Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS_2DATE 01/31/0T PAGE 1 �. Universal Forest Product RE: X06-003 CENTEX HOMES Model 2227 A Site Information: Project Customer: CENTEX HOMES Project Name: Model 2227 A Lot/Block: 3a49 Model: Model 2227 A Address: Subdivision:Morningside City: Ft. Pierce State: FL Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions Design Code: FBC2004/TPI2002 Design Program: MiTek 20/20 6.3 Wind Code: N/A Wind Speed:140mph Design Method: User defined Roof Load:20.0-15.0-10.0-10.0 Floor Load: 40.0,10.0,0.0,5.0 D Date 1 X06-003 A01 01/31/07 26 X06-003 CJ5U 01/31/07 2 X06-003 A02 r 01/31/07 27 X06-003 D01 01/31/07 3 X06-003 A03 01/31/07 28 X06-003 D02 01/31/07 4 X06-003 B01 01/31/07 29 X06-003 E01 01/31/07 5 X06-003 B02 01/31/07 30 X06-003 EG7 01/31/07 6 X06-003 B03 01/31/07 31 X06-003 EG7A 01/31/07 7 X06-003 B03A 01/31/07 32 X06-003 EJ2 01/31/07 8 X06-003 B04 01/31/07 33 X06-003 EJ5 01/31/07 9 X06-003 B04A 01/31/07 34 X06-003 EJ6 01/31/07 10 X06-003 B05 01/31/07 35 X06-003 EJ6U 01/31/07 11 X06-003 B06 01/31/07 36 X06-003 ERU 01/31/07 12 X06-003 B08 01/31/07 37 X06-003 FG1 01/31/07 13 X06-003 B09 01/31/07 38 X06-003 FG2 01/31/07 14 X06-003 C01 01/31/07 39 X06-003 GE1 01/31/07 15 X06-003 CO2 01/31/07 40 X06-003 HJ2 01/31/07 16 X06-003 CO3 01/31/07 41 X06-003 HJ5 01/31/07 17 X06-003 C04 01/31/07 42 X06-003 HRA 01/31/07 18 X06-003 C05 01/31/07 43 X06-003 HRU 01/31/07 19 X06-003 CA 01/31/07 44 X06-003 MV2 01/31/07 20 X06-003 CAE 01/31/07 45 1 X06-003 5V4 01/31/07 21 X06-003 ' CJ1U 01/31/07 46 X06-003 1701 01/31/07 - 22 X06-003. CJ3 01/31/07 47 X06-003 F02 01/31/07 23 X06-003 CJ3A 01/31/07 48 X06-003 F03 01/31/07 24 X06-003 CJ3S 01/31/07 49 X06-003 F04 tslttl:,o;�/ 1/07 25 X06-003 CJ3U 01/31/07 50 X06-0 F06 The truss drawing(s) refrenced above have been prepared by MiTek Industries, Inc. `�®®� ; �``✓• �,1L EAi q S!''a under my direct supervision based on the parameters provided by UFP-Ft.Pierce, Fl\,� Truss Design Engineer's Name: Tan, Seng-Chaff I� O. 6' �J - My license renewal date for the state of Florida is February 28,2007. NOTE: The seal on these drawings indicate acceptance of AppR ED STA E 0... OF professional engineering responsibility solely for the trussSeng-Chai Lic #46765 � ••. O D A,: �►�.' �� ` components shown.Tan p The suitability and use of this component for any particular 345 Alhambra PL west Palm Beach, FL 33405 islS`4 ''���irrrrt buildingis the responsibility of the building designer, per P tY 9 9 P ' MiTek Industries, InG, FL Cert.#6634 rtttttlN���``` FEB 0 1 2007 ANSI/TPI-1 Chapter to *9VAwat I r;,ee t#1B 4e MF' hf �v ryt �v rJ i `f di t�R fcQi �Irc�n� ba'rripon3e�5f.��1515�N�.pOuter Forty,I n all f�oeorg, s desi n Is ase on u on aroma er s o a o w �lt�jj fl5 of I IWI� l r iif®�IBfSromponent Is responsibility of building designer -not truss designer. Brack shown Chestefield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing. consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component ' MiTek ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint, unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation,,locate Plates 0-,1/16" from outside edge offtruss. - *This symbol indicates the required`. direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request:"-� PLATE SIZE TFie first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 Ir O U o_ 0 Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 c TEE-�LOK ���■eve AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1, 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise, © 2004 Mitek® Universal Forest Product' DATE 01/31/07 PAGE 2 ICE: X06-003 CENTEX HOMES Model 2227 A Site Information: Project Customer: CENTEX- HOMES Project Name: Model 2227 A Lot/Block: Model: Model 2227 A Address: Subdivision:Morningside City: Ft. Pierce State: FL 51 X06-003 F07 01/31/07 52 X06-003 F08 01/31/07 53 X06-003 F09 01/31/07 J� `o Seng-Chaff Tan, FL Lic #46765 t45 Alhambra PL est Palm Beach, FL 33405 iTek Industries, Inc. L Cert.#6634 "s STA �••a V �E OF ORi,pP �,: pppNi� nttUtN\\\ FEB 0 1 2007 A WARNING - Verify design parameters and READ NOTES oN TBIs AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with M[Tek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component . M ITe �� Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. , Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 cc 0 *For 4 x 2 orientation, locate plates 0 - 1/16" from outside o edge of truss. O- *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE i The first.dimension is the width 4 X 4 perper}dicular to slots. Second dimension is.the length parallel to slots. L 1. LATERAL BRACING Indicateci'by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate 'Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII . 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all M other interested parties. 0 U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or puriins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless Indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty Ply Centex Homes, Model 2227 A • X06-003 A01 MONO HIP 1 1 Job Reference (options]) Universal Forest PrrBjlfftpinc. E359, FL Pierce, R. 34946, James L. Shoat 6.300 s Dec 12005 AATek Industries, Inc. Wed Jan 31 14:27:09 2007 Page 1 , 4-10-6 5-5-4 10-8-8 1,'1-0-p 4-10-0 3-6-14 2-3-4 0-3-8 Scale =1:18. 3 4 4z4 II T2 4.00 12 4x4 2 W3 W2 W2 T1 _ 1 1 1 JX7 B, d s s 4x4 = 5x7 It 0-7-4 0-0-0 1-0-0 11-;12 8-5-4 10-8-8 , 1-0-0 0-1-12 7-3-8 2-3-4 Plate Offsets 1:0-0-81-24 1:0.1-14 Ed 5:E 0-3-0 LOADING (psi) SPACING 2.0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.69 Vert(LL) 0.30 1$ >419 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.52 Vert(TL) -0.39 1-0 >324 180 BCLL 10.0 Rep Stresslrtcr YES WB 0.16 - Hwz(TL) 0.01 7 Na Na BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight 51 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-7-14 oc bracing. WEBS 2 X 4 SYP No.2 WEDGE Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 1=482/0-3$, 8=45610-3$ Max Horz1=128(load case 3) Max Uplift1=333(load case 3), 8=349(load case 3) FORCES (Ib)-Maximum CompressiordMaximumTension TOP CHORD 1-2=-898/537, 2-3=339/216, 3-4=267/219, 5-7=92/138, 47=171/146 BOT CHORD 1-6=-612/825, 5.6=219/267 WEBS 2-6=-0131436, 3-(r--250I308, 4-8=-164/115, 7-6=-06/59 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20fh TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) Provide adequate drainage to prevent water ponding. 3) *This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x6 MT20 unless otherwise indicated. 5) Bearing at joint(s) 8 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 333 Ito uplift at joint 1 and 349 lb uplift at joint 8. _ LOAD CASE(S) Standard A WARNING -Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MlTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 - is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component � Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0'1/16" 0 Ir O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside a edge of truss. o *This symbol indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 * Plate location details available in MiTek 20/20 software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT The first dimension is the width NUMBERS/LETTERS. 4. X 4 perpendicular to slots. Second dimension is the length parallel to slots. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A BEARING ` Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety. Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate `Connected Wood Trusses. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all pC other interested parties. O U 4. Cut members to bear tightly against each other. a. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber Is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty Ply Centex Homes, Model 2227 A X06-003 A02 MONO HIP 2 1 Job Reference (optional) Universal Forest Pr�F� nc. 59, FL Pierce, Fl. 34946, James L Shoaf 6.300 s D� 1 2005 biTek Industries, Inc. Wed Jan 31 14:27:09 2007 Page 1 r 7-0-0 10-8-8 '1�1-0-0 7-0-0 3-8-8 0-3-8 scale = 1:1 B. 5x6 = 5x8 — 2 3 T2 4.00 72 W3 W1 W1 T1 1 � 6 B7 d 5 4 5x7 II 0-7-4 0-0-0 , 1-0-0 1-1-12 7-0-0 10-8-8 , , 140-0 0-1-12 5-10-4 3-8-8 Plate Offsets 1:0.0-81-24 1:0-3-6 0-0- 3:0.2-12 0.2-8 4:E a 03-8 LOADING (psf) SPACING 2-0-0 CSI DER in (Ice) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.53 Vert(LL) 0.15 1-5>820 360 MT20 2441190 TCDL . 15.0 Lumber Increase 1.25 BC 0.71 Vert(TL) -0.19 1-5 >665 180 LL BC10.0 Rep Stress [nor xYES WB 0.14 Horz(TL) 0.01 6 n!a nla BCDL 10.0 Code FBC20041TPI2002 (Matra) Weigh: 491b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing d""mactly applied or 6-0-0 oc purlirrs, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 8312 oc bracing. WEBS 2X4SYP No.2 WEDGE Left: 2 X 4 SYP No.2 REACTIONS (IWsae) 1=482/03-8, 7=1aG/0-3$ Max Horz 1=106(load case 3) Max Uplift1=339(load case 3), 7=-343(load case 3) FORCES (Ib) -Maximum Compression/Maximum Tension TOP CHORD 1-2=766/480, 2-3--642/497, 4.6=7/16, 3-6=2251157 BOT CHORD 1-5=-504/657, 4-5=-30/46 WEBS 2-5=-238/131, 3-5=569f725, 3-7=239M82, 6-7=33/44 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) Provide adequate drainage to prevent water ponding. 3) 'This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise indicated. 5) Bearing atjoint(s) 7 considers parallel to grain value using ANSIlTPI 1 angle to grain formula. Building designer should verify rapacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 339 lb uplift at joint 1 and 343 lb uplift at joint 7. LOAD CASE(S) Standard A WARNING -Verify design parameters and READ NOTES ON TSIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with M1Tek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not Truss designer. Bracing shown Chesterfield, MO 63017 y bracing to Insure stablliiy.during construction Is the responsibility of the Is for lateral support of Individual web members only.Additional temporarSafety erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component � Information available from Truss Plate Institute, 83 'O of Io Drive Madison. 7 0 Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. 0 fr O U a O h Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. * Plate location details available in Welk 20/20 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design, if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: 'MI ANSI/TPI1: National Design Specification. for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, ,Installing & Bracing of Metal Plate ® © 2004 Miteke Connected Wood Trusses. " Job Truss Truss Type City Ply Centex Homes, Model 2227 A ' „ X06-003 A03 MONO HIP 2 1 Job Reference (optional) Universal Forest PrcgW(jnc. E359, Ft Pierce, Fl. 34946, James L. Shoal' 6.300 s Dec 12005 MiTek Industries, Inc. Wed Jan 31 14:27:10 2007 Page 1 r 5-0-0 � 7-t3$ � 10-8-8 11 5-0-0 2-8-8 3-0-0 0-3-8 Scale =1:18. 2 9 3 10 4 4.00 72 T2 W4 Wt W1 T1 t t 7 Y Bt d 6 it 12 5 - 4x6 = 5x7 II ' 0-7-4 0-0-0 r 1`0-0 5-0-0 10$-8 ' 1-0-0 4-0-0 5..8-8 Plate Offsets 1:0.0-81-2r1 1:0-2-14 Ea 2:0-2-00-2-4 , [5:Edoe,0-1-121 LOADING (psf) SPACING 240-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.72 Vert(LL) 0.08 5-0 >999 360 MT20 244/190 TCDL 15.0 Lumbar increase 1.25 BC 0.83 Vert(TL) -0.10 5-6 >999 180 BCLL 10.0 Rep Stress Ina NO WB 0.20 Horz(TL) 0.02 7 n!a rJa BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weigh: 491b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-6.7 ac purlins, excel end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5515 x bracing. WEBS 2 X 4 SYP No.2 WEDGE Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 1=755/0-3$, 8=822/0-3-8 Max Horz 1=76(load case 3) Max Uplifi1=564(load case 5), 8=636(load case 3) FORCES (lb) -Maximum CompressionlMaximum Tension TOP CHORD 1-2=-1766/1311, 2-9=162811286, 3-9=1628/1286, 3-10=261/224, 410=261/224, 5-7=531/647, 47=155/194 BOT CHORD 1-0=1272(1617, 6-11=-898/1192, 11-12--898/1192, 5-12=-898/1192 WEBS 2-6=-172/246, 3-0=-094/524.35=-1084/785, 4.8=-310/269, 7.8=-100/125 NOTES s 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft TCDL=4.2psf; BCDL=3:Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) Provide adequate drainage to prevent water ponding. 3) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise indicated. 5) Bearing at joints) 8 considers parallel to grain value using ANSIffPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 564 Ib uplift at joint 1 and 6361b uplift atjoint 8: 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)120 lb down and 115 Ito up at 5-0-0, and 98Ib down and 80Ib up at 7-1-1, and 98 lb down and 80 lb up at 9-1-1 on top chord, and 268 lb down and 297 lb up at 5-0-0, and 56 lb down and 76 lb up at 7-1-1, and 56 lb down and 761b up at .9-1-1 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=70, 2-4=-70, 1-5=-20 Concentrated Loads (lb) Vert: 2=-120(F) 6=268(F) 9=98(F)10=98(F)11=28(1`)12=28(F) A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MRek connectors. This design 1s based only upon parameters shown, and is for an Individual building component. Suite 0300 Applicability of design parameters and proper Incorporation of component 1s responsibility of building deslgner- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional Temporary bracing to insure stability during construction Is the responsibility of the -erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI7 Quality Criteria, DSB-89 and BCSII Building Component � Symbols PLATE LOCATION AND ORIENTATION 13/. *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but lip reaction section indicates joint number where bearings occur.. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, a Installing & Bracing of Metal Plate Connected Wood Trusses. 