HomeMy WebLinkAboutSUBMITTED PAPERS_3r I I I TECH DRIVE, SANFORD, FL 32771 Fire Sprinklers. lnc. (407) 328-3000 FAX (407) 328-3001 FIRE SPRINKLER SYSTEM �- HYDRAULIC CALCULATIONS I_ f - AND PRODUCT DATA - SUBMITTAL PROJECT: VINCENT DISISTO TRUST LOT 22 BLOCK B COMMERCIAL CIRCLE - KINGS HIGHWAY INDUSTRIAL PARK -- ST. LUCIE COUNTY, FL FROM: DELTA FIRE SPRINKLERS INC. - ' 111 TECH DRIVE SANFORD, FL. 32771 i I`- DATE: AUGUST 3, 2006 AUG 0 3 2006 EDGARDO CORDOBA, P.E. 13649 TETHERLINE TRAIL ORLANDO, FL.32837 LICENSE NO. 57991 � t �f Commercial • Residential • Industrial Design • Fabrication 9 Installation 9 Maintenance 9 Inspection I �I . _ . Fire Protection by Computer Design DELTA FIRE SPRINKLERS 111 TECH DRIVE SANFORD, FL 32771 407-328-3000 Job Name VINCENT DISISTO TRUST Building WAREHOUSE Location ST. LUCIE COUNTY, FLORIDA System 1 Contract T.B.A. Data File DISISTO1.WX1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 DELTA FIRE SPRINKLERS Page 1 VINCENT DISISTO TRUST Date 07-28-06 Hydraulic Design Information Sheet Name - VINCENT DISISTO TRUST Date - 07-28-06 Location - ST. LUCIE COUNTY, FLORIDA Building - WAREHOUSE System No. - 1 Contractor - DELTA FIRE SPRINKLERS Contract No. - T.B.A. Calculated By - E.L.C. Drawing No. - FP-2 tConstruction: ( ) Combustible (X) Non -Combustible Ceiling Height - VAR Occupancy - WAREHOUSE - ORDINARY HAZARD - CLASS III COMMODITY S� - (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C (X) Figure 12.2.2.1.5.2 Curve CLASS III S Other FIG. 12.2.2.1.5.3 USING 18' STORAGE HEIGHT T - Specific Ruling Made By Date E j M Area of Sprinkler Operation - 2000 System Type Sprinkler/Nozzle Density - 0.185 (X) Wet Make GLOBE D _ Area Per Sprinkler - 128.3 ( ) Dry Model GL8118 E Elevation at Highest Outlet - 19.5' ( ) Deluge Size 3/4" S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 8.0 `-' I Rack Sprinkler Allowance - ( ) Other Temp.Rat.286°F G Hose Allowance - Outside - 50q' i N Note DENSITY = 0.215 x 0.86 = 0.185 Calculation Flow Required - 898.813 Press Required - 33.913 at City Summary C-Factor Used: 120 Overhead 150 . Underground W Water Flow Test: Pump Data: Tank or Reservoir: ! A Date of Test - 10-14-05 Cap. - T Time of Test - 10:00 AM Rated Cap.- Elev.- E Static Press - 70 @ Press - R Residual Press - 37 Elev. - Well _ Flow - 1000 Proof Flow S Elevation - 2 U P Location - COMMERCIAL CIRCLE, HYDRANTS H73 AND H75 P L Source of Information - FORT PIERCE UTILITIES AUTHORITY Y C Commodity ANY CLASS I, II OR III Class Location O Stor.age.Ht.. 18'-Max. - Area Aisle W. M Storage Method: Solid Piled 100 % Palletized 100 % Rack NO M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Enca P� S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non 1' A. ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling ,-A Longitudinal Transverse G` E Horizontal Barriers Provided: - Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ..,s�✓e (�-- - - -- -,---- —_- _ -- - - - - - - DELTA FIRE SPRINKLERS 1 t - Page. 2 7 VINCENT DISISTO TRUST Bate 07-28-06 City Water Supply: Demand: C1 - Static Pressure : 70 D1 - Elevation 7.579 C2 - Residual Pressure: 37 D2 - System Flow 398.813 C2 - Residual Flow 1000 D2 - System Pressure 33.913 Hose ( Adj City ) Hose ( Demand) 500 D3 - System Demand 898.813 Safety Margin 8.997 150 140 130 P 120 R 110 E 100 90 S 80 S 70 C1 U 60 R 50 E 40 30 20 D3 10 D1 100 200 300 400 500 600 700 800 900 FLOW ( N " 1.85 ) C2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 DELTA FIRE SPRINKLERS r U Page 3 VINCENT DISISTO TRUST Date , 07-28-06 Fitting Legend Abbrev. Name % Y4 1 1% 1'/z 2 2'% 3 3'/z 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90' Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 _ Pressure / Flow Summary - STANDARD DELTA FIRE SPRINKLERS Page 4 VINCENT DISISTO TRUST Date 07-28-06 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. 1 19.5 8 2 8.8 na 23.74 0.185 128.3 7.0 19.5 8 3 9.0 na 24.01 0.185 128.3 7.0 19.5 8 4 - 9.74 na 24.97 0.185 128.3 7.0 19.5 8 5 11.34 na 26.94 0.185 128.3 7.0 19.5 8 6 - 19.5 8.81 na 23.74 0.185 128.3 7.0 8 7 19.5 8 9.01 na 24.01 0.185 128.3 7.0 8 19.5 8 9.74 na 24.97 0.185 128.3 7.0 9. 19.5 8 11.34 na 26.94 0.185 128.3 7.0 10 19.5 8 8.81 na 23.75 0.185 128.3 7.0 11 19.5 8 9.02 na 24.02 0.185 128.3 7.0 12 19.5 8 9.75 na 24.98 0.185 128.3 7.0 13 19.5 8 11.35 na 26.95 0.185 128.3 7.0 14 19.5 8 8.83 na 23.77 0.185 128.3 7.0 15 19.5 8 9.03 na 24.04 0.185 128.3 7.0 16 19.5 8 9.77 na 25.01 0.185 128.3 7.0 ' R1 17.83 11.37 na 26.98 0.185 128.3 7.0 R2 - 17.83 14.97 14.98 na na R3 17.83 14.99 na R4 17.83 15.02 na M1 15.33 17.16 na M2 15.33 17.16 na M3 15.33 ! 17.18 na M4 15.33 17.21 na TR 15.33 18.98 na BR 1•0 25.41 na UG1 -3.0 27.32 na UG2 -3.0 27.66 na UG3 -3.0 33.08 na UG4 -3.0 33.13 na 500.0 TST 2.0 i 33.91 na The maximum velocity is 13.65 and it occurs in the pipe between nodes 16 and R4 - Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams DELTA FIRE SPRINKLERS VINCENT DISISTO TRUST Page 5 Date 07-28-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. ..C., or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 - 23.74 1.728 0.0 12.830 8.803 K Factor = 8.00 to 120 0.0 0.0 0.0 2 23.74 0.0157 0.0 12.830 0.201 Vel = 3.25 2 24.00 1.728 0.0 12.830 9.004 K Factor = 8.00 tQ 120 0.0 0.0 0.0 3 ' 47.74 0.0573 0.0 12.830 0.735 Vel = 6.53 3 24.97 1.728 0.0 12.830 9.739 K Factor = 8.00 to 120 0.0 0.0 0.0 4 72.71 0.1246 0.0 12.830 1.599 Vel = 9.95 4 26.93 1.728 1 T 11.29 1.750 11.338 K Factor = 8.00 • to 120 0.0 11.290 0.723 R1 99.64 0.2234 0.0 13.040 2.913 Vel = 13.63 0.0 99.64 14.974 K Factor = 25.75 5 - 23.74 1.728 0.0 12.830 8.805 K Factor = 8.00 to 120 0.0 0.0 0.0 6 23.74 0.0157 0.0 12.830 0.202 Vel = 3.25 6 24.01 1:728 0.0 12.830 9.007 K Factor = 8.00 to 120 0.0 0.0 0.0 7 47.75 0.0572 0.0 12.830 0.734 Vel = 6.53 7 24.97 1.728 b.0 12.830 9.741 K Factor = 8.00 to 120 0.0 0.0 0.0 8 72.72 0.1247 0.0 12.830 1.600 Vel = 9.95 I -- 8 26.94 1.728 1 T 11.29 1.750 11.341 K Factor = 8.00 to 120 0.0 11.290 0.723 R2 99.66 0.2235 0.0 13.040 2.914 Vel = 13.63 0.0 99.66 14.978 K Factor = 2575 9 23.75 1.728 0.0 12.830 8.813 K Factor = 8.00 to 120 0.0 0.0 0.0 10 23.75 0.0157 0.0 12.830 0.202 Vel = 3.25 10 24.02 1.728 0.0 12.830 9.015 K Factor = 8.00 to 120 0.0 0.0 0.0 11 47.77 0.0574 0.0 12.830 0.736 Vel = 6.54 11 24.98 1.728 0.0 12.830 9.751 K Factor = 8.00 - to 120 -0.0 0.0 0.0 -- 12 72.75 0.1248 0.0 12.830 1.601 Vel = 9.95 12 26.96 1.728 1 T 11.29 1.750 11.352 K Factor = 8.00 to 120 0.0 11.290 0.723 - R3 99.71 0.2236 0.0 13.040 2.916 Vel = 13.64 0.0 99.71 14.991 K Factor = 25.75 - -13 - 23.77 1.728 0.0 12.830 8.831 K Factor = 8.00 to 120 0.0 0.0 0.0 14 23.77 0.0157 0.0 12.830 0.202 Vel = 3.25 14 24.05 1.728 0.0 12.830 9.033 K Factor = 8.00 to 120 0.0 0.0 0.0 15 47.82 0.0574 0.0 12.830 0.737 Vel = 6.54 15 25.00 1.728 0.0 12.830 9.770 K Factor = 8.00 to 120 0.0 0.0 0.0 _ 16 72.82 0.1250 0.0 12.830 1.604 Vel = 9.96 - Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard _ DELTA FIRE SPRINKLERS Page 6 VINCENT DISISTO TRUST Date 07-28-06 Hyd• Qa Dia. Fitting Pipe Pt Pt - Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 16 26.98 1.728 IT 11.29 1.750 11.374 K Factor = 8.00 - to 120 0.0 11.290 0.723 R4a 99.8 0.2241 0.0 13.040 2.922 Vel = 13.65 0.0 99.80 15.019 K Factor = 25.75 ' R1 99.64 2.203 IT 13.639 2.500 14.974 to 120 0.0 13.639 1.083 M4 99.64 0.0684 0.0 16.139 1.104 Vel = 8.39 0.0 99.64 17.161 K Factor = 24.05 R2 99.66 2.203 IT 13.639 2.500 14.978 r to • 120 0.0 13.639 1.083 l M2 99.66 0.0684 0.0 16.139 1.104 Vel = 8.39 0.0 " 99.66 _ 17.165 K Factor = 24.05 j R3 99.71 2.203 IT 13.639 2.500 14.991 to 120 0.0 13.639 1.083 M3 99.71 0.0685 0.0 16.139 1.105 Vel = 8.39 0.0 j 99.71. 