Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSFee Due: Receipt# Permit # Lid OL' St. Lucie County.Building & Zoning 2300.Virginia Avenue Ft, Pierce, FL 34982-5652 S'L'���E % Tel. 561-462-1553 BY SPEC°IALTY PERMIT APPLICATION St' Lucre County ❑ Electrical ❑ Plumbing ❑ HVAC , ❑ Fence Shed. ❑ Demolition ❑ Gas ❑ Siding Seepage 2 for instructions and additional paperwork required for specialty permits 1. Location/Site Address: y90 61 L 60 /0 r"C5 G z/LG L F % %/ I✓ Z 6-466 2. Parcel -ID Number: Office Use Only% Section rowns.hili Ra.n a `map Page Zoning Land Use.. Initials 1 3. Description of Project or Work Activity: P L. yc �rA✓4- a F $ h► Ed C��1.CF�13 5MX7#0-ref 10Xly) /bO el-R-TArC 4. Owners Information Name:. _r6W % L = . -nO Address: 1?901 P,4L974> PZrvE5 L 774• City: r T, Pr &Z Le State: C. Zip:. 31195 % Phone: (-3 y63 5. Contractors Information FL Reg/Cert #: County Cert#: Business Name: Phone Fax _ 6. Value of Construction: CN— OWNER'S AFFIDAVIT: I certify that" all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. 70/yt C T 77 L E PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER STATE QF FLORIDA, COUNTY OF 1 144 J ACKNOWLEDGED BEFORE ME THIS DAY OF 2&BY WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED S TITLE: NOTARY PUBLIC NOTARY St. Lucie County Specialty Permit Application rev. 8/25/05 drag AS IDENTIFICATION TYPE OR6M NA EM OF�NOT�A( t (r (seal) COMMISSION NUMBER �QE1 00 � 5 .515 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE .OF -COMMENCEMENT MAY RESULT, IN YOUR PAYING TWICE. FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C -HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. INSTRUCTIONS Please complete all information in the space provided. All information must.be printed (use black or blue ink only) or typed, This permit application is to be used only for those activities that are not otherwise included under a primary building permit. This application may not be used for any activity that includes structural alteration. The information to be provided with this application includes: 1. Location/Site Address 2,.,Parce.1JI) Number 3. Description of Project or Work Activity Indicate the street address or general .location of the property where the building activity is taking place. Indicate the tax identification number of the property 'where the building activity is taking place. Fully describe the activity to take place. 4. Owner Information . Indicate the name and address 'of the owner of the property on which activity' is taking place. 5. Contractor Information Indicate the State of Florida registration number (if applicable), St Lucie County contractor license number . and 'the,name' of the `business doing. the Work: 6. Value of Construction Indicate the total value of the work to take place. Total cost of construction includes all current retail material and labor costs associated with the building/construction activity. Construction value is used to determine the,permit fee. St. Lucie County reserves"the right fd question and/or modify the indicated,value-of:construction if it is.demon.strated that the submitted..f gures are not consistent with. similar types of constructi'dn`, " ❑ Gas Attach 2 piping schematics with•iank size; location, and BTU of'each appliance ❑ Shed: Attach 2 plot plans, 2 copies of DCA letterand plans,'2 anchor specifications ❑. Fence Attach 2 plot .plans showing location offence height of fence and type of fence ❑ Siding Attach 2 copies of manufactures specifications ❑ HVAC Attach 2 residential energy studies, 2 manual J calculations. 2 sets of duct layouts for new system or full replacement This application can be submitted.to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. NOTE: Emergency electric service change out inspections will not be performed after 3: 00 PM without special arrangements and additional fee paid. Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261. St. Lucie County Specialty Permit.Application rev. 8/25/05 dmg �JC`E COG ST. LUCIE COUNTY BUILDING & ZONING . � Y �_ 23DO VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 F�ORI�P 462-1553 FILLED LANDS AFFIDAVIT I, the undersigned, am the owner of the following described property: I9IL1 9-P144co 1J;0sNE5 G.riZcc for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number , I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this property, St. Lucie County -is neither obliged nor liable to provide for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. 7 oXTi(-oL-3-0 Property Owner Name Property Owner Signature Date STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS DAY OF 20 BY SIGNATURE OF NOTARY NOTARY PUBLIC TITLE WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED IDENTIFICATION. TYPE OR PRINT NAME OF NOTARY (SEAL) COMMISSION NUMBER �UNS� �6g35 gpF\6 �M\SS\O� e2 2� coe`5 St..Lucie County.: . - - Building' Lontig Department O _ 23G__ :.rginia Avenue Fort Pierce, Florida 3-4982 (772) 462-1553 OWNE%BUILDER AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTION'S State law -requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, -as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct. on -site supervision of the construction yourself. You may build or improve farm outbuildings, a one -family or two-family residence or a commercial building at a cost of under S254000.00. The building or residence must be for your own occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a building you have built or substantially improved your self within one year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease. +,.-hich is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Initial "! C. I understand that the building official and inspectors are not there to design or give advice on how to meet the minimum code. Initial ?� 1 understand that as an owner -builder that any contract disputes with sub -contractors and I must be handled in a civil court with the advice of an attorney. This department will not.mitigate any contract disputes. Initial I understand that if I compensate any person or- company for work performed they are required to be licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and liable for the cost of the license. Initial TL- I understand that if any person that is unlicensed and uninsured gets injured on my construction project - they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and related medical cost, which could include loss of wn oPs during recovery from their injury. Initial L To qualify for this exemption under this subsection, an owner must personally appear and sign the building permit application and initial the above. l hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owneribuilder exemption shall be reported by the Building and Zoning Department to the Florida.State Department of Professional Regulation. Signed and acknowledged on this day of ,9A2r(- of 20 & 7. OwnrllKuilder Signature STATE OF FLORIDA COUNTY OF The fore`oine instrument was acknowledged before me this who is personally known Signaturc of rota-•.= Title: N%'%,a , Public as identification. Tvpe or Print tame of Notar v Commission Number day .of 20_, by to me or who has produced ��uNo I�5 M`1 �,�Q�NEN �NpuO��c OpOdeam ')30 --PAteo-plVe8 _Clot ROW ROW PgLEp PINES CIRCLE 60 R/W 20'ASPyALr 0 0 � I C7v ' o \ UP FIR 1/2 49.S�85 90 26' 1 p,,E 20, PARKWAY R= 0 FPL I (P) 49 gp,(M) LC4 40230'01�9,1 0.601(P) I 4p 65`( L CF ) ® CATCH FND BASIN CONC I M I U) �� MONUMENT FIP 1/2 LOT 329 k f ^v CONC Lri W/MI`) DRIVE i 17.10, I LOT 328 O J 20.10, COA/C I PORCH 0.16' ,y `n I ILOT 327 NSIDE *-r „ _ r\i 38.90, I � 4909 01 A/ ONE STORY RESIDS CIRCLE I N O CONC o SIDE M •�+ c I u) N I O 7.43' 13.50' • o I � Lli 20.05' � COREENED 0 NC pq710CD \ M ,-r POOL M ON C NC POOL O w 0 �C O ti I� I J / 2 — — — — - - — — — — — — — — — — — — — — — 10' U.E. 7.46' INSID S89031'16" 100.00'(P) 90.90'(M) FIR 1/2 FIR 85' D.E. (P) 1/2 Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stlucieco.gov/ce Date: 23 April 2007 Job Address: 4909 PALEO PINES CIR Received By: counselb Paid With: VS Paid By: TONY B LITTLE Building Receipt Receipt #: 0000053373 'ermit Number: SLC- 0704-0420 Amount: $82.40 Zredit Card Number: XXXXXXXXXXXX1042 Check Number: Sign: ��ufiGGz l/O�S� Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce Issued: 04/23/2007 Conf #; 814 Job Location: 4909 PALEO PINES CIR Permit Type: Shed BUILDING PERMIT Page 1 Permit #: SLC- 0704-0420 City: FORT PIERCE Job Description: INSTALL NEW TIE DOWN FOR 1OX14 SMITHBILT PRE -MANUFACTURED SHED LOCATED IN Subdiv: Holiday Pines S/D Phase IIB Lot: 328 Block: Owner Builder . ANTHONY B LITTLE 4909 PALEO PINES CIR Parcel: 1312-801-0131-000/7 FPR, FL 34951-2384 (772) 201-3463 Property Owner JANICE R LITTLE 4909 PALEO PINES CIR FPR, FL 34951-2384 Setbacks Left: Right: 35.00 Front: Rear: 20.00 Zoning: RS-4 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: Flood Zone: Elev: Job Value: $ 2,499.00 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Raymond Wazny Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. "rGiP� GO,ttot.� .e• Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce Issued: 04/23/2007 Conf #: 814 Job Location: 4909 PALED PINES CIR Permit Type: Shed BUILDING PERMIT Page 1 Permit #: SLC- 0704-0420 City: FORT PIERCE Job Description: INSTALL NEW TIE DOWN FOR 1OX14 SMITHBILT PRE -MANUFACTURED SHED LOCATED IN Subdiv: Holiday Pines S/D Phase 1113 Lot: 328 Block: Parcel: 1312-801-0131-000/7 Owner'Builder ANTHONY B LITTLE (772) 201-3463 4909 PALEO PINES CIR FPR, FL 34951-2384 Property Owner JANICE R LITTLE 4909 PALEO PINES CIR Setbacks Left: Number of Units: 1.00 Minimum Floor Elevation: Job Value: $ 2,499.00 Right: 35.00 Front: Floors: 1 FPR, FL 34951-2384 Rear: 20.00 Buildings: 1 Flood Map: Flood Zone: Zoning: RS-4 Square Footage: 0.00 Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Raymond Wazny Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. 3TA:TE aF FLOR10A DEPA,R..REU.T...QF.-.GQUN[URLTY AFFA[RS�;r 'Dedicated to' Okirrg Ficrrda a better place to cal; home•' s atu* . - r oEus L_ =60C-= �----- 41W Certification Number: N=T 209 Smithbiit Industries, Inca Address: 1061 Mchway-92 west Florida 3=. Expiration: November 06, 2007 Commercial -and storage -Buildings-- This will confirm that Smithbilt Industries. Inc. is -unified to manufacture manufactured (modular) buildings, as defined by Rule Chapter 9B-1, FAC, and Chapter 553, Part I, FS, For location or sale in the State of Florida The condition of this certification is. . •.sated to anrhori2ation specified in the above references. Each building shall bear a: S tare ' nsignia located on the electrical panel box cover. This certification renewal shall be for a Period of three years, as indicated above. The mantnaca= willreceive-a,renewal notice l y E-mail, generated by the Building Code lntormaison System (BCIS) 90 dad s pror to expiration_of this rot+.ce. The manufacturer must S-uomit the information required in s. 553.381 F.S. and Rule Chanter 9B-1.007 FAC online at www..floridabuilding.org. if you have questions regarding licensing requirements for site -related permits for installation of manufactured buildings, you may contact - U'S,- your local building department or the Department of Business and Profession Regulations at (950) 487- 1395. Sincerely,, 1.1 i � � f � ��•,� i Michael D. Ashworth Program Manager Bui�Piogram Building Codes & Standards: , Phone: 850-9n-5075 FAX 850r-414-84 .6 . ......... ... — 7FT5 SHUWARD 0,[X—WIDULEVAR- TALLA4A3'SEE, FLORtOA, SZ399-2-100 Phone: 85a•.488.6466/Suncom 278.8486 FAX: 850-921.0781/Suncom Z91.0781 intarnet address: htta://www.jca.s(ate N j3 cwrrcx =-m cow= e1 now Orr= 0000A TY MANN O 098100 r wwhaarrr Houai+a a OOMMlAfrY oe AR ArIDE(T 27" O*+ ) Go mww, 3uft Z12 296 ShLwA r 0" 8061WArd 25" ShLOFA O Ore BM*FMM 25" VW0604 Ott SMAN ra �wess rL Trrfr� RSTIDG Z10d Td.rrwft FL32305 210a Ti &MMOM F137]M-Z .. Ioam"A'7m" - Project No. 0 Scptember 15, Pro oct; J Szr�thbilt Portable.B.ui.ldings McCarthy Engineering, Inc, has .been askod by Mr. Sam Waters, owner of Sam at Tlxnmans retail aalee company for Smithbilt portable buildings, to review your conccm for using overhead doors for the single wide buildings, Your master plan file for single wide buildings, project number 0 113 1, have been designed for the addition of an overhead door in the side or erid of the building. 'Ihe framing is the same or similar to the,doors in the double wide buildings. Should you have any questions eoncecning the structural enginccnnj review or need further assistance, please do not hesitate to call our office. Sinc=ly yours, McCARTHY ENOINEERINO,.INC. William J. McCarthy, P.E. Florida Repstm don No. 2,M6 Special Inzpoctor No, 159 WJM/jmk CC: Kea Smith — Smithbuilt Industries, Inc. TO; ►�. ` Q r Sam Watmre — Sam at ' Th.crmans A FROM' X DATE AQES THURMANS OF FORT PIERCE INC SAM H. WATERS t--�`Q 9._0. � �.J�QN ;-2775 N. US HIGHWAY 1 FORT PIERCE, FL 34946.8924 ' 772.464.4077 e..,. 1 r u SMITHBILT INDUSTRIES, INC. PORTABLE BUILDING ANCHORS BUILDING ANCHOR SCHEDULE BUILDING SIZE NO. OF ANCH. @ EA. -END OF BLDG. NO, OF ANCH. @ EA. SIDE OF BLDG. TOTAL ANCH, PER BLDG. 8',10',12'&14' WIDE TO 24' LONG 2 - 4 48' 2 1 6 50' 2 2 8 20',22'&24' WIDE TO 24' LONG 4 - 8 48' 4 1 1 10 50' J. 4 2 1 12 BUILDING ANCHOR DATA MODEL NUMBER LENGTH BAR DIAMETER EYE DIAMETER HELIX DIAMETER UPLIFT CAPACITY IN NORMAL SOIL 36SHE34 30" 1 /2" 1 1 /2" 4" 2500 lbs. NOTE: THESE ANCHORS MEET THE WIND REQUIREMENTS OF THE FLORIDA 2004- BUILDING CODE AND THE AMERICAN SOCIETY OF CIVIL ENGINEERS STANDARD CODE ASCE 7-02. WIND LOAD: 150 MPH BOLT THRU ANCH. & 2x6 SKID OR HEADER BEAM w/8"0 x 4" LAG BOLT SKID (TYP.) w/n"x2"w WASHER SIDE ANCH. DBL. WIDE ONLY .f----------------�. •I I — I END ANCH._ ' ANCHOR SPACING PLAN .,. HELIX TYPICAL ANCHO A`to/* ; SCALE NONE I DATE I LOCATION OF JOB A MCCARTHY ENGINEERING, INC. PORTABLE BUILDING ANCHORS DRAWN BY D4 6 27 03 ANYWHERE FL m STRUCTURAL CONSULTANTS LAUCLAND, FLORDA SWCLE AND DOUBLE MDE BUILDINGS C)7EOCED BY W.J.M. 6 27 03 2225 CAST EDCL9000 DR1i SUTE A - LAKELAND. FL JJ60.J $A1ITHBILT INDUSTRIES INC. CKECNED BY PROJECT NO. PHONE (663) 657-1752 • FAX (963) 667-1790 CCRMCAIE !Y AUTHORIZATI N Na 6394 A RN A FLORI A 02030 1YLbm J Nc-., P.E. 2NS5J WG NO]A-T Ev ' > ' x.*=pmv—^ L_�-..~~__. . � ' aarmwimem UIF CAW MNr ,~jow*w-_---_-__-_ wmw*smm 7.6 (TM * EACM A" APPROVE WNIAWJWrMPASS Z.4Wr#tAJE(nP Zr XWAdr RATE IN nvw WADE JWW AV QWMrSANl