Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
OFFICE USE ONLY: Date: % I �' 01? 1 Fee Due: ST D—C Receipt# �. _.r /e Permit # 1 2. 3. 4. mi© j ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED War St. Lucie County Building and Zoning 2300 Virginia Avenue SCANNED • Ft. Pierce, FL 34982-5652 Y 772-462-1553 COLI V f� my b21� ,d ;�6S APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION LOCATION/SITE ADDRESS: 5406 Pinetree Drive Fort Pierce, FL 34982 S/DNAME: Indian River Estates SITEPLANNAME: White Residence PROPERTY TAX ID #: .-_438--602-0271-000-1 LEGAL DESCRIPTION (attach extra sheets if necessary): Indian River Estates Unit— 1 BLK 8 S 1/2 Lot 3 & all Lot 4 PLAT 6. PAGE 7. BLOCK 8 8. LOT - BOOK 1/2 3 all BOOK NO. NO. NO. of 4 PARCEL SIZE: ACRES/SQ FT. a9, Dll LOT DIMENSIONS 10. SETBACKS (ACTUAL) FRONT: BACK: h_�LRIGHT SIDE: LEFT SIDE: < 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ -NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X )0(XPOOLENCLOSURE N SG ❑ NEW XX] EXISTING 35 X 43 1505 ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X Ek OTHER: Alum. Poly ro df N ❑ NEW ❑ EXISTING 28 X 13 364 TOTAL SQUARE FOOTAGE OF CONSTRUCTION 12. VALUE OF CONSTRUCTION: $ i -c:4 i 500• CO The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 2/l9/07 d OWNER INFORMATION .� NAME: Dennis White ADDRESS: 5406 Pinetree Drive CITY: Fort Pierce STATE: FL ZIP 34982 PHONE (DAYTIlVIE): (7 ) 462-4787 email: FELL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: -- ADDRESS: " CITY: STATE: ZIP PHONE (DAYTIME): ( ) CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: BUSINESS NAME: Pioneer Screen Co Inc II QUALIFIER'S NAME: Michael J Newman ADDRESS: 1682 SW Biltmore Street CITY: Port Saint Lucie STATE: FL PHONE(DAYTIME): (772) 340-4394 FAX NO. 340-4626 ST. LUCIE COUNTY CERT #: 4763 A1' 34984 emailPione erscreenCamsn.com ARCHITECT/ENGINEER: BDQ, Inc - ADDRESS: 1950.NE 170TH Avenue CITY: Williston STATE: FL ZIP 3269.6 PHONE (DAYTIME): 0 2 ) 529-0080 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall -be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) i7S' NLY ZONING OFFICE O n Y ; f ; z > , z �`` > kfi SECTION � TOWNSHIP 5 RANGE MAP NO. Additional Yes ZONING K50 LAND USE 1 lam` LOT CVG % % s tS1 Permits no REPORT CODE T J J BIMS FEE V0 MISC FEES TOTAL FEES BITII.DING; & ZONING REVIEWt<i `S .."'.,.o.�y, � !' _ t5<. Y ti da' 1 i n.a�4 ,h Ly '< w4 rLT� � N ,..,'�v s _ . r. 2 ° k; a r r.+> r, k; • , .Ff�.�-r k w REVIEWS ZONING ZONING PLANS MISC. VEGETATION VALUE OF CONSTRUCTION REVIEWED BY EXAMINER USING ICC TABLE DATE COMPLETE 9I { 15 �f A?77 S'/� 37 3y INITIALS /(o ;W `f r% S7 I. F,- PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: C4 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLEROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4`s wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. -I understand --that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owne Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequat ondition to withstand the uplift and weight of the aluminum str re d said structure will not exceed the fooint of structure that was in existence prior to removal by the storms. �� SIGNATURE STATE OF FLORIDA COUNTY 0�3} .LLtC'� The foregoing instrument was acknowledged before me thisa7�. day of 6rCh 20, by l ji2h1s4 h Vl3 rrQ fl , who is personally known to me or who has proced �_CO (tL&f Z2 s identification. Signature of Notary Rem J (SEAL) +� g W Commission W354413 Expires October 29, 2005 IMPORTANT NOTICES: .TURF STATE OF FleQ#MA COUNTY OFc The foregoing instrument was acknowledged rrb,ifore me teYMn day of tom' , 20�by 1 �1 I , who is personally known to me or who has produced as identification. Signature of Notary (SEAL) s`�'a. Kevin i 3 rt My Commission W354413 p�Fd Expires October29, 2008 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING -FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. TER RE R EDWIN u OF .11d4P<T r— �7 IC PERh11T N[TMBFR. i osD� ©ICO NOTICE OF C0MAWNCEMENT - - -- The undersigned hereby given notice that improvement will be made to. certain real prop Florida statutes the following information is provided in the Notice of commencement erty, and in accordance with Chapter 713, 1. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO ggNUMBER.:-;->' � - (Q� _ SUBDIVISION BLOCK ? ria ` * &G —bClo-- TRACT LOB UNIT 2. GENERAL DESCRIPTION OFIMIPROVEMENT:Install Screen / Pool Enclosure 3. OWNER INFORMATION:, a. Names I1� (li1�i b. Address FO Le P. - c. interest in property d. Name and address of fee simple titleholder (if other than owner) ^4.CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: -Pioneer Screen Co Inc II 1682 SW Biltmore Street Port -Saint Lucie FL 34984 (772) 340-4993 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents maybe served as provided by Section 713.I3 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is I year from the date of recording unless a different date is specified) , 20 ` " " "' Print Name and Provide Signatory's Title/Office Owner's Authorized Officer/Director/Partner/Manager State of Florida County of (,C The foregoing instrument was acknowledged before me this / day of IL4 a 4- M ((J J By /V&iC IT. 1oki�,P as CN-rY--W—.Y-- ,"e of person) (Type of authority... e.g. Owner, officer, trustee, attorney in fact) For �1 t'Yl c� �' �Cis�(�(� �'!'� I t'1C -Tt' (Name of party on behalf of whom instrument was executed) Personally Known or produced the following type of ID: _D-L V dL2 tJ W h Kevin J Skwwt (Printed Name of Notary Public) i afore of No My Co=mWm DD3W13 gn tary Public) {,':eull or Expires Ocftw29, 2008 Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are true to the best of my knowledge and belief (section 92.525, Florida Statutes).' Signature(s) of Owner(s) or wner(s)' Authorized Officer/Director/Partner/Manager who'signed above: 0" By: -j i TZ -� I �, I LT2 Rev, osnortoot(Raommg) (S tore) y (Printed Name) i Monday, Apr 14, 2008 10:48 AM Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucleco.gov/ce Date: 14 April 2008 Job Address: 5406 PINETREE DR Received By: HUMPHREYA Paid With: ck Paid By: pioneer screen co Sign: Receipt #: 0000062119 'ermit Number: SLC- 0804-0140 Amount: $50.00 �redit Card Number: Check Number: 48591 Building Code Compliance Division Reeel'pt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 17 April 2008 Receipt #: 0000062218 Job Address: 5406 PINETREE DR 'ermit Number: SLC- 0804-0140 Received By: dimonb Amount: $80.00 Paid With: CK �redit Card Number: Check Number: 48726 Paid By: PIONEER SCREEN CO, INC Sign:, FLOOD ZONE: "AH" MAP: 12111 CO280F DATED: 8119191 SURVEYOR'S CERTIFICATE F I.HEREBY CERTIFY THAT THIS SURVEY MAP IS PER RECORD DESCRIPTION AND: IS TRUE AND CORRECT TO THE BEST ❑F MY KNOWLEDGE AND BELIEF AS SURVEYED IN THE FIELD. I FU HER CERTIFY THAT THIS SURVEY COMPLIES WITH THE MINIMUM TECH I L STANDARDS SET FORTH IN CHAPTER 61-G-17-6 BY THE FL❑RI A BOARD OF LAND SURVEYORS PURSUANT TO SECTION 472.027 FL RI kISTATUTES, AND THAT THERE ARE NO ABOVE GROUND ENCROACH NiS THER THAN SHOWN. BY, DATE+ REGISTERED LAND SURVEYOR FLORIDA REGISTRATION #4015 GEORGE M. AYLOR, JR. R.L.S. MIN. SETBACK MO. FRONT � & SIDES_ 11) CNR SIDES ®lO % REAR- J LEGAL DESCRIPTION: THE SOUTH 1/2 OF LOT 3, ALL.OF LOT 4, BLOCK 8, . INDIAN RIVER ESTATES UNIT 1, ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 10, PAGE 43, ' PUBLIC -RECORDS OF SAINT LUCIE COUNTY, FLORIDA q ADDRESS: 5406 PINETREE DRIVE FORT PIERCE, FLORIDA SURVEY NOTES: 1. NOT _ VALID UNLESS SEALED WITH AN EMBOSSED SURVEYOR'S SEAL. 2. LANDS ;SHOWN HEREON WERE -.NOT ABSTRACTED FOR RIGHTS -OF -WAY, EASEMENTS; OR OWNERSHIP. 3. LAND DESCRIPTION HEREON WAS PROVIDED BY THE CLIENT. 4. BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE. 5. -THIS -SURVEY. NOT TO BE USED FOR FENCE INSTALLATION; SPRINKLER SYSTEMS, SHRUBS, OR ANY OTHER UTILITIES WITHOUT REVERIFICATION OF PROPERTY CORNERS. 6. ELEVATIONS SHOWN HEREON ARE BASED UPON N.G.V.D. 1929. 7. SURVEY NOT COVERED BY.PR13FESSIONAL LIABILITY INSURANCE. CERTIFIED TO: f -'-- ' L 'jc. 10 Z,2 /0 ; DENNIS WHITE �D -ram ► T RIVERSIDE NATIONAL BANK OF FLORIDA, ITS j�_ LD��' SUCCESSORS AND/OR ITS ASSIGNS SAINT LUCIE TITLE SERVICES, INC. COMMONWEALTH LAND'TITLE LEGEND, FIELD WORK COMPLETED+ ■ -FOUND CONCRETE MONUMENT R -FOUND IRON ROD f O -SET IRON ROD McINTOSH AND ASSOCIATES BOUNDARY SURVEY EL -CENTER LINE SURVEYING _A MAPPING FFE -FINISH FLOOR ELEVATION PREPARED ON THE ORDER ❑Fi PSM -PROFESSIONAL SURVEYOR 325 SW SOUTH QUICK CIRCLE RIVERSIDE NATIONAL BANK AND MAPPER PORT ST. -LUCIE, FLORIDA 34953 ; R/W PC -RIGHT-OF-WAY -POINT �F CURVE (772)878-7568 (off Ice &fax) DRAWN. BY, FILE N❑.+D -DELTA ANGLEA -ARC LENGTH CERTIF. OF AUTHORIZATION NO. LB7332 LSCALE, 40': CGM 08-007-014 Arj OHO -TYPICAL ELEVATION OVERALL DESIGN COHf=LIES WITH .THE 2b0& AMENDMENTS TO THE F,B,C, 2004 51JILDING CODE, FOR 140 MPH WIND LOAD (3-SECOND GUST), FOR EXPOSURE CATEGORY "B° V 4' HEIGHT 1' 3' HEIGHT V 0' HEIGHT ® TH15 SYMBOL REFREBENT5 REAM 5PLICE LOCATIONS THIS SYMBOL REPRE51=NT8 DIAGONAL` 13 WIND BRACING (IN BOTH THE ROOF AND WALLS), 2 x 2 x .093 TUBE MAIL. 25' 9' OVERALL 12' 10' COLUMN - 12' 11' COLUMN BP CING SPACING EXIST. HOST 5TRUCT. (BELOW) LU -- 3x3xlia'GOL I 2 x 9 LIGHT WALL (4 PLACES) I U CARRIER BM. (CONT) I �, N 2 x 9 HEAVY WALL I QI CARRIER BM. (CONT) 12' 11' COLUMN 12' 11' COLUMN 16' 1' COLUMN SPA SPACING SPACING I DESIGN NOTES: I. ALL DIAGONAL 5RACING SHOWN IN BOTH THE ROOF AND WALLS SHALL 5E 2 x 2 x .093 TU5E MATERIAL, 2. 18 x 14 MESH SCREEN IS THE MAXIMUM ALLOWA3LE DENSITY FOR THIS ENCLOSURE'S DESIGN. 3, DOOR(S) MAY BE PLACED INTO ANY SCREEN WALL PANEL EXCEPT FOR THOSE THAT CONTAIN DIAGONAL 1 RACING. T t`29 4 o3 0 2 r-0R Ec.T. ' A' AND V DETAILS AND SPEC.'6 2 x 9 HVY. WALL CARRIER BEAM EXTEND$ ALL THE WAY TO THIS SCREEN WALL TO SUPPORT THE SCREEN ROOF STRUCTURE APPROX. 1' 4' ABOVE THE FASCIA OF THE HOST STRUCTURE. 1' 3' HEIGHT I x 2 IX'l 1 2x3x.010 — 2x3x.010 LLI e _ elu CIA (P m � m � ( 4 m 61 it m QQ (X 01 CIA x�zxzx x$$� N XN N x� N x cn �O z x "' 2x3x.0106 �2x3x-01 x N < J / ND CIA Q X cq x rn 110, 110. 1' 2' 1121 1. 110, �2 `4' OVERALL ENCLOSURE WIDTH ----------------- Ix2 X - X (TYP) X X X N N N N N 2x3xD10 x2 CONCEALED FASTENS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ®RCER TO COMPLY WITt141 AWMA1169 ME& 2 N' N ,h 91 J W 0 F m W Q °'03 zLz O ®W a aNZ �1 No � Z PIONEER SCREEN CO., 11 SCREEN ROOF / ALUM. ROOF ENCLOSURE FOR: X WHITE RESIEEDEENCEE , z 540(o PINE: TREE Did. FORT PIERCE, FLORIDA SHEET i OF �❑ co 0o N oN0 mco� o � cv) a(0Z�o n 0 ND,mo b Lj Do Q o O.. J O ❑ a 0 Iy wLoC`3 w ❑ Z Z Ono 0 IL OVERALL DESIGN COMPLIES UJItH THE 200(o AMENDMENTS TO THE F.B.G. 2004 BUILDING CODE, FOR 140 MPH WIND LOAD (3-6ECOND GUST), FOR EXPOSURE CATEGORY "B" PIONEER SCREEN CO., II SCREEN ROOF / ALUM. ROOF ENCLOSURE FOR; WHITE RESIEDENCE . 5406 PINE TREE DR. FORT FIERCE, FLORIDA SHEET 3 OF 3 2 x 2 x .12E ANGLE CLIP (CUT 2-INCHES LONG), W/ FOUR (4) #12 TEKS INTO THE SIDE OF THE SCREEN ROOF BEAM AND ONE (1) 3/6' DIA. THRU BOLT (W/ WASHERS) PASSING THROUGH THE ANGLE CLIP AND THE CARRIER BEAM, TYP. ONE ANGLE CLIP ON EACH SIDE OF THE TOP OF THE ROOF BEAM (AS SHOWN) 2 x 2 x .125 ANGLE CLIP (GUT 2-INCHE5 a, LONG), W/ FOUR (4) 012 TEKS INTO THE SIDE OF THE SCREEN ROOF BEAM AND }- ONE (1) 3/5' DIA. THRU BOLT (W/ WASHERS) ut PASSING THROUGH .THE ANGLE CLIP AND THE CARRIER BEAM, TYP. ONE ANGLE CLIP ON EACH SIDE OF THE BOTTOM OF tHE x ROOF BEAM (AS SHOWN), TO BE EVEN WITH R THE BOTTOM OF THE 2 x 9 CARRIER BEAM per._. SEE SHEET "3 OF 7 FOR SPECIFICATIONS ON STITCH SCREWS FOR THE CARRIER BEAMS. 2 x 2 x .125 ANGLE CLIP (CUT 2' LONG) W/ FOUR (4) 12 TEKS INTO SIDE OF ROOF BEAM AND ONE (U q4 x I' TEKS (PER ANGLE CLIP) THRU GUTTER AND INTO 'Z' GUTTER INSERT (TYP. ONE ANGLE CLIP ON EACH SIDE OF EACH COLUMN) DESIGN NOTES: I. ALL DIAGONAL BRACING SHOWN IN BOTH THE ROOF AND WALLS SHALL BE 2 x 2 x .093 TUBE MATERIAL. 2. 18 x 14 MESH SCREEN IS THE MAXIMUM ALLOWABLE DENSITY FOR THIS ENCLOSURE'S DESIGN. 3. DOOR(S) MAY BE PLACED INTO ANY SCREEN WALL PANEL EXCEPT FOR THOSE THAT CONTAIN DIAGONAL BRACING. 