Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
OFFICE USE 6NLY: Date: ,�,) ©�-� Fee Due: Receipt# Permit # O; d;? ALL INFO MUS BE COMPLETE & FILLED IN T BE ACCEPTED m St. Lucie County Building and Zoning 9>t01?7e;) YL- 2300 Virginia Avenue /70 �vClo �rr . P Ft. Pierce, FL 34982-5652 SCANNED .. BY 772-462-1553 AW ,St. Lucie County f 0.70 APPLICATION FOR A - ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 1900 Trowbridge Road Fort Pierce, FL 34995 2. S/DNAME: Trowbridge Acres SITE PLAN NAME: Allen Residence 3. PROPERTY TAX ID #: 2213-504-0008-000-3 4. LEGAL DESCRIPTION (attach extra sheets if necessary): Trowbridge Acres S/D Lot 8 less W 5 FT for RD R/W (9.30 AC) 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. NO. NO. 8 .61 10 PARCEL SIZE: ACRES/SQ FT. e1.3 LOT DIMENSIONS LIDS, IDS' SETBACKS (ACTUAL) FRONT: BACK:Cat2.5RIGHT SIDE:--I-Q,-- LEFT SIDE: 1-11 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab . WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X RIX POOL ENCLOSURE N ❑ NEW U EXISTING { X 30 13 w ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X TOTAL SQUARE FOOTAGE OF CONSTRUCTION ► 5 Ste{ 12. VALUE OF CONSTRUCTION: $ q 5C�o . o0 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 2119107 d OWNER INFORMATOOl Arthur R. Sanrira Allen ` NAME: ADDRESS: 9604 Enclave Circle CITY: Port St, Lucie STATE: FL ZIP 34986 PHONE (DAYTIlVIE): (7 7 2) 8 7 8— 7 7 5 2 email: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTMIE): (_) CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: BUSINESS NAME: Pioneer Screen Cc Inc II QUALIFIER'S NAME: Michael J. Newman A1)nRRSS- 1682 SW Biltmore Street CITY: Port St. Lucie STATE: PHONE(DAYTIME): (772 )340-4393 FAX NO. ARCHITECT/ENGINEER: BDQ, Inc ADDRESS: 1950 NE 170TH Avenue ST. LUCIE COUNTY CERT #: 4763 FL 340-4626 ZIP 34984 email: PioneerscreenCamsn.com CITY: Williston STATE: FL ZIP 3 2-6 9 6 PHONE (DAYTIlVIE): (352) 529-0080 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks including'front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFFICE USE ONLYa ...ZONING r. 'Ift fi a yf� �,; t SECTION 13 TOWNSHIP �5 S RANGE 3 g � MAP NO. �1 ` ZONING LAND USE LOT CVG % Additional Permits Yes no Cj�J REPORT CODE t-1 BIMS FEE MISC FEES TOTAL FEES :.;BUILDING; &ZONING REVIEW,, Ki�N� , REVIEWS ZONING ZONING PLANS MISC. VEGETATION VALUE OF CONSTRUCTION REVIEWED BY EXAMINER USING ICC TABLE DATE COMPLETE D c� ® ?' �/ D� o,�• INITIALS �e ebiirf_,�J_19_09�1 PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: A-2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4t' wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 40' wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: r This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE ' TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU P-A-YING—T-W-IC--E—FOR—IMPROVEMENTS-TO- YOUR- PROPERTY IF-YOU-INZBND—TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand, that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contracto / O er Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is ' de a condition to withstand the uplift and weight of the aluminum st ture/�nd said structure will not exceed the fo rint the structure that was in existence prior to removal by the sto;; �l7 / SIGNATURE STATE OF FLORIDA COUNTY O)S--LLL ' o The foregoing instrument was acknowledged before me thisa day off r 20CFS�by U&pe ( jl . , who is personally known to me or who has produced t ,2n ��� f--� F as identification. of Notary 9"1 (SEAL)A&I My com� Oo3544i3 ,01 MOes2e.20od IMPORTANT NOTICES: SIGNATURE STATE OF FLORIDA COUNTY OF �� The foregoing instrument was acknowledged before me thisQ day often, 20(�by H iCnaP j Nntxmn , who is personally known to a or who has produced — s-identification. Signature of Notary (SEAL) d OWMA (�tjMy CommissM W354413 Expires October 29, 2008 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. F / 04/25/2008 08:48 77? 04626 PIONEER SCREEN CO II PAGE 01 'OTICE OF COMMENCEMENT PERMIT NO.____—�_- TAX FOLIO NO.w221350400080003_ 11 M- FRY, Jr., CLERK OF THE CIRCUIT COURT -------- �.__ SAINT LUCIE COUNTY STATE OF FLORIDA COUNTY OF --St. Lucre County___` FILE 0 3183426 om,,2oaS et 06;45AM OR ODOK 2951 PAGE 2035. 2a35 pep TyPe: NO RECORDING_ $10.00 The undersigned hereby gives notice that impro-ement will be made to certain real property, and in _ accordance with Chapter 713 Florida Statutes, the following information is provided in the Notice of _ l Commencement: Legal Description: (include street address if available � ~ }: _L07 8, TROWBRIDCE ACRES, AS RECORDED IN PLAT BOOK 4Z, PAGE 23, PUBLIC RECORDS OF ST. LUCIE COUNTY, Fl, _1900 TROWBRIDGE ROAD FORT FIERCE, FL 34995_. General Description of Improvements: ENC.OSURE�� Owners Name: -ARTHUR AND SANDEE ALLEN__ Address: -9604 ENCLAVE CIRCLE PORT ST. LUCIE, FL 34986__.__, __�_ Owners Intrest in Site of Improvement: Fee Simply - - Fee Simple Title Holder ( if other thamowner Contractor: PIONEER SCREEN CO, II 1682 SW IIILTMORE STREET PORT ST. LUCIE, Surety: -----N/A FL 34984 Amount of Lender ( Persons or Entities making a loan for the Improvement ): Address: _ ------ ------------------------ -.___ _ -------------- Name and Address of persons within the State of Aorida designated by the owner as person upon whom notices or other documents may be served Rs provided by Florida Statutes Section ® 713.13(1)(a)(7): p � ei LL In addition to himself, Owner designates the f01101ifing to receive a copy of the Llenor's Notice U as provided in Section 713.13 (1) (b ), Florida Statues: sv Q Expiration date of notice of commencement ( the explra:ion date is 1 year from the date of recording unless a different date Is specified.—_ WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOI ICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB 51TE BEFORE THE FIRST INSPECTION, IF YOU INTEND TC OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR 40TICE OF COMMENCEMENT. OWNER -------h,wr �! . A11e� wrier PR OWNERSAUTHORIZEO OFFICER/DIRECTOR/MANAGER/PARTNER PRINT NAME AND PROVIDE TITLE State of Florida, County of Acknowledged before me this day of �+ , 2008 by as--------- . ------------ o lI , personally known acF `ra*icaiiv*+- ~�PATRIMAM.GIUNTA *=M D0060Q�OS l,�(� E�e� Sf,10IM10 I WwN d ft (004324IN41 Notary Public ;;;;,,,N,,,,M, , t+;;M,.06 � pe d, printed, or Typed Name of Notary verification pursuant to Section 92.525 Florida Statues. Under penalties of perjury. I declare that I have read the forego ng and that the facts stated In it are true to the best of my Icnowledge and belief. — signature of Natural Person signing above �� ,,�urirti. I/OtPrr.