HomeMy WebLinkAboutSUBMITTED PAPERS_2r FORM-60OA-2004R EnergyGauge® 4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION . Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Civiletto Residence Builder: Address: A>7�3 Alb WPl NW Permitting Office: St. Lucie Coun City, State: Ft. Pierce, FL Permit Number: Owner. Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 2. Single family or multi -family Single family _ 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 4 _ 5. Is this a worst case? Yes 6. Conditioned floor area (W) 2035 ft2 _ 7. Glass typel and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 465.0 ft b. SHGC: (or Clear or Tint DEFAULT) 7b. (SHGC=0.6) 465.0 ft' 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 125.0(p) ft _ b. N/A _ c. N/A _ 9. Wall types a. Concrete, Int Insul, Exterior R=7.5, 1813.9 ft2 b. Frame, Wood, Adjacent R=11.0, 61.0 ft2 _ c. N/A _ d. N/A _ e. N/A _ 10. Ceiling types (white roof) _ a. Under Attic R=30.0, 1106.0 ft2 b. N/A _ c. N/A _ 11. Ducts(white roof) _ a. Sup: Unc. Ret: Con. AH: Attic Sup. R=6.0, 250.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (11R-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.23 Total as -built points: 26768 PASS .4 Total base points: 26920 I hereby certify that the plans and spe fi do d by this calculation are in compliance with on rgy Code. ( PREPARED BY: 4�". /2 L G IC t r DATE: Z ZA1 0 7 I hereby certify that this bui i g, as designed, is in compliance with the Florida Energy C OWNERIAGENT: DATE: ^ 7, Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Cap: 42.0 kBtu/hr _ SEER: 15.00 Cap: 42.0 kBtu/hr HSPF: 8.50 Cap: 40.0 gallons EF: 0.97 MZ-C, PT, CF, MZ- 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass out ut on p es EnergyGauge® (Version: FLRCPBt44��' / R ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 85.9 The higher the score, the more efficient the home. , , Ft. Pierce, FL, 1. New construction or existing New 2. Single family or multi -family Single family _ 3. Number of units, if multi -family 1 4. Number of Bedrooms 4 _ 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) 2035 ft2 7. Glass typel and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 465.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 7b. (SHGC=0.6) 465.0 ft2 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 125.0(p) ft _ b. N/A _ c. N/A _ 9. Wall types a. Concrete, Int Insul, Exterior R=7.5, 1813.9 ft- b. Frame, Wood, Adjacent R=11.0, 61.0 ft2 _ c. N/A d. N/A _ e. N/A _ 10. Ceiling types (white roof) a. Under Attic R=30.0, 1106.0 ft2 _ b. N/A _ c. N/A _ 11. Ducts(white roof) a. Sup: Unc. Ret: Con. AH: Attic Sup. R=6.0, 250.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, BF -Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final igspection. erwise, a new EPL Display Card will be completed based on installed Code fompliant fe es. Builder Sienature: // �i -��liy,.�r Date: t Address of New Home: City/FL Zip: Cap: 42.0 kBtu/hr SEER: 15.00 Cap: 42.0 kBhVhr _ HSPF: 8.50 Cap: 40.0 gallons _ EF: 0.97 _ MZ-C, PT, CF, MZ- *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStar'mdesignation), your home may qualij� for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCPB v IL5100: CO Py • ` 4 t � _ r Ft. Pierce, FL Summary Energy Code Results Residential Whole Building Performance Method A Project Title: Civiletto Residence Code Only Professional Version Climate: Central 12/19/2007 Building Loads Base As -Built Summer: 40179 points Summer: 44668 points Winter: 7261 points Winter: 11891 points Hot Water: 9053 points Hot Water: 9053 points Total: 56492 points I Total: 65612 points Energy Use Base As -Built Cooling: 13058 points Cooling: 11498 points Heating: 4022 points Heating: 5937 points Hot Water: 9840 points Hot Water: 9333 points Total: 26920 points Total: 26768 points —i PASS e-Ratio: 0.99 EnergyGaugeST,-OT� IiL%%ieE FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details _ V ADDRESS: , Ft. Pierce, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Omt Len Hgt Area X SPM X SOF = Points .18 2035.0 24.35 8919.0 1.Single, SHGC=0.6 N 1.0 5.0 15.0 22.38 0.96 322.0 2.Single, SHGC=0.6 W 1.0 1.3 7.5 44.35 0.61 202.0 3.Single, SHGC=0.6 E 0.0 0.0 22.5 49.38 1.00 1111.0 4.Single, SHGC=0.6 E 1.0 3.0 9.0 49.38 0.85 379.0 5.Single, SHGC=0.6 W 1.0 4.0 24.0 44.35 0.92 974.0 6.8ingle, SHGC=0.6 W 1.0 5.0 45.0 44.35 0.95 1895.0 7.Single, SHGC=0.6 S 8.0 5.0 30.0 36.80 0.51 565.0 8.Single, SHGC=0.6 E 1.0 6.0 15.0 49.38 0.95 703.0 9.8ingle, SHGC=0.6 E 1.0 5.0 22.5 49.38 0.95 1055.0 10.Single, SHGC=0.6 S 10.0 5.0 10.0 36.80 0.50 182.0 11.5ingle, SHGC=0.6 W 10.0 5.0 15.0 44.35 0.43 283.0 12.Single, SHGC=0.6 E 10.0 5.0 15.0 49.38 0.40 296.0 13.Single, SHGC=0.6 N 1.0 5.0 22.5 22.38 0.96 484.0 14.8ingle, SHGC-0.6 NE 1.0 7.0 35.0 35.89 0.98 1236.0 15.Single, SHGC=0.6 E 1.0 2.0 10.0 49.38 0.74 363.0 16.Single, SHGC=0.6 E 1.0 2.0 4.0 49.38 0.74 145.0 17.Single, SHGC=0.6 W 1.0 4.0 20.0 44.35 0.92 811.0 18.Single, SHGC=0.6 N 1.0 5.0 22.5 22.38 0.96 484.0 19.Single, SHGC=0.6 E 1.0 4.5 18.0 49.38 0.94 831.0 20.Single, SHGC=0.6 E 1.0 5.0 22.5 49.38 0.95 1055.0 21.Single, SHGC=0.6 S 1.0 7.0 35.0 36.80 0.97 1246.0 22.Single, SHGC=0.6 W 1.0 5.0 45.0 44.35 0.95 1895.0 As -Built Total: 466.0 16617.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 61.0 0.70 42.7 1. Concrete, Int Insul, Exterior 7.5 1813.9 0.75 1360.4 Exterior 1813.9 1.90 3446.4 2. Frame, Wood, Adjacent 11.0 61.0 0.70 42.7 Base Total: 1874.9 3489.1 As -Built Total: 1874.9 1403.1 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 1.Extedor Wood 21.0 7.20 151.2 Exterior 56.0 4.80 268.8 2.Exterior Insulated. 