Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS_2
DATE 09/21/07 PAGE 1 Universal Forest Products RE: X07-458 CENTEX HOMES MODEL 1702 A Site Information: Project Customer: CENTEX HOMES Lot/block: Address: City: Project Name: MODEL 1702 A Model: 1702 A Subdivision: MORNINGSIDE State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions Design Code: FBC2004/TP12002 Wind Speed: 130 mph Roof Load: 20.0,15.0,0.0,10,0 Design Program: MiTek 20/20 6.3 Floor Load: 40.0,10.0,0.0,5.0 No. Job # Truss ID. Date No. Job # Truss ID. Date 1 X07-458 A01 09/21/07 26 X07-458 CJ5U 09/21/07 2 X07-458 A02 09/21/07 27 X07-458 E5 09/21/07 3 X07-458 A03 09/21/07 28 X07-458 E7 09/21/07 4 X07-458 A03A 09/21/07 29 X07-458 EG8 09/21/07 5 X07-458 A04 09/21/07 30 X07-458 EVA 09/21/07 6 X07-458 A04A 09/21/07 31 X07-458 EJ7U 09/21/07 7 X07-458 A05 09/21/07 32 X07-458 EJ8 09/21/07 8 X07-458 A06 09/21/07 33 X07-458 EJ8A 09/21/07 9 X07-458 61 09/21/07 34 X07-458 HJ2 09/21/07 10 X07-458 B2 09/21/07 35 X07-458 HJ7U 09/21/07 11 X07-458 B3 09/21/07 36 X07-458 K5 09/21/07 12 X07-458 B4 09/21/07 37 X07-458 K9 09/21/07 13 X07-458 B5 09/21/07 38 X07-458 V10 09/21/07 14 X07-458 B6 09/21/07 39 X07-458 V2 09/21/07 15 X07-458 B7 09/21/07 40 X07-458 V2A 09/21/07 16 X07-458 B8 09/21/07 41 X07-458 V4 09/21/07 1.7 --- -X07-458- B9 09/21/07 42 X07-458 V6 09/21/07 18 X07-458 C1 09/21/07 43 X07-458 V8 09/21/07 19 X07-458 C1A 09/21/07 44, X07-458 F01 09/21/07 20 X07-458 C3 09/21/07 45 X07-458 F02 09/21/07 21 X07-458 C3A 09/21/07 46 X07-458 F03 09/21/07 22 X07-458 C5 09/21/07 47 X07-458 F04 09/21/07 23 X07-458 CJ 1 09/21/07 48 X07-458 F05 09/21/07 24. X07-458 CJ1U 09/21/07 49 X07-458 F06 ,t,itnnr ; 09/21/07 25 X07-458 CJ3U 09121/07 a6/ 1/07 e The truss drawing(s) refrenced above have been prepared by MiTek Industries, Inc.V%�' under my direct supervision based on the parameters provided by UFP-Ft.Pierce, FL. Truss Design Engineer's Name: Tan, Seng-Chaff My license renewal date for,the state of Florida is February 28,2009. NOTE: The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSIlTPI-1 Chapter 2 tNo:- ��. sT Seng-Chaff Tan, FL Lic #46765 �. A% E of: 345 Alhambra PL '.� �'� 0 R 10 West Palm Beach, FL 33405 �i U1, ''• MiTek industries, Inc. ���is/01V .... •``_ � ` FL Cert.#6634 ���NIr IIIrN�ti��,, S EP 2 7 2007 This package includes 5 5 individual, dated truss design drawings and 0 Additional drawings. to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 C 5 of Florida Board of Professional Engineers Rules. Universal Forest Products DATE 09/21/07 PAGE 2 IRE: X07-458 CENTEX HOMES MODEL 1702 A Site Information: Project Customer: CENTEX HOMES Project Narne:MODEL 1702 A Lot/Block: Model: 1702 A Address: Subdivision: MORN INGSIDE City: State: No.' Job# Truss ID. Date 51 X07-458 FG1 09/21/07 52 X07-458 FG2 09/21/07 53 X07-458 FG3 09/21/07 54 X07-458 FG4 09/21/07 55 X07-458 FG5 09/21/07 Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 ;Job I Truss Truss Type - Oty Ply Centex Ho mes, Model 1702 A I i IX07-458 A01 COMMON 4 _ 1 — ---------- --- -- - — _ _ J_ob Reference optional)- ---- UniversallFW-W-6 Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:32 �gOg-61age 1 ! 1-0-0 6-9-3 14-0 0 21-2-13 28-0-0 9-0- j ! 1-0-0 6-9-3 7-2-13 7-2-13 6-9-3 1-0-0 - Scale = 1:50.0 d 0 5x5 = 5.00 12 5 12 11 10 4x4 = 4x4 = 18-8-0 'I 8-8-0 9-9-0 18-3-0 28-0-0 9-9-0 8-5-15 9-9-0 Plate Offsets X,Y)L4:0-3-0,Edge1, [5:0-2-8,Edge] [6:0-3-0 Edge] --- LOADING (pso SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.46 Vert(LL) -0.19 8-10 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.68 Vert(TL) -0.60 8-10 >558 180 BCLL 10.0 Rep Stress Incr YES WB 0.16 Horz(TL) 0.10 8 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 123 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-5-15 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-7-3 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1331/0-3-8, 8=1331/0-3-8 Max Horz 2=118(LC 5) Max Upiift2=-430(LC 5), 8=-430(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2529/714, 3-4=-2154/581, 4-5=-2056/603, 5-6=-2056/603, 6-7=-2154/581, 7-8=-2529/714, 8-9=0/27 BOT CHORD 2-12=-676/2271, 11-12=-322/1513, 10-11=-322/1513, 8-10=-559/2271 WEBS 3-12=-530/319, 5-12=-200/679, 5-10=-200/679, 7-10= 530/319 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) :This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x6 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 430 lb uplift at joint 2 and 430 lb uplift at joint 8. LOAD CASE(S) Standard - --- -------- - ------------- --- t Job Truss Truss Type ty rely Centex Homes, ModX07-458 A02 HIP 1 —.._.... i . --...--------- -- ---- --- ---- __ Job Reference UniversalApin, Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:JJ_Ye7 Page 1 1-0-0 1-0-0 6-3-14 12-0-0 16-0-0 5-8-2 4-0-0 21-8-2 28 0 Q_. ..... - .29_0_9 5-8-2 6-3-14 1-0-0 Scale = 1:51.01 i I 4x6 = i 4x6 = 4 5 - 5.00 12 — 1 i 3 W 3 2 6 I 1 I 1 2 7 1 8 ---.-----_ -- _ 0 -- ---- jo 4x6 = 11 10 9 4x6 = 5x6 = 18-8-0 18-8-0 I 6-10-1 14-0-0 21-1-15 28-0-0 i 6-10-1 7-1-15 7-1-15 6-10-1 i Plate Offs ,t1X�Y� LO-3-0,0=1-1� 15:0-3-0,0-1-121, [10:0-3-0,0-3-01. --- LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deli L/d __ PLATES GRIP TCDL 20.0 1'Plates Increase 1.25 TC 0.35 Vert(LL) -0.10 10 >999 360 MT20 2441190 i TCDL 15.0 Lumber Increase 1.25 BC 0.59 Vert(TL) -0.32 9-10 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.25 Horz(TL) 0.10 7 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 133 lb LUMBER BRACING TOP CHORD 2 X 4.SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-6-9 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-11-9 oc bracing. WEBS 2 X 4 SYP No.2 i REACTIONS (lb/size) 2=1331/0-3-8,-7=1331/0-3-8 Max Horz2=104(LC 5) Max Uplift2=-415(LC 5), 7=-415(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2607/661, 3-4=-2514/731, 4-5=-1720/486, 5-6=-2514/731, 6-7=-2607/662, 7-8=0/27 BOT CHORD 2-11=-616/2322, 10-11=-345/1691, 9-10=-318/1691, 7-9=-512/2322 WEBS 3-11=-391/256, 4-11=-306/775, 4-10=-50/206, 5-10=-50/206, 5-9=-306/775, 6-9=-391/256 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10,0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 1 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 415 lb uplift at joint 2 and 415 lb �upilft at joint 7. LOAD CASE(S) Standard Job iTruss iTruss Type i X07-458 � A03 I H I P Universalli7epffbt Product, Inc. E359, Vero Beach, FI. 32967 1-0-0 5-7-2 FJOWN&R-W Qty Pty Centex Homes, Model 1702 A 1 1 Job Reference.(optional 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54: JJ_?,087 Page 1 10-0-0 _ 18.0-0 22-4-14 28-0-0 9-0-q ' 4-4-14 8-0-0 4-4-14 5-7-2 1-0-0 Scale = 1:51 Oi I 5x7 = 4 5x10 5 5x5 = 11 10 9 5x5 = 5x8 = 4x6 = 18-8-0 18-8-0 10-0-0 18-0-0 28-0-0 10-0-0 B-0-0 10-0-0 PIS ets X,Y) 3-2,0-0-2117:0-3-2,0-02_ LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.57 Vert(LL) -0.23 7-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.79 Vert(TL) -0.67 7-9 >494 180 BCLL 10.0 Rep Stress Incr YES WB 0.15 Horz(TL) 0.11 7 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 128 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-8 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 8-2-6 oc bracing. WEBS 2 X 4 SYP No.2 WEBS 1 Row at midpt 5-11 REACTIONS (lb/size) 2=1331/0-3-8, 7=1331/0-3-8 Max Horz 2=90(LC 5) Max Uplift2=-398(LC 5), 7=-398(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2543/674, 3-4=-2177/604, 4-5=-1977/592, 5-6=-2176/604, 6-7=-2543/674, 7-8=0/27 BOT CHORD 2-11=-590/2286, 10-11=-443/1977, 9-10=-443/1977, 7-9=-558/2287 WEBS 3-11=-359/242, 4-11=-36/450, 5-11=-155/156, 5-9=-54/450, 6-9=-359/242 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 398 lb uplift at joint 2 and 398 lb jjplift at joint 7. LOAD CASE(S) Standard Job i j Truss ---.. Truss Type Qty Ply Centex Homes, Model 1702 A X07 458 J A03A SPECIAL 1 1 �--- ----- I Umversa o t Product, 11�-fib ------...--.--------___—.— -- Inc. E359, Vero Beach, FI. 32967 _ Job Reference o bor@ _____ —�'�-�--- 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:15g_02007 Page 1 , 18-0-0 21-3-0 28-0-0 9-0-0 1-0-0 5-7-2 4-4-14 8-0-0 3-3-0 6-9-0 1-0-0 i 0 5x7 = 4x6 Scale = 1:52.0 5x5 = 18 17 16 12 11 4x6 = 5x8 = 5x5 = 4x6 = 18-8-0 18-8-0 10-0-0 17-11-8 21-3-0 28-0-0 10-0-0 7-11-8 3-3-8 6-9-0 Plate Offsets (X,Y): [2:0-3-2,0-0-2], [4:0-5-4,0-2-8], [6:0-3-4,0-1-12], [8:0-2-0,0-1-12], [9:0-1-6,0-0-2], [11:0-2-0,0-2-0], [13:0-3-0,Edge], (14:0-2-0.0-0-8], [15:0-2-f 1`16:Edge,0-3-81, [17:0-2-8 0-3-01 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 i TC 0.43 Vert(LL) -0.24 2-18 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.72 2-18 >459 180 BCLL 10.0 I Rep Stress Incr YES WB 0.51 Horz(TL) 0.24 9 n/a n/a BCDL 10.0 1 Code FBC2004ITP12002 (Matrix) Weight: 153 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-8-5 oc purlins. BOT CHORD 2 X 4 "SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-10-9 oc bracing. Except: WEBS 2 X 4 SYP No.2 6-0-0 oc bracing: 7-13 REACTIONS (lb/size) 2=1331/0-3-8, 9=1331/0-3-8 8-0-0 oc bracing: 14-15 Max Horz 2=90(LC 5) Max Uplift2=-398(LC 5), 9=-398(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2564/685, 3-4=-2148/588, 4-5=-2988/845, 5-6=-2999/845, 6-7=-4554/1142, 7-8=-4446/1103, 8-9=-2674/669, 9-10=0/27 BOT CHORD 2-18=-595/2309, 17-1 8=-1 1157, 16-17=0/0, 14-15=-629/2744, 13-14=-629/2744, 12-13=-19/62, 7-13=-91/77, 11-12=-66/161, 9-11=-562/2392 WEBS 3-18=-437/259, 4-18=-269/1'12, 15-17=0/111, 5-15=-255/135, 6-15=-89/447, 6-13=-451/1892, 14-16=0163, 8-11=-1580/395, 11-13=-612/2748, 8-13=-374/1757, 15-18=-420/1956, 4-15=-348/1308 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3).Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 13. Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 398 lb uplift at joint 2 and 398 lb uplift at joint 9. LOAD CASE(S) Standard � Job ,Truss Truss Type Qty Ply I X07-458 iA04 HIP 1 1 rl_..