2 x 9 5GREEN ROOF BEAM' (TYP.) 5' STRUCTURAL GUTTER (CONT.) I x 2 SCREEN FRAME (TYP) THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH A" AFIRWOW4 Moat 3 x 3 x k8' COLUMN (BEYOND) 2 x 9 HEAVY -WALL CARRIER BEAM (CONT.) 8-INCH LONG 025 THICK) EXTRUDED "Z' GUTTER INSERT, TYP CENTERED ON EACH 3 x 3 COLUMN, WITH FOUR (4) *12 TEKS THRU TOP LIP OF GUTTER 1/4' x 21/4' LAGS, THREE (3) IN EACH 8-INCH INSERT AND AT 24' O.G. (MAX. SPACING) IN THE REST OF THE GUTTER (PILOT DRILL FASCIA W/ 5/32' BIT TO AVOID SPLITTING) 2 x HOUSE FASCIA (SEE 'FASCIA REINFORCEMENT' NOTE ON SHEET 05 OF & OF THE SCREEN ROOF ENGINEERING SHEET FOR SPECIFICATIONS ON THE REINFORCEMENT OF THE FASCIA BOARD) I x 2 x .093 ANGLE SPACER (FOR ANGLED FASCIA BD. ATTACHMENT), ATTACHED W/ TWO (2) ROWS OF �O TEK5 (STAGGERED), EACH ROW AT 18' O.C. (MAX. SPACING) NOTE: ALL 3 x 3 x i/s" COLUMNS SHALL BE ACHORED TO CONCRETE UTILIZING 'ANCHOR Pi TAIL "I' AS SHOWN ON SHEET 1'(o OF 7 OF THE ALUMINUM ROOF ENGINEERING SHEET, CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBIUTY OF THE CONTRACTOR OF RECORD 13 0 c0 m co �] o N r, co cq m co u-9z C� o rn o aN.o1- pN� -N� Nczoi cLooO 13 0 J O Ll1 Q Z ou QUO- . o 0 a Q J Q T a U in gw to z o13 Z. Z Oa 4w to J U. OVERALL DESIGN COMPLIES WITH THE 2006 AMENDMENTS TO THE F.B.C. 2004 BUILDING CODE, FOR 140 MPH WIND LOAD (3-SECOND GUST), FOR EXPOSURE CATEGORY "B° SEE SHEET 01 OF -I SIZE AND SPACING 0 2 x 2 x .125 ANGLE (CONT. , }- ATTACHED. TO 2 x 8 CARF w W/ 014 TEKS 6 18- INCHE5 C (MAX. SPACING). AL50 NC AT EACH. COLUMN, THE TO X BOLT SHALL ALSO PASS 0 THIS CONTINUOUS ANGLE l IL SEE SHEET 03 OF I FOR Sf ON STITCH SCREWS FOR TI BEAMS. 2 x 2 x .125 ANGLE CLIP (CUT 2' LONG) W/ FOUR ( 12 TEKS INTO SIDE OF R BEAM AND ONE (1) *14 x TEKS (PER ANGLE CLIP, THRU GUTTER AND INTO GUTTER INSERT (TYP. Oi ANGLE CLIP ON EACH 5.�.. OF EACH COLUMN) PIONEER SCREEN CO., II SCREEN ROOF / ALUM. ROOF ENCLOSURE FOR. WHITE RESIEDENCE 5406 PINE TREE DR. FORT PIERCE, FLORIDA SHEET 2 OF 3 GUTTER (CONT.) DESIGN NOTES: - - - 1. ALL DIAGONAL BRACING SHOWN IN BOTH THE ROOF AND WALLS SHALL BE 2 x 2 x .093 TUBE MATERIAL. 2. 18 x 14 MESH SCREEN IS THE MAXIMUM ALLOWABLE DENSITY FOR THIS ENCLOSURE'S DESIGN. 3. DOOR(S) MAY BE PLACED INTO ANY SCREEN WALL PANEL EXCEPT FOR THOSE THAT CONTAIN DIAGONAL BRACING. ° "'^"' "t"'^ A UMINUM ROOF PANELS, AND 1-1-5. DENSITY (TYP) :U 5OLT5, W1 WASHERS, TYP. =R EACH COLUMN TO CARRIER =CTION (TYP., AS SHOWN) '.125 THICK) EXTRUDED PERT, TYP CENTERED ON )LUMN, WITH FOUR (4) M2 P LIP OF GUTTER '44' x 21/4' LAG5, THREE (3) IN EACH 8-INCH INSERT AND AT 24' O.C. (MAX. SPACING) IN THE REST OF THE GUTTER (PILOT DRILL FASCIA W/ 5/32' BIT TO AVOID SPLITTING) IOUSE FASCIA (SEE 'FASCIA REINFORCEMENT' ON SHEET S OF (o OF THE SCREEN ROOF JEERING SHEET FOR SPECIFICATIONS ON THE =ORCEMENT OF THE FASCIA BOARD) ,E SPACER (FOR ANGLED FASCIA BD. ATTACHMENT), ATTACHED W/ TWO (2) ROWS OF 10 TEKS (STAGGERED), EACH ROW AT IS' O.C. (MAX. SPACING) NOTE: ALL 3 x 3 x is' COLUMNS SHALL BE ACHORED TO CONCRETE UTILIZING 'ANCHOR DETAIL #V AS SHOWN ON SHEET 06 OF 7 OF THE ALUMINUM ROOF ENGINEERING SHEET. v ui /� �❑ co �( J� cm,-' coN m o0 o0 0 acoZcm- p c\j N��O ❑ F- (5 OwLL ¢ (o ZQCDu- . CO ❑ J o ir o L9 U Q r , o LL ui Lcj ❑ zyw mooLo LL OVERALL DESIGN COMPLIES WITH THE 200(o AMENDMENTS TO THE F.B.C. 2004 BUILDING CODE, FOR 140 MPH WIND LOAD (3-5ECOND GUST), FOR EXPOSURE CATEGORY "B" PIONEER SCREEN CO., 11 SCREEN ROOF / ALUM. ROOF ENCLOSURE FOR: WHITE RESIEDENCE 540(o PINE TREE DR, FORT PIERCE, FLORIDA SHEET 3 OF 3 2 x 2 x .125 ANGLE CLIP (CUT 2-INCHE5 —� LONG), UJ/ FOUR (4)'112 TEKS INTO THE SIDE OF THE SCREEN ROOF BEAM AND ONE (1) 3/6' DIA. THRU BOLT (W1 WASHERS) PASSING THROUGH THE ANGLE CLIP AND THE CARRIER BEAM, TYP. ONE ANGLE CLIP ON EACH SIDE OF THE TOP OF THE ROOF BEAM (AS SHOWN) 2 x 2 x .125 ANGLE CLIP (CUT 2-INCHE6 �p LONG), UJ/..FQUR (4) 012 ,TEKS INtO;.THE 51D1= • OF THE SCREEN. ROOF BEAM AND ONE (1) 3/6' DIA. THRU,POLT (W/:WASHERS) w PASSING THROUGH THE ANGLE CLIP>AND THE CARRIER qm, vTp. ONE ANGLI=CLIP ON EACH SIDE OF THE. BOTTOM OF. THE X ROOF BEAM (AS SHOWN), TO BE E_YEN WITH THE BOTTOM OF THE 2 x 9 CARRIER BEAM d SEE SHEET 031WS01 i FOR SPECIFICATIONS ON 'StITCH,SCREFOR THE CARRIER ---- BEAMS. 2. x 2 x .125 ANGLE CLIP (CUT 2' LONG) W/ FOUR (4) 12 TEKS INTO.$IDE OF ROOF BEAM AND ONE' (1).14 x I' TEKS (PER ANGLE CLIP) THRU GUTTER AND INTO 'Z' GUTTER INERT (TYP. ONE ANGLE CLIP -ON EACH SIDE OF EACH COLUMN) . DESIGN NOTES: 1. ALL DIAGONAL BRACING SHOWN IN BOTH THE ROOF AND WALLS SHALL BE 2 x 2 x .093 TUBE MATERIAL. 2. 18 x 14 MESH SCREEN IS THE MAXIMUM ALLOWABLE DEN61TY FOR THIS ENCLOSURE'S DESIGN. 3. DOOR(S) MAY BE PLACED INTO ANY SCREEN WALL PANEL EXCEPT FOR THOSE THAT CONTAIN DIAGONAL BRACING. 2 x 9 SCREEN ROOF BEAM (TYP.) 5' STRUCTURAL GUTTER (CONT.) I x 2 SCREEN FRAME (TYP) 3 x 3 x %' COLUMN (BEYOND) &-INCH LONG 025 THICK) EXTRUDED 7' GUTTER INSERT, TYP CENTERED ON EACH 3 x 3 COLUMN, WITH FOUR (4) 012 TEKS THRU TOP LIP OF GUTTER 1/4' x 21i4.' LAGS, THREE (3) IN EACH 8-INCH INSERT AND AT 24' O.C. (MAX. - SPACING) .IN THE REST OF T14E GUTTER (PILOT DRILL FASCIA UJ/ 5/32' BIT TO AVOID SPLITTING) 2 x HOUSE FASCIA (SEE 'FASCIA REINFORCEMENT' NOTE ON SHEET #5 OF (o OF THE SCREEN ROOF ENGINEERING SHEET FOR SPECIFICATIONS ON THE REINFORCEMENT OF THE FASCIA BOARD) 1 x 2 x .093 ANGLE SPACER (POP, ANGLEb FASCIA. BD. ATTACHMENT), ATTACHED UJ/ TWO (2) ROWS OF 10 TEK5 (STAGGERED), EACH ROW AT IS' O.G: (MAX. SPACING) NOTE';: ALL 3 x 3 x k8' COLUMNS SHALL BE ACHORED TO CONCRETE UTILIZING 'ANCHOR DETAIL 01' A5 SHOWN ON SHEET "to OF i OF THE. ALUMINUM ROOF ENGINEERING SHEET. �o rn co �� J) `J N CO r � 00 pnn 3co�Oz 0 OL (D a No lq� �N�mo ❑ L< O� w Z LL a00o v-=o�2. no o Ca�� V J F rr LU N U 4 r. ,q noZ=w u Lij cy) 0 moo� ° g FAE31RICATION / INSTALLATION REQUIRED GUIDELINES NOTE: ANY J055 THAT REQUIRE 51TE-6PECIFIC DE516N / ENGINEERING MUST BE 5U5MITTED TO THE ENGINEER OF RECORD FOR 5UCH DESIGN CONSIDERATION PRIOR TO THE JOB BEING PERMITTED, FABRICATED OR INSTALLED. LEAD-TIME5 FOR 5UCH WORK WILL DEPEND ON OUR CURRENT WORK LOAD AT ANY GIVEN TIME. THE ITEMS BELOW ARE NOT PERMITTED ON ANY ENCLOSURE WITHOUT SITE -SPECIFIC DESIGN 4 AUTHORIZATION FROM THE ENGINEER OF RECORD, I. NO SCREEN ROOF BEAMS SHALL BE LOCATED WITHIN 12-INCHES OF ANY OUTSIDE CORNER OF ANY WALL, FASCIA OR STRUCTURAL GUTTER. 2. NO CABLE BRACING SHALL BE USED ON ANY ENCLOSURE AT ANY TIME FOR THE RESISTANCE OF ANY IMPOSED DESIGN LOADING. 3. THERE SHALL BE NO SUBSTITUTION OF EITHER CONCRETE ANCHOR TYPE OR MANUFACTURER OTHER THAN THOSE SPECIFIED ON THESE ENGINEERED DESIGN DRAWINGS. 4, THERE SHALL BE NO SCREENING UTILIZED THAT IS FINER THAN IS x,14 MESH SCREEN WITHOUT SITE -SPECIFIC DESIGN (THAT SHALL BE DONE PRIOR TO THE JOB BEING FABRICATED OR INSTALLED) WITH JOB DRAWINGS BEARING THE ENGINEER OF RECORDS ORIGINAL SIGNATURE (IN BLUE INK) UNDER HIS EMBOSSED SEAL. 5. ALL SCREEN ROOF ENCLOSURES MUST BE POSITIONED ON THE ED6E5 OF THE CONCRETE DECK 50 THAT THE CUTER SURFACE OF THE SCREEN FRAME IS NO LESS THAT 2 3/4 - INCHES IN FROM THE EDGE, TO CREATE PROPER EDGE DISTANCE FOR THE SPECIFIED CONCRETE ANCHORS AT THE BASE OF EACH COLUMN. Co. ALL ROOF PURLINS IN THE ROOF AND CHAIR RAILS IN THE WALLS 5HALL NOT EXCEED 8-FEET CENTER - TO - CENTER SPACING (SEE APPROPRIATE DETAILS ON OTHER SHEETS OF THIS DRAWING FOR SPECIFIED MATERIAL SIZES REQUIRED FOR ANY GIVEN APPLICATION. 1. NO SCREEN ROOF ENCLOSURE SHALL. BE INSTALLED UTILIZING SEVEN-INCH STRUCTURAL GUTTER, AS IT 15 NOT PERMITTED, OR STRUCTURALLY ADEQUATE UNDER THIS ENGINEERING. THE ITEMS BELOW MUST BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO MEASURING 4 LAYOUT, FABRICATION OR INSTALLATION FOR THE REQUIRED SITE -SPECIFIC DESIGN. I, ANY SCREEN ROOF ENCLOSURE THAT UTILIZES ROOF BEAMS THAT EXCEED 40-FEET IN SPAN, AT ANY POINT ON THE ENCLOSURE. 2. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES WALL COLUMNS (UPRIGHTS) THAT EXCEED 12-FEET IN HEIGHT AT ANY POINT ON THE ENCLOSURE. 3. ANY ENCLOSURE THAT UTILIZES ANY, CARRIER BEAM,(A BEAM THAT ACTS AS SUPPORT FOR ANY OTHER SCREEN ,ROOF BEAM) AT ANY POINT ON THE ENCLOLSURE. NO CARRIER BEAM SHALL BE PERMITTED TO BE MOUNTED TO THE FASCIA OF ANY HOST STRUCTURE (AS PRIMARY 50F?ORT), 4. INSTALLATION OF ANY SCREEN ROOF ENCLOSURE ON AN EXISTING HOUSE FASCIA WHERE•TNE OVERHANG EXCEEDS 2-FEET. NOTE THAT IF THE EXISTING- RESIDENCE WAS CONSTRUCTED UNDER ANY BUILDING CODE PRIOR TO F.B.C. 2001, THE JOB MAY REQUIRE FOURTH -WALL TYPE CONST., AS THERE 15 NO WAY TO CERTIFY THE ABILITY OF A HOST STRUCTURE THAT WAS ONLY BUILT TO WITH- STAND 110 MPH WIND LOADS OR LESS, (AS WAS REQUIRED UNDER PREVIOUS BUILDING CODES) TO RE515T THE IMPOSED LOADS OF AN ENCLOSURE THAT 15 DESIGNED TO WITHSTAND THE LOADS IMPOSED UNDER THE 140 MPH WIND LOAD SPECIFIED IN THE CURRENT BUILDING CODE. SNAP / LAP JOINT �j CONNECTION NOTE: ALL FRAMING MEMBER5 ON ANY ENCLOSURE THAT UTILIZE SNAP OR LAP JOINT IN THEM SHALL HAVE *12 TEKS INSTALLED THRU THE SNAP OR LAP CONNECTION AT 18 INCHES ON CNTR. (TYP). THESE TEK SCREWS ARE -TO RE- PLACED ON BOTH EDGES OF THE UPRIGHT (BOTH THE INNER AND THE OUTER EDGE) IN ALL CASES. THI5 SPECIFICATION APPLIES TO UPRIGHTS AND BEAMS BOTH. MINIMUM FOOTER TAE3LE5 ONO MAX. 'BM. FOOTER SPAN 8' X 8, WITH lU 050 CONT. UP TO 38' 8'x12'WITH (1) SO CONT. UP TO 41' 10' x 12' WITH (1) p50 CONT. UP TO 48' 12' x 12' WITH (2) 050 CONT UP TO 55' ISOLATED MAX. BM, FOOTER(') SPAN 12' x 12' WITH (2) 050 CONT. UP TO 30' 12' x IV WITH 31' TO 39' (2) -50 CONT. 14' x l6' WITH 40' TO 44' (2) 050 CONT. 16' x lb'WITH 44' TO 52' (2) 050 CONT. IF A JOB EXCEEDS THESE PARAMETERS, THE FOUNDATION MUST BE SIT(=-SpEGIFICALLY DFSIGNI P BY THE ENGINEER MONOLITHIC FTG. LOAD CAPACITIES ARE BASED ON A MIN. OF 3 FEET OF CONT. CONCRETE, 2,500 PSI MINIMUM, W/ WIRE OR FIBERMESH REINFORCEMENT ()ISOLATED FOOTERS MAY BE USED ON EDGE OF EXIST, CONC. SLAB OR UNDERNEATH THE PERIMETER CF BRICK PAVER DECK (ALL SIDES) THE ENGINEERR OF RECORD WILL NOT BE ABLE TO CERTIFY THE STRUCTURAL. INTEGRITY OF ANY EXISTING CONCRETE DECK / FOOTINGS THAT WERE INSTALLED WITHOUT PERMITS, AS THERE „WOULD BE NO RECORDS TO VERIFY CONCRETE THICKNESS', FOOTER SIZES AND THE 51ZE AND QUAN1'IT1''OF STEEL RE -BARS THAT WOULD BE REQUIRED UNDER THE CURRENT BUILDfNG CODE STANDARDS, SCREW SPACING AND EDGE DISTANCE SPEC.'S THIS TABLE IS BASED ON THE PROPERTIES OF C-1022 LOW CARBON STEEL SMS AND SELF -DRILLING (TEK) SCf EWS, WHICH ARE AN INDUSTRY STANDARD SCRFW. SCREW SIZE NOMINAL SCREW DIAMETER (IN:) MIN. EDGE DISTANCE MIN, CENTER -TO - CENTER DISTANCE NS m.156 5/16 ° i/I� �10 m.188 3/8' I/2' 012 0.2n 1/2' 5/0, 014 0.250 INTERNAL CONNECTION SPECIFICATION (UTILIZING SCREW BOSSES) ALL INTERNAL- CONNECTIONS UTILIZING THE EXTRUDI=D SCREW 5055E5 SHALL HAVE 010 SMS SCREWS, WITH A MINIMUM EMBEDMENT INTO THE SCREW 13055 OF 1 3/4" (UNLESS OTHERWISE SPECIFIED ON ANY CONNECTION DETAIL). ALL SCREW 8055F6 IN A GIVEN EXTRUSION MUST BE FILLED (EXAMPLE: THE 2 x 3 x .010 CHAIR RAIL / ROOF PURLIN THAT HAS SIX SCREW BOSSFS, MUST HAVE SIX OF THESE #10 SMS SCREWS INSTALLED AT EACH END OF THAT COMPONENT, AT EACH CONNECTION), SCREEN PANEL INSTALLATION SPECIFICATION: PLEASE NOTE THAT ALL SCREEN PANEL OPENINGS (BOTH ROOF AND WALLS) SHALL BE INSTALLED ON ALL FOUR SIDES WITH SPLINE (INDEP- ENDANT OF ALL SURROUNDING PANELS). THE ONLY FRAMING COMPONENTS THAT ARE -NOT REQUIRED TO HAVE SPLINE INSTALLEP IN THEM ARE ALL OF THE DIAGONAL WALL AND ROOF BRACING. CONCRETE ANCHOR SPECIFICATIONS: ALL CONCRETE ANCHORS SPECIFIED ON THIS DETAIL.own SHEET ARE MANUFACTURED BY 'RED HEAD' ANCHORING SYSTEMS, AS ALL. LOAD CAPABILITIES ARE RASED ON o TEST DATA FURNISHED BY RED HEAD IN THEIR PRODUCT C) AND RESOURCE BOOK. NO SUBSTITUTIONS OF ANY OTHER MANUFACTURER'S CONCRETE ANCHORS 15 PERMITTED WITHOUT SUBMITTAL OF THE COMPANY'S TEST DATA (TO VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN, L= o oc SIGNED AND SEALED LETTER OF AUTHORIZATION FROM THE ENGINEER OF RECORD. ANY UNAUTHORIZED ANCHOR SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH z THIS DESIGN. THE ANCHORS TO BE USED FOR APPLICATIONS zi (D _w SPECIFIED IN THIS ENGINEERING DESIGN PLAN ARE AS Xd6wW FOLLOWS: F'n ni o 1/4' DIA FASTENERS: REDHEAD ITW TAPCON (SEE INDIVIDUAL DETAILS 90 E FOR MINIMUM. EMBEDMENT DEPTH INTO CONCRETE) e-�j I Lu 3/8' DIA. FASTENERS: 3/8' TRU BOLT WEDGE ANCHOR (SEE INDIVIDUAL BE "' < DETAILS FOR QUANTITY OF FASTENERS NEEDED) CDca (MINIMUM EMBEDMENT SHALL BE 3' INTO CONCRETE L UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) 3/6' LARGE DIAMETER TAPCON (LDT) (SEE INDIVIDUAL =3 o DETAILS FOR QUANTITY OF FASTENERS NEEDED) O o (MINIMUM EMBEDMENT SHALL BE 2112' INTO CONCRETE UNLE55 OTHERWISE SPECIFIED IN ANY DETAIL) u = o v c FOR BRICK PAVER INSTALLATION: DESIGN DISCLAIMER FOR INSTALLATION ON A BRICK PAVER DECK, THE ONLY FASTENERS THAT WILL MEET THE DESIGN CRITERIA INDICATED WITHIN THESE DESIGN SPEC.'S ARE THE RED HEAD TRU BOLT WEDGE ANCHOR (3/8' x i'), WHICH BASED ON I/8' ANGLE, I x 2 O.B., 21is" THICK BRICK PAVER AND A MAXIMUM MORTAR BED THICKNESS OF 3/4', THIS SCENARIO WILL STILL MEET THE MINIMUM FASTENER EMBEDMENT. IF ANY OF THESE CONTRIBUTING FACTORS EXCEED THE DIMENSIONAL- BREAKDOWN INDICATED, THE JOB MUST BE PRESENTED TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC ANCHORING DESIGN. EXIST. HOUSE FASCIA NOTES: IT SHALL BE THE RESPONSIBILITY OF THE .INSTALLING CONTRACTOR TO INSPECT AND INSURE THE CONDITION OF THE EXISTING FASCIA, TO DETERMINE IF IT 15 IN GOOD ENOUGH CONDITION TO SUPPORT THE PROPOSED SCREEN ENCLOSURE (PRIOR TO ITS INSTALLATION) THERE 15 NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IN THIS ENGINEERING DESIGN DOCUMENT REGARDING THE ABILITY OF ANY HOST STRUCTURE TO RESIST THE BUILDING CODE SPECIFIED DESIGN LOADS IMPOSED BY ANY PROP05ED SCREEN ENCLOSURE. SUCH CERTIFICATION WILL BE DEPENDENT ON AVAILABILITY OF ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS, AS WELL AS ORIGINAL PERMIT AND INSPECTION RECORDS FOR THE HOST STRUCTURE. CERTIFICATION OF THE HOST STRUCTURE, IF IT IS REQUIRED, WILL ULTIMATELY BE POSSIBLE ONLY IF THESE RECORDS CONTAIN ALL THE INFORMATION NEEDED BY THE ENGINEER TO PERFORM ALL OF THE NECESSARY 'ANALYSIS TO DETERMINE IF SUCH CERTIFICATION 15 EVEN POSSIBLE. Z .