Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS_2' LOad Short F6rm Job: Date: . Wrigkitso E'nfri hl®use- By: ; 1643 DONNA ROA ® ® - • • For: CENTEXHOMES,; MOORNINGSIDE ..- MODEL - 1577 SOUTH Wtg CIg Infiltration Outside db (OF) 42 Inside db (°F) 70 i -90 `75 Method Construction quality Simplified Average Design TD (°F) 28 + >15 Fireplaces 0 Daily range .7 L . Inside hi.imidity (%) 30 j50 " Moisture difference (gr/lb) 1 61 HEATING EQUIPMENT COOLING,EQUIPMENT Make Lennox, i' Make Lennox Trade 13HPD Series .: t A . Trade 13HPD Series Model 13H1'D-03' -236* i l Cond 13HPD-036-230* . Coil CB26UH-036* `Efficiency . -717 HSPF ' Efficiency 13 SEER , Heating input o Sensible cooling �B 24,640 tuh `Heating output 38600 ° B1hh @ 47 F . Latent cooling 10560 _I3tuh Temperature rise 26 °F' Total cooling 35200 Btuh Actual air flow 1178 cfm Actual air flow 1173 cfm. Air flow factor 0.047 cfro/Btuh Air, flow factor 0.046 cfm/Stuh Static pressure, 0.00 inv H2O Static pressure, 0.00. in H2O Space therm. ostat . Load sensible heat ratio 0.81 . ROOM NAME Area (ftz) Ntg load (Btuh) Clg load (Btuh) . Htg AVF . (cfm) 'CIO AVF FOYER . 147 4058 3735 ' 191. 173 .; POWDER : 50. 213 . 70 . 10 . 3 . . , GREAT ROOM 272;,:. 4424- 4006 . 208 18.6 DINING 144 j 3410 1908 '160 89 .' KITCHEN ". 224: i 3.083 2595, 145 120 . MASTER BEDROOM 186111 2487 : 31 11 117 144: WIC .. 50, C . 280 326 13 .' 15 LANDING 20 2539. 2561 119 119 BATH 2 451.4 1306 1164 61 .54 BEDROOM 2 192 1649 4457 77 207 Or' } 4c4o 4Qn4 71 R7 Entire House d 1577, 24962 25275 1173 ' 1173_. Other equip loads 1082 580 Equip.@ 0.95 RSM 24562 Latent cooling .6211 __-- • _ ���;11 1171 1173 +� wrightsofft Right-J Worksheet Entire House 1643 DONNA ROAD 1 Room name Entire House FOYER 2 Exposed wall 232,5 ft . 36.0 ft 3 Celling height 8.5 ft d 0.0 ft heat/cool 4 Room dimensions 7.0 ' ' x 21.0 ft 5 Room area 1577.0 ft? 147.0 ft' Ty Ty Construction number': LI-value ' °F) Or HTM' .. (BtulUfts) Area (W) or perimeter (ft) Load (Btuh) Area W) or perimeter (ft) Load (Bluh) Heat . Cool Gross : N/P/S. Heat Cool Gross : N/P/S Heat Cool .. 6 51A' 0.116 : n 3.25 ` 2 78 .252 165 536 459 0 0 0 0 1A-:0bmd 1.270 n 35.56 34.77 64 0 2276 2226 0 0 0 • . 0 1A-clom 1.270 n 35.56 c 34.77 23 0 818 800 0 0 0 0 yJ 12B-0bw 0.097 n 2.72 1.47 .224 185, 502 273 0 0 0 0 11 G 1A-clorn 17270 n' 35.56 34.77 '39 0 -' 1387 1356 0 0 0 0 .' W 51A' 0.116 a 3.25 2.78 . 252 252 818 • 702 0 0 0 ' . . , -0 ' W 1213-0bw 0.097 'e. 2.72 1.47 240 240 662 364 0 0 0 0 Val 51A . 0.116 s 3.25 . 2.78 63 43 ... 140 126 63 .. 43 146 120 Y--D •11PO : 0.290 s 8.12 8.41 20 ', 20 162 168 20 20 .162 '168 121370bw 0.097 s 2.72 1.47 192 154 418 227 ' ' : 0 0 0 0 G IA-c1om 1.270 s 35.66 . ';, 37.88 30 - 30 1067 1043 0 0. ' 0 0 1Ac1om 1.210 s 35.56 :37:88 8 8 284 278 0 0 0 0 51A 0.116 w 3.25 2.78 293 278 903 774 - 140 126 406 348 `1A-c1om 1:270 w 35,56 91.12 15 0 533 1367 15 0 533 1367 128=0bw 0.097 w 2,72 1:47 208 193 624 285 0 0 0 0 t---G 1A-clom 1.270 w 36.56 91.12 15 .1 533 1325 0 0 0 0 R 12B-0bm - 0.122 =: 3.42 - 256 .' 236 806 253 81 81 277 87 �--D Jim 0.290 n • 8.12 _1.07 8.41 `20 : 20 162 168 0 0 "_ 0 • 0 C 16A-19ad 0:049 - 1.37 ' 3.55 740 740 ..' 1016 2629 0 0 -.0 0 F_ .. 22A-tph 1.358 - 38.02 0.00 1305 92 3498 0 .. 147 36 1369 - .0 6 c) AED excursion` 434 Envelope loss/gain. 17037 14807 2887 2524 12 a) Infiltration 2622 739 309 r` ', 87 b) Room ventilation 0 ; 0 0 0 13 ' Intemalgains:`Occupants @ 230 4 920 0 O Appliances@ 1200 1 1200 0 .- `0 Subtotal (lines 6 to 13). .19659 .17666 3166 2611 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0- 0 0 0 14 Subtotal . _ i 19659 17666 3196 2611 15 Duct loads 27%43% 5303 7609 27% 43% 862 1125 Total room load ' ' 1 24962 2527b 4058 . 3735 Air required (cfm) 1173 1173 191 1 '3 Printout certified by ACCA to meet all requirements of Manual J 1 w° a"�utis®ez Right -Suite Residential 6 0 119'RSR43667 Ar-CK C.1Doc6ment9 and SettingsWngbept.PREFERREDAQW Documentslridht jlceentex moorningside 1577 SOUTH e +h1- wrightsoft- Righi�J Works,heet Er�tlre House 1643 DONNA ROAD POWDER GREAT ROOM 1 Room name 0.0 ft 33.0 ft 2 Exposed wail 9.0 ft heat/cool 9.0 ft heaticool 3 Ceilingheight 9 5:0 x 10.0 ft x 16.0 17.0 ft 9 'Room dimensions , 50.0 f1z 272.0 ft- 5 Room area Ty Construction 1-1-value Or HTM Area (ft') (ft) Load (.Btuh ) Area (ft') or perimeter (ft) Load (Btuh) number (Btuh/ft? °F) (Btuhlft') or perimeter Heat Cool Gross NIP/S Heat Cool Gross NIP/S . Heal Cool . 6 V1J. 51A2226 0.116 n 3.25 yr 2.78 ' 0 0 ' 0 0 0 144 64 80 0 260 223 F-GG 1A ciomd 1.270 n 35.56 t 34.77 0 0 0 0 0 0 0 I.227� . 1A-clom ' 1.270 n 35.56 ;34.77 0 0 '0 0 0 0 0 0 0 \tJL 12B-0bw' 0.097 n 2.72 1.47 0 0 0 0 0 0 0 0 11 1A-c1om 1.270 n 35.56 3.25 34.77 ".2.78 0 0 0 0 0 0 0 0 0 --h W W 51A 12B-0bw 0.116 0.097 a a 2.72 ? 1.47 0`. 0 0 0 0 0 0 0 0 0. 0 Val 51A 0.116 s 3.25 .- 2.78 0 0 0 0 0 0 0 0 0 0 0 L-D 11P0 0.290 s 8.12 8.41 . 0 0 0 0 0 0. 0 0 0 0 V�/i 12B-0bw 0.097 s 2.72 1.47 0 0 0 0 0 0 IA-ciom 1.270 s 3556 ,, 37.88 0 0 0- 0. 6 0 0 0 0 t IA-ciom 1.270 s 35 56 37.88 0 0 0 0 0 153 153 497 426 Val 51A 1A-clom 0.116 1.270 w w 3.25 35.50 2.78 91A2 0 0 0 0 0 0 0 - 0 _G V1J t-G 12B-0bw' 0.097 w 2.72 1.47 0 0 6 0 0 0 0 0 0 0 0 0 0 IA -clam , 1.270 0.122 w 3556 32 ,91.12 ' ; 1.07 0 49 0- 49 0 167 53 0 0 0 0 fl t-�fl 1213-0bm 11P0 0.290 - n 8,A2 ': 8.41 0 0 0 0 0 0 0 0 C - 16A-19ad 0.049 1.37 ;. ; 3.65 0 0 0 0 0 0 0 0 0 0 0 0 F 22A-tph 1.368 38.02 r 0.00 1 50 0 0 0 r, I r 6 c) AED excursion ( -4 202 Envelope losslga(n " 167 49 3033 2672 12 . a) Infiltration 0 0 452 127 b) Room ventilation I 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 .' 0 0 Appliances @ 1200' 0 0 0 0 Subtotal (lines 6 to 13)- 167 99 3484 2800 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution - 0 . 0 0 0 14 Subtotal 167 49 3484 2800 15 Duct loads 27% 43% 45 21 27% 43% -" 940 1,206 Total room load 213 70 4424 4006 Air required (cfm) - " 10 3 208 186 Printout certified by AOCA to meet all requirements of Manual J 8th Ed. _ Right -Suite Residential 6.0.i 19 RSR43667 2068-Apr-02 I3:36:24 P. C:\Documents and Settings\EngDept.PREFERREDAC\My Documents\right j\ceentex moorningslde 1577 SOUTH Page 2 -F - wlrightso t:" Right-J Worksheet Entire Douse' ; 1643 DONNA ROAD' ' ' DINING KITCHEN . 1 Room name 24.6 It .. 32.0 ft , 2 Exposed wall - 9.0 ft heat/cool 9.0 ft he ft cooi 3 Ceiling height . 12.0. x 12.0 ft 16.0 x 14: 4 Room dimensions 4 144.0 f►2 224.0 ft' 5 ' Room area ¢ " Ty Construction U value . Or Area ( (ftj Load (, fuh) Area ft' ( ) or perimeter (ft) Load (Btuh) number (Btuh/ft� °F) t (Btuti/ft2) et or .perimeter Heat ' Cool Gross N/P/S Heatg' Cool Gross WP/S Heat, Cool 6 51A 6A-clomd 0.116 n 3.25 12.78 108 :, 85 276 237 0 0 0 0 0 0 0 0 1.270 n 35.56 34.77 0` 23 0 0 "- -0 818 0 800 0 0 0 0 ' . G 1A-ciorn: 1.270 n 35.56 , 1 34.77 0 0 0 0 00 12B-0bvd 0.097 n 2.72 1.47 ,. A 0 .. 0 0 0 0 O 0` 11 t G ' 1A=ciom 1.270 0.116 n a 35.56 3.25 i 34.77 ` 2.78 108 108 : 351 301 144 144 468 401 W . 1N, 51A 128-0bw " O'.097 a 2:72 , ` 1.47 0 0 .. '0 - 0. 0 0 0 0 ' 0 0 - 0 0 0 0 V�I 51A 0.116 6 3.25 8.121 ' ,i 2.78 8.41 .: ` 0 '0 0 0 0 0 0 . 0 0 0 t D 11PO 128 Obw . 0.290 0.097 s s 2 72 1.47 - 0 0 0 .0 Q 0 0 0 0 0 0 0. 0` G iA-c1061 1.270 s 35.56 • j 37.88 0 0 0 0 0 0 0 0. 0 �-G IA-clom 1.270 s' 35.56 ' 37.88 ` 0 0 0 0 0 0: 0 0 0 VI!•' 511A .' 0,116 w 3.25 i. 2.78 0: 0 0 0 0 0 0 0 0 ' G VtJ 1A-clom 12B-0b,v 1.270 0.097 w w 35.56 2.72 91.12 1.47 0 .` 0 0 0-' 0 :. 0 0 0 t-G , 1Aciom 1.270 w 35.56' 97:12 ' 0- 0 0 0 0 0 0 0 126 0 106 - 0 362 .0 14 168 R t-- 120-0bm 0AU 0.290 3.42 t3.12 1.07 8.41 ; 0 0 0 0 0 20 ' 20 162 . 168 D C 1100 16A-19ad 0.049 1.358 n . -. - 1.37 38.02 3.65 0.00 . 0 144 0 - 0 913 0 0 0 224 -' 0 32 0 1217 0 ., 0 - F 22A-tph i.. .24 6 c) AED excursion : -96 131 Envelope loss/gain 2357 1241 2209 652 12 'a) Infiltration ... .. - 328 ., 93 219 62 b) ' Room ventilation 0 0 0 0 13 'Internal gains: Occupants @ 230; , 0 O 0 0 Appliances @ 1200' . 0 0 1 ...1200 Subtotal (lines 6 to 13) :. 281i6 1334 2428 1814 Less external load 0 0 0 .0 Less transfer 0 6 • 0 0 Redistribution 0 0 - 0 0 14 . Subtotal 2686 1334 2428 1614 15 .Duct loads 276/6 43% 724 574 27% 43% 665 781 Total room load 3410 .1908 3083 2595 Air required (cfm) 160 .. ' 89 - 145 120 Printout certified by ACC -4r Right -Suite Residential 6 0 1,10 C:1Documents and SeltingsT=ngDept.PREFERREDAC\My D,oci meet all requirements of Manual J 8th Ed.. 3667 s\dght llceentex moomingside 1577 SOUTH 1 Room name . MASTER 13ED.ROQM WIC 2 3 Exposed wall Ceiling height ` 27.0 ft 8.0 ft heat/cool 4.6. ft 8,0 4 heat/coal 4 5 Room dimensions Room area: 15.5. x . 12.0. ft 186.0 ft2 4.6 ' x 11.0 ft 49.5' ft' Ty. Consfruction . number U-value (BtutVft2-'F) Or - HTM (BtulVftl) . Area (ft2) or pedmeter,.(ft) Lead (13 h) Area (ft')' ." or perimeter (ft) Load (Btuh) •. Heat Cool Gross N/P/S Heat Cool Gross' N/P/S. Heat Cool - 6 11 51A- 1A-clomd IA-clom 12B-Obw 1A�c1om 61A 12B-Obw . 51A 0.116 1.270 1.270 0.097 1.270 6.116 0.097 0.116 n n n. n n a e s 3.25 35.66 35.56 2.72 35.56 3.25 . 2.72 3.25 2.78 34.77 34.77 .1.47 .34.77 2.78 -47 2.78 , 0- 0 0 120 24 0 96 0 '0 0 0 96 - 0 0 .. 96 0 0 0 0 261 853 0 261 '0 0 0 0 142 835 0 142 0 0 0 0 0 0 0 36 0 0 0 0 0 0 0 36 0 0 0 0 0 0 . 0 98 0 0 0 0 0 0 0 53 0 F--G rrr GGG Vf G _ W -- . W . .' V�1 l-D :11 po 12B-Obw. 1A-61om 1A c1om `" 61A 1A-c1om 12B.-0bw ; 1A-clom 0.290 0.697 1.270 1.270 0:116 1.270 0.097 1.270 s . i s' s w w w w 8.12 2 72 35.66 35.56 3.26 35 56 2.72 35:56 8.41 1.47 37:88 } 37.08 :, 2.78 .'. 91.12 , 1.47 t t91.12 0 ' .. 0 0 0 D' 0 0 0 0 '., 0 0 0 0 0 ': 0 0 0 0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 :" 0 0'• 0.' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -G r G V)l r G flfl r D 1213-0bm 0.122 - 3.42 1.07 0 0 0 0 0 0 0 0 11 P.0 -` 0.200 n 8.12 8.41 0 6 0 0 0 0 0 0 C 16A-19ad 0.040 - 1.37 3.55 -186 186 255 - 661 50 50 68 176 F 22A-tph 1.358 - 38.02 .' 0.00 , 1.66 0 0 0 50 0 0 0 f y , ' •, - - i .. 6 c) AEI excursion .. -167 -16 Envelope Ioss/gain 1630 "' ' 1622 166 213 12 - a) Infiltration b) Room ventilation 328 0 .. Q3 0 0 0 13 .. Internal gains. Occupants @ 230 Applianceg.@ 1200. . ; 2 0 % 460 0 0 ; : :'. 0 0 . 0 Subtotal (lines 6 to 13) i 1959 2174 220 228 14 15 Less external load Less transfer Redistribution f . Subtotal. Duct loads 27% 43%a 0 .0 0 1959 528 - 0 _0 0 2174 937 27% 43% ,,.0 0 0 220 59 0 0 0 228 98 Total. room load 2487 3111 280 326 Air required (cfm) 117 144 13 15 Printout certified by ACdA to meet all requirements of Man vac e�Eums® Rlght-Sulte Residential 6 0:11 iRSR436fi7 plCCia C \Documents and Settings\EngDept.PREFERREDAC\My l3 Uments\right I\ceentex moorningside 1577 SOUTH ,l Job: wrightsofi° Right-1 Worksheet Date: Entire House By: 1643 DONNA ROAD LANDING BATH 2 1 Room name 28.0 ft 14.0 ft 2 Ex osed wall P g•p ft heat/cool cool 8.0 heaUcool 3 Ceiling height 15.0 x 13.5 ft 5.0 x 9.0 ft 4 Room dimensions 5 Room area 202.5 ft? 45.0 ft2 U-value °F) Or HTM Area (ft') or (ft) Load (Btuh ) Area (ft') or perimeter (ft) Load (B.tuh) Ty Construction number (Btuh/ft2 (Btuhlft"') perimeter .. Heat Cool N/P/S Heat . Cool Gross NIP/S Heat Cool' . 0.116 n 3.25 ::: 2.78 rj 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 V�1 51A {-C IA-ciomd 1.270 n 35.56 34.77 0 0 0_ 0 0 0 0- L--G 1A Glom 1.270 n 35.56 34.77 0 0 0 0 0 0 0. U1J 12B-Obw 0.097 n 2.72 1.47 0 0 0 0 0 O 11 L--C 1A-ciom '. 1.270 n 35.56 3.25 34.77 2.18 0 0 0 0 0 0 0 W W 51A. 128-Obw 0:116 0.097 a a 2:72 i 1.47 108 108 .93 150 0 0 0 0 0 0 0 0 ._ 0 V�I 51A 0.116 s 3.25 2.78 0 0 0 0 0 0 0 0 0 0 0 L-D V�1 11130 . 12B-OUw 0.290 0.097 s .s 8.12 2.72 8.41 j 1.47 '37 .120 97 263 143 522 72 15 57 15 165 5 33 84 522 I-G 1A-ciom 1.270 s 35.56 i .88 15 8 ' 15 8 .533 278. 0 0 0 0 L-G IA-clom 1.270 0.116 s 35.56 3.25 : 37.88 2.78 0 0 .284 0 0 0 0. 0 0' t1G. 61A IA-clom 1.270 w w 35.56 ; 9.1.12 0 0 0 0 0 0 0 40 0 40 0 109 0 59 -VN 12B-Obvd 0.097 w 2.72 1.47 ' 0 0 0 0 0 0 6 0 0 0 1q ciom 1.270 w 35.56 01.12 0 0 0 0 0 0 0 --G R g D 128-0bm 0.122 0.290 n 3,42 8.12 :1.07 0 0 0 0 0 0 0 0 0 11P0 16A-19ad 0.049 . - 1.37 .8.41 ; . 8.55 203 203 278 719 45 45 .45 0 62 0 160 C _ F 22A-tph 1.358 38.02 0.06 203 0 0 0 .0 6 c) AED excursion _ -129 -59 'Envelope loss/gain 1652 1692 859 786 12 a) Infiltration ° 347 0 98 0 110 0 48 0 6) Room ventilation 13 . Internal gains: Occupants @ 230, i 0 0 0 0 0 0 O Appliances @ 1200� 0 .. Subtotal (lines 6 to 13) 1999 1790 1029 „ 814 Less externai load 0 0 •0 0 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 1999 - .1790 1029 814 15 Duct loads 27% 43% 639 771 27% 43% 278 -351 ITTotal room load 2539 2661 1306 1164 Air required (cfm) i 119 119 a 61 54 tiCGp.• C.\Documents and Settings\E rtified by ACCA to meet all regdrerhents of Mani Residential 6.0,119 RSR43667 ERREDAC\My bocuments\rightticeentex moomingside 1577 SOUTH 2008-Apr-0213:36:24 Page 5 wrightsoft" RightTJ Worksheet Entire House 1643 DONNA ROAD Job: Date: BY, 1 Room name. BEDROOM 2 16.6 ft MASTER BATH 18.0 ft 2 Ex wall 8.0 It heat/cool 8.0 ft hoat/cooll 3 ,ling height Ceiling , 16.0 x 12.0 ft 5.0 x 13.0 ft 4 Room dimensions 192.0 W , 65.0 ft• Room area -7- Ty Construction 0-value r Or H7kl Area (ft') Load (Btuh) Area or 'perimeter (ft) Load (Btuh) number (Btuh/W-?F) (Btuh",2) or perimeter Heat Cool Gross N/P/S Heat Cool Gross NIP/S, Heat Cool 6 VLI 51A 0.116 n 3 2 3.25 2.78 0 0 0 0 0 0 0 0 0 0 0 0 0 6 1A-clomd 1.270 n 35.56 5 5 34.77 0 0 0 0 0 0 0 IA-ciorn 1.270 0.097 n n 35.66 5 66 2.72 2 72 34.77 1.47 0 0 0 104 89 242 131 1 t-G 12B-Obvi - iA-ciorn 1.270 n 5 n356 35.56 i 34.77 0 0 .0 0 0 15 0 533 522 0 w 51A 0.116 e 3 - 25 3.25 -2.78 0 0 0 0 0 0 13 0 0 0 .0 0 0 W, 12B-Obw 61A 07097 0.116 e s 2 . 72 2.72 3.26 3 26 1.47.. 2.78 0 0 0 0 0 0 0 0 0 UPI IIPO 0.290 s . 8A2 8 . 1 2 8.41 0 0 0 0 0 0 0 0 0 0 12B-Obvv 0.097 s 2 . 72 232 1.47 0 0 0 0 0 0 0 0 iA-clom 1.270 s 35.56 37.88 0 0 a 0 0 0 0 0 0 0 IA-clorn 51A 1.270 0.116 S w 35.56 3.25, 37.88 2.78 0 0 0 0 0 0 0 0 Y-G IA-clom 1.270 0.097 w 35.56 2.72 91,12 1.47 a 128 0 113 0 307 0 167 0 40 0 40 0 109 0 59 VI! E . 