Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE FILED: �4. N -01 , I PLAN REVIEW FEE: RECEIPT NO.: ��L'I 04 PERMIT NUMBER: c704.04 ` 2' - CONCURRENCY FEE: RECEIPT NO.: CERT. CAP. NO.: ALL INFO MUST BE COMPLETE u FILLED IN TO BE ACCEPTED 1� N� COG SCANNED ST. LUCIE COUNTY PUBLIC WORKS � BY BUILDING & ZONING DEPARTMENT ��• �UCI@ Cpllfit 2300 VIRGINIA AVENUE .��CR,�Q Y FORT PIERCE, FL 34982-5652 772-462-1553 APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 76 Mediterranean East 2. S/D NAME: Spanish Lakes I SITE PLAN NAME: 3. PROPERTY TAX ID #: Part of 3414-501-1701-000/9 v 4. LEGAL DESCRIPTION (attach extra sheets if necessary): Section 26, Township 36S and Range 40E 5. PLAT. 6. PAGE 7. BLOCK BOOK NO. NO. -8. LOT NO. 9. PARCEL SIZE: ACRES/SQ FT. LOT DIMENSIONS -90' x110' 12, 10. DESCRIPTION OF CONSTRUCTION PROJECTOR WORK ACTIVITY: s; ngl P Family Residence F� Laurel Model Left MP#0601-0304 Replacement 11. ' SETBACKS (ACTUAL) FRONT: BACK: RIGHT t' LEFT 351 19, SIDE 9' SIDE: 71 12. TYPE OF CONSTRUCTION (Check all appropriate ►�1n 5 boxes) - PCY NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION [K] RESIDENTIAL [ ] COMMERCIAL [ ] INDUSTRIAL [ ] OTHER (SPECIFY) 13. DESCRIPTION OF PROPOSED USE: Residence 14. Sq. Ft./CONSTRUCTION: 1904 15. Sq. Ft. 1st Floor: 16. VALUE OF CONSTRUCTION: $ $ 81, 8 7 2.0 0 "lb y a O�? /Z The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify th indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $25a or more, a RECORDED Notice of Commencement must be submitted with this application. .z SLCCDV Form No.: 001-02 OWNER INFORMATION: NAME: Wynne Building Corporation ADDRESS: 8Clnn S _ Ug 4l, St . 4-402 P,80LA c�Z 1221AA ft.J-0 CITY. Pay-t—St Lucie m%QM, STATE: FL ZIP PHONE (DAYTIME): (7721 878-5513 IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): CONTRACTOR INFORMATION V ST. of FL REGJCERT #: C G C 0 3 5 9 9 ST. LUCIE COUNTY CERT #: 08898 BUSINESS NAME: Wynne Development Corporation QUALIFIERS NAME: Matthew Lyle Wynne ADDRESS: 8000 S. US #1, Suite #402 CITY. Port St. Lucie STATE: FL ZIP 34952 PHONE (DAYTIME): (772) 878-5513 FAX No. 772-878-7656 ARCHIT/ENGINEER: Braden & Braden ADDRESS: 417 Coconut Ave. CITY: Stuart _- STATE: >±L ZIP 346 PHONE (DAYTIME): (7 7 2) - 2 8 7- 8 2 5 8 BONDING COMPANY: ADDRESS: CITY: STATE: ZIP MORTGAGE LENDER: ADDRESS: CITY: STATE: ZIP IMPORTANT NOTICE: When a permit is issued and it is not picked up within Q days after notification it will be voided and returned to you by mail. N` CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, -SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, -AND AIR CONDITIONERS, ETC., not otherwise included with this building permit application. The following -building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR ENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLI ANT: AS THE APPLICANT FOR THIS BUILDING ERMIT, IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACH ENT; AS A CONDITION OF THIS PERMIT YOU PROMISE IN GOOD FAITH TO DELIVER A C PY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PR PERTY IS SUBJECT TO ATTACHMENT. OWNER'S AFFID VIT: I certify that all the foregoing information is u ate and that all work will be done in compliance with all applicable laws regulating construc nd zoning. OWNER/CON C OR SIGNATURE CON CTOR SIGNATURE STATE OF FLORIDA COUNTYOF St. Lucie The foregoing instrument was acknowledged this 20_0_7, by _ Matetf%eewme parSonaUy1nawP_10 Ly� od me r who has ced -'--? s as identification. of Type or Print Name of Notary Notary Public Title Co SUSANMAGEE t MY COMMISSION # DD 630093 (seal) EXPIRES: February 23, 2011 8ondAThtuNoWyPubuoUnderklem _ STATE OF FLORIDA COUNTY OF St Lucie The foregoing instrument was acknowledged before me this 2 n i- gay of .20 07 , by Matthew Lyle Wynne o is personally known e or 7w/has prod ea as-roennnoai ignature of No Type of Print Name of Notary Notary Public Title Commissi er SUSAN MAGEE '*'+= MY COMMISSION # DD 630093 (seal'' ' t` EXPIRES: February 23, 2011 ) F4a aohded 9T ru NafAry POYO Undarwi ter, NOTE: TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THIS APPLICATION. • F* BP #: b-7QU - C)L414Z SECTION: 2,6 TOWNSHIP: �65 RANGE: ' roC MAP NO.: tw-b ZONING: •� LAND'USE:� LOT CVG %: 62- TAZ NO.: FLOOD ZONE: FIRM MAP #: 1ST FLR ELV: MAX HGT: CST TYPE: OCCP TYPE: MAX. OCCP: # OF FLRS: WATER: , SEWER: SPRINKLERS STORMWATE R LOT OF REC (befr 1190) LOT OF REC (aftr 1/90) LOT SPLIT REQ'D LOT SPLIT APPRV'D DECAL NUMBER LIBRARY IMPACT FEE PARKS IMPACT FEE PERMIT FEE j REPORT CODE 1['� 1 v PUBLIC BLDG IMPACT FEE HABITABALE AREA (RADON) RADON FEE ROAD�n� IMPACT ZONE . IJ GROSS ROAD IMPACT FEE DUE C7�< N TOTAL ROAD IMPACT FEE SGFiUUL CREDIT TOTAL IMPACT FEE SCHOOL L _ M A T 1 P C FEE POLICE FEE FIRE FEE MISC FEES: TOTAL oQ POLICE/FIRE/ MISC. FEES Y N EGeC */C-.. ) pCD �J ADDITIONAL SPECIFY: TOTAL ALL PERMITS FEES REQ'D !!�Cyi REVIEWS ZONING ZONING PLANS 'VEGETATION SEA MANGROVE REVIEWED BY EXAMINING TURTLE, DATE COMPLETE INITIALS 1_�� FILE # 3045454 OR BOOK 2804 PAGE 2579, Recorded 04/24/2007 at 01•:27 PM r� NOTICE OF COMMENCEMENT PermitNo.O O—I :0 I a Tax ID#Part of 3414-501-1701-000/9 State Of CountyOf. St. Lucie THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Legal Description of property and street address, if available Section 26, Township 36S and Range 40E 76 Marlitrrranaan Fast Spanish Lakes I General description of improvements Single family residence Owner Address 8600 S U S # Suite #402, Port St Lucie, FL 34952 Ownces interest in site of improvement Fee Simple Fee Simple Title holder (if other than Address Contractor Wynne Develo ment' Cor o UOTI Phone# 772-878-5513 Address 8000 S.U.S.#1,Suite 0402,P FL 34952 Fax# 772-878-7656 Surety _ Address Amount of Bond S Phone Fax # Phone # Fax # Persons within the State of Florida designated by Ownerupon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7., Florida Statutes: Name Douglas Brantley, Man a er Phone#772-878-3011 Address 1 Silver Oak Drives p L, FL-34952 Fax# 772-340-0394 In addition to himself, owner designates of (Phone # Fax # ) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b , rida Statutes. Expiration date of notice of commencement is one year from the date of recording unless a dif date is specified. STATE OF FLORIDA, COUNTY OF 4 t .Lucie Acknowledged before me this20±_hday of Apr i 1 200 7�by=siGNATVUR:!4 y ]rnowa to a or who has produced as identification. (seal) E OF EUSM MApEE TYPE OR PRINT NAME OF NOTARY M1' C0LUIS iION A, OD M93 i r EXPIREtI:41ITUI�u23,2011 NOTARY PUBLIC TITLE owd,dinu N*q Pub W"?, COMMISSION NUMBER cST-11.iF OF FLORIDA S . LUCIE COUNTY THIS Tf)(:tRTI!'Ylt':r/, ollvtS„ �> t95:J ' h�ir•! D u�)ri.y :C i C4.s�;Ot ii rt?1S,j( Sql�S ��•S Sl'f'tl i Si � 3VY.l... 11 4:+e1iJ `� "���`ti.f•'r-. jai � ��•%a ris`:a RECEIVED V ICDEC 14 2007 HULIE • ' environa�cnt:al serviocs Public Works St. Lucie County, FL. Pre -Construction Termite 4rrleatment 1-800-285-7378 (596-1-OA(AD Property Information Builder/Contractor Treatment Date �� v� Time - Lot Block Name of Builder Subdivision Name Shell Contractor 79 Street Address (If known) J�yL ' Construction Type City IState zip onolithic ❑Floating/Stemwall []Patio Owner's Name (If known) ❑Entry ❑Driveway ❑Other: Product/Treatment Information Treatment Type: ❑ Underslab ❑ Patio/Driveway Final Wood Treatment ❑ Bait System ❑ Other Product: jPennethrin um Octaborate (Boracare) ❑ Cypermethrin ❑ Other: Concentration P /' Mixed Product Applied Square Feet Treated Linear Feet Treated a If this box is checked, then Final Perimeter treatment has been completed and the following statement is applicable: Certificate of Compliance: This building has received a complete treat en for the prevention of subterranean termites. This treatment is in accordance with the la d rules e ed by the Florida Department of Agriculture and Consumer Services. 0. Neel - Applicator's Name (please print) Ilel Ap icator's Signature HES-TE019 07/07 Hulett Environmental Services© 2007 CERTIFICATE OF OCCUPANCY This Certificate is issued pursuant to the requirements of the Florida Building Code certifying that at the time of issuance this structure was in compliance with the various ordinances of St. Lucie County regulating building construction or use. For the following: Building Permit No. - 0704-0442 Parcel/Folio Nbr: 3414-501-1701-000/9 Lot # Block: Subdivision: St Lucie Gardens S/D Occupancy: Residential - 1 & 2 family dwellings Building Address: 76 E MEDITERRANEAN BLVD Legal Description: ST LUCIE GARDENS 26 36 40 BLK 1 AND 2 LYG ELY OF US 1 R/W LESS RDR S/W SPANISH LAKES #1 Permit Job CONSTRUCTION OF SINGLE FAMILY RESIDENCE - LAUREL MODEL LEFT Description Permit Finaled: 12/13/2007 Contractor WYNNE MAT MEW L WYNNE DEVELOPMENT CORP (772) 878-5513 8000 S US 1 PORT ST LUCIE, FL 34952 Christopher Lestrange Building Official Thursday, December 13, 2007 Date Printed NOTE: This Certificate of Occupancy is issued to the above named, for building at the above named location only upon the express provision that the applicant will abide by and comply with all the conditions of the Zoning Ordinances and all Ordinances or Building Codes of Saint Lucie County pertaining to the erection, construction or remodeling of buildings or structures. This also certifies that the electrical wiring and/or equipment, and the plumbing work have been inspected and approved. The issuance of this Certificate grants permission to occupy and use the property described herein only for the use indicated. Any change in use will require a new Certificate of Occupancy. POST IN A CONSPICUOUS PLACE Code Compliance Division Ft. PiVirginia rce, i L 3498e INSPECTION CARD Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://st,lucleco.gov/ce Permit #: SLC- 0704-0442 Conf #: 730 Type: Building Residential (SFR) Issued 06/15/2007 Status: FIN Double Fee: No Job Location 76 E MEDITERRANEAN BLVD City: PORT ST LUCIE Jurisdiction: St. Lucie County Lot: Block: Parcel: 3414-501-1701-000/9 Subdiv: St Lucie Gardens S/D Flood: X Elev: Flood Map: 283F Job Description: CONSTRUCTION OF SINGLE FAMILY RESIDENCE - LAUREL MODEL LEFT Setbacks Left: 7.00 Right 9.00 Inspection Notes: EAST MED BLVD Front 35.00 Rear, 19.00 Contractor WYNNE MATTHEW L WYNNE DEVELOPMENT CORP (772) 878-5513 8000 S US 1 PORT ST LUCIE, FL 34952 Property Owner WYNNE BUILDING CORP (772) 878-5513 12804 SW 122ND AVE MIAMI, FL 33186 SUB -PERMITS Permit # Status PT Cert # DBA 0704-0442-01 FIN EP 4267 JOE'S ELECTRIC OF ST LUCI 0704-0442-02 FIN PP 17488 ART STOVER PLUMBING INC 0704-0442-03 FIN ME 8288 COMFORT CONTROL OF ST 1 0704-0442-04 FIN RP 19085 ROOF CONCEPTS INC Owner / Builder Job Description INSPECTIONS - For Requests, Call: (772) 462-1261 Permit # Code Description Priori Date Sched. Res Description Inspector Date Insp. 0704-0442 115 Slab 0 10/17/2007 90 Approved Dave Johnson 10/17/2007 REAR PATIO SLAB ONLY 10/16/07 schedule for jean/ contr. bac 0704-0442 121 Termite Spray 0 10/17/2007 90 Approved 0704-0442 425 Sewer Connect 0 06/27/2007 90 Approved null Scheduled: Tue Jun 26 13:06:04 EDT 2007 with value: Wed Jun 27 00:00:00 EDT 2007 Resulted: Wed Jun 27 14:39:19 EDT 2007 0704-0442 104 Compaction Test 1 06/18/2007 90 Approved 0704-0442 105 Form Board Survey 1 06/26/2007 90 Approved 0704-0442 420 Plumbing Rough 1 06/27/2007 90 Approved null Scheduled: Tue Jun 26 13:05:03 EDT 2007 with value: Wed Jun 27 00:00:00 EDT 2007 Resulted: Wed Jun 27 14:39:37 EDT 2007 0704-0442 427 Temp.Toilet/Temp Culvert 1 90 Approved null Resulted: Wed Jun 27 14:38:59 EDT 2007 0704-0442 103 Eufer Ground 2 07/10/2007 90 Approved null Scheduled: Mon Jul 9 15:32:17 EDT 2007 with value: Tue Jul 10 00:00:00 EDT 2007 Resulted: Tue Jul 10 13:57:12 EDT 2007 Dave Johnson 10/17/2007 Greg Smyth 06/27/2007 Frank Williams 06/18/2007 Lydia Galbraith 06/26/2007 Greg Smyth 06/27/2007 Greg Smyth 06/27/2007 Dave Johnson 07/10/2007 Permit Nurl 10704-0442 0704-0442 115 Slab 2 07/10/2007 90 Approved Dave Johnson 07/10/2007 null Scheduled: Mon Jul 9 15:32:49 EDT 2007 with value: Tue Jul 10 00:00:00 EDT 2007 Resulted: Tue Jul 10 13:57:38 EDT 2007 ' 0704-0442 121 Termite Spray 2 07/10/2007 90 Approved Dave Johnson 07/10/2007 null Scheduled: Mon Jul 9 15:33:28 EDT 2007 with value: Tue Jul 10 00:00:00 EDT 2007 Resulted: Tue Jul 10 13:57:59 EDT 2007 0704-0442 118 Column 3 07/20/2007 81 Disapproved Dave Johnson 07/20/2007 null Scheduled: Thu Jul 19 15:30:27 EDT 2007 with value: Fri Jul 20 00:00:00 EDT 2007 Resulted: Fri Jul 20 14:15:29 EDT 2007 0704-0442 118 Column 3 07/24/2007 90 Approved Dave Johnson 07/24/2007 Re -inspection 1 Scheduled: Mon Jul 23 15:27:13 EDT 2007 with value: Tue Jul 24 00:00:00 EDT 2007 Resulted: Tue Jul 24 14:11:06 EDT 2007 0704-0442 125 Tie Beam 3 07/24/2007 90 Approved Dave Johnson 07/24/2007 Re -inspection 1 Scheduled: Mon Jul 23 15:27:50 EDT 2007 with value: Tue Jul 24 00:00:00 EDT 2007 Resulted: Tue Jul 24 14:10:42 EDT 2007 0704-0442 125 Tie Beam 3 07/20/2007 81 Disapproved Dave Johnson 07/20/2007 null STEEL NOT TIED. EPDXY STEEL TO FOOTER ON BACK PORCH. ADDRESS STEEL INFOOTER ON PORCH Scheduled: Thu Jul 19 15:29:55 EDT 2007 with value: Fri Jul 20 00:00:00 EDT 2007 Resulted: Fri Jul 20 14:15:12 EDT 2007 0704-0442 133 Window/Door Bucks 4 08/07/2007 90 Approved Dave Johnson 08/07/2007 null Scheduled: Mon Aug 6 07:52:21 EDT 2007 with value: Tue Aug 7 00:00:00 EDT 2007 Resulted: Tue Aug 7 14:22:05 EDT 2007 0704-0442 134 Roof Sheathing 4 08/02/2007 90 Approved Dave Johnson 08/02/2007 null Scheduled: Wed Aug 1 15:25:48 EDT 2007 with value: Thu Aug 2 00:00:00 EDT 2007 Resulted: Thu Aug 2 11:26:00 EDT 2007 0704-0442 137 Strapping 4 08/02/2007 81 Disapproved Dave Johnson 08/02/2007 null need stap installed at end of jack truss (front porch) on beam Scheduled: Wed Aug 1 15:26:18 EDT 2007 with value: Thu Aug 2 00:00:00 EDT 2007 Resulted: Thu Aug 2 11:25:14 EDT 2007 0704-0442, 137 Strapping 4 08/06/2007 90 Approved Dave Johnson 08/06/2007 Re -inspection 1 Scheduled: Fri Aug 3 15:53:28 EDT 2007 with value: Mon Aug 6 00:00:00 EDT 2007 Resulted: Mon Aug 6 14:40:20 EDT 2007 0704-0442 145 Truss Drwg 4 08/02/2007 90 Approved Dave Johnson 08/02/2007 null Scheduled: Wed Aug 1 15:26:54 EDT 2007 with value: Thu Aug 2 00:00:00 EDT 2007 Resulted: Thu Aug 2 11:25:38 EDT 2007 0704-0442 127 Mullion 5 08/23/2007 90 Approved Dave Johnson 08/23/2007 null Scheduled: Wed Aug 22 15:38:34 EDT 2007 with value: Thu Aug 23 00:00:00 EDT 2007 Resulted: Thu Aug 23 14:39:35 EDT 2007 0704-0442 136 Roof Dry-in/Tin Tab 5 08/10/2007 90 Approved Greg Smyth 08/10/2007 null Scheduled: Thu Aug 9 08:58:59 EDT 2007 with value: Fri Aug 10 00:00:00 EDT 2007 Resulted: Fri Aug 10 14:36:15 EDT 2007 0704-0442 140 Construction Rough Frami 5 08/27/2007 90 Approved Dave Johnson 08/27/2007 null Resulted: Mon Aug 27 14:27:23 EDT 2007 0704-0442 148 Window/Door Attachment 5 90 Approved Dave Johnson 08/27/2007 null Resulted: Mon Aug 27 14:28:45 EDT 2007 0704-0442 238 Electric Rough 5 08/27/2007 90 Approved Dave Johnson 08/27/2007 null Resulted: Mon Aug 27 14:27:42 EDT 2007 0704-0442 351 Mechanical Rough-In(ducl 5 08/27/2007 90 Approved Dave Johnson 08/27/2007 Re -inspection 1 Resulted: Mon Aug 27 14:28:01 EDT 2007 0704-0442 423 Plumbing Top Out 5 08/27/2007 90 Approved Dave Johnson 08/27/2007 Permit Nun 0704-0442 null Resulted: Mon Aug 27 14:28:25 EDT 2001 0704-0442 650 Frame -all 5 08/27/2007 i 74 Cancelled by Building I Barbara Counsello 08/27/2007 null Scheduled: Fri Aug 24 10:28:14 EDT 2007 with value: Mon Aug 27 00:00:00 EDT 2007 0704-0442 135 Wall Sheathing 6 09/05/2007 93 Not Required Dave Johnson 09/05/2007 9/4/07 INSPECTOR PLEASE CHECK TO SEE IF THIS INSPECTION IS REQUIRED. bac Resulted: Wed Sep 5 15:00:24 EDT 2007 THIS