HomeMy WebLinkAboutSUBMITTED PAPERS_2r
FORM-60OA-2004R EnergyGauge® 4.5.2
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
. Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: Civiletto Residence Builder:
Address: A>7�3 Alb WPl NW Permitting Office: St. Lucie Coun
City, State: Ft. Pierce, FL Permit Number:
Owner. Jurisdiction Number:
Climate Zone: Central
1.
New construction or existing
New _
2.
Single family or multi -family
Single family _
3.
Number of units, if multi -family
1 _
4.
Number of Bedrooms
4 _
5.
Is this a worst case?
Yes
6.
Conditioned floor area (W)
2035 ft2 _
7.
Glass typel and area: (Label reqd.
by 13-104.4.5 if not default)
a. U-factor:
Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 465.0 ft
b. SHGC:
(or Clear or Tint DEFAULT)
7b. (SHGC=0.6) 465.0 ft'
8.
Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 125.0(p) ft _
b. N/A
_
c. N/A
_
9.
Wall types
a. Concrete, Int Insul, Exterior
R=7.5, 1813.9 ft2
b. Frame, Wood, Adjacent
R=11.0, 61.0 ft2 _
c. N/A
_
d. N/A
_
e. N/A
_
10. Ceiling types (white roof)
_
a. Under Attic
R=30.0, 1106.0 ft2
b. N/A
_
c. N/A
_
11. Ducts(white roof)
_
a. Sup: Unc. Ret: Con. AH: Attic
Sup. R=6.0, 250.0 ft
b. N/A
12. Cooling systems
a. Central Unit
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
(11R-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.23 Total as -built points: 26768 PASS
.4 Total base points: 26920
I hereby certify that the plans and spe fi do d by
this calculation are in compliance with on rgy
Code. (
PREPARED BY: 4�". /2 L G IC t r
DATE: Z ZA1 0 7
I hereby certify that this bui i g, as designed, is in compliance
with the Florida Energy C
OWNERIAGENT:
DATE: ^ 7,
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
Cap: 42.0 kBtu/hr _
SEER: 15.00
Cap: 42.0 kBtu/hr
HSPF: 8.50
Cap: 40.0 gallons
EF: 0.97
MZ-C, PT, CF, MZ-
1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass out ut on p es
EnergyGauge® (Version: FLRCPBt44��' /
R
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 85.9
The higher the score, the more efficient the home.
, , Ft. Pierce, FL,
1. New construction or existing
New
2. Single family or multi -family
Single family _
3. Number of units, if multi -family
1
4. Number of Bedrooms
4 _
5. Is this a worst case?
Yes _
6. Conditioned floor area (ft2)
2035 ft2
7. Glass typel and area: (Label reqd.
by 13-104.4.5 if not default)
a. U-factor:
Description Area
(or Single or Double DEFAULT) 7a(Sngle Default) 465.0 ft2
b. SHGC:
(or Clear or Tint DEFAULT)
7b. (SHGC=0.6) 465.0 ft2
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 125.0(p) ft _
b. N/A
_
c. N/A
_
9. Wall types
a. Concrete, Int Insul, Exterior
R=7.5, 1813.9 ft-
b. Frame, Wood, Adjacent
R=11.0, 61.0 ft2 _
c. N/A
d. N/A
_
e. N/A
_
10. Ceiling types (white roof)
a. Under Attic
R=30.0, 1106.0 ft2 _
b. N/A
_
c. N/A
_
11. Ducts(white roof)
a. Sup: Unc. Ret: Con. AH: Attic
Sup. R=6.0, 250.0 ft
b. N/A
12. Cooling systems
a. Central Unit
b. N/A
c. N/A
13. Heating systems
a. Electric Heat Pump
b. N/A
c. N/A
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
BF -Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final igspection. erwise, a new EPL Display Card will be completed
based on installed Code fompliant fe es.
Builder Sienature: // �i -��liy,.�r Date:
t Address of New Home: City/FL Zip:
Cap: 42.0 kBtu/hr
SEER: 15.00
Cap: 42.0 kBhVhr _
HSPF: 8.50
Cap: 40.0 gallons _
EF: 0.97 _
MZ-C, PT, CF, MZ-
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStar'mdesignation),
your home may qualij� for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building
Construction, contact the Department of Community Affairs at 8501487-1824.
1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4.
EnergyGauge® (Version: FLRCPB v IL5100: CO Py
• ` 4 t �
_ r
Ft. Pierce, FL
Summary Energy Code Results
Residential Whole Building Performance Method A
Project Title:
Civiletto Residence
Code Only
Professional Version
Climate: Central
12/19/2007
Building Loads
Base
As -Built
Summer: 40179 points
Summer:
44668 points
Winter: 7261 points
Winter:
11891 points
Hot Water: 9053 points
Hot Water: 9053 points
Total: 56492 points
I Total:
65612 points
Energy Use
Base
As -Built
Cooling: 13058 points
Cooling: 11498 points
Heating: 4022 points
Heating: 5937 points
Hot Water: 9840 points
Hot Water: 9333 points
Total: 26920 points
Total: 26768 points
—i
PASS
e-Ratio: 0.99
EnergyGaugeST,-OT�
IiL%%ieE
FORM 60OA-2004R EnergyGauge® 4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
_ V
ADDRESS: , Ft. Pierce, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM = Points
Overhang
Floor Area
Type/SC
Omt
Len
Hgt Area X SPM X SOF = Points
.18 2035.0 24.35 8919.0
1.Single, SHGC=0.6
N
1.0
5.0
15.0
22.38
0.96
322.0
2.Single, SHGC=0.6
W
1.0
1.3
7.5
44.35
0.61
202.0
3.Single, SHGC=0.6
E
0.0
0.0
22.5
49.38
1.00
1111.0
4.Single, SHGC=0.6
E
1.0
3.0
9.0
49.38
0.85
379.0
5.Single, SHGC=0.6
W
1.0
4.0
24.0
44.35
0.92
974.0
6.8ingle, SHGC=0.6
W
1.0
5.0
45.0
44.35
0.95
1895.0
7.Single, SHGC=0.6
S
8.0
5.0
30.0
36.80
0.51
565.0
8.Single, SHGC=0.6
E
1.0
6.0
15.0
49.38
0.95
703.0
9.8ingle, SHGC=0.6
E
1.0
5.0
22.5
49.38
0.95
1055.0
10.Single, SHGC=0.6
S
10.0
5.0
10.0
36.80
0.50
182.0
11.5ingle, SHGC=0.6
W
10.0
5.0
15.0
44.35
0.43
283.0
12.Single, SHGC=0.6
E
10.0
5.0
15.0
49.38
0.40
296.0
13.Single, SHGC=0.6
N
1.0
5.0
22.5
22.38
0.96
484.0
14.8ingle, SHGC-0.6
NE
1.0
7.0
35.0
35.89
0.98
1236.0
15.Single, SHGC=0.6
E
1.0
2.0
10.0
49.38
0.74
363.0
16.Single, SHGC=0.6
E
1.0
2.0
4.0
49.38
0.74
145.0
17.Single, SHGC=0.6
W
1.0
4.0
20.0
44.35
0.92
811.0
18.Single, SHGC=0.6
N
1.0
5.0
22.5
22.38
0.96
484.0
19.Single, SHGC=0.6
E
1.0
4.5
18.0
49.38
0.94
831.0
20.Single, SHGC=0.6
E
1.0
5.0
22.5
49.38
0.95
1055.0
21.Single, SHGC=0.6
S
1.0
7.0
35.0
36.80
0.97
1246.0
22.Single, SHGC=0.6
W
1.0
5.0
45.0
44.35
0.95
1895.0
As -Built Total:
466.0
16617.0
WALL TYPES
Area X BSPM = Points
Type
R-Value
Area
X SPM =
Points
Adjacent
61.0 0.70 42.7
1. Concrete, Int Insul, Exterior
7.5
1813.9
0.75
1360.4
Exterior
1813.9 1.90 3446.4
2. Frame, Wood, Adjacent
11.0
61.0
0.70
42.7
Base Total:
1874.9 3489.1
As -Built Total:
1874.9
1403.1
DOOR TYPES
Area X BSPM = Points
Type
Area
X SPM =
Points
Adjacent
0.0 0.00 0.0
1.Extedor Wood
21.0
7.20
151.2
Exterior
56.0 4.80 268.8
2.Exterior Insulated.