12B70bvv 1A-clom 1.270 w w 35.56 91.12 15 1 633 1325 0 0 0 0.0 _G t-E�D i2-Obrn 0.122 - 3.42 1.01 0 0 0 0 0 0 0 0 .0 0 0 IIPO 16A-1 9ad 0.290 0.049 n - 8.12. 1.371 8.41 3.55 0 192 0 192 0 263 682 65 65 89 231 C F 22A-tph 1.358 - 38.02 0.00 192 0 0 0 65 0 0 0 6 c) AED excursion' 426 -68 Envelope loss/gain 1104 2600 973 875 12 a) Infiltration 195 65 219 62 b) Room ventilation 0 0 0 0 13, n�n .l internal gains: Occupants230 @ 2 460 0 0 200! Appliances01 0 0 0 Subtotal (lines 6 to,13) 1298. 3115 1192 937 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1298 3115 1192 931 16 Duct loads 27% .43% 350 1342 27% 43% 322 404 Total mom load 1649 4457 1513 1 1 341 Air required (qfm) 77 2071 .1 711 62 Printout certified by AGGA to meet. all requirements of Manual J 8th Ed. A- Right -Suite Residential 6.0. il 9 RSR43667 20 08-Apr-02 1 3:36:24 C:%Documents and SettingskEngDept.PREFERREDACkMy DocumenWright jkceentex moomlngside 1577 SOUTH Page 6 DATE 10/12/07 PAGE 1 ® Universal Forest Products RE: X07-471 CENTEX HOMES MORNINGSIDE MASTERS PHASE Site Information: Project Customer: CENTEX HOMES Project Name:MORNINGSIDE MASTERS PHASE II Lot/Block: Model:1577 B Address: Subdivision: MORNINGSIDE City: FORT PIERCE State: FL General Truss Engineering'Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions Design Code: FBC2004lTP12002 Design Program: MiTek 20/20 6.3 Wind Speed: 130 mph Roof Load: 20.0,15.0,0.0,10.0 Floor Load: 40.0,10.0,0.0,5.0 No. Job # Truss ID. Date No. I Job # Truss ID. Date 1 X07-471 Al 10/12/07 26 X07-471 C4 10/12/07 2 X07-471 A10 10/12/07 27 X07-471 C5A 10/12/07 3 X07-471 All 10/12/07 28 X07-471 C51JI 10/12/07 4 X07-471 A3 10/12/07 29 X07-471 CA 10/12/07 5 X07-471 A4 10/12/07 30 X07-471 D1 1 on 2107 6 X07-471 A5 10/12/07 31 X07-471 D2 10/12/07 7 X07-471 A6 10/12/07 32 X07-471 E5 10/12/07 8 X07-471 A7 10/12/07 33 X07-471 E5A 10/12/07 9 X07-471 A8 10/12/07 34 X07-471 E5B 10/12/07 10 X07-471 , A9 10/12/07 35 X07-471 E5U 10/12/07 11 X07-471 B1 10/12/07 36 X07-471 E7 10/12/07 12 X07-471 B2 10/12/07 37 X07-471 E71J 10/12/07 13 X07-471 B3 10/12/07 38 X07-471 K01 10/12/07 14 X07-471 B4 10/12/07 39 X07-471 K02 10/12/07 15 X07-471 B5 10/12/07 40 X07-471 K4U 10/1 2/07 16 X07-471 B6 10112/07 l 41 X07-471 K6U 10/12/07 17 X07-471 B7 10/12/07 42 X07-471 K7U 10/12/07 18 X07-471 B8 10/12/07 43 X07-471 K8 10/12/07 19 X07-471 B9 10/12/07 44 X07-471 K9U 10/12/07 20 X07-471 C 1 A 10/12/07 45 X07-471 V4 10/12/07 21 X07-471 C1U 10/12/07 46 X07-471 V8 10/12/07 22 X07-471 C2 10/12/07 47 X07-471 F01 10/12/07 23 X07-471 C2A 10/12/07 48 X07-471 F02 10/12/07 24 X07-471 C3A 10/12/07 49 X07-471 F03 ,ll"11 i 10/12/07 25 X07-471 C3U 10/12/07 50 X07-471 F04 ,�`� — �ii]o112/07 The truss rirnwinnk) refren(-Pri ahnve have been nrenared by MiTek ,��G ,...... •, .� Industries. Inc. �� r V •' .� % R 9•n. _ ••_ Jn►._- under my direct supervision based on the parameters provided by UFP-Ft.Pierce, FL. ,At Truss Design Engineer's Name: Tan, Seng-Chaff �,y, �• Fi7 5 Ny license renewal date for the state of Florida is February 28,2009. NOTE: The seal on these drawings indicate acceptance of S7E A ',�N'%,. P professional engineering responsibility solely for the truss , seng•Chai Tan, FL Lic #46765 �,��t� •• i-.,.:� components shown. The suitability and use of this component for any particular / ,` WAlhambra '�i;S,0111A L West Palm Beach, Wes, FL 33405 r1rNir building is the responsibility of the building designer, per MiTek Industries, Inc. ��i��ttN`�� FL Cert.#6634 OCT 1 ANSI/TPI-1 Chapter 2 6 2007 This package includes ��� individual, dated truss design drawings and 0 Additional drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31. 3, section 5 of Florida Board of Professional Engineers Rules. I I DATE 10/12/07 PAGE 2 MIts Universal Forest Produc 'RE: X07-471 CENTEX HOMES MORNINGSIDE MASTERS PHASE Site Information: Project Customer: CENTEX HOMES Lot/Block: Address: City: FORT PIERCE Project Name:MORNINGSIDE MASTERS PHASE II Model: 1577 B Subdivision: MORN INGSIDE State: FL No Job # Truss ID. Date .1 1 X07-471 F05 10/12/07 52 X07-471 F06 10/12/07 53 X07-471 F07 10/121Q7 54 X07-471 FG1 10/12/07 55 X07-471 FG2 10/12/07 56 X07-471 FG3 10/12/07 57 X07-471 FG4 10/12/07 8en9-Chas Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 V�C'E�s•• h�.o. '�7 5 OCT 1 6.2007 Job Truss Truss Type pty Ply Centex Homes, Model 1577 A X07-471 Al HIP UniversallFEqeProduct, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5-2007 MiTek Industries, Inc. Fri Oct 12 08:13jb5�Y7 Page 1 9-2-11 14-3-10 19-4-9 24-7-4 28-6-8 1-0-0 4-0-0 5-2-11 5-0-15 5-0-15 5-2-11 3-11A Scale = 1:50. 5.00[12 5x8 =_ 4x6 = T it 5x8 4x6 = 15 14 13 12 11 10 5x7 II 18-8-0 5x8 = 4x6 = 18-8-0 4_0_0 9-2-11 14-3-10 19-4-9 24-7-4 27-7-4 $8-6-$ 4-0-0 5-2-11 5-0-15 5-0-15 5-2-11 3-0-0 0-11-4 LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 10.0 Rep Stress Incr NO BCDL 10.0 Code FBC2004ITP12002 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.2 WEDGE Right: 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1901/0-3-8, 9=1814/0-3-8 Max Horz 2=46(LC 3) Max Uplift2=-1000(LC 3), 9=-869(LC 3) CSI DEFL in (loc) I/defl L/d PLATES GRIP TC 0.88 Vert(LL) 0.41 13 >829 360 MT20 2441190 BC 0.87 Vert(TL) -0.80 13 >423 180 WB 0.29 Horz(TL) 0.12 9 n/a n/a (Matrix) Weight: 258 lb BRACING TOP CHORD Structural wood sheathing directly applied or 4-7-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-7-5 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-4142/1997, 3-4=-6729/3344, 4-5=-7671/3806, 5-6=-7671/3806, 6-7=-7671/3806, 7-8=-6713/3346, 8-9=-4112/2019 BOT CHORD 2-15=-1781/3750, 14-15=-1777/3762, 13-14=-3257/6729, 12-13=-3260/6713, 11-12=-3260/6713, 10-11 =-1 799/3738, 9-1 0=-1 802/3726 WEBS 3-15=0/236, 3-14=-1557/3171, 4-14=-846/531, 4-13=-488/1019, 6-13=-496/354, 7-13=-485/1037, 7-11=-851/527, 8-11=-1537/3185, 8-10=0/239 NOTES 1) 2-ply truss to be connected together with 1 Od (0.131 "xY) nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 5) Provide adequate drainage to prevent water ponding. 6) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All plates are 4x4 MT20 unless otherwise indicated. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1000 lb uplift at joint 2 and 869 lb uplift at joint 9. 9) Girder carries hip end with 3-11-4 right side setback, 4-0-0 left side setback, and 4-0-0 end setback. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 115 ib down and 93 lb up at 24-7-4, and 117 lb down and 95 lb up at 4-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Job Truss Truss Type Qry Ply Centex Homes, Model 1577 A X07A71 Al HIP 1 _ 2 Job Reference Coptional) -._ Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:15 2007 Page 2 LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-8=-100(F=-30), 8-9=-70, 2-9=-29(F=-9) Concentrated Loads (Ib) Vert: 3=-117(F) 8=-115(F) 1 Job Truss Truss Type - pry " Ply Centex Homes, Model 1577 A - -- X07-471 A10 SPECIAL 1 1 Job_Reference (optional). UniversalApip5t Product, Inc. E359, Vero Beach, FI. 32967 ' 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:194VC07 Page 1 I 4.3-I _0'0 {_122_14 -- i---.1_.. i q {...-- 23 -3-6 - - { 1-0-0 4-3-14 3-8-2 4-2-14 4-2-14 3-1-8 3-8-2 4-3-14 1-0-0 Scale = 1:51.2 5.00 j i z 18-8-0 5x7 = 5x8 = 4x4 II 3 4 5 6 6x8 - 17 16 15 14 11 4x4 = 44 II 4x4 li 4x4 W 7 W�� 8 0 L= 10 0 18-8-0 8-0-0 12-2-14 16-5-12 19-10-8 27-7-4 8-0-0 4-2-14 4-2-14 34-12 7-8-12 Plat_e Offsets (X,YL Z..-1_10,0-0-�j,_j6:0_3-0�0_1_lA,LO_0_2-8,0-2-0 , 12:0-6-0,0-4 0 13:0-3-4 0_3=01 1A.Edge,0-3-81_(16:0-2-12 0-2- LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ltd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.63 Vert(LL) 0.25 12-13 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.56 12-13 >580 180 BCLL 10.0 Rep Stress Incr YES WB 0.46 Horz(TL) 0.22 8 n/a n/a BCDL •10.0 Code FBC2004/TPI2002 (Matrix) Weight: 143 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-5 oc purlins. BOT CHORD'2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-6-9 oc bracing. Except: WEBS 2 X 4 SYP No.2 6-0-0 oc bracing: 5-13 REACTIONS (lb/size) 2=131310-3-8, 8=1313/0-3-8 Max Uplift2=-649(LC 3), 8=-649(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2449/1021, 3-4=-2176/1015, 4-5=-3863/1679, 5-6=-3926/1691, 6-7=-3873/1591, 7-8=-2657/1086, 8-9=0/27 BOT CHORD 2-17=-795/2158, 16-17=-923/2443, 15-16=-75/215, 14-15=-75/215, 13-14=0/107, 5-13=-266/174, 12-13=-1283/3514, 10-11=-32/83, 8-10=-893/2380 WEBS 3-17=-87/491, 4-17=-510/161, 4-16=-713/315, 13-16=-892/2343, 4-13=-602/1587, 6-13=-226/615, 7-10=-847/385, 11-12=0160, 6-12=-336/978, 10-12=-928/2476, 7-12=-393/1152 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 649 lb uplift at joint 2 and 649 lb uplift at joint B. LOAD CASE(S) Standard Job Truss Truss Type pty Ply. Centex Homes, Model 1577 A X07-471 All I HIP 1 2 Job Reference optional).- _ UniversallF��bl Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 20l)7 Milek Industries, Inc. Fri Oct 12 08:13:18-iqP Page 1 1 1-1-3-0--------1-----_16-4-4 1-0-0 6-0-0 5-3-0 5-1-4 5-3-0 6-0-0 1-0-0 Scale = 1:50.3 `I 0 5.00 r12 5x7 :-- 3 4 5x7 = 6 4x6 = 13 12 11 10 9 4x6 17 5x8 = 4x6 = 18-8-0 F_ 6-0-0 T_ 11-3-0 16-44 21-74 27-74 6-0-0 5-3-0 5-14 5-3-0 6-0-0 LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 10.0 Rep Stress Incr NO BCDL 10.0 Code FBC2004/TP12002 LUMBER TOP CHORD -2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=2388/0-3-8, 7=238810-3-8 Max Uplift2=-1251(LC 3), 7=-1251(LC 3) . 18-8-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TC 0.37 Vert(LL) 0.2610-12 >999 360 MT20 244/190 BC 0.67 Vert(TL)-0.5110-12 >644 180 WB 0.20 Horz(TL) 0.13 7 n/a n/a (Matrix) Weight: 249 lb BRACING TOP CHORD Structural wood sheathing directly applied or 5-0-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-7-11 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-5176/2627, 3-4=-6513/3419, 4-5=-6513/3419, 5-6=-6515/3421, 6-7=-5175/2626, 7-8=0/27 BOT CHORD 2-13=-2294/4686, 12-13=-2290/4700, 11-12=-3246/6514, 10-11=-3246/6514, 9-10=-2289/4700, 7-9=-2293/4686 WEBS 3-13=0/353, 3-12=-1060/2117, 4-12=-713/519, 5-12=-43/40, 5-10=-732/520, 6-10=-1063/2119, 6-9=0/353 NOTES 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. - Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; C-C Intedor(1); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 5) Provide adequate drainage to prevent water ponding. 6) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All plates are 4x4 MT20 unless otherwise indicated. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1251 lb uplift at joint 2 and 1251 lb uplift at joint 7. 9) Girder carries hip end with 6-0-0 end setback. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 315 lb down and 256 lb up at 21-7-4, and 315 lb down and 256 lb up at 6-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-6=-135(F=-65), 6-8=-70, 2-7=-39(F=-19) Concentrated Loads (lb) Vert: 3=-315(F) 6=-315(F) Job Truss Truss Type X07471 A3 SPECIAL Universal Fo{%s�Paoduct, Inc. E359, Vero Beach, FI. 32967 11-0- 6-0-0 13.9.10 1-0-0 6-0-0 7-9-10 Oty Ply Centex Flomes,-Model 1577 A 1 1 Job Reference joptionaD.._ _ 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 Oqd _�-& 2007 Page 1 21-7-4 25-2-12 -2-1 28-6-B 7-9-10 3-7-8 1-0-0 2-3-12 Scale = 1:52. 5x10 = 5.00 12 5x10 3 4 5 • --- -- - — - T2 —^--— 4x6 = 1 W2 W2 I 6 7 CN 2 8 i 4x6 13 12 11 10 9 5x8 11 5x8 = 46 18-8-0 18A %-8 6-0-0 13-9-10 21-7-4 26-2-12 27�— 7�� 6-0-0 7-9-10 7-9-10 4-7-8 1-4-80-11-4 ria�o viiscw L^� r/.:. _lt_V;�-o,u-u-Lf, LJ:V-4_o,V-L_4J, 1tl_U_Z_1ZL=U�_Ltf_U-U-/,1-1-6lltl:U-U-t3 ttl9t1,. IU:U-1-1 Z,0-2-U ..-'— LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.82 Vert(LL) 0.29 12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 Be 0.81 Vert(TL) -0.64 10-12 >528 180 BCLL 10.0 Rep Stress Incr NO WB 0.60 Horz(TL) 0.14 8 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight 132 lb rl_UMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-6-4 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly -applied or 5-1-6 oc bracing. WEBS 2 X 4 SYP No.2 WEDGE Right: 2 X 6 SYP SS REACTIONS (lb/size) 2=1360/0-3-8, 8=1303/0-3-8 Max Horz 2=46(LC 3) Max Uplift2=-685(LC 3), 8=-601(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2747/1181, 3-4=-3689/1722, 4-5=-3689/1722, 5-6=-2960/1346, 6-7=-2583/1223, 7-8=-2742/1269 BOT CHORD 2-13=-1016/2459, 12-13=-101412468, 11-12=-117512751, 10-11=-117512751, 9-10=-151513350, 8-9=-1117/2452 WEBS 3-13=0/295, 3-12=-610/1397, 4-12=-568/379, 5-12=-441/1092, 5-10=-68/418, 6-10=-640t356, 6-9=-11991538, 7-9=-386/936 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 685 lb uplift at joint 2 and 601 lb uplift at joint 8. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 71 lb down and 42 lb up at 26-2-12 on top chord, and 9 lb down and 13 lb up at 26-2-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-5=-70, 5-6=-70, 6-7=-70, 7-8=-70, 2-8=-20 Concentrated Loads (lb) Vert: 7=-31(B) 9=-5(B) Iq 0 Job 1 Truss Truss Type Qiy - Ply Centex Homes, Model t577 A X07-4 71 i A4 HIP 1 1 i Job Reference (optional) _ . - ... _ _ . . UniversallF��� Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:1�2a0a Page 1 F1-0--9 .. --- — B 0 13-9-10 19-7-4 -----._...--- �- - — ---i - 27-7-4 - -- 1-0-0 8-0.0 5-9-10 5-9-10 8-0-0 Scale = 1:50.0 5x10 MT181-1= 5x10 MT1811= 4x6 == 10 9 8 7 4x6 = 5x8 = 4x6 = 18-8-0 8-0-0 13-9-10 19-7-4 27-7-4 8-0-0 5-9-10 5-9-10 8-0-0 18-8-0 LOADING 20.0 SPACING 2-0-0 CSI DEFL in (loc) I/deft Ltd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.70 Vert(LL) 0.17 6-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.43 6-7 >770 180 MT18H 244/190 BCLL ' 10.0 Rep Stress Jncr YES WB 0.11 Horz(TL) 0.11 6 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 118 lb LUMBER ---—_-------�- --- BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-14 oc purlins. BOT CHORD.2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-4-5 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (Ib/size) 6=1227/0-3-8, 2=1315/0-3-8 Max Horz 2=46(LC 3) Max Uplift6=-520(LC 3), 2=-652(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2461/1032, 3-4=-2502/1175, 4-5=-2502/1175, 5-6=-2470/1049 BOT CHORD 2-10=-853/2170, 9-10=-852/2178, 8-9=-870/2189, 7-8=-870/2189, 6-7= 870/2180 WEBS 3-10=01327, 3-9=-177/540, 4-9=-354/214, 5-9=-156/533, 5-7=0/330 NOTES 15 Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 44 MT20 unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 520 lb uplift at joint 6 and 652 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Truss Type qty Ply Centex Mo del odel 1577 A X07-471 A5 HIP 1 1 _ - 1400R!