` Code Compliance `Division 2300 Virginia Avenue Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce Issued: Job Location: 1900 TROWBRIDGE RD Permit Type: Pool Enclosure Job Description BUILDING PERMIT Conf #: 852 Permit #: SLC- 0803-0301 City: FORT PIERCE INSTALLATION OF A POOL ENCLOSURE 44' X 30' (POOL PERMIT 0705-0249) Page 1 S/D Lot: 8 Block: Parcel: 2213-504-0008-000/3 Contractor NEWMAN MICHAEL J PIONEER SCREEN COMPANY INC II (772) 340-4393 1682 SW BILTMORE ST PORT ST LUCIE, FL 34984 Property Owner ARTHUR A ALLEN 9604 ENCLAVE CIR Property Owner SANDRA ALLEN Setbacks Left: PORT ST LUCIE, FL 34986 9604 ENCLAVE CIRCLE PORT ST LUCIE, FL 34986 Number of Units: 1.00 Minimum Floor Elevation: Right: Floors: 1 (772) 878-7752 (772) 878-7752 Front: Rear: Zoning: AG-5 Buildings: 1 Square Footage: 0.00 Flood Map: 165F Flood Zone: X Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Ljl 1l /Z) R Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. r� Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://Stiucieco.gov/ce Date: 11 April 2008 Job Address: 1900 TROWBRIDGE RD Received By: vorreyej Paid With: CK Paid By: PIONEER SCREEN CO Building Receipt Receipt#: 0000062099 'ermit Number: SLC- 0803-0301 Amount: $130.00 �redit Card Number: Check Number: 48699 Sign: > co- , Code Compliance Division 2300 Virginia Avenue Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax:(772) 462-2522 a. Fees/Payments Address,, '1900 '=1TROWBRIDGEIL City i State / zip . PR = FL w 34'945 x ` Parcel # ' 2213 504-0008=00013 - 1urisdiction CT( . uture LandUse Agriculture'-5- Subdivision 2213504 PPfmlt Tana. !fool Enclosure Other • ALUMINOM ;STRUCTURE• Stones `1 itomatic Sprinkle[ System? o *• Pay Code Type •;•. Account •;• 'Quantity Amount 'Date Posted Paid?, ' " 'Fee Permi726 06-Permit Fee = Pool Enclosure 491 2415 322000 200 $75.00 04i11/2008 w, � PI6nR738 06-Plan R6i6W -Pool/Spa Enclosur 481,241.5,322000 200 $50.00"�;",.. _ ` 04/11/2008 Yes • BI 06-BI 491 415 32050 00 04/11/2009 YesMS651 PermJ726 -- 06-Permit Fee, ,`Pool Enclosure 491 2415 322000 200 m $75 00 -° ' ` ., " 0.4/1,112008 Yes ` ' i i 3ate;,Entered 04/11/2008 t Date Paid 04/11/200 Entered By ciciok Historical `Receipt # Amounts Date Posted` 0000062099 $130.00 04/11/2008 Paid By PIONEER SCREEN CO •; .Payment Type CK •;• - = Check (CK); Cash `(CA) Check 48699 .•. Mastercard (MC); Visa (VS),Fee Waived (FIYW), Refund (RF) Credit: Cai&Numb�er Reversal,(RV) dredit CaYd'Authorization I§sued To: PIONEER SCREEN CO Received By vorreyej Date Paitl 04/11/2008 03/19/2008 11:42 7723404626 PIONEER SCREEN CO II PAGE 02 ; ST. L,UCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT 2300IRRGINIA AVENUE FORT PIERCE, FL 34982-W32 561-462,IM FILLED LANDS AFFIDAVIT I the undersigned, am the owner of this following described property, 1G UQ l f%fl Arc :C10k 51 _ ?X - \ 'cor-- - Decr�- c i _ �- v (tax IDAegal des( ription/address) for which I have applied to St. Lucie Co inty for a Final Development Permit. In accepting this Final Development Permit, BP Number I acknowledge that as owner of the above described propert r, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Cocie, I shall be responsible for assuring adequate drainage so that the immediate community M LL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this property, St. Lucie County is neither obliged nor liable to provide for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. Property owner PrOP86 Owner . Date (Print) (Signgtrtre) STATE OF FLORIDA, COUNTY OFIEA- SWORN TO AND SUBSCRIBED BEFORE ME 'THIS —i2.AY OF- , 20-9, BY-,i.>A. c � ., %A ' - I IS PERSONALLY KNOWN TOM R N. ""18...u.........,.u........ u..n...... ,,PATj§" M. GIUNTA SIGNATURE OF NOTARY l YPE OR PRINT NAME OF NOTARY P COMO Dxsoseoa 1 QTARY PUIC BLTITLE -ouasneRAOMMISSION NUMBER F +w.i `Aw".wh'?..i SLCCDV FORM NO.: of i-on "),TICE OF COMMENCEMENT PERMIT NO.__A"=V 3c�_ TAX FOLIO NO.__2213504,000.800.03_-__—__-- STATE OF FLORIDA COUNTY .O.F'__St. Lucie County__=_�____ HE .cZC:;ji �10_PIY The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713 Florida Statutes, the following information is provided in the Notice of Commencement: Legal Description: ( include street address if available ): -LOT 8, TROWBRIDGE ACRES, AS RECORDED IN PLAT BOOK 42, PAGE 23, PUBLIC RECORDS OF ST. LUCIE COUNTY, FL --- —------------- — ---------- --------- --___ _1900 TROWBRIDGE ROAD FORT PIERCE, FL 34995-------- —_—------------------- —_— ----- ... General Description of Improvements: ENCLOSURE Owriers Name: _ARTHUR AND SANDEE ALLEN ---------------- —_—------- —____ Address: _9604 ENCLAVE CIRCLE PORT ST. LUCIE, FL 34986_______________________ Owners Intrest in Site of Improvement: Fee Simple Fee Simple Title Holder ( if other than owner) --- —---------- —---------------- ----- —_______ Contractor: PIONEER SCREEN CO. II 1682 SW BILTMORE STREET PORT ST: LUCIE, FL 34984 Surety: --------NSA--------- -vmount-o Bon Lender (Persons or Entities making a loan for the Improvement): ----------------------------------- Address: Name and Address of persons within the State of Florida designated by the owner as person upon whom notices or other documents may be served as provided by Florida Statutes Section 713.130)(a)(7): In addition to himself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1) (b ), Florida Statues: a Property Appraiser - St.Lucie C, --nty, FL Page 1 of 1 PROPERTY RECORD CARD Arthur A Allen Record: 1 of 1 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification \,,4CIE C Site Address: 1900 TROWBRIDGE RD ParcelID: 2213-504-0008-000-3�GZ Sec/Town/Range: 13:35S:38E Account #: 152026 h Map ID: 22/13X Land Use: • UNCLSFD ACRG Zoning: �A City/Cnty: ST. LUCIE COUNTY Ownership and Mailing Legal Description Owner: Arthur A Allen Sandra MA Allen TROWBRIDGE ACRES S/D LOT 8-LESS W 5 FT FOR RD R/W- (9.30 Address: 9604 Enclave Cir AC) (OR 2631-1787) Port St Lucie FL 34986 Sales Information Assessment Final Total Land and Building Date Price Code Deed Book/Page 2007 FV: 297600 Land Value: 