35.0
4.80
168.0
Base Total:
56.0 268.8
As -Built Total:
56.0
319.2
EnergyGauge® DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLR
FORM 60OA-2004R EnergyGaugeO 4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , Ft. Pierce, FL, PERMIT #:
BASE
AS -BUILT
CEILING TYPES Area X
BSPM = Points
Type (white Root)
R-Value Area X SPM X SCM = Points
Under Attic
1106.0
2.13 2355.8
1. Under Attic
30.0 1106.0 2.13 X 0.55
1295.7
Base Total:
1106.0
2355.8
As -Built Total:
1106.0
1295.7
FLOOR TYPES
Area X
BSPM = Points
Type
R Value Area X SPM
= Points
Slab
125.0(p)
-31.8-3975.0
1. Slab -On -Grade Edge Insulation 0.0 125.0(p -31.90
-3987.5
Raised
0.0
0.00 0.0
Base Total:
-3975.0
As -Built Total:
125.0
-3987.5
INFILTRATION
Area X
BSPM = Points
Area X SPM
= Points
2035.0
14.31 29120.9
2035.0 14.31
29120.9
Summer Base Points: 40178.5
Summer As -Built Points:
44668.4
Total Summer X System
= Cooling
Total X Cap
X Duct X System X Credit =
Cooling
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Central Unit 42000btuh ,SEER/EFF(15.0) DuctsAtt(S),Con(R),Att(AH),R6.0(INS)
44668 1.00
(1.04 x 1.150 x 1.10) 0.227 0.857
11498.1
40178.5
0.3260 13068.0
44668.4 1.00
1.321 0.227 0.857
11498.1
"Em
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FL v, 5L t':
FORM 60OA-2004R EnergyGauge® 4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
r
ADDRESS: , Ft. Pierce, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM = Points
Overhang
Floor Area
Type/SC
Ornt
Len
Hgt
Area X WPM X WOF = Point
.18 2035.0 9.11 3337.0
1.Single, SHGC=0.8
N
1.0
5.0
15.0
15.49
1.00
231.0
2.Single, SHGC=0.6
W
1.0
1.3
7.5
14.00
1.07
112.0
3.Single, SHGC=0.6
E
0.0
0.0
22.5
13.28
1.00
298.0
4.Single, SHGC=0.6
E
1.0
3.0
9.0
13.28
1.03
123.0
5.Single, SHGC=0.6
W
1.0
4.0
24.0
14.00
1.01
339.0
6.Single, SHGC=0.6
W
1.0
5.0
45.0
14.00
1.01
633.0
7.Single, SHGC=0.6
S
8.0
5.0
30.0
11.24
2.14
723.0
8.Single, SHGC=0.6
E
1.0
5.0
15.0
13.28
1.01
201.0
Mingle, SHGC=0.6
E
1.0
5.0
22.5
13.28
1.01
302.0
10.Single, SHGC=0.6
S
10.0
5.0
10.0
11.24
2.22
249.0
11.5ingle, SHGC=0.6
W
10.0
5.0
15.0
14.00
1.11
232.0
12.8ingle, SHGC=0.6
E
10.0
5.0
15.0
13.28
1.28
254.0
13.Single, SHGC=0.6
N
1.0
5.0
22.5
15.49
1.00
347.0
14.Single, SHGC=0.6
NE
1.0
7.0
35.0
15.20
1.00
532.0
15.Single, SHGC=0.6
E
1.0
2.0
10.0
13.28
1.06
140.0
16.Single, SHGC=0.6
E
1.0
2.0
4.0
13.28
1.06
56.0
17.Single, SHGC=0.6
W
1.0
4.0
20.0
14.00
1.01
282.0
18.Single, SHGC=0.6
N
1.0
5.0
22.5
15.49
1.00
347.0
19.Single, SHGC=0.6
E
1.0
4.5
18.0
13.28
1.01
242.0
20.Single, SHGC=0.6
E
1.0
5.0
22.5
13.28
1.01
302.0
21.Single, SHGC=0.6
S
1.0
7.0
35.0
11.24
1.00
393.0
22.Single, SHGC=0.6
W
1.0
5.0
45.0
14.00
1.01
633.0
As -Built Total:
465.0
6971.0
WALL TYPES
Area X BWPM = Points
Type
R Value
Area X WPM =
Points
Adjacent
61.0 1.80 109.8
1. Concrete, Int Insul, Exterior
7.5
1813.9
2.20
3990.6
Exterior
1813.9 2.00 3627.8
2. Frame, Wood, Adjacent
11.0
61.0
1.80
109.8
Base Total:
1874.9 3737.6
As -Built Total:
1874.9
4100.4
DOOR TYPES
Area X BWPM = Points
Type
Area
X WPM =
Points
Adjacent
0.0 0.00 0.0
1.Exterior Wood
21.0
7.60
159.6
Exterior
56.0 5.10 285.6
2.Extedor Insulated
35.0
5.10
178.5
Base Total:
56.0 285.6
As -Built Total:
56.0
338.1
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R F B 4 .20
v4
FORM 60OA-2004R
` , „ a
EnergyGauge® 4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , Ft. Pierce, FL, PERMIT #:
BASE
AS -BUILT
CEILING TYPES Area X BWPM
= Points
Type (White Roof)
R-Value Area X WPM X WCM = Points
Under Attic
1106.0 0.64
707.8
1. Under Attic
30.0 1106.0 0.64 X 1.04
739.0
Base Total:
1106.0
707.8
As -Built Total:
1106.0
739.0
FLOOR TYPES
Area X BWPM = Points
Type
R-Value Area X WPM
= Points
Slab
125.0(p) -1.9
-237.5
1. Slab -On -Grade Edge Insulation 0.0 125.0(p 2.50
312.5
Raised
0.0 0.00
0.0
Base Total:
-237.5
As -Built Total:
125.0
312.5
INFILTRATION
Area X BWPM
= Points
Area X WPM
= Points
2035.0 -0.28
-569.8
2035.0 -0.28
-569.8
Winter Base Points:
7260.7
Winter As -Built Points:
11891.2
Total Winter X
System = Heating
Total X Cap
X Duct X System X Credit
= Heating
Points
Multiplier
Points
Component Ratio
Multiplier Multiplier Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Electric Heat Pump 42000 btuh ,EFF(8.5) Ducts:Att(S),Con(R),Att(AH),R6.0
11891.2 1.000
(1.070 x 1.160 x 1.11) 0.402 0.902
5936.8
7260.7
0.5640
4022.6
11891.2 1.00
1.378 0.402 0.902
6936.8
r
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FL PB J.t F
FORM 60OA-2004R EnergyGauge® 4.5.2
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , Ft. Pierce, FL, PERMIT #:
BASE AS -BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
4 2450.09 9840.0 40.0 0.97 4 1.00 2333.20 1.00 9332.8
As -Built Total: 9332.8
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total
Points Points Points
13068 4022
9840
26920
1 11498
5937 9333 26768
PASS
am
EnergyGaugeTM' DCA Form 600A-2004R EnergyGauge6/FIaRES'2004R FL PB 2
r COPY
FORM. 60OA-2004R EnergyGauge® 4.5.2
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , Ft. Pierce, FL, PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
F1 ROM
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLR FVtLL
a 1 �3
Lot 2f172 Nettles Island
HVAC Load Calculations
for
Civiletto Residence
Lot 2173
Fort Pierce, Florida
E El
CE- j 1 -S� 1 j
-"V/AC
HVAC LADs
Prepared By:
Residential Energy CaVs
Wednesday, December 19, 2007
►, ,
Rhvael- - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Ken Humphrey Lot 2172 Nettles Island
Port Saint Lucie, FL 34983 Page 2
I -Project Report
I General-Project,information %
-Project Title:
Lot 2172 Nettles Island
Designed By:
Back Draft Services
Project Date:
Wednesday, December 05, 2007
Client Name:
Civiletto Residence
Client Address:
Lot 2173
Client City:
Fort Pierce, Florida
Company Name:
Residential Energy Caic's
Design Data -` -
Reference City: Fort Pierce, Florida
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor
Outdoor
Indoor
Indoor
Grains
Dry Bulb
Wet Bulb
Rel.Hum
Dry Bulb
Difference
Winter: 42
0
30
72
3
Summer: 90
78
50
75
61
I -Check Figures` z''
Total Building Supply CFM: 1,405 CFM Per Square ft.: 0.690
Square ft. of Room Area: 2,035 Square ft. Per Ton: 566
Volume (ft3) of Cond. Space: 18,975 Air Turnover Rate (per hour): 4.4
Total Heating Required With Outside Air:
42,017
Btuh
42.017
MBH
Total Sensible Gain:
32,362
Btuh
82
%
Total Latent Gain:
7,260
Btuh
18
%
Total Cooling Required With Outside Air:
39,622
Btuh
3.30
Tons (Based On Sensible + Latent)
3.60
Tons (Based On 75% Sensible Capacity)
Nqtes.,-
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
Rhvac - Residential & Light Commercial HV_AC Loads
Elite Software Development, Inc.
Ken Humphrey
F Lot 2172 Nettles Island
Port Saint Lucie FL 34983
Pa e 3
Miscellaneous Report
:System ,1. Carrier Or.Eduivalent:.: :4 .-, . ; _, Outdoor... Outdoor 5, ::.;.., :-Indoor, .Indoor ;Grains,.
Input.Data, _ ;, � Dry
Bulb
�� .Wet_B6b� ReLHum. Dry,Bulb Difference
Winter:
42
0 30 72 3.44
Summer:
90
78 50 75 61.09
[-Duct-Sizing Inputs
Main Trunk
Runouts
Calculate: Yes
Yes
Use Schedule: Yes
Yes
Roughness Factor: 0.00300
0.01000
Pressure Drop: 0.1000 in.wg./100 ft.
0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min
450 ft./min
Maximum Velocity: 900 ft./min
750 ft./min
Minimum Height: 0 in.
0 in.
Maximum Height: 0 in.
0 in.
Outside--Air-Data _
_ �. ✓ `x;, a r.. —. .t
Winter
Summer
Infiltration: 0.130 AC/hr
0.070 AC/hr
Above Grade Volume: X 18,975 Cu.ft.
X 18,975 Cu.ft.
2,467 Cu.ft./hr
1,328 Cu.ft./hr
X 0.0167
X 0.0167
Total Building Infiltration: 41 CFM
22 CFM
Total Building Ventilation: 90 CFM
90 CFM
---System 1---
Infiltration & Ventilation Sensible Gain Multiplier:
16.49
= (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier:
41.50
= (0.68 X 0.999 X 61.09 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier:
32.97
= (1.10 X 0.999 X 30.00 Winter Temp. Difference)
Duct,,Load:Factor--Scenanos,for4System:1- :,.,.,=-
,Attic
Q t. Duct From
0,1_Type `Description;; ,n Locatto_ri t
4 ..- :
...,.Surface.'
Ceifin Leaka e_ Insulation Area. , MDD
tg �. :f z.� .... 9
1 Supply Main Attic
16B
0.12 6 550 No
1 Return Main Attic
16B
0.24 6 102 No
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Ken Humphrey Lot 2172 Nettles Island
Port Saint Lucie, FL 34983 ° Pa e 4
Load Preview
I Has Net I2e'c ft Z i _ $en 1 Laf " y Net Sen Sy9 �L:�As
Scope f AED Tong Ton' /Toff Area j: Gain Gain �i. ` Gain "Loss { Size
CFM 1- CFMM
Building
3.30; 3.601 566 2,035'1
32,3621
7,260�
39,622!