0 cc O U a O P Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A MiTek� TEE-LOK AWN■�v� AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane atjoint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator, General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Ply Centex Homes, Model 2227 A X06-003 B01 COMMON 3 1 Job Reference (optional) Unive"Fpi®st Product, Inc. E359, FL Pierce, Fl. 34946, James L. SlwaF 6.300 s Dec 12005 MTek Industries, Inc. Wed Jan 31 14:27: 7 Page 1 6-2-15 11-6-2 17-0-0 22-5-14 27-9-1 34-0-14-0 0 , 6-2-15 5-3-3 5-5-14 5-5-14 5-3-3 6-2-15 Scats =1:56. ax6 = s.00 12 s 46 � 46 a 5 7 a 3 W2 W2 9 4 W 2 10 1 11 I 3x6 = 3x6 = 18 17 16 15 14 13 12 3x8 11 4x6 = 3x8 = 4x6 = 3x8 II -0 1-8�-0 9-4-10 17-0-0 24-7-6 , 32-8-0 3�3-0 1-0-0 8-0-11 7-7-6 7-7-6 8-0-11 0-4-0 0-4-0 1-0-0 Plate Offsets 4:03-0 E 8:03-0 E 12:0-0-0 0.0-0 18:0.4-12 0-1-8 LOADING (psi) SPACING 2-0.0 CSI DEFL in (loc) I/defl Lid PLATES GRIP TCLL 20.0 Plates Increase 1.25 TIC 0.80 Vert(LL) -0.24 1315 >999 360 MTZO 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.72 Vert(IL) -0.71 13-15 >528 180 BCLL 10.0 Rep Stresslna YES WB 0.49 Horz(lL) 0.11 12 nla n/a _ BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weigh: 164 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 'Except' TOP CHORD Structural wood sheathing directly applied or 2-8-14 oc puriins. T1 2 X 4 SYP SS, T1 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 7-11-11 oc bracing. BOT CHORD 2 X 4 SYP SS 'Except! B2 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.2 REACTIONS (Ib/s¢e) 18=1530/0-8-0, 12=1530/0-8.0 Max Horz 18=117(load case 5) Max UpliR18--488(load case 5), 12=488(load case 6) FORCES (lb) -Maximum CompressionlMaximum Tension TOP CHORD 1-2=2085/513, 2-3=2454/695, 3-0=-2264/637, 45=2133/639, 5-6=17981535, Cr7=1798/535, 7$=2133/639, &9=2264/638, 9-10=2454/697, 10-11=2085/513 BOT CHORD 1-18-54412136, 17-18=-662/2136, 16-17=-536/2013;.15-16=53612013, 1415=-419/2013, 13-14=-419/2013, 12-13-54512136, 11-12=545/2136 - WEBS 3-17=133/153, 5.17=13/243, 5.15=-605/292, 6-15=251/969, 7-15=-6051292, 7-13=14/243, 9-13=133/153, 2-18=-10231424, 10-12-1023/424 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.0psf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load rwnconcurtent with any other live loads. -• 4) Al plates are 3x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 488 lb uplift at joint 18 and 488 lb uplift at joint 12. LOAD CASE(S) Standard L A WARNING -Verify design parameters and READ NOTES ON TSI3 AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 - is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component N Safety Information available from Truss Plate Institute 583 D'Onofrio Drive, Madison, WI 53719. O Job Truss Truss Type Qty Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property -01 14-j3/q *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated.. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack on inadequately braced trusses. c,-z 0 caq4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate ZC23materials o � other interested parties. plates 0 - 1/16" from outside o_ �a6 M4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-ece-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4X 4perpendicular to slots. Second Is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings tl�w 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16, Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek® DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, , Guide to Good Practice for Handling, ,Installing & Bracing of Metal Plate ® © 2004 Mitek® 'Connected Wood Trusses. Job Truss Taus Type ay Ply Centex Homes, Model 2227 A X06-003 B02 HIP 2 1 Job Reference (optional) Unive"FOrW Product, Inc. E359, FL Pierce, Fl. 34946, James L. Shoaf 6.300 s Dec 12005 MTek Industries. Inc. Wed Jan 31 14: 07 Page 1 7-4-11 , 15-0-0 19-0-0 26-7-5 34-0-0 , � 7-4-11 7-7-5 4 Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/a *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 0-'/Ib" 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-2 c2-s materials on inadequately braced trusses. 0 03 4 WEBS 3. Provide copies of this truss design to the building om designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate FP �, �,� 3 ��' 3 0 other interested parties. 0 -/ie" from outside a 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-8 csa ce s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTeke DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate • © 2004 IVIRW 'Connected Wood Trusses. V\ /\,J VW\,J O Job Truss Truss Type aY Ply Centex Homes, Model 2227 A ' X06-003 B03 HIP 1 1 Job Reference Symbols PLATE LOCATION AND ORIENTATION 13/,q *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 X O * For 4 x 2 orientation, locate M: plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4. perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSII: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1, Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII . 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14, Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise, © 2004 Mitek® Truss Type Qty Ply Centex Homes, Model 2227 A XO6-003 803A SPECIAL 1 1 Job Reference o tonal Unive"FeMst Product Inc. E359, FL Pierce, R. 34946, James L. Shoat 6.300 s Dec 1 2005 MITek krdustries, Inc. Wed Jan 31 14:2 7 Page 1 6-3-5 13-0-0 21-0-0 25-7-12 29-8-12 , 31-0-8 , 34-0-0 , , r , 6-3-5 6-8-11 840-0 4-7-12 4-1-0 1-9-12 2-5-8 Scale =1:57. 5x10 MT19H_ Sub q 5 5.00 12 W4 6 3 1 7 1.5x4 II W6 8 4x6 a W3 y 2 yy 10 iqq 1 11 I4 6x10 = 5x10 I$ '- a 3x6 = 22 21 ZO 19 18 17 14 13 12 3x6 11 46 = Sx8 = 2x5 11 3x5 II 3x6 II 0-0-0 0 34-0-0 1-0-9 6-3-5 13-0-0 21-0-0 25-7-12 29-8-12 , 31-6$ ,33-0-0, , � 1-0-0 5-3-5 6-8-11 840-0 4-7-12 4-1-0 1-9-12 1-5-8 1-0-0 Plate Offsets X :a1$0-1$ 9:0-2-40-2-0 12:a3-Oo-0-1 1s:o-3-1z,a2$ 16:0-3-00-2-1 22:0-1-110-1-0 LOADING (psf) SPACING 2.0-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 1.00 Vert(LL) -0.22 20-21 >999 360 MT20 244/190 TCDt, 15.0 Lumber Increase 1.25 BC 0.85 Vert(TL) -0.67 20.21 >563 180 MT78H 244l190 BCLL" 10.0 Rep Stress Ina YES WB 0.57 Horz(TL) 0.22 12 Na Na BCDL 10.0 Code FBC2004lTPI2002 (Matrix) Weight 165 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 'Except' TOP CHORD Structural wood sheathing directly applied. T2 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-0-8 oc bracing. BOT CHORD 2 X 4 SYP No.2'ExcepY WEBS 1 Row at midpt 4-18 81 2 X 4 SYP SS WEBS 2 X 4 SYP No.2 REACTIONS (Ib/size) 22=1530/0$-0, 12=1530/0-8-0 Max Haz22=90(load case 5) Max UpIift22--456(load case 5),12=456(load case 6) FORCES (lb) -Maximum Compression/Maximum Tension TOP CHORD 1-2=2113/483, 2-3=2401/604, 3-4=-2189/612, 45=1943/601, 5-6=31921860, 6-7=$287/838, 7$=-4673/1133, 8-9=-440211057, 9-10=1243/314, 10-11=993/237 BOT CHORD 1-22--480/2106, 21-22=561/2106, 20-21=561/2106, 19-20--43011982, 18-19=-430/1982, 17-18--54/206, 16-17=0177, 6-16=126/140, 15-16=79713461, 1415=-56/253, 8-15=174/95, 13-14=113/457, 12-13=-2251981, 11-12=2251981 WEBS 3-21=105(92, 3-20=178l182, 4-20=33/393, 418=203/133, 5-18=-306/139, 16-18=377/1783, 5-16=-421/1374, 7-16=573/191, 13-15=130/612, 9-15=712/3072, 9-13=10451259, 7-15=25511074, 2-22=808Y300, 10-12=724/228 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 3x4 MT20 unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 456 Ib uplift at joint 22 and 4561b uplift at joint 12. LOAD CASE(S) Standard A WARNING - Verijy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MlTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 - is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component � Safetv Information available -from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. O Job Truss Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. O * For 4 x 2 orientation, locate plates 0 - 1/0 from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4, Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6, Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12, Top chords must be sheathed or puriins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior 16. approval of a professional engineer. Install and load vertically unless indicated otherwise. MiTek® m • © 2004 Mitek® Homes, Model 2227 A X06-003 804 HIP 1 1 Job Reference c tlonal Univers�st Product, Inc. E359, FL Pierce, Fl. 34946, James L Shoat 6.300 s Dec 1 2005 MTek Industries, Inc. Wed Jan 31 14:2 07 Page 1 , 5-6-4 , 11-0-0 17-0-0 23-0-0 , 28-5-12 34-0-0 J 5-6-4 5-5-12 6-0-0 6-0-0 5-5-12 5-6� Scale= 1:57.1 6x8 6x8 = 4 5 6 5.00 12 IVI 3 W2 W 7 3 W 2 8 1 9 I$ 3xs m 16 15 14 13 12 11 10 3x6 4 4x6 = 3x8 = 4x6 = 3x8 11 3x8 II DD1-4-0 0 O Jab Truss Truss Type �' Ply Centex 0-0-0 3 -0 Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. O *For 4 x 2 orientation, locate v plates 0 - 1/16" from outside edge of truss, *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20120 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Cobstruction. DSB-89: Design Standard for Bracing. BCSII : Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate 'Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 0 TEELOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII I. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses, 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Homes, Model 2227 A X06-003 B04A SPECIAL 1 1 Job Reference o tional Univers®L[Vst Product, Inc. E359, FL Pierce, Fl. 34946, James L Shoaf 6.300 s Dec 1 2005 M7ek Industries, Inc. Wed Jan 31 14:2 7 Page 1 , 5-6-4 11-0-0 17-0-0 23-0-0 25-7-12 27-6-4 , 29-8-12 , 31-0-8, 34-0-0 , 5-0-4 5-rr12 6-0-0 6-0-0 2-7-12 2-0-8 2-0-8 1-9-12 2-5-8 Scale =1:56. 6x8 5x8 = - 4 5 6 5.00 12 O O Job Truss Truss Type Qh' Ply Centex >*4X16 Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property - 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 0 -'/74, 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-2 materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 Pr designer, erection supervisor, property owner and all For 4 x 2 orientation, locate �,3other [2M2 interested parties. plates 0 - /�a" from outside �4. Cut members to bear tightly against each other. edge of truss.5. Place plates on each face of truss at each joint and c7-e embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPII I. _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated, ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 MiteV Connected Wood Trusses. Job Tnus Truss Type Oty Ply Centex Homes, Model 2227 A X06-003 605 HIP 1 1 Job Reference o tlonal Univers®L[p�st Product, Inc. E359, Ft. Pierce, Fl. 34946, James L Shoat 6.300 s Dec 1 2005 MTek Industries, Inc. Wed Jan 31 14:2ffl 07 Pagel 5-8-11 9-0-0 142-0 19-10-1 25-0-0 28-3-5 34-0-0 , 5-8-11 3-3-5 5-2-0 5-8-1 5-2-ERI 0 3-3-5 5-8-11 Scale=1:57.1 4x6 = 4x6 = 5.00 12 4 5 6 7 3 b 1 W W2 4 W 2 9 1 1 0 I$ axt; a 17 16 15 14 13 12 11 3x6 4 3x8 = 5x10 N(T18H WB= 5x10 MT1aH W6= 3x8= 3x8 I I axe IIt) 0-0 0-0 1-0-9-17-25-0-0 33-0-0 34-0-0 1-0-0 8-0-0 8-0-0 8-0-0 8-0-0 Plate Offsets 1:0�-0 o-1-s a:o�s o-0-2 10:0.3-0 o-1-a 11:0.0-00.0-0 17:0-0-12 a1-a LOADING (psi) SPACING 2-0.0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.82 Vert(LL) -0.26 12-14 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25. BC 0.98 _ Vert(TL) -0.78 12-14 >485 180 MT18H 244/190 LL BC10.0 Rep Stress Irxr YES WB 0.52 Horz(TL) 0.13 11 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 158 lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS'Except TOP CHORD Structural wood sheathing directly applied or 2-9-5 ac purliru. T2 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2 X 4 SYP No.1 'Except B22X4SYP No.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 17=1530/0.8-0, 11=1530/0-8-0 Max Horz17=-62(load case 6) Max Upliftl7=-457(load case 3), 11=-457(load case 4) FORCES (lb) -Maximum CompressionlMaximum Tension TOP CHORD 1-2=1984/535, 2-3=23841701, 3-4=2349/717, 45=2191f700, 5-0=28971928, 6-7=21911700, 7.8=-2349f717, 8.9=23841701, 9-10=1984l535 BOT CHORD 1-17=563/2054, 16-17=566/2054, 15-16=816/2819, 14-15=-816/2819, 1&14=�14/2819, 12-13=814I2619, 11-12=563/2054, WEBS 3-16=19/261, 4-16=100/484, 5.16--853/307, 5-14=0/218, 6-14--01218, 6-12=853/307, 7-12=100/484, &12=-19/261, 2-17=1102/403, 9-11=1102l403 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed fora 10.0 psf bottom chord live load norx:onarrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 3x4 MT20 unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 457 lb uplift at joint 17 and 457 lb uplift at joint 11. LOAD CASE(S) Standard e WARNING - Verdesign parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. ijy 14515 N. Outer Forty, Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/a *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z cz-3 materials on inadequately braced trusses. WEBS oa, 4 3. Provide copies of this truss design to the building O designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate m o o �,,, �� 3 other interested parties. plates 0 - Vie' from outside o �� U 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c�-a csa cs-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII , 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text In the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design, if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal - Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. BCSI l : Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate / © 2004 MiteO Connected Wood Trusses. V\/\\1�®a Job Truss Truss Type Ply Centex Homes, Model 2227 A X06-003 B06 HIP 71- 2 Job Reference o tional Univers t Product Inc. E359, FL Pierce, R. 34946, James L Shoaf 6.300 Is Dec 1 2005 MTek Industries, Inc. Wed Jan 31 14:271 Page 1 4-7-4 7-0-0 11-7-15 17-M 22-4-1 274)-0 29�+ 344)-0 , � 4-7-4 2-4-12 4-7-15 5-4-1 5-4-•1 4-7-15 24-12 4-7-4 Scale =1:56. 5x7 - 5x7 = S_ 5.00 12 4 19 20 5 21 22 6 23 24 7 25 26 8 3 9 IV IVW2V I I IV 2 10 4 1 11 j$ 46 = 18 27 17 28 16 29 30 15 31 32 14 33 13 34 12 4x6 = 5x7 4x6 = 3x5 = US = Us = 4x6 = 5x7 0-M 0-M 1-0 Q 7-M 11-7-15 17-0-0 224-1 274)-0 33-0-0 34-0-0 1-0-0 6-" 4-7-15 54-1 5-4-1 4-7-15 6-M 1-0-0 Plate Offsets 1:0-4-2 0-2 4:0-5-40-2-1 6:0.2-8 0-3-0 8:0-5-40-2-1 . 11:0-4-2 0-2-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20'0 Plates Irxreas , 1.25 TC 0.38 Vert(LL) 0.28 15 >999 360 MT20 244/190 TCDL 15.0 _ Lumber Increase 1.25 BC 0.76 Vert(TL) -0.72 15-16 >553 180 BCLL 10.0 Rep Stress Ina NO WB 0.22 Horz(TL) 0.18 11 n/a We BCDL 10.0 Code FBC2004RPI2002 (Matrix) Weight: 347 lb LUMBER BRACING TOP CHORD 2 X 4 SYP Not TOP CHORD Structural wood sheathing directly applied or 4-4-15 oc purlins. BOT CHORD 2 X 4 SYP Not BOT CHORD Rigid ceiling directly applied or 8-" oc bracing. WEBS 2 X 4 SYP No.2 SLIDER Left 2 X 6 SYP SS 2-0-11, Right 2 X 6 SYP SS 2-0-11 REACTIONS (lb/size) 1=2687/0-", 11=2687/0-8-0 Max Horz 1 =41Woadl case 6) Max Uplift1=9010oad case4), 11=901(load case 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=5935/2044, 2-0=5866/2049, 3-4=-W9l/2086, 4-19=7457/2709, 19-20=7456/2709, 5-20=7456/2709, 5-21=-8269/3007, 21-22=-8269/3007, 6-22--8269/3007, 6.23=-8269/3007, 23-24=-8269/3007, 7-24=8269/3007, 7-25=7456/2709, 25-26=7456/2709, 8-26=7457/2709, 8-9=5891/2086. 9-10=WW2049, 10-11=5935/2044 BOT CHORD 1-18=1818/5330, 18-27=1864/5470, 17-27=1864/5470, 17-28=1864/5470, 16-28=1864/5470, 16-29=2612f7456, 29-30=-2612/7456, 15-30=-2612f7456, 15-31=2610f7456, 31-32=2610/7456, %32=2610/7456, 14-33=186215470, 13-33=186215470,1334=1862/5470, 12-34=1862/5470,11-12=1816/5330 WEBS 3-18=-58/293, 4-18=78/483, 4-16=888/2406, 5-16=-1078/501, 5-15=342/984, 6-15=-674/368, 7-15=-342/984, 7-14=10781501. 8-14=-888(2406, 8-12=78/483, 9-12=58/293 NOTES. 1) 2-ply truss to be connected together with 10d (0.1315r3") nails as follows: Top chords connected as follows: 2 X 4 -1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 4 -1 raw at 0-9-0 oc. Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads rioted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 5) Provide adequate drainage to prevent water ponding: 6) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All plates are 3x4 MT20 unless otherwise indicated. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 901 lb uplift at joint 1 and 901 lb uplift at joint 11. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)158 lb down and 121 lb up at 7-0-0, 104 lb down and 75 Ib up at 9-0-12, 104 Ib down and 75Ib up at 114)-12, 104 lb down and 75Ib up at 13-0-12, 104 lb down and 75 lb up at 15-0-12, 104 lb down and 75 lb up at 17-0-12, 104 lb down and 75 lb up at 18-11-4, 104 lb down and 75 lb up at 20-114, 104 Ib down and 75Ib up at 22-11-4, and 1041b down and 75 Ib up at 24-11-4, and 158 lb down and 121 lb up at 27-" on top chord, and 364 lb down and 104 lb up at 7-0-0, 64 lb down at 9-0-12, 64 lb down at 11-0-12, 64 lb down at 13-0-12, 64 lb down at 15-0-12, 64 lb down at 17-0-12, 64 lb down at 18-114, 64 lb down at 20-11-4, 64 lb down at 22-11-4, and 64 lb down at 24-11-4, and 364 lb down and 104 lb up at 26-11-4 on bottom chord. The designlselection of such connection device(s) is the responsibility of others. 1) 1 arlGrEd6E� Ord READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. w h M.M11 This 14515 N. Outer Forty, Suite #300 O U use only el cfors. design is based only upon parameters shown, and is for an Individual building component. Appl (_y� i K ter7639cliR�r Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for la era support of in iv dual web mem ers only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector, Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB49 and BCSII Building Component ° contin%7kWd fftion available from Truss Plate Institute, 583 D'Onofrlc Drive, Madison, WI 53719. M iTe Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/a *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths, Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z cza materials on inadequately braced trusses. WEBS 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all For 4 x 2 orientation, locate Ac, �,3 �,�' other interested parties. plates 0 - 1/16" from outside O n- U4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-e csa ce-6 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1, * Plate location details available in Welk 20/20 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second Is to camber for dead load deflection. dimension is the length parallel 10, Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, IRW7@1 Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. B06 IHIP 1' I 2 )AD CASE(S) Standard Concentrated Loads (lb) Vert: 4=158(8) 8=158(B)18=-364(B)15=44(B) 6=104(B)12=364(13)19-104(1121) 201 104(B) 21=104(B) 22=104(B) 23=104(B) 24=104(B) 25=104(B) 26=104(B) 27=44(B) 28=-44(B) 29 "B) 30=44(B) 31=-"B) 32=-44(B) 33=-44(B) 34=44(B) 0 WARNING - VerWjy design parameters and READ NOTES ON TRIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely Seat. or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. c,-2 C2-3 WEBS c3� 4 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate �,� i,3� 3 O other interested parties. pcc lates 0 - 1 /16" from outside n. �A� 1 U 4. Cut members to bear tightly against each other. edge of truss. a 5. Place plates on each face of truss at each joint and c7-8 csa cs-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 199b at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the . The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior EV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Wek" Connected Wood Trusses. Job Truss Type aty Ply Centex Homes, Model 2227 A IT-- X06-003 B08 SPECIAL 1 1 Reference Job Reference o floral ( ptlon Universal Product, Inc. F_359, FL Pierce, Ft. 34946. James L Shoat 6.30J s Dec 1 Industries, Inc. Wed Jan 31 114:04SQ007 Page 1 , 6-8-11 9-M 144-0 19-8-0 224-0 28-2-13 34-0-0 5-8-11 3-3-5 54-0 54-0 2-8-0 5-10-13 5-9-3 Scale = 1:58.1 6x6 = 5x8 = 7 Us= 5.00 MY 4 5 6 3 w 2 8 4 IVI 4 7 2 9 1 .10 _ i$ 3X6 _ 18 17 16 15 14 13 12 11 3X6 % 4x6 = 5X8 = 4x6 = 34 11 ._ 3x7 11 1DD� 0-0-0 1 A" 9-0-0 14 -0 19-8-0 26-2-6 32-8-0 3"-0 , 1-0-0 7-8-0 5-4-0 5.4-0 6-" 6-5-10 0-4-0 0-" 1-0-0 Plate Offsets X 1:0-3-0 0-15 4:0.5-40.2-0 6:0-2-8 0-2-011:0-3-00-0- 18:0-3-12 04-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.80 VwgLL) -0.2612-14 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.77 12-14 >489 180.. BCLL 10.0 Rep Stress Incr YES WB 0.33 Horz(TL) 0.12 11 Na n/a _ BCDL 10.0 Code FBC2004RPI2002 (Matra) Weight: 166lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS'Except' TOP CHORD Structural wood sheathing directly applied or 2-10-9 oc pudins. T2 2 X 4 SYP Not, T3 2 X 4 SYP No.2 BOT CHORD Rigid calling directly applied or 6-10-14 oc bracing. BOT CHORD 2 X 4 SYP SS -Except B2 2 X 4 SYP No.2 WEBS 2 X 4 SYP Not REACTIONS (lb(s¢e) 18=1530/0-8.0, 11=1530/0-8-0 Max Horzl8=81(load case 5) Max Upliftl8=-031(load case 5). 11=443(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1993/558, 2-3=23811758, 3.4=2338f148, 4-5=2863/936, 5-Cr--2845/875, 6-7=3131/991, 7-8=2278/638, 8-9=2441/638, 9-10=2089/511 - BOT CHORD 1-18=596/2055, 17-18=677/2055, 16-17=-042/2160, 15-16=-642/2160, 14-15=-846/2863,13.14=509/2013,12-13=509/2013, 11-12=523/2128, 10-11=523/2128 WEBS 3-17=10/159, 4-17=-39/115, 415=276/862, 5-15=-378/175, 5.14=132/106, 6-14=1370/498, 7-14=593/1777, 7-12=59/191, 8-12=164/169, 2-18=-10721470. 9-11=9821347 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonrconcunent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical -connection (by others) of truss to bearing plate capable of withstanding 531.lb uplift at joint 18 and 443 lb uplift atjoint 11. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MfTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult AN51/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe Safety Information available from Truss Plate Institute, 683 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a * Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPl1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate .Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o- 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MitelV O Job Truss Truss Type City -Ply Centex Homes, Model 2227 A X06-003 B09 'SPECIAL 1 1 Job Reference (optional) Universal 60"Product, Inc. E359, FL pierce, Fl. 34946, James L Shoat 6.300 s Dec 1 2005MiTek Industries, Inc. Wed Jan 31 14:27 7 Page 1 , 4-1-2 7-0-0 11-74 14-7-10 17-8-0 224-0 26-10-6 30-4-1 34-0-0 , � 4-1-2 2-10-14 4-7-4 3-0-6 3-0-0 4-8 Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. oC O *For 4 x 2 orientation, locate v plates 0 -'/16" from outside a edge of truss. *This symbol indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 ®General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. .Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. O_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane atjoint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE .AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS'ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified, by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, ,q• �a Installing & Bracing of Metal Plate ©2004 Mitek® Connected Wood Trusses. R Job Truss Truss Type City Ply Centex Homes, Model 2227 A X06-003 C01 COMMON 3 1 Job Reference (optional) Universal FylgSbProduct. Inc. E359, FL Pierce, Fl. 34946, James L. Shoat 6.300 s Dec 12005 MTek Industries, Inc. Wed Jan 31 14:27:20 200 1 5-9-6 11-8-0 17-6-11 224-0 , 5-9-6 5-10-10 5-10-11 4-9-5 Scale = 1:36. 46 = 4 5.00 12 W W1 5 3 6 2 7 1 ERE 4x6 C st 10 9 8 5x7 II 3x6 11 3x6 = 1 4 0 0-0-0 1-0$44 7-9-11 15.6-6 22-4-0 , 1-0-0 65-11 7-8-11 6-9-10 04-0 Plate Offsets 1:0-144 0-0-2 , 5:0-1-0 0-4 :04-8 0-2-1 11:0 1-110 0 8 LOADING (psf) SPACING 2-M CSI DEFL in poc) Udell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.94 Vert(LL) -0.12 8-10 >999 360 MT20 244/1190 TCDL 15.0 Lumber Increase 1.25 BC 0.90 Vert(IL) -0.40 8-10 >637 180 BCLL 10.0 ' Rep Stress Ina YES WB 0.08 HorAn) 0.05 7 n/a Na , BCDL 10.0 Cade FBC20041rP12002 (Matrix) Weight 103lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 9-7-8 oc tracing. WEBS 2X4SYP No.2 SLIDER Right 2 X 6 SYP SS 2-6-12 REACTIONS (lb/sae) 7=941/0-8-0, 11=106910-8-0 Max Horz11=81(load case 5) Max Upli117=268(load case 6), 11=355(load case 5) FORCES (lb) - Maximum CompressionfMaximum Tension TOP CHORD 1-2=1305/305, 2-3=1546/435, 3-4=1352/393, 4-5=-1480/438, 5-6=1618/485, 6-7=1697/475 BOT CHORD 1-11=319/1330, 10-11=-000/1330, 9-10=221/1044, 8-9=221/1044, 7-8=370H453 WEBS 3-10=231/186, 4-10---88/332, 4-8=140/454, 5-8=267/203, 2-11=701/292 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 3x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 268lb uplift at joint 7 and 355 lb uplift at joint 11. LOAD CASE(S) Standard A WARNING - Ver(N design paramertem and READ NOTES ON THIS AND REVERSE SIDE BEFORE 08E. 14515 N. Outer Forty, 0 Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite N300 . Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCS11 Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 -yid' *For 4 x 2 orientation, locate plates 0 -1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4. X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1 National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89:- Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury I . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and OP embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1, 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. 0 2004 Mitek® Job Truss Truss Type Oty Ply Centex 0 0 Homes, Model 2227 A X06-003 CO2 COMMON 2 1 Job Reference Symbols Numbering System &General Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property t3/a *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated, 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and and securely seat. or X-bracing, is always required. See BCSI1. 0-1/0 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-2 c2.3 materials on inadequately braced trusses. WEBS c3� 4 3. Provide copies of this truss design to the building Cc designer, erection supervisor, property owner and all * 4 x 2 orientation, locate �,� 3 ��a 19 � other interested parties. Plates plates 0 - /ia" from Outside O yaw a = 4. Cut members to bear tightly against each other. edge of truss. o " C) 5. Place plates on each face of truss at each joint and c7-e csa ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6, Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII . 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber, PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate 2004 MiteV Connected Wood Trusses. Job Truss Truss Type Qty Ply Centex Homes, Model 2227 A X06-003 CO3 ]HIP 1 1 Job Reference optional) UniversalProducL Inc. E359, FL Pierce, Fl. 46, James L. Shoal 6.300 s Dec 1 2005 tuiTek Industries, Inc. Wed Jan 31 14:2 . 7 Page 1 349 5-6 4 11-" 124-0 , 17-9-12 234-0 5-6-4 5-5-12 1-4-0 5-5-12 5-6-4 4 Scale = 1:38. 4x6 = 46 = 4 5 5.00<3- 6 PT fvEl: W 2 7 1 6 132 12 11 10 3x6 11 3x6 = 3x6 11 14-0 0_020 " - L-0 11-0-0 12 4-0, 22-M 1-0-0 9-8-0 14-0 9-8-0 04-0 04-0 1-" Plate Offsets 4:0-3-0 0-245:0.3-00-249:0-3-00-0-1 13:0-1-110-0-8 LOADING (pst) SPACING 2-" CSI DEFL in (loc) Well L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.90 VwXLL) -0.14 9-11 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.90 Vert(TL) -0.38 12-13 >657 180 BCLL 10.0 Rep Stresslncr YES WB 0.17 Horz(TL) 0.05 9 n/a rda BCDL 10.0 Code FBC20041fP12002 (Matra) Weight: 104 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid calling directly applied or 9-8-12 oc tracing. WEBS 2 X 4 SYP No.2 REACTIONS (Ih/size) 13=1050/0-8.0, 9=1050/0.8-0 Max Horc13=76(load case 5) Max Upliftl3=347(load case 5), 9=347(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1259/288, 2-3=-1489/435, 3-0=1201/315, 4-5=1071/324, 5-6=1201/315, 6 7=1490/435, 7$=-1259/288 BOT CHORD 1-13=-317/1281, 12-13=393/1281, 11-12=193/1071, 10-11=317/1281, 9-10=317/1281, 8-9=317/1281 WEBS 3-12=-288/214, 4-12-41/232, 5-11=.41/232, 6-11=288/215, 2-13=675/339, 7-9=-675/338 z NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS: cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nlonconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated.- 6) Provide mechanical connection (by others) of buss to bearing plate capable of withstanding 347 lb uplift at joint 13 and 347 lb uplift at joint 9. LOAD CASE(S) Standard e WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE BIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MfTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M MeSafety Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/q *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. and or X-bracing, is always required. See BCSI1. 0-1/0 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z cz-a materials on inadequately braced trusses. '*For WEBS c3� 4 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all 4 x 2 orientation, locate op �,� 3 �,�' 3 0 other interested parties. plates 0 - 1/16" from outside o yaw U 4. Cut members to bear tightly against each other. edge of truss. 5• Place plates on each face of truss at each joint and c7-8 cea ce s embed fully. Knots and wane at joint locations are BOTTOM CHORDS *This symbol indicates the regulated byANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1 • 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11 • Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted, BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15• Do not cut or alter truss member or plate without prior EV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, / Installing & Bracing of Metal Plate © 2004 Mitek® .'onnected Wood Trusses, A Job Truss Truss Type Oty Ply Centex Homes, Model 2227 A • X06-003 C04 HIP 1 1 Job Reference (optional) Universal bQ"Producl, Inc. E359, Ft. Pierce, Ft. 34946. James L Shoal 6.300 s Dec 12005 MiTek Industries, Inc. Wed Jan 31 14:22AEPA67 Page 1 4-5-2 9-M 144-0 1 &10-14 2 34-0 , 4-5-2 4-6-14 54-0 4-6-14 4-5-2 Scale = 1:38. 5x8 = 4x6 = 4 5 1-7 5.00 12 W1 6 3 3 W 7 2 8 1 11 10 3x6 II 5x12 = 3x6 11 1-4-0 22 1-0�-0 9-0-0 144-0 22-M 1-0-0 7-8-0 54-0 7-" 04-0 04-0 1-" Plate Offsets X 1:0-3-00-1-8 4:0-5.12 0-2-8 8:0.3-00.1-8, 9:03-00-0 8. 10:0-4-4 0-3-012:0-1-11 0.0-1 LOADING (psf) SPACING 2-M CSI DEFL in (loc) I/detl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.95 Vert(LL) -0.12 10-11 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.73 Vert(M) -0.29 10-11 >857 180 BCLL 10.0 Rep Stress Ina YES WB 0.07 Horz(TL) 0.05 9 n/a n!a BCDL 10.0 Code FBC2004rFP12002. (Matrix) Weight. 107lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-11-14 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 12=1050/0-8.0, 9=10501050 Max Horz12=62(load case 5) Max Upliftl2--331(Icad case 5), 9=331(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1161/267, 2-3=1426/385, 3-0=13421372, 45=1217/376, 5Z--1343/372, 6-7=1426/385, 7-8=1161/267 BOT CHORD 1-12=288/1204,11-12=337/1204, 10-11=253/1217, 9-10=288/1204, 8-9=28811204 WEBS 3-11=14/132, 4-11=0/211, 4-10=106/107, 5-10=21211, 6-10=14/133, 2-12=764/327, 7-9=765/326 NOTES 1) Unbalanced roof live loads have been considered for this design. - 2) Wind: ASCE 7-02;130mph (3-second gust); h=20R; TCDL=4.2ps ,, BCDL=3.0psf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 331 lb uplift atjoint 12 and 331 lb uplift at joint 9. LOAD CASE(S) Standard A WARNING - Verifg design parameters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates, * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots, Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated, BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: , Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 Ir O U a O R Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS . 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2, Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 1L 5, Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1, 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty, Ply Centex Homes, Model 2227 A X06-003 C05 HIP 1 1 Job Reference (optional) Universal 6a" Product, Inc. E359, Ft. Pierce, R. 34946, James L Shoaf 6.300 s Dec 1 2005 MTek IndusMes, Inc. Wed Jan 31 14 2007 Page 1 'r 45-15 7-0-0 11-8-0 164-0 18-10-1 23-4-0 , 45-15 2-0-1 48-0 48 Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 0 la. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z cz-3 materials on inadequately braced trusses. p * g 4 WEBS 0 3. Provide copies of this truss design to the building o o designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate m � � �,3 �'� 3 °C other interested parties. p plates 0 - 1/16" from outside O a. !V U 4. Cut members to bear tightly against each other. edge of truss. Pi 5. Place plates on each face of truss at each joint and c7-8 cea ce-6 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated byANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10, Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12, Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. �Su (supports) occur, Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 01 16. Install and load vertically unless indicated otherwise. ��� .Industry Standards: El ANSI/TPI1: National Design Specification for Metal - Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ©2004 Mitek® Connected Wood Trusses. Job Truss Truss Type Qty Ply n x omen, Model 2227 A X06-003 CAMONO TRUSS 4 1 Job Reference (optional) Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L Shoaf 6.300 1 2005 MTek Industries, Inc. Wed Jan 31 14:27:22 2007 Page 1 1 Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 0-1/0and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1, 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff, spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job TrussTypeQty Ply Homes, Model 2227 A X06-003 FCASE MONO TRUSS 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946. James L. Shoaf 2 6.3C@-VW 12005 MTek Industries, Inc. Wed Jan 31 14:27.,23 2007 Page 1 1-0-0 1-0-0 5.00 F12 scale =1:4. 1 ' SIMOSON Ti MTS 16 XN 3x4 = 3 0-4-10 0-0-0 1-0-0 1-0-0 Plate Offsets 1:0-0-0 0.0-0 LOADING (psi) SPACING 2-" CSI DEFL in (loc) Udell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 VergLL) -0.00 1 rdr 180 MT20 . 2441190 TCDL 15.0 Lumber Increase 1.25 BC '0.02 Vert(TL) -0.00 1 rdr 90 BCLL 10.0 ' Rep Stress Ina YES WB 0.00 Horz(TL) 0.00 n/a nda BCDL 10.0 Code FBC20041TPI2002 (Matrix) Weight: 3 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 140.0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-" oc bracing. REACTIONS (Ib/size) 3=101Mechan'ical, 2=79/Mechanical Max Horz3=98(load case 1), 2-98(load case 1) Max UpIM-- 4(Ioad case 3), 2=50(load case 5) Max Grav3=20(load case 2), 2=79(load case 1) FORCES (lb) - Maximum CompressioWaximum Tension TOP CHORD 1-2=-80/119 BOT CHORD 1-3=98/82 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.OpsF Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3 and 50 lb uplift at joint 2. 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths , Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1. U -1/16" 1 2 3 TOP CHORDS 2, Never exceed the design loading shown and never stack c1-2 c2-3 materials on inadequately braced trusses. WEBS 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate o I? 3 3 Cc other interested parties. plates 0 - 1 /16" from outside 0 O �A� U 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-e csa c5-6 embed fully Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6, Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate , © 2004 Mitek® connected Wood Trusses. Job Truss TypeCityPlyHomes, Model 2227 A X06-003 Tr-'JlU MONO TRUSS 12 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946, James L Stxiaf 2 6.309mac 12005 MTek Industries, Inc. Wed Jan 31 14:27:23 2007 Page 1 1-0-0 Scale =1:4: 5.00 12 T' SIMPSON MTS16 . 1 . 3xa 3 0-4-10 0-0-0 1-0-0 LOADING (psf) SPACING 24)-0 CSI DEFL in (lot) Udefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) -0.00 1 Nr 180 M7M 244l190 TCDL 15.0 Lumber Increase 1.25 BC 0.02. Vert(m) -0.00 1 Nr 90 BCLL' 10.0 Rep Stresslnrx YES WB 0.00 Horz(TL) 0.00 Na Na BCDL 10.0 Cade FBC2004lTPI2002 (Matrix) Weight 31b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 140-0 oc purliru. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6.0-0 oc bracing. REACTIONS (Ib/s¢e) 3=10MIechan'ical, 2=79/Mechanical Max Horz3=99(load case 1), 2--"load case 1) Max Uplift3=14(load case 3), 2--5((laad case 5) Max Grav3--20(load case 2), 2=79(load case 1) FORCES (lb) -Maximum Compression/Maximum Tension TOP CHORD 1-2--80/120 BOT CHORD 1-3=-99/82 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2p6f BCDL=3.0psF Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; - Lumber DOL=1.60 plate grip DOL=1.60. � 2) 'This truss has been desigried,for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (6y otters) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3 and 50 lb uplift at joint 2. ' 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard e WARNING - Verlfij design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of The erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53779. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. 0 O U i N Numbering System 6-4-8 1 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, properly owner and all other interested parties. O U 4. Cut members to bear tightly against each other. O_ 5. Place plates on each face of truss at each joint and embed fully Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MITek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4. X 4 perpendicular to slots. Second i s to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MITek® DSB-89: Design Standard for Bracing. BCSII : Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Balm © 2004 Mitek® Connected Wood Trusses. V\/\\1�� Job Truss Truss Type Qly Ply Centex Homes, AAodel 2227 A OOFaD 02 X06-003 CJ3 MONO TRUSS 4 1 Job Reference(optional) Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L. Shoaf 0 0-0 6.300 s Dec 1 2005 MTek Industries, Inc. Wed Jan 31 14:27*23 2007 Page 1 3-0-0 2 3-0-0 Scale =1:7. 4.00 12 Tt 1 1 B1 4x4 = 4x6 It 3 001.0-02 04 1-0-0 3-0-0 1-1-1i 1-0-0 0-1-12 1-10-4 Plate Offsets 1:0-2-14 E 1:0-1-4 1-2-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in poc) Well Lid PLATES GRIP TCLL 20.0 Plates Increase 1.25' TC 0.13 Vert(LL) 0.01 1-3 >999 360 MT20 2441190 TCDL 15.0 -Lumber Increase 1.25 BC 0.07 Vert(TL) -0.01 1-3 >999 180 BCLL 10.0 Rep Stress Inrr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matra) Weight 11 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-" oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE Left- 2 X 4 SYP No.2 REACTIONS (lb/size) 2-981Mechanical, 3=28/Mechan'ical, 1=12610-3-8 Max Horz1=45(load case 3) Max UpliR2= 59(load case 3), 3=41(load case 3), 1=-83(load case 3) Max Grav2--98(load case 1), 3=56(load case 2), 1=126(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=27/27 BOT CHORD 1-3=0/0 S. - NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girders) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 59lb uplift at joint 2, 41 lb uplift at joint 3 and 83lb uplift at joint 1. LOAD CASE(S) Standard e WARNING - Verijy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite 4l300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component ° Safety Information available from Truss Plate Institute, 683 D'Onofrio Drive, Madison, WI 53719. Met Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage Or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1, Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 0-'hd 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z c2-s materials on inadequately braced trusses. WEBS c,4 4 3. Provide copies of this truss design to the building cc designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate 3 o other interested parties. plates 0 -1/0 from outside 0 19 U 4. Cut members to bear tightly against each other. edge of truss. °- 5. Place plates on each face of truss at each joint and c7-e csa ce-6 embed fully, Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate. location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements, LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Miteko connected Wood Trusses. Homes, Model 2227 A X06-003 CJ3A MONO TRUSS 2 1 1-2-10 Job Reference 0 O Job Truss Truss Type city Ply Centex (optional) Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L Shoat 6.300 s Dec 1 2005 AifTek IndustM-lD -04-0-0 0 Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Proper/ 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required, See BCSII . 0-7/iv" 11 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. � c1-2 c2-3 o �� 4 WEBS 3. Provide copies of this truss design to the building cc designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate o �3 ��' 3 other interested parties. plates 0 -1/16" from outside o_ �a� � 4. Cut members to bear tightly against each other. edge of truss. o 5. Place plates on each face of truss at each joint and c7-e csa ce-s embed fully. Knots and wane atjoint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in Welk 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4X 4perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol 'shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text In the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft, spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. BCSII : Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. . Job Tnrss Truss Type Qty Ply Centex Homes, Model 2227 A X08-003 CJ3S MONO TRUSS 1 1 1-2-10 Job Reference (optional) Universal Forest Product, Inc. E359, Ft Pierce, Fl. 34946, Jame8J0Ypoaf 6.300 s DeQ.W5 MTek Industries, Inc. Wed Jan 31 14:27:23 2007 Page 1 2-" 3 2-0-0 Scale: 5.00 12 2 T1 1 B1 3x4 4 1-2-10 04 IX0-" �r--3x5 I I 2-" 2-0-0 Plate Offsets 1:0-1.8 0-0-3 LOADING (psf) SPACING 2-0.0 CSI DEFL in (loc) Udefi Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.06 VwKLL) -0.00 1 >999 360 MT20 244/190 TCDL 15.0 Lumber increase 1.25 BC 0.04 Vert(TL) -0.00 1-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 Na n/a BCDL 10.0 Code FBC2004frP12002 (Mahto Weight9lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 104W oc bracing. SLIDER Left 2 X 4 SYP No.21.6r2 REACTIONS (Ibdsize) 1=89/Mechanrcal, 4=20/Mechanical, 3=70/Mechanicai Max Horz 1=57(load case 5) Max Uplift1=12(load case 5), 3=55(load case 5) Max Grav1=89(load case 1), 4=40(load case 2), 3=70(load case 1) FORCES (lb) - Maximum Compressfon/Maximum Tension TOP CHORD 1-2=34/0, 2-3=23/20 BOT CHORD 1-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2)'This truss has been designed for a 10.0 psf bottom chord live load nonooncurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 12 lb uplift at joint 1 and 55 lb uplift at joint 3. LOAD CASE(S) Standard A WARNING - Vertfy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Wei ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 c2-a materials on inadequately braced trusses. WEBS 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate �,� 3 ��' 3 M O other interested parties. plates 0 - 1/16" from outside o dab U 4. Cut members to bear tightly against each other. edge of truss. ° °- 5. Place plates on each face of truss at each joint and c7-e csa cs-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication, software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output, Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16, Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss` Construction. M iTeke DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Jab Job Truss Thus Type Qty My Centex Homes, Model 2227 A CJ3U MONO TRUSS 9 1 41D Job Reference (optional) Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L Stwaf 0-0-0 6.300 s Dec 12005 MTek Industries, Inc. Wed Jan 31 14:27.,236 2007 Page 1 3-0-0 3 3-0-0 Scale: 1.5--1 5.00 /2 3x6 11 2 Ti 1 1 131 3x4 =>< 5 4� 0 -0 1-0-0 , 1-4-0 , 3-0-0 r 1-" 04-0 148-0 Plate Offsets 2:0-1-11 0-0.0 LOADING (psf) SPACING 240-0 CSI DEFL in (loc) Well L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) 0.00 5 >999 360 MT20 244/190 TCDL 15.0 Lumber Irawse 1.25 BC 0.07 Vert(n) 0.00 4.5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 10 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3.0.0 oc purfins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 3=28IMechanical, 4=-6/Mechan'ical, 5=242/0-8.0 Max Horc5=56(load case 5) Max UpIWA--22(load case 5), "load case 1), 5=126(load case 5) Max Grav3=28(load case 1). 4=12(load case 5), 5=242(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=55/33, 2-3=32(6 BOT CHORD 1-5=0/56, 4-5=0/0 WEBS 2-5=165/95 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4:2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girders) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding ding 22 lb uplift atjoint 3, 6 lb uplift at joint 4 and 126lb uplift at joint 5. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MITek connectors, This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 ' is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Bullding Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-1/0 * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss, *This symbol indicates the required direction of slots in connector plates. 0 0 U EL O R Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all pc other interested parties. 0 U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI I, 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MITek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots, Second is to camber for dead load deflection, dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is Installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MITek® DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Job Thus Taus Type oty Ply Centex Homes, Model 2227 A X06-003 CJ5U MONO TRUSS 8 1 Job Reference o tionalW Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946. Jamc"loaf 6.310 s Dec 12005 MTek Industries, Inc. Wed Jan 31 14:27:24 2007 Page 1 5-0-0 3 5-0-0 Scale: 1'=1 5.00 12 T1 2 B1 3x4 = 4 2M 0-0-0 3x611 1-0-0 1-4-0 , 5-0-0 , 1-" 0-4-0 3-8-0 Plate Offsets 5:0-1-11 0-U-0 LOADING (psf) SPACING 240-0 CSI DEFL in (loc) Udell L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.15 Vert(LL) -0.01 4-5>999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.09 Vert(TL) -0.01 45 >999 180 BCLL 10.0 Rep Stress Inrr YES WB 0.02 Horz(TL) -0.01 3 n/a We BCDL 10.0 Code FBC20041rP12002 (Matron) Weigh 16lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Shwtural wood sheathing directly applied or 5.0-0 oc pudirrs. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid calling directly applied or 10-0-0 oc bracing. WEBS 2X4SYP No.2 REACTIONS (Ib/s¢e) 3=106/Mechanical, 4=34/Mechan'ical, 5=304/0-8-0 Max Horz5=94(load case 5) Max Uplift3=-70(load case 5), 5=-131(load case 5) Max Grav3=106(load case 1), 4=62(load case 2), 5=304(load case 1) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=101/40, 2-3=56/31 BOT CHORD 1-5=-0/94, 4-5=0/0 WEBS 2-5=246/149 NOTES 1) Wind: ASCE 7-02;130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconwrrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 3 and 131 lb uplift at joint 5. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Wei. ° Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/, *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSII . 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack C,-z Cz-3 materials on inadequately braced trusses. 0 WEBS o 4 3. Provide copies of this truss design to the building O designer, erection supervisor, property owner and all For 4 x 2 orientation, locate °° 1 v �,�� 3 o other interested parties. plates 0 -/1s" from outside o �a� U 4, Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and C7-8 Csa C5-5 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6, Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. • Job Thus Truss Type Oty Ply Centex Homes, Model 2227 A XO6-003 D01 COMMON 1 1 Job Reference (optional) Universal Forest Prel"tnc. E359, FL Pierce, Fl. 34946, James L Shoaf 6.300 s Dec 1 2005 MiTek Industries, Inc. Wed Jan 31 1427:24 2007 Page 1 6-2-0 114-0 , 6-2-0 5-2-0 . Scale=1:18. 4x6 = 3 5.00 12 4 W 1 T2 T1 2 2 5 1 1311 6 3x6 II 3&d1-0 0-M 1-0-0 1-4 114-0 , 1-0-0 0-4-6 10-0-0 Plate Offsets 1:0-1-14 0.0, 5:0-0-4 0-0.3 :0-1-11 0-0-0 LOADING (psi) SPACING 2-" CSI DEFL in (loc) Wall L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.39 Vert(LL) -0.02 5-6 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.34 Vert(TL) -0.06 5-6 >999 180 BCLL 10.0 Rep Stress [nor YES WB 0.04 Horz(TL) 0.01 5 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (MabtK) Weight: 441b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. . WEBS 2X4SYP No.2 SLIDER Right 2 X 4 SYP No.2 2-95 REACTIONS (lb/size) 5=442 Mechanical, 7=5781043.0 Max Horz7=43(load case 5) Max Uplifts=126(load case 6). 7=218(load case 5) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=-450/101, 2-3=-569/164, 3-=-096/148, 4-5=574/135 BOT CHORD 1-7=100/457, 6-7=86/457, 5Z=-W457 WEBS 3-6=01179, 2-7=3991221 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psF, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip OOL=1.60. 3) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Al plates are 3x4 MT20 unless otherwise indicated. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 126 Ito uplift at joint 5 and 218 lb uplift atjoint 7. LOAD CASE(S) Standard i A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-'/0 * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 O U Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 Ir O U o_ O R AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16, Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Type Oty Ply Centex Homes, Model 2227 A X06-003 FDO HIP 1 1 Job Reference (optional) t PFt. P. R. 34946, James L Shoaf 6.300 s Dec 1200 MTek Industries, Inc. Wed Jan 31 14:2724 Universal Forest Inc. E359, Pierce. 2007 Page 1 5-0-0 7-4-0 11-4-0 1 5-0-0 2-" 4-0-0 Scale =1:19. 4x6 = 5x6 3 10 4 T2 5.00 12 5 W2 W2 T3 T1 2 6 1 Y d Bi 8 7 3x6 II 3x6 II 0-0-0 0-0-0 1-M 5-0-0 74-0 114-0 1-M 04-0 38-0 24-0 4-0-0 Plate Offsets 1:0-1-14 0-04:0-1-8 0-1-1z 6:0440.0-3 9:0-1-110-0 0 LOADING (psf) SPACING 2-" CS! DEFL in (too) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.34 Vert(LL) 0.02 8 >999 360 XT 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.36 Vert(TL) -0.04 8 >999 180 BCLL 10.0 Rep Stress Ina NO WB 0.03 Horz(TL) 0.01 6 ria n/a BCDL 10.0 Code FBC2004/TPI2002 (Matra) Weight: 481b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc purtins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid oeiling directly applied or 10-0-0 oc tracing. WEBS 2X4SYP No.2 SLIDER Right 2 X 4 SYP No.2 2-2-11 REACTIONS (Ib/s"rze) 6=370/Mechaniical, 9=515/0--0 Max Horz9=35(load case 6) Max Uplift6=149(load case 6), 9=261(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=344/155, 2-3=-436/219, 3-10=348/212, 4-10=348/212, 4-5=451/223, 5-6=496/213 BOT CHORD 1-9=152/342, 8-9=154/342, 7-8=138/416, 6-7=138/406 WEBS 2-9=341/2D8, 3-8=14/84, 4-8=106/29, 4-7=-6/152 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf: Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by oth(irs) of truss to bearing plate capable of withstanding 149 Ito uplift atjoint 6 and 261 lb uplift at joint 9. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 39 lb down and 59 Ito up at 5-M, and 7 lb down and 67 lb up at 6-2-0, and 12 lb down and 62 lb up at 74-0 on top chord, and 30lb up at 5-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase--1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-4=70, 4-6=-70, 1-0=-20 Concentrated Loads (lb) Vert: 3=1(B) 4=62(B) 8=4(B) 10=67(B) e WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � 0 Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component Safety Informatlon available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M ITSQ Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property -01 13/q *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2, Never exceed the design loading shown and never stack c1-2 c2-3 materials on inadequately braced trusses. WEBS �,� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate o �,� 3 ��� 3 other interested parties. plates 0 -/ie" from outside 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-e csa cs-s OR embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated byANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates, the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available In MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. - ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16, Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss;Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1:. Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate i © 2004 Mitek® Connected Wood Trusses. Job Truss Truss Type Oty Ply Centex Homes, Model 2227 A X06-003 E01 MONO TRUSS 1 1 Job Reference optional) 0-0-0 Universal Forest Product Inc. E359, FL Pierce, Fl. 34SftJ®mes L. Shoaf 6.300 s Dec 1 2005 MTek Industries, Inc. Wed Jan 31 14:27:25 2007 Page 1 3-1-3 6-4-0 r � 3-1-3 3-2-13 4 Scale = 1:14. 5.00 12 3 W1 T1 W3 2 B1 LEH 6 B 9 5 N-0 0- II 1-M 111-12 64-0 , 1-0-0 0-1-12 5-2-4 Plate Offsets :0-1-10 0-0-4 LOADING (psi) SPACING 2-0-0 CSf DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 024 Vert(LL) 0.02 5-0 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.30 Verf(TL) -0.03 5-0 >999 180 BCLL 10.0 Rep Stress Inrr NO WB 0.06 Horz(TL) 0.00 5 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrbr) Weight: 30lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEBS 2X4SYP No.2 REACTIONS (Ib/size) 5=340/0.1.8, 7=453/0.3-8 Max Horz7=117(load case 5) Max Upld5=-264(load case 5). 7=285(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=338/168, 2-3=408/234, 3-4=34/32 BOT CHORD 1-7=161/333, 6-7=-278/333, 6-8=278/333, 8-9=-278/333, 5.9=-278/333 WEBS 4-5=106/66, 3-0=-159/157, 3.5=-362/303, 2-7=251/150 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psF BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Provide mechanical connection (by others) of truss to bearing plate atjoint(s) 5. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 264 lb uplift at joint 5 and 285 lb uplift at joint 7. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 109 lb down and 91 lb up at 3.0-0. and 63 lb down and 71 lb up at 3-5-1. and 63 lb down and 71 lb up at 5-5-1 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=70, 1-5=20 Concentrated Loads (lb) Vert: 6=109(B) 8=-63(B) 9=-63(B) e WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabricatlon, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component Wei° Safe Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property q x,y 13/*Center plate on joint unless Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 0 -'hd' 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-x materials on inadequately braced trusses. 4 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all 4 x 2 orientation, locate opFor �,3 0other ZC6-7 interested parties. plates 0 - /ie" from outside �A� U4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-ece-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1 • required direction of slots In 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12, Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is Installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15• Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss. Construction. M iTek° DSB-89: Design Standard for Bracing. . BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, - Installing & Bracing of Metal Plate ® © 2004 Mitek® Connected Wood Trusses. ,_ Job Truss Truss Type Qty Ply Centex Homes, Model 2227 A X06-003 EG7 MONO TRUSS 1 1 Job Reference optional) Universal Forest Product, Inc. E359, Ft�, Fl. 34946, James L Shoaf 6.300 s Dec 1 2005 bfTek Industrir(f Mpg Wed Jan 31 14:27:25 2007 Page 1 2-9-13 6-0-0 r 2-9-13 3-2-3 3 Scale =1:15. 5.00 12 3x6 2 Wt T1 W3 W2 1 1 1 6 5 3x6 11 7 4 0-0-01x6 11 0-0-0 2-9-13 6-0-0 2-9-13 3-2-3 Plate Offsets 1:0.3-00-0.0 2:0-2-6 0-1-8 5:04-0 0-" LOADING (psf) SPACING 2-0.0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.35 Vert(LL) -0.01 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.37 Vert(M) -0.04 4-5 >999 180 BCLL 10.0 Rep Stress Inr r NO WB 0.30 Horz(TL) 0.01 4 n/a nfa BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 35lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-8 4 oc pudins. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid celing directly applied or 10-M oc bracing. WEBS 2 X 4 SYP Not WEDGE Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 1=1180/0-8-0, 4=1159/Mechanical Max Horz1=1260oad case 5) Max Uplift1=266(load case 5), 4=-325(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1771/377, 2-3=45/28 BOT CHORD 1-6=41411481, 5.6=414/1481, 5-7=414/1481, 4-7=414/1481 WEBS 3-4=95/55, 2-5=298/1451, 2.4=1660/464 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 266 lb uplift at joint 1 and 325 lb uplift at joint 4. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 921 lb down and 212 lb up at 2-0-12, and 921 lb down and 212lb up at 440-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=70, 1-4=20 Concentrated toads (lb) Vert: 6=921(B) 7=921(B) A WARNING - Ver{fij design parameters and READ NOTES ON THIS AND REVERSE BIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 r is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madlson, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property j3/q *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required, See BCSI1. 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 c2-3ng, materials on inadequately braced trusses. WEBS 3. Provide copies of this truss design to the building cc designer, erection supervisor, property owner and all For 4 x 2 orientation, locate �,3 ��'other interested parties. plates 0 - 1/16" from outside O a- U4. Cut members to bear tightly against each other. edge of truss.5, Place plates on each face of truss at each joint and c7-a csa embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated byANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363,.3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING' Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1::National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Mitek® Connected Wood Trusses. mom, �MWONOTRUSS Self* IFIf6ffnEINGA Mi k� Jab Truss Qty Ply Centex Homes, Model 2227 A ' XO6-003 EG7A 1 1 Job Reference w�.na Forest �n Inc.s, r��,Fl.aawa..umo�snea s. .o.�izaos'srxm.e�gp�gw .w iia��as �n+mi 2-it-2 P416 30-0 ter= � �., n ao.o _ 2-11-2 3S-0 6-0-0 � 2.11-2 p-0-14 30-0 Plate 1'62A LOADING SPACING 280 C8 DER �58) TGLL 1D.0 Plates 116 TC 021 VeaLL) -0.� a988 3B0 Mf21� 2MH9U TOOL 5.0 Wnbalmaere 125 BC O.BB Ve�(IL) AQS 68 �999 BO BCLL Pep Shmslm NO WB 0 Xm(ly 0.M 5 Ne Na BfAL COEOFBCNOClIP110M RdeEu)�� Weight WM�t'a BFMAKi TOPCfgRD 2%<SY➢No1 T(N+CHOPD SWduMvaatl NcaWig QaLyepp6etlrc649mµ�in. BOTppRD 2%<Stt+Na2 BOTCW�PO HSmcNinBQ /aGp�n1000mdacYg. WEBS 2%4 SYPNo2 9LIpHi Left rtencnONB Pussml 1�ts�oeo.wrzameax�xai MaxNvz�-r�pmews.$) Ma UpOfl1=Hf�mOmce S7,5=358(IpW p¢¢ 5) Po0.CE8 pD)-WrM1num Compression/Maximum Tension mrawr�o rr-�esrmo. za=>avzi4a+-aani eorawgo YY=-2WRSi.s1=za'lIBsl6�znmsf.sa=-z8]rfiSi WEBS 36--13481�, 45-10L55. %=]5Z3W NOTES 1) Wind: ]-02130irytil3aemM�¢Il MAfl: TCDW1paf, BCOL�.Opsf: Glegwyll: EKp B: ercbseQ MWFRS: pnlikVxleRaMnBMa�metl: Lumber OOlr1.B0 pleb grip OOL=1.60. Nceled clvE INe�roro�rcimNxilM1amY alM1er live 3)M G�a%sa3e0 MtID� m�sdlis�N¢a 4) Wlerro9irclm(slbNwslo Nwamnredv¢ a�eII 61 Hmga1%7 areMM1n�w�v�ec4on�tlev�kelaM EeO�metl euF�aMb OW�w�imnA'ale�il�batl(s ��IbtlopwnaW lE�wD e�0.4waM30a lEtivmiaM t0116upe1 2d-1T. and <421bdmm and 1031pupY 6812mbotlom chord. 1MEeelpNcebgqndeucM1conm�.lbn device(s) ]/1n IM1a LOAD CASE(S) �G¢applaUrollrefa�afValrvss are LOAD Standard +1 Regular:,w�m.in stx. pale izream-i.0 Concentrated Loads lm1 Van: w.m(�7 ]=ca1F18=<u(�7 Aavan s,�re�raioe,w% wmror�we�N.w�irak o�`o��ao`�i.dme aaxa�ecauaoNv w�ao�me�rs shown, oia is ro�onnaww�oi wool Applicability parameters ofwnp�onsnfkies0o�bl%y of building BiodnB �� C este zVtl. M063011 Is support �naMaud web members oNv.��alrempwary. Emcl�g�oinw�e sbdary ilig construction the �eepaNtdRry of e�eclor.AEr➢nmol permanent bracing of the overall structure la the responsibility IN ma WiIG�� CaYgrer. For general guidance regarding raexcanrn a�aM control, naaaa mY�erv, a�eab� and bracing, �onwrc u+sinrn awnN aneno, osaw and wsn evuabw Component m�cawuwca�ate,m Symbols _ PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. -1/16" 0 o= O * For 4 x 2 orientation, locate M plates 0 - 1/16" from outside CL edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but EV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. , BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 ;TEE=LOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Taus Type Ply Centex Homes, Model 2227 A X06-003 EJ2 MONO TRUSS JQty 2 1 Job Reference tonal Universal Forest Product, Inc. E359, Ft Pierce, Fl. 34946. Jame8J0,Voaf 6.300 s De0 - Welk Industries, Inc. Wed Jan 31 14:27:25 2007 Page 1 2-M 2-0-0 Scale: 1.5=1 5.00 12 2 T1 1 W1 B1 4 �g 2-0-0 2-M Plate Offsets 1:0.1-8 0-0.3 LOADING (psi) SPACING 2-M CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.04 Vert(LL) -0.00 1 >999 360 MT20 2441190 TCDL 15.0 Lurnber Increase 1.25 BC 0.03 Vert(TL) -0.00 1-4 >999 180 BCLL 10.0 Rep Stress Ina YES WB 0.01 Hwz(TL) 0.00 Na n/a - - BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight 101b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-" oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-&0 oc bracing. WEBS 2 X 4 SYP No.2 SLIDER Left 2 X 4 SYP No.2 1-7-3 REACTIONS (lb(sae) 1=83/0-3-8, 4=83/Mechanical Max Horz 1=55(load case 5) Max Upliftl=-43(load case 5). 4=79(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=34/0, 2-3=22/19 BOT CHORD 1-4=0/0 WEBS 3-4=65/52 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43 lb uplift at joint 1 and 79 lb uplift at joint 4. LOAD CASE(S) Standard s e WARNING - Verijg design parameters and READ NOTES oN THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component Met ° Safety Information available from Truss Plate Institute, 683 D'Onofrlo Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z cz-a materials on inadequately braced trusses. c3� 4 3, Provide copies of this truss design to the building cc O designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate 0 �,3 O Z other interested parties. plates 0 - 1/16" from outside o �,� U 4. Cut members to bear tightly against each other. edge of truss. CL 5. Place plates on each face of truss at each joint and c7-e csa cs-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS *This symbol indicates the regulated byANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. soffware or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4. perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff, spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Mitek® Connected Wood Trusses. , Taus TypeyCenlex Homes, Model 2227 A XO6-003 MONO TRUSS 6 1 T}�iP Job Reference O O Job TIJ (optional) Universal Forest Product. Inc. E359, FL Pierce, R. 340-tM "NilSafety Information available from Truss Plate Institute, 583 D'Onofr Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 -1/16" from outside edge of truss. *This symbol indicates the _ required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings �Su (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1:.National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, 'Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. IN Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A P AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty, Ply Centex Homes, tytodel 2227 A X06-003 EJ6 MONO TRUSS 3 1 Job Reference o tional Universal Forest Product, Inc. E359, FL Pierce, Fl. 34S� ftJ®mes L Shoat 6.300 s Dec 1 2005 Ivti'fek Industries, Inc. Wed Jan 31 14:27:26 2007 Page 1 r 6-4-0 , 1 6-4-0 s Stele = 1:14. 5.00 12 Wt T1 2 81 4 'A N-0 O-DA II 1-0-0 111-12 6-4-0 , 1-0-0 0-1-12 5-2-4 Plate Onsets 5:0-1-10 0.0.4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (lot) Udefl Vd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.32 Vert(LL) 0.07 45 >879 360 MT20 244/190 TCOL 15.0 Lumber Increase 1.25 BC 021 Vert(TL) -0.07 45 >819 180 BCLL 10.0 Rep Stress Ina YES WB 0.03 Horz(TL) 0.00 Na Na - BCDL 10.0 Code FBC20041TPI2002 (Matrix) Weight 241b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 640.0 oc pudirts. BOT CHORD 2 X 4 SYP Not BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2X4SYP No.2 REACTIONS (lb/size) 4=21510-1-8, 5=342J0-3-8 Max Horz5=.117(load case 5) Max UpliR4=187(load case 5), 5=218(Ioad case 5) FORCES (lb) -Maximum CompressiortlMaximum Tension TOP CHORD 1-2=128/63, 2-3=76/47 BOT CHORD 15=-0/117, 45=0/0 WEBS 3-4=156/108, 25=351/169 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20R; TCDL=4.2psf; BCDL=3.OpsF, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. _ 2) 'This truss has been designed for a 10.0 psf bottom chord live load noncorxxrrrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 187 lb uplift at joint 4 and 218 lb uplift at joint 5. LOAD CASE(S) Standard e WARNING - VeriJy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with M(Tek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer -not truss designer. Bracing shown Chesterfield, MO 63017 y bracing to Insure stability during construction is the responsibility of the ' is for lateral support of Individual web members only. Additional temporarSofeAt erector. Additional permanent bracing of the overall structure Is The responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component ' Information avrilInhIp from Truss Plate Institute. 83 D'O ofrlo Drive Madison WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. c,-z cz-a WEBS c3� 4 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate m ir �,,, ��' 3 other interested parties, plates 0 -' /16" from outside 0 a_�d� 19 U 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-8 c6-7 ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. . software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14• Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15• Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings,occur• 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek@ DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, ®� a Installing & Bracing of Metal Plate °^ , © 2004 Mitek® Connected Wood Trusses. Job Truss Truss Type Qty Ply Model 2227 A XO6-003 Fr16U MONO TRUSS 0-0-0 3 =Centex �� (optional) Universal Forest Product, Inc. E359, FL Pierce, Ff. 34946, JaOtB,g Shoaf 6.300 s Dec 12005 PofTek Industries, Inc. Wed Jan 31 14:27:26 2007 Page 1 5-0-0 5-0 Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/a *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1, Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 0-1hd' 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack C1-2 c2-3 materials on inadequately braced trusses. WEBS oa, 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all For 4 x 2 orientation, locate �,� 3 3 M other interested parties. plates 0 - /ie" from outside truss. O O 31A6 U OR " 4. Cut members to bear tightly against each other. edge of o_ 5. Place plates on each face of truss at each joint and c7-e csa ces embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from Connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated b symbol shown and/or y y BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12, Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ff. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, �•• 11151 Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Job Tnus Truss Type Qty Ply Homes, Model 2227 A X06-003 EJ7U MONO TRUSS 17 7CAentex b Reference (optional) 201l0-00 Universal Forest Product, Inc. F_359, FL Pierce, Fl. , James L Shoaf 6.300 s Dec 1 2005 MTek Industries, Inc. Wed Jan 31 14:27:26 2007 Page 1 7-0-0 3 Scale = 1:15. 5.00 12 T1 2 1 Bt 3K4 = 4 20}0-m0 0-0-0 3t6 II 1-0-0 11-4-0, 7-0-0 1-0-0 0-4-0 5-8-0 Plate Offsets 5:0-1-11 0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.39 Vert(LL) -0.04 4S >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 •_ BC 0.26 Vert(M) -0.11 45 >504 180 BCLL 10.0 Rep Stress Ina YES WB 0.03 Horz(TL) 0.04 3 Na Na BCDL 10.0 Cade FBC2lX)4lTPI2002 (Matrix) Weight 221b LUMBER BRACING TOP CHORD 2 X 4 SYP Not TOP CHORD Structural wood sheathing directly applied or 6-0.0 oc purtire. BOT CHORD 2 X 4 SYP Not BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2X4SYP No.2 REACTIONS (lb/size) 3=174/Mechanipl, 4-64/Mechanical, 5=38610-0.0 Max Ho25=131(load case 5) Max Uplift3=110(load case 5), 5=149(load case 5) Max Grav3=174(load case 1), 4=104(load case 2), 5=386(load case 1) FORCES (lb) -Maximum Compressior7fMaximum Tension TOP CHORD 1-2=154/56, 2-3=-84/52 BOT CHORD 1-5=-0/131, 45=0/0 WEBS 2-5=358/228 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This buss has been designed for a 10.0 psf bottom chord live load nonwnatrrent with any other live loads. 3) Refer to girders) to buss to buss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 3 and 149 lb uplift atjoint 5. LOAD CASE(S) Standard A WARNWG - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MlTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite 4300 Applicability of design parameters and proper Incorporation of component 1s responsibility of building designer -not truss designer. Bracing shown Chesterfield, MO 63017 ' Is for lateral support of Individual web members only. Additional temporary bracing To Insure stability during construction is the responsibility of the erector. Additional permanent bracing of The overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Crfierla, DSB$9 and BCSI1 Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53779. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 Cc O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside a edge of truss. 0 *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4. X 4. perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output, Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A e TEE.=LOK No C'0 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1, Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a. 5. Place plates on each face of truss at each joint and OOP embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator, General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements, 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14, Connections not shown are the responsibility of others. 15, Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Thus Truss Type Oly Ply Centex Homes, Model 2227 A X06-003 F01 FLOOR 8 1 Job Reference o tional Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L Shoal 6.300 s Dec 1 2005 biTek Industries, Inc. Wed Jan 31 14:27:27 2007 Page 1 0-4-8 H I— 1=� 2-0-0 O O 0-IN IV; IV 11=2 � scale =126 z7%Z Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 1/16" 0 O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside a OP edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling; Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A MiTek� PM T�EEi.