35.0 4.80 168.0 Base Total: 56.0 268.8 As -Built Total: 56.0 319.2 EnergyGauge® DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLR FORM 60OA-2004R EnergyGaugeO 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , Ft. Pierce, FL, PERMIT #: BASE AS -BUILT CEILING TYPES Area X BSPM = Points Type (white Root) R-Value Area X SPM X SCM = Points Under Attic 1106.0 2.13 2355.8 1. Under Attic 30.0 1106.0 2.13 X 0.55 1295.7 Base Total: 1106.0 2355.8 As -Built Total: 1106.0 1295.7 FLOOR TYPES Area X BSPM = Points Type R Value Area X SPM = Points Slab 125.0(p) -31.8-3975.0 1. Slab -On -Grade Edge Insulation 0.0 125.0(p -31.90 -3987.5 Raised 0.0 0.00 0.0 Base Total: -3975.0 As -Built Total: 125.0 -3987.5 INFILTRATION Area X BSPM = Points Area X SPM = Points 2035.0 14.31 29120.9 2035.0 14.31 29120.9 Summer Base Points: 40178.5 Summer As -Built Points: 44668.4 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 42000btuh ,SEER/EFF(15.0) DuctsAtt(S),Con(R),Att(AH),R6.0(INS) 44668 1.00 (1.04 x 1.150 x 1.10) 0.227 0.857 11498.1 40178.5 0.3260 13068.0 44668.4 1.00 1.321 0.227 0.857 11498.1 "Em EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FL v, 5L t': FORM 60OA-2004R EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details r ADDRESS: , Ft. Pierce, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 2035.0 9.11 3337.0 1.Single, SHGC=0.8 N 1.0 5.0 15.0 15.49 1.00 231.0 2.Single, SHGC=0.6 W 1.0 1.3 7.5 14.00 1.07 112.0 3.Single, SHGC=0.6 E 0.0 0.0 22.5 13.28 1.00 298.0 4.Single, SHGC=0.6 E 1.0 3.0 9.0 13.28 1.03 123.0 5.Single, SHGC=0.6 W 1.0 4.0 24.0 14.00 1.01 339.0 6.Single, SHGC=0.6 W 1.0 5.0 45.0 14.00 1.01 633.0 7.Single, SHGC=0.6 S 8.0 5.0 30.0 11.24 2.14 723.0 8.Single, SHGC=0.6 E 1.0 5.0 15.0 13.28 1.01 201.0 Mingle, SHGC=0.6 E 1.0 5.0 22.5 13.28 1.01 302.0 10.Single, SHGC=0.6 S 10.0 5.0 10.0 11.24 2.22 249.0 11.5ingle, SHGC=0.6 W 10.0 5.0 15.0 14.00 1.11 232.0 12.8ingle, SHGC=0.6 E 10.0 5.0 15.0 13.28 1.28 254.0 13.Single, SHGC=0.6 N 1.0 5.0 22.5 15.49 1.00 347.0 14.Single, SHGC=0.6 NE 1.0 7.0 35.0 15.20 1.00 532.0 15.Single, SHGC=0.6 E 1.0 2.0 10.0 13.28 1.06 140.0 16.Single, SHGC=0.6 E 1.0 2.0 4.0 13.28 1.06 56.0 17.Single, SHGC=0.6 W 1.0 4.0 20.0 14.00 1.01 282.0 18.Single, SHGC=0.6 N 1.0 5.0 22.5 15.49 1.00 347.0 19.Single, SHGC=0.6 E 1.0 4.5 18.0 13.28 1.01 242.0 20.Single, SHGC=0.6 E 1.0 5.0 22.5 13.28 1.01 302.0 21.Single, SHGC=0.6 S 1.0 7.0 35.0 11.24 1.00 393.0 22.Single, SHGC=0.6 W 1.0 5.0 45.0 14.00 1.01 633.0 As -Built Total: 465.0 6971.0 WALL TYPES Area X BWPM = Points Type R Value Area X WPM = Points Adjacent 61.0 1.80 109.8 1. Concrete, Int Insul, Exterior 7.5 1813.9 2.20 3990.6 Exterior 1813.9 2.00 3627.8 2. Frame, Wood, Adjacent 11.0 61.0 1.80 109.8 Base Total: 1874.9 3737.6 As -Built Total: 1874.9 4100.4 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Wood 21.0 7.60 159.6 Exterior 56.0 5.10 285.6 2.Extedor Insulated 35.0 5.10 178.5 Base Total: 56.0 285.6 As -Built Total: 56.0 338.1 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R F B 4 .20 v4 FORM 60OA-2004R ` , „ a EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , Ft. Pierce, FL, PERMIT #: BASE AS -BUILT CEILING TYPES Area X BWPM = Points Type (White Roof) R-Value Area X WPM X WCM = Points Under Attic 1106.0 0.64 707.8 1. Under Attic 30.0 1106.0 0.64 X 1.04 739.0 Base Total: 1106.0 707.8 As -Built Total: 1106.0 739.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 125.0(p) -1.9 -237.5 1. Slab -On -Grade Edge Insulation 0.0 125.0(p 2.50 312.5 Raised 0.0 0.00 0.0 Base Total: -237.5 As -Built Total: 125.0 312.5 INFILTRATION Area X BWPM = Points Area X WPM = Points 2035.0 -0.28 -569.8 2035.0 -0.28 -569.8 Winter Base Points: 7260.7 Winter As -Built Points: 11891.2 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 42000 btuh ,EFF(8.5) Ducts:Att(S),Con(R),Att(AH),R6.0 11891.2 1.000 (1.070 x 1.160 x 1.11) 0.402 0.902 5936.8 7260.7 0.5640 4022.6 11891.2 1.00 1.378 0.402 0.902 6936.8 r EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FL PB J.t F FORM 60OA-2004R EnergyGauge® 4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , Ft. Pierce, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 4 2450.09 9840.0 40.0 0.97 4 1.00 2333.20 1.00 9332.8 As -Built Total: 9332.8 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 13068 4022 9840 26920 1 11498 5937 9333 26768 PASS am EnergyGaugeTM' DCA Form 600A-2004R EnergyGauge6/FIaRES'2004R FL PB 2 r COPY FORM. 60OA-2004R EnergyGauge® 4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , Ft. Pierce, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. F1 ROM EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLR FVtLL a 1 �3 Lot 2f172 Nettles Island HVAC Load Calculations for Civiletto Residence Lot 2173 Fort Pierce, Florida E El CE- j 1 -S� 1 j -"V/AC HVAC LADs Prepared By: Residential Energy CaVs Wednesday, December 19, 2007 ►, , Rhvael- - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie, FL 34983 Page 2 I -Project Report I General-Project,information % -Project Title: Lot 2172 Nettles Island Designed By: Back Draft Services Project Date: Wednesday, December 05, 2007 Client Name: Civiletto Residence Client Address: Lot 2173 Client City: Fort Pierce, Florida Company Name: Residential Energy Caic's Design Data -` - Reference City: Fort Pierce, Florida Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: 42 0 30 72 3 Summer: 90 78 50 75 61 I -Check Figures` z'' Total Building Supply CFM: 1,405 CFM Per Square ft.: 0.690 Square ft. of Room Area: 2,035 Square ft. Per Ton: 566 Volume (ft3) of Cond. Space: 18,975 Air Turnover Rate (per hour): 4.4 Total Heating Required With Outside Air: 42,017 Btuh 42.017 MBH Total Sensible Gain: 32,362 Btuh 82 % Total Latent Gain: 7,260 Btuh 18 % Total Cooling Required With Outside Air: 39,622 Btuh 3.30 Tons (Based On Sensible + Latent) 3.60 Tons (Based On 75% Sensible Capacity) Nqtes.,- Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Rhvac - Residential & Light Commercial HV_AC Loads Elite Software Development, Inc. Ken Humphrey F Lot 2172 Nettles Island Port Saint Lucie FL 34983 Pa e 3 Miscellaneous Report :System ,1. Carrier Or.Eduivalent:.: :4 .-, . ; _, Outdoor... Outdoor 5, ::.;.., :-Indoor, .Indoor ;Grains,. Input.Data, _ ;, � Dry Bulb �� .Wet_B6b� ReLHum. Dry,Bulb Difference Winter: 42 0 30 72 3.44 Summer: 90 78 50 75 61.09 [-Duct-Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside--Air-Data _ _ �. ✓ `x;, a r.. —. .t Winter Summer Infiltration: 0.130 AC/hr 0.070 AC/hr Above Grade Volume: X 18,975 Cu.ft. X 18,975 Cu.ft. 2,467 Cu.ft./hr 1,328 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 41 CFM 22 CFM Total Building Ventilation: 90 CFM 90 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) Duct,,Load:Factor--Scenanos,for4System:1- :,.,.,=- ,Attic Q t. Duct From 0,1_Type `Description;; ,n Locatto_ri t 4 ..- : ...,.Surface.' Ceifin Leaka e_ Insulation Area. , MDD tg �. :f z.� .... 9 1 Supply Main Attic 16B 0.12 6 550 No 1 Return Main Attic 16B 0.24 6 102 No Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie, FL 34983 ° Pa e 4 Load Preview I Has Net I2e'c ft Z i _ $en 1 Laf " y Net Sen Sy9 �L:�As Scope f AED Tong Ton' /Toff Area j: Gain Gain �i. ` Gain "Loss { Size CFM 1- CFMM Building 3.30; 3.601 566 2,035'1 32,3621 7,260� 39,622! 42,017; 5081 1,405', 1,405, -System 1 No 3.30, 3.60 566, 2,035 32,362 7,260• 39,622 42,017• 508 1,405 12x20 Ventilation - - 1,484. 3,735 - 5,219! 2,96T - - - J- Duct Latent 2,106 2,106, Zone 1 929; 20,393 976 21,369 23,316 303' 928 12x14 1-Bedroom 4 - -- - 173 - - 2,189; 313. 2,502 - -- ----- 4,107 53;_ 100 1-6 2-Golf Cart Room 100, 1_,962' 79' 2_ ,_041; 3,302 - 43 ® 89 1-6 - - - 0 - - 9' 1-', - - - 0.