IS A BLOCK HOME WITH NO WALL SHEATHING 0704-0442 141 Insulation 6 09/05/2007 90 Approved Dave Johnson 09/05/2007 HVAC Calcs spec 8' ceiling height * Plans spec 10' ceiling ht * Inspector to verify in field for compliance w/ J calc * Jmc May Require Revision Scheduled: Tue Aug 28 13:46:51 EDT 2007 with value: null Scheduled: Tue Aug 28 13:47:11 EDT 2007 with value: null Scheduled: Tue Sep 4 13:54:46 EDT 2007 with value: null Resulted: Wed Sep 5 15:00:44 EDT 2007 0704-0442 167 Roof Final 6 09/05/2007 90 Approved Dave Johnson 09/05/2007 null Resulted: Wed Sep 5 15:01:06 EDT 2007 0704-0442 259 Power Release Form 6 92 Accepted As Noted Frank Williams 06/29/2007 0704-0442 900 Plan Revision 6 09/04/2007 92 Accepted As Noted Joe Cicio 09/04/2007 Per inspector 08/27/2007 Job ceiling_ s are @ 8.0' * Energys would be correct * Plan needs to be revised * [ revision complete 09/04/2007 Jmc] 0704-0442 153 Insulation Certification 7 92 Accepted As Noted Barbara Counsello 10/09/2007 0704-0442 260 30 Day for Testing 7 11/13/2007 90 Approved Dave Johnson 11/13/2007 null Scheduled: Fri Nov 9 12:51:47 EST 2007 with value: Tue Nov 13 00:00:00 EST 2007 0704-0442 800 Address Final 7 11/13/2007 90 Approved Dave Johnson 11/13/2007 0704-0442 172 Hurricane Panels (shutter: 8 12/13/2007 90 Approved Dave Johnson 12113/2007 0704-0442 261 30 Day Expired 8 01/14/2008 92 Accepted As Noted Barbara Counsello 12/1.3/2007 0704-0442 804 Driveway Bldg 8 12/13/2007 90 Approved Dave Johnson 12/13/2007 0704-0442 808 Landscaping/Trees 8 12/13/2007 90 Approved Dave Johnson 12/13/2007 0704-0442 996 Final Termite Treatment 8 12/13/2007 90 Approved Dave Johnson 12/13/2007 0704-0442 999 Final Inspection 8 12/13/2007 99 Final Approval Dave Johnson 12/13/2007 null Scheduled: Wed Dec 12 16:55:57 EST 2007 with value: Thu Dec 13 00:00:00 EST 2007 Permit Nunj 10704-0442 RECEIVED :�-, s *M HiJ LETT Pre -Construction Termite 1-800-285-7378 Property Informatiioon Treatment Date ,� Time / ; 00 Lot Block ,5 wag Sub ivision Name Street Address (If known) �L City State Zip Owner Name (If known) OCT 18 2007 Public Works -St. Lucia County, I=L Treatment Builder/Contractor Name of Builder Shell Contractor Construction Type Monolithic Floating/Stemwall Patio 9 Entry Driveway Product/Treatment Inforyration Treatment Type: Underslab Patio/Driveway Final Other Wood Treatment Product: Disodium Octaborate (Boracare ) Probuild TC Cypen ethrin Other ---/ Car keyieArlet Concentration J NTixedProduct Applied ,D Square Feet Treated 'D`00 Linear Feet Treated ❑ If this box is checked, then Final Perimeter treatment has been completed and the following statement is applicable: Certificate of Compliance: This building has received a complete treatment for the prevention of subterrranean termites. This treatment is in accordance with the rules and laws established by the Florida Department of Agriculture and Consumer Services. Applicator's Name (please print) Applicator's Signature HES-TE019 Rev 05/06 ©Hulett Environmental Services 09/27/2007 07,43 FAX 772 498 6758 GALE INSULATION ••pity of Port Saint -Lucie Building.�•DepalrtmenL: Q z O _1JL w Q z 0 Sp IA 002/007 INSULATION CERT'IFICATIO "E] Permit* C)_16A ILG) OCT 0 ..0 2007 Insulation Contractor Name: GALE INSULATION Jobsite Contractor: to �Fn&• - (ruP ri - 1 Jobsite Address: Vm (-,), k� �;r✓ �x� c� �n �b X / .Section: Block:, Lot: Q ling Insula LW Manufactures Name: CERTAINTEED Insulation Type: FIBERGLASS BATTY R-Value of Insulation. 19 Thickness of Insulation Installed: 6.25 INCISES Location of Insulation Installed: _ A/C CEILING ,AREA Date of Installation: R ( ! Wall lusulation Manufactures Name: � FI-FOIL CORP Insulation Type: REFLECTIVE FOIL R-Value of Insulation: 4.1 Thickness of Insulation Insixilled: 3r 4 INCII -- Location of Insulation Installed: CBS EXTERIOR WALLS Date of Installation: •„� l�l ,_,r Please Check One: Q Attic insulation instaalled with ventilation"per R808.1, R806.2 and R806.3 Florida Residential Code 2004 ❑ Conditioned attic assembly insulation has been installed per R-808.4, Florida Residential Code 2004 THIS CAM MUST BE POSTED IN A PROMINENT LOCATION AND RETURNED TO THEPOVING qEPJMTMENT BEFORE YOUR, FINAL INSPE"OK. O4w,-- PSL07-9389 Insulation Cantraators Signature PSL License 9 09/27/2007 07:43 FAX 772 409 0-7!59 GALE INSULATION 1@003I007 Cost uedon under this permit will be dome in accordance with the new FBC/FRC 2004 CITY OF FORT ST. LUCIE SUB40NIRWOR PIWit TYPE OF PERMIT. (KW. i' Ec AG. � �45 901AR PERMIT ; MASTER PERMIT # ('),-1b(i - 0-AIA-Q n,o�nr DIM IPAW �.�a� C&p. GALE INSULATION 3601-A Crossroads Pkwy Ft.Plerge,34945 9389 ooNrw►cro+r,�a+�urr �+ (772) - 7 2) 489-6250 use a s�aaw Residential MWOMOM @pair �"°°eron ❑u'A""°" ❑oeae ooemwom 311cm FONomoes: vAU)NIN ,, FW. THIS PERMIT uLCOMES NULL AND VOID IF CONSTRUCTION OR WORK AUTHOMZW IS NOT COMMENCED WINN 6 MONTHS, OR IF 0ONMWCt10N OR WORK 5 SUSPENDED OR A$ANDONED FOR A PERIOD OF 6 MONTHS AT ANY TIME AFM WORK IS COMMENCED. OV1 M AMIR. Ghat a1 me flxpobp MdA1XIpAa, k aoa�ete «,d,hot arwauv� oe db� ti �anpYs,oa wAh d appAcobte RM gp*wQ ca,wx* n and=ft w,w WroOM, Mmmm1oRECMANOTICEOFoomENc1; WWYMuNYM IMFORtgRamm 10 YOM PROW.. F1, 71 &1351i1 IF YOU �SIF►�q 1p QRDW FiN�WCN®, i`WtM YIOUR lg� OR AN ATIpRt�Y 9C�flRE AECORI>r'a� Y� t�O�RCE OF OOMf�ENC!` 30 a 0mlacbr Pam na��O a c r Owr& e. l l l Lindsay Hudson Commission 9 DD593519 Expires OC%ber 7.2010 �1�gFi.•�nKma,Ma IOOee!!tOfB IVGqur eG iD b Qvggr aApe[+: MIT VAMM oiv CWL M.a MIM PAoN nos ohv of n _, CA9H !0 AAMW 0- _ REM * CH= f C, 14ECEIVED JUL 10 2007 4 Public Works I K. St. Lucie County, FL �ULETT Y/ cavisoa�castw� ,/' Pre -Construction Termite Treatment 1-800-285-7378 01 CDq _0L Property Information Builder/Contractor Treatment Date _ Time Name of BY1ljej'4Wt&";P Lot Block Subdivision Name Shell Contractor :Ka' Co truction Type Street Address (If known) Monolithic Floating/Stemwall City State Zip Patio Entry Driveway Owner Name (If known) Producreatment Information Treatment Type: Underslab Patio/Driveway Final Other Wood Treatment Product: Disodium Octaborate (Boracare) P Other Concentration Mixed Product Applied / Square Feet Treated _i Linear Feet Treated (/ ❑ If this box is checked, then Final Perimeter treatment has been completed and the following statement is applicable: Certificate of Compliance: This building has received a complete treatment for the prevention of subterrranean termites. This treatment is in accordance with the rules and laws established by the Florida Department of Agriculture and Consumer Services. ►��s'r- Applicator's Name (please print) Applicat gnature HES-TE019 Rev 05/06 ©Hulett Environmental Services VIE&TI)UNK'U"LBIERGER ENGINEERI N ; & TESTING, INC. \ -S, Project Name: Spanish Lakes .,., /�, '1 Report Date: 05-09-07 C�� Port St. Lucie, Florida 0 �C Address: 76 Mediterranean East Client Name: WYNNE Building Corporation Project No.: 05-10-2005 8000 U.S. 1, Suite 402 Date Tested: 05 08 07 Port St. Lucie, Florida 34953 Technician Initials: NOP Attn: Ms. Janet Toombs Progress Report No.: 14 (Sheet 1 of 1) Test No. Probe Depth (in) F;. Maximum Dry Density (cf) Optimum Moisture (%) Dry Density (cf) Cone Resistance' (tsf) Moisture %) Minimum Required Compaction (%) Percent Maximum Density Test Result 1 12 107.5 13.0 104.1 - - - 10.3 95 96.8 Pass 2 12 107.5 13.0 104.7 - - - 11.0 95 97.4 Pass 3 12 107.5 13.0 103.7 - - - 9.6 95 96.5 Pass Type of Held Density lest: O AJ 1 M L 1 Sao kA) AJ 11V1 U Zy.4c t) t1J 11V1 1J L7J / Minimum Required Compaction Based on: (X) AASHTO T-180 (ASTM D 1557) Q AASHTO T-99 (ASTM D 698) 1 --.:--.—A F..— . e . ..et-....om-- A;. .l.ra:..Pa . 41, a Rra:narri-Kilman MnrlPl Q-71d hand-lip1d rnne nenetrnmeter Test` No iSollE H T e .. 4k .Elevation = N h n " fiest.Isoca 6n 76,'1Vledife "rail6an:East=p , A ti" r,. 1 1 0-12 At front of lot 2 1 0-12 At center of lot 3 1 0-12 At back of lot 7 0V — 0 9 L Elevation Referenced to: NV 1 ,at,SQIt T .,ems . ate.. Ate. ? 3'-•,-ns .�°- 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backrdl - Water 6 Utility Backfill - Storm 7 Roadway Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: Note: The original of this report was signed and sealed by ND O AISL (X) Utlier lncnes oeiow top or imai graae. cc: Client...(1) "B" (772-201-8443) will pick up ... (2) 'Crai'e E. Dunkelbere v FL �o�� 3 a registered engineer in accordance with Rule 61G15-18.011 of the Florida Adn6istrativ C� This report is submitted as the confidential property of our client and authorization for publication of statements, conclusdons or extracts from this report is reserved pending our written approval. The above -referenced testing was performed at the locations and depth interval describe the associated report date. No other warranties with regard to subsurface exploration, recommendations or design are expressed by this firm. on Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://Stiucieco.gov/ce BUILDING PERMIT Issued: 06/15/2007 Conf #: 730 Permit #: SLC- 0704-0442 Job Location: 76 E MEDITERRANEAN BLVD City: PORT ST LUCIE Permit Type: Building Residential (SFR) Job Description: CONSTRUCTION OF SINGLE FAMILY RESIDENCE - LAUREL MODEL LEFT Subdiv: St Lucie Gardens S/D Lot: Block: Parcel: 3414-501-1701-000/9 Page 1 Contractor WYNNE MATTHEW L WYNNE DEVELOPMENT CORP (772) 878-5513 8000 S US 1 PORT ST LUCIE, FL 34952 Property Owner WYNNE BUILDING CORP (772) 878-5513 12804 SW 122ND AVE MIAMI, FL 33186 Setbacks Left: 7.00 Right: 9.00 Front:35.00 Rear: 19.00 Zoning: RMH-5 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 1,904.00 Minimum Floor Elevation: Flood Map: 283F Flood Zone: X Elev: Job Value: $ 0.00 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(l0), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange �?07 Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 24 April 2007 Job Address: 76 E MEDITERRANEAN BLVD Received By: goycochb Paid With: CK Paid By: WYNNE DEVELOPMENT Building Receipt Sign: Receipt #: 0000053414 'ermit Number: SLC- 0704-0442 Amount: $250.00 �redit Card Number: Check Number: 028274 5-1 LUUM kouUiV!1" ruxudIt— vvviciILZ BUILDING & ZONE : G DEPARTMENT BUILDING PERNIIT SUB -CONTRACTOR SUAUKARY WYNNE DEVELOPMENT CORPORATION will be using the (campanyrUWkWLW name) 76 Mediterranean East following sub -contractors for the project located at -q= A n i � � _T � l o T (Wset address or property fax ID d) . It is understood that if there is any change of status regarding the participation of any o the sub -contractors .listed below, 1 will immediately advise the Building and Zoning Department of St. Lucie County. Trade Name of Company/Contractor St. Lucie County/ State of Florida License Number r 17488 Plumbing Art Stover Plumbing Inc. ,. FC056644_ EbcUicai Joe's Electric of St. Lucie 04267 Co., Inc. RR0009122 8288 I;VAC/MarhaMcal 1 Comfort Control of SLC.., Inc- CACO24379 19085 Roofing Roof Concepts, Inc. CCC058241 Gas Hurricane Protection '•Alufab, Inc. ItBC052127 OWN 3FFICE USE ONLY: SLCCDV FORM NO.: 0034N PERMIT NUMBER: I ISSUE DATE: ST. LUCIE COUNTY PUBtki : WORKS BUILDING & ZONING DEPARTMENT BUILDING PERNU .. SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number. State of Florida Certification Number Of applicable): 17488 CFC05664 Art S-tover Plumbing Inc.-__, has agreed to be (companylndividual name) the Plumbin-a-- -- sub-contractorfor Wynne Development Corporation (type of construction trade) (name of the prime contractor) .76 Mediterranean East for the project located at Spanish Lakes I It is understood that, (street address or property tax ID Aq if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO.004-00). BUSINES kAIEER (original signatures required): ArthUr Sri_ 04/20/07 signature Print name Date business name: Art Stampr P1 iimhi n0 Tnm address: 554 NW Mercantile Placer;: city,state,zip: port St, Lucie, FL 34986 phone: 772-.e. 7 8-6929 CE€USE_fONL•'Y: PERMrT#r I I ISSUE DATE SLCCDV FORM NO.: 002-00 ST. LUCIE COUNTY PUBZ,IC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number. State of Florida Certification Number (If applicable): 04267 , ER0009122 Joe's Electric- _ has agreed to be (companylndividual name) the electrical _..._ (type of construction trade) sub -contractor for Wynne Development Corporation (name of the prime contractor) -76 Mediterranean East for the project located at Spanish Lakes I It is understood that, (street address or property tax ID #) if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO. 004-00). BUSINESS QUALIFIER (original signatures required): �• Joseph Herndon.... t si ature Print name 04/20/07 Date business name: t Joe's Electrio of St.Lucie- Ido. Inc address: 951 Wag-ne.r...Place city,state,zip: Fort Pierce FL 349.82 phone: ...772-465-2363 OFF..ICEUSEjONLY.- SLCCDV FORM NO.: 002-00 PERMIT# I I ISSUE DATE ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number. State of Florida Certification Number (if applicable): CACO24379 Comfort Control of 3Lc,, Inc. has agreed to be (company/individual name) the air co,ndi-t on-ing sub-contractorfor Wynne Development Corporation (type of construction trade) (name of the prime contractor) for the project located at 76;Mediterranean East p) S n i g h r.a ka c T It is understood that, (street address or property tax ID #) if there is any change of status regarding our participation with the above mentioned G •+ project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO. 004-00), BUSINESS QUALIFIER (original signatures required): Barry ZimmerrnAn-r 04 20 07 a u Print name Date business name: Fnrt Cnn t rn l o f address: 7.501 Ri-1 i-mnrA nr. _ c4,State,zip: I Port St a Lucie , � L 34283 phone: 772--.785_-9.010 -- OFFIC67WSE'40NLY: SLCCDV FORM NO.: 002-00 -1 ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERNM S.UB-CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number. State of Florida Certification Number of applicable): 19085, CC-0058241 Roof Concepts, Inc.- has agreed to be (wmpanyAndividual name) the roofing. - - . - Sub-Contractorfor wYnfte Development Corporation (type of construction trade) (name of the prime coritraotor) •76 Mediterranean East for the project located at Spanish Lakes I It is understood that, (Street addmw or property tax ID s) if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV FORM NO.004-00). BUSINESS QUALIFIER (original signatures required): i%'1�1+ 0C • /-ri2/ Anthony,L. 04/20/07 sign re Print name Date business name: Ro_nf C_nnaPpts. Tnn- address: 2121 G C'nn.an+ , z►vr� _ city,state,zip: Port St. Luci.eg FL 34953 phone:' -.772-344-3717 SLCCDV FORM NO.: 002-00 PERMIT* 1 I ISSUE DATE f FR@Pl.:ALUFAB HURRICANE SHUTTERS 1 FAX NO. :3056888033 -mar. 20 2007 11:28AM P2 BUILDING & ZOMNGDEPARTMNT ]BUMMO PUMT R1AGRZT&MNT St, 7AUcie' County Contractor Certification Nunobcr: 'State of Florida Cw6flcation Member (lrMVJjc b%): _ C C 0 5 .12 7 A 114 f.,a b , T nn r. ti i� have agreed to be the (CwWany Na=/ ndividuAi Name) h�rx i (za rwe shuxIg!rs -sub-contractor for Wy_rJ b _Vulopmant; Corp. ('ijrpe of Tradc) (Primary Contactor) 76 Mediterranean East f'otr the project located at S n a n i a }i T,a k ' T (Project S tct Addrea9 or Property Tax10 #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the B*Iding and Zoning Departmcni of St. Lucie County by personally filing a Change of Contractor notice. (Form: - sLCCDv No. 004-00) ]RUSIM SS QUALIFIER (Name of the Individual shown on the Contractoes License) ORTGINAI.1 SIGIYA,'x RES Alm UJRt`gu ��G«ilil�C Y _ Richard D. Andrade 4/20/07 S1©NATtJR13 �^ rFJN 1' NAME DATE Dusinesi Name: A 7 �i f�.� T n r• Address: 23000 NW 36 Ave. City/State/Lip: jvj j � -- - , F); 3,1054 ' Prone: 305-666-4701 email: Wynne Development Corp. 8000 South US1, Suite 402 Port St. Lucie, FL 34052 To: Lydia St, Lucie County Zoning Department Fax #: 462-2522 From: Ann Carabia Date: 05/07/2007 Pages: 1 (including cover) Office: 772-878-5513 Ext. 115 Fax: 772-878-7656 The proposed finished floor elevations for the following permits: 0704-0440 8 Rio Verde Way Above Road 21" 0704-0441 12 Palo Alto Above Road 22" Easfi_ _ _ _Above Load=_-20' Q704-0'2 __76_Mediter._r._ane_an_ �JL�E CMG ST. LUCIE COUNTY BUILDING & ZONING F�OR1�P 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 561-462-1553 FILLED LANDS AFFIDAVIT I, the undersigned, am the owner of the following described property: 76 Mediterranean East Spanish Lakes. I Part of 3414-501-1701-000/9 (Tax ID/Legal description/Address) for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number , I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this pro erty, St. Lucie County -is neither obliged nor liable to provide for, or maintain in any orm, adequate drainage off my property which will not adversely affect the immediate glommunity. Matthew Lyle Wynne 0- �,.*- 04/20/07 Property Owner Name Property Owner Signature Date STATE OF FLORIDA, COUNTY OF St. Lucie ACKNOWLEDGED BEFORE ME THIS 2 0 t h DAY OF A 2007, BY Matthew Lyle Wynne WHO IS PERSONALLY KNOWN TO ME'-M WHO HAS PRODUCED AS IDENTIFICATION. _ SIGNATURE OF NOT TYPE OR PRINT NAME OF NOTARY (SEAL) NOTARY PUBLIC TITLE COMMISSION NUMBER SUSAN MAGEE MY COMMISSION # DD 630093 EXPIRES: February 23, 2011 d; Bonded Thru Notary Public Underwriters Property Appraiser - St.Lucie Cow'FL 1, Page 1 of 1 PROPERTY RECORD CARD Wynne Building Corp Record: 1 of 6 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification It Site Address: 7950 S US HWY 1 ParcellD: 3414-501-1701-000-9 ��� •=ar�Gy Sec/Town/Range: 26 :36S :40E Account #: 41242 y Map ID: 34/26N Land Use: HTLS MTLS Zoning: CG City/Cnty: ST. LUCIE COUNTY '•��3, Ownership and Mailing Legal Description Owner: Wynne Building Corp ST LUCIE GARDENS 26 36 40 BLKS 1AND 2 LYG ELY OF US #1 Address: 12804 SW 122nd Ave R/W-LESS RDRS/W- (MAP 34/26N) (277.43 AC) Miami FL 33186-6203 Sales Information Assessment Final Total Land and Building Date Price Code Deed Book/Page 2006 Val: 41222800 Land Value: 36385500 Acres: 11.84 1/1/1900 0 / Assessed: 41222800 Building Value: 4837300 Ag.Credit: 0 Finished Area: 74525 SgFt Exempt: 0 Taxable: 41222800 TotalTax: 825288.71 BUILDING INFORMATION rs 1 rs 1""^"Ntaw' r' nas.[I•sw) �3 ) Image BM IS (]a0) IK 1 [M/) Op•I50.(••IB)) tla •a1e,(r. i31p7 U01.1B3,(I•BS) .N ..LL (3r6J 9'UR ii OM n IBID) CW • •(Iro) A (1 IS IM 1[ 31 OR B/S m) ••.BA9 (a3 1Bm)Available GI] (113) ' Exterior Features View: - RoofCover: - RoofStruct: - ExtType: MHPK - MH Parks YearBlt: 1987 Frame: - Grade: C - C EffYrBlt: 1987 PrimeWall: - StoryHght: 0010 - 1 Story No.Units: SecWall: - Interior Features BedRooms: 1387 Electric: - PrmintWall: -. FullBath: 0 HeatType: - AvgHt/Fl: 1/2Bath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth 1 3900-HTLS MTLS XCS.-Sq Feet 347500 2 3900-HTLS MTLS 130 -Site 1387 3 3900-HTLS MTLS XCS -Sq Feet 168035 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/prc.asp?prclid=341450117010009 4/24/2007 I Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucieco.gov/ce Date: 24 April 2007 Job Address: 76 E MEDITERRANEAN BLVD Received By: goycochb Paid With: CK Paid By: WYNNE DEVELOPMENT Sign: Receipt#: 0000053414 'ermit Number: SLC- 0704-0442 Amount: $250.00 "redit Card Number: Check Number: 028274 FILE u6-PY ,/ film SA-4 i ,J i S�\ 1, A lee- 3 2M.L . I ii = 2„ Q COPY 34'-0' .. 1 EGRESS 12-a• PORCH ( OPTIONAL) ' f TO POUR AFTER STUCCO WIRE LATH INSTUCCO ,� O MASTER ��'G�m I r BEDROOM ' , t G. O I T MT I ? • i i 1 � H i [Red 1 ItV-4' e ' O �Ia I GREAT � 0 CL SE I� ROOM i wuumeX m I oc I a Rod Shtlf '�9. n IL - r F g•-0• \ OT \ 442' HIGH WALL i i DINING KITCHEN 1-1/2' OVERHANG ROOM lo•-c• II�_1O. XO�X-VOT6 3 -0' — THES5 PLANS AND ALL PROPOSED WORK Wire Lathlge IL_�, / Stucoo Ce N E SpSJECT TO ANY CORRECTIONS j I I I H.B. REQUIRED BY FIELD INSPECTORS THAT L L"MAY It NECESSARY IN ORDER TO 'rn EGRESS _ , Y WITH APPMARLE CODES, -O• 4 -q• 15'-10' g•-B• 9'-c' i 34•-O' i AREA CALCULATIONS Living A/C = 1335 sq. ft. Entry = 55 sq. ft. Back Porch Total = 200 sq. ft. _ Garage = 31-4 sq. ft. Total Under Roof= 1904 sq. ft. S , LUCIE COON B �11LDINQ DI REVI D FOR CO PL CE {REVIEWED BY DATF_ LAN,D PERMIT h9U51' KEPT ON JOB OR NO INSR CTION WILL BE MADE S , LUCIE COON B �11LDINQ DI REVI D FOR CO PL CE {REVIEWED BY DATF_ LAN,D PERMIT h9U51' KEPT ON JOB OR NO INSR CTION WILL BE MADE Ll U T �ILE COPY 0 FORM 60OA-2004R � EnergyGauge® 4.5 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: WYNNE SPANISH LAKES LAUREL Builder: WYNNE Address: 76 Mediterranean East Permitting Office: City, State: PSL , FL Permit Number: 0704-0442 Owner: Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 2. Single family or multi -family Single family 3. Number of units, if multi -family I _ 4. Number of Bedrooms 2 _ 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft) 1335 ftz _ 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a.(Sngle, U=1.3) 41.0 ftZ b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 131.0 ftZ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 0.0(p) ft b. N/A c. N/A _ 9. Wall types _ a. Concrete, Ext Insul, Exterior R=4.1, 1056.0 ft- b. Frame, Wood, Exterior R=11.0, 115.0 ftz _ c. N/A d. N/A _ e. N/A _ 10. Ceiling types _ _ a. Under Attic R=19.0,1335.0 ftz b. N/A c. N/A _ 11. Ducts _ a. Sup: Unc. Ret: Unc. AH: Garage Sup. R=6.0, 76.0 ft b. N/A 12. Cooling systems a. Central Unit/Split Cap: 28.2 kBtu/hr _ b. N/A SEER:13.00 = c. N/A 13. Heating systems a. Electric Heat Pump/Split Cap: 26.0 kBtu/hr lkwj HSPF:7.70 b. N/A c. N/A 14. Hot water systems a. Electric Resistance Cap: 40.0 gallons = ULIM EF: 0.95 b. N/A c. Conservation credits _ (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.10 Total as -built points: 17485 PASS Total base points: 17621 I hereby certify that the plans and specifications covered by this calculation are in comoance with the Florida Energy Code. PREPARED BY: DATE:�i 1�1� I hereby certify that this bu 'n �51 de ' ed, is in' with the Florida Energy C d OWNER/AGENT: DATE: _ _ , Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: BATE: 1 Predominant glass type. For actu type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge@ (Version: FLRCSB v4.5) JZBE ST.gl�O� 1�COD WE FORM 60OA-2004R EnergyGauge® 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT, GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1335.0 24.35 5851.0 1.Single,U=1.27,Clear NW 1.0 6.0 20.0 40.71 0.97 790.0 2.Single,U=1.27,Clear SW 1.0 6.0 40.0 56.97 0.96 2193.0 3.Single,U=1.27,Clear SE 11.0 7.8 41.0 61.05 . 0.46 1154.0 4.Single,U=1.27,Clear SE 1.0 6.0 30.0 61.05 0.96 1764.0 As -Built Total: 131.0 5901.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Ext Insul, Exterior 4.1 1056.0 0.48 506.9 Exterior 1171.0 1.90 2224.9 2. Frame, Wood, Exterior 11.0 115.0 1.90 218.5 Base Total: 1171.0 2224.9 As -Built Total: 1171.0 725.4 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 21.0 4.80 100.8 Exterior 38.0 4.80 182.4 2.Exterior Wood 17.0 7.20 122.4 Base Total: 38.0 182.4 As -Built Total: 38.0 223.2 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1335.0 2.13 2843.6 1. Under Attic 19.0 1335.0 2.82 X 1.00 3764.7 Base Total: 1335.0 2843.6 As -Built Total: 1335.0 3764.7 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 167.5(p) -31.8 0.0 1. Slab -On -Grade Edge Insulation 0.0 167.5(p -31.90 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 0.0 INFILTRATION Area X BSPM = Points Area X SPM = Points 1335.0 14.31 19103.8 1335.0 14.31 19103.8 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT Summer Base Points: 30205.7 Summer As -Built Points: 29718.1 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 26200btuh ,SEER/EFF(l3.0) Ducts: Unc(S),Unc(R),Gar(AH),R6.0(INS) 30205.7 0.3250 9816.9 29718 1.00 29718.1 1.00 (1.09 x 1.150 x 1.00) 0.260 1.250 0.260 1.000 1.000 9658.8 9658.8 EnergyGaugeTM' DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 FORM 60OA-2004R - EnergyGauge® 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1335.0 9.11 2189.0 1.Single,U=1.27,Clear NW 1.0 6.0 20.0 14.71 1.00 293.0 2.Single,U=1.27,Clear SW 1.0 -6.0 40.0 11.35 1.01 458.0 3.Single,U=1.27,Clear SE 11.0 7.8 41.0 10.35 1.67 709.0 4.Single,U=1.27,Clear SE 1.0 6.0 30.0 10.35 1.02 317.0 As -Built Total: 131.0 1777.0 WALL TYPES Area X BWPM = Points Type 12. R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Ext Insul, Exterior 4.1 1056.0 2.36 2492.2 Exterior 1171.0 2.00 2342.0 Frame, Wood, Exterior 11.0 115.0 2.00 230.0 Base Total: 1171.0 2342.0 As -Built Total: 1171.0 2722.2 DOOR TYPES Area X BWPM = Points1 Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 21.0 5.10 107.1 Exterior 38.0 5.10 193.8 2.Exterior Wood 17.0 7.60 129.2 Base Total: 38.0 193.8 As -Built Total: 38.0 236.3 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1335.0 0.64 854.4 1. Under Attic 19.0 1335.0 0.87 X 1.00 1161.4 Base Total: 1336.0 854.4 As -Built Total: 1335.0 1161.4 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 167.5(p) -1.9 0.0 1. Slab -On -Grade Edge Insulation 0.0 167.5(p 2.50 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 0.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1335.0 -0.28 -373.8 1335.0 -0.28 -373.8 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: BASE AS -BUILT Winter Base Points: 5205.4 Winter As -Built Points: 5523.1 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 26000 btuh ,EFF(7.7) Ducts: Unc(S), Unc(R),Gar(AH), R6.0 5523.1 1.000 (1.078 x 1.160 x 1.00) 0.443 1.000 3061.3 5205.4 0.5540 2883.8 5523.1 1.00 1.250 0.443 1.000 3061.3 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge@ 4.5 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS:,, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2460.00 4920.0 40.0 0.95 2 1.00 2382.32 1.00 4764.6 As -Built Total: 4764.6 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 9817 2884 .4920 17621 9659 3061 4765 17485 PASS ,ZliE ST,g?�O ici ••'' � a 1,�,COD wE'��yS EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge@ 4.5 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter. penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1 /2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses I 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 allons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Se crate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FI*E CO ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 85.7 The higher the score, the more efficient the home. 1. New construction or existing New 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 4. Number of Bedrooms 2 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 1335 ft2 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a.(Sngle, U=1.3) 41.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 131.0 ft2 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 0.0(p) ft b. N/A c. N/A 9. Wall types a. Concrete, Ext Insul, Exterior R=4.1, 1056.0 ft2 b. Frame, Wood, Exterior R=11.0, 115.0 ft2 c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic R=19.0, 1335.0 ft2 b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH: Garage Sup. R=6.0, 76.0 ft b. N/A I certify that this home has complied with the Construction through the abo0.i! in this home before final inspbased on installed Code com Builder Signature: ,,,FL, 12. Cooling systems a. Central Unit/Split b. N/A c. N/A 13. Heating systems a. Electric Heat Pump/Split b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A _ c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) "lorida Energy Efficiency Code For Building features which will be installed (or exceeded) a new EPL Display Card will be completed Date: Address of New Home: J(Q JLJi T� nl?¢City/FL Zip:_!��, Cap: 28.2 kBtu/hr SEER: 13.00 Cap: 26.0 kBtu/hr HSPF: 7.70 Cap: 40.0 gallons EF: 0.95 4TI;E ST.9T�o�.e 1�C0 *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarTudesignation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areassee Summer & Winter Glass out ut on ages 2&4. areas, (Version: F�UNN v4.5) wri9htsoft Project Summary Job: the vl�chaka Entire House Byte: PZ 0/07 COMFORT CONTROL OF SLC, INC. Project Information For: WYNNE CORP. SPANISH LAKES "LAUREL", FL Notes: 2007/13.0 Design Information FILE COPY Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 - OF Design TD 15 OF Daily range L Relative Humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 19641 Btuh Ducts 1917 Btuh Central vent (21 cfm) 658 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 22215 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ftz) 1335 1335 Volume (ft3) 10676 10676 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 80 41 Heating Equipment Summary Make Ruud Trade Zephyr 13PJA Series - ICECO Model 13PJA30 Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 7.7 HSPF 26000 Btuh @ 47°F 94OF 0 cfm 0.044 cfm/Btuh 0.00 in H2O Sensible Cooling Equipment Load Sizing Structure 19654 Btuh Ducts 2307 Btuh Central vent (21 cfm) 352 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 21198 Btuh Latent Cooling Equipment Load Sizing Structure 2109 Btuh Ducts 672 Btuh Central vent (21 cfm) 892 Btuh Equipment latent load 3673 Btuh Equipment total load 24870 Btuh Req. total capacity at 0.70 SHR 2.5 ton Cooling Equipment Summary Make Ruud Trade Zephyr 13PJA Series - ICECO Cond 13PJA30. Coil UBHK-21+RCHJ-36A1 Efficiency . 13 SEER Sensible cooling 19740 Btuh Latent cooling 8460 Btuh Total cooling 28200 Btuh Actual air flow 940 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio 0.86 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrigihtsoft Right -Suite Residential 6.0.95 RSR21055 2007-Jun 11 10:17:45 ACCt\ C:\My Documents\Wrightsoft HVAC\Office FilesWisc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 1 1 wrightSofta Load Short Form Job: Date: 5110107 �•W■ham• Entire House By: Pz COMFORT CONTROL OF SLC, INC. Project Information For: WYNNE CORP. SPANISH LAKES "LAUREL",- FL Design Information Htg Clg Infiltration Outside db (OF) 42 90 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TD (OF) 28 15 Fireplaces 0 Daily range - L Inside humidity (%) - 50 Moisture difference (gr/lb) - 61 HEATING EQUIPMENT Make Ruud Trade Zephyr 13PJA Series - ICECO Model 13PJA30 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 7.7 HSPF 26000 Btuh @ 47°F 25 OF 940 cfm 0.044 cfm/Btuh 0.00 in H2O COOLING EQUIPMENT Make Ruud Trade Zephyr 13PJA Series - ICECO Cond 13PJA30 Coil UBHK-21+RCHJ-36A1 Efficiency 13 SEER Sensible cooling 19740 Btuh Latent cooling 8460 Btuh Total cooling 28200 Btuh Actual air flow 940 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio 0.86 ROOM NAME Area (ftz) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) FOYER 78 1781 969 78 41 2ND BDRM 188 3238 4030 141 172 BATH 50 550 301 24 13 HALL TO BATH 17 25 45 1 2 DINING/GREAT RM 513 7533 5948 328 255 MASTER BDRM 224 4858 4955 212 212 MASTER CLOSET 63 95 171 4 7 MASTER SINK AREA 36 529 264 23 11 MASTER BATH 49 722 360 31 15 LAUNDRY 46 1381 1930 60 83 V1-rr- JCA1 7A OAG anon n� I Ann 1%1 I VI IVI`Y 1T VT%J Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right -Suite Residential 6.0.95 RSR21055 AC:CA C:WIy Documents\Wrightsoft HVAC\Office Files\Misc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M 2007-Jun-11 10:17:45 Page 1 Entire House 1335 21558 21961 940 940 Other equip loads 658 352 Equip. @ 0.95 RSM 21198 Latent cooling 3673 TOTAI S 4 9 g Printout certified by ACCA to meet all requirements of Manual J 8th Ed. vvnghtsoft Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 ACCA C:wly Documents\Wrightsoft HVAC\Office Files\Misc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 2 1V 1- wrightssoft- Right-J Worksheet Entire House COMFORT CONTROL OF SLC, INC. Job: Date: 5110107 By: pz 1 Room name Entire House FOYER 2 Exposed wall 167.5 ft 16.0 ft 3 Ceiling height 8.0 ft 8.0 ft heat/cool 2.0 ft 5 Room area 1334.5 ft? 78.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A - 0.116 n 3.25 3.09 1208 1056 3430 3258 44 23 75 71 IA-clomd 1.270 a 35.56 91.12 41 41 1458 1426 0 0 0 0 1A-clom 1.270 a 35.56 91.12 30 0 1057 2734 0 0 0 0 1Aclom 1.270 s 35.56 37.88 40 40 : 1422 1391 0 0 0 0 11 1Aclom 1.270 w 35.56 91.12 20, 0 711 1822 0 0 0 0 111.10 0.600 n 16.80 17.40 21 21 353 365 21 21 353 365 W 12B-0sw 0.097 n 2.91 2.58 132 115 335 297 84 84 244 217 T-D 11 DO 0.390 n 11.70 11.31 17 17 199 192 0 0 0 0 C 1613-19ad 0.049 - 1.37 2.57 1335 1335 1831 3433 78 78 107 201 F 22A-vph 1.358 - 38.02 0.00 308 168 6369 0 16 16 608 0 6 c) AED excursion 0 -51 Envelope loss/gain 17175 14918 1387 803 12 a) Infiltration 2466 675 236 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances @ 1200 3 3600 0 0 Subtotal (lines 6 to 13) 19641 19654 16231 867 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 19641 19654 1623 867 15 Duct loads 10% 12% 1917 2307 10% 12% 158 102 Total room load 21558 21961T 1781 969 Air required (cfm) 940 940 78 41 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. jMt50'ft Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 .4CCP. C:1My Documents%Wrightsoft HVAC\Office Files\Misc BuildeAWYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 1 i -+1+- wrightssoft- RighW Worksheet Entire House COMFORT CONTROL OF SLC, INC. Job: Date: 5110/07 By: pz 1 Room name 2ND BDRM BATH 2 Exposed wall 26.0 ft 5.5 ft 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 12.5 x 15:0 ft 5.5 x 9.0 ft 5 Room area 187.5 ft2 49.5 ftx Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ft? °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool- Gross N/P/S Heat Cool 6 51A- 0.116 'n-, :` 3:25 ; '3.09 ,r `.208 -',188 61T .: i580 , = 44 44. :143 1$6 AA-clomd 1270 e_ 35.56 91,12 0 0 0 0 1A-clom ' 1.270 e'. 35.56 91:12 . 0 0 - ;0 , 0 0 '0 0 0 1R c1om. 1.270 <s, '.w-- 35:56 ,3788 0 ;,20 0 0 : 0 . 0 , 0 ;' 0 0. 11 1Ac1om ' 1 270 35:56 91:12 0 711 o , ' 0 � 0 ;0 11J0 ',,0.600:.n.. .^: 16.80 _: `.17.40 '::' 0 0, -.. • ' _0:':. p ., Y.O. p . p _; : p. t—D 12B-Osw 0.097 n 2.91 2.58 0 0 0 0 0 0 0 0 11 DO 0.390 n 11.70 11.31 0 0 0 0 0 0 0 0 C 166-19ad * 0.049 - 1.37 :' 2;57 " 188 ::188: 257, ` 482 _' . 50 Sp :..., ..'68 12l F 22A-vph 1.358 - 38.02 0.00 42 26 989 0 2 6 209 0 _ : 4 ,. ,. _r., a TZ, , .....,.. 7 t 4- 6 c) AED excursion 617 -16 Envelope loss/gain 2568 3502 420 247 12 a) Infiltration 383 105 81 22 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 2951 3607 501 269 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2951 3607 501 269 15 Duct loads 10% 12% 288 423 10% 12% 49 32 Total room load 3238 4030 550 301 Air required (cfm) 1411 172 24 13 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsoft Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 C:WIy Documents\Wrightsoft HVAC\Office Files\Misc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 2 wrigtt! fl Right-1 Worksheet Entire House COMFORT CONTROL OF SLC, INC. Job: Date: 5110/07 By: pz 1 Room name HALL TO BATH DINING/GREAT RM 2 Exposed wall 0.0 it 45.0 ft 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 5.5 x 3.0 ft 25.0 x 20.5 ft 5 Room area 16.5 ft= 512.5 ft' Ty Construction U-value Or HTM Area (ft2) Load ( Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) or perimeter perimeett er (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V 1A C1omd 11 270 a 35 56 43:09 9111,12 0 0 0 0 0 360 279 41 906 1458 861 1426' 1A-clom"- 1 270 e' 35:56 91 12 0 0 0 0 0_ 0 ` 6, 0; 1A�1om -1 270 s 35 56 37 88 0 _ 0 , 0 0 nz 40 : 4b 1422 .1,391 11 1A-clom" 1270 w; 3556 91..72 0 0 0 0 ', ,.: '. ,. 0 p ' J O 0 yJ I--D 126-Osw 0.097 n 2.91 2.58 0 0 0 , 0 0 0 0 . 0 11 DO 0.390 n 11.70 11.31 0 0 0 0 0 0 0 0 C'r' 166-19adi0.049 -=., ,. 1:37 =2:57. <z17 °,._. ' 17 23 ..'-z. • .. 42 , ., 513 513 :"a 703 1318. F 22A-vph 1 358 - 38.02 0.00 0 0 0 0 127 45 1711 .. 0Ar - u , Y , a-Ji _: , . ... -, ,• 1 1.,f 6 c) AED excursion -2 -314 Envelope loss/gain 23 40 6201 4682 12 a) Infiltration 0 0 663 181 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 23 40 6863 5323 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23 40 6863 5323 15 Duct loads 10% 12% 2 5 10% 12% 670 625 Total roam load 25 45 7533 5948 Air required (cfm) 1 2 1 328 255 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr-s40M1t:soflt Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 /��A C:WIy Documents%Wrightsoft HVAC\Office FilesWlisc BuildeAWYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 3 wrightwft Right-J Worksheet Entire House COMFORT CONTROL OF SLC, INC. Job: Date: 5110107 By: pz 1 Room name MASTER BDRM MASTER CLOSET 2 Exposed wall 40.0 ft 0.0 ft 3 Ceiling height 8.0 ft heaUcool 8.0 ft heaUcool 4 Room nsions 14.0 x 16.0 ft 9.0 x 7.0 ft 5 Room area 224.0 ft2 63.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft;"F) (Btuh/ft � or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 51A 0116 ri . . 3.25 3'09 320 290 942 895 p 0 0 0 IA-c1omd 1270 <e- 35'56 9112 0 0 0' 0 0 t0 0 A 1Ac1om 1270 a "s- 35.56 91.12 30 0 .4067 2734 _ 0 -•0, 0 0 .1Aclom 1 270 35.56 37;:88 0 = 0 0. 0' 0 0 0 ;,. 0 11 1A-clom 127t) w 35:56 91.12 0 0 0 - 0 ' ;:0 0 0 ;0 11J0: ...- 0.600 •, n'r 16;80 _ 17:40 0 .. •_ 0 0. _ :<.' ,;:0 0 V�J 12B-Osw 0.097 n 2.91 2.58 0 0 0 0 0 0 0 0 11 DO 0.390 n 11.70 11.31 0 0 0 0 0 0 0 0 —D ' C. 166=,19ad 57, , . ,. ` 224 , ..: , ^224 .,, :_ 307 ,. s .. 57fi -; : ;. `:63 : ; 63 F 22A-vph 1358 - 38.02 0.00 100 40 1521 0 0 0 0 0 :._ w . ' _ .. ♦ ;. '. ,_ .. t _ ` , i�'i. S- Y.,,. •. .,. t. ,F,.tL .:,.< S Y � L ` 5, 77 .. ". :_. .. ,t. , i.S• i. •. '. is 4 :C < 6 c) AED excursion B9 -9 Envelope loss/gain 3837 4273 86 153 12 a) Infiltration 589 161 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances'@ 1200 0 0 0 0 Subtotal (lines 6 to 13) 4426 4434 86 153 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4426 4434 86 153 15 Duct loads 1 10% 12% 432 521 10% 12% 8 18 Total room load 4858 4955 95 171 Air required (cfm) 212 212 4 7 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. .4&wr�ghtsoft Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 14 C:WIy Documents%Wrightsoft HVAC\Office Files\Misc BuilderlWYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 4 - wrighisoRight-J Worksheet d.daft Entire House COMFORT CONTROL OF SLC, INC. Job: Date: 5/10107 By: pz 1 Room name MASTER SINK AREA MASTER BATH 2 Exposed wall 5.5 ft 7.5 It 3 Ceiling height 8.0 ft heat1cool 8.0 ft heat/cool 4 Room dimensions 5.5 x 6.5 ft 6.5 x 7.5 ft 5 Room area 35.8 ft: 48.8 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft) Load number (Btuh/ft'-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat Cool 6 -51A 0.116 _ n. - 3.25 3A9 44 " 44 143 136 66 ' 60 195 165 1A-clomd 1.270 a 35.56 91.12 0 '0_ 0 0 0 0 0 0 1A-clom 1.270 a 35.56 91.12 0 0 0 .0 0 0 0 0 1A-c1om 1.270 s 35.56 37:88 0 0 0 0 0 0. 0 0 11 IA-clom 1.270 w 35.56 91.12. 0 0 0 0 0 0 0 0 11J0_-. 0.600 . -n.. . 16.80 _,_17.40. _ __ .w;.0. _.. _ ___0 VN L—D 12B-0sw 0.097 n 2.91 2.58 0 0 0 0 0 0 0 0 11D0 0.390 n_ ,11.70 11.31. _ 0 0 0,__ 0___. 0_ 0 0 0 C _. 16B-19ad._ 0.049 -.. _ 1.37. .. -2.57_ 36, _ _36 _._ 49...___..._92:. 49.._.._. _ 49. __ _ F 22P`-vPh 1.358 - 38,02 . _ 0.00, 2 - 6 209 0 ._'... .. ... _ 4 _ ... _ 8 . ,._._67 285 _ _ _125 6 c) AED excursion -14 -19 Envelope losstgain 401 214 547 292 12 a) Infiltration 81 22 110 30 b) Room ventilation 0 0 0 0 13 Internal gains:. Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 482 236 657 322 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 482 236 657 322 15 Duct loads 110% 12% 47 28 10% 12% 64 38 Total room load 529 264 722 360 Air required (cfm) 23 11 31 15 Printout certified by ACCA to meet all requirements of Manual J 8th Ed'. Wrighltso•Ft Right -Suite Residential 6.0.95 RSR21055 2007-Jun-11 10:17:45 . Ct� C:\My Documents\Wrightsoft HVAC\Office FilesWlisc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M Page 5 wrightsoft Right-.1 Worksheet Job: Entire House Date: 5/10/07 COMFORT CONTROL OF SLC, INC. By: pz 1 Room name 2 Exposed wall AU LAUNDRY L KITCHEN 3 Ceiling height 13.5 ft 8.5 ft 4 Room dimensions 8.0 ft heaUcool 8.0 ft heat/cool 5 Room area HTM 6.5 x 7.0 ft 45.5 ft2 Area (ft-) Load 10.5 x 7.0 ft 73.5 ft' TY Construction U-value Or number (Btuh/ft2-°F) (Btuh/ftz) or perimeter (ft) (Btuh) Area (ftz) Load or perimeter (ft) (Btuh) Heat `.3.25 35;56 Cool '3.09 91.12 Gross N/P/S : _ 60 60 0 Heat Cool Gross ;, " 198 - 785 ,'' ; 66 N/P/S Heat Cool 6 51A 1A clomd 0.1.16 1 270 ...n ,-p 6B 221 =:21C 1A�1om 7A c1om.. 1270 1 270 •e °:'s 35i56 91:12 0 0 0 .. 0 0 ' " 0 :. 0 :, A 0 0 , 0 C 11 1A . 35.56 ", 37:88 0 0 O 0 Glom ; 11J0 1 270 ,w' ,85:56 91.Q2 0 0 0 0' 0 �0 0 C 126-0sw 0600 0.097 =:h n 16:80 2.91 17.40 2.58 0 ._ 0. 0: A.-' ,0 0 0.- A 0. 0 0 C 1 0.390 n 11.70 11.31 48 31 17 17 90 80 0 0 0 C C F B- 166-19ad 22A-vPh �0 04g _ :.1:37 <. .;2.57 ?'. 46 46 199 192 i 62 .192 z.74: 0 0 0 0 1358 38.02 0.00 11 14 513 p •' ..74 101 A 89 =. .. , , 6 c) AED excursion -102 Envelope loss/gain ' -158 645 241 1060 473 12 a) Infiltration b) Room ventilation 1990 p 125 34 0 0 13 Internal gains: Occupants @ 230 0 Appliances @ 1200 1 0 1200 0 2 0 2400 Subtotal (lines 6 to 13) 770 2675 1259 1727 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 10% 12% 1259 1727 770 2675 123 203 10% 120/c 75 314 Total room load Air required (cfm) 136811 1983 845 2989 37 128 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. NO&-1r1S3 7tSOirt Right -Suite Residential 6.0.95 RSR21055 AC� CWY Documents\Wrightsoft HVAC\Office Files\Misc Builder\WYNNE SPANISH LAKES LAUREL.rsr Calc = M 2007-Jun10:1Page ge 6 6 L 9 'd Ar ",7& 0 Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce PROPERTY INFORMATION Address: 76 MEDITERRANEAN BLVD E Unit # City / State / Zip: PSL Parcel #: 3414-501-1701-000/9 Zoning: RMH-5 APPLICATION INFORMATION Permit Number: 0704-0442 Activity Type: New Permit Type: Building Residential (SFR) CONTRACTOR INFORMATION Review Comments FL 34952 Jurisdiction: St. Lucie County Lot # : Block: Contractor Name: WYNNE MATTHEW L Business Name: WYNNE DEVELOPMENT CORP Business Addr: 8000 S US 1 City / State / Zip: PORT ST LUCIE, FL 34952 Page 1 Owner(s): WYNNE BUILDING CORP Application Type: Master Permit w/subs Other Activity: Stories: 1 Automatic Sprinkler System? ❑ Fax Number 772-878-7656 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Complete Date Released Documents Missing Pending 05/07/2007 1 Comment NEED TO BRING IN A RECORDED N.O.C. @ PERMIT PICKUP Front Counter Review Complete Beatriz Goycochea 04/24/2007 04/24/2007 Notified for Pickup Pending Plans Examiner Review Incomplete Joe Cicio 05/14/2007 05/14/2007 1 Comment BOTH ENERGY CALCS MUST BE DESIGNED TO THE CURRENT 4.5 vsn. AND BEAR THE ORIGINAL SIGNATURES OF THE PREPARER AND THE CONTRACTOR. THIS MUST INCLUDE THE E.P.L.CARDS * CONTRACTOR TO PROVIDE PROPER D ENTATION THAT THE SUMMER WINTER AS -BUILT ORIENTATIONS ARE CORRE I G CALCULATIONS MUST BE SITE -SPECIFIC TO THE STRUCTURE BEI G -R r v a - /3 . o7_ 05/14/2007 2 Comment ENGINEER TO SUPPLY A SIGN EA LETTER THAT THE MASTER PLAN O ILE COMPLIES WITH THE 2006 SUP N S OF THE 2004 F.B.C. 05/14/2007 3 Comment SOFFITS MUST BE DESIGNED PER R-703.1.1 FOR THE LOADS SPECIFIED IN R-301.2[2] 05/14/2007 4 Comment Code Compliance Division Review Comments 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 Page 2 http://stiucieco.gov/ce TRUSS PLANS MUST BE UP -DATED TO THE 2006 SUPPLEMENTS OF THE 2004 F.B.C. [see H-602.1.6.1 for plan requirements] SIGNED AND SEALED PER 61G-15 AND REVIEWED AND APPROVED BY E.O.R. 05/14/2007 5 Comment 13a5-ocs IS AN INCORRECT CONSTRUCTION NUMBER AS STATED IN THE MANUAL J CALCS FOR THE O.S.WALLS' IF USING FI-FOIL AS STATED, PLS REVISE THE NUMBER [ POSIBLE CUSTOM WALL] see fi-foil specs for designs 05/14/2007 6 Comment CONTRACTOR TO NOTE THE ORIENTATION OF THE HOME ON THE SURVEYS [plot plans] 05/14/2007 7 Comment COMMENTS MAILED TO CONTRACTOR AS OF THIS DATE Zoning Review Complete Lydia Galbraith 05/07/2007 05/07/2007 TRANSMISSION VERIFICATION REPORT TIME NAME FAX TEL SER.# 05/13/2007 22:01 ST LUCIE CO 7724625267 7724621735 BROL4J160710 DATE DIME 05113 22:00 FAX NO./NAME 98787656 DURATION 00:00:31 PAGE(S) 02 RESULT OK MODE STANDARD ECM St L Pj Co. FL Date Initved 5 eclflc Purpose Survey Location Of 1=ormboard For: WYNNE BUILDING CORP STREET ADDRESS 76 76 MEDITERRANEAN EAST (OCCUPIED) DESCRIPTION EwsTtNG MOBILE HOME _ Being all of 76 MEDITERRANEAN EAST, of the unrecorded plat of SPANISH LAKES PHASE I, of St. 0 10 20 Lucie County, Florida. 6=.1 �� I 0 o GRAPHIC SCALE IN FEET co EAST&, r-_1 110.00' m N LEGEND & ABBREVIATIONS 0.00' ASSUMED 0 p CONC. DENOTES CONCRETE P.B. DENOTES PLAT BOOK I ^ 35.00' 19.00, P.C.P. DENOTES PERMANENT CONTROL POINT C.M. DENOTES CONCRETE MONUMENT r DENOTES PLAT DATA DENOTES�REC C; DENOTES CALCULATED FROM FIELD MEASUREMENTS RR& C DENOTES RONCROD & IAL CAPS BOOK DENOTES PROPERTY W n 00 O LINE PG. DENOTES PAGE M) DENOTES MEASURED DATA COR. DENOTES CORNER Z O Li 0 ID DENOTES IDENTIFICATION NUMBER P.O.B. DENOTES POINT OF BEGINNING DEMOTES FLOW LINE P.O.C. DENOTES POINT OF COMMENCEMENT Q Z 7 G 9.85' ® t . TOB DENOTES TOP OF BANK I.P. DENOTES IRON PIPE TYP. DENOTES TYPICAL I.R. DENOTES IRON ROD LJ a 9' 0' L0 FND. DENOTES FOUND DENOTES UTILITY EASEMENT zl a 3 13 p EXISTING FORMBOARD •- ELEV=1.74' L.B. DENOTES LICENSED BUSINESS P.I. DENOTES POINT OF O.H.U. DENOTES OVERHEAD UTILITIES P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR _ M 6.00' Li (AVERAGE HEIGHT ABOVE ® DENOTES WATER METER DENOTES ELEVATION (TYPICAL) EDGE OF PAVEMENT) O o a� 1 �^ o 04 N GENERAL NOTES W �— Zi �_ 1s oo' Z 1. The bearings shown hereon are referenced to the centerline of Mediterranean East Q46,13�-s.e5'r having an Assumed bearing of NORTH, according to the Unrecorded plat of SPANISH LAKES PHASE I, of St. Lucie County, Florida. 2. All above ground fixed improvements, if any, have been located and shown hereon. EAS :� 110. 00 q 0 3. Underground utilities and utility services have not been located on this survey. EXISTING MOBILE HOME J 4. Flood Note: B graphic plotting only, this property Is in Zone "X", according to the Y9 P P 9 Y. P P Y� 9 Flood Insurance Rate Map, Community Panel No. 12111CO280 F effective date May 74 4, 1989. The exact designation can only be determined by an elevation certificate. (OCCUPIED) 5. Reproductions of this map are not valid without the signature and original raised seal of a Florida Licensed Surveyor & Mapper. 6. Lands shown hereon were not abstracted by this office for rights —of —way, easements of record, ownership, abandonment's deed restrictions, or Murphy Act Deeds. 7. The last date of field work was June 21, 2007. 8. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 9. The purpose of this map is to show the relationship of new structure to the existing structures, and the relationship of the average height of new structure to the Centerline of road. 10. Elevations shown hereon are in feet and are based upon assumed datum. CERTIFIED TO: Wynne Building Corp L Charles Amold Date Signed Professional Surveyor & Mapper Florida Certificate No. 4971 5peclfic Purpose Survey Location Of Formboard For: WYNNE BUILDING CORP. 5t. Lucie County, Florida File: 016.DWG CONSULTING ENGINEERS Date: 6/26/07 & FB: 0729/65 CULPEPPER & LAND SURVEYORS 06-472/016CT 2980 SOUTH 25th STREET Scale: 1"=20' TERPENING.INC. FORT PIERCE, 34981 4-35A (772) 464-3537 Drawn by. KPO Licensed Business No. 4286