Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY: Date:10, Fee Due: Ee , c_z3 Receipt# 3Voco Permit # <5�1 mlo -., cam. -ALL INFO. MUST BE COMPLETE & FILLED IN T BE ACCEPTED tT St. Lucie County Building and Z Nam 2300 Virginia Avenue o . SCANNED Ft. Pierce, FL 34982-5652 -- -- SY 772-462-1553 ® C • �d s L�- St. Lucie County P*VA �iu,�ey APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: `SD I.q Pt1EIQ Tt 4 6C. "64715a = - •` "' `' 2. S/D' N WE::SPA VP5# LABS ITE PLAN NAME; �pl,� r1 la 'CA L-4 h V 4 I aA P 3. PROPERTY TAX ID #: `' ' - ' - - - ' 1301 - 1 1 '" 0001.-00D11 4. LEGAL DESCRIPTION (attach extra sheets if necessary); h q F_ 1. / 2. 37-3. 01 (01.324-24g1;414AD1) 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. NO. NO. 9. PARCEL SIZE: ACRES/SQ FT. 70 •J�� �L-OT-DIMENSIONS //0 'r p,16 i 10. SETBACKS=(ACTUAL) FRONT- BACK: RIGHT SIDE: ° LEFTzSIDE: 21 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIA E BOXES FOR EA H AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION SCREEN ROOM ❑ NEW KI EXISTING QL X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X - - ❑ SHED ❑ NEW ❑ EXISTING X _ ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE - Linear feet ❑ ROOF SYSTEM OVER EXISTING ACCESSARY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X TOTAL SQUARE FEET OF CONSTRUCTION oZ GY 12. VALUE OF CONSTRUCTION: $ /,3 0 �YS � The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with -similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Reu12/11/06ding OWNER INFORMATI NAME: .Lt /'. 7-A, s .rn it S ADDRESS: S a i- A P L-fe-x Td A a c uog Tcr- sAA AWAY / A-/arg CITY: rewr p loR- car STATE: fL ZIP PHONE (DAYTIME): rip,? -- 3 Ao r email: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM T THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER:• G3 y U M 4- S U I L©/,v C7 G ©r2 �:• ADDRESS: -L o2 g'o'e/ . '.S t..3 / .7 ? AjD A wr- CITY: A4 / ,4 „l / - STATE: /G ZIP PHONE (DAYTIME):l CONTRACTOR;.INFORMATI;ON•. . STATE OF FLORIDA REG./CERT #: G'aG / 2 f',3n t _ , ST. LUCIE COUNTY-CERT #: � BUSINESS NAME: W 4 L /< ,er2 J u i G Ab ar R-C QUALIFIER- S NAME: lo-'ru /V - (i Gti ,4 L IrCZnk! ADDRESS: 6 /3 l,•> ! M -� O w I Vc", CITY: $ I$ 5 7 /�1 STATE: ZIP PHONE (DAYTIME): (771) 3G %4 FAX NO-17#2-6-9/ - bOYO email:10riJ Y46 Q AOG . 1 ir? ARCHIT/ENGINEER: ` '5 TC-V►a IV ej. w oD 6, J' 3VS Q g ADDRESS: Q,! utrA^Ii0ki".Ve CITY: Jb,, A 7- e. v c I or STATE: ' /%L ZIP 3 Y 5 ,S-3 PHONE (DAYTIME): NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS r All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. '711 2 sets of color photos for all storm damaged. areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) ----- ---- --------- h -- -------- -------- OFFICE USE ONLY - ; ZONING Y SECTION 0 1 TOWNSHIP RANGE n `3OI L MAP NO. 13 KI Additional Yes ZONING -PU p LAND USE 9,U LOT CVG % Permits no REPORT CODE Gj L� BIMS FEE $ MISC FEES $ TOTAL FEES BiJILDING_ & ZONING =REVIEW -vz REVIEWS ZONING ZONING PLANS MISC. VEGETATION Value of Construction using REVIEWED BY EXAMING ICC Table DATE 10-2b-u�1 1 $ COMPLETE 1� 1 ,J PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: ❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Zones. (1) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guidel, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, section 2002. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self -catching gates with picket spacing. (2) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (3) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (4) SUNROOMS (as defined in R202 or FBCf202.1) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100 IN ACCORDANCE WITH FBC 2002.6 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The, designer or engineer will state=on>all Plans, which Category of Design [3.1.2] will be: used, inclusive"of the definition:;;: (2) If designing -a Category 4:or Category., .structure, as defined in the current Edition of 3.1.2.4 aiid 3.1.2.5; proper enetgy'. calculations and long form equipment;sizing calculations shall be required, pursuant to Chapter.13 of the current State of :. Florida Building Code. (5) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4t1i wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. q CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor / Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is. accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and IIVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceed the footprint of the structure that was in existence prior to removal by the storms. OWNER/CONTRACTOR SIGNATURE STATE OF FL �% COUNTY OFb� The foregoing instrument w acknowledged b6fore t 's f . 'day oAZjLJJ , 20� by who is personally known to me or -who has produced __1 as identification. Signature M,IIIII DARLENE A. SAURLE ;= MY COMMISSION # DO 499302 EXPIRES: December 13 2009 �e IMPORTANT NOTICES: _'wg z_- V�,� C014fRACTOR SIGNATURE The foregoing mi sntrument w acknowledged ore me is/7' ay o , 20-7,by who is personally known to me or who has produced identification. i %Sigi.(f Notary (SE NM�� DARLEW A. SAURLE r.a iv' MY COMMISSION # DO 499302 EXPIRES: December 13, 2009 1 p� R'V� Boodednm Notary PubtiicUnderwriters • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL -BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. r ` Code Compliance Division 2300 Virginia -Avenue Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stl ucleco. gov/ce INSPECTION CARD Permit #: SLC- 0710-0285 Conf #: 656 Type: MA/RV Addition Existing Concrete Issued 11/07/2007 Status: FIN Double Fee: No Job Location 50 LA PUERTA DEL NORTE City: FORT PIERCE Jurisdiction: St. Lucie County Lot: Block: Parcel: 1301-113-0001-000/1 Subdiv: Flood: Elev: Flood Map: Job Description: REBUILD OF 12 X 22 SCREENROOM TO BE PLACED ON EXISTING RAISED SLAB Setbacks Left: 31.00 Right Inspection Notes: Front 55.00 Rear, 30.00 Contractor GLENN E. WALKER WALKER BUILDERS INC (772) 473-3116 P O BOX 280035 SEBASTIAN, FL 32978 Property Owner WYNNE BUILDING CORP (772) 878-5513 12804 SW 122ND AVE MIAMI, FL 33186-6203 Tenant MR THOMAS (315) 408-3801 50 LA PUERTA DEL NORTE FORT PIERCE, FL 34946 SUB -PERMITS Permit # Status PT Cert # DBA Owner / Builder Job Description 0710-0285-01 FIN EP 19326 ADVANCED ELECTRICAL