- -- 0-0 4-Bath 2 - - 63 ., 90 O' 104' 24, 4 120 754 _ 5 1-4 5-Stairway - 1 48' - 6_41; - - 38' 679. -` 1,260 16.,_ 291 1-4 6-IGVg chen • ' 134 1-7 252' 9,051' 115, 9,166' 7,836. �_ 102 41212 ', 4-6 - - - -- - 8-Nook - - -, 60 3,511, 72 3,583' 4,370 ---- 5.7 Zone 2 1,106' 18,416 443, 18,859' 15,733. 205 ® 838 10x16 9-Bedroom 3 229 3,375' 139 3,514 4,833: 63_ 154, 1-7 10-Bath 3 59, 311' 17; 328 427 6',_ 14 1-4 11-Hall2 98, 153, 0 153 124 2!M 7 1-4 - - 12-Stairway -- - 64 2,708' 51 2,759 1,356 _ -18 - - 123� - 1-7 13-Bedroom 2 _ - 144 1,232, 34 _ 1,266 1,559 20 56 1-4 14-Master Bath 117, 1,005 28 1,033 1,257 16' 46 1-4 15-Laundry 31 173, ^ 17 190 322' _ 4. & 1-4 16-Walk In Closet 112. 425 57 482• 794 10; 19 1-4 17-Master Bedroom 252 9,033; 100. 9,133 5,060; 66I® 411: 4-6 Sum of room airflows may be greater than system airflow because system has multiale zones. e S-•^ r ti �1r tF a to Rhvae - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie, FL 34983 Page 5 Total Building Summary Loads Component,. '" Area - Sen. y -.Lat. _ Sen.; r ;Total.. .Description �. f _ ,Quan Loss Gain Gain.y, .,-Gain 1A-hb-o: Glazing -Single pane, operable window, heat- 15 486 0 294 294 absorbing, metal frame with break, outdoor insect screen with 50% coverage, light color closed blinds with 50% coverage, u-value 1.08 1A-hb-o: Glazing -Single pane, operable window, heat- 7.8 250 0 246 246 absorbing, metal frame with break, outdoor insect screen with 50% coverage, light color closed blinds with 50% coverage, u-value 1.07 1A-hb-o: Glazing -Single pane, operable window, heat- 40.5 1,300 0 2,818 2,818 absorbing, metal frame with break, u-value 1.07 7A-1: Glazing -Glass or plastic block, smooth or wide ribs 9 162 0 522 522 or flutes, no screen, no coating, u-value 0.6 IA-hb-o: Glazing -Single pane, operable window, heat- 325 10,434 0 11,934 11,934 absorbing, metal frame with break, outdoor insect screen with 50% coverage, light color blinds at 450 with 50% coverage, u-value 1.07 1A-hm-o: Glazing -Single pane, operable window, heat- 35 1,334 0 1,548 1,548 absorbing, metal frame no break, outdoor insect screen with 50% coverage, light color blinds at 450 with 50% coverage, u-value 1.27 1A-hm-o: Glazing -Single pane, operable window, heat- 10 381 0 477 477 absorbing, metal frame no break, light color blinds at 460 with 60% coverage, u-value 1.27 1A-hm-o: Glazing -Single pane, operable window, heat- 35 666 0 666 666 absorbing, metal frame no break, outdoor insect screen with 50% coverage, light color blinds at 450 with 50% coverage, in partition wall, u-value 1.27 11 N: Door -Metal - Polystyrene Core 35 368 0 318 318 11 D: Door -Wood - Solid Core 21 246 0 213 213 13A-7.5ocs: Wall -Block, board insulation only, R-7.5 1655.2 4,718 0 2,093 2,093 board insulation, open core, siding finish 13A7.5ocs: Wall- 158.7 681 0 347 347 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity, 61 88 0 88 88 no board insulation, siding finish, wood studs 16C-30: Roof/Ceiling-Under attic or knee wall, Vented 1105.8 1,061 0 1,415 1,415 Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 149 6,071 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 28,246 0 22,979 22,979 People: 1 200 230 430 Equipment: 300 300 600 Lighting: 0 0 0 Ductwork: 9,447 2,106 6,866 8,971 Infiltration: Winter CFM: 41, Summer CFM: 22 1,356 919 365 1,284 Ventilation: Winter CFM: 90, Summer CFM: 90 2,967 3,735 1,484 5,219 AED Excursion: 0 0 139 139 Total Building Load Totals: 42,017 7,260 32,362 39,622 Check Figures' Total Building Supply CFM: 1,405 CFM Per Square ft.: 0.690 Square ft. of Room Area: 2,035 Square ft. Per Ton: 566 Volume (ft) of Cond. Space: 18,975 Air Turnover Rate (per hour): 4.4 Rhva6 - Residential & Light Commercial HVAC Loads Ken Humphrey iNk Elite Software Development, Inc. Lot 2172 Nettles Island Port Saint Lucia, FL 34983 Page 6 1Total Building Summary Loads (contd) J,Buildifig,Loads - 7. .Total Heating Required With Outside Air: 42,017 Btuh 42.017 MBH Total Sensible Gain: 32,362 Btuh 82 % Total Latent Gain: 7,260 Btuh 18 % Total Cooling Required With Outside Air: 39,622 Btuh 3.30 Tons (Based On Sensible + Latent) 3.60 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. E3 I U n 0V 101- 1A -1P A& RIA. 11,11 a. h Pi, 0 lkhva'c-Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Netfles Island Port Saint Lucia, FL 34983 W Page 7 System I Carrier Or Equivalent Summary Loads Component ;Area,, Sen: Lat. -,Sen,Total Description-.: Gain .,,-,-Gain.. Gain 1A-hb-o: Glazing -Single pane, operable window, heat- 15 486 0 294 294 absorbing, metal frame with break, outdoor insect screen with 50% coverage, light color closed blinds with 50% coverage, u-value 1.08 IA-hb-o: Glazing -Single pane, operable window, heat- 7.8 250 0 246 246 absorbing, metal frame with break, outdoor insect screen with 50% coverage, light color closed blinds with 50% coverage, u-value 1.07 1A-hb-o: Glazing -Single pane, operable window, heat- 40.5 1,300 0 2,818 2,818 absorbing, metal frame with break, u-value 1.07 7A-1 , Glazing -Glass or plastic block, smooth or wide ribs 9 162 0 522 522 or flutes, no screen, no coating, u-value 0.6 1A-hb-o: Glazing -Single pane, operable window, heat- 325 10,434 0 11,934 11,934 absorbing, metal frame with break, outdoor insect screen with 50% coverage, light color blinds at 450 with 50% coverage, u-value 1.07 IA-hm-o: Glazing -Single pane, operable window, heat- 35 1,334 0 1,548 1,548 absorbing, metal frame no break, outdoor insect screen with 50% coverage, light color blinds at 450 with 50% coverage, u-value 1.27 1A-hm-o: Glazing -Single pane, operable window, heat- 10 381 0 477 477 absorbing, metal frame no break, light color blinds at 450 with 50% coverage, u-value 1.27 1A-hm-o: Glazing -Single pane, operable window, heat- 35 666 0 666 666 absorbing, metal frame no break, outdoor insect screen with 50% coverage, light color blinds at 450 with 50% coverage, in partition wall, u-value 1.27 11 N: Door -Metal - Polystyrene Core 35 368 0 318 318 11 D: Door -Wood - Solid Core 21 246 0 213 213 13A-7.5ocs: Wall -Block, board insulation only, R-7.5 1655.2 4,718 0 2,093 2,093 board insulation, open core, siding finish 13A7.5ocs: Wall- 158.7 681 0 347 347 1213-0sw: Part -Frame, R-1 1 insulation in 2 x 4 stud cavity, 61 88 0 88 88 no board insulation, siding finish, wood studs 16C-30: Roof/Ceiling-Under attic or knee wall, Vented 1105.8 1,061 0 1,415 1,415 Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 149 6,071 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 28,246 0 22,979 22,979 People: 1 200 230 430 Equipment: 300 300 600 Lighting: 