42,017;
5081 1,405',
1,405,
-System 1
No 3.30, 3.60 566, 2,035
32,362
7,260•
39,622
42,017•
508
1,405
12x20
Ventilation
-
-
1,484.
3,735
-
5,219!
2,96T
-
- - J-
Duct Latent
2,106
2,106,
Zone 1
929;
20,393
976
21,369
23,316
303'
928
12x14
1-Bedroom 4
- -- -
173
- -
2,189;
313.
2,502
- -- -----
4,107
53;_
100
1-6
2-Golf Cart Room
100,
1_,962'
79'
2_ ,_041;
3,302
-
43 ®
89
1-6
- -
-
0
- - 9'
1-',
- - -
0.-
--
0-0
4-Bath 2
- - 63
., 90
O'
104'
24,
4
120
754
_
5
1-4
5-Stairway
-
1 48'
-
6_41;
- -
38'
679.
-`
1,260
16.,_
291
1-4
6-IGVg chen
•
'
134
1-7
252'
9,051'
115,
9,166'
7,836.
�_
102
41212 ',
4-6
- - - -- -
8-Nook
- - -,
60
3,511,
72
3,583'
4,370
----
5.7
Zone 2
1,106'
18,416
443,
18,859'
15,733.
205 ®
838
10x16
9-Bedroom 3
229
3,375'
139
3,514
4,833:
63_
154,
1-7
10-Bath 3
59,
311'
17;
328
427
6',_
14
1-4
11-Hall2
98,
153,
0
153
124
2!M
7
1-4
- -
12-Stairway
-- -
64
2,708'
51
2,759
1,356
_
-18 -
-
123�
-
1-7
13-Bedroom 2
_ -
144
1,232,
34
_
1,266
1,559
20
56
1-4
14-Master Bath
117,
1,005
28
1,033
1,257
16'
46
1-4
15-Laundry
31
173,
^ 17
190
322'
_
4.
&
1-4
16-Walk In Closet
112.
425
57
482•
794
10;
19
1-4
17-Master Bedroom
252
9,033;
100.
9,133
5,060;
66I®
411:
4-6
Sum of room airflows may be greater than system airflow because
system has multiale zones.
e S-•^ r ti �1r tF a to
Rhvae - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Ken Humphrey Lot 2172 Nettles Island
Port Saint Lucie, FL 34983 Page 5
Total Building Summary Loads
Component,. '" Area -
Sen.
y -.Lat.
_ Sen.;
r ;Total..
.Description �. f _
,Quan
Loss
Gain
Gain.y,
.,-Gain
1A-hb-o: Glazing -Single pane, operable window, heat-
15
486
0
294
294
absorbing, metal frame with break, outdoor insect
screen with 50% coverage, light color closed blinds
with 50% coverage, u-value 1.08
1A-hb-o: Glazing -Single pane, operable window, heat-
7.8
250
0
246
246
absorbing, metal frame with break, outdoor insect
screen with 50% coverage, light color closed blinds
with 50% coverage, u-value 1.07
1A-hb-o: Glazing -Single pane, operable window, heat-
40.5
1,300
0
2,818
2,818
absorbing, metal frame with break, u-value 1.07
7A-1: Glazing -Glass or plastic block, smooth or wide ribs
9
162
0
522
522
or flutes, no screen, no coating, u-value 0.6
IA-hb-o: Glazing -Single pane, operable window, heat-
325
10,434
0
11,934
11,934
absorbing, metal frame with break, outdoor insect
screen with 50% coverage, light color blinds at 450
with 50% coverage, u-value 1.07
1A-hm-o: Glazing -Single pane, operable window, heat-
35
1,334
0
1,548
1,548
absorbing, metal frame no break, outdoor insect
screen with 50% coverage, light color blinds at 450
with 50% coverage, u-value 1.27
1A-hm-o: Glazing -Single pane, operable window, heat-
10
381
0
477
477
absorbing, metal frame no break, light color blinds at
460 with 60% coverage, u-value 1.27
1A-hm-o: Glazing -Single pane, operable window, heat-
35
666
0
666
666
absorbing, metal frame no break, outdoor insect
screen with 50% coverage, light color blinds at 450
with 50% coverage, in partition wall, u-value 1.27
11 N: Door -Metal - Polystyrene Core
35
368
0
318
318
11 D: Door -Wood - Solid Core
21
246
0
213
213
13A-7.5ocs: Wall -Block, board insulation only, R-7.5
1655.2
4,718
0
2,093
2,093
board insulation, open core, siding finish
13A7.5ocs: Wall-
158.7
681
0
347
347
12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity,
61
88
0
88
88
no board insulation, siding finish, wood studs
16C-30: Roof/Ceiling-Under attic or knee wall, Vented
1105.8
1,061
0
1,415
1,415
Attic, No Radiant Barrier, White or Light Color
Shingles, Any Wood Shake, Light Metal, Tar and
Gravel or Membrane, R-30 insulation
22A-ph: Floor -Slab on grade, No edge insulation, no
149
6,071
0
0
0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure:
28,246
0
22,979
22,979
People:
1
200
230
430
Equipment:
300
300
600
Lighting:
0
0
0
Ductwork:
9,447
2,106
6,866
8,971
Infiltration: Winter CFM: 41, Summer CFM: 22
1,356
919
365
1,284
Ventilation: Winter CFM: 90, Summer CFM: 90
2,967
3,735
1,484
5,219
AED Excursion:
0
0
139
139
Total Building Load Totals: 42,017 7,260 32,362 39,622
Check Figures'
Total Building Supply CFM: 1,405 CFM Per Square ft.: 0.690
Square ft. of Room Area: 2,035 Square ft. Per Ton: 566
Volume (ft) of Cond. Space: 18,975 Air Turnover Rate (per hour): 4.4
Rhva6 - Residential & Light Commercial HVAC Loads
Ken Humphrey
iNk
Elite Software Development, Inc.
Lot 2172 Nettles Island
Port Saint Lucia, FL 34983
Page 6
1Total Building Summary Loads (contd)
J,Buildifig,Loads - 7.
.Total Heating Required With Outside Air: 42,017
Btuh
42.017
MBH
Total Sensible Gain: 32,362
Btuh
82
%
Total Latent Gain: 7,260
Btuh
18
%
Total Cooling Required With Outside Air: 39,622
Btuh
3.30
Tons (Based On Sensible + Latent)
3.60
Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may
vary.
Be sure to select a unit that meets both sensible and latent loads.
E3
I
U
n 0V
101- 1A -1P
A& RIA. 11,11 a. h Pi,
0
lkhva'c-Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Ken Humphrey Lot 2172 Netfles Island
Port Saint Lucia, FL 34983 W Page 7
System I Carrier Or Equivalent Summary Loads
Component
;Area,,
Sen: Lat.
-,Sen,Total
Description-.:
Gain
.,,-,-Gain..
Gain
1A-hb-o: Glazing -Single pane, operable window, heat-
15
486
0
294
294
absorbing, metal frame with break, outdoor insect
screen with 50% coverage, light color closed blinds
with 50% coverage, u-value 1.08
IA-hb-o: Glazing -Single pane, operable window, heat-
7.8
250
0
246
246
absorbing, metal frame with break, outdoor insect
screen with 50% coverage, light color closed blinds
with 50% coverage, u-value 1.07
1A-hb-o: Glazing -Single pane, operable window, heat-
40.5
1,300
0
2,818
2,818
absorbing, metal frame with break, u-value 1.07
7A-1 , Glazing -Glass or plastic block, smooth or wide ribs
9
162
0
522
522
or flutes, no screen, no coating, u-value 0.6
1A-hb-o: Glazing -Single pane, operable window, heat-
325
10,434
0
11,934
11,934
absorbing, metal frame with break, outdoor insect
screen with 50% coverage, light color blinds at 450
with 50% coverage, u-value 1.07
IA-hm-o: Glazing -Single pane, operable window, heat-
35
1,334
0
1,548
1,548
absorbing, metal frame no break, outdoor insect
screen with 50% coverage, light color blinds at 450
with 50% coverage, u-value 1.27
1A-hm-o: Glazing -Single pane, operable window, heat-
10
381
0
477
477
absorbing, metal frame no break, light color blinds at
450 with 50% coverage, u-value 1.27
1A-hm-o: Glazing -Single pane, operable window, heat-
35
666
0
666
666
absorbing, metal frame no break, outdoor insect
screen with 50% coverage, light color blinds at 450
with 50% coverage, in partition wall, u-value 1.27
11 N: Door -Metal - Polystyrene Core
35
368
0
318
318
11 D: Door -Wood - Solid Core
21
246
0
213
213
13A-7.5ocs: Wall -Block, board insulation only, R-7.5
1655.2
4,718
0
2,093
2,093
board insulation, open core, siding finish
13A7.5ocs: Wall-
158.7
681
0
347
347
1213-0sw: Part -Frame, R-1 1 insulation in 2 x 4 stud cavity,
61
88
0
88
88
no board insulation, siding finish, wood studs
16C-30: Roof/Ceiling-Under attic or knee wall, Vented
1105.8
1,061
0
1,415
1,415
Attic, No Radiant Barrier, White or Light Color
Shingles, Any Wood Shake, Light Metal, Tar and
Gravel or Membrane, R-30 insulation
22A-ph: Floor -Slab on grade, No edge insulation, no
149
6,071
0
0
0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure:
28,246
0
22,979
22,979
People:
1
200
230
430
Equipment:
300
300
600
Lighting:
0
0
0
Ductwork:
9,447
2,106
6,866
8,971
Infiltration: Winter CFM: 41, Summer CFM: 22
1,356
919
365
1,284
Ventilation: Winter CFM: 90, Summer CFM: 90
2,967
3,735
1,484
5,219
AED Excursion:
0
0
139
139
System 1 Carrier Or Equivalent Load Totals:
42,017
7,260
32,362
39,622
I'Phock'Fig'4r6s,-
Supply CFM: 1,405 CFM Per Square ft.: 0.690
Square ft. of Room Area: 2,035 Square ft. Per Ton: 566
Volume (fF) of Cond. Space: 18,975 Air Turnover Rate (per hour): 4.4
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Ken Humphrey Lot 2172 Nettles Island
Port Saint Lucie FL 34983 Page 8
System 1 Carrier Or Equivalent Summary Loads (cont'd)
System Loads,.
-Total Heating Required With Outside Air:
42,017
Btuh
42.017
MBH
Total Sensible Gain:
32,362
Btuh
82
%
Total Latent Gain:
7,260
Btuh
18
%
Total Cooling Required With Outside Air:
39,622
Btuh
3.30
Tons (Based On Sensible + Latent)
3.60
Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
F I L 'L"� 1 �" Copyr
Rhvac - Residential & Light Commercial HVAC Loads
AL'N",
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucie, FL 34983 MW
Page 9
System 1, Zone I Summary Loads (Peak Load Procedure for Rooms)
Component.,
-Are. Sen
----
Total, Total,,
.,Description
Quan LossGain', .,-.,,..,Gain.
Gain
1A-hb-o: Glazing -Single pane, operable window, heat-
15 486 0
294
294
absorbing, metal frame with break, outdoor insect
screen with 50% coverage, light color closed blinds
with 50% coverage, u-value 1.08
1A-hb-o: Glazing -Single pane, operable window, heat-
7.8 250 0
246
246
absorbing, metal frame with break, outdoor insect
screen with 50% coverage, light color closed blinds
with 50% coverage, u-value 1.07
1A-hb-o: Glazing -Single pane, operable window, heat-
22.5 722 0
1,659
1,659
absorbing, metal frame with break, u-value 1.07
7A-1: Glazing -Glass or plastic block, smooth or wide ribs
9 162 0
522
522
or flutes, no screen, no coating, u-value 0.6
1A-hb-o: Glazing -Single pane, operable window, heat-
190.5 6,118 0
6,708
6,708
absorbing, metal frame with break, outdoor insect
screen with 50% coverage, light color blinds at 45*
with 50% coverage, u-value 1.07
11 N: Door -Metal - Polystyrene Core
35 368 0
318
318
11 D: Door -Wood - Solid Core
21 246 0
213
213
13A-7.5ocs: Wall -Block,. board insulation only, R-7.5
894.8 2,551 0
1,131
1,131
board insulation, open core, siding finish
22A-ph: Floor -Slab on grade, No edge insulation, no
149 6,071 0
0
0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure:
16,974 0
15,994
15,994
People:
1 200
230
430
Equipment:
300
300
600
Lighting:
0
0
0
Ductwork:
5,641 0
3,608
3,608
Infiltration: Winter CFM: 21, Summer CFM: 11
701 476
188
664
System 1, Zone 1 Load Totals:
23,316 976
20,393
21,369
1,Check,jFigures.
Supply CFM: 928
CFM Per Square ft.:
0.999
Square ft. of Room Area: 929
Square ft. Per Ton:
502
Volume (ft') of Cond. Space: 7,586
Air Turnover Rate (per hour):
7.3
Total Heating Required: 23,316 Btuh
23.316 MBH
Total Sensible Gain: 20,393 Btuh
95 %
Total Latent Gain: 976 Btuh
5 %
Total Cooling Required: 21,369 Btuh
1.78 Tons (Based On Sensible + Latent)
1.85 Tons (Based On 75% Sensible Capacity)
[Nbtee'
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
r M I I r,
Rhvac - Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucie FL 34983
Page 10
System 1, Zone 2 Summary Loads ((Peak Load Procedure for Rooms)
Component.
.Area, .. Sen Lat . _'
Sen.Total
-Description
Quan-, Loss . ,Gain ;Gain
Gain.
1A-hb-o: Glazing -Single pane, operable window, heat-
134.5 4,316 0
5,226
59226
absorbing, metal frame with break, outdoor insect
screen with 50% coverage, light color blinds at 45°
with 50% coverage, u-value 1.07
1A-hm-o: Glazing -Single pane, operable window, heat-
35 1,334 0
1,548
1,548
absorbing, metal frame no break, outdoor insect
screen with 50% coverage, light color blinds at 450
with 50% coverage, u-value 1.27
1A-hm-o: Glazing -Single pane, operable window, heat-
10 381 0
477
477
absorbing, metal frame no break, light color blinds at
450 with 50% coverage, u-value 1.27
1A-hb-o: Glazing -Single pane, operable window, heat-
18 578 0
1,159
1,159
absorbing, metal frame with break, u-value 1.07
1A-hm-o: Glazing -Single pane, operable window, heat-
35 666 0
666
666
absorbing, metal frame no break, outdoor insect
screen with 50% coverage, light color blinds at 45°
with 50% coverage, in partition wall, u-value 1.27
13A-7.5ocs: Wall -Block, board insulation only, R-7.5
760.4 2,167 0
962
962
board insulation, open core, siding finish
13A7.5ocs: Wall-
168.7 681 0
347
347
12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity,
61 88 0
88
88
no board insulation, siding finish, wood studs
16C-30: Roof/Ceiling-Under attic or knee wall, Vented
1105.8 1,061 0
1,415
1,415
Attic, No Radiant Barrier, White or Light Color
Shingles, Any Wood Shake, Light Metal, Tar and
Gravel or Membrane, R-30 insulation
Subtotals for structure:
11,272 0
14,915
14,915
People:
0 0
0
0
Equipment:
0
0
0
Lighting:
0
0
0
Ductwork:
3,806 0
3,258
3,258
Infiltration: Winter CFM: 20, Summer CFM: 11
655 443
177
620
System 1, Zone 2 Load Totals:
15,733 443
18,416
18,859
Check Figures • , s.
Supply CFM: 838
CFM Per Square ft.:
0.758
Square ft. of Room Area: 1,106
Square ft. Per Ton:
690
Volume (ft') of Cond. Space: 11,389
Air Turnover Rate (per hour):
4.4
Total Heating Required: 15,733
Btuh 15.733 MBH
Total Sensible Gain: 18,416
Btuh 98 %
Total Latent Gain: 443
Btuh 2 %
Total Cooling Required: 18,859
Btuh 1.57 Tons (Based On Sensible + Latent)
1.60 Tons (Based On 75% Sensible Capacity)
Notes h
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent
loads.
gm—,�� fE4%ONVI
Rhvac - Residential & Light Commercial H VAC Loads
Elite Software Development, Inc.
Ken Humphrey
14110-N
Lot 2172 Nettles Island
Port Saint Lucie, FL 34983
AV
Page 11
I'Detailed Room Loads - Room 1 - Bedroom 4 (Peak Fenestration Gain Procedure)
:General.-,.
-Room is in zone 1, which peaks at 5 pm
Calculation Mode:
Htg. & cig.
Occurrences:
1
Room Length:
15.0 ft.
System Number:
I
Room Width:
11.5 ft.
Zone Number:
1
Area:
173.0 sq.ft.
Supply Air:
100 CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
4.3 AC/hr
Volume:
1,380.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
9 CFM
Runout Air:
0 CFM
Percent of Supply.:
10 %
Runout Duct Size:
6 in.
Actual Summer Vent.:
5 CFM
Runout Air Velocity:
507 ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
507 ft./min.
Actual Winter Infil.:
5 CFM
Actual Loss:
0.165 in.wg./l
00 ft.
Actual Summer Infil.:
3 CFM
Item-,
Area
.-U-_
"tg"'
'Sen,1�'�:HTM�
_,CIg,,___. Lat.Sen
Description .�;�_--sQuantiiY-1
,t—Value
- ..,Loss,,.,,
HTM,,,__ .Gain_.-,:
Gaiw
N -Wall-I 3A-7.5ocs 15 X 8
105
0.095
2.9 299
1.3 0
133
W -Wall-1 3A-7.5ocs 20.5 X 8
156.2
0.095
2.9 445
1.3 0
197
N -GIs-IA-hb-o shgc-0.52 10%S
15
1.080
32.4 486
26.9 0
403
W -GIs-lA-hb-o shgc-0.6 7%S
7.8
1.070
32.1 250
100.8 0
786
Floor-22A-ph 36 ft..Per.
36
1.358
40.7 1,467
0.0 0
0
Subtotals for Structure:
2,947
0
1,519
Infil.: Win.: 5.0, Sum.: 2.7
284
0.585 166
0.158 113
45
Ductwork:
994
387
AED Excursion:
8
People: 200 la per, 230 senjper:
1
200
230
Room Totals:
4,107
313
2,189
n PV
1'444�41MIIFO� �=Ml
Rhvac - Residential & Light Commercial HVAC Loads
Ken Humphrey 9 "n=
Elite Software Development, Inc.
Lot 2172 Nettles Island
Port Saint Lucie, FL 34983
Page 12
-Detailed Room Loads - Room 2 - Golf Cart Room (Peak Fenestration Gain
Procedure)
-General- .. r .._ -.,..
... ., .. • • . ..
_ • .. .
. r . .,, .., ._, . _ ,-..
Room is in zone 1, which peaks at 5 pm
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
10.0 ft.
System Number:
1
Room Width:
10.0 ft.
Zone Number:
1
Area:
100.0 sq.ft.
Supply Air:
89 CFM
Ceiling Height:
9.6 ft.
Supply Air Changes:
5.6 AC/hr
Volume:
960.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
8 CFM
Runout Air:
0 CFM
Percent of Supply.:
9 %
Runout Duct Size:
6 in.
Actual Summer Vent.:
5 CFM
Runout Air Velocity:
455 ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
455 ft./min.
Actual Winter Infil.:
4 CFM
Actual Loss:
0.133 in.wg./100 ft.
Actual Summer Infil.:
2 CFM
Item
Area =lJ-
' ' Htg,. Sen
Clg Lat.Sang
-
_ ,
Description;,
, . ' :.
ty
.>-, Quanti Value•
, .. HTM : L'oss :
HTM _: Gain Gain
N -Wall-13A-7.5ocs 10 X 9
90 0.095
2.9 257
1.3 0 114
E -Wall-13A-7.5ocs 12 X 9
50.5 0.095
2.9 144
1.3 0 64
E-Door-11 N 5 X 7
35 0.350
10.5 368
9.1 0 318
E -GIs-1A-hb-o shgc-0.6 0%S
22.5 1.070
32.1 722
48.0 0 1,081
Floor-22A-ph 22 ft..Per.
22 1.358
40.7 896
0.0 0 0
Subtotals for Structure:
2,387
0 1,577
Infil.: Win.: 3.5, Sum.: 1.9
198
0.586 116
0.157 79 31
Ductwork:
799
347
AED Excursion:
7
Room Totals:
3,302
79 1,962
P 111:
r) PV
Rhvac - Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucie FL 34983
mull
Fa a 13
Detailed Room Loads - Room 3 - Hall (Peak Fenestration Gain Procedure)
Room is in zone 1, which peaks at 5 pm
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
15.7
ft.
System Number:
1
Room Width:
4.0
ft.
Zone Number:
1
Area:
63.0
sq.ft.
Supply Air:
0 CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
0.0 AC/hr
Volume:
502.0
cu.ft.
Required Vent.:
0 CFM
Number of Registers:
0
Actual Winter Vent.:
0 CFM
Runout Air:
0
CFM
Percent of Supply.:
0 %
Runout Duct Size:
0
in.
Actual Summer Vent.:
0 CFM
Runout Air Velocity:
0
ft./min.
Percent of Supply:
0 %
Runout Air Velocity:
0
ft./min.
Actual Winter Infil.:
0 CFM
Actual Loss:
0.000
in.wg./100 ft.
Actual Summer Infil.:
0 CFM
Item. -. _
„r ••< .: Area t .: =U-
171t : .. , . ,Sen ,; Clg La, Sen
�
.Description , z
Quantity.. ,Value
_ HTM-;f, Loss_
. HTM � Gain � rz x Gairr
Floor-22A-ph 1 ft..Per.
1 1.358
40.7 41
0.0 0 0
Subtotals for Structure:
41
0 0
Infil.: Win.: 0.0, Sum.: 0.0
0
0 0
0 0 0
Ductwork:
13
0
Room Totals:
54
0 0
��n
PY
Rhvac - Residential 0, Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucie, FL 34983
AV
Page 14
Detailed Room Loads - Room 4 - Bath 2 (Peak Fenestration Gain Procedure)
_ Room is in zone 1, which peaks
at 5 pm
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
12.0
ft.
System Number:
1
Room Width:
7.5
ft.
Zone Number:
1
Area:
90.0
sq.ft.
Supply Air:
5 CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
0.4 AC/hr
Volume:
720.0
cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
2 CFM
Runout Air:
0
CFM
Percent of Supply.:
34 %
Runout Duct Size:
4
in.
Actual Summer Vent.:
0 CFM
Runout Air Velocity:
54
ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
54
ft./min.
Actual Winter Infil.:
1 CFM
Actual Loss:
0.004
in.wg./100 ft.
Actual Summer Infil.:
1 CFM
Item. _ .. ,
; Area,_ -U-
_ .... _Htg ; Sen
Clg Lat ; e Sen.
-Description ._ .
_Quantity • ,Value
.HTM ,Loss.
,; «. HTM ;,Gain;
Gain
W -Wall-13A-7.5ocs 7.5 X 8
60 0.095
2.9 171
1.3 0
76
Floor-22A-ph 8 ft..Per.
8 1.358
40.7 326
0.0 0
0
Subtotals for Structure:
497
0
76
Infil.: Win.: 1.1, Sum.: 0.6
60
0.583 35
0.150 24
9
Ductwork:
170
18
AED Excursion:
0
Room Totals:
702
24
104
P,.
5 Ksm i kF11 �&, W
Rhvac - Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
dal&
Lot 2172 Nettles Island
Port Saint Lucie, FL 34083
mull
I Pa-ge 15
I'Detailed Room Loads - Room 5 - Stairway (Peak Fenestration Gain Procedure)
General
Room is in zone 1, which peaks at 5 pm
Calculation Mode:
Htg. & cIg.
Occurrences:
1
Room Length:
12.0
ft.
System Number:
1
Room Width:
4.0
ft.
Zone Number:
I
Area:
48.0
sq.ft.
Supply Air:
29 CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
4.6 AC/hr
Volume:
384.0
cu.ft.
Required Vent.:
0 CFM
Number of Registers:
I
Actual Winter Vent.:
3 CFM
Runout Air:
0
CFM
Percent of Supply.:
10 %
Runout Duct Size:
4
in.
Actual Summer Vent.:
1 CFM
Runout Air Velocity:
334
ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
334
ft./min.
Actual Winter Infil.:
2 CFM
Actual Loss:
0.128
in.wg./l 00 ft.
Actual Summer Infil.:
1 CFM
Item
Area , - f - , - ,,. 4 --U-
- -,- - i, -, , Sen
-
CIg-- Lat,,,
,Description
"Quantity, Value.
- Los S
HTM, -�,,Gain
E -Wall-1 3A-7.5ocs 12 X 8
87 0.095
2.9 248
1.3 0 110
E -GIs-7A-1 shgc-0.65 0%S (2)
9 0.600
18.0 162
44.4 0 400
Floor-22A-ph 12 ft..Per.
12 1.358
40.7 489
0.0 0 0
Subtotals for Structure:
899
0 510
Infil.: Win.: 1.1, -Sum.: 0.9
96
'0.583 56
0.156 38 15
Ductwork:
305
113
AED Excursion:
2
Room Totals:
1,260
38 641
0 PY
DOW & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
''
Lot 2172 Nettles Island
Port Saint Lucie, FL 34983
Page 16
Detailed Room Loads - Room 6 - Kitchen (Peak Fenestration Gain Procedure)
Genetal,.
Room is in zone 1, which peaks at 5 pm
Calculation Mode:
Htg. & c1g.
Occurrences:
1
Room Length:
13.0
ft.
System Number:
I
Room Width:
11.0
ft.
Zone Number:
I
Area:
143.0
sq.ft.
Supply Air:
134 CFM
Ceiling Height:
8.0
ft.
Supply Air Changes:
7.0 AC/hr
Volume:
1,144.0
cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
4 CFM
Runout Air:
0
CFM
Percent of Supply.:
3 %
Runout Duct Size:
7
in.
Actual Summer Vent.:
7 CFM
Runout Air Velocity:
500
ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
500
ft./min.
Actual Winter Infil.:
2 CFM
Actual Loss:
0.129
in.wg./l 00 ft. Actual Summer Infil.:
1 CFM
Jtem
.9 -..,Sen
Qig,. Lat,
,Description-
_',,:Quantity-, —iValue.-
,-,.HTM Loss-
HTM,-.Gain,-,.-. - Gain.
W -Wall-1 3A-7.5ocs 11 X 8
70
0.095 2.9 200
1.3 0 88
W -GIs-lA-hb-o shgc-0.6 2%S
18
1.070 32.1 578
111.3 0 2,004
Floor-22A-ph 11 ft.. Per.
11
1.358 40.7 448
0.0 0 0
Subtotals for Structure:
1,226
0 2,092
Infil.: Win.: 1.6, Sum.: 0.8
88
0.591 52
0.159 36 14
Ductwork:
408
519
AED Excursion:
11
Equipment:
300 300
Room Totals:
1,686
335 2,936
r) PV
Rhvac -sid Reential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucie, FL 34983
O
Page 17
Detailed Room Loads - Room 7 - Living (Peak Fenestration Gain Procedure)
General.
1.
_Room is in zone 1, which peaks at
5 pm
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
21.0 ft.
System Number:
1
Room Width:
12.0 ft.
Zone Number:
1
Area:
252.0 sq.ft.
Supply Air:
412 CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
12.3 AC/hr
Volume:
2,016.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
4
Actual Winter Vent.:
18 CFM
Runout Air:
0 CFM
Percent of Supply.:
4 %
Runout Duct Size:
6 in.
Actual Summer Vent.:
21 CFM
Runout Air Velocity:
524 ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
524 ft./min.
Actual Winter Infil.:
5 CFM
Actual Loss:
0.176 in.wg./l00 ft.
Actual Summer Infil.:
3 CFM
.. o
:Htg.. , , . Sena
YCIg Lat Sen.
Description
.,---•:Quantity ° -
Value
s: ,HTM . • Loss-,
,.,.:: :HTM , : , • -.Gain Gain'
W -Wall-13A-7.5ocs 12.6 X 8
55.8
0.095
2.9 159
1.3 0 71
S -Wall-13A-7.5ocs 11 X 8
58
0.095
2.9 165
1.3 0 73
E -Wall-13A-7.5ocs 12.6 X 8
42.3
0.095
2.9 121
1.3 0 53
E-Door-11 D 3 X 7
21
0.390
11.7 246
10.1 0 213
W -GIs-lA-hb-o shgc-0.6 2%S (2)
45
1.070
32.1 1,444
111.7 0 5,028
S -GIs-IA-hb-o shgc-0.6 0%S (2)
30
1.070
32.1 964
26.3 0 788
E -GIs-IA-hb-o shgc-0.6 0%S
15
1.070
32.1 482
30.5 0 458
E -GIs-lA-hb-o shgc-0.6 0%S
22.5
1.070
32.1 722
30.5 0 687
Floor-22A-ph 36 ft..Per.
