Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS1� jNUMMERDATE FILED- ECEPLAN REVEVY FEE- RTNO0 W�7PERAUrIPT CT- CAI_ NO-: FEE R CONCURRENCY /: v>>ll �/% -• Lam,//% / ALL I-1F0 MUST BE COMPLETE. ]FILLED IN TO BE ACCEPTED �G�E CpGy ST- LUC1E COUNTY PUBLI.0 WORKS ' BUILDING & ZONING DEPARTMENT Sc 2300 VIRGINIA AVENUE : � • � VA FORT PIERCE, FL 34982-5652 - `U�, �2 ORt�Q 772-462-1553 I� G'o APPLICATION for BIMDING PEPJMT CERTIFICATE of CAPACITY/ZONING C-ONIPLL NCE PROJECT INFORMATION 1 _ LOCATION/SITE ADDRESS:vt JJ`T 1 � _� �'` l�()Ly Z) y j 2 _ SID NAME: �Ql YYl �� Z�S � Lk6 SITE PLAN NAME_Vez m Club 3_ PROPERTY TAX lD#: 01 IO � O_da CCIO 4_ LEGAL DESCRIPTION (attach exha sheets if necessary)_ �O� a� oCY 9- --?alm 13 ct ez-a5 oo 4q a �3 ecav-A5 -S+. Lue►eC.oursty.. 5_ PLATNO- BOOK Q 6_ PAGE- - 7_ BLOCK 8_ LOT BOOK � {- NO_ Z -� NO_ _ 9- PARCEL SIZE_ ACRESISQ FT_ V LOT DIMENSIONS /y I ,� ID 1 1 O_ DESCRIPTION OF CONSTRUCTION PROJECT OR WORK ACTIVITY_ 11_ SETBACKS (ACTUAL) FRONT: ( BACK: ( A KIGH SIDE 12_ TYPE OF CONSTRUCTION (Check all;approp—riate boxes) Dq - NEW CONSTRUCTION [) p(PANSIONIADDITION RESIDENTIAL [) COMMERCIAL j ] OTHER (SPECIFY) + LEFT Q + ;,y SIDE: U� [ ] INTERIOR RENOVATION [ ] INDUSTRIAL 13_ DESCRIPTION OF PROPOSED USE ► - u 14_ Sq- FtJCONSTRUCTION: Sq_ Ft 1st Floor_ 16. VALUE OF CONSTRU"ON: $ 8 2� The value of construction is used to detemvpermit fees the amount of perfees to be assessed_ St_ Lude County reserves the right to question ae: vah rrrod� the i ced value of=conslnrEtiorrif is dernonstrated3l►atttse subrrat%d s are not cc tl tentvsn-th slmaar types of construction activities_- if tiie � S26a or mote, a RECORDED No5ce of Comrnencemeni must be submitted voth Ns application_ E LCCDV Form NO_: 001-02 OWNER-10FORMATION: sAN1E: ten- � 13m s ADDRESS: :p�' � CITY: 1JtJ�W tDV% _ E! 0,C STATE: Tl Z]P: 3342/� P}IONE-(DAYTIME)_ W) 53(6 - 100.0 IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW_ FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZP Pi-iONE (DAYTMAE): CONTRACTOR INFORMATION ST_ of FL REGJCERT il: BUSINESS NAME: Cknj QUALIFIERS NAME: C -' (D ST_ LUCIE COUNTY CERT #: �/ 1 ADDRESS: + CITY: �`.I Yt�� Y1 - T STATE: - ZIP PH0 E(DAYTIME): • . (W{l 536- [ til(6 ` FAX140__561- 5-3b- tID-70 ARCHITIENGINEER: ADDRESS: CITY: PHONE (DAY-hME): BONDING COMPANY: ADDRESS � - CITY: MORTGAGE LENDER: ADDRESS: Cm: _6 Q E� W A K E-t-1 G I Iy E R INC (! 600 �sn l' I X IE �Ic'IAWA STATE: _ 73P 601 39a- 3748 STATE: STATE: ZIP Z)P after iiot-sfscation it will be voided and retui iiei Ito. -V0 i jV 'mail. STATE OF FL RIDA COUNTY OF vl -The foregoing instrument was cknowtedged. before me thisr�� day of ?' j ; 20T, by Dave Al? ratK►5 who is personally known to me 4a4lvfe's o hapro ced as identification_otary 'IvO Tory a McDorid f— T e Print Name of Nota t',sion # DDT 5265 6 �� - A '''� Type of Print Name r. of Nola Expires: JULY :t9, 2009 Notary Public Title �ynd�H Thru Acldn�c Bonding Ca., Vie. Notary Public Title CERTIFICATION: This appiication is hereby made. to- obtain a permit' to -do the work and, installations as indicated, 'and -to obtain a certificate of capacity, if applicable, for the permitted work 1 certify that no work or instbllation has commenced prior to the issuance of a permit and that all Work will be performed to meet the standards of all laws regulating construction in this jurisdiction_ I understand That separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATEkS, TANKS, AND AiR CONDITIONERS; ETG_, not otherwise.included-with this building permi(�Spplication_ The following building permit applications are exempt from undergoing a full concurrency review=- room additions, accessory _ structures (all types), swimming pools, fences,valls, signs, screen rooms, utility substations& accessory uses to anot residential use_ her non NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY_ iF YOU INTEND TO OBTA)N. FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT_ - NOTICE TO APPLICANT_ AS THE APPLICANT FOR THIS BUILDING PERMIT, iF IT IS NOT YOUR RIGHT TITLE :AND INTEREST THAT iS•SUBJECT TO ATTACHMENT- AS A CONDITION OF THIS PERMIT YOU PROMISE 11\1 GOOD -FAITH TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION -LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY ISSUBJECT TO ATTACHMENT_ OWNER'S AFFIDAVIT_ I certify that all the foregoing information,is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning_ OV,V-VERICONTRACTOR SIGNATURE CO RACTOR SIGNATURE STATE'•OF COUNTY 0 U� i The foregoing- instrument was (acknowledged before11M me this- day oE.� 20�, by Qj�� who is personallyn to me orWho•- A--- TARY PUBLIC -STATE OF FLORIDA NOTARY PUBLIC -STATE OF FLORIPA Toilya McDomdd Commission # DD452656 Expires: J LY 19,. 2009 lPentItld T14U AtIMUIC Bnaelln$ Go,, ine: -Commission- Number Commission -Number (seal) - (seal)' NOTE_ TWO (2) SIGNATURES ARE REQUIRED_ EACH SIGNATURE MUST BE NOTARIZED - IF APPLYiNG FOR THIS BUILDING -PERMIT AS AN OWNERBUILDER, THE OWNER MUST PERSONALLY APPEAR TO SiGNTHIS APPLICATION iN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION" Bp:g: 070 . . . . . . . . . . . . . . . . . . . -- -_------------------ -TOVMS RANGE ' 1 42 t . MAP NO.- C LAND USE LOT CVG TAZ NO.: ZONING: MAX HGT- FIRM MAP lSTFLREI_V-.. FLOOD ZONE- OCCP TYPE: MA)C O0CP- OF FLRS: CST TYPE: WATWATERSEV%fER- 11 r1o114 SPRINKLERS STORMVVATE R LOT OF REG (beir I/M LOT OF REG (attr 1190) LOT -SPLIT RE' LOT SPLIT APPRVD LIBRARY]PARKS IMPACT FEE PERMIT FEE DECAL IMPACT FEE NUMBER -2zl Y HABfTABALE RADON FEE REPORT /o/ PUBLIC BI:DG IMPACT FEE AREA CODE (RADON) GROSS ROAD Y CREDIT TOTAL ROAD ROAD ZONE IMPACT FEE � lQ 0 IMPACT FEE IMPACT DUE. . . . . . . . . . . . Y_ SCHOOL- CREDIT SCHOOL FEE WFACI pOUCEFEE <7 2 FIRE FEE MISGFEES: TOTAL POUCEIF)REI MISG_ FEES y N TOTAL ALL A,DDMONAL SPECIFY: FEES V PERMITS RE(YD. PLANS.. - EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT - SAINT LUC77--70UNTY FILE # 3045353 OR ,`,)K 2804 PAGE 2027, Recorded 04/24/2, at 12:26 PM Return to: Centex Homes 3301 Quantum Blvd. First Floor Boynton Beach, Florida 33426 NOTICE OF COMMENCEMENT This Instrument prepared by: Tonya McDonald Address:3301 Quantum Blvd. First Floor Boynton Beach, Florida 33426 Identification SPACE ABOVE THIS LINE FOR PROCESSING DATA SPACE ABOVE THIS LINE FOR PROCESSING DATA ermit No. NOTICE OF COMMENCEMENT of Florida v of St. Lucie The undersigned hereby gives notice that improvements will be made to certain real property, and in accordance with section 3.13 of the Florida Statutes, the following infromation is provided In this NOTICE OF COMMENCEMENT. :gal description of property (include street address, If available) it 2. Block 9. Palm Breezes Club, according to the plat thereof as recorded in Plat Book 49, Page 32 9334 Treasure Coast St., Ft. Pierce General description of improvements: Single Family Owner Centex Homes Address 3301 Quantum Blvd., Boynton Beach, Florida 33426 Owner's interest in site of the improvement: Fee Simple Title holder (if other than owner) Name N/A >ntractor Centex Homes (dress 3301 Quantum Blvd., Boynton Beach, Florida 33426 irety N/A (dress Amount of Bond $ iy person making a loan for the construction of the improvements: ime NIA (dress NIA !rson within the State of Florida designated by owner upon whom notices or other documents iy be served as provided by Section713.13(1)(a)7.,Florida Statutes. Ime Mike Reynolds [dress 3301 Quantum Blvd., Boynton Beach, Florida 33426 addition to himself, owner designates receive a copy of-the-L'1di piration date of Notice of itless different dates Lewis Birnbaum NOTARY RUBBER STAMP SEAL NOTARY PUBLIC -STATE OF FLORIDA Tonga McDonald I Commission # DD452656 MW Expires: ARY 19, 2009 Bonded Thru A,antic Bonding Co., inc. ice as provided in Section 713.13(1)(b), Florida Statutes. icement(the expiration date is 1 year from the date of record - STATE OF FLORIDA ST. LUCIE COUNTY TRUE THIS TO CERTIFY THAT THIS IS A ORIGINALAL. CORRECT COPY OF THE , CLER Date: Lewis Birnbaum Division President I have relied upon the following Identification of the Affiant who is personally known S rnto and subscribed before me this A ril 23, 2007 I otary Sign ture Tonva McDonald Printed Notary Signature RESIDENTIAL/COMMERCIAL BUILDING PERMIT CHECKLIST Site Location:�Q Permit Number: _ Technician: General: 11*,0" Application completely filled out with notarized signatures s No N/A Sub SummaryList with contractors' names and count & state Y �} "" Ye No N/A certification numbers Sub Agreements with original si natures gg `� 000l Yes � No N/A Owner Builder Affidavit ❑ Yes r-1 No r N/A Owner Builder Electric Affidavit s No N/A Filled Land Affidavit r No N/A Geo or recorded warranty deed �s No N/A Recorded Notice of Commencement "` Yes No N/A Utility Agreement or Payment Receipt No N/A Vegetation Removal Permit [�A�es Yes Ci No C N/A Non Conforming Lot of Record Yes No ❑ N/A Plans. Calculations & Attachments (3 copies commercia1/2 Complete set of plans with engineer/architect raised seal Truss plans reviewed and approved by engineer/architect Landscaping and parking plan 3 Copies of approved site plans 2 Sealed surveys or plot plans with dimensions, finished floor elevation and setbacks Health Department approval stamped on survey and floor plan. Health Department food establishment permit stamp on floor plan Manual J or Manual N calculations Signed Energy Calculations Sealed Wind Load Compliance Certification Product Review Affidavit .wend : Ye r No 7 Yes El No C C Yes ❑ No 0 E-j YY r No � Yes No N/A N/A N/A N/A N/A C Yes 1=J No C N/A C s r No r N/A '-' es r No N/A Y s r-s No N/A No N/A Yes r Nor N/A Page 1 of 2 R F. WD F, ATHA LICOHHERCIA L B UILDING PERMIT CHECKLIST Site Location: Permit Number: O_...�-_, Other: Health Department permit paperwork CD for Fire Department if commercial or multi -family DEP, SFWMD or Army Corp of Engineers Pool Barrier Affidavit Ground sign landscape affidavit Burn rate for sign cabinets RV and Mobile Home Tie Down Only (2 copies): Permit Worksheet (Tie -down diagram) Manufacturer set-up and installation manual Manufacturer blocking diagrams Signed penetrometer test (1 copy) Stair details Mobile home inspection report for relocation Copy of Title for relocation Comments: Name: ignature: Technician: --' ---. - - 'SS e�t=n Clear Form C Yes r No r N/A r Yes r No ❑ N/A Yes No N/A C Yes ❑ No r_1 N/A G Yes ❑ No ri N/A U Yes ❑ No 0 N/A r' Yes U No El N/A G Yes r No Cl N/A r Yes El No U N/A Yes l No ❑ N/A Yes 11 No ❑ N/A F '' Yes, r No Oj N/A Ell Yes ❑ No r N/A Page 2 of 2 -7 y yY cj HomeTeam PEST D EFF H SF New Construction Subterranean Termite Treatment RECAOCT J Public Work, St. Lucie County, f'L This report is submitted for information purposes to the builder on (new) construction cases where treatment for prevention of subterranean termite infestation is required by the Florida Building Code, Section 104.2,8. All contracts for services .,are .between the Pest Control Operator and builder,. unless, stated otherwise. Section 1: Hometeam Pest Defense Company Address; 4356-A Fortune Place City: West Melbourne State; `FL 32904- Zip 1532 Company Phone No.: 321-409-8489 Business License No.: JE20424 Section 2: Builder Information Company Name: CENTEX HOMES - SE FLORIDA DIVISION Phone No.: 561-536.•1000 Section 3: Property Information Building Perr7ill No.: _ Location of Structures) Treated=t933d TLREASiJIIE' COAST 5T� F,e?RT L O' Q4 2 O'70'Y Type of Construction: Z Slab ❑ Basement ❑ Crawl I -I Other Approximate Depth of Footing: Outside: Inside: Type Fill: 13I131 Section 4: Treatment Information Date(s) of Treatment(s): 10/08/07 Brand Name of Product(s) Used: Probuild TC EPA Registration No.: 100-1006 Final Mix SOIUtion:.5 Treatment Area Sq. Ft.; Linear Ft. 210 Linear Ft. of Masonry Voids: Total Gallons of Termiticide Applied: 42 Service Agreement Available? E Yes ❑ No This building has received a complete treatment for the Liquid treatment: EYes ❑ No prevention of subterranean termites. Treatment is in Liquid Final exterior treatment: EYes ❑ No accordance with the rules and laws established by the Borate treatment; ❑ Yes ® No Florida Department of Agricultural and Consumer Bait in lieu of Pretreat: 17 Yes R No Services. Initial Note: Some state laws require service agreements to be issued. This form does not preempt state law. Attachments (List) Comments Name of Applicator(s): AKEGAN Certification No. Authorized Siynature Date RH-NT()/q5 F9264 10109/07 Z abed 08Z6£ZLLZ£ OZ:£Z LOOZ'90 100 This Certificate is issued pursuant to the requirements of the Florida Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of St. Lucie County regulating building construction or use. For the following: Building Permit No. - Q070' °� Parcel/Folio Nbr: 2310-500-0158-000/5 Lot # 2 Block: 9 Subdivision: Palm Breezes Club Occupancy: Residential - 1 & 2 family dwellings Building Address: 9334 TREASURE COAST ST Legal Description: PALM BREEZES CLUB BLK 9 LOT 2 . Permit Job CONSTRUCTION OF NEW SINGLE FAMILY RESIDENCE - 2/2.5 Description Permit Finaled: 10/08/2007 Contractor DAVID ABRAMS CENTEX HOMES 3301 QUANTUM BLVD BOYNTON, FL 33426 Christopher Lestrange Building Official (561)536-1000 Monday, October 08, 2007 Date Printed NOTE: This Certificate of Occupancy is issued to the above named, for building at the above named location only upon the express provision thal the applicant will abide by and comply with all the conditions of the Zoning Ordinances and all Ordinances or Building Codes of Saint Lucie County pertaining to the erection, construction or remodeling of buildings or structures. This also certifies that the electrical wiring and/or equipment, and the plumbing work have been inspected and approved. The issuance of this Certificate grants permission to occupy and use the property described herein only for the use indicated. Any change in use will require a new Certificate of Occupancy. POST IN A CONSPICUOUS PLACE Professional Insulators of the Treasure Coast FTC Insulation Installation Certificate I SEP 1 t 2007 To: St Lucie Count Date: August 24, 2007 00 7-040444 0 loek: 02 Address: 9334 Treasure Coast Street Project: Mornm side The undersigned hereby certifies that insulation has been installed in the above described property as follows: 1. Exterior CBS walls have been insulated with: Spray -on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Fi Foil Rock Wool Blankets Density: X Aluminum Foil R-Value: R-4.1 Rigid Board Polystyrene Other Exterior (frame walls) have been insulated with: Spray -on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Rock Wool Blankets Density: Aluminum Foil R-Value: Polyurethane Other 2. Ceilings (level) have been insulated with: Spray -on Cellulose Thickness in inches: 8.3" lFiberglass Blankets Manufacturer: Green Fiber Rock Wool Blankets Density: Fiberglass Blown R-Value: R-30 X Cellulose Loose Fill Other Ceilings (Inaccessiblel) insulated with: X Fiberglass Blankets Thickness in inches: 10" Fiberglass Loose Fill Manufacturer: Johns Manville Rock Wool Density: Fiberglass Blown R-Value: R-30 Cellulose Loose Fill Other 3. Interior kneewalls have been insulated with: Fiberglass Blankets Thickness in inches: Rock Wool Manufacturer: Polyurethane Density: Spray -on Cellulose R-Value: I 10ther 4. Garage partition walls of A/C living area have been insulated with: ( Rock Wool Blankets Thickness in inches: 3 5/8" X Fiberglass Blankets Manufacturer: Johns Manville Aluminum Foil Density: Polyurethane R-Value: R-11 Other 5. The following have been insulated: CBC1254039 Competency # CENTEX HOMES Professional Insulators of the Treasure Coast General Contract/Builder Insulation Contractor 'L St Lucie County Inspections 2300 Virginia Avenue Ft Pierce, FL 34982 (772) 462-2172 CERTIFICATE OF TERMITE TREATAEfiT CONSTRUCTION SOIL TREATMENT PERMIT # JOB ADDRESS_ V- 2 9 Y u ,t,_ CAP a Sr+ B PEST CONTROL CONTRA PEST CONTROL LICENSE #� S(2 We, the undersigned, hereby certify that we have pretreated the above -described construction for subterranean termites in accordance with the standards of the National P t Control Association. Square feet of area treated: l 3 .l Chemicals used: f D V U i p� Percentage of solution: C Date of treatment: ❑ Footing ❑. 1st Treatment ❑ Re -treat ❑ Slab ❑ 1st Treatment ❑ Re -treat ❑ Driveway ❑ 1st Treatment ❑ Re -treat ❑ Pools ❑ - 1 st Treatment ❑ Re -treat ❑ Other . Total gallons used: . Time of Treatment: FBC104.2.6 Certificate of Protective Treatment for prevention of termites. A weather resistantiobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files. The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used, percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box covei listing all the treatments and dates of applications. ❑ 1st Treatment ❑ Re -treat ❑ Perimeter for Final Inspection NOTE: Signature of exterminator There must be a completed form for each required treatment or re -treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will Revised 6/13/02 dmr fail and a re -inspection fee charged. - E&T Dlr1:KELBERGER ENGINE+ niNG &TESTING, INC. SOIL DENSITY-.. TEST REPORT Project Name: Morningside Report Date: 06-19-07 St. Lucie County, Florida RECEIVED Lot No.: 902 Client Name: Centex Homes . Permit No.: SLC-0704-0444 3301 Quantum Boulevard, Oloor JUN 19 2007 Project No.: 06-10-2402 Boynton Beach, FL 33426 V17i Date Tested:. 06-19-07 Public works Technician Initials: AMR Attn: Mr. David Donvito St. Lucie County, Ft_ Sheet No.: 1 of 1 Test No. Probe Depth in Laborato Proctor Field Tests'.. ,. Maximum Dry Density c MoistureResistance' OptimumF112LO_Y!2�_ %(ts Cone Moisture % Minimum Required Compaction (% Percent Maximum DensityResult Test 1 12 120.0 10.0 - - - 8.2 95.0 100 Pass 2 12 120.0 10.0 119.8 - - - 8.8 95.0 99.8 Pass 3 12 120.0 10.0 120.5 - - - 8.5 95.0 100 Pass 4 12 120.0 10.0 120.1 - - - 8.3 95.0 100 Pass Type of Field Density Test: () ASTM D 1556 (X) ASTM D 2922 O ASTM D 2937 Minimum Required Compaction Based on: (X) AASHTO T-180 (ASTM'D 1557) () AASHTO T-99 (ASTM D 698) 'Cmmnactinn nerrent estimated from cone nenetrnmeter reading ohtained with a Brainard-Kilman Model S-214 hand-held cone nenetrometer. <Test No Soil <, 13 Elevation; . Test Location Lot 902,.0334.Treasure CoastlDrrye 1 2 0-12 Lot 902 at approximate center of house (slab subgrade) 2 2 0-12 Lot 902 at approximate center of garage (slab subgrade) 3 10 0-12 Lot 902 at east side of house (footing subgrade) 4 10 0-12 Lot 902 at west side of house (footing subgrade) Elevation Referenced to: () NGVD 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Footine Subgrade Note: The original of this report was signed and seal () MSL (X) Other t ests t-1: incites oeiow top or siao suograae Tests 3-4: Inches below top of footing subgrade cc: Centex Homes, David Donvito... (1) Centex Homes, Eric Otto (site trailer) ... (2) St. Lucie County, Building Inspections ... (1) Craig E. Dunkelberger, P FL,,Registration No. 499: by a registered engineer in accordance with Rule 61G15-18.011 of the n&s Ci This report is submitted as the confidential property of our client and authorization for publication of statements„conclu r eRtr2tts s this report is reserved pending our written approval. The above -referenced testing was performed at the locations:and depth.in2erval described the associated report date. No other warranties with regard to subsurface exploration, recommendations or design are expiessed by this firm. on a. JUN, 22, 2007 2;39PM E I IC CONNECTION 36%*i W� Fcb- Ie 2"`NO, 5903n P. 7/15 FRdr1 . �1/06/?.i3a7 07:69 77�46' 5t, Liocle County $ttlldln� doZonlingDr-partmellt Z3D0 vlrghda Avinite Fort rleree, IrL 3&"2 777.-463.2166 Fax 772.46;2-6443 Ftevest for 30-Vay Tem Crary I?Owtr RticB-%e oto� (7 Fet�>r111 t 1�osRtAor: S. Lc, �_. 0 D>tla: ]PxWcrty Add>ra.d1 a 3-iLk rG S TK16 UNDER19MNEO >HIEIMi1IY RLr'QVEST RNLEA Sr or, ELF-MUCAr. POWOR TO THE ,,TrMit A ;FERIOV NOT TO MCLISD THIRTY (30) DAYS, 3' ABOVE LISCRIRRDP15Y��TI B AND RQU11' NT IN MW RA ION FOR MNAIL+�R THE MRPOSE OF T.�BTING INSPECTION, I CONSIDIMkTION FOLLOWS;rPAL OF TM REQUEST VM 148-KEDY ACKNOWLEDGE AND AGREN Thli temporrry power ro195041, "yQue"A d for tht Shove 1016d perpoie anlyr and *Ire t•1N 61 no ►eaupanoy or attY ", , othrr than VIM vOr�ryllled by cus"rgeNolt dalrilso WS two fo.lvd, 4. Ad wlimas by our 91gr, ancrbr, MQ hrrwW'Area •b abldr, by all lerna dnd condlklonl or tb19 @$r*Qmnt, IF0141119Bxildlna D"AR10n Polley, ghleh If fRourpokeNd herbal by rdfuence. 3. AU eon$It 0Jw Ovid "WIr•gneglWa m 1M almWlt4 4oqumcm emit!" •9teQulramaata OF 30 Da311►o"" tbrTejWl hXYt bOoti fulll!!ad sR►d IIN pP•rnl,o Lx nerdy tot eomptinskc Iti,pemton, A, All r■gatats for on •x4ltl41no b,yond 90 diyO mn�ct At p-radc Ill Mltting to the DrdldloQ 0R1clal ,tA ft there U ba, ee been apprOYcd all bin 30 4 )%, dA Ieo of Or4,00 wW Is@ Isq fired to lltl the Stop Work Order Issued 1Work Ordtrf the ?JaRl nlper liaa ��► HtREBy )tULEASI AND AGktI9 TO HOLD HARMLKSS, ST.1,Uf; M CGUNTY, AND THEIR Eri1ELOYE$S FROM ALL LIADMITIFS AND CLAIMS OF ANY TYPE OF i�ATURE W111CfI MAY ARM NOW OR IN THE FUTUU OUT OF VUS TRANS&CTION, INCLC.MNG ANY J)AMAGX WHICH MAY DR INCURREJ) DUE To THINDISCONNECTION OF ELECTRICAL pOVMR N TRH RV?,NT OV V ODAT ON OP TRIS AaREZ RN - ��N 2 2 2007 public Worts St. Lucie county, �l- - ,JUN. 22. 2007 2:39PM ELF,_C,TjIC CONNECTION NO. 5903 P. 6/15 FROM . ELECTR I CCONNECT I ON FAX NO., :1772070525 Mr. 10 2007 12: 08PM P2 ST. LU;CIE Ci 'BUILDYNG & S1. Luc1c Country Contractor CrrtillcatiARN State of Florida Cell' cchtio_n Nom�lr tvappl' "(r 4y 1 e (h 1J1Q (COY (Q)mp►any NatneAndivid4lal Name) (Type ueTr ade) f-or the project located at -q 3 4 . i (Probe It is understood that, iftriere i$ any above mentioned project, I will imi of St, Luck County by perso�ally f No. 004-00) tusiness Naive: Address: city/state/Zip: i?11UAc: OFMCE USE Y' VTY PUBLIC WORKS iNING DEPARTMENT 'ING .P.HRMIT ,CT OR AGUEM ENT have agreed to be the actor for Aeylv?-X l�(XY1Q (.Rtinmaly Contractor) W-6ureCo *i qt Address or Prororty Tax ID 0) go of status regarding our-pnrtioipation with the ►tely advise the'Building and Zoning Department a Change of Contractor notice. (Form; SI.CCuv of the Individual ahown on the Contractorls Llomse) P UNT NAME y DAT>: iU C�4 G 0-YL email: SUN 2 2 TO Pplic Works u St. Lucie County? FL Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucieco.gov/ce Date: 31 May 2007 Job Address: 9334 TREASURE COAST ST Received By: goycochb Paid With: CK Paid By: CENTEX HOMES Building Receipt Sign: Receipt #: 0000054578 'ermit Number: SLC- 0704-0444 Amount: $8,170.84 �redit Card Number: Check Number: 165953 St. Lucie County Building & Zoning 2300 Virginia Ave Fort Pierce FL 34982 BUILDING PERMIT SUB -CONTRACTOR SUMMARY CENTEX HOMES will be using the following sub -contractors for the (Company/Individual Name) p/� �+ e n C project located at q�� I lreOSLL((?, ��� ��� (Street address or Property Tax 1D #) It is understood that if there is any change of status regarding the participation of any of the sub -contractors listed below, I will immediately advise'the Building and Zoning Department of St. Lucie County. Trade Name of Company/Contractor St. Lucie County/ State of Florida License Number Electrical / 0\ ELECTRIC CONNECTION 21055 Plumbing RIDGEWAY PLUMBING, INC. 21117 HVAC/ Mechanical PREFERRED A/C & MEACBANICAL, INC. 18980 Roofing WATERPROOFING SYSTEMS 24059 Gas OFFIC'F. I TRF. ONLY: PERMIT ISSUE DATE: NUMBER: ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: 21055 State of Florida Certification Number (If applicable): EC0002938 ELECTRIC CONNECTION have agreed to be the (Company Name/Individual Name) ELECTRIC sub -contractor for CENTEX HOMES (Type ofTrade) (Primary Contractor) for the project located at 933l I reasy m Coz+ S+ (Project Street Address or Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS UALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAjG GNATURES ARE REQUIRED SIGNATURE Business Name: Address: City/State/Zip: Phone: RANDY SJAARJEMA PRINT NAME ELECTRIC CONNECTION 1100 BARNETT DRIVE, SUITE 4 LAKE WORTH, FL 33461 561-586-6499 email: OFFICE USE ONLY: PERMIT # ISSUE DATE l a-10 T DATE AnI ST. LUCIE COUNTY PUBLIC WORKS 'TL BUILDING & ZONING DEPARTMENT r BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: 21117 State of Florida Certification Number (If applicable): CFC019077 RIDGEWAY PLUMBING, INC / GARY KOZAN (Company Name/Individual Name) have agreed to be the PLUMBING sub -contractor for CENTEX HOMES (Type of Trade) (Primary Contractor) for the project located at q9nt MQ.S(Ire- QL S (Project�et Addressor Property Tax 1D #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIGN URES ARE REQUIRED GARY SIGNATUIV PRINT NA KOZAN ME Business Name: RIDGEWAY PLUMBING Address: 640 E INDUSTRIAL AVENUE City/State/Zip: BOYNTON BEACH, FL 33426 Phone: 561-732-3176 email: OFFICE USE ONLY: PERMIT # ISSUE DATE 4"a-0' C)l DATE ST_ LUCM COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT f� RUILDING PERMIT SUBCONTRACTOR AGREEMENT SL Lucie County Contractor Certification Number_ State of Florida CertiticationNumber (ifapplicabla). P�e [c uw<< A ' C t 1 A c c_' - A 0 C - have agreed to be the (Company Namefindividua)Name) sub -contractor for (Type of Trade) (Primary Contractor) for 1be project located at q 9 0� Tr sure, C-0 aS+ (Project Street Address or Property Tax ID il) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St_ Lucie County by personally filing a Change of Contractor notice (Form_ SLCCDV No_ 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIGNATURES ARE REQUIRED 1 1( 114 ��4zfb ATURE rNT NAME Business Name_ Address: City/StaldZip: Phone: OFFICE USE ONLY: q aro DATE M ST. LUCIE COUNTY PUBLIC WORKS I BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: Ag059 State of Florida Certification Number(tfappficable): CCCO56359 WATERPROOFING SYSTEMS IBERNABE I PENA have agreed to be the (Company Name/Individual Namej ROOFING sub -contractor for CENTEX HOMES (Type of Trade) (Primary Contractor) for the project located -at 93I rea-sa re/ Coq4 (Project Street Address or Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORI NAL S T -SA E REQUIRED BERNABE I PENA SIGNATURE PRINT NAME Business Name: Address: City/State/Zip: Phone: WATERPROOFING SYSTEMS 8356 SW 8TH STREET MIAMI, FL 33144 786-388-0888 email: OFFICE USE ONLY: -0�, DATE ST. LUCIE COUNTY BUILDING & ZONING 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 772-462-1553 FILLED IAI,NDS AFFIDAVIT am.the owner of the following described property: (Tax ID/Legal description/Address) 0 go V, 6 j7z Z7z- for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number 03a5 8, I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected- I further acknowledge that in granting this permit for the development of this property, St. Lucie County is neither obliged nor liable to provide for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. Property Owner Name Property Owner Signature Date STATE OF FLORIDA. COUNTY OF PALM "BE AQA ACKNOWLEDGED BEFORE ME THIS �_ DAY OF r J � 20 4D7 BYO Y AN1T) NI M CAMS WHO 1S PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED AS IDENTIFICATION. ' dN Wboy%a I j SIGNA OF NOTARY TYPE OR PRIN'1-rVANjm L NOTARY PUBLIC-S i"d'E OF FLORIDA -ppyS"abs Imp McDonald NOTARY PUBLIC TITLE �OMMISStON NUMB Commission #DD452656 8nadad ` h uu Adande 8 ndi19, g C� OI�c Property Appraiser - St.Luci °' `,)unty, FL Page 1 of 1 PROPERTY RECORD CARD Centex Homes Record: 1 of 1 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification ��CIE Site Address: Palm Breezes Dr ParceilD: 2310-500-0158-000-5 Sec/Town/Range: 10:35S:39E Map ID: 23/10N Account #: Land Use: 166361 Vac Res Zoning: City/Cnty: ST. LUCIE COUNTY Ownership and Mailing Owner: Centex Homes Address: 8198 Jog Rd Ste 200 Boynton Beach FL 33437 Sales Information Date Price Code Deed 8/1/2005 13000000 02 WD 5/20/2004 2910000 02 WD Na Sketch Legal Description PALM BREEZES CLUB (PB 49-32) BLK 9 LOT 2 (OR 2324-2712) Assessment Final Total Land and Building Book/Page 2006 Val: 15200 Land Value: 15200 Acres: 0.09 2324 / 2712 Assessed: 15200 Building Value: 0 1973 / 1499 Ag.Credit: 0 Finished Area: 0 SgFt Exempt: 0 Taxable: 15200 TotalTax: 304.31 BUILDING INFORMATION ,G � t IrrY �c�5f a`j to i 1� b lc Exterior Features View: - RoofCover: - RoofStruct: - ExtType: - YearBlt: Frame: - Grade: - EftYrBlt: PrimeWall: - StoryHght: - No.Units: SecWall: - Interior Features BedRooms: 0 Electric: - PrmintWall: - FullBath: 0 HeatType: - AvgHUFI: 1/2Bath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth 1 0000-Vac Res 535 -Front Ft 50 110 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. [ 2v httn-//www_nacic_nr¢/nrc acn9nrr1id=211 wnni sRnnn5 d/1 R/'?007 Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 24 April 2007 Job Address: 9334 TREASURE COAST ST Received By: spellsv Paid With: CK Paid By: CENTEX HOMES Receipt#: 0000053417 -ermit Number: SLC- 0704-0444 Amount: $275.00 redit Card Number: Check Number: 164567 Sign: St. Lucie County Building and Zoning Department 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-1553 Design Certification for Wind Load Compliance This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. Project Naine MORNINGSIDE Office Use Only Street Address Permit Number 1324-1 rea wnf CpS Occupancy Type LOT BIK Construction Type Certification Statement: 1 certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. 1 also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the a propriate box.) 1. Florida Building Code 2004 Edition ASCE 7-98_ 2. Building Design is (check one) Enclosed Partially Enclosed Open Building 3. Building Height: 24 ► _411 4. Wind Speed Used in Building Design: 1-1() 3 second gust 5. Wind Exposure Classification (refer to exposure tables in Building Code identified in Line #1): B 6. Average Wind Velocity Pressure on Exterior Faces of Structure 25.74 PSF _ 7. Peak Wind Velocity Pressure on Exterior Faces of Structure NSA PSF 8. Importance/Use Factor (obtain from Building Code): 1.0 1 9. Loads: Floor 55 PSF Roof/dead 25 PSF Roof/live 30 PSF 10. Were Shear Walls Considered for Structure (check one): Yes ✓ No (if No, attach explanation) 11. Is a Continuous Load Path Provided (check one): Yes ✓ No (if No, attach explanation) 12. Are Component and Cladding Detail Provided (check one): Yes I/ No (if No, attach explanation) 13. Minimum Soil Bearing Pressure: 2,500 PSF r, As witnessed by my seal, I hereby certify that the information included with this certification is true and correct, to the best of my knowledge and belief. Name: SCOTT R. BRENNAN Design Firm` BRENNAN ENGINEERING, INC. Certification #: 51311 [Seal Here Date: �4 —6)-o SLCCDV Form # 020-00 rev 15/605 `m 1 FORM 60OA-2004R EnergyGauge® 4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A 0 Project Name: CENOORNINGSIDE 1577 3-05-07 Builder: CENTEX HOMES Address: Lot- � Sub: MOORNINGSIDE, Plat: Permitting Office: City, state: ST LUCIE COUNTY, FL Permit Number: Owner: CUSTOM Jurisdiction Number: Climate Zone: Central L New construction or existing New _ 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 2 _ 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft) 1577 ft2 7. Glass typel and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default)168.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 168.0 ft' _ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 131.0(p) ft _ b. N/A _ c. N/A 9. Wall types _ a. Concrete, Int Insul, Exterior R=4.1, 1969.0 ft- b. Frame, Steel, Adjacent R=11.0, 81.0 ft- c. Concrete, Int Insul, Adjacent R=4.1, 169.0 ft2 _ d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic _ R=19.0, 812.0 ft2 b. N/A _ c. N/A _ 11. Ducts - a. Sup: Unc. Ret: Con. AH: Interior Sup. R=6.0, 175.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 36.4 kBtu/hr _ SEER:13.00 _ Cap: 15.5 kBtu/hr _ HSPF: 7.70 b. N/A c. N/A FILE Uopy_ 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons _ EF:092 _ b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits PT, _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.11 Total as -built points: 18419 PASS Total base points: 18905 I hereby certify that the lans and specific ' s cover y this calculation are in compliance with a Florida rgy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Ener OWNER/AGEN DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGaugeO (Version: FLRCPB v4.5.2) y�yo.THE ST,g?AOAve rnrr - ��°•` °o C7 rpcoD W-E FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .16 1577.0 24.35 6912.0 1.Single, Clear W 1.6 17.0 30.0 57.68 1.00 1724.0 2.Single, Clear W 13.0 8.0 40.0 57.68 0.45 1038.0 3.Single, Clear S 1.0 17.0 15.0 48,22 0.99 719.0 4.Single, Clear W 1.0 6.0 30.0 57.68 0.97 1678.0 5.Single, Clear S 1.0 6.0 15.0 48.22 0.95 685.0 6.Single, Clear E 1.0 6.0 30.0 63.97 0.97 1862.0 7.Single, Clear E 1.0 5.0 8.0 63.97 0.95 486.0 As -Built Total: 168.0 8192.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 250.0 0.70 175.0 1. Concrete, Int Insul, Exterior 4.1 1969.0 1.18 2323.4 Exterior 1969.0 1.90 3741.1 2. Frame, Steel, Adjacent 11.0 81.0 1.00 81.0 3. Concrete, Int Insul, Adjacent 4.1 169.0 0.65 109.0 Base Total: 2219.0 3916.1 As -Built Total: 2219.0 2513.4 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 18.0 1.60 28.8 1.Exterior Insulated 24.0 4.80 115.2 Exterior 24.0 4.80 115.2 2-Adjacent Insulated 18.0 1.60 28.8 Base Total: 42.0 1".0 As -Built Total: 42.0 144.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 812.0 2.13 1729.6 1. Under Attic 19.0 812.0 2.82 X 1.00 2289.8 6 Base Total: 812.0 1729.6 As -Built Total: 812.0 2289.8 FLOOR TYPES , Area X BSPM = Points Type R-Value Area X SPM = Points Slab 131.0(p) -31.8 4165.8 1. Slab -On -Grade Edge Insulation 0.0 131.0(p -31.90 -4178.9 Raised 0.0 0.00 0.0 Base Total: -4165.8 As -Built Total: 131.0 -4178.9 INFILTRATION Area X BSPM = Points Area X SPM = Points 1577.0 14.31 22566.9 1577.0 14.31 22566.9 EnergyGauge® DCA Form 60OA-2004R EnergyGaugeO/FlaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details . _ ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT Summer Base Points: 7,77 Summer As -Built Points: 31527.2 Total Summer X System = Cooling Total X Cap X Duct X. System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 36400btuh ,SEER/EFF(13.0) Ducts: Unc(S),Con(R),lnt(AH),R6.0(INS) 31527 1.00 (1.08 x 1.150 x 0.90) 0.260 0.950 8696.5 31102.7 0.3250 10108.4 31527.2 1.00 1.117 0.260 0.950 8696.5 EnergyGaugeTM' DCA Form 600A-2004R EnergyGauge®/FIaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1577.0 9.11 2586.0 1.Single, Clear W 1.0 17.0 30.0 13.25 1.00 397.0 2.Single, Clear W 13.0 8.0 40.0 13.25 1.10 585.0 3.Single, Clear S 1.0 17.0 15.0 9.90 1.00 148.0 4.Single, Clear W 1.0 6.0 30.0 13.25 1.00' 398.0 5.Single, Clear S 1.0 6.0 15.0 9.90 1.01 149.0 6.Single, Clear E 1.0 6.0 30.0 12.37 1.01 374.0 7.Single, Clear E 1.0 5.0 8.0 12.37 1.01 100.0 As -Built Total: 168.0 2151.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 250.0 1.80 450.0 1. Concrete, Int Insul, Exterior 4.1 1969.0 3.31 6507.5 Exterior 1969.0 2.00 3938.0 2. Frame, Steel, Adjacent 11.0 81.0 2.60 210.6 3. Concrete, Int Insul, Adjacent 4.1 169.0 2.08 351.5 Base Total: 2219.0 4388.0 As -Built Total: 2219.0 7069.7 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 18.0 4.00 72.0 1.Exterior Insulated 24.0 5.10 122.4 Exterior 24.0 5.10 122.4 2.Adjacent Insulated 18.0 4.00 72.0 Base Total: 42.0 194.4 As -Built Total: 42.0 194.4 ..CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 812.0 0.64 519.7 1. Under Attic 19.0 812.0 0.87 X 1.00 706.4 t -Base Total: 812.0 519.7 As -Built Total: 812.0 706.4 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 131.0(p) -1.9 -248.9 1. Slab -On -Grade Edge Insulation 0.0 131.0(p 2.50 327.5 Raised 0.0 0.00 0.0 Base Total: -248.9 As -Built Total: 131.0 327.5 INFILTRATION Area X BWPM = Points Area X WPM = Points 1577.0 -0.28 -441.6 1577.0 -0.28 -441.6 EnergyGauge® DCA Form 60OA-2004R EnergyGauge@/FlaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT Winter Base Points: 6997.6 Winter As -Built Points: 10007.4 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points , Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 15500 btuh ,EFF(7.7) Ducts:Unc(S),Con(R),Int(AH),R6.0 10007.4 1.000 1 (1.068 x 1.160 x 0.92)0.443 0.950 4803.0 6997.6 0.5540 3876.7 10007.4 1.00 1.140 0.443 0.950 4803.0 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge@/FlaRES'2004R FLRCPB v4.5.2 } FORM 60OA-2004R EnergyGauge® 4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT INATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2460.00 4920.0 40.0 0.92 2 1.00 2460.00 1.00 4920.0 As -Built Total: 4920.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling + Heating + Hot Water = Total Points Points Points Points 10108 3877 4920 18905 8697 4803 4920 18419 v PASS WE EnergyGauge'rm DCA Form 60OA-2004R EnergyGauge®/FlaRES'200411 FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details . _ ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial'pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. Ll EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge@)/FlaRES'2004R FLRCPB v4.5.2 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 86.5 The higher the score, the more efficient the home. CUSTOM, Lot%�,, Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, 1. New construction or existing New 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 4. Number of Bedrooms 2 5. Is this a worst case? Yes 6. Conditioned floor area (ft) 1577 ftz 7. Glass type and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 168.0 ft' b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 168.0 ft2 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 131.0(p) ft b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior R=4.1, 1969.0 ft' b. Frame, Steel, Adjacent R=11.0, 81.0 ft' c. Concrete, Int lnsul, Adjacent R=4.1, 169.0 ft2 d. N/A e. N/A 10. Ceiling types a. Under Attic R=19.0, 812.0 ft" b. N/A c. N/A 11. Ducts ' a. Sup: Unc. Ret: Con. AH: Interior Sup. R=6.0, 175.0 ft b. N/A 12. Cooling systems a. Central Unit Cap: 36.4 kBtu/hr SEER: 13.00 b. N/A c. N/A 13. Heating systems a. Electric Heat Pump Cap: 15.5 kBtu/hr HSPF:7.70 _ b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons _ EF: 0.92 b. N/A _ c. Conservation credits _ (HR-Heat recovery, Solar DHP-Dedicated beat pump) _ 15. HVAC credits PT, _ (CF-Ceiling fan, CV -Cross ventilation, _ HIP -Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building �IiB sTq Construction through the above energy saving features which will be installed (or exceeded) VO e _ TAo in this home before final inspection. Otherwise, a new EPL Display Card will be completed.,,, based on installed iant features. Builder Signa Date: 0 D y Address of New Home: 60's i /FL Zi F... �� e. , C C R3N_Re� uv 4ty p: oDW *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPAIDOE EnergyStarT"'designation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list of certifted Raters. For information about Florida's Energy Efficiency' Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. I Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on ages 2&4. EnergyGauge® (Version: FLRCPB v4.5.2) Load Short Form Date: r ell/l'1 Ji1t.S0'rt"' Date: thedght°6a#e Entire House By: PREFERRED AIR CONDITIONING & MECHANICAL, Inc. • • e • For: MOORNINGSIDE, CENTEX HOMES 1577, ST LUCIE COUNTY, FL Q- • •rmitio Htg Clg Infiltration Outside db (OF) 42 90 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TD (OF) 28 15 Fireplaces 0 Daily range - L Inside humidity (%) - 50 Moisture difference (gr/lb) - 61 HEATING EQUIPMENT Make Lennox Trade 13HPD Series Model 13HPD-036-230* Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 7.7 HSPF 33800 Btuh @ 47°F 26 OF 1173 cfm 0.041 cfm/Btuh 0.00 in H2O COOLING EQUIPMENT Make Lennox Trade 13HPD Series Cond 13HPD-036-230* Coil CB26UH-036* Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13 SEER 25480 Btuh 10920 Btuh 36400 Btuh 1173 cfm 0.045 cfm/Btuh 0.00 in H2O 0.81 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) CIg AVF (cfm) FOYER 84 3273 1731 136 79 GREAT ROOM 416 7804 5238 323 238 POWDER 25 0 0 0 0 DINING 117 3318 2353 137 107 KITCHEN 200 3545 3327 147 151 BATH 2 48 1475 1509 61 69 WIC 2 30 51 142 2 6 BEDROOM 2 156 1657 2692 69 122 MASTER BATH 65 1653 1761 68 80 MASTER BEDROOM 174 2286 3267 95 149 WIC 1 75 376 543. 16 25 1/lCT 407 700C 7/lnA 44n 4A7 \1 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnghtsoft RightSuiite Residential 6.0.95 RSR43667 2007-Mar-08 09:16:42 AC01, CADoc umerds and Settings\EngDepLPREFERREDACW y Documents\right t10ENTEX MOORNINGSIDE115773-5-07. Page 1 Entire House d 1577 28323 25786 1173 1173 Other equip loads 1092 585 Equip. @ 0.95 RSM 25053 Latent cooling 6320 -r OTALS 1577 29415 31373 1173 1173 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ,� wnghtsoft RightSuite Resideritial 6.0.95 RSR43667 2007-Mar-08 09:16:42 ACCA CADocuments and Settings\EngDept.PREFERREDAC\My DocumenMightjACENTEX MOORNINGSIDE\1577-3-5-07. Page 2 -fil- wrightsoft- Right-J Worksheet Job: Entire House Date: PREFERRED AIR CONDITIONING & MECHANICAL, Inc. 1 Room name Entire House FOYER 2 Exposed wall 245.0 ft 27.0 ft 3 Ceiling height 9.0 ft d 9.0 ft heat/cool 4 5 Room dimensions Room area 1577.0 ft2 12.0 x 7.0 ft 84.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft) Load number (13tuh/ft2 °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PiS Heat Cool Gross N/P/S Heat Cool 6 51A 0.116 nw 3.25 2.78 2205 1969 6395 5482 243 219 711 610 1A-clom 1.270 se 35.56 29.00 12 4 427 310 0 0 0 0 1A-c1om 1.270 se 35.56 29.00 30 5 1067 813 0 0 0 0 1A-clom 1.270 sw 35.56 29.00 15 0 533 435 0 0 0 0 11 1Aclom 1.270 sw 35.56 29.00 30 5 1067 813 0 0 0 0 1A-c1omd 1.270 nw 35.56 28.39 40 0 1422 1136 0 0 0 0 IA-c1om 1.270 nw 35.56 28.39 15 0 533 426 0 0 0 0 1A-clom 1.270 nw 35.56 28.39 30 0 1067 852 0 0 0 0 IINO 0.350 nw 9.80 10.15 64 64 627 650 24 24 235 244 P 1213-0bm 0.122 3.42 1.07 81 81 277 87 81 81 277 87 L51 B 0.116 3.25 1.64 189 169 549 276 0 0 0 0 11NO 0.350 n 9.80 10.15 20 20 196 203 0 0 0 0 C 16A-19ad 0.049 1.37 3.55 812 812 1114 2885 77 77 106 274 F 22A-vph 1.358 38.02 O.00 1577 131 4981 0 84 27 1027 0 F 20P-0t 0.521 14.59 6.51 0 0 0 i 0 0 0 0 0 61 c) AED excursion 914 -79 Envelope loss/gain 20256 15280 2356 1135 12 a) Infiltration 2766 780 305 86 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances @ 1200 1 1200 0 0 Subtotal (lines 6 to 13) 23022 18180 2660 1221 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23022 18180 2660 1221 15 Duct loads 23% 42%1 5301 7607 23% 42% 613 511 Total room load - 28323 25786 3273 1731 Air required (cfm) 1173 1173 136 79 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. t wW'14C Oi t Rlght Suite Residential 6.0.95 RSR43667 2007-Mar-08 09:16.42 ACC:\Documents and Settings\EngDept.PREFERREDAC\My Documents\right j\CENTE)C MOORNINGSIDE\1577-3-5-07. Page 1 wrights®ftRight-J Worksheet Job: Onlight cham Entire House Date: By: PREFERRED AIR CONDITIONING & MECHANICAL, Inc. 1 Room name GREAT ROOM POWDER 2 Exposed wall 52.0 ft 0.0 ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heattcool 4 Room dimensions 26.0 x 16.0 ft 5.0 x 5.0 ft 5 Room area 416.0 ft2 25.0 ft2 Ty Construction U-value Or HTM Area (ft) Load Area (ft2) Load number (Btuh/ft2-*F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A 0.116 nw 3.25 2.78 468 393 1276 1094 0 0 0 0 IA-clom 1.270 se 35.56 29.00 0 0 0 0 0 0 0 0 1A-c1om 1.270 se 35.56 29.00 0 0 0 0 0 0 0 0 IA-clom 1.270 sw 35.56 29.00 15 0 533 435 0 0 0 0 11 IA-clom 1.270 sw 35.56 29.00 0 0 0 0 0 0 0 0 IA-clomd 1.270 nw 35.56 28.39 40 0 1422 1136 0 0 0 0 1A-clom 1.270 rnu 35.56 28.39 0 0 0 0 0 0 0 0 IA-clom 1.270 nw 35.56 28.39 0 0 0 0 0 0 0 0 11N0 0.350 nw 9.80 10.15 20 20 196 203 0 0 0 0 P 1213-0bm 0.122 - 3.42 1.07 0 0 0 0 0 0 0 0 R 51 B 0.116 - 3.25 1.64 108 108 351 177 0 0 0 0 T-D 11 NO 0.350 n 9.80 10.15 0 0 0 0 0 0 0 0 C 16A-19ad 0.049 - 1.37 3.55 0 0 0 0 0 0 0 0 F 22A-vph 1.358 - 38.02 0.00 416 52 1977 0 25 0 0 0 F 20P-0t 0.521 - 14.69 6.51 0 0 0 0 0 0 0 0 6 c) AED excursion 483 0 Envelope losstgain 5756 3527 0 0 12 a) Infiltration 587 166 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances @ 1200 0 0 0 0 0 0 0 0 Subtotal (lines 6 to 13) 6343 3693 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6343 3693 0 0 15 Duct loads 23% 42% 1461 1545 23% 42% 0 0 Total room load 7804 52381 0 0 Air required (cfm) 323 238 -7 0 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr rightsOfC RightSuite Residential 6.0.95 RSR43667 2007-Mar-08 09:16:42 ACC l- C:\Documents and Settings\EngDept.PREFERREDAC\My Documents\right jICENTEX MOORNINGSIDE\157735-07. Page 2 + - wrilghtsoft- Right-J Worksheet Job: Entire House Date: PREFERRED AIR CONDITIONING & By: MECHANICAL, Inc. 1 Room name DINING KITCHEN 2 Exposed wall 22.0 ft 30.0 ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heattcool 4 Room dimensions 13.0 x 9.0 ft 16.0 x 12.5 It 5 Room area 117.0 ft= 200.0 ft' Ty Construction U-value Or HTM Area (W) Load Area (W) Load number (Btuh/ft- °F) (Btu'n/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A 0.116 nw 3.25 2.78 198 168 546 468 270 250 812 696 IA-c1om 1.270 se 35.56 29.00 0 0 0 0 0 0 0 0 IA-clom 1.270 se 35.56 29.00 0 0 0 0 0 0 0 0 1A-c1om 1.270 sw 35.56 29.00 0 0 0 0 0 0 0 0 11 1A-clom 1.270 sw 35.56 29.00 0 0 0 0 0 0 0 0 1A-c1omd 1.270 nw 35.66 28.39 0 0 0 0 0 0 0 0 1A-clom 1.270 nw 35.56 28.39 0 0 0 0 0 0 0 0 IA-c1om 1.270 nw 35.56 28.39 30 0 1067 852 0 0 0 0 11 NO 0.350 nw 9.80 10.15 0 0 0 0 20 20 196 203 P 1213-0bm 0.122 3.42 1.07 0 0 0 0 0 0 0 0 PI ' D 51 B 11 NO 0.116 0.350 n 3.25 9.80 1.64 10.15 0 0 0 0 0 0 0 0 81 20 61 20 198 196 100 203 C 16A-19ad 0.049 1.37 3.55 0 0 0 0 0 0 0 0 F 22A-vph 1.3%8 - 38.02 0.00 117 22 837 0 200 30 1141 0 F 2OP-M 0.521 14.59 6.51 0 0 0 0 0 0 0 0 61 c) AED excursion 1269 -152 Envelope loss/gain 2449 1589 2543 1050 12 a) Infiltration 248 70 339 95 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 1 1200 Subtotal (lines 6 to 13) 2697 1659 2882 2345 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2697 1659 2882 2345 15 Duct loads 23% 42% 621 694 23% 42% 664 981 Total room load 3318 2353 3545 3327 Air required (cf n) 11371 107 147 151 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrrag ht50i t RightSuite Residerdial 6.0.95 RSR43667 2007-Mar-08 09:16:42 ACGP, CADocuments and Settings\EngDept.PREFERREDAC\My Documents\rigtd j10ENTEX MOORNINGSIDE\1577-3b07. Page 3 wrllghtsoft7 Right-J Wor ksheet Job: lb-10`d=l- Entire House By: PREFERRED AIR CONDITIONING & MECHANICAL, Inc. 1 Room name DINING KITCHEN 2 Exposed wall 22.0 ft 30.0 ft 3 Ceiling height 9.0 ft - heat/cool 9.0 ft heat1cool 4 Room dimensions 13.0 x 9.0 ft 16.0 x 12.5 ft 5 Room area 117.0 ft2 200.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuh/ft'L°F) (Btuh/ft.) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 51A 0.116 nw 3.25 2.78 198 168 546 468 2701 250 812 696 1A-clom 1.270 se 35.56 29.00 0 0 0 0 0 0 0 0 1Aclom 1.270 se 35.56 29.00 0 0 0 0 0 0 0 0 IA-c1om 1.270 sw 35.56 29.00 0 0 0 0 0 0 0 0 11 IA-clom 1.270 sw 35.56 29.00 0 0 0 0 0 0 0 0 1A-clomd 1A-c1om 1.270 1.270 nw nw 35.56 35.56 28.39 28.39 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IA-c1om 1.270 nw 35.56 28.39 30 0 1067 852 0 0 0 0 11 NO 0.350 nw 9.80 10.15 0 0 0 0 20 20 196 203 P 1213-0bm 0.122 - 3.42 1.07 0 0 0 0 0 0 0 0 P L-D 51 B 11NO 0.116 0.350 - n 3.25 9.80 1.64 10.15 0 0 0 0 0 0 0 0 81 20 61 20 198 196 100 203 C 16A-19ad 0.049 - 1.37 3.55 0 0 0 0 0 0 0 0 F 22A-vph 1.358 - 38.02 0.00 117 22 837 0 200 30 1141 0 F 20P-0t 0.521 - 14.59 6.51 0 0 0 0 0 0 0 0 6 c) AED excursion 269 -152 Envelope loss/gain 2449 1589 2543 1050 12 a) Infiltration 248 70 339 95 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 1 1200 Subtotal (lines 6 to 13) 2697 1659 2882 2345 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2697 1659 2882 2345 151 Duct loads 1 23% 42% 621 694 23% 42% 664 981 Total room load 3318 2353 3545 3327 Air required (cfm) 137 107 147 151 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrraghtSOTC RightSuite Residential 6.0.95 RSR43667 2007-Mar-08 09:16:42__ ACZP. C:\Documents and Settings\EngDept.PREFERREDAC\My Documentslright j\CENTEX MOORNINGSIDEA1577-3-0-07. Page 3 - wrightsoft Right-J Worksheet Job: Entire House Date: PREFERRED AIR CONDITIONING & By: MECHANICAL, Inc. 1 Room name BATH 2 WIC 2 2 Exposed wall 16-0 ft 0.0 ft 3 4 Ceiling height Room dimensions 9.0 ft heat/cool 6.0 x 8.0 ft 9.0 ft heat/cool 5.0 x 6.0 It 5 Room area 48.0 ft2 30.0 112 Ty Construction U-value Or HTWI Area (ft) Load Area (ft) Load number (Btuh/ft2--°F) (Btuhift2) or perimeter (ft) - - (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1 51A 0.116 nw 3.25 2.78 144 129 419 359 0 0 0 0 1Aclom 1.270 se 35.56 29.00 0 0 0 0 0 0 0 0 1A-C1om 1.270 se 35.56 29.00 15 3 533 406 0 0 0 0 1A-c1om 1270 sw 35.56 29-00 0 0 0 0 0 -0 0 0 11 1A-clom 1.270 sw 35.56 29.00 0 0 0 0 0 0 0 0 IA-clomd 1270 nw 35.56 28.39 0 0 0 0 0 0 0 0 IA-clom 1.270 nw 35.56 28.39 0 0 0 0 0 0 0 0 1.270 nw 35.56 28.39 0 0 0 0 0 0 0 0 LjIA-clom 11 NO 0.350 nw 9.80 10.15 0 0 0 0 0 0 0 0 P 126-0bm 0.122 - 3.42 1.07 0 0 0 0 0 0 0 0 P L-D 51B 11 NO 0-116 0.350 - n 3.25 9.80 1.64 10.15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16A-19ad 0.049 1.37 3.55 48 48 66 171 30 30 41 107 F 22A-vph 1.358 38.02 0.00 48 0 0 0 30 0 01 0 F 20P-0t 0.521 14.59 6.51 0 0 0 0 0 0 0 0 6 c) AED excursion 77 -6 Envelope loss/gain 1018 1013 41 100 12 a) Infiltration 181 51 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 1199 1064 41 100 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1199 1064 41 100 15 Duct loads 23% 42% 276 445 23% 42% 9 42 Total room load 1475 1509 51 142 Air required (cfm) 61 69 2 6 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsoTC Right -Suite Residerrtial 6.0.95 RSR43667 2007-Mar-08 09:16:42 ACC-6, C:\Documents and Settings\EngDeptPREFERREDAC\My Documentslright 1'\CENTEX MOORNINGSIDE\1577-3-5-07. Page 4 -� wrightsoft- Right-J Worksheet Job: �'"O"� Entire House Date: PREFERRED AIR CONDITIONING & By: MECHANICAL, Inc. 1 Room name BEDROOM 2 MASTER BATH 2 Exposed wall 16.0 It 19.0 It 3 Ceiling height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 13.0 x 12.0 It 5.0 x 13.0 It 5 Room area 156.0 fN 65.0 IF Ty Construction U-value Or HTM Area (ft) Load Area (W) Load number _ (Btuh/ft2-"F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 51A IA-clom 1A-c1om IA-c1om IA-c1om IA-c1omd 1A-c1om 1A-clom 11 NO 1213-0bm 0.116 1.270 1.270 1.270 1.270 1270 1.270 1.270 0.350 0.122 nw se se sw sw nw nw nw nw - 325 35.56 35.56 35.56 35.56 35.56 35.56 35.56 9.80 3.42 2.78 29.00 29.00 29.00 29.00 28.39 28.39 28.39 10.15 1.07 144 0 0 0 15 0 0 0 0 0 129 0 0 0 3 0 0 0 0 0 419 0 0 0 533 0 0 0 0 0 359 0 0 0 406 0 0 0 0 0 171 0 0 0 15 0 0 .0 0 0 156 0 0 0 3 0 0 0 0 0 507 0 0 0 533 0 0 0 0 0 434 0 0 0 406 0 0 0 0 0 - P P L--D C 51 B 11 NO 16A-19ad 0.116 0.350 0.049 - n - 3.25 9.80 1.37 1.64. 