�ferrce (opfionai) .... .. ....... . Universall%)[pe Product, Inc. E359, Vero Beach, FI. 32967 6,500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:4g_JC187 Page 1 1_0 5-7-2 10-0-0- 1-0-0 5-7-2 4-4-14 5x7 4 17-7 4 _ 22-0-2 27-7-4 8-7- 7-7-4 4-4-14 5-7-2 1-0-0 Scale = 1:50., 6x8 = 5 5x5 11 10 9 5x5 -= 5x8 = 46 = 18-8-0 18-8-0 10-0-0 i 17-7-4 27-7-4 10-0-0 7-7-4 10-0-0 Plate Offsets &' j2:0-3_2;0-0-2L14:0-4-0,0-2=4] 0-3-4,0-2-8],[7:0-3-2,0-0-21 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.52 Vert(LL) -0.23 7-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.77 Vert(TL) -0.68 7-9 >484 180 BCLL 10.0 Rep Stress Incr YES WB 0.15 Horz(TL) 0.11 7 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 127 lb LUMBER TOP CHORD 2 X 4 SYP N0.2 BOT CHORD 2 X•4 SYP N0.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=131310-3-8, 7=1313/0-3-8 Max Uplift2=-639(LC 3), 7=-639(LC 3) BRACING TOP CHORD Structural wood sheathing directly applied or 3-4-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-9-14 oc bracing. WEBS 1 Row at midpt 5-11 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2501/1063, 3-4=-2126/922, 4-5=-19281904, 5-6=-2126/922, 6-7=-2501/1063, 7-8=0/27 BOT CHORD 2-11=-857/2249, 10-11=-646/1927, 9-10=-646/1927, 7-9=-857/2249 WEBS 3-11=-372/237, 4-11=-53/444, 5-11=-152/153, 5-9=-53/444, 6-9=-372/236 NOTES t) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 44 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 639 lb uplift at joint 2 and 639 lb uplift at joint 7. LOAD CASE(S) Standard r - __ _.-. 'Job Truss �HIP Truss Typ__..._e ptyX07.471 IA6 1 1 Universal F Product, Inc. E359, Vero Beach, FI. 32967 Job Reference 1�� 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:la087 Page 1 1. 9 6-3-14 12-0-0 15.7-4 21-3-6 27-7-4 8-7- 1-0-0 6-3-14 5-8-2 3-7-4 5-8-2 6-3-14 1-0-0 Scale = 1:50.: 06 = 4x6 = 4 5 06 -- 12 11 10 9 06 = 18-8-0 6-10-2 6-10-2 _Plate Offsets_(X�Y)__j41-12],.[5_0_3-0_0_1 _1_, LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 10.0 Rep Stress Incr YES BCDL 10.0 Code FBC20041TPI2002 LUMBER TOP CHORD 2,X 4 SYP N0.2 BOT CHORD 2 X 4 SYP N0.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1313/0-3-8, 7=1313/0-3-8 Max Uplift2=-628(LC 3), 7=-628(LC 3) 4x6 = 18-8-0 13=9-10 20-9-2 27-7-4 6-11-8 6-11-8 6-10-2 CSI DEFL in (loc) I/deft L/d PLATES GRIP TC 0.40 Vert(LL) 0.12 11 >999 360 MT20 2441190 BC 0.61 Vert(TL) -0.3111-12 >999 180 WB 0.32 Horz(TL) 0.10 7 n/a n/a (Matrix) Weight: 132 lb BRACING TOP CHORD Structural wood sheathing directly applied or 3-6-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-0-1 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3 2543/999, 3-4=-2527/1136, 4-5=-1669/797, 5-6=-2527/1136, 6-7=-2543/999, 7-8=0/27 BOT CHORD 2-12=-790/2257, 11-12=-504/1644, 10-11=-504/1644, 9-10=-504/1644, 7-9=-790/2257 WEBS 4-12=-395/849, 4-11=-49/201, 5-11=-49/201, 5-9=-395/849, 3-12=-4231307, 6-9=-423/307 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 44 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 628 lb uplift at joint 2 and 628 lb uplift at joint 7. LOAD CASE(S) Standard - Job Truss Truss Type . - qry - �Piy-'," Centex Homes,Model 1577AX07-471 A7 COMMON 1 1 - JobReference (optional) Universal eTProduct, Inc. E359, Vero Beach, FI. 32967 6.500 Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:17 a0g-(Fage 1 I 1-0-0 7-2:11 13-9-10 20 4 9 27.7 :4_ _ ..-- 8 7- i 1-0-0 7-2-11 6-6-15 6-6-15 7-2-11 1-0-0 Scale = 1:49.3 5.00 12 18-8-0 9-5-5 5 12 11 10 4x4 = 4x4 = 8-1-15 �— - - - 27-7-4 -- 8-8-9 9-5-5 1 8-8-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0,48 Vert(LL) -0.17 2-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.68 Vert(TL) -0.55 2-12 >599 180 BCLL 10.0 Rep Stress Incr YES WB 0.21 Horz(TL) 0.10 8 nla n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 121 lb LUMBER BRACING TOP CHORD .2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-13 oc purlins. BOT CHORD . 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-0-12 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1313/0-3-8, 8=1313/0-3-8 Max Uplift2=-619(LC 3), 8=-619(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 273=-2473/980, 3-4=-2161/899, 4-5=-2067/919, 5-6=-2067/919, 6-7=-2161/899, 7-8=-2473/980, 8-9=0127 BOT CHORD 2-12=-769/2195, 11-12=-410/1477, 10-11=-41011477, 8-10=-769/2195 WEBS 3-12=-491/328, 5-12=-264/739, 5-10=-264/739, 7-10=-491/328 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x6 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 619 lb uplift at joint 2 and 619 lb uplift at joint 8. LOAD CASE(S) Standard Job Truss Truss Type Qry Ply Centex Homes, Model 1577 A i X07-471 A8 HIP 1 1 I Job Reference (optional) UniversaliF��bt Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:131y_V87 Page 1 1-1 -Q 1 _6-3-14 -9 -15 7 4._...._.a -- - . _21-3-6— 27-7-4T8-7 f 1-0-0 6-3-14 5-8-2 3-7-4 5-8-2 6-3-14 1-0-0 Scale = 1 4x6 4x6 = 4 5 i'T 0 4x6 = 12 11 10 9 4x6 -- 4x6 = 18-8-0 18-8-0 I_ 6_10-2 13-9-10 20-9-2 27-7-4 6-10-2 6-11-8 6-11-8 6-10-2 Plate Offsets -{X`Y)__j4:0-3-0,0-1-121 [5:0-3-0_0-1._ 2] — — LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.40 Vert(LL) 0.12 11 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.61 Vert(TL) -0.31 9-11 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.32 Horz(TL) 0.10 7 n/a n/a BCDL 10.0 Code,FBC2004/TPI2002 (Matrix) Weight: 132lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-6-1 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-0-1 oc bracing, WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1313/0-3-8, 7=1313/0-3-8 Max Uplift2=-628(LC 3), 7=-628(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-2544/999, 3-4=-2528/1137, 4-5=-1670/797, 5-6=-2528/1137, 6-7=-2544/999, 7-8=0/27 BOT CHORD 2-12=-791/2259, 11-12=-504/1645, 10-11=-504/1645, 9-10=-504/1645, 7-9=-791/2259 \ WEBS 4-12=-396/850, 4-11=-49/201, 5-11=-49/201, 5-9=-396/850, 3-12=-424/307, 6-9=-424/307 NOTES 1,) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 628 lb uplift at joint 2 and 628 lb uplift at joint 7. LOAD CASE(S) Standard Job i Truss ; Truss Type X07-471 i A9 SPECIAL Universalilimbt Product, Inc. E359, Vero Beach, FI. 32967 Oty Ply Centex Homes, Model 1577 A 1 1 Job.Reference (optional) .. 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:157_IV007 Page 1 1 0 5-7-2 10-0-0 16-5-12 17-7- 19-10-8 27-7-4 1-0-0 5-7-2 4-4-14 6-5-12 1-1-8 2-3-4 7-8-12 5x8 = 4 46 = 5 6 I 8-7 1-0-0 Scale = 1:51.3 5x5 = 17 16 15 12 11 4x6 = 5x8 = 4x6 = 4x6 = 18-8-0 10-0-0 16-5-12 17-7-4 19-10-8 10-0-0 6-5-12 1-1-8 2-3-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Lid TCLL 20.0 Plates Increase 1.25 TC 0.44 Vert(LL) -0.23 2-17 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 0.69 Vert(TL) -0.69 2-17 >478 180 BCLL 10.0 Rep Stress Incr YES WB 0.45 Horz(TL) 0.19 9 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) 18-8-0 27-7-4 7-8-12 PLATES GRIP MT20 244/190 Weight: 150 lb LUMBER" BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 3-1-2 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-7-13 oc bracing. Except: WEBS 2 X 4 SYP No.2 6-0-0 oc bracing: 5-14, 7-13 'REACTIONS (lb/size) 2=131310-3-8.9=1313/0-3-8 Max Up1ift2=-639(LC 3), 9=-639(LC 3) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=•2511/1067, 3-4=-2116/913, 4-5=-2830/1243, 5-6=-2836/1231, 6-7=-3809/1584, 7-8=-3789/1518, 8-9=-2632/1054, 9-10=0127 BOT CHORD 2-17=-862/2259, 16-17=-32/109, 15-16=-32/109, 14-15=0/86, 5-14=-344/221, 13-14=-898/2670, 12-13=-11167, 7-13=-140/110, 11-12=-68/166, 9-11=-859/2354 WEBS 3-17=-405/258,4-17=-80/162,14-17=-610/1831,4-14=-392/1062,8-11=-973/415,11-13=-872/2415,8-13=-364/1121,6-14=-186/503,6-13=-514/1290 .NOTES 1) Unbalanced rooflive loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B;renclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. c 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 639 lb uplift at joint 2 and 639 lb uplift at joint 9. LOAD CASE(S) Standard Job Truss Truss Type X07-471 I81 HIP i Universal Fps6Product, Inc. E359, Vero Beach, FI. 32967 1-0-0 1-0-0 6-0-0 3.00 12 5x7 = Qty.- Ply . Centex Homes, Model 1577 A 1— 2Job Reference_(optional) 6mo s Feb 52007 MiTek Industries, Inc. Fri Oct 12 08:13g18_? .nP07 Page -- 10-8-8 10-8-8 15-5-0 4-8-8 4-8-8 5x7 = 6-0-0 1-0-0 Scale = 1:39 4xb '= 11 10 9 8 4x6 = 9-0-0 5x8 = 4x6 = 6-0-0 10-8-8 15-5-0 21-5-0 6-0-0 4-8-8 4-8-8 6-0-0 LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 10.0 Rep Stress Incr NO BCDL 10.0 Code FBC2004/TP12002 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD .2 X 4 SYP N0.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) `2=1798/0-7-8, 6=1798/0-7-8 Max Uplift2=-918(LC 3), 6=-918(LC 3) 9-0-0 CSI DEFL in (loc) I/deft Ltd PLATES GRIP TC 0.31 Vert(LL) 0.25 10 >990 360 MT20 244/190 BC 0.64 Vert(TL) -0.50 10 >495 180 WB 0.13 Horz(TL) 0.10 6 n/a n/a (Matrix) Weight: 173 Ib BRACING TOP CHORD Structural wood sheathing directly applied or 5-1-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 8-9-2 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-5515/2617, 3-4=-6460/3170, 4-5=-6460/3170, 5-6=-5516/2617, 6-7=0/16 BOT CHORD 2-11=-2455/5282, 10-11=-2448/5301, 9-10=-2448/5301, 8-9=-2448/5301, 6-8=-2455/5282 WEBS 3-11=01322, 3-10=-649/1374, 4-10=-629/441, 5-10=-649/1374, 5-8=0/322 NOTES 1), 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Intedor(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 5) Provide adequate drainage to prevent water ponding. - 6) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) All plates are 4x4 MT20 unless otherwise indicated. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 918 Ib uplift at joint 2 and 918 Ib uplift at joint 6. 9) Girder carries hip end with 6-0-0 end setback. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 315 Ib down and 228 Ib up at 15-5-0, and 315 Ib down and 228 Ib up at 6-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. - LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-5=-129(F=-59), 5-7=-70, 2-6=-37(F=-17) -- Concentrated Loads (lb) Vert: 3=-315(F) 5=-315(F) Job Truss Truss Type Qty Ply Centex Homes, Model 1577 A X07-471 I B2 HIP 1 1 L. _. ... ... _ _........_..... -- ...._ ._... _... _.... -- __ _ _ Jo_b Reference (o tionaL Uni 1 Forest Product, Inc. E359, Vero Beach, FI. 32967 P - - I �a 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:11� a007 Page 1 8"0_0 1 13 5 0 ._ .... ......I - - - ..._ 21-5_0- 122-5-01 8-0-0 5-5-0 8-0-0 1-0-0 Scale = 1:37.9I 3.00 12 5x10 -- 5x6 = 2 3 T2 -- IV 2 LLL 0 8 7 6 4x4 11 4x4 = 9-0-0 —__�-- 8-0-0 i 13-5-0 — 21-5-( r- 8-0-0 5-5-0 8-0-0 Plate Offsets (X,Y):_ LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d TCLL 20.0 Plates Increase 1.25 TC 0.62 Vert(LL) 0.18 1-8 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 0.78 Vert(TL) -0.49 1-8 >508 180 BCLL 10.0 Rep Stress Incr YES WB 0.12 Horz(TL) 0.09 4 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) LUMBER BRACING 9-0-0 PLATES GRIP MT20 2441190 Weight: 79 lb TOP' CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 3-0-8 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid beiling directly applied or 6-2-4 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=933/0-7-8, 4=1033/0-7-8 Max Horz 1=-26(LC 3) Max Upliftl=-384(LC 3), 4=-535(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-2549/1060, 2-3=-2396/1038, 3-4=-2531/1031, 4-5=0/16 BOT CHORD 1-8=-940/2403, 7-8=-939/2414, 6-7=-939/2414, 4-6=-911/2384 WEBS 2-8=0/277, 2-6=-273/244, 3-6=01276 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 384 lb uplift at joint 1 and 535 lb uplift at joint 4. LOAD CASE(S) Standard V to 'Job Truss Truss Type , X07-471 B3 HIP Uni§e&al Forest Product, Inc. E359, Vero Beach, FI. 3 I967 I 5-4-14 5-4-14 3.00 f 12 9-0-0 �ty Ply Centex Homes, Model 1577 A 1 1 I Jo_b Reference (optional)__. 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:1:b18 3007 Pagel 10-0-0 11-5-0 16-0-2 21-5-0 22-5-0 -- — - - ---- F--- -t - -- - -- -- - i -- --- - - - - - -I ..... _.� 4-7-2 1-5-0 4-7-2 5-4-14 1-0-0 Scale = 1:37.9 5x7 _ 3 4 9 8 5xB = 5xl0 = 9-0-0 10-0-0 11-5-0 , 21-5-0 10-0-0 1-5-0 10-0-0 i._Plate Offsets L: 0-2-12_8:0-5-0,01-3-0__-_ LOADING (psf) SPACING _ 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.40 Vert(LL) -0.21 6-8 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.86 Vert(TL) -0.63 6-8 >393 180 BCLL 10.0 Rep Stress Incr YES WB 0.26 Horz(TL) 0.10 6 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 91 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-6 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-10 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (Iblsize) 1=933/0-7-8, 6=1033/0-7-8 Max Horz 1=-26(LC 3) Max Upliftl=-374(LC 3), 6=-525(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-2741/1166, 2-3=-2094/833, 3-4=-2006/838, 4-5=-2080/824, 5-6=-2713/1124, 6-7=0/16 BOT CHORD 1-9=-1061/2620, 8-9=-675/2000, 6-8=-1016/2590 WEBS 2-9=-669/393, 3-9=-68/324, 4-9=-152/170, 4-8=-36/313, 5-8=-652/355 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4j "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 06 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 374 lb uplift at joint 1 and 525 lb uplift at joint 6. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply Centex Homes, Model 1577 A j i X07-471 B4 SPECIAL 1 1 ..._ Job Reference Universal Fob BroducL Inc. E359, Vero Beach, FI93a_W7 - --- - - 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:19.307 - 1 4-0-0..... 1 _.. §-10.12 _.. F - -- 10-7-0---f— pPage 1-0-0 4-0-0 2-10-12 3-8-4 2-9-15 3-10-9 5-1-14 5-6-10 1-0-0 Scale = 1:51.8 3.00 I 12 9-0-0 16 18 15 14 13 12 11 4x6 '— 5x8 = 9-0-0 4x6 = 5x8 = 9-0-0 4-0-0 6-10-12 10-7-0 17-3-8 22-5-6 28-0-0 4-0-0 2-10-12 3-8-4 6-8-8 5-1-14 5-6-10 Plate Offsets �,Y�_LO_3 4,0-0-2], [3:0-5-4,0-2-8 , 5:0-5-8,0-2-81, [7:0-2-0,0-2-81 _ LOADING (psi) SPACING 2-0-0 CSI DEFL in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.72 Vert(LL) 0.12 11-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.64 Vert(TL) -0.32 12-14 >779 180 BCLL 10.0 Rep Stress Incr NO WB 0.61 Horz(TL) 0.06 9 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 123 lb LUMBER TOP CHORD 2 X 4 SYP N0.2 BOT CHORD 2 X 4 SYP N0.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=159/0-3-8, 15=1812/0-7-8, 9=930/0-7-8 Max Uplift2=-169(LC 3), 15=-744(LC 3), 9=-482(LC 3) Max Grav2=208(LC 4), 15=1812(LC 1), 9=930(LC 1) BRACING TOP CHORD Structural wood sheathing directly applied or 3-10-4 oc pudins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-155/407, 3-17=-660/1782, 4-17=-660/1782, 4-5=-660/1782, 5-6=-1004/451, 6-7=-1546/645, 7-8=-1562/642, 8-9=-2386/914, 9-10=0/16 BOT CHORD 2-16=-360/200, 16-18=-346/207, 15-18=-346/207, 14-15=-351/1015, 13-14=-578/1531, 12-13=-578/1531, 11-12=-814/2259, 9-11=-814/2259 WEBS 3-16=0/245, 3-15=-1523/563, 4-15=-369/221, 5-15=-2904/1130, 5-14=-77/405, 6-14=-661/275, 6-12=-1871131. 7-12=-1031429, 8-12=-852/338, 8-11=0/190 NOTES -1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 44 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 169 lb uplift at joint 2, 744 lb uplift at joint 15 and 482 lb uplift at joint 9. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 198 lb down and 72 lb up at 4-0-0, and 88 lb down and 30 lb up at 6-0-12 on top chord, and 120 lb down at 4-0-0, and 36 lb down at 6-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-5=-70, 5-7=-70, 7-10=-70, 2-9=-20 Concentrated Loads (lb) Vert: 3=-118(F) 16=-60(F) 17=-48(F) 18=-18(F) i. Job Truss -- Trusa Type - • - - - pty- � ply Centex Homes, Model 1577 A I X07-471 B5 SPECIAL 1 1 -- - Universal Fog$_6roduct, Inc. E359, Vero Beach, Fj. 32967 6.50-0 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13: 16_3CL 97 Pagel 1 0 6-0-0 12-7.0 17-3-8 22-1.4 28-0-0 1-0-0 6-0-0 6-7-0 4-8-8 4-9-12 5-10-12 I 3.00 12 5x10 = dvR — 4x6 ::- 5 _ 90 1-0-0 Scale = 1:51.8j I i 10 5x7 - 13 12 11 10 9 5x6 5xl0 MT18H WB= 5x8 = 9-0-0 9-0-0 12-7-0 17-3-8 22-1-4 28-0-0 , 6-0-0 6-7-0 4-8-8 4-9-12 5-10-12 Edge]13:0_6-0,0-2-81, [4 0-3-4,0-2-41, [7:0-4-9,EdgeL [12:0-1-12,0-1-121 — — --^ ^-- --- LOADING (psf) I SPACING 2-0-0 CSI TCLL 20.0 Plates Increase L25 TC 0.88 CLLTCDL 15.0 Lumber Increase 1.25 BC 0.83 BCLL 10.0 Rep Stress Incr YES WB 0.99 BCDL 10.0 Code FBC2004ITP12002 (Matrix) LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.1 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1326/0-7-8, 7=1326/0-7-8 Max Uplift2=-658(LC 3), 7=-647(LC 3) DEFL in (loc) I/deft L/d PLATES GRIP Vert(LL) 0.50 12 >652 360 MT20 244/190 Vert(TL) -1.1312-13 >290 180 MT18H 244/190 Horz(TL) 0.19 7 n/a n/a Weight: 120 lb BRACING TOP CHORD Structural wood sheathing directly applied or 2=0-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-4-8 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-3942/1612, 3-4=-5414/2279, 4-5=-3121/1300, 5-6=-3123/1299, 6-7=-3837/1515, 7-8=0/16 BOT CHORD 2-13=-1488/3763, 12-13=-1484/3778, 11-12=-2196/5444, 10-1 l=-2196/5444, 9-10=-1391/3657, 7-9=-1391/3657 WEBS 3-13=0/274, 3-12=-710/1682, 4-12=-319/216, 4-10=-2578/1128, 5-10=-428/1143, 6-10=-772/281, 6-9=0/200 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4-) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 4x4 MT20 unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 658 lb uplift at joint 2 and 647 lb uplift at joint 7. LOAD CASE(S) Standard Job Truss Truss Type Qry Oiy I Centex Homes, Model 1577 A i X07471 I B6 SPECIAL 1 1 Reference (optional)_ - Universal Fobeg-groduct, Inc. E359, Vero Beach, FI. 32967 —6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:2�_aT7 Page 1 1-0 8-0-0 14-7-0 17-3-8 21-11-1 _28-0-0 49-0- 1-0-0 8-0-0 6-7-0 2-8-8 4-7-9 6-0-15 1-0-0 Scale = 1:51.8 5x10 = 4x6 = 4x6 - 5 5x6 = 12 11 10 9 5x6 = 5x8 == 4x6 = 9-0-0 9-0-0 8-0-0 14-7-0 20-5-14 28-0-0 8-0-0 6-7-0 5-10-14 7-6-2 Plate Offsets�X Y�_ [2:0-4-9,Edgel,[3:0-4-12,0-2-81,.[4:0-2-8,0-2-41, [5:0-2-8,0-2-01, [7:0-4-9,Edgel LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.74 Vert(LL) 0.38 11 >859 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.91 Vert(TL) -0.86 11 >383 180 BCLL 10.0 Rep Stress Incr YES WB 0.34 Horz(TL) 0.17 7 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 116 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-4-4 oc pur[ins. BOT CHORD 2 X 4 SYP No.2 - BOT CHORD Rigid ceiling directly applied or 5-3-3 cc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1326/0-7-8, 7=1326/0-7-8 Max Uplift2=-656(LC 3), 7=-649(LC 3) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-3719/1523, 3-4=-4154/1772, 4-5=-4403/1897, 5-6=-3542/1440, 6-7=-3828/1551, 7-8=0/16 BOT CHORD 2-12=-1388/3536, 11-12=-1386/3549, 10-11=-1118/2928, 9-10=-1118/2928, 7-9=-1425/3649 WEBS 3-12=0/319, 3-11=-270/635, 4-11=-1345/660, 5-11=-788/1822, 5-9=-184/641, 6-9=-378/232 NOTES I-) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1) cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 44 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 656 lb uplift at joint 2 and 649 lb uplift at joint 7. LOAD CASE(S) Standard Job (Truss -Truss Type X07-471 87 SPECIAL Universal FoTV-groduct, Inc. E359,Vero Beach, FI. 32967 Oty Ply Centex Homes, Model 1577 A 1 1 i o�tiona�.---..---:----•----....------- --- - 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:4-3tp Page 1 i 20-83--F — 28-0-0 _— 9-0-t 1-0-0 5-4-14 4-7-2 6-7-0 0-8-8 3-4-11 7-3-13 1-0-0 Scale = 1:51. 3.00 r-1 2 5x6 5x6 5x8 = v IM 6 5x6 = 13 12 11 10 5x6 = 5x8 4x6 9-0-0 10-0-0 16-7-0 21-8-1 28-0-0 10-0-0 6-7-0 5-1-1 6-3-15 ,Ed2eL [4:0-3-0,0-2-121, [5:0-5-4,0-3-41, [8:0-4-9,Edgel LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 10.0 Rep Stress Incr YES BCDL 10.0 Code FBC2004/TP12002 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1326/0-7-8, 8=1326/0-7-8 Max Uplift2=-653(LC 3), 8=-652(LC 3) 9-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TC 0.54 Vert(LL) 0.3111-13 >999 360 MT20 244/190 BC 0.93 Vert(TL) -0.83 2-13 >396 180 WB 0.23 Horz(TL) 0.17 8 n/a n/a (Matrix) Weight: 125 lb BRACING TOP CHORD Structural wood sheathing directly applied or 2-9-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0116, 2-3=-3778/1588, 3-4=-3278/1361, 4-5=-3167/1355, 5-6=-3403/1498, 6-7=-3617/1458, 7-8=-3922/1604, 8-9=0/16 BOT CHORD 2-13=-1461/3614, 12-13=-1279/3274, 11-12=-1279/3274, 10-1 1=-1 167/3005, 8-10=-1485/3746 WEBS 3-13=-503/271, 4-13=-41/436, 5-13=-252/93, 5-11=-1067/455, 6-11=-458/1226, 6-10=-142/588, 7-10=-375/234 NOTES 1-) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 653 lb uplift at joint 2 and 652 lb uplift at joint 8. LOAD CASE(S) Standard - — _.—._.__.. --- ------..._.__---------- I Job � Truss j Truss Type Qty Ply Centex Homes, Model 1577 A X07-471 68 I HIP 1 1 I _ Job Reference joptional)-. Universal -twt Product, Inc. E359, Vero Beach, FI. 32667 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:2_ 3_T7 Page 1 i 11-0-9 _.6 5-6 1.. ...._.._._12_Q-O.._ 1-0-0 6-5-6 5-6-10 4-0-0 5-6-10 6-5-6 1-0-0 Scale = 1:50.8 3.00 12 V1 2 5x6 _- 4x6 - 4x6 = 4 5 11 10 9 Sx6 -- 5x5 = 9-0-0 9-0-0 14-0-0 20-2-5 28-0-0 7-9-11 6-2-5 6-2-5 7-9-11 _ LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.45 Vert(LL) 0.29 10 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.85 Vert(TL) -0.67 10-11 >488 180 BCLL 10.0 '10.0 Rep Stress Incr YES WB 0.14 Horz(TL) 0.16 7 n/a n/a BCDL Code FBC2004/TP12002 (Matrix) Weight: 119 lb LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 2-10-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-3-12 oc bracing. WEBS 2 X 4 SYP N0.2 REACTIONS (lb/size) 2=1326/0-7-8, 7=1326/0-7-8 Max Uplift2=-646(LC 3), 7=-646(LC 3) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16. 2-3=-3811/1535, 3-4=-3510/1422, 4-5=-2778/1198, 5-6=-3510/1422, 6-7=-3811/1535, 7-8=0/16 BOT CHORD 2-11=-1409/3633, 10-11=-1027/2737, 9-10=-1027/2737, 7-9=-1409/3633 WEBS 3-11=-415/264, 4-11=-250/774, 4-10=-67/213, 5-10=-67/213, 5-9=-250/774, 6-9=-415/264 NOTES 1.) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. �) All plates are 44 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 646 lb uplift at joint 2 and 646 lb uplift at joint 7. LOAD CASE(S) Standard Job Truss j Truss Type qty ply Centex Homes, Model 1577 A I • X07-471 B9 COMMON 1 1 _. .... _ . _.. _ . _ Job Reference (optional)_- j UniversalB-Vvt Product, Inc. E359, Vero Beach, FI. 32967 - - - - - 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08�13:21 ?� age 1 4-0-020-5 8 28 0-0 g-0- 1-0-0 7-6-8 6-5-8 6-5-8 7-6-8 1-0-0 Scale = 1:� 5x5 = 3.00 r2 4 5x6 '== 10 9 8 5x6 = 4x6 = 9-0-0 9-0-0 I--- -------- 9-8-5--- --- �— - 18-3-11 28-0-0 i 9-8-5 8-7-5 9-8-5 Plate_Offsets_(_X,Y)_(2:0-4-9,Edge]_ 4:0-2-8,0-2-121, [6:0-4-9,Edgel -- LLOADING (psf) SPACING 2-0-0 CSI DEFL in floc) I/deft L/d PLATES GRIP CLL 20.0 Plates Increase 1.25 TC 0.64 Vert(LL) 0.29 8-10 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.92 Vert(TL) -0.76 2=10 >433 180 BCLL 10.0 Rep Stress Incr YES WB 0.17 Horz(TL) 0.16 6 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 112 lb LUMBER BRACING TOP CHORD 2'X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-6-10 oc purlins. BOT CHORD 2.X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1326/0-7-8, 6=132610-7-8 Max Uplift2=-636(LC 3), 6=-636(LC 3) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-3704/1471, 3-4=-3247/1278, 4-5=-3247/1278, 5-6=-3704/1471, 6-7=0/16 BOT CHORD 2-10=-1340/3525, 9-10=-864/2425, 8-9=-864/2425, 6-8=-1340/3525 WEBS 3-10=-587/348, 4-10=-266/898, 4-8=-266/898, 5-8=-587/348 NOTES 1}Unbalanced roof live loads have been considered forthis design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 636 lb uplift at joint 2 and 636 lb uplift at joint 6. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply Cen►ex Homes, Model 1577 A X07.471 C 1 A JACK 6 1 - - - -. ...._ ._ Job Reference..(qgioq�1)- ----: -- Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 9 6.560 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08: F----- --- ---- -- 1-0 - ----------- 1-6-6-0 1-0-0 1-6-0 3.00 f12 2 1 T1 CA B1 4x4 = 1-6-0 4 9-4-6 i 70 Page 1 ; le 1; J I 9-4-6 9-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) -0.00 2 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) -0.00 2 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 6 lb LUMBER ------�----- --- -- -- BRACING ---- -- — TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-6-0 oc purlins. BOT CHORD 2.X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=167/0-3-8, 4=15/Mechanical, 3=24/Mechanical _ Max Horz 2=49(LC 3) Max Uplift2=-182(LC 3) Max Grav2=167(LC 1), 4=29(LC 2), 3=24(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-21/4 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. A) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 182 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Truss Type - -- - -- --- - pty-- Ply- Centex Homes, Model 1577 A - -- - --- X07-471 C1U MONO TRUSS 7 1 -- - ...._ _ .. - - -- -- - - - - .. Job Reference op Uonal — Universal Forest Product, Inc. E359, Vero each, FI. 32967 16 8 0 6.500 s Feb 5 2007 MiTek Industrieg, Inc. Pt12 06:13:21 2007 Page 1 l� 1-0-0 4x4 = 1 O 0 I LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d i TCLL 20.0 Plates Increase 1.25 TC 0.17 Vert(LL) -0.00 2 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 0.00 Vert(TL) -0.00 2 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 Scale = 1:4.f PLATES GRIP MT20 244/190 Weight: 5 lb BRACING TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=230/1-0-0, 4=711-0-0, 3=-80/Mechanical, 3=-80/Mechanical Max Horz2=71(LC 3) Max Uplift2=-320(LC 3), 3=-80(LC 1), 3=-80(LC 1) Max Grav2=230(LC 1), 4=13(LC 2), 3=145(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-71/81 BOT CHORD '2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 320 lb uplift at joint 2 and 80 lb uplift at joint 3. LOAD CASE(S) Standard Job Truss I Truss Type X07471 C2 i JACK Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 it Qty Ply 1 Snbex Homes. Model 1577 A 2 1 Job Reference (optional) 6.5200 s Fgg_8-a007 MiTek Industries, Inc. Fri Oct 12 08:13:21 2007 Page 1 4x4 -- 3 19-0-10 18.8-0 0-11-4 0-11-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) -0.00 1 n/r 180 TCDL 15.0 Lumber Increase 1.25 BC 0.03 Vert(TL) -0.00 1 n/r 90 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) LUMBER BRACING r IMPSON MTS 16 PLATES GRIP MT20 2441190 Weight: 3 lb Scale = 1:4. TOP CHORD 2 X 4 SYP N0:2 TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc purlins. BOT CHORD 2 X 4 SYP No:2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 3=9/Mechanical, 2=74/Mechanical Max Horz 3=136(LC 3), 2=-112(LC 3) Max Uplift3=-38(LC 3), 2=-81(LC 3) Max Grav3=19(LC 2), 2=74(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-139/107 BOT CHORD 1-3=-87/136 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 38 lb uplift at joint 3 and 81 lb uplift at joint 2. 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard ffl Job Truss I Truss Type X07-471 I C2A JACK Universal Forest Product, Inc. E359, Vero Beach, FI. 3296V 0-0 1�1 Qty Ply Centex Homes, Model 1577 A 4 1 10-2-10 _ —..- _ Job Reference (op!ona)..