-- - -------- — ---- I Universal18o[pst Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Fe j1-0.0 8-0-0 14-0-0 20-0-0 1-0-0 8-0-0 6-0-0 6-0-0 5.00 ;12 5x10 MT18H= 3 4 Homes, Model 1702 A ' i 0 5x10 MT18H= 5 Inc. FriSep 21 10:54:0g_W87 Pagel 8-0-0 1-0-0 Scale = 151.0 I' I' I7ii o� 4x6 = 10 9 8 4x6 = 5x8 = 18-8-0 18-8-0 8-0-0 14-0-0 _ 20-0-0 28-0-( 8-0-0 6-0-0 6-0-0 8-0-0 LOADING (psf) I SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d I PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.69 Vert(LL) -0.12 9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.70 Vert(TL) -0.41 6-8 >804 180 MT18H 244/190 BCLL 10.0 Rep Stress Incr YES WB 0.11 Horz(TL) 0.11 6 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 122 Ito LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-1-2 oc purlins. BOT CHORD 2 X 4 SY.P No.2 BOT CHORD Rigid ceiling directly applied or 8-1-10 oc bracing. WEBS 2 X 4 SY.P No.2 REACTIONS (lb/size) 2=1331/0-3-8, 6=1331/0-3-8 Max Horz 2=-77(LC 6) Max Uplift2=-389(LC 3), 6=-389(LC 4) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2502/700, 3-4=-2576/821, 4-5=-2576/821, 5-6=-2502/700, 6-7=0/27 BOT CHORD 2-10=-558/2208, 9-10=-556/2216, 8-9=-566/2216, 6-8=-567/2208 WEBS 3-10=0/329, 3-9=-163/577, 4-9=-374/194, 5-9=-163/577, 5-8=0/329 NOTES 1)'Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 4x4 MT20 unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 389 lb uplift at joint 2 and 389 lb uplift at joint 6. LOAD CASE(S) Standard Job Truss Truss Type — Qty Ply— Centex Homes, Model 1702 A X07-458 A04A II SPECIAL 1 1 __.... - - -- Un1versaltFBogebt Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:1mv?007 Page 1 1 i 1-0- 8-0-0 12-1t-12 17-11._8 — 20-0-0 1-3_0 24 3 10 28 0_0 9 O 1-0-0 8-0-0 4-11-12 4-11-12 2-0-8 1-3-0 3-0-10 3-8-6 1-0-0 Scale = 1:52.01 5x10 = 5.00 12 4x6 = 4x6 = 18 17 16 15 12 11 4x6 = 4x6 = 5x8 = 18-8-0 4x6 - 18-8-0 r 8-0-0 12-11-12 17-11-8 20-0-0 ,21-3-q 24-3-10 28-0-0 8-060 4-11-12 4-11-12 2-0-8 1-3-0 3-0-10 3-8-6 Plate Offsets LYj_j2:0+1-10,0-0-2L [6:0-3-0,0-1-121[9:0-1-6,0-0-2],[11:0-2-8,0-2-0L [13:0-2-8,Edge] [14:0-3-12 0-3-01,[15:Edge 0-3-81 [16:0-1-12 0-2-� LOADING (psf) , SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.64 Vert(LL) -0.21 13-14 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.60 13-14 >555 180 BCLL 10.0 Rep Stress Incr YES WB 0.45 Horz(TL) 0.23 9 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix), Weight: 146 lb LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 2-9-2 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-9-9 oc bracing. Except: WEBS 2 X 4 SYP No.2 6-0-0 oc bracing: 5-14, 7-13 REACTIONS (lb/size) 2=1331/0-3-8, 9=1331/0-3-8 Max Horz2=77(LC 5) Max Uplift2=-389(LC 3), 9=-389(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2495/698, 3-4=-2553/811, 4-5=-3818/1142, 5-6=-3875/1144, 6-7=-4464/1250, 7-8=-4424/1213, 8-9=-2701/729, 9-10=0/27 BOT CHORD 2-18=-555/2200, 17-18=-553/2208, 16-17=-553/2208, 15-16=-46/216, 14-15=0/116, 5-14=-241/130, 13-14=-865/3391, 12-13=-7/88, 7-13=-86/76, 11-12=-58/221, 9-11=-625/2425 WEBS 3-18=0/316, 3-16=-163/580, 4-16=-871/305, 14-16=-667/2423, 4-14=-359/1375, 11-13=-624/2425, 8-13=-406/1615 18-11=-1008/297,6-14=-220/726,6-13=-321/1302 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4).•This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 389 lb uplift at joint 2 and 389 lb uplift at joint 9. LOAD CASE(S) Standard Job ;Truss Truss Type — Qty IP1y Centex Homes, Model 1702 A 1 X07-458 : A05 HIP l_. Job Reference optiona_�------ UmversaliF)Ifv Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:jg:� _,087 Page 1 -4-0--..-_..--f---- �6 8-----i-----22---0 1-0-0 6-0-0 5-4-0 5-4-0 5-4-0 6-0-0 1.0-0 Scale = 1:51.0! I 5x7 = 5.00 f —12 ' 5x7 = 3 4 5 6 T] c: . J N 2 7 4x14 11 10 9 4x14 zz 5x10 MT18H = 18-8-0 18-8-0 6-0-0 14-0-0 22-0-0 28-0-0 l 6-0-0 8-0-0 8-0-0 6-0-0 Plate Offsets X,Y): [2:0-0=9,Edge],r3:0-3-4,0-2-81r6:0-3-4,0-2-81 [7:0-0-9 Edgel [9:0-1-12 0-2-0] [10:0-5-0 0-3-4] [11:0-1-12 0-2-0] LOADING (psf) SPACING 2-0-0 CSI DEFL in floc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.99 Vert(LL) 0.41 10 >816 360 MT20 244/190 j TCDL 15.0 Lumber Increase 1.25 BC 0.76 Vert(TL) -1.03 10-11 >324 180 MT18H 244/190 BCLL 10.0 Rep Stress Incr NO WB 0.33 Horz(TL) 0.26 7 n/a n/a BC, DL 10.0 —LUMBER Code FBC2004/TPI2002 (Matrix) Weight: 122 lb II BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied, BOT CHORD 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 4-2-14 oc bracing. WEBS 2 X 4 SYP No.2 WEBS 1 Row at midpt 4-11, 5-9 REACTIONS (lb/size) 2=242210-3-8, 7=2422/0-3-8 Max Horz 2=63(LC 5) Max Uplift2=-862(LC 3), 7=-862(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1.2=0/27, 2-3=-5283/1947, 3-4=-4850/1841, 4-5=-6793/2546, 5-6=-4850/1841, 6-7=-5283/1947, 7-8=0/27 BOT CHORD 2-11=-1717/4783, 10-11=-2499/6632, 9-10=-2502/6632, 7-9=-1729/4783 WEBS 3-11=-290/1195, 4-11=-2081/853, 4-10=01342, 5-10=0/342, 5-9=-2081/853, 6-9=-290/1195 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category ll; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3)'Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 4x4 MT20 unless otherwise indicated. 7)%Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 862 lb uplift at joint 2 and 862 lb uplift at joint 7. 8) Girder carries hip end with 6-0-0 end setback. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 315 lb down and 199 lb up at 22-0-0, and 315 lb down and 199 lb up at 6-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-6=-135(F=-65), 6-8=-70, 2-7=-39(F=-19) Concentrated Loads (lb) Vert: 3=-315(F) 6=-315(F) Job Truss Truss Type — Qty Ply Centex Homes, Model 1702 A' j X07�58 A06 HIP 1 1 i _ __ _ Job Reference o tional UniversallF��st Product, Inc. E359, Vero Beach, Fl. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:�A-:i087 Page 1 r1-0-Q 6-0-0 11-4-0 16-8.0 22-0-0 28-0-0 29-0-Q 1-0-0 6-0-0 5-4-0 5-4-0 5-4-0 6-0-0 1-0-0 Scale = 1:51.O J yi 0 5x8 = 5.00 12 5x8 = 3 12 4 5 13 14 6 4x14 = 11 15 16 17 18 10 19 20 21 22 9 4x14 = 5x5 = 7x10 MT18H= 5x5 = 18-8-0 18-8-0 6-0-0 14-0-0 I 22-0-0 28-0-0 6-0-0 8-0-0 8-0-0 6-0-0 LOADING (psf) i SPACING 2-0-0 CSI DEFL in (Ioc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.80 Vert(LL) 0.48 10-11 >688 360 MT20 244/190 TCDL 15.0 I Lumber Increase 1.25 BC 0.92 Vert(TL) -1.14 10-11 >293 180 MT18H 244/190 BCLL 10.0 I Rep Stress Incr NO WB 0.44 Horz(TL) 0.21 7 n/a n/a BCDL 10.0 I Code FBC2004/TP12002 (Matrix) Weight: 145 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 1-10-7 oc purlins. T2 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 4-6-0 oc bracing. BOT CHORD 2 X 6 SYP SS WEBS 1 Row at midpt 4-11, 5-9 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=289310-3-8, 7=2815/0-3-8 Max Horz2=-66(LC 6) Max Uplift2=-1115(LC 3), 7=-1092(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/32, 2=3=-6828/2656, 3-12=-6334/2520, 4-12=-6334/2520, 4-5=-9211/3687, 5-13=-6035/2408, 13-14=-6035/2408, 6-14=-6036/2408, 6-7=-6509/2537, 7-8=0/32 BOT CHORD 2-11=-2378/6225, 11-15=-3346/8517, 15-16=-3346/8517, 16-17=-3346/8517, 17-18=-3346/8517, 10-18=-3346/8517, 10-19=-3374/8504, 19-20=-3374/8504, 20-21=-3374/8504, 21-22=-3374/8504, 9-22=-3374/8504,7-9=-2283/5935 WEBS 3-11=-598/1860, 4-11=-2512/1033, 4-10=-348/977, 5-10=-306/983, 5-9=-2810/1183, 6-9=-521/1695 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3}Provide adequate drainage to prevent water ponding. 4) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 4x6 MT20 unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1115 lb uplift at joint 2 and 1092 lb uplift at joint 7. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 280 lb down and 219 lb up at 6-0-0, 133 lb down and 110 lb up at 8-0-12, 133 lb down and 110 lb up at 17-11-4, and 124 lb down and 101 lb up at 19-11-4, and 320 lb down and 219 Ito up at 22-0-0 on top chord, and 313 lb down and 67 lb up at 6-0-0, 76 lb down at 8-0-12, 268 ib down and 115 lb up at 9-6-12, 274 lb down and 121 lb up at 10-9-0, 274 lb down and 121 lb up at 12-9-0, 274 lb down and 121 lb up at 14-9-0, 268 lb down and 115 Ito up at 15-11-4, 76 lb down at 17-11-4, and 76 lb down at 19-11-4, and 313 lb down and 67 lb up at 21-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-6=-70, 6-8=-70, 2-7=-20 ICD 0 [russ Type -5�'- --r— : ;Job I truss Centex Homes, Model 1702 A F 1 X07-458 1 A06 HIP 1 Job Reference op On"'iver'sal Forest Product, Inc. E359, Vero Beach, -F-I.-3-296-7------- 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:35 2007 Page 2 LOAD CASE(S) Standard Concentrated Loads (1b) Vert: 3=-280(F) 6=-280(F) 11 =-312(F) 9=-312(F) 12=-133(F) 13=-1 33(F) 14=-124(F) 15=-38(F) 16=-268(F) 17=-274(F) 18=-274(F) 19=-274(F) 20=-268(F) 21=-38(F) 22=-38(F) i Job Truss Truss Type Oty —Ply Centex Homes, Model 1702 A X07-458 B1 HIP 1 1 _ Job Reference (optional) I Universal FQrBsaProduct. Inc. E359, Vero Beach. FI. 32967 - 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:5493B FJJ07 Page 1 i , ,-1-0-0 3-6-8 5-0-0 10-8-8 15-5-0 17-10-8 21-5-0 22-5-0 i 1-0-0 3-6-8 2-5-8 4-8-8 4-8-8 2-5-8 3-6-8 1-0-0 1 Scale = 1:39.7 I I 3.00 12 9-0-0 iE 4x4 11 12 4 13 14 10 15 16 9 17 18 8 4x4 11 5x10 MT18H= 44 11 9-0-0 6-0-0 10-8-8 15-5-0 17-10-8 21-5-0 3-6-8 2-5-8 4-8-8 4-8-8 2-5-8 3-6-8 Plate OffsetsX,Y): [2:0-4-9,Edgel [3:0-7-0,0-2-121, [5:0-7-0 0-2-121 r6:0-4-9,Edgel,[9:0-5-0 0-3-01 I LOADING (psf) SPACING 2-0-0 I CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.83 Vert(LL) 0.41 9 >612 360 MT20 244/190 TCDL 15.0 i Lumber Increase 1.25 BC 0.69 Vert(TL) -1.05 9 >238 180 MT18H 244/190 j BCLL 10.0 Rep Stress Incr NO WB 0.27 Horz(TL) 0.20 6 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 86 lb LUMBER TOP CHORD 2:X 4 SYP No.2 *Except* T2 2 X 4 SYP No.1 BOT CHORD 2�X 4 SYP SS WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1906/0-7-8, 6=1906/0-7-,8 Max Horz 2=37(LC 5) Max Uplift2=-732(LC 3), 6=-732(LC 4) v IM 6 BRACING TOP CHORD Structural wood sheathing directly applied or 1-10-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-8-4 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-6073/2159, 3-11=-7128/2601, 11-12=-7128/2601, 4-12=-7128/2601, 4-13=-7128/2601, 13-14=-7128/2601, 5-14=-7128/2601, 5-6=-6073/2160, 6-7=0/16 BOT CHORD 2-10=-2060/5817, 10-15=-2064/5863, 15-16=-2064/5863, 9-16=-2064/5863, 9-17=-2033/5863, 17-18=-2033/5863, 8-18=-2033/5863, 6-8=-2029/5817 WEBS 3-10=-47/589, 3-9=-552/1455, 4-9=-658/352, 5-9=-553/1455, 5-8=-48/589 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 5x10 MT20 unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 732 lb uplift at joint 2 and 732 lb - uplift at joint 6. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 262 lb down and 159 lb up at 6-0-0, 116 lb down and 81 lb up at 8-0-12, 116 lb down and 81 lb up at 10-0-12, 116 lb down and 81 lb up at 11-4-4, and 116 lb down and 81 lb up at 13-4-4, and 262 lb down and 159 lb up at 15-5-0 on top chord, and 350 lb down and 82 lb up at 6-0-0. 73 lb down at 8-0-12, 73 lb down at 10-0-12, 73 lb down at 11-4-4, and 73 lb down at 13-4-4, and 350 lb down and 82 lb up at 15-4-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pig Vert: 1-3=-70, 3-5=-70, 5-7=-70, 2-6=-20 - - - Job Truss HIP s Type Qty Ply 1 Cobentex Homes, Model 1702 A j X07-458 i B1 :_._ _.... . . - . . I.- — ... - -`-- - - -- -- --- ---- -- -- Reference Universal Forest Product, Inc. E359, Vero Beach, Ft. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:36 2007 Page 2 LOAD CASE(S) Standard Concentrated Loads (Ib) _ Vert: 3=-222(F) 5=-222(F) 10=-350(F) 8=-350(F) 11 =-1 16(F) 12=-116(F) 13=-116(F) 14=-116(F) 15=-36(F)16=-36(F) 17=-36(F) 18=-36(F) -- - .. - - ---- — - .- ----- -- Job iTruss It, Type iX07-458 IB2 HIP Universal F@EbsbProduct, Inc. E359, Vero Beach, FI. 32967 1-0-0 8-0-0 3.00 FlY -- — ---- - -- -- ------ -- Qty Ply Centex Homes, Model 1702 A i 1 1 Job Reference 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54g3B_�P07 Page 1 13-5-0 21-5-0 22-5-0 l 5-5-0 8-0-0 1-0-0 Scale = 1.39.7 5x10 = Sx6 = 3 4 —T2— rj 2 2 WI 5 - B;? - 6 o - 9-0-0 9 8 7 4x4 II 44 = 8-0-0 13-5-( 8-0-0 5-5-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d TCLL 20.0 Plates Increase 1.25 TC 0.59 Vert(LL) 0.14 2-9 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.47 2-9 >531 180 BCLL 10.0 Rep Stress Incr YES WB 0.11 Horz(TL) 0.09 5 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) LUMBER BRACING 8-0-0 9-0-0 PLATES GRIP MT20 244/190 Weight: 81 lb TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-1-9 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-3-14 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1030/0-7-8, 5=1030/0-7-8 Max Horz2=45(LC 5) Max Uplift2=-382(LC 3), 5=-382(LC 4) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD 1-2--0/16, 2-3=-2521/761, 3-4=-2386/768, 4-5=-2521/760, 5-6=0/16 BOT CHORD 2-9=-703/2374, 8-9=-701/2385, 7-8=-701/2385, 5-7=-665/2374 WEBS 3-9=0/274, 3-7=-252/253, 4-7=-4/274 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3,Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding, 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. i) All plates are 4x6 MT20 unless otherwise indicated. 