Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS_2• t - - Wrlahts®fit® Load Shod Farm yob: Date: Mar 19, 2008 Entire House By: PREFERRED AIRCONDITIONING & MECHANICAL, Ind. o - a o For: ,:.. MOORNINGSIDE, CENTEX HOMES - MODEL -1702 SOUTH, ST LUCIE COUNTY, FL ®- ® o 0 Htg `. ' . .Clg.. - , . ,.. Infiltration Outside db (`F) 42 '90 Method Simplified Inside db (OF) 70 ' 75 Construction quality Average Design TD (OF) 28 15 Fireplaces 0 Daily range _ L Inside.humidity (%) 30 ' 50 , Moisture difference (gr/lb) 1 61 " HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade 13HPD Series Trade 13HPD Series 13HPD-042-2301 Model * Cond 13HPD-042-230/* Coil CB26UH-042-R* Efficiency 7A HSPF Efficiency . ' 13 EER Heating input Sensible cooling 29050 Btuh Heating output 41000 Bt6h @ 470F Latent cooling 12450 Btuh ' Temperature rise 27 °F Total cooling 41500, Btuh Actual air flow 1383 cfrh Actual air flow 1383 cfm Air flow factor .:` o.o48 d"Muh Airflow factor . 0.048 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 • in H2O Space thermostat" Load sensible heat ratio 0.78 ROOM NAME 29 0 Area (ft2) Htg load -(Btuh) Clg load (Btuh) Htg AVF (cfm) Clg'AVF. (cfm) FOYER .. 118.I 3645 1283 174 . 62 .- POWDER 50, 0 0 0 0 GREAT ROOM ' 272 ' 5001 2940. 239 141 DINING: 144 4153 2184 '198 105 KITCHEN 231 I 4150 5092 . 198 ' -244 WIC 3 - 30 , .824 595 39 29' . BEDROOM 3 ; . 143 `. 1730 4761. 83 226 BEDROOM 2 144, 1760 : 4728 . 85 227 . MASTER BATH 60 1537 1183 73 57 MASTER BEDROOM 224 , 2660 2954 127 142 WIC 1 56 477 441 23 21 BATH 2 48.1 84 225 LOFT .. 182 6 2505 141 120. Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 7 . -�-. wriiigt9�igs�ft' RightSuite Residential 6.0.119 RSR43667 2008rMar-19 09:43:13 lea Project2.rrp Calc = MJ8 - Orientation = N Page 1 t f Entire House d 1702 29002 28831 1383 1383 Other equip loads 2122 1137 Equip. @ . 0.95 RSM 28470 Latent cooling 8599 944n9 47r1G[] 44A1 1QS2'� TOTALS I i Printout certified by ACCA to meet all requirements of Manual J 8th Ed. pp��-�- wwri9hts®ft- Right -Suite Residential 6.0.119 RSR43667 200$-Mar-19 09:43:13 iK dk Project2.rrp Calc = MJ8 Orientation = N Page 2 -- wrightsoft° Right-J Worksheet Entire House PREFERRED AIR CONDITIONING & MECHANICAL, Inc. Job: Date: Mar 19, 2008 By: 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Entire House 254.0 ft 9.0 ft d 1701.8 ft2 FOYER 36.0 ft 9.0 ft heat/cool 9.1 x 13.0 ft 118.3 ft2 Ty Construction number lJ-value (Btuh/ft2--°F) Or HTWi (Btuhltt2) Area (ft') or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V1J 1�-GG 51A 1A-clom IA-ciomd 12B-Obw 1A-ciom 51A IA-clom 12B70bw 12B-Obw 1A-clom 1A-clom 1A-clom 51A 1111130 12B-Obw IA-clom 61A IA-clom 12B-0bm 11130 16A-19ad 22A-tph 0.116 1.270 1.270 0.097 1.270 0.116 1.270 0.097 0.097 1.270 1.270 1.270 0.116 0.290 0.097 1.270 0.116 1.270 0.122 0.290 0.049 1.358 n n n n n a a a s s s s s s w w w w - n - - 3.25 35.56 35.56 2.72 35.56 3.25 35.56 2.72 2'72 35.56 35.56 35.56 3.25 8.12 2.72 35.56 3.25 35.56 3.42 8.12 1.37 38.02 2.78 34.77 ' 34.77 1.47 27.82 2.78 72.90 1.47 1.47 30.30 30.30 30.30 ' 2.78 ` 8.41 1.47 72.90 2.78 82.01 1.07 8.41 3.55 0.00 252 23 40 252 30 297 23 339 243 6 15 12 180 20 297 46 225 0 249 18 922 1702 189 0 0 222 0 274 0 339 '210 6 15 12 160 20 251 0 225 0 231 18 922 132 614 818 1422 603 1067 890 818 921 570 213 533 427 520 162 682 1636 731 0 789 146 1264 5019 526 800 1391 327 835 763 1677 500 310 167 417 334 445 168 370 3353 626 0 248 151 3274 0 0 0 0 0 0 0 0 0 0 0 0 0 180 20 0 0 0 0 150 0 35 118 0 0 0 0 0 0 0 0 0 0 0 0 160 20 0 0 0 0 150 0 35 36 0 0 0 0 0 0 0 0 0 0 0 0 520 162 0 0 0 0 512 0 48 1369 0 0 0 0 0 0 0 0 0 0 0 0 445 168 0 0 0 0 161 0 124 0 V�1 t. G T--G W V,V Ilt----GGG V�! t-D NJ t-G V,V I--G q � ' D C F 6 c) AED excursion 0 -77 Envelope loss/gain 19845 16682 2611 822 12 a) Infiltration 2985 842 268 73 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 6 1380 0 0 Appliances @ 1200 1 1200 0 0 Subtotal (lines 6 to 13) 22830 20104 2869 895 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22830 20104 2869 895 15 Duct loads 27% 43% 6171 8728 27% 43% 776 388 Total room load 29002 28831 3645 1283 Air required (cfm) 1383 1383 174 62 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. r wrigo-v2sos t Right -Suite Residential 6.0.119 RSR43667 2008-Mar-19 09.43:13 ACCK Project2.rrp Calc = MJ8 Orientation = N Page 1 wright§oft=' Right-J Worksheet Entire House PREFERRED AIR CONDITIONING & MECHANICAL, Inc. Job: Date: Mar 19, 2008 By: 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area POWDER 0.0 ft 9.0 ft heat/cool 5.0 x 10.0 ft 50.0 ft2 GREAT ROOM 33.0 It 9.0 It heat/cool 17.0 x 16.0 ft 272.0 ftz Ty Construction number U-value (Btuh/ft� °F) Or HTM (Btuh/ftz) Area (ft) _ or perimeter (ft) Load (Btuh) Area (ft') or perimeter (it) Load (Btuh) Heat F Cool Gross N/P/S Heat Cool • Gross N/P/S Heat Cool . 6 11 V�J I-� 51A 1A-ciom IA-clomd 12B-0bw 1A-ciom 51A 1A-ciom 12B-06w 12B-0bw 1A-ciom IA-ciom IA-clom 51A 11 PO 12B-0bw IA-clom 51A - 1 A-cl om 12B-Obm 11 PO 16A-19ad 22A-tph 0:116 1.270 1.270 0.097 1.270 0:116 1.270 0.097 0.097 1.270 1.270 1.270 0.116 0.290 0.097 1.270 0.116 1.270 0.122 0.290 0.049 1.358 n n n n n a a a s s s s s s w w w w - n - - 3.25 35.56 35.56 2.72 35.56 3.25 35.56 2.72 2.72 35.56 35.56 35.56 3.25 8.12 2.72 35.56 3.25 35.56 3.42 8.12 1.37 38.02 2.78 34.77 34.77 1.47 27.82 2.78 72.90 1.47 1.47 30.30 30.30 30.30 2.78 8.41 1.47 72.90 2.78 82.01 1.07 8.41 3.55 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 144 0 40 0 0 0 0 0 0 0 0 0 0 0 0 0 153 0 0 0 0 272 104 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 153 0 0 0 0 33 338 0 1422 0 0 0 0 0 0 0 0 0 0 0 0 0 497 0 0 0 0 1255 290 0 1391 0 0 0 0 0 0 0 0 0 0 0 0 0 426 .0 0 0 0 0 C yJ t--G V�/ t-_ C W VV��JJ G . 11- W T-D 1IN G V�! ' G R t-D C F f i s 6 c) AED excursion 0 - -176 Envelope loss/gain 0 0 3512 1930 12 a) Infiltration 0 0 425 120 b) Room ventilation 0 0 0 .0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances Q 1200 0 0 0 0 Subtotal (lines 6 to 13) 0 0 3937 2050 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 3937 2050 15 Duct loads 27% 43% 0 0 27% 43% 1064 890 Total room load 0 0 5001 2940 Air required (cfm) 0 0 239 141 Pri -rit Right -Suite Residential 6.0.1?9 RSi ACCK Project2.rrp Calc = MJ8 Orientation = N 2008-Mar-19 09:43:13 Page 2 y - wrightaoft9 Right-J Worksheet -Entire House PREFERRED AIR'CONDITIONING & MECHANICAL, Inc. Job: Date: Mar 19, 2008 Bv: 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area DINING 31.0 It 9.0 ft heat/cool 12.0 x 12.0 ft 144.0 ft' KITCHEN 32.0 It 9.0 It heat/cool 21.0 x 11.0 ft 231.0 ft Ty Construction number U-value (Btuh/ft�°F) Or HTM (Btu fit) Area (W) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh)' Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V��f---G 51A IA-clom 1A-clomd 12B-0bw IA-clom 51A IA-clom 12B-0bw 12B-0bw IA-clom IA-clom IA-clom 51A 11 PO 12B-0bw IA-clom 61A 1A-clom 12B-0bm 11 PO 16A-19ad 22A-tph 0.116 1.270 1.270 0.097 1.270 0.116 1.270 0.097 0.097 1.270 1.270 1.270 0.116 6.290 0.097 1.270 0.116 1.270 0.122 0.290 0.049 1.358 n n n n n a a a s s s s s s w w w w - n - - 3.25 35.56 35.56 2.72 35.56 325 35.56 2.72 2.72 35.56 35.66 35.56 3.25 8.12 2.72 •35.56 3.25 35.56 3,42 8.12 1.37 38.02 2.78 34.77 34.77 1.47 27.82 2.78 72.90 1.47 r 1.47 30.30 30.30 30.30 2.78 8.41 1.47 72.90 2.78 82.01 1.07 8.41 3.55 0.00 108 23 0 0 0 108 0 0 0 0 0 0 0 0 0 0 72 0 0 0 0 144 85 0 0 0 0 108 0 0 0 0 0 0 0 0 0 0 72 0 0 0 0 31 276 818 0 0 0 361 0 0 0 0 0 0 0 0 0 0 234 0 0 0 0 1179 237 800 0 0 0 301 0 0 0 0 0 0 0 0 0 0 200 0 0 0 0 0 0 0 0 0 0 189 23 0 0 0 0 0 0 0 0 0 0 0 99 18 0 231 0 0 0 0 0 166 0 0 0 0 0 0 0 0 0 0 0 0 81 18 0 32 0 0 0 0 0 539 818 0 0 0 0 .0 0 0 0 0 0 0 277 146 0 1217 0 0 -0 0 0 462 1677 0 0 0 0 0 0 0 0 0 0 0 87 151 0 0 �-G yJ L-G 18/ L-_G w V,V " L-D l t---G R �--D C F 6 c) AED excursioh -131 -103 Envelope loss/gain 2857 1407 2997 2.274 12 a) Infiltration b) Room ventilation I 412 0 116 0 271 0 76 0 13 Internal gains: Occupants @ 230 ` Appliances @ 1200 ' 0 0 0 0 0 1 0 1200 Subtotal (lines 6 to 13) 3270 1523 3267 ; 3551 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 27% 43% 0 0 0 3270 884 0 0 0 1523 661 27% 43% 0 0 0 3267 883 0 0 0 3551 1541 Total room load Air required (cfm) 4163 198 2184 105 4150 198 5092 244 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. aim we igYvtsm�t- Right -Suite Residential 6.0.1 19 RSR43667 2008-Mar-19 09:43:13 ACCK Project2.rrp Calc = MJ8 Orientation = N Page 3 -+}} wriglhtsoft Right-i Worksheet Entire House . PREFERRED AIR CONDITIONING & MECHANICAL, Inc. Job: Date: Mar 19, 2008 By: 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area WIC 3 11.0 ft 9.0 ft heat/cool 5.0 x 6.0 ft 30.0 ft2 BEDROOM 3 11.0 ft 9.0 4 heattcocl 11.0 x 13.0 It 143.0 ft2 Ty Construction number U-value (Btuh/ft' °F) Or . HTM (Btuh/ft') Area (W) or perimeter(ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat . Cool 6 11 ltJ 51A 1A-clom IA-clomd 1213-0bw • IA-clom 51A 1A-clom 1213-0bw 12B-0bw 1A-clom 1A-clom IA-clom 51A 11 PO 12B-0bw 1A-clom 51A 1A-clom 12B-Obm 11 PO . 16A-19ad 22A-tph 0.116 1.270 1.270 0.097 1.270 0.116 1.270 0.097 0.097 1.270 1.270 1.270 .0.116 0.290 0.097 1.270 0.116 1.270 0.122 0.290 0.049 1.358 n n n n n a a a s s s s s s w w w w - n - - 3.25 35.56 35.56 2.72 35.56 3.25 35.56 2.72 2.72 35.56 35.56 35.56 3.25 8.12 35.56 3.25 35.56 3.42 .8.12 1.37 38.02 2.78 34.77 34.77 1.47 27.82 2.78 72.90 + -1.47 1.47 30.30 30-30 ' 30.30 2.78 8.41 1.47 72.90 2.78 82.01 1.07 8.41 3.55 0.00 0 0 0 0 0 0 0 0 54 6 0 0 0 0 45 0 0 0 0. 0 .30 30 0 0 0 0 0 0 0- 0 48 6 0 0 0 0 45 0 0 0 0 0 30 0 0 0 0 0 0 0 0 0 130 213 0 0 0 0 122 0 0 0 0 0 41 0 0 0 0 0 0 0 0 0 71 167 0 0 0 0 66 0 0 0 0 0 107 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 99 23 0 0 0 0 143 143 0 0 0 0 0 0 0 0 0 0 0 0 0 0 76 0 0 0 0 0 143 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 206 818 0 0 0 0 196 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 112 1677 0 0 0 0 508 0 �G 1/t/ -0 V�! t-G W UtJ �--D T-G2.72 V�I !. G q 1---D C F 6 c) AED excursion -36 481 Envelope loss/gain 5071 375 1220 2778 12 a) Infiltration 142 40 142 40 b) Room ventilation e 0 0 0 0 13 Intemal gains: Occupants @ - 230 0 0 2 460 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) - 649 415 1362 3278 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 649 415 1362 3278 15 Duct loads 270 43% 175 180 27% 43% 368 1423 Total room load 824 595 1730 4701 Air required (cfm) 39 29 83 226 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. t{ t wriigr.�ts®"FtRight-Suite Residential 6.0.119 RSR43667 2008-Mar-19 09:43:13 _ /CCJ'� Project2.rrp Calc = MJ8 Orientation = N Page 4 +�- wrightsoft° Right-J Worksheet°b Enure House Hate: 11Aar,s, Zoos .' By: PREFERRED AIR CONDITIONING & MECHANICAL,.inc. 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area BEDROOM 2 12.0 ft 9.0 ft heat/cool 12.0 x 12.0 ft 144.0 ff MASTER BATH 17.0 ft 9.0 ft I heaticool 5.0. x 12.0 ft 00.0 ft' Ty Construction number U-value (Btuh/ft2 °F) Or HTM (BtuhlfV) Area (ft') or perimeter (ft) Load (Btuh) Area OF) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool • Gross N/P/S Heat, Cool 6 11 V)J "A IA-c 1A-clomd 12B-0bw IA-clom 51A' 1A-ciom 12"bw 12B-0bw IA-clom .- IA-clom, 1A-616m '- 51A 11130. ,. IA-clom 51A ' 1A-clom 11PO . 16A-19ad 22A-tph 0.116 1.270 1.270 0.097 1.270 0.116 1.270 0.097 0.097 1.270 1.270 1.270 0.116 0.290 0.097 1.270 0.116 1.270 0.122 0.290 0.049 1.358 ' n n n n n a . e e, s s s .s s s w w w w ' n - - 3.26 36.56 35.66 2.72 35.56 3.25 -35.56 2.72 2.72 35.56 35.56 35:56 3.25 6.12 2.72 35.56 3.25 35.56 3.42 8.12 1.37 38.02 2.78 ' 34.77 34-77 . 1.47 27.82 2.78 ' 72.90 1.47 1.47 30.30 30.30 30.30 2.78 6.41 1.47 72.90 2.78 82.01 1.07 8.41 3.55 0.00 0 0 0 0 0 0 0 0 0 '. 0 . 0 0 _- 0 0 108 23 0 , 0 0 0 144 144 0 0 0 0 0 0 0 0 0 0 0 .0 0 0 85 0 0 0 0 0 144 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 231 818 0 0 0 0 198 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 125 1677 0 0 0 0' 512 0 0 0 0 108 15 0 0 0 0 0 0 0 0 0 45 0 0 0 0 0 60 60 0 0 0 93 0 0 0 .0 0 0 0 0 0 0 45 0 0 0 0 0 60 0 0 0 0 253 533 0 0 0 0 0 0 0 0 0 122 0 0 0 0 0 82 0 0 0 0 137 417 0 0 0 0 0 0 0 0 0 66 0 0 -0 .0 0 213 0 lE_-GG V�J L-( V�J �-G W W 1 G W r D YL128-0bw G t-G IL-12B-0bm C F r 6 c) AED excursion, 480 -71 Envelope loss/gain .- 1246 2793 991 763 12 a) Infiltration. 