17.179 K Factor = 24.06 R4 99.80 2.203 1 T 13.639 2.500 15.019 to 120 0.0 13.639 1.083 M4 99.8 0.0686 0.0 16.139 1.107 Vel = 8.40 0.0 99.80 17.209 K Factor = 24.06 j M1 99.64 6.357 0.0 10.000 17.161 - -' - to 120 0.0 0.0 0.0 M2 99.64 0.0004 0.0 10.000 0.004 Vel = 1.01 M2 99.66 6.357 0.0 10.000 17.165 " to 120 0.0 0.0 0.0 M3 199.3 0.0014 0.0 10.000 0.014 Vel = 2.01 M3 99.71 6.357 0.0 10.000 17.179 to 120 0.0 0.0 0.0 M4 299.01 0.0030 0.0 10.000 0.030 Vel = 3.02 M4 99.80 6.357 3E 52.808 292.920 17.209 to 120 0.0 52.808 0.0 TR 398.81 0.0051 0.0 345.728 1.766 Vel = 4.03 TR 0.0 6.357 1 B 12.573 14.330 18.975 _to 120 1 Z 17.603 30.176 6.206 BR • 398.81 0.0051 0.0 44.506 0.228 Vel = 4.03 BR 0.0 6.16 1 E 20.084 10.000 25.409 . to 140 1 F 10.042 30.126 1.732 -UG1 398.81 0.0045 0.0 40.126 0.180 Vel = 4.29 UG1 0.0 5.86 1F 8.947 58.000 27.321 to 150 0.0 8.946 0.0 _ UG2 398.81 0.0050 0.0 66.946 0.336 Vel = 4.74 UG2 0.0 6.16 4E 80.336 15.000 27.657 to 140 0.0 80.336 5.000 * Fixed loss = 5 - UG3 398.81 0.0045 0.0 95.336 0.427 Vel = 4.29 UG3 0.0 6.09 0.0 10.500 33.084 _ to 150 0.0 0.0 0.0 UG4 398.81 0.0042 0.0 10.500 0.044 Vel = 4.39 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard DELTA FIRE SPRINKLERS Page 7 VINCENT DISISTO TRUST Date 07-28-06 Hyd• Qa Dia. Fitting Pipe Pt Pt -- Ref. "CIS or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UG4 500.00 6.09 2E 43.166 63.500 33.128 Qa = 500 tQ 150 1 G 4.625 94.040 -2.166 TST 898.81 0.0187 1 T 46.249 157.540 2.951 Vel = 9.90 0.0 -- 898.81 33.913 K Factor = 154.34 i U Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ;JA DynamFlow@ High Strength Steel Pipe -- . The original high -strength lightwall sprinkler pipe with hydraulics superior to Schedule-10. L' yna-Flow pipe is the "original" high - strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. �llill:4dLil 0 a 11,161- 1 With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule-10, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down -sized within the system, thus increasing the potential for job cost savings. For complete Hazen - Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pes/ Mitt (21') WVLift (24') Wilt (25') In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 1'/4" 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 1'/i' 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2" 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 2'/z" 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3" 3.314 3.387 7.18 19 1,351 1' 1,544 1,608 80 84.2 5.0 10.69 19 613 ' 700 729 4" 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Coatings & Fabrication Specifications & Approvals Dyna-Flow products are coated with an environmentally approved and specially formulated modified -acrylic or water -based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. t'ycal Flow Control Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain -end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain -end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval infonnation. Dyna- Flow/Super Flo is now available "hot - dip" galvanized and has been specifically approved by FM for dry systems uses. • Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. • Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. • Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. • Fast cutting and welding, as well as easy roll grooving and end preparation. • Available in Factory roll grooved form for quicker shop turnaround. • Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. �1Q�III�� 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 7- m 11350 NorcoRd. • Philadelphia, PA 19154 (800 882-5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S2-3 s u. �`�� a� Yid' ��:'�.. < � � .. �� `��- .�.� rot�ec io u4U► -Fully Listed and FM Approved Sprinkler Pipe When you s eci chedule- - • y p fy S 10/Schedule 40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1'/4"- 8") pipe and Sch-40 (1 "- 2%") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe -Schedule-10/Schedule-40 product can be "hot -dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications ofASTM A-123. Superior Coating Our advanced formula mill coating of- fers a clean, durable surface. It is also paint -ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. American Made Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. ApprovalsSpecifications & Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture • Vibration Test Sch-40 Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Milt (21') Wt/Lift (24') Wl/Lift (25') In; mm In; mm Lbs/Ft Kg/m Lbs/Ft,Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1'/4" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1'/2" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21/2" 2.469 5.790 7.86 19 2,310 / 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10 Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WNLift (21') WVLiff (24') WVLift (25') In; mm In; mm Lbs/Ft,Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; 'Kg Lbs; Kg 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 1'/4" 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1'/2" 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 2'/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4". 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 twin Flow Control lam/ allied TUBE & CONDUIT @ <FM> UDC Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5-3 P. I. - F,,rrrnr�s A A'ri.Pon aJSfur Pier Prndune GROOVED COUPLINGS LISTED LISTED APPROVED FLEXIBLE NOMINAL SIZE (IN.) ACTUAL PIPE SIZE (IN.) COUPLING MAX. WORKING P.S.I. ALLOW. PIPE END SERAIN.) NUTSBOLTS DEFLECTION (INCH) DEG. PER PIPE OTY. SIZE COUPLING IN./FT. DIMENSIONS APPROX. WEIGHT EACH A B C 1 1/4 1.660 1000 0 -0.13 2 3/8x2 4 deg. -19' 0.90 4.20 2.75 1.78 1.40 1 1/2 1.900 1000 0 - 0.13 2 3/8x2 3 deg. - 46' 0.79 4.44 3.03. 1.78 1.48 2 2.375 1 1000 0 - 0.13 2 3/8x2 3 deg. - 01' 0.63 4.88 3.46 1.84 2.00 2 112 Z875 1 1000 0 - 0.13 2 3/8x2 2 deg. - 29' M52 5.50 4.00 1.84 2.25 3 3.500 1 1000 0 - 0.13 2 112x2 314 2 deg. - 03' 0.42 6.38 4.62 1.84 2.70 4 4.500 750 0 - 6.13 2 1/2x2 314 3 deg. -11' 0.66 7.68 5.81 2.06 4.42 5 5.563 700 0 - 0.25 2 5/8x3 1141 2 deg. - 35' 0.54 9.68 7.12 MIS 6.26 6 6.625 700 0 - 0.25 2 5/8x3 114 12 deg. - 10' 0.46 10.75 8.09 2.06 7.00 8 8.625 600 0 - 0.25 2 3/4x41/41 1 deg. - 40' 0.35 13.44 10.43 2.38 13.00 10 16.750 Soo 0 - 0.25 2 718x5 1 deg. -. 20' 0.28 16.70 12.88 2.625 21.50 12 12.750 1 400 0 - 0.25 2 7/8x5 I 1 deg. - 7' 0.23 16.50 14.89 2.625 27.36 NOTE: 1. Enclosed manufacturer's installation instructions must be used. 2. Consult Star Fittings working pressure submittal sheet GRS 1.3 for UUULC/FM ratings. B • t / RIGID NOMINAL SIZE (IN.) COUPLING ACTUAL PIPE SIZE (IN.) MAX. WORKING P.S.I. ALLOW. PIPE END SEP. (IN.) NUTS/BOLTS (INCH) QTY. SIZE DIMENSIONS APPROX. WEIGHT EACH A S C 1 114 1.660 750 0 - 0.13 2 3/8x2 4.20 2.55 1.70 1.48 1 1/2 1.900 750 0 - 0,13 2 3/8x2 4.44 2.81 1.70 1.66 2 2.375 750 0 - 0.13 2 3/8x2 4.88 3-28 1.76 1.94 2112 2.875 750 0 - 0.13 2 3/8x2 114 5.50 3.78 1.76 1.86 3 3.500 750 0 0.13 ..-F----.-... 2 3/8x21/4 6.38 4.40 1.76 2_ 4� 4 4.500 1 90 0 - 0.25 2 3/8x2 1/4 7.68 5.59 1.98 3.17 6 6.625 1 700 0 - 0.25 2 1/2x2 3/4 10.75 7.87 1.98 5.84 8 8.625 600 0 - 0.25 2 5/8x3 114 13.44 10.21 2.22 10.82 10 10.750 500 0 - 0.25 2 7/8x5 16.70 12.88 2.625 21.50 12 12.750 400 0 - 0.25 2 7/8x5 i 18.50 14.89 2,625 27,36 NOTE: 1. Enclosed manufacturer's installation instructions must be used. 2. Consult Star Fittings working pressure submittal sheet GRS 1.3 for UL/ULC/FM ratings. 2 FITTINGS C Lo 1-7 ------- f4 C GROOVED FITTINGS LISTED LISTED APPROVED 'NOMINAL SIZE (IN.), E-1 900 ELBOW CENTER To APPROX- WEIGHT END (IN.) EACH (48sj E-2 450 ELBOW CENTER TO APPROX. WEIGHT END (IN.) EACH(LBS.) E-3 22 1/20 ELBOW (sw) CENTER TO APPROX- END �jm) WEIGHT EACH(LBS.) E-4 11 1/40 ELBOW (sw) cENTthTO APPROX: END (IN.) WEIGHT EACH (LEIS.) E-9 DRAIN ELBOW (sw) CENTER TO END 11/4 2.75 1A 1.75 0.8 1.75 0.8 1.31 015 11/2 2.75 1.2 1.75 019 1.75 1.0 1.37 0.7 2 3.25 2.0 2,00 1.5 2.00 1.6 1.37 0.9 3.25 21/2 3.75 2.9 2.25 2.2 2.00 2.1 1.50 1.5 3.75 3 4.25 41.3 2.50 3.2 2.25 3.1 1.50 2.0 4.25 4 5.OD 8.7 3.00 5.7 2.87 5.4 1.75 3.3 5.00 5 5.50 111,9 3.25 8.2 2.88 7.8 2.00 5.0 6 6.50 18.2 3.50 11.0 3.12 8.3 2.00 6.5 6.50 8 7.75 32.2 4.25 20.4 3.87 17.9 2.00 10.0 7.75 10 9100 49-0 4.75 31.5 4.75 30-0 2.12 14.5 9.00 12 10.00 70.0 5.25 44.1 4.87 40.4 225 18.7 10.00 NOTE: Fittings may be ductile iron and/or segment -welded steel. Fitting pressure ratings conform to coupling rating. (SW) Segmentally welded steel. 4 p FITTINGS d Dhbirnr of k., Pip, Produm GROOVED FITTINGS LISTED LISTED APPROVED NOMINAL SIZE (IN,) CENTER APPROX. TEND WEIGHT EACH (IN.) (LBS.) NOMINAL SIZE (IN•) f 2 STD, T 3 w1T . D BR. APPROX. WEIGHT CENTER EACH TO END (LBS.) (IN.) NOMINAL SIZE (IN ) T2 STD. T-3 wITHD BR. APPROX. WEIGHT EACH (LBS.) CENTER TO END (IN.) CENTER TO END (IN.) CON -TER EN TO END (IN.) 11/4 2.75 1.7 2x2xl 3.25 3.25 2.6 6x6x5 6.50 6.50 28.0 11/2 2.75 1.8 2x2x11/2 3.25 3.25 2.7 8x8x2 7.75 7.75 37.5 2 3.25 2.9 2 1/2x2 i/2x2 3.75 3.76 4.4 8x8x3 7.75 7.75 ' 38.7 21/2 3.75 4.6 3x3x1 4.25 4.25 7.0 8x8x4 7.75 7.75 50.0 3 4.25 6.9 3x3x11/2 4.25 4.25 5.3 8x8x5 7.75 7.75 41.0 4 6.00 10.9 3x3x21/2 4.25 4.25 5.8 10x10x2 9.00 9.00 61.8 5 5.50 17.8 4x4x2 5.00 5.00 10.2 10x10x4 9.00 9.00 64.0 6 6.50 25.0 4x4x21/2 5.00 5.00 11.2 10x10x5 9.00 9.00 65.1 8 7.75 42.1 4x4x3 5.00 5.00 11.4 10x10x6 9.00 9.00 55.0 10 9.00 69.0 5x5x2 5.50 6.50 14.5 10x10x8 9.00 9.00 64.7 12 10.00 91.0 5x5x3 5.50 5.50 16.1 12xl2x3 10.00 10.00 84.9 - - - 5x5x4 5.50 5.50 17-9 12x12x4 10.00 10.00 85.8 l - - - 6x6x2 6.50 6.50 26.4 12x12x5 10.00 10.00 87.0 - - - 6x6x2112 6.50 i 6.50 26.5 12x12x6 10.00 10.00 88.3 - - - 6x6x3 6.50 6.50 26.5 12xl2x8 10.00 i 10.00 91.2 - - - 6x6x4 6.50 6.50 26.5 12x12x10 10.00 10.00 94.8 NOTE: Fittings may be ductile iron and/or segment -welded steel. Fitting pressure ratings conform to coupling rating. (SW) Segmentally welded steel. 