10.15 3.55 0 0 156 0 0 156 0 0 214 0 0 554 0 0 65 0 0 65 0 0 89 0 0 231 F 22A-vph 1.358 - 38.02 0.00 156 0 0 0 65 0 0 0 F 20P-M 0.521 - 14.59 6.51 0 0 0 0 0 0 0 0 61 c) AED excursion 671 1110 Envelope loss/gain 1166 1387 1129 1181 12 a) Infiltration 181 51 215 60 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 2 460 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 1347 1898 1344 1242 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1347 1898 1344 1242 15 Duct loads 23% 42% 310 794 23% 42% 309 520 Total room load 1657 2692 1653 1761 Air required (cfm) 169 122 I 68 80 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsoft RightSuite Residential 6.0.95 RSR43667 2007-Mar-08 09:16:42 /CC3" C:\Documents and Settings\EngDept.PREFERREDAC\My Doxuments\right j\CENTEX MOORNINGSIDE\1577-3-5-07. Page 5 + wrightsoftRight-J Worksheet Job: Entire House Date: PREFERRED AIR CONDITIONING & By: MECHANICAL, Inc. 1 Room name MASTER BEDROOM WIC 1 2 Exposed wall 28.0 ft 5.0 ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heat/cool 4 5 Room dimensions Room area 14.5 x 12.0 ft 174.0 ft' 5.0 x 15.0 It 75.0 ft2 Ty Construction U-value Or HTM Area (ft) Load Area (ft) Load number (Btuh/ft2-*F) (Btuhfft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)-- Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A 0.116 nw 3.25 2.78 252 237 770 660 45 45 146 125 1Aclom 1.270 se 35.56 29.00 0 0 0 0 0 0 0 0 1A-c1om 1.270 se 35.56 29.00 0 0 0 0 0 0 0 0 IA-clom 1.270 sw 35.56 29.00 0 0 0 0 0 0 0 0 11 IA-clom 1.270 sw 35.56 29.00 0 0 0 0 0 0 0 0 1A-c1omd 1.270 nw 35.56 28.39 0 0 0 0 0 0 0 0 IA-clom 1.270 nw 35.56 28.39 15 0 533 426 0 0 0 0 LjIA-clom 1.270 nw 35.56 28.39 0 0 0 0 0 0 0 0 11NO 0.350 nw 9.80 10.15 0 0 0 0 0 0 0 0 P 12B-0bm 0.122 - 3.42 1.07 0 0 0 0 0 0 0 0 P L--D 51 B 11 NO 0.116 0.350 - n 3.25 9.80 1.64 10.15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16A-19ad 0.049 - 1.37 3.55 174 174 239 618 75 75 103 266 F 22A-vph 1.358 - 38.02 0.00 174 0 0 0 75 0 0 0 F 20P-0t 0.521 - 14.59 6.51 0 0 0 0 0 0 0 0 6 c) AED excursion 50 -25 Envelope loss/gain 1542 1754 249 367 12 a) Infiltration 316 89 56 16 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 1858 2303 306 383 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1858 2303 306 383 15 Duct loads 23% 42% 428 964 23% 42% 70 160 Total room load 2286 3267 376 543 Air required (cfm) 95 149 16 25 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wring F ttt50 Ft Right -Suite Residential 6.0.95 RSR43667 2007-Mar-08 09:16:42 ACC. C:1Documents and Settings\EngDept.PREFERREDACWIy DocumentstrightllCENTEX MOORNINGSIDE11577-3-5-07. Page 6 -rF wrightsoft- Right-J Worksheet Job: Entire House Date: PREFERRED AIR CONDITIONING & By: MECHANICAL, Inc. 1 Room name LOFT 2 Exposed wall 30.0 ft 3 Ceiling height 9.0 ft heat/cool 4 5 Room dimensions Room area I 17.0 x 11.0 ft 187.0 ft2 Ty Construction U-value Or HTM Area (ft) Load Area Load number (13tuh/ft2-°F) (Btuh/ft2) or perimeter "(ft) (Btuh) or perimeter Heat 1 Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A 0.116 nw 3.25 2.78 270 243 789 677 IA-clom 1.270 se 35.56 29.00 12 4 427 310 1A-clom 1.270 se 35.56 29.00 15 3 533 406 1A-clom 1.270 sw 35.56 29.00 0 0 0 0 11 IA-c1om 1A-clomd 1.270 1.270 sw nw 35.56 35.56 29.00 28.39 0 0 0 0 0 0 0 0 IA-clom 1.270 nw 35.56 28.39 0 0 0 0 1.270 nw 35.56 28.39 0 0 0 0 Lj1A-clom 11NO 0.350 nw 9.80 10.15 0 0 0 0 P 1213-0bm 0.122 - 3.42 1.07 0 0 0 0 R 51B 0.116 - 3.25 'i.64 0 0 0 0 11 NO 0.350 n 9.80 10.15 0 0 0 0 -0 C 16A-19ad 0.049 - 1.37 3.55 187 187 257 664 F 22A-vph 1.358 - 38.02 0.00 187 0 0 0 F 20P-0t 0.521 - 14.59 6.51 0 0 0 0 6 c) AED excursion 120 Envelope loss/gain 2006 2177 12 a) Infiltration 339 95 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances @ 1200 0 0 Subtotal (lines 6 to 13) 2345 2273 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2345 2273 15 Duct loads 23% 42% 540 951 Total room load 2885 3224 Air required (cfm) 119 147 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr-�g htsoft RightSuRe Residential 6.0.95 RSR43667 2007-Mar-08 09:16:42 C:1Documents and Settings\EngDept.PREFERREDAC\My Documentslright 110ENTEX MOORNINGSIDE\1577-3-5-07. Page 7 'elayFax via part COM1 From: 863 967 0137 3/2/2007 9:05:49 AM (Page 1 of 1) Mar 02 07 10:13a Fi Foil Company 863 967 0137 p.l MASONRY WALL SYSTEM VALUES /S 7 ^7 Component R-Value Outside Air Film 0.17 Stucco 1/2" 1.00 8" Block 1.11 3/4" Furring 1.10 (24" O.C.) Fi-Foil's AA-2 Vapor Shield Hieh Perm Reflective Insulation on 3/4" furring 4.1 1/2" Gypsum Wall Board 0.45 Inside Air Film 0.68 Total R-value = 8.61 c'j Vo Lve The R-values shown are from the ASHRAE Handbook of fundamentals except for the Insulation. Fi-Foil's Insulations are tested to ASTM Standards and have SBCCI Compliance Reports are available. *Rounded to whole number 11A Z - d-z�3 SUS 7l01 7 DATE 02/01/0T PAGE 1 Unhlersal Forest Products' RE: X06-019 CENTEX HOMES Model 1577 'A' Site Information: Project Customer: CENTEX HOMES Project Name: Model 1577 W Lot/Block: 90 Z Model: 1577'A' Address: Q%3�' Ti-�Q re CoQ Subdivision:Morningside FILE CO,PY City: Ft. Pierce State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions Design Code: FBC2004/TP12002 Design Program: MiTek 20/20 6.3 Wind Code: N/A Wind Speed:140mph Design Method: User defined Roof Load:20.0-15.0-10.0-10.0 Floor Load: 40.0,10.0,0.0,5.0 1 X06-019 A01 02/01/07 26 X06-019 CJ3 02/01/07 2 X06-019 A02 02/01/07 27 X06-019 CJ3P 02/01/07 3 X06-019 A03 02/01/07 28 X06-019 CJ3PA 02/01/07 4 X06-019 A04 02/01/07 29 X06-019 CJ3U 02/01/07 5 X06-019 A05 02/01/07 30 X06-019 CJ3UA 02/01/07 6 X06-019 A06 02/01/07 31 X06-019 CJ5 02/01/07 7 X06-019 A07 02/01/07 32 X06-019 CJ5U 02/01/07 8 X06-019 A08 02/01/07 33 X06-019 EJ5 02/01/07 9 X06-019 A09 02/01/07 34 X06-019 EJ5P 02/01/07 10 X06-019 A10 02/01/07 35 X06-019 EJ5U 02/01/07 11 X06-019 A11 02/01/07 36 X06-019 ER 02/01/07 12 X06-019 B01 02/01/07 37 X06-019 ERU 02/01/07 A X06-019 B02 02/01/07 38 X06-019 FG1 02/01/07 14 X06-019 B03 02/01/07 39 X06-019 FG2 02/01/07 15 X06-019 B04 02/01/07 40 X06-019 FG3 02/01/07 16 X06-019 B05 02/01/07 41 X06-019 HJ2 02/01/07 17 X06-019 B06 02/01/07 42 X06-019 HJ5 02/01/07 18 X06-019 B07 02/01/07 43 X06-019 HJ5A 02/01/07 19 X06-019 B08 02/01/07 44 X06-019 HJ5P 02/01/07 20 X06-019 B09 02/01/07 45 X06-019 HJ5U 02/01/07 21 X06-019 C01 02/01/07 46 X06-019 HJ7 02/01/07 22 X06-019 CO2 02/01/07 47. X06-019 HRU 02/01/07 23 X06-019 CJ1 02/01/07 48. X06-019 MV2 &01/07 24 X06-019 CJ1P 02/01/07 49 X06-019 F01 02/01/07 25 X06-019 CJ1U 02/01/07 50 X06-019 F02 W11►tmvOfk/ u Wt The truss drawing(s) refrenced above have been prepared by MiTek Industries, Inc. �.�`�� - ... �%QJl�7�i, under my direct supervision based on the parameters provided by UFP- tl 'erce, FL.! •••�,�C E/�5.'•. 'truss Design Engineer's Name: Tan, Seng-Chaff My license renewal date for the state of Florida is February 28,2007. NOTE: The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular ��R building is the responsibility of the building designer, per ANSI/TPI-1 Chapter 2 /�,• Flo. 67 N9Se,g-Chai Tan, FL Lic #46765 Q •, SSA S 01^ • Z 345 Alhambra PL �� .(� •• West Palm Beach, FL 33405 '%�Sj•. O fI IQ• MiTek Industries, IrtG, �� lS►��AIA� ,G FLCert.#6634 �4 ,YY b ''NIIIJ11 11111\l\\\�\\``` FEB 0 1 20 toglfrled� �d��t�fil>Ir.T�fl�eag�ilgiv�,es�n�e�EOnforms to 61G15-31. (h�; �s�nF�rtx LR' rJ O��y''� ��elScitpllg�pfjbg c�5ed only upon parameters shown, and Is for an Individual building component. Suite #300 pphca i i o esign parame ers a o �r Yp Ytit btu ml onent is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding v fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component MiTek® Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 X O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector'plafes, r. * Plate location details available in MiTek 20/20 software or upon request. C PLATE SIZE The firstciimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO 4922, 5243, 5363, 3907 BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A U14 Indicates location where bearings (supports) occur, Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPl1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. AGeneral 'Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always, required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses, 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.l_ O U 4. Cut members to bear tightly against each other, a 5. Place plates on each face of truss at each joint and embed fully. Knots and'wane'atjoint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed-1 9% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® el DATE 02/01/O7 PAGE 2 UnherSrl Forest Produ& ICE: X06-019 CENTEX HOMES Model 1577 W Site Information: Project Customer: CENTEX HOMES Lot/Block: 90.9-- Address: q%3 S/ 7,-a,Wy ava-I LfjL City: Ft. Pierce Project Name: Model 1577 W Model: 1577 W Subdivision: Morningside State: FL 51 X06-019 F03 02/01/07 52 X0"19 F04 02/01/07 53 X06-019 F05 02/01/07 �007 ut`y Ft11-C.tii:Lf.lrslTrj�lll N0 67, '®•, STA E OF •� FL Lic #4676�1-,,�'a`�S:rl 0 R seng-chai Tan, 345 Alhambra PL it s�(�AfAI'�\ `• r Y West Palm Beach, FL 33405 ail MITek Industrie -tm l��l"rvn nlnO����� FLcert,#663A FEB 0" 1 2007 A WARNING - Ver4Jy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. 14515 N. Outer Forty, W Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consuit'ANSI/TPIi Quality Criteria, DS&89 and BCS11 Building Component M iTek® Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSII . 0_,hd 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z cz-a materials on inadequately braced trusses. WEBS c3� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate �,� �,�� 3 Cc other interested parties. plates 0 -1/16" from outside O O =1a6 19 v 4. Cut members to bear tightly against each other. edge of truss. EL 5. Place plates on each face of truss at each joint and c7-8 csa ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MITek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE i AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the, length parallel 10. Plate type, size, orientation and location dimensions to slots, CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14, Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, 14 Installing & Bracing of Metal Plate 1 ® © 2004 Mitek® Connected Wood Trusses. Job Truss Truss Type Oty Ply Centex Homes, Model 1577 A X06-019 A01 COMMON 1 1 Job Reference Universa(jvU*l Product, Inc. E359, Ft Pierce, Fl. 34946, James L Shoaf 6.300 s Dec 1 2005 MTek Industries, Inc. Thu Feb 01 08:03. 7 Page 1 7-8-11 14-9-10 21-10-9 29-7-4 , 7-8-11 7-0-15 7-0-15 7-8-11 Scale=1:49 Us = S00 12 4 i 1.5x4 3 6 1Sx4 4 2 W 1 6 2 W 1 7 I 4x6 3x10 11 10 9 8 3x10 11 3x4 = 3x4 = 1-4-0 O_g.90-7-4 ,1-9-0 10-3-12 19-3-8 28-3-4 2$-7+-4 , 1-0-0 8-11-12 8-11-12 8-11-12 04-0 04-0 1-M Plate Offsets 1:0.0-14 E 1:0-0-41-514 :0-0.14 E :0-0-41-5.14 LOADING (psf) SPACING 24)-0 CSI DEFL in poc) Well L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.93 Vert(LL) -0.22 7-8 >999 360 MT20 2441190 TCDL 15.0. Lumber Increase 125 BC 0.94 Vert(TL) -0.71 7-8 >487 180 BCLL 10.0 Rep Stress Ina YES WB 0.22 Haz(TL) 0.11 7 n/a n!a BCDL 10.0 Corte FBC20041TPI2002 (Matrix) Weight: 135 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 333 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 74-5 oc bracing. WEBS 2X4SYP No.2 WEDGE Left, 2 X 8 SYP SS, Right: 2 X 8 SYP SS REACTIONS (lb/sae) 1=1302/0-M, 7=1302/0-8-0 Max Hcrz1=102(load case 5) Max Uplift1=370(load case 5), 7=370(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=2577/725, 2.3=2251/635, 34=2150/656, 4-5=2150/656, 5$=2251/635, 6-7=2577f725 BOT CHORD 1-10=-688/2299, 9-10=339/1559, 8.9=-339/1559, 74=—W6/2299 WEBS 2-10=516/320, 4-10=245/752, 4.8=245/752, 6-8=516/320 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-sexend gust); h=20R; TCDL=4.2psf, BCDL=3.Opsf Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60. 3) 'This buss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 3x6 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable dwithstanding 370 lb uplift at joint 1 and 370 lb uplift atjoint 7. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 1/16" O * For 4 x 2 orientation, locate 001) plates 0 - 1/16" from outside a. edge of truss. R *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output, Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 0 WNW.i TEE-LOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. � 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1, 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Miteko Job Truss Truss Type oty Ply Centex Homes, Mode11577 A X06.019 A02 HIP 1 1 Job Reference foDfionall Universa��t Product, Inc. E359, Ft Pierce, Fl. 34946. James L Shoal 6.300 s Dec 12W5 M Tek Industries, Inc. Thu Feb 01 08: 7 Page 1 6-10-9 13-6-0 16-1-4 22-8-11 29-7-4 6-10-9 6-7-7 2-7-4 6-7-7 6-10-9 Scale =1:49. 46 = 46 = 4 5 5.00 12 3 6 W2 W2 2 7 1 6 � I$ US — 3x5 = 14 13 12 11 10 9 3x6 II 1.5x4 II 5x6 = 1.5x4 II 3x6 ll �1,f-�4-0 0%7-4 ,1-trt� -40 6-10-9 13-6-0 16-1-4 22-8-11 28-3-4 2$ 7i-4, 1-0-0 5-6-9 6-7-7 2-7-4 6-7-7 5-6-9 04-0 0-4-0 1-" Plate offsets 4:0-M.0-2-41,[5.0-3-0,()-241,[9:0-M,O-"],[11.0.M,0.341,[14:0-1-11.0-0-121 LOADING (pso SPACING 2.0.0 CSI DEFL in (loc) Wall L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.87 Vert(LL) 0.21 12-13 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.26 BC 0.71 Vert(TL) -0.60 12-13 >539 180 BCLL 10.0 Rep Stress Incr YES WB 0.37 Horz(TL) 0.08 9 n/a n/a BCDL 10.0 Code FBC2004fTP12002 (Matra) Weight 137lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 'Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. T2 2 X 4 SYP No.2 BOT CHORD Rigid calling directly applied or 9-0-4 oc bracing. BOT CHORD 2X4SYP SS WEBS 2 X 4 SYP No.2 REACTIONS (lb/stze) 14=1332/0-8-0, 9=1332/0-8-0 Max Horc14=93(load case 5) Max Upliftl4=422(load case 5), 9=-422(load case 6) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=-1791/407, 2-3=-2050/549, 3-0=1672/443, 4.5=1476/443, 5-6=1674/443, 6-7=2049/549, 7.8=1790/408 BOT CHORD 1-14=-416/1791, 13-14=509/1791, 12-13=-609/1791, 11-12=282/1476,10-11=-416/1790, 9-10=416/1790, 8.9=416/1790 WEBS 3-13=39/133, 3-12---450/248, 4-12=58/316, 5-11=59/315, 6.11=448/248, 6-10=-41/131, 2-14=738/312, 7-9=737/312 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02;130mph (3-second gust); h=2tft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcunennt with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 422 lb uplift atjoint 14 and 422lb uplift at joint 9. LOAD CASE(S) Standard e WARNING - Verify design and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, parameters Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite N300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrto Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. 0- OP Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in Welk 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection, dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15, Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Mitek® Connected Wood Trus$es. Job Terse Truss Type Qly Model 1577 A X06-019 A03 HIP 1 I 17ICerexHomes, Reference o tonal Universe(€q*t Product, Inc. E359, FZ Pierce, Fl. 34946. James L Shoaf 6.300 s Dee 1 2005 M ITek Industries, Inc. Thu Feb 01 08: 7 Page 1 • 6-3-5 1340-0 16-7-4 23-3-15 29-7-4 , , 6-3-5 6-8-11 3-7-4 6-8-11 6-3-5 Scale =1:49. 46 = Us = 4 5 5.00 12 3 6 W2 W2 2 7 1 8 134 I$ US — 3x5 = 15 14 13 1211 10 9 3x6 11 1.5x4 If 3x6 = 1.5x4 11 3x6 11 14-0 J%--71 ,106-3-5 13-M 16-7-4 23-3-15 28-3-4 2$-7,-4 , --40 1-" 4-11-5 6-8-11 3-7-4 6-8-11 4-11-5 04-0 0-4-0 1-0-0 Plate Offsets 4:030 0-2-45:0.3-00-2-4 9:030 0.0-1 15:0-1-11 0-0-8 LOADING (psf) SPACING 2-0.0 CSI DEFL in (loc) 11defl L/d PLATES GRIP TCLL 20.0 Plates Increase 125 TC 0.84 Vert(LL) -0.25 10-11 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC. 0.73 VerM) -0.64 10-11 >506 180 BCLL 10.0 Rep Stresslncr YES WB' 0.33 Haz(TLf 0.08 9 nnla rda BCDL 10.0 Code FBC2004/TPI2002 (Matra) Weight. 136 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 'Except' TOP CHORD Structural wood sheathing directly applied or 2-10-9 oc pudins. T2 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 8-11-9 oc bracing. BOT CHORD 2 X 4 SYP SS WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 15=1332/0-8-0, 9=1332/0.&0 Max Horz15-90(load case 5) Max Upliftl5=418(load case 5), 9=-418(load case 6) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1794/418, 2-3=2040/544, 3-0=1702/446, 4-5=1519/450, 5-6=1702(446, 6-7=2040/545, 7-8=1794/419 BOT CHORD 1-15=-419/1786,14-15=509/1786, 13-14= 509/1786, 12-13=286/1519, 11-12=286/1519, 10-11=-419/1786, 9-10=-419/1786, &9=-419/1786 WEBS 3.14=-W111, 3-13=-006/240, 4-13=-42/312, 5-11=-421312, &11=-006/240, 6.10-6Vl l 1, 2-15=705/278, 7-9=705/278 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02;130mph (3-second gust); tt=2W, TCDL=4.2psf; BCDL=3.0psf: Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 418 lb uplift at joint 15 and 418 lb uplift at joint 9. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES oN Tins AND REVERSE SD7E BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 ,Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-1/16° rr O *For 4 x 2 orientation, locate v plates 0 - 1/16" from outside a edge of truss. OR *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4. X 4. perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wgod Trusses. - Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 40cak, ■ AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties, O U 4. Cut members to bear tightly against each other. CL 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 190/6 at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15, Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® 0 Job Trues Tniss Type Qty Pty Ceniax Homes, Model 1577 A X06.019 A04 HIP 1 1 Pb Reference fbnal Universa�"t Product Inc. F_359, FL Pierce, R. 34948, James L.Shoat 8.300 s Dec 12005 MTek Industries, Inc. Thu Feb 01 08: 7 Page 1 14-01 5-9-4 11-" 18-1-4 23-10-0 28-3-4 ,29-7-4� 1-4-0 4-5-4 5-8-12 6-7-4 5-8-12 4-5-4 1-4-0 Scale =1:49. rv,e = 5x6 = q 6 5.00 12 3 W1 6 >tL 3x6 11 � 3n6 11 2 � 1 9 � I$ 3x5 = 3n5 = 15 14 13 12 11 10 9 1.5x4 II 3x6 = 3z8 = 1.5x4 II Q-0-O nn1-4-0 ,1-I�tF-0 5-9-4 11-6-0 18-1-4 23-10-0 1 28-7-4 29-7-4 1-0-0 45-4 5-8-12 6-7-4 5-8-12 4-9-4 1-0-0 0-4-0 Plate offsets 2:0-1-11 0-0.8 4:0-3-4 0.2-8 5:a2-12 0-2-8 :0-3-00.0-1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.82 Vert(LL) -0.16 10-11 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase •_ 1.25 BC 0.70 Vert(TL) -0.48 13-14 >672 ' 180 BCLL 10.0 Rep Stress Irxx YES WB 0.14 Horz(TL) 0.07 9 Na Na BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight 141 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 'Except TOP CHORD Structural wood sheathing directly applied or 3-1-0 oc pudirls. T2 2 X 4 SYP No.2 BOT CHORD Rigid cetling directly applied or 95-14 oc bracing. BOT CHORD 2 X 4 SYP SS WEBS 2 X 4 SYP No.2 REACTIONS (lb(size) 15=1332/0$-0, 9=1332/0-8-0 Max Horz 15=80(load case 5) Max Upliftl5=406(load case 5), 9--406(load case 6) FORCES (lb) -Maximum CompressiortlMaximum Tension TOP CHORD 1-2=17341392, 2-3=-1981/496, 3-0=1823/510, 45=1650/508, 5-6=-1823/510, 6-7=1981/497, 7-8=1734/392 BOT CHORD 1-15=387/1727, 14-15=-456/1727, 13.14=-456/1727,12-13=350/1650,11-12=350/1650,10-11=388/1727, 9-10=-388/1727, 8.9=388/1727 WEBS 2-15=708/268, 3-14=104/85, 3.13=121/144, 413-301311, 411=149/149, 5-11=29/311, 6-11=121/145, 6-10=104/85, 7-9=708/268 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second grit); 11=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed fora 10.0 pal bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 406 lb uplift at joint 15 and 406 lb uplift atjoint 9. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer -not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/14 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e,g. diagonal and Securely Seat. or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2, Never exceed the design loading shown and never stack c,-2 c2.3 materials on inadequately braced trusses. WEBS 4 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate T0 other interested parties, plates 0 - 1/16" from outside O L1a6 1 U 4. Cut members to bear tightly against each other. edge of truss. IL 5. Place plates on each face of truss at each joint and c7-8 csa ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates, the environment in accord with ANSI/TPII . 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice fi' 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft, spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate imax, © 2004 Miteke Connected Wood Trusses. Job Truss Oty Homes, Model 15TI A XO6-019 A05 ]7SPECT: 1 r7ntex Reference Clonal Univers4fot8st Product, Inc. E359, Ft. Pierce. R. 34948. James L Shoaf 6.300 s Dee 1 2005 Wok trdustriea, Inc. Thu Feb 01 08:0 7 Page 1 1-" 6-2-0 11-0-0 13-7-10 17-5-12 18-7 4 20-10-8 , 24-0-14 28-3-4 29-7-4, 14-0 4-10-0 4-10-0 2-7-10 3-10-2 1-1-8 2-3-4 3-2-6 4-2-6 1-4-0 Scale = 1:49. 46 = 3x4 = 1.50 11 4x6 c 4 5 6 7 5.00 12 1.5xg II 1.5t[4II W1 5 W6 3 W7 4 9 W8 3x6 II 1 3x6 11 2 W2 9 10 1 rvc8 = 6x8 — 11 H. R4 ffd - �gd iii. 21 20 19 1s 17 14 13 12 3x4 = 3x6 = 3x10 = 1.5x4 11 14-0 0�7-4 r1 -0 6-2-0 11-" 13-7-10 , 17-5-12 18-7-4 20-10-8 24-0-14 28-3-4 24-7,-4 , 1-0-0 4-10-0 4-10-0 2-7-10 3-10-2 1-1-8 2-3-4 3-2-6 4-2-6 0-" 0-4-0 Plate Offsets 2:0-1-11 0-0-1 . 4:03d 0-1-1 :03-00-1-8 10:0-3-00.0-12 13:0.1-12 0.1-8 15:0-2-0E 16:0-2-0 03-018:0-2-4 0.1-8 LOADING (psi) SPACING 2-0-0 CS! DEFL in (toe) Wall Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.87 Vert(LL) -0.19 18-20 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.68 Vert(TL) -0.62 18-20 >520 180 BCLL 10.0 Rep Stress Incr YES WB 0.34 Hmz(TL) 0.13 12 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matron) Weight 165lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 'Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purtins. T2 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 9-15 4 oc bracing. BOT CHORD 2 X 4 SYP No.2 *Except* B12X4SYP SS.B62X4SYP SS WEBS 2X4SYP No.2 REACTIONS (lb/size) 21=1332/041.0, 12=1332/0-8-0 Max Horc21=76(load case 6) Max Uplifl2l=-401(load case 5),12=-401(load case 6) FORCES (lb) - Maximum CompressioNMaximum Tension TOP CHORD 1-2-1746/398, 2-3=2010/505, 3-4=1927/569, 4-5=1769/546, 5.6=2366/682, 6-7=2378/681, 7.8=3045/822, 8-9=3006i778, 9-10=1892/482, 10.11-1645/382 BOT CHORD 1-21=396/1748, 20-21=-034/1748, 19.20=365/1628, 18.19=-365/1628, 17-18=16/39, 16-17=0/20, 6-16=196/97, 15-16=-490/2252, 14-15=26/157, 8-15=-271/131, 13-14=-46/184, 12-13=378/1639, 11-12=378/1639 WEBS 2-21=761/292, 3-20=172/184, 4-20=149/204, 4-18=-65/390, 5-18=720/221, 16-18=-003/1838, 5-16=184/800, 7-16=107/431, 7-15=272/887, 13-'15=364/1588, 9-15=262/1188, 9.13=-8741243, 10-12=709/279 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20fl; TCDL=4.2psF, BCDL=3.OpsF, Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x5 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 401 Ill, uplift at joint 21 and 401 lb uplift atjoint 12. LOAD CASE(S) Standard A WARNING - Vertfg design and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 parameters Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated, 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z c2-3 materials on inadequately braced trusses. WEBS �,� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate �,� 3 �,�� 3 other interested parties. plates 0 -/ib" from outside 0 O 4. Cut members to bear tightly against each other. edge of truss. EL 5. Place plates on each face of truss at each joint and c7-8 csa ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted,.moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice X perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10, Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16, Install and load vertically unless indicated otherwise. Industry Standards: I ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, MEMO Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Job Truss Truss O O Type l]ly Ply Centex Homes. Model 1577 A X06-019 A08 HIP 1 1 Job Reference Tlonal Univers�Eg[�t Product, Inc. E359, FL Pierce, Fl. 34948, James L Shoat 6.300 s Dec 1 2005 MTek Industries, Inc. Thu Feb 07 08:03:3 Symbols Numbering System 'AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/q *Center plate on joint unless x,y Damage or Injury offsets are indicated, 6-4-8 dimensions shown in ft-in-sixteenths .Personal Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1. 0"'/'6" 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 c2-3 materials on inadequately braced trusses. WEBS �a� 4 3. Provide copies of this truss design to the building 0 o designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate 5 X �,�� � m other interested parties, p plates 0 - 1/16" from outside 0 O �As U 4. Cut members to bear tightly against each other. edge of truss, a. 5. Place plates on each face of truss at each joint and c7-8 csa ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates, the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice fi' 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots, CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11, Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12, Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. If indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss'Construction. MiTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Job Truss Type Oty Ply Homes, Model 1577 A JTruss X0"lg A07 SPECIAL 1 1 [Co'ab�Reference o tional Univers4FGrW Product, Inc. E359, Ft Pierce, Ft. 34946, James L Shoaf 6.300 s Dec 1 2005 MTek austries. Inc. Thu Feb 01 08:0 07 Page 1 14-0 , 5-8-11 94)-0 13-0-1 17-5-12 20-74 , 24-0-13 , 28-3-4 129-7-4, 1-4-0 44-12 3-3-5 4-0-1 4-5-11 3-1-8 3-5-9 4-2-7 1-4-0 Scale=1:49. 5x7 = 3x6 It 1.5x4 II 46 = 4 5 6 7 8 5.00 12 1.5x4 J W1 W5 3 9 :; 4 W7 3x6 11 6 3x6 I I 2 W2 8 10 1 502= 500= 11 20 19 18 17 14 13 12 5x5 = 3x10 = 2x5 I I 3c4 It 14-0 0_307-4 ,1---6-0 9-0-0 13-0-1 1 17-5-12 20-10-8 1 24-0-13 28-3-4 2$-7,-4 , 1-0-0 7-8-0 4-0-1 4-5-11 3-4-12 3-2-5 4-2-7 0-4-0 0-4-0 1-0-0 Plate Offsets 2:0-1-110-1-0 4:05.4 0-2-1 10:0.3-00-0-1 13:0-1-12 0.1-0 15:0.&l 0.1.816:0-0-4 0-2.4 18:0-2-00-1-8 19:0-2-8 03-0 LOADING (psf) SPACING 2.0-0 CS! DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.67 VwKLL) -0.21 15-16 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.86 Vert(TL) -0.58 15.16 >553 _180 BCLL 10.0 Rep Strew Inca YES WB 0.39 Horz(11) 0.16 12 n/a n/a BCDL 10.0 Code FBC2004/rPI2002 (Matrbc) WeigM:1561b LUMBER BRACING TOP CHORD 2 X 4 SYP SS 'Except' TOP CHORD Struidural wood sheathing directly applied or 337 oc pudins. T2 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-6 4 oc bracing. BOT CHORD 2 X 4 SYP No.2 'Except' B1 2 X 4 SYP No.1, B6 2 X 4 SYP SS WEBS 2X4SYP No.2 REACTIONS (lb/sae) 20=1332/0.8.0,12=133210.&0 Max Horz20= 62(load case 6) Max Uplifl20=390(load case 3), 12=390(load case 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=16681428, 2-3--1997/574, 3-0=18981571, 45=21261692, 5-0=-3139/959, 6-7=31611W, 7$=2768030, 5-9=3136/890, 9-10=-1899/525,10-11=1649/420 BOT CHORD 1-20=-451/1716, 19-20=- 54/1716, 18-19=-431/1751, 17-18=27/128, 16-17=0/96, 6-16=222(126, 15-16=708/2821, 14-15=28/153, 8-15=123/604, 13-14=41/146,12-13=.417/1645, l l-12--417/1645 WEBS 2-20=924/360, 3-19=0/163, 4-19=-42/138, 4-18=195/576, 5.18=-868/305, 16-18=566/2090, 5-16=309/1166, 7-16=-165/532, 13-15=-417/1657, 9-15=327/1286, 9-13=93B/281,10-12=717/271 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2ps ,, BCDL=3.0psf•, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed: Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4)'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x5 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 390lb uplift at joint 20 and 390 lb uplift at joint 12. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/14 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 -1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates, * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots, LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output, Use T, I or Eliminator bracing If indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but aF reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction, DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 Ir O 2 U roil ti Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all Cc other interested parties. O U 4. Cut members to bear tightly against each other. d 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified, 12, Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty ply Centex Homes, Model 1577 A X06-019 AO8 HIP 1 1 Job Reference (optional) UnlversoFaWt Product, Inc. E359, FL Pierce, Fl. 34946. James L Shoaf 6.300 s Dec 12005 AhTek Industrkas, Inc. Thu Feb 01 08:03USM7 Page 1 7-0-0 11-8-9 17-10-11 22-7-4 , 29-7-4 , 7-0-0 4-8-9 6-2-2 4-8-9 7-M Scale =1:49. 6x8 = 6x8 = 5.00 12 2 11 12 3 13 14 15 4 16 17 5 72 1 W W2 1 6 �EEJ I$ 5x10 i:� 10 18 19 20 9 8 21 22 23 7 Sx10 3x10 11 3x6 = 5x10 MT18H= 3x6 = 3x10 11 0-0-0 0-" ,1-04 7-0-0 14-9-10 22-7-4 i 28-7-4 29-7 4 1-M 6-0-0 7-9-10 7-9-10 6-0-0 Plate Offsets 1:0-1-01-7-14 1:05-9 0-2-8 2.G 4-0 0 2- 5:0-0-00.2- 6:0-1-0to-14 6:059 0-2-8 :0-2-12 0-1-8 10:0.2-12 0-1-8 LOADING (psf) SPACING 2-0-0 CS! DEFL in (loc) Well L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.98 Vert(LL) 0.25 9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.88 Vert(TL) -0.66 9.10 >525 180 MT18H 244/190 BCLL 10.0 Rep Stress [nor NO WB 0.78 Ha z(TL) 0.16 6 n/a Na BCDL 10.0 Cade FBC2004ITP12002 (Matrix) Weight 167 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2'Exoept' TOP CHORD Structural wood sheathing directly applied or 2-3-15 oc puriins. T2 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 5-8-2 oc bracing. BOT CHORD 2 X 6 SYP SS WEBS 2X4SYP No.2 WEDGE Left: 2 X 6 SYP SS, Right: 2 X 6 SYP SS REACTIONS (lb/size) 1=2256/0-8.0, 6=2256/0-8.0 Max Horz 1=47(load case 5) Max Uplift1=753(load case 4), 6=757(load case 6) FORCES (lb) - Maximum CompressionWaximum Tension TOP CHORD 1-2=5198/1795, 2-11=-4771/1709, 11-12=-4772/1709, 3-12=-4774/1709, 3-13=-6407/2274, 13-14=-6407/2274, 14-15=-6407/2274, 4-15=6407/2274.4-16=-4775/1698, 16-17=-0772/1697,5-17=4771/1697,66=-5198/1782 BOT CHORD 1-10=1597/4702, 10-18=2213/6214, 18-19=2213/6214, 19-20=2213/6214, 9-20=2213/6214, 8-9=-2207/6214, 8-21=2207/6214, 21-22=-2207/6214, 22-23=2207/6214, 7-23=2207/6214, 6-7=1SM4702 WEBS 2-10=396/1404, 3-10=1804/702, 3-9=0/448, 4-9=0/448, 4-7=1820/710, 5-7=-401/1413 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 3x4 MT20 unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 753lb uplift at joint 1 and 757 lb uplift at joint 6. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 227lb down and 131 lb up at 7-", 104 lb down and 75 Ib up at 9-0-12, 104 lb down and 75 lb up at 11-0-12, 104 lb down and 75lb up at 13-0-12, 104lb down and 75 lb up at 14-9-10, 104 lbdown and 75 lb up at 16-6.8, 104 lb down and 75 lb up at 18-6-8, and 104 lb down and 75 lb up at 20-6.8, and 187 lb down and 131 lb up at 22-7-4 on top chord, and 248 lb down and 661b up at 7-0-0, 641b down at 9-0-12, 641b down at 11-0-12, 64lb down at 13-0-12, 64 lb down at 14-9-10, 64lb down at 16-6-8, 64Ib down at 18-6-8, and 64 Ib down at 20.E-8, and 248 Ib down and 66 Ib up at 22-6.8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Irxxease=1.25 Uniform Loads (plf) Vert: 1-2=70, 2-5=70, 5-6=-70,1-Cr-20 Concentrated Loads (lb) A WARNDY - Verify d ign pa am21 ete andJVA2N-JWJON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design 1s based only upon parameters shown, and 1s for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofdo Drive, Madison, WI 63719. Symbols PLATE LOCATION AND ORIENTATION 13/, * Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. O'1�16" 0 O * For 4 x 2 orientation, locate X plates 0 - 1/16" from outside o edge of truss. OR *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing If indicated. BEARING Indicates location where bearings t�w (supports) occur. Icons vary but reaction section Indicates joint 9F number where bearings occur. Industry Standards: ANSI/TPI1; National Design Specification for Metal Plate Connected Wood Truss Construction, DSB-89: Design Standard for Bracing. BCSI1; Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wpod Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0OK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber. is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13, Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss pet]ly Py Centex Homes, Model 1577 A X06-019 A09 TSPEC:L 1 1 Job Reference (optional) Universal FgMttjroduct, Inc. E359, FL Pierce, Fl. 34946, James L Shoat 6.300 s Dec 1 2005 MTek mustries, Inc. Thu Feb ' 3:37 2007 Page 1 28-3-4 3-10-13 7-6-0 12-0-4 17-7-0 22-1-4 264!1-12 2a 8-1,2 , 301:A , 3-10-13 3-7-3 4-6-4 5.6-11 4-64 4-7-8 1-0-0 24-0 0-6-8 30 = 3x4 = 5.00 12 4 5 6 7 1.6x4 3 W 1 2 10 8 91.5x411 3x7 11 10 Jw 4 W5 11 1 15;2 j$ 3x6 = 3x4 = 18 17 16 15 14 13 19 12 3x8 = 3x4 = 3x8 = 3x4 = 1-�-U-0 7-6-0 14-9-10 22-1-4 26-8-12 ,28-3-4,�0.7-4 , r—r 1-" 6-8-0 7-3-10 7-3-10 4-7-8 1-6-8 2-M 0-4-0 Plate Offsets 1:0-0 6 0-0.2 2:0-3-12 0-1-89:0-3-00-1-1 LOADING (psi) SPACING 2-0-0 CSI DEFL in (loc) I/defi L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.79 Vert(LL) -0.15 16-17 >999 360 MT20 244/190 TCDL 15.0 •_ Lumber Increase 1.25 BC 0.83 Vert(TL) -0.45 16-17 >714 180 BCLL 10.0 Rep Stress Ina NO WB 0.36 Horz(TL) 0.10 12 Na rrla BCDL 10.0 Code FBC2004RPI2002 (Matrix) Weight: 148lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 'Except' TOP CHORD Structural wood sheathing directly applied or 3.8-6 oc purlins. T1 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 6-" oc bracing. BOT CHORD 2 X 4 SYP N0.2 WEBS 2X4SYP No.2 REACTIONS (Ib/s¢s) 12=2028/0-8.0, 18=1338/0.8.0 Max Horz18=52(load case 5) Max Upliftl2--635(load case 4), 18=410(load case 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-1419/392, 2-3=1814/542, 3-4=2020/613, 45=1881/603, 5.6=2565/822, 6-7=1916/619, 7-8=2111/637, 8-9=1403/422, 9-10=-W50, 10-11=129/155 BOT CHORD 1-18=-417/1502, 17-18=-419/1502, 16-17=728/2481, 15-16=739I2505,14-15=739/2505,13.14=-424/1540, 13-19=129/524, 12-19=129/524,11-12=105/133 WEBS 3-17=99/452, 4-17=74/402, 5-17=-BW/290, 5-16=0/216, 6-16=0/192, 6-14=788/287, 7-14=102/48B, 8-14=13M97, 8-13=1176/386, 9-13=-442/1553, 9-12=1557/424, 10-12=306/169, 2-18=1095/382 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf,, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 635 lb uplift at joint 12 and 410 lb uplift at joint 18. ' 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 335 lb down and 89 Ib up at 2741-12 on top chord, and 277 lb down and 73 lb up at 27-8-12 on bottom chord. The desigNselection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=70, 4-7=70, 7-8=70, 8-9=70, 9-11=70, 1-11=20 Concentrated Loads (lb) Vert: 9=335(F)19=277(F) A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite 4300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component MiTel Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside edge of truss. a- R *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output, Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, Is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all pc other interested parties. 0 U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Ply Centex Homes, Model 1577 A XO6-019 A10 SPECIAL 1 1 Job Reference Universal F"tQroduct, Iic. E359, Ft Pierce, R. 34946, James L. Shoal 6.300 s Dec 1 2005 MiTek Industries, Inc. Thu Feb 01 MM 2007 Page 1 28-3-4 , 1-4-0, 7-0-0 11-9-14 17-9-6 22-7-4 26-2-12 27-2-1,2 , 304-4 , e 31:51. 1-4-0 5-8-0 4-9-14 5-11-8 4-9-14 3-7-8 1-0-01-0-8 4x6 = 4x6 = 5.00 12 3 4 5 6 = 4� _ W /1 W 6 1.5A 11 >4x6 3x6 II 9 2 1 10 Ila I$ 3x5 =ffd 16 15 14 13 12 11 4x6 = 3x8 = 3x5 = 1-4-0 20 0 7-0-0 14-9-10 22-7-4 26-2-12 28-3-4 , 30-7-4 , 1-0-0 5-8-0 7-9-10 7-9-10 3-7-8 2-M 04-0 2-M 0-4-0 Plate offsets 2:0-1-'11 0-1-08:D-3-00-1-1 12:0-2-0 0.1-8 LOADING (psf) SPACING 2-0.0 CSI DEFL in (loc) Vdeft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.94 Vert(LL) 0.21.15-16 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.99 Vert(TL) -0.62 15-16 >518 180 BCLL 10.0 Rep Stress Ina YES WB 0.49 Horz(TL) 0.10 11 Na n /a BCDL 10.0 Code FBC2004/fP12002 (Matrix) Weight: 142lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. T1 2 X 4 SYP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2 X 4 SYP No.1 *Except* B2 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb(size) 17=1326/D-8-0, 11=1428/0-8-0 Max Horz 17=49(load case 5) Max Upliftl7=412(load case 3), 11=482(load case 4) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=1739/473, 2-3=2025/606, 3-0=1783/585, 4-5=2702(868, "--1846/603, 6-7=2DO5/622, 7-8=-1306/4ll, 8-9=87/142, 9.10=143/194 BOT CHORD 1-17=-481/1757, 16-17=-482/1757, 15-16=78812610, 14-15=790/2601, 13-14=-790/2601,12-13=397/1416,11-12=178/669, 10-11=141/147 WEBS 2-17=-814/325, 3-16=116/571, 4-16=1045/368, 4-15=0/239, 5.15=0/253, 5-13=942/346, 6-13=-101/458, 7-13=140/473, 7-12=1080/348, 8-12=369/1255, 8-11=1385/417, 9-11=205/126 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; E xp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10:0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x4 MT20 uNess otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 412lb uplift atjoint 17 and 482lb uplift at joint 11. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 Ir O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBEREDAETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO SBCCI BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 96-31, 95-43, 96-20-1, 96-67, 84-32 4922,5243,5363,3907 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury I . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. a_ 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others, 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Ply Centex Homes, Model 1577 A X06-019 A11 HIP 1 1 Job Reference (optional) Univers#F(y[®st Product, Inc. F_359, FL Pierce, Fl. 34946, James L Shoal 6.300 s Dec 12005 IufTek Industries, Inc. Thu Feb 0 :39 2007 Page 1 10-2-7 15-3-3 20.4-13 25-7-4 , 28-3-4 30174 5-0-0 5-2-7 5-0-11 5-1-10 5-2-7 2-8-0 24-0 Seats =lsl sxto = sxlo = s.00 12 3xa = axe = 3xa = � 2 17 18 3 19 204 5 21 22 6 23 2425 7 3x7 3 3 W W 8 W 1 9 � I$ 3x4 = 3x70 = 16 26 27 15 28 29 14 13 30 31 12 32 3334 11 10 3x8 II 3x6 = 5x6 = 30 = 3x6 = 3x8 = 0-0-0 30-7-4 ,1-0-Q 5-0-0 10-2-7 15-3-3 20-4-13 25-7� 28-3�$-7,- 24 , r 1-0-0 4-0-0 5-2-7 5-0-11 5-1-10 5-2-7 2-8-0 04-0 2-0-0 Place offsets 1:0-1-121-0-11 1:0-115 0-1- 2:0-2-12 0-3-8 s:a1-1 0-1-8 :0.3-8 03$ a:0-3-00-1-8 11:0-2-00-1.8 12:0-1-120-1-8 14:0-2-00-1.8 15:0-1-12 0-1-8 LOADING (psi) SPACING 2-0-0 CSI DEFL in (lac) Vdefi Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.66 Vert(LL) 0.27 14-15 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.59 Vert(TL) -0.65 14-15 >512 180 _ BCLL 10.0 Rep Stress Irxx NO WB 0.53 Horz(1L) 0.09 10 Na Na BCDL 10.0 Code FBC2004lTPI2002 (Matra) Weight: 183 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 3-2-7 oc purlins. T2 2 X 6 SYP SS, T3 2 X 6 SYP SS BOT CHORD Rigid calling directly applied or 6-0-0 oc bracing. BOT CHORD 2 X 6 SYP SS WEBS 2X4SYP No.2 WEDGE Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 10=1802/0-8-0, 1=1571/0�" Max Horz 1 =33(load case 5) Max UpIift10=709(load case 4), 1 =-552(load case 3) FORCES (Ib) -Maximum CompressioNMaximum Tension TOP CHORD 1-2-�a87/1319, 2-17=5236/2027, 17-18=5236/2027, 3-18=5238/2027, 3-19--5677/2204, 19-20=-5677/2204, 420=5677/2204, 45=5677/2204, 5-21=5677/2204, 21-22=v677/2204, 6-22=-5677/2204, 6-23=-0611/1812, 23-24=-460911812, 2425=-4609/1812, 7-25=-4609/1812, 7-8=2155/840, 8-9=94f72 BOT CHORD 1-16=1173/3242,16-26=1172/3255, 26-27=1172/3255, 15.27=117213255, 15.28=1961/5236, 28-29=1 961/5236,14-29=1961/5236, 13-14=1746/4609, 13-30=1746/4609, 30.31=1746/4609, 12-31=-1746/4f>09, 12-32=712/1933, 32-33=71211933, 33-34=712/1933, 11-34=-712/1933, 10.11=38/103, 9.10-38/103 WEBS 2-16=0/287, 2-15=-84612191, 3-15--&66/342, 3-14=190/487, 5-14=-440/247, 6-14=-429/1145, 6-12=918/446, 7-12=1121/2875, 7-11=562/289, 8-11=$02(2116, 8-10=-1626/617 NOTES 1) Unbalanced roof live loads have been considered for this design. -- - 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 2x5 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 709 lb uplift at joint 10 and 552 lb uplift at joint 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)124 lb down and 87 lb up at 540.0, 36 lb down and 421b up at 7-1-1, 36 lb down and 42 lb up at 9-1-1, 36 lb down and 42 lb up at 11-1-1, 36 lb down and 42 lb up at 13-1-1, 36 lb down and 42 lb up at 15-1-1, 36 lb down and 42 lb up at 17-1-1, 36 lb down and 42 lb up at 19-1-1, 36 lb down and 42 lb up at 21-1-1, 36 lb down and 42 lb up at 23-1-1, and 36 lb down and 42 lb up at 23.6-3, and 15 lb down and 541b up at 25-7-4 on top chord, and 43 lb down at 5.0-0, 22 lb down at 7-1-1, 22 lb down at 9-1-1, 22 lb down at 11-1-1, 22 lb down at 13-1-1, 22 lb down at 15-1-1, 22 lb down at 17-1-1, 22 lb down at 19-1-1, 22 lb down at 21-1-1, 22 lb down at 23-1-1, and 22 lb down at 23-6-3, and 14 lb down at 25-6-3 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) 0 WA�9>tl1>Zrij�d�li6�86�r8ta+�t(�/'INQT�� ��F§ >P��i��'P122=-36(F123=36(F) Desigr24a1Y36(15)�g�pefapp�g3aa�j individual building component. 14515 N. Outer Forty, � Suite 4300 Applicability of design parameters and proper incorporation of component Is responsibilidy o building designer -not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Qualify Criteria, DSB-89 and BCSII Building Component M iTe Safetv Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. O O Job Truss Truss Type Oty Symbols PLATE LOCATION AND ORIENTATION 1'/4 * Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 -1/0 from outside edge of truss, *This symbol indicates the required direction of slots in connector plates. OO Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection, dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 'BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek° DSB-89:. Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® ;Connected Wood Trusses. Job TNss Tnrss Type Ply Centex Homes, Model 1577 A X06-019 IB01 10ty COMMON 1 1 Job Reference ti-al UnlversVEgrpt Product, Inc. E359, FL Pierce, Fl. 34946, James L Shoal 6.300 a Dec 1 2005 MTek Industries, Inc. Thu Feb 01 08:03: 7 Page 1 6-" 15-0-0 23.4-0 , 30-0-0 6-8-0 84-0 84-0 6-8-0 Scale =1:49. 5x7 = 5.00 12 4 3 5 1.5x4 Q W 1 W 1 1.5x4 4- 2 6 2 W 1 7 I 4x6 —_ 4x6 = 3x10 ll 10 9 8 3x10 11 3x4 = 3x4 = 14 0 0-" -0 9-8-3 20-3-13 28-8-0 29- 41 1- 84-3 10-7-10 84-3 0-" 04-0 1-M Plate Offsets 1:0-1-0 0-0 1:0- 415-1a :0-1-6 0-0-:0-0-01-5-1a LOADING (psf) SPACING 2-0.0 CS! DEFL in (lox) Well L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.95 Ved(LL) -021 8-10 >999 360 MT20 2441190 TCDL 15.0 Lumber increase 1,25 BC 0.95 •_Vert(TL) -0.63 8-10 >560 180 BCLL 10.0 Rep Stress Inrr YES WB 0.23 Horz(TL) 0.11 7 Na n/a BCDL 10.0 Code FBC2004/rP12002 (Matrix) Weight.• 138lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 34-6 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-2-2 oc bracing. WEBS 2X4SYP No.2 WEDGE Left: 2 X 8 SYP SS, Right: 2 X 8 SYP SS REACTIONS (Ib1/size) 1=1320/0-M, 7=1320/aa o Max Horz 1=104(load case 6) Max Uplift1=375(load case 5), 7=375(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=27191783, 2-3=2344/644, 3-0=2235/663, 45=22351663, 55=-2344/644, 6-7=2719I783 BOT CHORD 1-10=757/2441, 9-10=358/1597, 8-9-- 358/1597, 7-8=-654/2441 WEBS 2-10=541/343, 4-10=220/755, 4-8=220/755, 6-8=541/343 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf: BCDL=3.OpsF, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3)'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 3x6 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 375 lb uplift at joint 1 and 375lb uplift at joint 7. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite N300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-1/0 0 * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside 0 edge of truss. OP *This symbol indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required, See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication, soffware or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension Is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section Indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. O O Job Thus Truss Type Oly Ply Centex Horner, Model 1577 A 3(06-019 802 HIP 1 1 Job Reference UnWerr4F�rWl product, Inc. E359, FL Pierce, Fl. 34946, James L Shoat 8.300 s Dec 1 2005 MTek Industries, Inc. Thu Feb Ot 08:03: Page 1 6-3-5 13-0-0 17-0-0 23-8-11 30-0-0 , 6-3-5 6$11 440-0 6-8-11 6-3-5 Scats =1:48. 4x8 = 4x6 = 4 5 5.00 12 3 6 2 W2 W2 Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 * Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1, 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-x cz•3 materials on inadequately braced trusses. WEBS c3� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all For 4 x 2 orientation, locate 5 �4- 3 cc other interested parties. plates 0 - /ie" from outside O O ��6 v 4. Cut members to bear tightly against each other. edge of truss. 11 12- 5. Place plates on each face of truss at each joint and c7-8 c6-7 ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted, BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others, �Su (supports) occur, Icons vary but 15, Do not cut or alter truss member or plate without prior reaction section Indicates joint approval of a professional engineer. 9F number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Job Thus Type aY Ply Centex Homes, Model 1577 A X06.019 rIB'M 03 HIP 1 1 Job Reference (optional) Universe �t Product Inc.E359, FL Pierce, Fl. 34946. James L Shoat 6,300 s Dec 1 2005 MTek Industries, Inc. Thu Feb 01 08M01007 Page 1 5-6-4 1140-0 15-0-0 19-M 24-5-12 , _ 30-0-0 5-6-4 5-5-12 4-0-0 4-0-0 5-5-12 5-6-4 Scale = 1:50. 3x4 = 4 5 6 12 5.00 12 1.5x4 a ISO 3 10 w 1 7 2 W3 W 6 1 9 . j$ 3x10 = 12 11 10 300 = 3x4 = 3x8 = 3x6 = 3x8 = 3x4 = 0-0-0 0-" ,1-0-0, 1140-0 19-M 29-0-0 30-0-9 1-0-0 104)-0 8-0-0 10-M Plate Offsets 1:0.2-2 0-1-8 9:0-2-2 0.1-8 LOADING (Psf) SPACING 2.0.0 CSI DEFL in (loc) Udell Ud PLATES GRIP TCLL 20.0 Plates Increase 125 TC 0.35 Vert(LL) -0.23 1-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.86 Vert(TL) -0.66 9-10 >534 180 BCLL 10.0 Rep Stress Incr YES WB 0.27 Horz(TL) 0.12 9 nda nda BCDL 10.0 Cade FBC2004/TPl2)W2 (Matrix) Weight 1521b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-9-14 oc purtirs. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 748.6 oc bracing. WEBS 2 X 4 SYP No.2 SLIDER Left 2 X 6 SYP SS 2-6.6, Right 2 X 6 SYP SS 2.6-6 REACTIONS (lb(size) 1=1320/0-8-0, 9=13200" Max Horz 1=76(load case 5) Max Upliftl=342(load case 5), 9=342(load case 6) FORCES (lb) - Maximum Comprawi xVMaximum Tension TOP CHORD 1-2=2697/704, 2-3=2585/719, 3.4=2237/609, 4-5=2011/597, 5.6=2011/597, 6-7=2237/609, 7-8=2585f719, 8-9=2697/7D4 BOT CHORD 1-12-669/2428, 11-12=.493/2096, 10-1 l=-393/2096, 9-10=.607/2428 WEBS 3.12=-476/292, 4-12-69/496, 5.12=265f79, 5-10=265/79, 6.10=-69/496, 7-10=-4761292 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water pondirg. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 46 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable ollwithstan ding 342 lb uplift at joint 1 and 342lb uplift at joint 9. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Desgn valid far use, city with MTek cwnectors. This design is based a* upon parameters shown, and is for an Individual building component. Suite #300 ApplIcabililyofdesign parameters and proper inic6poration of component is respombft of building designer- not truss designer, Bracing shown Chesterfield, MO 63017 is far klterd support of 91dividuall web members orlly.Additional temporary bracing to insure stability during construction is the responsibility of the erector. Addiiond pent►anent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding tab-0111orl, qucW Control storage, delivery, erection and braci l consult ANSI/fPII Quality Criteria, DSB-89 and BCSII Building Component Safety 6st—W Twn --Vabb from Truss Plate Inst fute, 583 D'Onofno Drive, Madison, WI 53719. 1 Wel Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property �3/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e,g. diagonal and securely seat. or X-bracing, is always required. See BCSiI . 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 c2-3 materials on inadequately braced trusses. WEBS 4 3. Provide copies of this truss design to the building cc 0 designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate N �,3 �� 0 DC�-61 other interested parties. p plates 0 - /16" from Outside O 4. Cut members to bear tightly against each other. edge of truss.5. Place plates on each face of truss at each joint and c7-e cs-aO� embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. If Indicated, ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur, Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. BCSI1; Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate B © 2004 Mitek® Connected Wood Trusses. Job Job Truss Truss Type Ply Centex Homes, Model 1577 A B04 SPECIAL 10ty 1 1 Job Reference nal Universal F"ifroduct, Inc. E359, Ft Pierce, Fl. 34946, James L Shoal 6.300 s Dec 1 20051r1iTek trdustries, Inc. Thu Feb 01 08:03:4 Page 1 5-11-14 11-9-0 14-" 21-M 25-6-14 30-M J . 5-11-14 5-9-2 2-9-0 6-8-0 4-6-14 4-5-2 Scale=1:50.1 4x6 = 4 5a = 5x7 zz 6.00 12 5 6 1.5x4 3 W 1.5x4 W4 7 5 2 W 8 1 9 � I$ 15 14 13 12 11 10 3x4 = 4x6 = 3x8 = 3u7 11 -0 7-11-2 14-6-0 21-0-0 28-M 2"-0 , i 1-0-0 6-7-3 6-6-14 6-" 7-8-0 0-4-0 0-" 1-0-0 Plate Offsets 5:0-5-40-2-1 9:0-0-6 0.0 10:038 0-1-015:0-1-11 0-1-0 LOADING (psf) SPACING 2-M CS! DEFL in (loc) Udell L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.84 Vert(LL) -0.19 11-13 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 1.00 Vert(TL) -0.55 13-14 >601 180 BCLL _ 10.0 Rep Stresslnrx NO WB 0.42 Horz(TL) 0.09 10 n/a nla' ' BCDL 10.0 Code FBC2004/rP120O2 (Matrix) Weight: 143 lb LUMBER BRACING TOP CHORD 2 X4 SYP SS'ExcepY TOP CHORD Structural wood sheathing directly applied or 3.4-5 oc purlins. T2 2 X 4 SYP No.2, T3 2 X 4 SYP No.2 BOT CHORD Rigid riling directly applied or B313 oc bracing. BOT CHORD 2 X 4 SYP SS'ExcepY B2 2 X 4 SYP No.2 WEBS 2X4SYPNo.2 REACTIONS (lb/size) 15=1611/0-0-0, 10=138&0-B-0 Max Horz 15=81(load case 5) Max Upliftl5=-480(load case 5), 10=-074(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=20781493, 2-3=2363/613, 3■1=2180/597, 4-5=2639/836, 5.6=19301640, 6.7-2089/637, 7-8=1999/628, 8-9=1610/438 BOT CHORD 1-15=-491/2070, 14-15=-560/2070,13-14=365/1750, 12-13=557/2383,11-12--557/2383, 10-11=-479/1689, 9-10=-479H689 WEBS 3.14=205/181, 4-14=131/443, 4-13=462/1325, 5-13=985/422, 5.11=527/161, 6-11=20/370, 7-11=-43/246, 2-15=-804/317, 8-10=-1076/457 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of wfthstan ding 480 lb uplift at joint 15 and 474 lb uplift atjoint 10. - - - LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Irxxease=1.25 Uniform Loads (plf) Vert: 1-4=-70, 4-5=70, 5-6=-70, 6-9=-70, 1-15=20, 14-15=-65, 9-14=20 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, r� Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION j3�4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate � plates 0 - 1/16" from outside a. edge of truss. o *This symbol indicates the required direction of slots in connector plates, * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension Is the length parallel to slots, LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output, Use T, I or Eliminator bracing If indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section Indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1; Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A c� e TEE-LOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or .Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII I. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and 0 embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or puriins provided at spacing shown on design. 13, Bottom chords require lateral bracing at 10 ft, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Homes. Model 1577 A BOS SPECIAL ReferencetionalUniversal F�roduct Inc. E359, Ft. Pierce, R. 34946, James L Staaf Dec 1 2005 MTek Industries, Inc. Thu Feb 01 08: 07 Page 1 5-11-14 11-9-0 16-0-0 23-0-0 26-7-14 30-0-0 , 5-11-14 5-9-2 49-0 6-6-0 3-7-14 34-2 Scale = 1:51. 