155 44 219 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 1401 3297 1210 Less eztemal load 0 0 0 0 Less transfer - 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1401 3297 1210 825 15 _ Duct loads 27% 43% 319 1431 27% 43% 327 368 Total room load' 1780 4728 1537 1183 Air required (cfm) 85 227 73 57 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. - wrigNts®sFe- Right -Suite Residential6.0.1"v9RSR43667 2008-Mar-1909:43:13 ACCK Prolect2.rrp Calc = MJe Orientation = N 1 Page 6 wrightsoft° Right-J Worksheet Entire House PREFERRED AIR CONDITIONING & MECHANICAL, Inc. Job: Date: Mar 1.9, 2008 By: 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area MASTER BEDROOM 30.0 ft 9.0 ft heattcool 16.0 x 14.0 ft 224.0 ft' WIC 1 8.0 ft 9.0 ft heattcool 8.0 x 7.0 ft 56.0 ft' Ty Construction number U-value (Btuh/ft2-"F) Or HTM (Btuh/ft') Area (ft2) or perimeter (ft) Load (Btuh) Area (it') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 Vl! 51A IA-clom IA-clomd 12B-0bw IA-ciom 51A IA-clom " 12B-0bw 12B-0bw IA-ciom IA-ciom IA-clom 51A 11 PO 12B-0bw IA-ciom 51A 1A-ciom 11130 16A-14ad 22A-tph 0.116 1.270 1.270 0.097 1.270 0.116 1.270 0.097 0.097 1.270 1.270 1.270 0.116 0.290 0.097 1.270 0.116 1.270 0.122 0.290 0.049 1.358 n n n n n a a a s s s s s s w' w w w - n - - 3.25 35.56 35.56 2.72 35.56 3.25 35.56 2.72 2.72 35.56 35.56 35.66 3.25 8.12 2.72 35.56 3.25 35.56 3.42 8.12 1.37 38.02 2.78 34.77 34.77 ` 1.47 27.82 2.78 72.90 1.47 1.47 . -30.30 30.30 30.30 2.78 8.41 1.47 72.90 2.78 82.01 1.07 8.41 3.55 0.00 0 0 0 144 15 0 0 168 0 0 0 0 0 0 0 0 0 0 0 . 0 224 224 0 0 0 129 0 0 0 168 0 0 0 0 0 0 0 0 0 0 0 0 224 0 0 0 0 350 533 0 0 456 0 0 0 0 0 0 0 0 0 0 0 0 307 0 0 0 0 190 417 0 0 248 0 0 0 0 0 0 0 0 0 0 0 0 796 0 0 0 0 0 0 0 0 72 0 0 0 0 0 0 0 0 0 0 0 0 56 56 0 0 0 0 0 0 0 72 0 0 0 0 0 0 0 0 0 0 0 0 56 0 0 0 0 0 0 0 0 196 0 0 0 0 0 0 0 0 0 0 0 0 77 0 0 0 0 0 0 0 0 106 0 0 0 0 0 0 0 0 0 0 0 0 199 0 L�_-GG VN _G T--G W Va/ L -D VN L-G V�J -G R L-D --12B-0bm C F 6 c) AED excursion -177 -26 Envelope loWgain 1647 1474 272 279 12 a) Infiltration 447 126 103 29 b) Room ventilation e 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances @ 1200 0 1 0 0 0 Subtotal (lines 6 to 13) 2094 2060 375 308 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2094 2060 . 375 308 15 Duct loads' 27% 43% 566 894 27% 43% 101 134 Total room load 2660 2954 477 441 Air required (cfm) 1271 1421 23 21 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +H wragav¢s®s¢- Right -Suite Residential 6.0.1')9 RSR43667 2008-Mar-19 09:43:13 Project2.rrp Calc = MJ8 Orientation -- N Page 6 wrightsoft, Right-J Worksheet Entire House . PREFERRED AIR CONDITIONING & MECHANICAL, Inc. Job: Date: Mar 19, 2008 By: 1 2 3 4 5 Room name Exposed wall Ceiling height - Room dimensions. Room area BATH 2 0.0 ft 9.0 ft heat/cool 48.0 ft s 8.0 x 6"0 ft LOFT 33.0 ft 9.0 ft heat/cool 181.5 ft 11.0 x 16.5 ft Ty Construction number U-value (Btuh/ft' T) Or HTIbi (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) . Area ' (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I NIP/S Heat I Cool ; 6 11 G 51A 1A-cicm IA-clomd 12B-0bw 51A 1A-clom 12B-0bw. 12B-0bw" M-clom 1A-clom 1A-clom 51A 11 PO 12B-0bw 1A-clom 51A 1A-clam 12B-0bm 11130 16A-19ad 22A-tph 0.116 1.270 1.270 0.097 1.270 0.116 1.270 0.097 0.097 1.270 1.270 1.270 0.116 0.290 0.097 1.270 0.116 1.270 0.122 0.290 0.049 1.358 n n n n ' n e. a a s s s s s s w w w w - n . - - 3.25 35.56 35.56 2.72 35.56 3.25 35.56 2.72 2.72 35.56 35.56 35.56 3.25 8.12 2.72 3&56 3.25 35.56 3.42 8.12 1.37 38.02 2.78 34.77 34.77 '1.47 27.82 2.78 72.90 '• 1.47 1.47 30.30 30.30 30.30 2.78 8.41 1.47 72.90 2.78 82.01 1.07 8.41 3.55 0.00 0 0 0 . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 48 48 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 48 0 0 0 0 '0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 66 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 171 0 0 0 0 0 0 0 0 99 189 0 15 12 0 0 0 0 0 0 0 0 182 182 0 0 0 0 0 0 0 99 162 0 15 12 0 0 0 0 0 0 0 0 182 0 0 0 0 0 0 0 0 269 440 0 533 427 0 0 0 0 0 0 0 0 249 0 0 0 0 0 0 0 0 146 239 0 417 334 0 0 0 0 0 0 .0 0 645 0 ►--G Vr �-clom VAl i G w �}1 '. D 1RJ T--G y/ _ t-G R t-D C F 6 c) AED excursion -14 -150 Envelope loss/gain 66 157 1918 _ 1630 12 a) Infiltration b) Room ventilation 0 0.. 0 0 412 0 116 0 13 Internal gains: Occupants @ 230 01. 0 0 0 Appliances @ 1206 0 0 0 0 Subtotal (lines 6 to 13) 66 157 2330 1747 Less external load 0 0 10 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 66 157 2330 1747 15 Duct loads 27% 43% 18 68 27% 43% 630 758 Total room load 84 225 2960 2505 Air required (cfm) 4 11 141 120 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +}f- a viifgY-ztsoft- Right -Suite Residential 6.0.119 RSR43667 2008-Mar-19 09:43:13 Project2.rrp Calc = MJ8 Orientation = N Page 7 SelayFaxvia pori COM1 crorn: 863 967 0137 3/2/2007 9:05:49 AM (gage I of 1) Mar 02 07 10:13a Fi Foil Compa u GG3 067 0137 P.1 MASONRY WALL SYSTEM VALUES Component R-Value Out Side Air Film 0.17 Stucco 6/8" 1 8"' Block . 1.11 31a;!" Furring 1.1 (2,it- O.C,) N-boils AA-2 Vapor Shield i4lgji Perm Reflective- Insulation an 3/4" Furring 4.1 112" Gypsum Wall E . 0.45 Inaide Air Film 0.68 Total R-Value 8.61 Total U-Value 0.116 'Theo R-Values shown are from the , ASH RAE Handbook of fundamentals eitc-apt for the insulation. FI-Foil's Insulations are tested to As,rwi standards and have SBCCI compliance Reports are avaiable "Rounded to whole number U-Vakie AA2 = 0.243 DATE 01/2901 PAGE 1 XCn- 469 SCE: X07-1#59 9Q. Umv+ersW Forest Pmductlif CENTEX HOMES MODEL 1702B Site Information: Project Customer: CENTEX HOMES Lot/Block: Address: City: Ft. Pierce Project Name:MODEL 1702B Model: MODEL 1702B Subdivision: MORNINGSIDE State: FL General Truss Engineering Criteria & Design Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2004/TPI2002 Design Program: MTek 20/20 6.3 Wind Speed: 130 mph Roof Load:20.0-15.0-10.0-10.0 Floor Load: 40.0-10.0-0.0-5.0 ID. QW9 1 X07-059 A01 01/29/00 26 X07-059 E5 01/29/08 2 X07-059 A02 01 /29/08 27 X07-059 E7 01/29/08 3 X07-059 A03 DI/29/08 28 X07-059 EJ7U 01/29/08 4 X07-059 A03A 01(29/08 29 X07-059 GE1 o1/2sro8 5 X07-059 A04 o1129/os 30 1 X07.059 HJ7U 01/29M 6 X07-059 A04A 01129/08 31 X07-059 K5 01/29/08 7 X07-059 A05 01 /2s/os 32 X07-059 K9 01/29/08 8 X07-059 A06 010/08 33 X07-059 V10 01/29/08 9 X07-059 B1 01/29/08 34 X07-059 V2 01/29108 10 X07-059 B2 01/29/08 35 X07-059 V2A 01/29/08 11 X07-059 B3 • 01/29/08 36 X07-059 V4 01/29/08 12 X07-059 B4 01W08 37 X07-059 V5 01/29108 13 X07-059 B5 0112WM 38 X07-059 V6 01/29108 14 X07-059 B6 01/29/08 39 X07-059 V8 01/29/08 15 X07-059 B7 01129VOs 40 1 X07-059 V9 01129/08 16 X07-059 B8 01/29= 41 X07-059 F01 01/29/08 17 X07-059 B9 01/29M 42 X07-059 F02 01/29/08 18 X07-059 C1 01/29/08 43 X07-059 F03 01/29/08 19 X07-059 C 1 A 01 WOB 44 X07-059 F04 01/29/08 20 X07-059 C3 01/29M 45 1 X07-059 F05 01/29/08 21 X07-059 C3A 01129/08 46 X07-059 F06 01/29/08 22 X07-059 C5 01/29ro8 47 X07-059 F07 01/29/08 23 X07-059 CJ1U 01/29/08 48 X07-059 FG1 D1129108 24 X07-059 CJ3U 01/29/08 49 X07-059 FG2 01/29/08 25 X07-059 CJ5U 01/20108 50 X07-059 FG3 01/29/08 The truss drawing(s) refrenced above have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by UFP-Ft.Pierces FL. Truss Design Engineer's Name: Julius Lee, License #34869 1455 Southwest. 4th Avenue Delray Beach, FL. 33444 "`� V.? �i `;�`I J ` NOTE: The seal on these drawings indicate acceptance of %' . � ,' professional engineering'responsibility solely for the truss , \ s r T of ��' components shown. a 1! 1 t'� j.A, The suitability and use of this component for any particular lt``1 D ��,o�.p',�,'� R .VP A building SIt s e 2responsibility of the building designer, perBONA; This package includes individual, dated truss design drawings and 0 Additional drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of Florida Board of Professional Engineers Rules. DATE 01/29/08 PAGE 2 •rip UL I UnhwW Forest Products° RE: X07-059 CENTEX HOMES MODEL 1702E Site Information: Project Customer: CENTEX HOMES Project Name:MODEL 1702B Lot/Block: Model: MODEL 1702E Address: Subdivision: MORNINGS IDE City: Ft. Pierce State: FL 51 X07-059 FG4 011,4108 52 X07-059 I F05 01/29/08 Job Truss Truss Type pty Ply MORNINGSIDE MASTERS PHASE II X07-459 A01 COMMON 4 1 Job Reference (optional_- Universla FF�o�rest Product, Inc. E359, Vero Beach, FI. 32967, James Shear------- ______ _ _____ ___ - 7.030 s Jan 3 2008 MiTek Indusfres, Inc. Tue Jan 29 10:15:41 2008 Page 1 -----14 0 - - ----4 -- -91 --- 212-13 --- f— _-..- - 2S 0--------- ----?9 0-Q 1-0-0 6-9-3 7-2-13 7-2-13 6-9-3 1-0-0 Scale: 1/4^=1' 5x5 = 5.00 )12 5 4x4 4 W 2 6 4x4 3 7 1 W 2 8 12 11 10 4x4 = 4x4 - f--- 9-9-0 -- - --—18-3-0 - -{ ------ 28-0-0 - ----I 9-9-0 8-5-15 9-9-0 ------- - Plate Offsets (X,Y): [4:0-3-0,Edge). [5:0-2-8,Edgje, [6:0-3-01Edge] -- --- --- - -- -- -- -- - LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.46 Vert(LL) -0.19 8-10 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.68 Vert(TL) -0.50 8-10 >558 180 BOLL 10.0 Rep Stress Incr YES WB 0.16 Horz(TL) 0.10 8 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 123lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-5-15 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-7-3 cc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1331/0-3-8, 8=1331/0-3-8 Max Horz2=118(LC 5) Max Uplift2=-430(LC 5), 8=-430(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2529/714, 3-1=-2154/581, 4-5=-2056/603, 5-6=-20561603, 6-7=-2154/581, 7-8=-2529/714, 8-9=0/27 BOT CHORD 2-12=-67612271, 11-12=-322/1513, 10-11=-322/1513, 8-10=.559/2271 WEBS 3-12=-5301319, 5-12=-200/679, 5-10=-200/679, 7-10=-530/319 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x6 MT20 unless otherwise Indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 430 lb upliff at joint 2 and 430 lb uplift at joint 8. LOAD CASE(S) Standard • Job Truss T uss Type Qty Ply 'MORNINGS DE MASTERS PHASE 11 X07-459 A02 2 1 Jab Reference o Clonal) — Universal Forest Product, Inc. E359, VeF6 Beach, Fl. 32967, James Shoaf 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:42 2008 Page I 1-0- 6-3-14 12-0-0 16-0-0 21-8-2 28-0- 1-0-0 6-3-14 5-8-2 4-0-0 5-8-2 6-3-14 1-0-0 Scale = 1:48.7 4x6 06 4 T2 5 5.00 P-2 3 W2 3 W W2 6 2 7 ----- ------- --- 4x6 = 11 10 9 4x6 5x6 - 6-10-1 14-0-0 2.1-1-15 --48-0-0 6-10-1 7-1-15 7-1-15 6-10-1 Plate Offsets (X,Y): [4_0-3:0 0-_1-12],[5:0-3-0,0-1-12], [10:0-3:9,0-3!9L_ — ---- --- LOADING(psq SPACING 2-0-0 CS1 DEFL In (loc) I/def] Ud PLATES GRIP TOLL 20.0 Plates Increase 1.25 TO 0.35 Vert(LL) -0.10 10 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.59 Vert(TL) -0.32 9-10 >999 180 BOLL 10.0 Rep Stress Incr YES WB 0.25 Horz(TL) 0.10 7 n/a n1a SCDL 10.0 Code FBC2004/TPi2002 (Matrix) Weight: 133 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-6-9 Do pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid calling directly applied or 7-11-9 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1331/0-3-8, 7=1331/0-3-8 Max Horz2=104(LC 5) Max UpIIft2=-415(LC 5), 7=-415(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27,2-3=-2607/661,3-4=-25141731,4-5=-1720/486,5-6=-2514f731,6-7=-2607/662,7-8=0/27 BOT CHORD 2-11=-616/2322, 10-11=-345/1691, 9-10=-31811691, 7-9=-512/2322 WEBS 3-11 =-391/256. 4-11 =-3061775, 4-1 0=-501206, 5-1 0=-50/206, 5-9=-3061775, 6-9=-3911256 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf: BODL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed Lumber DOI-=1 .60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4)'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise Indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 415 lb uplift it joint 2 and 415 lb uplift at joint 7. LOAD CASE(S) Standard Job X07-459 Truss A03 Truss Type HIP Oty Ply MORNINGSIDE MASTERS PHASE II - 1 1 Job Reference o __--_.__.__ ______ _—._- ____ 1-0- 5-7-2 18-0-0 1-0-0 5-7-2 4-4-14 8-0-0 10-0-0 7.030 s Jan 3 2008 MITek Industries, Inc. Tue Jan 29 10:15:42 2008 Page 1 22-4-14 28-0-0 29 0-Q 4-4-14 5-7-2 1-0-0 Scale = 1:48. 5x7 = 5x10 zz 4 5 IV 0 5x5 = 11 10 9 5x5 �_- 5x8 == 4x6 28-0-0 10-0-0 8-0-0 10-0-0 — ------------ -- - Plate Offsets (X,Y): [2:0-3-2,0-0-21, [7:0-3-2,0-0-2) LOADING(psf) SPACING 2-0-0 CSI DEFL In (too) Well L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.57 Vert(LL) -0.23 7-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.79 Vert(TL) -0.67 7-9 >494 180 BCLL 10.0 Rep Stress Incr YES WS 0.15 Horz(TL) 0.11 7 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 128lb LUMBER i--- _--- -- BRACING -- -- - --- -----_ TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-8 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 8-2-6 cc bracing. WEBS 2 X 4 SYP No.2 WEBS 1 Row at midpt 5-11 REACTIONS (Iblslze) 2=133110-3-8, 7=1331/0-3-8 Max Horz2=90(LC 5) - Max Uplift2=-398(LC 5), 7=-398(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0127, 2-3=-2543/674, 3-4=-2177/604, 4-5=-1977/592, 5-6=-2176/604, 6-7=-2543/674, 7-8=0/27 BOT CHORD 2-11=-590/2286, 10-11=-443/1977, 9-10=-443/1977, 7-9=-558/2287 WEBS 3-11=-3591242, 4-11=-36/450, 5-11=-155/156, 5-9=-54/450, 6-9=-359/242 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.( 3) Provide adequate drainage to prevent water pending. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise Indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 398 lb uplift at joint 2 and 398 lb uplift at joint 7. LOAD CASE(S) Standard Job > Truss Truss Type Toty Ply MORNINGSIDE MASTERS PHASE II 1 X07Y359 A03A SPECIAL 1 1 ---- - ------------- - --- ----- Job Reference Co bona Universal Forest Product, Inc. E359, Vero Beach, FI. 329T-, James Shoat 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:43 2008 Page 1 10-0-0 - .. - ---- 18-C-0 --- --- - ' { ---2-3-Q ---i -- - -- 28 — - - -9-�-� 1-0-0 5-7-2 4-4-14 8-0-0 3-3-0 6-9-0 1-0-0 • Scale = 1:49.5 5x7 = 4x6 C 4 5 6 5.00 12-----.------- --------- W3 W5 7 3 8 1 -.- - --- -- --- W4 - - „ - - - --- — 9 10� .- 2 6x10 - 9 r. Y / - B1 82------ 10 5x5 = 18 17 16 12 11 46 -� 5x8 - 5x5 = 4x6 10-0-0 17-11-8 21-3-0 28-0-0 10-0-0 7-11-8 3-3-8 6-9-0 Plate Offsets(X_Y)_[2:0-3-2,0-0-2],_[4:0-5_4,0.2-8], [6:0-3-4,0-1-12], [8:0-2.0,0-1-12i 9:0-1-6,0 0-2j�[11:0-2-0 0-2-0]�(13;03-0,�e],-[t4:0-2- 0_0-8 0-3-0],_[16;Edge,O_3.83J,, [17_0_2-8,0-3- LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.43 Vert(LL) -0.24 2-18 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.72 2-18 >459 180 BCLL 10.0 Rep Stress Incr YES WB 0.51 Horz(TL) 0.24 9 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 153 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-8-5 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-10-9 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1331/0-3-8, 9=1331/0-3-8 Max Horz2=90(LC 5) Max Uplift2=-398(LC 5), 9=-398(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2564/685, 3-4=-2148/588, 4-5=-2988/845, 5-6=-29991845, 6-7=-4554/1142, 7-8=-4446/1103, 8-9=-2674/669, 9-10=0/27 BOT CHORD 2-16=-595/2309, 17-18=-11/57, 16-17=010, 14-15=-629/2744, 13-14=-629/2744, 12-13=-19/62, 7-13=-91/77, 11.12=-66/161, 9-11=-562/2392 WEBS 3-18=-437/259, 4-18=-269/112, 15-17=0/111, 5-15=-255/135, 6-15=-89/447, 6-13=-45111892, 14-16=0/63, 8-11=-1580/395, 11-13=-612/2748, 8-13=-374/1757, 15-18=-42011956, 4-15=-348/1308 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) The Fabrication Tolerance at joint 13 = 12% 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 398 lb uplift at joint 2 and 398 lb uplift at joint 9. LOAD CASE(S) Standard Job Truss Truss Type Qty - Ply MOF X07-459 A04 HIP 1 1 Job Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf 7.030 s 1-0- 8-0-0 14-0-0 20-0-0 1-0-0 8-0-0 6-0-0 6-0-0 46 5x 10 MT181-1= 3 4 5x10 MT18H= 5 10 9 8 5x8 = 8-0-0 1-0-0 Scale = 1:48.7 8-0-0 14-0-0 20-0-0 28-0-0 8-0-0 6-0-0 6-0-0 8-0-0 Plate Offsets X Y : 2:0-1_6,0-0-2]16:0.1-6,0-0-21L[9:0 3-0,0-3-0]__ LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) Well Vd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.69 J Vert(LL) -0.12 9 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.70 Vert(TL) -0.41 6-8 >804 180 MT18H 244/190 BCLL 10.0 Rep Stress Incr YES WB 0.11 Horz(TL) 0.11 6 n/a n/a BCDL 10.0 Code FBC2004fTP12002 (Matrix) Weight: 122lb - - - ------ --- - LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-1-2 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 8-1-10 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1331/0-3-8, 6=1331/0-3-8 Max Horz2=-77(LC 6) Max Uplift2=-389(LC 3), 6=-389(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0127, 2-3=-25021700, 3-4=-2576/821, 4-5=-25761821, 5.6=-2502/700, 6-7=0/27 BOT CHORD 2-10=-558/2208, 9-10=-556/2216, 8-9=-56612216, 6-8=-56712208 WEBS 3-10=01329, 3-9=-163/577, 4-9=-374/194, 5-9=-1631577, 5.8=0/329 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise Indicated. 6) All plates are 4x4 MT20 unless otherwise Indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 389 lb uplift at joint 2 and 389 lb uplift at joint 6. LOAD CASE(S) Standard Job Truss Truss Type --------- --- Oty Ply MASTERS PHASE If X07-4591 A04ASPECIAL I[�MORNINGSIDE ' Universal Forest Product, Inc. E359. Vero Beach, FI. 32967, James Shoat __ _ __ Job Reference (optional) _ -- --�� - -- --- 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:43 2008 Page 1 T1-0-0 -8-0--0 — [ -- -- - 2 20-0-0 1-3-0 24-3-10 28-0-0 9-0- Q4— —T-- 1-0-0 8-0-0 4-11-12 4-11-12 2-0-8 1-3-0 3-0-10 3-8-6 1-0-0 Scale = 1:49. 5x10 = 46 3 5.00 12 4 5 6 ---��--------- —..__ — - -- ._...----- -----. 7 W3 W5 2 Wig , W4 2 6x10 -- 6x10 = 910 Iv - Io 46 = 18 17 16 15 12 11 4x6 =' 4x6 = 4x6 5x8 = 8-0-0 � 12-11-12 17=11-8 _� 20 0 121-3-0� 24-3-10 �28-0-0 8-0-0 4-11-12 4-11-12 2-0-8 1-3-0 3-0-10 3-8-6 Plate OffsetslX,YZ[2:0-1-10 0-0-2h [6:0-3-0,0.1-121, 9[ •0-1-6 0.0-2 111:0-2-8,0-2-0], [13:0-2-8,Edge], [14:0-3-12,0-3-01 [15:Edge,0-3-8], [IL —1=12,0-2-8] LOADING(psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 CSI TC 0.64 DEFL in floc) I/def] Ud Vert(LL) -0.21 13-14 >999 360 PLATES GRIP MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vart(TL) -0.60 13-14 >555 180 BCLL 10.0 Rep Stress Incr YES WB 0.45 Horc(TL) 0.23 9 We n/a BCDL 10.0 Code FBC2004/TP12002 --- (Matrix) -- Weight: 146 Ito LUMBER BRACING __--- -------'--- -- --- TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-9-2 cc puriins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-9-9 cc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) .2=1331/0-3-8, 9=133110-3-8 Max Horz2=77(LC 5) Max Uplift2=-389(LC 3), 9=-389(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2495/698, 3-4=-2553/811, 4-5=-3818/1142, 5-6=-3875/1144, 6-7=-4464/1250, 7-8=-1424/1213, 8-9=-27011729, 9-10=0/27 BOT CHORD 2-18=-555/2200, 17-18=-553/2208, 16-17=-553/2208, 15-16=-46/216, 14-15=0/116, 5-14=-241/130, 13-14=-865/3391, 12-13=-7/88, 7-13=-86/76, 11-12=-58/221, 9-11=-625/2425 WEBS 3-18=0/316, 3-16=-163/580, 4-16=-871/305, 14-15=-667/2423, 4-14=-359/1375, 11-13=-624/2425, 8-13=-406/1615, 8-11=-1008/297, 6-14=-220/726, 6-13=-321/1302 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 44 MT20 unless otherwise Indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 389 Ib uplift at joint 2 and 389 lb uplift at joint 9. LOAD CASE(S) Standard 1 Job Truss Truss Type Oty Ply MORNINGSIDE MASTERS PHASE II X07A59 A05 HIP II Job Reference o tp ionaD_—___ _.__. ___ Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoat - 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15A 2008 Pago 1 11046-0-0 11-4-0 16-8-0 22-0-0 28-0-0 _ _.—_--- __ 29-0-q 1-0-0 6-0-0 5-4-0 5-4-0 5-4-0 6-0-0 1-0-0 Scale = 1:48. 5x7 = 5x7 5.00 12 3 4 5 6 --- -T'2 — ----- 2 1 _-- ---' '- - --- --- - - - ----- '-'-- — --' - t�- __'--_--- - — 7 8 4x14 = 11 10 9 4x14 5x10 MT18H= 6-0-0 14-0-0 22-0-0 28-0-0 6-0-0 8-0-0 8-0-0 6-0-0 Plate Offsets (X,Y)_12:0-0-9,Edgej, [3:0-3_4,0-2-81 (6:0-3.4,0-2-8], [7 0-0-9,Edge],- 9[ '0-1-12,0-2-P�[10:0-5-0,0-3-A [11:0_1-12,0-2-0]_ LOADING(psf) TCLL 20.0 SPACING 2-0-0 CSI Plates Increase 1.25 TC 0.99 DEFL In (loc) Well L/d Vert(LL) 0.41 10 >816 360 PLATES GRIP MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.76 Vert(TL) -1.03 10-11 >324 180 MT18H 244/190 BCLL 10.0 Rep Stress Incr NO WB 0.33 Horz(TL) 0.26 7 n/a n/a BCOL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 122 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2 X 4 SYP SS BOT CHORD Rigid telling directly applied or 4-2-14 cc bracing. WEBS 2 X 4 SYP No.2 WEBS 1 Row at midpt 4-11. 5-9 REACTIONS (lb/size) 2=2422/0-3-8, 7=242210-3-8 Max Harz2=63(LC 5) Max Uplift2=-862(LC 3), 7=-862(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-5283/1947, 3.4=-4850/1841, 4-5=-6793/2546, 5-6=-4850/1841, 6-7=-5283/1947, 7-8=0/27 BOT CHORD 2-11=-1717/4783, 10-11=-2499/6632, 9-10=-2502/6632, 7-9=-1729/4783 WEBS 3-11=-290/1195,4-11=-2081/853,4-10=0/342,5-10=01342,5-9=-2081/853,6-9=-290/1195 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise Indicated. 6) All plates are 4x4 MT20 unless otherwise Indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 862 ib uplift at Joint 2 and 862 lb uplift at joint 7. 8) Girder carries hip end with 6-M end setback. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 315 lb down and 199 lb up at 22-0-0, and 315 ib down and 199 lb up at 6-0.0 on top chord. The design/selection of such connection device(s) Is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plo Vert: 1-3=-70, 3-6=-135(F=-65), 6-8=-70, 2-7=-39(F=-19) Concentrated Loads (Ib) Vert: 3=-315(F) 6=-315(F) o Truss Truss Type Oty Ply MORNINGSIDE MASTERS PHASE II XUniversal r3 Industries 1 Forest Product, Inc. E359 Vero Beach FI, 32967, James Shoaf , 200MiTeek 7. 30 aJan Inc. Tue Jan 29 10:15:44 2008 Page k n 9 1-0-0 6-0-0 5-4-0 5-4-0 5-4-0 6-0-0 1-0-0 Scale = 1:48.7 5x8 = 5x8 zz 5.00 F1-2 3 12 4 5 13 14 6 Ig i 4x14 = 11 15 16 17 18 10 19 20 21 22 9 4x14 = 5x5 = 7x10 MT18H= 5x5 = s-o-o 14-0-0 22-0-0 28-0-0 6-0-0 8-0-0 8-0-0 6-0-0 PlateOffsets X,Y1: [2:0-0-9,Edge],17:0-0-9,Edge1, [9:0-2-0,0-2-12] [10:0-5.0 0-5-0][11:0-2-42-4,0-2-12] LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) I/deft Ud—' PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.80 Vert(LL) 0.48 10-11 >688 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.92 Vert(TL) -1.14 10-11 >293 180 MT18H 244/190 BCLL 10.0 Rep Stress Incr NO WB 0.44 Horz(TL) 0.21 7 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 145 lb LUMBER -- ---------------- --- BRACING -- ---- -- - ----------.....--- TOP CHORD 2 X 4 SYP No.2 'Except* TOP CHORD Structural wood sheathing directly applied or 1-10-7 oc purlins. T2 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 4-6-0 oc bracing. BOT CHORD 2 X 6 SYP SS WEBS 1 Row at midpt 4-11, 5-9 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=289310-3-8, 7=2815/0.3-8 Max Horz2=-66(LC 6) Max Uplift2=-1115(LC 3). 7=-1092(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/32,2-3=-6828/2656,3-12=-6334/2520,4-12=-6334/2520,4-5=-9211/3687,5-13=-6035/2408,13.14=-6035/2408, 6-14=-6036/2408, 6-7=-6509/2537, 7-8=0/32 BOT CHORD 2-11=-2378/6225,11-15=-3346/8517,15-16=-3346/8517,16-17=-334618517,17-18=-3346/8517,10-18=-3346/8517,10-19=-3374/8504,19-20=-3374/8504, 20-21=-3374/8504, 21-22=-3374/8504,9-22=-3374/8504,7-9=-2283/5935 WEBS 3-1 1=-598/1860,4-1 1=-251211033,4-1 0=-348/977, 5-10=-306/983, 5-9=-2810/1183, 6-9=-521/1695 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3,Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 4x6 MT20 unless otherwise Indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1115 lb uplift at joint 2 and 1092 lb uplift at joint 7. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 280 lb down and 219 lb up at 6-0-0. 133 lb down and 110 lb up at 8-0-12. 133 lb down and 110 lb up at 17-11-4, and 124 lb down and 101 lb up at 19-11-4, and 320lb down and 219 lb up at 22-0-0 on top chord, and 313 lb down and 67 lb up at 6-0-0, 76 lb down at 8-0-12, 268 lb down and 115lb up at 9-6-12, 274 lb down and 121 lb up at 10-9-0, 274 lb down and 121 lb up at 12-9-0, 274 lb down and 121 lb up at 14-9-0, 268 lb down and 115 lb up at 15-11-4, 76 lb down at 17-11-4, and 76 lb down at 19-11-4. and 313 lb down and 67 lb up at 21-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-6=-70, 6-8=-70, 2-7=-20 Concentrated Loads (lb) Vert: 3=-280(F) 6=-280(F) 11=-312(F) 9=-312(F) 12=-133(F) 13=-133(F) 14=-124(F) 15=-38(F) 16=-268(F) 17=-274(F) 18=-274(F) 19=-274(F) 20=-268(F) 21=-38(F) 22=-38(F) " IX07-459 61 HIP I� universal Forest Product, Inc. E359, Vero Beach, FI 32967, James Qty Ply MORNINGSIDE MASTEF 1 1 Job Reference (optional) 7.030 s Jan 3 2008 MiTek Ir in 29 10:15:45 2008 Page 1-0-0-0-0, 3-6-8 6-0-0 10-8-8 15-5-0 1 7-10-8 21-5-0 22-5-0 1-0-0 3-6-8 2-5-8 4-8-8 4-8-8 2-5-8 3-6-8 1-0-0 Scale = 1 3.00 FIT 04 II 3 11 12 4 13 14 5 a 2 0 15 16 9 17 18 5x10 MT18H== 2 W 6 _ -- 7 8 — 4x4 II 3-6-8 6-0-0 10-8-8 15-5-0 17-10-8 21-5-0 3-6-8 2-5-8 4-8-8 4-8-8 2-5-8 3-6-8 Plate Offsets (X,Y): [2:0.4-9,Edd el, 3] [ .0-7-0,0-2-12 , [5:0-7-0,0-2-12]�&0 4-9,Edga , [9:0.5-0,0-3-01 ' LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.83 Vert(LL) 0.41 9 >612 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.69 Vert(TL) -1.05 9 >238 180 MT18H 244/190 SCLL 10.0 Rep Stress Incr NO WB 0.27 Horz(TL) 0.20 6 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 86 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 "Except' TOP CHORD Structural wood sheathing directly applied or 1-10-4 oc purlins. T2 2 X 4 SYP No.1 BOT CHORD Rigid ceiling directly applied or 4-8-4 oc bracing. BOT CHORD 2 X 4 SYP SS WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1906/0-7-8, 6=1906/0-7-8 Max Horz2=37(LC 5) Max Uplift2=-732(LC 3), 6=-732(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16,2-3=-6073/2159,3-11=-7128/2601,11-12=-7128/2601,4-12=-7128/2601,4-13=-7128/2601,13-14=-7128/2601,5-14=-7128/2601,5-6=-6073/2160,6-7=0/16 BOT CHORD 2-10=-2060/5817, 10-15=-2064/5B63, 15-16=-2064/5863, 9-16=-2064/5863, 9-17=-2033/5863, 17-18=-2033/5863, 8-18=-2033/5863, 6-8=-2029/5817 WEBS 3-10=-47/589, 3-9=-552/1455, 4-9=-658/352, 5-9=-553/1455, 5-8=-48/589 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp S; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.6( 3) Provide adequate drainage to prevent water ponding. 4) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads, 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 5x10 MT20 unless otherwise Indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 732 lb uplift at joint 2 and 732 lb uplift at joint 6. 8) Hanger(s) or other connection device(s) shall be provided sufeclent to support concentrated load(s) 262 lb down and 159lb up at 6-0-0, 116 lb down and 81 lb up at 8-0-12, 116 lb down and 81 lb up at 10-0.12, 116 lb down and 81 lb up at 11-4-4, and 116 lb down and 81 lb up at 13-4-4, and 262 lb down and 159 lb up at 15-5-0 on top chord, and 350 lb down and 82 lb up at 6-0-0, 73 lb down at 8-0-12, 73 lb down at 10-0-12, 73 lb down at 11-4-4, and 73 lb down at 13-4-4, and 350 lb down and 82 lb up at 15-4-4 on bottom chard. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard 4) Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert 1-3=-70, 3-5=-70, 5-7=-70, 2-6=-20 Concentrated Loads (lb) Vert: 3=-222(F) 5=-222(F) 10=-350(F) 8=-350(F) 11 =-1 1 6(F) 12=-1 16(F) 13=-1 16(F) 14=-1 16(F) 15=-36(F) 1 6=-36(F) 17=-36(F) 1 B=-36(F) X07-459 Universal For 1-0-0 B2 HIP 1 1 359. Vero Beach, FI. 32967, James Shoaf -- --- — — 7.030 s 8-0-0 13-5-00 8-0-0 5-5-0 5x10 = 5x6 3.00 12 3 4 e a r 44 11 4x4 = 8-0-0 1-0-0 Scale = —5-0-0 -- -I-- 13-5-0 -- — I ------ --- 21-5-0 -- ---- --- I 8-0-0 5-5-0 8-0-0 Plate Offsets (X,Y)_[3:0-6-0,0-2-81, [4:0-3.0,0-3-01 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.59 Vert(LL) 0.14 2-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.47 2-9 >531 180 '— BCLL 10.0 Rep Stress Incr YES WB 0.11 Horz(TL) 0.09 5 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Welght: 81 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-1-9 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-3-14 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1030/0-7-8, 5=1030/0-7-8 Max Horz2=45(LC 5) Max Uplift2=-382(LC 3), 5=-382(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-2521/761, 3.4=-2386/768, 4-5=-2521/760, 5-6=0/16 BOT CHORD 2-9=-703/2374, 8-9=-701/2385, 7-8=-701/2385, 5-7=-665/2374 WEBS 3-9=0/274, 3-7=-252/253, 4-7=-4/274 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60: 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x6 MT20 unless otherwise Indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 382 lb uplift at joint 2 and 382 lb uplift at joint 5. LOAD CASE(S) Standard X07-459 B3 HIP 1 1 Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf __� ---`---7,030 s 1-0-0 5-4-14..—.__ 10 0-0 11-5-0 16-0-2 1-0-0 5-4-14 4-7-2 1-5-0 4-7-2 46 = 5x7 = 3.00 R12 4 5 _21-5-0 -I--225 -0 - -- - ---- 01 5-4-14 1-0-0 Scale = 1:38.i 46 = '" ' 4x6 = 5x10 = 10-0-0 10-0-0 1-5-0 10-0-0 LOADING(psf) SPACING 2-0-0 CSI DEFL In (too) /deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.38 Vert(LL) -0.21 7.9 >999 360 MT20 244/190 TCDL 15.0 Lumberincrease 1.25 BC 0.83 Vert(TL) -0.63 7-9 >396 180 BCLL 10.0 Rep Stress Incr YES WB 0.25 Horz(TL) 0.10 7 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 93 lb LUMBER BRACING BRACING ----'--- - ----- '- ------ — ----`- TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-5-7 oc purllns. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-1-1 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1030/0-7-8, 7=1030/0-7-8 Max Horz2=-54(LC 6) Max Uplif2=-371(LC 3), 7=-371(1-C 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-2704/836, 3-4=-2088/569, 4-5=-1985/575, 5-6=-2073/565, 6-7=-2702/837, 7-8=0/16 BOT CHORD 2-10=-798/2582, 9-10=-464/1986, 7-9=-754/2580 WEBS 3-10=-636/323, 4-10=-72/320, 5-10=-164/159, 5-9=-43/323, 6-9=-648/327 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber D0L=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 44 MT20 unless otherwise Indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2 and 371 lb uplift at joint 7, LOAD CASE(S) Standard Jab Truss Truss Type X07-459 B4 COMMON Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf _ 5-10-12 ---F-- -- 10-5-8 - -- 5-10-12 4-9-12 4x6 = 3.00 12 3 4x6 :_ t.UJU s Jan J zuud MI I ex'InaustneS, Inc. I ue Jan ZB 1U:1 0:4b ZUUtl rag 15-6-4 21-5-0 22-5-0 4-9-12 5-10-12 1-0-0 Scale = 1:: 21-5-0 6-3-15 LOADING(psf) SPACING 2-0-0 CST DEFL In (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.32 Vert(LL) -0.17 7-9 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.58 7-9 >427 180 BCLL 10.0 Rep Stress Incr YES WB 0.17 Horz(TL) 0.09 5 n/a n/a BCDL 10.0 Code FBC2004/rPI2002 (Matrix) Weight: B5 lb ------- --- LUMBER BRACING - --- --- -- ------ -- -- - TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3.5-8 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-1-14 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=933/0-7-8, 5=1033/0-7-8 Max Horz 1=-61(LC 6) Max Upliftl=-279(LC 3), 5=-367(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-2803/797, 2-3=-2685/795, 3.4=-2658/763, 4-5=-2776/764, 5-6=0/16 BOT CHORD 1-9=-761/2661, 8-9=-466/1803, 7-8=-466/1803, 5-7=-682/2632 WEBS 2-9=-330/197, 3-9=-280/935, 3-7=-253/906, 4-7=-321/189 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise Indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 279 lb uplift at joint 1 and 367 lb uplift at joint 5. LOAD CASE(S) Standard Job Truss Truss Type ty Ply Oty ---_- ----._.._---- MORNINGSIDE MASTERS PHASE 11 X07-459 B5 COMMON 1 �Ao—bRie—fe�enoe —Forest -Beach, (oPA!q-nJaI Universal Product, T—n6--E359, Vero Fl. 32967, James Shoaf 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:46 2006 Page 1 5-1 0-12____ 21-5-0 22-5-0 5-10-12 4-9-12 4-9-12 5-10-12 1-0-0 Scale = 1:35.7 46 3.00112 3 2 W 2 4 5 6 4x6 = 9 8 7 4x6 4x6 6-3-15 15-1 -1 21-5-0 6-3-15 8-9c2 6-3-15 LOADING(psf) TCLL 20.0 SPACING 2-M CS1 DEFL in (loc) Plates Increase 1.25 TC 0.32 Vert(LL) -0.17 7-9 I/defi Ud PLATES GRIP >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.58 7-9 >427 180 BCLL 10.0 Rep Stress Incr YES WB 0.17 Horz(TL) 0.09 5 n1a n1a BCDL 10.0 Code FBC20041TPI2002 (Matrix) Weight: 85 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-5-8 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-1-14 oc, bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=933/0-7-8,5=1033/0-7-8 Max Horz 1 =-61 (LC 6) Max Upliftl =-279(1-C 3), 5=-367(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-26031797,2-3=-2685/795,3-4=-2658f763,4-5=-2776/764,5-6=0/16 BOT CHORD 1-9=-76112661, 8-9=-46611803, 7-8=-466/1803, 5-7=-682/2632 WEBS 2-9=-330/197, 3-9=-280/935, 3-7=-253/906, 4-7=-321/189 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf*, BCDL=3.Dpsf,, Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise Indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 279 lb uplift at joint 1 and 367 lb uplift at joint 5. LOAD CASE(S) Standard I X07-459 I B6 SPECIAL 11 1 s 3-11-4 6-10-0 __ 10-6-4 13-10 8. 17-2-12 22-0-8 27-11-4- 8-11- 3-11-4 2-10-12 3-8-4 3-4-4 3-4-4 4-9-12 5-10-12 1-0-0 Scale = 1:47 4x6 6 15 17 14 13 12 11 10 5x8 = 5x8 = 46 =- 3-11-4 6-10=0 T 0-6-4 12-10-2 21-7-6 27-11-4_- 3-11-4 2-10-12 3-8-4 2-3-14 8-9-3 6-3-14 LOADING(psf) SPACING 2-01 CSI TCLL 20.0 Plates Increase 1.25 TC 0.74 TCDL 15.0 Lumber Increase 1.25 BC 0.64 BCLL 10.0 Rep Stress Incr NO WB 0.58 BCDL . 10.0 Code FBC2004/TP12002 (Matrix) DEFL in (loc) I/deft Ud Vert(LL)-0.1610-12 >999 360 Vert(TL)-0.5010-12 >499 180 Horz(TL) 0.05 8 nla n/a PLATES GRIP MT20 244/190 Weight: 120 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-9-15 oc purlins. BOT CHORD 2 X 4 SYP No.2 SOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2 X 4 SYP No.2 - REACTIONS (lb/size) 1=38/0-6-12, 14=182410-7-8, 8=926/0-7-8 Max Harz1=-61(LC 6) Max Upliftl=-37(LC 5), 14=-569(LC 3), 8=-340(LC 4) Max Gravl=90(LC 7), 14=1824(LC 1), 8=926(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-64/454, 2-16=-516/1839, 3-16=-516/1839, 3-4=-516/1839, 4-5=-1640/448, 5-6=-1670/494, 6-7=-22521662, 7-8=-2370/663, 8-9=0/16 BOT CHORD 1-15=-402/80, 15-17=-392/84, 14-17=-392184, 13.14=-254/836, 12-13=-2581850, 11-12=-345/1392, 10-11=-345/1392, 8.10=-584/2241 WEBS 2-15=0/191, 2-14=-1535/506, 3-14=-369/170, 4-14=-2777/816, 4-13=-101/28, 6-12=-86/374, 6-10=-256/921, 7-10=-330/191, 5-12=-275/150, 4-12=-168/815 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 37 lb uplift at joint 1, 569 lb uplift at joint 14 and 340 lb uplift at joint B. . 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 213 lb down and 106 lb up at 3-11-4, and 79 lb down and 36 lb up at 6-0-0 on top chord, and 90 lb down at 3-11.4. and 33 lb down at 6-0-0 on bottom chord. The design/selection of suchconnection device(s) is the responsibility of others. 3) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 - Uniform Loads (plf) Vert: 1-2=-70, 2-4=-70, 4-6=-70, 6-9=-70, 1-8=-20 Concentrated Loads (lb) Vert: 2=-133(F) 15=-43(F) 16=-39(F) 17=-16(F) B7 I SPECIAL I 1 1 1 al For Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf 7.030 s Jan 3 2008 MiTek Industries, Inc Tue Jan 29 10:15:47 2006 Page —__ 5-11-4 12-6-4 _ _ -_.- 17_2-12 __-_-_- 22-0-8 27-11-4 8-11- -+ - i ----------- + - --- --- -- --- -' ---- 5-11-4 6-7-0 4-8-8 4-9-12 5-10-12 1-0-0 Scale = 1;47. ann1-1-9 4 a �m 6 4x4 II 5x7 WB= 5X10 = 5-11-4 12-6-4 21_7-6 27-11 4 5-11-4 6-7-0 9-1-2 6-3-14 r,a,c vpa`_1 ). r1.U-J-WGUVGf, rcu--u u-0, V-0-yu-4-1 Z l4:V-4r14,U-c-0ho:e-v-a,r.o9.J,1a:u-a-e,U-4-4L La:V-J-V,o_z_aJ_— LOADING(psf) SPACING 10-0� CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.91 Vert(LL) 0.44 8-9 >743 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.93 Vert(TL) -1.35 8-9 >242 180 BCLL 10.0 Rep Stress Incr YES WB 0.57 Horz(TL) 0.17 6 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 116 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=1228/0-6-12, 6=1327/0-7-8 Max Horz 1=-61(LC 6) Max Upliftl=-388(LC 3), 6=-424(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-3950/1234, 2-3=-5470/1645, 3-4=-5845/1790, 4-5=-378411008, 5-6=-3899/1004, 6-7=0/16 BOT CHORD 1-11=-1185/3773, 10-11=-1182/3785, 9-10=-1182/3785, 8-9=-815/2930, 6-8=-934/3715 WEBS 2-11=0/235, 2-9=-436/1732, 3-9=-1764/634, 4-9=-975/3099, 4-8=-242/885, 5-8=-295/182 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.( 3) Provide adequate drainage to prevent water ponding. 0) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. i) All plates are 5x7 MT20 unless otherwise Indicated. 3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 388 lb uplift at joint 1 and 424 lb uplift at joint 6. LOAD CASE(S) Standard • IX07.459 0 5x6 = Truss —�TTruEssType M0RNINGSIDE MASTERS PHASE II Oty PlyjJob Ba AL 1 Reference�otonal 31 Forest Product, Inc. E369, Vero Beach, Fl. 32967, James Shoaf 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue_Ja_n 29 10.15.47 2008 Page 7-11-4 14-6-48-11- 7-11-4 6-7-0 2-8-8 4-9-12 5-10-12 1-0-0 Scale = 1:47. 4x6 = 3.00 12 500 = 4x6 = 4 11 10 9 8 5x6 = 5x8 — 46 -= 7-11-4 _ 14-6-4 21-7-6 27-11-4 7-1 1-4 6-7-0 7-1-2 6-3-14 Plate Offsets X,Y-L[1:0-3-13,Edge]_ 2[ ,0 4-12,0-2:8J,_[3:0_2-8_0-2-4][4_0-2.8,0-2-0] [6:0.4_9,Edge] LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.76 Vert(LL) -0.30 10 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.94 Vert(TL) -0.90 8-10 >365 180 BCLL 10.0 Rep Stress [nor YES WB 0.34 Horz(TL) 0.17 6 nla n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 115 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-3-5 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=1228/0-6-12, 6=1327/0.7-8 Max Horz1=-61(LC 6) Max Upliftl=-388(LC 3), 6=-423(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-3732/1154, 2-3=-4172/1256, 3.4=-441B/1350, 4-5=-3756/1015, 5-6=-3872/1011, 6-7=0/16 BOT CHORD 1-11=-1094/3549,10-11=-1092/3562,9-10=-800/2928,8-9=-800/2928,6.8=-942/3691 WEBS 2-11=0/309, 2-10=-190/640, 3-10=-1339/484, 4-10=-591/1845, 4-8=-257/836, 5-8=-306/185 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip D0L=1 3) Provide adequate drainage to prevent water ponding. 4) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise Indfcated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 388 lb uplift at joint 1 and 423 lb uplift at Joint 6. LOAD CASE(S) Standard • Job a _-------- T as Truss ----------------- OTy— Ply ST PHASE II X07-459 B9 ]SPECIAL 1 Job Refe ence �oplonaERS ----- — -- -_ Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf 7,030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 1615:4722008 Page y I 5-4-2 - -- {-- 9 11 4--- -f ---- 7_ 16 6— 4 — t - -- 22 0 8 - +— -- 27 11-4 5-4-2 4-7-2 6-7-0 0-8-8 4-9-12 5-10-1 2 1-0-0 Scale = 1:47 46 = _ sx6 = � 3.00 F12 5x8 9 4 5 5x8 = 4x6 -_ 9-11-4 16-6.4 21-7-5 27-11-4 9-11-4 6-7-0 5-1-1 6-3-15 Plate Offsets-(X,Y): [1:0-3-13,Edggj13_0-3-0,0-2-12], [4:0-5-4 0-3-4]_L0-3.0,0-1-121�j7_0.4.9,Edg, [10:0-1-12,0-L01_ T LOADING(psf) SPACING 2-M CSI DEFL in (loc) Ildefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.50 Vert(LL) -0.25 1-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.93 Vert(TL) -0.83 1-12 >394 , 180 BCLL 10.0 Rep Stress Incr YES WB 0.24 Horz(TL) 0.17 7 n/a n/a BCDL 10.0 Code FBC2004(TP12002 (Matrix) Weight: 123 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-8-11 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=122810-6-12, 7=1327/0-7-8 Max Horz1=-61(LC 6) Max Uplift1=-388(LC 3), 7=A21(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-3795/1241, 2-3=-3286/1008, 3-4=-3175/1005, 4-5=-3454/1074, 5-6=-3728/1014, 6-7=-3844/1011, 7-8=0/16 BOT CHORD 1-12=-1191/3632,11-12=-913/3277,10-11=-913/3277,9-10=-803/2969,7-9=-941/3664 WEBS 2-12=-515/280, 3-12=-31/438, 4.12=-251/125, 4-10=-1133/464, 5-10=-458/1292, 5-9=-2541769, 6-9=-299/179 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 38B lb uplift at joint 1 and 421 lb uplift at joint 7. LOAD CASE(S) Standard I,- Job- Truss Truss Type X07-459 C1 JACK Universal Forest Product, Inc.359, Vero Beach, Fl. 32967, James Shoat -1-0-0 — ---- -- 1-0-0 3.00 F1-2 2 T1 5 _J__�lJob ReLe �nce optional) 7,030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:1'48 2008 Pa a 1 1-6-0 B1 4 1-6-0 4x4 = 1-6-0 LOADING(psf) SPACING 2-0-0 CS1 DEFIL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.08 Vert(LL) -0.00 2 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) -0.00 2 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Hbrz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004tTP12002 (Matrix) Weight: 6 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-6-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (IbIsize) 2=171/0-7-8, 4=14/Mechanical, 3=20/Mechanical Max Horz2=34(LC 3) Max Upl==-1 1 5(LC 3). 3=-12(LC 4) Max Grav2=171 (LC 1), 4=28(LC 2). 3=20(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0116,2-3=-21/3 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf,* Category 11; Exp 5; enclosed; MWFRS (low-rise); cantilever left and right exposed Lumber DOL=1.60 plate grip I)OL=1.60 2) *Thlitruss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 115 lb uplift at Joint 2 and 12 lb uplift at joint 3. LOAD CASE(S) Standard j-- — — — 1-5-4 — — -- — -- - — I 4x4 = 1-5-4 Fiate offset.. txn 5,6.5-n.n-n-1i --- ---------------------..__—_._---------•----- - ------ LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) -0.00 1 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) -0.00 1 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC20041TP12002 (Matrix) Weight: 4 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-5-4 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=62/0-6-12, 3=14/Mechanical, 2=48/Mechanical Max Horz1=18(LC 3) Max Upli tl=-18(LC 3), 2=-26(LC 3) Max Grav1=62(LC 1), 3=27(LC 2), 2=48(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-11/11 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7.02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) 'This truss' has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 18 lb uplift at joint 1 and 28 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Type a Ply MORNINGSUE MASTERS PHASE 11 X07-459 JACK 5 Job Reference op lonal) Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967, James Shoal 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10; 15:48 2008 Page 1 .1-0-0 3-0-0 1-0-0 3-0-0 Scale = 1: 9 3.00 F-12- 2 T1 Bi 4 04 = 3-0-0 3-0-0 LOADING(psf) TCLL 20.0 SPACING 2-0-0 Plates Increase 1.25 CS1 DEFIL in TC 0.12 Vert(LL) -0,00 (loc) I/dell Ud 2-4 >999 360 PLATES GRIP MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Verl(TQ -0,01 24 >999 180 1 BCLL 10.0 Rep Stress Incr YES W13 0.00 Horz(TL) -0.00 3 n1a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 11 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (italsize) 3=68/Mechanical, 2=237/0-7-8, 4=26/Mechanical Max Horz 2=51 (LC 3) Max Upiift3=-30(LC 3), 2=-141 (LC 3) Max Grav3=68(LC 1), 2=237(LC 1), 4=53(LC 2) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16,2-3=-32114 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf,, Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent With any other live loads. 3) Refer to girder(s) for truss to truss connections, 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 30 lb uplift at joint 3 and 141 lb uplift at joint 2. LOAD CASE(S) Standard 29 10:1548 2008 Scale = 1 —-- 2-11-4 ----- — — — 2-11-4 LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.11 Vert(LL) -0.00 1-3 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.06 Vert(TL) -0.01 1-3 >999 180 BCLL 10.0 Rep Stress Incr YES WS 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2004lrP12002 (Matrix) _ Weight: 9 lb LUMBER BRACING _ __-- TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/slze) 1 = 117/0-6-12, 2=91[Mechanical, 3=26/Mechanical Max Horz1=34(LC 3) Max Upliftl=-34(LC 3), 2=-52(LC 3) Max Gravl=117(LC 1), 2=91(LC 1), 3=52(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-20120 SOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3,Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 34 lb uplift at Joint 1 and 52 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply MORNINGSIDE MASTERS PHASE 11 X07-459 JACK 4 - Job Reference (opLiona!)_ —Universal Forest Product, Inc. E359, Vero Beach, Fl. 32§67, —James-Slioaf 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:48 2008 Page 1 Truss 5-0-0 3 Scale = 16. 3.00 F1_2 T1 2 B I 44 5-0-0 5-0-0 LOADING(psf SPACING 2-0-0 CS1 DEFIL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.28 Vert(LL) -0.02 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 SC 0.20 Vert(TQ -0.06 2-4 >924 180 BCLI_ 10.0 Rep Stress I ncr YES WS 0.00 'Horz(TL) -0.00 3 n/a n1a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 17 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=148/Mechanical,2=316/0-7-8,4=46/MechanicaI Max Horz2=73(LC 3) Max LIpIift3=-79(LC 3), 2=-1 59(LC 3) Max Grav3=148(LC 1), 2=316(LC 1), 4=93(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16,2-3=416/30 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf,, BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed Lumber QOL=1 .60 plate grip DOL=1.60 2) *This truss has been designed for a 10,0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 3 and 159 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Truss Type y ply MORNINGSIDE MASTERS PHASE 11 X07-459 CJ1U JACK 8 1 Job Reference jqRLqn_aD._ Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967. James Shoaf 7.030 a Jan 3 2008 MiTek Industries, Inc, Tue Jan 29 10:15:48 2008 Page 1 1-0-0 1-0-0 1-0-0 Scale = 1:4.7 2 5-00 F1-2 X 8 T1 1 4x4 4 1-0-0 LOADING(ps� SPACING 2-0-0 CS1 DEFL In (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.08 Vert(LL) -0.00 2 >999 350 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.01 Vert(TL) -0.00 2 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC20041TPI2002 (Matrix) Weight: 5 lb LUMBER BRACING - TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=162/0-3-8, 4=10/Mecharilcal, 3=-9/Mechanical Max Horz2=49(LC 5) Max Uplift2=-122(LC 5), 3=-9(LC 1) Max Grav2=162(LC 1), 4=19(LC 2), 3=22(LC 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27,2-3=-32/9 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Dpsf; Category 11; Exp B: enclosed; MWFRS (low-rise); cantilever left and right exposed Lumber DOL=1 .60 plate grip DOL=1.60 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 122 lb uplift at joint 2 and 9 Ito uplift at joint 3. LOAD CASE(S) Standard Job Truss X07459 JACK Type 8 City Ply 1 erence.(MORNINGSIDE MASTE pliong.1)RS PHASE 11 J Job --T -- — - -Universal —Forest ProcFt;j. Inc. E359, Vero Beach, Fl. 32967, James Shoal 7.030 a Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:49 2008 Page 1 1-0-0 3-0-0 Scale = 1:7.9 6.00 F-12 TI 2 2 B 1 4 ----- ------ lx4� LOADING(psf) SPACING 2-0-0 CS1 DIEFL in (foc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.10 Vert(LL) -0.00 2-4 199 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) -0.01 2-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n1a n/a BCDL 10.0 Code FBC2004rrPI2002 (Matrix) L Weight: 11 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=80/Mechanical, 2=22810-3-8,4=28/Mechanical Max Horz2=85(LC 5) Max Uplift3=-45(LC 5), 2=-123(LC 5) Max Grav3=80(LC 1), 2=228(LC 1), 4=56(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27,2-3=-48/25 BOT CHORD 2-4=010 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf,, BCDL=3.Opsf, Category 11; Exp B: enclosed; MWFRS (low-rise); cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 45 lb uplift at joint 3 and 123 lb uplift at joint 2. LOAD CASE(S) Standard JACK 8 1 1 Job Reference oLtional) James Shoat — 7,030 s Jan 3 2008 MITek Industries, Inc. -i-n-rn c n.n Scale = 1:11. 4x4 -= 5 0-0 5-0-0 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.32 Vert(LL) -0.03 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.22 Vert(TL) -0.07 2-4 >831 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(fL) -0.00 3 nla n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 17 Ito LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=157/Mechanical, 2=31010.3-8, 4=48/Mechanical Max Horz2=122(LC 5) Max Uplift3=-97(LC 5), 2=-138(LC 5) -Max Grav3=157(LC 1), 2=310(LC 1), 4=96(LC 2) FORCES (lb) - Maximum Compression/Maxlmum Tension TOP CHORD 1-2=0/27, 2-3=-71/49 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.6C 2)'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 97 lb uplift at joint 3 and 136 lb uplift at joint 2. LOAD CASE(S) Standard • X07-459 E5 —U—niveislill ­Fores-t ­ProduEt, Inc. E359, Vero Beach, Fl. 32967, -1-0-0 1-0-0 2 Qty MU NIN(361LIL: MAbTl-'Kb PMA51 It 2 1 Reference Co 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:49 2008 Page 4--Q—O 4-0-0 Scalo: 1. 3.00 [T2 TI BI 4 44 4-0-0 4-0-0 LOADING(ps,f) SPACING 2-0-0 CS1 DEFIL In (loc) I/def! Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.16 Vert(LL) -0.01 2-4 >999 360 MT20 244/190 TCDL - 15.0 Lumber Increase 1.25 BC 0.12 Vert(TL) -0M 2-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n1a n1a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 14 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc, purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=109IMechanical,2=275/0-7-8,4=36/MechanicaI Max Horz2=62(LC 3) Max Uplift3=-56(LC 3), 2=-149(LC 3) Max Grav3=109(LC 1), 2=275(LC 1), 4=73(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16,2-3=-39/23 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf,, BCDL=3.Opsf,, Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of Withstanding 66 lb uplift at joint 3 and 149 lb uplift at joint 2. LOAD CASE(S) Standard Job - Truss Truss Type ---Inc:� X07-459 E7 5 ,Vero Beach, - FI. 32967, James Shoal 1-0-0 2 4x4 = 3.00j12 T1 6 1 Reference (optional)__ 7.030 s Jan 3 2008 MiTek Inc 6-0-0 6-0-0 B1 is Jan 29 10:15:49 2008 Page 4 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates increase 1.25 TC 0.45 Vert(LL) -0.05 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.30 Vert(TL) -0.13 2.4 >514 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004frP12002 (Matrix) Weight: 20 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=186/Mechanical, 2=359/0-7-8, 4=56/Mechanical Max Horz2=84(LC 3) Max Uplift3=-101(LC 3), 2=-171(LC 3) Max Grav3=186(LC 1), 2=359(LC 1). 4=113(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-54/38 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02: 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category ll; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift at joint 3 and 171 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Truss Type Oty Ply MORNINGSIDEMASTERS PHASE II X07-459 — EJ7U ---- — MONO TRUSS— --- - --- -- 18 - -� 1 Job Reference (optional)_--_ Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967, James Shoaf 7.030 s Jan—3 2008 MiTek Industries, Inc, Tue Jan 29 10 15:49 22008 Page 1 I-- -1-0-0 —1 ---- - ---- - - - ---- 6-0 0 ---- I Scale = 1:13. 