5 F/TTINC7S .i!)fv=c/Sh. P.,P dvn E to 1--..... i NOMINAL WEIGHT 1 E TO E $12E (IN.) EACH (IN.) (LBS) 1 114 x 1 2.50 1.0 1 1/2z1 to 1 114 2.50 1.0 2x1 to 1 1/2 2.50 1.0 2 1/2xl to 2 2.50 1.5 3x1 to 2 112 2.50 1.5 3 1/2z1 to 3 2.50 2.0 4x1 to 3 1/2 3.00 3.0 5x1 to 4 3.50 5.0 60 to 5 4.00 6.5 8x1 to 6 5.00 8.0 10x1 to 8 6.00 16.0 12x1 to 10 7.00 26.i3 NOTE: Fittings may be ductile iron or segment -welded steel. 1 Fitting pressure ratings conform to coupling rating. (SW) Segmentally welded steel. .I . _ i CLeE� E,\ 4 9 0 U 7- GROOVED FITTINGS f' <�> LISTED LISTED APPROVED _. _..__. E Lo E NOMINAL E TO E WEIGHT SIZE (IN.) EACH (IN.) (LBS) 1 114 x 1 8.50 1.0 1 112x1 to 1 114 8.50 1.0 2x1 to 1 1/2 9.00 1.0 2 1/2x1 to 2 9.00 1.5 3x1 to 2 1/2 9.50 1.5 3 1/2x9 to 3 9.50 2.0, 4x1 to 3 1/2 10.00 3.0 5x1 to 4 11.00 5.0 6x1 to 6 11.50 6.5 8x1 to 6 12.00 8.0 10X1 tp 8 13.00 16.0 12x1 to.10 14.00 26.0 FIRE PROTECTION 1•• 900 ' ELBOW 450 ELBOW NOMINAL CENTERTO APPROX. APPROX. SIZE CENTER TO CENTER To APPROX. END (IN.) WEIGHT END (IN.) WEIGHT END (IN.) WEIGHT (IN.) EACH (LBS.) EACH (LBS.) EACH (LBS.) 1 2 2.75 1.50 2.00 1,29 2.75 2.27 2112 _ 3.00 2.14 2.25 2.00 3.00 3.30 I 3 3.38 3.60 2.50 3.06 3.38 5.04 4 4.00 5.78 3.00 4.89 4.00 7.86 6 5.50 11.76 3.50 9.59 5.50 17.73 8 6.81 21.10 4.25 15.40 6.94 29.00 t- GROOVED FLANGES & CAPS D FIMArGS (�� V <�> 01 .4Oi4o' gf.V.,Pip, P-d- LISTED LISTED APPROVED F-1 GROOVED FLANGE NOMINAL ACTUAL SIZE PIPE (IN.) SIZE MAX. WORKING P.S.I. ADAPTER DIMENSIONS APPROX. WEIGHT EA. (LBS.) # OF BOLTS BOLT SIZE (INCH) A B C 2 2.375 300 6.00 4.75 0.75 3.2 4 5/8x2 3/4 2 1/2 2.875 3 0 7.00 5.50 0.88 4.6 4 5/8x3 3 3.500 300 7.50 6.00 0.94 5.7 4 5/8x3 4* 4.500 300 9.00 7.50 1 0.95 7.9 8 5/8x3 6 6.625 300 11.00 9.50 1 1.00 10.0 8 3/4x31/2 8 8.625 300 13.50 11.75 1 1.125 15.7 8 3/4x3.112 10 10.75 300 16.60 14.25 1 1.19 18.4 12 7/8X4 12 1 12.75 300 19.00 17.00 1 1.25 28.0 12 7/8X4 NOTE: Please consult the flange installation information in this catalog. Bolts to be supplied by customer or contact your Star Fittings Distributor. F-2 FLANGE ■ ■ NOMINAL E TO E APPROX. SIZE WEIGHT (IN.) (INCH) EACH (LBS) 1 3.00 2.7 1 114 4.00 3.3 1 1/2 4.Ob 3.9 2 4.00 6.2 2 1/2 4.00 9.9 3 4.00 11.4 3 112 4.00 15.1 4 6.00 18.4 5 6.00 21.3 6 6.00 27.5 8 6.00 41.3 10 8.00 59.8 12 8.00 88.2 NOTE: Please consult the flange installation information in this catalog.Fitting pressure ratings conform to flange & coupling rating. Flange bolts to be supplied by customer or contact your Star Fittings Distributor. (SW) Segmentally welded steel. GROOVED CAP NOMINAL ACTUAL SIZE PIPE (IN.) SIZE (IN.) E TOE (INCH) WEIGHT WEIGHT EACH (LBS) 1 1/4 1.660 1.00 1 .365 1 1/2 1.900 1.00 .500 2 2.375 1.00 .680 I 2112 2.875 1.00 .960 3 3.500 1.00 1.38 4 4.500 1.06 2.36 6 6.625 1.06 I 4.59 8 8.625 1.19 s 7.77 10 10.75 1.25 j� 21.00 12 12.75 1.25 35.50 NOTE: Fittings may be ductile iron or segment -welded steel. Fitting pressure ratings conform to coupling rating. FITTINGS � d Pir•isinn elfSrnr!'+}7.-. Prndr�c� MECHANICAL TEES ��� kF M LISTED LISTED APPROVED THREADED NOMINAL SIZE • (IN.) HOLE DIA. + .1251-0.0 . NUTSIBOLTS CITY. SIZE BRANCH DIMENSIONS APPROX. WEIGHT EACH A B C D _ E 2x1 1.50 2 3/8x2 2.62 1.58 4.62 2.47 1.96 1.7 2 x 1 1/4 1.75 2 3/8x2 2.62 1.58 4.62 2.47 1.94 1.7 2x1 11 2 1.75 2 3/8x2 2.62 1.58 4.62 2.86 1.94 1.7 2 1/2xl 1.50 2 1/2x2 314 3.12 1.83 5.56 3.38 2.46 16 21/2x11/4 2.00 2 1/2x2 314 3.12 1.83 5.56 3.38 2.44 3.6 2,1/2x1 .112 ' 2.00 2 1/2x2 314 3.12 1.83 5.56 3.38 2.44 3.6 3x1 1.50 2 1/2x2 3/4 3.44 2.15 6.25 3.91 2.78/ 3.8 3xl 114 2.00 2 1/2x2 314 3.44 2.15 6.25 3-91 2.71> 3.8 3X1 1,12 2.00 2 1/2x2 3/4 3.44 2.15 6.25 3.91 2.76 3.8 3x2 2.50 2 1 2x2 3/4 3.44 2.15 6.25 3.91 2.74 4.4 41 1,50 2 1/2x2 314 4.00 2.65 7.25 3.83 3.34 4.6 4x.1114 2.00 2 1/2x2 3/4 4.00 1 2.65 7.25 3.83 3.32 4,6 4x1 1/2 2.00 2 1/2x2 3/4 . 4.00 2.65 7.25 3.83 3.32 4.6 4x2 2.50 2 1/2x2 3/4 4.00 2.65 7.25 4.52 3.30 4.8 4x2 1/2 2.75 2 1/2x2 314 4.00 2.65 7.25 4.52 3.07 5.4 6x1112 2.00 2 518x4 5.12 3.71 9.38 3.86 4.44 7.5 W 2.50 2 5/8x4 5.12 3.71 9.38 4.42 8.0 6x2112 2.75 1 2 5/8x4 5.12 3.T1 1 9.38 _4.42 4.42 4.19 8.0 GROOVED. NOMINAL SIZE (IN.) HOLE DIA. +.125/-0.0 NUT&BOLTS DIMENSIONS QTY. SIZE A B C D APPROX. WEIGHT EACH - 3x1 1,12 2.00--] 2 1/2x2 3/4 3.44 2.15 6.25 3.91 3.8 3x2 2.50 i 2 1/2x2 314 3.44 2.15 6.25 3.91 4.4 4x1 112 _ 2.00 2 1/2x2 3/4 4.00 2.64 7.25 3.83 4.6 4x2 2.50 2 1+2x2 3/4 4.00 2.65 ) 7.25 4.52 4.8 4x2 112 2.75 2 1i2x2 314 4.00 2.65 7.25 4.52 5.4 4x3 1 3.50 2 1/20114 4.13 2.65 7.25 5.12 7.6 6x2 ` 2.50 2 5/8x4 5.12 3.71 9.38 4.42 8,0 6x21/2 2.75 2 5/8x4 5.12 3.71 9.38 4,42 8,0 6x3 3.50 2 5/8x4 5.25 3.71 9.38 5.62 9.7 6x4 4.50 2 5/8x4 5.38 3.71 9.38 6.50 13.6 NOTE: Please consult the Mechanical Branch Tee installation information in this catalog. Please consult the Mechanical Branch Tee flow data in this catalog. All sizes of MT-1 and MT-2 Mechanical Branch Tees may be used as mechanical crosses. 8 IT ELDING BRANCH'OUTLET FITTINGS UNIFIED DESIGN,. SERIES F�mc4offy muUM0 C aFaUL ft� APPROVED LISTED MERIT MANUFACTURING CORPORATION 319 Circle of Progress • Pottstown, Pennsylvania 19464-3811 Merit Weld-MiserTM Tee -Let® Welding Branch Outlet Fittings offer the user a high strength, low cost forged thread- ed and grooved line of fittings specifically designed and manufactured to be installed on schedules 5 thru 10, propri- etary thin wall flow pipe and standard wall pipe. Unified DesignTM Series Merit's Unified DesignTM Series carries all important design considerations into its entire line of welding branch outlet fittings. Merit Weld -Miser Tee -Lets are designed and manufactured to reduce the amount of weld required to install the Tee -Lets on thin wall or proprietary flow pipe. Typically only one weld -pass completes the installation. Merit Tee -Lets install with less weld volume than any other brand of welding outlet fittings for fire sprinkler appli- cations. To accomplish this: • The contoured end of the fittings employs a reducd outside diameter. Two major advantages are immediately apparent: • The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or main thereby insuring complete penetration without cold welds, weld roll -off, burn -through or excessive distor- tion. • On the smaller sizes a heavier section is maintained on the threaded end of the fitting. This protects the threads from damage during shipping and handling prior to installation as well as from weld distortion. • Each outlet size 1-1/2" and larger, whether male or female threaded, grooved or beveled requires the same hole size in the header pipe. This simplifies the installa- tion process. General Specifications • Tee -Let welding outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical require- ments of ASTM A-53, Grades A or B, Type E. Ease of installation is assured when automatic welding equipment is used to install Merit Tee -Lets. • Threads are cut in accordance with the requirements of ANSI B1.20.1, 300 lb. class, national standard for tapered pipe -threads. BS21:1985 BSPT threads are available. • Tee -Let threaded and grooved welding outlet fittings are UL/ULC Listed, and FM Approved for use in the fire sprinkler systems installed in accordance with the requirements of NFPA Bulletin 13. They are rated for 300 PSI operation in fire sprinkler systems, and higher pressures in other non -critical piping systems. Send for pressure ratings perASME/ANSI B31. • Tee -Lets are offered in a wide variety of header sizes. The consolidated header sizes shown in the following charts allow the fit- tings to be installed on more than one header size, while permitting the first size listed to fit the header perfectly, while a small gap along the longitudinal centerline of the header will appear for the second size listed. Branch Outlet Fittings shall be Merit Weld-MiserTM Tee -Leto, lightweight forged steel, employing low weld volume profile to provide for full penetration welds with minimum burn -through and pipe distortion on schedules 5 thru 10, proprietary thin wall, and standard wall _ pipe. Threads are to be ANSI B1.20.1, tapered 300 lb. class or BS21:1985, and the bore of the fittings calculated to improve flow. Welding outlets to be UL Listed, FM Approved for use conforming to NFPA, Bulletin 13 and pressure rated for 300 PSI maximum. Tee- Letsa by Merit Manufacturing Corporation, Pottstown, Pennsylvania 19464 U.S.A. How to order —Use either of the following methods for ordering Merit® Weld-MiserTM Tee -Lets®. Method No. 1 — Specify quantity desired followed by the part number shown in the "dimensions" chart for the type and size of outlet desired. QUANTITY PART NUMBER Method No. 2 — Use the following system: — x Type Merit Steel Quantity Outlet Size Header Size Weight End Tee -Let Material Always order Column "A" Insert size Sch. 10 A— Female Thread a few more of chart consolidation Standard B — Male Thread than actually from C — Cut Groove required for Column "B" C/R — Roll Groove the job. of chart Type A - Female Threads A I „ 1 _ ._._.