Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS�Awnae ovgO6.0/-O3or- DATE FILED: "1 . 2,4' .01 PLAN REVIEW FEE: _ GQ RECEIPT NO.: �� 2"� « PERMIT NUMBER: C (�N'-�I CONCURRENCY FEE: RECEIPT NO.: CERT. CAP. NO.: ALL INFO MUST BE COMPLETE u FILLED IN TO BE ACCEPTED cGy� SCANNED ST. LUCIE COUNTY PUBLIC WORKS co - BUILDING & ZONING DEPARTMENT BY VIRGIIA AVENUE 9RWP St. Lucie County FORT PIE CENFL 34982- 652 772-462-1553 APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: .12 Palo Alto SPANTSH T.AKP.$ T 2. S/D NAME: _Spanish Lakes I SITE PLAN NAME: 3. PROPERTYTAX ID #: Part of 3414-5.01-1701-000/9 4. LEGAL DESCRIPTION (attach extra sheets if necessary): Section 26, Township 36S andy Range 40E 5. PLAT. 6. PAGE 7. BLOCK -8. LOT BOOK NO. NO. NO. 9. PARCEL SIZE: ACRES/SQ FT. 5 2M LOT DIMENSIONS 10. DESCRIPTION OF CONSTRUCTION PROJECTOR WORK ACTIVITY: Family Residence Laurel Model R;ght MP#0601-0305 on file Replacement home 11. ' SETBACKS (ACTUAL) FRONT: (/ BACK: ✓ RIGHT LEFT t/ SIDE 61 SIDE: -in, 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) V,I( NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION [K] RESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL [ ] OTHER (SPECIFY) 13. DESCRIPTION OF PROPOSED USE: Residence 14. Sq. Ft./CONSTRUCTION: 1904 15. ' Sq. Ft. 1 st Floor: 16. VALUE OF CONSTRUCTION: $ $ 81, 8 7 2.0 0 � j% 7 r. 0 9 � Z The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify th indicated value of construction if it is demonstrated that the submitted figures are not co sistent with similar types of construction activities. If the value is $250 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form.N6.: 001-02 OWNER INFORMATION: NAME: Wynne Building Corporation ADDRESS: Qrinn G —1T�— fir c„ _ },e- - 4 4;,?-- (XIBCL4 cZ 122- h8MX CITY: P n r i 9 s it NI Q14 M STATE: F L- ZIP PHONE (DAYTIME): (7721 878-5513 ' . '-Z>5t IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): ( ) CONTRACTOR INFORMATION ST. of FL REG./CERT #: C G C 0 3 5 9 9 ST. LUCIE COUNTY CERT #: 08898 BUSINESS NAME: Wynne Development Corporation QUALIFIERS NAME: Matthew Lyle Wynne ADDRESS: 8000 S. US #1, Suite #402 , CITY: Port St. Lucie STATE- FL • ZIP 34952 PHONE (DAYTIME): (772) 878-5513 FAXNO. 772-878-7656 ARCHITIENGINEER: ADDRESS: CITY: PHONE (DAYTIME): BONDING COMPANY: ADDRESS: CITY: MORTGAGE LENDER: ADDRESS: CITY: Baden & Bran en 4' coconut Ave. Stu a r t STATE.. F' L ZIP - 3� Q �— (772) 287-8258 STATE: ZIP ZIP IMPORTANT NOTICE: When a permit is issued and it is not picked up within g days_ after notification it will be voided and returned to you by mail. STATE: CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits•may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, ETC., not otherwise included with this building permit application. Tlhe' 41lfowing building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPL CANT:' AS THE APPLICANT FOR THIS BUILDING PER IT, IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMEN , AS A CONDITION OF THIS PERMIT YOU PROMISE IN GOOD FAITH TO DELIVER A COPY F THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPE TY IS SUBJECT TO ATTACHMENT. OWNER'S AFFID 1T I certify that all the foregoing information is accur lUning. d that all work will be done in compliance with all applicable laws regulating construction a OWN R SIGNATURE STATE OF FLORIDA COU.NTYOF St. Lucie bThe foregoing instrument was acknowledged Ma- etgee �me this 2 Q t Wa of 20� by L o is ersonally known t me or who yha roduced as identification. Signature of ary CONTRACTOR SIGNATURE STATE OF FLORIDA COUNTY OF St. L•uci e The foregoing instrument was acknowledged Lbefore me this n t a 20 , by Matthew L W n n e who is personally known to - or w has D a as identification. Signature of Not Type or Print Name of Notary Type of Print Name of Notary Notary Public Title Notary Public Title Commission Number Commission Number �r ay •., SUSAN MAGEE (seal) =4 MY COMMISSION # DD 630093 (seal) EXPIR66: 4bruary.23.2011 a Bonded 7hru Notary Pup_l o'.Unaa wri ers 't° * MY COPv,')y19sQEE r NOTE: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NO . DinaarAn��(ota rua Q�83 IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER Y PEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. SECTION: 0 -b TOWNSHIP: ?bS RANGE: l{©E MAP NO.: ZONING: Rm" J LAND USE: 013, 1 LOT CVG %: 62 TAZ NO.: FLOOD ZONE: Y FIRM MAP #: F 1ST FLR ELV: MAX HGT: CST TYPE: OCCP TYPE: MAX. OCCP: # OF FLRS: WATER: �� 1 SEWER: SPRINKLERS STORMWATE R LOT OF REC (befr 1/90) LOT OF REC (aftr 1/90) LOT SPLIT LOT SPLIT REQ'D APPRV'D DECAL LIBRARY PARKS PERMIT NUMBER IMPACT FEE IMPACT FEE FEE j REPORT CODE 1 Q 1 PUBLIC BLDG IMPACT FEE HABITABALE AREA RADON FEE K ^ Q� Y (RADON) Y N ROAD�1i1� • GROSS ROAD CREDIT TOTAL ROAD IMPACT ZONE IMPACT FEE DUE IMPACT FEE Y SCHOOL- - CREDIT TOTAL E IMPA FEE SCHOOL 1CMPA T FEE POLICE FEE FIRE FEE MISC FEES: TOTAL POLICE/FIRE/ MISC: FEES Y N ELECT�C/L°. ADDITIONAL SPECIFY: XA,,; TOTAL ALL PERMITS FEES REQ'D .�✓9 REVIEWS ZONING ZONING PLANS VEGETATION SEA MANGROVE REVIEWED BY EXAMINING TURTLE DATE (� COMPLETE INITIALS n.L." 9P 3U4b9bZ OR BOOK 2804 PAGE 2577, Recorded 04/24/2007 at 01:27 PM J J' NOTICE OF COMMENCEMENT J e Off "O i,' State Tax ID#Part of 3414-501-1701-000/9 State County Of S t. Lucie THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Legal Description ofpropertyand street address, ifavailable Section 26, Township 36S and Range 40B 12 Palo Alto k General description ofimprovements—Single family re. -,id; -ore Owner Address 8000 S. ion U.S_# t Suite #402 Port St Lucie FL 349 52 Owner's interest, in site ofimprovement. Fee Simple Fee Simple Title holder (if other than owner) Fee S i m p l e Address Contractor Wynne Development Co o i n Phone# 772-878-5513 Address_ 8000 S_U.S #•1,Suite #402,1? FL 34952 Fax# 772-878-7656 Surety Address Phone # Amount of Bond $ Fax # Lender Address Phone it Fax # Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7., Florida Statutes: Name Douglas- Brantley, Mana er 4F' #772-878-3011 Address1 Silver Oak Drive., p L, FL•34952 772-340--30194 In addition to himself, owner designates of (Phone # Fax # ) to receive a copy of theLicnoes Notice as provided in Section 713.13(1) Statutes. Expiration date ofnotice ofcommencement is one year from the date ofrecording unless a is specified. (Date) STATE OF FLORIDA, COUNTY OF S t r.11rip OWNERS SIGNATURE Acknowledged before me this 00, day of Apri i 2N 7 ,byMa t t h e to i.�, l=TAJY own to rwho has produced as identification. (seal) SIGNATURE fiM'fii}, sU TYPE OR PRINT NAME OF NOTARY sr1N1MDFE K MYCDhIM13810N N DD &90093 NOTARY PUBLIC TITLE ' � E7tPIRE9; February 23, 2D11 COMMISSION NUMBER SIATE OF FLORIDA ST. LUCIE Cour l'y C• � E , •; i—'sP,r, l-t) (; rii iF't ' ilia"# 'i"rl; Ti't'tUEANDCf1RRECTGOP,f:):T E ` I-1CIr 10 UYN T Y CLr !, 1F C13Q € iel;)1(AM (;•tv• I) ,qw 4 CERTIFICATE OF OCCUPANCY This Certificate is issued pursuant to the requirements of the Florida Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of St. Lucie County regulating building construction or use. For the following: Building Permit No. - , 0704-0441 Parcel/Folio Nbr: 3414-501-1701-000/0 Lot # Block: Subdivision: St Lucie Gardens S/D Occupancy: Residential - 1 & 2 family dwellings Building Address: 12 PALO ALTO Legal Description: ST LUCIE GARDENS 26 36 40 BLKS 1 AND 2 LYG ELY OF US 1 R/W LESS RDR S/W.SPANISH LAKES #1 Permit Job CONSTRUCTION OF SINGLE FAMILY RESIDENCE - LAUREL MODEL RIGHT Description * MASTER PERMIT # 0601-0305 * Permit Finaled: 12/13/2007 Contractor 10 6WYNNE DEVELOPMENT CORP (772) 878-5513 8000 S US 1 PORT ST LUCIE, FL 34952 Christopher Lestrange Building Official Thursday, December 13, 2007 Date Printed NOTE: This Certificate of Occupancy is issued to the above named, for building at the above named location only upon the express provision that the applicant will abide by -and comply with all the conditions of the Zoning Ordinances and all Ordinances or Building Codes of Saint Lucie County pertaining to the erection, construction or remodeling of buildings or structures. This also certifies that the electrical wiring and/or equipment, and the plumbing work have been inspected and approved. The issuance of this Certificate grants permission to occupy and use the property described herein only for the use indicated. Any change in use will require a new Certificate of Occupancy. POST IN A CONSPICUOUS PLACE C CERTIFICATE OF OCCUPANCY This Certificate is issued pursuant to the requirements of•the Florida Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of St. Lucie County regulating building construction or use. For the following: Building Permit No. - 0704-0442 Parcel/Folio Nbr: 3414-501-1701-000/9 Lot # Block: Subdivision: St Lucie Gardens S/D Occupancy: Residential - 1 & 2 family dwellings Building Address: 76 E MEDITERRANEAN BLVD Legal Description: ST LUCIE GARDENS 26 36 40 BLK 1 AND 2 LYG ELY OF US 1 R/W LESS RDR S/W SPANISH LAKES #1 Permit Job CONSTRUCTION OF SINGLE FAMILY RESIDENCE - LAUREL MODEL LEFT Description Permit Finaled: 12/13/2007 Contractor WYNNE MATTHEW L WYNNE DEVELOPMENT CORP (772) 878-5513 8000 S US 1 PORT ST LUCIE, FL 34952 Christopher Lestrange Building Official Friday, December 14, 2007 Date Printed NOTE: This Certificate of Occupancy is issued to the above named, for building at the above named location only upon the express provision that the applicant will abide by and comply with all the conditions of the Zoning Ordinances and all Ordinances or Building Codes of Saint Lucie County pertaining to the erection, construction or remodeling of buildings or structures. This also certifies that the electrical wiring and/or equipment, and the plumbing work have been inspected and approved. The issuance of this Certificate grants permission to occupy and use the property described herein only for the use indicated. Any change in use will require a new Certificate of Occupancy. POST IN A CONSPICUOUS PLACE .,.A' RECEIVELY D DEC 14 297 HULETT Pmblac �Wprks etavironwcnt.ai services .S. L it rt.�.+ 32 CQ4nty, . 1. Pre -Construction Termite 1-800-285-7378 Property Information Treatment Date (/0 Time ®a2,o Lot A Block Subdi sionnlName �/' // 1 a, Pak 1 /1 141z Street Address (If known) L � /::�� City State Zip Qua ityPro re,qztment -bq Builder/Contractor Zf WA& f Name of Builder Shell Contractor Construction Type Monolithic OFloating/Stemwall OPatio Owner's Name (If known) ❑Entry ❑Driveway ❑Other: Product/Treatment Information Treatment Type: ❑ Underslab ❑ Patio/Driveway Final Wood Treatment ❑ Bait System ❑ Other Product: CID*;P�ermethrin dium Octaborate (Boracare) ❑ Cypermethrin ❑ Other: c Concentration Mixed Product Applied 45 SquAe Feet Treated Linear Feet Treated q 71 If this box is checked, then Final Perimeter treatment has been completed and the following statement is applicable: Certificate of Compliance: This building has received a complete treatment for the prevention of subterranean termites. This treatment is in accordance with the law d rules ablis d by the Florida Department of Agriculture and Consumer Services. Applicator's Name (please print) HES-TE019 07/07 's Signature Hulett Environmental Services© 2007 b CERTIFICATE OF OCCUPANCY This Certificate is issued pursuant to the requirements of the Florida Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of St. Lucie County regulating building construction or use. For the following: Building Permit No. - 0704-0441 1 Parcel/Folio Nbr: 3414-501-1701-000/0 Lot # Block: Subdivision: St Lucie Gardens S/D Occupancy: Residential - 1 & 2 family dwellings Building Address: 12 PALO ALTO Legal Description: ST LUCIE GARDENS 26 36 40 BLKS 1 AND 2 LYG ELY OF US 1 R/W LESS RDR S/W SPANISH LAKES #1 Permit Job CONSTRUCTION OF SINGLE FAMILY RESIDENCE - LAUREL MODEL RIGHT Description * MASTER PERMIT # 0601-0305 * Permit Finaled: 12/13/2007 Contractor 10 6WYNNE DEVELOPMENT CORP (772) 878-5513 8000 S US 1 PORT ST LUCIE, FL 34952 Christopher Lestrange Building Official Thursday, December 13, 2007 Date Printed NOTE: This Certificate of Occupancy is issued to the above named, for building at the above named location only upon the express provision that the applicant will abide by and comply with all the conditions of the Zoning Ordinances and all Ordinances or Building Codes of Saint Lucie County pertaining to the erection, construction or remodeling of buildings or structures. This also certifies that the electrical wiring and/or equipment, and the plumbing work have been inspected and approved. The issuance of this Certificate grants permission to occupy and use the property described herein only for the use indicated. Any change in use will require a new Certificate of Occupancy. POST IN A CONSPICUOUS PLACE Code Compliance Division Ft. Pirc,Virginia 349 2 INSPECTION CARD Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 hftp://stiucieco.gov/ce Permit #: SLC- 0704-0441 Conf A 753 Type: Building Residential (SFR) Issued 06/15/2007 Status: FIN Double Fee: No Job Location 12 PALO ALTO City, PORT ST LUCIE Jurisdiction: St. Lucie County Lot: Block: Parcel: 3414-501-1701-000/0 Subdiv: St Lucie Gardens S/D Flood: Elev: Flood Map: Job Description: CONSTRUCTION OF SINGLE FAMILY RESIDENCE - LAUREL MODEL RIGHT * MASTER PERMIT # 0601-0305 * Setbacks Left: 10.00 Right 6.00 Inspection Notes: Front 32.00 Rear: 16.00 Contractor 10 6WYNNE DEVELOPMENT CORP (772) 878-5513 8000 S US 1 PORT ST LUCIE, FL 34952 Property Owner WYNNE BUILDING CORP (772) 878-5513 8000 S US1 STE 402 PORT ST. LUCIE, FL 34952 SUB -PERMITS Permit # Status PT Cert # DBA Owner / Builder Job Description 0704-0441-01 FIN EP 4267 JOE'S ELECTRIC OF ST LUCI 0704-0441-02 FIN PP 17488 ART STOVER PLUMBING INC 0704-0441-03 FIN ME 8288 COMFORT CONTROL OF ST 1 0704-0441-04 FIN RP 19085 ROOF CONCEPTS INC INSPECTIONS - For Requests, Call: (772) 462-1261 Permit # Code Description Priority Date Sched. Res Description Inspector Date Insp. 0704-0441 425 Sewer Connect 0 06/29/2007 90 Approved Gary Gerstemeier 06/29/2007 null Scheduled: Thu Jun 28 13:16:49 EDT 2007 with value: Fri Jun 29 00:00:00 EDT 2007 0704-0441 104 Compaction Test 1 06/18/2007 90 Approved Frank Williams 06/18/2007 0704-0441 105 Form Board Survey 1 06/26/2007 90 Approved 0704-0441 420 Plumbing Rough 1 06/29/2007 90 Approved null Scheduled: Thu Jun 28 13:16:16 EDT 2007 with value: Fri Jun 29 00:00:00 EDT 2007 0704-0441 427 Temp.Toilet/Temp Culvert 1 06/29/2007 90 Approved 0704-0441 103 Eufer Ground 2 07/10/2007 90 Approved null Scheduled: Mon Jul 9 15:35:06 EDT 2007 with value: Tue Jul 10 00:00:00 EDT 2007 Resulted: Tue Jul 10 13:55:40 EDT 2007 0704-0441 115 Slab 2 07/10/2007 90 Approved null Scheduled: Mon Jul 9 15:36:02 EDT 2007 with value: Tue Jul 10 00:00:00 EDT 2007 Resulted: Tue Jul 10 13:56:03 EDT 2007 0704-0441 121 Termite Spray 2 07/10/2007 90 Approved null Scheduled: Mon Jul 9 15:36:43 EDT 2007 with value: Tue Jul 10 00:00:00 EDT 2007 Resulted: Tue Jul 10 13:56:27 EDT 2007 0704-0441 118 Column 3 07/20/2007 81 Disapproved Lydia Galbraith 06/26/2007 Gary Gerstemeier 06/29/2007 Gary Gerstemeier 06/29/2007 Dave Johnson 07/10/2007 Dave Johnson 07/10/2007 Dave Johnson 07/10/2007 Dave Johnson 07/20/2007 Permit Nun 0704-0441 null . 0 Scheduled: Thu Jul 19 15:27:38 EDT 2007 with value: Fri Jul 20 00:00:00 EDT 2007 0704-0441 118 Column 3 07/24/2007 90 Approved Dave Johnson 07/24/2007 Re -inspection 1 Scheduled: Mon Jul 23 15:28:45 EDT 2007 with value: Tue Jul 24 00:00:00 EDT 2007 Resulted: Tue Jul 24 14:00:19 EDT 2007 0704-0441 125 Tie Beam 3 07/24/2007 90 Approved Dave Johnson 07/24/2007 Re -inspection 1 Scheduled: Mon Jul 23 15:33:29 EDT 2007 with value: Tue Jul 24 00:00:00 EDT 2007 Resulted: Tue Jul 24 13:59:54 EDT 2007 0704-0441 125 Tie Beam 3 07/20/2007 81 Disapproved Dave Johnson 07/20/2007 null need to address continuous footer on back patio before pouring beam Scheduled: Thu Jul 19 15:28:21 EDT 2007 with value: Fri Jul 20 00:00:00 EDT 2007 Resulted: Fri Jul 20 14:16:02 EDT 2007 0704-0441 133 Window/Door Bucks 4 08/10/2007 90 Approved Greg Smyth 08/10/2007 null Scheduled: Thu Aug 9 09:00:55 EDT 2007 with value: Fri Aug 10 00:00:00 EDT 2007 Resulted: Fri Aug 10 14:35:13 EDT 2007 0704-0441 134 Roof Sheathing 4 08/06/2007 90 Approved Dave Johnson 08/06/2007 null Scheduled: Fri Aug 3 16:02:56 EDT 2007 with value: Mon Aug 6 00:00:00 EDT 2007 Resulted: Mon Aug 6 14:39:51 EDT 2007 0704-0441 137 Strapping 4 08/06/2007 90 Approved Dave Johnson 08/06/2007 null Scheduled: Fri Aug 3 16:03:54 EDT 2007 with value: Mon Aug 6 00:00:00 EDT 2007 Resulted: Mon Aug 6 14:39:02 EDT 2007 0704-0441 145 Truss Drwg 4 08/06/2007 90 Approved Dave Johnson 08/06/2007 null Scheduled: Fri Aug 3 16:04:30 EDT 2007 with value: Mon Aug 6 00:00:00 EDT 2007 Resulted: Mon Aug 6 14:39:27 EDT 2007 0704-0441 127 Mullion 5 08/23/2007 90 Approved Dave Johnson 08/23/2007 null Scheduled: Wed Aug 22 15:39:24 EDT 2007 with value: Thu Aug 23 00:00:00 EDT 2007 Resulted: Thu Aug 23 14:38:22 EDT 2007 0704-0441 135 Wall Sheathing 5 93 Not Required Joe Cicio no wall sheathing to be inspected per contractor * 09/10/2007 0704-0441 136 Roof Dry-in/Tin Tab 5 08/16/2007 90 Approved Dave Johnson 08/16/2007 null Scheduled: Wed Aug 15 15:26:20 EDT 2007 with value: Thu Aug 16 00:00:00 EDT 2007 Resulted: Thu Aug 16 13:51:22 EDT 2007 0704-0441 140 Construction Rough Frami 5 09/06/2007 90 Approved Dave Johnson 09/06/2007 null Resulted: Thu Sep 6 14:49:00 EDT 2007 0704-0441 148 Window/Door Attachment 5 09/06/2007 90 Approved Dave Johnson 09/06/2007 null Scheduled: Wed Sep 5 15:54:37 EDT 2007 with value: Thu Sep 6 00:00:00 EDT 2007 Resulted: Thu Sep 6 14:48:37 EDT 2007 0704-0441 238 Electric Rough 5 09/06/2007 90 Approved Dave Johnson 09/06/2007 null Resulted: Thu Sep 6 14:49:20 EDT 2007 0704-0441 351 Mechanical Rough-In(ducl -5 09/06/2007 90 Approved Dave Johnson 09/06/2007 Re -inspection 1 Resulted: Thu Sep 6 14:50:00 EDT 2007 0704-0441 423 Plumbing Top Out 5 09/06/2007 90 Approved Dave Johnson 09/06/2007 null Resulted: Thu .Sep 6 14:49:41 EDT 2007 0704-0441 650 Frame -all 5 09/06/2007 74 Cancelled by Building I Barbara Counsello 09/06/2007 null Scheduled: Wed Sep 5 15:55:09 EDT 2007 with value: Thu Sep 6 00:00:00 EDT 2007 0704-0441 141 Insulation 6 09/12/2007 90 Approved Dave Johnson 09/12/2007 Plan specs 10' ceiling height * HVAC Loads based upon an 8' ht. May need revision * Jmc Scheduled: Mon Sep 10 10:32:56 EDT 2007 with value: null Scheduled: Tue Sep 11 08:58:25 EDT 2007 with value: Wed Sep 12 00:00:00 EDT 2007 Resulted: Wed Sep 12 16:10:15 EDT 2007 0704-0441 167 Roof Final 6 09/12/2007 90 Approved Dave Johnson 09/12/2007 null ' Scheduled: Tue Sep 11 08:59:00 EDT 2007 with value: Wed Sep 12 00:00:00 EDT 2007 Resulted: Wed Sep 12 16:10:26 EDT 2007 Permit Nun 0704-0441 0704-0441 259 Power Release Form 0 6 92 Accepted As Note Frank Williams 06/29/2007 0704-0441 115 Slab 7 10/17/2007 ' 90 Approved Dave Johnson 10/17/2007 REAR PATIO SLAB ONLY 10/16/07 schedule for jean/ contr. bac 0704-0441 121 Termite Spray 7 10/17/2007 90 Approved Dave Johnson 10/17/2007 0704-0441 153 Insulation Certification 7 92 Accepted As Noted Barbara Counsello 10/09/2007 0704-0441 260 30 Day for Testing 7 11/13/2007 90 Approved Dave Johnson 11/13/2007 null Scheduled: Fri Nov 9 12:50:57 EST 2007 with value: Tue Nov 13 00:00:00 EST 2007 0704-0441 800 Address Final 7 11/13/2007 90 Approved Dave Johnson 11/13/2007 0704-0441 172 Hurricane Panels (shutter; 8 12/13/2007 90 Approved Dave Johnson 12/13/2007 0704-0441 261 30 Day Expired 8 01/14/2008 92 Accepted As Noted Barbara Counsello 12/13/2007 0704-0441 804 Driveway Bldg 8 12/13/2007 90 Approved Dave Johnson 12/13/2007 0704-0441 808 Landscaping/Trees 8 12/13/2007 90 Approved Dave Johnson 12/13/2007 0704-0441 996 Final Termite Treatment 8 12/13/2007 90 Approved Dave Johnson 12/13/2007 0704-0441 999 Final Inspection 8 12/13/2007 99 Final Approval Dave Johnson 12/13/2007 null Scheduled: Wed Dec 12 16:56:51 EST 2007 with value: Thu Dec 13 00:00:00 EST 2007 Permit Nun 0704-0441 -� RIVED HL7LETT casironmcntnl �rvlcsw Pre -Construction Termite 1-800-285-7378 OCT 18 2007 Public Works ist, Lucia County pl kz". Treatment Property Information Builder/Contractor ����QQ Treatment Date i�� VTime �e�'�- _ "4�'l�3'� c!� Name of Builder Lot Block � /—� � �� Subdivision Name Shell Contractor 1 fla'I A Const uction Type Street Address (If known) Vi�� Monolithic Floating/Stemwall City State Zip - / Patio J`' Entry Driveway Owner Name (If known) Product/Treatment Information I)reatment Type: Underslab Patio/Driveway Final Other Wood Treatment Product: Disodium Octaborate (Boracare) Proubu1ild TC Cypermethrin Other �117 Ji)1 Concentration Mixed Product Applied Square Feet Treated Linear Feet Treated ❑ If this box is checked, then Final Perimeter treatment has been completed and the following statement is applicable: Certificate of Compliance: This building has received a complete treatment for the prevention of subterrranean termites. This treatment is in accordance with the rules and laws establis ed by the Florida Department of Agriculture and Consumer Services. 2 C Applicator's Name (please print) Applicator's Signature HES-TE019 Rev 05106 ©Hulett Environmental Services 09/27/2007 07:45 FAX 772 409 8758 SALE INSULATION •IM 007/007 AL W 0 z 0 allow _J z City of Port. Saint Lucie Building^.Department;. .. INSULATION CERTIFICATION Permit #: �[L,[_:_.i 2 9(41 Insulation Contrador Warne: GALE INSULATION Jobsite Contractor, �►'��' lw'G�%Q•'�! Jobaite Address: I?— Palo_ °. 9 200? Section: Block: Lot: :5 �. Coiling Ina Manufactures Name: CERTAINTEED � Insulation Type: FIBERGLASS BATT R Value of Insulation: 19 . Thickness of Insulation Instgtlle -. 6.25 INCHES Location of Insulation installed: A/C CEILING AREA Date of Installation: _ I RT 1. o 4 — Insulation Manufactures Name: FI-Poll CORP insulation Type: _ REFLECTIVE FOIL R Value of Insulation.__ 4. 9 Thickness of Insulation Instilled: 3 / 4 INCH Location of Insulation Installed: CBS EXTERXOR WALLS Date of Installation: q / Pa Please Check One: ❑ Attic insulation installed with ventilation per R806.1, R806.2 and R806.3 Florida Residential Code 2004 0 Conditioned attic assembly insulation has been installed per R-806.4, Florida Residential Code 2004 THIS C#W MUST BE POSTED IN A PROMINENT LOCATION AND RETURNED TO Ti,IE ING P RTMENT BEFORE YOUR FINAL INSPECTION. � pSL07-9389 Insulation Contractors Signature PSL License # 09/27j2007 07:44 FAX 772 48817.56 GALE INSULATION __ Ib 006/007 [1!!n crion under this permit will be done In accordance with the new FISCIFRC 2004 CITY OF PORT SY WCIE SulmlCQNTRACToR. PERMIT TYPE OF PERMrr (PIMG. Elk:. AC. SUL. GAS SOLAR PERMIT # MASTER PERMIT mum wr C k 1 u QMI� i�aof�s C- t•�: ""l CA5 1 1 a �1�+ iC, J GALL INSULATION 3601-A Cro:;aroads Pkwy Ft:-Pierce,34945 9389 Coin w=; A nFAx 77291 489- 75 Residential C.'LM GWVXM �t✓tBF ❑APentere �ALi6}QaN �Oi11at cift �ivim.1 %Y• l t Me"cvNaRwKe: VAUUMOW. 1HI5 PERMIT BECOMES NULL AND VOID IF CONSIRUCIION OR WORK AUTHORIZED IS NOT COMMENCED WITHIN b MONIHS, OR IF CONSTRUCTION OR WORK IS SUMDED OR ABANDONED FOR A PERIOD OF 6 MONTHS AT ANY TIME AFTER WORK 13 commENCED. 4WNER'�AI�4v11: I Choi tithe Io�poFlp Mfofnlglh(t a at:a�de ontfrid) d wioticw� L70 done b oor�IQtce wtlh eNcpgMcal,ie 14�t�oergaanM�llenatd�orltp. . WAtiNMmOMVM, YOURFAUN 1DRF:CM11NMOFCOMNOC6MMI1YA NVWtPAYMNAM FOR 60MM ff M YLMIR PPOPEMY. F1, 718.1MY1 IFYd11t1M100WXfl 4CM00NWWIffl0t1LLiW0rtAN REtbpDl�i�1WNOi1G�OFQOMMFNC� ram, ^U sanain of vweaata PM) iWr as 0W* 1rt oWrffIB ) `owhw a&,. "Q Und=ay Hudson Commission r DDS M1® 1 Expires Octobw 7, aoio iM Cv1.1ti�F�-tiwaln.frt taetislAl� i i �t LTt or +' PBW VA UDAWN CHIC M'0L sVYC�1 tAffORE ME ON71� pA1PgF 20 CAM BARN * , Ulm #,_�� `K �°�,. �.i RECEIVED IN FKA. HULETT sa.�iroumc�sa, Pre -Construction Termite 1-800-285-7378 JUL 10 2007 Public Works St. Lucie County, FL �v - Treatment Property Information Builder/Contractor Treatment Dane Time '25 '—CFO �— aN me ofBuilder--�—� Lot Block Subdivision Name % Shell Contractor Tci 'CT 4[ it0 ��? v Construction Type Street Address (If known) YS f✓ rR Monolithic Floating/Stemwall City State Zip Patio Entry Driveway Owner Name (If known) Product/ reatment Information 1Yeatment Type: Underslab Patio/Driveway Final Other Wood Treatment CG- . Product: Disodium Octaborate (Boracare ) Other Concentration_ Mixed Product Applied Square Feet Treated _VCA 12 Linear Feet Treated ❑ If this box is checked, then Final Perimeter treatment has been completed and the following statement is applicable: Certificate of Compliance: This building has received a complete treatment for the prevention of subtenTanean termites. This treatment is in accordance with the rules and laws established by the Florida Department of Agriculture.and Consumer Services. Applicator's Name (please print) Applicator HES-TE019 Rev 05/06 ©Hulett Environmental Services SJ _ VIE&TI)UNLBERGER ENGINEERP i & TESTING INC. ~ Project Name: Spanish Lakes �—� 4. . v,14 1 Report Date: 05-09-07 Port St. Lucie, Florida Address: 12 Palo Alto Client Name: WYNNE Building Corporation ! ` Project No.: 05-10-2005 8000 U.S. 1, Suite 402 Date Tested: 05-08-07 Port St. Lucie, Florida 34953 Technician Initials: NOP Attn: Ms. Janet Toombs Progress Report No.: 15 (Sheet 1 of 1) Test No. Probe Depth (in) Maximum Dry Density (ef) Optimum Moisture (%) Dry Density (ef) Cone Resistance' (tsf) Moisture M Minimum Required Compaction %) Percent Maximum Dens!! Test Result 1 12 107.5 13.0 103.6 - - - 9.6 95 96.4 Pass 2 12 107.5 13.0 103.4 - - - 8.8 95 96.2 Pass 3 12 107.5 13.0 103.7 - - - 9.2 95 96.5 Pass Type of Field Density Test: () ASTM D 1556 (X) ASTM D 2922 Q ASTM D 2937 Minimum Required Compaction Based on: (X) AASHTO T-180 (ASTM D 1557) Q AASHTO T-99 (ASTM D 698) 1C mmnactinn nerrent ectimnted frnm cone nenetrnmeter reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. ewe, R �„�.Elexahon�:� 1 1 0-12 At front of lot 2 1 0-12 At center of lot 3 1 0-12 At back of lot 0-2 —® Elevation Referenced to: {Soil T . 'e t.l. 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Note: The original of this report was signed and sealed by VD () MSL (X) Other Inches below top of final grade. cc: Client...(1) "B" (772-201-8443) will pick up ... (2) �aig E. Dunkelberger, P.E. FL vstrW6 No.49'932 r �.2007, . a registered engineer in accordance with Rule 61G15-18.011 of the Florida Administrative This report is submitted as the confidential property of our client and authorization for publication of statements, conclusions, or extracts from or gazdrnl this report is reserved pending our written approval. The above -referenced testing was performed at the locations and depth interv' i described erein on the associated report date. No other warranties with regard to subsurface exploration, recommendations or design are expressed by this firm. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stlucieco.gov/ce Issued: 06/15/2007 Conf #; 753 BUILDING PERMIT Permit #: SLC- 0704-0441 Job Location: 12 PALO ALTO City: PORT ST LUCIE Permit Type: Building Residential (SFR) Job Description: CONSTRUCTION OF SINGLE FAMILY RESIDENCE - LAUREL MODEL RIGHT * MASTER PERMIT # 0601-0305 Subdiv: St Lucie Gardens S/D Lot: Block: Parcel: 3414-501-1701-000/0 Page 1 Contractor 10 6WYNNE DEVELOPMENT CORP (772) 878-5513 8000 S US 1 PORT ST LUCIE, FL 34952 Property Owner WYNNE BUILDING CORP (772) 878-5513 8000 S US1 STE 402 PORT ST. LUCIE, FL 34952 Setbacks Left: 10.00 Right: 6.00 Number of Units: 1.00 Floors: 1 Minimum Floor Elevation: Job Value: $ 0.00 Front:32.00 Rear: 16.00 Buildings: 1 Flood Map: 283F Flood Zone: Zoning: RMH-5 Square Footage: 1,904.00 X Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange �- /L.5-- DV 677 Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1653 Fax: (772) 462-2522 hftp://stiucieco.gov/ce Date: 15 June 2007 Job Address: 12 PALO ALTO Received By: goycochb Paid With: CK Paid By: WYNNE DEVELOPMENT Building Receipt Receipt#: 0000055051 'ermit Number: SLC- 0704-0441 Amount: $1,138.49 �redit Card Number: Check Number: 028327 Sign: Wynne Development Corp. 8000 South US1, Suite 402 Port St. Lucie, FL 34952 To: Lydia - . St. Lucie County Zoning Department Fax #: 462-2522 From: Ann Carabia Date: 05/07/2007 Pages: 1 (including cover) �J Office: 772-878-5513 Ext. 115 Fax: 772-878-7056 The proposed finished floor elevations for the following permits: 0704-0440 8 Rio Verde Way Above Road 21" 07_04-0441 12 Palo Alto Above Road 22' 0704-0442 76 Mediterranean East Above Road 20" BUELDING & ZON7, 3 DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR SUMMARY WYNNE DEVELOPMENT CORPORATION will be using the (=npanyfWd1Mual name) following sub -contractors for the project located at S1Pal panishoLakes I (straet address or property tau ID 0) , It is understood that if there is any change of status regarding the participation of any o; the sub -contractors listed below, I will immediately advise the .Building and Zoning Department of St. Lucie County. Trade Name of ComparrylContractor St. Lucle Countyl State ofFlorida Ucanae Number r 17488 pluffd3iny _ Art Stover Plumbing Inc. y . FC056644 Ekctdcal Joe's Electric of St. Lucie 04267 Co., Inc. !R0009122 8288 NVAC/Merhankal l Comfort Control of SLC., Inc- CACO24379 19085 Roofing.. Roof Concepts., Inc. CCC0"5.8 241 Gas Hurricane Protection "Alufab, Inc. LBC052127 .irrrUt MR: WILT: sLccov FORM NO.: 0034H 7pr=RMrr NUMBER: ISSUE DATE: ST. LVCIE COUNTY PUB 1' WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT. _,. _ SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number. State of Florida Certification Number (if applicable): 17488 , CFC05664 Art Sxover Plumbing Inc.—, has agreed to be (companylndividual name) the _ plumbing- - • - _-_ sub -contractor for Wynne Development Corporation (type of construction trade) (name of the prime contractor) .12 Palo Alto for the project located at Spanish Lakes I It is understood that, (street address or property tax ID X) if there is any change of status regarding our participation with the above mentioned project, 1 will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO.004-00). BUSINE A IFIER (original signatures required): Arth _ Rtn��c.r_ � 04/20/07 signature Print name Date business name; f Art Stover P1 rimhi nn me-, address: 554-NW Mercantile Placer;: city,state,2ip: port St. Lucie, FL 34986 phone: 772,-�Q,78-6929 -oo ST. LUCIE COUNTY PU':', -11C WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number. State of Florida Certification Number (If applicable): 04267 , ER0009122 Joe's Electric - has agreed to be (companyrindividual name) the electrical _..._ (type of construction trade) sub -contractor for Wynne Development Corporation (name of the prime contractor) for the project located at G12 Pal® Alto -i- --akes ' � . It is understood that, (street address or property tax ID #) if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO. 004-00). BUSINESS QUALIFIER (original signatures required): Joseph Herndon....._ t 4/20/07 si nature Print name Date business name: I Joe's EleCtriC of St. Lucie do. Inc. address: 951 Wag-ner., Place city,state,zip: Fort Pierce; F 49.82 phone:' 7 2 65— OFFICEUSEIONEY: SLCCDV FORM NO.: 002-00 PERMIT # I I ISSUE DATE ST. LUCIE COUNTY PUE�_rC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number, State of Florida Certification Number (If applicable); CACO24379 Comfort Control_ of; SLc.!. Inc. has agreed to be (company/individual name) the air co-nd-i-t on-ing Sub-contractorfor Wynne Development Corporation (type of construction trade) (name of the prime contractor) '12 Palo Alto for the project located at Span i sh' r.a kP.G T It is understood that, (street address or property tax ID #) if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St_ Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO. 004-00). BUSINESS QUALIFIER (original signatures required): Barry' Zimmerman.r Abusines Print name Date name: ('nm-F 0 rt__CnnrraI of _q ham_ address; 1501 Ri 1-mn-rP n,; city,state,zip: Port Sta Lucie, rr .34AR3 phone: 772r7.285_-9010 OFFICEUSEM- NLY: SLCCDV FORM NO.: 002-00 n ST. LUCIE COUNTY PUBLWORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St Lucie County Contractor Certification Number. State of Florida Certification Number of applicable): 19085 , CC-0058241 Roof Concepts Inc.- has agreed to be (commnyAndividuel norm) the roofing. - - Sub-Contractorfor wYnne Development Corporation (type of construction trade) (name of the prime contractor) lo for the project located at Spani s nl ° Lak e ss I It is understood that, (Street address or property tax ID f) if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the -Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM No. 004-00). NESS QUALIFIER (original signatures required): Anthony L. Per.1 a 04/20/07 Print name Date business name: Ro_Qf C n n e P t G. T n a_ address: 2121 SW en n,A n3_ A 3Zp _ _ city,state,zip: Port St. Lucie f FL 34953 phone:' 772-344-371,7 SLCCDV FORM NO.: 00-00 PERMIT X I I ISSUE DATE FROM :ALUFAB HURRICANE SHUTTERS FAX N0. :3056898033 or. 20 2007 11:28AM P2 ST. LIJCIF COUNW FVBLIC.+ WORKS BUILDrNG & ZONING DEPART1Vx'ENT BURMNa3>zUMT SUB -CONTRACTOR AGREEDUM St. Ude County Contmetor Certification Nur*w. State of Florida Cert(tFcation Number (if miic I C S= 0 5 212 7 A 134 f a h , T n ag _ _ _ have agreed to be the (Compmyllux/ladivi"I Ndmc) bm:r_ac i s a e s h.UJ o r s_ sub-contractorfor Wvn n e DS v e t o m. n t C o r p (1-y" of Trsdc) ("Taory Contactor) - . 12 Palo Alto for the project located at S p a n i a r T, a k P s T a (Project Street Address or Property Tax 10 #) It is understood that, if them is any change of status regarding our participation with the above mentioned project, X will immediately advise the Bolding and Zoning Department of $t. Lucie County by personally filing a Change of Contractor notice. (Form: sLCCDV No. 004-00) BUSMESS QUA LMER (Nome of ehc Individual shown on ibe Contractor's License) DEMINAL CNATURES Ate, 'QUIRED Richard D. Andrade 4/2n/n7 SIGNATURE PRINT NAME DATE .� Business Name: A 1'Z f A Addream 23000 NN 38 Ave. City/Seatdzip: _ _ , � F,L..,3.,3 0 5 4 , P?tonc: 305-688-4701 email: 0CE USE ONLY: • F.�'xP 13 ST. LUCIE COUNTY BUILDING & ZONING �u 2300 VIRGINIA AVENUE .z FORT PIERCE, FL 34962-5652 �ORtOA 561-462-1553 FILLED LANDS AFFIDAVIT I, the undersigned, am the owner of the following described property: 12 Palo Alto Spanish Lakes. I Part of 3414-501-1701-000/9 (Tax ID/Legal description/Address) for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number , I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely ffected. I further acknowledge that in granting this permit for the development of this roperty, St. Lucie County -is neither obliged nor liable to provide for, or maintain in a y form, adequate drainage off my property which will not adversely affect the immedia a community. Matthew Lyle Wynne Property Owner Name STATE OF FLORIDA, COUNTY OF St. Lucie Property Owner Signature Date ACKNOWLEDGED BEFORE ME THIS 2 0 t h DAY OF April , 20_Q3 BY Matthew Lyle Wynne HO IS PERSONALLY KNOWN TO ME HO HAS PRODUCED AS IDENTIFICATION. Q SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY NOTARY PUBLIC TITLE SUSAN MABEE k, MY COMMISSION # DD 630093 �= EXPIR58: February 23, 2011 Bonded7hruNofarypublkUndr3m6rs COMMISSION NUMBER (SEAL) Property Appraiser - St.Lucie Cod-;--- 7, FL Page 1 of 1 PROPERTY RECORD CARD Wynne Building Corp Record: 1 of 6 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification Site Address: 7950 S US HWY 1 ParcellD: 3414-501-1701-000-9 Sec/Town/Range: 26 :36S :40E Account #: 41242 y Map ID: 34/26N Land Use: HTLS MTLS Zoning: CG City/Cnty: ST. LUCIE COUNTY Ownership and Mailing Legal Description Owner: Wynne Building Corp ST LUCIE GARDENS 26 36 40 BLKS 1AND 2 LYG ELY OF US #1 Address: 12804 SW 122nd Ave R/W-LESS RDRS/W- (MAP 34/26N) (277.43 AC) Miami FL 33186-6203 Sales Information Assessment Final Total Land and Building Date Price Code Deed Book/Page 2006 Val: 41222800 Land Value: 36385500 Acres: 11.84 1/1/1900 0 / Assessed: 41222800 Building Value: 4837300 Ag.Credit: 0 Finished Area: 74525 SgFt Exempt: 0 Taxable: 41222800 TotalTax: 825288.71 BUILDING INFORMATION No Image Available Exterior Features View: - RoofCover: - RoofStruct: - ExtType: MHPK - MH Parks YearBlt: 1987 Frame: - Grade: C - C EffYrBlt: 1987 PrimeWall: - StoryHght: 0010 - 1 Story No.Units: SecWall: - Interior Features Bed Rooms: 1387 Electric: - PrmintWall: - FullBath: 0 HeatType: AvgHt/FI: 1/2Bath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth 1 3900-HTLS MTLS XCS -Sq Feet 347500 2 3900-HTLS MTLS 130 -Site 1387 3 3900-HTLS MTLS XCS -Sq Feet 168035 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/prc.asp?prclid=341450117010009 4/24/2007 Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucleco.gov/ce Date: 24 April 2007 Receipt #: 0000053412 Job Address: 12 PALO ALTO 'ermit Number: SLC- 0704-0441 Received By: goycochb Amount: $250.00 Paid With: CK �redit Card Number: Check Number: 028276 Paid By: WYNNE DEVELOPMENT Sign: Code Compliance Division Review Comments 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucleco.gov/ce PROPERTY INFORMATION Address: 12 PALO ALTO Unit # City / State / Zip: PSL Parcel # : 3414-501-1701-000/0 Zoning: RMH-5 APPLICATION INFORMATION Permit Number: 0704-0441 Activity Type: New Permit Type Building Residential (SFR) CONTRACTOR INFORMATION Contractor Name: 10 FL 34952 Jurisdiction: St. Lucie County Lot #: Block: Business Name: 6WYNNE DEVELOPMENT CORP Business Addr: 8000 S US 1 City / State / Zip: PORT ST LUCIE, FL 34952 Page 1 Owner(s): WYNNE BUILDING CORP Application Type: Master Permit w/subs Other Activity: Stories: 1 Automatic Sprinkler System? ❑ Fax Number 772-878-7656 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Complete Date Released Documents Missing Pending 05/07/2007 1 Comment NEED TO BRING IN WITH PICK UP A RECORDED NOC Front Counter Review Complete Beatriz Goycochea 04/24/2007 04/24/2007 Notified for Pickup Pending Olt Q Q R. Plans Examiner Review Incomplete Joe Cicio 05/14/2007 05/14/2007 1 Comment BOTH ENERGY CALCS MUST BE DESIGNED TO THE CURRENT 4.5 vsn. AND BEAR THE ORIGINAL SIGNATURES OF THE PREPARER AND THE CONTRACTOR.THIS MUST INCLUDE THE E.P.L.CARDS' CONTRACTOR TO PROVIDE PROPER DOCUMENTATION THAT THE SUMMER AND WINTER AS -BUILT ORIENTATIONS ARE CORRECT ` A-C SIZING CALCULATIONS MUST BE SITE -SPECIFIC TO THE STRUCTURE BEING PERMITTED 05/14/2007 2 Comment ENGINEER TO SUPPLY A SIGNED AND SEALED LETTER THAT THE MASTER PLAN ON FILE COMPLIES WITH THE 2006 SUPPLEMENTS OF THE 2004 F.B.C. 05/14/2007 3 Comment SOFFITS MUST BE DESIGNED PER R-703.1.1 FOR THE LOADS SPECIFIED IN R-301.2[2] 05/14/2007 4 Comment Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stlucieco.gov/ce 05/14/2007 5 05/14/2007 6 05/14/2007 7 Review Comments TRUSS PLANS MUST BE UP -DATED TO THE 2006 Page 2 THE 2004 F.B.C. I see R-802.1.6.1 for plan requirements] SIGNED AND SEALED PER 61g-15 AND REVIEWED AND APPROVED BY E.O.R. Comment 13a5-ocs IS AN INCORRECT CONSTRUCTION NUMBER AS STATED IN THE MANUAL J CALCS FOR THE O.S.WALLS ` IF USING FI-FOIL AS STATED, PLS REVISE THE NUMBER [ POSSIBLE CUSTOM WALL] see fi-foil specs for designs Comment CONTRACTOR TO NOTE THE ORIENTATION OF THE HOME ON THE SURVEYS[ PLOT PLANS] Comment COMMENTS MAILED TO CONTRACTOR AS OF THIS DATE Zoning Review Complete Lydia Galbraith 05/07/2007 05/07/2007 TRANSMISSION VERIFICATION REPORT TIME 05/13/2007 20:33 NAME ST LUCIE CO FAX 7724625267 TEL 7724621735 SER.* BROL4J160710 DATE DIME 05/13 20:33 FAX NO./NAME 98787656 DURATION 00:00:31 PAGE(S) 02 RESULT OK MODE STANDARD ECM 11-2 Date 'FILE COPY' -f64o---A L it c-3 e 20'-0' to iquirements. > have T—O' O 14'—O' oncrete, and FIRST FLOOR PLAN e beams etc.. to. SCALE 1/q" = 1'—O" I. grout mix bottom chord a treated. or stud dimensions. AREA CALCULATIONS Bathroom for Living A/C = Entry = 1335 sq. 55 sq. ft. ft. Back Porch Total = 200 sq. ft. Garage = 314 sq. ft. Total Under Roof= 190-4 sq. Ft. THESE! PLANS AND ALL PROPOSED WORK ARE 8' BJECT TO ANY CORRECTIONS REQUI IED BY FIELD INSPECTORS THAT MAY NECESSARY IN ORDER TO OUR WITH ALL APPWCAR�R Q0.999e oc, 0/- 030-5, LUCIE C®U UILDINQ DIV RIEVI E] REVIEW E DATE o •O 0,LAN)f AND PERMIT MUS..'r KEPT ON JOB OR NO INSPECTION WILL BE MADE Ll 0 4/ ki S. FILF rnp, FORM 60OA-2004R EnemvGaune@ 4 5 FLORIDA ENERGY r EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: WYNNE SPANISH LAKES LAUREL Address: 12 Palo Alto City, State: PSL , FL Owner: Climate Zone: Central Builder: WYNNE Permitting Office: Permit Number: 0704-0441 Jurisdiction Number: 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit/Split Cap: 28.2 kBtu/hr 3. Number of units, if multi -family 1 - _ SEER: 13.00 4. Number of Bedrooms 2 _ _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) _ 1335 ft2 c. N/A _ 7. Glass typel and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a.(Sngle, U=1.3) 41.0 ft2 _ a. Electric Heat Pump/Split Cap: 26.0 kBtu/hr b. SHGC: _ HSPF: 7.70 (or Clear or Tint DEFAULT) 7b. (Clear)131.0 ft2 _ _ b. N/A 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 0.0(p) ft _ c. N/A b. N/A c. N/A _ _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 40.0 gallons a. Concrete, Ext Insul, Exterior R=4.1, 1056.0 ft2 _ _ EF: 0.95 b. Frame, Wood, Exterior R=11.0, 115.0 ft2 _ _ b. N/A c. N/A d. N/A _ _ c. Conservation credits e. N/A _ _ (HR-Heat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=d=9.0, 1335.0 ft2 15. HVAC credits b. N/A _ _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Unc. Ret: Unc. AH: Garage Sup. R=6.0, 76.0 ft MZ-C-Multizone cooling, b. N/A _ MZ-H-Multizone heating) Glass/Floor Area: 0.10 Total as -built points: 17485 PASS Total base points: 17621 I hereby certify that the plans and specifications covered by this calculation are in co pliance with the Florida Energy Code. PREPARED BY: DATE: % 7 I hereby certify that this buil ' g, s designed, is in compl'n with the Florida Energy QQe. © >77 OWNER/AGENT: DATE: / Review of the plans and specifications covered by this calculation indicates compliance wito the Florida Energy Code. Bejore construction is completed is building will be inspected for compliance with Section 553.908 ILDING OFFICIAL: TE: 1 Predominant glass type. For akkLik s type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCSB v4.5) FORM 60`0A-2004R EnergyGauge® 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1336.0 24.35 5851.0 1.Single,U=1.27,Clear NW 1.0 6.0 20.0 40.71 0.97 790.0 2.Single,U=1.27,Clear SW 1.0 6.0 40.0 56.97 0.96 2193.0 3.Single,U=1.27,Clear SE 11.0 7.8 41.0 61.05 0.46 1154.0 4.Single,U=1.27,Clear SE 1.0 6.0 30.0 61.05 0.96 1764.0 As -Built Total: 131.0 5901.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Ext Insul, Exterior 4.1 1056.0 0.48 506.9 Exterior 1171.0 1.90 2224.9 2. Frame, Wood, Exterior 11.0 115.0 1.90 218.5 Base Total: 1171.0 2224.9 As -Built Total: 1171.0 725.4 DOOR TYPES Area X BSPM = Points Type 12.ExteriorWood Area X SPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 21.0 4.80 100.8 Exterior 38.0 4.80 182.4 17.0 7.20 122.4 Base Total: 38.0 182.4 As -Built Total: 38.0 223.2 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1335.0 2.13 2843.6 1. Under Attic 19.0 1335.0 2.82 X 1.00 3764.7 Base Total: 1335.0 2843.6 As -Built Total: 1335.0 3764.7 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 167.5(p) -31.8 0.0 1. Slab -On -Grade Edge Insulation 0.0 167.5(p -31.90 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 0.0 INFILTRATION Area X BSPM = Points Area X SPM = Points 1335.0 14.31 19103.8 1335.0 14.31 19103.8 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60DA-2004R EnergyGauge@ 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:,, FL, PERMIT #: BASE AS -BUILT Summer Base Points: 30205.7 Summer As -Built Points: 29718.1 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 28200btuh ,SEER/EFF(13.0) Ducts: Unc(S),Unc(R),Gar(AH),R6.0(INS) 29718 1.00 (1.09 x 1.150 x 1.00) 0.260 1.000 9658.8 30205.7 0.3250 9816.9 29718.1 1.00 1.250 0.260 1.000 9658.8 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 FORM 60bA-2004R �� _ � EnergyGaugeO 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1335.0 9.11 2189.0 1.Single,U=1.27,Clear NW 1.0 6.0 20.0 14.71 1.00 293.0 2.Single,U=1.27,Clear SW 1.0 6.0 40.0 11.35 1.01 458.0 3.Single,U=1.27,Clear SE 11.0 7.8 41.0 10.35 1.67 709.0 4.Single,U=1.27,Clear SE 1.0 6.0 30.0 10.35 1.02 317.0 As -Built Total: 131.0 1777.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Ext Insul, Exterior 4.1 1056.0 2.36 2492.2 Exterior 1171.0 2.00 2342.0 2. Frame, Wood, Exterior 11.0 115.0 2.00 230.0 Base Total: 1171.0 2342.0 As -Built Total: 1171.0 2722.2 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 21.0 5.10 107.1 Exterior 38.0 5.10 193.8 2.Exterior Wood 17.0 7.60 129.2 Base Total: 38.0 193.8 As -Built Total: 38.0 236.3 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1335.0 0.64 854.4 1. Under Attic 19.0 1335.0 0.87 X 1.00 1161.4 Base Total: 1335.0 854.4 As -Built Total: 1335.0 1161.4 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 167.5(p) -1.9 0.0 1. Slab -On -Grade Edge Insulation 0.0 167.5(p 2.50 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 0.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1335.0 -0.28 -373.8 1335.0 -0.28 -373.8 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 FORM 60dA-2004R EnergyGauge@ 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT Winter Base Points: 5205.4 Winter As -Built Points: 5523.1 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 26000 btuh ,EFF(7.7) Ducts: Unc(S),Unc(R),Gar(AH),R6.0 5205.4 0.5640 2883.8 5523.1 1.000 (1.078 x 1.160 x 1.00) 0.443 5523.1 1.00 1.250 0.443 1.000 1.000 3061.3 3061.3 EnergyGauge'rm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 600A-2004R l , EnergyGauge@ 4.5 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2460.00 4920.0 40.0 0.95 2 1.00 2382.32 1.00 4764.6 As -Built Total: 4764.6 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 9817 2884 4920 17621 1 9659 3061 4765 17485 PASS EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FOkm 60OA-2004R 1 EnergyGauge@ 4.5 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1 /2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration regts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 85.7 The higher the score, the more efficient the home. FL, 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit/Split Cap: 28.2 kBtu/hr 3. Number of units, if multi -family 1 _ _ SEER: 13.00 4. Number of Bedrooms 2 _ b. N/A _ 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) 1335 ft2 c. N/A 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) _ a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a.(Sngle, U=1.3) 41.0 ft2 _ a. Electric Heat Pump/Split Cap: 26.0 kBtu/hr b. SHGC: _ HSPF: 7.70 (or Clear or Tint DEFAULT) 7b. (Clear) 131.0 ft2 _ b. N/A _ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 0.0(p) ft _ c. N/A b. N/A c. N/A _ _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 40.0 gallons a. Concrete, Ext Insul, Exterior R=4.1, 1056.0 ft2 _ _ EF: 0.95 b. Frame, Wood, Exterior R=I 1.0, 115.0 ft2 _ b. N/A _ c. N/A d. N/A _ _ c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=19.0, 1335.0 ft2 _ 15. HVAC credits b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, _ c. N/A _ HF-Whole house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Unc. Ret: Unc. AH: Garage Sup. R=6.0, 76.0 ft _ MZ-C-Multizone cooling, b. N/A _ MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy savin eatures which will be installed (or exceeded) ..yyo4� STAT�o in this home before final inspection. a se, a new EPL Display Card will be completed based on installed Code com ea es. ' / Builder Signature: Date: , ��r� `1 / / 0-7 a alkyl = Address of New Home: 1O�i / Lj l D ! �fl City/FL Zip: ��� y� c - 4 ! r� OD WE� *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStarTudesignation), your home may qualms for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areas see Summer & Winter Glass output on S�B ages 2&4. $nergyGauge® (Version: WE RC v4.5) Project Summary Job: - - wrightsoft' Date: 5110/07 mcdgftchalke Entire House By: PZ COMFORT CONTROL. OF SLC, INC. Pro'ect Information For: WYNNE CORP. SPANISH LAKES "LAUREL", FL Notes: 2007/13.0 Design Information Weather: Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 19641 Btuh Ducts 1917 Btuh Central vent (21 cfm) 658 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 22215 Btuh Infiltration Fort Pierce, FL, US Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ft2) 1335 1335 Volume (ft3) 10676 10676 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 80 41 Heating Equipment Summary Make Ruud Trade Zephyr 13PJA Series - ICECO Model 13PJA30 Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 7.7 HSPF 26000 Btuh @ 470F 25 OF 940 cfm 0.044 cfm/Btuh 0.00 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative Humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 19654 Btuh Ducts 2307 Btuh Central vent (21 cfm) 352 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 21198 Btuh Latent Cooling Equipment Load Sizing Structure 2109 Btuh Ducts 672 Btuh Central vent (21 cfm) 892 Btuh Equipment latent load 3673 Btuh Equipment total load 24870 Btuh Req. total capacity at 0.70 SHR 2.5 ton Cooling Equipment Summary Make Ruud Trade Zephyr 13PJA Series - ICECO Cond 13PJA30 Coil UBHK-21+RCHJ-36A1 Efficiency 13 SEER Sensible cooling 19740 Btuh Latent cooling 8460 Btuh Total cooling 28200 Btuh Actual air flow 940 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio r 0.86 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. vrio0 '1t50'ft Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 ACCA C:Wy Documents\Wrightsoft HVAC\Office Files\Misc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 1 Load Short Form Job: - wrightsoft- Date: 5/10107 the d®hchoke Entire House By: pz COMFORT CONTROL. OF SLC, INC. Project Information For: WYNNE CORP. SPANISH LAKES "LAUREL", FL Design Information Htg CIg Infiltration Outside db (OF) 42 90 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TD (°F) 28 15 Fireplaces 0 Daily range - L Inside humidity (%) - 50 Moisture difference (gr/lb) - 61 HEATING EQUIPMENT Make Ruud Trade Zephyr 13PJA Series - ICECO Model 13PJA30 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 7.7 HSPF 26000 Btuh @ 470F 25 OF 940 cfm 0.044 cfm/Btuh 0.00 in H2O COOLING EQUIPMENT Make Ruud Trade Zephyr 13PJA Series - ICECO Cond 13PJA30 Coil UBHK-21+RCHJ-36A1 Efficiency 13 SEER Sensible cooling 19740 Btuh Latent cooling 8460 Btuh Total cooling 28200 Btuh Actual air flow 940 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio 0.86 ROOM NAME Area (ft2) Htg load (Btuh) . Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) FOYER 78 1781 969 78 41 2ND BDRM 188 3238 4030 141 172 BATH 50 550 301 24 13 HALL TO BATH 17 25 45 1 2 DINING/GREAT RM 513 7533 5948 328 255 MASTER BDRM ,-.224 4858 4955 212 212 MASTER CLOSET 63 95 171 4 7 MASTER SINK AREA 36 529 264 23 11 MASTER BATH 49 722 360 31 15 LAUNDRY v l'TAI r-�1 46 7A 1381 oAG 1930 anon -60 07 83 1 Ann n1 1 VrICIV r-F . Q'YJ Printout certified by ACCA to meet all requirements of Manual J 8th Ed. vriightsoft Right -Suite Residential 6.0.95 RSR21055 ACCA C:wly Documents\Wrightsoft HVAC%Office Fileswlisc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M i 2007-Jun-11 10:17:45 Page 1 Entire House 1335 21558 21961 940 940 Other equip loads 658 352 Equip. @ 0.95 RSM 21198 Latent cooling 3673 TnTAIC .444 nAo7n non l Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrIghtsoft Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 ACCP. C:WIy Documents\Wrightsoft HVAMOfoe FilesWlisc BuildeAWYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 2 - + wrig.''°°`�?°�ht a- Right-J Worksheet Entire House COMFORT CONTROL OF SLC, INC. Job: Date: 5110/07 By: pz 1 Room name Entire House FOYER 2 Exposed wall 167.5 ft 16.0 ft 3 Ceiling height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 6.5 x 12.0 ft 5 Room area 1334.5 ft? 78.0 ftz Ty Construction LI-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-°F) (131:uh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A - 0.116 n 3.25 3.09 1208 1056 3430 3258 44 23 75 71 1A-clomd 1.270 a 35.56 91.12 41 41 1458 1426 0 0 0 0 1A-clom 1.270 a 35.56 91.12 30 0 1067 2734 0 0 0 0 1A-clom .1.270 s ' 35.56 37.88 40 40 1422 1391 0 0 0 0 11 1A-clom 1.270 w 35.56 91.12 20, 0 711 1822' 0 0 0 0 11J0 0.600 n 16.80 17..40 21 21 353 365 21 21 353 365 V�J �D 126-0sw 0.097 n 2.91 2.58 132 115 335 297 84 84 244 217 11 DO 0.390 n 11.70 11.31 17 17 199 192 0 0 0 0 C 166-19ad 0.049 - 1.37 2.57 1335 1335 1831 3433 78 70. 107 201 F 22A-vph 1.358 - 38.02 0.00 r 308 168 6369 0 16 16 608 0 6 c) AED excursion 0 -51 Envelope loss/gain 17175 14918 1387 803 12 a) Infiltration 2466 675 236 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances @ 1200 3 3600 0 0 Subtotal (lines 6 to 13) 19641 19654 1623 867 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 19641 19654 1623 867 15 Duct loads 10% 12% 1917 2307 10% 12% 158 102 Total room load 21558 21961 1781 969 Air required (cfm) 1 9401 940 78 41 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsolrC Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 ACCla C:\My Documents\Wrightsoft HVAC\Office Files\Misc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 1 wrighht�soRight-J Worksheet Entire House COMFORT CONTROL OF SLC, INC. Job: Date: 5110107 By: pz 1 Room name 2ND BDRM BATH 2 Exposed wall 26.0 ft 5.5 ft 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 12.5 x 15.0 ft 5.5 x 9.0 ft 5 Room area 187.5 ft2 49.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 51A r0.116 . n. . ' 3:25 3:09 208 188. 611 `:> 580 44 44 : ' .143 136; IA-clomd 1-270 e . 35.56 -=91.12 •p 0' ::Q 0 0 0 .. .p p 1A,clom 1.270 e : ., 35:56 ,. "81.12 Q 0 .' 0 •' 0 0 0 .: Q .' . 0: 1A cl om 1.270 s ; 35.56 37.88 . 0 0 U 0 0. ' . 0 0 0 1.1 IA-o1om 1:270 , w 35.56 . 91 12 ':20 :' 0 711 .,.. 1822.,.: 0 '' 0 11JO,. 0.600 ..n 16:80. ' "17:40 ' . 0.. .. 0 .. p, ._ p 0 ..0 6 0 yJ 12B-0sw 0.097 n 2.91 2.58 0 0 0 0 0 0 0 0 t—D 11 DO 0.390 n 11.70 11.31. 0 0 0 0 0 0 0 0 C 16B=19ad . 0:049 - 1::37 2.57; 188 -188 257 ': - .482 .: 50 5U - 68 - 127 F 22A-vph 1.358. - 38.02 0.00, 42 26 989 0 2 6 209 0F. 6 c) AED excursion 617 -16 Envelope loss/dain 2568 3502 420 247 12 a) Infiltration 383 105 81 22 . b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 1 2951 3607 501 269 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2951 3607 501 269 15 Duct loads 10% 12% 288 423 10% 12% 49 32 Total room load 3238 4030 550 301 Air required (cfm) 1 1 141 1721 1 1 24 13 _ Printout certified by ACCA to meet all requirements of Manual J 8th Ed. c wr�ghtsoft Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 Ar—Z Pk C:1My Documents\Wrightsoft HVAC\Office Files\Misc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 2 -�- wrightssoftft Right-J Worksheet Job: &mrWEntire House Date: 5/10107 By: pz COMFORT CONTROL OF SLC, INC. 1 Room name HALL TO BATH DINING/GREAT RM 2 Exposed wall 0.0 ft 45.0 ft 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat1cool 4 Room dimensions 5.5 x 3.0 ft 25.0 x 20.5 ft 5 Room area 16.5 ft2 512.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft� Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or Perimeter pemeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A 0.118 n 3.25 . 3.09; 0, 0 0 0 ! 360 279 908 861 IA-c1omd 1.270 a 35.56 91.12 0. 0 0 0 ' 41 I 41 1458 1426 IA-c1om 1.270. a 35.56 91.12 0 0 0 0 0_ 0 0' 0. 1A-c1om 1.270 s 35.56 37.88 '0. 0 0 0 40 40 1422 1391 11 IA-c1om 1.270 w 35.56 91A2 0 .0 0 0 0 O 0 0 11.10 0.600 n 1680 17.40. '0 0_ 0 0 0 0 0 0 VN 12B Osw 0.097 n 2.91 2.58 0 0 0 0 0 0 0 0 �D 11DO 0.390 n 11.70 11.31 0 0 0 0 0 0 0 0 C 16B-19ad 0.049 1.37 `257, .17 .17 23• . 42 513 5.13 703 1318 F 22A-vph 1.358 38.02 0.00 0 0 0 0 127 45 1711 0 6 c) AED excursion -2 -314 Envelope loss/gain 23 40 6201 4682 12 a) Infiltration 0 0 663' 181 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 23 40 6863 5323 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23 40 6863 5323 15 Duct loads 10% 12% 2 5 10% 12% 670 625 Total room load 25 45 1 7533 5948 Air required (cfm) 1 2 328 255 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr140"tsoi=t Right -Suite Residential.6.0.95 RSR21055 2007-Jun-11 10:17:45 AE& C:\My Documents\Wrightsoft HVAC\Office. Files\Mist Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 3 - wrightsoft- Right-J Worksheet Job: Entire House _ Date: 5110107 By: pz COMFORT CONTROL OF SLC, INC. 1 Room name HALL TO BATH DINING/GREAT RM 2 Exposed wall 0.0 It 45.0 ft - 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 5.5 x 3.0 ft 25.0 x 20.5 ft 5 Room area 16.5 ft2 512.5 W Ty Construction U-value Or HTM Area Load Area (ft-) Load number I (Btuh/ft2 °F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat Cool 6 51A 0.116 - n 3.25 . 3.09 0 0 0 0 360 .279 61 861 1A-61omd 1.270 a 35.56 91.12 0 0 0 0 : 41 41 .906 1458 ' 18426 1A-clom 1.270 a 35.56 - 9.1.12 01 0 0 0 0- 0 0; . 0. IA-ciom 1.276 s :35i56 :37.80 0. 0 0 . - 0 40 .40 1427 1391 11 1A-c1om 1:270 w. 35.56 :.91.12 0 0 6 0 0 0 0 0 11JO . 0.600 n'. '1680 17.40. 0 0 0 0 0 0 0 0 126-0sw 0.097 n 2.91 2.58 0 0 0 0 0 0 0 0 11 DO 0.390 n 11.70 11.31 0 0 0 0 0 0 0 0 C 166-19ad 0.049 - 1.37. - �--2.57: 17 17 -1 23::. 42 513 '5.13 703 1318 F 22A-vph 1.358 - 38.02 0.00 0 0 0 0 127 45 1711 0 6 C) AED excursion -2 -314 Envelope loss/gain 23 401 6201 4682 12 a) Infiltration 0 0 663 181 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 23 40 6863 5323 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 '14 Subtotal 23 40 6863 5323 15 Duct loads 10% 12% 2 5 10% 12% 670 625 Total room load 25 45 7533 5948 Air required (cfm) 1 2 328 255 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. c wr1140htsoft Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 AZUk C:WIy Documents\Wrightsoft HVAC\Office. Files\Misc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 3 wrightssoft- Right-J Worksheet Entire House COMFORT CONTROL OF SLC, INC. Job: Date: 5/10/07 By: pz 1 Room name 'MASTER BDRM MASTER CLOSET 2 Exposed wall 40.0 ft 0.0 ft 3 Ceiling height 8.0 ft heat1cool 8.0 ft heat/cool 4 Room dimensions 14.0 x 16.0 ft 9.0 x 7.0 ft 5 Room area 224.0 ft' 63.0 ft= Ty. Construction 0-value Or HTM Area (ft� Load Area (W) Load number I (Btuh/ft;`F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter- (ft) (Btuh Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A 0.116 . n 3.25 3.09 320 290 942 895 0 0 0 0 IA-clomd 1.270 a 35.56 91.12 0 0 0. 0 0 0 0 0 1A-c1om 1.270 a 35.56- 91.12 SO .0 1067 2734 0 . 0 0 0 1A-c1om 1:270 s 35.56..* 37.88 0 .`0 0 0 0 0 0 0 11 .IA-clom 1270 w 35.56 91.12 0 0" 0 0 0 0 .0 0 11JO 0:600 n 16:80 17AO 0 0 `0 0 .0 0 0 0 t--D 1213-0sw 0.097 n 2.91 2.58 0 0 0 0 0 0 0 0 11 DO 0.390 n 1 1.70 11.31 0 0 0 0 0 0 0 0 C 16B-Oad 0.049 . - 1.37 2.57: 224 - ' 224 -: :307 576 63 63 . . 86 162 F 22A-vph 1.358 - 38.02 0.00 100 4.0 1521 0 0. 0 0 0 6 . c) AED excursion 69 -9 Envelope loss/gain 3837 4273 86 153 12 a) Infiltration 589 161 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 4426 4434 86 153 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4426 4434 86 153 15 Duct loads 1 10% 12% 432 521 10% 12% 8 18 Total room load 4858 4955 95 171 Air required (cfm) 212 212 4 7 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. c wr�ghtsoft Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 ACUk C:WIy Documents\Wrightsoft HVAC10ffice Files\Misc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 4 n + wrigMT A+ 1 1 Righ" Worksheet ' Entire House. COMFORT CONTROL OF SLC, INC. Job: Date: 5110107 By: pz 1 Room name MASTER BDRM MASTER CLOSET 2 Exposed wall 40.0 It 0.0 ft 3 "Ceiling height 8.0 ft heab000l 8.0 ft heat/cool 4 Room dimensions 14.0 x 16.0 ft 9.0 x 7.0 ft 5 Room area 224.0 ft2 63.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft2) Load number I Btuh/ft;°F ( ) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 IV 51A 0.116 .<n ", 3.25.: 3.09 .320 290 942 895 .0 0 0 0 1A-clomd 1.270 e 35.56 91A2 0 0 0. 0 0 0 0 0 IA-clom 1.270 a ' 35:56 : 91:12 - `30 : .. ,0 1067 2734 0 " 0 - (Y .0 1A-cl om 1.270 s - 35:56 : 37.88 0 ' - 0 0 0 0 .0 ,0 0 11 1A-clom 1.270 w: 3556 t 91.12 0 U .0 0 p 0 0 p 11JO 0:600 n 16.80 .17:40 0 p 0 0 p. yJ 12B-0sw 0.097 n 2.91 2.58 0 0 0 0 0 0 0 0 �D 11D0 0.390 n 11.70 11.31 0 0 0 0 0 0 0 0 C 166-19ad . 0,049 ::- 1.37 2.57: •:. 224 .. .: =4 -" ' .307 576 63 63 9 .86 -162 F 22A-vph 1.358 .- 38.02 0.00 .100 40 .1521 0 0. 0 0 0 6 c) AED excursion 69 -9 Envelope loss/gain - 3837 4273 86 153 12 a) Infiltration 589 /161 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 p Appliances @ 1200 0 0 0 1 p Subtotal (lines 6 to 13) 4426 4434 86 153 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4426 4434 86 153 15 Duct loads 10% 12% 432 521 10% 12% 8 18 Total room load 4858 4955 95 171 Air required (cfm) 212 212 4 1. 7 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrrtgf-rttsOftt Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 AC6K CAMy DocumentsUrightsoft HVAC\Office Files\Misc BuildeAVVYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 4 i 1 -+* wrightso� Right-J Worksheet Job: Entire House Date: 5/10107 COMFORT CONTROL OF SLC, INC. By: PZ 1 Room name MASTER SINK AREA 2 Exposed wall 5.5 ft MASTER BATH 3 Ceiling height 8.0 ft heaUcool 7.5 ft 4 Room dimensions 8.0 ft heaUcool 5 Room area 35.8 ft5.5 x 6.5 ft 2 6.5 x 7.5 ft 2 48.8 ft Ty Construction U-value Or HTM Area (W) Load Area (ftz) Load number (Btuh/ftk-"F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A . 0116 n 3.25 309 4444'1A=06rnd ,1270 .,e 35.56 91:12 , 0 143, `•: 136 60 60 195 1A clom- 1 270 a 35c56 91.12 0 p - 0 0 0 0 1A c1om: 1.27 s` 95:56 , 37,c88 : 0 0 0 0 0 0 0 ' 0 11 1A-clorri; 1270 ',ini :35.56 9t':]2 "<0 p 0 0 0 'p 0 11J0 0,600 :n' ; I6.80 . 17:40 ..:a 0, 0 0 �D 0.097 n 2.91 2.58 0 0 0 0 0 p 16B 0.390 n 11.70 11.31 0 0 0 0 0 0 0 F 16B-19ad :. '0 049 1:37. , •, .2.57 x' 36 i :: 36 .. 0 0 0 49 92 `: _ 49 :,..:r49 • 67 :125: F 22A vph 1 356 - 38 02 0,00 2 6 209 p 4 8 285 0 _ ._l SCZ y - 6 c) AED excursion -14 -19 Envelope losstgain 401 214 547 292 12 a) Infiltration b) Room ventilation 810 0 110 30 0 0 13 Internal gains: Occupants @ 230 0 0 0 Appliances @ 1200 0 0 0 0 0 Subtotal (lines 6 to 13) 482 236 657 322 Less external load 0 0 Less transfer 0 0 0 0 Redistribution / 0 0 0 0 14 Subtotal 15 Duct loads o 10 /0 c 12 /0 482 47 236 0 657 0 322 28 10% 12% 64 38 Total room load Air required (cfm) 529 264 722 360 23 11 31 15 Printout certified by ACCA to meet all requirements of Manual J 8th Ed Whgl-1t5oft Right -Suite Residential 6.0.95 RSR21055 ACM C:WIy DocumentslWrightsoft HVAC\Office Files\Misc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M 2007-Jun 11 10:1Paggee 5 5 ' wrightt Lftft- Right-J Worksheet Job: Entire House Date: 5/10107 COMFORT CONTROL OF SLC, INC. By: pZ 1 Room name 2 Exposed wall AU LAUNDRY KITCHEN 3 Ceiling height 8.0 ft ft 8.5 ft 4 Room dimensions heaVcool 8.0 . ft heaticool 5 Room area 45.5 ft 6.5 = x 7.0 ft x 7.0 ft 210.5 73.5 ft Ty Construction number U-value (Btuh/ft2 -F) Or HTM (Btuh/ft� Area (ft2) or Load Area et Load perimeter (ft) (Btuh) or ped r (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A- 1A clomd . 0.1.16 1.270 n e ` _3.25 35:5fi - „ 9:1.12 :. 60 60 : 195 -185..: 68_ s6 221 1Ac1om 1.270 :e 35,56 - :91.12 0 ;'. p , 0 0 0 - . ': 0 - t) . 0 11 1Ac1om 1Ac1om. 1.270 s `; 35.56 AS 0 0 0 0 0. `.;0 p 0 0 G 11J0 .' 1.216 0:600 .w . -n 3&s6 16:80 '91'.12 :17.40 ;0 0 p 0 0..'.. 0 0 0 : 0. a p tAJ �p 126 Osw 0.097 .: n 2.91 2.58 48 0 31 0 90 p 0 0 C 11 DO 166-19ad 0.390 0.049 n 11.70 :: 11.31 ' ' 17, 17 199 80 192 0 0 0 0 0 0 0 F 22A-vph 1.358 -- - 1.37 38,02. :2.57 ; 0Ap : 46': 11 46 14 62"` 117 :.::.. 74' ; . 74 101 0 189 513 p 5 9 323 0 6 c) AED excursion -102 -158 Envelope losstgain 1060 473 645 241 12 a) Infiltration b) Room ventilation 1990 4 125 0 34 0 13 Internal gains: Occupants @ 230 Appliances @ 1200 0 1 0 1200 0 2 0 2400 Subtotal (lines 6 to 13) 1259 1727 no 2675 14 15 Less external load Less transfer Redistribution Subtotal Dud loads o 10 /a 0 120 0 0 0 125 123 0 0 0 172 203 10% 12% 0 0 0 770 75 0 0 0 2675 314 Total room load Air required (cfm) 1381 60 1930 83737 845 2989 128 Printout certified by ACCA to meet all requirements of Manual J 8th Ed 1 wr�ghtsoft Right -Suite Residential 6.0.95 RSR21055 C:Wty DocumentslWrightsoft HVAC10ffce FilesWlisc BuilderXWYNNE SPANISH LAKES LAUREL.rsr Calc = M 2007-Jun-11 10:17:45 Page 6 I S. gieCo.F Date �V Init proved Specific Purpose. Survey . Location Of Formboard For: WYNNE BUILDING CORD STREET ADDRESS 12 PALO ALTO DESCRIPTION (olcu4PIED) Being all of 12 PALO ALTO, of the unrecorded plat of SPANISH LAKES PHASE I, of St. Lucie County, 0 10 20 Florida. � 6===I l EXISTING MOBILE HOME — GRAPHIC SCALE IN FEET EAST I �104.00 LEGEND & ABBREVIATIONS 0.00' e ASSUMED �_ CONIC. DENOTES CONCRETE P.B. DENOTES PLAT BOOK P.C,p, DENOTES PERMANENT CONTROL POINT C.M. DENOTES CONCRETE MONUMENT P DENOTES PLAT DATA O.R. DENOTES OFFICIAL RECORDS BOOK 32 00• 16.00• any �C; DENOTES CALCULATED FROM FIELD MEASUREMENTS IR & C DENOTES IRON ROD & CAP O 0 145- 510.00• wO °� IC DENOTES PROPERTY LINE PG. DENOTES PAGE M) DENOTES MEASURED DATA COR. DENOTES CORNER O 0 Qj 0 ID DENOTES IDENTIFICATION NUMBER P.O.B. DENOTES POINT OF BEGINNING DENOTES FLOW LINE P.O.0 DENOTES POINT OF COMMENCEMENT TOB f- J Q, Q � l7 o 12 I' O DENOTES TOP OF BANK I.P. DENOTES IRON PIPE TYP. DENOTES TYPICAL I.R. DENOTES IRON ROD ¢ �I �. N L FND. DENOTES FOUND U.E. DENOTES UTILITY EASEMENT L.B. DENOTES LICENSED BUSINESS P.I. DENOTES POINT OF INTERSECTION < Oa a = m O ° EXISTING FORMBOARD CELE2'07� V=(AVERAGE _ O.H.U. DENOTES OVERHEAD UTILITIES P.L.S.DENOTES PROFESSIONAL LAND SURVEYOR ® DENOTES WATER METER DENOTES ELEVATION (TYPICAL) Q a 9r20� HEIGHT ABOVE EDGE OF PAVEMENT) -- 0 GENERAL NOTES O Z NOki o Z 1. The bearings shown hereon are referenced to the centerline of Palo Alto 32.00'—� : ': 0 1s_oo' having an Assumed bearing of NORTH, according to the Unrecorded plat of SPANISH LAKES PHASE I, of St. Lucie County, Florida. 2. All above ground fixed improvements, if any, have been located and shown hereon. EAST 104.00' 3. Underground utilities and utility services have not been located on this survey. EXISTING MOBILE HOME -4. Flood Note: By graphic plotting only, this property is in Zone X., according t• the Flood Insurance Rate Map, Community Panel No. 12111CO280 F , effective date May 4, 1989. The exact designation can only be determined by an elevation certificate. I UP 5. Reproductions of this map are not valid without the signature and original raised seal (OCCUPIED) of a Florida Licensed Surveyor & Mapper. 6. Lands shown hereon were not abstracted by this office for rights —of —way, easements of record, ownership, abandonment's deed restrictions, or Murphy Act Deeds. 7. The last date of field work was June 21, 2007. 8. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 9. The purpose of this map is to show the relationship of new structure to the existing structures, and the relationship of the average height of new structure to the Centerline of road. 10. Elevations shown hereon are in feet and are based upon assumed datum. CERTIFIED TO: Wynne Building Corp L Charles Amold Date Signed Professional Surveyor & Mapper Florida Certificate No. 4971