREUPON H11T EC SUBACT TO BENNETT BUILDING SYSTEMS, LLC OPEN CARPORT LEAN-TO BASE RAIL ANCHORAGE OPTION FOR CAST -IN -PLACE ANCHORS LOW AND HIGH WIND SPEEDS INSTALL 1120 ANCHOR ROD THROUGH BASE RAIL nR rfRERGLASS WITHIN 61 DF EACH POST (SEE DETAIL 'A') . . 2• a 4 I 0 o I— �'- MINIMUM 6• •i I 4 i d 1— I ET BPEDHENT fl1—III _ MONOLITHIC CONCRETE FOOTING ME (3000 PSI MIN.) REINFORCED I I —I 11 1 (3 WITH (2) 14's CONTINUOUS W CONCRETE MONOLITHIC SLAB 3A BASE RAIL ANCHORAGE SCALE- NTS GENERAL NOTES CONCRETE: CONCRETE SHALL HAVE A MINIMUM SPECIFI COMPRESSIVE STRENGTH OF 3,000 PSI AT 2B DAYS. COVER OVER REINFORCIN STEEL( FOR FOUNDATIONS, MINIMUM CONCR COVER OVER REINFORCING BARS SHALL BE PER ACI_318: 3 INCHES IN FOUNDATIONS WH THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTA WITH THE EARTH OR EXPOSED TO THE EARTH OR WEATHER, 1 1/2 INCHES ELSEWHERE. REINFORCING ST L: THE TURNDOWN REINF CING STEEL SHALL BE ASTM A615 GRADE 60. THE SLAB REINF RCEMENT SHALL BE WELDED WIRE FABRIC MEETING ASTM Al OR FIBERGLASS FIBER REINFORCEMENT. REINFORC ENT MAY BE BENT IN THE SHOP 0 THE FIELD PROVIDED- 1, REINF CEMENT IS BENT COLD 2 THE IA14E'ER OF THE BEND, MEASURED ON THE INSIDE OF THE BAR, IS NOT LESS THAN SIX —BAR DIAMETERS 3 REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT. MOORE AND ASSOCIATES ENGINEERING AND CONSULTING, INC. THIS DOCUMENT IS THE PROKRTT OF HOOK AND ASSOCIATES. IIG TIE IIHAIITNORIZED RCU'RODUCTION, CQTING, OR OTHERWISE USE OF THIS DOMWNT IS STRICTLY PROHIl:TED AND ANT IHFRINGEMENT THEREUPON MAY K SUD.IECT TO LEGAL ACTIML WWF OR FIBERGLASS FIBERS a 4q � 4 NINHUM 4 a • IC CONCRETE FOOTING—✓ ' 1 MIN.) REINFORCED 1-1T"t1 04's CONTINUOUS CONCRETE. SLAB BASE 3B wAIL ANCHORAGE INSTALL 1/20 ANCHOR ROD THROUGH BASE PAD, WITHIN 6. OF EACH POST (SEE DETAIL THIS SHEET) GRADE �o u 6 1/2'R A36 THREADED ROD 7/CDNCRETC F1 , m W tie H VY HE NUT TYPICAL CAST —IN PLAC ANCHOR ROD DETAIL SCALE= NTS BENNETT BUILDING SYSTEMS, LLC OPEN CARPORT LEAN-TO BOX RAFTER GABLE END OPTION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION SCALE, 1/8' = 1'-0' D D NIPPLE RAFTER IS BOX CAVE —1 V2'.1 V2'.2. 16 GA. CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL V/(0 1/4'.3/4' SDF'S 2 ON TOP, 2 ON SIDE MINIMUM 6' LONG, MINIMUM 15 GA., TS NIPPLE. SECURE POST TO NIPPLE WITH (tl 1/4'.3/4' SOF'S S POST SEE NOTES (PACE 31 FOR MAXIMUM SPACING i 71@ wy W_ �W y J TYPICAL BOX EAVE RAFTER GABLE END FRAMING SECTION SCALE; 1/8' = 1'-0' is POST ---- IS GABLE RAIL 1 1/2'.1 1/2'.2' 16 GA. CLIP ANGLE SCCURE TO BOX EAVE RAFTER AND GABLE RAIL W/(41 1/4'.3/4' SDC'S 2 ON TDP, 2 ON BOTTOM (BOX- EAVE RAFTER GALE RAIL TO 4 RAFT R PT NN TI N D TAIL SCA E NiS MOORS AND ASSOCIATES GINEER.ING AND CONSULTING, INC. is BENNETT BUILDING SYSTEMS, LLO OPEN CARPORT LEAN-TO mo BOX EAVE RAFTER OPEN CARPORT EXTRA SIDE PANEL OPTION — — oa rs rel —ws7rn urt Al onnr Anti 1iAe I TYPICAL END ELEVATION EXTRA SIDE PANELS SCALE: 1/9' = V-0' MOORE AND ASSOCIATES PEERING AND CONSULTING, INC. is :: ��32...^..'.r..•�--�t�^_� :..may.....-.--...�.. .--..-....�.: e�1�'C �-.»�: �.!'..^. �_ LENGTH VARIES PENDING (IN FLASHING NUMBER AND SPAEIN OF RAFTERS (OPTIONAL) TYPICAL SIDE\ELEVATION EXTRA SIDE PANELS SCALE, 1/8' = 1'-0' BENNETT BUILDING SYSTEMS, LLC OPEN CARPORT LEAN-TO Be BOX EAVE RAFTER VERTICAL ROOF _OPTION 24' MAXIMUM RAFTER SPAN r TYPICAL END ELEVATION VERTICAL ROOF SCALE, 1/8' - 1'-0' LENGTH VARIES DEPENDING ON NUMBER AND SPACING OF RAFTERS I TYPICAL SIDE ELEVATION VERTICAL ROOF SCALE! 1/8' = 1'-0' 26 OR 29 GA. GALVANIZED PANELS FASTENED TO PURL 1/4'u3/4' SDF S WITH CON SEAL WASHER @ AVERAGE 1 SPACING 12 METAL ROOF 'INS WITH TRILL 6. BE '-0w6. 10 GAUGE FURRING CHANNEL CPURLIN) 2 40' VC NAX TYPICAL SECTION VERTICAL ROOF OPTION SCALE, 1/8' = 1'-0' 836' IB GAUGE FURRING CHANNEL FASTENER TO ACN RAFTER WITH (2) 1/4'X3/4' SPF'S SPACED NOT ORE THAN 48. O.0 LENGTH VARIES DEPENDING ON NUMBER AND SPACING OF RAFTERS SEE NOTES (PAGE 3) FOR MAXIMUM TYPICAL FRAMING SECTION VERTICAL ROOF OPTION SCALE-. 1/8' = P-0' 0.836' SO GAUGE FURRING CHANNEL ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS) SCALE' NTS MOORS AND ASSOCIATES pRA BYe .IRS BENNETT BUILDING SYSTEMS, LLC PEERING AND CONSULTING, INC. Hump Btt( POH OPEN CARPORT LEAN-TO IT IS 1HE PROPE4Ttt OF IOOit AND ASSOCIATES. 1►H THE ROJECT HGlb VSM DATE& 10-20-15 SCALE, NTS JOB NO: 1! I REM10011CTION C09TING. OR OTHERVISE USE 01 THIS OOGtI1�JIT IS L11®ITED IwD AHry INT1iINGEKNT 71[REUPOI M11T DE SUIJECT TO LIENT= T 9 IDWG.K-I 6EV.3 1 1/14/2016 Florida. Building Code Online FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence FL17031-R1 Affirmation v 9'k 2014 Approved APR 12 2016 PERMITTING g St. Lucie County, FL Bennett Building Systems 1660 Dixon Airline Rd Augusta, GA 30906 (877) 830-7086 Ext7440 tanner.dant@bennettig.com Tanner Dant tanner.dant@bennettig.com Chris Cable 1660 Dixon Airline Rd Augusta, GA 30906 (706) 945-8818 chris.cable@bennettig.com Structural Components Roof Deck Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer (:.. Evaluation Report - Hardcopy Received Wayne S. Moore, P.E. PE-57170 National Accreditation & Management Institute 12/31/2018 Ted Berman, PE €..' Validation Checklist - Hardcopy Received FL17031 RI COI Evaluation Report Roof Deck.odf Referenced Standard and Year (of Standard) Standard Year ASTM E 1592 2001 Equivalence of Product Standards Certified By