------ _._.t._.------- B ._._ I I -----------I-------- -- Dimensions & Corresponding Part Numbers Part :Number BSPT Nammal-Nominal Outlet SzeA 'Headef _. Sae6 ;, Outlet Length S,iie,C, Inside ;,Diameter =Sze,D Make <yp SiieM Wetght' Each += 4t,Lkgs, 1002002 1/4 x 1-1/4-8 0.080 - 6 x 6,200 0.04 1005012 1/2 x 1-1/4 - 1-1/2 1.063 0.700 0.500 0.171 - 13 x 32 - 40 27.0 17.8 12.7 0.08 1005015 1-1/2-2 1.063 0.700 0.500 0.171 - 40-50 27.0 17.8 12.7 0,08 2-2-1/2 1.063 0.700 0.500 0.171 1005020 - 50-65 27.0 17.8 12.7 0.08 1005025 2-112 -8 1.063 0.700 0.500 0.169 - 65 -200 27.0 17.8 12.7 0.08 1007012 314 x 1-1/4 -1-1/2 1.125 0.900 0.500 0.260 - 19 x 32 - 40 28.6 22.9 12.7 0.12 1007015 1-1/2-2 1.125 0.900 0.500 0.260 - 40-50 28.6 22.9 12.7 0.12 2-2-1/2 1.125 0.900 0.500 0.260 1007020 - 50-65 28.6 22.9 12-7 0.12 1007025 2-1/2-8 1.125 0.900 0.500 0.256 - 65-200 28.6 22.9 12.7 0.12 1010012 1 x 1-1/4 - 1-112 1.250 1.145 0.500 0.331 1110012 25 x 32 - 40 31-8 29.1 12.7 0.15 1010015 1-1/2-2 1.250 1.145 0.500 0.331 1110015 40- 50 31.8 29.1 12.7 0.15 2-2-1/2 1.250 1.145 0.500 0.320 1010020 1110020 50-65 31.8 29.1 12.7 0.15 1010025 2-1/2-3 1.250 1.145 0.500 0.314 1110025 65- 80 31.8 29.1 1 12.7 0,14 1010030 3-4 1.250 1.145 0.500 0.309 1110030 80-100 31.8 29.1 12.7 0.14 1010050 5-8 1.250 1.145 0.500 0.291 1110050 125-200 31.8 29.1 12.7 0.13 1012012 1- 1/4 x 1-1/4 - 1-1/2 1.375 1.490 0.500 0.432 1712012 32 x 32 - 40 34.9 37.8 12.7 1 .019 1012015 1-1/2-2 1.375 1.490 0.500 0.421 1112015 40-50 34.9 37,8 12.7 .019 2 - 2-1/2 1.375 1.490 0.500 0.421 1012020 1112020 _50- 65 34.9 37.8 12.7 .019 1012025 2-1/2-3 1.375 1.490 0.500 0.411 1112025 65-80 34.9 37.8 12.7 .019 3-4 1.375 1.490 0.500 0.389 1012030 1112030 80- 100 34.9 37.8 12.7 .018 1012050 5-8 1.3 55 1.490 0.500 0.389 1112050 125-200 34.9 37.8 12.7 .018 I I r G-P% J rI U MM mm Part `Number- BSPT . = Weight = Each;;,`. Lb. / kgs':: Nommaf Outlet; S,ie A Nemmal Header Size BL Outlet Length :? Sae C .: Instde Dtametee Sae D ," � Make; up ;'. Sue M 10 01015 1-1/2 x 1-1/2 1.625 1.610 0.875 0.477 1115015 40 x 40 41.3 40.9 22.2 .022 2 1.625 1.610 0.875 0.477 1015020 1115020 50 41.3 40.9 22.2 .022 1015025 2-1/2 1.625 1.610 0.875 0.477 1115025 65 41.3 40.9 22.2 .022 3-4 1.625 1.610 0.875 0.477 1015030 1115030 80-100 41.3 40.9 22.2 .022 1015040 4 1.625 1.610 0.875 0.477 1115040 100 41.3 40.9 22.2 .022 1015050 5-8 1.625 1.610 0.875 0.477 1115050 125-200 41.3 40.9 22.2 .022 1020020 2 x 2 1.750 2.067 0.875 0.857 1120020 50 x 50 44.5 52,5 22.20.38 2-1/2 1.750 2.067 0.875 0.829 1020025 1120025. 65 44.5 52.5 22.2 0.38 1020030 3 1.750 2.067 0.875 0.829 1120030 80 44.5 52.5 22.2 0.39 1020040 4 1.750 2.067 0.875 0.800 1120040 100 44.5 52.5 22.2 0.36 1020050 5 1.750 2.067 0.875 0.743 1120050 125 44.5 52.5 22.2 0.34 6 1.750 2.067 0.875 0.743 1020060 1120060 150 44.5 52.5 22.2 0.34 1020080 8 1.750 2.067 0.875 0.743 1120080 200 44.5 52.5 22.2 0.34 1025025 2-1/2 x 2-1/2 2.215 2.469 1,125 1.250 1125025 65 x 65 54.0 62.7 28.6 0.55 3 2.215 2.469 1.125 1.200 1025030 1125030 80 54.0 62.7 28,6 0.55 1025040 4 2.215 2.469 1.125 1.150 1125040 100 54.0 62.7 28.6 0.52 1025050 5 2.215 2.469 1.125 1.150 1125050 125 54.0 62.7 28.6 0.52 1025060 6 2.215 2.469 1.125 1.150 1125060 150 54.0 62.7 28.6 0.52 1025080 8 2.215 2.469 1.125 1.150 1125080 200 54.0 62.7 28.6 0.52 1025030 3 x 3 2.500 3.068 1.500 3.100 - 80 x 80 63.5 77.9 38.1 1.41 1025040 4 2.500 3.068 1.500 3.100 - 100 63.5 77.9 38.1 1,41 1025050 5 2.500 3.068 1.500 3.100 - 125 63.5 77.9 38.1 1.412 1025060 6 2.500 3.068 1.500 3.100 - 150 63.5 77.9 38.1 1.412 1025080 8 2.500 3.068 1.500 3.100 - 200 63.5 77.9 38.1 1.41 1040040 4 x 4 3.000 4.026 2.000 5.000 - 4 x 100 76.2 102.3 50.8 2.27 5 3.000 4.026 2.000 5.000 1040050 - 125 76.2 102.3 50.8 2.27 1040060 6 3.000 4.026 2.000 5.000 - 150 76.2 1 102.3 50.8 2.27 8 3.000 1 4.026 2.000 5.000 1040080 - 200 76.2 102.3 50.8 2.27 Note: Tee -lets are manufactured to fit size -on -size, that is the contoured shape on a given Tee -Let is made to fit perfectly on the first listed header size. If installed on the sec- ond header size marked on the fitting, a slight gap of approximately 1/32" will appear along the longitudinal centerline of the header. For example, a 1" x 2 - 2-1/2" Tee -Let, is a 1" outlet fitting manufactured to fit perfectly on the 2" header size listed, while leaving a 1/32" gap along the longitudinal centerline of the 2-1/2" size. If a perfect fit is required for a 2-1/2" header pipe, then a 1" x 2-1/2 - 3" Tee -let would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. ='V1'1-A Cut Groove Std. Wt. Male Thread Std. Wt. Roll Groove Sch. 10 Dimensions & Male ` Cut Rotl Nominal Nominal Outlet Ingioe 9*0e ' Wall Weight;: :L £'Gro- oo"; �Qtr �gth, �Diarneter Diameter. . ...... Std Wt. Std;Si ^ D . ii -WE p:/ k i Re - SiIze'C , -ze Sae id . .. .1. 1" .. I I Corresponding 1310012 2010012 2210012 1 x 1-1/4 - 1-1/2 3 1.049 1.315 0.133 1.500 Part Numbers 25 x 32-40 80 26.6 33.4 3.4 30 all U111 V1 .3 1310015 2010015 2210015 1-1/2-2 3 1.049 1.315 0.133 1.500 ��"'. ' I I ' , - ":� -, , rijritry) Cut �- :::.,Rol d " 1. 1�1 Wall Thickness 40-50 80 26.6 33.4 3.4 30 Thir6iad Groove_ -Groove' Nominal Nominal '0u11e(' . lrtside Diarrieler Outside ;Wei fit 1210020 2010020 2210020 2-2-1/2 3 1.049 1.315 0.133 1.500 Outlii. 1. JSch. 16 Diameter ScIfAD Hpiticir Ur.0h s1d, j� 50-65 80 26,6 33.4 3.4 31) F S I . .. Size D -Sae �Siiiiili M 09's tie �S!j6'9 "' Size C: S" 13f0025 2010025 2210025 2-1/2-4 3 1.049 1.315 0133 1.500 1325-025 202502-5 2225025 2-1/2 x 2-1/2 3 2.469 2.6352.875 1 0.203 0.1201 1.500 65 - 100 80 26.6 33.4 3.4 30 2125025 65 x 65 80 62.7 67.0, 76.2 5.0 3.0 30 1310050 2010050 2210050 5-8 3 1.049 1.315 0.133 1.500 1325030 2025030 2225030 3 3 2.469 2.635 2.875 0.203 0.120 1.500 1 125-200 no 26.6 - 33.4 3.4 30 2125030 so 80 62.7 67,0 , 76.2 5 1 30 1312012 2012012 2212012 1-1/4 x 1-1/4 3 1.368 1.660 0.140 1.500 1325035 2025040 2225035 4 3 2.469 2.635 2.875 0.203 0.120 1.500 32 x 32 80 34.7 4L2 1 3.6 30 1 2125040 loo 100 BO 62.7 67.0 76.2 5.0 3.0 30 1312015 2012D15 2212015 1-1/2 3 1.368 1.660 0.140 1.500 1325050 2025050 2225050 5 3 2.469 2.635 2.875 0.203 0.120 1.500 40 go 34.7 42.2 . 3.6 30 2125050 125 80 62.7 67.0 76.2 5.0 ID 30 1212020 .2012020 2212020 2-2-1/2 3 1.368 1.660 0.140 1.500 1325060 2025060 2225060 6 3 2.469 2.635 2.875 O:203 0.120 1.500 50-65 00 34.7 42.2 3.6 30 2125060 175 80 62.7. 67.0 76.2 5.0 3.0 30 1312025 2012025 2212025 3-4 3 1.368 1.660 0.140 1.500 1325080 2025080 2225080 8 3 2,469 2.635 2.875 0.203 0.120 1.500 80-100 80 34.7 42.2 3.6 30 2125080, 200 80 62.7 67.0 76,2 5.0 1 3.0 30 1312050 2012050 2212050 5-8 3 1.368 1.660 0.140 1.500 1330025 2030025 2230025 3 x 3 3 3.068 3.260 3.500 0.216 0.120 1.500 - - 125-200 so 343 42.2 3.6 30 80 X 80 80 78.0 83.0 88,0 5.0 3.0 30 1315015 2015015 2215015 1-1/2 x 1-1/2 3 1.610 1.900 0.145 1.500 1330030 2030030 2230030 3-1/2 3 3.068 3.260 3.500 0.216 0.120 1.500 40 x 40 so 40.9 48.3 3.7 30 85 80 78.0 83.0 88.0 1 5.0 3.0 30 1215020 2015020 2215020 2 3 1.610 1.900 0.145 1.500 1330035 2030035 2230035 4 3 3.068 3.260 3.500 0.216 0.120 1.500 so 80 40.9 40.3 3.7 30 100 80 78.0 83.0 88.0 5.0 3.0 30 1315025 2015025 2215025 2-1/2 3 1.610 1.900 0.145 1.500 1330050 2030050 2230050 5 3 3.068 3.260 3.500 0.216 0.120 1.500 65 80 40.9 48.3 3.7 30 125 80 78.0 83.0 88.0 5.0 3.0 30 1315030 2015030 2215030 3-4 3 1.610 1.900 0.145 1.500 1330060 2030060 2230060 6 3 3.068 3.260 80 40A 48.3 Moo 0.216 0.120 1.500 80-100 3.7 30 78.0 83.0 88.0 5.0 3,0 30 1315050 2015050 2215050 5-8 3 1.610 1.900 0.145 1.500 1330080 2030080 2230080 8 3 3.068 3.260 3.500 0.216 0,120 1.500 125 -203 80 40.9 48.3 3.7 30 20D 80 78.0 83.0 88.0 5.0 3.0 30 1320020 2020020 - 2 x 2 3 2.067 2.375 0.154 1.500 1341010 2140140 2240040 4 x 4 4 4.026 4.260 4.500 0.237 0.120 1.500 50 X so 80 52.5 60,3 3,9 30 100 X 100 100 102.0 108.0 114.0 6.0 1 3.0 30 1320025 2020025 - 2-1/2 3 2.067 2.375 0.154 1.5DO 1340050 2040050 2240050 5 4 4.026 4.260 4.500 0.2371 0.120 1.500 65 80 52.5 60.3 3.9 30 125 100 102.0 108.0 114.0 6.0 3.0 30 1320030 2020030 - 3 3 2.067 2.375 0.154 1.500 1340060 2040060 2240060 6 4 4.026 4.260 4.500 0.237 0.120 1.500 80 80 52.5 60.3 3.9 30 150 100 102.0 108.0 114.0 6.0 3.0 30 1320035 2020040 - 4 3 2.067 2.375 0.154 1.500 1340080 2040080 2240080 a 4 4.026 4.260 4.500 0.237 0.120 1.50 100 80 52.5 60.3 3.9 30 200 100 102.0 108.0 114.0 6.0 3.0 30 1320050 2020050 - 5 3 2.067 2.375 0.154 1.500 - 2060060 2260060 6 X 6 4 6,065 6.3-17 6.625 -0.280 0.134 1.500 125 80 52.5 60,3 3.9 30 150 150 1 Go 155.0 161.5 168.3 7.1 3.0 30 1320060 2020060 - 6 3 2.067 2.375 0.154 1.500 - 2060080 2260080 8 4 6.065 6.357 6.625 0.280 0.134 1.50 150 60 52.5 60.3 3.9 30 20 0 100 155.0 161.5 1 168.3 7.1 3.0 30 1320080 20200801 - 8 3 2.067 2.375 0.154 1.500 - 2080080 2280080 8x 8 4 7.981 8'329 8.625 0.322 0.148 1.50 200 80 52.5 , 60.3 3.9 30 . 