� LU 0- LL LuW �-. � 0 Lu c LIA co 0F�.e.. ' 1 GENERAL N®TE5 AND IDE51GN PARR ETER& I. THE OVERALL. DESIGN COMPLIES WITH THE 2006 AMENDMENT TO THE FLORIDA BUILDING CODE 2004 (CHAPTER I(o AND 20), AND 15 BASED ON THE FOLLOWING PARAMETERS: A. WIND SPEED: 140.M.P.H., 3-SECOND GUST B. EXPOSURE CATEGORY 'B' C. DE516N PRESSURES AS FOLLOWS: a) SIMULTANEOUS WIND LOADING 9 (b P.SF. FOR SCREEN ROOF AND 21 RSR FOR SCREEN WALLS b) 300 LR LOAD APPLIED VERTICALLY DOWNWARD ALONG ANY ONE FOOT (12-INCHES) OF ANY PRIMARY MEMBER (EXCLUDING DIAGONAL WIND BRACING, WHICH IS TREATED AS A 'STRUCTURAL MEMBER' UNDER 2006 AMENDMENT DEFINITIONS. D. MAXIMUM ENCLOSURE HEIGHT SHALL NOT EXCEED 30-FEET E. ALLOWABLE DEFLECTION OF 'L / 60% AS SPECIFIED I TABLE 019>10.1, FOR NON -HIGH VELOCITY HURRICANE ZONES. F, CONTINUOUS LOAD PATH 15 PROVIDED, 2. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD): A. ALL EXTRUSIONS SHALL BE ALUMINUM ALLOY %063-T6 (NOTE THAT THE SPLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALLOY 060(o1-T6, IF THIS MATERIAL IS MORE READILY AVAILABLE TO THE CONTRACTOR) (SEE COMPONENT SHAPES AND SIZES AT RIGHT). B. FASTENERS SHALL BE ALUMINUM ALLOYS 2024-T4 4 1015-T6„DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL, OR 300-SERIE6 STAINLESS STEEL, IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE APPROPRIATE MEANS FOR SEPARATION OF D1551MILAR MATERIALS AS THEY ARE DEFINED IN SECTION 02003.8.4. THE CONTRACTOR MAY IMPLEMENT ANY OF THE MEANS SPECIFIED IN THIS SECTION. ANY ALTERNATIVE MEANS MUST BE ACCOMPANIED BY A LETTER OF CERTIFICATION FROM THE PRODUCT'S MANUFACTURER (THIS LETTER MUST BE 51GNED AND SEALED BY A FLORIDA LICENSED STRUCTURAL ENGINEER), WHICH STATES THAT THEIR PRODUCT MEETS / EXCEEDS ALL OF THE REQUIREMENTS SPECIFIED IN THE ABOVE - LISTED SECTION. THIS LETTER SHALL ALSO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD FROM B.D.Q., INC. C. SCREEN CLOTH SHALL BE VINYL COATED, WOvEN FIBERGLASS, MAXIMUM DENSITY OF 18 x 14 (58% OPEN). 3. ALL FASTENERS THAT PASS THROUGH ANY EXTRUSION INTO CONCRETE, MASONRY, WOOD, STEEL, ALUMINUM OR ANOTHER EXTRU51ON SHALL HAVE A 5/6-INCH DIAMETER WASHER, MINIMUM (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD), AND SHALL BE NO MORE THAN 18-INCHES CENTER - TO - CENTER SPACING. 4. ALL FASTENERS ADJACENT TO UPRIGHTS THAT DO NOT REQUIRE REINFORCING ANGLE CLIPS, SHALL BE PLACED WITHIN TWO (2) INCHES OF THAT UPRIGHT ITYP. FOR BOTH SIDE5). S. SCREEN DOOR(S) MAY BF LOCATED IN ANY SCREEN WALL PANEL, EXCEPT FOR THOSE THAT CONTAIN DIAGONAL WiND i3RAc iNG CK-BRACING'). ALL DOORS SHALL BE SELF -CLOSING AND SELF -LATCHING. DOORS INSTALLED IN AN ENCLOSURE THAT SURROUNDS A POOL / SPA SHALL HAVE DOOR LATCHES INSTALLED FIVE (5) FEET ABOVE THE FLOOR, MINIMUM. 6. COPIES OF THIS ENGINEERING SPECIFICATION / DESIGN DETAIL ARE TO ONLY BE CONSIDERED VALID FOR PERMITTING OR DESIGN CERTIFICATION PURP08EO WHEN ALL SHEETS OF ANY SUBMITTED SET BEARS THE ENGINEER'S ORIGINAL SIGNATURE (IN BLUE INK), UNDER HIS EMBOSSED SEAL. B.D.Q., INC. SHALL NOT BE RESPONSIBLE FOR NON -ORIGINAL COPIES THAT ARE SUBMITTED, THAT HAVE ANY UNAUTHORIZED CHANGES, ALTERATIONS OR DELETIONS ON THEM. 1. THESE ENGINEERING DETAIL DRAWINGS ARE ONLY VALID IF THE DATE ACCOMPANYING THE ENGINEER'S ORIGINAL SIGNATURE IS LE55 THAN 90 DAY5 OLD. NO BUILDING OFFICIAL OR BUILDING DEPARTMENT SHOULD ACCEPT COPIES THAT ARE OLDER THAN THIS, AND SHOULD REQUEST THE SUBMITTING CONTRACTOR OBTAIN UPDATED / CURRENT ENGINEERING. 8. ALL ENGINEERING SPECIFICATIONS AND DETAIL DRAWING CONTAINED WITHIN THIS ENGINEERING DOCUMENT ARE THE SOLE PROPERTY OF B.D.Q, INC. ANY UNAUTHORIZED COPYING OR OTHER REPRODUCTION IN PART OR WHOLE OF THESE DOCUMENTS WILL NOT BE PERMITTED AND WILL BE PROSECUTED TO THE FULLEST EXTENT ALLOWED BY LAW, S, THERE SHALL BE NO REDISTRIBUTION OF THESE ENGINEERING DOCUMENTS BY THE PER60N OR COMPANY THAT ORIGINALLY PURCHASED SIGNED AND SEALED COPIES FROM B.D.Q., INC., WITHOUT EXPRESS WRITTEN AUTHORIZATION FROM B.D.Q., INC, AND THE ENGINEER OF RECORD, WALL COLUMN SCHEDULE (ALLOW. COLUMN HEIGHTS VS. WALL PANEL WIDTH) L/80 MAX. ALLOWABLE DEFLECTION (140 H, EXP.'B', 21 P.S.F. DESIGN LOAD) DIMENSION COLUMN HEIGHT vs W L PANEL WIDTH (DESIGN PRESSURE - 21 PSF) S12E Tf I Tw 900 TV rOV 5 6' S 0' 5' 6' S 0" 4' 6' 4' 0' 2x4 L .100 .M TV 1-8- 6' 0' V 3' 8' 1' 9' 0' V V V II' ID' V 2x5 L .116 .0W 9' 0' 9' 4' 9' 8' ID' 0' 10' 5' 10' II' II' 5' 12' 0" TV 2x8 L .120 .050 9' 4' VW 1010, 10' 5' ID' 9' II' 3' II' ID' 12' 5' 13' 2' 2x7 L A20 .057 102' 10' 6' 10' il' 11'3' II' 9' 12' 3' 12' II' 13' 6' 14' 4' 2x8 L .224 .072 1 12' 6' 1 12' 11' 13' 3' 13' 9' 14' 4' 15' 0' 1 18' 10' IT 10' 21-0- 24 L L) .209 .072 15' 0' 1 15' 1' 1 16' 1' 16' 8' 11-4- 18' 2' 19' D' 20' 0' 21' 2' 2x9 L (H) .306 1 .082 L IV l' 1 19' 2' 19' II' 20 1' 21' 5' 22' 4° 23' $' 24' 8' 26' V 2x10 L .389 1 .092 22' 0' 22' 9' 23' b' 24' 4' 25' 4' 26' 5' 2T V 29' 1' 30' 9' TF GO1IFCINENT 5HAPE6 AND 5FECIFICATION6 rw, 0 O r- SELF -MATING CV) FLAT L7 2x3"H" 3x3'H' THE ACTUAL VALUES FOR 'Tr (FLANGE THICKNESS) AND 'Tw' (WEB THICKNESS) FOR THE VARIOUS SIZE SELF -MATING MATERIAL ARE INDICATED ON THE UPRIGHT HEIGHT AND BEAM SPAN TABLES. HOST STRUCTURE WIT STRUCTURAL GUTTER Iu H05T STRUCTURE WITH STRUCTURAL GUTTER MANSARD ROOF BEAM SPAN MANSARD BEAM 5PAN5 ARE BASED ON A MAXIMUM SP�ICE ANGLE OF 30° FOR HALF -MANSARD BEAM SPANS, USE VALUES 5HOWN IN 'MANSARD BEAM SPAN TABLE (SAME MAX. SPLICE ANGLE uI (30°) APPLIES TO HALF -MANSARD BEAMS) �Lu `n ¢ H05T STRUCTURE WITH STRUCTURAL GUTTER PEAK / GABLE ROOF N 1 2' 2 x 2 x .093 TUBE DIAG. BRAGING BEAM SPANS AND COLUMN SIZES ON THIS SHEET ARE BASED ON SIMULTANEOUS LOADING, AS DEFINED IN TABLE 02002.4, F.B.C. 2004, FOR 140 MPH WINDS, FOR EXPOSURE CATEGORY 'B' (21 P.S.F. WALLS, 6 P.SF. ROOF, 300LB'CONCEN. LOAD) FLAT SIMPLE ROOF BEAM SCHEDULE FMRATWAVA, Lwwx.(140mpH,Exr-os.'s•) DIMENSION ROOF PANEL WIDTH va 8EA I SPAN (FOR MAX. WALL HEIGHT OF 16' n SIB Tf Tw 8 0" 7' 8" r 0" 8' 8" 6' 0' S 6' I S 0" 4' 6" 4' 0" 2x4 L .100 .045 12' 9' 13' 3' 13' 9' 14' 4' 15' O' 15' 8' 16' 5' IT4' 2x5 L .116 .050 15' 9' 10 4' 11-0- 1T 8' IS' 4' 19' 2' 20' 2' 21' 3' 22' T 2W L 120 .050 16' 4' IT 0' IT 1' 18' 2' 19' 0' IT II' 20' 9' 22' 0' 23' 3' W L .120 .057 18' 0' 18' 5' lV 2' 19' 11' 20' 8' 21' 8' 22' 9' 24' 0' 25' 4' W L VA .072 22' 0' 22' 8' 23' 5' 24' 4' 25' 4' 26' S' 2T 8' 29' 2' 30' 9' 24 L L .209 .072 26' Y 21' 1' 1 28' 6' 2511. 30, 9' 32, V I 33' 8' . 35141 3115, 2x9 L (H) .300 .082 7B7 2" 34131 35,51 36' l' 38' 2' Be- 9' 1 41' 1' 4Y 1' 46' 2' 2x10 L .389 M 39' 2' 40' 4' 41- l' 43' 2' 44' 9' 4V 1' 48' 1' 51' 0' 53' 9' (°) REPRESENTS SPAN VALUES THAT ARE DEFLECTION -LIMITED BEAM SPAN CALCULATION NOTE:. THE SPANS IN THESE TABLES ARE BASED ON BOTH THE HOST STRUCTURE MOUNTING POINT AND WALL HEIGHT BEING THE SAME MEASUREMENT. MANSARD / CENTER PEAK (GABLE) ROOF BEAM SCHEDULE Uri au x (140 mm `THIS SPAN TABLE IS LIMI EED TO A MAX6 VERTICAL RISE OF 3' 0" (36" )' DIMENSION ROOF PANEL WIDTH vs SPAd (FOR MAX. WALL HEIGHT OF 8' W) SUE Tf Try 8'0" 7'60 r0" 6'6" VO' 5!6' 60" 4'W 4'W 2x5 L .116 1 .050 816, ID' 6' 12' 1' 1 14' 9' 2x8 L .120 .050 ID' 0' II' 10' 14' 0' IV 0' L .120 .057 813, 101 ' II' 8' 13' 4' 15' 2' IT O' IV 2' 2x8 L .224 .072 14' 0' I5' 2' 16' 4' ' 9' 1V 2' 20' l' 22' 4' 24' 3' 26' 4' 2x9 L {L) .209 .072 20 V 22' 0' 23' 2 24' 6' 26' 0' 21' 1' ?T 6' 31' 5' 33' II' 2x9 L (H) .3W .082 26' 9' 1 30' 1' 31' S' 32' II' 34' 6' 3b' 4' 38' 6' 40' 8' 43' 6' 2A0 L 35, 8' 31, 2' 38' 6' 40' 2' 42' 0' 1 44' 2' 46' 3' 1 48' II° 1 51' 8' MANSARD / CENTER PEAK (CABLE) ROOF BEAM SCHEDULE Uas Lux o4o mPH, W.'n *THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL RISE OF 3' 0' (381' DIMENSION ROOF PANEL WIDTH vs BEAK! SPAN ,(F'OR MAX. WAIL HEIGHT OF 12 01 SIZE Tf Tw 50' r8" r0' 8'6" 50' S'0" 50' 4'8" N0' 2x5 L .116 AM 2x6 L .120 .050 9' 6' 2X7 L A20 .057 11' 0' 14' 2' 2x8 L ,224 .072 8' 0' ID' 2' 12' 2' 14' Y 16' 3' 18' 4' 20' 1' 23' 2' 2x9 L (LL .209 .072 16' 2' 11' l' 19' 2' 20' Y 22' 6' 24' 5' 26' 6' 28' 9' 31' 5' 2x9 L (H) .308 .082 25' 1' 1 21'2' 1 25' 1' 1 30' 3' 1 32' 2' 34' 2' 36' 3' 38' 9' 1 41' 6' 2x10 L .38 1 .GA2 33' 3' 1 34' 9' 36' S'1 38' 2' 1 40' 1' 42' 3' 44' 1' 1 41' 2' 1 4V II' MANSARD / CENTER PERK (GABLE) ROOF BEAM SCHEDULE Lw wx. (14o MPH, Ev. v) 'THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL RISE OF 3' 0' (36')' DIMENSION ROOF PANEL WIDTH vs BEAM SPAN (FOR M. WALL HEIGHT OF 16' n SUE Tf Tw 8'0' rir r0" 08' 6W S'8' S0' 4'6' 4'0" 2x7 L .120 .037 2x8 L .224 .072 10' 0' 13' 2' 16' 3' IV 4' 24 L (L) .209 .072 9' 4' 11' 9' 14' 0' 16' 3' IS' 5' 20' 1' 23' 2' 25' 9' 28' 6' 2x9 L H) .305 482 22' 2' 23' 8' 25' 6' 21'5' 29' 5' 31' 6' 33' 11' 36' 6' 3V l' 2x10 L .389 •092 306' 3T Y 34' 0' 35' 11' 31' 11' 40' 2' 42' 8' 45' 5' 48' 8' MANSARD BEAM SPANS OF LESS THAN 8' 0' ARE OMITTED FROM THIS TABLE 3- a. D CD Cc � lux ~ LLJ � t',c tl 0�L'7SfaIn lL�Li. Lm M 10.2 �iEadw co LL �01 _ _pw in . a � ®Lu cn 5E ®P4� m UP TO 16' BEAM SPAN 1(9I TO 24' BEAM SPAN 24' TO 32' BEAM SPAN 32' TO 40' BEAM SPAN O-INDICATES WALL PANEL_ THAT SHALL HAVE DIACONAL. "K"-BRACING IN IT UP TO 8' WALL HGHT EXIST. HOST STRUCTURE EXIST. HOST STRUCTURE NUMBER OF PANELS VARIES 8' TO 12' WALL HGHT E*�31&1011111! 0 WE PA ll PAN 0 hNENNIENFIAN EXIST. HOST STRUCTURE TOTAL NO. OF BAYS VARIES THREE (3) BAYS ON EACH END OF OUTER -MOST WALL SHALL HAVE DIAG. BRACING EXIST, HOST STRUCTURE TOTAL NO. OF BAYS VARIES THREE (3) BAYS ON EACH END OF OUTER -MOST PANELS AND TWO (2) PANELS IN SECOND OUTER -MOST ROW OF PANELS SHALL HAVE THE DIAGONAL BRACING (AS SHOWN) THE BRACING SCHEMATICS SHOWN ABOVE ARE THE SAME BRACING CONFIGURATION, REGARDLESS OF ROOF TYPE (MANSARD, PEAK, DOME, FLAT, ETC.) DESIGN NOTES: ALL DIAGONAL BRACING, USED EITHER IN THE ROOF OR AS 'K'-BRACING IN THE WALLS SHALL BE 2' x 2' x .093 WALL THICKNESS TUBE, AND SHALL BE CUT TO FIT SNUG, WITH NO PLAY OR SHIFT IN THE BRACING. SEE DETAILS AT RIGHT FOR CONNECTION SPECIFICATIONS DESIGN NOTE: ALL THRU-BOLTS PASSING THROUGH ANY ALUMINUM MATL. WITH A WALL THICKNESS LE66 THAN .090, SHALL HAVE A I�/a-INCH (OUTSIDE DIA.) FENDER WASHER (SEE GENERAL NOTE *2 ON SHEET 02 REGARDING SEPARATION OF DISSIMILAR METALS). THE CONTRACTORS.MAY, IF THEY CHOOSE, INSTALL THE ANGLE CLIPS FOR THE DIAGONAL TUBE BRACING (WHERE IT ATTACHES TO THE SELF - MATING SCREEN ROOF BEAMS) WITH THE THRU-BOLTS ONLY PASSING THROUGH ONE HALF OF THE BEAM. THIS- 15_A_VRUCTURALLY ADEQUATE ALTERNATIVE, AND WILL PERMIT INSTALLATION OF THESE ANGLE CLIPS IN THEIR SHOP, DURING FABRICATION (POSSIBLY SAVING TIME DURING INSTALLATION IN THE. FIELD). N NOTE: ALL DIACONAL BRACING SHALL BE ATTACHED VIA THE 2 x 2 x 1/a" ANGLE CLIPS, AS SHOWN, AND SHALL HAVE EACH END ATTACHED TO EITHER THE SCREEN ROOF BEAM OR TO THE EVE RAIL.. NO DIACONAL BRACING SHALL_ BE ATTACHED —TO —ANY -OF THE ROOF PURL.IN6- 2 x 3 x .010 SCREEN ROOF PURLIN UPPER ANGLE CLIP TO BE PI_ACED AT SAME ANGLE AS THE MANSARD LEG OF THE SCREEN ROOF BEAM / 2x3x.010EVE RAIL 2 x 2 x 11/8'. ANGLE CLIP, CUT AT A 45' (+/-) ANGLE AND ATTACHED TO THE 2 x 3 x .010 EVE RAIL WITH ONE (1) 1/4' DIA. THRU-BOLT, WITH FENDER WASHER (SEE DESIGN NOTE ABOVE 2 x 3 x .010 SCREEN ROOF PURL IN E� j 2 x SMB SCREEN ROOF BEAM (TYP) SPLICE JOINT i--2 x 2 x pia' ANGLE CLIP, CUT AT A 4V (+/-) ANGLE AND _ ATTACHED TO THE SCREEN ROOF BEAM WITH ONE (1) 114' DIA. THRU-BOLT, WITH ® FENDER WASHER (SEE DESIGN NOTE ABOVE F[LE L;OwkY 2 x 2 x .OS3 DIAGONAL ROOF BRACE, CUT AT 45` ANGLE (+/-) AT EACH END AND ATTACHED TO EACH ANGLE CLIP WITH A 1/4' DIA. THRU-BOLT, AS SHOWN TYPICAL ANGLE ARTICULATION TO CREATE UPWARD ANGLE [) I Ac:;0NAL ROOF 5RAC I NG DETAIL O 5 wu a� co -, 0�®WL o �fo 5 03 Lu oww a i UL .jol IX E 0- ILL 0Lu 0 L: CL gpEeLg�z6 C! L4 5EA�l 5FLICE 5FECIFICATION5 8' f14 TEK SCREW (TYPICAL-)— -` -- — - o _ -1 o o 0 0; 0 o o-}- \O o 0 01 \0 0 0 ° 0 0 0 0 O 0- \o O d \ O ui z a �d SPLICE PLATE MATERIAL \ SHALL E3E 1/4' THICK (MIN.) AND 15E EITHER 16063-T6 _ OR 0606146 ALLOY IBEAM eFLICE DETAIl (2 x. S IBEAMS AND LARGER) W4 TFK SCREW (TYPICAL) 0 0 a N O \ i1 p 0 0 \ w- \\ 0 0 0 0 cn C 0 \\ 0 SPLICE PLATE MATERIAL 5HALL BE 3/16' THICK (MIN.) 12' �CSA\" AND RE EITHER 06063-T6 OR 06061-T6 ALLOY F3FAM 5PLICE DETAIL (2 sc 1 13EAM5 AND 5MALLER) TYP. ROOF SEAM TYPICAL OR 1/4' THICK SPLICE PLATE SPLICE PLATE TOLERANCE _NOS ALL SPLICE PLATES (ALUMINUM ALLOY %063-T(b or 06061-T6) SHALL 13F CUT TO ISE +0.000 / -0.0625, AS INDICATED IN THE SCHEMATIC DRAWING AT LEFT DIACONAL WALL 5RACING ("<' 5RACIN ) DETAIL 2x3x.010ROOF PURL IN �--Ix206TOP SAME AS 'A--BEL- OW,- - - - - — SCREEN FRAME JUST REVERSED 2 x 2 x .OS3 TUBE DIAGONAL BRACE 3x3x.010H CORNER UPRIGHT WE 4-INCH x 4-INCH x .016 PLATE, WITH (4) 012 TEKS IN THE 3 x 3,(3) 012 TEK5 IN THE BOTTOM I x 2 AND (3) 012 TEK IN THE 2 x 2 BRACI 3 x 3 COLUMN 2x2x.093T1 DIAGONAL 51' I x 2 BOTTOM SCREEN FRAM 2 x 3 x.010 CHAIR RAIL 2 x 2 x .093 TUBE - DIA6ONAL BRACE DETAIL "Au (OUT5IDE) 2 x OMB SCREEN ROOF BEAM 2 x 51115 UPRIG' " 2 x 2 x ,OS3 TUBE - DIAGONAL BRACE 2x3x.010 I x 2 05 BOTTOM CHAIR RAIL SCREEN FRAME (IN51D�)_ - 13 'H- (:UKNt7-N )LUMN 2 x 2 x .093 TUBE DIAGONAL BRACE I x 2 50TTOM SCREEN FRAME I -INCH x 3-INCH x .093 ANGLE, CUT 4- INCHES LONG, WITH (3) 012 TEK5 IN THE 3 x 3,(3) 12 TEKS IN THE BOTTOM I x 2 AND (3) 012 TEK5 IN THE 2 x 2 5RACF 2 x 2 x .093 TU15E - DIAGONAL BRACE 2 x 5 SMB UPRIGHT (MINIMUM SIZE) 2 x 2 x .093 TUBE - DIA6ONAL BRACE 2 x 5 5M5 UPRIGHT (MINIMUM SIZE) 2 x 3 x .010 CHAIR RAIL 2 x 2 x .093 TUBE - PIAGONAL BRACE DETAIL '5' 0 0 0 0 ° 0 0 0 00 0 0 0 0 0 0 (OUT5IDE) d 0 0 0 0 0 (IN51DE) 14 Ld d ui en c� `L e € � I �� 4-INCHx' 10-INCH x .010 PLATE, WITH (1) 412 TEKS IN THE SMB F UPRIGHT, (3) 012 TEKS Q Uj L IN THE CHAIR RAIL AND (3) 12 TEKS IN EACH 2 x 2 BRACE 2x3x.010 93 oILL CHAIR RAIL -1 ®sue a zIX WMa-� �Lu W 0 NCH x 3-INCH x ANGLE, CUT 4- INC 1-1 .0 IN (3 SM (3) 012 TEKS IN THE 2 x 2 BRACE --2x3x.010 CHAIR RAIL I -INCH x 3-INCH x .093 ANGLE, CUT 4- INCHES LONG, WITH (3) 012 TEK5 IN THE 5MB UPRIGHT AND (3) 012 TEK5 IN THE 2 x 2 BRACE �3CREEN ROOF ENCL05URE-TO-b05T SiR'UCl'URF= ATTACHMENT [DETAIL �� �1 ��45GIA REINFORCEMENT DE51CsN NOTE, FILE COPY DESIGN NOTE: THE 3-INCH LEG OF THE ANGLE SHALL BE PLACED AGAINST THE I x 2.- THIS ALLOWS A MIN. EDGE DISTANCE FOR THE FASTENERS (FROM THE EDGE OF THE ANGLE) OF ONE -INCH, AND MAINTAINS A SIX-INCH MIN. CENTER -TO -CENTER D15TANCE FOR THE MAX. SIZED CONCRETE ANCHORS (3/8" x 31/2') w-vnrn n��..ti CAP (TYP) HOST C.B.S. WALL (TYP) TYP SCREEN ROOF BEAM I x 2 2'X3'x.125'ANGLE W/(4)$12 TEKS, TYP. EACH SIDE OF BEAM ALL FASCIA BOARDS ON ANY EXISTING HOST STRUCTURE THAT WILL HAVE ANY PART OF THE PROPOSED SCREEN ENCLOSURE ATTACHEID TO IT SHALL -BE-REINFORCED, BY PLACING ONE (1) 1/4' x 4' LAG-SCREW-INT®.THE-END-OF-- EVERY TRUSS TAIL (WHERE THE PROPOSED SCREEN ENCLOSURE 15 BEING INSTALLED). THESE TRUSS TAILS MUST BE PILOT DRILLED WITH A 5/32" DRILL BIT TO PREVENT SPLITTING THE END OF THE TRU65 TAILS. IT SHALL BE THE; REP50N5181LITY OF THE INSTALLING CONTRACTOR TO ENSURE` THAT THIS STEP 15 COMPLETED, AS SPECIFIED, PRIOR TO ANY INSTALLATION TAKING PLACE. FASTENER SHALL BE 1/4' x 3 1/2' RED -HEAD ITW TAPCON FOR ALL 2' x 6' BEAMS AND SMALLER, FASTENERS SHALL BE 3/8' DIA. FOR 2' x I' BEAMS AND LARGER (SEE DESIGN NOTE ABOVE REGARDING 3/8 FASTENER SPACING) WALL ATTAGNMENT FA5GIA REINFORCEMENT 5PEGIFICATION5 1/4' x 4' LAG SCREW, TO IBE INSTALLED INTO THE END OF EVERY TRUSS TAIL WHERE A SCREEN ENCLOSURE .WILL BE ATTACHED. THE TRUSS TAIL SHALL BE PILOT- DRILLE:D WITH A 5/32' DRILL 51T (TO PREVIEW SPLITTING THE END OF THE TRUSS TAIL) IXUbS IAIL (ITI-) 2 x FASCIA BOARD (TYP) U-vFiHIVIVGG- CAP (TYP) NOTE: FASCIA ATTACHMENT REQUIRES A 2 x FASCIA BOARD -(MINIMUM). A 'I-x-' FASGI,JS_ ONt Y AREQUATI= _ FOR THIS INSTALLATION WHEN THERE 15 A 2 x SUB- Y FASCIA BEHIND IT. IN THIS CASE, THE LAGS MUST PENETRATE THE SUB -FASCIA II/2' (MIN. EMBEDMENT). IT SHALL BE THE RESPONSIBILITY OF THE SCREEN CONTRACTOR TO VERIFY THE PRESENCE OF THIS SUB-FA5CIA, TYP 5CRFEN ROOF BEAM I x 2 2' X 2' X .125' ANGLE W/ (4) 012 TEK5, TYP. EACH SIDE OF BEAM 1/4' x 21/2' LAG SCREW TYP. I EACH SIDE OF BEAM (2' x 6' BEAMS AND SMALLER) 3/6' x 2 1/2' LAG SCREW (2' x 7' BEAMS AND LARGER) — FASCIA ATTAl.m1"'tI IENT 10-INCH LONG 025 THICK) EXTRUDED SEE "SNAP / LAP CONNECTION' 10-INCH LONG 025 THICK) EXTRUDED 'z' GUTTER INSERT, TYP CENTERED ON NOTE ON SHEET I FOR 5PEC.'S 'V GUTTER INSERT, TYP CENTERED ON SEE 'SNAP / LAP CONNECTION' EACH ROOF BEAM, WITH FOUR (4) 010 EACH ROOF BEAM, WITH FOUR (4) #10 NOTE ON SHEET I FOR SPEC.'S TEK5 THRU TOP LIP OK GUTTER TEK5 THRU TOP LIP OF GUTTER 2 x HOUSE FASCIA �Q 2 x 3 x .125 ANGLE CLIP (5EE FASCIA NOTE TYP. 2 x SCREEN ROOF (CUT 2' LONG) W/ 3-INCH ABOVE) BEAM (MAY BE FLAT 1/4' X 21/4' LAG5, FOUR (4) LEG AGAINST i x 2. CLIP OR SLOPED) IN EACH 10-INCH INSERT �" ° SHALL HAVE FOUR (4) 012 1/4' x 21/4' LAGS, FOUR (4) IN EACH 10-INCH INSERT ° a 2 x 3 x .125 ANGLE CLIP AND AT 24' O.C. (MAX. SPACING) IN THE REST N o TEK5 INTO SIDE OF ROOF BEAM AND TWO l2) 14 x AND AT 24" O.C. (MAX. a a (CUT 2' LONG) W/ 3-INCH OF THE GUTTER (PILOT 2' TEKS (PER ANGLE CLIP) SPACING) IN THE REST I LEG AGAINST I x 2. CLIP DRILL FASCIA W/ 5/32 N THRU GUTTER AND INTO 7' OF THE GUTTER !PILOT o SHALL HAVE FOUR (4) 012 BIT TO AVOID SPLITTING) ° GUTTER INSERT (TYP. ONE DRILL FASCIA W/ 5/32' ° TEKS INTO SIDE OF ROOF N ANGLE CLIP ON EACH SIDE BIT TO AVOID SPLITTING) BEAM AND TWO (2) 014 x ° OF EACH BEAM) I U-CHANNEL I x 2 x .0S3 ANGLE SPACER CAP (TYP) 2' EKS (PER ANGLE CLIP) RU GUTTER AND INTO 'z' TYP. 2 x SCREEN ROOF (FOR ANGLED FASCIA BD, I x 2 SCREEN GUTTER INSERT (TYP. ONE �.p - BEAM (MAY BE FLAT ATTACHMENT), ATTACHED FRAME (TYP) ANGLE CLIP ON EACH SIDE OR SLOPED) 5' STRUCTURAL W/ TWO (2) ROWS OF 010 TEKS OF EACH BEAM) 5' STRUCTURAL I x 2 SCREEN (STAGGERED), EACH ROW AT GUTTER (CONT.) GUTTER (CONT.) FRAME (TYP) 18' O.C. (MAX, SPACING) PLAN VEW - SECTION VIEW 5TUCTUALo GUTTER CONNECTION DETAIL - - ---- �Rm Im �Lu 12 y�� o c ��� L8 R�fn �0 im 0 H §1 ZFaF0 0 LUZiLLL t� Lu - 0 r. LU FRONT WALL 2 x 2 x 3/16' ANGLE, WITH FOUR (4)112 TEKS INTO THE UPRIGHT I x 2 OB BOTTOM FRAME AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR 2 3/4', MIN. EDGE (MIN. OF 4-INCH EMBEDMENT Q INTO THE CONCRETE) DISTANCE 3 x 3 x .010 FRONT WALL SIDE WALL CORNER UPRIGHT 110 x 2' SMS SCREW, WITH $/8' DIA. WASHER (SEE GENERAL I x 2 OB BOTTOM FRAME w NOTE 03, SHEET �2) TO BE IS- Lu !ac' INCHES, CENTER -TO -CENTER I x 3 OB SIDE -WALL CORNER MAX, SPACING UPRIGHT �� ; PLAN VIEW MANSARD SCREEN ROOF 2 x 3 x 010 EVE RAIL, EiEAM (BEYOND) TYP. (CONTINUOUS) 2 x 5 x '/a' ANGLE (2-INCHES LONG) WITH (2) 014 TEKS INTO TOP OF 2 x 3 EVE RAIL AND (2) 014 TEKS, INTO THE FRONT I x 2 OB TOP FRAME OF THE 3 x 3 H FRONT WALL CORNER UPRIGHT I x 3 OB SIDE -WALL CORNER UPRIGHT 010 x 2' 5M5 SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE'3, SHEET 02) TO BE 18- INCHES, CENTER -TO -CENTER 3 x 3 x ,010 FRONT WALL MAX. SPACING CORNER UPRIGHT •2 x 2 x 3/16' ANGLE, WITH FOUR (4) N2 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR 2 ,MIN, EpGE (MIN, OF 4-INCH EMBEDMENT pISTAN' E INTO THE CONCRETE) 0 0 I x 2 OB BOTTOM FRAME ELEVATION VIEW CORNER UPRIGHT DETAIL NOTE: THIS ATTACHMENT DETAIL ALSO APPLIES TO A 2 x 2 SCREEN FRAME, W/ THE FASTENER BEING 4' IN LENGTH, TO MAINTAIN A 2' MIN. EMBED, IIAIZ BE 2' INTO CONCI E. I x 2 D,B. SCREEN FRAME, TYP. BETWEEN UPRIGHTS OR AS UPRIGHTS AGAINST A WALL. OR COLUMN I/4' DIA, x 31/4' TAPCON TO BE PLACED AT NO MORE ,THAN 18' O.G. IRE: GEN. NOTE '3) CONC. / C.B.S. / MASONRY SURFACE NOTE: ALL FASTENERS SPECIFIED IN 'COIUM-TO-FOUNDATION' DETAILS PERTAIN ONLY TO THE FASTENERS TO IBE PLACED ON EITHER SIDE OF COLUMNS. THIS DETAIL IS FOR ALL INTERMEDIATE FASTENERS FOR I x 2 SCREEN FRAME TO EITHER CONC. DECK OR C.S.S. MASONRY WALL. 2 x 3 x .010 ROOF PURLIN 2 x 3 x .010 EVE RAIL, TYP. (CONTINUOUS) 2 x 5 x 'ia' ANGLE (2-INCHES LONG) WITH (2) 014 TEKS INTO TOP OF 2 x 3 EVE RAIL AND (2)114 TEKS INTO THE FRONT OF THE 2 x SMB SIDE WALL UPRIGHT I x 2 OB TOP FRAME 010 x 2' 6M6 SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE *3, SHEET 02) TO BE 18- INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 5 SMB UPRIGHT (MINIMUM SIZE FOR ANY UPRIGHT ON A SCREEN ROOF ENCLOSURE) 23/4' MIN. EDGE DISTANCE SEE 'MINIMUM FOOTER TABLES' ON SHEET PI 0 0 0 21ie' x I1%' U-CHANNEL CLIP ATTACHED TO THE EVE RAIL WITH SIX (6) a12 TEKS, AND (3) 012 TEKS INTO EACH SIDE OF THE 2 x 3 ROOF PURLIN (T0 BE ATTACHED ON THE TOP END TO THE SCREEN ROOF BEAM IN THE SAME MANNER 2 x 4 x''/a' ANGLE (2-INCHES LONG) WITH (2)014 TEKS INTO BOTTOM OF THE 2 x 3 PURLIN AND (2) 114 TEKS INTO THE BACK OF THE 2 x 61115 SIDE WALL UPRIGHT 2 x 3 x ,010 CHAIR RAIL (TYP) 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE el) 3/8' REP -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) I x 2 OB BOTTOM FRAME BEAM_61ZE 2x5-2x(o 2x1-2xa 2x9 2x10 2 x SMB SCREEN ROOF BEAM 2 x 3 x .010 ROOF PURLIN NO. OF #14 TEKS (PER 61DE) (2) 014 TEKS (4) #14 TI_K5 (5) 014 TEK5 l6) 014 TEK5 2 x 5 x pia' ANGLE (2-INCHE5 O o l LONG) WITH (2) 014 TEKS INTO C 0 TOP OF 2 x 6MB BEAM AND (2) 014 TEKS INTO THE FRONT 0 0 1 OF THE 2 x SMB FRONT WALL UPRIGHT I x 2 0B TOP FRAME. 010 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE 103, SHEET #2) TO BE 18- INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 5 SMR UPRIGHT (MINIMUM SIZE FOR ANY UPRIGHT ON A SCREEN ROOF ENCLOSURE) 23i4' MIN. EDGE DISTANCE I x 2 05 BOTTOM FRAME — SEE 'MINIMUM FOOTER TABLES' ON SHEET 11 33i' 3" MIN. MIN. v. SCREEN ROOF BEAM SHALL OVERLAP ON THE OUTER SIDE OF BOTH SIDES OT THE UPRIGHT (TYP. EACH BEAM -TO -UPRIGHT CONNECTION) SEE TABLE ABOVE FOR NUMBER OF 014 TEKS, AS SPECIFIED BASED ON BEAM SIZE 2 x 3 x .010 CHAIR RAIL (TYP) 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) 5IpE WALL UPRIGHT DETAIL FRONT WALL UPRIGHT [DETAIL �j uoU. o � ®E— (35 t W 00 00 a.U. owo 0�. T ' CARRIER BEANS APPLICATIONS FOR SOLID ROOF / SCREEN ROOF COMBINATION JOBS (BASED ON 8' 01' COLUMN SPACING) TRIBUTARY AREA CONTRIBUTING SCREEN ROOF LOAD WIDTH (TRIBUTARY AREA) (SEE SCHEMATIC LAYOUT FOR DESCRIPTION) FOR SOLID ROOF 50' 60" T0" 8'0' 90" 1TY0' 11,0' 120' 13,0" 14'0° 15,0" 16,0' 1TO" 18'0' 19'0' 20'0' 4'0' +2x5(A) +2x5(B) +2x5(6) +2x5(5) +2x5(13) +2x6(5) +2x6(B) +2x1(5) +2x1(6) +2x1(C) +2x1(C) '2x8(C) +2x8(C) +2x8(C) +2x8(C) 2x8(0) 5'0°• +2x5(5) +2x5(B) +2x6(6) +2x6(5) +2x1(B) +2x1(6) #2x1(5) +2x1(C) +2x8(C) +2x8(C) +2x8(C) +2x8(C) 2x8(C) 2x8(D) 2x8(D) 2x8(D) 6'0' +2x6(a) +2x1(B) +2x11B) +2x1(5) +2x1(C) •2x81C) p2x8(C) +2x8(C) +2x8(C) +2x8(G) 2x81p) 2x8(D) 2x8(D) 2x8(D) 2x6(0) 2x8(p) TO' +2x1(5) +2x1(5) +2x8(C) +2x81C) +2x8(C) +2x8(C) +2x8(C) 2x8(C) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 8'0' +2x8(C) +2x1(C) +2x8(C) +2x8(C) +2x8(C) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x6(D) 2x8(D) 2x9-L(D) 2x9-L(D) 2x9-L(D) V 0' + 2 x 8 (C) + 2 x 8 X) + 2 x 8 (C) 2 x 6 (D) 2 x 8 (D) 2 x 6 (D) 2 x 8 (D) 2 x 8 (D) 2 x 8 (D) 2 x 6 (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 10' 0' 2 x 8 (C) 2 x 8 (D) 2 x 8 (D) 2 x 8 (D) 2 x 8 (D) 2 x 8 (D) 2 x 8 (D) 2 x 9-L (D) 2 x 9-L (0) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (E) 2 x 9-L (E) TRIBUTARYAREA CONTRIBUTING SCREEN ROOF LOAD WIDTH (TRIBUTARY AREA) (SEE SCHEMATIC LAYOUT FOR DESCRIPTION) FOR SOLID ROOF 5'0" 900 710" 8'Og 9'0" 10'0° 1110° 120' 13,w 14'O" 1&0" 16'0" 1 1TO- 18'0' 19'0° 20'0' N 0' + 2 x 1 (5) + 2 x 8 (5) + 2 x 8 (6) + 2 x 8 (B) + 2 x 8 (5) + 2 x 8 (C) + 2 x 8 (C) + 2 x 8 (C) + 2 x 8 (C) 2 x 8 (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 5' 0" + 2 x 8 (5) + 2 x 8 (6) + 2 x 8 (C) + 2 x 8 (C) 12 x 8 (C) + 2 x 8 (C) 2 x 8 (C) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (p) 2 x 9-L (D) 2 x 9-L (D) 6'0' + 2 x 8 (C) + 2 x 6 X) + 2 x 8 (C) + 2 x 8 X) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L 1pl 2 x.9-L (D) 2 x 9-L (D) 2 x 9-1- (D) 2 x 9-L (0) 2 x 9-H (D) 2 x 9-H lD) T 0' + 2 x 8 (C) + 2 x 9-L (C 2 x 9-L (0) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (p) 2 x 9-L (p) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-H (D) 2 x 9-H (2) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 8' 0' 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-14, (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (E) 2 x 9-14 (E) 2 x 9-H (E) 910° 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-1- (D) 2 x 9-L (D) 2 x 9-H (D) 2'x 9-H (0) 2 x 9-14 (D) .2,x 9-H (D) 2. x 9-H (D) 2 x 9-H (p) 2 x 9-.H (E) 2 x 9-H M) 2 x 9-H (E) 2 x 9-14 (F) 2 x 9-H (F) 10'0- 2 x 9-L (D) 2 x 9-L (D) 2 x 9 H (D) 2 x 94'(D) 2 x 9-14 (D) 2 x:9-H (EJ 2 x'9=H (E) 2 x 9-H (E) 2 x 9-4 (E)' 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (F) 2 x 9-H (F) 2 x 9-H (F) 2 x 9-H (F) CARRIER BEAM APPLICATIONS FOR SOLID ROOF1SCREEN ROOF, COMBINATION JOBS (BASED ON 12' .011 COLUMN SPACING) TRIBUTARY AREA CONTi ROUTING SCREEN ROOF.LOAD WIDTH (M3UTARY AREA) (SEE SCHEMATIC LAYOUT FOR DESCRIPTION) FOR SOLID ROOF 5'0' 6'0- TO' 8109 9'0' , 1.'4° 11'0" 12'0" i3'0" 14'0'. 