-- 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 04 R 2007 Page 1 1-0-0I a_n-n le: 1.5"= 1 LOADING (psf) TCLL 20.0 TCDL 15.0 BCLL 10.0 BCDL 10.0 SPACING 2-0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr YES Code FBC2004/TPI2002 CSI TC 0.12 BC 0.08 WB 0.00 (Matrix) DEFL in Vert(LL) -0.00 Vert(TL) -0.01 Horz(TL) -0.00 (loc) I/deft L/d 2-4 >999 360 2-4 >999 180 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 11 lb LUMBER BRACING TOP CHORD ' 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=81/Mechanical, 2=22710-3-0, 4=28/Mechanical Max Horz 2=116(LC 3) Max Uplift3=-53(LC 3), 2=-196(LC 3) Max Grav3=81(LC 1), 2=227(LC 1), 4=56(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-47/25 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category Il; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2)-"This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 53 lb uplift at joint 3 and 196 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Truss Type Qty T�,­,Ten6x HomeX07-471 CM JACK 6 . ._..Reference ....._ . Universal Forest Product, Inc. E359, Vero Beach, 51.03a967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:22 i - 9-0-0 f— Plate Offsets_(X,Y);__L2.0.3-4,0-0-21 LOADING__:__:._._T_==—_--_---•------ (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 rB CDL 15.0 Lumber Increase 1.25 CLL 10.0 Rep Stress Incr YES CDL 10.0 Code FBC2004/TP12002 LUMBER . TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 3-0-0 3-0-0 3-0-0 3-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TC 0.11 Vert(LL) -0.00 2-4 >999 360 MT20 244/190 BC 0.07 Vert(TL) -0.01 2-4 >999 180 WB 0.00 Horz(TL) -0.00 3 n/a n/a (Matrix) Weight: 11 lb BRACING TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=80/Mechanical, 2=226/0-3-8, 4=28/Mechanical Max Horz 2=69(LC 3) Max Uplift3=-44(LC 3), 2=-203(LC 3) Max Grav3=80(LC 1), 2=226(LC 1), 4=56(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-30/16 BOT CHORD 2-4=0/0 NOTES 1-) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Intedor(1); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 44 lb uplift at joint 3 and 203 lb uplift at joint 2. LOAD CASE(S) Standard 9-0-0 Job Truss Truss Type X07-471 I C3U i MONO TRUSS Universal Forest Product, Inc. E359, Vero Beach, Fl. 329%-8-0 Qty - 101y. Fly Centex Homes, Model 1577 A 7 I 1 19-10-10 Job Reference (optional) 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08jV�2007 Pagel -1-0-0 ;_n_n : 1.5"=1 1-----4x4=- ---- -- — ---- ------ — ---1 3-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP _ TCLL 20.0 Plates Increase 1.25 TC 0.12 Vert(ILL) -0.00 2-4 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) -0.01 2-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL, 10.0 . Code FBC2004/TPI2002 (Matrix) Weight: 11 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=80/Mechanical, 2=228/0-3-8, 4=28/Mechanical Max Horz 2=116(LC 3) Max Uplift3=-51(LC 3). 2=-199(LC 3) Max Grav3=80(LC 1), 2=228(LC 1), 4=56(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-48/25 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 51 lb uplift at joint 3 and 199 lb uplift at joint 2. LOAD CASE(S) Standard ,r ----- - --- -- - - - 'Job Truss Truss Type l]ty Ply- Centex Homes, Model 1577 A X07-471 C4 MONO TRUSS 1 1 198te-00 _____ _ ____ _ _ Job Reference (optional-_-_.-..___._,_.____ _ Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967 18_8 - 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:22 2007 Page 1 Scale: 1.5"=1 4x4 3 198te-00 18 - 0-11-4 2-11-4 0-11-4 2-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.12 Vert(LL) -0.00 1-3 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) -0.01 1-3 >999 180 BCLL 1.0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a' BCOL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 10 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc purlins. BOT CHORD .2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 2=96/Mechanical, 3=27/Mechanical, 1=123/0-3-8 Max Horz 1=70(LC 3) Max Uplift2=-81(LC 3), 1=-40(LC 3) Max Grav2=96(LC 1), 3=55(LC 2), 1=123(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-42/32 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)'Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 Ib uplift at joint 2 and 40 lb uplift at joint 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply Centex Homes, Model 1577 A j X07-471 C5A JACK 4 1 10 -2-1 .. _ ..... Universal Forest Product, Inc. 05Q_- _�o Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:22 2007 Ply -ea I -1-0-0 1-0-0 5-0-0 Scala = 1: V0.1 2 4x4 = 9-0-0 3.00 12 T1 B1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ltd TCLL 20.0 Plates Increase 1.25 TC 0.28 Vert(LL) -0.02 24 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 0.20 Vert(TL) -0.06 2-4 >924 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) PLATES GRIP MT20 244/190 Weight: 17 Ito 4 10-2-1 9-0-0 LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2 X 4 SYP No,2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=148/Mechanical, 2=316/0-7-8, 4=46/Mechanical Max Horz 2=97(LC 3) 'Max Uplift3=-98(LC 3), 2=-249(LC 3) Max Grav3=148(LC 1), 2=316(LC 1), 4=93(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-46/30 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 98 lb uplift at joint 3 and 249 lb uplift at joint 2. LOAD CASE(S) Standard `Job Truss !truss Type iX07-471 C5U MONO TRUSS Universal Forest Product, Inc. E359, Vero Befgtg Fd. 32667 I Oty Ply Centex Homes, Model 1577 A 4 1 . Job Reference (optional)..- ..--_ .._ ._20-8-10 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 z007 Page 1 i I Scale = 1:12., -- - . 18-8-0 4x4 18-8-0 5-0-0 LOADING (psf) TCLL 20.0 TCDL 15.0 BCLL 10.0 BCDL 10.0 SPACING 2=0-0 Plates Increase 1.25 Lumber Increase 1.25 Rep Stress Incr YES Code FBC2004/TP12002 CSI TC 0.32 BC 0.22 WB- 0.00 (Matrix) DEFL in Vert(LL) -0.03 Vert(TL) -0.07 Horz(TL) -0.00 (loc) I/deft L/d 2-4 >999 360 2-4 >831 180 3 n/a nla PLATES GRIP MT20 244/190 Weight: 17 lb LUMBER BRACING TOP CHORD '2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied of 5-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=157/Mechanical, 2=31010-3-8, 4=481Mechanical Max Horz2=162(LC 3) Max Uplift3=-121(LC 3), 2=-217(LC 3) Max Grav3=157(LC 1), 2=310(LC 1), 4=96(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-71/49 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3,Opsf; Category II; Exp B; enclosed; C-C Intedor(1) cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 27 *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 121 lb uplift at joint 3 and 217 lb uplift at joint 2. LOAD CASE(S) Standard -- ...-.- ...... Job Truss - Truss Type. I X07-371 CA JACK Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 Qty Ply - Centex Homes, 9-4-10 4 1 - -- - - - - . - --- - -- - Job Referer q2Jo;Lbonal)- -- - - -- - -- -- ---- 9-0-0 6.500 s Feb 5 2007 MiTek Industries, 3Inc. Fdp6td2 08:13:22 2007 Page 1 1-0-0 _- 1-0-0 LOADING (psf) SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 10.0 Rep Stress Incr YES BCDL 10.0 Code FBC2004ITP12002 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD :2 )(4 SYP No.2 Scale = 1:4.f CSI DEFL in (loc) I/deft Ltd PLATES GRIP TC 0.10 Vert(l. Q -0.00 2 >999 360 MT20 2441190 BC 0.01 Vert(TL) -0.00 2 >999 180 WB 0.00 Horz(TL) -0,00 3 n/a n/a (Matrix) Weight: 5 lb BRACING --- - '- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (Ib/size) 2=161/0-3-0, 4=10/Mechanical, 3=-9/Mechanical Max Horz 2=71(LC 3) Max Uplift2=-201(LC 3), 3=-9(LC 1) Max Grav2=161(LC 1), 4=19(LC 2), 3=45(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-32/19 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2r*This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 201 lb uplift at joint 2 and 9 lb uplift at joint 3. LOAD CASE(S) Standard Job Truss Truss -Type -- Qty- Ply - - Centex Homes, Model 1577 A -- -- X07-471 D1 HIP 1 1 Job Reference_Cop ional...... - - _ --- --- ---•- - ._. _...--. I Universal Forest grec ct, Inc. E359, Vero Beach, FL 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 _0:23 2007 Page 1 {....-0-0 _. ... _._ 1-0-0 4-0-0 4-0-0 4-0-0 1-0-0 Scale: 1/2"=1 5x7 = 5.00 12 3 4 8 .7 9-0-0 9-0-0 4"0 0 8-0-0 12-0-0 { 4-0-0 4-0-0 4-0-0 _Plate Offset�X,Y); 3:0-5-4,0-2 a ,14:0_2-0,0-2-4]— LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.19 Vert(LL) 0.04 7-8 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.31 Vert(TL) -0.08 7-8 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.04 Horz(TL) 0.03 5 n/a n/a BCDL — 10.0 Code FBC2004/TP12002 (Matrix) Weight: 50 lb LUMBER BRACING 6 Io TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-1-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 8-4-9 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 2=841/0-3-0, 5=841/0-3-0 Max Uplift2=-490(LC 3), 5=-490(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-1498/729, 3-4=-1337/701, 4-5=-1498/728, 5-6=0/27 BOT CHORD 2-8=-571/1327, 7-8=-567/1337, 5-7=-569/1327 WEBS 3-8=0/195, 3-7=-78/79, 4-7=0/195 NOTES 1). Unbalanced roof live loads have been considered for this design, 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x4 MT20 unless otherwise indicated. 6) Provide mechanical'connection (by others) of truss to bearing plate capable of withstanding 490 lb uplift at joint 2 and 490 lb uplift at joint 5. 7) Girder carries hip end with 4-0-0 end setback. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 117 lb down and 98 lb up at 8-0-0, and 117 lb down and 98 lb up at 4-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 3-4=-101(F=-31), 4-6=-70, 2-5=-29(F=-9) Concentrated Loads (lb) Vert: 3=-117(F) 4=-117(F) JobTruss iTruss Type C1ty Ply Centex Homes, Model 1577 A X07-471 D2 I COMMON 1 1 II Job Reference I Universal Forest ?r6dWct, Inc. E359, Vero Beach, Fl. 32967 - 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 N.:b2i 2007 Page 1 0- -1-0-0 1-0-0 9-0-0 6-0-0 4x6 =- 3 12.0-0 6-0-0 1-0-0 Scale = 1 9-0-0 12-0-0 6-0-0 6-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.32 Vert(LL) -0.03 4-6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.31 Vert(TL) -0.09 4-6 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.05 Horz(TL) 0.02 4 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 44 lb LUMBER TOP CHORD .2 X 4 SYP N0.2 BOT CHORD •2 X 4 SYP N0.2 WEBS 2 X 4 SYP No.2 REACTIONS .(Ib/size) 2=611/0-3-0, 4=61110-3-0 Max Uplift2=-346(LC 3), 4=-346(LC 3) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-864/319, 3-4=-864/319, 4-5=0/27 BOT CHORD 2-6=-174/727, 4-6=-174/727 WEBS 3-6=0/278 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Intedor(1); .cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 04 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 346 lb uplift at joint 2 and 346 lb uplift at joint 4. LOAD CASE(S) Standard Fd l Job Truss Truss Type X07-471 E5 JACK Universal Forest Product, Inc. E359, VerVEW, FI. 32967 2 9-0-0 �ty Ply Centex Homes. Model 1577 A 1 1 9-11- _.___ Job Referen92 __ptional _. 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:23 2007 Rana 4-0-0 4-0-0 Sole = 11 3.00 12 kE T— , 61 4x4 4-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFT in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.19 Vert(LL) -0.01 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.14 Vert(TL) -0.03 2-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 14 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2 X 4 SYP No:2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=120/Mechanical, 2=266/0-3-8, 4=38/Mechanical 'Max Horz2=83(LC 3) Max Uplift3=-77(LC 3), 2=-215(LC 3) Max Grav3=120(LC 1), 2=266(LC 1), 4=76(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-37/24 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 1) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 3 and 215 lb uplift at joint 2. _OAD CASE(S) Standard Job Truss (Truss Type X07471 E5A I JACK Universal Forest Product, Inc. E359, Vero Beac"_02967 Qty Ply Centex Homes, Model 1577 A 3 1 j ... _ Jo Reference (optional)_ _ .-1 0 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13�.bTd07 Page 1 ; n_n_n ---- — -- ---------- 4-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.19 Vert(LL) -0.01 2-4 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.14 Vert(TL) -0.03 2-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 14 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD .2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=121/Mechanical, 2=267/0-3-0, 4=38/Mechanical Max Horz2=139(LC 3) Max Uplift3=-89(LC 3), 2=-204(LC 3) Max Grav3=121(LC 1), 2=267(LC 1), 4=76(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-59/38 SOT CHORD 2-4=0/0 VOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2?'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. i) Refer to girder(s) for truss to truss connections. t) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 89 lb uplift at joint 3 and 204 lb uplift at joint 2. _OAD CASE(S) Standard Job Truss j Truss Type y Centex Homes, Model 1577 A � X07.471 E513 (JACK 1 1 9-11-141 Job. Refe_renteA2p nal)_.,__......_.__.._—. _ Universal Forest Product. Inc. E359, Vpr�lpach, FI. 32967 - 6.500 s Feb 5 2007 MiTJ Industries, Inc. Fri Oct 12 08:13:23 2007 P��pa 0-11-0 4-0-0 Sc'3ale = 11 3.00 12 T1 2 ' 1 _� B, 4x4 = ' 4 9-0-0 4-0-0 LOADING (psf) ' SPACING 2-0-0 CSI DEFL in (loc) I/deft Ltd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.19 Vert(LL) -0.01 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.14 Vert(TL) -0.03 2-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a nla BCDL 10.0 Code FBC20041TP12002 (Matrix) Weight: 14 lb LUMBER BRACING 9-11-1 9-0-0 TOP CHORD 2.X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2"X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=122/Mechanical, 2=259/0-3-8, 4=38/Mechanical Max Horz 2=80(LC 3) Max Uplift3==-80(1-C 3), 2=-203(LC 3) Max Grav3=122(LC 1), 2=259(LC 1), 4=76(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/15, 2-3=-37/24 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) `This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3 and 203 lb uplift • at joint 2. LOAD CASE(S) Standard i Job Truss Truss Type Qty Ply Centex Homes, Model 1577 A I X07.471 E5LI MONO TRUSS 12 1. 20-3- 0 Universal Forest Product. Inc. E359, Vero Beac46Fh 3u2967 JobReferenceoptionalZ____.___..__ - - 6.500 s Feb 6 2007 MiTek Industries, Inc. Fri Oct 1-2 08:13jJ482807 Page 1 1-0-0 a-n-n = 1:9.1 4-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP LOADING (psf) I SPACING 2-0-0 TCLL 20.0 Plates Increase 1.25 TC 0.18 Vert(LL) -0.01 2-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.14 Vert(TL) -0.03 2-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL- 10.0 Code FBC2004/TP12002 (Matrix) Weight: 14 lb LUMBER, BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=119/Mechanical, 2=268/0-3-8, 4=38/Mechanical Max Horz2=139(LC 3) Max Uplift3=-88(LC 3), 2=-206(LC 3) `Max Grav3=119(LC 1), 2=268(LC 1), 4=76(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-59/37 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 21 *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 88 lb uplift at joint 3 and 206 lb uplift at joint 2. LOAD CASE(S) Standard Job Truss Truss Type X07-471 iE7 JACK Universal Forest Product, Inc.Vero Beach, FI. 32967 4x4 Qty Ply Centex Homes, Model 1577 A 6 1 - _ .lJob Reference.(optional) .._ 10-5-14 6.500 s Feb 5 2007 Mi :ek Industries, Inc. Fri Oct 12 08:13:24 2007 ROW . 10-5-1 9-0-0 9-0-0 -- —i LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.45 Vert(LL) -0.0 2-4 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1,25 BC 0.30 Vert(TL) -0.135 2-4 >514 180 BCLL 10.0 Rep Stress Incr YES WB 0,00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 20 lb LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=186/Mechanical, 2=359/0-7-8, 4=56/Mechanical Max-Horz2=110(LC 3) Max Uplift3=-125(LC 3), 2=-263(LC 3) Max Grav3=186(LC 1), 2=359(LC 1), 4=113(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-3=-54/38 BOT CHORD 2-4=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 125 lb uplift at joint 3 and 263 lb uplift at joint 2. LOAD CASE(S) Standard Jo Truss Truss Type Qty _ Ply Centex Homes, Model 1577 A X07-471 E7U MONO TRUSS 9 1 ...-_ _. _ Job Reference (optional) Universal Forest Product, Inc. E359, Ver� FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. I I 81 b2007 Pagel cale = 1:13.9 LI-I-IV 18-8-0 4x4 = 18-8-0 6-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in floc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.49 Vert(LL) -0.06 2-4 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.32 Vert(TL) -0.15 2-4 >471 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 ------- Code FBC2004/TP12002 ----------- (Matrix) Weight: 20 lb LUMBER BRACING ----- ---- ---- -- TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=194/Mechanical, 2=353/0-3-8, 4=58/Mechanical Max Horz2=185(LC 3) Max Uplift3=-151(LC 3), 2=-229(LC 3) Max Grav3=194(LC 1), 2=353(LC 1), 4=116(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-3=-79/61 3OT CHORD 2-4=0/0 VOTES 1) Wind: ASCE 7-05; 130mph.(3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. ?) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. ' t) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 151 lb uplift at joint 3 and 229 lb uplift at joint 2. -OAD CASE(S) Standard 1-JO6 fi-pe. Centex Homes, Model 1577 A Q" Q I X07-471 Fo`l� FLOOR " F2 �T I Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967 6.500 s Feb 5 2007 MlTek Industries, Inc. Fri Oct 12 08:13:25 Z007 Page-e-1 0-1-8 2-6-0 .2-0-0 II 2-5-4 - I 0�v I Sc e: 1/4"=l'i 3x5 2x3 11 2x3 11 2x3 11 46 = 3x6 F.P= 2x3 11 2x3 11 2x3 11 2x3 11 2 3 4 1 5 6 7 a 9 10 11 1� 13 14 150 W 2 1W 1 1 W V.W 2 1 W 5 1 1 W 2 29 Fit 28 25 24 23 22 21 20 19 18 17 16 3x5 2x3 11 4x6 -- 3x7 3x6 FP- 3x6 12-6-8 22-6-12 9-0-0 12-3-8 1 20-6-12 21-6-12 22 27-10-8 9-0-0 6-8-8 1-0-0 1-0-0 3-7-0 0-'1'8 8-0-4 1-0-0,1-0-10" 5-2-4 0-1-8 0-1-8 [-5:0--1-8,0-.--0-0]----- ,[9:0-2-4.Edge], [12:0-1-8, Edge]. [13:0-1-8,0-0-0], [15:0-1 -8, Edge],. [17:0-1-8, Edge], [18:0-1-8, Edge], [19:0-2-12,E( 23.0-1-8,Edgel, [26:0-1 8,0-1-81, [27:0-1-8.0-1-8], [28;0-1-8,0-1-81, [29:0-1-8,0-1-8] LOADING (pso SPACING 2-0-0 CS1 DEFL in (loc) I/defi L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.86 Vert(LL) -0.16 23-24 >919, 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.93 Vert(TL) -0.23 23-24 >633 240 BCLL 0.0 Rep Stress Incr YES WB 0.30 Horz(TL) 0.04 16 n/a n1a BCDL 5.0 Code FBC2004/TPI2002 (Matrix) Weight: 146 lb LUMBER BRACING TOP CHORD .4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS (Ibtsize) 16=762/0-6-12, 21=1683/0-5-8, 25=579/0-6-12 Max Grav 16=782(LC 4), 21 =1683(LC 1), 25=658(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 25-26=-103/0, 26-27=-10310, 1-27=-1 03/0, 16-28=-10710, 28-29=-1 0710, 15-29=-107/0, 1-2=0/0, 2-3=-1 300/0, 3-4=-1 30010, 4-5=-1158/169, 5-6=-1 158/169, 6-7=0/959, 7-8=01962, 8-9=01962, 9-10=-1 528/0, 10-11 =-152810, 11-12=-1746/0, 12-13=-1746/0, 13-14=-1746/0, 14-30=0/0, 15-30=0/0 BOT CHORD 24-25=01891, 23-24=-169/1158, 22-23=-16911158, 21-22=-6261338, 20-21=01735, 19-20=0f735, 18-19=0/1 722, . I 17-18=0/1 746,,16-17=011096 NEBS 4-23=-256/0, 5-22=-45210, 12-1 8=-1 80/0, 13-17=-309/0, 7-21=-236/0, 6-22=0/1213, 6-21 =-841/0, 9-21=-1553/0, 9-1 9=0/1003, 10-19=-203/0, 11-19=-350/0, 11-18=-62/284, 2-25=-104010, 2-24=-1 91477, 3-24=-340/0, 4-24=0/491, 14-16=-1279/0, 14-17=01763 VOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 20 and 8. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. -OAD CASE(S) Standard i Job I Truss i Truss Type - Qty Ply CeoFex Homea,,Model 1577 A i X07-471 I F02 I FLOOR 9 1 - .. - - , __ _ Job Reference (optional) . _ _. - Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:25 2007 Page 1 1 I ' 0-1-8 I 2-6-0 1-2-8 2-0-0 0-7-4 II ...... --- -.._._ . _.... ..--._ .- -I I — I Scale = 1:21.0 2x3 11 3x4 3x4 3x4 2x3 II 3x4 == 2x3 II 46 = 3x4 11 1 2 3 4 5 6 7 3x4 '= 3x5 = 2x3 11 3x5 = 9-0-0 9-0-0 7-8-8 8-8-8 12122-4 _—_11W-8 6-8-8 1-0-0 1-0-0 3-5-12 0-0-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.83 Vert(LL) -0.12 10-11 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.73 Vert(TL) -0.17 10-11 >816 240 BCLL 0.0 Rep Stress Incr YES WB 0.21 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code FBC2004ITP12002 (Matrix) Weight: 67 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 12=653/0-6-12, 8=653/Mechanical FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 12-13=-102/0, 13-14=-102/0, 1-14=-102/0, 1-2=0/0, 2-3=-1285/0, 3-4=-1285/0, 4-5=-1141/0, 5-6=-1141/0, 6-7=0/0 BOT CHORD 11-12=0/884, 10-11=0/1141, 9-10=0/1141, 8-9=0/929 WEBS 4-10=-171/0, 5-9=-497/0, 2-12=-1031/0, 2-11=0/468, 3-11=-300/0, 4-11=-97/311, 7-8=-111/0, 6-8=-1077/0, 6-9=0/690 NOTES 1) Unbalanced floor live loads have been considered for this design. 2)-Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job Truss iTruss Type �� pty Ply Centex Homes, Model 1577 A X07-471 F03 FLOOR 9 1 _ _ - _ ____ —____ Job gpference_(o�ona�,_____ Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967 T 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:25 2007 Page 1 0-1-8 2-6-0 2-5-4 2-1-4 2-4-4 L..I 1. _.-.._. I ...._. Scale = 1:26.4 2x3 11 Px4. _ _ .. - _........... _ .._._._.. 15-3-4 -- - — — --- 3x4 3x5 '- 2x3 11 3x4 = 2x3 II 1 2 3 4 5 3x4 � 3x4 II 6 7 c a 3x4 -= 3x4 = 2x3 II 3x6 = 3x5 = 9-0-0 6-3-1 2 7-5-4 9-0-0 5-2-4 54112 7-3-12 ,, 15-3-4 1513-8 5-2-4 0-1-8 1-0-0 1-0-0 0-1-8 7-10-0 0-0-4 Plate OffsetsL,Y)_-L-1-8,Edge] [4:0-1-8 Edge] [6.0-1-12 Edge] [8.0-2-0 Edge] [10.0-1-8 0-0-0] [11.0-1-8 Edge] [13.0-1-8 0-1-8] [14.0-1-8 0-1-8] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.77 Vert(LL) -0.25 9-10 >730 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.96 Vert(TL) -0.33 9-10 >547 240 BCLL 0.0 Rep Stress Incr YES WB 0.27 Horz(TL) 0.03 8 n/a n/a BCDL 5.0 ------------------------ Code-FBC2004ITP12002 -- (Matrix) — Weight: 80lb LUMBER BRACING --- - TOP CHORD A X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS (lb/size) 12=823/0-6-12, 8=823/Mechanical FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 12-13=-110/0, 13-14=-110/0, 1-14=-110/0, 1-2=0/0, 2-3=-1912/0, 3-4=-1912/0, 4-5=-1874/0, 5-6=-1874/0, 6-7=0/0 BOT CHORD 11-12=0/1166, 10-1 l=0%1912, 9-10=0/1912, 8-9=0/1185 WEBS 3-11=-340/0, 2-12=-1360/0, 2-11=0/907, 4-10=-148/22, 7-8=-108/0, 6-8=-1375/0, 6-9=0/803, 5-9=-327/0, 4-9=-359/167 NOTES 1) Unbalanced floor live loads have been considered for this design. 2)-Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Job Truss., lfrus-s-fyp-e- Q--i Ply-- Centex Grmes,Mode1177A 5_.. _____...__.__._. _....... _.. i j X07-471 F04 FLOOR 1 1 � U_. niversal Forest Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:25 2007 Page 1 I I i 0-1-8 I I I 2-6-0, ..__ .- 1-10-2 1-10.2 2x3 11 3x4 c- 3x4 -, 1 10 Ci 3x4 = 9-0-0 Scale = 1:15.t 3x4 = 2x3 II 3x4 = 2x3 II 2 3 4 5 9-2-4 3x4 = 1 9-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Lld PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.30 Vert(LL) -0.01 7 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.24 Vert(TL) -0.05 6-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.14 Horz(TL) 0.01 6 n/a n/a BCDL 5.0 Cade FBC2004/TP120b2 (Matrix) Weight: 50 Ib LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 8=492/0-6-12, 6=492/Mechanical FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 8-9=-104/0, 9-10=-104/0, 1-10=-104/0, 5-6=-104/0, 1-2=0/0, 2-3=-735/0, 3-4=-735/0, 4-5=0/0 BOT CHORD 7-8=0/615, 6-7=0/615 WEBS 2-8=-718/0, 4-6=-718/0, 3-7=-139/0, 2-7=0/154, 4-7=0/154 NOTES 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard WE r Job Truss Truss Type Qty Ply Centex Homes, Model 1577 A ! X07-471 F05 FLOOR 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:26 2007 Page 1 ' I 018 Scale = 1:13.3 3x4 = 3x4 - 3x4 = 3x4 = 2x3 II 1 2x3 11 2 3 4 _T---__.._....... _-..- --_-- -- _ - _ - --- - -,--_ .� _--_- - --- - - ----- _ W2 / W3 W2 i r 3x4 = 6 9-0-0 3x4 = 7-9-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d TCLL 40.0 Plates Increase 1.00 TC 0.30 Vert(LL) -0.01 6 >999 480 TCDL 10.0 Lumber Increase 1.00 BC 0.21 Vert(TL) -0.08 5-6 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(TL) 0.01 5 n/a n/a BCDL 5.0 Code FBC2004/TPI2002 (Matrix) LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD BOT CHORD 4 X 2 SYP No.2 WEBS 4 X 2 SYP No.2 BOT CHORD REACTIONS (lb/size) 7=41410-6-12, 5=414/Mechanical FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 7-8=-108/0, 8-9=-108/0, 1-9=-108/0, 4-5=-105/0, 1-2=0/0, 2-3=-511/0, 3 BOT CHORD 6-7=0/511, 5-6=0/479 WEBS 2-7=-593/0, 3-5=-559/0, 2-6=0/28, 3-6=0/39 NOTES 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each to attached to walls at their outer ends or restrained by other means. 3) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 3x-,9-:9-0 PLATES GRIP MT20 244/190 Weight: 43 lb Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. Job Truss I Truss Type X07471 F06 FLOOR j Universal Forest Product, Inc. b59, Vero Beach, Ff. 32967 ' 2 2 01IF, 3x4 - 3x4 3x4 = 1 9-0-0 2 3x4 -- 4x6 11 33x4 = 4 5 LOADING (psf) SPACING 2-0-0 TCLL 40.0 Plates Increase 1.00 TCDL 10.0 Lumber Increase 1.00 BCLL 0.0 Rep Stress Incr NO BCDL 5.0 Code FBC2004/TP12002 LUMBER TOP CHORD 4 X 2 SYP N0.2 SOT CHORD 4 X 2 SYP No.2 WEBS 4 X 2 SYP No.2 1 Oty Ply Centex Homes, Model 1577 A 1 1 j ....----•- 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:26 2007 Page 1 C11f8 Scale = 1: 3x4 = 6 7 8 9 10 11 - - ----- T�- _- --- - ---- _-- V 3 x. �X_Y...'3"h�_z._±:..:r;.._:C�.r.._�i 5x5 = 3x4 12-1-8 CSI DEFL in (loc) I/defl L/d PLATES GRIP TC 0.67 Vert(LL) n/a n/a 999 MT20 244/190 BC 0.02 Vert(TL) n/a n/a 999 WB 0.28 Horz(TL) -0.00 12 n/a n/a (Matrix) Weight: 68 lb r BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 22=225112-1-8, 12=258/12-1-8. 19=2320/12-1-8, 21=533/12-1-8, 20=354/12-1-8, 18=1159/12-1-8, 17=1170/12-1-8, 16=1158/12-1-8, 15=1158112-1-8, 14=1171112-1-8. 13=1201/12-1-8 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 22-23=-219/0, 23-24=-219/0, 1-24=-219/0, 11-12--254/0, 1-2=-17/0, 2-3=-17/0, 3-4=0/46, 4-5=0/46, 5-6=0/46, 6-7=0/46, 7-8=0/46, 8-9=0/46, 9-10=0/46, 10-11=0/46 BOT CHORD 21-22=0/0, 20-21=0/17, 19-20=0/17, 18-19=-46/0, 17-18=-46/0, 16-17=-46/0, 15-16=-46/0, 14-15=-46/0, 13-14=-46/0, 12-13=0/0 WEBS 4-19=-2222/0, 2-21=-533/0, 3-20=-343/0, 5-1 8=-1 149/0, 6-17=-115710, 7-16=-114510, 8-15=-1144/0, 9-14=-1158/0, 10-13=-1119/0, 3-19=-11310, 1-21=0/24, 11-13=-83/0 NOTES 1) All plates are 2x3 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fattened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2438 lb down at 4-0-12 on top chord. The design/selection of such connection device(s) is the responsibility of others. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 12-22=-10, 1-4=-328(F=-228), 4-11=-860(F=-760) Concentrated Loads (lb) Vert: 4=-2438(F) Job Truss - -Truss Type - - - '- " C1ty •Ply Centex Homes, Model 1577 A X07-471 F07 FLOOR 1 1 Job Reference,(cptional)._ .. __... .--. _ .. Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 6'Y007 MiTek Industries, Inc. Fri Oct 12 08:13:26 2007 Page 1 I 0-1 1 F 8 0 Scale = 1:26.41 3x5 II 3x4 3x4 _ 5x6 II 5x5 1 2 3 4 5 6 7 8 9 10 11 12 13 2x3 II 3x4 - 2x3 II 2x3 11 4x6 II 06 = 2x3 II 2x3 II 2x3 II 2x3 II 06 = 2x3 II 2x3 11 9-0-0 15-2-8 Plate Offsets (X,Yj: [1:Edge,0-1-8J, [2:0-3-O,Edge], [3:03-O,Edge], [4:0-3-0,Edge], [5;0-3-0,Edge], [6:0-3-0,Edge], [7:0-3-0,Edge], [8:0-3-0,Edge], [9:0-3-0,Edge], 110:0-3-0 Edge], [11:0-3-0,Edge], [12:0-3-0,Edge], [13:0-1-8,Edge], [14:0-1-8,Edge], [15:0-1-8,Edge], [20:0-1-8,Edge], [25:0-1-8,Edge], [27:0-1-8,0-1-8], LOADING j--- ----- -------- - -- (psq SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.52 Vert(LL) n/a n/a 999 MT20 2441190 TCDL 10.0 Lumber Increase 1.00 BC 0.05 Vert(TL) n/a n/a 999 BCLL 0.0 Rep Stress Incr NO WB 0.27 Horz(TL) 0.00 20 n/a n/a BCDL 5.0 Code FBC2004/TPI2002 (Matrix) Weight: 101 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 4 X 2 SYP No.2 except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 26=386/15-2-8, 14=302/15-2-8, 21=2208/15-2-8, 23=428/15-2-8, 25=376/15-2-8, 24=428/15-2-8, 22=600/15-2-8, 20=1769/15-2-8, 19=1180115-2-8, 18=1177/15-2-8, 17=1194/15-2-8, 16=1123115-2-8, 15=1606/15-2-8 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 26-27=-380/0, 27+28=-380/0, 1-28=-380/0, 13-14=-296/0, 1-2=-18310, 2-3=-18310, 3-4=-18310, 4-5=-183/0, 5-6=-183/0, 6-7=0/203, 7-8=0/203, 8-9=0/203, 9-10=0/203, 10-11=0/203, 11-12=0/203, 12-13=0/203 BOT CHORD 25-26=0/0, 24-25=0/183, 23-24=0/183, 22-23=01183, 21-22=0/183. 20-21=0/183, 19-20=-203/0, 18-19=-203/0, 17-18=-203/0, 16-17=-203/0, 15-16=-203/0, 14-15=0/0 NEBS 6-21=-2205/0, 4-23=-414/0, 2-25=-538/0, 3-24=-416/0, 5-22=-590/0, 7-20=-1174/0, 6-20=-699/0, 8-19=-1167/0, 9-18=-1164/0, 10-17=-1180/0, 11-16=-1110/0, 12-15=-1382/0, 1-25=0/256, 13-15=-291/0 NOTES 1) All plates are 2x5 MT20 unless otherwise indicated. 2) Gable requires continuous bottom chord bearing. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2753 lb down at 6-0-12 on top chord. The design/selection of such connection device(s) is the responsibility of others. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 14-26=-10, 1-6=-328(F=-228), 6-13=-875(F=-775) Concentrated Loads (lb) Vert: 6=-2753(F) Job Truss �Tr­sstype p{y I Ply Centex Homes, Model 7577 A I X07-471 I FG1 FLOOR 1 J_ob Reference (optional)_ Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 6,500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:27 2007 Page 1 . 1-2-4... F _ �.-3-p- i 1-0-14 1 11-0-�4 i _-i Scale = 1:29,f 4x6 = 5x8 = 4x4 = 4x4 = 4x4 = 4x4 _ 5x5 = 5x8 = 4x6 = 1 2 3 4 5 6 7 8 9 5X1O 9-0-0 4x6 = IY IJ CV 4x4 = 4x4 = L 1 I I 4x6 = IV 5x10 = 9-0-0 0- 12 3-4-12 5-10-12 9-7-0 12-1-0 14-7-0 17-11-0 __17-�1-12 0-0-12 3-4-0 2-6-0 3-8-4 2-6-0 2-6-0 3-4-0 0-0-12 ate Offsets (X,Y): [1_0_2 4,0-2-0], [3:0-1-12.0-2-0], [7:0-2-0,0-3.0], [9:0-2-4,0-2-0], [10:0-2-12,0-2-8], [11:0-1-8,0-2-0], [12:0-1.12,0-2-0]. [15:0-4-0,0-5-4], [16:0-1-8,0-2-0], LOADING 40.0 SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.97 Vert(LL) -0.30 13 >673 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0,86 Vert(TL) -0.46 13-14 >438 240 BCLL 0.0 Rep Stress Incr NO WB 0.61 Horz(TL) 0.07 10 n/a n/a BCDL 5.0 Code FBC2004ITP12002 (Matrix) Weight: 322 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-4-4 cc purlins. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 *Except* W1 2X8SYP SS, W1 2X8SYP SS REACTIONS (lb/size) 17=6629/0-6-12, 10=681210-4-0 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/0, 2-3=-12216/0, 3-4=-1875310, 4-5=-21621/0, 5-6=-21624/0, 6-7=-1894610, 7-8=-12210/0, 8-9=0/0 BOT CHORD 17-18=0/6725, 16-18=0/6725, 16-19=0/15594, 15-19=0/15594, 14-15=0/20333, 13-14=0/21621, 13-20=0120421, 12-20=0/20421, 12-21=0/15689, 11-21=0/15689, 11-22=0/6722, 10-22=0/6722 WEBS 2-16--0/7896, 3-16=-4858/0, 3-15=0/4543, 4-15=-2272/0, 8-11=017892, 7-11=-5003/0, 7-12=0/4684, 6-12=-2120/0, 6-13=0/1730, 5-14=-65/0, 5-13=0/5, 4-14=0/1877, 1-17=-102/0, 9-10=-101/0, 2-17=-8928/0, 8-10=-8924/0 NOTES 1) 3-ply truss to be connected together with 10d (0.131"&') nails as follows: Top chords connected as follows: 2 X 4 -1 row at 0-9-0 oc. bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 cc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc, 2 X 8 - 2 rows at 0-9-0 cc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 1) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 641 lb down at 2-1-8, 810 lb down at 2-1-8, 641 lb down at 4-1-8, 810 lb down at 4-1-8, 641 lb down at 6-1-8, 810 lb down at 6-1-8, 641 lb down at 8-1-8, 810 lb down at 8-1-8, 641 lb down at 10-1-8, 810 lb down at 10-1-8. 641 lb down at 12-1-8, 810 lb down at 12-1-8, 641 lb down at 14-1-8, 810 lb down at 14-1-8, and 641 lb down at 16-1-8, and 810 lb down at 16-1-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. -OAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 10-17=-10, 1-9=-100 Concentrated Loads (lb) Vert: 15=-1451(F=-641, B=-810) 12=-1451(F=-641, B=-810) 14=-1451(F=-641, B=-810) 18=-1451(F=-641, B=-810) 19=-1451(F=-641, B=-810) 20=-1451(F=-641, B=-810) 21=-1451(F=-641, B=-810) 22=-1451(F=-641, B=-810) :Job jTruss Truss Type Qty Ply X07-471 FG2 FLOOR Centex Homes, Model 1577 A , 1 2 Job Reference (optional) _.- _---_._ ... _._.... __. j Universal Forest Product, Inc. E359, Vero Be ' 6. FI. 32967 - -- - - -- - - - -- - 2-4-4 2-0-0 8.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:27 2007 Page 1 _ 2-0-2 -9-1 2-7-10 2-7.0 2-7-10 � I - L --- - - - 12_0_12.- - - 4x4 II 4x4 '= 7-8-8 1 __.d 5 Scale: 1 /4"=1 9-1-8 4x4 II ------dx4-----------4x4-11-_----._-.-� 7-1-2 6 7 10 11 12 13 26 25 24 23 22 21 20 19 18 17 16 15 14 4x4 II 4x4 = 4x4 II 5x10 = 4x4 II 4x4 = 4x4 II 9-0-0 9-0-0 9-0-0 F------ 9=1-8 12-3-8 - 27-7-8 - -I 9-1-8 3-2-0 15-4-0 Offsets (X,Y): [2.0-2-010-0-8], [4:0-2-4,0-2-0], [5:0-2-4,0-2-0), [6:0-3-0,Edge], [9:0-2-4,0-2-0], [10:0-2-4,0-2-0], [12:0-2-0,0-0-0], [16:0-2-0,0-0-8], [17:0-2-4,0-2-6 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.56 Vert(LL) -0.09 16-17 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.55 Vert(TL) -0.13 16-17 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.23 Horz(TL) 0.01 14 n/a n/a BCDL 5.0 Code FBC2004lrP12002 (Matrix) Weight: 286 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2 X 4 SYP No.2 except end verticals. WEBS 2 X 4 SYP No.2 `Except' BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. W1 2 X 6 SYP SS, W1 2 X 6 SYP SS, W5 2 X 8 SYP SS W52X8SYPSS,W12X6SYPSS,W12X6SYPSS W52X8SYP SS, W52X8SYP SS REACTIONS (lb/size) 26=465/0-5-4, 14=799/0-5-4, 21=265210-5-8 Max Grav26=559(LC 2), 14=847(LC 3), 21=2652(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-26=-567/8, 13-14=-932/0, 1-2=-934/78, 2-3=-934/78, 3-4=-856/429, 4-5=-416/701, 5-6=0/2665, 6-7=0/2665, 7-8=0/2665, 8-9=-133/670, 9-10=-1828/0, 10-11=-2446/0, 11-12=-1733/0, 12-13=-1733/0 BOT CHORD 25-26=0/102, 24-25=-78/934, 23-24=-78/934, 22-23=-429/856, 21-22=-701/416, 20-21=-670/133, 19-20=-670/133, 18-19=0/1828, 17-18=0/2446, 16-17=0/1733, 15-16=0/1733, 14-15=-86/0 WEBS 5-22=0/900, 10-17=0/358, 7-21=-411/0, 2-25=-338/18, 1-25=-136/1001, 3-24=-90/97, 5-21=-2614/0, 12-15=-559/0, 13-15=0/1983, 11-16=-309/0, 11-17=0/817, 8-19=01786, 9-18=0/604, 4-23=0/327, 10-18=-910/0, 3-23=-622/0, 9-19=-1984/0, 4-22=-756/0, 8-21=-2600/0 r NOTES i 1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Webs connected as follows: 2 X 8- 2 rows at 0-9-0 oc, 2 X 6- 2 rows at 0-9-0 oc, 2 X 4- 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) All plates are 46 MT20 unless otherwise indicated. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) CAUTION, Do not erect truss backwards. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 459 lb down at 9-1-8, and 459 Ito down at 19-11-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plt) Vert: 14-26=-10, 1-13=-100 Job Truss Truss Type i X07-471 IFG2 FLOOR Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 22=-459(F) 17=-459(F) --_. _ Qty � Ply Centex Homes, Model 1577 A 1 I Job Reference -(optional__ _ I 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:27 2007 Page 2 Job Truss Truss Type X07-471 FG3 FLOOR i Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 1 4x4 Qty Ply Centex Homes, Model 1577 A 2 1 .... Job Reference (optional) 6.500.s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:27 2007 Page 1 { .-_Z_8-12---------- 2 04 II I ' Scale = 1:8 F 4x� fi--- ------ 3-3-12 3-8-4 3-3-12 0-4-8 Plate Offsets (X,. : E2 dge 0-3-8] LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.30 Vert(LL) -0.01 34 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.23 Vert(TL) -0.01 3-4 >999 240 BOLL 0.0 Rep Stress Incr NO WB 0.02 Horz(TL) 0.00 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 20 lb LUMBER BRACING TOP CHORD 2 X'4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-8-4 oc purlins, BOT CHORD 2 X 6 SYP SS except end verticals. WEBS 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied. or 10-0-0 oc bracing. W12X4SYP No.3 REACTIONS (lb/size) 4=421/Mechanical, 3=386/0-3-8 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-4=-151/0, 1-2=0/0 BOT CHORD 4-5=0/0, 3-5=0/0 WEBS 2.3=-151/0, 1-3=-0/0 NOTES 1) Refer to girder(s) for truss to truss connections. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 475 lb down at 1-6-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 4) In the LOAD CASES) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 3-4=-10, 1-2=-100 Concentrated Loads (lb) Vert: 5=-475(F) Job i Truss I Truss Type qiy Ply Ceniex Homes, Model 1577 A I X07-471 FG4 FLOOR 1 3 Job Reference.(optional) . .. . ... ... ... Universal Forest Product, Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:28 2007 Page 1 1-6-4 1-4-8 1-8-8 2-4-9 2-1-13 2-3-10 2-3-10 2-1-13 2-4.9 1-8-8 1-4-8 [--------{ F-------I f----I I------------i F--------I F---------i I----------i i----I I--------i F-----i F-----i Scale: 1 /4"=1 46 I.5-1 -k�1�' 5x7 =. - 44 -1-4 3x6= - -3(4 3x4 =-4x6 =' 3x8 = 2x5 II 5x10 = 4x6 = 3x�--- _-3x>{s{ = 5'I�4 '4x8 1 30 2 3 4 5 6 7 8 9 10 11 12 f3 14 - 15i 29 28 27 26 25 2432 23 22 21 20 31 19 18 17 16 4x6 II 4x6 =- 4x6 = 3x5 = 3x4 = 3x6 = 5x16 = 8x16 = 3x6 = 3x4 = 3x5 = 3x5 = 3x4 II 5x10 MT18H= 9-0-0 9-0-0 0- 12 16-5-14 27-7-8 _ 0-2-12 -- _ 16-3-2 11-1-10 Plate Offsets (X,Y): [ ::0-3-4, --2-4],, [2 00-2-0,0-1-12], 15:0-1-12.0-1-8], (7:0-3-0,0-1-8), [9:0-3-4,0-2-8], [12:0-2-12,0-1-8], [14:0-2-4,0-1-8], [15:0-2-4,0-2-0 - [18:0-2-4,0-1-81 [20:0-2-12,0-1-81,[21:0-5-4,0-4-121,[22:0-4-0,0-2-81 [26.0-2-4,0-1-81,[27:0-2-0 0-1-121[28:0-1-12 0-2-01 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES TCLL 40.0 Plates Increase 1.00 TC 0.92 Vert(LL) -0.22 24-26 >875 480 MT20 TCDL 10.0 Lumber Increase 1.00 BC 0.70 Vert(TL) -0.33 24-26 >581 240 MT18H BCLL 0.0 Rep Stress Incr NO WB 0.92 Horz(TL) 0.04 21 n/a n/a BCDL 5:0 Code FBC2004/TPI2002 (Matrix) Weight: 552 lb LUMBER TOP CHORD 2 X 6 SYP SS BOT CHORD .2 X 6 SYP SS WEBS 2 X 4 SYP No.2 *Except* W1 2 X 8 SYP SS, W1 2 X 8 SYP SS, W8 2 X 6 SYP SS W10 2 X 6 SYP SS, W9 2 X 4 SYP No.1, W9 2 X4 SYP No.1 REACTIONS (lb/size) 29=620210-5-4, 16=1871/0-5-4, 21=16847/0-4-0 Max Upliftl6=-564(LC 2) Max Grav29=6429(LC 2), 16=2973(LC 3), 21=16847(LC 1) 9-0-0 [ 17:0-2-4,0-1-8], GRIP 244/190 244/190 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-29=-5667/0, 15-16=-2606/503, 1-30=-8964/0, 2-30=-8964/0, 2-3=-15940/0, 34=-19129/0, 4-5=-18523/0, 5-6=-1284310, 6-7=-12843/0, 7-8=-1326/2962, 8-9=-132612962, 9-10=0114740, 10-11=-2903/8554, 11-12=-2903/8554,12-13=-8718/3772,13-14=-6915/2102,14-15=-3963/981 BOT CHORD 20-21=-8554/2903, 20-31=-3772/8718, 19-31=-3772/8718, 18-19=-2102/6915, 17-18=-981/3963, 16-17=-160/853, 28-29=0/1845, 27-28=0/8964, 26-27=0115940, 25-26=0/19129, 24-25=0/19129, 24-32=0/18523, 23-32=0/18523, 22-23=0/12843, 21-22=-14740/0 WEBS 12-19=-1253/1108, 3-27=-5094/0, 13-18=-1859/842, 4-26=-1962/0, 2-28=-5002/0, 1-28=0/8353, 14-17=-2294/591, 15-17=-964/3649, 14-18=-138413646, 2-27=018616, 3-26=0/3726, 8-22=-1808/0, 13-19=-1952/2107, 7-23=0/3115, 5-24=0/734, 10-20=0/3176, 9-21=-10047/0, 4-24=-1172/0, 5-23=-6789/0, 7-22=-13294/0, 12-20=-9015/0, 10-21 =-1 1415/0, 9-22=0/15267 NOTES 1) Special connection required to distribute web loads equally between all plies. 2) 3-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2 X 8•- 2 rows at 0-9-0 oc, 2 X 6 - 3 rows at 0-4-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 4 - 2 rows at 0-4-0 oc, Except member 13-18 2 X 4 - 1 row at 0-9-0 oc, member 4-26 2 X 4 - 1 row at 0-9-0 cc, member 2-28 2 X 4 - 1 row at 0-9-0 oc, member 1-28 2 X 4 - 1 row at 0-9-0 oc, member 14-17 2 X 4 -1 row at 0-9-0 oc, member 15-17 2 X 4 - 1 row at 0-9-0 oc, member 14-18 2 X 4 -1 row at 0-9-0 cc, member 2-27 2 X 4 -1 row at 0-9-0 cc , member 3-26 2 X 4 - 1 row at 0-9-0 cc, member 8-22 2 X 4 -1 row at 0-9-0 oc, member 13-19 2 X 4 - 1 row at 0-9-0 oc, member 24-5 2 X 4- 1 row at 0-9-0 oc, member 10-20 2 X 4- 1 row at 0-9-0 cc, member 24-4 2 X 4 -1 row at 0-9-0 oc, member 5-23 2 X 4- 1 row at 0-9-0 oc, member 7-22 2 X 4- 1 row at 0-9-0 cc, member 12-20 2 X 4- 1 row at 0-9-0 oc, member 10-21 2 X 4- 1 row at 0-9-0 oc, member 9-22 2 X 4- 1 row at 0-9-0 oc, 2 X 6- 2 rows at 0-9-0 cc. 3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply -to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 4) Unbalanced floor live loads have been considered for this design. 5) All plates are MT20 plates unless otherwise indicated. 6) Bearing at joint(s) 21 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. U,Rrat4ideaftohtiw1 zal connection (bv others) of truss to bearing plate capable of withstanding 564 lb uplift at joint 16. 9 Job Homes, Is 0 i y- Centex Model "--'l 8 �7 k X07-47 . 1 . FG4 FLOOR 31Job Reference Trus ----------------- Universal Forest Product, Inc. E359, Vero Beach, Fl. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:28 2007 Page 2 NOTES 8) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 9) CAUTION, Do not erect truss/' backwards. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2268 lb down at 3-11-4, and 2762 lb down at 21-8-4, and 328 lb down at 1-0-0 on top chord, and 360 lb down at 9-1-8, and 360 lb down at 19-11-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate lncrease=1.00 - Uniform Loads (M Vert: 1-30=-220(F=-120), 3-30=-320(F=-220), 3-12=-883(F=-783), 12-15=-320(F=-220), 16-22=-10, 22-29=-10 Concentrated Loads (lb) Vert: 12=-2762(F) 3=-2268(F) 30=-328(F) 31 =-360(B) 32=-360(B) Job Truss J Truss Type - ijty - ply 1*deiniex—Ho me- s, Model 1577 A X07471 K01 JACK 2 1 - - _ - . Job Reference joptiona).. _. _ 10-7-12 - ._..._ Universal Forest Product, Inc. E359, VerQJt ach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries,'Inc. Fri Oct 12 08:13:28 2007 Pia I -1-5-0 I 3-1-.1.. .... L 5-7-2 1-5-0 3-1-1 2-6-1 Scaled 1:Ik 1 /i !. 2 i 4x4 = 9-0-0 6 LOADING (pso SPACING 2-0-0 CSI TCLL 20.0 Plates Increase 1.25 TC 0.45 TCDL 15.0 Lumber Increase 1.25 BC 0.30 BCLL 10.0 Rep Stress Incr NO WB 0,00 BCDL 10.0 Code FBC2004/TP12002 (Matrix) 3.54 12 T1 B1 5 7 4 10-7-1 9-0-0 2-6-1 DEFL in floc) I/deft L/d PLATES GRIP Vert(LL) -0.04 2-4 >999 360 MT20 244/190 Vert(TL) -0.10 2-4 >613 180 Horz(TL) -0.00 3 n/a n/a Weight: 19 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-7-2 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=182/Mechanical, 2=365/0-4-4, 4=62/Mechanical Max Horz2=137(LC 3) Max Uplift3=-116(LC 3), 2=-296(LC 3) Max Grav3=182(LC 1), 2=365(LC 1). 4=123(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/27, 2-5=-47/0, 3-5=-38/43 BOT CHORD 2-6=0/0, 6-7=0/0, 4-7=0/0 ,. NOTES 1),Wind: ASCE'7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60, 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections, 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 116 lb uplift at joint 3 and 296 lb uplift at joint 2. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 8 lb down and 2 lb up at 4-2-15, and 8 lb down and 2 lb up at 4-2-14 on top chord, and 21 lb up at 1-4-15, 21 lb up at 1-4-15, and 17 lb down at 4-2-15, and.17 lb down at 4-2-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 2-4=-20 Concentrated Loads (lb) Vert: 5=-15(F=-8, B=-8) 6=21(F=10. B=10) 7=-17(F=-8, B=-8) Job i Truss I Truss Type X07-471 K02 JACK Universal Forest Product, Inc. E859, Very-ee�nch, FI. 32967 1-5-0 1-5-0 dty Ply Centex Homes, Model 1577 A I I1 1 optlonal) 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:28 2007 "Red 3-4-14 5-7-2 3-4-14 2-2-4 Scale = 1:11.7 3 �J� 2.12 F12 6 _ __ "\/ 5 T1 2 7 9-0-0 3-4.14 LOADING (psf) SPACING 2-0-0 CSI TCLL 20.0 Plates Increase 1.25 TC 0.29 TCDL 15.0 Lumber Increase 1.25 BC 0.30 BCLL 10.0 Rep Stress Incr NO WB 0.00 BCDL 10.0 Code FBC2004ITP12002 (Matrix) LUMBER TOP CHORD 2.X 4 SYP N0.2 BOT CHORD 2'X 4 SYP N0.2 REACTIONS (lb/size) 3=145/Mechanical, 2=313/0-4-15, 4=62/Mechanical 'Max Horz2=81(LC 3) Max Uplift3=-95(LC 3), 2=-301(LC 3) Max Grav3=145(LC 1), 2=313(LC 1), 4=124(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/16, 2-5=-28/0, 5-6=-23/0, 3-6=-20/20 BOT CHORD 2-7=0/0, 7-8=0/0, 4-8=0/0 131 8 4 9-11-1 9-0-0 5-7-2 2-2-4 DEFL in (loc) Udefi L/d PLATES GRIP Vert(LL) -0.04 2-4 >999 360 MT20 244/190 Vert(TL) -0.11 2-4 >592 180 Horz(TL) -0.00 3 n/a n/a Weight: 19 lb BRACING TOP CHORD Structural wood sheathing directly applied or 5-7-2 oc purlins BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 95 lb uplift at joint 3 and 301 lb uplift at joint 2. 6) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 47 lb up at 2-1-7, 47 lb up at 2-1-7, and 7 lb down at 4-2-15, and 7 lb down at 4-2-15 on top chord, and 11 lb up at 2-1-7. 11 lb up at 2-1-7, and 16 lb down at 4-2-15, and 16 lb down at 4-2-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-70, 2-4=-20 r Concentrated Loads (lb) Vert: 5=94(F=47, B=47) 6=-14(F=-7, B=-7) 7=11(F=5, B=5) 8=-16(F=-8, B=-8) iJob Truss Truss Type aty Ply Centex Homes, Model 1577 A X07-471 K4U MONO TRUSS 1 1� Job Reference (optional)_.____ Universal Forest Product, Inc. E359, Vero Beach, FI.32967 18 8 0 6,500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:29 2007 Page 1 4x4 5 - 3 1E�8 18 -0 i--- —. 1-2-2 i 1-5-5 3-2-3 1-2-2 0-3-4 _ 1-8-14 LOADING (psf) SPACING 2-0-0 TOLL 20.0 Plates Increase 1.25 TCDL 15.0 Lumber Increase 1.25 BCLL 10.0 Rep Stress Incr NO BCDL 10.0 Code FBC2004/TP12002 LUMBER TOP CHORD 2 X 4 SYP No.2 BOT CHORD 2 X 4 SYP No.2 WEDGE Left: 2 X 4 SYP No.2 Scale = 1:7 CSI DEFL in (loc) I/deft L/d PLATES GRIP TC 0,17 Vert(LL) -0.00 1-3 >999 360 MT20 2441190 BC 0.06 Vert(TL) -0.01 1-3 >999 - 180 WB 0.00 Horz(TL) -0.00 2 n/a n/a (Matrix) Weight: 11 lb BRACING TOP CHORD Structural wood sheathing directly applied or 3-2-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=101/Mechanical, 3=25/Mechanical, 1=124/0-6-7 Max Horz 1=55(LC 3) Max Uplift2=-89(LC 3), 3=-7(LC 3), 1=-99(LC 3) Max Grav2=101(LC 1), 3=49(LC 2), 1=124(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-4=-27/0, 2-4=-34/27 BOT CHORD 1-5=-0/O, 3-5=-0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 89 lb uplift at joint 2, 7 lb uplift at joint 3 and 99 lb uplift at joint 1. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 16 lb down and 34 lb up at 1-3-10 on top chord, and 44 lb up at 1-3-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-70, 1-3=-20 Concentrated Loads (lb) Vert: 4=-4(B) 5=11(B) Job i Truss Truss Type X07-471 K6U I MONO TRUSS Universal Forest Product, Inc. E359, Vero Beacq,%_82967 i . ._ __ 5-5-12 18-8-0 4x6 II 1-2-2 0-3-4 j Qty Ply Centex Homes, Model 1577 A I1 1 �. Job Reference (optional)._- 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:29 2007 Page 1 4-0-7 EM LOADING (psi) SPACING 2-0-0 CSI DEFL in (loc) 1/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.66 Vert(LL) 0.13 1-3 >478 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.48 Vert(TL) -0.14 1-3 >436 180 BOLL 10.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 18 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-5-12 oc purlins. SOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE Left: 2 X 4 SYP No.2 REACTIONS (lb/size) 2=207/Mechanical, 3=103/Mechanical, 1=407/0-6-7 Max Horz 1=93(LC 3) Max Uplift2=-171(LC 3), 3=-59(LC 3), 1=-423(LC 3) Max Grav2=207(LC 1), 3=135(LC 2), 1=407(LC 1) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-4=-48/0, 4-5=-48/0, 2-5=-56/53 BOT CHORD 1-6=0/0, 6-7=0/0, 3-7=0/0 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 171 lb uplift at joint 2, 59 lb uplift at joint 3 and 423 lb uplift at joint 1. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 16 lb down and 34 lb up at 1-3-10, and 10 lb down and 4 lb up at 4-1-9, and 26 lb down and 34 lb up at 4-1-9 on top chord, and 44 lb up at 1-3-10, 210 lb down and 326 lb up at 1-3-10, and 16 lb down at 4-1-9, and 15 lb down at 4-1-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-70, 1-3=-20 Concentrated Loads (lb) Vert: 4=-4(F) 5=-35(F=-26, B=-10) 6=-199(F=11, B=-210) 7=-15(F=-7, B=-8) Job Truss Truss Type IX07-471 K7U MONO TRUSS Universal Forest Product, Inc. E359, Ve'�h, FI. 32967 -1-5-0 1-5-0 3-6-11 -_. _....__..........—..---- - rOtyPly Centex Homes, Model 1577 A 1 1 20-3-121 _ 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:29 2007 %4-6 i --------i-- 5-7-14 - --- --- -- —I 2-1-3 a..+.,.m w kpbl) ar-Zinv z-u-u ubi UEPL In (loc) I/deft Ud TCLL 20.0 Plates Increase 1.25 TC 0.26 Vert(LL) -0.04 2-6 >999 360 TCDL 15.0 Lumber Increase 1.25 BC 0.26 Vert(TL) -0.08 2-6 >759 180 BCLL 10.0 * Rep Stress Incr NO WB 0.02 Horz(TL) 0.00 6 n/a n/a BCDL 10.0 I Code FBC2004/TPI2002 (Matrix) LUMBER TOP CHORD 2 X 4 SYP No.2 BOTCHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 4=87/Mechanical, 2=25710-5-11, 6=129/Mechanical Max Horz 2=111(LC 3) :Max Uplift4=-77(LC 3), 2=-244(LC 3). 6=-11(LC 3) Max Grav4=87(LC 1), 2=257(LC 1), 6=142(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/28, 2-3=-175/16, 3-4=-27/19 BOT CHORD 2-6=-53/147, 5-6=0/0 WEBS 3-6=-165/60 Scale = 1:11 PLATE5 GRIP MT20 244/190 Weight: 23 lb BRACING TOP CHORD Structural wood sheathing directly applied or 5-7-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 3) All plates are 44 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 4, 244 lb uplift at joint 2 and 11 lb uplift at joint 6. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-70 Trapezoidal Loads (plo Vert: 2=-4(F=33, B=33)-to-4=-99(F=-15, B=-15), 2=-O(F=10, B=10)-to-5=-28(F=-4, 6=-4) IJob Truss - Truss Type ---- -- qty - - pjy - Centex Homes, Model 1577 A X07471 K8 MONO TRUSS 2 1 - - -- - - - - - --- - --- - Job Reference o tionalZ - - -- -..... _.---tII.5.35- i Universal Forest Product, Inc. ��, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:1329 2007 PM-0 1-5-0 5 1 15 8 2 - l_ ..." 9-0-0 2.12 12 8-5-1 3-3-2 Scale = 1:16.4 4 3 7 65 1 10-5-15 9-0-0 5-1-15 B-4-6 8-5 1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.27 Vert(LL) -0.02 2-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.31 Vert(TL) -0.06 2-7 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.17 Horz(TL) 0.01 5 n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) ,n/a Weight: 33 lb LUMBER TOP C BRACING HORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS Jlb/size) 4=182/Mechanical, 2=391/0-10-10, 5-322/Mechanical Max Horz2=110(LC 3) Max Uplift4=-129(LC 3), 2=-299(LC 3), 5=-89(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP'CHORD 1-8=0/13, 2-8=0/13, 2-3=-946/281, 3-4=-35/24 BOT CHORD 2-7=-342/912, 6-7=-342/912, 5-6=0/0 WEBS 3-7=0/218, 3-6=-953/358 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. i) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 4, 299 lb uplift at joint 2 and 89 lb uplift at joint 5. 3) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). -OAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-8=-70 Trapezoidal Loads (plf) Vert: 8=0(F=35, B=35)-to-4=-147(F=-39, B=-39), 2=-2(F=9, B=9)-to-5=-42(F=-11, B=-11) ;Job iTruss Truss Type X07.471 I K9U I MONO TRUSS Universal Forest Product, Inc.1F83ft Vero Beach, FI. 32i967 i 1 -1-5-0 T-. 4 3 7 3.54 [ 12 2 18-8-0 Qty Ply Centex Homes, Model 1577 A 2 1 Job Reference (optional), 21 1.12 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:29 2007 7 4-2-6 Scale = 1:1 4 65 21-1-12 18-8-0 ----- -- 8--iT13 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Lid PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0,40 Vert(LL) 0.02 7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.31 Vert(TL) -0.06 6-7 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.21 Horz(TL) 0.01 5 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 36 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP N 2 o. REACTIONS (lb/size) 4=230/Mechanical, 2=404/0-5-11, 5=285/Mechanical Max Horz2=191(LC 3) Max Uplift4=-175(LC 3), 2=-284(LC 3), 5=-74(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/28, 2-3=-759/184, 3-4=-66/48 BOT CHORD 2-7=-298/708, 6-7=-298/708, 5-6=0/0 WEBS 3-7=0/212, 3-6=-743/313 NOTES 1) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 4x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 4, 284 lb uplift at joint 2 and 74 lb uplift at joint 5. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-70 Trapezoidal Loads (plf) Vert: 2=-4(F=33, B=33)-to-4=-148(F=-39, B=-39), 2=-O(F=10. B=10)-to-5=-42(F=-11, B=-11) Job ITruss I Truss Type X07-471 V4 VALLEY Ur�i�e)slaVorest Product, Inc. E359, Vero Beach, FI. 32967 Oty Ply Centex Homes, Model 1577 A 1 1 op al) 6.500 s Feb 5 2007 MiTek Indusfies, Inc. Fri Oct 12 08:13:30 2007 Page 1 2-0-12 19-11-0 5.00 F 12 2-0-12 2 Scale = 1:6.-1 4-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 15:0 Lumber Increase 1.25 BC 0.08 Vert(TL) n/a n/a 999 BCLL 10:0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 11 Ito LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-1-8 cc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS (lb/size) 1=120/4-1-8, 3=120/4-1-8 Max Upliftl=-55(LC 3), 3=-55(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-136/84, 2-3=-136/84 BOT CHORD 1-3=-60/112 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 44 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 3) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 55 lb uplift at joint 1 and 55 lb uplift at joint 3. _OAD CASE(S) Standard ;Job Truss Truss Type Oty Ply Centex Homes, Model 1577 A X074171 V8 IVALLEY 1 1 Job Reference (optional_.. ... _ nyrf orest roduct. Inc. E359, Vero Beach, FI. 32967 6.500 s Feb 5 2007 MiTek Industries, Inc. Fri Oct 12 08:13:30 2007 Page 1 i l 4.0-12 . 8.1_g 4-0-12 4-0-12 Scale = 1:13.: 2 19-1-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/clef! Ltd PLATES GRIP — TCLL 20.0 Plates Increase 1.25 TC 0.18 Vert(LL) n/a n/a 999 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.11 Vert(TL) n/a n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) 0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 25 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=149/8-1-8, 3=149/8-1-8, 4=303/8-1-8 Max Upliftl=-79(LC 3), 3=-79(LC 3), 4=-105(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-54/33, 2-3=-54133 BOT CHORD 1-4=0/17, 3-4=0/17 WEBS 2-4=-219/130 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; C-C Interior(1); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3)'Thls truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 4x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 1, 79 lb uplift at joint 3 and 105 lb uplift at joint 4. LOAD CASE(S) Standard St. Lucie Cotinty Building and Zoning Department 2300 'Virginia Avenue Fort Pierce, FL 34982 772-462-1553 Design Certification for Wind Load Compliance '1'his Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applieutionS Tor building permits involving, the construc;lion of new residencc (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidemial structure, T16S Certi liktdion shall not apply to interior renovations (provided that no structural walls, columns or other similar component is being effected) and certain other !oi!Tor buildipr permits. For finiher assistance, please contact the Build!n, Insp!:ction Office at462-i553 orc162-2f72_ Pro'ect Name Sheet Andress MORNINGSEDE q43�%� __ T � Office Use Only Pcrmit Numbcr T peen .:uiC TXpe Construction Tv ie + -- LOT QL BLS cA Certification Statement: I certify that, to the best of my knowledge and bt;li4f, these plans and specifications have been designed to 1, comply with the applicable structural portion ofthe Building Codes currently adopted and enforced by Si- Lucie County. I also certify that structural elements dcpictc td on these plans provide adequate resistance to the wind loads and forces specified by ourrcnl code provisions. Design Parameters and Assumptions Used: (PIease check or complete the appropriate box.) I. Florida 13uildina Code 2004 edition ASCE 7-�� 2. );nilding Design is (cnectc one) Enclosed -V Partially Enclosed Open Building 3. Building IIeight: 24 +-111 4; Wind Speer) Used in Building Design: t -in 3 second bust 5. Wind Exposure ClaSSifieatio n (refer to exposure tables in Building? Code identified in Line 91): li 6. Average Wind Velocity Pressure on Exterior Traces of Structure 25.74 PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure N/A PSF 8. Importance/Use Factor (obtain from Building Code): 1.0 9. Loads. :floor 55 YS1' hoof/dead 25 PSI' Roof%live - Ala-1'SI+' 10. Were Shear Walls Considered for Structure (cltecicone): Yes ✓ No (ifNo, awach explanation) 11. Is a Continuous Load Path Provided check one): Yes ( ) No (if No, attach explanation) 12. Are Corttp(neni and Cladding; Detail Prim iile(1 (check one): Yes No _ _(if No, attach expl;tnafio11) 13, Minimum Soil Bearing Pressure: 2,500 PSF As witnessed by my seal, I hereby certify that the information included with this certification is ue and correct, to the best of my knowledge and belief. Name: SCOTT R. BRENNAN Design Firm; BlRENNAN ENGINEERING, INC. Cer1i(iCwion H; 51311. �CELSaHe 6 -Dat.c. SI-CCDV Form N 02U-00 rcv. 81HOH X�1N30 05:60 (NOH)800z-81-S3�'