SY! INSPECTIONS - For Requests, Call: (772) 462-1261 Permit # Code Description Pdority Date Sched. Res Description Inspector Date Insp. 0710-028E 157 Roof - Composite/Pan Atti 1 12/05/2007 90 Approved Van Whitaker 12/05/2007 null Resulted: Wed Dec 5 12:41:17 EST 2007 0710-028E 238 Electric Rough 1 12/05/2007 90 Approved Van Whitaker 12/05/2007 1214/07 incall schedule with mark/ contr. bac Resulted: Wed Dec 5 12:41:38 EST 2007 0710-028E 904 Fastners 1 12/05/2007 90 Approved Van Whitaker 12/05/2007 null Resulted: Wed Dec 5 12:40:27 EST 2007 0710-028E 995 Fourth Wall, Beam, Knee 1 1 12/05/2007 90 Approved Van Whitaker 12/05/2007 null Resulted: Wed Dec 5 12:40:51 EST 2007 0710-028E 280 Electric Final 2 12/05/2007 90 Approved Van Whitaker 12/05/2007 0710-028E 999 Final Inspection 2 99 Final Approval Van Whitaker 12/05/2007 Permit Nun 0710-0285 Building J Code Compliance Division Receipt 2300 Virginia Avenue Ft, Pierce, Fl- 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stl ucieco.gov/ce Date: 07 November 2007 ;•., Receipt #: • 0000058635 Job Address: 50 LA PUERTA DEL NORTE -Permit Number: SLC- 0710-0285 Received By: dpelton G .. Amount: $133.90 Paid With: vs :redit Card Number: XXXXXXXXXXXX1902 Check Number: Paid By: WALKER BUILDERS INC Sign: 4~_ Code Compliance Division 2300 Virginia Avenue Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce BUILDING PERMIT Page 1 Issued: 11/05/2007 Conf #; 906 Permit #: SLC- 0710-0300 Job Location: 3855 S US HWY 1 City: FORT PIERCE Permit Type: County Permit Job Description: REPLACING THREE (3) SINGLE DOORS, WITH DOUBLE DOORS AND 4'X 7' HANDICAP RAMP WITH HANDRAIL Subdiv: Kellem's S/D Lot: 10 Block: Property Owner ST LUCIE COUNTY Setbacks Left: Number of Units: 1.00 Parcel: 2434-601-0046-000/8 2300 VIRGINIA AVE FORT PIERCE, FL 34982-5632 Minimum Floor Elevation: Job Value: $ 22,500.00 Right: Front: Rear: Zoning: Floors: 1 Buildings; ;1-' Square Footage: 0.00 Flood Map: Flood Zone: Elev: (>.i. Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official :; =;y 1 Date For Automated Inspections, Call,(7*4'62-1261 For Questions, Call (772) 462-2 ,77 St. Lucie County Land Development Code Section 11.05.01 (A)t(2}.estates; Building Permits shall expire and become null and void if work authorized by such Building Perrnifis not commenced, having called for and received a satisfactory inspection, within six (6) months from the -date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURTr- SAINT LUCIE COUNTY FILE # 3130301 OR Bl,-—,,,2901 PAGE 2848, Recorded 11/07/200',° 09:22 AM NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement Will be made to certain real property, and in accordance with Chapter 713, Florida Statues the following information is provided in the Notice of Commencement 1. DEScwnoN OF PRoPER7Y (Legal description and street address, if available) TAX FOLIO NUMBER: l &I -96 D610 00 1 SUBDIVISION 2. GENERAL DESCRHMON OFM?tOy,[�}MNT i 4-I'd-0 .2 Z�X` 12 At—dj &4,"-VL f.,owM 2".4 3. OWNER INFORMATION: LName CeI a_s ♦ t T w uw/as T ir..H .t5 b.Add.-rV 4A Pu-rR77 erL. ■real ,--40A NKa 44*0$ = e e, mucot in propat)•_ 21 Ff- d. Name ad address of face simple titleholder (dcd=than Owner) 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: 41AcK/+Q v/ L46+lQ S TN c Ro. SOX s- Ar. ru t, -a 77 S /-le 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: f7;- Fite v -• �-2 a _ eoi.ia^ 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: , 8. In addition to himself or herself Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1) (b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is specked): — 20_ Signature of O ner or V ' Owner's Authorized Officer/Director/Partner/Manager �'iG!//V StateVo�� County of �/ s �F FE Yw N r+t The foregoing instrument was acknowledgged before me this •7 day of DG�o btsr� 20QZ /= D r1l A 4-� C `t-horn 8 By A'a a t' „ t3 L I-K e P.s 4-,c eg as /l !rl U ex 1 (name ofpersoV (type of authority,... e.g. officer, trustee, attorney in fact) For goW,4nD C. Tito .3o.q✓1»ss y y-jr (name of party on behalf of whom instrument was executed) TV _Personally known oc pr^" a. _ _ r " •••rag 9iinf'a nt r t?LJ �. l�y,.�� &tery Public in the State of New Ytik n (Signature of Notary Public) Qualified In Jeffersonon Co� �ommtuion osPiros:.i � Under Penalties of perjury, I declare that l have read the foregoing and that the facts in it are true to the best of my knowledge and belief(Section 92.525, Florida Statutes). B ^ Slgnsture(s� Owne s wner(s)' ed 0lreer/Dir t / Partner/Manager who signed above: �` d� By ��� �e7ila0 R,v.01149.07 (S.Reoarding) STATE OF FLO,RIOA ST L.UCIE COUNTY ' \� � OUPjTyCt THIS TO CERTIFY THAT THIS IS A 91� TRUE AN[) COR�j4CT COPY OF THE ORIOif:!AI_ ED t FRY, RERK . N ,�, B.y' t, Do ut°$�w PP Y�,® /FcouM�r.t� Bib ' C - O N St. Lucie County Building -& Zoning 2300 Virginia Ave Fort Pierce, FL 34982 BUILDING PERMIT SUB -CONTRACTOR SUMMARY. vIOC� 1 �crP.0 ��ef S . a riG . will be using the following sub -contractors for'the (Company/Individual Name) project located at _�9_0 Xet (Street address or Property Tax ID #) It is understood that if there is any change of status regarding the participation of any of the sub -contractors listed below, I will immediately advise "the Building and Zoning Department of St. Lucie County. Trade, Name of Company/Contractor St. Lucie County/ State of Florida License Number Electrical JI Plumbing HVAC/ Mechanical Roofing Gas PERMIT ISSUE DATE: NUMBER: �J ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT . F�OR1�P •. BUILDING PERMIT SUB -CONTRACTOR AGREEMENT ° St. Lucie County Contractor Certification Number: J State of Florida Certification Number (if applicable): _ CC 3l3y have agreed to be the (Company Name/Individual Pame) pcc�riCM1 sub -contractor for Wa/ker (Type of Trade) (Primary Contractor for the project located at ,5-0 Zg (Project Street Address or Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIGNATURES ARE REQUIRED t' SIGNA PRINT NAME DAT Business Name: Address: ao.2 Q 0 City/State/Zip: " c it i _Phone: %'72' 7 i O—..; y® `7 OFFICE USE ONLY: email: Oo e;i 6e, t(yau7w , Property Appraiser - St.j ucie County, FL Wynne Building Corp Record: 1 of 5 Property Identification Site Address: 14 LA VILLA WAY Sec/Town/Range: 01 :34S :39E Map ID: 13/01N Zoning: PUD Ownership and