15'0" 16'0' 1TO" 1&0° i9'o" 4'0" 41011 + 2 x 8 (B) + 2 x 8 (C) + 2 x 9-L (C + 2 x 9-L (C + 2 x 9=L (C) 2 9-L (D) 2 x 9-L (0) 2 x 9-1- (D) 2 x 9-L (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x'9-H (D) 2 x 9-H (E) 2 x 9-H (E) 5'0- + 2 x 9-L X+ 2 x 9-L (C + 2 x 9-L*(C 2 x 9-L (D) 2 x 9-L (p) x 9rl 1p1 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9=H lE) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 6'0° + 2 x 9-L lC 2 x 9-L (D) 2 x 9-L (D) 2 x 9-H (0) 2 x 9-H (p 2 x 9-H (D) 2 x 9-H (D) 2'x 9 - H, (D) 2 x 9-14 (D) 2 x 97H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-14 (E) 2 x 9-H (F) T O' 2 x 944 (D) 2 x 9-H (D) 2 x 9-14 (D) 2 x 9=H (0) 2 x 9-14 (q) 2--x '91W(D) 2 k 9>H (0) -2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9=H (E) 2 x 9-H (E) 2 x 9-H (F) 2 x 9-H (F) 2 x 9-H (F) 2 x Im (F) 8' 0" 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) .2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (F) 2 x 9-H (E) 2 x 9-H (F) 2 x 9-H (F) 2 x Im (F) 2 x Im (F) 2 x Im 0 2 x 10 (P) H H M) H (E) 2 H (E) 2 H (E) 2'1H (E) 2 I (F) z Im (F) 2 Im (F) I (F) GENERAL NOTES - I. THIS SET OF DETAIL SHEETS MUST BE ACCOMPANIED BY FULL SEALED SETS OF BOTH 'POOL / PATIO ENCLOSURE WITH SCREEN ROOF' AND 'ALUMINUM ROOF (PAN OR INSULATED) SCREEN ROOM ENCLOSURE' ENGINEERING DETAIL SHEETS TO BE VALID FOR —PERMITTING PURPOSES. -- 2. IF PROPOSED •JOB'S COLUMN SPACING EXCEEDS THE SPACING INDICATED ON ONE OF THE TABLES (AT LEFT) THE NEXT LARGER SPACING SPECIFICATIONS SHALL GOVERN WITH REGARDS TO THE CARRIER BEAM AND FOOTER SIZES. 3. IF JOB CONDITIONS EXCEED THE LARGEST COLUMN SPACING INDICATED ON THE TABLES AT LEFT (12' 0' CENTER - TO -CENTER), THE COLUMN SPACING MUST BE REVISED TO FALL WITHIN THESE PARAMETERS, OR THE JOB MUST BE REDIRECTED BACK TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC DESIGN 4. ,ANY CONDITIONS THAT EXCEED ANY OF -THE DESIGN PARAMETERS „INDICATED ON THIS DESIGN=DETAIL SHEET, THE JOB MUST BE REDIRECTED' BACK TO THE NGIN OF REC ORD O IT - EER RE RD FOR S E SPECIFIC DESIGN. 5. REFER, TO GENERAL NOTES AND ALL OTHER-DE51GN NOTES ON BOTH THE >w SCREEN ROOF AND ALUMINUM ROOF ENGINEERING DETAIL SHEETS, AS THEY ALL SHALL STILL GOVERN ANY AND ALL FABRICATION AND INSTALLATION OF THESE. ENCLOSURES. 6. THE TRIBUTARY AREAS INDICATED ON THESE TABLES (AT LEFT) ARE DEFINED 2 x 9 H (D) 2 x 9-H (E) 2 x 9 H (E) 2 x 9 (E) 2 x 9- 2 x 9 x 9- x 9 x x m x x 2 x m 2 x Im (F) 2 x Im (F) 2 x Im lF) HALF OF THE SPAN OF THE SCREEN ROOF 10'0° 2 x 9 H (E) 2 x 9 H CE) 2 x 9 H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9 H (F) 2 x 9-H (F) 2 x Im (F) 2 x 10 (F) 2 x Im (F) 2 x Im (F) 2 x Im (F) 2 X Im (F) 2 x Im (F) 2 x Im (FI 2 x Im (F) REAMS AND THE ALUMINUM ROOF PANELS. T�3�E NOTES: IF SPANS ON A SINGLE JOB VARY, THE CARRIER BEAM / FOOTER PAD MUST BE I. ALL BEAMS INDICATED WITHIN THESE TABLES ARE SELF -MATING REAMS (NO TUBULAR SHAPES SHALL BE USED). Awm= USED THAT IS BASED ON THE WORST- 2. THE LETTERS IN PARENTHESIS CORRESPOND TO LETTER SYMBOLS SHOWN IN THE 'FOOTER PAD KEY' TABLE, ON SHEET #3 OF THE 'ALUMINUM ROOF SCREEN IN CASE SCENARIO FOR BOTH CONDITIONS, ROOM ENCLOSURE' ENGINEERING SHEET (WHICH ORIGINAL SEALED COPIES MUST ACCOMPANY THIS ENGINEERING DETAIL SHEET), AND REPRESENT THE WAI AND THAT APPLICATION SHALL BE USED REQUIRED FOOTER PAD SIZES NEEDED TO RESIST THE IMPOSED UPLIFT LOADS GENERATED BY EACH DIMENSIONAL REPRESENTATION. THROUGHOUT THE ENTIRE JOB. 3 THE APPLICATIONS THAT ARE MARKI=D WITH AN ASTERISK (F) ARE COLUMN SCENARIOS THAT MAY RE MOUNTEb DIRECTLY ON EXfSTING FOUR-fNCH THICK CONCRETE DECK UTILIZING 'ANCHOR DETAIL 01 (45 SHOWN ON SHEET #6 OF THE 'ALUMINUM ROOF SCREEN ENCLOSURE" ENGINEERING SF�EET ALL OF THE FOLLOWING CONDITIONS MUST BE MET FOR THIS APPLICATION TO BE STRUCTURALLY ADEQUATE. IF ANY OF THE CONDITIONS ARE NOT OR CAN'T BE MET, THEN THE CONTRACTOR MUST INSTALL THE SPECIFIED FOOTER_PAD, AS INDICATED WITHIN THE TABLES ABOVE. - A. THERE MUST BE AT LEAST THREE AND A HALF (3' 6') OF CONTINUOUS, UNBROKEN CONCRETE IN ALL FOUR DIRECTIONS FROM THE SASE OF THE PROP05ED COLUMN BASE LOCATION (49 SQUARE FEET). B. THIS CONCRETE MUST BE FREE FROM ANY CRACKS, STRESS -RELIEF CUTS, DECO -DRAINS, ETC. WITHIN THIS 49 SQUARE FOOT AREA. C. THERE MUST BE EVIDENCE VIA PREVIOUS OR CURRENT PERMIT AND INSPECTION RECORDS INDICATING THAT THIS CONCRETE WAS POURED WITH EITHER NOTE- THIS DESIGN ENGINEERING SHEET IS SPECIFIED FOR EXP. CAT. 'C" (NON-HVHZ), BUT -SHALL AL50 BE UTILIZED FOR ANY INSTALLATIONS IN AN EXP. CAT. 15' BUILDING AREA. 6" x 6% 10/10 W.W. MESH OR "FIBERMESH' REINFORCEMENT. THIS 15 THE.ONLY WAY TH15 CAN RE.VFRIFIED TO THE LEVEL OF CERTAINTY REQUIRED FOR THE ENGINEER OF RECORD TO CERTIFY THAT THIS INSTALLATION 15 STRUCTURALLY ADEQUATE TO RESIST THE IMPOSED LOADS. 4. IF ANY JOB SITE CONDITIONS EXCEED ANY DESIGN PARAMETERS ON THIS -DETAIL SHEET, THE JOB .SHALL BE DIRECTED BACK TO THE ENGINEER OF RECORD,FOR SITE -SPECIFIC DESIGN._ h w I I_ odIL -..� REM LL. 0. ®O � ® LuU. w �>,�. �>;toc Ix ®6o Qcaan2x9 1= t C Lu o�-� O CL w J n uL)Q0 a-•ozgp :�o Z a: 'nolb K -B Ld o���t �T� CDC WO ¢t2w a THE 3/16' PLATE SPECIFIED ON THE, ALUMINUM ROOF ENGINEERING SHEET (FOR 'COLUMN WITH OFFSET NOTCH' DETAIL) SHALL BE CUT TO FIT UP TO THE BOTTOM OG THE STRUCTURAL GUTTER, AND WILL ONLY HAVE ONE (1) THRU BOLT OF THE BOLTS THAT ARE SPECIFIED FOR EACH GIVEN CONNECTION PASSING THROUGH THE PLATE. THI5 PLATE SHALL STILL HAVE FOUR (4) 014 TEKS INTO THE SUPPORT COLUMN (AS ORIGINALLY SPECIFIED ON THE ALUMINUM ROOF ENGINEERING SHEET DETAIL) THREE-50LT CONNECTION THE 3/16' PLATE SPECIFIED ON THE ALUMINUM ROOF ENGINEERING SHEET (FOR 'COLUMN WITH OFFSET NOTCH' DETAIL) SHALL BE CUT TO FIT UP TO THE BOTTOM OG THE STRUCTURAL GUTTER, AND WILL ONLY HAVE ONE (U THRU BOLT OF THE BOLTS THAT ARE SPECIFIED FOR EACH GIVEN CONNECTION PASSING THROUGH THE PLATE. THIS PLATE SHALL STILL HAVE FOUR (4) 414 TEKS INTO THE SUPPORT COLUMN (AS ORIGINALLY SPECIFIED ON THE ALUMINUM ROOF ENGINEERING SHEET DETAIL) TW0=50LT CONNECTION ALUMINUM ROOF (EITHER 3-INCH RISER PANS OR INSULATED ROOF SYSTEMS) FOR ALUMINUM ROOF -TO -CARRIER - BEAM CONNECTION, CONTRACTOR MUST ONLY USE THE 2 x 2 ANCst_E WITH THRU-BOLT CONNECTION (SEE ALUMINUM ROOF ENGINEERING SHEET FOR COMPLETE SPECIFICATIONS). THE ONLY EXCEPTION WILL BE THAT THE 2 x 2 ANGLE WILL NOT BE CONT., AS IT WILL BE INSTALLED IN "CONT. SECTIONS BETWEEN THE SUPPORT COLUMNS 3 x 3 OR 4 x 4 SUPPORT COLUMN - (BEYOND) SEE ALUMINUM ROOF ENGINEERING SHEET FOR COLUMN - TO -CARRIER BEAM CONNECTION 5PECIFICATION5 2 x CARRIER BEAM, SIZED FROM CARRIER REAM TABLES ON SHT. I OF THESE ENGINEERING, DETAIL SHEETS SEE ALUMINUM ROOF ENGINEERING - SHEET FOR -SPECIFICATIONS ON THE CARRIER BEAM STITCH SCREWS 5'. STRUCTURAL GUTTER (CONT.) ATTACHED - TO CARRIER BEAM WITH 94 TEKS AT 18' O.C. MAX. 5FACING (IN ADDITION TO THRU BOLTS AT EACH 'Z'. GUTTER INSERT) EACH 10-INCH LONG 'Z' GUTTER INSERT SHALL HAVE THREE (3) 1/4' DIA THRU BOLTS, THAT SHALL PASS THROUGH THE CARRIER BEAM AND THE 2 x 2 ANGLE ON THE BACK SIDE (NOTE THAT SUPPORT COLUMNS SHALL NOT BE LOCATED AT THE SAME POINT ON THE CARRIER BEAM AS THE SCREEN ROOF BEAM51, AS THE 2 x 2 ANGLE ON THE BACK OF THE CARRIER BEAM MUST-ALSO__BACK, THE_Z!_GUTTER INSERTS) I SEE POOL / PATIO SCREEN ROOF ENGINEERING SHEET FOR COMPLETE SPECIFICATIONS FOR SCREEN ROOF BEAM -TO -STRUCTURAL GUTTER CONNECTION UTILIZING: 10-INCH LONG 'Z' GUTTER INSERT �® 00 SCREEN ROOF BEAM, AS SIZED FROM SCREEN ROOF ENGINEERING ® SHEET (FLAT OR PITCHED) FOR THIS CONNECTION, THE CONTRACTOR SHALL ADD A 2 x 2 x .125 ANGLE, BENEATH THE I X 2 SCREEN FRAME WITH FOUR (4) 012 TEKS INTO f AE SIDE OF THE SCREEN ROOF BE AND ONE (U 3/8' DIA. THRU BOLT, PLACED THROUGH A 3/4' ALUM. PICKET FERRULE (INSIDE THE GUTTER) AND THI5 THRU BOLT SHALL HAVE A FENDER WASHER ON THE BACK 51DE WITH THE NOT, TYP. ONE ANGLE AN[ -THRU BOLT ON EACH SIDE OF EACH SCREEN ROOF BEAM. ,ALUMINUM ROOF TO 50REEN ROOF CONNECTION DETAIL DESIGN NOTE: WITH REGARDS TO THE COLUMN -TO -CARRIER BEAM CONNECTION (AS INDICATED ON THE 'FOOTER PAD KEY' TABLE. ON THE ALUMINUM ROOF ENGINEERING SHEET), WHERE THE SPECIFIED CONNECTION IS MADE WITH TWO (2) THRU-BOLTS, ONE BOLT SHALL BE PLACED THROUGH THE BACK SIDE OF THE GUTTER. WHERE THE SPECIFIED CONNECTION 15 MADE- WITH THREE (3) THRU-BOLTS, TWO OF THE THREE BOLTS SHALL BE PLACED THROUGH THE BACK SIDE OF THE GUTTER (SEE DETAILS AT LEFT). w CJ0S200 o m o z b � F=R<v _0 GENERAL NOTE5 ANC [DE51GN PARAMETER51 I. THIS OVERALL DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTER 16 AND CHAPTER 20, 2006 AMENDMENTS TO FLA. BLDG. CODE 2004, AND IS BASED ON THE FOLLOWING PARAMETERS: A. WIND SPEED: 140 M.P.N., 3-SECOND GUST 5. EXPOSURE CATEGORY: '5' C. DESIGN LOADS: LIVE LOAD ID 30 P.5F, UPLIFT LOAD 6 24 P.SF., SCREEN WALL DESIGN LOAD g 21 P.S.F. D. MAXIMUM HEIGHT: 30' 0' FOR EXPOSURE CATEGORY 'B' AND 15' 0' FOR EXPOSURE CATEGORY 'C'. E. ALLOWABLE DEFLECTION: 'L' / 120 (AS SPECIFIED IN TABLE 01610.1, FOR NON -HIGH VELOCITY HURRICANE ZONES) F. CONTINUOUS LOAD PATH IS PROVIDED 2. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD) A. AL.L EXTRUSIONS: ALUMINUM ALLOY %063-T6 (NOTE: SPLICE PLATE MATERAAL- AY 6E EXTRUDED FROM ALUMINUM ALLOY % 061-T6, IF THIS ALLOY IS MORE READILY AVAILABLE TO THE CONTRACTOR). B. FASTENERS: ALUMINUM ALLOYS *102444 .4 "1015-T6, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL, OR 300-SERIE6. STAINLESS STEEL. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE FOR.SEPARATION OF 01551MILAR MATERIALS AS THEY ARE DEFINED 1N 5ECTIO.N 02003.8.4. HE / SHE MAY IMPLEMENT ANY OF THE MEANS LISTED IN THESE SECTIONS. ANY ALTERNATE MEANS MUST BE REVIEWED ANp APPROVED IN WRITING, BY THE ENGINEER OF RECORD, PRIOR TO ANY INSTALLATIONS UTILIZING THE SUBJECT METHOD. C. ROOF PANELS: SEE ROOF PANELS SPECIFICATION ON'THE ROOF PANEL SPAN TABLE. D. SCREEN CLOTH: SHALL BE VINYL -COATED WOVEN FIBERGLASS, MAX. DENSITY. 18 x 14 MESH (589- OPEN, MINIMUM). 3. ALL FASTENERS THAT PASS THROUGH ANY EXTRUSION INTO CONCRETE; MASONRY, WOOD, OR OTHER ALUMINUM EXTRUDED FRAME MEMBER, MUST HAVE A 5/8-[NCH DIAMETER WASHER (MINIMUM), AND BE NO MORE THAN 24 INCHES •CENTER- TO- CENTER SPACING (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD). 4. ALL FASTENERS ADJACENT TO COLUMNS THAT DO NOT REQUIRE REINFORCING ANGLE CLIPS, MUST BE PLACED WITHIN 4 INCHES OF THE UPRIGHT (ON BOTH 51DEW. (REFER TO GENERAL NOTE 03 FOR SPACING SPECIFICATIONS) 5. ANY CARPORT OR SCREEN ROOM THAT HAS ANY SITE -SPECIFIC DESIGN ELEMENTS THAT DO NOT COMPLETELY •CORRESPOND WITH, OR IN ANY WAY EXCEED THE DESIGN SPECIFICATIONS INDICATED ON THIS DESIGN DOCUMENT SHALL BE RE -DIRECTED BACK TO THE ENGINEER OF RECORD FOR CERTIFICATION OR FURTHER SITE -SPECIFIC DESIGN. 6. ALL WELDED CONNECTIONS SHALL [BE WELDED WITH AN INERT -GAS -SHIELDED ARC OR RESISTANCE WELDING PROCESS (AS PER SECTION 02003.8,13, F•B.C. 2004). ALL WELDING OF STRUCTURAL ALUMINUM MEMBERS SHALL BE PERFORMED BY A CERTIFIED WELDER (AS PER SECTION 02003.8.1.4, F.5.C. 2004). 1. COPIES OF THIS ENGINEERING DESIGN DETAIL SPECIFICATION DRAWING (ALL SHEETS) ARE ONLY TO BE VALID FOR PERMITTING PURPOSES OR FOR DESIGN CERTIFICATION PURPOSES WHEN ALL SHEETS OF'ANY•SUBMITTED, SET BEAR THE ENGINEER'S ORIGINAL SIGNATURE (IN BLUE INK) UNDER HIS EMB05SED' SEAL. NO 6ET5•.0F 1'IHE5E FA5CIA.ATTACHMENT NOTE: I. FOR ATTACHMENT OF ANY SOLID ROOF STRUCTURE TO THE -FASCIA OF THE. EXISTING HOST STRUCTURE, THE FASCIA BOARD MUST BE A NOMINAL 2' THICK BOARD (INSTALLATION ON A I x FASCIA BOARD 15 POSSIBLE IF THERE 15 A 2 X SUB -FASCIA, WHICH MUST BE VERIFIED PRIOR. -TO ANY. INSTALLATION BY THE CONTRACTOR). 2. THE 'FASCIA -TO -TRUSS TAIL' CONNECTION MUST BE - - REINFORCED BY THE PLACEMENT OF ONE (1) 1/4' x 4' I AG SCREW THROUGH THE FASCIA AND INTO EACH TRUSS TAIL (FOR THE ENTIRE LENGTH OF FASCIA THAT SHALL HOST A PROPOSED SOLID ROOF STRUCTURE. THESE LAG SCREW HOLES MUST BE PILOT -DRILLED WITH A 5/32' DRILL BIT (TO PREVENT SPLITTING OF THE TRUSS TAIL). THE CONTRACTOR SHALL BE RE- SPONSIBLE FOR LOCATING THE TRUSS TAILS ON THE JOB' SITE. IF REQUESTED, THE CONTRACTOR MUST BE ABLE TO PROVIDE ANY NECESSARY EVIDENCE NEEDED TO VERIFY ACTUAL PENETRATION OF THESE LAGS INTO THE TRUSS TAILS IF REQUESTED TO D SO BY EITHER THE ENGINEER OF RECORD OR ANY BUILDING OFFICIAL. 3. THE EXISTING HOST STRUCTURE'S OVERHANG SHALL NOT EXCEED 2' 0' (24 INCHES). IF THE OVERHANG DOES EXCEED THIS DIMENSION, ALTERNATIVE SUPPORT ,AND ATTACHMENT SPECIFICATIONS MAY NEED TO BE DESIGNED BY THE ENGINEER OF RECORD. HOST STRUCTURE (WALL / FASCIA) SPECIFICATION DRAWINGS SHOULD BE ACCEPTED, OR CONSIDERED VALID IF,THE DATE UNDER THE EMBOSSED I SIDE SCREEN SEAL IS MORE THAN 90 DAYS OLD. WALLS(RELOW) -��+ I $. ANY ORIGINAL SIGNED (IN BLUE INK) AND SEALED SITE -SPECIFIC DESIGN DRAWINGS, ALONG WITH .ITS SITE- n- gI SPECIFIC SPECIFICATIONS, SHALL ONLY SUPERSEDE THESE DESIGN SPECIFICATION DRAWINGS, WHEN IT IS i lac SPECIFICALLY STATED ON THE SITE DRAWING AND THAT SITE DRAWING 15 DEFINED AS A 'SITE -SPECIFIC' a I {° ROOF LOAD GEARING I DESIGN. u I jWALL (BELOW) 9. SCREEN DOOR(5) MAY BE PLACED INTO ANY 5CREEN WALL PANEL, AS PER OWNER'S SELECTION. EACH DOOR - MUST BE SELF -CLOSING AND SELF -LATCHING. CONCRETE ANCHOR SPECIFICATIONS: ALL CONCRETE ANCHORS SPECIFIED ON TH15 DETAIL�__�_ SHEET ARE MANUFACTURED BY 'REID HEAD' ANCHORING SYSTEMS, AS ALL LOAD CAPABILITIES ARE BASED ON TEST DATA FURNISHED fBY RFD HEAD IN THEIR PRODUCT AND RESOURCE BOOK. NO SUBSTITUTIONS OF ANY.OTHER MANUFACTURER'S CONCRETE ANCHORS IS PERMITTED WITHOUT SUBMITTAL OF THE COMPANY'S TEST DATA (TO VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN, SIGNED AND SEALED LETTER OF AUTHORIZATION FROM THE ENGINEER OF RECORD. ANY UNAUTHORIZED ANCHOR SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH THIS DESIGN. THE ANCHORS TO RE USED FOR APPLICATIONS SPECIFIED IN THIS ENGINEERING DESIGN PLAN ARE AS FOLLOWS: 1/4' DIA FASTENERS: RED HEAD ITW TAPCON, WHICH SHALL HAVE A MINIMUM EMBEDMENT INTO CONCRETE OR C.B.S. WALL OF 13/4'. 3/8', 1/2', 5/6' E 3/4' DIA. FASTENERS: ALL FASTENERS OF THESE DIAMETERS SHALL BE 'RED- HEAD TRUBOLT WEDGE' ANCHORS. SEE TOOTER PAD KEY' TABLE FOR INDIVIDUAL FASTENER EMBEDMENT5 AND MINIMUM EDGE AND CENTER-TO-CENTER'DIMEN510N5 (UNLESS OTHERWISE 5PECIFIED BY THE ENGINEER) UPRICsHT BEAM CANTILEVER Q SPACING 255o OF ALLOWABLE ,COLUMN SPACING: (MAXIMUM) - 5TANDARD SCREEN ROOM SCHEMATIC HOST STRUCTURE (WALL / FASCIA) SUPPORT COLUMN INTERMEDIATE I (INTERIOR) I CARRIER BEAM .I I - -------n--------- I I I I COLUMN I BEAM CANTILEVEF 1 SPACING I 25% OF ALLOWABL SCREEN WALLS -may COLUMN SPACING (BELOW) I (MAXIMUM) I (BEE SCHEMATIC ABOVE) I 6-- ----a---------- ex N 5TANDARD SCREEN ROOM WITH -INTERMEDIATE CARRIER BEAM ALLOWABLE ROOF PANEL SPANS THE SPANS INDICATED IN THE TABLES BELOW ARE BASED ON A LIVE LOAD OF 30 P.S.F., AND THE APPLICABLE WIND LOAD, AS DEFINED IN TABLE #2002.4, CHAPTER 20, FLA. BLDG. CODE 2004. ALLOWABLE DEFLECTION SHALL BE L / 120, AS SPECIFIED IN TABLE 016W.1, CHAPTER 16, FLA. BLDG. CODE 2004 (FOR NON -HIGH VELOCITY HURRICANE ZONES). MAXIMUMS HEIGHTS SHALL BE 30 FEET OR LESS FOR EXPOSURE "B"- AND15 FEET OR LESS. FOR EXPOSURE'C".- 3-INCH RISER PANS PANS SHALL BE ROLL -FORMED, IN ACCORDANCE WITH INDUSTRY STANDARDS, AND SHALL BE MADE FROM ALUMINUM ALLOY #3105- H14 OR ALLOY431SH28 (2 RIB MINIMUM). ROOF.PANEL OVERHANaG'�n PANEL THICKNESS ..024 .032 .040 2' 00 MAXIMUM 10' 8' 12101 12' 8' 3"�4"AND 6° INSULATED PANELS THE INSULATED ANEL SPANS INDICATED IN THE TABLE BELOW ARE THOSE THAT ARE SPECIFIED BYE PANEL PRODUCTS.(FLA STATE PRODUCT APPROVAL #F1,7561, DWG. NO. FL-1001, AS PRODUCED BY DO KIM a ASSOCIATES, LLC, CONSULTING ENGINEERS) IF A CONTRACTOR CHOOSES TO USE ANOTHER MANUFACTURER'S PANELS, THEY SHALL. STILL BE LIMITED BY THESE SPANS, AS THESE SPANS ARE THE BASIS FOR ALL OF THE DETAILS INDICATED WITHIN THIS ENGINEERING SHEET. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING THE OTHER MANUFACTURER'S PRODUCT APPROVALS. ALLOWABLE SPANS WITP 1 LB DENSITY CORE MATERIAL OVERHANG INSUI k D PANEL THICKNESS ! SKIN THICKNESS 3" 1.024 " / .032 140 / .024, 4" / .032 6" / .024 6" / .032 2'0",MAXIMUM 10' 9' 14' ®' 12',6' I1' 4' 1511. 2116, ALLOWABLE SPANS WITH 2 LB DENSITY CORE MATERIAL OVERHANG 30 / .024 3" / .030 4" /-.024- 4" 1.030 6" / .024 6" /.030 2' 0" MAXIMUM 16' 3' 11' ' 6 IV ' 6 22' 6' 22' 4' 22' 9° "CLEAR SPAN" SCHEMATIC DIAGRAM LV 'CLEAR SPAN' 'OVERHANG' BEAM AND COLUMNS (TVP.) ROOF PANEL SCREW SPACING AND EDGE DISTANCE 6PEC.'5 THIS TABLE IS BASED ON THE PROPERTIES OF G-1022 LOW CARISON STEEL SMS AND SELF -DRILLING (TEK) SCREWS, WHICH ARE AN INDUSTRY STANDARD SCREW, SCREW 61ZE NOMINAL SCREW DIAMETER (IN.) MIN. EDGE DISTANCE MIN, CENTER -TO - CENTER D15TANCE: $8 0.156 -- I D/16' 1/16' #10 0.188 3/8, 1/2' 012 0.219 1/2' 5/6' o14 0.250 5/8'1 3/4' FOR BRICK PAVER INSTALLATION: FOR INSTALLATION ON A BRICK PAVER DECK, PLEASE NOTE ALL COLUMNS MUST BE MOUNTED DIRECTLY TO THE CONCRETE FOOTER PADS (THE BRICK PAVERS CAN BE CUT TO FIT UP TO AND AROUND EACH COLUMN). THIS DESIGN DOES NOT PERMIT INSTALLATION OF THE SUPPORTING COLUMNS ON Top OF THE PAVERS, AS THE DESIGN LOADS WILL NOT ADEQUATELY RE RESISTED. �W�2 aF�w -0, w ww(9 n M 2 R Joo e w -1 `I RA G, � t� Luce -40 ® w� � 2 aj � Lj LU Co coo, n C) Cc w 2 n U= a 8 m La e - � �. W �uj cj �. � w =in z 03 ' a r- L9LLI V'2� qp^�,�� ALL. z c�a ®W a� C 7. �WCU ALLOWABLE FRONT WALL UPRIGHT SPACING. BASED ON ROOF SPAN MAXIMUM UPRIGHT SPACING FOR ROOF LOAD BEARING (FRONT) SCREEN WALL (CNTR-TO-CNTR) ROOF CLEAR 2 x 3 x .090 CARR, BM. 2 x 5 x .125 CARR. BM. SPAN VON O.H. 2 0" O.H. VON O.H. 2' 0' O.H. 6' 0' T 5° 990 8' 0' (') 8' 0' (°) 8' 0" 61100 615, 8' 0" (*) 8' 0° (� 10' 0' 8' 6" 6' 1" 8' 0' (') 8' 0' (') 12' 0' (Y 2" 5' 10' 8' 0" (7 8' 0" (`) 14' 0" 5' 11" 6189 8' 0" (°) 8' 0" e) 15' 0" 5' 9" 5' 7" 8' 0" 16' 0" 5' 8" 5' 5" 8' 0' (') 8' 0® (') 17' 0" 5' 7' V 4' 8' 0" (') 8' 0" (') 18,0" 5'6" 5'3" S'0"(°) 7'11" i9' 0" 5' 5" 6' 2" 8' 0" (') TO" MAXIMUM UPRIGHT HEIGHTS BASED ON UPRIGHT SPACING WALL COLUMN SCHEDULE (ALLOW. COLUMN HEIGHTS VS. WALL PANEL WIDTH) LM MAX. ALLOWABLE DEFLECTION (140 MPH, EXP.'B', 21 P.S.F. DESIGN LOAD) DIMENSION COLUMN HEIGHT vs WALL PANEL WIDTH (DESIGN PRESSURE = 21 PSF) SIZE Tf Tw 8' 0' T 6' T 0' 6' 6' 900 5' 6' 5' 0" 4' 6' 4' 0' 2x4 L .100 .045 1' 5' T 8' a,- m' 8' 3' V 1' v 0' 9' 5' 9' II' 10' 5' 2x5 L .116 .050 9' 0' 9' 4' SIB' 10' 0' 105' 10' II' WE,' 12' 0' 12' 9' Z O L .120 .050 9' 4' 9' 8' 10' 0' 10' 5' 10' 9' II' 3' I I' 10' 12' 5' 13' 2' 2x7 L 1 .120 .057 10' 2' 10' 6' 10' 11' II' 3' 11' Y IT 3' 12' II' 13' 6' 14' 4' 2x8 L ZA .072 12' 6' 12' 11' 13' 3' INS' 14141 15' 0' 18' 10, 19' 10' 21,01 2x9 L .209 .072 15' 0' 15' 1' 16' 1, 16' 8' 11' 4' IS' 2' 19' 0' 20' 0' 21' 2' 24 L (H) M .082 is, 1' 19' 2' IS' II' 20' 1' 21' 5' 22' 4' 23' 5' 24181 26' 2' 2x10 L 389 .092 22- 0' 22' 9' 23' 6' 24' 4' 25' 4' 26' 5' 21' 8' 29' 1' 30' S' THE UPRIGHTS SPECIFIED IN THIS TABLE ARE DESIGNED FOR PLACEMENT UNDER A SOLID ALUMINUM ROOF STRUCTURE, AND ARE BASED ON A DESIGN LIVE LOAD (ROOF) OF 30 P.S.F (DESIGN BASED ON A WORST -CASE OF A CLEAR SPAN OF 19 W) THE UPRIGHTS SPECIFIED IN THIS TABLE ARE DESIGNED FOR USE WITH SCREEN CLOTH WITH MAXIMUM DENSITY OF 18 x 14 MESH (58% OPEN, MINIMUM). (`) NO SCREEN WALL PANEL SHALL EXCEED 8' 0" CENTER TO -CENTER BOTH CARRIER BEAMS SPECIFIED ON THE UPRIGHT SPACING TABLE ABOVE ARE TO BE TUBE -TYPE CARRIER BEAMS (NOT S.M.B.) IF A PROPOSED ALUMINUM ROOF EXCEEDS IT 0" CLEAR SPAN, IT MUST BE DESIGNED SITE -SPECIFICALLY BY THE ENGINEER OF RECORD FOR THIS DESIGN DOCUMENT MINIMUM FOOTER TA15LE5 FOR PERIMETER-5GRE.EN FALLS MONO MAX. ROOF FOOTER SPAN 8' x 8' WITH lU K5� .CONY. UP TO 14' 8' x 12' WITH (I) SO CONT. 14' TO 11' 10' x 12WITH IT TO 20' (U "50 CONT. ISOLATED MAX. ROOF FOOTER(l) SPAN 12' x 14' WITH (D r54 CONT. UP TO 14' 14' x 16° WITH (2) Soo CONT. 14' TO Il' 16' x 16' WITH 11' TO 20' (2) N50 CONY. IF A JOB EXCEEDS THESE PARAMETERS; THE FOUNDATION MIDST BE BITE -SPECIFICALLY DESIGNED BY THE ENGINEER MONOLITHIC FTG. LOAD CAPACITIES ARE BASED ON A MIN. OF 3 FEET OF CONT, CONCRETE, 2,500 PSI MINIMUM, W/ WIRE OR FIBERMESH REINFORCEMENT (0150LATED FOOTERS MAY BE USED _6N EDGE OF EX15T: CONC: SUAB, OR UNpERNEATN THE PERIMETER OF BRICK PAVER DECK (ALL SIDES) COMPONENT SHAPE6 AND SPECIFICATIONS .010 2' 2x3'14' .010 M 3' 3x3'N' .044 ^� :040 ^E 3' 2' 1x30.5. Ix20.5. SELF -MATING ("L') THE ACTUAL VALUES FOR 'Tf' (FLANGE THICKNESS) AND 'Tw' (WE5 THICKNESS) FOR THE VARIOUS 512E SFLF-MATING MATERIAL ARE INDICATED ON THE UPRIGHT HEIGHT AND CARRIER BEAM TABLES. ALL "TUBE' TYPE BEAMS OR COLUMNS SPECIFIED IN THIS ENGINEERING DESIGN DOCUMENT SHALL HAVE THE SAME WALL THICKNE55 ON ALL FOUR 51DES (TYP). OVER CLEAR SPAN CLEAR SPAN OVER ZAP HOST STRUCTURE(WALL /FASCIA) s ANG MAX [�WALLS ROOF LOAD BEARING I MAX (51rLOW) �I I GABLE) i 51DE SCREEN RIDGE BEAM --- I WALLS (BELOW) I I I tu - -3-9 1/2 OF 1 lie OF CLEAR CLEAR d SPAN SPAN Ito RIDGE BE AM TRIBUTARY AREA N GABLE PLAN VIEW NOTE: r a COLUMNS THAT SUPPORT CARRIER BEAMS (INCLUDING RIDGE BEAMS FOR GABLE ROOFS) AND ARE WITHIN A w SCREENED WALL PANEL SHALL BE SELECTED FROM a THE MALL COLUMN SCHEDULE' ON THIS SHEET. o SEE DETAIL BELOW 12 3 MAX. COLUMN SPACING NOTE: GABLE ELEVATION MAXIMUM PITCH FOR GABLE ROOF SHALL BE 3 :12 GABLE ALUMINUM ROOF SCHEMATIC DIAGRAM 2 x 2 TOP RAIL (TYP. FOR TOP J OF SCREEN WALL PANEL THAT IS UNDER ALUMINUM ROOF PANEL I x 2 SCREEN FRAME (ON EITHER 51DE OF THE CARRIER BEAM SUPPCRT COLUMN) - OUTER SCREEN WALL SURFACE SEE 'TYP. GABLE ROOF DETAIL' FOR SPEC.'S 2 x 2 TOP RAIL (TYP. FOR TOP — OF SCREEN WALL PANEL THAT 15 UNDER ALUMINUM ROOF PANEL I x 2 SCREEN FRAME (ON EITHER SIDE OF THE CARRIER BEAM SUPPORT COLUMN) rn al N SIDE VIEW ROOF PANEL (TYP.) GABLE RIDGE BEAM AS SIZED FROM CARRIER BEAM TABLE 2 x 2 x .125 ANGLE (2' LONG) W/ FOUR (4) 92 TEKS INTO COLUMN AND FOUR (4) 012 TEKS INTO THE BOTTOM OF CARRIER BEAM, TYP ONE ANGLE ON BOTH THE INSIDE AND OUTSIDE OF THE COLUMN 4' x 8' x 3/16' THICK PLATE WITH NINE (9)'14 TEKS INTO SIDE OF CARRIER BEAM AND NINE (9) 014 TEK5 INTO SIDE OF -UPRIGHT, TYP. ONE PLATE ON EACH SIDE OF THE BEAM -TO -UPRIGHT CONNECTION (TEKS TO BE SPACED AS SHOWN) SCREEN WALL SUPPORT COLUMN FOR GABLE RIDGE BEAM (ALSO APPLICABLE TO OTHER INTER- MEDIATE CARRIER BEAM SUPPORTS) ALUMINUM ROOF PANEL (TYP.) GABLE RIDGE BEAM AS SIZED FROM CARRIER BEAM TABLE 4' x 8' x 3/16' THICK PLATE WITH NINE (S) 14 TEKS INTO SIDE OF CARRIER BEAM AND NINE (9) 014 TEK5 INTO SIDE OF UPRIGHT, TYP. ONE PLATE ON EACH SIDE OF THE BEAM -TO -UPRIGHT CONNECTION (TEKS TO BE SPACED AS SHOWN) SCREEN WALL SUPPORT COLUMN---- � 12 x 2 x .125 ANGLE (2' LONG) W/ FOR GABLE RIDGE BEAM (ALSO FOUR (4) 012 TEK5 INTO COLUMN APPLICABLE TO OTHER INTER- AND FOUR (4) "12 TEKS INTO THE MEDIATE CARRIER BEAM SUPPORTS) BOTTOM OF CARRIER BEAM, TYP. FRONT VIEW ONE ANGLE ON BOTH THE INSIDE AND OUTSIDE OF THE COLUMN GABLE MIDGE ISEAM-TO- 6CREEN WALL-. 6UPPOIRT COL.---- 2 �S2(9L� a—�m Z 0S2 0� W W n. u_>-Iea at 3�mLa C W ���c ' OCR 0 OLL, 0 V z zx8 MAXIMUM BEAM SPANS FOR INTERMEDIATE (INTERIOR) CARRIER SEAMS CONTRIBUTING ROOF LOAD WIDTH (TRIBUTARY AREA) (SEE SCHEMATIC LAYOUTS ON SHEET #1 FOR DESCRIPTION) CARRIER BEAM SUES S0" C0" 7'0' 810' 90' 10'0" 11'0' 120" IT ON 14'W 15'0" 1&0" IT0' 18,T 190' 2 x4 SNAP x.045 x.045 W 3' (A) 5' 8' (A) 5' 3' (A) 4' 11' (A) 4' 6' (A) 4' 5' (5) 4' 2' (6) 4' 0' (B) 2 x 3 TUBE x.093 x.093 #T 0' (A) -6' T (A) 6' 0' (A) 5' 8° (A) 5' 4(A) 5' 1' (5) 4' 10' (B) 4' T(B) 4' 5' (5) 4' 3' (5) 4' I' (B) 2 x 4 LAP x.045 x.100 8' 0' (A) T 4' (A) 6' S' (A) 6' 4' (5) 6' 0' (5) 5' 8' (5) 5-5-(5) 5' 2' (5) 5' 0' (B) 4' S' (B) 4' 8' (B) 4' 6' (6) 4' 4' (5) 4' 3' (15) 4' P (T3) 2x5LAPx.050x.116 S' II' (A) S' I' (F3) 8' 5' (5) T 10' (5) T 5' (5) T 0' (13) 6' 8' (5) 6' 5' (5) W 2' (C) 5' 11' (C) 5' S' (C) 5' T (C) 5' 5' (C) 5' 3' (C) 5' 1' (C) 2 x8 LAP x.050 x.120 11' 4' (5) 10' 5' (5) V T (B) S' 0' (5) 8' 6' (5) 8' 0' (C) T 8' (C) T 4' (C) T P (C) 6' 10, (C) 6' T (D) 6' 4' (D) 6' 2' (D) 6' 0' (D) 5' 10, (D) 2x5TUBEx.125x.125 °II' T (5) 10' 10' (5) 100' (5) V 5' (5) 8' IV (C) 8' 5' (C) 8' 0' (C) T 10' (C) T 4' (C) T I' (D) 6' 10' (D) 6' 8' (D) 6' 5' (D) 6' 3' (D) 6' 1' (D) 2 x 7 LAP x.057 x.120 12, 1], eM) III S' (5) 10' 11' (5) 10, 21 (c) S' 1' (C) S' I° lC) 6' 8' (C) 8' 4' (D) 8' 0' (D) T 8' (D) T 5' (D) T 2' (D) T O' (D) 6' 10, (D) 61 11 (D) 2x8LAP x.072x.224 14' T (5) 13' 4' (C) 12' 4' (C) 11' 6' (C) 10' II' (D) 10' 4' (D) V 10' (D) S' 5' (D) S' I' (D) 8' S' (D) 6' 5' (D) 6' 2' (D) T 11' (D) T 6' (D) T 6' (E) 2x9LAP x.082x.306 21' 8' (D) 19' 9' lD) 18' 4' (D) 11' 1' (D) IV. 2' (E) 15' 4' (E) 14' T (E) WO' (E) 13' 5' (F) 12' 11' (F) 12' 6' (F) 12' 1' (F) II' 9' (F) II' 5' (F) II' 1' (F) 2 x 10 LAP x.092 x.389 -24' 4' (0) .22, 10, (0) 21' 6' (E) 20' 2' (E) IS' 0' (F) 18' 6' (F) 11' 2' (F) 16' 5' (F) 15' S' (F) 15' 3' (F) 14' 8' (F) 14' 3' (F) 13, S' (G) 13, 5' (G) 13, 1' (G) DBL. 2x9LAP x.082x.30S 26' 6' (D) +25' 0' (E) 23' S' (E) 22' 8' (F) 21' 10' (F) 21' 1' lF) . °20' 5' (F) ITS' (G). IS' 0' (G) 16' 4' (6) 11' 8' (G) 11' 1' (H) 16' T (H) IV 2' (H) 15' 8' (H) DBL. 2x10LAP x..092x.389 60' T (E) 128' 10' (F) -21' 4' (F). s26' 2' (F) #25' 2' (F) '24' 4' (G) 123, 1' (G) 022' 10' (H) 22' 3' (14) 21' W (H) 209' (H) 20' 2' (H) 19' 6' (H) 19' TABLE NOTES: 1. V) DENOTES DIMENSIONAL VALUES THAT ARE DEFLECTION -LIMITED (AS PER F.B.C. 2004), ALL OTHER DIMENSIONAL VALUES ARE STRESS -LIMITED. 2. THE LETTERS SHOWN IN PARENTHESIS CORRESPOND TO THE 'FOOTER PAD KEY" (SEE BELOW), AND REPRESENT THE MINIMUM FOOTER PAD SIZES NEEDED TO RESIST THE IMPOSED UPLIFT: LOADS, AS DETEkMINED BY ROOF'TRIBUTARY AREA AND COLUMN SPACING (BASED ON A DESIGN UPLIFT LOAD OF 24 P.S.F.) 3. ANY SITE -SPECIFIC PARAMETERS THAT EXCEED THE VALUES INDICATED IN THIS TAI3LE SHALL BE REDIRECTED BACK TO THE ENGINEER OF RECORD FOR ADDITIONAL SITE -SPECIFIC STRUCTURAL. ANALYSIS AND DESIGN. 4. THE DIMENSIONAL VALUES INDICATED IN THIS TABLE REPRESENT THE MAXIMUM ALLOWABLE CENTERJO-CENTER LOCATION FOR THE PRESCRIBED VERTICAL SUPPORT COLUMNS PLACED UNDER ANY OF. THE GIVEN CARRIER BEAMS. FOOTED PAD KEY MINIMUM COLUMN SIZE ALL CONIC ANCHORS RED -HEAD SPECIFIED IN THIS TABLE SHALL BE WEDGE" ANCHOR (SEE NOTE, SHT #1) MINIMUM CNTR TO-CNTR DISTANCE MAX ALLOW. LOAD (PER ANCHOR) (TENSION). ) SEE ANCHOR DETAIL # (SKEET #6) NUMBFJiAND SIZE OF THRU-BOLTS FOR CARRIER BEAM -TO - COLUMN CONNECTION NUMBER OF CONC. ANCNOR3 ANCHOR SIZE MINIMUM EMBED. MINIMUM EDGE DIST. S'v®nSU FOO cR PAD SIZE "A" T 0' SQUARE x 2 0" DEEP 3' x 3" x.125" COLUMN TWO (2) 3W DIA. 3" 3" 8' 1,175 LBS 01 TWO (2) W. DIA. BOLTS "g" 26" SQUARE x 2' 0' DEEP 3' x 3' x.125" COLUMN TWO M - 318' DIA. 3" 3" 6" 1,175 LBS # 1 TWO (2) 318" DIA. BOLTS To 2 6" SQUARE x 2' 6' DEEP Tx T x .125" COLUMN— TWO; (2) 318" DIA 4® 3' 8" 1.340 LBS # 2 TWO (2) 31W DIA. BOLTS "D" VON SQUARE x 2' 6" DEEP 3' x 3" x .125' COLUMN TWO (2) 1/2" DIA. 410 31/4" 6114" 1,787 LBS # 3 THREE. (3) 3V DIA. BOLTS "Ea TO" SQUARE x 3"IF DEEP T x 3" a .125" COLUMN �-L TWO7(2)-- SW DIA 5AWL 89 ---2,140 LSS # 4 .. THREE '(3)1IT: DIA. BOLTS "F" 3' 6" SQUARE x T 0' DEEP 4' x 4' x .125" COLUMN TWO (2) 314' DIA. 6 518" 5' 7" 2,9W LBS # 5 THREE (3) SM' DIA. BOLTS "T 3' 6" SQUARE x V 6" DEEP 4' x 4' x .25T COLUMN FOUR (4) 1/2' DIA. 41f6" 31/4" 81/4" 1,757 LBS # 8 FOUR (4)1/2" DIA. BOLTS 4' 0' SQUARE x T 6' DEEP 4" x4" x .250" COLUMN FOUR (4) 50 DIA. 51/8" 4' 6" 2,140 LBS 47 FOUR (4) 50 DIA. BOLTS 4' 0" SQUARE x 4' 0' DEEP 4° x V x .250" COLUMN FOUR (4) 3/4" DIA ear 5' 10' 3,560 LBS 08 FOUR (4) 314' DIA. BOLTS "Jp 4' 3' SQUARE x 4' T DEEP 4' x 4' x .250" COLUMN FOUR (4) 314' DIA. 6 5w 5' Ur 3,580 LBS # 8 FOUR (4) 314- DIA BOLTS ALL FOOTER PADS SHALL HAVE #5 BARS (VOTH 37INCH MINIMUM CONCRETE COVERAGE AT EACH END), PLACED AT 6-INCHES CENTER TO -CENTER, IN EACH DIRECTION, TO BE PLACED 6 INCHES ABOVE THE BOTTOM OF THE FOOTER PAD (TYPICAL FOR ALL FOOTER PADS). BEAM SPLICE LOCATION -SCHEMATIC TYP• BEAT ALLOWABLE SPLICE TYP. CARRIER TYP. 3/16 LOCATION OPTIONS BEAM / 1/4' THI( TYPICAL SUPPORT COLU41NS PLATE a d STITCH SCREWS SHALL BE 014 TEK5 a 18' D.C., TYP. BOTH TOP AND BOTTOM FLANGE OF ALL SM.B. CARRIER BEAMS 41 51NGLE 5.M.5. CARRIER BEAM STITCH 6CREW5 SHALL BE 014 —` TEK5 a 18' O.C., TYP. BOTH TOP AND BOTTOM FLANGE OF ALL S.M.B. CARRIER BEAMS TWO INNER HALVES OF DOUBLE .BEAMS $HALL BE ATTACHED WITH TWO ROWS OF 94 TEK5 s 18' O.C., EACH TO BE STAGGERED FROM THE OTHER ROW, SO THERE WILL BE ONE SCREW EVERY NINE _ INCHES OVERALL. (CONT. OVER ENTIRE LENGTH OF BEAM) STITCH SCREWS SHALL BE 114—� TEK5 0 18' O.G., TYP• BOTH TOP AND BOTTOM FLANGE OF ALL S.M.B. CARRIER BEAMS 0• W. G �— .. 12' PLATE WIDTH ALL SCREWS SHALL I' 2' 2' 22' 1' BE 14 TEK SCREWS a Lu '' II o 0 01 s oc -�' o O 0 0 O O CARRIER SEAM SPLICE DETAIL (FOR 2 x 6 BEAMS AND SMALLER) USE 3/16" THICK PLATE FOR THIS ,APPLICATION do Zd � TYP. CARRIER u � m SPLICE PLATE TOLERANCE NOTE:_ SEAM (SM. B.) w ALL SPLICE PLATES (ALUMINUM ALLOY 06063-T6 or 060(61-T(o) SHALL 5E CUT TO 5E +0.000 / TYP. 3/16, ri -0.0625, AS INDICATEI) IN THE / 1/4' THICK PLATE SCHEMATIC DRAWINGS AT LEFT I'i w�E fa mw is 1' MIS ao 10 0 i 0 0 0 o 0 ALL SCREWS SHALL BE °14 TEK SCREWS 01 �E of =? I aQ 01 �a 0 0, —BEAM SPLICE CARRIER BEAM SPLICE DETAIL (FOR 2 X 7 BEAMS AND LARGER) USE 1/4" THICK PLATE FOR THIS APPLICATION FOR SPLICES ON A SM.B. CARRIER BEAM, THE ACTUAL `j ` ` V v ' SPLICE ON -EACH HALF OF_THE BEAM MUST BE POSITIONED IN A DIFFERENT LOCATION (BOTH 5PL1cE5 SHALL NOT -NOTE: THESE CARRIER BEAM 5FLICE SPECIFICATIONS ALSO APPLY TO CARRIER-15EAM5 UTILIZED WITH A SCREEN WALL BE IN THE SAME LOCATION) LLI IUJ �� z o ®U4a rem zvi lidTs� DIA. THRU-BOLT, WITH FENDER — WASHER ON TOP SURFACE AND NUT AND WASHER ON BOTTOM, TO BE PLACED AT 8 INCHES O.C. (SIX (6) BOLTS PER 4-FOOT WIDE ROOF PANEL, MINIMUM) INSULATED ALUMINUM INSULATED ALUMINUM ROOF PANEL (TYP) ROOF PANEL (TYP) 0 4' x 4' LAG SCREW W/ FEND u WASHER (HOLE TO BE PILO' 0 DRILLED WITH A 5/32' BIT),' N12 TEK SCREWS W/ 5/8' PIA. (MIN.) WASHER AT 3' O.C. (4 PER 12-INCH WIDE PAN) 3-INCH RISER PAN - ROOF PANEL (TYP) 2 x 2 x .125 ANGLE ICONTJ OUTSIDE OF THE ANGL BE INSTALLED a 8' D.C. (SIX (6) ATTACHED TO 2 x 3 x ,090 LAGS PER 4-FOOT WIDE PANEL) CARRIER BEAM WITH TWO ROWS OF 014 TEKS, EACH ROW LOAD -BEARING SCREEN WALL AT 18 INCHES O.C. (EACH ROW COLUMN (BEYOND) (SEE COL - SHALL BE STAGGERED, SO LOAD -BEARING SCREEN WALL UMN-TO-CARRIER BEAM DETAIL EACH TEK IS 9 INCHES APART) NOTE: FOR APPLICATION W/ COLUMN (EEYOND) (SEE COL- FOR SPEC.'S ON THIS CONNECTION) LOAD -BEARING SCREEN WALL CONT. 2 x 2 ANGLE, STRAPS SHALL BE PLACED ON THE UMN-TO-CARRIER BEAM DETAIL L INCH R15ER PAN COLUMN(EEYON[D)(SEE COL- (AS FOR SPEC.'S ON THIS CONNECTION) E FOR PEG'S OINRT IS CONNECTION) BEAM DETAIL �HO1�" INSULATED PANEL W/ LACE BOLTS INSULATED PANEL W/ THRU BOLTS ALUMINUM ROOF PANEL -TO -SCREEN WALL CARRIES' BEAM CONNECTION DETA1I-5 /— FRONT WALL 2 x 2 x 3/16' ANGLE, WITH FOUR (4) "12 TEKS INTO THE UPRIGHT AND ONE (U 3/8' RED -HEAP 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) SIDE WALL I x 2 05 BOTTOM FRAME I x 3 OEi 8iOE-WALL UPRIGHT I x 2 05 BOTTOM FRAME 2 3i4', MIN. ED DISTANCE 3 x 3 x .010 FRONT WALL GORIER UPRIGHT w 1010 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL A Z NOTE 03, SHEET 02) TO BE IS- z F INCHES,CENTER-TO-CENTER rZ MAX. SPACING �a Q FLOOR LEVEL FLAN VIEW I x 2 x l/8' ANGLE (3 INCHES 2 x 3 x .090 CARRIER LONG) WITH THREE (3) 012 TEKS INTO SIDE OF 3 x 3 x .010 CORNER BEAM (CONT.) UPRIGHT AND THREE (3) 012 TEKS INTO THE BACK OF THE CARRIER SEAM, TYPICAL BOTH ON THE- INSIDE 2 x 3 x .010 TOP FRAME AND OUTSIDE OF EACH 3 x 3 CORNER UPRIGHT I x 3 OE SIDE WALL CORNER— UPRIGHT 010 x 2' SMS SCREW, WITH 518' DIA. WASHER (SEE GENERAL NOTE 03, SHEET 02) TO BE IS - INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE (U 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) I x 2 OB BOTTOM FRAME 1/8' THICK STRAP, 11i2' WIDE x 6 INCHES LONG, WITH THREE (3) "12 TEKS INTO FACE OF CARRIER BEAM AND THREE (3) 112 TEKS INTO FRONT OF THE 3 x 3 x .010 CORNER UPRIGHT 3 x 3 x 210 FRONT WALL CORNER UPRIGHT 2 3i4', MIN. EDGE ° 01 1 DISTANCE ELEVATION VIEW CORNER SPECIFICATIONS 3-INCH RISER FL ROOF PANEL (TY 112 TEK SCREWS W/ 5/6' (MIN.) WASHERS, TO BE INSTALLED WITHIN 2 INCHES ON EITHER SIDE OF EA. COLUMN AND 8 INCHES O.C., MAXIMUM SPACING, INTO 2 x 3 H TOP SCREEN FRAME NOTE: . BOTTOM OF COLUMN CONNECTION IS THE SAME FOR EITHER TYPE OF ROOF SYSTEM. WITH 3 INCH R15ER PAN 114' x 4' LAG SCREW W/-1 FENDER WASHER, HOLE TO BE PILOT DRILLED W/ A 5/32' BIT, LAGS TO BE INSTALLED WITHIN 2 INCHES ON EITHER SIDE OF EA. COLUMN AND 6 INCHES O.C. MAXIMUM SPACING, INTO 2 x 3 H TOP SCREEN FRAME 2x3x.0l0HTOP — SCREEN FRAME (TYP. ALL RETURN (SIDE) WALL PANELS) 2 x 2 x 3/16' ANGLE (21— LONG) WITH FOUR (4) 012 TEKS INTO SIDE OF COLUMN AND ONE (U V RED HEAP TRUBOLT I x 2 BASE SCR WEDGE ANCHOR (3 INCH EMBED, MIN.), TYP. ONE ANGLE ON EACH SIDE 2 OF EA. RETURN WALL COLUMN 7NCRETE WITH IN5ULATED PANEL. INSULATED ALUMINUM ROOF PANEL (TYP) EDGE OF x 2 x 1/8' ANGLE (3' ONG) WITH FOUR (4) 2 TEKS INTO BOTTOM )F 2 x 3 H TOP FRAME SNP FOUR (4) 012 TEKS 4TO SIDE OF 2 x COL. TYP. ONE ANGLE ON ACH 51DE OF EACH RETURN (SIDE) WALL COLUMN) 2 x 5 SCREEN WALL COLUMN (MIN. FOR RETURN (SIDE) WALL APPLICATIONS FRAME (TYP) 3�4 � � 33�4, MIN. RETURN (51pE) WALL. CONNECTION 5FECIFICATION5 0 O O ROOF FASTENER LENGTH NOTE: WHEN THICKER INSULATED ROOF PANELS ARE UTILIZED, THE FASTENRS USED OT BOLT THEM DOWN SHALL BE AS FOLLOWS: 4-INCH THICK PANEL - 1/4" x (o' LAGS OR THRU-BOLTS 6-INCH THICK PANEL - 3/8' x l' LAGS OR THRU-BOLTS NOTE THAT FATENER SPACING SHALL REMAIN THE SAME AS THAT WHICH 15 SPECIFIED FOR THE 3-INCH THICK PANELS 2 x 2 x 1/8' ANGLE (3 INCHES 2 x 3 x .090 CARRIER LONG) WITH SIX (6) M2 TEKS BEAM (CONT.) (SEE - INTO SIDE OF'2 x 5 COLUMN I o II O II ®1 °CARRIER BEAM SPLICE AND TWO (2) 3/a' DIA. THRU I ®II 0 II ® 1 DETAIL' IF OVERALL BOLTS (W/ NUT AND WASHERS) o LENGTH OF BEAM THROUGH ANGLE AND CARRIER o REQUIRES A SPLICE) BEAM (TYP ONE ANGLE ON o EACH SIDE OF EACH FRONT O I/8' THK. STRAP, I':' WIDE x 6-INCHES LONG, WALL COLUMN) (SHOWN HERE WITH THREE (3) 012 TEKS INTO THE FACE OF BEHIND THE CARRIER BEAM) THE CARRIER BEAM AND THREE (3) 012 TEKS INTO THE FRONT OF THE 2 x 5 SMB UPRIGHT 2 x 5 FRONT WALL COLUMN (TYP. EACH COLUMN - TO - CARRIER BEAM (MIN. COLUMN SIZE FOR CONNECTION, INCLUDING 3 x 3 x .010 H FRONT WALL APPLICATION) CORNERS) FRONT VIEW (COLUMN 4 CARRIER BEAM) SEE 'ALUMINUM ROOF PANEL- 2 x 2 x 1/8' ANGLE (3 INCHES TO -SCREEN WALL CARRIER LONG) WITH SIX (6)12 TEKS BEAM CONNECTION [DETAIL' INTO SIDE OF 2 x 5 COLUMN FOR THESE SPEC.'S AND TWO (2) V DIA, THRU NANDACARRIER 2 x 3 x .090 CARRIER o ROUGH ANGLE BEAM (CONT.) (SEE 00 SEAM (TYP. ONE ANGLE ON 'CARRIER BEAM SPLICE 0 EACH SIDE OF EACH FRONT DETAIL' IF OVERALL WALL COLUMN LENGTH OF BEAM REQUIRES A SPLICE) TOP OF FRONT WALL COLUMN SHALL BE NOTNCED (2' x 3') 1/8' THICK STRAP, Ii7' TO RECEIVE 2 x 3 x ,090 WIDE x (oINCHES LONG, CARRIER BEAM (TYP.) WITH THREE (3) 012 TEKS I x 2 TOP SCREEN FRAME INTO FACE OF CARRIER (TYP,), ATTACHED. TO BOT. BEAM AND THREE (3) OF CARRIER BEAM WITH 012 TEKS, INTO FRONT OF �10 SM.S. (AS PER GEN. 2 x 5 COLUMN (TYP. EA. NOTE "3 ON SHEET 1) COL. -TO -CARRIER BM. CONNECTION, INCLUDING 2 x 2 CORNER COLUMNS) 2 x 2 x 3/16' ANGLE (2' LONG) WITH FOUR (4) 2 x 3 x .010 H CHAIR RAIL �12 TEKS INTO SIDE OF COLUMN AND ONE !U 2 x 5 FRONT WALL COLUMN 1V RED HEAD TRUBOLT (MIN. COLUMN SIZE FOR WEDGE ANCHOR (4 INCH FRONT WALL APPLICATION) EMBED, MIN.), TYP. TWO ANGLES ON EACH SIDE I x 2 BASE SCREEN OF EACH FRONT WALL FRAME (TYP) 0 0 COLUMN (ONE ON TOP 0,0 OF I x 2 SCREEN FRAME AND ONE DIRECTLY ON THE CONCRETE, TO THE INSIDE OF THE COLUMN, EDGE OF CONCRETE MIN, TO MAINTAIN A 3-INCH CNTR-TO-CNTR DISTANCE ON THE TWO CONCRETE 3314' 3' ANCHORS ON EACH SIDE MIN. MIN. OF THE COLUMN) SECTION VIEW FRONT (VERTICAL LOAD SEARING) WALL -CONNECTION 5RECIFICATION5 u- ixw 0: it Z CL 5 w w C E �I�Lu15 �j�.Ir®�� a L gm W —� a OF—VZ—, WV30Ul 0 u�3 �0— ®� � C U co Z V 6 ®O IL 0 L- CL �W 5 Z �LLJZ EXTRUDED 1/8' Z-GUTTER INSERT 14' x 21/2' LAG (W/ WASHER) 6 )CUT 6 4' LONG) TO BE PLACED 16' O.C. MAX, (ONE LAG SHALL 32' O.C. (AT EVERY OTHER LAG) 13E INSTALLED INTO EACH 'Z- 1/4' x 4' THROUGH BOLT, W/ FENDER GUTTER INSERT) WASHER ON TOP SIDE, TO BE INST- ALLED is 8' D.G. (SIX PER 48-INCH HOST STRU(--T. PANEL) THROUGH 2 x 4 ANGLE FASCIA (TYP) INSULATED ALUM. SEE 'FASCIA ATTACH- ROOF PANEL (TYP) MENT NOTE' ON SHT. rl 112 TEK, TYP. 3 PER Z- GUTTER INSERT 2 x 3 x .093 ANGL 2 x 4 x 1/8' ANGLE (CONT.) WITH SPACER (CONT.) 1/4' x 11/4' THROUGH BOLTS 0 12' AS NEEDED FOR O.G. (ONE '50LT THRU EACH Z- ANGLED FASCIA, W/ GUTTER INSERT). ANGLE TO BE TWO ROWS OF 12 RAISED ENOUGH TO CLEAR h2 TEK SCREWS 6 18' TEKS IN TOP OF GUTTER O.C. (EACH ROW TO 3V x 6' LAG, PLACED THROUGH BE STAGGERED) A 3/4' x �44' FERRULE INTO FASCIA 5' STRUCTURAL GUTTER (TO BE PLACED a 32' O.C., MAX) (CONT.) (TO ALSO PASS THRU 2 x 4 ANGLE) (PILOT -DRILL FASCIA W/ 1/32 BIT) FASCIA WITH 5TRUCT. CUTTER (INSULATED PANES.) 1/4' x 21/2' LAG (W/ WASHER) to16' O.C. MAX. (ONE LAG SHALL BE INSTALLED INTO EACH I x 5 ANGLE) I x 5 x 1/8' ANGLE (CUT 4 INCHES LONG). PLACE ANGLE CLIPS AT HOST STRUCT. 32, O.C. (AT EVERY OTHER LAG) FASCIA (TYP) q2 TEK SCREWS, W/ 5/8' DIA. (MIN' WASHER, 3' O.C. (4 SEE 'FASCIA ATTACH--� PER 12-INCH WIDE PAN) WITH MENT NOTE' ON SHT. TWO.N2.71K5 (MIND INTO EACH "I I x 5.ANGLE CLIP B-INCH RISER PAN 2 x 3 x .OS3 ANGL ROOF PANEL (TYP) SPACER (CONT.) AS NEEDED FOR 3/e' x 8' LAG, PLACED THROUGH ANGLED FASCIA, W/ A 3/4' x 3/4' FERRULE INTO FASCIA TWO ROWS OF 012 (TO BE PLACED m 32' O.C., MAX) TEK SCREWS ®IS'_5' STRUCTURAL GUTTER (TO ALSO PASS __THRU _2 x 4 ANGLE) O.G. (EACH ROW TO (CONT.) (PILOT -DRILL FASCIA W/ 1/32 BIT) BE STAGGERED) FASCIA WITH STRUCT. CUTTER (3 INCH, RISER`. -PAN)`. ALUMINUM ROOFJO-FASGIA UJITH STRUCT. GUTTER -/4' x 2,/2LAG, W/ WASHEI MOBILE HOME SU5-FR9 5TRUCTURE a 12' O.G., MA EXIST. HOST MOBILE -- HOME (SEE NOTE BELOW RE: FOURTH WAIL INSTALLATION) 23/e' x 31/4' x 11/2' ALUM, ROOF HEADER (CONT) 3-INCH RISER PAN ROOF PANEL (TYP) P12 TEK SCREWS W/ 5/8' DIA. (MIN.) WASHER AT 3' O.C. (4 PER 12-INCH WIDE PAN) 112 TEKS a 4' O.C. (3 PER —� 12-INCH WIDE PAN) INTO BOTTOM OF PANS. AND CARRIER BEAM (SIZED FROM— - ONE lU 012 TEK INTO THE CARRIER BEAM TABLE) TOP OF EACH P15ER (IF ACCESS TO THE TOP OF THE RISER 15 LIMITED, 012 TEKS MUST BE INSTALLED m 3' O.C. (4 PER 12-INCH WIDE PAN IN THE BOTTOM FOURTH WALL CONNECTION WITH 3-INCH R15ER PAN 23/a' x 31/4' x IV2' ALUM.--1 ROOF HEADER (CONT) HOST STRUCT. FASCIA (TYP) SEE 'FASCIA ATTACH---�,,,_ MENT NOTE' ON SHT. M I x 2 x .093 ANGLE 1/4' x 2W LAG SCREW 23/a' x 31/4' x I1/2' ALUM. a (W/ WASHER), TO BE H05T STRUCT. ROOF HEADER (CONT) } INSTALLED is 1V O.C; WALL (TYP) (MAX.)ALUM. MA NSULATEq ALUM. ROOF PANEL (TYP)) P) u / ROOF PANEL (TYP) o SPACER (CONT.) AS NEEDED FOR M2 TEKS m 12' O.C. (4 PER ANGLED FASCIA, W/ 48-INCH PANEL) INTO TOP TWO ROWS OF M2 AND BOTTOM OF PANELS TEK SCREWS m IS' (WHERE ACCESS TO TOP O.C. (EACH ROW TO OR BOTTOM IS RESTRICTED, BE STAGGERED) 12 SHALL BE INSTALLED g 6' O.C. IN ONE SURFACE OR THE OTHER) FASCIA (IN5ULATEp PANEL) ONE (U 1/4' x 21/2' LAG, TO BE PLACED INTO EA. STUD (FOR WOOD FRAME) (MAXIMUM 24' O.C.) FOR CONC. / C.B.5, FABTNER SHALL BE %' DIA. RED- HEAD 'LDT' TAPCON, W/ A MIN. EMBEDMENT OF 13/4' INTO CONC. l G.B.S. WALL is IS' O.C. (MAX) $12 TEKS 0 12' O.C. (4 PER 48-INCH PANEL) INTO TOP AND 50TTOM OF PANELS (WHERE ACCESS TO TOP OR BOTTOM IS RESTRICTED, 112 SHALL BE INSTALLED a 6' O.C. IN ONE SURFACE OR THE OTHER) WALL (INSULATED PANEL) 23/a' x V/4' x I1/2' ALUM. 23/a' x 31/4' x 11/2' ALUM. 1/4' x 21i2' LAG SCREW HOST STRICT. ROOF HEADER (CONT) ROOF HEADER (CONT) (W/ WASHER), TO BE WALL (TYP) HOST STRUCT. INSTALLED g 16' O.C. (MAX.) 3 INCH RISER PAN FASCIA (TYP) ROOF PANEL (TYP) 3-INCH RISER PAN SEE 'FASCIA ATTACH ROOF PANEL (TYP) ONE el) x 21/2' LAG, MENT NOTE' ON BHT. TO BE PLACED INTO EA. "I STUD (FOR WOOD FRAME) 12 TEKS a 4' O.G. (3 PER (MAXIMUM 24' O.C.) FOR 12-INCH WIDE PAN) INTO I x 2 x ff93 ANGLE CONC. / C.B.S., FASTNER BOTTOM OF PANS AND SPACER (CONT.) SHALL BE 3/9' DIA. RED- ONE (I) 12 TEK INTO THE AS, NEEDED FOR 012 TEKS a 4' O.G. (3 PER HEAD 'LDT' TAPCON, W/ TOP OF EACH RISER (IF ANGLED FASCIA, W/ 12-INCH WIDE PAN). INTO A MIN. EMBEDMENT OF ACCESS TO THE TOP OF . TWO ROWS OF 012 BOTTOM OF PANS AND 13/4' INTO CONC. / C.B.S. THE RISER 15 LIMITED, 012 TEK SCREW5'19 IS' ONE (1) 012 TEK INTO THE WALL is IS' D.C. (MAX) TEKS MUST BE INSTALLED O.C. (EACH ROW TO TOP OF EACH RISER (IF to 3' O.G. (4 PER 12-INCH RE STAGGERED) ACCESS TO THE TOP OF WIDE PAN IN THE BOTTOM THE RISER 15 LIMITED, "12 TEKS MUST BE INSTALLED WALL (3-INCH R15ER PAN) g 3' O.C. (4 PER 12-INCH WIDE PAN IN THE BOTTOM ------___.-- -- FASCIA (3-INCH RISER PAN). _- 5TANPARp ALUMINUM }GOOF - TO - HOST 5TRUCTURE CONNECTION [DETAIL 1/4' x 211/2' LAG, W/ WASHER INTO MOBILE HOME SUB -FRAME STRUCTURE e 12' O.G., MAX. EXIST. H05T MOBILE—<::: HOME (SEE NOTE ABOVE RE: FOURTH WALL INSTALLATION) 012 TEKS ® 12' O.C. (4 PER- 48-INCH PANEL) INTO TOP AND BOTTOM OF PANELS (WHERE ACCESS TO TOP OR BOTTOM IS RESTRICTED, 012 SHALL BE INSTALLED e (a' O.C. IN ONE SURFACE OR THE OTHER) INSULATED ALUM. ROOF PANEL (TYP) ' 2%' x 3�/4' x V/2' ALUM. FILE A 'PY ROOF HEADER (CONT) 1/4' x 4' LAG SCREW W/ FENDER FOURTH WALL INSTALLATION NOTE: WASHER (HOLE TO BE PILOT- IF THE MOBILE HOME MANUFACTURER WILL PROVIDE WRITTEN DRILLED WITH A.5/32' BIT), TO AUTHORIZATION THAT THE MOBILE HOME WILL RESIST THE ADD - BE INSTALLED 9 S' O.C. (SIX ITIONAL LOADS (LIVE, DEAD OR UPLIFT) IMPOSED BY THE ALUM, LAGS PER 46-INCH WIDE PANEL) ROOF STRUCTURE, THE FOURTH WALL CARRIER BEAM AND COLUMNS (IF BEAM IS A SM.5., SEE ANGLE MAY BE OMITTED (ORIGINAL DOCUMENTATION MUST ACCOMPANY ATTACHMENT DETAIL, TO RE USED THE PERMIT PAPERWORK SUBMITTED BY THE INSTALLATION WITH S.M.B. CARRIER BEAMS) CONTRACTOR). CARRIER BEAM (SIZED FROM CARRIER BEAM TABLE) FOURTH WALL CONNECTION WITH INSULATED ROOF PANEL. FOURTH -WALL CONNECTION [DETAIL FOURTH WALL DESIGN NOTE: IN THIS FOURTH WALL DESIGN, THE FOURTH WALL BEAM AND COLUMNS ARE IN PLACE TO RE51ST THE IMPOSED LIVE LOADS, DEAD LOADS AND ALL UPLIFT LOADS IMPOSED BY THE ALUMINUM ROOF STRUCTURE. THE ATTACHMENT TO THE EXISTING HOST MOBILE HOME ONLY SERVES TO PROVIDE LATERAL STABILITY TO THE STRUCTURE. THIS DESIGN ALSO APPLIES IF THE CARRIER BEAMS) ARE PERPENDICULAR TO THE HOST STRUCTURE, WHERE THE END OF THE BEAMS) SHALL BE SUPPORTED BY VERTICAL COLUMNS, THE ROOF HEADER SHALL STILL BE ATTACHED TO THE MOBILE HOME, AS 15 INDICATED ABOVE. m 11/2' 6' CNTR-TO rr CNTR DIST. 6' CNTR-TO I1/2' CNTR DIST. - - Lu EDGE OF CONCRETE M 0 EDGE OF CONCRETE (LLu 1�� 1r, 0 ro� PLAN VIEW PLAN VIEW 3 x 3 x 1/8' COLUMN TWO (2) 3/6' DIA. THRU 3 x 3 x 1/8' COLUMN TWO (2) V PIA. THRU 3 x 3 x 1/8' COI (6063-T6) BOLTS W/ WASHERS (6063-T6) BOLTS W/ WASHERS (606346) ON EACH END ON EACH END 3' x 3' x V STRUCT. 3' x 3' x 3/6' STRUCT. ANGLE (3' LONG) ANGLE (3' LONG) e%06146), TYP ONE . (%061-T(o), TYP ONE ANGLE ON EA. 6IDE ANGLE ON EA. SIDE OF COLUMN OF COLUMN 3/8DIA. REDHEAD ? w 3/8' DIA. RED -HEAD w - TRIEOLTWEDGE W TRUBOLT WEDGE ANCHOR (TYP. 2 ANCHOR (TYP. 2 PLACES) PLACES) PLAN VIEW U X PLAN VIEW 3 x 3 x 1/8' COLUMN TWO (2) V2DIA. THRU (6063 T6) BOLTS W/ WASHERS ON EACH END 3' x 3' x 3/6' 5TRUCT. ANGLE (3' LONG) (%061-T6), TYP ONE ANGLE ON EA. SIDE OF COLUMN w i m L -TWO (2) N8' DIA. THRU BOLTS W/ WASHERS ON EACH ENE) 3' x 3' x 3/a' STRUCT. ANGLE (3' LONG) (%O(ol-T6), TYP ONE ANGLE ON EA. SIDE OF COLUMN r, ' I HAD z Q 8 D A. RED- E DIA. RED -HEAD w TRUBOLT WEDGE rRUBOLT WEDGE ANCHOR (TYP. 1 ANCHOR (TYP. 2 PLACES) �I ArFA ) SECTION VIEW SECTION VIEW SECTION VIEW #1 .. �4NCN01 �( T IL. #2 ANCHOR DETAIL. #3 CNTR-To-CNTR DISTANCE WELDED CONNECTION NOTES: I. ALL WI=LDED. COMPONENTS SNAt_I� 5E WELDED ON ALL OUTER FDGE5. GUSSTES SHALL RF WELDED ON BOTH 51DE5 OF EACH GUSSET. 2. ALL WELDS SHALL. BE 1/4', FULL -PENETRATION FILLET 41-IDS ISEE GEN. NOTE NUMBER 51X ON SHEET I FOR ADDITIONAL SPECIFICATIONS) N w U � -• - (K N -A' 16 a u EDGE OF CONCRETE LA n `f3 0 `� O PLAN VIEW 4 x 4 x 1/8' COLUMN 3 1 r O w TWO (2) /4 DIA. TNRiJ � � � 16063-T6I - n A BOLTS W/.WA5HER5 ON EACH END EDGE OF CONCRETE EDGE OF CONCRETE ^Q� 3'x3'x3/8'ONG) ANGLE (4' LONG) (+6061-T6), TYP ONE ANGLE ON EA. SIDE OF COLUMN z 3/4' PIA. REDHEAD Lu Lu TRU60LT WEDGE ANCHOR (TYP. 2 a, m PLACES) SECTION VIEW ANCHOR [DETAIL #5 PLAN VIEW 4x4x1/4'C (6063-T6) 1/2' DIA. RED -HEAL TRUI30LT WEDGE ANCHOR (TYP. 4 PLACES) PLAN VIEW 4 x 4 x 1/4' COLUMN f6063-T6) THICK PLATE MATL. s/a� pIA. REP -HEAP 3/8' THICK PLATE MATL. 61-T6) TRUBOLT WEDGE (6061-T6) ANCHOR (TYP. 4 PLACES) _ SECTION VIEW ANCHOR [DETAIL #� __--- z E tau SECTION VIEW ANCHOR DETAIL #i-- SECTION VIEW ,ANCHOR DETAIL #4 w .f ; ..4.w� $� fir/. ,�`• r - Y ra C�J .. PLAN VIEW 4 x 4 x I/4' COLUMN T (6063-T6) SECTION VIEW 3/6' THICK PLATE i 1ATL. (TYP. BASE PLATE AND GUSSETS) 16061-T(o) 3/4' DIA. RED -HEAD TRUBOLTWEDGE ANCHOR (TYP. 4 PLACES) �Wo w�CD B an w is u.recf� 0OLZe-m J z W cQ LU C9CO> wwo� s �m W � O ®m co z r F. Q OOe.0 U- e °=c� LnL J� '5 Lu a� c{K�, c- uj � �0 ® w00 cd Z 0 �1 CCU�77 a. U. i .032 BRAKE -FORMED RIDGE CAP W/ 012 TEKS (W/ 5/8' DIA, WASHERS) AT 12' O.C. FOR INSULATED ROOF AND INTO EACH RISER FOR PAN ROOF (TYR, CONTINUOUS), WITH MIN, OF 8-INCH LAP ONTO THE ROOF PANELS ON EACH SIDE 114' DIA. THRU BOLTS (WITH A WASHER ON BOTH ENDS) 9 8' O.C. (MAX) THROUGH BOTH HEADERS ON EACH SIDE OF RIDGE BEAM 23/s' x 3�i4' x 111/2' ALUM. ROOF HEADER WITH I x 2 x OS3 ANGLE SPACER (CONT.) AS NEEDED FOR GABLE PITCH WITH TWO ROWS OF 92 TEKS 9 IS' O.C. (EACH ROW TO BE STAGGERED) TYP. EACH SIDE OF RIDGE BEAM 3-INCH RISER PAN ROOF PANEL (TYP) INSULATED ALUM. 012 TEKS g 4' O.C. (3 PER ROOF PANEL (TYP) 12-INCH WIDE PAN) INTO BOTTOM OF PANS AND-`-` --- --- 012 TEKS im 12' O.C. (4 PER ONE (I) 012 TEK INTO THE 48-INCH PANEL) INTO TOP TOP OF EACH RISER (IF AND BOTTOM,OF PANELS ACCESS TO THE TOP OF (WHERE ACCESS TO TOP THE RISER IS LIMITED, #12 OR BOTTOM IS RESTRICTED, TEKS MUST BE INSTALLED 012 SHALL BE INSTALLED s 3' O.C. (4 PER 12-INCH a 6' O.C. IN ONE SURFACE -WIDE PAN IN THE BOTTOM OR THE OTHER) f NOTE: THE MAXIMUM PITCH FOR THIS CABLE ROOF INSTALLATION DESIGN SHALL BE 3 : 12 (140 SLOPE). 3' WIDE x 3' LONGER THAN CARRIER BEAM HEIGHT x 3/16' PLATE (EX.; FOR 8' TALL BEAM, PLATE SHALL BE3'xll') BOTTOM 3 INCHES OF PLAT THA LAPS ONTO SIDE OF 3 3 COLUMN SHALL HAVE FOt (4) N14 TEKS THRU THE PLA' AND INTO THE SIDE OF THE COLUMN BE 2' FOR I ! SHALL BE I' FOR NOTE: 1/4' THICK PLATE MAY BE CUT FROM THE SIDE WALLS OF A SCRAP PIECE OF 4 x 4 x 1/4' COLUMN ---SHALL 4 x 4 x 1/S' COLUMN :o 4 x 4 x 1/8 COLUMN r 4' WIDE x (HEIGHT SPECIFIED AT SIZE,. Fal NUMBER AND SIZE OF LEFT FOR DOUBLE CARRIER ___—NUMBER LTSAND THRU BOLTS 1Fd201 THRU-BOLTS (FROM Z � BEAMS) x 1/4' THICK PLATE, 'FODTER PAD KEY y FODTER PAD KEY q1 TYPICAL ONE ON EACH SIDE TABLE). BOLTS SHA� ,� TABLE). BOLTS SHALL I- = = = T OF COLUMN -TO -BEAM CON - HAVE WASHERS 0 4 P HAVE WASHERS ON BOTH ENDS AND PASS - - NECTION. BOTH ENDS AND " THROUGH THE NOT THROUGH BOTH SIDES i w � COLUMN, THE CARRI R OF THE NOTCHED THE NUMBER AND SIZE OF THRU BEAM AND THE 3/16':�j COLUMN CL m e BOLTS (AS SPECIFIED IN THE 'TOOTER PLATE ON THE OTHER SIDE AS WELL (TY�9� r 1 N N z w PAD KEY' TABLE) SHALL INSTALLED BOTH O = THROUGH H THE DOUBLE BEAM H AND THE COLUMN BELOW (IF=°- �-3 x 3 x 1/8, COLUMN > 3 x 3 x .125 COLUMN N C1 p t TABLE SPECIFIES FOUR 11/:' DIA. Rl BOLTS FOR CARRIER BEAM-TO- 3 x 3 COLUMN WITH x 3 COLUMN WITH COLUMN CONNECTION, THERE MUST BE FOUR BOLTS THROUGH OFFSET NOTCH CENTER NOTCH THE BEAM AND FOUR BOLTS ' 4 x 4 x 1/8' COLUMN THROUGH THE COLUMN) (MINIMUM FOR DOUBLE .rs CARRIER BEAM) 4 x 4 COLUMN WITH DBL. Li CARRIER REAM STANDARD COLUMN TO - CARRIER 5EAM_CONNECTION DETAILS T)"PICAL GAF3LE ROOF DETAIL #12 TEK SCREWS W/ 5/8' DIA. NOTE: FOR INSTALLATION ON AWOOD -FRAMED HOST STRUCTURE, (MIN.) WASHER AT 3' O.C. (4 THE CARRIER BEAM SHALL BE POSITIONED SO THAT ONE OF THE PER 12-INCH WIDE PAN) TWO ANGLES (ON EITHER SIDE) ANCHOR INTO THE STUD -FRAMING 92 TEK SCREWS W/ 5/8' DIA. NOTE: WHEN INSTALLING A 3-INCH IN THE WALL OF THE HOST STRUCTURE. (MIND WASHER AT 3' O.C. (4 PER 12-INCH WIDE PAN) RISER PAN ROOF SYSTEM ON A 3-INCH RISER PAN SM.B.-TYPE CARRIER BEAM, THE _ ROOF•PANEL�(TYP) 012 TEKS SCREWS THAT ANCHOR i 3' x 3' x i4' THC. ANGLE (M6063-T6) CUT 8 INCHES LONG, LE ( ONE ON THE ROOF PANS TO THE TOP OF - EACH SIDE OF CARRIER BEAM 3-INCH RISER PAN ROOF PANEL (TYP) THE CARRIER BEAM MAY ALSO ACT AS THE STITCH SCREWS FOR SMB, TYPE CARRIER_ BEAM u TOP THE TOP F4NGE OF THE SM.B, (FROM CARR: BEAM TABLE) 3/8' DIA. THRU BOLTS (W/ WASHER TUBE -TYPE CARRIER BEAM (FROM CARR. BEAM TABLE) TYPE CARRIER BEAM VIEW E ON EACH . NECEND) TYP. TWO PER -a== 7 3-INCH R15ER PAN 3/8' DIA.-RED=HEAD-'LDT'-TAPCON 3-INCH RISER WITH S.M.B. BEAM WITH MIN. EMBED INTO C.B.S. WALL OF OF 11/4' (INTO ACTUAL BLOCK), TYP, WITH TUBE BEAM 1/4' TWO 3/6' LDT'S PER ANGLE (FOUR x 4' THROUGH BOLT, W/ FENDER TOTAL PER CONNECTION) WASHER ON TOP SIDE, TO BE INST- ALLED 6 8' O.C. (SIX PER 48-INCH 2' ;' O wm PANEL) THROUGH 2 x 3 ANGLE 1/4' x 4' LAG SCREW W/ FENDER INSULATED ALUM. - WASHER (HOLE TO BE PILOT- ROOF PANEL (TYP) -' TYPICAL CARRIER BEAM DRILLED WITH A 5/32' BIT), TO 'z� u I D ARRIER '' BE INSTALLED 'a 6' O.C. (SIX LAGS PER 48-INCH WIDE PANEL) 2 x 3 x 1/8' ANGLE (CONT.) WITH ®16' O.C. F F_ BEAM TABLE) VIEW �c u TWO ROWS OF �4 TEKS INSULATED ALUM. (MAX.), EACH ROW SHALL BE ' ` — — IF CARRIER BEAM IS LESS rd ROOF PANEL (TYP) STAGGERED SO THERE IS A TEK SMB, TYPE CARRIER BEAM SCREWS EVEF2Y 8 INCHES (FROM CARR BEAM TABLE) to THAN 8 INCHES IN HEIGHT, - i O ANGLES MAY BE TRIMMED OFF AT ANGLE (AS SHOWN) TUBE -TYPE CARRIER BEAM (FROM GARB BEAM TABLE) NOTE: THE PILOT DRILL AND LAG SCREW (W/ FENDER WASHER) ATTACHMENT NOTE: THE 2 x 2 CONT. ANGLE ATTACHMENT MAY BE USED MAY BE USED FOR SM.B.-TYPE CARRIER BEAMS THAT ARE 2 x 8 AND -}- CARRIER f3EAM e I O ` HOST STRUCTURE WITH THE TUBE -TYPE CARRIER BEAM, IF THE CONTRACTOR CHOOSES TO UTILIZE THAT TYPE OF INSTALLATION. LARGER ONLY (SM.B: TYPE CARRIER BEAMS 2 x l AND SMALLER MUST UTILIZE THE 2 x 3 ANGLE ATTACHMENT). /� TYPICAL CONNECTION [DETAIL NSULATED ROOF PANEL INSULATED ROOF PANEL WITH TUBE BEAM WITH S.M.B. 51FAM ALUMINUM ROOF - TO -_ CARRIER 51HAM CONNECTION DETAIL - -` 5PECIAL DE51GN NOTE: THE LOAD CAPACITY FOR THIS 'CARRIER BEAM -TO -HOST STRUCTURE' CONNECTION DETAIL IS 3,000 LBS (SHEAR). WHEN A JOB SITE CONDITION CALLS FOR A CARRIER BEAM (EITHER FLAT ROOF OR GABLE ROOF) TO ATTACH TO A HOST STRUCTURE (OTHER THAN FOURTH WALL, WHERE THE LOAD WILL BE PREDOMINANTLY SUPPORTED BY THE VERTICAL COLUMNS), THE ENGINEER OF RECORD MUST REVIEW THE SITE -SPECIFIC PLAN FOR PLACEMENT OF SUPPORT COLUMNS, TO ENSURE THAT THE TRIBUTARY AREA LOAD ON THE END OF THE CARRIER BEAM(S) DOES NOT EXCEED THIS SPECIFIED LOAD CAPACITY _ - ps CD 9! z FE 4 p-_ W ur Lu COU