5.00 12 T1 2 4 4x4 _ 6-0-0 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) Ildefl Ud PLATES GRIP - TCLL 20.0 Plates Increase 1.25 TC 0,49 Vert(LL) -0.06 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.32 Vert(TL) .0.15 2-4 >471 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n1a n/a BCDL 10.0 Code FBC2004frPI2002 (Matrix) Weight: 20lb LUMBER -- - - ---_ —BRACING ----- -- - -- ------- TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (Iblslze) 3=194/Mechanical, 2=353/0-3-8, 4=68/Mechanical Max Horz2=141(LC 5) Max Uplift3=-121(LC 5), 2=-147(LC 5) Max Grav3=194(LC 1), 2=353(LC 1), 4=116(LC 2) FORCES (lb) - Maximum Compress(on/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-68/61 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category Il; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 121 lb uplift atjoint 3 and 147 lb uplift at joint 2. LOAD CASE(S) Standard F01 FLOOR 0-1-8 HI- 2-2-0 , 2-6-0 II-2-0-6 IF--2-0-0--ii 1-8-6 I 2x3 II 2x3 11 3x5 = 2x3 11 3x6 FP = 3x6 = 1 2 3Ij 4 5 6 7 6 9 J613� ' va 5 24 23 22 21 20 19 18 3x6 = 2x3 II 2x3 II 3x6 = 3x6 FPS=_ 3x7 = us Ja❑ J 2UU6 MIIeK Inciustrles, Inc. Tue Jan 29 1U: 15:5U 2UU6 Pagel I--- -0-6 - 2-0-0- II 1-11-6- I 0--8 Scale= 1:45.1 2x3 II 2x3 II 10 11 12 13 17 16 2x3 II 14 Ill 2e J.c ii 27 15 8-2-6 9-3-14 23-0-10 - 7-0-14-----7-�-6 19-2--111 -----.16-3-4 - �-----21-0-10 2--0-1P -1p-8- -I 7-0-14 0-1-8 1-0-0 6-11-6 4-9-6 1-0-0 1-0-0 4-8-6 1-0-0 0-1-8 0-1-8 Plate Offsets (X,Y): [4:0-1-8,Edge], [5:0-1-8,Edge], [11:0-1-8,Edge], [12:0-1-8,0-0-0], [14:0-1-8Edge],116:0-1-8,Edge], [17:0-1-8.Edge], [18:0-2.4,Edge], [20:0-1 -8, Edge], [21:0-1-8,0.016], [22:0-1-8,Edge], 211-0-2-B,EdseJ,.I25:0�0-�-81..)26 0-1-8 1 _81L I27:0.1-8,0-1-Q,2�L-e_A LOADING(psf)FRep CING 2-0-0 CSI DEFL In (loc) I/defl Ud PLATES GRIP TCLL 40.0es Increase 1.00 TC 0.56 Vert(LL) -0.14 22-23 >999 480 MT20 244/190 TCDL 10.0ber Increase 1.00 BC 0.73 Vert(TL) -0.20 22-23 >959 240 BCLL 0.0Stress Incr YES WB0.31 Horz(TL) 0.04 15 n/a n/a BCDL 5.0e FBC20047rP12002 (Matrix) Weight: 145 lb LUMBER -- -- -- -- --- ---- -- - - --- BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-G-0 oc pudins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 4 X 2 SYP No.2 6-0.0 oc bracing: 17-18. REACTIONS (lb/size) 24=815/0-7-4, 15=531/0-6-12, 18=1679/0-8-0 Max Grav24=846(LC 7), 15=583(LC 4), 18=1679(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 24-25=-87/0, 25-26=-87/0, 1-26=-87/0, 15.27=-103/0, 27-28=103/0, 14-28=-103/0, 1-2=0/0, 2-3=-1853/0, 3-4=-1853/0, 4-5=-208310, 5-6=-1771/0, 6-7=-1771/0, 7-8=-1771/0, 8-9=0/859, 9-10=0/859, 10-11=-985/0, 11-12=-985/0, 12-13=-985/0, 13-14=0/0 BOT CHORD 23-24=0/1070, 22-23=0/2083, 21-22=0/2083, 20-21=0/2083,19-20=0/949, 18-19=0/949, 17-18=-215/595, 16-17=019B5, 15-16=01761 WEBS 4-22=-110/49, 5-21=-32/142, 11-17=-318/0, 12-16=-147/46, 9-18=-28710, 2-24=-130110, 2-23=0/913, 3-23=-289/0, 4-23=-382130, 13-15=-889/0, 13-16=-611282, 10-18=-112910, 10-17=01658, 8-18=-1595/0, 8-20=0/1049, 6-20=-239132, 5-20=-628/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard i VA- • JOD X07-459 Universal Forest Product, I r 0-1-8 H 2x3 11 3x5 = 1 2 -TT- 68 5 �?M 24 Truss Truss Type Oty Ply MORNINGSIDE MASTERS PHASE II F02 FLOOR 2 1 __ Job Reference (optional) _ !359, Vero Beach, FI. 32967. James Shoaf 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:50 22008 Page 1 [-� L �� 2"� �' 2i 1 6 1-7"6.����..-i�-11-6-i 0-1I1.-8 Scaft� = 1:45.'. 2x3 II 2x3 II 3x6 FP= 3x6 = 2x3 II 2x3 II 3 T1 4 5 6] 7 8 9 10 T7 11 12 13 2x3 11 14 al 28 �pr 27 15 1 WN M 23 22 21 20 19 18 17 16 3x6 = 2x3 II 2x3 II 3x7 = 3x6 FP= 3x7 = 8-2-6 9-3-14 23-0-10 �- 7-0-14 _7-�-6 .19-2-61 16-8=421-0-10 -_ 2=0.1�-2^ 27-10_8.- 1 7-0-14 0-1-8 1-0-0 7-4-6 4-4-6 1-0-0 1-0-0 4-8-6 1-0-0 0-1-8 0-1-8 Plate Offsets (X,Y): [4:0-1-8,Edge], (5:0-1-8,Edge], [8:0-2-12,Edge], [11:0-1-8,Edge], [12:0-1-8,0.0-0], [14:0.1-8,Edge], (16:0-1-8,Edge), [17:0-1-8,Edge], [18:0.2 4,Edge], [20:0-2-4,Edge], (21:2-1-8,0.0-0], ___[22:0-1-8 Edge], [25_0-1-8,0-1-81, [26:0-1J_0-1-j,.2[ 7:0-1-8,0-1_8],_[28:0-1-8,0_1-� LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.66 Vert(LL) -0.14 22-23 >999 480 MT20 244/190 TCDL 10.0 Lumber increase 1.00 SC 0.72 Vert(TL) -0.22 15-16 >607 240 BCLL 0.0 Rep Stress Incr YES WB 0.32 Horz(TL) 0.05 15 n/a n/a BCDL 5.0 Code FBC20041TPI2002 (Matrix) Weight: 145 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing, Except: WEBS 4 X 2 SYP No.2 6-0-0 oc bracing: 17-18,16-17. REACTIONS (lb/size) 24=841/0-6-12, 15=506/0-6-12, 18=1678/0-5-8 Max Grav24=865(LC 7), 15=568(LC 3), 18=1678(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 24-25=-102/0, 25-26=-102/0, 1-26=-102/0, 15-27=-10210, 27-28=-102/0, 14-28=-102/0, 1-2=0/0, 2-3=-1975/0, 3-4=-1975/0, 4-5=-2183/0, 5-6=-1820/0, 6-7=-1820/0, 7-8=-1820/0, 8-9=0/853, 9-10=0/853, 10-11=-929/24, 11-12=-929/24, 12-13=-929/24, 13-14=0/0 BOT CHORD 23-24=011234, 22-23=0/2183, 21-22=0/2183, 20-21=0/2183,19-20=0/943, 18-19=01943, 17-18=-2671608, 16-17=-24/929, 15-16=07735 WEBS 4-22=-109171, 5-21=-46/118, 11-17=-337/0, 12-16=-130/67, 9-18=-294/0, 2-24=-1441/0, 2-23=0/864, 3.23=-264/6, 4-23=-413/42, 13-15=-858/0, 13-16=-104/244, 10-18=-1086/0, 10-17=0/618, 8-1 8=-1 632/0, B-20=0/1102, 6-20=-269/5, 5-20=-630/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise Indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job Truss X07-459 F03 Universal Forest Product, Inc. E359, V*— 0-1-8 H I— 2-6-0 — 2x3 11 3x4 = 3x4 = 1 1 3x4 = 3x5 2 Truss Type Oty Ply MORNINGSIDE MASTERS PHASE It FLOOR 8 1 _ JobRef(jrencejoptlonal) - Ies Shoal 7,030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:51 2008 Page 1 1-8-6 2-0-0 1-5-2 Scale = 1:26.5 2x3 II 3x4 = 3x4 = 2x3 II 3x5 3x4 I[ 3 4 5 6 7 8 3x6 = 2x3 It 2x3 II 3x6 = 3x5 9-3-14 7-0-14 7 2 6 8 2� 9-2 6 _ _— _ 16-1-8 7-0-14 0-1-8 1-0-0 1-0-0 0-1-8 6-9-10 Plate Offsets X�: [4:0-1-8,Edge1 [5:0-1-_§,Edge], 9[ 0-2-O,Edgel, [11:0 1-8.0-0-01, 12:0-1-8,Edga]_[15.0-1-8,0-1-8], [16_0-1 8 0, -1-81 _ LOADING(psf) SPACING 2-0-0 CSI DEFL in (Icc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.48 Vert(LL) -0.13 12-13 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.69 Vert(TL) -0.16 12-13 >999 240 BCLL 0.0 Rep Stress Incr YES WS 0.29 Horz(TL) 0.04 9 n/a n/a BCDL 5.0 Code FBC2004ITP12002 (Matrix) Weight: 87 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except and verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (Ib/size) 9=870/Mechanical, 14=870/0-6-12 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 14-15=-102/0, 15-16=-102/0, 1-16=-102/0, 8-9=-104/0,1-2=0/0, 2-3=-1990/0, 3-4=-1990/0, 4-5=-2204/0, 5-6=-1997/0, 6-7=-1997/0, 7-8=0/0 BOT CHORD 13-14=0/1242, 12-13=012204, 11-12=0/2204, 10-11=012204, 9-10=0/1268 WEBS 4-12=-100/97, 5-11=-98/115, 2-14=-1450/0, 2-13=0/873, 3-13=-259/20, 4.13=-508/17, 7-9=-1470/0, 7-10=0/852, 6.10=-243/42, 5-10=-523/25 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard X07A59 F04 FLOOR Universal Forest Product, Inc. E359 Vero Beach, Fl. 32967, James Shoaf 0-1-8 1-11-6 2x3 11 3x4 = 3x4 = 1 12 11 3x4 = 2x3 11 2 3 1_IJob Reference op 7.030 s Jan 3 2008 h 2-0-0 - ----i )-----8"� ---... i 2x3 II 3x4 4 5 Jan 29 10:15:59 2008 Psge Scale = 1:1� 3x4 II 6 3x4 = 3x5 = 4-8-6 4- -14 5-9-14 6-9-14 6-1 -6 11-4-8 4-8-6 0-1-8 1-0-0 1-0-0 0-1-8 4-5-2 Plate Offsets (X,Y): 3:0-1.8,Edge], [4:0-1-8,0-0-0], [7:0-2-O,Edge], 8[ 0-1-8,Edge], [9:0-1=8 Edge], [11:0.1-8 0. 1 81, f12:0-1 8,0-1 6]____ ---- —� — --- — LOADINGSPACING 2-0-0 CSI DEFL In (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.41 Vert(LL) -0.09 9-10 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.39 Vert(TL) -0.15 9-10 >865 240 BCLL 0.0 Rep Stress Incr YES WB 0.18 Horz(TL) 0.02 7 n/a nJa BCDL 5.0 Code FBC2004JTP12002 (Matrix) Weight: 60 lb LUMBER BRACING —_-- --- —— -- ------ ------ TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD a X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 7=608/Mechanical, 10=608/0-6-12 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 10-11=-104/0, 11-12=-104/0, 1-12=-104/0, 6-7=-11010, 1-2=010, 2-3=-1077/0, 3-4=-1077/0, 4-5=-1077/0, 5.6=0/0 BOT CHORD 9-10=0/803, 8-9=0/1077, 7-8=0/819 WEBS 3-9=-202/0, 4-8=-227/0, 2-10=-93710, 2-9=0/439, 5-7=-950/0, 5-8=0/448 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 10 9 3x4 II 3x4 = 1 2x3 11 2 3 3x4 = .006 Scale = 1:10. 4 3x4 11 3x4 = 3x5 == 6-4-12 6-4-12 — LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) Ildefl Ud PLATES GRIP TCLL 40.0 Plates increase 1,00 TC 0.33 Vert(LL) -0.02 5-6 Xii 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.21 Vert(TL) -0.03 5-6 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.08 Horz(TL) 0.00 5 n/a n/a BCDL 5.0 Code FBC2004lrP12002 (Matrix) Weight: 39 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc pudins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 5=335/Mechanlcal, 8=335/0-6-12 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 8-9=-115/0, 9-10=-115/0, 1-10=-115/0, 4-5=-118/0, 1-2=0/0, 2-3=-367/0, 3-4=0/0 BOT CHORD 7-8=0/367, 6-7=0/367, 5-6=0/367 WEBS 2-8=-426/0, 3-5=42310, 2-7=-50/94, 3-6=-55/88 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10.0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard —___..--___—.-- Truss Job Truss Type -TF __ ty--fffY MO X07-459 FLOOR L. 1 _----- Job Retereijce (9ptional) Universal Fo Forest Product, Inc. E359, Vero Beach, Fl. 7, James Shoal —...� 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:512008 Page 1 2-0-12 Scale= 1: 12.4 4x4l 4x4 11 4x4 11 1 44 11 2 3 4x4 4 ---W3 C N2 1 W4 W3 4x4 44 =4x6 zz 7-8-4 7-8-4 Plate gfhjets (X,Y)., 12LO Ed .0-1-8 Edgel,[q. 0-1 -81. -8,Ed E_gje 17 LOADING(psf) SPACING 2-0-0 CS, TCLL 40.0 Plates Increase 1.00 TC 0.29 DEFL in (l.r) Idefi Ud PLATES GRIP Vert(LL) -0.01 6 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.20 Vert(TL) -0.07 5-6 >999 240 BOLL 0.0 Rep Stress Incr YES WB 0.11 Horz(TL) 0.01 5 n/a n/a BCDL 5.0 Code FBC20041TPI2002 (Matrix) Weight: 44 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. SOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 5=406/Mechanical, 7=406/0-6-12 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 7-8=-10910,8-9=-10910,1-9=-109/0.4-5=-109/0,1-2=0/0,2-3=-494/0,3-4=0/0 BOT CHORD 6-7=01494,5-6=0/471 WEBS 2-7=-573/0, 3-5=-546/0, 2-6=0/31, 3-6=0129 NOTES 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard X07-459 F07 FLOOR 1 1 30 s Jan 2008 honk_-._ Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf � 7,030 s Jan 3 2008 MiTek Industries, Inc, Tue Jan 29 10:15:52 2008 Page 1 0-H-8 Scale = 1 30 = _ 3x4 = 3x4 = 3x4 = 3x4 =_ 3x4 = 3x6 FP= 3x4 = 3x4 = 3x4 -= 1 2 3 4 5 Tj 6 7 8 9 10 11 12 13 14 15 16 18 19 20 21 22 23 8B 2 1 1 1 1 1 1 3 1 1 q31 W 1 1 - 1 1 _ 1 1- 1 - 1 - 1 W 1 50 L 49 17 UN 46 45 44 43 42 I" imam 41 40 39 38 37 36 35 34 33 32 MEEN IMMI 31 30 29 28 27 26 25 24 3x4 = 3x4 = 3x6 FP= 3x4 -= 3x5 =_ 27-10-8 LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.41 Vert(LL) n/a - n/a 999 MT20 2441190 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a n/a 999 BCLL 0.0 Rep Stress Inor NO WB 0.07 Horz(TL) -0.00 24 n/a n/a BCDL 5.0 Code FBC2004/TPI2002 (Matrix) Weight: 145 lb LUMBERBRACING --------------------...- ---• TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 46=220/27-10-8, 24=209/27-10-8, 45=581/27-10-8, 44=484127-10-8, 43=512/27-10-8, 42=505127-10-8, 41=507/27-10-B, 40=508/27-10.8, 39=501/27-10-8, 38=455/27-10-8, 37=474/27-10-8, 25=565/27-10-8, 26=441/27-10-8, 27=522/27-10-8, 28=503/27-10-6, 29=508/27-10-8, 30=506/27.10-8, 31=507/27-10-8, 32=507127-10-6, 33=369/27-10-8, 34=737/27-10-8,36=328/27-10-8 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 46-47=-215/0, 47-48=-21510, 1-48=-215/0, 24-49=-203/0, 49-50=-203/0, 23-50=-203/0, 1-2=-810, 2-3=-8/0,,3.4=-810, 4-5=-8/0, 5-6=-810, 6-7=-8/0, 7-8=-8/0, 8.9=-8/0, 9-10=0155, 10-11=0/55, 11-12=0/55, 12-13=0/122, 13-14=0/122, 14-15=0/6, 15-16=0/6, 16-17=0/6, 17-18=0/6, 18-19=0/6, 19-20=0/6, 20-21=0/6, 21-22=0/6, 22-23=016 BOT CHORD 45-46=0/0, 44-45=0/8, 43-14=0/8, 42-43=018, 41-42=0/8, 4041=0/8, 39-40=018, 38-39=0/8, 37-38=018, 36-37=-55/0, 35-36=-5510, 34-35=-55/0, 33-34=-6/0, 32-33=-6/0, 31-32=-6/0, 30-31=-6/( 29-30=-6/0, 28-29=-6/0, 27-28=-6/0, 26-27=-6/0, 25-26=-6/0, 24-25=0/0 WEBS 245=-575/0, 3.44=47210, 4-43=499/0, 5-42=49210, 641=49310, 7.40=495/0, 8-39=-48810, 9-38=441/0, 11-37=-391/0, 22-25=-543/0, 21-26=-430/0, 20-27=-508/0, 19-28=-490/0, 18-29=-494/0, 17-30=-493/0, 16-31=-494/0, 15-32=-493/0, 14-33=-356/0, 13-34=-510/0, 1-45=0112, 23-25=-9/0, 9-37=-96/0, 14-34=-177/0, 12-36=-318/0, 12-34=-103/0 NOTES 1) All plates are 2x3 MT20 unless otherwise Indicated. 2) Gable requires continuous bottom chord bearing. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-D oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (6). LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert:24-46=-10, 1-23=-370(F=-270) Job Tru X07-059 - FGts ---- FLOORype--------_---------"-.-�Ty -- Ply-- �ORNINGSIDE pASTERS PHASE II '--------"--- ""-"-- " 3 Job Reference o tonal)_ Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf 7.030 s Jan 3 2008 MITek Industries, Inc. Tue Jan 29 10:15:52 2008 Page 1 2-0 6 2-4-2 Scale = 1:27.3 5x6 - 2x3 II 3x4 = 3x7 = 5x16 1 5x16 - 2 3x7 = 3 4 5 6 7 ---— -------------------- tT 2 - 4 �yLS 3 Ws/� 3- --- - 3 ---- W 1 -- - 13 12 11 10 3x7 -- 9 5x7 = 8 46 = 5x7 - 3x7 3-11-5 S:iB�=---------- ----i .- . 3-11-5 4-1-54x6 — ---- 17-0-4 - ----- -- I 17-0-4 Plate OffsetsLX Y)_[1 0 7-12,_ _ 0-2-8], 2:0-1-12,0_11L:0-3-0,0,3:4]"[6:0-1-12 0.1-81[7:0-7-12,0-2_8]_[9_0-1-12,0-2-8L[10:0-1,12,_0-1.8],111 :0-4 0 0 4-121,112.0_1.12,0_1�_[13.0_1-12,0.2 8j_ LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) Well Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.75 Vert(LL) -0.31 11 >624 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.80 Vert(TL) -0.48 11 >400 240 BCLL 0.0 Rep Stress Incr NO WB 0.99 Horz(TL) 0.05 8 n/a n/a BCDL 5.0 Code FBC20G4/TPI2002 (Matrix) Weight: 307 lb LUMBER BRACING _._..-- --.--------- -------- TOP CHORD 2 X 4 SYP No.1 TOP CHORD Structural wood sheathing directly applied or 4-2.2 oc purlins. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. WEBS 2 X 4 SYP No.2 'Except* W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W1 2 X 6 SYP SS REACTIONS (lb/size) 8=6836/0-3-8, 14=683610-8-0 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-11517/0, 2-3=-1837610, 3-1=-20586/0, 4-5=-20586/0, 5-6=-18405/0, 6-7=-11515/0 BOT CHORD 13-14=-0/0, 12-13=0/11517, 11-12=0/18504, 10-11=0/18405, 9-10=0/11515, 8-9=0/0 WEBS 1-14=-5813/0, 7-8=-5811/0, 4-11=-187/0, 2-13=-3604/0, 3-12=-1324/0, 5-10=-1315/0, 6.9=-3615/0, 2-12=017639, 3-11=0/2316, 5.11=0/2404, 6-10=0/7674, 7-9=0/12823, 1-13=0/12825 NOTES 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0.4-0 oc. Webs connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except If noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise Indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 8-14=-749(F=-739), 1-7=-100 I Job --Tms—sType--,- �ORNINGSIDE b Reference i2nal) X07-459 FG2 FLOOR 'ffr'oduct Universal Forest TF5 Inc E359, Ve-F-B— James Sheaf Inc. E359, Vero o leach, Fl. 32667. 7.030 s Jan 3 2008 MiTek Industries, Inc, Tue Jan 29 10:15:53 2008 Page I 2-8-14 10-? 2-11 -12 2-4-8 Scale = 1:45.4 16-8-4 3x6 3x7 = 5x5 = 3x7 ----3x" 2 3 2425 5 6. 7 8 9 10 11 T-1 1 2 4 5 7 W W2--- 1 B 23 22 21 20 19 18 17 16 16 14 13 12 2x5 11 3x4 = 4x6 5x8 = 3x4 == 2x5 11 27-7-8 16-8-4 16-8-4 11-2-4 Plate Offsets (X,Y): [3:0-2-4, -1-8], [4:0-2-4,0-1-8], [5:0-3-0,0-1-8], [6:0-2-8,0-3-0], [7:0-3-0.0-1-8]. [8:0-2-4.0-1-8], [9:0-2-4,0-1-8]. (13:0-1-12,0-1-8], [14:0-2-4,0-1-6], 115:0-2-4,0-1 -8], [16:0-2-4,0-1-8]. [17:0-4-0 0-2-4,_[190-2-4,Q:j�-8� 0-2-40-1-8 :0-2-4.0-1-ffl -9-1 -0-118] LOADING(psf) SPACING 2-0-0 CSI D EFIL In (loc) 1/defl Ud TCLL 40.0 Plates Increase 1.00 TC 0.39 Vert(LL) -0.07 20 >999 480 PLATES GRIP MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.21 Vert(TL) -0.11 20 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.41 Horz(TQ 0.01 12 n/a n/a BCDL 5.0 Code FBC20D41TPI2002 (Matrix) Weight: 328 lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHbRD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2 X 4 SYP No.2 *Except' W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W1 2 X 6 SYP SS W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W1 2 X 6 SYP SS REACTIONS (fb/size) 23=1032/0-6-12,16=4423/0-5-8,12r484/0-6-12 Max Grav23=1 068(LC 2), 16=4423(LC 1). 12=695(LC 3) 1 - FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-2090/0,2-3=-3290/0,34=-3291/0,4-24=-2496/0,24-25=-2496/0,5-25=-2496/0,5-6=-421/709,6-7=-4211709,7-8=013049,8-9=-1476f7l1,9-10=-1664/260,10-11=-1238/36 BOT CHORD 22-23=0/0,21-22=012090,20-21=0/3290,19-20=0/3291,18-19=0/2496,17-18=0/2496,16-17=-3049/0,15-16=-711/1476,14-15=-260/1664,13-14=-36/1238,12-13=0/0 WEBS 3-21=-1751160,9-14=0/390.5-19=0/530, 7-16=-2663/0, 8-15=0/763, 4-20=0/310, 2-22=-85710,10-13=-539/25, 2-21=0/1299,3-20=-4271113, 4-19=-1255/0, 10-14=-242/460, 9-15=-717/0, 8-16=-349410,6-17=-80610, 5-17=-242110, 7-17=0/3557,1-23=-102610,1-22=0/2277,11-12=-65510,11-13=-39/1349 NOTES 1) 2-ply truss to be connected together with 10d (0.131"0") nails as follows: Top chords connected as follows: 2 X 4 -1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc, 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (8), unless otherwise Indicated. 3) Unbalanced floor live loads have been considered for this design. 4) All plates are 3x5 MT20 unless otherwise indicated. 5) The Fabrication Tolerance at joint 18 = 20% 6) Recommend 2x6 strongbarks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) CAUTION, Do not erect truss backwards. '8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 406 lb down at 6-5-8, and 757 lb�.wn at 20-1-8 on bottom chord. The design/selection of such connection device(s) Is the responsibility of others. LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 12-23=-1 0, 1-5=-1 00, 5-8=-300(F=-200). 8-11 =-1 00 Concentrated Loads (lb) Vert: 21=-406(F) 15=-757(F) Jot) Truss Truss Type Qty Ply MORNINGSIDE MASTERS PHASE 11 X07-459 FG3 FLOOR 1 Job Reference -f(op itionA u _ ____ U-nIversalForest Product, Inc. E359, Vero Beach, Fl. 32967, James Shoaf 7.030 s Jan 3 2008 MiTek Industries, Inc, Tue Jan 29 10:15:53 2008 Page 1 1 46 = 2-7-8 2 4x4 11 Scale = 1:8.2 T1 W1 W3 BI 4x4 11 04 X X 5 3 3-4-8 3-4-8 Plate Offsets(X, )L.12:1E0q,P-3-81 LOADING(psf) SPACING 2-0-0 CS1 DE FL In (loc) I/defl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.29 Vert(LL) -0.01 3-4 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.16 Vert(TL) -0.01 3-4 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2004ITP12002 (Matrix) Weight: 21 Ito LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-8 oc, purlins, except end verticals. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid calling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 'Except* W1 2 X 6 SYP SS REACTIONS (lb/size) 4=320/Mechanical, 3=334/Mechan(cal FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-4=-150/0, 2-3=-150/0, 1-2=0/0 BOT CHORD 4-5=0/0, 3-5=-0/0 WEBS 1-3=0/0 NOTES 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) Hanger(s) or other connection device(s) shalt be provided sufficient to support concentrated load(s) 325 lb down at, 1-9-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 4) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (5). LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 3-4=-1 0, 1 -2=-1 00 Concentrated Loads (lb) Vert: 5=-325(B) • X07-459 FG4NS Truss FLOOR ype — 1 Joob ReferenceE etlonaORS PHASE II 'o Beach, FI.32967, James Shoaf -- 7.030 s Jan 3 2008 MITek Industries, Inc 1 46 = 2-7-g 2 4x4 II Scale = f ----- — '-"-o 3-4-8 Plate Offsets (X Yj_LEdgeA3 ]— --- _----------------------- ----------------- LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) Udefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.29 Vert(LL) -0.01 3-4 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.19 Vert(TL) -0.01 3-4 >999 240 BCLL 0.0 Rep Stress Incr NO WB O.00 Horz(TL) -0.00 3 We n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 21 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-8 cc pudins, except end verticals. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10.0.0 cc bracing. WEBS 2 X 4 SYP No.2 *Except' W12X6SYP SS REACTIONS (lb/size) 4=35510-1-8, 3=371/Mechanical FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-4=-150/0, 2-3=-150/0, 1-2=0/0 BOT CHORD 4-5=-0/0, 3-5=-0/0 WEBS 1-3=0/0 NOTES 1) Refer to girder(s) for truss to truss connections. 2) Provide mechanical connection (by others) of truss to bearing plate atjoint(s) 4. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 396 lb down at 1-9-8 on bottom chord. The design/selection of such connection device(s) Is the responsibility of others. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 3-4=-10, 1-2=-100 Concentrated Loads (lb) Vert: 5=-396(F) • X07-459 FG5 Universal Forest Product, Inc. E359, 44 11 4x4 = 1 2 25 6- ROOF TRUSS 4i2AA 1� 3� _-�__I__2_1 Job 7.030 s Scale = 1 8x10 =- 5x8 = 4x4 = 8x8 -- 4x4 = 4x4 = 4x4 II 3 4 27 5 6 7 8 9 28 10 11 12 13 23 26 22 21 10x16 MT18H= 5x8 = 6-10-3 6-1 -8 I----- -- --r -- 6-10-3 0-0-5 19 18 17 29 16 4x4 = 4x4 =. 8x8 = 44 20-9-0 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES ' GRIP TCLL 40.0 Plates Increase 1.60 TC 0.95 Vert(LL) -0.29 17-18 >857 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.74 Vert(TL) -0.45 17-18 >549 240 MT18H 244/190 BCLL 10.0 Rep Stress Incr NO WB 0.68 Horz(TL) 0.04 14 n/a n/a BCDL — 5.0 — Code FBC2004/TP12002 — — — (Matrix) f Wind(ILL) 0.16 17-18 >999 360 Weight: 360 lb ------...___...------- LUMBER BRACING TOP CHORD 2 X 6 SYP SS TOP CHORD Structural wood sheathing directly applied or 4-6-4 oc purlins, except end verticals. BOT CHORD 2 X 8 SYP SS BOT CHORD Rigid ceiling directly applied or 4-4-1 oc bracing. WEBS 2 X 4 SYP No.2 "Except' W1 2X6SYP SS, W1 2X6SYP SS, W42X6SYP SS REACTIONS (lb/size) 14=3944/0-5-4, 25=-1334/0-5-4, 22=10364/0-3-8 Max Upl'ift14=-1091(LC 3), 25=-1334(LC 1), 22=-2867(LC 3) Max Gravl4=3944(LC 1), 25=369(LC 3), 22=10364(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-25=-29/13,13-14=-682/193,1-2=-81/284,2-3=-1190/4275,3-4=-2845/10266,4-27=-3721113448,5-27=-3721/13448,5-6=-976/3502,6-7=-4540/1250,7-8=-9911/2736,8-9=-12975/3584, 9-28=-13680/3778, 10-28=-1368013778, 10-11=-11535/3186,11-12=-6971/1921, 12-13=-658/179 BOT CHORD 24-25=-1827/500,23-24=-6881/1897,23-26=-13448/3721,22-26=-13448/3721,21-22=-7749/2139,20-21=-33011172, 19-20=-2164/7801,18-19=-3337/12043,17-18=-3656/13919, 17-29=-3639/13136,16-29=-3639/13136,15-16=-2724/9828,14-15=-1205/4337 NEBS 2-25=-541/1991,2-24=-3405/959,3-24=-984/3625,3-23=-4708/1318,4-22=-4555/1275,4-23=-1151/4182,12-14=-4751/1325,12-15=-996/3663,11-15=-3974/1117,11-16=-641/2374, 10-16=-2226/631, 10-17=-193/756, 9-17=-333/108, 9-18=-1314/379, 8-18=-343/1296, 8-19=-2966/836, 7-19=-796/2934, 7-20=-4536/1270, 6-20=-1280/4685, 6-21=-6501/1816, 5-21 =-1 61715907, 5-22=-7241/201 0 VOTES 1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Bottom chards connected as follows; 2 X 6 - 2 rows at 0-7-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc, 2 X 6 - 2 rows at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise Indicated. 3) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantllever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60, I) Provide adequate drainage to prevent water ponding. i) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are MT20 plates unless otherwise Indicated. All plates are 46 MT20 unless otherwise indicated. 3) Bearing at joint(s) 22 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface, i) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1091 lb uplift at joint 14, 1334 lb uplift at joint 25 and 2867 lb uplift at joint 22. 0) Uplift for first LC exceeds limits 1) CAUTION, Do not erect truss backwards. 2) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 311 lb down and 86 lb up at 6-4-0, and 345 lb down and 95 lb up at 20-0-0 on bottom chord. The design/selecfion of such connection device(s) Is the responsibility of others. .OAD CASE(S) Standard Regular. Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 14-25=-10, 1-27=-420(F=-320), 27-28=-470(F=-370), 13-28=-420(F=-320) Concentrated Loads (lb) Vert: 26=-31 1 (F) 29=-345(F) — Job Tnrss Truss Type city Ply MORNINGSIDE MASTERS PHASE II —� X07-4591 GE1 GABLE-- 1 — Jo ptib Reference (oonal Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967, James Shoaf — 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:54 2006 Page 1 6-0-12 6-0-12 6-0-12 Scale = 1:19. 3 5.00 12 4 2 T ST2 T1 S71 ST1 \ 5 1 �- - ——' - - - — 12-1-8 ---- 12-1-8 — --- - - - - _ LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.12 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.08 Vert(TL) nla - n/a 999 BCLL , 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) 0.00 5 n/a We BCDL 10.0 Code FBC2004lrP12002 (Matrix) Weight: 42 lb LUMBER BRACING -- - - -------------- TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid calling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=124112-1-8, 5=124/12-1-8, 7=80/12-1-8, 8=316/12-1-8, 6=316/12-1-8 Max Horz 1=37(LC 5) Max Upiiftl =-31 (LC 5), 5=-38(LC 6), 8=-133(LC 5), 6=•133(LC 6) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-46/45, 2-3=-44/64, 3-4=-44/60, 4-5=-46/45 BOT CHORD 1-8=0/34, 7-8=0/34, 6-7=0134, 5-6=0/34 WEBS 3-7=-76/3, 2-8=-228/137, 4-6=-228/137 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02: 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) `This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. .4) All plates are 4x4 MT20 unless otherwise Indicated. 5) Gable requires continuous bottom chord bearing. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 31 lb uplift at joint 1, 38 lb uplift atjolnt 5, 133lb uplift at joint 8 and 133 lb uplift at joint 6. LOAD CASE(S) Standard |*m |r�" |r�" Type |mw |p* |wonw�m/nsw^orE�pvxa o | |xm�o |*�u ~ | MONO mva |^ | ,| | " —____-- 1-5-0 4-4-4 4-1-9 acale:nw= LOADING(psf) SPACING 2-0-0 LUMBER BRACING TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOTCHORD 2 X 4 SYP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf,, Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed Lumber DOL=1.60 plate gnp DOL=11.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise Indicated, 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 138 lb uplift at joint 4, 182 lb uplift at joint 2 and 61 lb uplift at joint 6. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (6). LOAD CASE(S) Standard Uniform Loads (pin Trapezoidal Loads (plf) T ss Truss Type Oty Ply MORNINGSIDE MASTERS PHASE 11 X07-459 K5 JACK 1 —9n,—ve—r�.—l—F6-rest—ProdLTct,—Inc—. —Beach, Jqb� R fer. , (op .. I� E-359, Vero Fl. 3-296-7—,James Sheaf 7.030s _ Jan 3 2006 MiTek Industries, Inc. Tue Jan 29 10:15:64 2006 Page I 5-5-0 2 Scale= 1 2.12 r1_2 T 1 C� Bi 3 44 ------- — ------ 5-5-0 LOADING (psf) SPACING 2-0-0 CS1 DEFL in (too) Ildefl Ud PLATES GkIP TCLL 20.0 Plates Increase 1.25 TC 0.34 Vert(LL) -0.03 1-3 >999 360 MT20 244/190 TCOL 15.0 Lumber Increase 1.25 BC 0.23 Vert(TL) -0.07 1-3 >868 180 BCLL 1 0.0 Rep Stress Incr NO WEI 0.00 Horz(TL) -0.00 2 We n/a BCDL 10.0 Code FBC2004rrPI2002 (Matrix) Weight: 16 lb LUMBER BRACING TOPCHORD 2 X 4 SYP No.2 TOPCHORD Structural wood sheathing directly applied or 5-5-0 oc purlins. BOTCHORD 2 X 4 SYP No.2 BOTCHORD Rigid ceiling directly applied or 10-0-0 oc, bracing. REACTIONS (lb/size) 1=115/0-8-8,2=164/Mechanical,3=47/MechanicaI Max Horz 1 =32(LC 3) Max Upliftl =-33(LC 3), 2=-89(LC 3) Max Gravl=115(LC 1), 2=164(LC 1), 3=97(LC 2) FORCES (lb)- Maximum Compression/Maximum Tension TOP CHORD 1-2=-23123 BOT CHORD 1-3=010 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf,, BCDL=3.Cpsf,, Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 33 lb uplift at�jolnt 1 and 89 lb uplift at joint 2. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (6). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Trapezoidal Loads (plf) Vert: 1 =-6(F=32, B=32)-to-2=-95(F=-1 2, B=-1 2), 1 =-2(F=9, B=9)-to-3=-27(F=-4, B=-4) X07-459 K9 Job Reference (optional Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoat 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:55 2008 Page 1 f— — 1-5-0 I - -- --- -- 5-2-12 --------�--- .-.-.—_...-.-_ $ 5-1 -- -- -- — — I 1-5-0 5-2-12 3-2-5 Scale = 1:15.71 5-2-12 5-2-12 3-1-10 0-0-11 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.23 Vert(LL) -0.02 2-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.28 Vert(TL) -0.07 2-7 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.16 Horz(TL) 0.01 6 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 33 lb LUMBER BRACING-----_ ---- -- ------ TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 4=177/Mechanical, 2=386/0-10-10, 6=334/Mechanical Max Horz2=87(LC 3) Max Uplift4=-98(LC 3). 2=-192(LC 3), 6=-76(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-8=0/13, 2-6=0/13, 2-3=-908/226, 34=-35/23 BOT CHORD 2-7=-279/874, 6-7=-279/874, 5-6=010 WEBS 3-7=0/201, 3-6=-915/292 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1. 2) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections, j 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 98 lb uplift at joint 4, 192 lb uplift at joint 2 and 76 lb uplift at joint 6. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-8=-70 Trapezoidal Loads (plf) Vert: 8=O(F=35, B=35)-to-4=-147(F=-39, B=-39), 2=-2(F=9, B=9)-to-5=42(F=-11, B=-11) Job _1�ru—ss Type Ory Ply MORNINGSIDE MASTERS PHASE II X07-459 V2 VALLEY ---—----------_-_--- 1 1 Job Reference o�onal)_ Universal forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf 7.030 s Jan 3 2008 MTek Industries, Inc. Tue Jan 29 10:15.% 2-8-8 1:4 -- ---- --- — - - - 2-8-8 44 c — ---- — - LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.04 Vart(LL) n/a n/a 999 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) nla n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Harz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 6lb LUMBER - ----- --- ---BRACING -- --- ---- ---- TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-6-8 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=69/2-8-8. 2=53/2-8-8, 3=15/2-8-8 Max Horz1=17(LC 3) Max Upliftl=-21(LC 3), 2=-30(LC 3) Max Grav1=69(LC 1). 2=53(LC 1), 3=30(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-10/10 BOT CHORD 1-3=010 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.6 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Gable requires continuous bottom chord bearing. 4) Bearing at joint(s) 2 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface, 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 21 lb uplift at joint 1 and 30 lb uplift at Joint 2. LOAD CASE(S) Standard X07-459 IV2A (VALLEY I I 1 s 2-11-8 o_��_v 4x4 '--- — -- ----� LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.05 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 LjLumlereaseIncr1.25 BC 0,03 Vert(TL) n/a n/a 999 BCLL 10.0 epStressInc,YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 ode FBC2004/TPI2002 (Matrix) Weight: 7 lb LUMBER -- ---- - BRACING ----- ----- ----------- TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-11-8 oc purlins. BOTCHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=80/2-11-8, 2=62/2-11-8, 3=18/2-11-8 Max Horz 1=20(LC 3) Max Upliftl=-25(LC 3), 2=-35(LC 3) Max Gravl=80(LC 1), 2=62(LC 1), 3=35(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-12/12 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Gable requires continuous bottom chord bearing. 4) Bearing at joint(s) 2 considers parallel to grain value using ANSI/7PI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 25 lb uplift at Joint 1 and 35 lb uplift at joint 2. LOAD CASE(S) Standard X07-459 V4 VALLEY —�1 1 Job Reference o tional _ Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:55 2008 Page - - -- 4-8-8 -- -- -- --- -- — 4-8-8 2 Scale = 1:7 1 B1 3.00 12 I— — - --- — 4-8-8 ---- -- - .. 4-8-8 Plate Offsets (X Y): (3:Edge,0-3-8)— LOADING(psf) SPACING 2-0.0 CSI DEFL In (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.18 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.11 Vert(TL) n/a n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a We BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 13 lb LUMBER ---- — ----- ---- ---- - BRACING ------- - ._.. TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-8-8 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=152/4-8-8, 3=152/4-8-8 Max Horz 1=38(LC 3) Max Upliftl=-47(LC 3), 3=-56(LC 3) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-23/23, 2-3=-118/66 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60, 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise Indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 1 and 56 lb uplift at joint 3. LOAD CASE(S) Standard Job Truss Truss Type i aty Ply MORNINGSIDE MASTERS PHASE II - X07-459 V5 VALLEY — — ��1 Job Reference (optional)__ _ Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:55 2008 Page 1 2-0-12 4-1-8 2-0-12 2 2-0-12 Scale = 1:6.5 5.00 F12 B Bt 3 1-8 A --- - - 4 1 8 — ---- — -- __-- ---=_ Plate Offsets �: 2:0-2.0 Edq_e] —--"--"---- ---`-- LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/clef] L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.08 Vert(TL) n/a n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 10.0 Code FBC20041TP12002 (Matrix) Weight: 11 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-1-8 cc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS (lb/size) 1=120/4-1-8, 3=120/4-1-8 Max Horz1=9(LC 5) Max Upliftl=-34(LC 5), 3=-34(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-136/53, 2-3=-136153 SOT CHORD 1-3=-40/112 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. , 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 34 lb uplift at joint 1 and 34 lb uplift at joint 3. LOAD CASE(S) Standard Job Truss - Truss Type City ITJob PlyRNINGSIDE MASTERS PHASE II X07-459 V6 VALLEY 1 Reference (optional) Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoat 7,030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:56 2008 Page 1 6-8-8 3.00 12 B1 Scale = 1:10.5 2 6-8-8 Plate Offsets X,Y : 3:Edge,0-3.8) LOADING(psf) �SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud' PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.46 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15,0 Lumber Increase 1.25 BC 0.27 Vert(TL) n/a n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) — Weight: 20 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-8-8 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=242/6-8-8, 3=242/6-8-8 Max Horz1=60(LC 3) Max Upliftl=-74(LC 3), 3=-89(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-37/37, 2-3=-188/105 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 44 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by ethers) of truss to bearing plate capable of withstanding 74 lb uplift at joint 1 and 89 lb uplift at joint 3. LOAD CASE(S) Standard Job Tru X07459 V8 ss VALLEY pe oty Ply 1 MORNINGSIDE MASTERS PHASE II Universal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf Job Reference optional) - 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:56 2008 Page 1 _ 8-8-8 8-8-8 Scale = 1:13. 3 - ' 3,00 12 2 T1 W2 i -W 1 I ---- -- - — 8-8-8 8-8-8 Plate Offsets X Y : 4:Edge,O^3-8] — _ -- - -- — -- — - LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.23 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.14 Vert(TL) n/a n/a 999 BOLL 10.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 28 lb LUMBER - — BRACING -- - --- - - - TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=150/8-8-8, 4=93/8-8-8, 5=421/8-8-8 Max Horz1=83(LC 3) Max Upliftl=-35(LC 3), 4=-34(LC 3), 5=-155(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-69143, 2-3=-37/12, 3-4=-73/41 BOT CHORD 1-5=0/0, 4-5=0/0 WEBS 2-5=-327/183 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber D0L=1.60 plate grip DOL=1.60 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 44 MT20 unless otherwise Indicated, 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 35 lb uplift at joint 1, 34 lb uplift at joint 4 and 155 lb uplift at joint 5. LOAD CASE(S) Standard City Job X07-459 V9 ss ITinTss LLEYpe — Ply =Reference MASTERSPHASEIIUniversal Forest Product, Inc. E359, Vero Beach, FI. 32967, James Shoaf o tional _ 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:56 2008 Page 1 f-- ----4-0-12------- 8-1-8 4-0-12 4-0-12 - Scale = 1:12. 2 5.00 FV2 T ST1 1 3 1 f- - - 8-1-8---- 8-1-8 LOADING(psf) SPACING 2-0-0 CSI DEFL In floc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.18 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.11 Vert(TL) n/a - n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) 0.00 3 n/a n/a BCDL 10.0 Code FBC20041TPI2002 (Matrix) Weight: 25 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=149/8-1-8, 3=14918-1-8, 4=303/8-1-8 Max Horz 1=-23(LC 6) Max Upiiftl=-56(LC 5). 3=-60(LC 6), 4=-59(LC 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-54/34, 2-3=-54/24 BOT CHORD 1-4=0/17, 3-4=0/17 WEBS 2-4=-219/64 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TQDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise Indicated. 5) Gable requires continuous bottom chard bearing. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 56 lb uplift at joint 1, 60 lb uplift at joint 3 and 59 lb uplift at joint 4. LOAD CASE(S) Standard Job Truss Truss Type Oty Ply MORNINGSIDE MASTERS PHASE II X07459 V10 GABLE 1� Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967, James Shoaf -- Job Reference (optional)_ 7.030 s Jan 3 2008 MiTek Industries, Inc. Tue Jan 29 10:15:56 2008 Page 1 ---- 10-8-8 10-8-8 Scale = 16.13 4 3.00 F12 3 2 Tt W 1 ci 5T2 ST1 1 10-8-8 10-8-8 Plate ets X,Y : 5:Ed e,0-3-81 -- LOADING(psf) TCLL 20.0 SPACING 2-0-0 CSI DEFL In (loc) I/deft Ud PLATES GRIP Plates Increase 1.25 TC 0.33 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.22 Vert(TL) n/a n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.04 Horz(TL) 0.00 5 n/a n/a BCDL 10.0 Code FBC20041TPI2002 (Matrix) -- Weight: 38 lb LUMBER BRACING ------------ --- -------------- TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=204/10-8-8, 5=115/10-8-8, 6=-12/10-8-8, 7=537/10-8-8 Max Horz1=105(LC 3) Max Upiiftl=-19(LC 3), 5=-44(LC 3). 6=-12(LC 1), 7=-199(LC 3) Max Grav1=204(LC 1), 5=115(LC 1), 6=7(LC 3), 7=537(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-77/37, 2-3=-55/0, 3-4=-22/6, 4-5=-81/45 BOT CHORD 1-7=-6/14, 6-7=-6/14, 5-6=-6/14 WEBS 3-6=-17/17, 2-7=-3B0/201 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 49 lb uplift at joint 1, 44 lb uplift at joint 5, 12 lb uplift at joint 6 and 199 lb uplift at joint 7. LOAD CASE(S) Standard