Mailing Owner: Wynne Building Corp Address: 12804 SW 122nd Ave Miami FL 33186-6203 PROPERTY RECORD CARD <<Prev Next>>, Spec.Assmnt Page lofl Taxes Exemptions Permits Home Print �VOCIE 0 ParcellD: �� Gy Account * 317 Land Use: PRKG/MOBILE City/Cnty: ST. LUCIE COUNTY i '§� Legal Description 1 34 39 E 1/2 (323.99 AC) (OR 324-2491: 414-907) Sales Information Assessment Final Total Land and Building Date Price Code Deed Book/Page 2007 FV: 29805700 Land Value: 25680000 Acres: 323.99 1/1/1980 950000 00 CV 0324 / 2491 Assessed: 29805700 Building Value: 4125700 11/1/1978 390000 00 CV 0307 / 1544 Ag.Credit: 0 Finished Area: 21783 SgFt Exempt: 0 Taxable: 29805700 Taxes: 562934.28 BUILDING INFORMATION No imlage A�rail a :• le Exterior Features View: RoofCover: - RoofStruct: ExtType: MHPK - MH Parks YearBlt: 1982 Frame: Grade: C - C EffYrBlt: 1982 PrimeWall: StoryHght: 0010 - 1 Story No.Units: 1284 SecWall: - Interior Features BedRooms: 1284 Electric: - PrmintWall: - FullBath: 0 HeatType: AvgHt/FI: 1/2Bath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth CNC2 " CONCRETE LOW Y 1 7200 AV AV 1982 1 2800-PRKG/MOBILE 176 -Site 1284 CNC2 " CONCRETE LOW Y 1 5952 AV AV 1982 y MIN.K REO. FEW - CHAINLINK 10 Y 1 200 AV AV 1982 FEN4 " CHAINLINK 4' Y 1 160 AV AV 1982 r FEN6 'CHAINLINK 6' Y 1 665 AV AV 1982 S S " ASP1 HIGH Y 1 199380 AV AV 1982 �� 1ASP1 !arCSAV r1t) "COM POOL AVG Y 1 2720 AV AV 1982 PA01 POOL DK-AVG Y 1 6304 AV AV 1982 , 1�-1i1CURB "CEMENT CURB Y 1 695 AV AV 1982, ASP1 " ASP1 HIGH Y 1 360000 AV AV 1982 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http:rrwww.pasic.org/prC.asp?prClid=130111100010005 10/ 0007 Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stlucieco.gov/ce Date: 25 October 2007 Receipt #: 0000058386 Job Address: 50 LA PUERTA DEL NORTE -ermit Number: SLC- 0710-0285 Received By: goycochb Amount: $50.00 Paid With: CK �redit Card Number: Check Number: 1264 Paid By: WALKER BUILDERS INC Sign: . - � � �r •�-. - � -- �^ T- —_---� rs��,--sue• i 11��._, \\ j,•• t F ®0 POUT A 1 VED t CRAelwCaLTOp� - i op C y r ile ;; a., ,A '� -� ,,•�.• .. .a .:,�. MIN, SETBACKABQ. ' ..:r:. "FRONT SIDES ._' - �;,;��' . CNR SIDES ••.:: , -.. - _....,....,.. - ... �'� - . . -.�_.. ...._.._ �. REAR ZNG TECH. t e. General dotes and Specifications. I. Construction shall be in accordence with F5C 2004, to include 2006 Supplements, Chapters 16, 20 and applicable provisions of ASCE 1-95 2. The Contractor, Sub -Contractor, Supplier, etc shall verify all dimensions, jobsite conditions, specifications, etc. 3. Design Loads: Wind Design Loads = 40 PSF Wind velocity = 140 mph (3 sec gust) Zone: 5 Importance Factor Ohl Building Classification: 1 4. Concrete slab to be a minimum of 4" nominal thickness and have a compressive strength of fc+2500psi. 5. Extruded aluminum members shall have a minimum thickness of .040 inch and 606346 alloy. 6. Composite panel skins to be of aluminum alloy 3105-WI5 or 3105-H25. i. Sun -Room is designed as a CATEGORY I (3.12.) structure: A roof or covering of an outdoor space. The openings are permitted to be enclosed with insect screening or 0.5 mm (20 mil maximum thickness plastic film. The space Is defined as non -habitable and unconditioned. 8. Minimum edge distance for concrete anchors = Diameter of anchor s 5. (ex. - 1/41' tapcon • 5 = 1 1/4" minimum edge distance) THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. Thomas Residence 50 La Porta Del Norte Fort Pierce, FL 5pan i sh Lakes Country Club Im P OPY ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCE REVIEWED BY DATE 11 6 o 7 PLANS AND PERMIT MU T E KEPT ON JOB OR NO INSPECTION WILL BE MADE. (0-71C-OoZ8S Steven G. Wood, P.E. FL P.E. # 34398 950 Sultan Drive Port St Lucie, FL 34953 Contractor: Walker Builders, Inc. ON ;I�IJ 10'-51/2"(Typ) \Line of 3x0D32" I Ibs yp Composite panels 21'-S" Ian View Cs G a Ralsed Conn Deck a o. ' Rear/4th Wali Front/Main Wall 1 i;y( tP2�w ®TCalculations (0'41 f 33'-6" = 223sf 240 - .65 = 145sf (min. Allowed) Actual Opening = 154s f � l Keck ® 3x3x0M2 Post 2x2x0.044 Hollow G UU045 Hollow Q 2x4x01d50 Hollow E 2x5x0.062 Hollow Q UUO.045 Cx9 2x6x.050 SM5 H Ix2 0.5. Switch 1-41 Exterior Light Fixture Steven G. Wood, Fe 343W /LQ 7 S50 Sultan Drive Fort�L�LLucfe, FL 144" SMS with 125" 144" SMS with 1.25" 3x3 Corner m neoprene washers or neoprene washers or Post FIL ckQ COPY cover washers w/ caulk cover washers w/ caulk 0 > S ace 9" O.C. space 6" O.C. ix2 O.B. e 0 «10x2" SMS � u *12x0.15" SMS a 18" OC Panel Panel 2) per le iZto S p C R 3x2 HeaderA�\9) IO�x3'� SMS 3x2 Headerlfff\2) 010x2" SMS 1.511x1.5" Anale 2x4 12xO.15" SMS 2) bar leo. 5unroom header/post attachment. Main Wail. 012xO.15" SMS I 1.5"x1.5" Angle oar 2) lea. 025" Tapcon w/ 2315" min embed. I ea angle, .f A ll ^ - f.-I I J Hollow" Post to Foundation 1.511x1.5" Angle �� I\ VxO.15" SMS n 2) per lea. 2x3 post 5unroom header/post attachment. Side Wall, I" Angle, Top and Bottom of Girt or Comparable Zeceivina Channel *10 x OBO" SMS, 2 ea leg of angle or receiving channel Chair-ra i 1/Girt Detcli l 3x3 post w/ lx2 attachment Ln P Kickolate channel V f10x0.15" SMS 12" O C. Kickplate Attachment Scale: 2" - P � r z � m � U O Aber o uPL ` J 0. LL s Kickplate - Edges IS f Fully captured in channel. O u 0 U Steven G. Wood, IbE P8"�4398 2L /D1/3,0 7 Sultan Drive Port St. Luci At 2) 025 x 35' Thru BoltsMuts / Notch Post as neccesaru Beam, inhere 1.5" Receiver Channel w/ 4)12x0.i5" SMS per side, (o) interior to Bost Seam to Post Connection 1.5x3x0.125" "U" Insert or external An Iles 2) 025 x 3.5" Thru 4) 025" Tap -Con BOIts/Nuts. Anchors w/ 2315 min. Embedment. 3" Post to Foundation For Riser Pans use 4) 012x0.i5" SMS w/ 0.15" neoprene washers. Option - Cover stnd. washers w/ For Composite Panels use "10x4" SMS with 125" neoprene washers or cover washers w/ caulk Sr a ce 12" O.G. �" Composite Panel or Riser Pan Panel or Riser Pan to Dearing Seam 010 x OBO" SMS, 2 ea leg of angle or lx2 to Wdr attachment ib" Receiver (o)"12x0.15" Flashing returned under drip. IF no drip present, bed and seal 12 x 0.15" Main Flashing Detail Beam Knee 3) "12 x 0.15" SMS per side or 2) O2 Bolts/nuts IS" Minimum min. All Knee 5race Connections 950 a bl � A tL p f1go cq Cc f� z p R LPL u- - U rp3p J O CL Q �QQ Steven G. Wood, P°E PE" �43W 7 n Drive Port St Lucia