297600 Acres: 9.3 7/27/2006 360000 00 WD 2631 / 1787 Assessed: 297600 Building Value: 0 10/1/2004 260000 00 WD 2079 / 2806 Ag.Credit: 0 Finished Area: 0 SgFt 9/30/2003 93400 00 WD 1814 / 0540 Exempt: 0 5/9/2002 362900 02 WD 1526 / 1196 Taxable: 297600 Taxes: 5620.72 BUILDING INFORMATION No Sketch No Image AVailable Available Exterior Features View: - RoofCover: RoofStruct: - ExtType: - YearBlt: Frame: - Grade: - EffYrBlt: PrimeWall: - StoryHght: - No.Units: SecWall: - Interior Features BedRooms: 0 Electric: - PrmintWall: - FullBath: 0 HeatType: AvgHt/FI: 1/213ath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth 1 9900-UNCLSFD ACRG N -Acres 9.3 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.pasle.org/pre.asp?prclid=221350400080003 3/28/2008 Friday, Mar 28, 2008 09:14 AM ti Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp:/Istiucieco.gov/ce Review Comments PROPERTY INFORMATION Address: 1900 TROWBRIDGE RD City / State / Zip: FORT PIERCE FL 34945 Parcel # : 2213-504-0008-000/3 Jurisdiction: St. Lucie County Zoning: AG-5 Lot # : 8 Block: APPLICATION INFORMATION Permit Number: 0803-0301 Activity. Type: Other Permit Type: Pool Enclosure CONTRACTOR INFORMATION Contractor Name: NEWMAN MICHAEL J Business Name: PIONEER SCREEN COMPANY INC II Business Addr: 1682 SW BILTMORE ST City / State / Zil PORT ST LUCIE, FL 349E Page 1 Owner(s): ARTHUR A ALLEN SANDRA ALLEN Application Type: Building Permit w/o subs Other Activity: ALUMINUM STRUCTURE Stories: 1 Automatic Sprinkler System? ❑ Fax Number 772-340-4626 REVIEWS AND COMMENTS Review Type Status Reviewed By Front Counter Review Complete Audrey Humphrey Zoning Review Pending Jodee Vorreyer Date Started Date Complete Date Released 03/28/2008 03128/2008 03/3112008 03/31/2008 1 Comment NEED A SURVEY OR PLOT PLAN TO SCALE. CAN'T READ THE MEASUREMENTS AROUND THE POOL. PLEASE REVISE S TRANSMISSION VERIFICATION REPORT TIME 03/31/2008 11:48 NAME FAX TEL SER.# BROH5J320634 DATEJIME 03/31 11: 48 FAX NO./NAME 93404626 DURATION 00: 00: 18 PAGE(S) 01 RESULT OK MODE STANDARD ECM Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462.2522 http:llstl u cieGo.govlce Review Comments PROPERTY INF_QRMA r10 Address_ 1900 TROWBRIDGE RD City 1 State 1 Zip: FORT PIERCE FL 34945 parcel # : 2213-504-0008-00013 Jurisdiction: St. Lucie County Zoning: AG-5 Lot#: 8 Block: APPLICAT70N INFORMATION permit Number: 0803-0301 Activity Type: Other Permit Type; Pool Enclosure CONTRACTOR 1NF._©RMA TION Contractor Name: NEWMAN MICHAEL J Business Name: PIONEER SCREEN COMPANY [NO II Business Addr: 1682 SW BIL,TMORE ST Page 1 Gwner(s): ARTHUR A ALLEN SANDRA ALLEN Application Type: Building Permit w/o sUbs Other Activity: ALUMINUM STRUCTURE stories: 1 Automatic sprinkler system? ❑ Fax Number 772.340-4626 City I State ! Zil PORT ST LUCIE, FL 349E REWEWS AND OOMMEN7S R vi Ravi d Front Counter Review Complete Audrey Humphrey Dat_=rtsd pate Complete Date.Releasad 0312812008 03125/2008 Iwelen Vnrrevar 02131/2002 C-4 of LL. I 1 6 of 0 0 a jce-oz LL. (L r- X Ld f-- 0 LP Ld at < U) 11 • c14 -i C3 v) (L af m: Z < m 0 0 c� &L9' lir 29 o .L9-8 c,'l co t sL9'017 ca U) cc 0 co of 1c, C14 co L SC9,0Z a; co < U- 'k "LN3 C13SOcIONd -1 0 n- c; SC9,zz IL Z: 0 , .9"L . . . ...... in n c; ul eq Z dy L sz IPZ 117Z • 03SOdobd rf MIN. SETBACK REQ. FRONT SIDES ab CNR SIDES Vi REAR 3b ZNG. A TECH: � z 1001 R/W CANAL NO. 56 SHEET 1 of 2 FND. #5 230.00' REBAR t r . LOT 7 ti OCCUPIED FF = 50.50' ��• f 1 I NOTE: NO CONFLICT BETWEEN LOTS FOR WELL & SEPTIC H 1� .I i N � U W LOT 6 " r OCCUPIED ) FF = 55.1' o N (; 101)l i 1' cow f 1 z d I cNi is 0 O j N I 0 z H J V 11J 1 RE FENCE 300.00' 416 4 W EXHIBIT 1,' IN PLACE FORM BOARDS TOP OF FORMS=55.74' 0 EXISTING WELL S0001311211E (M) S0000911011E (P) ALLEN RESIDENCE XXXX TROWBRIDGE RD FT. PEIRCE, FL. LEGAL DESCRIPTION LOT 8 TROWBRIDGE ACRES SUBDIVISION PLAT BOOK 42, PAGE 23 SAINT LUCIE COUNTY, FLORIDA 00 u4 qrt _ N a :-f U r rn u 00 z it 72' LOT 9 VACANT 72'' i I 38" -"- — EXHIBIT 2 38' I 'ROP SED POND -I B.M. #2 50.00' TOP OF REBAR WIRE FENCE YD! .,�__...__......,....._ 22.5.98' (M) 350.00' _(.P&M.i as 50.59' BENCHMARK = PAINTED ORANGE "X" ELEV. = 50.00' ASSUMED 50.00' B.M. Y �Nn K5 R&C ° 121 Ly'�_"E,.,,(P8M) 3Cx3r.99' ROAD � 51.75' SCALE 1" = 100' CHECKED BY is George Aylor, Jr. JOB NO. 3789-06 738 SW Colleen Ave. DRAWN BY G.A. FIELD BK. NO. Port St. Lucie, Florida 34983 REFERENCES FIELD WORK DATE 7-18-06 772-335-4403 FLOOD ZONE DATE 7-23-06 Office & Fax Number 1-8-07 FORMBOAR 01-15-07 ADD THREE SEPTIC AREA REVISED 1-29-07 SHOW ADDITIONAL T•I•E TO GUEST HOUSE AND MAIN USE RE 7_1 Win\. onnnn cunvCv n.l un 1&1 o nuc Or unIICC _..__... ..___ r- FND. 4x4 c6NC• MONUMENT DE51GN NOTE5: 1. ALL DIAGONAL BRACING SHOWN IN 50TH THE ROOF AND - WALLS SHALL 5E 2 x 2 x .093 TUBE MATERIAL. 2. -18 x 14 ME5H SCREEN 15 THE MAXIMUM ALLOWA5LE DENSITY FOR TH15 ENCLOSURE'S DE51GN, N 3. DOOR(6) MAY 5E PLACED INTO ANY 5CREEN WALL PANEL EXCEPT FOR TH05E THAT CONTAIN DIAGONAL BRACING, OVERALL DESIGN COMPLIES WITH THE 2006 ZD AMENDMENTS TO THE E.B.C. 2004 5UILDING CODE, FOR 140 MPH WINID LOAD (3-5ECOND GU5T), FOR EXP. CAT. "C" (NON-H.V.H.Z.). TH15 SYMBOL REPRE5ENT5 DIAGONAL r 0 WIND BRACING (IN BOTH THE ROOF AND WALLS), 2 x 2 x .093 TUBE MAIL. , ICI ;>�I� INSPECTIO14 FOR WAGOtIL UVI;II UTA V, Tj 'A 1AND DETAILS. 0 THIS SYMBOL REPRE5ENT5 BEAM SPLICE LOCATIONS � SIELE CcN�E� �E�TIDNS AND ALL �{9�i5EN CoN LS ARE j"f RESP®NS ®� DE, YviE ALDWINOl U ���TRA PIONEER SCREEN CO., 11 SCREEN ROOF ENGL05URE FOR: ALLEN RESIDENCE IX3 1'300 TROIUBRIDGE RD. FORT PIERCE, FLORIDA ro SHEET 1 OF 2 o E @ I e x in m rN - x 32' 6' MANSARD BEAM SPAN THESE ARE REQUIRED PLANS AND ALL PROPOSED WORK SUBJECT TO ANY CORRECTIONS BY FIELD INSPECTORS 30' ON MANSARD BEAM SPAN 2V ON MANSARD BEAM SPAN 22' 6' MANSARD BEAM SPAN MAYBE THAT NECESSARY 2 6' 6' m' >;' 3' >;' 3' 6' m' COMPLY IN ORDER ip EXIS71NCx 057 FASCIA WITH ALL APPLICABLE C®®g®, /xX,2 NN e 1 NN NN HVY I C14 x xq xq xq x `0 '"x clax Nv 9 �I � • � r4 X 'N m x m X cn X m N x � < iA I x x x x u —G _ 2xim" _n sr. LUC11: Sit I13UpIILDIINO ,qOr IFDAT42 O 3 � Y7 G �y Wei IFOR Q N �F� +- z EQ Q2 x Im i-Xc,Lu "qr0 m0 �+ iu5 P--Frq to px xq xq x xq x2 xq x3 x IUSTBE(�Ep� ���N �; F 3 1 WIL x 1mN � o N _ 2xim I z N Nq �q x x e `9 2xim poll= 1 x5 1 � 2 x 10 q2 x 5U % � O m��"-xl 0 m0 cn m0 x mq e �N •� �w x xq x LV xq x N xq x cv x x N WN 2x3xldlm L 110. 1 _ (010, 1 6' ON I v m' I x ---------- � X Q0 EXIST. C.B.6. ON C4 x x PRIVACY WALL a1.�ua�1� �0 C) m N 1t J' .cocol ce) n ° (D Z N O NoL9� o p'Nzli)l cLooO o i F LLQ d OwLL OZQa�oO"- � � noo J o N uj Q TLoU �Ldtnd co �p w w 2 x 5 S,M.B. UPRIGHT (TYPICAL) 2 x 2 x 3/1(o" ANGLE CLIP (2 - INCHES LONG), WITH (4) FOUR #12 TEKS INTO THE SIDE OF THE UPRIGHT, TYP. ONE ANGLE ON EACH SIDE OF EACH 2 x 5 UPRIGHT (ALL SCREEN WALLS) EXISTING C.B.S. PRIVACY WALL (TYPICAL) PIONEER SCREEN CO., II SCREEN ROOF ENCLOSURE FOR: ALLEN RESIDENCE 1900 TROWBRIDGE RD. FORT PIERCE, FLORIDA SHEET 2 OF 2 OVERALL DESIGN COMPLIES WITH THE 200(o AMENDMENTS TO THE F.B.C. 2004 BUILDING CODE, FOR 140 MPH WIND LOAD (3-SECOND GUST), FOR EXP. CAT. C (NON-H.V.H,Z,). OO EQUAL D 1 STANCE (4-INCH MINIMUM) x EQUAL D 15TANCE (4-INCH MINIMUM) 3/8" x 5" RED -HEAD "LDT" TAPCON, TYP. ONE IN EACH ANGLE CLIP (TWO PER EA. 2 x 5 UPRIGHT), THE SCREEN WALLS SHALL BE FA51RCATED SO THAT ALL CONCRETE ANCHORS ARE PLACED IN THE CENTER OF THE CBS WALL, AS SHOWN. 1 x 2 BASE SCREEN FRAME (TYPICAL) 6GREEN WALL UPRIG�4T _ TO = C.5.5. WALL DETAIL ° 0 co r Nco � co a a�o,- c\j ~- o " c p'CVwmo a O W a 0 Q00LL O 0El J 0 o Q g^L� r � o W IN (� ?�f ° �ZO=W _ :, DO W g L- - r LL FAI51zIGATION / INSTALLATION REQUIRED GUI[DEL.INES: NOTE: ANY JOBS THAT REQUIRE SITE -SPECIFIC DESIGN / ENGINEERING MUST BE SUBMITTED TO THE ENGINEER OF RECORD FOR SUCH DESIGN CONSIDERATION PRIOR TO THE JOB BEING PERMITTED, FABRICATED OR INSTALLED. LEAD-TIMES FOR SUCH WORK WILL DEPEND ON OUR CURRENT WORK LOAD AT ANY GIVEN TIME. THE ITEMS BELOW ARE NOT PERMITTED ON ANY ENCLOSURE WITHOUT SITE -SPECIFIC DESIGN 4 AUTHORIZATION FROM THE ENGINEER OF RECORD. I. NO SCREEN ROOF SEAMS SHALL BE LOCATED WITHIN 12-INCHES OF ANY OUTSIDE CORNER OF ANY WALL, FASCIA OR STRUCTURAL GUTTER. 2. NO CABLE BRACING SHALL BE USED ON ANY ENCLOSURE AT ANY TIME FOR THE RESISTANCE OF ANY IMPOSED DE51GN LOADING. 3. THERE SHALL BE NO SUBSTITUTION OF EITHER CONCRETE ANCHOR TYPE OR MANUFACTURER OTHER THAN THOSE SPECIFIED ON THESE ENGINEERED DESIGN DRAWINGS. 4. THERE SHALL BE NO SCREENING UTILIZED THAT 15 FINER THAN 18 x,14 MESH SCREEN WITHOUT SITE -SPECIFIC DESIGN (THAT SHALL -BE DONE PRIOR TO THE - JOB BEING FABRICATED OR INSTALLED) WITH JOB DRAWINGS BEARING THE ENGINEER OF RECORDS ORIGINAL SIGNATURE (IN BLUE INK) UNDER HIS EMBOSSED SEAL. 5. ALL SCREEN ROOF ENCL05URES MUST BE POSITIONED ON THE EDGES OF THE CONCRETE DECK 50 THAT THE OUTER SURFACE OF THE SCREEN FRAME 15 NO LESS THAT 2 3/4 - INCHES IN FROM THE EDGE, TO CREATE PROPER EDGE D15TANCE FOR THE SPECIFIED CONCRETE ANCHORS AT THE BASE OF EACH COLUMN. 6. ALL ROOF PURLINS IN THE ROOF AND CHAIR RAILS IN THE WALLS SHALL NOT EXCEED 8-FEET CENTER - TO - CENTER SPACING (SEE APPROPRIATE DETAILS ON OTHER SHEETS OF THIS DRAWING FOR SPECIFIED MATERIAL SIZES REQUIRED FOR ANY GIVEN APPLICATION. 1. NO SCREEN ROOF ENCLOSURE SHALL BE INSTALLED UTILIZING SEVEN-INCH STRUCTURAL GUTTER, AS IT IS NOT PERMITTED, OR STRUCTURALLY ADEQUATE UNDER THIS ENGINEERING, THE ITEMS BELOW MUST BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO MEASURING 4 LAYOUT, FABRICATION OR INSTALLATION FOR THE REQUIRED SITE -SPECIFIC DESIGN. I. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES ROOF BEAMS THAT EXCEED 40-FEET IN SPAN, AT ANY POINT ON THE ENCLOSURE. 2. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES WALL COLUMNS (UPRIGHTS) THAT EXCEED 12-FEET IN HEIGHT AT ANY POINT ON THE ENCLOSURE. 3. ANY ENCLOSURE THAT UTILIZES ANY CARRIER BEAM (A BEAM THAT ACTS AS SUPPORT FOR ANY OTHER SCREEN ROOF BEAM) AT ANY POINT ON THE ENCL.OLSURE. NO CARRIER BEAM SHALL BE PERMITTED TO BE MOUNTED TO THE FASCIA OF ANY HOST STRUCTURE (AS PRIMARY SUPPORT). 4. INSTALLATION OF ANY SCREEN ROOF ENCLOSURE ON AN EXISTING HOUSE FASCIA WHERE THE OVERHANG EXCEEDS 2-FEET. NOTE THAT IF THE EXISTING RESIDENCE WAS CONSTRUCTED UNDER ANY BUILDING CODE PRIOR TO F.B.C. 2001, THE JOB MAY REQUIRE FOURTH -WALL TYPE CAST., AS THERE IS NO WAY TO CERTIFY THE ABILITY OF A HOST STRUCTURE THAT WAS ONLY BUILT TO WITH- STAND 110 MPH WIND LOADS OR LESS, (AS WAS REQUIRED UNDER PREVIOUS BUILDING CODES) TO RESIST THE IMPOSED LOADS OF AN ENCLOSURE THAT 15 DESIGNED TO WITHSTAND THE LOADS IMPOSED UNDER THE 140 MPH WIND LOAD SPECIFIED IN THE CURRENT BUILDING CODE. SNAP / LAP JOINT CONNECTION NOTE: ALL FRAMING MEMBERS ON ANY ENCLOSURE THAT UTILIZE SNAP OR LAP JOINT IN THEM SHALL HAVE 12 TEKS INSTALLED THRU THE SNAP OR LAP CONNECTION AT 18 INCHES ON CNTR. (TYP). THESE TEK SCREWS ARE TO BE PLACED ON BOTH EDGES OF THE UPRIGHT (BOTH THE INNER AND THE OUTER EDGE) IN ALL CASES. THIS SPECIFICATION APPLIES TO UPRIGHTS AND BEAMS BOTH. MINIMUM FOOTER TAE3LE5 MONO MAX. BM, FOOTER SPAN 6'XS'WITH (U 050 CONT. UP TO 38' V x 12' WITH (U 050 CONT. UP TO 41' 10'x12'WITH (I) SO CONT. UP TO 48' 12' x 12' WITH (2) SO CONT UP TO 55' qMAk. BM.S 0 SPAN 12' x 12'WITH (2) w5a CONT. UP TO 30' 12' x 16' WITH 31' TO 39' (2) S5 GONT. 14' x I6' WITH 40, TO 44' (2) w50 CONT. 16' x 16' WITH 44' TO 52' rz) w5� coNr. IF A JOB EXCEEDS THESE PARAMETERS, THE FOUNDATION MUST BE SITE -SPECIFICALLY DESIGNED BY THE ENGINEER MONOLITHIC FTG. LOAD CAPACITIES ARE BASED ON A MIN. OF 3 FEET OF CONT. CONCRETE, 2,500 1-51 MINIMUM, W/ WIRE OR FIBERMESH REINFORCEMENT (P)ISOLATED FOOTERS MAY BE USED ON EDGE OF EXIST. CONC. SLAB OR UNDERNEATH THE PERIMETER OF BRICK PAVER DECK (ALL SIDES) THE ENGINEER OF RECORD WILL NOT BE ABLE TO CERTIFY THE STRUCTURAL INTEGRITY OF ANY EXISTING CONCRETE DECK / FOOTINGS THAT WERE INSTALLED WITHOUT PERMITS, AS THERE WOULD BE NO RECORDS TO VERIFY CONCRETE THICKNESS', FOOTER SIXES AND THE SIZE AND QUANTITY OF STEEL RE -BARS THAT WOULD BE REQUIRED UNDER THE CURRENT BUILDING GODS STANDARDS. SCREW SPACING AND EDGE DISTANCE SPEC.'S THIS TABLE 15 BASED ON THE PROPERTIES OF C-1022 LOW CARBON STEEL 5115 AND SELF -DRILLING (TEK) SCREWS, WHICH ARE AN INDUSTRY STANDARD SCREW. SCREW SIZE NOMINAL SCREW DIAMETER (IN.) MIN. EDGE D15TANCE MIN. CENTER -TO - CENTER DISTANCE 08 0.15(o 5/16' 1/16' #10 0.180 3/8, 1/2' #12 0.219 1/2' 5/8' #14 0.250 5/6' 3/4' INTERNAL -CONNECTION SPECIFICATION (UTILIZING SCREW BOSSES) ALL INTERNAL CONNECTIONS UTILIZING THE EXTRUDED SCREW BOSSES SHALL HAVE #10 SMS SCREWS, WITH A MINIMUM EMBEDMENT INTO THE SCREW BOSS OF 1 3/4" (UNLESS OTHERWISE