0 0 0 Ductwork: 9,447 2,106 6,866 8,971 Infiltration: Winter CFM: 41, Summer CFM: 22 1,356 919 365 1,284 Ventilation: Winter CFM: 90, Summer CFM: 90 2,967 3,735 1,484 5,219 AED Excursion: 0 0 139 139 System 1 Carrier Or Equivalent Load Totals: 42,017 7,260 32,362 39,622 I'Phock'Fig'4r6s,- Supply CFM: 1,405 CFM Per Square ft.: 0.690 Square ft. of Room Area: 2,035 Square ft. Per Ton: 566 Volume (fF) of Cond. Space: 18,975 Air Turnover Rate (per hour): 4.4 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie FL 34983 Page 8 System 1 Carrier Or Equivalent Summary Loads (cont'd) System Loads,. -Total Heating Required With Outside Air: 42,017 Btuh 42.017 MBH Total Sensible Gain: 32,362 Btuh 82 % Total Latent Gain: 7,260 Btuh 18 % Total Cooling Required With Outside Air: 39,622 Btuh 3.30 Tons (Based On Sensible + Latent) 3.60 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. F I L 'L"� 1 �" Copyr Rhvac - Residential & Light Commercial HVAC Loads AL'N", Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie, FL 34983 MW Page 9 System 1, Zone I Summary Loads (Peak Load Procedure for Rooms) Component., -Are. Sen ---- Total, Total,, .,Description Quan LossGain', .,-.,,..,Gain. Gain 1A-hb-o: Glazing -Single pane, operable window, heat- 15 486 0 294 294 absorbing, metal frame with break, outdoor insect screen with 50% coverage, light color closed blinds with 50% coverage, u-value 1.08 1A-hb-o: Glazing -Single pane, operable window, heat- 7.8 250 0 246 246 absorbing, metal frame with break, outdoor insect screen with 50% coverage, light color closed blinds with 50% coverage, u-value 1.07 1A-hb-o: Glazing -Single pane, operable window, heat- 22.5 722 0 1,659 1,659 absorbing, metal frame with break, u-value 1.07 7A-1: Glazing -Glass or plastic block, smooth or wide ribs 9 162 0 522 522 or flutes, no screen, no coating, u-value 0.6 1A-hb-o: Glazing -Single pane, operable window, heat- 190.5 6,118 0 6,708 6,708 absorbing, metal frame with break, outdoor insect screen with 50% coverage, light color blinds at 45* with 50% coverage, u-value 1.07 11 N: Door -Metal - Polystyrene Core 35 368 0 318 318 11 D: Door -Wood - Solid Core 21 246 0 213 213 13A-7.5ocs: Wall -Block,. board insulation only, R-7.5 894.8 2,551 0 1,131 1,131 board insulation, open core, siding finish 22A-ph: Floor -Slab on grade, No edge insulation, no 149 6,071 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 16,974 0 15,994 15,994 People: 1 200 230 430 Equipment: 300 300 600 Lighting: 0 0 0 Ductwork: 5,641 0 3,608 3,608 Infiltration: Winter CFM: 21, Summer CFM: 11 701 476 188 664 System 1, Zone 1 Load Totals: 23,316 976 20,393 21,369 1,Check,jFigures. Supply CFM: 928 CFM Per Square ft.: 0.999 Square ft. of Room Area: 929 Square ft. Per Ton: 502 Volume (ft') of Cond. Space: 7,586 Air Turnover Rate (per hour): 7.3 Total Heating Required: 23,316 Btuh 23.316 MBH Total Sensible Gain: 20,393 Btuh 95 % Total Latent Gain: 976 Btuh 5 % Total Cooling Required: 21,369 Btuh 1.78 Tons (Based On Sensible + Latent) 1.85 Tons (Based On 75% Sensible Capacity) [Nbtee' Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. r M I I r, Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie FL 34983 Page 10 System 1, Zone 2 Summary Loads ((Peak Load Procedure for Rooms) Component. .Area, .. Sen Lat . _' Sen.Total -Description Quan-, Loss . ,Gain ;Gain Gain. 1A-hb-o: Glazing -Single pane, operable window, heat- 134.5 4,316 0 5,226 59226 absorbing, metal frame with break, outdoor insect screen with 50% coverage, light color blinds at 45° with 50% coverage, u-value 1.07 1A-hm-o: Glazing -Single pane, operable window, heat- 35 1,334 0 1,548 1,548 absorbing, metal frame no break, outdoor insect screen with 50% coverage, light color blinds at 450 with 50% coverage, u-value 1.27 1A-hm-o: Glazing -Single pane, operable window, heat- 10 381 0 477 477 absorbing, metal frame no break, light color blinds at 450 with 50% coverage, u-value 1.27 1A-hb-o: Glazing -Single pane, operable window, heat- 18 578 0 1,159 1,159 absorbing, metal frame with break, u-value 1.07 1A-hm-o: Glazing -Single pane, operable window, heat- 35 666 0 666 666 absorbing, metal frame no break, outdoor insect screen with 50% coverage, light color blinds at 45° with 50% coverage, in partition wall, u-value 1.27 13A-7.5ocs: Wall -Block, board insulation only, R-7.5 760.4 2,167 0 962 962 board insulation, open core, siding finish 13A7.5ocs: Wall- 168.7 681 0 347 347 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity, 61 88 0 88 88 no board insulation, siding finish, wood studs 16C-30: Roof/Ceiling-Under attic or knee wall, Vented 1105.8 1,061 0 1,415 1,415 Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation Subtotals for structure: 11,272 0 14,915 14,915 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 3,806 0 3,258 3,258 Infiltration: Winter CFM: 20, Summer CFM: 11 655 443 177 620 System 1, Zone 2 Load Totals: 15,733 443 18,416 18,859 Check Figures • , s. Supply CFM: 838 CFM Per Square ft.: 0.758 Square ft. of Room Area: 1,106 Square ft. Per Ton: 690 Volume (ft') of Cond. Space: 11,389 Air Turnover Rate (per hour): 4.4 Total Heating Required: 15,733 Btuh 15.733 MBH Total Sensible Gain: 18,416 Btuh 98 % Total Latent Gain: 443 Btuh 2 % Total Cooling Required: 18,859 Btuh 1.57 Tons (Based On Sensible + Latent) 1.60 Tons (Based On 75% Sensible Capacity) Notes h Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. gm—,�� fE4%ONVI Rhvac - Residential & Light Commercial H VAC Loads Elite Software Development, Inc. Ken Humphrey 14110-N Lot 2172 Nettles Island Port Saint Lucie, FL 34983 AV Page 11 I'Detailed Room Loads - Room 1 - Bedroom 4 (Peak Fenestration Gain Procedure) :General.-,. -Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 15.0 ft. System Number: I Room Width: 11.5 ft. Zone Number: 1 Area: 173.0 sq.ft. Supply Air: 100 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.3 AC/hr Volume: 1,380.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 9 CFM Runout Air: 0 CFM Percent of Supply.: 10 % Runout Duct Size: 6 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 507 ft./min. Percent of Supply: 5 % Runout Air Velocity: 507 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.165 in.wg./l 00 ft. Actual Summer Infil.: 3 CFM Item-, Area .-U-_ "tg"' 'Sen,1�'�­:HTM�­ _,CIg,,___. Lat.Sen Description ­.�;�_--sQuantiiY-1 ­,t—Value - ..,Loss,,.,, HTM,,,__ .Gain_.