3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 382 lb uplift at joint 2 and 382 lb uplift at joint 5. -OAD CASE(S) Standard -- -- - -- - -- ---- -- - i cuss Truss Type Qty Ply Centex Homes, Model 1702 A I ;X07 456 iB3 HIP 1 1 L- --- — --- — - -- t--- — --- -- —_ Job Reference o Gonalj------ Universal Fyf%Product, Inc. E359, Vero Beach, A. 32967 Feb 6.500 s 5 2007 MiTek Industries, Inc. Fri Sep 21 10:5419 :6107 Page 1 1-0-0 5-4-14 4-7-2 1-5-0 4-7-2 5-4-14 1-0-0 Scale = 1:39.7 i i i- 4x6 = 5x7 = 3.00, 12 4 5 3 IV?3 6 1 W I c 2 7 r� —g;- — --- — 132 7 l 0 0 4x6 = 10 9 4x6 = 5x10 = I I 9-0-0 900 10-0-0 11-5-0 21-5-0 10-0-0 1-5-0 10-0-0 I Plate Offsets X, 5:0-5-4,0-2-12 , 10:0-4-12 0-3-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.38 Vert(LL) -0.21 7-9 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.83 Vert(TL) -0.63 7-9 >396 180 BCLL 10.0 I Rep Stress Incr YES WB 0.25 Horz(TL) 0.10 7 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 93 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied 3-5-7 or oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-1-1 bracing. oc WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1030/0-7-8, 7=103010-7-8 Max Horz 2=-54(LC 6) Max Uplift2=-371(LC 3). 7=-371(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-2704/836, 3-4=-2088/569, 4-5=-1985/575, 5-6=-2073/565, 6-7=-2702/837, 7-8=0/16 BOT CHORD 2-10=-798/2582, 9-10=-464/1986, 7-9=-754/2580 WEBS 3-10=-636/323, 4-10=-72/320, 5-10=-164/159, 5-9=-43/323, 6-9=-648/327 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; ,cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2 and 371 lb Luplift at joint 7. LOAD CASE(S) Standard Job I Truss Truss Type Qty Ply Centex Homes, Model 1702 A , X07-458 84 COMMON 1 1 Uni6_&6I Forest Product, Inc E359, Vero Beach, FI. 32967 ____ Job Refere_ (9ptional)___._ _-.____-._ _____,- 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:37�.Ojl Page 1 5-10-12 10-8-8 15-6-4 21-5-0 22-5-0 5-10-12 4-9-12 4-9-12 5-10-12 1-0-0 I Scale = 1:37.2i 4x6 = 3.00 r2 3 4Xb = 9 8 7 4x6 = 4x6 = 9-0-0 15-1-1 9-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in floc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.32 Vert(LL) -0.17 7-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0,74 Vert(TL) -0.58 7-9 >427 180 BCLL 10.0 Rep Stress Incr YES WB 0.17 Horz(TL) 0.09 5 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 85 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-5-8 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-1-14 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=933/0-7-8, 5=1033/0-7-8 Max Horz 1=-61(LC 6) Max Upliftl= 279(LC 3), 5=-367(LC 4) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-2803/797, 2-3=-2685/795, 3-4=-2658/763, 4-5=-2776/764, 5-6=0/16 BOT CHORD 1-9=-761/2661, 8-9=-466/1803, 7-8=-466/1803, 5-7=-682/2632 WEBS 2-9=-330/197, 3-9=-280/935, 3-7=-253/906, 4-7=-321/189 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 279 lb uplift at joint 1 and 367 lb uplift at joint 5. LQAD CASE(S) Standard i Job Truss Truss Type Oty Ply Centex Homes Model 1702 A i I X07-458 B5 COMMON 1 1 1. ...._..-_...—.........—.__...- - - - --- — --_ ___ _ Job Reference (optional) - — -- - — — Uni�e�s -I Forest Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:3792 Page 1 ! 5-10-12 10-8-8 15-6-4 21-5-0 22-5-0 5-10-12 4-9-12 4-9-12 5-10-12 1-0-0 ' Scale = 1:37.2 3.00 12 4x6 = 3 4x6 = 9 8 7 4x6 = 4x6 = 9-0-0 9-0-0 _. 6-3-15 15-1-1 21-5-0 6-3-15 _ 8-9-2 6-3-15 _ LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ltd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.32 Vert(LL) -0.17 7-9 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.58 7-9 >427 180 BCLL 10.0 i Rep Stress Incr YES WB 0.17 Horz(TL) 0.09 5 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) -- Weight: 85 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-5-8 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-1-14 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=933/0-7-8, 5=1033/0-7-8 Max Horz 1=-61(LC 6) 'Max Upliftl=-279(LC 3), 5=-367(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-28031797, 2-3=-2685/795, 3-4=-2658f763, 4-5=-2776/764, 5-6=0/16 BOT CHORD 1-9=-761/2661, 8-9=-466/1803, 7-8=-466/1803, 5-7=-682/2632 WEBS 2-9=-330/197, 3-9=-280/935, 3-7=-253/906, 4-7=-321/189 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3)-'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 279 lb uplift at joint 1 and 367 lb uplift at joint 5. LOAD CASE(S) Standard Truss Type -- - Qty— --- -- - Ply Cente- x H— Homes, Model 1702 A ...__.._._.._.. - - - - -- i X07-458 i B6 SPECIAL 1 1 i - - _....—_.._.-- -- - - -� - --------- Univer bFerest Product, Inc. E359, Vero Bead CFb 32967 ---- -- -- Job Reference optional)- ---- 6.500 s Feb 5 2007 MiTek Industries, Inc. -----. ..._ Fri Sep 21 10:54:� GE47 Page 1 3-11-4 6-10-0 10-6-4 13-10-8 17-2-12 22-0-8 27-114 28:1.1-I4 i 3-11-4 2-10-12 3-8-4 3-4-4 3-4-4 4-9-12 5-10-12 1-0-0 Scale = 1:49.91 3.00 f12 4x6 = 1� 0 15 17 14 13 12 11 10 5x8 = 5x8 = 4x6 = 9-0-0 9-0-0 9-0-0 3-11-4 6-10-0 10-6-4 12-10-2 21-7-6 27-11-4 3-11-4 2-10-12 3-8-4 2-3-14 8-9-3 6-3-14 Plate Offset (X,YL_11:0-0-0,0-0-11,r2:0-5-4 0-2-81 [4:0-5-8 0-2-81 [8:0-5-12 0-0-21 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.74 Vert(LL) -0.16 10-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.64 Vert(TL) -0.50 10-12 >499 180 BCLL 10.0 Rep Stress Incr NO WB 0.58 Horz(TL) 0.05 8 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 120 lb LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=38/0-6-12, 14=1824/0-7-8, 8=926/0-7-8 Max Horz 1=-61(LC 6) Max Upliftl=-37(LC 5), 14=-569(LC 3), 8=-340(LC 4) Max Grav1=90(LC 7). 14=1824(LC 1), 8=926(LC 1) BRACING TOP CHORD Structural wood sheathing directly applied or 3-9-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-64/454, 2-16=-516/1839; 3-16=-516/1839, 3-4=-516/1839, 4-5=-1640/448, 5-6=-1670/494, 6-7=-2252/662, 7-8=-2370/663, 8-9=0/16 BOT CHORD 1-15=-402/80, 15-17=-392/84, 14-17=-392/84, 13-14=-254/836, 12-13=-258/850, 11-12=-345/1392, 10-11=-345/1392, 8-10=-584/2241 WEBS 2-15=0/191, 2-14=-1535/506, 3-14=-369/170, 4-14=-2777/816, 4-13=-101/28, 6-12=-86/374, 6-10=-256/921, 7-10=-330/191, 5-12=-275/150, 4-12=-168/815 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3);Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 37 lb uplift at joint 1, 569 lb uplift at joint 14 and 340 lb uplift at joint 8. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 213 lb down and 106 lb up at 3-11-4, and 79 lb down and 36 lb up at 6-0-0 on top chord, and 90 lb down at 3-11-4, and 33 lb down at 6-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (6). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-70, 2-4=-70, 4-6=-70, 6-9=-70, 1-8=-20 Concentrated Loads (lb) Vert: 2=-133(F) 15=-43(F) 16=-39(F) 17=-16(F) Job .. ... ........_..-....- -- `7Truss----------- X07-458 i67 Univer Merest Product, Inc. E359, Vero Beach, Fl. 5-11-4 5-11-4 3,00 r12 5x10 = Truss Type SPECIAL 6-7-0 Homes, Model 1702 A 11 Job Reference 6.500 s Feb 5 2007 MiTek I �.� 17-2-12 _ 22-0-8 4-8-8 4-9-12 4 Inc. Fri Sep 21 10:54:3_3(6)7 Page 1 i 27-11-4 _..__ __ 28:11 1 i 5-10-12 1-0-0 Scale = 1:50.0! iM J; 11 10 9 8 5x6 4x4 II 5x7 WB= 5x10 = 9-0-0 9-0-0 12-6-4 21-7-6 � 27-11-4 5-11-4 6-7-0 9-1-2 6-3-14 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 I Plates Increase 1.25 TC 0.91 Vert(LL) 0.44 8-9 >743 360 MT20 244/190 TCDL 15.0 i Lumber Increase 1.25 BC 0.93 Vert(TL) -1.35 8-9 >242 180 BCLL 10.0 Rep Stress Incr YES WB 0.57 Horz(TL) 0.17 6 n/a n/a� BCDL 10.0 Code FBC2004/TP12002 I (Matrix) Weight: 116 lb LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=1228/0-6-12, 6=1327/0-7-8 Max Horz 1=-61(LC 6) Max Upliftl=-388(LC 3), 6=-424(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-3950/1234, 2-3=-5470/1645, 34=-5845/1790, 4-5=-3784/1008, 5-6=-3899/1004, 6-7=0/16 3OT CHORD 1 -11 =-1 185/3773, 10-11 =-1 18213785, 9-1 0=-1 182/3785, 8-9=-815/2930, 6-8=-934/3715 NEBS 2-11=0/235, 2-9=-436/1732, 3-9=-1764/634, 4-9=-975/3099, 4-8=-242/885, 5-8=-295/182 VOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 1) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. i) All plates are 5x7 MT20 unless otherwise indicated. 3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 388 lb uplift at joint 1 and 424 lb ;uplift at joint 6. -OAD CASE(S) Standard Job Truss _...__ ....- -Type--- ..--- - --- - —... , Truss Qty Ply Centex Homes, Model 1702 A X07 458 iB8 SPECIAL 1 1 ____ _-___._JobRefenm; o tional Unrver� .8rest Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54: 7 Page 1 ' a� 14-6-4 _ 17-2-12 22-0-8 27-11-4 8-11- t 7-11-4 6-7-0 2-8-8 4-9-12 5-10-12 1-0-0 Scale = 1:50.OI 3.00 12 5x10 = 4x6 = 4x6 = 4 , a C; 6 oxb = 11 10 9 8 5x6 = 5x8 = 46 = 9-0-0 • 7-11-4 14-6-4 21-7-6 9-0-0 27-11-4 7-11-4 6-7-0 7-1-2 6-3-14 Plate Offsets-_�Y)_[1:0-3-13,EdgET [2:0-4 -12 0-2-e1 [3 0-2-8 0-2 4] [4 0-2-8 0-2-01 (6 0 4 9 Edgel LOADING (psf) TCLL 20.0 SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCDL 15.0 Plates Increase 1.25 Lumber Increase 1.25 TC 0.76 Vert(LL) -0.30 10 >999 360 MT20 2441190 BCLL 10.0 Rep Stress Incr YES BC 0.94 WB 0.34 Vert(TL) -0.90 Horz(TL) 0.17 8-10 6 >365 180 BCDL 10.0 Code FBC2004/TPI2002 I (Matrix) n/a n/a Weight: 115 lb LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 2-3-5 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=122810-6-12, 6=1327/0-7-8 Max Horz 1=-61(LC 6) Max Upliftl=-388(LC 3), 6=-423(LC 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-3732/1154, 2-3=-4172/1256, 3-4=-4418/1350, 4-5=-3756/1015, 5-6=-3872/1011, 6-7=0/16 BOT CHORD 1-11=-1094/3549, 10-11=-1092/3562, 9-10=-800/2928, 8-9=-800/2928, 6-8=-942/3691 WEBS 2-11=0/309, 2-10=-190/640, 3-10=-1339/484, 4-10=-591/1845, 4-8=-257/836, 5-8=-306/185 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4,2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 388 lb uplift at joint 1 and 423 lb uplift at joint 6. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X07-458 169 SPECIAL 1 1 ._... __ __......_---_--__,_______ Job Reference o.tional i Univervl-Brest Product, Inc. E359, Vero Beach, FI. 32967 ---- (p— _ Z--___....—_._.__.__ _ _ __ ._ . . 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:4 a�7 5-4-2 16-6-4 1 -2- 2 22-0-8 27-11-4 5-4-2 4-7-2 6-7-0 0-8-8 4-9-12 5-10-12 3.005x6 = 4X6 = 5X8 -- 3 4 5 8-11- Scale = 1:50.01 oxo — 12 11 10 9 5x6 -- 5x8 = 4x6 = 9-0-0 9-11-4 16-6-4 21-7-5 9-0-0 27-11-4 9-11-4 6-7-0 5-1-1 6-3-15 Plate Offsets Edge], (3:0-3-0 0-2-121 f4.0-5-4,0-3-41 [5:0-3-0 0-1-121 (7:0-4-9 Edge] 1`10:0-1-12 0-2-01 —_ LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 TCDL 15.0 1 Plates Increase 1.25 Lumber Increase 1.25 TC 0.50 Vert(LL) -0.25 1-12 >999 360 MT20 244/190 BCLL 10.0 i Rep Stress Incr YES BC WB 0.93 0.24 Vert(TL) -0.83 Horz(TL) 0.17 1-12 >394 7 180 BCDL 10.0 Code FBC2004ITP12002 (Matrix) n/a n/a Weight: 123 lb LUMBER TOP CHORD 2 X 4 SYP N0.2 BOT CHORD 2 X 4 SYP N0.2 WEBS 2X4SYP N0.2 REACTIONS (lb/size) 1=1228/0-6-12, 7=1327/0-7-8 Max Horz 1=-61(LC 6) Max Upliftl=-388(LC 3), 7=-421(LC 4) BRACING TOP CHORD Structural wood sheathing directly applied or 2-8-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-3795/1241, 2-3=-3286/1008, 3-4=-3175/1005, 4-5=-3454/1074, 5-6=-3728/1014, 6-7=-3844/1011, 7-8=0/16 BOT CHORD 1-12=-119113632, 11-12=-913/3277, 10-11==913/3277, 9-10=-803/2969, 7-9=-941/3664 WEBS 2-12 515/280, 3-12=-31/438, 4-12=-251/125, 4-10=-1133/464, 5-10=-458/1292, 5-9=-254/769, 6-9=-299/179 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3)-Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 388 lb uplift at joint 1 and 421 lb - uplift at joint 7. LOAD CASE(S) Standard lob '•Truss I 1 X07-458 I C 1 I Universal Fo I I 1 - I 1 I Truss Type Qty Ply Centex Homes, Model 1702 A 9-4-6 JACK 5J1 Job Reference (optional) 4x4 = 1-6-0 LOADING (psf) I SPACING 2-0-0 CSI DEFL in (]cc) I/deft L/d TCLL 20.0 I Plates Increase 1.25 TC 0.08 Vert(LL) -0.00 2 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL)- -0.00 2 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) LUMBER TOP CHORD 2 X 4 SYP N0.2 BOT CHORD 2 X 4 SYP No.2 REACTIONS (lb/size) 2=171/0-7-8, 4=14/Mechanical, 3=20/Mechanical Max Horz 2=34(LC 3) Max Uplift2=-115(LC 3). 3=-12(LC 4) Max Grav2=171(LC 1), 4=28(LC 2), 3=20(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-21/3 BOT CHORD 2-4=0/0 PLATES GRIP MT20 244/190 Weight: 6 lb BRACING TOP CHORD Structural wood sheathing directly applied or 1-6-0 cc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 115 Ib uplift at joint 2 and 12 Ib uplift at joint 3. LOAD CASE(S) Standard i I 1� .6' Job Truss -.._. Truss Type �X07-458 IC3 - - JACK Universal Forest Product, Inc. E359, Vero Beach, �j.,?A967 4x4 = aty Ply Centex Homes, Model 1702 A 5 1 Job Referen9-8-14 i ce o Gonal — _ _ i 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:39 2007 P�g�a LOADING (psf) SPACING 2-0-0 I CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.12 Vert(LL) -0.00 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) -0.01 2-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 11 lb LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=68/Mechanical, 2=237/0-7-8, 4=26/Mechanical Max Horz2=51(LC 3) Max Uplift3=-30(LC 3), 2=-141(LC 3) Max Grav3=68(LC 1), 2=237(LC 1), 4=53(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-32/14 BOT CHORD 2-4=0/0 NOTES 1) Wind:.ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4} Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 30 lb uplift at joint 3 and 141 lb uplift at joint 2. LOAD CASE(S) Standard Truss (- -- - _ .. __�russ Type j X07-458 i C3A JACK Universal Forest Pr . In .. ` --` ---- -- o6t,dnc. E359, Vero Beach, FI. 32967 I 2-11-4 Qty Ply Tob odel 1702 A 9-8-14 _ Reference(optional _ 6.500 s Feb 5 2007 MTek Industries, Inc. Fri Sep 219 8_b4:39 2007 Page 1 ; i i I Scale = 1:6.11 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defi Ltd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.11 Vert(LL) -0.00 1-3 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.06 Vert(TL) -0.01 1-3 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horc(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 9 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc puriins BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1 =1 17/0-6-12, 2=91/Mechanical, 3=26/Mechanical Max Horz 1=34(LC 3) Max Upliftl=-34(LC 3), 2=-52(LC 3) Max Grav1=117(LC 1), 2=91(LC 1), 3=52(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-20/20 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 21 *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 34 lb uplift at joint 1 and 52 lb uplift at joint 2. L-9AD CASE(S) Standard ;Job . _... _..... Truss '- — — - Truss Type I X07-458 I CS JACK Universal Forest Product, Inc. ff�'jo Beach, FI. 32967 1-0-0 2 �Qty Ply Centex Homes. Model 1702 A I 4 1 ----(- 10-2-141 ----- �--_— ---- Job Reference optional)-----....------- -----...-. . _. .. � 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:39 2007 O�V_d i ---- ---- — — — - -- 5-0-0---- — --- -- --- — '- -- — — - 5-0-0 Scala = 1: ia.b 3.00 12 T1 B1 4 9-0-0 4x4 = LOADING (psf) I SPACING 2-0-0 CSI DEFL in (loc) Ildefl L/d PLATES GRIP TCLL 20.0 1 Plates Increase 1.25 TC 0.28 Vert(LL) -0.02 2-4 >999 360 MT20 244/190 I TCDL 15.0 Lumber Increase 1.25 BC 0.20 Vert(TL) -0.06 2-4 >924 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 17 lb LUMBER BRACING 10-2-1 9-0-0 TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=148/Mechanical, 2=316/0-7-8, 4=46/Mechanical — Max Horz2=73(LC 3) Max tJp1ift3=-79(LC 3). 2=-159(LC 3) Max Grav3=148(LC 1), 2=316(LC 1), 4=93(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-46/30 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4}Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 3 and 159 lb uplift at joint 2. LOAD.CASE(S) Standard e -... -t-r� -. `-- - ..... Job Truss Truss Type r ty Ply Centex Homes, Model 1702 A 19-0-10 X07-458 1 CJ 1 JACK 2 1 _ Job Reference o Goner -- Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, 3 c. Frig �1 10:54:40 2007 Page 1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL 20.0 Plates Increase 1.25 TC 0.13 Vert(LL) -0.00 2 n/r 180 TCDL 15.0 Lumber Increase 1.25 BC 0.05 Vert(TL) -0.00 2 n/r 90 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) LUMBER TOP CHORD 2 X 4 SYP N0.2 BOT CHORD 2 X 4 SYP No.2 REACTIONS (Ib/size) 4=10/Mechanical, 3=153/Mechanical Max Horz 4=-351(LC 1), 3=351(LC 1) Max Uplift4=-14(LC 3). 3=-116(LC 5) Max Grav4=20(LC 2), 3=153(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-324/380 BOT CHORD 2-4=-351/348 Scale = 1: 18-8-0 PLATES GRIP MT20 244/190 Weight: 5 lb BRACING TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 Ito uplift at joint 4 and 116 lb uplift at joint 3. 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard ------ - - -- --- -- - -- .......... . , Job I Truss Truss Type -- ----- -- Qty Ply 1 X07458 ! CA U JACK 8 Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 8-8-0 6.500 Centex Homes, Model 1702 A 19 0 10 I 1 , Job Reference LpGonal s Feb 5 2007 MiTek Industries, 13nc. FhT%eg_a1 10:54:40 2007 Page 1 4x4 = 1-0-0 LOADING (psf) ! SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d TCLL 20.0 i Plates Increase 1.25 TC 0.08 Vert(LL) -0.00 2 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 0.01 Vert(TL) -0.00 2 >999 180 SCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) LUMBER BRACING PLATES GRIP MT20 244/190 Weight: 5 lb ! i Scale = 1:4.8 TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD 2 X 4 SYP N0.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=16210-3-8, 4=10/Mechanical, 3=-9/Mechanical Max Horz2=49(LC 5) Max Uplift2=-122(LC 5), 3=-9(LC 1) Max Grav2=162(LC 1), 4=19(LC 2), 3=22(LC 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-32/9 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 122 lb uplift at joint 2 and 9 lb uplift at joint 3. -OAD CASE(S) Standard ----_...- ---------- - �Job ._ ......._ Truss ..--.-------------- -----------------...------....__.. _.._-- -- ----- ..._.. Truss Type I Ply Centex Homes, Model 1702 A I I ' IX07-458 1CJ3U JACK 8 1 19-10-10 ...- -- --- - I - -------�-----------------• -- -- 1-- Job Reference (o�Uonal ------ --- ------ - - .- _. Universal Forest Product, Inc. E359, Vero Beach, FI. 329%8-0 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10i3gi(b2007 Page 1 le: 1.5"= 1' 3-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.10 Vert(LL) -0.00 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) -0.01 2-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004lTPI2002 (Matrix) Weight: 11 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=80/Mechanical, 2=228/0-3-8, 4=28/Mechanical Max Horz2=85(LC 5) Max Uplift3=-45(LC 5). 2=-123(LC 5) Max Grav3=80(LC 1), 2=228(LC 1), 4=56(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-48/25 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2.) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 45 lb uplift at joint 3 and 123 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss I Truss Type ) Qty Ply Centex Homes, Model 1702 A !X07-458 CJSU (JACK 8 1 JobReference o tional 20-8-10 _— - . .. -- -- ---- --- ---- -�.P— L-- -------10 .. j Universal Forest Product, Inc. E359, Vero Be Fg Fd. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 1%5g_b0 2007 Page 1 •1-n-n r-n-n •�r. �.,,.., •.. x, ,, 1 — inncla lgllll.gl,G—aIV/V-YO, 9=q0/IVICGfId1IIGdl Max Horz 2=122(LC 5) Max Uplift3=-97(LC 5), 2=-138(LC 5) Max Grav3=157(LC 1), 2=310(LC 1), 4=96(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-71/49 BOT CHORD 2-4=0/0' NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 97 lb uplift at joint 3 and 138 lb uplift at joint 2. LOAD CASE(S) Standard job- !Tru,*ss, rTrussType Qty Centex Homes, Model 1702 A X07-458 Ell JACK 2 1 __ _ I _ Job Reference _(qpqgnajl Inc.! F Universal Forest Product, yi�9. rq.E�35ch. Fl. 32667 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:41 2007 Pad 100 1-0-0 4-0-0 Sc?hle 3.00 F1 2 2 T1 131 4 9-11-14 9-0-0 4x4 = 9-0-0 4-0-0 4-0-0 LOADING (pso I SPACING 2-0-0 CS1 DEFIL in (loc) Ildefi L/d PLATES GRIP TCLL 20.0 I Plates Increase 1.25 TC 0.16 Vert(LL) -0.01 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.12 Vert(TL) -0.02 2-4 >999 180 BCLL 10.0 i Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n1a n/a BCDL 10.0 Code FBC2004TP12002 Matrix LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=109/Mechanical,2=275/0-7-8,4=36/MechanicaI Max Horz 2=62(LC 3) Max LIplift3=-56(LC 3), 2=-149(LC 3) Max Grav3=109(1-C 1), 2=275(LC 1), 4=73(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0116,2-3=-39/23 SOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf*, Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=11.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4)-Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 56 lb uplift at joint 3 and 149 lb uplift at joint 2. LOAD CASE(S) Standard ; Job Truss TTruss Type i I X07-458 I E7 I JACK Universal Forest Product, Inc. �5� Vero Beach, FI. 32967 I I- 1-0-0 i r4�,1 a 2 9-0-0 4x4 = ----. - —----.-.---... .. ---- ---.--- �- -...— -- . — �— -- ...... __.... aty Ply Cente--.x Homes, Model 1702 A 6 1 Job Reference o Gonal 10-5-14 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:41 2007 PC3-F-d ! ---- — — 6-0-0 ---- — - — -- — 6-0-0 3.00 F12 T1 61 LOADING SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d TCLL 20.0 20.0 Plates Increase 1.25 TC 0.45 Vert(LL) -0.05 2-4 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 0.30 Vert(TL) -0.13 2-4 >514 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) LUMBER TO BRACING Scal&J= 1: PLATES GRIP MT20 244/190 Weight: 20 lb 4 10-5-1 9-0-0 P CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=186/Mechanical, 2=359/0-7-8, 4=56/Mechanical Max Horz2=84(LC 3) Max Uplift3=-101(LC 3), 2=-171(LC 3) Max Grav3=186(LC 1), 2=359(LC 1), 4=113(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-54/38 BOT CHORD 2-4=0/0 VOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. i) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift at joint 3 and 171 lb uplift at joint 2. r -OAD CASE(S) Standard J Job Truss Truss Type pty Ply Centex Homes, Model 1702 A I X07-458 i EG8 SPECIAL 2 1 Job Reference�tlonalZ_—------- —-----1$ 8 0--- Universal Forest Product, Inc. F� E359, Vero Beach, 83�7 — 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:41 2007 Page 1 I ; 1-0-0 2-0-0 1-0-0 4-0-0 6 14.( v 18-A� II 1-0-0 2-0-0 3-0-0 7-0-0 1-0-0 1-0-0 1-0-0 4-0-0 Plate Offsets (X,Y): [2:0-1-0,0-11-61. r2:0-1-14 Edge1 [4:0-4-5,0-2-4], [7:Edge 0-3-81^ LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.37 Vert(LL) 0.02 8 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.34 Vert(TL) -0.05 7-8 >999 180 BOLL 10.0 Rep Stress Incr NO WB 0.02 Horz(TL) 0.00 7 n/a n/a BCDL 10.0 t I Code FBC2004/TP12002 (Matrix) Weight: 34 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2 X 4 SYP No.2 except end verticals. Except: WEBS 2 X 4 SYP No.2 6-0-0 oc bracing: 4-5 WEDGE BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 7=288/Mechanical, 2=376/0-3-8 Max Horz2=140(LC 5) Max Uplift7=-109(LC 5), 2=-149(LC 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-406/26, 3-4=-340/28, 4-5=-334/80, 4-6=-53/50, 5-7=-202/109, 5-6=-143/82 BOT CHORD 2-8=-111/342, 7-8=-99/339 WEBS 3-8=-16/98 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) Provide adequate drainage to prevent water ponding. 3) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 41 All plates are 4x4 MT20 unless otherwise indicated. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 109 lb uplift at joint 7 and 149 lb uplift at joint 2. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-1 Od nails. a) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 21 lb down and 24 lb up at 2-0-0 on top chord, and 0 lb up at 2-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-4=-70, 4-6=-70, 2-7=-20 Concentrated Loads (lb) Vert: 3=24(B) 8=0(B)- Job iTruss XO7458 I EJ7A I Universal Forest Product, Inr1.8Eg_V, Vero E I I, MONO TRUSS a-n-n 2 1 1 6.500 s Feb 5 2007 Model 1702 A , v 21-1-10 18-8-0 4x4 = 18-8-0 1 2007 Page 1 i Scale = 1:13.9 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP T.CLL 20.0 Plates Increase 1.25 TC 0.53 Vert(LL) -0.06 1-3 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.32 Vert(TL) -0.15 1-3 >471 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 19 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=261/0-3-8, 2=203/Mechanical, 3=58/Mechanical Max Horz 1=112(LC 5) Max, Uplift1=-64(LC 5), 2=-130(LC 5) Max Grav1=261(LC 1), 2=203(LC 1). 3=116(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-69/64 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load.nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 64 lb uplift at joint'l and 130 lb uplift at joint 2. LOAD CASE(S) Standard r- ----.... ... .. ... _. . i.. .. ...----...... ------ -- Job I Truss Truss Type X07-458 EVU I MONO TRUSS i Universal Forest Product, Inc. E359, Ver"_%ch, FI. 32967 .1_n_n 14 i 9 -- --- — ------------ rQty Ply---- — Centex Homes, Model 1702---- A ------- Reference o tional 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10V4b2007 Page 1 i le = 1:13.9! 18-8-0 4x4 = 18-8-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d TCLL 20.0 Plates Increase 1.25 TC 0.49 Vert(LL) -0.06 2-4 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 0.32 Vert(TL) -0.15 2-4 >471 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 REACTIONS (lb/size) 3=194/Mechanical, 2=353/0-3-8, 4=58/Mechanical Max Horz2=141(LC 5) Max Uplift3=-121(LC 5), 2=-147(LC 5) Max Grav3=194(LC 1), 2=353(LC 1). 4=116(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-68/61 BOT CHORD 2-4=0/0 PLATES GRIP MT20 244/190 Weight: 20 lb BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1,60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 121 lb uplift at joint 3 and 147 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss..._. t X07-458 iEJ8 SPECIAL Universal i..-- - Forest Product, Inc. E359, Vero Beach, Fge310 7 l -1-0-0 1-0-0 3-2-4 Qty Ply Centex Homes, Model 1702 A 2 1 Job Reference optional� 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:42 2007 Page 1 1-0-0 2-9-12 6 14.( 18-6X$ If 1-0-0 111-12 3-2-4 4-2-4 7-0-0 i 1-0-0 0-1-12 2-0-8 1-0-0 2-9-12 LOADING (psf) I SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.47 Vert(LL) 0.03 8 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.34 Vert(TL) -0.06 2-8 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.01 Horz(TL) 0.00 7 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 33 lb LUMBER BRACING TOP CHORD 2,X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2X 4 SYP No.2 except end verticals. Except: WEBS 2 X 4 SYP No.2 6-0-0 oc bracing: 4-5 WEDGE BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. Left: 2 X 4 SYP No,2 REACTIONS (lb/size) 7=294/Mechanical, 2=394/0-3-8 Max Horz2=140(LC 5) Max Uplift7=-115(LC 5), 2=-164(LC 5) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-355/40, 3-4=-275/51, 4-5=-365/124, 4-6=-56/132, 5-7=-193/97, 5-6=-127/68 BOT CHORD 2-8=-107/277, 7-8=-100/274 WEBS 3-8=-27/70 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) Provide adequate drainage to prevent water ponding. 3) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise indicated. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 115 lb uplift at joint 7 and 164 lb uplift at joint 2. 7) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. LOAD CASE(S) Standard ;Job iTruss — Truss Type X074511 EJ8A SPECIAL Universal Forest Product, Inc. E359, Vero Beach, F4833167 Qty Ply Centex Homes, Model 1702 A 1 1 i Job Reference optional 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:42 2007 Page 1 1-0-0 5-2-4 1-0-0 5-24 1-0-0 0-9-153 14.1 9 18-64 1 1-0-0 1,1-12 5-2-4 7-0-0 1-0-0 0-1-12 4-0-8 1-9-12 LOADING (psf) TCLL 20.0 TCDL 15.0 BCLL 10.0 BCDL 10.0 _ SPACING 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr YES Code FBC2004/TPI2002 CSI TC 0.36 BC 0.30 WB 0.05 (Matrix) DEFL in Vert(LL) -0.02 Vert(TL) -0.05 Horz(TL) 0.00 (loc) I/deft L/d 2-7 >999 360 2-7 >999 180 6 n/a n/a PLATES GRIP MT20 244/190 Weight: 37 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2 X 4 SYP No.2 except end verticals. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 6=294/Mechanical, 2=394/0-3-8 Max Horz 2=140(LC 5) Max Uplift6=-115(LC 5), 2=-164(LC 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-275/10, 3-4=-176/42, 4-5=-7/7, 5-6=-23/15 BOT CHORD 2-7=-60/184, 6-7=-28/87 WEBS 3-7=-1221101, 4-7=-70/249, 4-6=-300/98 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) Provide adequate drainage to prevent water ponding. 3) 'This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. �) All plates are 44 MT20 unless otherwise indicated. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 115 lb uplift at joint 6 and 164 lb uplift at joint 2. LOAD CASE(S) Standard Job ;Truss uss Type Oty Ply Centex Homes, Model 1702 A 1 I X07-458 F01 OOR 4_ _. _._.......___._L-,--JFL ------------ Job Reference(optional)1 ' ---- ---- --- ----------------_..-_... - ---- -i Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 6,500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:42 2007 Page 1 I I 0-1-8 i I 2-2-0 2-6-0 2-0-6 2-0-0 1-8-6 i lid..._.__..--f----------{I-----�I------it---I i 2x3 11 3x6 = 2x3 II 3x5 = 2x3 II 3x6 FP= 1 2 3 4 5 R 7 a o 0-f�-8 Sca e: 1/4"=l' 2x3 11 2x3 11 2x3 11 1n 11 19 14 9A 1 28 27 24 23 22 21 20 19 18 17 16 15 -3x6 = 2x3 11 2x3 11 3x6 = 3x6 FP = 3x7 = 8-2-6 9-3-14 23-0-10 0-0 7-0-14 7-2-6 9-2-6 16-3-4 21-0-102--0-1P 2312-2 27-10-8 9-0-0 9-0 -0 �2 7-0-14 0-1-8 1-0-0 6-11-6 4-9-6 1-0-0 1-0-0 4-8-6 1-0-0 0-1-8 1 0-1-8 Offsets (X,Y): [4:0-1,8,Edge], [5_0_1-8,Edge], [11:0-1-8,Edge], [12:0-1-8,0-0-0], [14:0-1-8,Edge], (16:0-1-8,Edge], (17:0-1-8,Edge], [18:0-2-4,Edge], [20:0-1.8,E LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.56 Vert(LL) -0.14 22-23 >999 480 MT20 2441190 TCDL 10.0 Lumber Increase 1.00 BC 0.73 Vert(TL) -0.20 22-23 >959 240 BCLL 0.0 Rep Stress Incr YES WB 0.31 Horz(TL) 0.04 15 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 145 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, SOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 REACTIONS (lb/size) 24=815/0-7-4, 15=53110-6-12, 18=1679/0-8-0 oc bracing: 17-18. Max Grav24=846(LC 7), 15=583(LC 4), 18=1679(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 24-25=-87/0, 25-26=-87/0, 1-26=-87/0, 15-27=-103/0. 27-28=-103/0, 14-28=-103/0, 1-2=0/0, 2-3=-1863/0, 3-4=-1863/0, 4-5=-2083/0, 5-6=-1771/0, 6-7=-177110, 7-8=-1771/0, 8-9=0/859, 9-10=0/859, 10-11=-985/0, 11-12=-985/0, 12-13=-985/0, 13-14=0/0 BOT CHORD 23-24=0/1070, 22-23=0/2083, 21-22=0/2083, 20-21=0/2083, 19-20=0/949, 18-19=0/949, 17-18=-215/595, 16-17=0/985, 15-16=01761 WEBS 4-22=-110/49, 5-21=-32/142, 11-17=-318/0, 12-16=-147/46, 9-18=-287/0, 2-24=-1301/0, 2-23=0/913, 3-23=-289/0, 4-23=-382/30, 13-15=-889/0, 13-16=-61/282, 10-18=-1129/0, 10-17=01658, 8-18=-159510, 8-20=011049, 6-20=-239/32, 5-20=-628/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 19 and 7. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard --........ Trt;-ss Type Qty Ply -Centex Homes, Model 1702 A-- - i X07 458 i F02 FLOOR 2 1 Job Referenceoptional) - .._ Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:43 2007 Page 1 0-1-8 i i 2x3 11 2x3 II 3x6 FP= 3x6 = 3 4 5 fi 7 R 018 Sc 1 /4"=1 2x3 11 2x3 11 2x3 11 Q 1n 11 17 114 1d 1 28 _ 27 1 24 23 22 21 20 19 18 17 16 15 3x6 = 2x3 II 2x3 II 3x7 = 3x6 FP= 3x7 = 8-2-6 9-3-14 23-0-10 9-0-0 -0-0 7-0-14 7-2-6 ,9-2-6 16-8-4 9-0-0 21-0-10 22-0-1p 23,2-2 27-10-8 7-0-14 0-1-8 1-0-0 7-4-6 4-4-6 1-0-0 1-0-0 4-8-6 1-0-0 0-1-8 0-1-8 Offsets (X,Y): [4:0-1-8,Edge], [5:o-1-8,Edge], [8:0-2-12,Edge], [11:0-1-8,Edge], [12:0-1-8,0-0-0], [14:0-1-8,Edge], [16:0-1-8,Edge], [17:0-1-8,Edge], [18:0-2-4,E -_--_ [20:0-2-4,Edge],I�0-1-8,0-0-01, [22:0-1-8,Edge], f25:0-1-8,0-1-81. f26:0-1-8.0-1-81. 1`27:0=1-8.0-1-81. r28:0-1-8.0-1-81 LOADING (psf) j SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.66 Vert(LL) -0.14 22-23 >999 480 MT20 2441190 TCDL 10.0 Lumber Increase 1.00 BC 0.72 Vert(TL) -0.22 15-16 >607 240 BCLL 0.0 Rep Stress Incr YES WB 0.32 Horc(TL) 0.05 15 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 145 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purllns, BOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: REACTIONS (lb/size) 24=841/0-6-12, 15=506/0-6-12, 18=1678/0-5-8 6-0-0 oc bracing: 17-18,16-17. Max Grav24=865(LC 7), 15=568(LC 3), 18=1678(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 24-25=-102/0, 25-26=-102/0, 1-26=-102/0, 15-27=-102/0, 27-28=-102/0, 14-28=-102/0, 1-2=0/0, 2-3=-1975/0, 3-4=-1975/0, 4-5=-2183/0, 5-6=-1820/0, 6-7=-1820/0, 7-8=-1820/0, 8-9=01853, 9-10=0/853, 10-11=-929/24, 11-12=-929/24, 12-13=-929/24, 13-14=0/0 BOT CHORD 23-24=011234, 22-23=0/2183, 21-22=0/2183, 20-21=012183, 19-20=0/943, 18-19=01943, 17-18=-267/608, 16-17=-24/929, 15-16=0/735 ' WEBS 4-22=-109/71, 5-21=-46/118, 11-17=-337/0, 12-16=-130/67, 9-18=-294/0, 2-24=-1441/0, 2-23=0/864, 3-23=-264/6, 4-23=-413/42, 13-15=-858/0, 13-16=-104/244, 10-18=-1086/0, 10-17=0/618, 8-18=-1632/0, 8-20=0/1102, 6-20=-269/5, 5-20=-630/0 NOTES 1) Unbalanced floor live loads have been considered for this design. P) All plates are 3x4 MT20 unless otherwise indicated. ,S) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 19 and 7. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard -- -i - -..... _ Job i Truss Truss Type Qty ply Centex Homes, Model 1702 A I X07-458 I F03 FLOOR 8 1 1 _ _ _ Job Reference (optional ------- •-.-_ Paget- 0-1-8 _ Universal Forest Product, Inc. E359, Vero Beach, FI 32967 —' 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:43 2007 Page 1 0-1-8 i 2x3 1! 3x4 3x4 = 3x5 = 1 2 "16E 115 1-8-6 2-0-0 1-5-2 2x3 11 3x4 = 3x4 = 2x3 II 3x5 = 3 4 5 6 7 Ti Scale = 1:27.£ 3x4 II 8 1 W 2 W1 W W1 4 1 W 2 3x4 = 3x6 = 2x3 II 2x3 II 3x6 = 3x5 = 9-0-0 9-3-14 9-0-0 7-0-14 7,2-68-2-6 9-2-6 16-1-8 7-0-14 0-1-81-0-0 1-0-00-1-8 6-9-10 LOADING (psf) I SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TOLL 40.0 Plates Increase 1.00 TC 0.48 Vert(LL) -0.13 12-13 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.69 Vert(TL) -0.18 12-13 >999 240 BOLL 0.0 Rep Stress Incr YES WB 0.29 Hprz(TL) 0.04 9 n/a n/a BCDL 5.0 i Code FB,C2004/TP12002 (Matrix) Weight: 87 lb F LUMBER BRACING TOP CHORD 14 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 9=870/Mechanical, 14=870/0-6-12 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 14-15=-102/0, 15-16=-102/0, 1-16=-102/0, 8-9=-104/0, 1-2=0/0, 2-3=-1990/0, 3-4=-1990/0, 4-5=-2204/0, 5-6=-1997/0, 6-7=-1997/0, 7-8=0/0 BOT CHORD 13-14=011242, 12-13=0/2204, 11-12=0/2204, 10-11=0/2204, 9-10=011268 WEBS 4-12=-100/97, 5-11=-9811.15, 2-14=-1450/0, 2-13=01873, 3-13=-259/20, 4-13=-508/17, 7-9=-1470/0, 7-10=01852, 6-10=-243/42, 5-10=-523/25 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard ; Job I Truss - - Truss Type' Centex Homes, Model 1702 A t I X07-458 F04 FLOOR 8 1 :. i- - - - - --- - - ------ ---- Universal Forest Product, Inc. E359. Vero Beach, Fl. 32967 — — -- 6.500 s Job Reference (optionai-- Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:43 2007 Page 1 0-1-8 I 2-6-0 1-11-6 2-0-0 i- r ; i . ..._. _ ...---------- ----....---f- - ----------------{ I ------------_-----I I------- 1-8-2 ----I Scale = 1:19.51 3x4 = 2x3 II 2 3 2x3 11 3x4 = 4 5 3x4 II 6 W2 3 W W2 i 'I = 9 83x4 ;SX4 = 9-0-0 3x4 = 4-8-6 4-9-,14 5-9-14 1 6-9-14 6-1 1-6 11-4-8 4-8-6 0-1-8 1-0-0 1-0-0 0-1-8 4-5-2 3x5 - 9-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 1 Plates Increase 1.00 TC 0.41 Vert(LL) -0.09 9-10 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.39 Vert(TL) -0.15 9-10 >865 240 BCLL 0.0 I' Rep Stress Incr YES BCDL 5.0 I Code FBC2004/TP12002 WB 0.18 (Matrix) Horz(TL). 0.02 7 n/a n/a Weight: 60 lb ---111 - LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 7=608/Mechanical, 10=608/0-6-12 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 10-11=-104/0, 11-12=-104/0, 1-12=-104/0, 6-7=-110/0, 1-2=0/0, 2-3=-1077/0, 3-4=-1077/0, 4-5=-1077/0, 5-6=0/0 BOT CHORD 9-10=0/803, 8-9=0/1077, 7-8=0/819 WEBS 3-9=-202/0, 4-8=-227/0, 2-10=-937/0, 2-9=0/439, 5-7=-950/0, 5-8=0/448 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 s(rongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job ... .. ... ITruss Truss Type Oty Ply Centex Homes, Model 1702 A i X07-458 I F05 FLOOR 1 1 — ------------•---- — Job Reference o 6onal Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 — — - --- - -- — - — — � ---1 _. __..__. __ __..._ _.....__..... _... - ... . 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:44 2007 Page 1 i I-0-7-12 i Scale = 1:11.8I 3x4 II 3x4 = 1 2x3 11 2 3 3x4 = 4 3x4 11 7 10 °q I 9 9-0-0 3x4 = 3x5 9=0-0 6-4-12 LOADING (pso TCLL I SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP 40.0 TCDL 10.0 Plates Increase 1.00 TC 0.33 Vert(LL) -0.02 5-6 >999 480 MT20 244/190 BCLL 0.0 Lumber Increase 1,00 BC 0.21 Vert(TL) -0.03 5-6 >999 240 , Rep Stress Incr YES WB 0.08 Horz(TL) 0.00 5 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 39 lb LUMBER _ BRACING TOP CHORD 4 X 2 SYP No.2 BOT CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, WEBS 4 X 2 SYP No.2 BOT CHORD except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 5=335/Mechanical, 8=335/0-6-12 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 8-9=-115/0, 9-10=-115/0, 1-10=-115/0, 4-5=-11810, 1-2=0/0, 2-3=-367/0, 3-4=0/0 BOT CHORD. 7-8=0/367, 6-7=0/367, 5-6=0/367 WEBS 2-8=-426/0, 3-5=-423/0, 2-7=-50/94, 3-6=-55/88 NOTES 1) Unbalanced floor live loads, have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job Truss Truss Type Oty Ply nt - rCeex m Hoes, Model 1702 A X07-458 i F06 ( FLOOR 1 1 I :...... .- - - - . - ---- ----- - - - ---- - - — - - - ----J Job Reference�plLq". - -- -- -- Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:44 2007 Page 1 2-6-0 -12 j Scale = 1:13. 4x4 i l 44 = 1 4x4 i I 2 9 � 8 L 34x4 = 4x4 11 i 4 t W3 W4 W3 I -- 4x4 = 6 — 44 = 9-0-0 7-8-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d TCLL 40.0 Plates Increase 1.00 TC 0.29 Vert(LL) -0.01 6 >999 480 TCDL 10.0 Lumber Increase 1.00 BC 0.20 Vert(TL) -0.07 5-6 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.11 Horz(TL) 0.01 5 n/a n/a BCDL 5.0 Code FBC2004lTP12002 (Matrix) LUMBER TOP CH BRACING 4x6 = 9-0-0 PLATES GRIP MT20 2441190 Weight: 44 lb 4 X 2 SYP No.2 TOP' CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 5=406/Mechanical, 7=406/0-6-12 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 7-8=-10910, 8-9=-109/0, 1-9=-109/0, 4-5=-109/0, 1-2=0/0, 2-3=-494/0, 3-4=0/0 BOT CHORD 6-7=0/494, 5-6=0/471 WEBS 2-7=-573/0, 3-5=-546/0, 2-6=0/31, 3-6=0/29 NOTES 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard Job I Truss Truss Type Oty Ply Centex Homes, Model 1702 A X07 458 F07 I FLOOR 1 1 !_. ._. ..-....._ . - -� ._. _._...... - - J---------- --- - - ----- Job Reference o tional Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 -- 1-p---�------ 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Se 0-1-8 n 3x4 = 3x4 = 3x4 = 3x4 = 3x4 = 3x6 FP = 3x4 = 1 9-- 4BB 07 p 21 10:54:44 2007 Page 1 0 I}-8 Scale = 1:48.5i 3x4 3x4 = 3x4 = '+ 4.7 44 4:S 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 3x4 = 3x4 =3x6 FP= 3x4 = 3x5 = 9-0-0 27-10-8 0-1-S,Edge], [12:0-1-8,Edge], [14:0-1-8,Edge], [23:0-1-8,Edge], [24:0-1-8,Edge], [25:0-1-8,Edge], [37:0-1-8,Edge], [45:0-1-8,Edge], [47:0-1 3:0-1-8,0-1-81, [49:0-1-8 0-1-81 [50:0-1-8 0-1-81 1 50 49 LOADING s (p o SPACING 2-0-0 C51 DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.41 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a n1a 999 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(TL) -0.00 24 n/a n/a BCDL 5.0 Code FBC2004ITP12002 (Matrix) Weight: 145 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 46=220/27-10-8, 24=209/27-10-8, 45=581/27-10-8, 44=484/27-10-8, 43=512/27-10-8, 42=505/27-10-8, 41=507/27-10-8, 40=508/27-10-8, 39=501127-10-8, 38=455/27-10-8, 37=474/27-10-8, 25=565/27-10-8. 26=441/27-10-8, 27=522/27-10-8. 28=503/27-10-8, 29=508/27-10-8. 30=506/27-10-8, 31=507/27-10-8, 32=507/27-10-8, 33=369/27-10-8, 34=737/27-10-8, 36=328/27-10-8 FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 46-47=-215/0, 47-48=-215/0, 1-48=-215/0, 2449=-203/0, 49-50=-203/0, 23-50=-203/0, 1-2=-8/0, 2-3=-8/0, 34=-8/0 4-5=-8/0, 5-6=-8/0, 6-7=-8/0, 7-8=-8/0, 8-9=-8/0, 9-10=0/55, 10-11=0/55, 11-12=0/55, 12-13=0/122, 13-14=0/122, 14-15=0/6, 15-16=0/6, 16-17=0/6, 17-18=016, 18-19=0/6, 19-20=0/6, 20-21=0/6, 21-22=0/6, 22-23=0/6 BOT CHORD 45-46=010, 44-45=018, 43-44=0/8, 42-43=0/8, 41-42=018, 40-41=0/8, 39-40=0/8, 38-39=0/8, 37-38=018, 36-37=-55/0, 35-36=-55/0, 34-35=-55/0, 33-34=-6/0, 32-33=-6/0, 31-32=-6/0, 30-31=-6/0, 29-30=-6/0, 28-29=-6/0, 27-28=-6/0, 26-27=-6/0, 25-26=-6/0, 24-25=0/0 WEBS 2-45=-575/0, 3-44=472/0, 4-43=-499/0, 5-42=-492/0, 6-41=-493/0, 7-40=-495/0, 8-39=488/0, 9-38=441/0, 11-37=-391/0, 22-25=-543/0, 21-26=-430/0, 20-27=-50810, 19-28=-490/0, 18-29=-494/0, 17-30=-493/0, 16-3 1 =-494/0, 15-32=-493/0, 14-33=-356/0, 13-34=-510/0, 1-45=0/12, 23-25=-9/0, 9-37=-96/0, 1434=-177/0, 12-36=-318/0, 12-34=-103/0 NOTES 1) All plates are 2x3 MT20 unless otherwise indicated. 2) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 10 and 35. 3) Gable requires continuous bottom chord bearing. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 24-46=-10, 1-23=-370(F=-270) Job I r-u-S. s Truss Type pty Ply— Centex Homes, Model 1702 A X07-458 FG1 FLOOR 3 Job Reference (optiopall .. ...... ... 0�niversai orest Product, Inc. E359, Vero Beach, Fl. 32967 6.500 s Feb 52007 MiTek Industries, Inc. Fri Sep 21 10:54:45 2007 Page 2-0-6 4 Scale = 1:28.6i 16-1-4 5x6 = 2x3 11 3x4 = 3x7 = 5x16 3x7 1 5X16 2 3 4 5 6 7 Ci 2 4 5 W 9 _j --BT- 5x7 13 12 11 ' 3-11-5 10 9 4N6 4-1-73X7 - 3-11-5 _84= 3x7 4-1-5___-4�6 9-0-0 9-0-0 17-0-4 17-0-4 Plate Offsets (X,Y): [1:0-7-12.0-2-8], [2:0-1-12,0-1-8], [3:0-3-0,0-3-4], [6:0-1-12,0-1-8], [7:0-7-12.0-2-8], [9:0-1-12.0-2-8], [10:0-1 -12,0-1 -8], [11 :0-4-0,0-4-12], [1 —20-1--f-2-'l .0-1-81,[13:0-1-12.0-2-81 LOADING (psf)� SPACING 2-0-0 CS1 DEFL in (loc) I/defl L/d PLATES TCLL 40.0 Plates Increase 1.00 TC 0.75 GRIP Vert(LL) -0.31 11 >624 480 MT20 TCDL 110.0 Lumber Increase 1.00 BC 0.80 Vert(TQ -0.48 11 >400 240 244/190 PCLL 0.0 Rep Stress Incr NO VVB 0.99 Horz(TL) 0.05 8 n/a n1a BCDL 5.0 1--_ - --- Code FBC20041TP12002 (Matrix) - Weight: 307 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 TOP CHORD Structural wood sheathing directly applied or 4-2-2 oc purlins. DOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 *Except* W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W1 2 X 6 SYP SS W1 2 X 6 SYP SS REACTIONS (lb/size) 8=6836/0-3-8, 14=6836/0-8-0 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-1 1517/0, 2-3=-18376/0, 3-4=-20586/0, 4-5=-20586/0, 5-6=-18405/0, 6-7=-11515/0 BOT CHORD 13-14=-010, 12-13=0111517, 11-12=0118504, 10-11=0/18405.9-10=0/11515,8-9=0/0 WEBS 1-14=-5813/0, 7-8=-5811/0, 4-11=-187/0, 2-13=-3604/0,3-12=-1324/0. 5-10=-131510, 6-9=-3615/0, 2-12=0n639, 3-11=0/2316,5-11=0/2404,6-10=017674, 7-9=0/12823,1-13=0/12825 NOTES 1) 3-ply truss to be connected together with 1 Od (0. 13 1 "x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-4-0 oc. Webs connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc. .2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section, . Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 8-14=-749(F=-739), 1-7=-100 Job Truss Truss Type Cent ex �te Ply x Homes, Model 1702 A . . ...... X07-458 FG2 FLOOR ] Job Reference (optional) Universal Forest rodu'ct. Inc. E359, Vero Beach, Fl. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:45 2007 Page 2-7-6 2-8- 4 10- 2-11-122-4-8 2-11-12 1�140 2-8-14 Scale: 1/4"=11 I 3x6 3x4 X7 = 5.5 = 3x7 = 3"- 7-93_"-:T 3X6 I 24 25 5 6 7 8 9 10 T1 _____T_1 9 '0 U 23 22 21 20 19 18 17 16 15 14 13 12 2x5 it 3x4 = 4x6 = 5x8 = 3x4 = 2x5 I! 27-7-8 9-0-0 9-0-0 9-0-0 16-8-4 27-10-8 16-8-4 11-2-4 Plate Offsets (X,Y): [3:0-2-4,0-1-8], [4:0-2-4,0-1-8], [5:0-3-0,0-1-8], [6:0-2-8,0-3-0], [7:0-3-0,0-1-8], [8:0-2-4,0-1-8], [9:0-2-4,0-1-8], (13:0-1-12,0-1-8),(14:0-2-4,0--1-81. f1 5:0-240-1-8L.-L1 6-.0-2-4,0-1-81, [17:0-4-0,0-2-41, [19:0-2-4,011-8],1?2�0�-2-40-1 -�B ' f21:0-2-4,0-1-81, f22:0-1-12,0-1-81 LOADING (psg SPACING 2-0-0 CS1 DEFIL in (loc) I/defl L/d PLATES TCLL 40.0 Plates Increase 1.00 TC 0.39 Vert(LL) -0.07 20 >999 480 MT20 GRIP 244/190 1 TCDL 10.*0 Lumber Increase 1.00 BC 0.21 Vert(TL) -0.11 20 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.41 Hc)rz(TL) 0.01 12 n/a n/a BCDL 5 Code FBC2004ITP12002 (Matrix) Weight: 328 lb LUMBER BRACING TOP CHORD 2X4SYP SS TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. :BOTCHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2 X 4 SYP No.2 *Except* W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W1 2 X 6 SYP SS W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W1 2 X 6 SYP SS W1 2 X 6 SYP SS, W1 2 X 6 SYP SS REACTIONS (lb/size) 23=1 03210-6-12, 16=4423/0-5-8, 12=48410-6-12 Max Grav 23=1 068(LC 2), 16=4423(LC 1), 12=695(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-2090/0, 2-3=-3290/0, 3-4=-3291/0, 4-24=-2496/0, 24-25=-2496/0, 5-25=-2496/0, 5-6=-4211709, 6-7=-421t709, 7-8=0/3049, 8-9=-14761711, 9-10=-1664/260, 10-1 1=-1238/36 BOT CHORD 22-23=0/0, 21-22=0/2090, 20-21=0/3290, 19-20=0/3291, 18-19=012496, 17-18=0/2496, 16-17=-304910, 15-16=-711/1476, 14-15=-260/1664, 13-14=-36/1238, 12-13=0/0 WEBS 3-21=-175/160, 9-14=01390, 5-19=0/530.7-16=-2563/0, 8-15=0/763, 4-20=0/310, 2-22=-857/0, 10-13=-539/25, 2-21=011299, 3-20=-427/113, 4-19=-1255/0, 10-14=-242/460, 9-15=-717/0, 8-16=-349410, 6-17=-806/0, 5-17=-2421/0.7-17=0/3557, 1-23=-1026/0, 1-22=0/2277, 11-12=-655/0, 11-13=-39/1349 -NOTES 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) All plates are 3x5 MT20 unless otherwise indicated. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 406 lb down at 6-5-8, and 757 lb down at 20-1-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 12-23=-10, 1-5=-100, 5-8=-300(F=-200), 8-11=-100 continued on_RaAe 2 Job...- Truss.. - --- -- ---- Truss Type ' X07-458 I FG2 FLOOR i_ _..... __.._. _ IL- — -- ------ ----- Universal Forest Product, nc. E359, Vero Beach, FI. 32967 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 21=-406(F) 15=-757(F) ---- - --- Oty -C ----- ---- -- --02 A --- Centex Homes,- Model 17 1 Job Reference (optional 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:45 2007 Page 2 _. _..- --- - -- ----....... --- --- - --- — -- - - -en --- -- . Model 170 Job iYruss Truss Type Qty Ply Centex Homes, Model 1702 A i ! X07A58 FG3 FLOOR 1 1 l Job Reference.LPtional - _ Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:46 2007 Page 1 1 r 1 4x6 -= 2 4x4 1! Scale = 1: 3-4-8 LOADING (psf) I SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.29 Vert(LL) -0.01 3-4 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.16 Vert(TL) -0.01 3-4 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 21 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-8 oc purlins, BOT CHORD 2 X 6 SYP SS except end verticals. WEBS 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. W12X6SYP SS REACTIONS (lb/size) 4=320/Mechanical, 3=334/Mechanical FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-4=-150/0, 2-3=-150/0, 1-2=0/0 BOT CHORD 4-5=-0/0, 3-5=-0/0 WEBS 1-3=0/0 NOTES 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 325 lb down at 1-9-8 on bottom chard. The design/selection of such connection device(s) is the responsibility of others. 4) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). -LOAD CASE(S) Standard '1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 3-4=-10, 1-2=-100 Concentrated Loads (lb) Vert: 5=-325(B) Job it. Truss Type r074-58 FG4 (FLOOR Universal Forest Product, Inc. E359, Vero Beach, FI.32967 1 4x6 = LOADING (psf) I SPACING 2-0-0 TCLL 40.0 Plates Increase 1.00 TCDL 10.0 Lumber Increase 1.00 BCLL 0.0 Rep Stress Incr NO BCDL 5.0 Code FBC2004ITP12002 LUMBER TOP CHORD 2 X 4'SYP N0.2 SOT CHORD 2 X 6 SYP SS WEBS 2 X 4'SYP No.2 *Except* W12X6SYPSS REACTIONS (lb/size) 4=35510-1-8, 3=37 1 /Mechanical FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-4=-150/0, 2-3=-150/0, 1-2=0/0 BOT CHORD 4-5=-0/0, 3-5=-0/0 WEBS 1-3=0/0 2-7-8 3-4-8 Oty Ply Centex Homes, Model 1702 A ' 1 1 i Job Referencelo tiionalZ.. — 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:46 2007 Page 1 2 4x4 11 Scale = 1:8.4j I CSI DEFL in (loc) I/deft L/d PLATES GRIP TC 0.29 Vert(LL) -0.01 3-4 >999 480 MT20 244/190 BC 0.19 Vert(TL) -0.01 3-4 >999 240 WB 0.00 Horz(TL) -0.00 3 n/a n/a (Matrix) Weight: 21 lb BRACING TOP CHORD Structural wood sheathing directly applied or 3-4-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES 1) Refer to girder(s) for truss to truss connections. 2) Provide mechanical connection (by others) of truss to bearing plate atjoint(s) 4. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 396 lb down at 1-9-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). GOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 3-4=-10, 1-2=-100 Concentrated Loads (lb) Vert: 5=-396(F) gob Truss `- - - - - - --- -- Truss Type Qty Ply Centex Homes, Model 1702 A X07-458 iFG5 FLOOR 1 --: . _..._....._ _.... - �._._._ -..- --- - - -- -- __ _ Job Reference Lop6onal _..--- - - - -- Universal Forest Product, Inc. E359, Vero Beach,, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:46 2007 Page 1 1-3-0 . , � I I I Scale: 1 /4"=11 I I 4x4 II 7x10 = 5x7 = 4x4 = 8x8 = 4x4 = 4x4 = 4x4 II 1 2 3 4 27 5 6 7 8 9 28 10 11 12 13 �--- ----�i ----- - ---T2- - 2-- 2-- 2- _ -- - ---- -63- 25 24 23 2622 21 20 19 18 17 29 16 15 14 i 8x8 _ 8x16 = 5x8 = 4x4 = 4x4 = 8x8 = 4x4 = 9-0-0 9-0-0 i 9-0-0 I _ 6-10-3 6-1p-8 27-7-8 (� 6-10-3 0-0-5 20-9-0 E Plate Offsets (X,Y)_[5:0 4-12 0-5-019:0-4-0 0-4-81, r17:0-4-0 0-5-4 20:0-2-8,0-2-01, r22:0-6-8,Edge] r25:0-4-0,0-5-01-- I LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ltd PLATES GRIP I TCLL 40.0 Plates Increase 1.00 TC 0.90 Vert(LL) -0.28 17-18 >884 480 MT20 TCDL 10.0 244/190 Lumber Increase 1.00 BC 0.71 Vert(TL) -0.43 17-18 >571 240 BCLL 0.0 Rep Stress Incr NO WB 0.66 Horz(TL) 0.04 14 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 360 lb LU BEM R BRACING TOP CHORD 2 X 6 SYP SS TOP CHORD Structural wood sheathing directly applied or 4-8-1 cc purlins, BOT CHORD 2 X 6 SYP SS except end verticals. WEBS 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 4-5-11 cc bracing. I W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W4 2 X 6 SYP SS REACTIONS (lb/size) 14=3506/0-5-4, 25=-1481/0-5-4, 22=9797/0-3-8 Max Uplift25=-2280(LC 3) Max Grav 14=3521 (LC 3), 25=325(LC 2), 22=9797(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-25=-204/254, 13-14=-590/0, 1-2=-25/420, 2-3=0/5179, 3-4=0/10424, 4-27=0/12897, 5-27=0/12897, 5-6=0/3189, 6-7=-4749/0, 7-8=-9819/0, 8-9=-12575/0, 9-28=-12979/0, 10-28=-12979/0, 10-11=-10681/0, 11-12=-6335/0, 12-13=-591/0 BOT CHORD 24-25=-2713/150, 23-24=-7865/0, 23-26=-12897/0, 22-26=-12897/0, 21-22=-7311/0, 20-21=011540, 19-20=0/7861, 18-19=0/11797, 17-18=0/13369, 17-29=0/12282, 16-29=0/12282, 15-16=0/8972, 14-15=0/3894 WEBS 2-25=-162/2961, 2-24=-3430/0, 3-24=013736, 3-23=-4331/0, 4-22=-4134/0, 4-23=0/3837, 12-14=-4266/0, 12-15=0/3395, 11-15=-3668/0, 11-16=012377, 10-16=-2227/0, 10-17=0/968, 9-17=-542/70, 9-18=-1124/0, 8-18=0/1103, 8-19=-2773/0, 7-19=0/2744, 7-20=-4346/0, 6-20=014488, 6-21=-6301/0, 5-21=0/5735, 5-22=-7239/0 NOTES ,1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: • Top chords connected as follows: 2 X 6 - 2 rows at 0-9-0 cc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 cc. Webs connected as follows: 2 X 4 -1 row at 0-9-0 cc, 2 X 6 - 2 rows at 0-9-0 cc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been to distribute loads provided only noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) All plates are 46 MT20 unless otherwise indicated. 5) Bearing at joint(s) 22 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2280 lb uplift at joint 25. 7) Uplift for first LC exceeds limits 8) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 9) CAUTION, Do not erect truss backwards. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 310 lb down at 6-4-0, and 345 lb down at 20-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard :ontinued on page 2 Job ?Truss Truss Type iX07-458 FG5 LOOR Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967 Oty Ply Centex Homes. Model 1702 A 6.500 s Feb 6 2007 MiTek Industries, Inc. Fri Sep 21 10:54:46 2007 Page 2 I i LOAD CASE(S) Standard 1) Floor: Lumber Increasez1.00, Plate Increase=1.00 Uniform Loads (pIq ert: 14-25=-10, 1-27=-340(F=-2410), 27-28=-470(F=-370), 13-28=-340(F=-240) Concentrated Loads (lb) Vert: 26=-310(B) 29=-345(B) Job Truss iTruss Type I I X07-458 HJ2 MONO TRUSS Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 I Oty Ply rCentex Homes. Model 1702 A 2 1 _ Job Reference (optional) 6.500 s FgtA_ 7Q07 MiTek Industries, Inc. Fri Sep 21 10 54:47 2007 Page 1 -1-b-o 2-9-15 18-8-0 4x6 II 1-10-11 0-11-4 Plate Offsets (X,Y) —� [2:0-3-10J d e1, (2:0-1-5,1-5-3] LOADING (pso SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.22 Vert(LL) -0.00 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.04 Vert(TL) -0.00 2-4 >999 180 BCLL . 10.0 1 BCDL 10.0— I Rep Stress Incr NO Code WB 0.00 Horz(TL) -0.00 3 n/a n/a I _1 FBC2004/TP12002 (Matrix) - Weight: 12 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-9-15 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 3=46/Mechanical, 2=269/0-6-7, 4=20/Mechanical Max Horz 2=66(LC 3) Max Uplift3=-15(LC 4), 2=-162(LC 3) Max Grav3=46(LC 1), 2=269(LC 1), 4=40(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/28, 2-5=-41/0, 3-5=-6/9 3OT CHORD 2-6=0/0, 4-6=0/0 VOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. ?) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 1) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 15 lb uplift at joint 3 and 162 lb uplift at joint 2. i) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 32 lb down at 1-5-12 on top chord, and 21 lb up at 1-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. i) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). .OAD CASES) Standard Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 2-4=-20 Concentrated Loads (lb) Vert: 6=10(F) iJob Truss ' ---.-- i I Truss Type Qty ply Centex Homes, Model 1702 A X07-458 HJ7U 1 MONO TRUSS 4 1 L.-.._ _— . _....-... _ .._.. _l._. ___. _ __ _ _ _ _ ____ Jo_b Reference (optional L . -- - -- .2 1.11.. I Universal Forest Product, Inc 3 Vero Beach, FI.332967 - 1 i y�_�� 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:47 2007 1��-b 1 8-5-13 1-5-0 4-4-4 4-1-9 Scale = 1:16.51 c� d 21-1-11 18-8-0 18-8-0 8-5-0 8-$,13 4-4-4 4-0-12 0-0-13 LOADING (pso TCLL 20.0 TCDL 15.0 BCLL 10.0 BCDL 10.0 I SPACING 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr NO Code FBC2004ITP12002 CSI TC 0.38 BC 0.25 WB 0.20 (Matrix) I DEFL in Vert(LL) -0.01 Vert(TL) -0.04 Horz(TL) 0.01 (loc) I/deft L/d 7 >999 360 6-7 >999 180 6 n/a n/a PLATES GRIP MT20 244/190 Weight: 36 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) '4=226/Mechanical, 2=400/0-5-11, 6=294/Mechanical Max Horz2=150(LC 3) Max Uplift4=-138(LC 3). 2=-182(LC 3), 6=-61(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/28, 2-3=-731/146, 3-4=-66147 BOT CHORD 2-7=-244/681, 6-7=-244/681, 5-6=0/0 WEBS 3-7=0/198, 3-6=-716/256 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf,, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.O psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 138 lb uplift at joint 4, 182 lb uplift at joint 2 and 61 lb uplift at joint 6. -8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pif) Vert: 1-2=-70 Trapezoidal Loads (plf) Vert: 2=-4(F=33, B=33)-to-4=-148(F=-39, 6=-39), 2=-0(F=10, B=10)-to-5=-42(F=-11, B=-11) Trus-._-__.._... _.._. _.. Job !s I ' 1 X07-456 I K5 i Unige&al Forest Product, Inc. E359, Vero Beach, r Truss Type Qty Ply Centex Homes, Model 1702 A i JACK 1 1 Job Reference(optional- 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:47 2007 Pia I - - - -- - - -- - ---- 5-5-0 - --- --- --------- -- - -- - 4x4 = 9-11-141 9-0-0 9-0-0 5-5-0 LOADING (psf) I SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.34 Vert(LL) -0.03 1-3 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.23 Vert(TL) -0.07 1-3 >868 180 BCLL 10.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 2 n/a nla BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 16 Ito LUMBER TOP BRACING CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-5-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=115/0-8-8, 2=164/Mechanical, 3=47/Mechanical Max Horz 1=32(LC 3) Max Upliftl=-33(LC 3), 2=-89(LC 3) Max Grav1=115(LC 1). 2=164(LC 1), 3=97(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-23/23 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category If; Exp B; enclosed; MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s)-for truss to truss connections. ,4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 33 lb uplift at joint 1 and 89 lb uplift at joint 2. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Trapezoidal Loads (pll) Vert: 1=-6(F=32, B=32)-to-2=-95(F=-12, B=-12), 1=-2(F=9, B=9)-to-3=-27(F=-4, B=4) i Job itruss X07458 - I K9 j Universal Forest Product, Inc,, � Vero E -1-5-0 1-5-0 -- - Truss TYpe MONO TRUSS 5-2-12 Oty Ply Centex Homes, Model 1702 A 2 1 _ Job Reference o tional 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:47 2007 P5.9y01 3-2-5 Scale = 1:16.� 9-0-0 10-5-15 9-0-0 5-2-12 8-4-6 8-n51-1 5-2-12 3-1-10 0-0-11 LOADING (pso SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase I 1.25 TC 0.23 Vert(LL) -0.02 2-7 >999 360 MT20 244/190 TCDL 15.0 I Lumber Increase 1.25 BC 0.28 Vert(TL) -0.07 2-7 >999 180 BCLL 10.0 I Rep Stress Incr NO WB 0.16 Horz(TL) 0.01 6 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 33 lb 1 LUMBER TOP CHORD X BRACING 2 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP N0.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 4=177/Mechanical, 2=386/0-10-10, 6=334/Mechanical Max Horz 2=87(LC 3) Max Uplift4=-98(LC 3), 2=-192(LC 3), 6=-76(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-8=0/13, 2-8=0/13, 2-3=-908/226, 3-4=-35/23 BOT CHORD 2-7=-279/874, 6-7=-279/874, 5-6=0/0 WEBS 3-7=0/201, 3-6=-915/292 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 44 MT20 unless otherwise indicated. 4)'Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 98 lb uplift at joint 4, 192 lb uplift at joint 2 and 76 lb uplift at joint 6. •6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert:1-8=-70 - Trapezoidal Loads (plf) Vert: 8=0(F=35, B=35)-to-4=-147(F=-39, B=-39), 2=-2(F=9, B=9)-to-5=-42(F=-11, B=-11) i tiru—ss— Truss Type aty Ply Centex Homes, Model 1702 A iX07458 ivio GABLE 1 1 — — ------- Job Reference orlal n w-11 Forest Product, Inc. E359, Vero, Beach, Fl. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:46-�!JoO* -l5a-'g'e -i 1 Scale = 1: 17.4: 4 3.00 F1-2 3 T1 W1 • CN ST2 ST1 B1 'x X, 'X X "K > 9-4-7 10-8-8 10-8-8 �i-1ateOff—se—ts--(—X—,Y): —[5:Edge.,0-3-81 LOADING (psf SPACING 2-0-0 CS1 DEFIL in (loc) I/clefl L/d PLATES GRIP TCLL 20.0 I Plates Increase 1.25 TC 0.33 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15.0 I Lumber Increase 1.25 BC 0.22 Vert(TL) n/a n/a 999 BOLL 10.0 Rep Stress Incr YES WB 0.04 Horz(TL) 0.00 5 n/a n/a BCDL 10.0 Code FBC2004fTP12002 (Matrix) Weight: 38 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2 X 4 SYP No.2 except end verticals. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=204110-8-8,5=115/10-8-8,6=-12/10-8-8,7=537110-8-8 Max Horz 1=105(LC 3) Max Upliftl=-49(LC 3),5=-44(LC 3),6=-12(LC 1), 7=-199(LC 3) Max Grav1=204(LC 1), 5=1 15(LC 1), 6=7(LC 3),7=537(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-77137, 2-3=-55/0, 3-4=-22/6, 4-5=-8 1 /46 BOT CHORD 1-7=-6114,6-7=-6114,5-6=-6/14 WEBS 3-6=-17/17, 2-7=-380/201 NOTES '11) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf,, Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. -5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 49 lb uplift at joint 1, 44 lb uplift at joint 5, 12 lb uplift at joint 6 and 199 lb uplift at joint 7. LOAD CASE(S) Standard ;Job ----- _..... iX07-458 jV2 ( UniveriT'4prest Product, Inc. E359, i 11 VALLEY 2-8-8 2-8-8 Qty Centex Home; F 1 1 _ Job Reference 6.500 s Feb 5 2007 MiTek )2 A i Inc. Fri Sep 21 10:54:48 2007 Page 1 I — 2-8-8 2-8-8 4x4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 I Plates Increase 1.25 TC 0.03 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) n/a n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 I 1— Code FBC2004ITP12002 (Matrix) Weight: 6lb LUMBER TO. BRACING CHORD 2 X 4 SYP 1,10.2 TOP CHORD Structural wood sheathing directly applied or 2-8-8 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=6112-8-8, 2=47/2-8-8, 3=1412-8-8 Max Horz 1=17(LC 3) `Max Upliftl=-18(LC 3), 2=-27(LC 3) 'Max Grav 1=61(LC 1), 2=47(LC 1), 3=27(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-10/10 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-sec6nd gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category It: Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Gable requires continuous bottom chord bearing. 4) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 18 lb uplift atjoint 1 and 27 lb uplift at joint 2. LOAD CASE(S) Standard - .. ----- ; Job ;Truss runs .-- _— — Truss Type X07-458 IV2A VALLEY --- ---- ----...._ Uni�er/sal Forest Product, Inc. E3- 59, Vero Beach, FI.32967 i Qty� Ply Centex Homes, Model 1702 A ; 1 1 j Job Reference (o�tlonal)—._—_._- _ 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:48 200,7 Page 1 2-11-8 LOADING (ps6 i SPACING 2-0-0 CSI 2-11-8 4x4 = DEFL in floc) I/deft Ud TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) n/a n/a 999 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) n/a n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) iLUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 REACTIONS (lb/size) 1=67/2-11-8, 2=52/2-11-8, 3=15/2-11-8 Max Horz 1=20(LC 3) Max Upliftl=-20(LC 3), 2=-30(LC 3) 'Max Grav1=67(LC 1). 2=52(LC 1), 3=30(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-12/12 BOT CHORD 1-3=0/0 PLATES GRIP MT20 244/190 Weight: 7 lb BRACING TOP CHORD Structural wood sheathing directly applied or 2-11-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Gable requires continuous bottom chord bearing. 4) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint 1 and 30 lb uplift at joint 2. -1 LOAD CASE(S) Standard Job'--._...._. ... __._--- ' truss... _.---------._ ----------•------------ Truss T e ------------------------- ----- -- .—....--- — -- . . YP 0ty Ply Centex Homes, Model 1702 A X07-458 i V4 VALLEY 1 1 .-. __ _-_ , _ _-,._ — Job Reference o tional i U i e orest Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc, Fri Sep 21 10:54:48 2007 Page 1 i I i - 488 II Sgale = 1:7.61 10-10-7 LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 10.0 Rep Stress Incr YES BCDL 10.0 Code FBC2004ITP12002 LUMBER TOP CHORD 2 X 4 SYP N0.2 BOT CHORD 2 X 4 SYP N0.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=152/4-8-8, 3=152/4-8-8 Max Horz 1=38(LC 3) Max Upliftl=-47(LC 3), 3=-56(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-23/23, 2-3=-118/66 BOT CHORD 1-3=0/0 4-8-8 CSI DEFL in (loc) I/deft L/d PLATES GRIP TC 0.18 Vert(LL) n/a n/a 999 MT20 244/190 BC 0.11 Vert(TL) n/a n/a 999 WB 0.00 Horz(TL) 0.00 n/a n/a (Matrix) Weight: 13 lb BRACING TOP CHORD Structural wood sheathing directly applied or 4-8-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 1 and 56 lb uplift at joint 3. LOAD CASE(S) Standard Job. Truss Type X07-458 JV6 VALLEY Fbnjjir�Forest Product, Inc. _4 , ero '5fy--'*---Fc-e-n-t-e-x'Homes, "Model '1-702-A 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:48 2007 Page I 6-8-8 Scale = 1: 10 3.00 FI-2 2 T1 W11 B1 X 'I X 'N XX >,X.� .\, INA, X X X X 10-4-7 6-8-8 6-8-8 Plate 0 3: Ed e 0-3-8 LOADING (pso SPACING 2-0-0 CS1 TCLL 20.0 Plates Increase 1.25 DEFIL in (loc) I/clefi L/d PLATES GRIP TC 0.46 TCIDL 15.0 I Lumber increase 1.25 BC 0.27 Vert(LL) n/a n/a 999 MT20 244/190 Vert(TL) n/a n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 I Code FBC2004/TP[2002 (Matrix) Horz(TL) 0.00 n/a n/a Weight: 20 lb LUMBER TOP CHORD 2 X 4 SYP No.2 BRACING — BOT CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-8-8 oc pudins, WEBS 2 X 4 SYP No.2 except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=242/6-8-8,3=242/6-8-8 Max Horz 1=60(LC 3) Max U pliftl =-74(LC 3), 3=-89(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-37137,2-3=-188/105 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf, Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) .*This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 74 lb uplift at joint 1 and 89 lb uplift atjoint3. LOAD CASE(S) Standard Job ! Truss _- --- - Truss Type - ---- — -- - `-`--—"--"'- Qty'- pjy" Centex Homes, Model 1702 A X07-458 IV8 VALLEY 1 1 1 Job Reference Una �r�aj Forest Product, Inc E359, Vero Beach, FI. 32967 ,----- — 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Sep 21 10:54:49 2007 Page 1 I i 8-8-8 9-10-7 LOADING (psf) I SPACING 2-0-0 TCLL 20.0 Plates increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL •10.0 Rep Stress Incr YES BCDL 10.0 Code FBC2004/TP12002 LUMBER TOP CHORD 2 X 4 SYP N0.2 BOT CHORD 2 X 4 SYP N0.2 WEBS 2 X 4 SYP No.2 Scale = 1:14.1 8-8-8 CSI I DEFL in floc) I/defl Ud PLATES GRIP TC 0.23 Vert(LL) n/a n/a 999 MT20 2441190 BC 0.14 Vert(TL) n/a n/a 999 WB 0.03 Horz(TL) 0.00 n/a n/a (Matrix) Weight: 28 lb BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=150/8-8-8, 4=93/8-8-8, 5=421/8-8-8 Max Horz 1=83(LC 3) Max Upliftl=-35(LC 3), 4=-34(LC 3), 5=-155(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-69/43, 2-3=-37/12, 3-4=-73/41 BOT CHORD 1-5=0/0, 4-5=0/0 WEBS 2-5=-327/183 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; • cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise indicated. 4) Gablerequires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 35 lb uplift at joint 1, 34 lb uplift at joint 4 and 155 lb uplift at joint 5. LOAD CASE(S) Standard