SPECIFIED ON ANY CONNECTION DETAIL). ALL SCREW BOSSES IN A GIVEN EXTRUSION MUST BE FILLED (EXAMPLE: THE 3 x 3 x .010 CHAIR RAIL (MINIMUM SIZE) THAT HAS SIX SCREW BOSSES, MUST HAVE SIX OF THESE #10 SMS SCREWS INSTALLED AT EACH END OF THAT COMPONENT, AT EACH CONNECTION). SCREEN PANEL INSTALLATION SPECIFICATION: PLFASE NOTE THAT ALL SCREEN PANEL OPENINGS (BOTH ROOF AND WALLS) SHALL BE INSTALLED ON ALL FOUR SIDES WITH SPLINE (INDEP- ENDANT OF ALL SURROUNDING PANELS). THE ONLY FRAMING COMPONENTS THAT ARE NOT REQUIRED TO HAVE SPLINE INSTALLED IN THEM ARE ALL OF THE DIAGONAL WALL AND ROOF BRACING. CONCRETE ANCHOR SPECIFICATIONS: ALL CONCRETE ANCHORS SPECIFIED ON THIS DETAIL SHEET ARE MANUFACTURED BY 'RED HEAD' ANCHORING SYSTEMS, AS ALL LOAD CAPABILITIES ARE BASED ON TEST DATA FURNISHED BY RED HEAD IN THEIR PRODUCT AND RESOURCE BOOK. NO SUBSTITUTIONS OF ANY OTHER MANUFACTURER'S CONCRETE ANCHORS IS PERMITTED WITHOUT SUBMITTAL OF THE COMPANY'S TEST DATA (TO VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN, SIGNED AND SEALED LETTER OF AUTHORIZATION FROM THE ENGINEER OF RECORD. ANY UNAUTHORIZED ANCHOR SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH THIS DESIGN, THE ANCHORS TO BE USED FOR APPLICATIONS SPECIFIED IN THIS ENGINEERING DESIGN PLAN ARE AS FOLLOWS: 1/4' DIA FASTENERS: RED HEAD ITW TAPCON (SEE INDIVIDUAL DETAILS FOR MINIMUM EMBEDMENT DEPTH INTO CONCRETE) 3/8' DIA. FASTENERS: 3/8' TRU BOLT WEDGE ANCHOR (SEE INDIVIDUAL DETAILS FOR QUANTITY OF FASTENERS NEEDED) (MINIMUM EMBEDMENT SHALL BE 3' INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) DESIGN DISCLAIMER 3/8' LARGE DIAMETER TAPGON (LOT) (SEE INDIVIDUAL DETAILS FOR QUANTITY OF FASTENERS NEEDED) (MINIMUM EMBEDMENT SHALL BE 2112' INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) FOR BRICK PAVER INSTALLATION: FOR INSTALLATION ON A BRICK PAVER DECK, THE ONLY FASTENERS THAT WILL MEET THE DESIGN CRITERIA INDICATED WITHIN THESE DESIGN SPEC' S ARE THE RED HEAD TRU BOLT WEDGE ANCHOR (3/5' x I'), WHICH BASED ON 1/8' ANGLE, I x 2 D.B., 21ia' THICK BRICK PAVER AND A MAXIMUM MORTAR BED THICKNESS OF 3/4'. THIS SCENARIO WILL STILL MEET THE MINIMUM FASTENER EMBEDMENT. IF ANY OF THESE CONTRIBUTING FACTORS EXCEED THE DIMENSIONAL BREAKDOWN INDICATED, THE JOB MUST BE PRESENTED TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC ANCHORING DESIGN. EXIST. HOUSE FASCIA NOTES: IT SHALL BE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO INSPECT AND INSURE THE CONDITION --OF THE EXISTING FASCIA, TO DETERMINE IF IT IS IN GOOD- - -- ENOUGH CONDITION TO SUPPORT THE PROPOSED SCREEN ENCLOSURE (PRIOR TO ITS INSTALLATION) THERE IS NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IN THIS ENGINEERING DESIGN DOCUMENT REGARDING THE ABILITY OF ANY HOST STRUCTURE TO RESIST THE BUILDING CODE SPECIFIED DESIGN LOADS IMPOSED BY ANY PROPOSED SCREEN ENCLOSURE. SUCH CERTIFICATION WILL BE DEPENDENT ON AVAILABILITY OF ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS, AS WELL AS ORIGINAL PERMIT AND INSPECTION RECORDS FOR THE HOST STRUCTURE. CERTIFICATION OF THE HOST STRUCTURE, IF IT IS REQUIRED, WILL ULTIMATELY BE POSSIBLE ONLY IF THESE RECORDS CONTAIN ALL THE INFORMATION NEEDED BY THE ENGINEER TO PERFORM ALL OF THE NECESSARY ANALYSIS TO DETERMINE IF SUCH CERTIFICATION IS EVEN POSSIBLE. 1= u. o Lwu_ W 2 CD WiLu QoG O wo 0 c w Lu 0 0 L ®vpzp �CL w8 4E ® L ZWC)Q0 9L.! = � n ®�� e- 020�5 �� �03 LLI J=ice 0 I�- 0- ®!F:E co �d ¢ cccjj����SS c� a r, L ®14� dew cdz �u� GENERAL NOTE5 AND [DE51GN PARAMETERS: I. THE OVERALL DESIGN COMPLIES WITH THE 2006 AMENDMENT TO THE FLORIDA BUILDING CODE 2004 (CHAPTER 16 AND 20), AND 15 BASED ON THE FOLLOWING PARAMETERS: A. WIND SPEED: 140 M.P.N., 3-SECOND GUST B. EXPOSURE CATEGORY 'C' (NON-HVHZ ONLY) C. DESIGN FRE55UREB AS FOLLOWS: a) SIMULTANEOUS WIND LOADING g 8 P.SF. FOR SCREEN ROOF AND 2S PAP. FOR SCREEN WALLS b) 300 LB LOAD APPLIED VERTICALLY DOWNWARD ALONG ANY ONE FOOT (12-INCHES) OF ANY PRIMARY MEMBER (EXCLUDING DIAGONAL WIND BRACING, WHICH 15 TREATED AS A 'STRUCTURAL MEMBER' UNDER 2006 AMENDMENT DEFINITIONS. D. MAXIMUM ENCLOSURE HEIGHT SHALL NOT EXCEED 20-FEET E. ALLOWABLE DEFLECTION OF 'L / 60', AS SPECIFIED IN TABLE 01610.1, FOR NON -HIGH VELOCITY HURRICANE ZONES. F. CONTINUOUS LOAD PATH IS PROVIDED, 2. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD): A. ALL EXTRUSIONS SHALL BE ALUMINUM ALLOY %06346 (NOTE THAT THE SPLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALLOY 060(o1-T6, IF THIS MATERIAL IS MORE READILY AVAILABLE TO THE CONTRACTOR) (SEE COMPONENT 5HAPE5 AND SIZES AT RIGHT). B. FASTENERS SHALL BE ALUMINUM ALLOYS 2024-T4 i 101546, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL, OR 300-6ERIE5 STAINLESS STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE APPROPRIATE MEANS FOR SEPARATION OF DISSIMILAR MATERIALS AS THEY ARE DEFINED IN SECTION 02003.8.4. THE CONTRACTOR MAY IMPLEMENT ANY OF THE MEANS SPECIFIED IN THIS SECTION. ANY ALTERNATIVE MEANS MUST BE ACCOMPANIED BY A LETTER OF CERTIFICATION FROM THE PRODUCT'S MANUFACTURER (THIS LETTER MUST BE SIGNED AND SEALED BY A FLORIDA LICENSED STRUCTURAL ENGINEER), WHICH STATES THAT THEIR PRODUCT MEETS / EXCEEDS ALL OF THE REQUIREMENTS SPECIFIED IN THE ABOVE - LISTED SECTION. THIS LETTER SHALL ALSO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD FROM BD.Q,, INC. C. SCREEN CLOTH SHALL BE VINYL COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 x 14 (58% OPEN). 3. ALL FASTENERS THAT PASS THROUGH ANY EXTRUSION INTO CONCRETE, MASONRY, WOOD, STEEL, ALUMINUM OR ANOTHER EXTRU51ON SHALL HAVE A 5/8-INCH DIAMETER WASHER, MINIMUM (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD), AND SHALL BE NO MORE THAN 18-INCHE5 CENTER - TO - CENTER SPACING. 4. ALL FASTENERS ADJACENT TO UPRIGHTS THAT DO NOT REQUIRE REINFORCING ANGLE CLIPS, SHALL BE PLACED WITHIN TWO (2) INCHES OF THAT UPRIGHT (TYP. FOR BOTH SIDES). 5. SCREEN DOOR(S) MAY 13E LOCATED IN ANY SCREEN WALL PANEL, EXCEPT FOR THOSE THAT CONTAIN DIAGONAL WIND BRACING CK-BRACING'). ALL DOORS SHALL BE SELF -CLOSING AND 5ELF-LATCHING. DOORS INSTALLED IN AN ENCLOSURE THAT SURROUNDS A POOL / SPA SHALL HAVE DOOR LATCHES INSTALLED FIVE (5) FEET ABOVE THE FLOOR, MINIMUM. (a. COPIES OF THIS ENGINEERING SPECIFICATION / DESIGN DETAIL ARE TO ONLY BE CONSIDERED VALID FOR PERMITTING OR DESIGN CERTIFICATION PURPOSES WHEN ALL SHEETS OF ANY SUBMITTED SET BEARS THE ENGINEER'S ORIGINAL SIGNATURE (IN BLUE INK), UNDER HIS EMBOSSED SEAL. B.D.Q., INC. SHALL NOT BE RESPONSIBLE FOR NON -ORIGINAL COPIES THAT ARE SUBMITTED, THAT HAVE ANY UNAUTHORIZED CHANGES, ALTERATIONS OR DELETIONS ON THEM. 1. THESE ENGINEERING DETAIL DRAWINGS ARE ONLY VALID IF THE DATE ACCOMPANYING THE ENGINEER'S ORIGINAL SIGNATURE 15 LESS THAN 90 DAYS OLD. NO BUILDING OFFICIAL OR BUILDING DEPARTMENT SHOULD ACCEPT COPIES THAT ARE OLDER THAN THIS, AND SHOULD REQUEST THE SUBMITTING CONTRACTOR OBTAIN UPDATED / CURRENT ENGINEERING. a. ALL ENGINEERING SPECIFICATIONS AND DETAIL DRAWING CONTAINED WITHIN THIS ENGINEERING DOCUMENT ARE THE 60LE PROPERTY OF B.D.Q., INC. ANY UNAUTHORIZED COPYING OR OTHER REPRODUCTION IN PART OR WHOLE OF THESE DOCUMENTS WILL NOT BE PERMITTED AND WILL BE PROSECUTED TO THE FULLEST EXTENT ALLOWED BY LAW. S. THERE SHALL BE NO REDISTRIBUTION OF THESE ENGINEERING DOCUMENTS BY THE PERSON OR COMPANY THAT ORIGINALLY PURCHASED SIGNED AND SEALED COPIES FROM B.D.Q., INC., WITHOUT EXPRESS WRITTEN AUTHORIZATION FROM B.D.Q., INC., AND THE ENGINEER OF t ECORD. WALL COLUMN SCHEDULE (ALLOW. CO UMN HEIGHTS VS. WALL PANEL WIDTH) U60 MAX. ALLOWABLE DEFLECTION (14,0 MPH, EXP. " ", 29 P.S.F. DESIGN LOAD) DIMENSION COLUMN HEIGHT VS ALL PANEL N TH (DESIGN PRESSURE = 21 PSF) SIZE Tf Tw 8' 0' 7' 6" 7' 0" 6' 6• 6' 0' S' 6" 604 4' 6" 4' 0' 2x4 L .100 .045 6' 4' 6' 1' 6' 9' 1' 0' 1' 4' 1' 8' 8' 0' 8.6. 1310. 2x5 L .116 .060 1' 8' 8' 0' 8' 3' 6' 1' V II' 1313, 13,15, 1013, 10.11. 2x6 L .120 .050 1 8' 0' -8' 3' 8' 6' 8' 9' V 2' 9' 6' 10' 1' 10' 1' II' 3' 2x7 L .120 .057 8' 8' v 0' 9' 3' v 8' loll, I& 6' II' 0' II' 1' 12' 3' WI L .224 .072 10' 1' II' 0' II' 4' II' 8' 12' 3' 12' 9' 13' 5' 14' 2' 15' 0' 2x9 L (L) .209 .072 12' 10' 13' 3' 13' 8' 14' 3' 14'S' 15' 5' 16' 2' 11' 1' 18' 2' 2x9 L (H) .306 .082 15' 9' 16' 4' IT O' 11' 1' 18' 3' 19' 2' 20' 1' 21' 1' 22' 4' 2x10 L 1 .389 .092 18' 'Y 19' 4' 20' 1' 20''B' 21' 8' 22' 1' 23' 8' 24' II' 26' A. /'7 TF COMPONENT 5HAPE5 AND 5PEG f F f GAT f ON5 093 Tw r 5 •044 .040 � .010 � .010 O L 2' 2' I 31 Ix30.5. Ix20.13. 2 2 x 2 x .0133 TUBE Z x 3 °N" 3 x 3 'N' DIAG. BRACING �"� THE ACTUAL VALUES FOR 'Tf' (FLANGE THICKNESS) AND 'Tw' (WEB THICKNESS) FOR THE VARIOUS SELF -MATING CV) SIZE SELF -MATING MATERIAL ARE INDICATED ON THE UPRIGHT HEIGHT AND BEAM SPAN TABLES. z w z i E w N a w z FRI I I^er G-rV`rI I,nn 1111ri I H05T STRUCTURE WITH STRUCTURAL GUTTER MANSARD ROOF BEAM SPAN MANSARD BEAM 5PAN5 ARE BASED ON A MAXIMUM SPLICE ANGLE OF 30- FOR HALF -MANSARD SEAM SPANS, USE VALUES SHOWN IN 'MANSARD BEAM SPAN TABLE (SAME MAX. SPLICE ANGLE (30') APPLIES TO HALF -MANSARD BEAMS) HOST STRUCTURE WIT STRUCTURAL GUTTER PEAK / GAI3LE ROOF BEAM SPAN i w BEAM SPANS AND COLUMN SIZES ON THIS SHEET ARE BASED ON SIMULTANEOUS LOADING, AS DEFINED IN TABLE 02002.4, F.B.C. 2004, FOR 140 MPH WINDS, FOR EXF06URE CATEGORY 'C' (29 P.S.F. WALLS, 8 P.5F. ROOF, FOR NON-HVHZ) FLAT SIMPLE ROOF BEAM SCHEDULE RRRAT Mo. U'80wx 040MPH, EXPOS. B') DIMENSION I ROOF PANEL WIDTH vs BEAM SPAN (FOR MAX. WALL HEIGHT OF IV 01 SIZE Tf Tw 8' 0" T 6' T 0' V 6' V 0' Sir S 0" 4' 6" 4' 0" 2x4 L .100 .045 12' 0' 12' 5' 12' 10' 13' 3' 13' 11' 14' 6' 15121 16' 0' 11101 W L .116 .050 14' 1' 15' 1' 15' 1' IV 2' IV 9' 11' 1' 18' 5' 19' 4' 20' 5' 29 L A20 .050 15' 2' 15' T 1V 2' 16' 9' 1T V 18' 2' 19' 1' 20' 1' 21' 3' W L .120 .057 16' 6' 11' 0' Il' 1' 18' 3' 19' 0' 19' 9' 20' 8' 21' 9' 23' 0' 2x8 L .424 ,072 20' 0' 20' 8' 21' 4' 22' 2' 23' 0' 24' 0' 25' 1' 2(.'4' 21' 11' 24 L (L) = .072 24' 2' 25' 0' 25' 9' 26' 9' 21`3' 29' m' 30' 3' 31' 10' 33' 8' 24 L .3N .082 29' 9' 30' 9' 31' 10' 32' 11' 34' 3' 35' 1' 31' 3' 39' 2' 41' 4' 2x10 L .389 .092 35' 0' 36' 2' 31' 4' 38' 8' 40' 2' 41' 9' 43' 8' 45' 9' 48' 3' 0) REPRESENTS SPAN VALUES THAT ARE DEFLECTION -LIMITED BEAM SPAN CALCULATION NOTE: THE SPANS IN THESE TABLES ARE BASED ON BOTH THE HOST STRUCTURE MOUNTING POINT AND WALL HEIGHT BEING THE SAME MEASUREMENT MANSARD / CENTER PEAK (GABLE) ROOF BEAM SCHEDULE use nux (14o MPH, UP. %I *THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL RISE OF 3' 0' (36')* DIMENSION ROOF PANEL WIDTH vs BEAM SPAN (FOR MAX. WALL HEIGHT OF V 01 SUE Tf Tw I 8' V T 6' T 0' V 6" 6' W S 6' S 0' . 4' 6' 4' 0' 2x5 L .116 .050 2x6 L A20 .050 10101 2x7 L .120 .067 8' 9' 1112, 1315, 24 L .224 .072 8' 9' 10' 4' 12' 0' 13' 6' 15' 2' 16' 10' 18' 10' 20' 11' 2x9 L (L) .209 .072 1V 1' 16' 3' Il' 6' 19' 0' 20' 5' 22' 0' 23' 9' 25' 9' 28' 0' 2x9 L (H) .3N .082 23' 0' 24' 3' 25' 1' 21' 0' 28' 6' 30' 3' 32' 3' 34' 6' 36' 11' 2x10 L • 2 29' 6' 30' 11' 1 32' 3' 1 33' 9' 35' 6' 1 31' 5' 1 3V 6' 41' II' 1 44' 8' MANSARD / CENTER PEAK (GABLE) ROOF BEAM SCHEDULE Lw mAx (too PH, w. Tj 'THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTI AL RI E OF V00 (36")* DIMENSION ROOF PANEL WIDTH vs BEAM SPAN (F R WALL H IGHT OF 12" 0) Sim Tf Tw 8' 0" 7' 6" T 0' V 6' V 0" 5'Vv S 0" 460 N 0" 2x5 L .116 .050 2x6 L .120 .050 2x7 L .120 .057 2x8 L .224 .072 10' 1' 1 6' 16' 5' 2x9 L L 2W .072 9' 4' II' 5' 13' 5' 15' 6' 1' 19' 9' 2' 2' 24' 8' M L H .308 .082 18' 9' 20' 3' 21' 8' 23' 6' 25' 4' 2l' 3' 19' 5' 31' 9' 34' 6' 2x10 L 1 •30 L092 265' 1 21' 10' 29' 5' 1 31' 2' 1 33' I' 35' I' 31' 3' 3V V 42' S' MANSARD / CENTER PEAK GABLE ROOF BEAM SCHEDULE use mAx. (too MPH, Ev.'c7 *THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL RISE OF 3' 0" (36')* DIMENSION ROOF PANEL WIDTH vs BEAM SPAN (FOR MAX. WALL HEIGHT OF 16 CO SIZE Tf Tw 1 8'0" TW 70' 6'6" 6'0' SW S0" 4'6' 4! 0" 2x7 L .120 .057 -0- -1 2x6 L .224 .072 10' 2x9 L (L) .209 .072 pn)'B'B' 8' 0' II' 6' 14' 9' 11' 9' 21' 0' 2x9 L H .308 .082 13' 3' 15' 3' 11' 4' 21'6' 23'9' 26'4' 29'0' 32'0' 2x10 L .389 •092 22'9' 24'6' 26'4' 283 30' 2' 32' 5' 34' II' 31' 6' 40' 8' MANSARD BEAM SPANS OF LE55 THAN 8' 0' ARE OMITTED FROM THIS TABLE �602w CL�!� a 4R 9v8�i�c� ac W_raz Oie0O� o 41 uj ';jE Ili g(0 a 00 W w w z0a muuj w0<p �• W o23�a w 5 1OW= 810 L§ UP TO 16' BEAM SPAN 16' TO 24' BEAM SPAN 24' TO 32' REAM SPAN 32' TO 40' BEAM SPAN O-INDICATES WALL PANEL THAT SHALL HAVE DIAGONAL "K"-BRACING IN IT UP TO 8' WALL HGHT EXIST. HOST STRUCTURE EXIST. HOST STRUCTURE NUMBER OF PANELS VARIES 8' TO 12' WALL HGHT EXIST. HOST STRUCTURE TOTAL NO. OF BAYS VARIES THREE (3) BAYS ON EACH END OF OUTER -MOST WALL SHALL HAVE DIAG. BRACING EXIST. HOST STRUCTURE TOTAL NO. OF BAYS VARIES 'THREE (3) BAYS ON EACH END OF OUTERMOST PANELS AND TWO (2) PANELS IN SECOND OUTERMOST ROW OF PANELS SHALL HAVE THE DIAGONAL BRACING (AS SHOWN) THE BRACING SCHEMATICS SHOWN ABOVE ARE THE SAME BRACING CONFIGURATION, REGARDLESS OF ROOF TYPE (MANSARD, PEAK, DOME, FLAT, ETC.) DESIGN NOTES: ALL DIAGONAL BRACING, USED EITHER IN THE ROOF OR AS 'K'-BRACING IN THE WALLS SHALL BE 2' x 2' x .093 WALL THICKNESS TUBE, AND SHALL BE CUT TO FIT SNUG, WITH NO PLAY OR SHIFT IN THE BRACING. SEE DETAILS AT RIGHT FOR CONNECTION SPECIFICATIONS DESIGN NOTE: ALL THRU-BOLTS PASSING THROUGH ANY ALUMINUM MATL. WITH A WALL THICKNESS LESS THAN .090, SHALL HAVE A Ilia -INCH (OUTSIDE DIA.) FENDER WASHER (SEE GENERAL NOTE'12 ON SHEET k2 REGARDING SEPARATION OF D1561MILAR METALS). THE CONTRACTORS MAY, IF THEY CHOOSE, INSTALL THE ANGLE CLIPS FOR THE DIAGONAL TUBE BRACING (WHERE IT ATTACHES TO THE SELF - MATING SCREEN ROOF BEAMS) WITH THE THRU-BOLTS ONLY PASSING THROUGH ONE HALF OF THE BEAM. THIS IS A STRUCTURALLY ADEQUATE ALTERNATIVE, AND WILL PERMIT INSTALLATION OF THESE ANGLE CLIPS IN THEIR SHOP, DURING FABRICATION (POSSIBLY SAVING TIME DURING INSTALLATION IN THE FIELD). NOTE: ALL DIAGONAL BRACING SHALL BE ATTACHED VIA THE 2 x 2 x I/a" ANGLE CLIPS, AS SHOWN, AND SHALL HAVE EACH END ATTACHED TO EITHER THE SCREEN ROOF BEAM OR TO THE EVE RAIL.. NO DIAGONAL BRACING SHALL BE ATTACHED TO ANY OF THE ROOF PURLINS 2 x 3 x .010 SCREEN ROOF PURLIN 2 x SMB SCREEN ROOF BEAM (TYP) b SPLICE JOINT 2 x 2 x pia' ANGLE CLIP, CUT AT A 45' (+/-) ANGLE AND ATTACHED TO THE SCREEN — — ROOF BEAM WITH ONE (1) lid' DIA. THRU-BOLT, WITH FENDER WASHER (SEE DESIGN NOTE ABOVE UPPER ANGLE CLIP TO BE PLACED AT SAME ANGLE AS THE MANSARD LEG OF THE SCREEN ROOF BEAM 2 x 3 x.010 EVE RAIL 2 x 2 x 's' ANGLE CLIP, CUT AT A 45' (+/-) ANGLE AND ATTACHED TO THE 2 x 3 x .010 EVE RAIL WITH ONE lU 1114' DIA. THRU-BOLT, WITH FENDER WASHFR(SEE DESIGN NOTE ABOVE 2 x 3 x .010 SCREEN ROOF PURLIN Sal 2 x 2 x .093 DIAGONAL ROOF BRACE, -CUT ----- AT 45' ANGLE (+/-) AT EACH END AND ATTACHED TO EACH ANGLE CLIP WITH A I/4' DIA. THRU-BOLT, AS SHOWN TYPICAL ANGLE ARTICULATION TO CREATE UPWARD ANGLE DI ATONAL ROOF 5RAGING DETAIL Ur F., 1= w o00 z � w o � >��a o9®� w=o Z g O zcn�a"� oWw00z F5EAM 5PLIGE 5PECIFIGATION5 8' [a (a w w p = _ •14 TEK SCREW �. w (TYPICAL) SV 9 0 0 o e v o 0 1 0 0 0 0 O ON 10 0 0 1 1 0 0 0 0 11 0 0 ® 0 0 0 0 0 10 o 1 0 S 10 d LLI iN w �10 � SPLICE PLATE MATERIAL. SHALL BE 1/4' THICK (MIN.) AND IBE EITHER 06063-T6 OR "6061-T6 ALLOY BEAM SPLICE DETAIL (2 x 8 SEAMS AND LARGER) *(MU5T USE 1/4" THICK GU55ET PLATE) 014 TEK SCREW (TYPICAL) _ 0 - -- 0 1 0 0 .. 0 0� 1 0 0 1 110 0 0 0 0-1- 1 0 1 0 \Z' 10S A�- PLATE �1U7'�N SPLICE PLATE MATERIAL. SHALL BE 3/16" THICK (MIN.) AND BE EITHER 06063-T6 OR "6061-T6 ALLOY SEAM SPLICE DETAIL (2 x I E3EAM5 AND SMALLER) �. s(MU5T USE 3/16" THICK GUSSET PLATE)* TYPICAL OR 1/4' TF SPLICE P SPLICE PLATE TOLERANCE NOTE - ALL SPLICE PLATES (ALUMINUM ALLOY %063-T6 or %O&I-T6) SHALL BE CUT TO BE +0.000 / -02625, AS INDICATED IN THE SCHEMATIC DRAWING AT LEFT SAME AS 'A' BEL( JUST REVERSED 3x3x.010H CORNER UPRIGHT is 4-INCH x 4-INCH x .010 PLATE, WITH (4) *12 TEKS IN THE 3 x 3, (3) 012 TEKS IN THE BOTTOM I x 2 AND (3) 012 TEK IN THE 2 x 2 BRACI COLUMN 1 2x2x.0133T DIAGONAL. BF I x 2 BOTTOM SCREEN-FRAr DIAr-30NAI_ UUALL 5RACING CK' 5RAGING> DETAIL 7--2x3x.010ROOF PURLIN - �—Ix20BTOP SCREEN FRAME 2 x 2 x .CS3 TUBE DIAGONAL BRACE 3 x 3 x.010 CHAIR RAIL 2x2xOWTUBE - DIAGONAL BRACE DETAIL "A" (OUTSIDE) (INSIDE) I x 2 OB BOTTOM SCREEN FRAME 3 I. CORNER 1LUMN 2 x 2 x .093 TUBE DIAGONAL BRACE I x 2 BOTTOM 5CREENFRAME (-INCH x 3-INCH x .093 ANGLE, CUT 4- INCHES LONG, WITH (3) 112 TEKS IN THE 3 x 3,(3) 112 TEKS IN THE BOTTOM I x 2 AND (3) M2 TEKS IN THE 2 x 2 BRACE 2 x SMB SCREEN ROOF BEAM 2 x SMB UPRIGHT 2 x 2 x .093 TUBE - DIAGONAL BRACE 3x3x.010—� CHAIR RAIL 2 x 2 x .OS3 TUBE - DIAGONAL: BRACE 2 x 5 SMB UPRIGHT (MINIMUM SIZE) 2 x 2 x .093 TUBE - DIAGONAL BRACE 2 x 5 SMB UPRIGHT (MINIMUM SIZE) 3x3x.010 CHAIR RAIL DETAIL '13 0 0 0 0 ° 0 0 0 00 0 0 0 0 0 0 (OUT5IDE) N. H O W. o mo0� 9waa 0ID 0 U-a9R€ �0� w Lu v>I.- a. >- LL O au.), VI 0) to �z Im WW w pp `,iug 4-INCH x 10-INCH 51 x .010 PLATE, WITH (1) p W 012 TEKS IN THE SMB UPRIGHT, (3) 012 TEKS O IN THE CHAIR RAIL AND (3) #12 TEKS IN EACH 2 x 2 BRACE 3x3x210 CHAIR RAIL I -INCH x 3-INCH x .093 ANGLE, CUT 4- INCHES LONG, WITH (3) #12 TEKS IN THE SMB UPRIGHT AND (3) 112 TEKS IN THE 2 x 2 BRACE — 3 x 3 x .010 CHAIR RAIL I -INCH x 3-INCH x .093 ANGLE, CUT 4- INCHES LONG, WITH (3) P12 TEKS IN THE SMB UPRIGHT AND 2 x 2 x .093 TUBE 1 (3) 12 TEKS IN THE DIAGONAL BRACE 2 x 2 BRACE (fN51DE. 0 0 0 Ki t!i LiL 9i zLLJ ce 8 ® LJJ z W l U W �c� ®i�-�� 0 cno rz-' . T r w a tj ui"�';z 6.0 a.m � iE 4 0 cy z� O L4 0 z m o -.-, ��r a I 6CREEN ROOF ENCL05URE-T0-H05T LTRUCTURE ATTAGH NT [DETAIL DE51GN NOTE: THE 3-INCH LEG OF THE ANGLE SHALL BE PLACED AGAINST THE I x 2. THIS ALLOWS A MIN. EDGE DISTANCE FOR THE FASTENERS (FROM THE EDGE OF THE ANGLE) OF ONE -INCH, AND MAINTAINS A SIX-INCH MIN. CENTER -TO -CENTER D15TANCE FOR THE MAX. SIZED CONCRETE ANCHORS (3/8' x 31%') CAP (TYP) HOST C.B.S. WALL (TYP) TYP SCRI=I=N ROOF BEAM I x 2 2' x 3' x .125' ANGLE W/ (4) 012 TEK5, TYP. EACH SIDE OF BEAM FASCIA REINFORCEMENT [DE516;rN NOTE: ALL FASCIA BOARDS ON ANY EXISTING HOST STRUCTURE THAT WILL HAVE ANY PART OF THE PROPOSED SCREEN ENCLOSURE ATTACHED TO IT SHALL BE REINFORCED, BY PLACING ONE lU 1/4' x 4' LAG SCREW INTO THE END OF EVERY TRUSS TAIL (WHERE THE PROPOSED 5CREEN ENCLOSURE IS BEING INSTALLED). THESE TRUSS TAILS MUST BE PILOT DRILLED WITH A 5/32" DRILL BIT TO PREVENT SPLITTING THE END OF THE TRUSS TAILS. IT SHALL BE THE REP5ON515ILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THIS STEP 15 COMPLETED, AS SPECIFIED, PRIOR TO ANY INSTALLATION TAKING PLACE. FASTENER SHALL BE 1/4' x 3 1/2' RED -HEAD ITW TAPCON FOR ALL 2' x 6' BEAMS AND SMALLER. FASTENERS SHALL BE 3/8' DIA. FOR 2' x 7 BEAMS AND LARGER (SEE DESIGN NOTE ABOVE REGARDING: 3/8 FASTENER SPACING) WALL ATTACHMENT FASCIA REINFORCEMENT 5PECIFICATION5 1/4' x 4' LAG SCREW, TO BF INSTALLED INTO THE END OF EVERY T%55 TAIL WHERE A 5CREEN ENCLOSURE WILL BE ATTACHED. THE TRUSS TAIL SHALL BE PILOT - DRILLED WITH A 5/32' DRILL BIT (TO PREVEN' SPLITTING THE END OF THE