-,: Gaiw N -Wall-I 3A-7.5ocs 15 X 8 105 0.095 2.9 299 1.3 0 133 W -Wall-1 3A-7.5ocs 20.5 X 8 156.2 0.095 2.9 445 1.3 0 197 N -GIs-IA-hb-o shgc-0.52 10%S 15 1.080 32.4 486 26.9 0 403 W -GIs-lA-hb-o shgc-0.6 7%S 7.8 1.070 32.1 250 100.8 0 786 Floor-22A-ph 36 ft..Per. 36 1.358 40.7 1,467 0.0 0 0 Subtotals for Structure: 2,947 0 1,519 Infil.: Win.: 5.0, Sum.: 2.7 284 0.585 166 0.158 113 45 Ductwork: 994 387 AED Excursion: 8 People: 200 la per, 230 senjper: 1 200 230 Room Totals: 4,107 313 2,189 n PV 1'444�41MIIFO� �=Ml Rhvac - Residential & Light Commercial HVAC Loads Ken Humphrey 9 "n= Elite Software Development, Inc. Lot 2172 Nettles Island Port Saint Lucie, FL 34983 Page 12 -Detailed Room Loads - Room 2 - Golf Cart Room (Peak Fenestration Gain Procedure) -General- .. r .._ -.,.. ... ., .. • • . .. _ • .. . . r . .,, .., ._, . _ ,-.. Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 10.0 ft. System Number: 1 Room Width: 10.0 ft. Zone Number: 1 Area: 100.0 sq.ft. Supply Air: 89 CFM Ceiling Height: 9.6 ft. Supply Air Changes: 5.6 AC/hr Volume: 960.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 8 CFM Runout Air: 0 CFM Percent of Supply.: 9 % Runout Duct Size: 6 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 455 ft./min. Percent of Supply: 5 % Runout Air Velocity: 455 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.133 in.wg./100 ft. Actual Summer Infil.: 2 CFM Item Area =lJ- ' ' Htg,. Sen Clg Lat.Sang - _ , Description;, , . ' :. ty .>-, Quanti Value• , .. HTM : L'oss : HTM _: Gain Gain N -Wall-13A-7.5ocs 10 X 9 90 0.095 2.9 257 1.3 0 114 E -Wall-13A-7.5ocs 12 X 9 50.5 0.095 2.9 144 1.3 0 64 E-Door-11 N 5 X 7 35 0.350 10.5 368 9.1 0 318 E -GIs-1A-hb-o shgc-0.6 0%S 22.5 1.070 32.1 722 48.0 0 1,081 Floor-22A-ph 22 ft..Per. 22 1.358 40.7 896 0.0 0 0 Subtotals for Structure: 2,387 0 1,577 Infil.: Win.: 3.5, Sum.: 1.9 198 0.586 116 0.157 79 31 Ductwork: 799 347 AED Excursion: 7 Room Totals: 3,302 79 1,962 P 111: r) PV Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie FL 34983 mull Fa a 13 Detailed Room Loads - Room 3 - Hall (Peak Fenestration Gain Procedure) Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 15.7 ft. System Number: 1 Room Width: 4.0 ft. Zone Number: 1 Area: 63.0 sq.ft. Supply Air: 0 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 0.0 AC/hr Volume: 502.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 0 Actual Winter Vent.: 0 CFM Runout Air: 0 CFM Percent of Supply.: 0 % Runout Duct Size: 0 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 0 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item. -. _ „r ••< .: Area t .: =U- 171t : .. , . ,Sen ,; Clg La, Sen � .Description , z Quantity.. ,Value _ HTM-;f, Loss_ . HTM � Gain � rz x Gairr Floor-22A-ph 1 ft..Per. 1 1.358 40.7 41 0.0 0 0 Subtotals for Structure: 41 0 0 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 13 0 Room Totals: 54 0 0 ��n PY Rhvac - Residential 0, Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie, FL 34983 AV Page 14 Detailed Room Loads - Room 4 - Bath 2 (Peak Fenestration Gain Procedure) _ Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 7.5 ft. Zone Number: 1 Area: 90.0 sq.ft. Supply Air: 5 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 0.4 AC/hr Volume: 720.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 0 CFM Percent of Supply.: 34 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 54 ft./min. Percent of Supply: 5 % Runout Air Velocity: 54 ft./min. Actual Winter Infil.: 1 CFM Actual Loss: 0.004 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item. _ .. , ; Area,_ -U- _ .... _Htg ; Sen Clg Lat ; e Sen. -Description ._ . _Quantity • ,Value .HTM ,Loss. ,; «. HTM ;,Gain; Gain W -Wall-13A-7.5ocs 7.5 X 8 60 0.095 2.9 171 1.3 0 76 Floor-22A-ph 8 ft..Per. 8 1.358 40.7 326 0.0 0 0 Subtotals for Structure: 497 0 76 Infil.: Win.: 1.1, Sum.: 0.6 60 0.583 35 0.150 24 9 Ductwork: 170 18 AED Excursion: 0 Room Totals: 702 24 104 P,. 5 Ksm i kF11 ­�&, W Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey dal& Lot 2172 Nettles Island Port Saint Lucie, FL 34083 mull I Pa-ge 15 I'Detailed Room Loads - Room 5 - Stairway (Peak Fenestration Gain Procedure) General Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & cIg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 4.0 ft. Zone Number: I Area: 48.0 sq.ft. Supply Air: 29 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.6 AC/hr Volume: 384.0 cu.ft. Required Vent.: 0 CFM Number of Registers: I Actual Winter Vent.: 3 CFM Runout Air: 0 CFM Percent of Supply.: 10 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 334 ft./min. Percent of Supply: 5 % Runout Air Velocity: 334 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.128 in.wg./l 00 ft. Actual Summer Infil.: 1 CFM Item Area , - f - , - ,,. 4 --U- - -,- - i, -, , Sen - CIg-- Lat,,, ,Description "Quantity, Value. - Los S HTM, -�,,Gain E -Wall-1 3A-7.5ocs 12 X 8 87 0.095 2.9 248 1.3 0 110 E -GIs-7A-1 shgc-0.65 0%S (2) 9 0.600 18.0 162 44.4 0 400 Floor-22A-ph 12 ft..Per. 12 1.358 40.7 489 0.0 0 0 Subtotals for Structure: 899 0 510 Infil.: Win.: 1.1, -Sum.: 0.9 96 '0.583 56 0.156 38 15 Ductwork: 305 113 AED Excursion: 2 Room Totals: 1,260 38 641 0 PY DOW & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey '' Lot 2172 Nettles Island Port Saint Lucie, FL 34983 Page 16 Detailed Room Loads - Room 6 - Kitchen (Peak Fenestration Gain Procedure) Genetal,­. Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 13.0 ft. System Number: I Room Width: 11.0 ft. Zone Number: I Area: 143.0 sq.ft. Supply Air: 134 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 7.0 AC/hr Volume: 1,144.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: 0 CFM Percent of Supply.: 3 % Runout Duct Size: 7 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 500 ft./min. Percent of Supply: 5 % Runout Air Velocity: 500 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.129 in.wg./l 00 ft. Actual Summer Infil.: 1 CFM Jtem .9 -..,Sen Qig,. Lat, ,Description- _',,:Quantity-, —iValue.- ,-,.HTM Loss- HTM,-.Gain,-,.-. - Gain. W -Wall-1 3A-7.5ocs 11 X 8 70 0.095 2.9 200 1.3 0 88 W -GIs-lA-hb-o shgc-0.6 2%S 18 1.070 32.1 578 111.3 0 2,004 Floor-22A-ph 11 ft.. Per. 11 1.358 40.7 448 0.0 0 0 Subtotals for Structure: 1,226 0 2,092 Infil.: Win.: 1.6, Sum.: 0.8 88 0.591 52 0.159 36 14 Ductwork: 408 519 AED Excursion: 11 Equipment: 300 300 Room Totals: 1,686 335 2,936 r) PV Rhvac -sid Reential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie, FL 34983 O Page 17 Detailed Room Loads - Room 7 - Living (Peak Fenestration Gain Procedure) General. 1. _Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 21.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 252.0 sq.ft. Supply Air: 412 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 12.3 AC/hr Volume: 2,016.