=°OK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4: Cut members to bear tightly against each other. CL 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements, 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitee Job Truss Truss Type Oty Ply Centex Homes, Model 2227 A X06-003 F02 FLOOR 7 1 Job Reference o tlonal Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L Shoaf 6.300 s Dec 1 20051u1tTek Industries, Inc. Wed Jan 31 14:27:27 2007 Page 1 0-4-8 H � 1-3-0H 0-1� 0-14� , 2-0-0 1-1-1V 4� Scale = t:za. 4x6 11 1.50 11 1.6x4 II 46 = 1 2 3 4 5 6 7 6 9 1, 4 W 17 16 15 14 13 12 11 1 1.5x4 11 4x6 = 4x6 = 1-5-0 0-0-0 Q-4 6-0-6 7-S$ 8-6$ , 15-0-12 , 0-4-8 6-1-14 1-0-0 1-0-0 6-6-6 Plate Offsets 1:0-3-0E e 13:0.1$ Ed 14:0.1-8,E a [17:Edge,0-0-121 LOADING (psi) SPACING 2-0.0 CSI DEFL in (loc) Well L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.51 Vert(LL) -0.10 12-13 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.55 Vert(TL) -0.1412-13 >999 240 BCLL 0.0 Rep Stress Ina YES WB 0.21 Horz(TL) 0.01 10 r✓a n!a BCDL 5.0 Code FBC20lW/TPI2002 (Matrix) Weight 841b LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0.0 oc purlins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceding directly applied or 100-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 10=798/Mecflaniral, 1=79810-4-0 FORCES (1b) -Maximum Compression/Maximum Tension TOP CHORD 1-17=0/6, 5-10=792/0, 1-2--603/0, 2-3=599/0, 3.4=143710, 45=185010, 5-6=1850/0, 6-7=1850/0, 7-8=1454/0, 8-g=�61310 BOT CHORD 16-17=0/0, 15-16=0/1126, 1415=0/1722,13-14=0/1850,12-13--0/1726,11-12=0/1156,10-11=0/0 WEBS 5-14=301/0, 6-13=250/0, 1-16=0/902, 3-16=-838/0, 3-1rr-0/485, 415=-461/0, 414=22/469, 9-11=0/922, 8-11=-861/0, 8-12-0/473, 7-12=-033/0, 7-13=31/421 NOTES 1) Unbalanced floc live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) Refer to girder(s) for truss to truss connections. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - Verijy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with Mifek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer -not truss designer. Bracing shown 14515 N. Outer Forty, � Suite #300 Chesterfield, MO 63017 ' Is for lateral support of individual web members only. Additional temporary bracing To Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute 583 D'Onofrlo Drive, Madison WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property j1/4 * Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. � 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 cz-s materials on inadequately braced trusses. WEBS c3v 4 3. Provide copies of this truss design to the building O designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate m a �� 3 other interested parties. plates 0 -/ie" from outside edge of truss. O O U 4. Cut members to bear tightly against each other. O 5. Place plates on each face of truss at each joint and c7-e cs-� ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes, trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. • responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification'for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, �9■ Installing & Bracing of Metal Plate ® © 2004 MiteV Connected Wood Trusses. entex Homes, Model 2227 A X06-003 FLOOR Reference o tlonal Universal Forest Product, Inc. F-359, Ft. Pierce, Fl. 34946, James L Shoaf 6.300 s Dec 1 2005 A,STek Industries, Inc. Wed Jan 31 14:27:28 2007 Page 1 0-4-8 1-3-0 , 1-5-4 „ 2-0-0 -5-d Q f-1 stela =1:35. 3x6 FP= 3x6 11 axe = 5x6 11 4x6 11 3x5 II 3x6 II 3x4 = 3x4 = 1.5x4 11 3x4 = 4x6 = 5x6 = 1 2 3 4 5 6 7 B 9 10 11 12 TO W 5 W 5 W 5 W 5 W yw 24 23 22 21 20 19 1817 16 15 14 1.5x4 II 46 = 46 = 1.5x4 II 5x5 = 3x4 = 300 MT18H FP= 3x5 = 46 = 5x5 = 3x4 11 3x4 = 1-5-0 0-0-0 44-r6 5-9-12 6-9-12,7-9-12, 21-2-13 , 04-8 5-5-4 1-0-0 1-0-0 13-5-1 Plate Offsets 1:0.3-0E e 3:0.3-0E 4:0-3-00.0-0 13:E 0.1-8 , 20:0.1-8 E e 23:0-2-0Ed f24:Edge,0.0-121 LOADING (psf) SPACING 2-0.0 CSI DEFL in (lac) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.95 Vert(LL) -0.35 19-20 >710 480 PA'f20 2441190 TCDL 10.0 Lumber Increase 1.00 BC 0.83 Vert(TL). -0.5519-20 >454 240 MT18H 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.32 Hom(TL) . 0.04 13 n/a rJa - BCDL 5.0 Cade FBC2004frPI2002 (Matra) Weigh: 129 lb LUMBER BRACING TOP CHORD 4 X 2 SYP Not TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purfins, except end verticals. BOT CHORD 4 X 2 SYP SS 'Except' BOT CHORD Rigid ceding directly applied or 10-0-0 oc bracing. B2 4 X 2 SYP No.2 WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 13=1137/0-3-8, 1=1137f0-" FORCES (lb) -Maximum CompressionlMaximum Tension TOP CHORD 1-24=5/3, 12-13=1131/0, 1-2=902/0, 2-3=2395/0, 3-0=-3328f0, 45=3328/0, 5-6=3865/0, 6-7=3868/0, 7-8=3720/0, 8-9=3269/0, 9-10=3269/0, 10-11=2304/0, 11-12=916/0 BOT CHORD 23-24=0/0, 22-23=0/1721, 21-72=0/3328, 20-21=0/3328, 19-20=0/3758, 18-19=0/3853, 17-18=0/3584, 16-17=0/3584, 1516=0/2857, 1415=0/1731, 13-14=0/0 WEBS 3.21=0/336, 4-20=0/1202, 1-23=0/1358, 2-23=126910, 2-22=011045, 3-22=1310/0, 12-14=0/1376, 11-14=1295/0, 11-15=0/909, 10-15=-877/0, 10-16=0/636, 9-16=-&i/0, 8-16=-486/0, 8-18=01217, 7-18=210/0, 7-19=-61/183, 5-19=127/276,r20=1555/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are INT20 plates unless otherwise indicated. - 3) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 17 and 6. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING -Verify design parameters and READ NOTES ON THIS AND REVERSE 9IDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MRek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility, of buildingdesigner- not truss designer. Bracing shown Chesterfield, MO 63017 y bracing to Insure stability during construction is the responsibility of the ' is for lateral support of individual web members only. Additional temporarSrijefy erector. Additional permanent bracing of the overall structure is The responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component Information available from Truss Plate Institute 583 D'Onofrlo Drive, Madison, WI 53779. O k° Job TFru3 ss Truss Type =Job Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/q *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates t0 both sides Of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X bracing, Is always required. See BCSI1. 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack o,-z cz-3 materials on inadequately braced trusses. WEBS oa, 4 3. Provide copies of this truss design to the building m designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate m m v �,� �� � other interested parties. p plates 0 - 1/16" from outside O 19 4. Cut members to bear tightly against each other. edge of truss. 0 U I EL 5. Place plates on each face of truss at each joint and c7-8 c6-7 ca-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6, Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur, Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSII : Building Component Safety Information, Guide to Good Practice for Handling, ® Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. 311YP1 ]ro]Pe 0-0�8 I-1 �'3'0� tsa zao t�i5 s� � �.ewn a.s- as= �.snn �san unex m- aa= aa- as= ..s= aan iso aoa l� 59-72 ii-11-11 19315 �8-9-12 �]-&12� � � o-ae 6sa �-ao ��ao ai-is �-aa Plate L:61A :61 Bb2 1 b2d 001 LOADING SPACING 2d0 dl OFA In (�) YtlM W PLATES GRIP TCLL G0.0 plates Increase L00 TC U VsgLL) A31618 M38 MiA 2iY180 TOOL 10.0 Lumber Increase .1.0p BC O.W_ VeryR) �0 %fi 2b �g12 M�1B11 2iY180 BCLL 00 Rep lrvs YES WB 0 HattR) 004 Na Na BC0. 6 Code FBCNM/IPiRroi (M )� WdjC 1101b wnee� eivarw TOP d%RSYPNo3 TOPp10RD SNa9irA xvaE NiaNliiig Etec&/applzEa22-0x W�Ire. ecmq end verticals. T CHORD /X23YP 55 £v�pl• BOTLHOM Rigid ceiling EtraEyepplbtlalOPU mbatlr9. Except. @0%25TP Not 22-0rctrany�MF31.132(1.1618. WEBS <X25YPNo3 �ncrwxe ovma� �z-�uvwaa. i=iaAa�aw FORCES lel-w'muncanweszmrvMaimumterer.� TOPCHORD i-Z1�-1NY,11-1Y-102d0.1-2-�059.29=-896b.1Y4W]A.Cb-��90Cp,b8Ut01Po.&A3101N.]d=R6G'J.64--2]9TIQ 910�MWA, 10.11�2W �T CHORD YL13--0.tl,21.II�'14�. ZIL21=6"1&�4.1&Hk01Rd.1&19=N2B00.1]-18=N 181,1&11�31B1. iS1fi0f1868. 1415N1516.1}16�'ifi61. t2-13=0A 1B0 WEBS 49k014]9.618�id8Po.&ieN214.11-13�H231. 1615-11540.10.10.-01182&14=]50.0,415=0.W5.61S--353.0.1-12bIIMi6.3}3=10CIPo.321=01820.621-118JN. ]-16--391N. )-1B=ZId1d].618�931580 NOTES i)IIMSIargetlflaarlNebeEa M1ara EemoasAeeO fatlYSUevBn zl ai gams are nmo paw w� andw.a mamma. 31 T�a(olbxingpM(sl repu�replateineµ inspection Tool�GuMMMIgEMrnt�SNns'seM1ceenlarwMityazwrarce trdpech"on'I]sN& d) Recommend shan86ecM4m eE�. spaced at f600 mantlfas�eretlbeacii Wuxi1M131fitl mks. StrmBbadab be alladaErowa�aetllielrMs WlapcMee.an��a�iai�oreia�u��cae� 51 GnD�M�ean nSitle not exceed 6) ��Tlau. w not erect backwards. LOAD Standard A - �awisn naAmse.s �e READ NOTES orr THIS AND �vswse sms eerou uae. Outer Forty, Design wia M use only with nvta4<wnect«s.mh tle9pn bosses only won parameters shown, and Is for an �msvitlua� buYtltiB component. Applicability of parameters proper EWbi�Geslpire�.no�M1untlasgner.&ocing shown �e�'retl. Id0690� k for lateral support M IMv'r4ol w� rtremEen onlyAdditional temporary E�arJnO ro Insure stability during construction 6 Me ienpowEllry IN the nal permanent bracing of Me arerdl structure 6 the �enpon�blllry of Me EUIItlFg tl gna. For general guidance regrntlln0 fabrication, p�tlily control storage, delivery ��n mtl bracing, �"+��t AN51/1%1 8ua0ry Criteria, �SB89 mW BC911 Bulltlln9 k� Universal Ege,h Rnw, Fl.31816, James 6JOOs0ec 5 ek ,mu Wed Component Symbols PLATE LOCATION AND ORIENTATION t3/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths, Apply plates to both sides of truss and securely seat. 0 X O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13, Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14.. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install, and load vertically unless indicated otherwise. © 2004 MiteV Job Tnus Truss Type pry Ply Centex Homes, Model 2227 A X06-003 FO6 FLOOR 5 1 Job Reference o tional Universal Forest Product. Inc. F_359, FL Pierce, Fl. 34946, James L Shoaf 6,300 s Dec 1 2005 MTek Industries, Inc. Wed Jan 31 14:27:29 2007 Page 1 0-4-8 1-3-0 , 1-5-4 2-0-0 1-5-3 , Scale =1:20. 3x5 II 1 2 3 4 5 6 7 W 4 14 13 12 11 10 9 1.5x4 11 1.5+c4 II 1.5x4 11 3x5 = 1-5-0 0-0-0 PA:� 5-9-12 6-9-12 7-9-12 12-1-7 , 0-4-8 5-5-4 1-0-0 1-0-0 4-3-11 Plate Offsets 1:03-0 E e 4:0-1-8 E e 5:0-1-8 E e 8:0-2-0E 14:E a 0.0-1 LOADING (psf) SPACING 2.0.0 CSI DEFL in (loc) Well Lid PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.41 Vert(LL) -0.09 11-12 >999 480 tU1T20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.63 Vert(li) -0.1211-12 >999 240 BCLL 0.0 - Rep Stress Irxx YES WB 0.16 Horz(TL) -0.02 8 rJa n/a BCDL 5.0 Code FBC2004ffP12002 (Matrix) Weight 681b LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0.0 oc puriirls, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 8=636/03.8,1=636/0-4-0 FORCES (lb) -Maximum CompressioNMaximum Tension TOP CHORD 1-14=0/8, 7-�-08/0, 1-2=-465/0, 2-3=-461/0, 3-0=1030/0, 4�r--1169/0, 5-6=-812/0, 6-7=0/0 BOT CHORD 13-14-0l0, 12-13=0/869, 11-12=0/1169, 10.11=011169, 9-10=0/1169, 8-9=0/521 WEBS 4-11=134/71, 5-10=39/164, 1-13=0l694, 3-13=-64710, 3-12=01275, 4-12--309/0, 6-8=782/0, 6-9=0/463, 5.9=524/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 M720 unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10.0-0 or and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. _ 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard e WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with Mfiek connectors. This design is based only upon parameters shown, and is for an Individual building component. Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown 14515 N. Outer Forty, r• Suite #300 Chesterfield, MO 63017 ' is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component fabrication, quality control, storage, delivery,Safft Information available from Truss Plate Institute. 683 D'Onofrio Drive. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 Ir O * For 4 x 2 orientation, locate plates 0 -/ie" from outside a edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings NqA (supports) occur. Icons vary but 17 reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® tex Homes, Model 2227 A X06-003 F07 FLOOR 1 Reference O O Job Truss Truss Type Qty Ply Tjo (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate plates 0 - 'N' from outside edge of truss. OR *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1, Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is Installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® 2227 A X06-003 F08 FLOOR 2 1 Job Reference O O Job Truss Truss Type ay Ply Centex Homes, Model (optional) Universal Forest Product, Inc. E359, FL Pierce, Fl Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Proper/ Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. c,-2 cza 0 03 4 WEBS 3. Provide copies of this truss design to the building cc O o designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate � m It � �,3 �� 3 other interested parties. p plates 0 - 1/16" from outside 0 0 n. �°� U 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-e csa ce-s embed fully, Knots and wane at joint locations are BOTTOM CHORDS *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII . 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MITek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior Lie reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPII : National Design Specification for Metal , Plate Connected Wood Truss Construction. A iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, I Installing & Bracing of Metal Plate 4 kill © 2004 Mitek® Connected Wood Trusses. Job Truss Truss Type Cityty Ply Centex Homes, Model 2227 A X06-003 F09 FLOOR 7 1 Job Reference (optional) Universal Forest Product Inc. E359, FL Pierce, R. 34946, James L. Shoat 6.300 s Dec 1 2005 A4Tek Industries, Inc. Wed Jan 31 14:27:30 2007 Page 1 0-" 3x6 FP= = 3x5 11 3x5 11 3x10 3x4 = 3x4 = 3x5 = 3x4 = 1 2 3 4 5 6 7 8 9 10 11 4 W 5 W 5 W t 5 W 15 W 24 23 22 21 20 19 18 17 16 15 14 13 12 1.50 II 1.5x4 II 1.5x4 II 3x10 tuTT18H FP= 3x4 = 1.5x4 II 1.5x4 II 3x4 = 1-5-0 1-5 M1 Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. *For 4 x 2 orientation, locate plates 0 -1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated, BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. I Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 R LO.Komk AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10, Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Type city plyCentex Homes, Model 2227 A X06-003 TFG SPECIAL 1 2 Job Reference (optional) UbLNRWI Forest Product, Inc. F_359, FL Pierce, Fl. 34946, James L Stwaf 8.300 s Dec 1 2005 trTTek Industries, Inc. Wed Jan 31 14:27:30 2tj-0jbage 1 6-4 , 4-1 al 1 sa-s 14-Ef 4-10-11 4-8-15 4-10-11 scale=l:2a. 3x4 II 3x4 = 6x6 = _ 1 5xe _ 9 10 2 11 12 3 13 14 4 61 7 6 KI 4x6 II 5x10 = 4x8 II 0-0-0 0-0-0 4-10-11 9-7-9 14-0-4 , 4-10-11 4-8-15 4-10-11 Plate offsets 1:a3-12 az-o :a1-1z,a1-a 4:0-3-8az-1 6:0-2-8a2-s :o44 az-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (lac) Well Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.95 Vert(LL) -0.21 6-7 >800 480 MTZO 244l190 TCDL 10.0 Lumber Increase ._ 1.00 BC 0.58 Vert(TL) -0.33 6-7 >504 240 BCLL 0.0 a .Rep Stress InNO WB 0.77 Haz(TL) 0.02 5 r✓a n!a BCDL 5.0 Code FBC2004lrP12002 (Matrbc) Weigh: 1651b LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 TOP CHORD Structural wood sheathing directly applied or 3-7-9 oc purtins, except end verticals. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. WEBS 2 X 4 SYP No.2'Exoept' W1 2X6SYP SS, W12X6SYP SS REACTIONS (IWsize) 8=3131/0-3-8, 5=3298/03S FORCES (lb) -Maximum CompressionlMaximum Tension TOP CHORD 1-8=-2771/0, 1-9=7675/0, 9-10=7675/0, 2-10=7675/0, 2-11=7675/0, 11-12=767510, 3-12=7675/0, 3-13=7826/0, 13-14=7826/0, 414=7826/0, 45=2974/0 BOT CHORD 7-8--0/1397, 6-7=0/7826, 5.6=011386 WEBS 1-7=0/6515, 2-7=2017/0, 3-7=157/0, 3.6=2012/0, 4-6=0/6683 NOTES 1) 2-ply truss to be connected together with 10d (0.131'k3") nails as fellows: � Top chords connected as fellows: 2 X 6 - 2 rows at 0.9-0 oc, 2 X 4 -1 row at 0-7-0 oc. Bottom chords connected as fellows: 2 X 6 - 2 rows at 0-9-0 oc. - Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 698 lb down at 1-5-12, 698 lb down at 3-5-12, 698 lb down at 5-5-12, 698 lb down at 7-5.12, 698 lb down at 9-5-12, and 698 lb down at 11-5-12, and 698 lb down at 13-5-12 on top chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Floor: Lumber Irxxease=1.00, Plate Inaease=1.00 Uniform Loads (pif) Vert: 14=100, 5-8=10 Concentrated Loads (lb) Vert: 3=-698(F) 9=698(F)10=-696(F) 11=-698(F) 12=-698(F) 13=-698(F) 14=698(1`) e WARNING -Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite t1300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer -not truss designee Bracing shown Chesterfield, MO 63017 ' is for lateral support of individual web members only. Additional Temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designee For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component Safetv Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/, * Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 cc O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but EV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury I . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. EL 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection, 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® 2227 A X06-003 FG2 FLOOR 1 1 Job Reference O O Job Truss Truss Type Qty Ply Centex Homes, Model (optional) I Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L Shoat 6.300 s Dec 1 2005 fNTek Industries, Inc. Wed Jan 31 14:27:30 2007opm Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 M O *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. _ . *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but Ev, reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses, 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. IL 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11, Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Ply Centex Homes, Model 2227 A X06-003 GE1 GABLE 1 1 Job Reference O Job Thus Truss Type City (optional) Universal Forest Proc"JOc. E359, FL Pierce, Fl. 34946, James L Shoal Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property -01 14-13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 c2-3 materials on inadequately braced trusses. WEBS c3v 4 WEBS 3. Provide copies of this truss design to the building cc Om erection supervisor, property owner and all or 4 x 2 orientation, locate v �,� 3 �,�' 3 other interested parties. plates 0 -/ie" from outside O CLsae U 4. Cut members to bear tightly against each other. edge of truss. °- 5. Place plates on each face of truss at each joint and c7-8 csa ce-6 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6, Design assumes trusses will be suitably protected from connector plates. the environment In accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: 'Design Standard for Bracing. t . BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 MiteV Connected Wood Trusses. Job Truss Taus Type Qty Ply Centex Homes, Model 2227 A X06-003 HJ2 MONO TRUSS 1 1 Job Reference tional Universal Forest Product, Inc. E359, Ft PiercOJ(].§4946, James L. Shoat 6.300 s Dec 1 2005 MiTek Ir�u�s, Inc. Wed Jan 31 14:27:31 2007 Page 1 2-9-15 4 , 3 2-9-15 scaie:l.s=1 3.54 12 2 T1 1 W1 B1 6 5 ias 11 2-9-15 , 2-9-15 Plate Offsets 1:0-2-4 0-1-10 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.12 Vert(LL) -0.00 1-6 >999 360 MT20 244/190 TCDL 15.0 Lumf>arlrxxease 1.25 BC 0.07 yert(TL) -0.01 1-0 >999. 180 BCLL 10.0 Rep Stress Irxx NO WB 0.01 Horz(TL) 0.00 Na Na BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight 121b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-9-15 oc puriins. BOT CHORD 2 X 4 SYP Not BOT CHORD Rigid calling directly applied or 10.0.0 oc bracing. WEBS 2X4SYP No.2 SLIDER Left 2 X 4 SYP No.21-6-12 REACTIONS (lb/size) 1=117/0-4-15, 6=129/Mechanical Max Horz 1=56(load case 3) Max Uplift1=72(load case 3), 6=104(load case 3) FORCES (lb) -Maximum Compression/Maximum Tension TOP CHORD 1-2=3810, 2-3=-22/20, 3-0=2/0 BOT CHORD 1-6=0/0, 5.6--0/0 WEBS 3f=98/67 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.0psf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed fora 10.0 psf bottom chord live load nonconcurtent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 72 lb uplift at joint 1 and 104 lb uplift at joint 6. LOAD CASE(S) Standard 1 e WARNDYG -Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with Mfiek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 • is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison WI 53719. Symbols PLATE"LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside n. edge of truss. o *This symbol indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. d 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice p fi' 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated b symbol shown and/or y y BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitee Connected Wood Trusses. Job Truss Truss Type Qty Ply Ce�Homes, 0 O Model 2227 A X06-003HJS MONO TRUSS 2Jo (optional) Universal Forest Product, Inc. E359, FL Pie5ib-A4 34946, James L Shoaf 6.300 s Dec 1 2005 MTek Industries, Inc. Wed Jan 31 14:27:31 2007 Page t r 3-10-9 7 Symbols PLATE LOCATION AND ORIENTATION 13/4 * Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. O *For 4 x 2 orientation, locate plates 0 - 1/16" from outside o- edge of truss. 0 *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. CONNECTOR PLATE CODE APPROVALS LATERAL -BRACING Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate connected Wood Trusses. " AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator, General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise, © 2004 Mitel& Homes, Model 2227 A X06-003 HJ7A MONO TRUSS 2 1 Job Reference O k® Job IT"'M Truss Type Qty Ply Centex (optional) Universal Forest Product, Inc. E359, FL -0-0 Pierce, Fl. 34946, James L Shoaf 0 6.300 s Dec 1 20051�ifek Industries, -L--1 V 0 Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. R *This symbol indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated, ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitee Connected Wood Trusses. Job Truss Thus Type 0 0 Qty Ply Centex Homes, Model 2227 A X06-003 HJ7U MONOTRUSS 4 1 Job Reference (optional) 201-0-0 Universal Forest Product, Inc. FbWt. Pierce, Fl. 34946, James L Shoat 6.300 a (>ac 12005 MTek Industries, Inc. Wed Jan 31 14:27:31 2007 Page 1 , 5-10-4 9-10-13 , � 5-10-4 4-0-9 3 Scala 31 a 3.54 12 2 7 T1 W2 W1 � HW1 61 9 6 10 5 4 2010-0 3x8 11 0-0-0 1-5-0 ,1-10, 1�5$-15 9-10-13-8-15 9-10-13 , 1-5-0 0-5-11 3-10-5 4-1-13 Plate Offsets 1:0-310 0-0-3 1:0-0-131-10-4 LOADING (psf) SPACING 2.0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.33 VeR(LL) -0.02 1-6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.36 Vert(M) -0.07 1-6 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.22 Horz(TL) 0.01 4 Na Na BCDL 10.0 Cade FBC2004/TPI2002 (Matra) Weight: 42 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc purlirts. BOT CHORD 2 X 4 SYP N0.2 BOT CHORD Rigid ceiling directly applied or 10-0.0 ac bracing. WEBS 2X4SYP No.2 WEDGE Left: 2 X 6 SYP SS REACTIONS (lb/size) 3=124/Mechanical, 4=340/Mechanica1,1=409/0-11-5 Max Harz 1=131(load case 3) Max Uplift3=72(load case 3), 4=123(load case 3), 1=128(load case 3) FORCES (Ib) -Maximum CompressioNMaximum Tension TOP CHORD 1-7=-793/221, 2-7=714/235, 2-8=-04/3, 3-8=-24/27 BOT CHORD 1-9=3081713, 6-9=-308f713, 6-10=3081713, 5.10=308A13, 4-5=0/0 WEBS 2-6--0/228, 2-5=-783/338 NOTES 1) Wiry: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed fora 10.0 psf bottom chord live load nonconcun•ent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Refer to girders) for truss to Symbols PLATE LOCATION AND ORIENTATION i'/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths, Apply plates to both sides of truss and securely seat. 0 Cc O * For 4 x 2 orientation, locate v plates 0 -1/16" from outside edge of truss, O a. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. 5W_1Ii40 1:1:LT•]1►C BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. C- 5. Place plates on each face of truss at each joint and embed fully Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements, 11. Lumber used shall be of the species and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior 16. approval of a professional engineer. Install and load vertically unless indicated otherwise. MiTek° O © 2004 Miteke uss Truss Type Oty Ply Centex Homes, Model 2227 A X06-003 VALLEY 2 1 Job Reference optional) Universal Forest Product, Inc. E359, FL EtaMFl. 34946, James L. Shoat 0.Dec 12005IutiTek Iry�ustries, Inc. Wed Jan 31 14:27:32 2007 Page 1 r 2-0-0 r r 2-0-0 Scale =1:5.1 s.00 12 � T 81 � 2-0-0 2-0-03x4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (lac) Udefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.02 Vert(LL) Na - Na 999 MT20 244H90 TCDL 15.0 Lumber Increase 1.25 BC 0.01 Vert(TL) Na - Na 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 Na Na BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight 5 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0.0 oc bracing. REACTIONS (Ihlsize) 1=4512-0-0, 2=35/2-0-0, 3=10/2-0.0 Max Horz 1=24(load case 5) Max Upliftl=9(load case 5), 2=24(laad case 5) Max Grav1=45(load case 1), 2=35(load case 1), 3=20(Ioad case 2) FORCES (lb) -Maximum CompressiortfMaximum Tension TOP CHORD 1-2=15/13 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20fb TCDL=4.2psf; BCDL=3.Op6f Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed fora 10.0 psf bottom chord live load norxwncurreht with any other live loads. 3) Gable requires continuous bottom chord bearing. 4) Bearing atjoint(s) 2 considers parallel to grain value using ANSUTPI 1 angle to gram formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 9 lb uplift at joint 1 and 24 lb uplift at joint 2. LOAD CASE(S) Standard A WARNING - VeriJy design parameters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MITek connectors. This design is based only upon parameters shown; and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 y bracing to Insure stability during construction Is the responsibility of the " Is for lateral support of individual web members only. Additional temporarSafely erector. Additional permanent bracing of the overall structure Is The responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component 1' Information avallable from Truss Plate Institute 583 D'Onofrio Drive Madison, WI 53719. �( O O Jab rMV2 Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 * Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 0-1/01 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-z materials on inadequately braced trusses, o 4 3. Provide copies of this truss design to the building ir designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate ZC23 oother interested parties. plates 0 - /ie" from outside a0 v4. Cut members to bear tightly against each other. edge of truss.EL 5. Place plates on each face of truss at each joint and c7-sce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11, Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12, Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur, 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mite[& Connected Wood Trusses. �„a �r 0 aa Symbols Numbering System ®General Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1. 0-'/�b" 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. c1-2 c2-3 WEBS 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate o � �,� ��� cc other interested parties. plates 0 -/ie" from outside O "< U 4. Cut members to bear tightly against each other. edge of truss. ° a- 5. Place plates on each face of truss at each joint and c7-8 cea ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. - JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT - 9. Camber is a non-structural consideration and is the - The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11, Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or. Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. 9F number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction. M ITeke DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses.