Loading...
HomeMy WebLinkAboutModel 5240 BL_7-1-98-599(210)F_ 0 PRELIMINARY NOT FOR CONSTRUCTION FINAL PLANNED UNIT DEVELOPMENT APPROVED DATE y + ( 7 ? " BOARD OF COUNTY COMMISSION 9 Chairman 101 Final PUD Approval for Parcel #18 (Clubside) @ the Reserve (PUD II) FOR CONSTRUCTION January 28, 1997 - 23:18 C:\ACAD\ACAD.DWG - TRL 4RE14 C14LCULAT I ON LIVING AREA A/C 2060 SF 1 5T FLOOR 2060 SF 2 ND FLOOR 0 5F GARAGE 423 5F COVERED ENTRY 61 5F COVERED PATIO 20(o SF TOTAL AREA 2750 SF NOTED 1. ALL WINDOWS AND SLIDING DOOR GLASS 51-1ALL BE PER ENERGY CALC5. 2. PROVIDE 120 5Q.IN. OF SCREENED BLOCK VENT AT BLOCK WALL IN GARAGE AT FLOOR LEVEL. 3. DRYER MUST VENT TO OUTSIDE. 4. SET HOTWATER HEATER AT FIN. FLR. LEVEL 5. ALL MECHANICAL FANS MUST BE VENTED TO OUTSIDE. 6. ALL BATH ROOM FLOOR AND BASE SHALL BE IMPERVIOUS MATERIAL WHERE REQUIRED BY LOCAL BUILDING CODE. "I. HVAC CONTRACTOR TO PROVIDE ELECTRICAL BREAKERS IN AIR HANDLER 8. ALL BATHROOM FIXTURE OUTLETS TO BE 80" AFF OR AS PER BUILDER SPECIFICATIONS. 5. PROVIDE RECEPTACAL FOR MICRO/HOOD FAN 65" AFF. CENTER RANGE SPACE. 10. SMOKE DETECTORS SHALL BE HARD WIRE 110V W/ BATTERY BACK UP. MULTIPLE DETECTORS SHALL BE INTERCONNECTED. 11. ALL WATER CLOSETS, LAVATORY, 6HOWERI-IEAD5, URINALS AND SINKS COMPLY WITH TABLE 46-R2 OF SP.C. 1994 EDITION PROVIDE THRESHOLD A WEATHER5TRIPPING • ALL EXTERIOR DOOR5. PROVIDED TEMPERED GLA55 a ALL OPENINGS W/ IN 12" OF ALL DOOR5 4 AT ALL TUB 4 5HOLLIER ENCLOSURES ALL WINDOWS 5HALL MEET EGRESS, LIGHT 4 VENTILATION REQUIREMENT5. ALL BATPRM. FLR5 4 5A5E SHALL BE TILE OR OTHER IMPERVIOUS MATERIAL ALL INT. NON-BR'G WALL SHALL BE MTL. 5TUD5 W/ 1/2" G WB. EA SIDE ALL WATER CLOSETS SHALL HAVE 15" MIN CLEAR FROM THE CENTER LINE OF FIXTURE TO ANY FINISHED SURFACE. FLOOR PLANA5BREVIATION5: AGU AIR COMPRESSOR UNIT AHU AIR HANDLING UNIT DIA. DIAMETER F.C. FILLED CELL H.B. NOSE BIB F.M. FIELD MEA65URE HWH HOT WATER HEATER S.C. SELF- CL05ING MIN. MINIMUM OPT. OPTIONAL T.F. TIGHT FITTING P.T. PRESSURE TREATED SH. 5HELVE5 5L. GL. DR 5LIDING GLASS DOOR 5Q. FT. SQUARE FEET T.G. TIE COLUMN TEMP, TEMPERED GLA55 UTIL. UTILITY W/ WITH REFER TO ELEVATIONS FOR ALL TRANSOM GLASS 51ZE5 AND LOGATION5. NOTE : WINDOWS MARKED EGRESS SHALL COMPLY WITH THE REQUIREMENTS OF THE SOUTHERN BLDG CODE SECTION FOR SECOND MEANS OF ESCAPE. CLEAR OPENING OF EGRESS WINDOW SHALL NOT BE LE55 THAN 20" IN WIDTH, NOR LE55 THAN 24" IN HEIGHT, AND SHALL BE A MINIMUM TOTAL OF 5.1 SQUARE FEET IN CLEAR AREA. FOR PERMIT W."ON iODEL 57240 BL ISSUE DATE: JULY 1, 1998 REVISIONS DATE. JOB NO: W Z >111!: =) w 0 � U LU W W= � 3:.j Ice � O 0 J LLM F- O m or .0 , Z/O) A-2 04 rr Ln 0o w CD m m m m 0 cli co CO m i J 0 `1 co F_ F`EE,4% Fz L Fz \vl,4 T I C:DN SCALE: 1/'4 " = 1' - 0)" FINAL PLANNED UNIT DEVELOPMENT APPROVED Q' DATE OARD OF COUNTY COMMISSION 9- Nai.. ,4 Chairman 12 SPANISH 'S' TILE ROOF Wl 5.5:12 PITCH TYP. — — — — — — — — — — — — — — — — — 2"X 10" ROS CEDAR WOOD FASCIA TYP. TEXTURED STUCCO FIN. ❑ ❑ TYP. 1/2"RASIED SMOOTH [1:11 MEI IDJ FFEI STUTU D CCO BANS TYP.M IEJ PRECAST OR FOAM SILL TYPICAL 0 ------------ q- F-1 I oD - oN T 5C;"L E:: I 12 5.5 ELE%/"TIoN a E -------------------------------------------------------------------------------- pRELIMINAR u CTION NOT FOR CONSTR Final PUD Approval for Parcel #18 (Clubside) @ the Reserve (PUD II) 1/-4 " = I' - CO)" LEEFT 51E:)E ELE\,/,4T1C N &GALE: 1/4 " = I' - 10" ELEv 2m'e" ELEv W-I" ELEv Im'-I" ELEv 8'-I" DECRO FOAM COL ELEv m" ISSUE DATE. JULY 7, 1998 REVISIONS DATE: JOB NO: Q N z WZ O � � Q NOV W �W W V =J 0 N W 60 W Y J m NT SIDE E L E %/ATION I/MODEL 5240 BL SCALE: 4 I' - 0" C N r' 01 00 rr C> O Ln J U_ 00 r f/J n Q 10 !O v W Z O EIiZ M 9 t� V woo O r o J y3 Z Lu z m Z Z O C3 9? O Ln o, a a FOR PERM8TFOR CONSTRUCTIN A-3 12 5.5F SPANISH 'S' TILE ROOF W1 5.5:12 PITCH Tl'P, STUCCO PANEL - - - - - - - - - - - - - - - - - - - - - - - - 2"X Im" ROS GEDAR WOOD FASCIA TYP. TEXTURED STUCCO � IP, \ ❑ C� FD 1:1 TU BABIED SMOOTH a FEII m 11:11 D - STUGCO BANDS TYP. ICI PRECAST OR FOAM SILL FE] F1 TYPICAL — — — — — — — — — — — — — — — — — — — — �E14 ELE%/,4TION SC ALE: 1/4 " = i' - co>" c�1 PLANNED UNIT DEVELOPMENT APPROVED DATE moo' ' / e ' ff" BOARD OF CN OOUNTY COMMISSION 7ekZ Chairman PRELIMINARY NOT FOR CONSTRUCTION -------------------------------------------- Final PUD Approval for Parcel #18 (Clubside) @ the Reserve (PUD II) Fi;z=,)C,)NT SCALE: LEFT SIF-:)E 'I�-4T 51EDEm- SCALE: M i LE IS] Ma 12 1 5.5 ELEv 20"i" ELEv 14'-1" — — ELEv 10'-I— — — ELEv � rtl FOAM COL 8 ARCH rJ------- -� ELEv©" I / 4 = 1' - 011 E L E %/,4 T I ON 1/4 " = P - CO)" ELE%/,4TI0N 1 /4 " = 1' - (0" MODEL 5240 BL FOR PERMIT FOR CONSTRUCTION ISSUE DATE: JULY 1, 1998 REVISIONS DATE: JOB NO: m 1 N z WZ O NOV W �W W V W � =J O N W W ]G .. V J m p r 0 0 v J ce 0-1 Z D I