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 4 Actual Winter Vent.: 18 CFM Runout Air: 0 CFM Percent of Supply.: 4 % Runout Duct Size: 6 in. Actual Summer Vent.: 21 CFM Runout Air Velocity: 524 ft./min. Percent of Supply: 5 % Runout Air Velocity: 524 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.176 in.wg./l00 ft. Actual Summer Infil.: 3 CFM .. o :Htg.. , , . Sena YCIg Lat Sen. Description .,---•:Quantity ° - Value s: ,HTM . • Loss-, ,.,.:: :HTM , : , • -.Gain Gain' W -Wall-13A-7.5ocs 12.6 X 8 55.8 0.095 2.9 159 1.3 0 71 S -Wall-13A-7.5ocs 11 X 8 58 0.095 2.9 165 1.3 0 73 E -Wall-13A-7.5ocs 12.6 X 8 42.3 0.095 2.9 121 1.3 0 53 E-Door-11 D 3 X 7 21 0.390 11.7 246 10.1 0 213 W -GIs-lA-hb-o shgc-0.6 2%S (2) 45 1.070 32.1 1,444 111.7 0 5,028 S -GIs-IA-hb-o shgc-0.6 0%S (2) 30 1.070 32.1 964 26.3 0 788 E -GIs-IA-hb-o shgc-0.6 0%S 15 1.070 32.1 482 30.5 0 458 E -GIs-lA-hb-o shgc-0.6 0%S 22.5 1.070 32.1 722 30.5 0 687 Floor-22A-ph 36 ft..Per. 36 1.358 40.7 1,467 0.0 0 0 Subtotals for Structure: 5,770 0 7,371 Infil.: Win.: 5.1, Sum.: 2.8 290 0.587 170 0.159 115 46 Ductwork: 1,896 1,601 AED Excursion: 32 Room Totals: 7,836 115 9,051 ���rl PV Rhvic -'Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Ida& Lot 2172 Nettles Island Port -Saint Lucie, FL 34983 MW Page 18 Detailed Room Loads - Room 8 - Nook (Peak Fenestration Gain Procedure) Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 10.0 ft. System Number. 1 Room Width: 6.0 ft. Zone Number: I Area: 60.0 sq.ft. Supply Air: 160 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 20.0 AC/hr Volume: 480.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 10 CFM Runout Air: 0 CFM Percent of Supply.: 6 % Runout Duct Size: 8 in. Actual Summer Vent.: 8 CFM Runout Air Velocity: 458 ft./min. Percent of Supply: 5 % Runout Air Velocity: 458 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.091 in.wg./I 00 ft. Actual Summer Infil.: 2 CFM Item .Htg Description,-, Quantityv1`,,,.,. nValue. TM& _ .Loss S -Wall-1 3A-7.5ocs 11 X 8 58 0.095 2.9 165 1.3 0 73 W -Wall-1 3A-7.5ocs 5.5 X 8 29 0.095 2.9 83 1.3 0 37 E -Wall-1 3A-7.5ocs 6 X 8 33 0.095 2.9 94 1.3 0 42 S -GIs-lA-hb-o shgc-0.6 O%S (2) 30 1.070 32.1 964 26.3 0 788 W -GIs-lA-hb-o shgc-0.6 20%S 15 1.070 32.1 482 96.7 0 1,451 E -GIs-1A-hb-o shgc-0.6 O%S 15 1.070 32.1 482 30.5 0 458 Floor-22A-ph 23 ft..Per. 23 1.358 40.7 937 0.0 0 0 Subtotals for Structure: 3,207 0 2,849 Infil.: Win.: 3.2, Sum.: 1.7 180 0.589 106 0.156 72 28 Ductwork: 1,057 621 AED Excursion: 13 Room Totals: 4,370 72 3,511 PV Rhveic -'Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island LPort Saint Lucia, FL 34983 Page 19 FDetailed Room Loads - Room 9 - Bedroom 3(Pewak Fenestration Gain Procedure) 1,General -'Room is in zone 2, which peaks at 5 pm Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 18.0 ft. System Number: 1 Room Width: 12.7 ft. Zone Number: 2 Area: 229.0 sq.ft. Supply Air: 154 CFM Ceiling Height: 12.0 ft. Supply Air Changes: 3.4 AC/hr Volume: 2,743.0 cu.ft. Required Vent.: 0 CFM Number of Registers: I Actual Winter Vent.: 11 CFM Runout Air. 0 CFM Percent of Supply.: 7 % Runout Duct Size: 7 in. Actual Summer Vent.: 8 CFM Runout Air Velocity: 575 ft./min. Percent of Supply: 5 % Runout Air Velocity: 575 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.171 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item -Descrilklon ..Area Quantity -Value,-, HTM: Loss,.,, Gain-- �,;',Gain E -Wall-1 3A-7.5ocs 12.7 X 10 117 0.096 2.9 333 1.3 0 148 NE-Wall-13A-7.5ocs 7.3 X 8 23.4 0.095 2.9 67 1.3 0 30 N -Wall-1 3A-7.5ocs 14.5 X 8 93.5 0.095 2.9 266 1.3 0 118 W -Wall-1 3A-7.5ocs 6 X 8 48 0.095 2.9 137 1.3 0 61 N -GIs-IA-hb-o shgc-0.6 10%S 22.5 1.070 32.1 722 29.9 0 673 NE-GIs-lA-hm-o shgc-0.6 O%S (2) 35 1.270 38.1 1,334 29.2 0 1,022 E -GIs-lA-hm-o shgc-0.6 O%S 10 1.270 38.1 381 36.6 0 366 UP-Ceii-16C-30 18 X 12.7 228.6 0.032 1.0 219 1.3 0 293 Subtotals for Structure: 3,459 0 2,711 Infil.: Win.: 6.2, Sum.: 3.3 349 0.587 205 0.157 139 55 Ductwork: - 1,169 597 AED Excursion: 12 Room Totals: 4,833 139 3,375 rw I I Erm ®rlic ArA nV Rhva'c .'Risidential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucia, FL 34983 Page 20 Detailed Room Loads - Room 10 - Bath 3160eak Fenestration Gain Procedure) 1,Gpneral, r. Room is in zone 2, which peaks at 5 pm Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 10.7 ft. System Number: I Room Width: 5.5 ft. Zone Number: 2 Area: 59.0 sq.ft. Supply Air: 14 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 1.4 AC/hr Volume: 589.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air. 0 CFM Percent of Supply.: 7 % Runout Duct Size: 4 in. Actual Summer Vent.: I CFM Runout Air Velocity: 162 ft./min. Percent of Supply: 5 % Runout Air Velocity: 162 ft./min. Actual Winter Infil.: 1 CFM Actual Loss: 0.031 in.wg./l 00 ft. Actual Summer Infil.: 0 CFM "!t Are Ht '§en," 9 -L-t Seri - Description Quantity�� -Value, HTM Loss----• 0HTMi, Gain, 2.,, Gain E -Wall-1 3A-7.5ocs 5.5 X 8 40 0.095 2.9 114 1.3 0 51 E -GIs-lA-hb-o shgc-0.6 O%S 4 1.070 32.1 128 30.5 0 122 UP-Ceil-16C-30 10.7 X 5.5 58.8 0.032 1.0 56 1.3 0 75 Subtotals for Structure: 298 0 248 Infil.: Win.: 0.8, Sum.: 0.4 44 0.591 26 0.159 17 7 Ductwork: 103 55 AED Excursion: I Room Totals: 427 17 311 fl PV Rhva7c - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucia, FL 34983 Page 21 Detailed Room Loads - Room 11 - Hag 2 (Peak Fenestration Gain Procedure) 1,General Room is in zone 2, which peaks at 5 pm Calculation Mode: Htg. & c1g. Occurrences: Room Length: 24.5 ft. System Number: Room Width: 4.0 ft. Zone Number: 2 Area: 98.0 sq.ft. Supply Air: 7 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 0.4 AC/hr Volume: 980.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air. 0 CFM Percent of Supply.: 4 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 80 ft./min. Percent of Supply: 5 % Runout Air Velocity: 80 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.008 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item,, Area., - 'TU7 jitg §en ---,-Clg 'La .Description, -Quantity',',�. HTM..;,,,,, Loss �.,HTM ��.,'�.Gain,-: ;--Gain-: UP-Ceil-1 6C-30 24.6 X 4 98 0.032 1.0 94 1.3 0 125 Subtotals; for Structure: 94 0 125 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 30 27 AED Excursion: 1 Room Totals: 124 0 153 rILC Rhvic-- Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie, FL 34983 —Page-22 Detailed Room Loads - Room 12 - Stairway (Peak Fenestration Gain Procedure) General_:. Room is in zone 2, which peaks at 5 pm Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 16.0 ft. System Number: 1 Room Width: 4.0 ft. Zone Number: 2 Area: 64.0 sq.ft. Supply Air: 123 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 14.4 AC/hr Volume: 512.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 0 CFM Percent of Supply.: 3 % Runout Duct Size: 7 in. Actual Summer Vent.: 6 CFM Runout Air Velocity: 461 ft./min. Percent of Supply: 5 % Runout Air Velocity: 461 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.110 in.wg./l 00 ft. Actual Summer Infil.: 1 CFM Item , -� 11 j, Area, �U,-'— Htd, Sen -CIg,:,,--,:., Lat, Sen �,,- Description --j Quantity. Value ;.HTM Loss ��,,!,,, HTM,-Gain..- Gain W -Wall-1 3A-7.5ocs 16 X 8 110 0.095 2.9 314 1.3 0 139 W -GIs-IA-hb-o shgc-0.6 2%S 18 1.070 32.1 578 109.9 0 1,978 UP-Ceil-1 6C-30 16 X 4 64 0.032 1.0 61 1.3 0 82 Subtotals for Structure: 953 0 2,199 Infil.: Win.: 2.3, Sum.: 1.2 128 0.586 75 0.156 51 20 Ductwork: 328 479 AED Excursion: 10 Room Totals: 1,356 51 2,708 C I PY Rhvdc -'Itisidential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucia, FL 34983 Page 23 �Detailed Room Loads - Room 13 - Bedroom 2 (Peak Fenestration Gain Procedure) General. Room is in zone 2, which peaks at 5 pm Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 13.5 ft. System Number: 1 Room Width: 10.7 ft. Zone Number: 2 Area: 144.0 sq.ft. Supply Air: 56 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.3 AC/hr Volume: 1,445.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: 0 CFM Percent of Supply.: 6 % Runout Duct Size: 4 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 643 ft./min. Percent of Supply: 6 % Runout Air Velocity: 643 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.464 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item Sen. ,Description !Quantity. ,Value. HTM Loss- HTM, Gain..,,- »Gairi N -Wall-1 3A7.5ocs 10.7 X 8 63.1 0.143 4.3 271 2.2 0 138 N -GIs-IA-hb-o shgc-0.6 10%S 22.5 1.070 32.1 722 29.9 0 673 UP-Ceii-16C-30 13.5 X 10.7 144.4 0.032 1.0 139 1.3 0 185 Subtotals for Structure: 1,132 0 996 Infil.: Win.: 1.5, Sum.: 0.8 86 0.584 50 0.164 34 14 Ductwork: 377 218 AED Excursion: 4 Room Totals: 1,559 34 1,232 tu rnPY Rhvac - Resi ential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie, FL 34983 Page 24 Detailed Room Loads - Room 14 - Master Bath (Peak Fenestration Gain Procedure) General ,.: . 5 ,. . _.- >> _, •. -,. ,.. - ,t: - �, - - <•• Room is in zone 2, which peaks at 5 pm Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 13.5 ft. System Number: 1 Room Width: 8.7 ft. Zone Number: 2 Area: 117.0 sq.ft. Supply Air: 46 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.3 AC/hr Volume: 1,175.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 0 CFM Percent of Supply.: 6 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 524 ft./min. Percent of Supply: 5 % Runout Air Velocity: 524 ft./min. Actual Winter Infil.: 1 CFM Actual Loss: 0.310 in.wg./l00 ft. Actual Summer Infil.: 1 CFM Htg en S Cfg , Lat Spn - ,Description, Y °> w:G2uantity Value, 4 • < HTM ;. Lyoss , HTM n Gain Gain. E -Wall-13A7.5ocs 8.7 X 8 51.6 0.143 4.3 221 2.2 0 113 E -GIs-lA-hb-o shgc-0.6 0%S (2) 18 1.070 32.1 578 30.6 0 550 UP-Ceil-16C-30 13.5 X 8.7 117.4 0.032 1.0 113 1.3 0 150 Subtotals for Structure: 912 0 813 Infil.: Win.: 1.2, Sum.: 0.7 70 0.589 41 0.158 28 11 Ductwork: 304 178 AED Excursion: 4 Room Totals: 1,257 28 1,005 Mir Rhvac - Resi ential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie, FL 34983 IV Page 25 Detailed Room Loads - Room 15 - Laundry (Peak Fenestration Gain Procedure) General _ Room is in zone 2, which peaks at 5 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 6.1 ft. System Number: 1 Room Width: 5.0 ft. Zone Number: 2 Area: 31.0 sq.ft. Supply Air: 8 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 1.6 AC/hr Volume: 305.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 0 CFM Percent of Supply.: 9 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 90 ft./min. Percent of Supply: 5 % Runout Air Velocity: 90 ft./min. Actual Winter Infil.: 1 CFM Actual Loss: 0.010 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area. -U- .. �Htg.: Sen. _ CIg: �,._ Lat, Sep; .:- Description. ,: P 15.5 � uanti Value,:..: Q tY <-HTW.?. Loss � _ : . ,. HTM, : -- - Gain Gain W -Wall-13A7.5ocs X 8 44 0.143 4.3 189 2.2 0 96 UP-Ceil-16C-30 6.1 X 5 30.5 0.032 1.0 29 1.3 0 39 Subtotals for Structure: 218 0 135 Infil.: Win.: 0.8, Sum.: 0.4 44 0.591 26 0.159 17 7 Ductwork: 78 31 AED Excursion: 1 Room Totals: 322 17 173 I ivCK, f V"', n Dv a„ - Rhvac - Resi ential & Light Commercial HVAC Loads Elite Software Development, Im Ken Humphrey Lot 2172 Nettles Islan Port Saint Lucie, FL 34983 Page 2 Detailed Room Loads - Room 16 - Walk In Closet (Peak Fenestration Gain Procedure) Room is in zone 2, which peaks at 5 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 8.0 ft. Zone Number: 2 Area: 112.0 sq.ft. Supply Air: 19 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 1.0 AC/hr Volume: 1,120.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 0 CFM Percent of Supply.: 9 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 221 ft./min. Percent of Supply: 5 % Runout Air Velocity: 221 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.057 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item Area -U- `Htg Sen. Cl NLat Sen Description _ . , _.,, ._, ty ..`,` Quanti _, ;,, ,Value`; HTMti Loss , ;,_HTM,- n Gain Gain. E -Wall-13A-7.5ocs 14 X 8 112 0.095 2.9 319 1.3 0 142 S -Wall-13A 7.5ocs 4 X 8 32 0.095 2.9 91 1.3 0 40 UP-Ceil-16C-30 14 X 8 112 0.032 1.0 108 1.3 0 143 Subtotals for Structure: 518 0 325 Infil.: Win.: 2.6, Sum.: 1.4 144 0.583 84 0.160 57 23 Ductwork: 192 75 AED Excursion: 2 Room Totals: 794 57 425 RhvTc -.' R6 sibential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucia, FL 34983 FNe 27 Detailed Room Loads - Room 17 - Master Bedroom (Peak Fenestration Gain Procedure) -Gefi6r,'61 Room is in zone 2, which peaks at i- pm' Calculation Mode: Htg. & c1g. Occurrences: 1 Room Length: 18.0 ft. System Number: 1 Room Width: 14.0 ft. Zone Number: 2 Area: 252.0 sq.ft. Supply Air: 411 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 9.8 AC/hr Volume: 2,520.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 4 Actual Winter Vent.: 12 CFM Runout Air: 0 CFM Percent of Supply.: 3 % Runout Duct Size: 6 in. Actual Summer Vent.: 21 CFM Runout Air Velocity: 523 ft./min. Percent of Supply: 5 % Runout Air Velocity: 523 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.175 in.wg./l 00 ft. Actual Summer Infil.: 2 CFM -'Wrea 513 H_t9' S pv U t I.,.'!fe De§crptior1 Quantity - Value-, TM L ,. E -Wall-1 3A-7.5ocs 14 X 8 89.5 0.095 2.9 255 1.3 0 113 S -Part-1 5*/15*-1 213-0sw 2 X 8 16 0.097 1.5 23 1.5 0 23 S -Part-1 F/I 5'-1 213-0sw 10 X 8 45 0.097 1.5 65 1.5 0 65 W -Wall-1 3A-7.5ocs 17.5 X 8 95 0.095 2.9 271 1.3 0. 120 E -GIs-IA-hb-o shgc-0.6 O%S 22.5 1.070 32.1 722 30.5 0 687 S -GIs-lA-hm-o in partition (2) 35 1.270 19.1 666 28.7 0 1,004 W -GIs-lA-hb-o shgc-0.6 2%S (2) 45 1.070 32.1 1,444 111.7 0 5,028 UP-Ceil-16C-30 18 X 14 252 0.032 1.0 242 1.3 0 323 Subtotals for Structure: 3,688 0 7,363 Infil.: Win.: 4.5, Sum.: 2.4 252 0.587 148 0.159 100 40 Ductwork: 1,224 1,598 AED Excursion: 32 Room Totals: 5,060 100 9,033 n P'v ......... ......... Rhvk -FRIsMential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Lot 2172 Nettles Island Port Saint Lucie, FL 34983 Page 28 System I Room Load Summary Ht Min M . _ .., Run Run, �r, Clg,'. r,,,,,qg Min ActRoom . Area--. Sens, Htg. _Duct,, ,., Duct,,.; Sens.,;I, Lat ,.Clg Name, SF...- -.Btuh- ­,:­CFM,,p" --Size,'.­­%;o-VeI- 'Btuh Btuh CFM," - F CFM --Zone 1-- 1 Bedroom 4 173 4,107 53 1-6 507 2,189 313 100 100V 2 Golf Cart Room 100 3,302 43 1-6 455 1,962 79 89 89v 3 Hall 63 54 1 0-0 0 0 0 0 0 V 4 Bath 2 90 702 9 1-4 54 104 24 5 5%, 5 Stairway 48 1,260 16 1-4 334 641 38 29 29V 6 Kitchen 143 1,686 22 1-7 500 2,936 335 134 134 w 7 Living 252 7,836 102 4-6 524 9,051 115 412 412" 8 Nook 60 4,370 57 1-8 458 3,511 72 160 160 Zone 1 subtotal 929 23,316 303 20,393 976 928 928 ---Zone 2- 9 Bedroom 3 229 4,833 63 1-7 675 3,375 139 154 154✓ 10 Bath 3 59 427 6 1-4 162 311 17 14 14-.1 11 Hall 2 98 124 2 1-4 so 153 0 7 7,J 12 Stairway 64 1,356 18 1-7 461 2,708 51 123 12V 13 Bedroom 2 144 1,659 20 1-4 643 1,232 34 56 56t/ 14 Master Bath 117 1,257 16 1-4 524 1,005 28 46 46%r 15 Laundry 31 322 4 1-4 90 173 17 8 8..' 16 Walk In Closet 112 794 10 1-4 221 425 57 19 19,/ 17 Master Bedroom 252 5,060 66 4-6 523 9,033 100 411 41 1'V Zone 2 subtotal 1,106 15,733 205 18,416 443 838 838 Ventilation 2,967 1,484 3,735 Duct Latent 2,106 System 1 total 2,036 42,017 608 32,362 7,260 1,406 1,405 System 1 Main Trunk Size: 12x20 in. Velocity: 843 ft./min Loss per 100 ft.: 0.094 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure + Excursion" method. Cooling.,System-Summary, Cooling ;Sensible/Latent. t Sensible- 'Latent- Total,' Tql. '50it Btuh' Btu h lit U Net Required: 3.30 82%/18% 32,362 7,260 39,622 Recommended: 3.60 75%/25% 32,362 10,787 43,150 Actual: 3.60 76%/24% 31,900 10,100 42,000 jEquipment Data ,_­,-�4^ S' Heating System Cooling System Type: CENTRAL UNIT CENTRAL UNIT Model: 25HCA342A003 OR EQUIVALENT FV413NF005 OR EQUIVALENT Brand: CARRIER CARRIER Description: HEAT PUMP AIR HANDLER Efficiency: HSPF 8.5 15 SEER Sound: Capacity: 42K BTU 42K BTU Sensible Capacity: n/a 31,900 Btuh Latent Capacity: n/a 10,100 Btuh r. I Code Compliance Division Review Comments 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 Page 1 hftp://stiucieco.gov/ce PROPERTY INFORMATION Owner(s): Address: 2173 NETTLES BLVD Charles Civiletto City / State / Zip; JENSEN BEACH FL 34957 Parcel # : 4502-501-0176-000/5 Jurisdiction: St. Lucie County Zoning: HIRD Lot # : Block: APPLICATION INFORMATION Permit Number: 0804-0159 Application Type: Master Permit w/subs Activity Type: New Other Activity: Permit Type: Building Residential (SFR) Stories: 1 Automatic Sprinkler System? CONTRACTOR INFORMATION Contractor Name: NEWMAN JAMES W Fax Number 772-232-17X' / Business Name: JWN CONSTRUCTION INC Business Addr: 1036 NE JENSEN BEACH BLVD City / State / Zil JENSEN BEACH, FL 349 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Complete Date Released Documents Missing Pending Lorie Gerstemeier 04/15/2008 1 Comment need noc at time of pickup 04/15/2008 2 Comment BEFORE ISSUING THIS PERMIT #97050126 NEED VOID LETTER FOR GLASS ROOM AND THAT THEY DEMO THE TRAILER AND REPLACED IT WITH NEW SFR 04/17/2008 3 Comment PLUMBING SUB IS ON HOLD. PLEASE CONTACT CONTRACTOR LICENSING AT 462-1672 Front Counter Review Complete Plans Examiner Review Incomplete Lorie Gerstemeier 04/15/2008 04/15/2008 Kathy Clcio F04/l/L E kme lt� Py 04/18/2008 1 Comment BOTH SETS OF FLOOR & ROOF TRUSS PLANS MUST BE SIGNED THAT THEY WERE "REVIEWED & APPROVED" BY ENGINEER OF RECORD PAUL WELCH 04/18/2008 2 Comment METAL ROOF FASTENING NOTE ON BOTH TYPICAL WALL SECTIONS ON PAGE A-4 OF PLANS QUOTE FBC 2001 EDITION - WE ARE CURRENTY UNDER THE GUIDELINES OF FBC 2004 EDITION - PLEASE CORRECT **NOTE** FBC 2007 GOES INTO EFFECT OCTOBER 1, 2008 04/18/2008 3 Comment NEGATIVE DESIGN PRESSURES FOR WINDOWS #1,0 5,018 and ARE TOO LOW FOR ZONE 5 @ 140mph, USING EXPOSURE "C" MULTIPLIER OF 1.35 FOR MEANIROOF HEIGHT OF 25' Zoning Review Complete Jodee Vorreyer 04/17/2008 04/17/2008 i. s • TRANSMISSION VERIFICATION REPORT TIME 04/18/2008 09:09 NAME FAX 4622885 TEL SER.* BROM5J411427 DATE,TIME 04/18 09:09 FAX NO./NAME 917722321744 DURATION 00:00:23 PAGE(S) 01 RESULT OK MODE STANDARD ECM code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-9553 Fax: (772) 462-2922 trttp:llstiucieco.govlcp PROPERTY INFORMATION Address: 2173 NETTLES BIND City I State / Zip; J ENSEN BEACH Parcel # : 4502-801-0178-00015 Zoning: HIRD APPLICATION INFORMATION Permit Number: 0804-0159 Activity Type: New Permit Typo: Building Residentlal (SFR) Review Comments FL 34957 Jurisdiction: St, Lucie County tat # : Block: CONTRACTOR INFORMATION Contractor Name: NEWMAN JAMES W Business Name: JWN CONSTRUCTION ING Gusiness Addr: 1036 NE JENSEN BEACH BLVD Page 1 Owner(s): Charles Civiletto Application Type: Master Permit wlsubs Other Activity: Stories: 1 Automatic Sprinkler System? U Fax Number 772-232-17 1741-f city I state I Zil ,]ENSEN BEACH, FL 349. VIEWS AND COMMENTS Review Type ALkwS Reviewed By Documents Missing Pending Lurie Gerstemeler Dale Started Date Complete Date_Rel$�d 04115/2008 1 Comment need noc at time of pickup 04/15/2008 2 Comment BEFORE ISSUING THIS PERMIT #87050126 NEED VOID LETTER FOR GLASS ROOM AND THAT r OFFICE USE ONLY: DATE FILED: 0 A REVISION FEE: PERMIT RECEIPT NO.: LQ' 0SR l 3�. ST. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING & ZONING 2300 VIRGINIA AVE► FORT PIERCE, FL 3498,1 •462-1553 . .APPLICATION FOR BUILDING P PROJECT INFORMATION 1. LOCATION!S ADDRESS: i 2. DETAILED DESCRIPTION'S OF PROJECT REVISIONS: �'�%� - 3.- CON'TRACTOR INFORMATION: ST. OF FL REGJCERT# BUSINESS NAME: ` �44') t/ Qualifiers Name: a►DDRESS: CITY: PHONE (DaYTINIE): 4. ARCHIT/tNGItiEER: e/--ej� Al DAME: ADDRESS: CITY: bf%yif�L PHONE (DAYTIME): ?7 Z.- 77,;W ST. LUCIE COUNTY CERT.-M / Q 7" 16- r-Axu r y Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucleco.gov/ce Date: 10 June 2008 Job Address: 2173 NETTLES BLVD Received By: gerstemi Paid With: CK Paid By: JWN CONSTRUCTION INC Building Receipt Sign: Receipt4: 0000063213 'ermit Number: SLC- 0804-0159 Amount: $50.00 -redit Card Number: Check Number: 9060 I