5x5 = 4 5.00 12 x9 = 5x7 = 4x6 � 6 3 nWW2 s >14 7 3 WS 3x711 2 B 1 9 I$ 3x5 15 14 13 12 11 10 5x8 \\ 3x6 = 4x6 = 3x8 = ,1-0-0, 7-11-2 16-6-0 23-0-0 29-0-0 $0-0-0 1-0-0 6-11-2 5-0-14 6-6-0 6-U-0 1-0-0 Plate Offsets 3:a1-6 a2-0a:a2-4 a2-8 5:a5-0 03-4 , fi:o-0-0 a2-4 8:03-8 aa1 9:03-0 a1-8 15:05-1 a2-0 LOADING (psi) SPACING 24).0 CSI DEFL in (loc) Udefl L/d PLATES GRIP TOLL 20.0 Plates Increase 1.25 TC 0.74 Vert(LL) -0.1612-14 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.5412-14_ >609 180 BCLL 10.0 Rep Stress Incr NO WB 0.78 Horz(TL) 0.10 10 Na Na __ BCDL 10:0 Code FBC2004/TPI2002 (Matrbc) Weight 1481b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 •Except• TOP CHORD Structural wood sheathing directly applied or 3-2-8 ac pudins. T4 2 X 4 SYP SS BOT CHORD Rigid ceiling tiredly applied or 7-4-11 oc bracing. BOT CHORD 2 X 4 SYP No.2 WEBS 2X4SYP No.2 REACTIONS (Ib/sae) 15=135010-8-0, 10=1350/0-" Max Horz 15=-81(load case 6) Max Uplift15=411(load case 5),10=-465(load case 6) FORCES (lb) -Maximum Compression/Maximum Tension TOP CHORD 1-2=244/38, 2-3=331/98, 3-0=2041J548, 45=-3220/1011, 5-6=1954/640, 6-7=2101/640, 7-8=1666/516, 8-9=1247/334 BOTCHORD 1-15=39/249, 1415=511/1900, 13-14=333/1613,12-13=333/1613, 11-12=725/2863, 1a11=366/1333, 9-10=368/1333 WEBS 3-14=193/178, 414=108Y390, 412--622/1854, 5-12=1148/485, 5.11=1003/240, 6-11=231370, 7-11=168/639, 2-15=316/181, 8-10=1160/448, 3-15=1881/493 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02;130mph (3-second gust); tr-20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed fora 10.0 psf bottom chord live load nonconcun'ent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 411 lb uplift at:joiM 15 and 465 lb uplift at joint 10. LOAD CASE(S) Standard WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MTek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite 4300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delive O 0 Job TNss Thus Type Qty :JyZntex ryRnfaty Infn—finn —Inhin f—rn Tri t�q Pic&� Insfifi itp 583 D'Onofron Drive. Madison, WI 53719, MnTel , Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat, 0 O *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but EV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1; National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBEREDAETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all pC other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14, Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Ply Centex Homes, Model 1577 A X06-019 BO6 SPECIAL 10ty 1 1 Job Reference o tional Universal F roduct, Inc. E359, Ft Pierce, Fl. 34946, James L Shoat 6.300 s Dec MTek Industries, Inc. Thu Feb 01 G8:&W9LI2W7 Page 1 4 )-11 7-9-6 11-9-0 15-8-10 , 18-6-0 L 22-2-0 , 25-M 304)-0 , 4-0-11 3-8-11 3-11-10 3-11-10 2-9-6 3-8-0 2-10-0 5-0-0 Scale =1:51. 4x6 = 5 5.00 +2 4 6 W 1 4x6 = 5x7 = 7 8 18 9 3 Ta W 5 WIV 2 10 3x5 ir 17 16 15 14 19 13 12 3x6 11 3x8 = 5x12 = 5x8 = US 11 0-0-0 0-0-0 0-M 0-0-0i 7-9-6 15-1-8 18-6-0 22-2-0 25-M 29-0-0 $0-0-0 1-M 6-9-6 7-4-2 3-4-8 3-8-0 2-10-0 4-0-0 1-" Plate Offsets 1:0-3-0 0-1-8 :05.4 0-2-1 120-2.8 0.1-4 15:0-5-0 0-3-017:0-1-11 0-1.4 LOADING (psf) SPACING 2-0-0 CS! DEFL in (Ioc) Udeft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.52 Vert(LL) -0.08 15 16 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.59 Vert(TL) -0.28 15-16 >883 180 BCLL 10.0 Rep Stress Inca NO WB 0.47 Horz(TL) 0.03 14 n/a n/a BCDL 10.0 Code FBC2004IrP12DO2 (Matrix) Weight 147lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 'Except! TOP CHORD Structural wood sheathing directly applied or 5-3.2 oc pudins. Ti 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 6-M oc bracing. BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 14=1893/0-8.0, 12=162/0-3.8, 17--A7/0-8.0 Max Horz 17=81(load case 5) Max Uplift114=-82D(load case 6), 12=261(load case 6), 17=314(load case 5) Max Gravl4=1893(load case 1), 12=223(load case 8),17=947(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=942J2D4, 2-3=-1198/329, 34=1190/301, 4-5=1230/394, 5-6=932QN, 6-7=916/213, 7-8=344/1045, 8-18=344/1046, 9-18=344/1045, 9.10=0/250, 10-11=0/215 BOT CHORD 1-17=224/990, 16-17=305/990, 15-16=115/742, 14-15=0/411, 14-19=166/0, 13-19=166/0, 12-13=175/0, 11-12=175/0 WEBS 3-16=0/140, 4-16=356/207, 5-16=219/577, 5-15=-60/214, 6-15=247/155, 7-15=151/507, 7-14=16831488, 8-14=288/167, 9-14=1099/639, 9-13=-199/242, 10-12=203/158,2-17=-743/296 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0_psf bottom chord live load nonconcurrent with any other live loads. - 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 820 lb uplift at joint 14, 261 lb uplift at joint 12 and 314 lb uplift at joint 17. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 86 Ib down and 51 lb up at 22-10-15, and 264 lb dawn and 147 lb up at 25.0-0 on top chord, and 291b down and 25 lb up at 22-10-15. and 105 lb down and 82 lb up at 24-10-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-5=70, 5.7=-70, 7-9=70, 9-11=-70, 1-11=-20 Concentrated Loads (lb) Vert: 9=184(B) 13=52(B) 18=-46(B) 19=-20(B) A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MTek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite 0300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component O Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. 1 I Symbols PLATE LOCATION AND ORIENTATION 13/, *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. in cc O U o_ O H Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. TEE - LOP KI 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type qly Ply Centex Homes, Model 1577 A XO6 019 B 77 HIP 1 1 Job Reference tional Universal �Produet Inc. E359, Ft Pierce, Ft.34948, James L Sfwaf 6.300 s Dec 1 2005 MTek Industries. Inc. Thu Feb 01 08:03:42 Age 1 5-0-10 11-M 12-6-0 18-5-6 22-" 5-0-10 5-11.6 1-6-0 5-11-6 4-0-10 Scale =1:37. 5x5 = 5x5 = 4 5 5.00 12 W 1 3 6 7 2 W 2 8 _1 d 3x5 4x6 0 11 10 9 6a II 3x6 It 3x4 = 3x6 = 3x4 = 0-0-0 0-0-0 1-M , 8-5-11 15-0-5 22-6-0 , 1-0-0 7-5-11 6-0-11 7-5-11 Plate Offsets 1:0-M 0-1$ 4 0-2-4 0-2.8 8:0-5-4 E e , 12:0-1-110.1-0 LOADING (psi) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.76 Vert(LL) -0.14 9-11 >999 360 MT20 244/190 TCDL-- 15.0 Lumber Increase 1.25 BC 0.82 Vert(TL) -0.40 9-11 >640 180 BCLL 10.0 Rep Stress Ina NO WB 0.12 Horz(TL) 0.07 8 rda n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight 103lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS'Except' TOP CHORD Structural wood sheathing directly applied or 3S1 oc pudins. T2 2 X 6 SYP SS, T3 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 8.6-13 or bracing. BOT CHORD 2 X 4 SYP SS WEBS 2 X 4 SYP No.2 SLIDER Right 2 X 6 SYP SS 2-1-14 REACTIONS (lb/size) 8=1423/0-", 12--1614/0S-0 Max Horz 12=76(load case 5) Max Uplift8=-390(load case 6), 12=-495(load case 5) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=1897/478, 2-3=2206/623, 3.4=2066/538, 4-5=1665/508, 5-6=2204/585, 6-7=2371/697, 7-8=24281684 BOT CHORD 1-12=492/1916, 11-12=-567/1916, 10-11=369/1665, 9-10=369/1665, 8-9=570/2135 WEBS 3-11=132/171, 4-11=104/479, 5-9=167/662, 6-9=260/215, 2-12=-873/337 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02;130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Dpst Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 390 lb uplift at joint 8 and 495 lb uplift atjoint 12. LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 14=70, 4-5=70, 5-8=-70, 1-8=-65 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. We Symbols PLATE LOCATION AND ORIENTATION 1'/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside o_ edge of truss. *This symbol indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e,g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. o- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. * Plate location details available in MiTek 20/20 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice p fi' 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text In the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design, if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1; Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Mitek® Connected Wood Trusses. " Job Truss Thus Type Oty Ply Centex Homes, Model 1577 A XO6-019 BOB HIP 1 1 Job Reference a tional Universal �"Product, Inc. E359, Ft Pierce, R. 34946. James L Shoaf 6.300 s Dec 1 2005 tr�Tek Industries, Inc. Thu Feb 01 08:03:43 ge 1 4-5-2 9-0-0 14-6-0 22-6-0 4-5-2 4-6-14 "_0 8-0-0 Scale= 1:37. 5x8 = 5x5 = 4 5 5.00 12 1.5x4 6 Wi 3 3x6 II 3 2 7 I6& Bi 3x5 = 4x6 US a km 10 9 9 5x7 II 3x6 = 1-4-0 0-M 9-M 14-6-0 22-6-0 , 1-M 7-8-0 5-6-0 8-0-0 04-0 Plate Offsets 1:0-1-6 0-020-1-11 0.0-1 4:05-4 0-2-45:0-2-80-2-1 :0-4-8.0-2-1 LOADING (psf) SPACING 2-0.0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.97 Vert(LL) -0.08 7-8 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.76 Vert(TL) -0.25 7-8 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.07 Horz(TL) 0.05 7 n/a n/a BCDL 10.0 Code FBC2004/TPl2002 (Matra) Weight 107lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 SLIDER Right 2 X 6 SYP SS 4-4-11 REACTIONS (lb(s¢e) 7=949/0.8-0, 11=1076/0-B-0 Max Horz 11=-62(load case 6) Max Up!Vft 248(load case 6), 11=-336(load case 5) FORCES (lb) - Maximum CompressiorJMaximum Tension TOP CHORD 1-2=1202/281, 2-3=1471/400, 3-4=13931388, 4-5=1335/414, 5-6=1443/409, 6-7=1561/392 BOT CHORD 1-11=-301/1244, 10.11=345/1244, 9-10=266/1262, 8-9=266/1262, 7-8=292/1331 WEBS 3.10=0/138, 4-10=0/194, 4-8=114/197, 5.8=0/247, 2-11=776/327 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2pst,, BCDL=3.Opst,, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Al plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 248lb uplift atjoint 7 and 336lb uplift atjoint 11. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates.to both sides of truss 1. Additional stability bracing for truss system, e.g, diagonal and securely seat. or X-bracing, is always required. See BCSI1. 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack -� C7-2 C2-3 materials on inadequately braced trusses. WEBS ,?� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all * For, 4 x 2 orientation, locate �,� �,�' 3 O other interested parties. Pic0 - /ie" from outside truss. O U 4. Cut members to bear tightly against each other. edge of a. 5. Place plates on each face of truss at each joint and C7-e Cea cs-s OR embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 b. Design assumes trusses will be suitably'protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4. X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements, LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek@ DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate i © 2004 Miteko Connected Wood Trusses. Job Truss Truss Type Oty Ply Homes, Model 1577 A X06-019 B09 HIP 1 1 JCentex Job Reference o tlonal Universal 60g* Product, Inc. E359, FL Pierce, A. 34946, James L Shoal 8.300 s Dec 1 2005 MTek Industries, Inc. Thu Feb 01 0 : . 2007 Page 1 , 3-4-2 7-0-0 11-9-0 16-6-0 , 20-1-14 , 2M-0 � 3-4-2 3-7-14 4-9-0 4-9-0 3-7-14 3-4-2 Scale =1:39. 1.5x4 II 4 13 14 5 15 16 6 5.00 72 .5x4 3 IV, Y1 7 CA 2 8 t-417. 1 9 3x4 — 5x10 r 3x4 = 12 17 18 11 19 20 10 5x10 0 3x4 = 3x4 = 0-0-0 0-" ,1-0-01 7-0-0 11-9-0 16-" 22-6-0 ,23-6-0, 1-0-0 6-0-0 4-9-0 4-9-0 6-0-0 1-" Plate Offsets 1:03-z 0-2.8 4:05-4 0-2-4 6:0-5-4 0-24 9:0-3-2 0.2.8 11:04-0 0-3-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (lox) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.48 Vert(LL) 0.15 11 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.72 Vert(M) -0.40 11-12 >688 180 BCLL 10.0 Rep Stress Ina NO WB 0.16 Haz(TL) 0.14 9 n/a Na BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 119 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-10-2 or pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-103 oc bracing. WEBS 2 X 4 SYP No.2 SLIDER Left 2 X 6 SYP SS 1-9.7, Right 2 X 6 SYP SS 1-9-7 REACTIONS (Ih/s'¢e) 1=1759/0-8.0, 9=1759/0-8-0 Max Horz 1=49(load case 6) Max Uplift1=597(load case 5), 9=587(load case 6) FORCES (lb) - Maximum Compress'ioWaximum Tension TOP CHORD 1-2=3723/1292, 2-3=3664/1295, 3-4=3666/1269, 4-13=-4034/1464, 13-14=4034/1463, 5-14= 4034/1463, 5.15=-0034/1463, 15.16=-0034/1463, 6-16-4034/1464, 6-7=3666/1278, 7-8=3664/1273, 8-9=3723/1271 BOT CHORD 1-12=1176/3321, 12-17=1124/3384,17-18=1124/3384, 11-18=1124/3384, 11-19=1114MW, 19-20=1114/3384, 10-20=1114/3384, 9-10=1108/3321 WEBS 3-12=33/219, 4-12= 49/484, 4-11=309/853, 5-11=-617/344, 6.11=298/831, 6.10--W/484, 7-10=35/225 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02;130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 5x8 MT20 unless otherwise indicated.- 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 597lb uplift at joint land 587lb uplift at joint 9. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)187lb down and 131 lb up at 7-0-0,104lb down and 75 Ib up at 9-0-12, 104 lb down and 75 lb up at 11-0-12, 104 lb dawn and 75 lb up at 12-5-4, and 104 Ib down and 75 Ib up at 14-5-4, and 227 lb down and 131 lb up at 16-6-0 on top chord, and 248 lb down and 66 lb up at 740-0, 64 lb down at 9-0-12. 64 lb down at 11-0-12, 64 lb down at 12-5-4, and 64 lb down at 14-54, and 248 lb down and 66 lb up at 16.54 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumberincrease=1.25, Platelncrease=1.25 Uniform Loads (plf) Vert: 1-4=70, 4-6=70, 6-9=70,1-9=20 Concentrated Loads (lb) Vert: 4=187(8) 6=187(B)12=248(B)10=248(B)13=104(B)14=104(B)15=104(B)16=-104(B)17=44(B)18=44(B)19=44(B) 20=-44(B) A WARNING - VertJy design parameters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-1hd1 * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the _ required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1; National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSII ; Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A ou"s-ml AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O v 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10, Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1577 A XOB-019 CO, COMMON 1 1 Job Reference tional Universal ForesljbpLblct. Inc. E359, FL Pierce, Fl. 34946, James L Shoaf 6.3W s Dec 1 ZOOS MTek Industries. Inc. Thu Feb 01 08 2007 Page 1. 7-" 14-0-0 , , 7-0-0 7-0-0 Scale =1:22. 46 = 2 4.00 12 W1 1 1 1 3 5x7 11 4 5x7 II 0-0-0 0-" 1 0 0 1 i1 r8 7-" 12-10-8 1 M-014-0-0 , , 1-0-0 0-1-8 5-10-8 5-10-8 0-1-8 1-0-0 Plate Offsets 1:0-0 81-2-41:0-3-140.0-2 2.0-3-00.2A 3:03140.0-2 3:0.0-81-2-4 LOADING (psf) SPACING 2-" CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.61 VerKLL) 0.14 1-4 >999 360 MT20 244/19D TCDL 15.0 Lumber Increase 1.25 . BC 0.80 VerWM) -0.18 3-4 >918 180 BCLL 10.0 Rep Stress Ina YES WB 0.06 Horz(TL) 0.03 3 Na rJa BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 49 lb LUMBER BRACING - TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-2-3 oc puriins. BOT CHORD 2 X 4 SYP N0.2 BOT CHORD Rigid calling directly applied or 7-1-0 oc bracing. WEBS 2 X 4 SYP Not WEDGE Left 2 X 4 SYP No.2, Right: 2 X 4 SYP No.2 REACTIONS (INsize) 1=619/0-3-0, 3=619/0-3-0 Max Horz 1=39(load case 6) Max UPlift1=-428(load case 3), 3=-428(load case 4) FORCES (lb) - Maximum CompressioniMaximum Tension TOP CHORD 1-2=1239/798, 2-3=1239f798 BOT CHORD 1-4=715/1108, 3.4=715/1108 WEBS 2-4=252/331 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02: 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Op6f; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3)'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 428lb uplift at joint 1 and 428 lb uplift atjoint 3. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property �3/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. � or X-bracing, is always required, See BCSI1. 0-1/01 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z c materials on inadequately braced trusses. �� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all For 4 x 2 orientation, locate o�,Z37 other interested parties. plates 0 - 1 /16" from outside 0 �,� U 4. Cut members to bear tightly against each other. edge of truss. O I— 5. Place plates on each face of truss at each joint and c7-8 cs-a c5-6 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. * Plate location details available in MiTek 20/20 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with'fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General res onsibili practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated b symbol shown and/or y y BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section Indicates joint approval of a professional engineer. number where bearings occur. 16, Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek® DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses, Job Thus Truss Type Qty Ply Centex Homes, Model 1577 A X06Job CO2 HIP 1 1 Job Reference tonal Universal Fores et, Inc. E359, Ft. Pierce, Fl. 34946. James L Shoaf 6.300 s Dee 1 2005 M1Tek Industries, Inc. Thu Fab 01 8: :44 2007 Page 1 5-0-0 9-M , 14-0-0 , , 5-M 4-0-0 5-0-0 Scale =123.1 5x8 = 2 7 3 4.00 12 W2 w2 1 HW1 HW1 4 rF 81 5x8 11 6x10 II 6x10 II 4x4 = 6 8 5 4x4 II 5x8 11 0-M 0-M 14-0-0 1-0-0 1,1r8 5-0-0 9-0-0 12-10-8 1M-0 , 1-0-0 0-1-8 3-10-8 4-0-0 3-10-8 0-1-8 1-0 0 Plate Offsets 1:0-0-12 2-0-2 1:0-0-01-3-1 1:0.1-14 E 3:05d 0-2A4:0-1-14 E 4:0-0.01-3-1 4:0.0-12 2.0-2 LOADING (psi) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates increase 1.25 TC 0.75 Vert(LL) 0.15 5.6 >999 360 MT20 2441190 .TCDL 15.0 --Lumber Increase 1.25 BC 0.94 Vert(TL) -0.21 5-0 >780 180 BCLL 10.0 Rep Stress [nor NO WB 0-09 Horz(TL) 0.06 4 rda n/a BCDL 10.0 Code FBC2004/TPI2002 (Matra) Weight 64lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-7-8 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 4-5-16 oc bracing. WEBS 2 X 4 SYP No.2 WEDGE Left: 2 X 8 SYP SS, Right: 2 X 8 SYP SS REACTIONS (lb/s¢e) 1=1074/0-3.0, 4=1075/0.3-0 Max Horz 1=28(load case 6) Max Upliftl=-805(load case 3), 4=-810(load case 4) FORCES (lb) - Maximum CompressiomMaximum Tension TOP CHORD 1-2=-2729/2026, 2-7=2562/1980, 3-7=2562/1980, 3.4=2732(2041 BOT CHORD 1.6=1892/2529, 6-8=1920/2565, 5-8=1920/2565, 4-5-1886/2532 WEBS 2-6=-409/466, 3-0=102/130, 3-5=392/467 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4)'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 805lb uplift at joint 1 and 810 lb uplift at joint 4. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)160 lb down and 115 lb up at 6-0-0, and 98 lb down and 81 lb up at 7-0-12, and 120 lb down and 115 lb up at 9-0-0 on top chord, and 272 lb down and 231 lb up at 5-0-0, and 56 lb down and 41 lb up at 7-0-12, and 272lb down and 231 lb up at 8-11-4 on bottom chord. The designiseledion of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pif) Vert: 1-2=-70, 2-3=-70, 3-0= 70, 14=-20 Concentrated Loads (lb) Vert 2=120(B) 3=120(B) 6=272(B) 5=272(B) 7=98(B) 8=28(B) A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack 07-2 C2-3 materials on inadequately braced trusses. WEBS C3� 4 3. Provide copies of this truss design to the building cc designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate �,� ��� 3 other interested parties. Plates 0 - /ie" from outside O a_ U 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and C7-e Csa C5-6 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates, the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice p tY 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. If indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior EV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Miteko Connected Wood Trusses, V\/\d VW`q Job Truss Type Oty Pty Homes, Model 1577 A rruss X06-019 J1 MONO TRUSS 6 17. Reference o clonal Universal Forest Product Inc. E359, FL Pierce. Fl. 34946, James L. Shoaf 2 6.3tJ#Jeac 12005 Work Industries, Inc. Thu Feb 01 08:03:" 2007 Page 1 1-0-0 14)-0 Scale = t:a. 5.00 12 'XSIMPSON SAT 1 F r, 3x4 - 3 0-0-10 0-U-0 1-M 1-0-0 Plate Offsets X 1:0.0-0 0-0-0 LOADING (psf) SPACING 2.0.0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) -0.00 1 n1r 180 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) -0.00 1 Nr 90 BCLL 10.0 Rep Stress Ina YES WB 0.00 Haz(TL) 0.00 Na rJa BCDL 10.0 Code FBC20041TPI2002 (Matrix) Weight: 3 lb LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or SAW oo tracing. REACTIONS (lb/size) 3=10/Mechanical, 2=791Mechanical Max Horz3=98(load case 1), 2-98(load rase 1) Max Upltft3=14(load case 3), 2=-Wload case 5) Max Grav3=20goad case 2), 2=79(load case 1) FORCES (lb) - Maximum CompressxxdMaximum Tension TOP CHORD 1-2=$0/11g BOT CHORD 1-3=98/82 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft, TCDL=4.2psf; BCDL=3.0psf: Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This buss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3 and 50 lb uplift atjoint 2. 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard A WARNING - VerWy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Wei Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. 1. Additional stability bracing for truss system, e.g. diagonal Apply plates to both sides of truss or X-bracing, is always required. See BCSI1. and securely seat. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-z caa materials on inadequately braced trusses. WEBS ¢,� 4 3. Provide copies of this truss design to the building Cc designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate ? �,� ��1 3 O other interested parties, plates 0 - 1/16" from outside a. �°� 19 U 4. Cut members to bear tightly against each other. edge of truss. 11 5. Place plates on each face of truss at each joint and c7-e csa ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates, the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MITek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber Is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots, Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots, CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements, LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section Indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Miteke Connected Wood Trusses. Job Truss Type Oty Pty n nres, Model 1577 A j(06-019 CJ1 P MONO TRUSS 4 1 Job Reference (Options incTruss Universal Forest Product. E359, Ft. Pierce, Fl. 34946, James L Shoat 6.300 ®!bkq 12005 MiTek industries, Inc. Thu Feb 01 08:03:45 2007 Page 1 1-0-0 1-0-0 4.00 FIT Scale =1:4. , SIMPSON T1 MTS16 4x4 = 3 0-3-12 0-0-0 1-0-0 1-M LOADING (psf) SPACING 2-M CS! DEFL in (loc) Wall Lfd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.04 Varga) -0.00 1 Nr 180 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(M) -0.00 1 n/r 90 BCLL 10.0 Rep Stress Ina YES WB 0.00 Hwz(TL) 0.00 Na n1a . BCDL 10.0 Code FBC2004f1'PI2002 (Matrix) ) Weight 3 lb - LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-M oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceding directly applied or 6-0.0 oc bracing. REACTIONS (Ibfsize) 3=10/Mechanical, 2=79/Mechanical Max Horz3=123(load case 1), 2=123(load case 1) Max Upfift3=14(load case 3), 2=-50(load case 3) Max Grav3=20(load case 2), 2=79(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=96/140 BOT CHORD 13=123197 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=201(; TCDL=42psF BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with arry other live loads. 3) Refer to 91fder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 14lb uplift at joint 3 and 50lb upltft at joint 2. 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard A WARNING - Verljg design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MlTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPIi Quality Criteria, DSB-89 and BCSIi Building Component iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M Symbols PLATE LOCATION AND ORIENTATION -01 14-�3/4 * Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 -1/16 0 O * For 4 x 2 orientation, locate plates 0 -1/0 from outside edge of truss. R *This symbol Indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or .Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available In Welk 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of .truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension Is the length parallel 10. Plate type, size, orientation and location dimensions to slots, CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11, Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12, Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. If Indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. t�w (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section Indicates joint lip approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards, ANSI/TPI1; National Design Speciflcatlon for Metal Plate Connected Wood Truss Construction. M iTek® DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, © 2004 Mitek® Installing & Bracing of Metal Plate Connected Wood Trusses. ' Job Thus Truss Type Qty Pfy Homes, Model 1577 A XO6-019 CA U MONO TRUSS 10 1 Job Reference o tional Universal Forest Product Inc. E359, Ft Pierce, Ft 34946, James L. Shoal 2 6.3tJ@- ec 12005 MTek Industries, Inc. Thu Feb 01 08:03:45 2007 Page 1 1-0-0 1-0-0 5.00 12 Stale =1 A 1 T1 SIMPSON MTS16 3A = 3 0-4-10 0-0-0 1-0-0 LOADING (psf) SPACING 2-" CSI DEFL in (loc) Well Lid PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) -0.00 1 nir 180 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Verl(TL) -0.00 1 nir 90 BCLL 10.0 Rep Stress Ina YES WB 0.00 Hw4M) 0.00 nla rile BCDL 10.0 Code FBC20041TPI2002 (Matra) ' Weight: 3lb LUMBER BRACING TOP CHORD 2 X 4 SYP No'2 TOP CHORD Structural wood sheathing directly applied or 1-" oo purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (Ibls¢e) 3=10A4echanical, 2=79/Mechanical Max Horz3=99(load case 1), 2-J9(load case 1) Max UpIM--14(load case 3), 2=50(load case 5) Max Grav3=20(load case 2), 2=79(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2--801120 BOT CHORD 1-3=99182 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20R; TCDL=4.2pst BCDL=3.Opst Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girders) for truss to truss connections. 4) Provide mechanical: connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3 and 50lb uplift at joint 2. 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard A WARNING - Veri, jy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MTek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component O Safety Information available from Truss Plate Institute, 683 D'Onofrio Drive, Madison, WI 53719. ITe Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 O U EL O R Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all pc other interested parties. O U 4. Cut members to bear tightly against each other. o- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job Truss Truss Type Oty Ply Centex Homes, Model 1577 A X06-019 CJ3 MONO TRUSS 4 1 S" Job Reference tional Universal Forest Product, Inc. E359, FL Pierce, R. 34946, James L Shoaf 0-0-0 6.300 s Dec 1 2005 hiTek Industries, Inc. Thu Feb 01 08:03:45 2007 Page 1 3-0-0 3 3-0-0 Scale: 1.5=1 5.00 FIT 34 II 2 T1 1 1 B1 3x4 ->< 5 4m 0 -0 1-0-0 , 14-0 3-0-0 i 1-M 04-0 1-" Plate Offsets X 2:0-1-11 0-0-0 LOADING (psf) SPACING 2-0.0 CSI OEFL in (loc) Well Lid PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) 0.00 5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) 0.00 4-5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0-02 Horz(TL) -0.00 3 n/a n/a BCOL 10.0 Code FBC2004/TP12002 (Matra) Weight 10lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3.0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEBS 2X4SYPN0.2 REACTIONS (lb(size) 3=281Mechanical, 4=-6/Mechanical, 5=24210-0-0 Max Horz5=56(load case 5) Max Upldt3=22(load case 5), "-load case 1), 5=126(load case 5) Max Grav3=28(load case 1), 4=12(load case 5), 5=242(load case 1) FORCES (lb) -Maximum CompressiordMaximum Tension TOP CHORD 1-2=55/33, 2-3=32/6 BOT CHORD 1-5=0/56, 4-5=0/0 WEBS 2-5=165/95 NOTES 1) Wind: ASCE 7-02;130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed: Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 22 lb uplift at joint 3, 6 lb uplift at joint 4 and 126 lb uplift atjoint 5. LOAD CASE(S) Standard - A WARNING - Verlfg design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, W153719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property -01 14-j3/4 * Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g, diagonal and securely seat. or X-bracing, is always required, See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z materials on inadequately braced trusses. �34 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all For 4 x 2 orientation, locate Z23 o � 4, other interested parties. plates 0 - 1/16" from outside 4, Cut members to bear tightly against each other. edge of truss. °5. Place plates on each face of truss at each joint and c7-ece-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated byANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication, software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 It. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior Lip reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate B © 2004 MiteV Connected Wood Trusses. ��� Job Truss Truss Type Qty Ply Centex Homes, Model 1577 A X08-019 CJ3P MONO TRUSS 2 1 10a Job Reference (optional) Universal Forest Product Inc. E359, FL Pierce, Ff. 34948, James L Shoal �-0 8.300 a Dec 1 2005 MTek Industries, Inc. Thu Feb 01 08:0345 2007 Page 1 3-0-0 3 3-0-0 Scale:l.5'=1 6.00 3r5 II 2 T7 1 81 3c4 = 5 4 IMM Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property �3/4 * Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required, See BCSI l , 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z cz-a materials on inadequately braced trusses. WEBS 4 3. Provide copies of this truss design to the building cc designer, erection supervisor, property owner and all *For4 x 2 orientation, locate 9 ' 3 CC O other interested parties. plates 0 - /ia" from outside �a6 U 4. Cut members to bear tightly against each other. edge of truss. OR a. 5. Place plates on each face of truss at each joint and c7-e csa cs-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4. perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design, if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Welke Connected Wood Trusses, R Truss Type Oty Homes, Model 1577 AOM-02 JobJob JTruss CJ3PA MONO TRUSS JP�IyaQentex 4 b Reference(optional) Universal Forest Product Inc. E359, FL Pierce, Fl. 34946. James L. Shoaf 0-M 6.300 s Dec 12005 6ATek Industries, Inc. Thu Feb 01 08:03:45 2007 Page 1 3-0-0 2 3-0-0 Scale= 1:7. 4.00 12 T1 1 1 B1 4x4 = 4x6 II 3 OM-02 0 3-0-0 , 1-M 0-1-8 1-10-8 Plate Offsets 1:0-2-14 E 1:0-1.4 1-2-1 LOADING (psf) SPACING 2-" CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.13 Vert(LL) 0.01 1-3 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.08 Vert(TL) -0.01 1-3 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 — Ho z(TL) -0.00 2 Na nia BCDL 10.0 Code FBC2004rrP12002 (Matrix) Weight: 11 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-00 oc puriins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEDGE Left: 2 X 4 SYP No.2 REACTIONS (Ib/size) 2=98/Mechanical, 3=281Mechanical, 1=12710.3-0 Max Horz 1=45(load case 3) Max Uplift2=-59(load case 3), 3=-41(load case 3), 1=4wload case 3) Max Grav2=98(load case 1), 3=56(load case 2), 1=127(load case 1) FORCES (Ib) - Maximum CompressiordMaximum Tension TOP CHORD 1-2=27/27 BOT CHORD 1.3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20fh, TCDL=4.2psF, BCDL=3.OpsF Category II; Eup B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load non concurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 59 lb uplift at joint 2, 41 lb uplift at joint 3 and 84 lb uplift at joint 1. LOAD CASE(S) Standard A WARNING - Veryj design parameters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property j'/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1, 0-1/01 2 3 TOP CHORDS 2, Never exceed the design loading shown and never stack c1-2 c2-8 materials on inadequately braced trusses. WEBS °3� 4 3. Provide copies of this truss design to the building O designer, erection supervisor, property owner and all For 4 x 2 orientation, locate 6 X � �� .��' 6 � O other interested parties. p pla0 - 1/16" from outside o gab U 4. Cut members to bear tightly against each other. edge of truss. o_ 5. Place plates on each face of truss at each joint and c7-8 csa ce-6 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication, software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design, if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, • Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Job Truss Truss Type Qty Ply Centex Homes, Model 1577 A X06-019 CJ3U MONO TRUSS 7 1 �� Job Reference tkxwl Universal Forest Product, Inc. E359, FL Pierce, R. 34946, James L Stxraf 0-0,.p 6.300 s Dec 1 ZOOS fvtiTek Industries. Inc. Thu Feb 01 08:03:46: 2007 Page 1 3-0-0 3 3-0-0 Scale:l.S=1 5.00 12 2 T1 1 1 61 14 = 5 4 1-0-0 1-4-0 3-0-0 , 1-0-0 04-0 Plate offsets 5:0-1-11 0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 125 TIC 0.09 Vert(LL) 0.00 5 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) 0.00 45 >999 180_ BCLL 10.0 Rep Stress Inca YES WB 0.02 Haz(TL) -0.00 3 Na Na BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight 10 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0.0 oc purfins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (Ib/s"¢e) 3=28lMecttanipl, 4=6/Mechanical, 5=242(0-8.0 Max Horz5=56(load case 5) Max Uplift3=22(load case 5), "load case 1), 5=126(load case 5) Max Grav3=28(load case 1), 4=12(load case 5), 5=242(load case 1) FORCES (lb) -Maximum Compression/Maximum Tension TOP CHORD 1-2=55/33, 2-3=32/6 BOT CHORD 1-5=0/56, 45=0/0 WEBS 2-5=165/95 NOTES 1) Wind: ASCE 7-02;130mph (3-second gust); f1=20ft; TCDL=4.2psf; BCDL=3.Opsh, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed fora 10.0 psf bottom chord live load norxbnament with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 22 lb uplift at joint 3, 6 lb uplift at joint 4 and 126 lb uplift at joint 5. LOAD CASE(S) Standard - A WARNING - Verljy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with Mfiek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer -not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/q *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but EV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Cc O U Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 0 TEE-LOK O U IL O R AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e,g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is instalied,'uniess otherwise noted, 14. Connections not shown are the responsibility of others. 15, Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Thus Truss Type Oty Ply Centex Homes, Model 1577 A X06-019 CJ3UA MONO TRUSS 71 Job Reference o clonal Universal Forest Product, Inc. E359, Ft Pierce, Fl. 34946, James L Shoaf 0-" 6.300 s Dec 12005 MTek Industries. Inc. Thu Feb 01 08:03:46 2007 Page 1 3-0-0 3 3-0-0 Scale:l.5-=1 2 5.00 F12 SIMPSON T, w, MTS16 B, 3A - 5 4 Ulm 0 0 M-0 3-M , , 2-M 04-0 LOADING (psf) SPACING 2.0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.24 VerKLL) 0.00 5 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.22 Vert(TL) 0.00 5 >999 180 BCLL 10.0 Rep Stresslncr. YES WB D.04 Horz(TL) -0.03 3 rJa Na BCDL 10.0 Code FBC20041TPI2002 (Matrix) Weight 11Ib LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-" oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. WEBS 2X4SYP No2 REACTIONS (lb/sae) 3=193/Mechanical, 4=185/Mechanical, 5=643/0-8-0 Max Horz5=56(load case 5) Max Uplift3=193(load case 1), 4=185(load case 1), 5=398(load case 5) Max Grav3=107(load case 5), 4=120(load case 5), 5=643(load case 1) FORCES (lb) - Maximum Compnession/Maximum Tension TOP CHORD 1-2=52/54, 2-3=90/41 BOT CHORD 1-5=0/56, 4-5=0/0 WEBS 2-5=372/217 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20fl; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 193 lb uplift at joint 3, 185 lb uplift at joint 4 and 398 lb uplift at joint 5. LOAD CASE(S) Standard - WWARNING - Ver!,fy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/, *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. * Plate location details available in MiTek 20/20 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice P fi' 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified, by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior EV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M ITeko DSB-89: Design Standard for Bracing. BCSII : Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Mitek® Connected Wood Trusses. " A X06-019 CJS ]MONO TRUSS 4 1 M'm Job Reference o tlonal Universal Forest Product, Inc. E359, Ft Pierce, ��jr Fl. 34946, Jam,b,oaf 6.300 s Dec 1 2005 tytiTek Industries. Inc. Thu Feb 01 08:03:46 2007 Page 1 5-0 O Job . Truss Tniss Type Oty Ply Centex Homes, Model. -0 -0 -0 Male Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property j3/q *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. c1-2 c2-3 WEBS c3� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate 6 �,� 3 ��' m other interested parties, plates 0 - 1 /16" from outside O U 4. Cut members to bear tightly against each other. edge of truss, °- 5. 'Place plates on each face of truss at each joint and c7-e csa ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. — required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction, M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, 119 El O Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Job Thus Taus Type llty, Pry Centex Homes, Model 1577 A XO6-019 CJSu MONO TRUSS 4 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft Pierce, Fl. 34946. James.b_Jnoaf 6.300 s Dec 12005 MiTek Industries, Inc. Thu Feb 01 08:03:46 2007 Page 1 5-0-0 3 5-0-0 Scale: 1'=1 5.00 12 T1 2 81 3x4 = 4 0-0-0 34 11 1-M 1-4-0 , 5-0-0 , 1-" 04-0 3-M Plate Offsets 5:0-1-11 0- 0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.15 Vert(LL) -0.01 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.09 Vert(TL) -0.01 4-5 >999 180 BCLL 10.0 Rep Stress Ina YES WB 0.02 Horz(TL) -0.01 3 Na Na BCDL 10.0 Code FBC2004/TPl2002 (Matra) Weight. 16lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 3=106/Mechanical, 4=34/Mechanical, 5=304/0-8-0 Max Ho25=94(load case 5) Max Upliff3=-70(load case 5), 5=131(load case 5) Max Grav3=106(load case 1), 4=62(load case 2), 5=304(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-101/40, 2-3=56/31 BOT CHORD 1-5=-0/94, 4-5=0/0 WEBS 2-5=246/149 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2)'This truss has been designed for a 10.0 psf bottom chord live load nonconarrrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift atjoint 3 and 131 lb uplift at joint 5. LOAD CASE(S) Standard e WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Information avallable from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but Ev reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 CC O 0 o- O H Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required, See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft, spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior 16. approval of a professional engineer. Install and load vertically unless indicated otherwise. MiTek® V0"i © 2004 Mitek® Job Pry Centex Homes, Model 1577 A. ITRmlype 10ty 0 O . iC06-019 EJ5 MONO TRUSS 2 1 �� Job Reference Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property -01 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and and securely seat. or X-bracing, is always required. See BCSI1. 0-1/0 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. c1-2 c2-3 �*For WEBS c3� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all 4 x 2 orientation, locate 0 3 �,�' 3 Cc �,� other interested parties. plates 0 -1 /16" from outside O O �� U 4. Cut members to bear tightly against each other. edge of truss. t- 5. Place plates on each face of truss at each joint and c7-5 csa c5-6 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. — required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff, spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. A M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitele Connected Wood Trusses. Job Truss Truss Type Oty Ply Model 1577 A XOfr019 EJ5P MONO TRUSS 3 1 � 1='(.Pfional) Universal Forest Product, ft. E359, Ft Pierce, Ft. 34"4ames L Shod 6.300 s Dec 1 2005 MTek Industries, Inc. Thu Feb 01 08:03:47 2007 Page 1 5-0-0 5-0-0 Scale =1:9. 4.00 12 T1 1 HNI B1 4x4 = 44 11 3 'DIM 0 1-0-0 1-1 8 5-0-0 140-0 0-1-8 3-10-8 Plate Offsets X 1:0-2-14 E 1:0-1-41-2-1 LOADING (psf) SPACING 24)-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.37 Vert(LL) 0.05 13 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.22 Vert(11) -0.07 13 >821 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a Na BCDL 10.0 Code FBC2004/TPI2002 (Matra) Weight: 17lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-M oc puriins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE Left: 2 X 4 SYP No.2 REACTIONS (Ihfsize) 2=168/Mechanical, 3=48/Mechanical, 1=217/0-3-0 Max Horz1=75(foad case 3) Max UpliR2=101(load case 3), 3=70(load case 3), 1=144(load case 3) Max Grav2=1680oad case 1), 3=96(load case 2), 1=217(load case 1) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=-45/44 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf,, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other five loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of wtlhstanding 101 lb uplift at joint 2, 70 lb uplift at joint 3 and 144 lb uplift at joint 1. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with Mfiek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. 14515 N. Outer Forty, Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCS11 Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside a edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or .Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. CL 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1, 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements, 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others, 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type - Oty Pty Centex Homes, Model 1577 A k06-019 EJSU MONO TRUSS 12 1 Job Reference o tional Universal Forest Product, Inc. E359, FL Pierce, R. 34946, Ja0l" Shoat 6.300 s Dec 1 2005 MiTek Industries, Inc. Thu Feb Ot 08:03:4T 2007 Page 1 5-0-0 5-0-0 Scale =1:11. 5.00 12 Tt 2 61 30 = 4 0 -0 1-0-0 1-4-Quell 5-0-0 � 1-0-0 011-0 3-8-0 Plate Offsets 5:0-1-110-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.15 VeR(LL) -0.01 45 >999 360 MT20 244/190 TCDL 15,0 Lumber Irraepse 1.25 BC 0.09 Vert(1L) -0.01 45 >999 180 BCLL 10.0 Rep Stress Irxx YES WB 0.02 Horz(lL) -0.01 3 n/a n!a BCDL 10.0 Code FBC2004/TPI2002 (Malrbc) Weight. 16Ib LUMBER BRACING TOP CHORD 2 X4 SYP No.2 TOP CHORD Structural wood sheathing d'uectly applied or 5-0.0 cc pudirls. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceding directly applied or 10.0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 3=106/Mechanical, 4=34/Mechanlcal, 5=30M0.8-0 Max Horz5=94(load case 5) Max Uplift3=70(load case 5), 5=131(load case 5) Max Grav3=106(load case 1), 4--62(load case 2), 5=304(load case 1) FORCES (lb) -Maximum Compression/Maximum Tension TOP CHORD 1-2=101/40, 2-3--u6/31 BOT CHORD 15=0/94, 45=0/0 WEBS 25=246/149 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed fora 10.0 psf bottom chord live load noncorxwrtent with any other live loads. 3) Refer to girder(s) for truss to buss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 3 and 131 lb uplift at joint 5. LOAD CASE(S) Standard A WARNING - Verljy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer -not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of The building designee For general guidance regarding � fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component Safe Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Properly j3/q *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. c1-2 c2-3 WEBS oa, 4 3. Provide copies of this truss design to the building cc designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate ��' 3 other interested parties. plates 0 -/ie" from outside 0 O 19U 4. Cut members to bear tightly against each other. edge of truss. CL 5. Place plates on each face of truss at each joint and csa cs-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated byANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from Connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second Is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95A3, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if Indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, I 14 El 151 Installing & Bracing of Metal Plate 2004 Mitek® Connected Wood Trusses. O Job Thus Truss Type - - Cty Ply Centex Homes, Model 1577 A 7(06-019 ERMONO TRUSS 6 1 20F0-00 Job Reference (optional) Universal Forest Product, Inc. E359, FL Pierce,48, James L. Shoal 6.300 s Dec 12005 MTek industries, Inc. Thu Feb 01 08:03:47 2007 Page 1 7-0-0 r %-M 3 Scale = 1:74. 5.00 12 T1 1 3x6 11 2 �{ G� 81 3rz4 = 2QW-00 O -0 4 , 1-0-0 04-0 5-8-0 Plate Offsets 2:0.1-11 0-0-0 LOADING (psf) SPACING 2-0.0 CS! DEFL in (loc) Well L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.39 Vert(LL) -0.04 45 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.26 Vert(M) -0.11 45 >604 180 BCLL 10.0 Rep Stress Inca YES WB 0.03 Hoa(TL) 0.04 3 rJa nla BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weigh: 221b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0.0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0.0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (Ib/s¢e) 3=174/Mechanical, 4=r4Mlechanical, 5=38610-8-0 Max Horz5=131(load case 5) Max Uplift3=11Woad case 5), 5=149(load case 5) Max Grav3=174(load case 1), 4=104(load case 2), 5=386(load case 1) FORCES (lb) -Maximum Compression/Maximum Tension TOP CHORD 1-2=154/56, 2-3=-84/52 BOT CHORD 1-5=-0/131, 45=0/0 WEBS 2-5=358/228 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed fora 10.0 psf bottom chord live load noncorxxrrrentwith any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 3 and 1491b uplift atjoint 5. LOAD CASE(S) Standard A WARNING - VeriJy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite JJ300 Applicability of design parameters and proper incorporation of component is responsibility of building designer -not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI7 Quality Criteria, DSB-89 and BCSI1 Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat, * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates, * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if Indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 cc O 2 U CL O h Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury I . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13, Bottom chords require lateral bracing at 10 ff, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV - Jab* Tnrss Thus Type Oty Pty Centex Homes; Mode11577 A XO6-019 EJ7U MONO TRUSS 9 1 Job Reference o tlonal 20F0-00 Universal Forest Product, Inc. E359, Ft Piems.6j1646, James L Shoaf 6.300 s Dec 1 20051viox—Industries, Inc. Thu Feb 01 08:03'.47 2007 Page 1 7-M 7-0-0 3 Scale = 1:14. 5.00 12 T1 3x6 II 2 61 3x4 = 20}0-00 4 0-4 1-M 114-01 7-0-0 1-0-0 0-4-0 5-8-0 Plate offsets 2:0-1-11 0-0-0 LOADING (pso SPACING 2-0.0 CSI DEFL in (loc) Vdetl Ud PLATES GRIP TCLL 20.0 Plates Increase 125 TC 0.39 Vert(LL) -0.04 45 >999 360 MT20 2441190 TCDL 15.0 Lumber Irxxease 1.25 BC 0.26 Vert(TL) -0.11 45 >604 180 BCLL 10.0 Rep Stress fncr YES WB 0.03 Horz(TL) 0.04 3 n/a n1a BCDL 10.0 Code FBC2004frP12002 (Matrix) WPM lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wool sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid celling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (Ib/s¢e) 3=174/Mechan'ical, 4=64/Mechan'ical, 5=386/0-&0 Max Horc5=131(load case 5) Max Upifft3=11Woad case 5), 5=149(load case 5) Max Grav3=174(load case 1). 4--104(load case 2), 5=386(load case 1) FORCES (lb) - Maximum CompressiordMaximum Tension TOP CHORD 1-2=154/57, 2-3=-84/52 BOT CHORD 15=-0/131, 4-5=0/0 WEBS 2-5=358/228 NOTES 1) Wind: ASCE 7-02;130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load norxoncurrent with any other fire loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift atjoint 3 and 149lb uplift atjoint 5. LOAD CASE(S) Standard A WARNING - Venyy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, r_ Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. cc O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside a. edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator, General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted, 14, Connections not shown are the responsibility of others. 15, Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type. Oly Ply Centex Homes, Model 1577 A XO6-019 F01 FLOOR 2 1 Job Reference (optional - Universal Forest Product, Inc. E359, Ft Pierce, Fl. 34946, James L. Shoal 6.300 s Dec 1 2005 MTek Industries, Inc. Thu Feb 01 08:03:48 2007 Page I. 0-" 1-3-0 ¢9-12 2-M Q 0-112-0-0 4�n C)TMa=1.46. 46 = 46 11 1.54 II 1.5x4 II 4x6 = 3x6 FP= 1.5x4 II 3x5 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 (( rt�l V 3 W 3 W 3 aj W 3 W W 3 W Ip 33 32 31 30 29 28 27 26 5 24 23 22 21 20 19 1.5x4 11 46 = 4x6 = 3x6 FP= 3x6 = 1.5x4 11 1-5x4 11 46 = 1-5-0 0-M 1-5-0 22-3-8 01418 6-5-4 7-5-418-5-41 15-4-4 20-3-8 26-11-8 4-4 0 0-4-8 6-0-12 1-M I-M 6-11-0 4-11-4 1-" 1-M 4-8-0 0-4-8 Plate Offsets X 1:0-3-0,Ed 15:0-1-8E 18:0-3-0E 23:0-1-8 E 29:0-1.8 E 30:0-1-8 Ed ,[33:Edge,04)-121 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.56 Vert(LL) -0.08 30-31 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.57 Vert(TL) -0.11 30-31 >999 240 BCLL 0.0 Rep Stress Ina YES WB 0.20 Horz(TL) -0.02 18 n/a Na BCDL 5.0 Code FBC2004/TPI2002 (Matra) Weight: 153lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 4X2SYP No.2 REACTIONS (lb/size) 1=729/04-0, 18=517/0-0-0, 25=1665/0-5-8 Max Grav 1=757(load case 7),18=576(load case 3), 25=1665(load case 1) FORCES (lb) - Maximum CompressiordMaximum Tension TOP CHORD 1-33=0/7, 18-19=0/6, 1-2=567/0, 2-3=56310, 3-4=1335/0, 45=-1667/0, 5-6=-1667/0, 6-7=1667/0, 7-0=-1369/0, 8-9=-629/49, 9-10=0/1009, 10-11--0/1009, 11-12--0/1009. 12-13=-169/314, 13-14=951/17,14-15=951/17,15-16=897/0, 16-17=404/0, 17-18=-408/0 BOT CHORD 32-33=0/0, 31-32=0/1060, 30-31=011589, 29-30=0N667, 28-29=0/1616, 27-28=0/1107, 26-27=247/134, 25-26=247/134, 24-25=-467/137, 23-24=1571794, 22-23=17/951, 21-22=17/951, 20-21=Of756,19-20=0/0 WEBS 5-30=209/36, 6-29-- 426/0,10-25=93/0,14-23=304/0,15-22=20210, 1-32=0/848, 3.32-789/0, 3-31=0/437, 4-31=40310, 4-30=104/300, 9-25=1154/0, 9-27=0/844, 8-27=-811/0, 8-28=0/467, 7-28=-463f0, 7-29=5/552, 12-25=933/0, 12-24=0/603, 13-24=619/0, 13-23=0/523, 18-20=0/608,16-20=559/0,16-21=-51/224, 15-21=125/158 NOTES Y 1) Unbalanced floor live loads have been considered for this design. 2) Al plates are 3x4 MT20 unless otherwise indicated. 3) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 11 and 26. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - Verify destq, parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with Mffek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 1'/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate X plates 0 - 1/16" from outside a_ edge of truss, o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if Indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section Indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. a. 5. Place plates on each face of truss at each joint and OR embed fully Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11, Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Pty. • Homes, Model 1577 A °* X06-019 F02 FLOOR 9 1 Job Reference a tional Universal Forest Product Inc. E359, FL Pierce, Fl. 34946, James L Shoat 6.300 s Dec 1 20051�iTek industries, Inc. Thu Feb 01 08:03:48 2007 Page 1 04-8 1-3-0 0-9-12 , 2-0-0 1-0-12 , H H-� Scale =1:24. 46 II 1.50 II 1.5x4 II 46 = 1 2 3 4 5 6 7 8 9 v 1, 4 Ivi i? 17 16 15 14 13 12 11 1 1.5x4 It 46 = 46 = 1-5-0 0-0-0 94-$ 6-5-4 7-54 8-54 14-10-8 , 04-8 6-0-12 1-M 1-0-0 6-5-4 Plate Offsets 1:0-3-0 E 13:0-1.8 E 14:0-1-8 Ed 1TE a 0.0-1 LOADING (psf) TCLL 40.0 SPACING 2-0-0 Plates Increase 1.00 CSt TC 0.51 DEFL in (loc) l/defl Ud Vert(LL) -0.09 12-13 >999 480 PLATES GRIP MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.54 Vart(TL) -0.13 12-13 >999 240 BCLL 0.0 Rep Stress Incr YES WB 021 Horz(TL) 0.01 10 n1a Na _ BCDL 5.0 Code FBC2004/TPI2002 (Matrix) Weight 84 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-" oc, bracing. WEBS 4 X 2 SYP No.2 REACTIONS (Ib/size) 10=787/0-1-8, 1=787/0-4-0 FORCES (Ib) - Maximum CompresswrJMaximum Tension TOP CHORD 1-17=0/6, 9-10=781/0, 1-2-594/0, 2-3=590/0, 31=1406/0, 4-5=1802/0, 5.6=1802/0, 6-7=180210, 7-8=1427/0, 8.9=-604/0 BOT CHORD 16-17=0/0, 1r16=0/1109, 14-15=0/1689, 13-14=0/1802, 12-13=0/1692, 11-12=0/1138, 10-11=0/0 WEBS 5-14=310/0, 6-13=254/0, 1-16=0/889, 3-16=-825/0, 3.15=0/472, 4-15=449/0, 4-14=33/466, 9-11=0/908, 8-11=-84810, 8-12=0/459, 7-12-420/0, 7-13=-40/411 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) Provide mechanical connection (by others) of truss to bearing plate atjoint(s)10. 