Florida Licensed Professionalmi.01i ch ec- FL17031_R1_ Eouiv Eouiv Lett Sections from the Code https://www.floridabuiiding.org/pr/pr app dfl.aspx?param=wGEVXQwtDgv2aBQpHpQQegQRH%2fzyGHDYdWgNXpmGSmG%2fO%2fw7JBi4%2fQ%3d%3d 1/3 ` 1/14/2016 Florida Building Code Online C ' I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity ()Yes " No "'.)N/A FL17031 RI COC Certificate of Compliance TBA 15-0922.01- sianed.12df Product Approval Method Method 1 Option D Date Submitted 09/25/2015 Date Validated 09/25/2015 Date Pending FBC Approval Date Approved 09/28/2015 Summary of Products FL # Model, Number or Name Description 17031.1 AG Panel Low Wind Speed Limits of Use Installation Instructions Approved for use in HVHZ: No FL17031 R1 II SK-9 AG Panel Roof Low.odf Approved for use outside HVHZ: Yes erl le oore, P.E. 57170 Impact Resistant: No Created by Independent Thir Yes Design Pressur - Eva u orts Other: A ent of th ost shall be designed by a Florida FL17031 Rl AE Eva ua rt Roof Deck. Prof onal Engineer and approved by the local jurisdiction. Created by Independent Third Party: 17031.2 AG Panel High Wind Speed Limits of Use Installation Instructions Approved for use in HVHZ: No FL17031 RI II SK-10 AG Panel Roof Hiah.odf Approved for use outside HVHZ: Yes 7031 R1 II SK-15 Tube.pdf Impact Resistant: No By: Wayne S. Moore, P. Design Pressure: +20.9/-18.9 • ttachment of the post shall be designed �Verjfied ated b Ir Party: Yes uation Reports Professional Engineer an a rove y e local jurisdiction. FL17031 R1 AE Evaluation Report Roof Deck.pdf Created by Independent Third Party: Yes 17031.3 AG Panel Metal Roof Limits of Use Installation Instructions Approved for use in HVHZ: No FL17031 R1 II SK-4 AG Panel Roof-Rev.odf Approved for use outside HVHZ: Yes Verified By: Wayne S. Moore, P.E. 57170 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +17.5/-27.8 Evaluation Reports Other: Attachment of the post shall be designed by a Florida FL17031 R1 AE Evaluation Report Roof Deck (22) signed by w5m 070214.pdf Professional Engineer and approved by the local jurisdiction. Created by Independent Third Party: Yes 17031.4 Hat Channel Low Wind Speed Limits of Use Installation Instructions Approved for use in HVHZ: No FL17031 R1 II SK-1 Hat Channel Roof Low.odf ,Approved for use outside HVHZ: Yes Verified By: Wayne S. Moore, P.E. 57170 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +16/-16 Evaluation Reports Other: Attachment of the post shall be designed by a Florida FL17031 RI AE Evaluation Report Roof Deck.pdf Professional Engineer and approved by the local jurisdiction. Created by Independent Third Party: Yes 17031.5 Hat Channel High Wind Speed Limits of Use Installation Instructions Approved for use in HVHZ: No FL17031 RI II SK-2 Hat Channel Roof Hiah.pdf Approved for use outside HVHZ: Yes Verified By: Wayne S. Moore, P.E. 57170 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +20.9/-18.9 Evaluation Reports Other: Attachment of the post shall be designed by a Florida FL17031 R1 AE Evaluation Report Roof Deck.pdf Professional Engineer and approved by the local jurisdiction. Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 httpsJ/www.floridabuilding.org/pr/pr app dfl.aspx?param=wGEVXQwtDgv2aBQpHpQQe9QRH%2fzyGHDYdWgNXpmGSmG%2fO%2fW7JBi4%2fQ%3d%3d 2/3 ` 1/14/2016 Florida Building Code Online The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: W © eCkx �Greditr4rd https://www.floridabuilding.org/pr/pr_app dW.aspx?param=wGEVXQwtDgv2aBQpHpQQegQRH%2fzyGHDYdWgNXpmGSmG%g2fO%2fw7JBi4%2fQ%3d%3d 3/3 3.125 _2.750 3.125 (TYP.) ''(1'YP.) I (TYP.) AG PANEL PROFILE PnOF - T-lrTG14 WTNn CPFFn TOOLING STANDARD ASC SET WITH 44' TOOL SPACE (22' CENTER LINE) 3' BORE AND 6.026' PITCH DIAMETER NOTE1 1. ALL INSIDE BEND RADII ARE 0.062' EXCEPT WHERE NOTED 2. DIMENSIONS ARE BASED ON 0,020' MATERIAL. 3. ALL HEIGHT DIMENSIONS ARE TOP OF SHEET 1*0 TOP OF SHEET. 18.000 DISAPPROVED�}tESUBMtT CHECKED E G7AT 413D1t F 2/ZO/i h _ .i6AHDAS90CIAiEs �%u0;� STATE OF �W ?,RAL NOTES WAS DONE IN ACCORDANCE WITH THE 2010 Fl_ORIDA NG CODE WITH 2O12 SUPPLEMENT AMENDMENTS. LOADS ARE AS FOLLOWS D LOAD = 1.5 PSF E LOAD = 12 PSF LTIMATE WIND SPEED 141 TO 170 MPH (NOMINAL ;PEED 109 TO 1:32 MPH): MAXIMUM RAFTER/POST AND END ;PACING = 4.0 FEET. ATE.GORY 1. :XPOSURE CATEGORY B. GE FASTENER SPACING 0N-CENTERS ALONG RAFTERS OR IS, AND POSTS <INTERIOR OR END> = 6 INCHES. 4ERS CONSIST OF 1/4'--14x3/4' SELF -DRILLING SCREWS ;ONTROL SEAL WASHER. SPECIFICATIONS APPLICABLE ONLY '.AN ROOF HEIGHT OF 20 FEET OR LESS, AND ROOF SLOPES (3:12 PITCH) SPACING REQUIREMENTS FOR OTHER ROOF S AND/f.IR SLOPE'S MAY VARY. AMERICAN TEST LAB NORTH DATE 04128/14 REPORT NO, ATLNC 0414.01-14 ATL INSPECTOR POSITIVE ROOF PRESSURE: 20.9 PSF NEGATIVE ROOF PRESSURE: -I8.9 PSF 29 GAGE CALCULATED COIL WIDTH: 43-13/16, @ t = .020' THICKNESS RANGE: .015'-.020' GRADE OF MATERIAL: 80 KSI MIN TOLERANCE STANDARDS FOR THICKEST METAL: )ACCUMULATION --- (+ OR -) 1/16 IN DEPTH - --- (+ OR -) 1/32 IN RADII --__.. _-___ (+ OR -) 1/32 IN ANGLES -< - r (+ OR -) 2 DEGREES CAMBER _..- -.(+ OR -) 1/8 IN IN 10 FT SKI --•--<- - (+ OR -) 1/8 IN IN 10 FT DIVE - U OR -) 1/8 IN IN 10 FT xNET VARIA710N FOR COMBINED DIMENSIONS i acn to K-10 a V APR 12 2015 PERMITTING St. Lucie County, 1 ! may'. A_1 soo9� pItie T�-e-e V�' (rAof 41-e— , MIN. SETS G PEQ. FRONT / SIDES D CNR SIDES i REAR-_ ZNG. TECH.