36
1.358
40.7 1,467
0.0 0 0
Subtotals for Structure:
5,770
0 7,371
Infil.: Win.: 5.1, Sum.: 2.8
290
0.587 170
0.159 115 46
Ductwork:
1,896
1,601
AED Excursion:
32
Room Totals:
7,836
115 9,051
���rl
PV
Rhvic -'Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Ida&
Lot 2172 Nettles Island
Port -Saint Lucie, FL 34983
MW
Page 18
Detailed Room Loads - Room 8 - Nook (Peak Fenestration Gain Procedure)
Room is in zone 1, which peaks at 5 pm
Calculation Mode:
Htg. & c1g.
Occurrences:
1
Room Length:
10.0 ft.
System Number.
1
Room Width:
6.0 ft.
Zone Number:
I
Area:
60.0 sq.ft.
Supply Air:
160 CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
20.0 AC/hr
Volume:
480.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
10 CFM
Runout Air:
0 CFM
Percent of Supply.:
6 %
Runout Duct Size:
8 in.
Actual Summer Vent.:
8 CFM
Runout Air Velocity:
458 ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
458 ft./min.
Actual Winter Infil.:
3 CFM
Actual Loss:
0.091 in.wg./I 00 ft.
Actual Summer Infil.:
2 CFM
Item
.Htg
Description,-,
Quantityv1`,,,.,. nValue.
TM& _ .Loss
S -Wall-1 3A-7.5ocs 11 X 8
58 0.095
2.9 165
1.3 0 73
W -Wall-1 3A-7.5ocs 5.5 X 8
29 0.095
2.9 83
1.3 0 37
E -Wall-1 3A-7.5ocs 6 X 8
33 0.095
2.9 94
1.3 0 42
S -GIs-lA-hb-o shgc-0.6 O%S (2)
30 1.070
32.1 964
26.3 0 788
W -GIs-lA-hb-o shgc-0.6 20%S
15 1.070
32.1 482
96.7 0 1,451
E -GIs-1A-hb-o shgc-0.6 O%S
15 1.070
32.1 482
30.5 0 458
Floor-22A-ph 23 ft..Per.
23 1.358
40.7 937
0.0 0 0
Subtotals for Structure:
3,207
0 2,849
Infil.: Win.: 3.2, Sum.: 1.7
180
0.589 106
0.156 72 28
Ductwork:
1,057
621
AED Excursion:
13
Room Totals:
4,370
72 3,511
PV
Rhveic -'Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
LPort Saint Lucia, FL 34983
Page 19
FDetailed Room Loads - Room 9 - Bedroom 3(Pewak Fenestration Gain Procedure)
1,General
-'Room is in zone 2, which peaks at 5 pm
Calculation Mode:
Htg. & c1g.
Occurrences:
1
Room Length:
18.0 ft.
System Number:
1
Room Width:
12.7 ft.
Zone Number:
2
Area:
229.0 sq.ft.
Supply Air:
154 CFM
Ceiling Height:
12.0 ft.
Supply Air Changes:
3.4 AC/hr
Volume:
2,743.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
I
Actual Winter Vent.:
11 CFM
Runout Air.
0 CFM
Percent of Supply.:
7 %
Runout Duct Size:
7 in.
Actual Summer Vent.:
8 CFM
Runout Air Velocity:
575 ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
575 ft./min.
Actual Winter Infil.:
6 CFM
Actual Loss:
0.171 in.wg./100 ft.
Actual Summer Infil.:
3 CFM
Item
-Descrilklon
..Area
Quantity
-Value,-, HTM: Loss,.,,
Gain-- �,;',Gain
E -Wall-1 3A-7.5ocs 12.7 X 10
117
0.096
2.9 333
1.3
0 148
NE-Wall-13A-7.5ocs 7.3 X 8
23.4
0.095
2.9 67
1.3
0 30
N -Wall-1 3A-7.5ocs 14.5 X 8
93.5
0.095
2.9 266
1.3
0 118
W -Wall-1 3A-7.5ocs 6 X 8
48
0.095
2.9 137
1.3
0 61
N -GIs-IA-hb-o shgc-0.6 10%S
22.5
1.070
32.1 722
29.9
0 673
NE-GIs-lA-hm-o shgc-0.6 O%S
(2) 35
1.270
38.1 1,334
29.2
0 1,022
E -GIs-lA-hm-o shgc-0.6 O%S
10
1.270
38.1 381
36.6
0 366
UP-Ceii-16C-30 18 X 12.7
228.6
0.032
1.0 219
1.3
0 293
Subtotals for Structure:
3,459
0 2,711
Infil.: Win.: 6.2, Sum.: 3.3
349
0.587 205
0.157
139 55
Ductwork: -
1,169
597
AED Excursion:
12
Room Totals:
4,833
139 3,375
rw I I Erm
®rlic ArA nV
Rhva'c .'Risidential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucia, FL 34983
Page 20
Detailed Room Loads - Room 10 - Bath 3160eak Fenestration Gain Procedure)
1,Gpneral, r.
Room is in zone 2, which peaks at 5 pm
Calculation Mode:
Htg. & c1g.
Occurrences:
1
Room Length:
10.7
ft.
System Number:
I
Room Width:
5.5
ft.
Zone Number:
2
Area:
59.0
sq.ft.
Supply Air:
14 CFM
Ceiling Height:
10.0
ft.
Supply Air Changes:
1.4 AC/hr
Volume:
589.0
cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
1 CFM
Runout Air.
0
CFM
Percent of Supply.:
7 %
Runout Duct Size:
4
in.
Actual Summer Vent.:
I CFM
Runout Air Velocity:
162
ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
162
ft./min.
Actual Winter Infil.:
1 CFM
Actual Loss:
0.031
in.wg./l 00 ft.
Actual Summer Infil.:
0 CFM
"!t
Are
Ht '§en,"
9
-L-t
Seri -
Description
Quantity��
-Value,
HTM Loss----•
0HTMi, Gain, 2.,,
Gain
E -Wall-1 3A-7.5ocs 5.5 X 8
40 0.095
2.9 114
1.3 0
51
E -GIs-lA-hb-o shgc-0.6 O%S
4 1.070
32.1 128
30.5 0
122
UP-Ceil-16C-30 10.7 X 5.5
58.8 0.032
1.0 56
1.3 0
75
Subtotals for Structure:
298
0
248
Infil.: Win.: 0.8, Sum.: 0.4
44
0.591 26
0.159 17
7
Ductwork:
103
55
AED Excursion:
I
Room Totals:
427
17
311
fl PV
Rhva7c - Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucia, FL 34983
Page 21
Detailed Room Loads - Room 11 - Hag 2 (Peak Fenestration Gain Procedure)
1,General
Room is in zone 2, which peaks at
5 pm
Calculation Mode:
Htg. & c1g.
Occurrences:
Room Length:
24.5
ft.
System Number:
Room Width:
4.0
ft.
Zone Number:
2
Area:
98.0
sq.ft.
Supply Air:
7 CFM
Ceiling Height:
10.0
ft.
Supply Air Changes:
0.4 AC/hr
Volume:
980.0
cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
0 CFM
Runout Air.
0
CFM
Percent of Supply.:
4 %
Runout Duct Size:
4
in.
Actual Summer Vent.:
0 CFM
Runout Air Velocity:
80
ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
80
ft./min.
Actual Winter Infil.:
0 CFM
Actual Loss:
0.008
in.wg./100 ft.
Actual Summer Infil.:
0 CFM
Item,,
Area., - 'TU7
jitg §en
---,-Clg 'La
.Description,
-Quantity',',�.
HTM..;,,,,, Loss �.,HTM ��.,'�.Gain,-: ;--Gain-:
UP-Ceil-1 6C-30 24.6 X 4
98 0.032
1.0 94
1.3 0 125
Subtotals; for Structure:
94
0 125
Infil.: Win.: 0.0, Sum.: 0.0
0
0 0
0 0 0
Ductwork:
30
27
AED Excursion:
1
Room Totals:
124
0 153
rILC
Rhvic-- Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles
Island
Port Saint Lucie, FL 34983
—Page-22
Detailed Room Loads - Room 12 - Stairway (Peak Fenestration Gain Procedure)
General_:.
Room is in zone 2, which peaks at 5 pm
Calculation Mode:
Htg. & c1g.
Occurrences:
1
Room Length:
16.0 ft.
System Number:
1
Room Width:
4.0 ft.
Zone Number:
2
Area:
64.0 sq.ft.
Supply Air:
123 CFM
Ceiling Height:
8.0 ft.
Supply Air Changes:
14.4 AC/hr
Volume:
512.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
3 CFM
Runout Air:
0 CFM
Percent of Supply.:
3 %
Runout Duct Size:
7 in.
Actual Summer Vent.:
6 CFM
Runout Air Velocity:
461 ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
461 ft./min.
Actual Winter Infil.:
2 CFM
Actual Loss:
0.110 in.wg./l 00 ft.
Actual Summer Infil.:
1 CFM
Item , -�
11
j, Area, �U,-'—
Htd, Sen
-CIg,:,,--,:., Lat,
Sen
�,,- Description --j
Quantity. Value
;.HTM Loss
��,,!,,, HTM,-Gain..-
Gain
W -Wall-1 3A-7.5ocs 16 X 8
110 0.095
2.9 314
1.3 0
139
W -GIs-IA-hb-o shgc-0.6 2%S
18 1.070
32.1 578
109.9 0
1,978
UP-Ceil-1 6C-30 16 X 4
64 0.032
1.0 61
1.3 0
82
Subtotals for Structure:
953
0
2,199
Infil.: Win.: 2.3, Sum.: 1.2
128
0.586 75
0.156 51
20
Ductwork:
328
479
AED Excursion:
10
Room Totals:
1,356
51
2,708
C I
PY
Rhvdc -'Itisidential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucia, FL 34983
Page 23
�Detailed Room Loads - Room 13 - Bedroom 2 (Peak Fenestration Gain Procedure)
General.
Room is in zone 2, which peaks at 5 pm
Calculation Mode:
Htg. & c1g.
Occurrences:
1
Room Length:
13.5 ft.
System Number:
1
Room Width:
10.7 ft.
Zone Number:
2
Area:
144.0 sq.ft.
Supply Air:
56 CFM
Ceiling Height:
10.0 ft.
Supply Air Changes:
2.3 AC/hr
Volume:
1,445.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
4 CFM
Runout Air:
0 CFM
Percent of Supply.:
6 %
Runout Duct Size:
4 in.
Actual Summer Vent.:
3 CFM
Runout Air Velocity:
643 ft./min.
Percent of Supply:
6 %
Runout Air Velocity:
643 ft./min.
Actual Winter Infil.:
2 CFM
Actual Loss:
0.464 in.wg./100 ft.
Actual Summer Infil.:
1 CFM
Item
Sen.
,Description
!Quantity. ,Value.
HTM Loss-
HTM, Gain..,,- »Gairi
N -Wall-1 3A7.5ocs 10.7 X 8
63.1 0.143
4.3 271
2.2 0 138
N -GIs-IA-hb-o shgc-0.6 10%S
22.5 1.070
32.1 722
29.9 0 673
UP-Ceii-16C-30 13.5 X 10.7
144.4 0.032
1.0 139
1.3 0 185
Subtotals for Structure:
1,132
0 996
Infil.: Win.: 1.5, Sum.: 0.8
86
0.584 50
0.164 34 14
Ductwork:
377
218
AED Excursion:
4
Room Totals:
1,559
34 1,232
tu
rnPY
Rhvac - Resi ential & Light Commercial
HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucie, FL 34983
Page 24
Detailed Room Loads - Room 14 - Master Bath (Peak Fenestration Gain Procedure)
General ,.: . 5 ,. . _.- >> _, •. -,. ,.. -
,t: - �,
- - <••
Room is in zone 2, which peaks at 5 pm
Calculation Mode:
Htg. & cig.
Occurrences:
1
Room Length:
13.5 ft.
System Number:
1
Room Width:
8.7 ft.
Zone Number:
2
Area:
117.0 sq.ft.
Supply Air:
46 CFM
Ceiling Height:
10.0 ft.
Supply Air Changes:
2.3 AC/hr
Volume:
1,175.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
3 CFM
Runout Air:
0 CFM
Percent of Supply.:
6 %
Runout Duct Size:
4 in.
Actual Summer Vent.:
2 CFM
Runout Air Velocity:
524 ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
524 ft./min.
Actual Winter Infil.:
1 CFM
Actual Loss:
0.310 in.wg./l00
ft. Actual Summer Infil.:
1 CFM
Htg en
S
Cfg , Lat Spn
-
,Description,
Y °> w:G2uantity
Value, 4 • < HTM ;. Lyoss ,
HTM n Gain Gain.
E -Wall-13A7.5ocs 8.7 X 8
51.6
0.143 4.3 221
2.2 0 113
E -GIs-lA-hb-o shgc-0.6 0%S
(2) 18
1.070 32.1 578
30.6 0 550
UP-Ceil-16C-30 13.5 X 8.7
117.4
0.032 1.0 113
1.3 0 150
Subtotals for Structure:
912
0 813
Infil.: Win.: 1.2, Sum.: 0.7
70
0.589 41
0.158 28 11
Ductwork:
304
178
AED Excursion:
4
Room Totals:
1,257
28 1,005
Mir
Rhvac - Resi ential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucie, FL 34983
IV
Page 25
Detailed Room Loads - Room 15 - Laundry (Peak Fenestration Gain Procedure)
General
_ Room is in zone 2, which peaks at 5 pm
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
6.1 ft.
System Number:
1
Room Width:
5.0 ft.
Zone Number:
2
Area:
31.0 sq.ft.
Supply Air:
8 CFM
Ceiling Height:
10.0 ft.
Supply Air Changes:
1.6 AC/hr
Volume:
305.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
1
Actual Winter Vent.:
1 CFM
Runout Air:
0 CFM
Percent of Supply.:
9 %
Runout Duct Size:
4 in.
Actual Summer Vent.:
0 CFM
Runout Air Velocity:
90 ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
90 ft./min.
Actual Winter Infil.:
1 CFM
Actual Loss:
0.010 in.wg./100 ft.
Actual Summer Infil.:
0 CFM
Item
Area. -U-
.. �Htg.: Sen. _
CIg: �,._ Lat, Sep;
.:-
Description. ,:
P
15.5
� uanti Value,:..:
Q tY
<-HTW.?. Loss � _ : .
,. HTM, : -- - Gain Gain
W -Wall-13A7.5ocs X 8
44 0.143
4.3 189
2.2 0 96
UP-Ceil-16C-30 6.1 X 5
30.5 0.032
1.0 29
1.3 0 39
Subtotals for Structure:
218
0 135
Infil.: Win.: 0.8, Sum.: 0.4
44
0.591 26
0.159 17 7
Ductwork:
78
31
AED Excursion:
1
Room Totals:
322
17 173
I ivCK,
f V"', n Dv
a„ -
Rhvac - Resi ential & Light Commercial HVAC Loads Elite Software Development, Im
Ken Humphrey Lot 2172 Nettles Islan
Port Saint Lucie, FL 34983 Page 2
Detailed Room Loads - Room 16 - Walk In Closet (Peak Fenestration Gain
Procedure)
Room is in zone 2, which peaks at 5 pm
Calculation Mode:
Htg. & clg.
Occurrences:
1
Room Length:
14.0 ft.
System Number:
1
Room Width:
8.0 ft.
Zone Number:
2
Area:
112.0 sq.ft.
Supply Air:
19
CFM
Ceiling Height:
10.0 ft.
Supply Air Changes:
1.0
AC/hr
Volume:
1,120.0 cu.ft.
Required Vent.:
0
CFM
Number of Registers:
1
Actual Winter Vent.:
2
CFM
Runout Air:
0 CFM
Percent of Supply.:
9
%
Runout Duct Size:
4 in.
Actual Summer Vent.:
1
CFM
Runout Air Velocity:
221 ft./min.
Percent of Supply:
5
%
Runout Air Velocity:
221 ft./min.
Actual Winter Infil.:
3
CFM
Actual Loss:
0.057 in.wg./100
ft.
Actual Summer Infil.:
1
CFM
Item
Area
-U-
`Htg Sen.
Cl NLat
Sen
Description _ . , _.,,
._,
ty
..`,` Quanti _, ;,,
,Value`;
HTMti Loss
,
;,_HTM,-
n
Gain Gain.
E -Wall-13A-7.5ocs 14 X 8
112
0.095
2.9 319
1.3
0
142
S -Wall-13A 7.5ocs 4 X 8
32
0.095
2.9 91
1.3
0
40
UP-Ceil-16C-30 14 X 8
112
0.032
1.0 108
1.3
0
143
Subtotals for Structure: 518 0 325
Infil.: Win.: 2.6, Sum.: 1.4 144 0.583 84 0.160 57 23
Ductwork: 192 75
AED Excursion: 2
Room Totals: 794 57 425
RhvTc -.' R6 sibential & Light Commercial
HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucia, FL 34983
FNe 27
Detailed Room Loads - Room 17 - Master Bedroom (Peak Fenestration Gain
Procedure)
-Gefi6r,'61
Room is in zone 2, which peaks at i- pm'
Calculation Mode:
Htg. & c1g.
Occurrences:
1
Room Length:
18.0 ft.
System Number:
1
Room Width:
14.0 ft.
Zone Number:
2
Area:
252.0 sq.ft.
Supply Air:
411 CFM
Ceiling Height:
10.0 ft.
Supply Air Changes:
9.8 AC/hr
Volume:
2,520.0 cu.ft.
Required Vent.:
0 CFM
Number of Registers:
4
Actual Winter Vent.:
12 CFM
Runout Air:
0 CFM
Percent of Supply.:
3 %
Runout Duct Size:
6 in.
Actual Summer Vent.:
21 CFM
Runout Air Velocity:
523 ft./min.
Percent of Supply:
5 %
Runout Air Velocity:
523 ft./min.
Actual Winter Infil.:
4 CFM
Actual Loss:
0.175 in.wg./l 00 ft.
Actual Summer Infil.:
2 CFM
-'Wrea 513 H_t9' S pv
U t
I.,.'!fe
De§crptior1
Quantity
-
Value-,
TM L
,.
E -Wall-1 3A-7.5ocs 14 X 8
89.5
0.095
2.9 255
1.3 0
113
S -Part-1 5*/15*-1 213-0sw 2 X 8
16
0.097
1.5 23
1.5 0
23
S -Part-1 F/I 5'-1 213-0sw 10 X 8
45
0.097
1.5 65
1.5 0
65
W -Wall-1 3A-7.5ocs 17.5 X 8
95
0.095
2.9 271
1.3 0.
120
E -GIs-IA-hb-o shgc-0.6 O%S
22.5
1.070
32.1 722
30.5 0
687
S -GIs-lA-hm-o in partition (2)
35
1.270
19.1 666
28.7 0
1,004
W -GIs-lA-hb-o shgc-0.6 2%S (2)
45
1.070
32.1 1,444
111.7 0
5,028
UP-Ceil-16C-30 18 X 14
252
0.032
1.0 242
1.3 0
323
Subtotals for Structure:
3,688
0
7,363
Infil.: Win.: 4.5, Sum.: 2.4
252
0.587 148
0.159 100
40
Ductwork:
1,224
1,598
AED Excursion:
32
Room Totals:
5,060
100
9,033
n P'v
......... .........
Rhvk -FRIsMential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Ken Humphrey
Lot 2172 Nettles Island
Port Saint Lucie, FL 34983
Page 28
System I Room Load Summary
Ht Min
M . _
.., Run Run, �r,
Clg,'. r,,,,,qg
Min
ActRoom .
Area--.
Sens, Htg.
_Duct,, ,., Duct,,.;
Sens.,;I, Lat
,.Clg
Name,
SF...-
-.Btuh- ,:CFM,,p"
--Size,'.%;o-VeI-
'Btuh Btuh
CFM," -
F CFM
--Zone 1--
1 Bedroom 4
173
4,107 53
1-6 507
2,189 313
100
100V
2 Golf Cart Room
100
3,302 43
1-6 455
1,962 79
89
89v
3 Hall
63
54 1
0-0 0
0 0
0
0 V
4 Bath 2
90
702 9
1-4 54
104 24
5
5%,
5 Stairway
48
1,260 16
1-4 334
641 38
29
29V
6 Kitchen
143
1,686 22
1-7 500
2,936 335
134
134 w
7 Living
252
7,836 102
4-6 524
9,051 115
412
412"
8 Nook
60
4,370 57
1-8 458
3,511 72
160
160
Zone 1 subtotal
929
23,316 303
20,393 976
928
928
---Zone 2-
9 Bedroom 3
229
4,833 63
1-7 675
3,375 139
154
154✓
10 Bath 3
59
427 6
1-4 162
311 17
14
14-.1
11 Hall 2
98
124 2
1-4 so
153 0
7
7,J
12 Stairway
64
1,356 18
1-7 461
2,708 51
123
12V
13 Bedroom 2
144
1,659 20
1-4 643
1,232 34
56
56t/
14 Master Bath
117
1,257 16
1-4 524
1,005 28
46
46%r
15 Laundry
31
322 4
1-4 90
173 17
8
8..'
16 Walk In Closet
112
794 10
1-4 221
425 57
19
19,/
17 Master Bedroom
252
5,060 66
4-6 523
9,033 100
411
41 1'V
Zone 2 subtotal
1,106
15,733 205
18,416 443
838
838
Ventilation
2,967
1,484 3,735
Duct Latent
2,106
System 1 total
2,036
42,017 608
32,362 7,260
1,406
1,405
System 1 Main Trunk Size:
12x20 in.
Velocity:
843 ft./min
Loss per 100 ft.:
0.094 in.wg
Note: Since the system is multizone,
the Peak Fenestration Gain Procedure was used to determine glass sensible gains
at the room and zone levels,
so the sums of the zone sensible gains and airflows for cooling shown above are not intended
to equal the totals at the system level.
Room and zone sensible gains and cooling
CFM values are for the hour in which
the glass sensible gain for the
zone is at its peak. Sensible
gains at the system level are based on the "Average
Load
Procedure + Excursion" method.
Cooling.,System-Summary,
Cooling
;Sensible/Latent. t
Sensible-
'Latent-
Total,'
Tql.
'50it
Btuh'
Btu h
lit U
Net Required:
3.30
82%/18%
32,362
7,260
39,622
Recommended:
3.60
75%/25%
32,362
10,787
43,150
Actual:
3.60
76%/24%
31,900
10,100
42,000
jEquipment Data ,_,-�4^
S'
Heating System
Cooling System
Type:
CENTRAL UNIT
CENTRAL UNIT
Model:
25HCA342A003 OR EQUIVALENT
FV413NF005 OR EQUIVALENT
Brand:
CARRIER
CARRIER
Description:
HEAT PUMP
AIR HANDLER
Efficiency:
HSPF 8.5
15 SEER
Sound:
Capacity:
42K BTU
42K BTU
Sensible Capacity:
n/a
31,900 Btuh
Latent Capacity:
n/a
10,100 Btuh
r. I
Code Compliance Division Review Comments
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522 Page 1
hftp://stiucieco.gov/ce
PROPERTY INFORMATION Owner(s):
Address: 2173 NETTLES BLVD
Charles Civiletto
City / State / Zip; JENSEN BEACH FL 34957
Parcel # : 4502-501-0176-000/5 Jurisdiction: St. Lucie County
Zoning: HIRD Lot # : Block:
APPLICATION INFORMATION
Permit Number: 0804-0159 Application Type: Master Permit w/subs
Activity Type: New Other Activity:
Permit Type: Building Residential (SFR) Stories: 1 Automatic Sprinkler System?
CONTRACTOR INFORMATION
Contractor Name: NEWMAN JAMES W Fax Number 772-232-17X' /
Business Name: JWN CONSTRUCTION INC
Business Addr: 1036 NE JENSEN BEACH BLVD
City / State / Zil JENSEN BEACH, FL 349
REVIEWS AND COMMENTS
Review Type Status Reviewed By Date Started Date Complete Date Released
Documents Missing Pending Lorie Gerstemeier
04/15/2008 1 Comment need noc at time of pickup
04/15/2008 2 Comment BEFORE ISSUING THIS PERMIT #97050126 NEED VOID LETTER FOR GLASS ROOM AND THAT
THEY DEMO THE TRAILER AND REPLACED IT WITH NEW SFR
04/17/2008 3 Comment PLUMBING SUB IS ON HOLD. PLEASE CONTACT CONTRACTOR LICENSING AT 462-1672
Front Counter Review Complete
Plans Examiner Review Incomplete
Lorie Gerstemeier 04/15/2008 04/15/2008
Kathy Clcio F04/l/L
E kme lt� Py
04/18/2008 1 Comment BOTH SETS OF FLOOR & ROOF TRUSS PLANS MUST BE SIGNED THAT THEY WERE "REVIEWED
& APPROVED" BY ENGINEER OF RECORD PAUL WELCH
04/18/2008 2 Comment METAL ROOF FASTENING NOTE ON BOTH TYPICAL WALL SECTIONS ON PAGE A-4 OF PLANS
QUOTE FBC 2001 EDITION - WE ARE CURRENTY UNDER THE GUIDELINES OF FBC 2004 EDITION
- PLEASE CORRECT
**NOTE**
FBC 2007 GOES INTO EFFECT OCTOBER 1, 2008
04/18/2008 3 Comment NEGATIVE DESIGN PRESSURES FOR WINDOWS #1,0 5,018 and ARE TOO LOW FOR ZONE
5 @ 140mph, USING EXPOSURE "C" MULTIPLIER OF 1.35 FOR MEANIROOF HEIGHT OF 25'
Zoning Review Complete
Jodee Vorreyer 04/17/2008 04/17/2008
i.
s
• TRANSMISSION VERIFICATION REPORT
TIME 04/18/2008 09:09
NAME
FAX 4622885
TEL
SER.* BROM5J411427
DATE,TIME
04/18 09:09
FAX NO./NAME
917722321744
DURATION
00:00:23
PAGE(S)
01
RESULT
OK
MODE
STANDARD
ECM
code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-9553 Fax: (772) 462-2922
trttp:llstiucieco.govlcp
PROPERTY INFORMATION
Address: 2173 NETTLES BIND
City I State / Zip; J ENSEN BEACH
Parcel # : 4502-801-0178-00015
Zoning: HIRD
APPLICATION INFORMATION
Permit Number: 0804-0159
Activity Type: New
Permit Typo: Building Residentlal (SFR)
Review Comments
FL 34957
Jurisdiction: St, Lucie County
tat # : Block:
CONTRACTOR INFORMATION
Contractor Name: NEWMAN JAMES W
Business Name: JWN CONSTRUCTION ING
Gusiness Addr: 1036 NE JENSEN BEACH BLVD
Page 1
Owner(s):
Charles Civiletto
Application Type: Master Permit wlsubs
Other Activity:
Stories: 1 Automatic Sprinkler System? U
Fax Number 772-232-17
1741-f
city I state I Zil ,]ENSEN BEACH, FL 349.
VIEWS AND COMMENTS
Review Type ALkwS Reviewed By
Documents Missing Pending Lurie Gerstemeler
Dale Started Date Complete Date_Rel$�d
04115/2008 1 Comment need noc at time of pickup
04/15/2008 2 Comment BEFORE ISSUING THIS PERMIT #87050126 NEED VOID LETTER FOR GLASS ROOM AND THAT
r OFFICE USE ONLY:
DATE FILED: 0 A
REVISION FEE:
PERMIT
RECEIPT NO.: LQ' 0SR l 3�.
ST. LUCIE COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
BUILDING & ZONING
2300 VIRGINIA AVE►
FORT PIERCE, FL 3498,1
•462-1553 .
.APPLICATION FOR BUILDING P
PROJECT INFORMATION
1. LOCATION!S
ADDRESS: i
2. DETAILED DESCRIPTION'S OF PROJECT
REVISIONS: �'�%� -
3.- CON'TRACTOR INFORMATION:
ST. OF FL REGJCERT#
BUSINESS NAME: ` �44') t/
Qualifiers Name:
a►DDRESS:
CITY:
PHONE (DaYTINIE):
4. ARCHIT/tNGItiEER:
e/--ej� Al
DAME:
ADDRESS:
CITY: bf%yif�L
PHONE (DAYTIME): ?7 Z.- 77,;W
ST. LUCIE COUNTY CERT.-M / Q 7" 16-
r-Axu
r
y
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
http://stiucleco.gov/ce
Date:
10 June 2008
Job Address:
2173 NETTLES BLVD
Received By:
gerstemi
Paid With:
CK
Paid By: JWN CONSTRUCTION INC
Building
Receipt
Sign:
Receipt4:
0000063213
'ermit Number:
SLC- 0804-0159
Amount:
$50.00
-redit Card Number:
Check Number:
9060
I