4) Recommend 2x6 strongbacks, on edge, spaced at 1040 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - Ver1Jy design parameters and READ NOTES ON Tffi5 AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Suite #300 Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, W153719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-'/ids * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction, DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13, Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® 1577A •. "-^s�ca�r::�';,�,�:n - X06-019 F03 FLOOR 9 1 Job Reference o tional Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L Slxraf 6.300 s Dec 12005 MTek Industries, Inc. Thu Feb 01 08:03:49 2007 Page 1 0-4-5 1-3-0 2-0-0 0-11-0 , Scale =las. 3x5 11 3x6 = 1 2 3 4 5 6 7 2 W 3 6 W V 15 14 13 12 11 10 9 8 1.5x4 11 1.5x4 11 1.5x4 II 1-5-0 0-0-0 p-4-$ 5-0-8 6-0-8 7-0-8 12-1-0 04-8 4-8-0 1-0-0 1-0-0 5-0-8 Plate Offsets 1:0-3-0 E 4:0-1-8 E e , 5:0-1-8 Ed 9:0-1-8 Ede 15:E a 0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (lac) Udefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.36 Vert(LL) -0.06 10-17 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.51 Vert(TL) -0.07 11 >999 240 BCLL 0.0 Rep Stresslna YES WB 0.16 Horz(TL) 0.01 8 nla rJa BCDL 5.0 Code FBC2004lTPI2002 (Matrix) Weight: 70 lb LUMBER BRACING TOP CHORD 4 X 2 SYP Not TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 8=634/0.1-8, 1=634/0.4-0 FORCES (lb) -Maximum CompressxxNMaximum Tension TOP CHORD 1-15-0l5, 7-8=-628(0, 1-2=-457/0, 23=d53J0, 3-0=1046/0, 45=1163/0, 5.6=104810, 6-7=d66/0 BOT CHORD 14-15=0/0, 13-14=0/846, 12-13=0/1163, 11-12=0/1163,10-17=0/1163, 9-10=0/873, 8-9=0/0 WEBS 412=101/165, 5-11=114/108, 1-14=0/682, 3-14=625/0, 3.13=0/354, 4-13=-394/0, 7-9=01700, 6-9--646/0, 6-10=0/313, 5-10=331/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 8. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3.16d nails. Strongbacks to be.attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect miss backwards. LOAD CASE(S) Standard A WARNING - VeriJy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer -not truss designer. Bracing shown 14515 N. Outer Forty, � Suite #300 Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. O O Job - Tn>ss Truss Type _. .uu.- Qty PN - Fbmes,Model. Symbols PLATE LOCATION AND ORIENTATION 1'/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but E�i2 reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction, DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, 0 cc O U o_ O R Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and OOP embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job , jPIy—:jCentexHomeA4ode11577Ax 1�XO6-019 F04 OaTRTruss Job Reference o 8onal Universal Forest Product, Inc. E359, Ft Pierce, Fl. 34946, James L Shoat 6.300 s Dec 12005 NiTek Industries, Inc. Thu Feb 01 08:03:49 2007 Page 1 0-4-8 1-3-0 1'$-0 I Scale=1:14. 3x5 11 3x4 = 3x4 = 1.5x4 II 3x5 = 1 2 3 13 4 53x4= 6 Ivi 2 W W /W\3 W 12 11 10 9 30 8 3x4 7 1.5x4 II 3x4 = 1.5x4 II 3x4 11 1-5-0 0-0-0 0-4-8 , 8-11-0 04-8 8-6-8 Plate Offsets 1:0-3-0E :0-1-8 Ed , 6:0-2-0 E e :Ed a 0.1-8 :0-1-8 Ede[12:Edge.0-0-121 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) Well Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.36 Vert(LL) -0.04 8-9 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.37 Vwt(TL) -0.06 8-9 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(TL) 0.01 7 rda nla BCDL 5.0 Code FBC2004/TPI2002 (Matrix) Weight: 53lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0.0 oc purlins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0.0 oc bracing. WEBS 4X2SYP No.2 REACTIONS (lb/size) 7=459/Mochan'ical, 1=459/04-0 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-12=0/16, 6-7=-059/0, 1-2=306/0, 2-3-302/0, 3-13=598/0, 4-13=598/0, 45=598/0, 5-0=-315/0 BOT CHORD 11-12=0/0, 10-11=0/598, 9-10=0/598, 8-9=0/573, 7-8=0/0 WEBS 6-8=0/473, 1-11=0/455, 5-8=-409/0, 3-11=457/0, 5.9--43/184, 3-10=-19/117, 4-9=94/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10.0.0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. -. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - V-,ft design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 Cc O * For 4 x 2 orientation, locate X plates 0 - 1/16" from outside n. edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output, Use T, I or Eliminator bracing If indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section Indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. a. 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® " lobes }way. w « .,... ..::Am TrYas •< • " Truax fj pe - - aty ply Centex Homes, Model 1577 A'— - X06-019 F05 FLOOR 1 1 Job Reference (optional Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946. James L Shoaf 6.300 s Dec 12005 MiTek Industries. Inc. Thu Feb 01 08:03:49 2007 Page 1 0-4-8 scale =1:12. 3x5 II 3x4 = 3x4 = 3x5 = 1 2 3 12 4 3x4 = 5 12 3A = 1.5x4 II 1.5x4 II 3x4 = 11 10 9 8 7 6 1.5x4 II 3x4 11 1-5-0 0-M 0-4-8 , 7-6-0 0A-8 7-1-8 Plate Offsets 1:0-3-0E 3:0.1-8 Ed 4:0-1-8Ed 5:0-2-0E e l l:E 0-0-1 LOADING (cast) SPACING 2 0 0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 Plates Increase 1.00 Lumber Increase 1.00 Rep Stress Incr YES Code FBC2004/TP12002 TC 0.34 BC 0.28 WB 0.08 (Matto Vert(LL) -0.02 7-8 >999 480 Vert(TL) -0.03 7-8 >999 240 Hoa(TL) 0.01 6 n/a Na MT20 2441190 Weight: 46 lb LUMBER BRACING TOP CHORD 4 X 2 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 4 X 2 SYP N0.2 REACTIONS (lb/sae) 6=382/0-1.8, 1=382/0-" FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-11=2/13, 5.6=-377/0, 1-2=234/0, 2-3=229/0, 3-12=-04010, 4-12=-W10, 4-5=234/0 BOT CHORD 10-11=0/0, 9.10=0/440, 8-9=0/440, 7-M/440, 6-7=0/0 WEBS 5.7=0/352, 1-10=0/345, 4-7=317/0, 3-10=325/0, 3-9---60/103, 4$=75/87 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-M oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. -, 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - Vergj# design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 O is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component M Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. iTe Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths .Personal Dimensions are In ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required, See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 c2-3 materials on Inadequately braced trusses. WEBS 4 3. Provide copies of this truss design to the building � designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate m N �,3 �� 3 0= other interested parties. plates 0 - I/ie' from outside 0 a. �� T U 4. Cut members to bear tightly against each other. edge of truss. O 5. Place plates on each face of truss at each joint and c7.5 c5a c5-5 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots In 8 7 6 5 b. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available In MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension Is the width NUMBERS/LETTERS. responsibility of truss fabricator, General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension Is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text In the bracing section of the 12. Top chords must be sheathed or purlins provided at output, Use T, I or Eliminator bracing spacing shown on design. If Indicated, ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling Is installed, unless otherwise noted. Indicates location where bearings Uk 14. Connections not shown are the responsibility of others. (supports) occur, Icons Vary but 15. Do not cut or alter truss member or plate without prior reaction section Indicates joint approval of a professional engineer. 9F number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction, MiTek® DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Joblt-4r,4*!5"!-tr'RN!i-c,ITrussType Ply Centex Homes' Modsi 1577A jOty— X06-019 FG1 SPECIAL 1 31job Reference (optional) UU*Rpl Forest Product Inc. E359, Ft. Pierce, Ft. 34946, James L Shoaf 6.300 s Dec 12005 LITak Industries, Inc. Thu Feb 0108:03:49 200"age 1 3-5-8 5-5-11 8-7-8 11-9-5 13-9-8 17-3-0 3-5-8 2-0-3 3-1-13 3-1-13 2-0-3 3-5-8 Scale 1:29.0 30 = 414 = 30 = 1.5x4 11 3x4 = 4x114 = 30 1 2 330 4 5 6 7 a W2 1 Lm.j W2 —j W4 Li B11 L BZJ N6 5X8 17 15 18 14 19 20 13 12 21 11 22 10 23 24 A 2X5 It 46 = 3x10 = 5x10MT18H= 46 = 2X5 11 5)C8 = 0-0-0 0-0-0 3-5-8 5-5-11 8-7-8 11-9-5 13-9-8 17-3-0 3-5-8 2-M 3-1-13 3-1-13 2-0-3 3-5-8 Plate Offsets 2:0-7-0,0-1-121, [7:0-7-0.0-1-121, [9:0-3-12.0-2-81, [11:0-2-4,0-2-0], [14:0-2-4,0-2-0], [16:0-3-12.0-2-81 LOADING (psf) SPACING 2-0-0 CS11 DEFIL in (loc) Ydell Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.82 VerKLL) -0.34 13 >600 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.85 Vert(TL) -0.52 13 >391 240 MT18H 2441190 BCLL 0.0 Rep Stress Incr NO WB 0.55 Horz(TL) 0.08 9 rda rVa BCDL 6.0 Code FBC20041rPI2002 (Matrix) Weight: 302 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 TOP CHORD Structural wood sheathing directly applied or 3-10-9 oc pudinis, except end verticals. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 *Except! W4 2 X 6 SYP SS, W4 2 X 6 SYP SS REACTIONS (lb/size) 16--7469/0-2-15(inpkt 0-1-8),9=698610-3-8 FORCES (lb) - Maximum CompressiorVMaximum Tension TOP CHORD 1-16--39410,1-2--151510,2-3--18795/0,3-4=2124510,4-5--2124510,5.6--21245/0.6-7=18897/0,7.8--171810.8-9---400/0 BOT CHORD 16-17=0/12829,15-17=0/12829.15-18--0/12829,14-18=0/12829,14-19=0/18795,19-20--0/18795,13-20--0/18795,12-13=0/18897,12-21=0118897,11-21=0/18897,11-22--0/13031, 10-22--0/13031, 10-23=011 3031, 23-24--0113031, 9-24=0/1 3031 WEBS 2-16--1218410, 2-1 5--OfT70, 2-14=0[7086, 3-14=1 427/0, 3-13--0/2648, 5-113=1 8610. 6-13=0/2538, 6-11 =1 3B9/0, 7-11 =0/6967, 7-1 0=0/843. 7-9=1 218310 NOTES 1) 3-ply truss to be connected together with I Od (0. 13 1"x3") nails as follows: Top chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 -1 raw at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 oc. Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) All plates are MT20 plates unless otherwise indicated. 4) WARNING: Required bearing size at joint(s) 16 greater than input bearing size. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 777 lb down at 0-2-12, 624 lb down at 0-2-12, 624 lb down at 2-3-12, 777 lb down at 2-3-12, 777 lb down at 4-3-12, 624 lb down at 4-3-12,624 lb down at 6-3-12, 777 lb down at 6-3-12, 777 lb down at 8-3-12, 624 lb down at 8-3-12,624 lb down at 10-3-12, 777 lb down at 10-3-12. 777 lb down at 12-3-12, 624 lb down at 12-3-12, 624 lb down at 14-3-12, 777 lb down at 14-3-12, and 777 lb down at 16-3-12, and 624 lb down at 16-3-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Floor. Lumber lncrease=1.00, Plate Iricrease=1.00 Uniform Loads (plo Vert: 11-8=100, 9-16--10 Concentrated Loads (lb) Vert: 16-14011(F=777, B=-624) 117=4401(1`=777. 13 -624) 18=1401(F=777, B=-624) 19=11401(F=-777. B=624) 20=1401(1`=777, B=-624) 21=11401(1`=777, B=-624) 22=11401(F=777, B=-624) 23=4401(F=777, B=-624) 24=1401(F=777, B--424) A WARNLYG - Verify design and READ NOTES ON THIS AND REVERSE SLIDE BEFORE USE. 14516 N. Outer Forty, parameters Design valid for use only with Mirrek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite 11300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery; erection and bracing, consult ANSI/TPH Quality Criteria, DSB-89 and BCS11 Building Component MiTel Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. 1 Symbols PLATE LOCATION AND ORIENTATION 13/q * Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. 0 cc O U o_ O Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties, O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design, if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek® DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. m Job -.R .:... Tnrss e s Type Oly Ply Centex Ftorr,eti, Mxlel 1577X X06-019 FG2 1 1 TSrPECLAL Job Reference o ticnal Urb" Forest Product Inc. E359, Ft Pierce, Fl. 34946, James L. Shoaf D-0-0 6.300 s Dec 1 2005 MTek 6ustries, Inc. Thu Feb 01 08:03:50 ge 1 3-10-15 7-6-6 11-1-13 14-9-4 17.8-1 20-6-14 , 23-5-11 26-M 3-10-15 3-7-7 3-7-7 3-7-7 2-10-13 2-10-13 2-10-13 3-2-5 Scale =1:45 3x4 II 3z10 = 1.5x4 11 3x8 = 1.5x4 11 3x6 = 3x6 = 1.5x4 II 3x8 = 2x5 11 1 2 3 21 4 5 6 7 22 8 9 10 W 2 3 W 8 U Di 0 19 18 23 17 16 14 24 13 12 1 06 = 2x5 11 3x4 = 2x5 11 5x6 = 4x14 = 2x5 II 3x4 = 2x5 11 4x6 = 0-0-0 0-0-0 0-0-0 3-10-15 i 7-" i 11-1-13 14-9-4 17-8-1 20-6-14 23-5-11 i 2648-0 3-10-15 3-7-7 3-7-7 3-7-7 2-10-13 2-10-13 2-10-13 3-2-5 Plate Offsets 2:0-3-8,0-1-81,[4:0-3-8,0-1-81,[7:0-2-8.D-1-81,[15:0-7-0,0-1-12l,[20:0-1-12,0-1-121 LOADING (psf) SPACING 2-0-0 CS! DEFL in (Icc) Udefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.91 Vert(LL) -0.21 18 >813 480 MT20 2441190 TCDL 10.0 Lumber Increase 1.00 BC 0.72 Vert(TL) -0.33 18-19 >527 240 BCLL 0.0 Rep Stress Ircr NO WB 0.97 Horz(TL) 0.05 11 Na n/a 5.0 Code FBC2004frP12002 (Matrix) Weight-. 144 Ito LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 *Except' TOP CHORD Structural wood sheathing directly applied or 3-1-7 oo purlins, except end verticals. T2 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0.0 oo bracing. BOT CHORD 2 X 6 SYP SS WEBS 2 X 4 SYP No.2 •Except• W5 2 X 6 SYP SS, W5 2 X 6 SYP SS, W5 2 X 6 SYP SS REACTIONS (lb/s'¢e) 20=1020/0-1.5, 11=783/0-1.8, 15=3226/0.5.8 Max Grav20=1056(load case 2), 11=846(load case 3), 15=3226(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-20=-198/0, 1-2=257/0, 2-3=3169/0, 3-21=-3169/0, 4-21=3169/0, 4-5=0/1175, 5-6=0/1175, 6-7=0/1175, 7-22=2029/0, 8-22=2029/0, 8-9=2029/0, 9.10=169/0, 10-11=158/0 BOT CHORD 19-20=0/2480, 18-19--0/2480, 18-23=0/3169, 17-23=0/3169,16-17=0/3169, 15-16=0/3169, 14-15=0/2029, 14-24=0/2029,13-24=0/2029, 12-13=0/1595, 11-12=0/1595 WEBS 2-20=2357/0, 2-19-0/164, 2-18=150f731, 3-18=297/0, 4-17=0/617, 4-15=-4347/0, 5-15=-036/0, 7-15=3114/0, 7-14=0/630, 8-13=230/0, 9-13=242/474, 9-12=0/153, 9-11=1556/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Concentrated loads from layout are not present in Load Case(s): #41 st chase Floor, #5 2nd chase Floor, #6 3rd chase Floor, #7 4th chase Floor. 3) Provide mechanical connection (by others) of truss to bearing plate atjoint(s) 20, 11. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-" oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 533 lb down at 8-7-12, and 5331b dawn at 19-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the face of the muss are rroted as front (F) or back (B). LOAD CASE(S) Standard 1) Floor. Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-21=100, 21-22=200, 10-22=100, 11-20=10 Concentrated Loads (lb) Vert: 23=533(F) 24=-533(F) A WARNING - Verijy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MRek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely Seat, or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 01-2 cz-3 WEBS c3� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate 0 6 �,� ��' 3 cc other interested parties. plates 0 - /ie" from outside O �p6 U 4. Cut members to bear tightly against each other. edge of truss. O 5. Place plates on each face of truss at each joint and c7-8 csa ce s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection, dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be ofthe species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M ITeko DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Mitek® Connected Wood Trusses. VC7`Q VW\ �ww.:„r:..•=��=�R•+ry^.^-:..n.0 T�+,�rr..wx�xt+»nrr�.,.�as-+.. � TfI18S Type"wR�'`^r.:�wrm�r..um�.�nc��mu;wu: �nn�.a� C�ItBiC FfOlI1BS: bIDda11577 A'i#'�'s1R�9E`d35L+F'r..n:.z�.r�m'.va X06-019 FG3 SPECIAL 2 1 Job Reference 0 (optional) Universal Forest Product 19, FL Pierce, Fl. 34946, James L. Shoal 6.300 s Dec 12005 tutiTek industri MiTel Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 cc O * For 4 x 2 orientation, locate For 0 - 1/16" from outside a edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7. 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO BEARING SBCCI Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 96-31, 95-43, 96-2071, 96-67, 84-32 4922, 5243, 5363, 3907 9667, 9730, 9604B, 9511, 9432A 0 0 E NDRO 0qQ ■ EQ1 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or .Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all M other interested parties. O U 4. Cut members to bear tightly against each other. a. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® .- cerdexFronres.l�lodellsnA•��;��",,,.4�t - /� /� O-" X06-019 HJ2 MONO TRUSS 1 1 Job Reference 6onal Universal Forest Product. Inc. F_359, FL Pierce, Fl. 34946, James L Shoaf 6.3k®ec 12005 MTek Industries, Inc. Thu Feb 01 08:03:50 2007 Page 1 4-0-13 3 4-0-13 Scale =1:7. 2 3.54 V2 SIMPSON T, W, MTS16 131 3x4 = g 4 m-la-fl 5 0 -0 3-9-4 4-0-13 3-9-4 0-3-9 LOADING (psf) SPACING 2-0.0 CS! DEFL in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.54 VwKLL) 0.00 5 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.42 Vert(TL) 0.00 45 >999 180 BCLL 10.0 Rep Stress Ina NO WB 0.05 Horz(TL) -0.06 3 Na Na BCDL 10.0 Code FBC20041TP12002 (Matrix) Weight 14 lb LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 4-0-13 cc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2X4SYPNo.2 REACTIONS (lb(s¢e) 3=335/Mechanical, 4=277/Mechanical, 5=95210-11-5 Max Horc5=54(load case 3) Max Uplift3=-335(load case 1), 4=277(load case 1), 5=-601(load case 3) Max Grav3=198(load case 3), 4=190(Ioad case 3), 5=952(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-49/55, 2-3=-109/56 BOT CHORD 1-6=-0154, 5-6=-0/54, 4-5=0/0 WEBS 2-5=577/338 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20f : TCDL=4.2psf, BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Al plates are 1.5x4 MT20 unless otherwise indicated. 4) Refer to girders) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 335 lb uplift at joint 3,-277 lb uplift at joint 4 and 601 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)12lb down and 20lb up at 1-5-12, and 12lb down and 20 Ib up at 15-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=70, 14=20 Concentrated Loads (lb) Vert: 6=20(F=10, B=10) WWARNING - Veryfij design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite 1/300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designee Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1. 0-yid' 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z cz-s materials on inadequately braced trusses. WEBS g_ 4 3. Provide copies of this truss design to the building O designer, erection supervisor, property owner and all *Forpla4 x 2 orientation, locate m �,�3 3 other interested parties, tes 0 - /1e" from outside 0 8 U 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-8 ce-7 ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated b symbol shown and/or y y BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14, Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16, Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek@ DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Mitek® Connected Wood Trusses. b Truss Type ay, Ply'-- Ewa : ,rw.w wd..• 1577 i4 1C0ntaxHomes.K4DW X06-019 HJ5 MONO TRUSS 1 1 2M Job Reference o tional Universal Forest Product, Inc. E359, Ft Pierc�-t,(14946, James L Shoal 6.300 s Doc 12005 MTek Industries, Inc. Thu Feb 01 08:03:50 2007 Pagel 3-10-5 7-0-14 3-10-5 3-2-9 •=1 3.54 ff2 4 T1 1 B1 Ll 3x4 = 5 3 0-0-03x6 II 1-5-0 1-7-1 7-0-14 1-5-0 0-2-2 5-5-13 Plate Offsets 1:0-3-100-0.3 1:0-1-51511 LOADING (psi) SPACING 2-" CS! DEFL in poc) Udall Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 T,C 0.71 Vert(LL) 0.19 1-3 >425 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.40 Vert(M) -0.23'- 1-3 >356 180 BCLL 10.0 Rep Stress Ina NO WB 0.00 Horz(TL) -0.00 2 Na Na BCDL 10.0 Code FBC2004/TPI2002 (Matra) Weight: 23 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0.0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEDGE Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 2=208/Machanical, 3=52(Mechanical,1=276/044 Max Horz1=93(load case 3) Max Uplifl2=136(load case 3), 3=99(load case 3),1=-208(load case 3) Max Grav2=208(load case 1), 3=116(load case 2), 1=276(load case 1) FORCES (lb) - Maximum CompressbWaximum Tension TOP CHORD 14=-56/0, 24=-16/47 BOT CHORD 1-5=0/0, 3-5--0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 136 lb uplift at joint 2, 99 lb uplift at joint 3 and 208 lb uplift at joint 1. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support -concentrated load(s) 2.Ib down and 26 lb up at 4-3-11, and 2 lb down and 26 lb up at 4-3-11 on top chord, and 17 lb up at 4-3-11, and 17lb up at 4-3-11 on bottom chord. The designtselection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=70, 1-3=-20 Concentrated Loads (lb) Vert: 4=52(F=26, B=26) 5=28(F=14, B=14) A WARNING - Verffy design and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, parameters Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Ei Symbols PLATE LOCATION AND ORIENTATION 13/, *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots, LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, 0 O U e. O Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII I. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 WWI N�1 Job-----"-.--._._. ..Truss .----��.".- Truss Type .. _....------- .._ Oly ..Ply. - Centex Homes:•AAode11577 A'........_.: -�__.�.. -.__. -ram-_.. X06-019 HJ5A MONO TRUSS 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, FL Pierce, R. 34946. James L Shoaf p-0-0 8.3no s Dec 1 2005 Wak Industries, Inc. Thu Feb 01 08:03:51 2D07 Page 1 3-10-5 7-0-14 3-10-5 3-2-8 3 Scala = 3.54 F12 6 2 SIMPSON T1 MTS16 11 B1 3x4 = 7 5 8 4 0 2-9-15 3-3-10 7-0-14_ 2-9-15 0-5-11 3-94 LOADING (PSI) SPACING 2-" CS! DEFL in (loc) Ildefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.55 Ver4LL) -0.03 " >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.41 Vert(M) 0.03 4-5 >999 180 BCLL 10.0 Rep Strew Incr NO -_ WB 0.03 Horz(TL) -0.10 3 rda Na BCDL 10.0 Code FBC2004fTP12002 (Matrix) Weight: 23lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-" oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEBS 2X4SYPNo.2 REACTIONS (lb/size) 3=49/Mechanical, 4=161Mechanical, 5=535/0-11-5 Max Horz5=94oad case 3) Max Uplift3=33(load case 3). 4=16(load case 1), 5=304(load case 3) Max Grav3=49(load case 1), 4=35(load case 3), 5=535(load case 1) FORCES (lb) - Maximum Compression'Maximum Tension TOP CHORD 1-2=-90/56, 2-6=-48/0, 3-6=-40f7 BOT CHORD 1-7=-0/93, 5-7=-0/93, 5-8=-010, 4-8=-0/O WEBS 2-5-362/216 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load noncon current with any other live loads. 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Refer to girders) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 33 lb uplift at joint 3, 16 lb uplift at joint 4 and 304 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)11 lb down and 42 lb up at 4-3-11 on top chord, and 12 lb down and 20 lb up at 1-5-12, 12lb down and 20lb up at 1-5-12, and 29lb up at 4=3-11,.and 9 lb up -at 4-3-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 1-4=-20 Concentrated Loads (lb) Vert: 6=42(B) 7=20(F=10, B=10) A WARNING - Verifg design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with M[Tek connectors, This design is based only upon parameters shown, and is for an individual building component. 14515 N. Outer Forty, Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Qualify Criteria, DSB-89 and BCSII Building Component Well ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 1'/a *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g, diagonal and securely seat. or X-bracing, is always required. See BCSI1. 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 cz-a materials on inadequately braced trusses. WEBS c3� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate �,� ��' 3 0 other interested parties. plates 0 - /1e" from outside o �a6 U 4. Cut members to bear tightly against each other. edge of truss. OR 5. Place plates on each face of truss at each joint and c7-e csa cs-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16, Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. .lob �._,.__ .. , . _ .:a,,,, . ;<.- Truss _.. - l- - - _ ...,,.,,,.�,.w , .-.- Mde1XO6-019 1TrussTyPe--- 117111Y-7Homes; HJ5P MONO TRUSS 1ference o t onal ptiTek Universal Forest Product, Inc. E359, Ft Piece* 34946. James L Shoaf 6.300 s Dec 1 2005 Industdes, Inc. Thu Feb 01 08:03:51 2007 Page 1 3-10-9 7-0-14 3-10-9 3-2-or Sole =1:11. 2.83 FIF 7 2 Tt 1HVY B1 4x6 11 g g 5 4 0-0-0 1-5-0 1-7-1 7-0-14 1-5-0 0-2-2 5-5-13 Plate Offsets 1:0.1-6 1-10 1:0-5-2,Ed 5:D-2-15 0-2-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) [/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.33 Vert(LL) 0.03 1-6 >999 360 MT20 244119D TCDL 15.0 Lumber Increase 1.25 BC 0.41 Vert(TL) -0.04 1-6 >999 180 BCLL 10.0 Rep Stress Inxr NO WB 0.14 Horz(TL) 0.01 5 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matra) Weight: 29 lb LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 6-M oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 8-1-12 oc bracing. WEBS 2X4SYP No.2 WEDGE Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 3=92/Mechanical, 5=264/Mechanical, 1=334/044 Max Horz 1=75(load case 3) Max Upid3=-55(load case 3). 5=219(load case 3), 1=240(load case 3) FORCES (lb) - Maximum CompressionMlaximum Tension TOP CHORD 1-2=790/553, 2-7=-42/4, 3-7=15/16 BOT CHORD 1-6=-589/747, 6-8=589f747, 5-8=-589/747, 4-5=0/0 WEBS 2-6=-132/184, 2-5=-780/615 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category ill; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Al plates are 4x4 MT20 unless otherwise indicated. 4) Refer to girders) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 55 lb uplift at joint 3,.219 lb uplift at joint 5 and 240 lbupliftat joint-1. - — ------ 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 28 lb down and 39 lb up at 4-3-11, and 28 lb down and 39 Ib up at 4-3-11 on top chord, and 16 lbdown and 12 lb up at 4-3-11, and 16 Ib down and 12 Ib up at 4-3-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pI0 Vert: 1-3=-70, 1-4=-20 Concentrated Loads (lb) Vert: 7=57(F=-28, B=-28) 8=16(1`=-8, B=-8) A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component. 14515 N. Outer Forty, Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/14 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside n edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 EE. U'Ks AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 197. at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection, 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® 0 ,1�xl�irq+71-'�Fa Tntea'Type ... PItY"""" Centex Homes;ModeI15T7'Avm�s,�w, 906-019 HJSU MONO TRUSS loty,—I 1 1 Job Reference Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. 1. Additional stability bracing for truss system, e.g, diagonal Apply plates to both sides of truss or X-bracing, is always required, See BCSI1. and securely seat. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. c,-z cz-s o c3 4 3. Provide copies of this truss design to the building oWEBS designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate v �,� 3 �3a 3 other interested parties. plates 0 -' /ie" from outside O yaa6 U 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-e csa ce-6 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7, Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8, Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber, PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9, Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second i s to camber for dead load deflection, dimension is the length parallel 10, Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11, Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek@ DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Mitek® Connected Wood Trusses. ' job­—�" ' Tn1sa ,—..-IThiss _ _ _ , _ Qh, ^ - ply- Centez X06-019 HJ7 MONO TRUSS 2 1 Job Reference (optional)201.0-m Universal Forest Product Inc. Fes, ffL Pierce, FI. 34946, James L Shoaf 6.300 s Dec 12005 PATek Industries, Mc. Thu Feb 01 08:03:51 2007 Page 1 • 5-10-4 9-10-13 5-10-4 4-0-9 scels: 3/ 10 a5a 1z 3 9 Tt W2 W1 3x6 II 2 1 B1 11 7 12 6 5 1.5x4 11 2%0 0-0-0 1-5-0 0-10-1 Q 5-8-15 9-10-13 1-5-0 0-5-11 3-10-5 4-1-13 Plate Offsets 2:0.1-9 0-" LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.40 Vert(LL) -0.03 6-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.47 Vert(TL) -0.09 6-7 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.12 Hongn) -0.04 4 Na n/a BCDL 10.0 Code FBC20041TP12002 (Matra) Weight: 39 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-M oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid calling directly applied or 10-0.0 oc bracing. WEBS 2X4SYP No.2 REACTIONS (lb/size) 4=153/Mechanical, 5=224/Mechanical, 8=524/0-11-6 Max Horz8=131(load case 3) Max UpliR4=-85(load case 3), 5=75(load case 3), 8=2390oad case 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=387/89, 2-9=-439/117, 3-9=-415/126, 3-10=56/1, 4-10=29/35 BOT CHORD 1-8=81/382, 8-11=176/382, 7-11=176/382, 7-12=176f382, 6-12=176/382, 5-6=0/0 WEBS 3-7=0/126, 3-0=419/193, 2$=3021163 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf,, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 85 lb uplift at joint 4, 75 lb uplift at joint 5 and 239 lb uplift at joint 8. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)11 lb down and 42lb up at-4-3-11, 11 lb down and 42 lb , up at 4-3-11, and 36 Ib down and 42 Ib up at 7-1-10, and 36 Ib down and 421b up at 7-1-10 on top chord, and 221b down at 7-1-10, 221b down at 7-1-10, and 29 lb up at 4-3-11, and 29 lb up at 4311 on bottom chord. The designlselection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular, Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=70, 1-5=20 Concentrated Loads (lb) Vert: 9=84(F=42, B=42)10=73(F=36, B=36) 12=27(F=14, B=-14) A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Suite #300 Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION �3�4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 In O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside n. edge of truss. R *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but E��F reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16, Install and load vertically unless indicated otherwise. © 2004 MiteV 0' JZ06-019 HJ7U MONO TRUSS 2 1 Job Reference o floral 20F0-0 Universal Forest Product Inc. Fes, fft Pierce. Fl. 34946, James L Shoaf 6.300 s Dec 1 2005 btTek Industries, Inc. Thu Feb 01 08:03:52 2007 Page 1 « 5-10-4 9-10-13 5-10-4 4-0-9 ScalS:3/ - 10 3.54 12 3 9 T1 W2 W1 3x6 II 2 1 l 131 11 7 12 6 5 1.5x4 II 20W4 0-0-0 1-5-0 0-10-1q 5-8-15 9-10-13 1-5-0 0-5-11 3-10-5 4-1-13 Plate Offsets 2:0-1-9 0-M LOADING (psi) SPACING 24).0 CSI DEFL in (loc) Wall L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.40 VwgLL) -0.03 6-7 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.47•- Vert(TL) -0.09 6-7 >999 180 BCLL 10.0 Rep Stress Ina NO WB 0.12 Horz(TL) -0.04 4 Na rda BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 39 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-M oc pudins. BOT CHORD 2 X 4 SYP N0.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (Ib/size) 4=153/Mechanrcel, 5=224/Mechank:alt 8=524/0-11-5 Max Horz8=131(load case 3) Max Uplift4=4WIoad case 3), 5=75(load case 3), 8=239(load case 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=387/89, 2-9-439/117, 3-9=-415/126, 3-10=56/1, 4-10=29/35 BOT CHORD 1-8=81/382, 8-11=176/382, 7-11=-176/382, 7-12=-176/382, 6-12=-176/382, 5.6=0/0 WEBS 3-7=0/126, 3-0=-419/193, 2-8=302/163 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psft BCDL=3.Ops . Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; t Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 85 lb uplift at joint 4, 75 lb uplift at joint 5 and 239 lb uplift at joint 8. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 11 lb down and,42 lb up at 4-3-11, 11 lb down and 42Ib up at 4-3-11, and 36 lb down and 42Ib up at 7-1-10, and 36lb down and 42Ib up at 7-1-10 on top chord, and 22 lb down at 7-1-10, 22lb down at 7-1-10. and 29 lb up at 4-3-11, and 29lb up at 4-3-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). • LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pli) Vert: 1-4=-70, 1-5=20 Concentrated Loads (lb) Vert: 9=84(F=42, B=42)10=73(F=-36, B=-36)12=-27(F=-14, 13=14) A WARNING - Ver!,Fy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an Individual building component. 14515 N. Outer Forty, " Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI7 Building Component ii Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. t Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-1/ids * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 soffware or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots, Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur, Icons vary but reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 rr O U a O Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ffspacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise, © 2004 Mitek® Truss "^e--._..,_ Tru53TyPe ...�:_ -., -_ .. py._. .. Cehtexfiomee:Modef _ X06-019 MV2 VALLEY 1 1 Job Reference o tional Universal Forest Product. Inc. E359, FL 1ti�MFl. 34946. James L. Shoat 6.300 s Dec 1 20051Yifek Industries, Inc. Thu Feb 01 08:03:52 2007 Page 1 2-M 2-M Scale =1:5.1 5.00 12 1 T B1 0 2-0-0 i 2-0-03 4' LOADING (psf) SPACING 2-0.0 CSI DEFL' in (loc) I/de8 Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.02 Vert(LL) nda - Na 999 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.01 Vert(TL) Na - rt/a 999 BCLL 10.0 Rep Stress Ina YES WB 0.00 Haz(TL) -0.00 2 Na n/a BCDL 10.0 Code FBC20041TPI2002 (Mab*) Weight: 5lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid calling directly applied or 10-M oc bracing. REACTIONS (lb/size) 1=45/2-0-0, 2=35/2-0-0, 3=10/2-M Max Horz1=24(load case 5) Max Upliftl=9(load case 5), 2=24(load rase 5) Max Grav1 =45(load case 1), 2=35(load case 1), 3=20(load case 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=15/13 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. - 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Gable requires continuous bottom chord bearing.. 4) Bearing atjoinnt(s) 2 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 9 lb uplift at joint 1 and 24 lb uplift at joint 2. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Suite #300 Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 -1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89; Design Standard for Bracing. BCSI1; ".. Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, 0 ir O U N Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 cc O x U o_ O AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required, See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane atjoint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® - w MAP OFBOUNDAR YSUR VEY FOR: CENTEX HOMES LEGAL DESCRIPTION: Lot 2, Block 9, Palm Breezes Club, according to the Plat thereof as recorded in Plat Book 49, Page 32 through 35, of the Public Records of St. Lucie County, Florida. Said lands situate, lying and being in St. Lucie County, Florida. Containing 4,050 square feet more or less. STREET ADDRESS: 9334 TREASURE COAST STREET FORT PIERCE, FLORIDA LEGEND IL R. R OFFICIAL RECORD BOOK P. C. P. PERMANENT CONTROL POINT U. E. UTILITY EASEMENT P. C. POINT OF CURVATURE A E. DRAINAGE EASEMENT P. R. C POINT OF REVERSE CURVATURE P. R PLAT BOOK P. C. C. POINT OF INTERSECTION PG PAGE I/P IRON PIPE T. D. B TOP OF BANK P. P. POWER PaE E. IL W. EDGE OF WATER S/T SWING TIE K G.V. A NATIONAL GEODETIC VERTICAL DATUM 6 K OVERHEAD SG, FT. SDUARE FEET .Sm STRADDLED R/W RIGHT OF WAY F.PLL FLORIDA POWER L LIGHT CURD. COVERED O/S OFFSET FNA FOUND ELEC. ELECTRIC I/R IRON ROD RES. RESIDENCE WD NAIL IN DISK REF. REFERENCE N/T NAIL IN TAB CONST. CONSTRUCTION Cow- CONCRETE CC) CALCULATED CH) MEASURED EL ELEVATION C P) PLAT P. R. K PERMANENT REFERENCE MONUMENT MO MONUMENT K K HAND HOLE CENTERLINE A W.E. DESIGN WATER ELEVATION L K E. LAKE AND MAINTENANCE EASEMENT (K R.) NON -RADIAL K V. A L NON -VEHICULAR ACCESS LINE B. C. R. BRWARD COUNTY RECORDS S. S, E. SAFE SIGHT EASEMENT P. A E. PEDESTRIAN ACCESS EASEIEHT L A E. LIMITED ACCESS=EASEMENT ® EXISTING WATER SERVICE ON OVERHEAD UTILITY LINES # EXISTING LIGHT POE EI EXISTING SANITARY CONNECTION ( EXISTING FIRE HYDRANT 0 EXISTING ELECTRICAL SERVICE ® EXISTING DRAINAGE MAN HOLE aEXISTING CABLE SERVICE D4 EXISTING WATER VALVE EXISTING CATCH BASIN ® EXISTING FPL PAD Q8 EXISTING SANITARY MAN HOE • EXISTING CLEAN OUT O EXISTING BELLSOUTH RISER FLOW ARROWS EXISTING ELEVATION PROPOSED ELEVATION SURVEY NOTES: 1. BEARINGS SHOWN HEREON ARE BASED ON THE PLAT OF PALM BREEZES CLUB, (P.B 49, PGS. 32-35. S.LC.R.) 2. BELOW GROUND IMPROVEMENTS AND/OR ENCROACHMENTS IF MAY, WERE NOT LOCATED. 3. ELEVATIONS SHOWN HEREON ARE BASED ON THE NATIONAL GEODETIC VERTICAL DATUM (N.G.V.D.) OF 1929. 4. THE UNDERSIGNED AND DAMD k GERCHAR, INC. MAKE NO REPRESENTATIONS OR GUARANTEES AS TO THE INFORMATION REFLECTED HEREON PERTAINING TO EASEMENTS, RIGHTS OF WAY, SETBACK LINES, AGREEMENTS AND OTHER MATTERS, AND FURTHER, THIS INSTRUMENT IS NOT _,r is TYPICAL LOT LAYOUT FRONT BLDG SETBACK 12.50 FEET REAR BLDG SETBACK 110 FEET SIDE BLDG SETBACK 1 6 FEET S/TE L OCA T/ON MAP (N. T. S.) ' OCT 0 3 2007 PUBLIC WORKS ST. LUCIE COUNTY. FL Lo T-`- 90Z 933a / rc¢,ture 4* sj .f .. ------.._...--- - -- - - -- - --- - 6 _--E- -- ---WABSTRACTED SHOWNHEREON WERE NOT MA E -- OABSTRACTED FOR RIGHTS OF WAY AND OR EASEMENTS OF RECORD. 61 5. THERE HAS BEEN NO SEARCH OF THE PUBLIC RECORDS PERFORMED BY THIS FIRM. SURVEY IS CLASSIFIED CHAPTER 61G17-6, CODE, O� 6 D fD �— c) 6. 7. THIS A BOUNDARY SURVEY BY FLORIDA ADMINISTRATIVE THIS MAP UANT OFF BOUNDARYHAPTER 4SU ORVEY IFLORIDAT VALIDSTATUTES, AWITHOUT AMENDED. SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA / / ! / / T T LICENSED SURVEYOR AND MAPPER. $LO�� S. ALL PROPERTY CORNERS ARE SET 1/2' IRON ROD WITH CAP STAMPED 'LB6935- UNLESS OTHERWISE NOTED. 9. BENCHMARK OF ORIGIN: ST. LUCIE COUNTY BENCHMARK LN. k A.: ELEVATION- 45.251 10. THE N.F.I.P. FLOOD MAPS HAVE DESIGNATED THE HEREON DESCRIBED PROPERTY LIE WITHIN FLOOD ZONE 'X', BASE FLOOD ELEVATION N/A, COMMUNITY No. 120285, PANEL 0175-F WITH A FIRM EFFECTIVE DATE OF 8/19/91. REVISIONS DATE BY CKD CKD FB/PG LOT2. BLOCK 9 SEAL SCALE: 1' = 30' JOB NO: 06-223 AVID & fB/PG: CAD. FILE: PALM BREEZES CL UB THOEESSI J. DSUR FOR THE FIRM PROFESSIONAL SURVEYOR AND MAPPER N/A F:\ealtez\Pc,*3\Lzea\Bloda Blodc3\lot 2 ERCHAR INC. � (P.B 49, PAGES 32-32, S.L. C.R.) FLORIDA REGISTRATION NO. 5821 DAwD & GERCHAR, INC. 6935 SIGNATURE DATE: N DRAWN BY: SN DATE: 04/12/07 SURVEYORS AND MAPPERS 12075 N.W. 40th Street Bay 1 CKD 1ST BY: CKD 2ND BY: PROJ. FILE: FINAL SURVEY 10/02/07 EC AC AC FILE DATE OF LAST FIELD SURVEY: 10/01/07 SN SN PALMBREZ AL Coral Springs, Florida 33065 (954) 340-4025 -Fax: (954) 340-8584 FORMBAORD SURVEY 6/15/07 1 AC SN SN I FILE MAP OFBOUNDAR YSUR VEY FOR: CENTEX HOMES. LEGAL DESCRIPTION: Lot 2, Block 9, Palm Breezes Club, according to the Plat thereof as recorded in Plat Book 49, Page 32 through 35, of the Public Records of St. Lucie County, Florida. Said lands situate, lying and being in St. Lucie County, Florida. Containing 4,050 square feet more or less. STREET ADDRESS: 9334 TREASURE COAST STREET FORT PIERCE, FLORIDA LE O& ELM A OFFICIAL RECORD BOOK P. C. P. PERMANENT CONTROL POINT U. E. UTILITY EASEMENT P. C. POINT OF CURVATURE A E. DRAINAGE EASEMENT P.R.C. POINT OF REVERSE CURVATURE P. A PLAT BOOK P. C. C. POINT OF INTERSECTION PG. PAGE I/P IRON PIPE T. a B TOP OF BANK P. P. POWER POLE E a W. EDGE OF WATER S/T SWING TIE N. G. V. A NATIONAL GEODETIC VERTICAL DATUM 0. H. OVERHEAD SG. FT. SQUARE FEET .STM STRADDLED R/W RIGHT OF WAY F.PLL FLORIDA POWER L LIGHT CVRA COVERED O/S OFFSET FML FAD ELEC. ELECTRIC I/R IRON ROD RES. RESIDENCE N/D NAIL IN DISK REF. REFERENCE N/T NAIL IN TAB CONST. CONSTRUCTION CONIC. CONCRETE (L) CALCULATED CFO MEASURED EL ELEVATION (P) PLAT P. R. K PERMANENT REFERENCE MONUMENT NOL MONUMENT H H. HAND HOLE CENTERLINE A W. E DESIGN WATER ELEVATION L M. E. LAKE AND MAINTENANCE EASEMENT CK R. ) NONERADIAL N. V. A L NOR -VEHICULAR ACCESS LINE A C. R. BROWARD COUNTY RECORDS S. S. E. SAFE SIGHT EASEMENT P. A. E PEDESTRIAN ACCESS EASEMENT L A E LIMITED ACCESS EASEMENT ® EXISTING WATER SERVICE OH OVERHEAD UTILITY LINES EXISTING LIGHT POLE EI EXISTING SANITARY CONNECTION 3( EXISTING FIRE HYDRANT 0 EXISTING ELECTRICAL SERVICE ® EXISTING DRAINAGE MANHOLE Qi EXISTING CABLE SERVICE w EXISTING WATER VALVE ® EXISTING CATCH BASIN ® EXISTING FPL PAD OS EXISTING SANITARY MAN FOE • EXISTING CLEAN OUT O EXISTING BELLSOUTH RISER FLOW ARROWS �7�..0_ $k EXISTING ELEVATION PROPOSE] ELEVATION SURVEY NOTES: 1. BEARINGS SHOWN HEREON ARE BASED ON THE PUT OF PALM BREEZES CLUB. (P.B 49. PGS. 32-35. S.LC.R.) 2. BELOW GROUND IMPROVEMENTS AND/OR ENCROACHMENTS IF ANY, WERE NOT LOCATED. t 3. ELEVATIONS SHOWN HEREON ARE BASED ON THE NATIONAL GEODETIC• VERTICAL DATUM (N.G.V.D.) OF 1929. 4. THE UNDERSIGNED AND DAVID do GERCHAR, INC. MAKE NO REPRESENTATIONS OR GUARANTEES AS TO THE INFORMATION REFLECTED HEREON PERTAINING TO EASEMENTS, RIGHTS OF WAY, i SETBACK LINES, AGREEMENTS AND OTHER MATTERS, AND FURTHER, THIS INSTRUMENT IS NOT I INTENDED TO REFLECT OR SET FORTH ALL SUCH MATTERS. SUCH INFORMATION SHOULD BE OBTAINED AND CONFIRMED BY OTHERS THROUGH APPROPRIATE TITLE VERIFICATION. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR RIGHTS OF WAY AND OR EASEMENTS OF RECORD. 5. THERE HAS BEEN NO SEARCH OF THE PUBLIC RECORDS PERFORMED BY THIS FIRM. 6. THIS SURVEY IS CLASSIFIED A BOUNDARY SURVEY BY CHAPTER 61G17-6, FLORIDA ADMINISTRATIVE CODE, PURSUANT TO CHAPTER 472.027, FLORIDA STATUTES, AS AMENDED. 7. THIS MAP OF BOUNDARY SURVEY IS NOT VAUD WITHOUT A SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. B. ALL PROPERTY CORNERS ARE SET 1/2' IRON ROD WITH CAP STAMPED 'LB6935- UNLESS OTHERWISE NOTED. 9. BENCHMARK OF ORIGIN: ST. LUCIE COUNTY BENCHMARK LN. & A.: ELEVATION 45.251 10. THE N.F.I.P. FLOOD MAPS HAVE DESIGNATED THE HEREON DESCRIBED PROPERTY LIE WITHIN FLOOD ZONE 'X', BASE FLOOD ELEVATION N/A, COMMUNITY No. 120285. PANEL 0175—F WITH A FIRM EFFECTIVE DATE OF 8/19/91. REVISIONS I DATE I BY I1et I2n,IFB/PG CKD CKD FINAL SURVEY FORMBAORD SURVEY EC JAC JAC I FILE AC ISNISNI FILE r���6 ,31i 3 I LOT 2, BLOCK-9. PALM BREEZES CLUB (P.B 49, PAGES 32-32, S.L. C.R.) �LO SEAL 9, 50 )0 1 � 1 i L0 �1{ 1 SCALE: 1' = 30' FB/PG: THOEDORE J. DAVID FOR THE FIRM N/A PROFESSIONAL SURVEYOR AND MAPPER FLORIDA REGISTRATION NO. 5621 DRAWN BY: DAVID & GERCHAR, INC. 6935 SN SIGNATURE DATE: (3CD tsr 121 D2NIDATE OF LAST BY: Y., FIELD SURVEY: 10/01/07 SN SN Z-UT 90Z. TYPICAL LOT LAYOUT FRONT BLDG SETBACK 12.50 FEET REAR BLDG SETBACK 10 FEET SIDE BLDG SETBACK 6 FEET S/TE L OCA TION MAP (N. T S.) OCT 0 3 2007 PUBLIC WORKS 933V TrNu1urc 66Y XY- JOB NO: 06-223 CAD. FILE: F. \cwtex\Pdmbre=e9N Blodc3\Lot 2 DATE: 04/12/07 PROJ. FILE: PALMBREZ AVID & ERCHAR, INC. SURVEYORS AND MAPPERS 12075 N.W. 40th Street Bay 1 Coral Springs, Florida 33065 (954) 340-4025 -Fax: (954) 340-8584 MAP OFBOL17VDAR YSUR VEY FOR: CENTEX HOMES LEGAL DESCRIPTION: Lot 2, Block 9, Palm Breezes Club, according to the Plat thereof as recorded in Plat Book 49, Page 32 through 35, of the Public Records of St. Lucie County, Florida. Said lands situate, lying and being in St. Lucie County, Florida. Containing 4,050 square feet more or less. STREET ADDRESS: 9334 TREASUR COAST STREET FORT PIERCE, FLORIDA LEGEND O. R. 8. OFFICIAL RECORD BOOK P. C. P. PERMANENT CONTROL POINT U. E. UTILITY EASEMENT P. C. POINT OF CURVATURE D. E. DRAINAGE EASEMENT P. R. C. POINT OF REVERSE CURVATURE P. B. PLAT BOOK P� C� C. POINT OF INTERSECTION PG. PAGE I/P IRON PIPE T. O. B TOP OF BANK P. P. POWER POLE E. 0. W. EDGE OF WATER S/T SWING TIE N. & V.D. NATIONAL GEODETIC VERTICAL DATUM 0. H. OVERHEAD SO, FT. SQUARE FEET STR. STRADDLED R/W RIGHT OF WAY F. P&L. FL13RIDA POWER & LIGHT CVRD. COVERED O/S OFFSET ` FND. FOUND ELEC. ELECTRIC I/R IRON ROD RES. RESIDENCE N/D NAIL IN DISK REF. REFERENCE N/T NAIL IN TAB CONST. CONSTRUCTION CONC. CONCRETE (C) CALCULATED (M) MEASURED EL. ELEVATION ( P> PLAT P. R. M. PERMANENT REFERENCE MONUMENT MON. MONUMENT H. N HAND HOLE CENTERLINE D. W. E. DESIGN WATER ELEVATION L M.E. LAKE AND MAINTENANCE EASEMENT (N. R.) NON -RADIAL N. V. A L. NON -VEHICULAR ACCESS LINE S. L. C. R. ST. LUCIE COUNTY RECORDS S. S. E. SAFE SIGHT EASEMENT P. A E. PEDESTRIAN ACCESS EASEMENT L.A.E. LIMITED ACCESS EASEMENT ® INDICATES PROPOSED WATER SERVICE - OH OVERHEAD UTILITY LINES # INDICATES PROPOSED LIGHT POLE t7 PROPOSED SANITARY CONNECTION INDICATES PROPOSED FIRE HYDRANT A PROPOSED ELECTRICAL SERVICE O INDICATES PROPOSED DRAINAGE MAN HOLE PROPOSED CABLE SERVICE PROPOSED WATER VALVE ® INDICATES PROPOSED CATCH BASIN ® PROPOSED FPL PAD QS INDICATES PROPOSED SANITARY MAN HOLE INDICATES PROPOSED DRAINAGE MAN HOLE SURVEY NOTES: 1. BEARINGS SHOWN HEREON ARE BASED ON THE PLAT OF PALM BREEZES CLUB, (P.B 49, PGS. 32-35, S.LC.R.) 2. BELOW GROUND IMPROVEMENTS AND/OR ENCROACHMENTS IF ANY, WERE NOT LOCATED. 3. ELEVATIONS SHOWN HEREON ARE BASED ON THE NATIONAL GEODETIC VERTICAL DATUM (N.G.V.D.) OF 1929. } 4. THE UNDERSIGNED AND DAVID & GERCHAR, INC. MAKE NO REPRESENTATIONS OR GUARANTEES AS TO THE INFORMATION REFLECTED HEREON PERTAINING TO EASEMENTS, RIGHTS OF WAY, SETBACK LINES, AGREEMENTS AND OTHER MATTERS, AND FURTHER, THIS INSTRUMENT IS NOT INTENDED TO REFLECT OR SET FORTH ALL' SUCH MATTERS. SUCH INFORMATION SHOULD BE OBTAINED AND CONFIRMED BY OTHERS THROUGH APPROPRIATE TITLE VERIFICATION. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR RIGHTS OF WAY AND OR EASEMENTS OF RECORD. 5. THERE HAS BEEN NO SEARCH OF THE PUBLIC RECORDS PERFORMED BY THIS FIRM. 6. THIS SURVEY IS CLASSIFIED A BOUNDARY SURVEY BY CHAPTER 61G17-6, FLORIDA ADMINISTRATIVE CODE, PURSUANT TO CHAPTER 472.027, FLORIDA STATUTES, AS AMENDED. 7. THIS MAP OF BOUNDARY SURVEY IS NOT VALID WITHOUT A SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. B. ALL PROPERTY CORNERS ARE SET 1/2' IRON ROD WITH CAP STAMPED 'LB6935' UNLESS OTHERWISE NOTED. 9. BENCHMARK OF ORIGIN: ST. LUCIE COUNTY BENCHMARK L.N. & A: ELEVATION= 45.251 10. THE N.F.I.P. FLOOD MAPS HAVE DESIGNATED THE HEREON DESCRIBED PROPERTY LIE WITHIN FLOOD ZONE "X', BASE FLOOD ELEVATION N/A, COMMUNITY No. 12D285, PANEL 0175—F WITH A FIRM EFFECTIVE DATE OF 8/19/91. L �� 9 f 19 9 p,L Lp`G� Nil ,�LO 4 61.31' 36 LOT 9 �5 00 RLp� ✓ 21.98', 0 0 CD-8.47 LO 9 0 tvop/E i r' 21.98' N FORMBOARD o CA FLOOR ; FIEVATION.24.78 N Cn 6 B TYPICAL LOT LAYOUT FRONT BLDG SETBACK 12.50 FEET REAR BLDG SETBACK 10 FEET SIDE BLDG SETBACK 6 FEET L OCA TION MAP (N. T. S.) *NO7E• AT THE 77ME OF FORMBOARD SURVEY, THE TOP BOARD (RECESS BOARD) WAS NOT IN PLACE. WHEN TOP BOARD (RECESS BOARD) IS PLACED, THE ELEVA77ON SHOULD BE a12 FEET HIGHER AND THAT SHOULD BE 7HE SAME AS 7HE FINISHED CONCRETE WHEN POURED. REVISIONS DATE BY CKD cKD FB/PG SCALE: JOB No: AVID & LOT 2 BLOCll FB/PG: CAD. FILE: F:\centex\PoIrnbreezes\BIocks\ 1-i R1 HAR, INC. P14L1� BRBEZE,S' CLUB THOEDORE J. DAVID FOR THE FIRM N/A Bloek3\Lot 2 11JJ111��\t/11111\ PROFESSIONAL SURVEYOR AND MAPPER FLORIDA REGISTRATION N0. 5821 DRAWN BY: DATE: DAVID & GERCHAR, INC L # 6935 SN 04/12/07 SURVEYORS AND MAPPERS (P.B 49, PAGES 32-32, S.L. C.R.) SIGNATURE DATE: �S a� CKD 1ST CKD 2ND 12075 N.W. 40th Street Bay 1 DATE OF LAST BY: BY: PROJ. FILE: Coral Springs, Florida 33065 FORMBOORD SURVEY 6/15/07 AC SN SN FILE FIELD SURVEY: 6/14/07 SN SN PALMBREZ (954) 340-402-5 -Fax: (954) 340-8584 MAP OFBOUNDAR YSUR VEY FOR. - CENTEX HOMES LEGAL DESCRIPTION: Lot 2, Block 9, Palm Breezes Club, according to the Plat thereof as recorded in Plat Book 49, Page 32 through 35, of the Public Records of St. Lucie County, Florida. Said lands situate, lying and being in St. Lucie County, Florida. Containing 4,050 square feet more or less. _ frig , TYPICAL LOT LAYOUT FRONT BLDG SETBACK 12.50 FEET REAR BLDG SETBACK 110 FEET SIDE BLDG SETBACK 1 6 FEET S/TE 9334 TREASUR COAST STREET STREET ADDRESS: FORT PIERCE, FLORIDA 5 613 F LEGEND O 1 �QO g kS �D ,.. L0` 3 g r . . ; . EL R. B. OFFICIAL RECORD BOOK P. C. P. PERMANENT CONTROL POINT L O�K L0� P. C. POINT OF CURVATURE B'�, N• - U. E, UTILITY EASEMENT �1 ,4.OW ` Q, D. E. DRAINAGE EASEMENT P. R. C. POINT OF REVERSE CURVATURE Y s� _ P. R PLAT BOOK P. C, C. POINT OF INTERSECTION GJ �, pp, - PG. PAGE I/P IRON PIPE �j 7- - QP laml�.. T. O. B TOP IF BANK P. P. POWER POLE 2 p � �0 ,jO,C i � ,h E. 0. W, EDGE OF WATER S/T SWING TIE p N G. V. D. NATIONAL GEODETIC VERTICAL DATUM 0. K OVERHEAD 'p SO. FT. SQUARE FEET STR. STRADDLED p_ R/W RIGHT OF WAY F. PLL FLORIDA POWER L LIGHT s$ CVRD COVERED Ef/S OFFSET N>`Nw' �Q,� P LOCH TION MAP (N. T.S.) FND. FOUND ELEC, ELECTRIC Jj '� �.� �• I/R IRON ROD RES. RESIDENCE�- N/D NAIL IN DISK REF. REFERENCE N N/T NAIL IN TAB CONST. CONSTRUCTION�_ 05"�l�' CONC. CONCRETE C C) CALCULATED CP, '} `� QEI? # CM) MEASURED EL. ELEVATION N� (P) PLAT P. R. M PERMANENT REFERENCE MONUMENT p- O� Ste' mm MONUMENT H. HL HAND HOLE �- �� CENTERLINE D. W. E. DESIGN WATER ELEVATION �)'a'l"' 8:50'- ( V�j , L¢li E LAKE AND MAINTENANCE EASEMENT N; li R.) NON -RADIAL Cn ',�NS� 10: G.1 ,-Qy' %jD N V. A L. NON -VEHICULAR ACCESS LINE S. L. C. R. ST. LUCIE COUNTY RECORDS 1,0 9 _ - , • GM .� R�. g�' o -� o q - D �. f - q S. S. E. SAFE SIGHT EASEMENT P. A E. PEDESTRIAN ACCESS EASEMENT LO L !s,J)` L A E. LIMITED ACCESS EASEMENT INDICATES PROPOSED WATER SERVICE $ Qom' •Y•'"Y � � �1 OH OVERHEAD UTILITY LINES # INDICATES PROPOSED LIGHT POLE L j ��.0"k O..Py_ III PROPOSED SANITARY CONNECTION INDICATES PROPOSED FIRE HYDRANT ,&OQ DB D PROPOSED ELECTRICAL SERVICE (+Fj• '� 5 0 PROPOSED CABLE SERVICE {�, YYY QD INDICATES PROPOSED DRAINAGE MAN HOLE { �,Y � \p PROPOSED WATER VALVE INDICATES PROPOSED CATCH BASIN �' , ® PROPOSED FPL PAD INDICATES PROPOSED INDICATES PROPOSED DRAINAGE MAN HOLE / 61,+r(�4 ' SURVEY NOTES: 1. BEARINGS SHOWN HEREON ARE BASED ON THE PLAT OF PALM BREEZES CLUB, (P.B 49, PGS. 32-35, S.LC.R.) 2. BELOW GROUND IMPROVEMENTS AND/OR ENCROACHMENTS IF ANY, WERE NOT LOCATED. 3. ELEVATIONS SHOWN HEREON ARE BASED ON THE NATIONAL GEODETIC VERTICAL DATUM (N.G.V.D.) OF 1929. 4. THE UNDERSIGNED AND DAVID & GERCHAR, INC. MAKE NO REPRESENTATIONS OR GUARANTEES AS TO THE INFORMATION REFLECTED HEREON PERTAINING TO EASEMENTS, RIGHTS OF WAY, SETBACK LINES, AGREEMENTS AND OTHER MATTERS, AND FURTHER, THIS INSTRUMENT IS NOT INTENDED TO REFLECT OR SET FORTH ALL SUCH MATTERS. SUCH INFORMATION SHOULD BE OBTAINED AND CONFIRMED BY OTHERS THROUGH APPROPRIATE TITLE VERIFICATION. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR RIGHTS OF WAY AND OR EASEMENTS OF RECORD. 5. THERE HAS BEEN NO SEARCH OF THE PUBLIC RECORDS PERFORMED BY THIS FIRM. B. THIS SURVEY IS CLASSIFIED A BOUNDARY SURVEY BY CHAPTER 61017-6. FLORIDA ADMINISTRATIVE CODE, PURSUANT TO CHAPTER 472.027, FLORIDA STATUTES, AS AMENDED. 7. THIS MAP OF BOUNDARY SURVEY IS NOT VALID WITHOUT A SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 8. ALL PROPERTY CORNERS ARE SET 1/2• IRON ROD WITH CAP STAMPED •LB6935• UNLESS OTHERWISE NOTED. 9. BENCHMARK OF ORIGIN: ST. LUCIE COUNTY BENCHMARK L.N. & A.: ELEVATION= 45.251 10. THE N.F.I.P. FLOOD MAPS HAVE DESIGNATED —THE —HEREON —DESCRIBED PROPERTY LIE WITHIN FLOOD L�ONC• _* BASE FLOOD ELEVATION N/A, COMMUNITY No 120285 PANEL 0175=_ErW_ H A FIRM EFFECTIVE DATE OF B/19/91. PO ROiO � E ,P 61.3'136 rJ L0� O I MIN. SETBACK REG. FRONT I1 ko V v SIDES LP 10 ZN1Cy. U r4V T(t ti LAS N REVISIONS DATE BY ,st CKD zna C KD FB�PG LOT 2, BL®CK 9 PALM BREEZE'S CLUB (P.B 49, PAGES .32-32, S.L.C..R.) SEAL — _ SCALE: 1• = 30' JOB No: 06-223 AVID & ERCHAR, INC SURVEYORS AND MAPPERS PG FB : / N/A : CAD. FILE: F: \centez\PBlocks Block3\Loek3\Lot 22 DEAN M. GERCHAR FOR THE. FIRM PROFESSIONAL SURVEYOR AND MAPPER FLORIDA REGISTRATION NO. 5829 DAVID & GERCHAR, INC. L.B. # 6935 SIGNATURE DATE: ' 04/13/07 DRAWN BY: SN DATE: 04/12/07 10750 Wiles Road Coral Springs, Florida 33076 (954) 340-4025 -Fax: (954) 255-0735 CKD 1ST BY: SN CKD 2ND BY: SN PROD. FILE: PALMBREZ