200 9 1 200 1 100 203.0 212.0 213.0 8.0 3.0 1 30 DISTRIBUTED BY MADE IN U.S.A. MERIT MANUFACTURING CORPORATION 319 Circle of Progress Pottstown, Pennsylvania 19464-3811 (610) 327-4000 - Fax (610) 970-9282 Fax Toll Free 800-543-7013 www.meritmfg.com 6nuuto Dy merit manuiactunng corporation CG114-00 /1 C.I. THREADED FITTINGS FITTINGS • , A 9Minn nfSlar Pip,. Prndwf, uLC � t FM LISTED LISTED APPROVED • For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI B16.4 CLASS 125 EXCEPT PLUGS CONFORM TO ASME - - A ­1­ A 616.14. THREADS ARE NPT PER ANSI/ASME 61.20.1. <r - �•W S iY I CAST IRON 90 DEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE # MAX. WORIGNG P.S.I. DIMENSIONS WEIGHT A B EACH PIECE _ 1 CB90033 300 1.50 1.50. 0.95 11/4 CB90044 300 1.75 1.75 1.34 11/2 CB90055 300 1 1.94 1.94 1.80 2 CB90066 300 1 2.25 2.25-1 2.90 21/2 CB90077 300 1 2.70 2.70 1 4.75 u CAST • I1 COUPLING NOMINAL SIZE (INCH) ITEM CODE # MAX. WORMING P.S.I. DIMENSION A WEIGHT EACH PIECE 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 CAST IRON RED. 90 DEG. ELBOW NOMINAL SIZE (INCH) ITEM CODE # MAX. WORMING P.S.I. DIMENSIONS WEGHT EACH PIECE A B 1X11/2 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 11/4X1/2 CB90041 300 1.34 1.53 0.96 11/4X3/4 CB90042 300 1.45 1.62 1.13 11/4X1 CB90043 300 1.58 1.67 1.16 11/2x1112 CB90051 300 1.41 1.66 1.17 11/2x3/4 CB90052 300 1.52 1.75 1.28 11/2X1 CB90053 300 1.65 1.80 1.51 11/2X11/4 CB90054 300 1 1.82 1.88 1.62 2X1/2 CB90061 300 1.49 1.88 2.00 2X3/4 I CB90062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X11/4 CB90064 300 1.90 2.10 2.30 2X11/2 CB90065 300 2.02 2.16 2.60 F CAST • STRAIGHT NOMINAL SIZE (INCH) ITEM CODE # MAX. WORMING P.S.I. DIMENSIONS WEIGHT EACH PIECE A B 1 CT333 300 1.50 1.50 T.21 11/4 CT444 300 1.75 1.75 1.87 11/2 CT555 300 1.94 1 1.94 1 2.51 2 CT666 300 1 2.25 1 2.25 3.96 2112 CT777 300 1 2.70 1 2.70 6.45 CAST IRON 45 DEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE # MAX. WORIONG P.S.I. DIMENSIONS WEIGHT EACH PIECE A B 1 CB45033 300 1.12 1.12 0.84 11/4 CB45044 300 1.29 1.29 1.40 11/2 CB450551 300 1.43 1.43 1.80 2 CB450661 300 1 1.68 1 1.68 2.79 F� A i CAST IRON NOMINAL SIZE (INCH) ITEM CODE # MAX. WORIONG P.S.I. DIMENSION WEIGHT EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPL002 300 1.07 0.17 1 CPL003 300 1.25 0.28 11/4 CPL004 300 1.36 0.44 11/2 CPL005 300 1.45 0.62 2 CPL006 300 1.56 0.91 Page 38 Q FITTINGS � /" .l Di*i iun ofSmr Pipe PrnAuus .... A .: C.I. THREADED FITTINGS c lJ L FM LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON'CROSS NOMINAL SIZE (INCH) ITEM CODE # MAX. WORIUNG P.S.I. DIMENSIONS WEIGHT EACH PIECE A B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 11/4X1 CX043 300 1.58 1.67 2.05 11/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 CAST IRON REDUCING TEE NOMINAL SIZE (INCH) ITEM CODE # MAX. WORMING P.S.I. DIMENSIONS WEIGHT EACH PIECE A I B C 0 .26 1.26 1.36 1 X3 4 CT332 .300 1.37 1.37 1.45 1.10 3 1 323 300 1.50. 1.45 1.50. 1.18 2 X112 T335 300 1.80 1.80 .65 .73 11 1 4 CT432 300 1.45 1.37 1.62 1.38 7 1.47 1/4XIXI 114 CT434 300 1.75 1.67 1.75 1.80 114X114X1/2 CT441 300 1.34 1.34 1.53 1.37 4 14X1 CT443 300 1.58 1.58 1.67 .65 114 114X2 CT446 300 2.10 2.10 1.90 2.55 2X1 X 4 T532 300 1.52 1.37 .75 . .65 1 1 2 1 X1 1 4 CT534 300 1.82 1.67 1.88 2.00 2 114 2 541 300 1.41 1.34 1.66 1.58 2X11 1 T543 -300 1.65 1.58 1.80 1.85 112x114x114 CT544 300 1.82 1.75 1.88 2.22 11/2x114x11/2 CT545 300 1.94 1.88 1.94 2.45 11/2X11/4X2 CT546 300 2.16 1 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 11/2X11/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 11/2X11/2X2. CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X11/4X2 CT646 300 2.25 1 2.10 2.25 2.80 2X11/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X11/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X11/2X1 CT653 300 1.73 1.65 2.02 2.54 2X11/2X11/4 CT654 300 1.90 1.82 2.10 2.85 2X11/2X11/2 CT655 300 1.49 1.41 1.88 2.24 2X11/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X11/4 CT664 300 1.90 1.90 2.10 3.32 2X2X11/2 CT665 300 2.02 2.02 2.16 3.72 2x2x21/2 1 CT667 300 2.60 2.60 2.39 5.10 Page 39 Fig. 2 — Adjustable Band Hanger c(& Fig. 2NFPA — Adjustable Band Hanger with Reduced Rod 'Size Range — Size 21/2" thru 4" pipe. Material — Carbon Steel, Pre -Galvanized -Function — Recommended for the suspension of non -insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Federal Specification VVW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish — Pre -Galvanized Note — Available in Stainless Steel materials. Order By — Figure number, pipe size and material Dimensions • Weights Pipe Max. Rec. Approx Wt./100 Size Rod Size A B C Load Lbs. Fig. 2 Fig. 2NFPA 21/2 1/2* 5114 41/< 11/8 600 41 40 3 1/2* 6 41/a 1'/e 600 45 43 3'/2 1/2* 73/8 51/4 r 21/8 600 52 50 4 5/8* 73/e 5 15/a 1000 59 56 5 5/8** 9 61/a 21/4 1250 97 95 6 3/4** 93/e 61h 17/8 1250 139 105 * 3/8" nut is used when NFPA rod sizing is requested. ** 1/2" nut is used when NFPA rod sizing is requested. ® Office/Manufacturing Facility • 1375 Sampson Ave • Corona. CA 92879 * Ph: 951.737.5599 • fax: 951.73Z0330 Customer Service - 800.786.5266 www.tolco.com Fig. 68 -Wide Throat Top Beam "C" Clamp w/Locknut Size Range — 3/8" thru 3/4" rod Function For attachment to structural shapes requiring Awider throat especially under roof with bar joist construction. This clamp may be used in the set screw down position only. Approvals — Factory Mutual Engineering approved for rod sizes 3/8" and 1/2". Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19. Finish — Plain Note — Available in Electro-Galvanized finish. Order By — Figure number, rod size and finish Note — Do not over tighten set screw. m Office/Manufacturing Facility • 1375 Sampson Ave. • Corona. CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 www.tolco.com Fig. 98 - Rod Stiffener Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number t s ~ Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1`` increments Material — Carbon Steel Maximum Temperature — 750'F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Fig. 100 -All Thread Rod Full Lengths Size Range — Secures 3/8" thru 7/8" rod in 10' lengths Material — Carbon Steel Maximum Temperature — 750'F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish - Dimensions -Weights Max Rec. Load Lbs. _ Rod For Service Temps Approx. Size 650'F 750'F Wt./100 1 /4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1'/4 8000 7140 360 1V2 11630 10370 510 Dimensions -Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650'F 750'F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 ® Office/Manufacturing Facility • 1375 Sampson Ave. - Corona. CA 92879 - Ph! 951.737 5599 - Fax: 951,737.0330 Customer Service • 800.786.5266 -- www.toko.com STEEL —Sidewinders Self -Drilling • Self -tapping steel screw shown with retainer nut SWDR .screws include retainer nut #14SW (Item #101-red) Sidewinders & Sammys 1/2" rod 'It (Horizontal Mount) Use #14SW Nut Driver (Item #101) Item # Model Screw Description Minimum Thickness Maximum Thickness Actual Shear/Pullout Box Qty Weight (per 100) Case Qty 2003 SWD 100 1/4-14x1 .066"-16 ga 1/4" 1477# /16 ga 100 6.00 1000 407 SWD 200 1/4-14x2 .066"-16 ga 1/4" 1477# 116 ga 100 6.50 1000 ' 1 (Horizontal t -Use #145W Nut Driver (Item #101) Approval Item# Model Screw ULTest UL/FM Minimum Maximum Actual Box Weigh Description Loadlb. Pi Size Thickness Thickness Shear/Pullout Qty (per 10( NFPA 39 ISWDIO 1/4-14x1 .066"-16 ga 1/4" 1477# 116 ga 100 6.00 NFPA 40 JSWD 15 1/4-14xl 1/2 No° e 'ituHrdeameler�destgnip�dfo manyx„(arS �ti� &(1"lenAk 1.00 7.50 NFPA 41 SWD20 1/4-14x2 tirro gh;Sii'!??U(?' Sength}fareronsrdnt'On1�5tlie��e/rihs airy 100 6.50 NFPA 42 SWD 516 5/16-18x1 1/4 100 7.00 UL•NFPA 46 SWDR 11/2" 1/4-20x11/2 1500# 4 .25"-1/4" I/2" 2375#/.25"-1/4" 100 7.25 UL-,NFPA 43 SWDR 1" 1/4-20x1 1500# 4- .036"-20 ga 1/4" 1900# /20 ga 100 7.00 UL•NTPA 44 SWDR 516 5/16-18xl 1/4 1500# 4 .036"-20 ga 1/4" 2486# / 20 ga 100 8.25 NFPA 45 SWT 15 12-24xl 1/2 .25"-I/4" 1/2" in 6.25 "PERFOIRMANCEDATA FOR STEEL SHEET STEEL GAUGES "PERFOIRMANCEDATA FOR STEEL SHEET STEEL GAUGES Gauge No. 1 114 1 3/16 1 12 1 14 1 16 1 18 1 20 1 22 1 24 26 Decimal Equivalent 1 .25 1 .188 1 .105" 1 .075" 1 .060" 1 .048" 1 .036" 1 .030" 1 .024" 1 .018" Ultimate Pullout Values - Sammys (average lbs. ultimate) Fastener Steel Gauge Model Dia. Pt. 20 18 16 14 12 3116 114 DST 1/4 #3 446# 613# 970# 1145# 1544# 3190# DST 516 5/16 #3 457# 568# 1209# 1712# 2422# 3716# TEK 50 #12 #5 487# 699# 913# 1527# 3270# 3593# DSTR 1 112" #12 #5 3270# 3593# DSTR 1" 1/4 #3 1510# -DSTR 516 5/16 #3 2200# Ultimate Shear / Pullout Values - Sidewinders (average lbs. ultimate) Fastener ISteel Gauge Model Dia. Pt. 20 1 18 16 14 12 3/16 1/4 SWD 1/4 #3 1477# SWDR 1 1/2" #12 #5 2375# SWDR 1" 1/4 #3 1900# 1900# SWDR 516 5116 #3 2480# 2480# Aluminum Curtain Wall Extrusion ....... .__......_...._._.__.... _....___.___........__.._._....___._._.......... _._._...._....._...-..._._.. _.._,......_ Ultimate Pullout Values (average lbs. ultimate) Fastener Thickness Model Dia. Pt. .114 .092 .365 .132 DST 10 1/4 #3 1265# 2750# SWD 10 1/4 1 #3 1120# 1420# For fastening/anchoring in high vibratory environments, consult local code authorities for accepted anchoring devices Note. Screws mutt be installed with appropriate nut driver to comply with warrant,, Page 7 s OTTER SELLS P ® PBA-AC & PBD-DC UL Listed, FM Approved - Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) _ Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized . 24VDC (20.4 to 31.2) Polarized i 6" BELL SHOWN Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: SIZE INCHES (mm) VOLTAGE MODEL NO. STOCK NO. NT CURRENT (MAX TYPICAL dI3 AT 10 FT. (3m) (2) MINIMUM dI3 AT 10 FT. (3m) (1) 6(150) 12VDC PBD126 1706012 .12A 85 76 8 (200) 12VDC PBD128 1708012 .12A 90 76 10 (250) 12VDC PBD1210 1710012 .12A 92 76 6 (150) 24VDC PBD246 1706024 .06A 87 76 8 (200) 24VDC PB0248 1708024 .06A 91 79 10 (250) 24VDC PBD2410 1710024 .06A 94 79 6(150) 24VAC PBA246 1806024 .17A 91 76 8(200) 24VAC PBA248 1808024 .17A 94 76 10 (250) 24VAC PBA2410 1810024 .17A 94 76 6 (150) 120VAC PBA1206 1806120 .05A 92 82 8(200) 120VAC PBA1208 1808120 .05A 99 82 10 (250) 120VAG PBA12010 1810120 .05A 99 85 J Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories _ as specified in UL Standard 464. UL temperature range is -30' to 150°F (-34° to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. Potter Electric Signal Company • 2081 Craig Road, St_ Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 905-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8850001 - REV P PAGE 1 OF 2 MFG. #5400776 - 3/99 I , PO BELLS TTER ® PBA-AC & PBD-DC FIG.1 BELLS I (2so) I 8 I I I (200) 6^ (150) I I I I L C7_J I --�2 11/1611 (68) DWG. #776-1 DIMENSIONS INCHES (mm) FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONE THREADED 1/2" CONDUIT ENTRANCE I 5 3/4" 0-- (746) -►J t S/8 �. (41) DWG. #776-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) RFD (IN) CBLACK �PROM CONTROL �ANE.L BELL FF OR -LINE PRECEDING BELL R NLACK (IN) CAU NON: S WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. th f I NO TES: t. OBSERVE POLARITY TO RING D.C. BELLS. t 2. RED WIRES POSITIVE (+) 3. BLACK WIRES NEGATIVE (-) DWG. #776-3 (66) 4 t/a" INSTALLATION 1. The bell should be mounted a minimum of 8 ft. (2.4m) from the floor or as close to the ceiling as possible. - _ 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REV P PAGE 2 OF 2 MFG. #5400776 - 3/99 VSR-F .(E)POTTER VANE TYPE WATERFLOW ® ALARM SWITCH WITH RETARD U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterflow .switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8". LPC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterflow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 gallons per minute or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked Seruce Pressulttp:to450 PSI Minimum Flow Rate for Alarm: 10 GPM Maximum Surge: 18 FPS Contact Ratings: Two sets of SPDT (Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. • NEMA 4/IP54 Rated Enclosure - use with appropriate conduit fitting. • Temperature Range: 40°F/120°F, 4.5°C/49°C • Non -corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizes Available: Steel Pipe schedules 10 thru 40, sizes 2" thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 , These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" of a fitting which changes the direction of the waterflow or within 24" of a valve or drain - Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 114" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow_ Install the saddle strap and tighten nuts alternately to an eventual 50 ft- Ibs. of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • wvvw.pottersignal.com I PRINTED IN USA MKT.#8800001-REVS PAGE 1 OF 2 MFG. #5400761 -7/00 __J (2),POTTER FIG. 1 SWITCH TERMINAL _ CONNECTIONS CLAMPING PLATE - TERMINAL p0G l �G DNC' #923-3 CAUTION: An-uninsulated section of a single conductor should not be looped around the termi- nal,and serve as two sepa- rate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG. 2 VSR-F VANE TYPE WATERFLOW SWITCH WITH RETARD DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME RETARD ADJUSTMENT: TO CHANGE TIME TURN KNOB (EITHl FOR DESIRED TIME DELAY. USE THE AMOUNT OF RETARD NECESSARY TO FALSE ALARMS, A "B" SETTING IS U ADEQUATE FOR THIS. FACTORY IS TO INSTALL, DRILL HOLEAS INDI PIPESIZE HOLESIZE 2"to21/2" 1114"+1/8"- (5Ommto65mm) (33mmt2mrr 3" to 8" 2" t 1 /8" (8ommto20omm) (50mmt2mrT DWG. #761-30 FIG. 3 TYPICAL ELECTRICAL CONNECTIONS 2 SEIS OF NORMALLY OPEN CONTACTS WATERFLOW ZONE EOLR FROM CLOSE ON ALARM ON FIRE PANEL FIRE PANEL F LQA f - COW XO NC NO OOW IIC NC C9NM ND MC Lei POSITIVE DC THE NC AND NO MARKINGS OR Hur Ac ON THE SWITCH ARE FOR AN ALAF44 CONDITION. NEGATIVE DC THE CONTAWS ARE REVERSED OR NEUTRAL AC WHEN THE DEVICE IS IN Dom, pst_s THE NORMAL CONDITION. DII W NOTES: 1. The Model VSR-F has two switches, one can be used to operate a central station, pro- prietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. A condition of LPC Approval of this product is that the electri- cal entry must be sealed to exclude moisture. R- 3. For supervised circuits see "Switch Terminal Connec- tions" drawing and caution note (Fig. 1). TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL. 5OFr.-LBS OF TORQUE MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE iN OPPOSITE DIRECTION OF WATERFLOW ID SETTINGS (IN SECS.) B C D E -40 35-55 I,,)-,o 60-90 FIG. 4' To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in -accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line,, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be - tested in accordance with the testing instructions. i I` PRINTED IN USA MKT. #8800001- REVS PAGE 2 OF 2 MFG. #5400761 -7/00 Fire Protection Sprinkler Service Gauge ASHCROFT`I Ashcroft Fire Protection Sprinkler pressure gauges are Underwriters Laboratory Listed and Factory Mutual approved for fire protection sprinkler service. The 0130CI psi pressure range of this -gauge is used on "wet" systems where water is available to the sprinkler heads. The 0/8CI retard to 250 psi pressure ranges are used on dry systems where the lines are filled with air pressure until system activation. Among the features of these pressure gauges are: — The patented Spring Sus- pended Movement with polyester segment designed to provide unequalled shock and vibration resistance resulting in superior performance. — Ultrasonically cleaned and silicone lubricated gearing to assure smooth operation and extended gauge life. — Corrosion resistant ABS (Acrylonitrile Butadiene Styrene) - case meets Underwriters Laboratory UL-393, and Factory Mutual requirements. Product Specifications Ashcroft! Model Number: 1005PJ XUL — Size: 3 1121 Diameter Case: ABS (Acrylonitrile I Butadiene Styrene) _I Window: Polycarbonate - Dial: Black figures on white background Pointer: Black, Aluminum Movement: Patented Spring Suspended with Polyester Segment Bourdon Tube: Bronze Socket: Brass, Soft Soldered Connection: 1/41 NPT Lower _ Accuracy: ABMEI 840.11 Grade B Mounting: Stem Ranges: 0/30CI psi (water) 9(8QI retard to 250 psi (air) U.L., U.L. of Canada Listed and FM approved. Equivalent (single or dual scale) metric ranges are available. I Dimensions DIMiENSIONSI I N INCHES (MM) —� U B� -E SIZE/TYPE A B C D E 3 W2,1 3 a'/U 'I M44 2 >2'3.< A YT4; EHA Order lnforma Lion 35 IN 1005 F 02L Dial Size: 31/21' Patented Spring Suspended Movement Case Type Number: 1005 Case Material: ABS Connection Size and Location: 1/41 NPT Lower XUL for UL 393 listed and FM approved Range: 0/30a PSI 3004 Im 10-1 FlangeFit@ Nut, Bolt& Gasket Kit Description / FlangeFit Nut, Bolt and Gasket include everything needed to make-up a flanged assembly. Suit- able for use in all flanged connections in fire sprin- kler systems including flanged alarm valves and back -flow preventers and other Class 125 flanges. Each kit includes one 1/8" red rubber ring gasket and the correct number of plated hex head bolts and nuts per flange. Each kit is skin -packed to a durable cardboard backing to make sure that all kit com- ponents get to the job site. Eliminates the need to carry a separate inventory of loose nuts, bolts and gaskets reducing inven- tory items and the labor costs associated with providing this solution. Installation Install according to spe- cific manufacturers in- structions for flanged equipment. Specs Each kit contains one 1/8" thick red rubber ring gas- ket and the following A307 plated nuts and bolts according to size: 21', 2 1 /2", 3" 4 bolts & nuts 4", 511, 611, O„ 8 bolts & nuts 10", 1211,1411 12 bolts & nuts Forquestions: 1 800 344-1822 1 800 344-3775 fax http://www.fppi.com info@fppi.com ©2000 Fire Protection Products, Inc. FIVALCO BUTTERFLY VALVE INSTALLATION AND MAINTENANCE GUIDE Table of Contents . General Description 1 Care and Maintenance 1,2 Firefly BT 3 Firefly BG 4 Fireriser DG 5 Fireriser DW 6 Fireriser HPG 7 Fireriser HPW g Friction Loss 9 I Physical Data 10 Page i Ftv U V NC. The Fivalco grooved butterfly valve should be connected to. the piping system with approved couplings or flange adapters. Flow may be from either. direction, and the valve ,may be positioned in any direction. Fivalca'butterfly valves have been designed with a slow close hand wheel operator, which effectively minimizes water hammer, These valves feature minimum flow restriction and pressure loss when in the fully open position. When the valves are, received from 'the manufacture they should be bandied carefully to avoid breakage and damage to the seating area- Betor.4 installation of the valve, clean piping, flange and coupling. When the valves, .closes hard, it is usually clue to devris lodged 'in the sealing area. Often. this: may be corrected by backing off lhf hand wheel and c'losirig` again. The valve Mould never be forced to. seat, by applying a wrench to the hand wheel as this may _distort the valve compon,e»tsi or score the. seating surface. The use of < excessive, force -to. open or close: the valve +iolates all warranties whether express or implied': The. Thlet and outlet pipe adiace`nt to the valve should be properly supported to prevent excessiv4; stress- can the Valve. body. The valve should not be used to force a pipeline into 30SI, ignilasAws ma result in distortion of the valve/body. otfons to the optional tamper,-swit;eh-.must :be.in �ical Code (NFPA 72) and requ[rettlents of;the local Fivalco butterfly valves require no regular'`mantenance, however tt is advisable to inspect;..arid`verify`proper operation of the unit annually or iri aodordanee with the, authorit}r having jurisdiction. The inspectron should include 'a visual check for leakage at the. valve pipe connection and -body:to operator connection. Inspection and rr a' Menance should. be• performed by a qualified inspection service.. Fivalco butterfly valves are provided with internal supervisor position switches, The tamper switch operates by a cam connected to the valve stem. The switch will change position and close within two (2) full turn of the hand wheel from the fully open position. Switch # 1:Switch 42 For connection, to the supervisory crrcurt Attxiiiary switch connected per authority. Normally closed 2'Red Normally closed . t Red Normally open 2 :Yellow Normally .open : t. Blue Common 21Nhrte Common 1 slack Ground Lead 1 Green 71 F�ival co Inc; warrants each -metal valve to be free fromdefect in maternal and workmanship under normal use and service for a period of one year from the - date of, purchase. In the event that any defect is discovered which may be covered by this warranty, the owner should contact F'ivaico Inc, in writing or by telephone at this Address. The owner,may tie instructed to :return the valve at. owner`s expense to Fivalco Ind or an authorized Fivalco location for inspection In th case that inspection ;reveals that th-exalve is. defective, it wilt,be.to' laced at_Frualco1 s expense. Replacements shall ,be shipped free of charge to the ouurrdad that° the, vair�e was instaifed, in: aGeordance with Fivalc,o lnc ` Instructrarts arad to accordance with flip local authority haying furrsdictivn ' Ta the,extent-permitted. by law this warenty specifically exc}udes incidental and consequential damages •qf l every type grid desorption resulting from :any cia�med defect in material .cir. wor pansh.,11 includr;i g but not ,limited to, peisoral miur[es and properly damages To the extended permitted: permitted bx law,. irnpl%ed warranties: ol; rb dhantability and fitness for particular purposes are limited induration"A t F ix Some.states.do not allow'exclfasiori or'limitatfon of incidental damages so these limitations may not'pf]iy to your <& x t: t ? v t �. Ft alco Firer�s,�r�'"-DG M�xa Yi Grooved Butterfly Valves, UL,.- ULC-Listed j FM Approved FireriserTl" DG Grooved End, Sizes : ".and 8"' 2. *1 1 f6 SpEc' ICATI'ONS, t A PrOssure 175 PSI (12.5 Bars) PSI (25.0 Bars) -WkW6ik FadprY lnstaited UL klsted-Dqu61e Tamper Use. t --S"OF IAL PRIMARY -VSTM A-536 Nylon -I 1 Coated Dik ASTIM A-536 EPDM Encapsufal Uvpqr,41 Lower Sit-nis A61,1120-SS �V'4im"Gear Shaft A181 410-SS :".146using -'AST,10 A-536 Hand ;lktheel -536 ASTNA A Flag Infrk;afor :AUM A" 536 Shear No 'ASTM'A-510 Segmctjt Ccai 13- 149 HotiMns, Gask6l FODNA Oradiuou O-Rings GXII) EPOR Grade'E' DU ENSION UNITANI(Mm) SIZE 'A B C D E F G H 7.112. 4,1(165) 13(85) 3.7(94.6) .2.q(73.0) 5J-(135) -44 3�6(?2) 1806A), 3.5(88 ?) 5 1;0' ijij 4' 77777- 1154 Z5) -5J(145)' 5,3(133.4) 6;5(168 3) 8.f3q16)1 '7.6(103), .8.90) Or W. 4.7(170) 5.8(147.7) &Wig -I) 94(232), 7,6(1.931) 4.9(125) 0.9(24, TradeMark p! FWalcp: Inc. Page 5 NORMAL PRESSURE DROP zs' L44S F3 3 NYMN Au gg- ggig (D W Ulf, At 1%3;A z4 C/) .00 CO PER, ""5 IMF C, oil 1, ISM U4 p LIS E R 0" Q 0* g Ol 10 10 C, [15RM 1 Z C, ton a SO 0, C> hi 00 'o WO irefty T.M BT & BG Brorue Butkernyr Vaives -. ?st tw 14jJ.3 er as i •'cF� ?";::vsv?. Mo 1s`.'�#'•yy tia S r' _�'• +'4 fS .:a:;i�:+ N- '�;, s-. -? •, . "'A`-,;.. w�, • r �ireNseriM � � NIA Ctit�'trory Bt�d�r Bu+t�er V�tves . _ ' % Y"j� .". t pF` ,•i�yY 9.uy - { +b.T" 2v .. 1 L _ • ) _ t ) L 1� iyFif�r`fer r�'t�my�oQw HM�L1''{� �i Y.ilLl Rf7✓1-L•�!"�■ •�F T.�c7 -i+.i.»ibi,. S'iA' /i'•7'§ R'liJ ��4Jyi�F"�4 4 i3+i�ir! i�t�ip. Waif (-� ' R ^{• 544W , . ": l : _4 h ^n"C �.> 4»r .. ,,73Y keys i.'}r dE &��f✓l "RRi� �•.1��`i��i�'itFi:�tc! "�i'���`�.4`i� �3'�d. it+`+��t i`}'Lta�" Crag ilw**6+i: f 4.c'3" Clue i i Three-way Bronze Valve, 1/4" IPS UL/ULC Listed* 300 psi Description The 1 /4" IPS three-way female threaded valve is 3 used to facilitate the installa- tion of sprinkler system pressure gauges. The valve � n and �7-2002 Firc�t�'ii3r�����ts�, f'�. two outlets. This design allows for replacement of the _ system gauge without shut- ting down the water supply to the sprinkler system. This design also allows Authoritys' Having Jurisdication to test system 1 ! pressure with an additional gauge through the second outlet. (The second outlet is normally plugged during installation with a 1/4" IPS - pipe plug.) U L/U LC Listed 2 R97 Installation Installation of the three-way valve can be accomplished with normal field installation tools. Make sure the valve is installed according to the flow indication arrow that has been cast into the valve body. The most common installation allows for a 1/4" IPS nipple between the valve and the water supply being mea- sured. This assures there will be adequate spacing for the sprinkler system gauge. Use either Teflon® tape or a suitable pipe thread sealant such as Pipefit Thread Sealant Paste with PTFE when installing the valve. DO NOT OVER TIGHTEN THREADS. OVERTIGHT- ENING MAY CAUSE VALVE FAILURE. Specs Size: 1/4" IPS Material: Body - Bronze Seat - Brass Handwheel - Iron Finish: Rough brass Working Pressure: 400 WOG For questions: 1 800 344-1822 1 800 344-3775 fax http://www.fppi.com info@fppi.com 1/2"-2" IPS Angle Globe Valves, UL/ULC Listed* 300 psi Fire Protection Products, Inc. 6241 Yarrow Dr., Suite A, Carlsbad, CA 92009-1541 L� Description Installation Manufactured from cast brass, Installation of the Trim/Drain our angle valves are for Trim or valves can be accomplished Drain applications and are using normal installation designed to be suitable for all methods. Use a suitable sprinkler systems including thread sealant such as high pressure systems. The PipeFit Thread Sealant soft seat design utilizes NBR with PTFE* or PTFE*Tape to Nancar N70 material for posi- assure a positive seal be- tive sealing to 300 psi. The tween the valves and the most common use for the 2" installed pipe. IPS size is as a system drain at the riser. May be used on Caution: Do not over - both alarm valve and shotgun tighten male threads into type riser assemblies. the valve body. Thread damage or craking of the *UL/ULC Listed, 2R97. valve body may occur. *PTFE is the chemical equivalent of Teflon® Teflon is a registered trade- mark of DuPont. Specs Materials Cast Brass: Body Bonnet Brass ASTM B16: Gland Holder Stem Washer Stainless Steel: Nut NBR Nancar N70 Rubberseat JIS FC20: Hand wheel Sizes: 1/2" IPS FxF 3/4" IPS FxF 1" IPS FxF 1 1/4" IPS FxF 1 1/2" IPS FxF 2" IPS FxF For questions: 1 800 344-1822 1 800 344-3775 fax http://www.fppi.com ©1996-2002 Fire Protection Products, Inc. TrimFit@ Bronze Globe Valve with Teflon* Seat, UL/ULC Listed 300.psi Description FPPI TrimFito Bronze Globe Valves are precision cast then machined using state of the art facilities. Each valve features a full floating seat holder for reduced seat wear when clos- ing the valve. Seat is made of pure virgin Teflon* for longer seat life and reduced mainte- nance as compared to rubber seat valves. TrimFit trim valves are suitable for use in regular (175psi) and high pressure (300psi) sprinkler systems. Standard configuration is FNPT x FNPT and is available in 1/4" IPS through 2" IPS sizes. Each valve carrries the UL Listing and is rated for use to 300psi. UL/ULC Listed 21197 Installation Install in accordance with usual and customary installation techniques for fire sprinkler systems. Use a suitable thread sealant on the male threads of the pipe being threaded into the valve body. We recommend either Teflon@* tape or PipeFito Thread Sealant Paste with PTFE. (PTFE is -the chemical equivalent of Teflon*) DO NOT OVERTIGHTEN. OVERTIGHTEW ING MAY CAUSE CRACKS OR LEAKS. *Teflon@ is a registered trade- mark of DuPont. PipeFit@, TrimFit@ are regis- tered trademarks of Fire Protec- tion Products, Inc. rcriecnaw atue��3 an. Specs Material: Brass or bronze Seat -Teflon" Hand wheel-JIS FC 20 painted red. Sizes: 06-798 1/4" IPS FNPT 06-8001/2" 06-802 3/4" 06-8041" 06-806 11/4" 06-808 11/2" 06-810 2" For questions: 1 800 344-1822 1 800 344-3775 fax http://www.fppi.com info@fppi.com ©2000-2002 Fire Protection Products, Inc. QUICK RESPONSE A UTOMATIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL - DESCRIPTIONAND OPERATION CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low - profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appear- ance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141 °C). • Water Working Pressure Rating - 175 psi (12 Bars). • Factory tested hydrostatically to 500 psi (34 Bars). • Maximum low temperature glass bulb rating is -67°F (-55°C). • Frame - bronze • Deflector - brass • Screw - brass *"Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm size. QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER TEAIPERATIIRF. RATIN(-,,/rT.ANNIFI("ATInN am-] In 1)R (rnn»vW. CLASSIFICATION AVAILABLE SPRINKLER BULB NARA. MAXIMUM TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY, is35F/t55°F5ro7°CE68°G k ORANGE/RED INTERMEDI YELLOW/GREEN S gt��'�}t5` t HIGH BLUE 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 JUNE 2003 A-20 BULLETIN GL5615, REV. #/5 Q UICK RESPONSE A UTOMATIC SPRINKLERS GL SERIES - UPRIGHT* PENDENT • VERTICAL SIDEWALL -HORIZONTAL SIDEWALL e CONVENTIONAL (OLD STYLE SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE *LENGTH FINISHES 2.8 (39 metric) 1/2" NPT . 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) **Satin Chrome Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester+ 7.8 (1 1 1 metric) 1 /2" NPT 2 1/4" (5.7 cm) Black Polyester+ 8.1 (1 16 metric) 3/4" NPT 2 7/ 16" (6.2 cm) *Lead Coated NOTE: METRIC CONVERSIONS ARE APPROXIMATE. APPROVALS * HORIZONTAL SIDEWALL IS 2 9116". FINISHES AVAILABLE ON SPECIAL ORDER. + AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. STYLE SIN K / 135*F 1550F 175'F 200'F 286'F cULus F.M. NYC - DOB MODEL FACTOR 57'C 68'C 790C 930C 141'C MEA 101-92-E GL2815 2.8 X X X X X X --- X GL4215 4.2 X X X X X X --- X UPRIGHT GL5615 5.6 X X X X X X X X GL8115 7.8* X X X X X X X X GL8118 8.1 X X X X X X X X GL2801 2.8 X X X X X X --- X GL4201 4.2 X X X X X X --- X PENDENT GL5601 5.6 X X X X X X X X GL8101 7.8* X X X X X X X X GL8106 8.1 X X X X X X X X VERTICAL GL5632 5.6 X X X X X X X --- SIDEWALL t GL8133 8.1 X X X X X X --- --- GL2826 2.8 X X X X X X --- X HORIZONTAL GL4226 4.2 X X X X X X --- X SIDEWALL § GL5626 5.6 X X X X X X X X GL8127 8.1 X X X X X X -- --- CONVENTIONAL GL5624 5.6 X X X X X --- -- --- (OLD STYLE) GL8125 8.1 X X X X X --- --- --- i HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6". ORDEPJNG INFORMATION f VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. SPECIFY UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. *112" NPT. Quantity • Model Number • Style GLOBE' PRODUCT WARRANTY • Orifice • Thread Sizes • Temperature • Finishes desired Globe agrees to repair or replace any of its own • Quantity - Wrenches - PIN 325390 (1/2"); manufactured products found to be defective in material or PIN 312366 (L.O.) workmanship for a period of one year from date of shipment. a For specific details of our warranty please refer to Price raa!♦ LORE List Terms and Conditions of Sale (Our Price List). t!!� FIRE SPRINKLER 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 CORPORATION 989-846-4583 FAX 989-846-923 I 1-800-248-0278 www.globesprinkler.com JUNE 2003 PRINTED U.S.A. BULLETIN GL5615, REV. #5 Inspection Managing co. -job name Conttact name --general name S1(02 )xxxx = 02 means WPB inspections in that drawer(s) No sticker on folder for month of inspection = annuals (semi annuals) Product Review Affidavit . St Lucie County, Public Works -Department Code Compliance Division �oR1pP P Lc�t zz, �(o -C Comw--trcto k CLr-*.L he following products will be installed in the structure located at tIT alu Building Permit # �.� r3.7 S I Owhers Name U, h c T'n!�51 Owner's Address Contractor Akre.,.s 66vn�t-eS Contractor's Address i4C.Ok K�c��-4•c fto�A I?c r-re, VL. 33403 Product *Product Rated I Manufacturer Model Number Method of Attachment Windows * Fill in the rated wind design pressures listed by the manufacturer for each product listed 1st Choice t,� A 2nd Choice or ppli.bw Fixed Glass 1st Choice t4 A 2nd Choice orvoicabie, Glass (other) J� Butt Glass Glass Block Tiding Glass Doors P4 1 A 1st Choice 2nd Choice cevsm=> Swing Type Doors 1st Choice +36 (4 X ZV OKr CzA CmAc.�or.: 2nd Choice cra�Wb,> 3��er ayt �o a•�. Overhead Garage Doors 1st Choice ercch -5 T3 8-0 2nd Choice ofappkbk) FL l ?'�- Sri-ea.��J`a,VAbe 4ba,.e �' 2.0 nnfina Material 4 ( t y a+1trs &*K- 3•'�ro�s� Asphalt/Fiberglass Metal l„ `( 5� a r-N 2-77 l r s ZG e . Other �x� s�• `g' Choice I have reviewed the above components and cladding, and have provide adequate resistance to the wind loads and forces specii Name: rDOn 6 • _VS0 1+V Ott AR t%i�ignature Design Firm r ei` g �.ce5 Cert. No. R..i.d bl].Ol dvt red their use'in'the structure to currc`rit code provisidAs. C�� 5O ".. � Date OFFICE USE ONLY: DATE FILED: 1/Z :5 REVISION FEE: PERMIT NUMBER: RECEIPT NO.: ST. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING & ZONING 2300 VIRGINIA AVE FORT PIERCE, FL 34982-5 2 ' .462-1553. AA y op APPLICATION F ..,P, BUILDING PERMIT REVISIONS PROJECT ENFOR-NIATION, LOCATION'!SITE ADDRESS: 7-ZW- 2. DETAILED DESCRI 'REVISIONS: L12 .3. 4. 30 No 10-SS OF PR9JECT to- +9-h ke rc eA- CONTRACTOR INFORMATION.: ST. OF FL REC;./CERT# 5;doC- -0 BUSI-NESS,N.%-NIE: . Ak t-�S Qualiriers'%ame: ADDRESS: CITY: c earpa PHO.NE'(D. V\ - I NAME: ADDRESS: CITY: PHONE (DAYTI.NIE): c- a I-c' 1'e ST. LUCIE COUNTY CERT.` STATE: ZIP: U ?N-CM4- FAX# a. O rC Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 24 January 2007 Job Address: 7397 - 7407 COMMERICAL CIR Received By: counselb Paid With: CK Paid By: ALLAN R BALL OR MARIE A L BALL Sign: Receipt#: 0000050273 'ermit Number: SLC- 0608-0334 Amount: $550.00 2redit Card Number: Check Number: 2296 OFFICE USE ONLY: DATE FILED: REVISION FEE: SD a -GD PERMIT NUMBER: S�- - -6609 —6 RECEIPT NO.: ST. LUCIE COUNTY DEPARTMENT OF COMiMUNITY DEVE] BUILDING & ZONNG 2306VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 .462-1553 APPLICATION FOR BUILDING. PERiVIIT -R PROJECT INFORMATION 1. LOCATION!SITE ADDRESS: 2 DETAILED DES REVISIONS: f PTIONS OF -PROJECT A<1c K.;q1 l Ci f-G( -e- '4 orOC- i ps 7 ko._-A tP-30.IA Seer e.�y .s-- ( 3 t 3o3�3oS of bl.;TOI w5z F-017-P, CONTRACTOR INFORMATION: ST. OF FL REG./CERT# G O�SI ST. LUCIE COUNTY CERT.» BL"SINESS N.��IE: Qualifiers Name:' I ADDRESS: •e b CITY: ►L STATE: (� ZIP: j OK PHONE (DaYTI}IE): .. p FA_Y # S6 I ARCH IT/EN GENE E R- 1 I\ANIE: ADDRESS: t e t CITY: STATE: ZIP: - 'PHONE (DAYTIME): r pC,f' FAX#