TRUSS TAIL) 10-INCH LONG 025 THICK) EXTRUDED 'Z' GUTTER INSERT, TYP CENTERED ON SEE 'SNAP / LAP CONNECTION' EACH ROOF BEAM, WITH FOUR (4) 110 NOTE ON SHEET I FOR SPEC.'S TEK5 THRU TO_ P LIP OF GUTTER 2 x 3 x .125 ANGLE CLIP (CUT 2' LONG) W/ 3-INCH 1/4' x 21/4' LAGS, FOUR (4) LEG AGAINST 1 x 2. CLIP IN EACH 10-INCH INSERT SHALL HAVE FOUR (4) "12 AND AT 24' O.C. (MAX. �" TEK5 INTO SIDE OF ROOF SPACING) IN THE REST o BEAM AND TWO (2) #14 x OF THE GUTTER (PILOT -" e 2' TEK5 (PER ANGLE CLIP) DRILL FASCIA W/ 5/32" � THRU GUTTER AND INTO 7' BIT TO AVOID SPLITTING) GUTTER INSERT (TYP. ONE n ANGLE CLIP ON EACH 51DE ® OF EACH BEAM) `-TYP. 2 x SCREEN ROOF zI _ BEAM (MAY BE FLAT 5' STRUCTURAL 7 I x 2 SCREEN OR SLOPED) GUTTER (CONT.) FRAME (TYP) PLAN VIEW TRU55 TAIL (TYP) CAP (TYP) 2 x FASCIA BOARD (TYP) NOTE: FASCIA ATTACHMENT REQUIRES A 2 x FASCIA BOARD (MINIMUM). A 'I x' FASCIA 15 ONLY ADEQUATE FOR THIS INSTALLATION WHEN THERE IS A 2 x SUB - FASCIA BEHIND IT. IN THIS CASE, THE LAGS MUST PENETRATE THE 5UB-FASCIA I1/2' (MIN. EMBEDMENT). IT SHALL BE THE RESPONSIBILITY OF THE SCREEN CONTRACTOR TO VERIFY THE PRESENCE OF THIS SUB -FASCIA. 10-INCH LONG (.125 THICK) EXTRUDED - 'Z' GUTTER INSERT, TYP CENTERED ON EACH ROOF BEAM, WITH FOUR (4) 010 T%S THRU TOP LIP OF GUTTER 2 x HOUSE FASCIA (SEE FASCIA NOTE ABOVE) 114' x 21/4' LAGS, FOUR (4) --�-�� IN EACH 10-INCH INSERT AND 24" O.C. (MAX. / SPACING) IN THE REST OF THE GUTTER (PILOT DRILL FASCIA W/ 5/32' F31T TO AVOID SPLITTING) I x 2 x .093 ANGLE SPACER - (FOR ANGLED FASCIA BD. ,ATTACHMENT), ATTACHED L'J/ TWO (2) ROWS OF 010 TEKS '(3TAGGERED), EACH ROW AT W O.G. (MAX. SPACING) STRUCTURAL GUTTER CONNECTION [DETAIL TYP SCREEN ROOF BEAM I x 2 2' x 2' x .125' ANGLE W/ (4) "12 TEK5, TYP. EACH SIDE OF BEAM 1/4' x 2 1/2' LAG SCREW TYP. I EACH 51DE OF BEAM (2' x (o' BEAMS AND SMALLER) 3/8' x 2 1/2' LAG SCREW (2' x l' BEAMS AND LARGER) FASCIA ATTACHMENT SEE "SNAP / LAP CONNECTION' NOTE: ON SHEET I FOR SPEC.'S TYP. 2 x SCREEN ROOF BEAM (MAY BE FLAT OR SLOPED) 0 0 2 x 3 x .125 ANGLE CLIP 0 o (CUT 2' LONG) W/ 3-INCH LEG AGAINST I x 2. CLIP o SHALL HAVE FOUR (4) 012 o TEK5 INTO 51DE OF ROOF BEAM AND TWO (2) "14 x U-CHANNEL 2' TEK5 (PER ANGLE CLIP) CAP (TYP) . THRU GUTTER AND INTO 'Z' I x 2 SCREEN GW'TER INSERT (TYP. ONE FRAME (TYP) GLE CLIP ON EACH SIDE �— 5' STRUCTURAL OF EACH BEAM) _ GUTTER (GONT.) --71 SECTION VIEW ` 14 yU o so Ci8 LJ.1ZZ: ® CH w i o P a-Cn C 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) SIDE WALL w I x 2 OB BOTTOM FRAMEtu z I x 3 OB 51DE-WALL CORNER to UPRIGHT PLAN VIEW 2 x 3 x .010 EVE RAIL, TYP. (CONTINUOUS) I x 2 OB TOP FRAME I x 3 OP SIDE -WALL CORNER UPRIGHT 010 x 2' SM5 SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE 03, SHEET 02) TO BE 18- INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 2 x 3/16' ANGLE, WITH FOUR (4) #12 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) I x 2 OB BOTTOM FRAME ELEVATION VIEW FRONT WALL I x 2 OB BOTTOM FRAME 2 3/4% MIN. EDGE D15TANCE 3 x 3 x .010 FRONT WALL CORNER UPRIGHT 010 x 2' SMS SCREW, WITH 5/6' DIA. WASHER (SEE GENERAL NOTE 03, SHEET IV TO BE 0- INCHES, CENTER -TO -CENTER MAX. SPACING MANSARD SCREEN ROOF BEAM (BEYOND) 2 x 5 x %' ANGLE (2-INCHES LONG) WITH (2) 014 TEKS INTO TOP OF 2 x 3 EVE RAIL AND (2) 014 TEKS INTO THE FRONT OF THE 3 x 3 H FRONT WALL CORNER UPRIGHT 3 is 3 x .010 FRONT WALL CORNER UPRIGHT 2 3/4', MI / EDGE D15T NCE 0 0 CORNER UPRIGHT DETAIL NOTE: THIS ATTACHMENT I x 2 O.B. SCREEN FRAME, DETAIL ALSO APPLIES TO TYP, BETWEEN UPRIGHTS A 2 x 2 SCREEN FRAME, OR AS UPRIGHTS AGAINST W/ THE FASTENER 6EING A WALL OR COLUMN 4' IN LENGTH, TO I/4' DIA. x 3l/4' TAPCON MAINTAIN A 2' MIN. TO BE PLACED AT -NO MORE EMBED, THAN 18' D.G. (RE: GEN. NOTE S) MIN. EMBEDMENT FOR CONC. / C.B.S. / MASONRY ALL TAKONS SHALL SURFACE . BE 2' INTO CONCRETE. NOTE: ALL FASTENERS SPECIFIED IN 'COLUM-TO-FOUNDATION' DETAILS PERTAIN ONLY TO THE FASTENERS TO BE PLACED ON EITHER SIDE OF COLUMNS. THIS DETAIL 15 FOR ALL INTERMEDIATE FASTENERS FOR I x 2 SCREEN FRAME TO EITHER CONG. DECK OR C.B.S. MASONRY WALL. 2 x 3 x .010 ROOF PURLIN 2 x 3 x .010 EVE RAIL, TYP. (CONTINUOUS) 2 x 5 x '/8' ANGLE (2-INCHES LONG) WITH (2) 114 TEKS INTO TOP OF 2 x 3 EVE RAIL AND (2) 114 TEKS INTO THE FRONT OF THE 2 x SMB SIDE WALL UPRIGHT I x 2 OB TOP FRAME 110 x 2' SMS SCREW, WITH 5/0' DIA. WASHER (SEE GENERAL NOTE 03, SHEET *2) TO BE 18- INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 5 SM5 UPRIGHT (MINIMUM 51ZE FOR ANY UPRIGHT ON A SCREEN ROOF ENCLOSURE) 23/4' MIN. EDGE DISTANCE SEE 'MINIMUM FOOTER TABLES' ON SHEET 01 0 0 0 21/8' x I1/2' U-CHANNEL. CLIP ATTACHED TO THE EVE RAIL WITH SIX (6) 012 TEKS, AND (3) 012 TEKS INTO EACH SIDE OF THE 2 x 3 ROOF PURLIN (TO BE ATTACHED ON THE TOP END TO THE SCREEN ROOF BEAM IN THE SAME MANNER 2 x 4 x 1/8' ANGLE (2-INCHES LONG) WITH (2) *14 TEKS INTO E30TTOM OF THE 2 x 3 PURLIN AND (2) "14 TEKS INTO THE BACK OF THE 2 x SM5 61DE WALL UPRIGHT 3 x 3 x .010 CHAIR RAIL (TYP) 2 x 2 x 3/16' ANGLE, WITH FOUR (4) #12 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH. EMBEDMENT INTO THE CONCRETE) — I x 2 OB BOTTOM RAME __ ' SIDE WALL UPRIGHT PETAIL BEAM 61ZE 2x5-2x6 2x-1-2xa 2x9 2x10 2 x SMB SCREEN ROOF BEAM 2 x 3 x .010 ROOF PURLIN 2 x 5 x 1/9' ANGLE (2-INCHES LONG) WITH (2) 014 TEKS INTO TOP OF 2 x SM5 BEAM AND (2) #14 TEKS INTO THE FRONT OF THE 2 x SMB FRONT WALL UPRIGHT I x 2 OB TOP FRAME 010 x 2' SMS SCREW, WITH 5/6' DIA. WASHER (SEE GENERAL NOTE 13, SHEET w2) TO BE 18- INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 5 5MB UPRIGHT (MINIMUM SIZE FOR ANY UPRIGHT ON A SCREEN ROOF ENCLOSURE) 23/4' MIN, EDGE DISTANCE I x 2 OB BOTTOM FRAME — SEE 'MINIMUM FOOTER TABLES' ON SHEET 01 NO. OF #14 TEKS (PER SIDE) (2) #14 TEKS (4) *14 TEK6 (5) 014 TEKS (6) #14 TEKS 33/4' 3' MIN. MIN. z F SCREEN ROOF BEAM SHALL OVERLAP ON THE OUTER SIDE OF BOTH SIDES OT THE UPRIGHT (TYP. EACH BEAM -TO -UPRIGHT CONNECTION) SEE TABLE ABOVE FOR NUMBER OF *14 TEKS, AS SPECIFIED BASED ON BEAM 51ZE 3 x 3 x .010 CHAIR RAIL (TYP) 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 12 TEKS INTO THE UPRIGHT AND ONE (1)3/8' REP -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) FRONT WALL UPRI H 1�� _(lI= � t- 000 0 = C9 m LL 0 0 LLI U. El LL cc W 30 ozwco� �.. W Min p uj in 8 z a W8 IWO LL U ®z �ZZLL Lu ■ UJ e Lu UJI � 0 = C/3 �.` ? c: