Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSv SCANNED BY St. Lucoo Gggrq Permit Number: U 3 1 St. Lucie County Building & Zoning Department 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-1553 APPLICATION FOR STORM SHUTTER PERMIT WMW1MWMW"'- im 151MW!-n41 SEE REVERSE SIDE FOR INSTRUCTIONS DATE: 1. LOCATION/SITE ADDRESS: ?-COS N W O.o Yk t f" L' f 2. PARCEL ID NUMBER: �'�� 2.S " l00 S7 Ova tg • 000 — 3 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: (P AC'C.��n•�N 'r ✓d<< "Jt� 4. TYPE OF STRUCTURE: SFR--�- Addition OTHER 5. OWNERS INFORMATION Name: / OAS' fit. w —bAtji 5 i Address:.4� i r&...j c a - City: �p+ fScare: FL Q Phone: p / 9 Zip: C) 6. CONTRACTORS INFORMATION FL REG/CERT #: C) S6 O 1 —7 COUNTY CERT #: Business Name: Type of Surface attachment: Wood Frame Concrete �c Masonry —y— Other Product Type Minimum Design Pressure Product Compliance Report # Method of Attachment As per 1707.4.4.1 FBC 120 mph 130 mph 140 mph 140 Exp. C SBCCI Dade Other Anchor Type Anchor Spacing Impact Glazing Removable Panels Accordion FL3 s 9 -R 5' [-A w AD Roll Up lot • 1 OU. �S • • " Colonials Other ALL PRODUCTS SHALL BE LABLED SBCCI OR DADE COUNTY FOR DETERMINING IMPACT KE,L1TANUE FROM WIND BORNE DEBRIS. **SEE FINAL INSPECTION PROCEDURE FOR EXISTING RESIDENTIAL STRUCTURES ON BACK Ng �o 7. VALUE OF CONSTRUCTION: $ 10 i OWNER'S AFFIDAVIT: I certify that all of the information contained in compliance with all applicable laws regulating --Sbtw L.. 6 .6,ri e +J FEES DUE: RECEIPT: is correct and that all work will be done in � 1 SIGNATURE OF QUALIFIER/OWNER t,4' 1--«C 1 it. ACKNOWLEDGED BEFORE ME THIS 2:&— DAY OF kLL3LKhLOWN TO ME OR WHO Hg PRODUCED AS IDENTIFICATION. "tj C4-k IL s."o, I w9 TYPE OR PRINT NAME OF NOTARY COMMISSION NUMBER TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING WVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF 4T. INSTRUCTIONS Please complete all information in the space provided. All information must be Printed (use black or blue ink only) or Typed. This application for Shutters to be used for only those activities that is not otherwise included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition to the installation of Shutters, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. LOCATION/SITE ADDRESS: ............................................. 2. PARCEL ID NUMBER: ........................................................ Indicate the street address, or general location, of the property on which the building activity is taking place. Indicate the Property Tax Identification Number for the property on which the building activity is taking place. 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY........ Briefly describe the building activity under permit application. 4. OWNERS INFORMATION: ................................................. Indicate the name and address of the owner of the property on which the product is to be installed. 5. CONTRACTORS INFORMATION: .................................... 6. VALUE OF CONSTRUCTION: ........................................... Indicate the State of Florida (if applicable) and St. Lucie County contractor's registration numbers, and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. The value of construction is used to determine the amount of permitting fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. All applications for the installation of Shutters are to be submitted to the St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Following the issuance of this Shutter Permit, the scheduling of all required inspections may be made by calling (772) 462-1261. INSPECTIONS ** EXISTING RESIDENCES All shutters must be installed and in place at the time of the final inspection, except for Egress Windows and Doors where one panel must be installed and the remainder must be by the opening for the inspector to verify remaining panels. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 hftp://stiucleco.gov/ce BUILDING PERMIT Page 1 Issued: 03/28/2008 Conf A 810 Permit #: SLC- 0803-0312 Job Location: 2008 ROYAL FERN CT City: PALM CITY Permit Type: Storm Shutter Job Description: INSTALLATION OF 6 ACCORDION & 1 ROLL UP SHUTTERS FOR SINGLE FAMILY RESIDENCE Subdiv: Harbour Ridge#6 Track A Lot: 4 Block: Parcel: 4425-605-0018-000/3 Setbacks Left: Right: Number of Units: 1.00 Floors: 1 Minimum Floor Elevation: Front: Rear: Buildings: 1 Flood Map: 41 OF Flood Zone Zoning: PUD Square Footage: 0.00 X Elev: Job Value: $ 10,148.00 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3186824 OR BC;'— '"!955 PAGE 242, Recorded 03/28/2008 .r`� 2:38 PM AFTERNO — Raul. Gulfstream Aluminurn & Shutter Corp. 3001 SE Gran Park Way Stuart, FL 34997 P - MITNt IA, MB 772-287.6470 NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real prop, Florida Statues the following information is provided in the Notice of Commencem nt end in accordance with Chapter 713, 1. DESCRIPTION OF PROPERTY (Legal description and street address, if available) TAX FOLIO NUMBER: yy,Zf &65-- 0018 SUBDIVISION&b--4 1— n�BLOCK / TRpCf L01, BLDG i�O ( VIt41 J UNIT E Uri4 q Z1)pg NW ^( �lwC� 2. GENERALDFSCRIPTIONOFIMPROVEMENT; 3. OWNER INFORMATION: a. r v C. Interest in property d. Name and address of fee simple tideholder (if other than Owner) 4. CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER: 44, E3Y947 (172 Z87- 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State ofFlorida designated by Owner upon whom notices or Other documents may be served as provided by Section 713.13 (1) (a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: NIA 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1) (b), Florida Stahttes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date ofnotice of commencement (the expiration date is 1 year from the date of recording unless a different date is specified): _ 20_ XSignature of er or Print Neme and Provide Signatory's Title/Oftice r6 Owoer's of orized fficei/Dlrector/Partnermanager D State ofFlorida �� ,: County ofb}(,"4c The foregoing instrument was acknowledged before me this 2441l day of fit YGh� 20 Q q By. Mtn (nameofpeerson) For �'�,tt'j;� S1 (type of authority .... e.g. officer, trustee, attorney in fact) -.C-,:.r.�:+",�`.-� (name of party on behalf of whom instrument was executed) COD Personally known or_ produced the following type of identification:tIA���-��9/ aJD::'%ig()jdl': vi,�TrIRICNGJ -)N O VD 334790 x: ' '.:P:RES. Nohcrosr3, 2008 , 1 % (Signature . "T? r ��.`.•` Lc••dw tt✓u Nxnry iatfcUnEetwritas of Notary Public � CL CD Under Penalties of er u I declare that l have read the foregoing P belief (Section 92.525, Florida Statutes). { and that the facts in it are true to the best of my knowle Old >- 13_ Cr-C. Signatures)ofOwnet{s or woe e)'Aut(lorizedOfficer/ Director /Partner/Managerwho signed above; ®� -• 2 By y C B tJ Lu L, R".OM9.07 (S.Recording) LU �C- F-- F" "I Co LLI CD 1.41. C*t"'a y Cl3 3001 S.E. Gran Park Way, Stuart, Florida 34997 (772) 287.6476 • (800) 244.4143 • FAX (772) 287.9740 E-Mail: sales@gulfshutters.com www.gulfshuffers.com License #CRC058017 Name �11%11 I .- ORDER FORM Protected by EVALUININUINW& SHUTTER CORP Since 1979 Date D_71/d% 112 Address GV=`- a�i,-� r /� s �;� ��.� C r Subdivision a���� !� R t �� City ' Z State j='�L_ Zip 9� C- Phone (Home) 273 (Work) pp A roximate Installation' OPG OPENING TYPE IOW DTHG I HEIGHT I COLOR PANEOUSLAT GAUGE I STR///LK L/OK R TRACKSI BUILD OUT I CRANK/ I STORM BARS APPLICATION I FLOOR Page I of L Key Storm Panels - SP Accordions - AC Bahamas - BA Colonial - CO Rollups - RU Lexan - LX Garage Brace - GB Application Key Wood - W Block - B Stucco Over - SO :V�N 0004 0 q ',? DEPOSIT 50% BALANCE ON COMPLETION f � v It is understood that there are no verbal agreements and all items discussed are 1-7 11 �`� ` `7 P\J/ .2 covered by this written contract. s is a proposal until signed by an officer of the corporation at which time it t'1 becomes an executed contract. Acceptance by owner must be within 30 days of proposal date. Buyer may / cancel this contract within 3 working days after signing. No changes in measurements will be allowed except at prices mutually agreed upon, at the time these changes are made. Any physical orverbal changes aftersigning must be approved in writing by both parties. All agreements are contingent upon strikes, lockouts, accidents, acts of God, weather, fire, carrier delays, delay or failure to receive raw material deliveries, or by other causes, whether of like or different nature beyond our Electric. Buyer agrees that any necessary electrical connections will be made at the closest souce of power. Any changes or variations will be an additional charge. control. Owner to carry fire, tornado DO NOT SIGN THIS CONTRACT UNTIL YOU HAVE READ ALL CONDITIONS OF THIS AGREEMENT and other necessary insurance. Our workers are fully covered by Interest Buyer agreesXo p r a 1 Yz % per month interest charge on any unpaid balances. Costs of Collection - Buyer agrees to be responsible for seller's attorney's fees (both trial and appeal) Workmen's Compensation Insurance. and all other costs of �o�etion in the eventfull payment as tfined herein is not made within 10 days of the completion of the work outlined herein. Acceptance of Proposal - The above prices, All material is property of Gulfstream a,,,ceto until final payment and can be removed specifications an�co l ns. re satisfactory a hed. You are authorized to d the work as specified. Cancellatio Fee 20 /o of contract. Payment will be made as outlined above. if not paid. Signature Date �/— Sales er's �� / Aj� Date YEAR GUARANTEE p � a� U r '" Gulfstream 40minurn and Shutter Corp. 3001 S.E. Gran Park Way, Stuart, Florida 34997 (772) 287 e 6476 • (800) 244. 4143 FAX (772) 287.9740 E-mail: jobrien@gulfshutters.com www.gulfshutters.com Lic. #MC00231, SL 1211, PB# U-17051 & CRC58017 LAYOUT SHEET Storm Panels - SP Accordions - AC Bahamas - BA Colonial - CO Key Page & of Rollups - RU Lexan - LX Garage Brace - GB :::::::::::::::.:�:::�::;:::::::::::::::r::::::::::;:::::: ..: =� .::::::: ESE;.... ................... � .::.: ......... ....."<...,,<,.< ,..,. ,< ,..,,..,.,,..,<.,...,.,, TN PL4IVSANDALLAROPOSEDW®RK..... ..::: :: ; :: = : :::.:: ' :: :: :: ; :::::ARE SUBJECT M ANY C0R : : : .....................::.:::::';;:;;::;::..;..............::t;............:..::: RECTIONS ....: REQUIRED BY FIELD INSPEM13 THAT . MAY®EMCMARYINQRDR TO:;::;::;::' ::::::,:OA9€R:: -::CONCEAL O ATTA 4ENi :F< , - : :.: :::......:::::::: ;. :............:.............. ::::,:ARE THE:HESPONSIBUTYO�:i1�E ::::::.:::::.:::: :::::::::; :;:: ::�7:;;:<..< „';;': : :-:::::: CONTNACTAR FUCORD::::::: :;: ;::::::::::::::: ........... L i�:.........r� E3Y ; .,<<:::.::::::............... ........::.::: `..;:.:::...:.::::. ";::;;...ST: KEP7"QM:�lOB:O�t: „S CTIDN:W[LL:$E;IMDE:: <"................. :::"::;:::::;;:"":::::; .. . . . ................ Special Instructions: a v+a,� -��� ✓ Nam' f Signature Date Salesperson kg�A.)tiLe 1C 41i , Date Gulfstream Nurninum and Shutter Corp. MIAMIDADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Roller Star Corporation 6351 NW 28 h Way, Suite C Fort Lauderdale, FL 33309 MIAAH DADE COUNTY, FLORIDA METRO -DARE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAIVII, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 SCOPE: >11110111 This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Extruded Aluminum Roll -up Shutter APPROVAL DOCUMENT: Drawing No. 02-435111, titled "RE1500 Extruded Aluminum Roll Shutters", prepared by EngCo, Inc. dated 06/27/02, with no revisions, sheets 1 through 15 of 15, bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami - Dade County Product Control Division. MISSII.E IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the _expiration date or if there has-been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The XOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists -of this page 1 as well as approval document mentioned above. The submitted documentation was reviewed by Candido F. Font, P.E. NOA No 02-1021.03 Y _ Expiration Date: April 10,2008 Approval Date: April 10,2003 Page 1 Roller Star Corporation NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED (For File ONLY. Not part of NOA) A. DRAWINGS 1. Drawing No. 02-435R1 prepared by EngCo, Inc on 06/27/02 sheets 1 through 15 of 15, titled " RE1500 Extruded Aluminum Moll Shutters" signed- and sealed by Pedro De Figueiredo, PE. B. TESTS 1. Test report. on Uniform Static Air. Pressure test per TAS 202-94, Large Missile Impacts test, per TAS 201-94 and Cyclic Wind Loading test per TAS 203-94 of RE1500 Female Slat & Intermediate slat, prepared by Construction Testing Corporation, report No: 02-016, dated 06/28/02 and prepared by Construction Testing Corporation sheets 1 through 8 of 8, signed and sealed by Y. Kuri, PE. C. CALCULATIONS 1. Calculations and design for Slat, Track Anchorage, Track Assembly Screws, Header, Mullion Strom Bars and Analysis of test results, prepared by Engco, Inc, On 06/27/02signed and sealed by P. De Figueiredo PE. 2. Addendum to calculations prepared by Engco, Inc on 09/1210, signed and sealed by P. De Figueiredo, PE. D. MATERIAL CERTIFICATIONS E. STATEMENTS 1. Code compliance. letter issued by Engco, Inc. on 09/12/02, signed and sealed by P. De Figuiredo, PE. 2. No interest letter issued by Roller Star on 10/15/02 and signed by D. Ceccofiglio. Candido F. Font, P. E. Senior Product Control Examiner NOA No 02-1021.03 Expiration Date: April 10, 2008 Approval Date: April 10; 2003- E-1 0 1 i ROLL SHUTTER RE 1500 GENERAL -NOTES, 1- DEFINITION: THIS PRODUCT IS A ROLLING TYPE SHUTTERI DESIGNED, CONSTRUCTED AND ERECTED TO EASILY ENCLOSE AN AREA, PROVIDING PROTECTION -FROM HURRICANE FORCE WINDS WITHIN THE ALLOWABLE DESIGNED PRESSURES AND LIMITATIONS STATED IN THIS APPROVAL. 2- CODEi FLORIDA BUILDING CODE 2001, THIS PRODUCT HAS BEEN TESTED UNDER MIAMI-DADE PA 201, 202 AND 203, THE DESIGN APPLIES TO WIND-BORNE DEBRIS REGIONS (INCLUDING BROWARD AND DADE COUNTIES) IN ACCORDANCE WITH FLORIDA BUILDING CODE 2001, 3- POSTING, A PERMANENT LEGIBLE DECAL SHALL BE PLACED AT A READILY VISIBLE LOCATION STATING THE FOLLOWING: 'RE 1500 SERIES ROLL SHUTTER ROLLER STAR - FT, LAUDERDALE - FLORIDA DADE COUNTY PRODUCT CONTROL APPROVED' 4- LOADS, THE DESIGNED LOAD MUST BE CALCULATED, AS PER ASCE 7-98 (SECTION 1606, FLORIDA BUILDING CODE) BY A PROFESSIONAL ARCHITECT OR ENGINEER FOR EACH SPECIFIC PROJECT, THE CALCULATED DESIGNED PRESSURE MUST NOT EXCEED THE ALLOWABLE PRESSURES FOR EACH SHUTTER COMPONENT TO BE USED, 5- MATERIALr ALL ALUMINUM STRUCTURE AND COMPONENTS SHALL BE DESIGNED AS PER CHAPTER 20 OF THE FBC. EXTRUDED SHAPES SHALL BE MADE OF 6D63-T5 ALLOYS OR AS NOTED. 6- FASTENERS: ASSEMBLY SCREWS AND ANCHORS SHALL BE AS SPECIFIED IN THE CURRENT SET OF DRAWINGS, INSTALLATION AND LOADS AS PER THIS APPROVAL, 7- USE: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, ARCHITECT OR ENGINEER OF RECORD TO VERIFY THE FOLLOWING: 7, 1- THE STABILITY OF THE STRUCTURE WHERE THE SHUTTER IS TO BE ATTACHED INSURING PROPER ANCHORAGE, 7. 2- THE SITE SPECIFIC PROJECT CRITERIA, SUCH AS BUT NOT LIMITED TO, WIND LOADS, LOCAL CODE REQUIREMENTS, DESIGNED PRESSURES ETC, 7. 3- THAT THIS APPROVAL IS ADEQUATE TO THE SPECIFIC PROJECT, SHEET 1 of 15 - COVER SHEET, INDEX, GENERAL NOTES SHEET 2 of 15 - SHUTTER COMPONENTS SHEET 3 of 15 -.SLATS WIND LOAD (TABLES 3. 1, 3,2) SHEET 4 of 15 - GUIDE RAILS MOUNTING OPTIONS SHEET 5 of 15 - STORM BARS SELECTION & DEFLECTION TABLE SHEET 6 of 15 - STORM BARS SELECTION & DEFLECTION TABLE SHEET 7 of 15 - STORM BARS ANCHORING TABLES SHEET 8 of 15 - HEADER SELECTION & DEFLECTION TABLES SHEET 9 of 15 - HEADER SELECTION & DEFLECTION TABLES SHEET 10 of 15 - HEADER ANCHORING TABLES SHEET 11 of 15 - MULLION SELECTION TABLE SHEET 12 of 15 - MULLION ANCHORING TABLES SHEET 13 of 15 - HOOD ASSEMBLY _ SHEET 14 of 15 - SLATS DEFLECTION TABLES (14, 1, 14, 2, 14, 3, 14, 4) SHEET 15 of 15 - COMBINED DEFLECTION ON MULTIPLE SPANS SHUTTERS Approved as complylagwBh eta slorma , la c Date 4 NOL - O Metal Dade Product Coalral Divleloa By Manufacturer. Roller Star 6351 NW 28th WAY FT. LAUDERDALE, FLORIDA - 35309 Tel.: (954) 972-4772 Product: RE1500 EXTRUDED ALUMINUM ROLL SHUTTERS Engineering: s`EngTo Jnr. CA 8116 6971 W. Sunrise Blvd. 104 Plantation, FI. 33313 Tel.: (954) 585-0304 •l >:EB.1 0 2003 Engineer Seal Pedro Do Flguelndo PE 52609" Date: 6/27/02 Scalia: 1:1 Design by: PPMF Dade County NO& Drawing Number 02-435R1 Sheet 1 of 15 2.47 till 1- RE-1500� o FEMALE SLATar 6063-T5 2.47 -' 1,145 �-- N 0 Ln 0 IA- RE 1500VP WINDOW VIEW SLATS - 6063-T5 78 In nl \ o R o - RE-1500 ]NTERMEDIATE SLAT - 6063-T5 3.100---4 M d T o� i O BASWAT5 0 SILL SLAT 1 6063-T5 ��-3.093—� N m 1.540--I (U In 4- GUIkS24, c GUIDE RAIL6 - 6063-T5 3.872--i tn a E --I 5- GUIYS26 c GUIDE RAIL-.6063-T5 1,250 m O 0 6- 3/16 X 1 1/4' POLYCARBONATE SHEET T [ll N 7- 1/8'-2X2 ALUMINUM ANGLE 7o- 3/16'-2X2 ALUMINUM ANGLE 7b- 1/4'-2X2 ALUMINUM ANGLE 6063-T5 OR 6063-T6 8- 1/8- 2X2. 8A- 1/8- 2X3 8B- 1/8- 2X4, 8C- 1/8- 2X5 8D- 1/8- 2X6 ALUMINUM TUBES - 6063-T6 (TO BE USED AS STORM BAR, HEADER, MULLIONS AND BUILT -OUT) • 1/8-2X6 TUBE IS NOT USED AS STURM BAR SHUTTER COMPONENTS rSINGLE SPAN . TWO SPAN HEADER HOOD OPTIONAL TRACK WINDOW SLAT IA J SLATS SLATS STORM BAR BASIC C❑NFIGURATI❑NS . O� 1r tv 1X6 SLOT bs EVERY 7' OC 3/16' PDLYCARBONATE .56 PLATE INSERT RE 1500VP WINDOW VIEW SLATS .05 EXTRUDED ALUMINUM 6063-75 Alloy / NOTE- MAXIMUM 2 SLATS PER DOOR + Manufacturer - Roller Star 6351 NW 28fh WAY FT. LAUDERDALE. FLORIDA — 33309 Tel.: (954) 972-4772 THREE SP.AN, HEADER Pr6duct: _ RE1500 _ _ = EXTRUDED• ALUMINUM ROLL SHUTTERS SLATS STORM BARS Engineering: Eng(go Jnr. CA 8116 6971 W. Sunrise Blvd. 104 Plantation, FI. 33313 Tel.: (954) 585-0304 RE 1500 SLAT - SLOT CONFIGURATION ALL INTERMEDIATE SLATS WITH SLOPS Approved as iloo Miammhe da DetdANOAk i Dade et Central DI'Lfaa 9y I FEB 10 2003 . I Engineer Seal Pedro De Figuelrado PE 52609 I Data: 6/27/02 I Soale: 1:1 /2 Design by: PPMF Dade Countv NOA: Drawing Number 02-435R 1 Sheet 2 of 15 GUIDE RAILS MOUNTING OPTIONS IM ❑DR T—W7�L L� Edge Dlst. Wall Dresssing DESIGNED PRESSURES a A a. Sup. Struct a a ANCHOR SPACING S24 12 . * IANCHORUAQ 45 e6SM 145 <=210 ANCHOR B no no 30 <=115 ANCHOR C 45 75 145 <=210 S26 12 9 6 3 ANCHOR A 45 55 95 <=210 A CHOR B no na -3 <= 85 ANCHOR C 30 55 105 <=210 M❑UNTIBUILT-❑UT Edge Dlst, Wall I:--- —_4 I..- Dresssing DESIGNED PRESSURES ALUM. TUBE _T-OUT 14X1 SELF DRILLING SCREW ?ACED1 3' OC UP TO 210 PSF 6.00 UP TO 155 PSF 9' QC UP TO 85 PSF 12'13C UP TO 55 PSF ANCHOR SPACING ANCHOR A 65 95 <=210 ANCHOR B no 30 55 <=155 ANCHOR C 65 105 <=210 - S26 12 9 6 3 ANCHOR A 45 65 135 <=210 ANCHOR B no no 30 <=115 ANCHOR C 45 75 145 <=210 ANf'klrlp lzrlwpnlll 1- Manufacturer. Roller. Star 6351 NW 2811h WAY FT. LAUDERDALE, FLORIDA - 33309 Tel.: (954) 972-A M❑UNTi INSET 30D SERIES 1/4'-20 SS BOLT & NUT Di3'OC UP TO 210 PSF 6'13C UP TO 155 PSF Product: 9'13C UP TO 85 PSF RE 1 5 0 0 12'11C UP TO 55 PSF EXTRUDED ALUMINUM ROLL SHUTTERS DESIGNED PRESSURES ANC OR SPACING 4 12 9 1 6 1 3 4NCHOR A 30 55 95 <=210 4NC OR B no no 30 <=105 4NCHOR C no 30 75 <=210 S26 12 9 6 3 4NCHOR A no 45 85 <=210 n 30 <= 4NCHOR C no 30 65 <=210 CONT. 2X2 ALUM. ANGLE DESIGN PRESSURE Sha a S24 Track S26 Track 6063-T5 6063-T6 6063-T5 6063-T6 1/8 -2x2 41 75 27 55 3/16-2x2 135 1210 100 1 210 / -2X2 210 1 - 210 - Notelvalues cpntrolled by the span vs pressure tables on sheet 3, ANCHORAGE NOTESi 1- ANCHOR SPACING IS CONTROLLED BY THE SPAN VS PRESSURE TABLES ON SHEET 3. 2- no - NOT AVAILABLE 3'%W�CllsreS AwL zfteEo oW'mF MwXltfcM rawkeO R.6+u,StoN ¢vuv6Dw eF T6gLft3.1k9.' ca1AW 3• Type Description Embedment Substrate Manufacturer A 1/4' Ta con 1 3/4' 3000 psi Concrete Elco 1/ ' Tn con 1 1/41 HoLtow Btocktco C #14 SS Wood Screws 2' Wood (SG=.55) Elco EDGE DISTANCE =3' Engineering: FngTo Jnr. CA 8116 6971 W. Sunrise Blvd. 104 Plantation, Fl. 33313 Tel.: (954) 585-0304 FED 1 0 2003 Engineer Seal Pedm De Flguelndo PE 52609 Date: 6/27/02 Scale: NA Design by: PPMF Dade County NOA: Florida Cui:::pxlCoGp_ 11virlon// s� I Drawing Number 02-435R1 Sheet 4 of 15 1- STORM BAR ANCHORAGE WALL MOUNTED STORM BARS WALL MOUNTED STORM BARS ANCHORED TO CONCRETE OR WOOD ANCHORED TO HOLLOW BLOCK WALL 2 ANCHORS TYPE A OR C PER EA CLIP -r ® 0. 0 fL f ® 3 ANCHORS 1 0 TYPE B PER EA CLIP _I/B'-2X2ALUM, 1HOLLOW CLIP 1/8'-2X2 ALUM. CLIP #12-14x7/8' DRILLFLEX #12-14x7/8' DRILLFL SCREWS BY ELCO 2 PER CLIP 3000 PSI CONCRETE SCREWS BY ELCO OR PER CLIP BLOCK WOOD STRUCTURE2 Arorw o QI WC'T1l N C GENERAL NOTE, ALL ANCHORAGE IS CONTROLLED BY THE MAXIMUM STORM BAR HEIGHT SELECTION TABLES ON SHEETS 5 AND 6 STORM BARS MOUNTED ON BUILT -OUT ALUM. TUBE AND SHUTTER HEADER SEE TOP/BOTTOM BUILT -OUT BUILT -OUT ALL ,�rl TUBE ANCHORAGe' �I {{ SEE TABLE 2 #12-14x7/8' DRILLFLEX SCREWS BY ELC 4 PER CLI TOTAL 8 SCREWS SEE TOP/BOT OM O O BUILT -OUT AL M. TUBE ANCHOR El FLOOR/CEILING MOUNTED STORM PARS ANCHORED TO CONCRETE SLAB FIGURE 1 2 ANCHORS TYPE A PER CLIP y = aw Nat span span Storm Bar :• "•.•• z Tributary Aren ..� w #12-140/8' DRILLFLEX SCREWS BY ELCO 2 PER CLIP 2•X I ALUM. X2 �j ALUM. f -- ALUM. CLIP TUBE Type Description Embed Substract iftnufacturer A 1/4' Tn con 1 3/4' Concrete Lco 4' a on 1 o Low BLo k I Eico C #14 SS Wood Screwsl 2' 1 Wood ( SG=. 55)1 ELco EDGE DISTANCE =3' TABLE 2 ALLOWABLE DESIGNED PRESSURES CPsf) CLlp Size Pd Psf (w> 2 <_ 1,51 3' <=2 . 5' 4' <= 10 3, 0' 5' <=210 1 4.0' Pal Allowable designed pressure N T T m °• N �7i um J STORM BAR-' TYPICAL 1/8-2X2 ALUMINUM CLIP TYPICAL _#12-14x7/8' DRILLFLEX SCREWS BY ELCO 2 PER CLIP 1112-140/8' DRILLFLEX SCREWS BY ELCO 3 PER CLIP - TOTAL 6 SCREWS TABLE 1 ALLOWABLE DESIGNED PRESSURES CPSF) 2 SPAN -CLIP SIZE 1 3 SPAN -CLIP SIZE 2 3 4 5 4 5 79 123 184 204 90 139 209 232 53 82 122 136 60 93 139 154 39 61 92 102 45 70 104 116 E4O 26 41 61 68 30 46 70 77 23 35 52 58 26 40 60 66 20 31 46 51 22 35 52 58 1.5 1-:USE 2 ANCHORS PER CLIP 2 AFI SEE FIGURE 1 TO CALCULATE AREA 3- USE ANCHOlt TYPE A. TOP/BOTTOM BUILT -OUT ALUMINUM TUBE ANCHORAGE CLUSTER OF ANCHORS TYPE A- MIN. OF 3 ANCHORS TYPE B- MIN. OF 6 ANCHORS TYPE C- MIN, OF 3 ANCHORS BARS TUBE BUILT -OUT TOP & BOTTOM Manufacturer. Roller Star 6351 NW 2Bfh WAY FT. LAUDERDALE, FLORIDA - 33309 Tel.: (954) 972-4772 Product: RE1500 EXTRUDED ALUMINUM ROLL SHUTTERS Engineering: Engav - Jnc. CA ails 5971 W. Sunrise Blvd. 104 Plantation, Fl. 33313 Tel.: (954) SB5-0304 FED 10 2fl03. Engln"r Seal "Pedro Do Flguliirodo PE 52609 Date: 6/27/02 Scale: NA Design by: PPMF Dade County NOA: Approved = complying rrlth the Fbrldu BuO C de Date O NOAH _ O o Miami Dude uct Control Division By Drawing Number 02-435R1 Sheet 7 of 15 ANCHnp zrPr7 I II P- Type, Description Embed, Substract Manufacturer A 1/4' Tn con 1 3/4' Concrete Elco /4' Topcon 1 1/ ' Hotiow Block Etco C #14 SS Wood Screws 2' Wood (SG=.55) Elco EDGE DISTANCE =3' ANCHORAGE NOT HEADER ANCHORAGE IS CONTROLLED BY THE MAXIMUM ALLOWABLE STORM BARS HEIGHT TABLES ON SHEETS 5AND 6 HEADER ANCHORAGE INTO MULLION TUBE NOTEi INSIDE HEADER IS OPTIONAL, INSIDE STORM BARS CAN BE ANCHORED TO CEILING OR WALL, L ACCESS HOLE W/ PLUG (2 PER CLIP) \'_1/4-20x1k HWH #4 DRILL -FLEX BY ELCO (4 PER CLIP) (2 PER END) 1/4-2041' HWH #4 1/4-20x2' HWH #4 DRILL -FLEX BY ELCO DRILL -FLEX BY ELCO "'�1/8' ALUM. TUBE MULLION SEE MULLION DESIGN SHEETS FOR DETAILS. H ANCH 'ABER IRAGE 3 SPAN HEADER--2 Span 1 Span Span SPAN HEADER Span Span N SH - SHUTTER HEIGHT SBH - STORM BAR HEIGHT HEADER ANCHORAGE HEADER ANCHORAGE INTO BUILT —OUT ALUM.- TUBE OUTSIDE HEADER N SE mo ce d� MCI Q� ACCESS HOLE W/ PLUG - a (2 PER CLIP) 1/4-2DxIj' HWH #4 DRILL -FLEX BY ELCO (2 PER END) 1/4-20x2' HWH #4 DRILL -FLEX BY ELCO 1/8' ALUM. TUBE BUILT -OUT Manufacturer. Roller Star 6351 NW 28th WAY FT. LAUDERDALE, FLORIDA - 33309 Tel.: (954) 972-4772 Product: RE1500 EXTRUDED ALUMINUM ROLL SHUTTERS Engineering: +Ernlq(6u .Jnr. CA 8116 6971 W. Sunrise Blvd. 104 Plantation, Fl. 33313 Tel.: (954) SSS-0304 FEB412661.' Engineer S.ol Pedro D. Figudredo PE 52609 Date: 6/27/02 Scale: NA Design by: PPMF Dade County NOA: Approved as comply)ag vdtb the Rodda BeWMz 4ale1_ — Drawing Number 02-435R 1 Sheet 10 of 15 1/2' HOOD - 6 3/E —7' HOOD - 7'- -8' HOOD - 8'— .0' HOOD - 9 7/8'- 2' HOOD - 11 7/B' i' HOOD - 15 5/8' THICKNESS .032 - 6 1/2', 7' .04 - B', 1D', 12' OS - 15 3/4' THICKNESS .032 - 6 1/2', 7' D4 - 8', 10', 12' .05 - 15 3/4' a' N Cy lna I 1 I 1 1 I U U U U LLj Ld Ld 1¢i � !L N N N Ibi (aB ° W11j 7/B' 6 11/16' 5 5/16' 4 3/4' ,Ltiti ,L 3 7/8' 3 3/8' HOOD ASSEMBLY e�1P Pyy Geec Pop RWet 6 / L'i 0 1exVV Sheet Mtt ftmv End Cap Neck Manufacturer. Roller Star 6351 NW 28th WAY FT. LAUDERDALE, FLORIDA - 33309 Tel.: (954) 972-4772 Product: RE1500 EXTRUDED ALUMINUM ROLL SHUTTERS Engineering: iEttgCga 3ttr. CA 8116 6971 W. Sunrise Blvd, 104 Plantation, Fl. 33313 Tel,: (954) 585-0304 'EB 10 2009 .. EngIn"; seal .. Pedro De In"; PE 52609 Data: 6/27/02 Scale: NA Design by: PPMF Dade Country NOA: APWm'eei Drawing Number 02-435R 1 Sheet - 13 of 15 GUI*52:4 GUIDE RAILS r---3,093---{ T a) 1540--I L c GUI*S26 GUIDE RAILS '- 3.872� a 'F 2,320 - --� m 6 0 SLATS DEFLECTION TABLES TABLE 14,1 TABLE 14,2 SLAT DEFLECTION FOR 2 SPAN SHUTTERS SLAT DEFLECTION FOR 3 SPAN SHUTTERS SHUTTER SPAN Pd 84 78 72 66 60 > 5 48 40 30 1, 18 0, 88 U. 64 U. 45 0. 31 0, 20 0, 1.3 0.06 ii1445, 1. 77 1. 32 0796 0, 67 0. 46 d ag 0. 19 0 55 no 1. 61 1. 17 0, 82 07 56 0, 37 0, 23 76'--1-1- 65 no 1. 90 1, 38 CT 97 9 67 0, 44 0. 27 0, 13 na na 85 na na 1, 80 1. 27 0. 8 0, 57 0. 36 0. 17 95 na na na 1, 42 0, 97 0, 64 0, 40 0, 19 105 na no no 1, 57 1.08W40 0. 21 115 na na no 1. 72 1, 1 0.23 125 na no no 1, 87 1.28 0.25 135 na no no no 1, 3 0. 27145 no no na no 1, 41 0, 29 155 no no na no ]. 59 1, 04 0, 65 0, 31 165 no no no no 1.69 1.11 0, 69 0. 33 175 no no no I na 1. 79 1, 18 0, 73 O, 35 165 no no na no 1. 89 1, 24 0. 78 0. 37 195 na no na na 2. 00 CIE 0, 82 0, 39 210 1 no no no] nal no 1. 4110. 88 U 42 Deflections are Indicated In Inches TABLE 14, 3 SLAT DEFLECTION FOR 2 SPAN SHUTTERS SHUTTER SPAN Pd 1 84 1 78 72 66 60 54 48 40 30 1, 34 10. 99 0, 72 0. 1 0, 35 0, 23 0, 14 0, 07 45 na 1. 49 1. 08 0. 76 0. 2 0, 34 0.21 0. 10 55 na 1. 82 1, 32 0. 93 0. 64 0, 42 0.26 01, 13 65 na na 1. 56 1. 10 0. 5 0, 49 0. 31 0. 15 na na T 85 no no na 1, 44 0. 99 0, 65 0, 40 0, 19 95 1 no no I no 11. 61 1, 10 0, 72 0. 45 0, 22 105 1 no I no na 11. 78 .1. 22 0. 80 0, 5010, 24 115 na I no na 11. 95 1, 33 7 87 0. 5510, 26 125 no no no I na T 45 0. 95 0. 5910, 29 135 no no no I no, 1. 57 1, 03. 0. 6410. 31 145 na no no, I no, T. 68 1. 10 0. 6910. 33 155 no no na na 1. 80 1, 18 0. 7410, 35 165 no na na na 1, 91 1. 2610. 78 0, 38 175 na na I no I na na 1. 3310. 83 0.�42 185 no na no na no 1, 41 0. 88 0.195 no na na na na 1. 48 0, 93 0.210 no na no na no I, 60 1. 00 0, Deflections are Indicated In Inches SHUTTER SPAN Pd 84 1 78 72 66 60 54 48 40 30 1. 51 11. 12 0, 81 0, 57 0; 39 -(T-2-6 0. 16 0, 08 45 no 11. 68 1, 227. 86 C 59 0,.39 0, 24 0. 12 55 no, I no 1, 49 1. 05 0, 72 -T 47 77 29 0. 14 65 no, I na 1. 76 T. 24 0, 85 0, 56 0. 35 0, 17 na na na 85 no no no 1, 63 T. 11 0, 73 0, 46 0, 22 95 no no no I. 82 1. 24 0. 81 0, 51 0.25 105 no na no no 1, 37 0, 90 0. 56 0. 27 115 no na no no 1, 50 0. 99 0.62 0.30 125 no no na no 1, 63 1, 07 0.67 0.32 135 na na na na 1. 76 1. 16 o 7 72- 0. 3 145 1 no no no no 1, 90 1, 24 0.78 0. 37 155 na na no no no 1, 33 0, 83 0, 40 ] 5 no no no no, na 1. 42 0. 88 0. 43 175 na _ no na no no 1, 50 0. 94 0. 45 185 no no no no na 1, 59 0.99 0. 48 195 no na na no na 1. 67 1.04 0 550 210' na no no no na no 1. 12 0, 54 TABLE 14, 4 SLAT DEFLECTION FOR 3 SPAN SHUTTERS SHUTTER SPAN Pdj 84 178 1 72 1 66 1 60 54 48 40 30 1. 71 1. 27 10. 92 1 U. 65 0, 44 0. 29 0, 18 0.09 4 no 1. 90 1. 3810. 98 0, 67 0, 44 0. 27 071 55 , no not I 1. 6911. 19 0, 81 0. 53 933 9 16 65 na na 11. 9911. 41 0. 96 0, 63 9739 0. 19 no na I na 1, 63 .11 85 no nal no 1, 84 1, 26 0, 83 0, 52 0. 25 95 na no na no 1, 41 U. 92 0. 58 0. 28 105 no na no na 1, 55 1, 02 0, 64 0. 31 115 1 na no no na I 1, 70 1. 12 0, 70 0, 34 125 1 no no na no 1 -1 . B5 1, 21 0. 76 0, 37 135 1 na no no no 12, 0 -1 , 31 0. 82 0, 39 145 na no Inal no no 1. 41 0, 88 0. 42 155 no no na I no no 1, 51 0, 94 0, 45 165 no na no no no 1. 60 1. 00 0, 48 175 na no no no no 1, 70 1. 06 0, 51 185 na no no no no 1, 80 1, 12 0, 54 1 5 no na na no no na 1. 18 0. 57 210 na no na na na na 1.27 0. 61 Manufacturer: Roller Star 6351 NW 28th WAY FT. LAUDERDALE. FLORIDA - 33309 Tel.: (954) 972-4772 Product: RE1500 EXTRUDED ALUMINUM ROLL SHUTTERS En J(so Jxcr CA 8116 6971 W. Sunrise Blvd. 104 Plantation, FI. 33313 Tel.: (954) 585-0304 FEB 10 ZUUJ Engineer Seal' Pedro De Figuairedo PE 52609 Date: 6/27/02 Scale: NA Design by: PPMF Dade County NOA: APPro,+1--, 'gWiththe Florida Raiding Obde/_ _ Drawing Number 02-435R 1 Sheet 14 of 15 (7 MULTIPLE SPAN SHUTTER SLAT TOTAL DEFLECTION POSITIVE LOAD (1) (2) (3) (4) (5) (6) (7) (W (9) (10) UNIT # Pd TT # SPANS Span SLAT DEF(A). STORM BARS. HEADER TOTAL DEF.(D) D=A+3/2+C/4 Allowable D<=Span/30 or 2' US GS=33+1 TYPE SPAN DEF.(B) TYPE DEF.CC> 1 2 3 4 5 6 NEGATIVE LOAD C1) (2) (3) (4) (5) (6) ­_-ST15RUT (7) (8) (9) UNIT # Pd TT # SPANS Span SLA DEF(A). BARS HEADER TOTAL DEF.(D) D=A+B/2+C/4 Allowable D<=Span/30 TYPE SPAN DEF.(B) TYPE I DEF.CC) 1 2 3 4 5 6 PROCEDUREt STEP 11PROVIDE PROJECT DESIGNED PRESSURE IN PSF AS PER -ITEM 4 SHEET 1 OF 15 BASED ON ASCE 7-98 STEP 21PROVIDE TRACK TO TRACK SHUTTER DIMENSION IN INCHES, STEP 31PROVIDE NUMBER OF SPANS, 2 FOR ONE SET OF STORM BARS 3 FOR TWO SETS, STEP 41CALCULATE THE SPAN SIZE DIVIDING TT/# OF SPANS, THIS VALUE MUST BE LESS OR EQUAL THE CORRESPONDING VALUE OF TABLE 3. 1 OR 3, 2 ON SHEET 3 OF 13. - STEP 51CALCULATED SLAT DEFLECTION IN INCHES AS PER TABLES ON SHEET 14 OF 15 ' STEP 61SELECT APPROPRIATE STORM BAR TYPE AND CORRESPONDING DEFLECTION ON SHEETS 5 OR 6 I3F 15. STEP 7i(IF APPLICABLE) SELECT APPROPRIATE HEADER TYPE AND CORRESPONDING DEFLECTION ON SHEETS 8 OR 9 OF 15, STEP 81CALCULATE TOTAL DEFLECTION / STEP 91CALCULATE AND COMPARE MAXIMUM ALLOWABLE DEFLECTION. IF TOTAL DEFLECTION EXCEEDS THE ALLOWABLE TRY TO UPGRADE THE STORM BAR UNTIL DESIGN IS ACCEPTABLE. / STEP 10iCALCULATE THE SLAT TO GLASS SEPARATION (POSITIVE ONLY). COMPARE WITH GLASS SEPARATION TABLE. •/ NOTESt A- USE ADDITIONAL SHEETS IF PROJECT HAVE MORE THAN 6 SHUTTERS.' B- THE MAXIMUM ALLOWABLE DEFLECTION MUST COMPLY WITH SECTION 1612.1 OF THE FBC 2001. TWO SPANS INSIDE TRACK DIMENSION (TT) BAR THREE SPANS INSIDE TRACK DIMENSION (TT) ( GS) GLASS 'U'PADATTONI LARGE IMPACT SPAN WIND LOAD ONLY 3' SPAN) 52' 3' 2 3/4' 411'<SP' N<=52' 2 3/4' 2 3/B' SPAN<=40' 2 3/B' GLASS SEPARATION FOR LARGE MISSILE IMPACT IS APPLICABLE FOR INSTALLATION UP TO 30 FT. OF GRADE DUE TO LARGE MISSILE IMPACT, WIND LOAD GLASS SEPARATION APPLIES TO INSTALLATION ABOVE 30 FT. OF GRADE, Manufacturer. Roller Star 6351 NW 28th WAY FT. LAUDERDALE, FLORIDA - 33309 Tel.: (954) 972-4772 Product: RE1500 EXTRUDED ALUMINUM ROLL SHUTTERS Englneering: �En�C�u Jrtr. CA 8116 6971 W. Sunrtee Blvd. 104 Plantatlon, Fl. 33313' Tel.: (954) 585-0304 FEB 10 2003 Engineer Sea[ Pedro Do Figutdndo PE 52000 Date: 6/27/02 Scale: NA Design by: PPMF Dade County NOA: Approved as complying with the Florida Bo131a / 1, O Date i� NOAH Miami Dad nclCootrel Divislo Drawing Number 02-435R1 Sheet 15 of 15 BCIS Home 1 Log In I Hot Topics 1 Submit Surcharge ! Stats & F luct.Approval Public User Publications ' FBC Staff ! BCIS Site Map I Li, Product, Approval Menu > Product or.ApPlication Search > A _ Ilcation List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative a Address/Phone/Email w -=,fir, t. I>se _ :."�...>n•Quality Assurance Representative Category Subcategory FL389-RI Revision 2004 Approved C-1 American Shutter Systems Association, Inc. 4268 Westroads Drive West .Palm Beach, FL 33407 (561) 841-5480 bfeeley@easternmetal.com Bill Feeley bfeeiey@easternmetal.com Shutters Accordion Compliance Method Evaluation Report from a Florida Registered Architec Licensed Florida Professional Engineer i_i Evaluation Report - Hardcopy Received Florida Engineer or Architect Name Walter A.. Tillit,.]r. P.E. who developed the Evaluation Report Florida License, PE-44167 .//www.floridabuilding.org/pr/pr__app AtlIspx?param=wGEVXQwtDgvYYM �4vx53MwsXdC.OtO... 3/17/2006 Quality Assurance Entity Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved National Accreditation and Management Institute John Henry Kampmann Jr. Standard ASTM E-1886 ASTM E-1996 1609.1.4 1609.1.4 Method 1 Option D 8/5/2005 9/23/2005 9/29/2005 10/11/2005 FL # Model, Number or- Name 389.1 Bertha HV Accordion Shutter (Non-HVHZ)- Drwg #05-196 Limits of Use Approved for use in HVHZ: Approved for use outside HVHZ: Impact Resistant: Design Pressure: +/- Other: This product shall not be installed within High Velocity Hurricane Zone as defined on section 1620.2 of the Florida Building Code.. Year 2002 2002 Extruded aluminum interlocking blades i by tracks (top and bottom) for storm pr. Enstallation Instructions Verified By: Evaluation Reports PT_ID_389 R1 T CERT INDEPENDENCE PTID 389 R1 T Drawing N0.05-196._pt PTID 389 R1 T PROD EVALUATION._.R Back Next DCA Administration Department of Community Affairs Florida Building Code Online Codes and -Standards: 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 J/www.floridabuilding.org/pr/pr app_4t' ,-ispx?param=wGEVXQwtDgvYYHH -- `svx53MwsXdCOtO... 3/17/2006 1. BERTHA H.V, ACCORDION SHUTTER SYSTEM SHOWN ON THIS PRODUCT (P.E.D,) HAS 6EEN VERIFIED FOR COMPLIANCE IN ACCORDANCE WITH THE 2004 EDITION OF THE BUILDING CODE. EVALUATION DOCUMENT THIS ACCORDION SHUTTER SYSTEM SHALL NOT BE INSTALLED AT HIGH VELOCITY HURRICANE ZONES. ORIOA DESIGN WIND LOADS SHALL BE DETERMINED AS PER SECTION 1609 OF DIRECTIONALITY FACTOR Kda 01 B5O INACCORDAN DICWITHTION ASCE 7S9gTTER WILL IN ORER D. VERIFY THE JURISTHE ABOVE MENTIONED CODE FOR A THAT ANCHORS ON THIS P.A.D., AS TESTED, WERE NOT OVERSTRESSED.WLL BE INSTALLED, AND FOR A ALLOWABLE LOADS FOR WIND, LOADS WAS VERIFIED H.V. ACCORDION SHUTTER SYSTEM'S ADEQUACY FOR WINDANDIMPACT' LOAD HAS IN USED IN THEIR ANALYSIS. VERIFIED IN ACCORDANCE #0214,01 WITH SECTION 1609,1.4 OF THE ABOVE MENTIONED CODE AS PER ATL REPORTS -03 AND #0715.01-03 AS PER TAS-201, TAS-202 AND TAS-203 PROTOCOLS AND AST AND E-1996 STANDARDS. M E-1888 2. BERTHA H.V, ACCORDION PINS (HV SCREWS) USED RESPECTIVELY, 410-HT MINIMUM SERIES STAINLESS STEEL USED AT BLADES KNUCKLE AND FOR DIRECT MOUNT CONNECTION TO TRACKS SHALL BE if 14X2 75 AND 14%1, SCREWS WITH 135.0 ksi YIELD STRENGTH AND 180 ksi TENSILE STRECHT. PINS SHALL BE COATED WITH BERTft4 LDeCOATING CTURED AMERICAN SHEUTTER SYSTEMS ASSSOCI S MANU A MUST gY APPROVED COATING APPLICATORS, REGISTERED WITH HV 3. ALL EAR THE MARKING ON THEIR HEAD. ALUMINUM EXTRUSIONS SHALL BE ALUMINUM ASSOCIATION 6083-TB ALLOY AND TEMPER, WITH FY - 25.0 kal MINIMUM (UNLESS OTHERWISE NOTED), 4. ALL SCREWS TO BE STAINLESS STEEL 304 OR 316 AISI SERIES OR CORROSION RESIST STEEL AS PER DIN 50018 WITH 50 ksi YIELD STRENGTH AND 90 ksi TENSILE STRENGTH, 5. BOLTS TO BE ALUMINUM ASSOCIATION 2024-T4 ALLOY AND TEMPER ANT COATED CARBON AISI 304 SERIES STAINLESS STEEL WITH 35 ksi MINIMUM YIELD ASTM A-307 GALVANIZED STEEL, OR 6. SEE SHEETS 10, 11 AND 12 FOR ANCHORS SPECIFICATIONS,ENGTH, 7. THIS BERTHA H.V. ACCORDION SHUTTER SYSTEM IS PATENT PENDING. COMPONENTS OF THIS APPROVAL ARE COVERED, IN WHOLE OR IN PART BY U.S. PATENT ISSUED TO EASTERN METAL SUPPLY, INC. 8. fT SHALL BE THE RESPONSIBILITY OF THE' CONTRACTOR TO VERIFY THE SOUNDNESS OF THE STRUCTURE ARE-SHUiTEiT t5-T6 BE ATT�IOHEB ifr iNSt1RE pROpNCHORAeE CONTRACTOR TO SEAL/CAULK ALL SHUTTER COMPONENT EDGES WHICH REMAIN, THRU FASTENING IN CONTINUOUS CONTACT WITH THE BUILDING TO PREVENT WIND/RAIN INTRUSION. 9 • EACH UNIT MUST BEAR q PERMANENT LABEL N A VISIBLE PLACE W WARNING NOTE INSTRUCTING THE TENANT OR HoeeE OWNER THAT THE H.V. LOCKdOR ALTERNATE LOCK DURING PERIODS OF HURRICANE WARNING. FOR EGRESS CO MUST REMAIN IN THE LOCK), AN INSIDE ALTERNATE LOCWHERE KEY K �j DTIONS, MUST BE PROPERLY LOCKED OR OCK AN EGRESS H.V. LLOCK $(SHALL BE USED. 10, SHUTTER'S MANUFACTURER LABEL SHALL BE PLACED ON A READILY VISIBLE LOCATION, ONE LABEL SHALL BE PLACED FOR EVERY OPENING. LABEL SHALL READ AS FOLLOWS: A MEETRICAN SHUTTER SYSTEMS ASSOCIATION INC. M FLORIDA (ATEV E' S`PRODUCT APPROVED. 11, BERTHA H,V, ACCORDION SHUTTER SYST'S INSTALLATION SMALL COMPLY WITH SPECS INDICATED IN THIS, DRAWING PLUS ANY BUILDING ANDZONING REGULATIONS PROVIDED BY THE JURISDICTION WHERE PERMIT IS APPLIED To, 12. (c) THIS P.E,D. PREPARED BY THIS ENGINEER IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. WHERE THE SITE CONDITIONS DEVIATE FROM THE P.E.D. (6) CONTRACTOR TO BE RESPONSIBLE FOR THE SELECTION, PURCHASE AND INSTALLATION INCLUDING LIFE SAFETY OF THIS PRODUCT, BASED ON THIS P.E.O., PROVIDED HE/SHE DOES NOT DEVIATE FROM THE CONDITIONS DETAILED ON THIS DOCUMENT. CONSTRUCTION SAFETY AT SITE IS THE CONTRACTOR'S RESPONSIBILITY. (c) THIS P.E.D:'WILL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. (d) SITE SPECIFIC PROJECTS SHALL BE PREPARED BY A FLORIDA REGISTERED ENGINEER OR ARCHITECT WHICH WILL BECOME THE ENGINEER OF RECORD (E.O.R,) FOR THE PROJECT AND WHO WILL BE RESPONSIBLE FOR THE PROPER USE OF THE P,ED. ENGINEER OF RECORD, ACTING AS A DELEGATED ENGINEER TO THE P,ED. ENGINEER SHALL SUBMIT TO THIS LATTER THE SITE SPECIFIC DRAWINGS FOR REVIEW, (e) THIS P.E.D. SHALL BEAR THE DATE AND ORIGINAL SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER OF RECORD THAT PREPARED IT. '; 5�-�; IL ECO�N�. J41 H 1. . r TILUT TESTING & ENGINEERING e35s NG COM -' .•'!: '�-' = N.V. 36& s1, St. 307. YROiNN GWCtNS, FM84 331 PI1aN - 30s1571-1530 . Fee: e. L (3051W1-1531 - �- tiqq++p`w�nn`,��s'.,4�?;1 •,. YT7irJiL4'�.. -` .—mall: Ult... 0.&,c 000e719 P.E. SEQSIGWATURE/DATE WALTERHA r T �� E, RCNIqA U. 6`7 F.B.C. Hon Nigh Velocity Hurricane Zone) 0 2003 EASTERN METAL SUPPLY, INC. //�� BERTHA HV TM American Shutter SI)raterna �' S ■�I" Accordion Shutter System m AnvOClar,, " tlone Inc, oc'c"P"0N lutt 0—n ,xS. 4268 Westroods Drive 1 m' °' 01i '/"/w DATE: Ywo5 West Pc)IM Beach, FL 33407 DRAWING No US-196 aS ; 4 37 85 COVERED UNDER US 5458179 OHD 2' (MOX.j B 0 HEADE(i/gI�L� 3 00' F fO HV_`._AD � 'ADAPT R �;t/I la VARIES 2' 16' ac O n c 090' n m N •�: • • Y �( 1P QN H.V. 2' fMax) DIRECT MOUNT c 1 917' m 0 fi0• n a. 670 •1668' 0 3.520' ' O8 'HV CEII IN(` ur�nrs Cliy 1 (Ma l 81D' HEADE�5ILL +1i (02 a o 4 J ' OHSLI�AI.K—ovER TRAM N Y .062' o OHV CEMTFDusrr 3 (SELF`MgTING) .250- TYP. g K 3.000' 125 TTP. N PATES FR 3M 2.000' TO Sea0' ©B.0 WA AN I F • .... - TILLIT TESTING h ENGINEERING COMPANY , 1. ,f B 1 0353 A.W. JULsL, s1.. gas, Wfanu cu+oEXs. FL..- ]]fee Ph— (J05)671-1530 Fa. ; (]US1671-1531 • 7 Ee fi9aa7ta P.E. •Spy -�"4+J 11�[1 {LATE WALTER A TO11T L. P. E. FLORJDA ua. / 44167 936' a 67a • EQHD CEILIur. uaADER/S!LL s " a9 i' I 00' 0 • 9 QK HV 9D'/t M sTARM (�) HV CORNER r.FNT RMATF " S)MMU POST A.S.S.A. American Shutter Systems Association. Ina. 4268 Westroods Drive West Palm Beach, FL 33407 F.B.C. Non Nigh Velocity Hurricane Zone) 02003 EAsTaN METAL SUPPLY, INC. BERTHA HV TM Accordion Shutter System �• N 0ESC61Pa0X OATC Tc•n : ]A.S. DRAWING No 05-196 VARIES 12" MIN. 1/4• 0-20 SS. LA 3/6•,-I6 1 130' (SEE DETNIIS�CREWS.ACETAL *1 µ {Y • N a [ Iwo 67 Q 37 (SEE'N01ES-UN-SHEkT-4J 3/8"0-16 ACERL THUtd-- CR_EWS 1 4" 0-20 S.S. 5 5� 'n ; 2D FADED DIE CAST 1 4'-� (2 ITp.) ,a HHaus C aW:E1 DIE CAST PNNIEp HW9ND EMANEL R, eARm PAORED MTOR .e75' m A / KKDe. I RASS CTIINDER 61L11•. CMNmw ' PLATED) .(LHflWE (CFOIONE PLATED) (SEE NOTES SHON 4J�--+ .O 1 PLASTIC HEAD NOLDEO TO scREw g• n q - . 1e•N60• AFTER RWEIING BEFORE RNEDNG ,S.S. TH AIB R 0 A4Lt>:&NATE •L co K iT0 H : (nrK (y�] �---�—(SEE flOTES GN SFIEET�) , *:SERIES 9444 ALUMINUM (2024_T3 ALLOY) LARGE FLANGE THIN SHEET NUTSERT, PART M Oa20, AS MANUFACTURED BY AVOEL CHERRY TE%TORN PARSIPPENY, NEW JERSEY 07034 OR •EQUAL WHEEL0ATWXER CESSED ASSEMBLYYLON BUSHING. AT EVERY OTHER ! j KNUCKLES14z2 3/4' H.V. ACCORDION PIN I W/ #fi HEAD .IIj a 92 SHORo u N NYLONRECESSE114-2.3/4' H.V. BUSHING.a s ACCORDION PIN NE W/ IS HEAD N 4� 19 13 NYLON NV E I HV •_L�—(/ HAT WASHER PIN ACCORDION I I ACCORDION PIN 9 5 315 9 0•870z3/1 fi` 0.1aa*oRIES AISI THICK X.61 302 SERIES S.S. i RIVETS EEL AISI 302 47�- WHEEL i SERIESEL I r CARRIAGE AQ I m I I RECESS D BLADE NYLON BUSHING ACCORDION ACCORDION PIN PIN Ull Ne E::: I L I; OSLADE N NYLON BUSHING. c"^� I AI LONG 1 I RECESSED IXPICAL SHUYI ER ASS' ( NYLON BUSHING --SCALED 90.324' 914.2 3/4' V.- . ACCORDION pIN f 14x2 3/4' H.V.• PIN W/ 88 HEAD I I ACCORDION 0e HEAD 8) TILLIT TESTING d: ENGINEERING COMPANY • � E7SS H.M. SOIL St- SU- 303. NRQX y Ph... : (305]971-1530 . Fa :, (]0 7 �1 5(1� •^cD; Nlecotp E9-0006719 WALTEA A TUff J. P. E P,E. SEAL%SIGNATURE/DATE FLORIDA Uc 1 44167 S S A. .American, Shutter Systems Aaaaalatian, Inc. 4268 Westroads Drive West Pulm Beach, FL 33407 N c io I\ J #1 LONG F.8•C.(Non High Velocity Hurricane Zone) 02003 EASTERN METAL SUPPLY, INC. BERTHA HV TM Accordion Shutter System EV. N DESCRIPRDN LIATE 13 6 , JAi 1 °10' T/11Am DATE: 7/13/Os 3 DRAWING No 05-196 1_:►: of � 1 jLIJ0 r 1.mamowmu ELEVATION. HV LOCK ' ONE HV LOCK QW SHALL BE USED FOR ANY SPAN AND INSTALLATIONS AT ANY ® MAY BE FLAT AS AN INSIDE OR OUTSIDE LOCK, ATTACHED TO Q OR ® CENTERMATES SHUTTER 1/ELE-ZO x 1/2" LONG FLAT HEAD S.S. M.S. LOCATION OF LOCK SHALL BE AS INDICATED ON TYPICAL SHUTTER ELEVATION. 2.on HV LOCKS 'IF DESIRED, FOR BETTER PERFORMANCE OR FOR SECURITY PURPOSES, UP TO TWO AS MAY BE USED AS AN INSIDE OR OUTSIDE LOCK. CONNECTION OF LOCKS TO CENTERMATES Q OR SHALOCATION ETIONOF LOCKS TSHALL BE AS INDICA ED ON TYPICAL SHUTTER ELEVATION. 3. LOCKING RODS (ARE NOT REQUIRED AT HURRICANE POSITION, BUT MAY BE USED IF DECIDED TO ENHANCE SHUTTER PERFORMANCE. LOCKING RODS Q OR AN ALTERNATIVE DEVICE MAY ALSO BE USED AT STACKING POSITION (NON HURRICANE POSITION). 4. 61Adp�1TORY cOkeMT S2 ONE HV LOCK ® SHALL BE USED AT CORNER CENTERMATES FOR ANY SPAN APIp INSTALLATIONS AT ANY ELEVATION. HV LOCK CORNER CENTERMATE W/(2) 1/4"0_20 x 1 2'S ONG BFLAT HEAD ASS. AN OUTSIDE -TWO OLOCK NGERODS Q AT TOPOdc 0 BOTTOM SHALL BE USED. LOCATION OF LOCK SHALL '-BE S INDICATED ON TYPICAL SHUTTER ELEVATION. MAXIMUM SHUTTER SPAN SHALL BAS DETERMINED PER SCHEDULES SHOWN ON SHEET 9. 5. ALTERNATE LOCKrTELOCK BE. ELEVATION. ALTERONE WISMAY BEl USED S ANHV INSIDE SIDEFOR OUTS SPAN DE LOCK. ATTACHMENT INSTALLATIONSATANY ALUM. RVNUT As SHOWN ON ALTERNATE SECTO 0 OR TINENTERMATES 12, SHEET SHALL BE MADE W/ 1/4"0"20x3 4" / k N �eRO a O0fl iOOq®�O ¢I �Yy.qy INe. i ` `• • - .. ; y_' TILUT TESTING 1: ENGINEERING COMPANY a7s7 1LN. JeVi. se. see. 300. IARONA URGEN9 FLARMA ]91e5 Phone: (70 )1171-1930 . Faa —maB: 47hcomocl.cam /`• " P.E. SEAL' SIGNATURE/DATE E9-0006719 TM A lie. / ,p. P. E W��N A c. 1 441137 �MCH_1_ �_ _ 1► AwS.S.A. American Shutter Sya tome Association, Inc. 4268 WeStroads Drive West Palm Beach, FL 33407 ©_0 OF CORNER CENTERNATE F.B.C.(Non High Velocity Hurricane 02003 EASTERN METAL SUPPLY, INC. BERTHA HV u Accordion Shutter System i. 13E9CNIPIION GATE Omvn .9MOWh 7/13/OS DRAWNG No 05-196 'D 961-990 ON ONIMVH(3 c a0/f l/L 31Ya WWI rro-ro cm L '$YI : 0 u�e�p uyp NOLLdN]530 I N '!3 MIS4S aaun% uoipaooc)V m AH Main 'ONI 'Pddn5 1d13W Nb315b3 CODZ� (auez aUD3ll-nn "'!""A 46iH UON •O'e- 4 (II M— NO 31n03H05 +V S310N 33S) 33N61SIO 3D03 - -0 -3 03NIaN ] 3a�NVO SN01133S ONdN ON ZI A18N3SSY H311nH5 1VOIdU 80.1 C 133HS 33S -1 i LOb££ ld 'yDOeg Wlpd Asa LGI» 1 5n r0lnpv 3 'd W IMLL v u3nrH, 31V 0nup SpDOJISOM 29 M '.'1ul 'u01I01002Sy worioopoii N 03� ICGI-ILS(GO[) : j • O[GI-ILS(GO[) �uoyj oBl[C VOMDV 'SH30N1] 'C][ �' 1 suaopft Jo}}nyS uCIDllaWd gHl]tlN 'h5 95 'W9[ 'IM1N GG[0 1.NYdWOO ONIU33NION3 V ONIIS31 bill ■d 3 'l l n nS/lV3S '3'd S1Id130 N011dl ISNI Rm"wmwj Tn ® SinN OL-.1/1 ONISn NO 31n03H 513335) 03HIIID38 TVM S EIOS 3NIHOVN a,3ry SSnNl MDOI3 RG)JONO3 y0 So'fnlHd 'S'S .f/CrOZ-0,y/l .I SNOHONV 313y311 �313"O"OD 03NnOd C M WIN L-�� i D rno . b (OI 133HS NO 31n03H3S 33S) S80N3Ny 313NONO3 'dj5 -NIN 03NInO3" 313N3NO3 - 038nDd CONCRETE ANCHORS (SEE SCHEDULE ON SHEET 11) EDGE OF SLAB IF APPUCIIBIE ,r B ORn IF F 3LE LFLAT HEAD CONCRETE ANCHORS (SEE SCHEDULE ON SHEET 11) © �'LIC—OV�_MOUNTING INSTeI I er10N /140/4' S.S. HEX HEAD TEN i SCREWS a S' D.C. OR 1/4'0_20 --4 S.S. M.S. W/ NUr a S- D.C. HER HFAO D.C. i 1 SHEET 11) i i EDGE OF STAB IF T 1 PPUCA13E THIS INSTALLATION SHALL BE ORNTRAN O AN OPERABIEEEXIT OR ENTRANCE Iz NOTE FOR CONRINATION tL SECTlOrj : I- SEE SHEET 3 FOR TYPICAL SHARER ASSEMBLY , - MWNTING SECTIONS CAN BE COMBINED IN N4Y WAY TO SUIT ANY WSrALLATI0N. • I- D. = EDGE DISTANCE (SEE NOTES 4 SCHEDULE ON SHEET 11) CONCRETE ANCHORS (SEE SCHEDULE ON SHEET 11) EOCE OF SLAB IF APPLICABLE E�QOR MOUNTING INSTA I eTIAR ## POURED CONCRETE REQUIRED E D r. QQ FLOOR MOUNTING_ INCTAI I AT10u ,I, INSTALLATION DETAILS • TIN T TESTING k ENGINEERING COMPANY 3]39 N.W 331h SL, "- 30q ..;� ••.1 �••+d_=I V1RQ-K rARM., RAW.A 331, P"-1 : (303)W1-1830 . Fa : (3091e71-193I -maW ••� 4 P.E. SEAL/$I RE DATE NGmmaol.com EB-0003T1B WALTER A. TILLIT Jr. • a. E FLORIDA ua ( 44197 A.SuS.A. American Shutter Syatama Aaagolation, Ina, 4268 Westroods Drive West POIm Beach, FL 33407 B.C. Hon High Velocity Hurricane © 2003 EASTERN METAL SUPPLY. INC. BERTHA HVTM Accordion Shutter Sy EV. N DESCRIPRON 1 p3 w-w. fYUIm neTC'. DRAWING No 05-196 OUT I (6053-1 .6 ALLOY) ALUM, ANGLE W/(2) 1/ay TAPCON ANCHORS 70 CONCRETE I (TGP/e0TT0O) h (4010.1/2' S.M.S. TO TU6E AT EACH ANGLE. I Inp)1 ^ I /—EXISTING GLASS * SEE NOTES ON !!/ LOCKING// RODS ANO ALTERNATE LACK ] ©• aN SKEETFIV LOCKS FOOR O , i10R 1/2' �. piax3/4• S.u.S. 0 12• O.C. FULLLENGHT. `"ISGLASG ,•N,IN SEPARATIwON OPTIONAL* W TO GLASS (INTERIOR) L_ 4. -------------------------�EXlsnnccAss SE ENO WA ONN T DETAI ON aul:rrc o .. 31/4•— — — — — — — — — — — — — —� 7- 6 1/2• OPPOSING ,. CE TER ATES SYMM TRICAL LDc . CENTE�ES W * * W Lp * 1' MIN. SEPARATION I N U 7 TO I GLASS © OR OUT X *U SECTION 12 AT CORNER rl: 'TE"• t 3 _ EMI����� � 10-7 °RO SECTION 12 OUT W — EXISTING GLASS SYMMETRIC; — — C NT S GPnONaIO*� IN ��-,(�)ORZOR r — — — — — LOC ) ((( 1• MIN. --/ (INTERIOR) 00R0-H@GR0 TGACLA55 ALTERNATE SECTION 12 HORS Ie• O.C. 19 OR O `w 0 UT a 1/2' MAX. SLACK SECTION 12 AT SI erlt T DE MAIL PLICA9LE1 F.B.C.(Non High Velocity Hurricane Zone) Zl� ©2a03 E/6SfERN METAL SUPPLY. INC. BERTHA HVTM { TILLIT TESTING &ENGINEERING COMPANY ~'�'�■�■ Amerlaan ShYffer Syafema Accordion Shutter System rr .a c — 34UL SL, 54. 7a7. WRONN aMOEIQ. ROWOA J]lf9 PNana (305)971-IS]0 . F.. ; (3aS)971_1531 =-mun: UR.ccaua.ccm Amcclaflon. Inc. 42B8 Westroads a,. N OCSCRIPOON 0A7E Grown 1 0 °' °'• '/+/a+ PATE: 7/la/05 - P.E. SEAL%SfGNATZ;DATE Ee-GDae71s WAUEN A. TIWT Jr. P. E DTfve West PGIm Beach, fL 33407 2 3 DRAWING No FLaR;oa u�. f 44167 • 05--196 POURED CONCRETE OR CONCRETE BLOCK WALL REQUIRED POURED CONCRETE CONCRETE POURED CONCRETE CONCRETE ANCHOR -� ® 16' O.C. EXISTING CLASS BLOCK BLOCK WALL REQUIRED /--IXISTING GLASS OR CONCRETE BLOCK WALL REQUIRED CURED CONCRETE OR CONCRETE BLOCK WALL REQUIRED 1 L _ GLASS 2' MIN � — -S T WN EXISTING E0 i E0 MIN.— SEPARATION 1" —�IXISTING 2` GLASS (LOCATE AT TO CLASS 1/16'x3' MAX. (6063-T6) CONr. ALUM. CLOSER SEPARATION - I, MIN. l T ETTH SIDE PLATE. (LOCATE AT EITHER E SEPARATION ' l OF ) SIDE OF NO) 1MIN _ \ / , GLASS ' 1' MN. SEPARATION 1/T' MIN. _ I 1/2- TO C1A55 - YIDYI/T' I 1 I ♦USE LI OR 2' I 1/6'xO'-2' APPINUMCCLIP ® I6' O.0 'S.M.S..O.0 e 16' o,C _ _ _ _ AL(As ALUMINUM CLIP ANCLE ANGLE "�--- - (BO63-T6 ALLOY) AT NIOHEIGHT -_--_ W/(1)#IOxt/2' S.M.S. TO©& (2)1/4'0 TAPCONS ANCHORS To WALL AT 1' C.C. SEE DETAIL X FOR SEE DETAIL X FO (LOCATE AT EITHER SIDE OF N& SIDE CONNECTION SIOE CONNECTION TO TRACKS OR©Oq®Oq TO TRACKS SEE Ofl®+QORO 0R®OR®OR® DETAIL % FO OR©oR®OR® SIDE CONNECTION TO TRACKS URp Ofl®OR� AND CONNECTION DETAIL ----' � AND DR+4l ORO DR®+�°R� ® OR®+OORQ CONNErr(nu p Te11 O �, =END CONK rr�na nETnIL ��� POURED CONCRETE OR ' — AND CONNECTION DETAI , CONCRETE BLOCK WALL REQUIRE POURED CONCRETE OR • REOUIflEO ONLY FOR SPANS GREATER MAN _ _ —T _ EOUIREO R r � — — — — — EXISTING • 1 rCLLS I' MIN. 01Ox1/2" sASS .M.s. I SEPARAT S 0 12' ax 1' MIN. TO CL/ SEPARATION CONCRETE 1/2" MIN. To GLASS CONCRETEANCHOR ANCHOR a 12' O,C. O.C. 1/2' MIN. •_Ej7D —I--.1 HV 3F 2- END CONN [`Tlnu neTAll `UQRUC OR(E)OR(E) ' O OR®+OoRO. AND CONNFrrTnT,T Ill"TAu OR®+OORQ °R®+(DORO VIEW Y PLAN r'c —ki F.B.C.,(Non High Velocity Hurricane Zone) u.v - ®2O0J EASTERN METAL SUPPLY, INC. IL ASS■S A BERTHA HVTM ■ ■ Accordion Shutter System TILLIT TESTING & ENGINEERING COMPANY American Shutter S Ote�Tte xO79 N.W. O5"' St" St' OOS, MRMNA GMDMS, 1-MA MIN � EV. N Qr.SCR1ARON DATE D_A i JAS. ! ] = Ph— : L3O3)071-IZ3o . Fax t (3as)e71-lnal AmOC(at(on, Inc. '• FG _ 4268 Westroads Driva T DATE: 7/13/O: •1Q a -mail: UIt�cGOGGI.wm 2 Es-GDoml9 West PQIm Beach, FL 33407 J DRAMNG No r� _= WALTER A 71LUT Jr. P. E. D5-i 96 P.E. SEAl �6URE�DATE FLORIDA Ue. Y 4a1e7 4 i MAXIMUM SHUTTER SPAN "L+" OR "L—" (ft.) INSTALLATIONS WI �(METRICA IT R JArrc ONE HV LOCK & NO LOCKING, ROCS (SEE NOTE t) Ctr29ETE d: W000 INSTALLATIONS 6 Ll WALL NOUNTINC FLO (V'.1.) OR/CDUNG (+ _1 MOUNTING MAXIMUM SHUTTER SPAN "L+" OR 1—" (ft.) INSTALLATIONS W/ OPPOSING rFNTr:T3uA•r .- ONE HV LOCK & NO LOCKING RODS (SEE NOTE t) CONCRETE do WOOD pE I INSTAIJATIONS 4uJ•) WALL MGUNTNG FLOOR/, MIN. MOUNTING INSTALLATION I p�� CONCRETE & MANSORY WOOD WALL MOUNTING 1, 2, 3 & 4 1W, 2W. 3W, 4W. 5W & 6W FLOOR/CEILING MOUNTING 5,6. 7 aw, 9W & & low ♦ MAXIMUM SHUTTER 5PAN 'L+' OR 'L—' FOR INSTALLATIONS INTO WOOD SHALL BE UNITED To 110 POT. DESIGN LOAD. F R CENTERMATE g3MAY BE USED AT ALL G INSTALLATIONS. LOCKING SPECIFICATIONS E AS INDICATED ON MANDATORY CONDITION g2 SHEET a OF to Y ••'' j7 TILUT TESTING & ENGINEERING COMPANY 4TSS n.W. ]SIN. SL. St.. 30. yylGryN GWOM FLOWOA 33160 Phan. (30S]871-18]0 , F..: 309 )871-1531 '�` P.E. SEAL°. ` �i ~~ S�FIDATE VIAL•` FE-0009719 FLORIDA u .. / 44167E NOTES . (1) L+: MAXIMUM ALLOWABLE SPAN FOR A GIVEN POSITIVE DESIGN LOAD. L—: MAX. ALLOWABLE SPAN FOR A GIVEN NEGATIVE DESIGN LOAD. (2) PROCEDURE TO DETERMINE MAXIMUM SPAN FOR WALL MOUNTINGS (TOP/BOTTOM) OR FLOpa/CEILING: GIVEN A POSITIVE DESIGN LOAD, DETERMINE MAXIMUM SPAN 'L+' FROM SCHEDULE GIVEN A NEGATIVE DESIGN LOAD, DETERMINE MAXIMUM SPAN 'L—" FROM SCHEDULE FINAL hWOMUM ALLOWABLE SPAN IS EQUAL TO THE MINIMUM DETERMINED SPAN BETWEEN 'L+' AND -L (3) PROCEDURE TO DETERMINE MAXIMUM SPAN FOR COMBINATIONS IN BETWEEN WALL MOUNTINGS W/ FLOOR/CEILING MOUNTINGS: FOR A GIVEN POSITIVE DESIGN LOAD: DETERMINE: . _ LI+- MAX. SPAN FOR WALL MOUNTING INSTALLATIONS. L"- MAX' SPAN FOR FLOOR/CEILING MOUNTING INSTALLATIONS. FOR A GIVEN NEGATIVE OESIGN LOAD: DETERMINE: L1 MAX. SPAN FOR WALL MOUNTING INSTALLATIONS. L3-- MAX. SPAN FOR FLOOR/CEILING MOUNTING INSTALLATIONS. FINAL MAXIMUM ALLOWABLE SPAN IS EQUAL TO THE. MINIMUM BETWEEN 'L1+, 'LZ+', -L,--AND 'L2_. (4) GO TO ANCHOR SCHEDULE WTH FINAL MAXIMUM ALLOWABLE SPAN AND NEGATIVE DESIGN LOAD TO DETERMINE MAXIMUM ANCHOR SPACING. A.S.S.A, American Shutter System® Aeaoclation, Inc. 4268 Westroads Drive West Palm Beach, FL 33407 F.B.C. Non Nigh Velocity Hurricane Zone) 0 2003 EASTERN METAL SUPPLY, INC. BERTHA HV TM Accordion Shutter System �• K OE3Cf0PTi0N GATE 0n JAS. 1 we m-m. 7AJ DATE: 7/13/05 ] DRAWING Na• 05-196 0 ANCNaps m wlNa 4TFNa TAPCW ALL PD8a8 SDL)D-SET WEbOE-80I,T 21. 2" .r�.IM.9.uEavvvom®�Eivm®mom®©va 0®ux"Im m®i®EMENIM m®�ovvoommi®E�vvooz 0 ulaugg ®0®KNIMIN �®mr�0[�Op ®mOr,©Op mr®move®om,®mravov®m®�vvonom®Qavrao�om mt®Ialwin ®m,®mvvuvom®mraovvom®more©vv� ra®mono®vIM®EMMIM ®�al�®mivviuv©rv®m�raovosaIM ®m10�0©®�®m0000�i m®�00000®mQ®©00Im m ®m,®moo®ovmt®mEav®vvQi®mioiunivomt®vvvovom ®m1000Q� m1®m00�0 mt m®�000�©m1®m�0�00 m ®®m100�00 mt®��0000 mf ®�00000 In ®®�OD000 m m1®01�©©00 mt®m00®Q� mf�000®0 ®®000000 m mt®�av®vvo m�®monies oio m®mlvvor�es, m®�Ea�oav m ®®OEan©oo�®�onrovv 0®mor�nnoml®m©©vov® m�lE�m®®voo m®mol�volo m�mvo rneav ®em©OOIOOO �E mn®vo m®moouo�iommi®®®o�ivvo�im m®u®©�ololln®mo®vomm®mvvololy®v©olrvvetolm ®mom®vov�®mvvvvom®m�nvvom®©vvvvom ®®u��aoieavml®Imirivvvom®�orvvvv®�oiravvoravlrm aa®vomvvea�®�v�a�aoioi0®mraEaealvv�am®©®oivve�m ® ®®rnvololvolaa®mvvvvom®mivvv�e�m,®®oioie■ovm ml®vv>vvoea0mm�vvvaim�vvvolom®volvvaeam m®meov�aomt®mae■et.oeam®0�a�avveamt®veo®omlm mt®vovve�omi®mie�vovo mt®moo�avom®©ve�ere�oim m®Ov0v0�i m®®0000�7 mt®Ir�00vOC�00®OptOt00 ®®�v�v�ava�®ovvv�ar■m®meavvoaa®®avvveroim m1®®00000m1®000000m®0000v0m000®000m Im mom®vvvvoiv�am®ravv�alvo�®�avvvvv� ®vvvvo m®i®mv�ovom®mvvomi�v�vvvo�ivo m [ifG�iOOCfOpp m®OvppOp�®0000v00tED iJC�00000 [l OQOOOOOOV IO®Ovii0000®OOOOOO ®Qm100L7�iC�L'i0 m aa®Ivvvvvva�®vvvveavmtvv�avva�©vvvv�ae�go m OOOOOOfO mv000000 �0000000 ®671000pv0 �vvvoivvorvotvvoi�oraiuvveavAtas rnvvvolvvall aimean■vovvva��a�avvoivommi®v1110 vm 0v0100sem w` i'• _ TILLIT TESTING &ENGINEERING COMPANY 3D3. NRGINIA GARDENS. flARMA ]]lao F.x : (303)1171-I531 ' SEL/5 W�T�""JJP.E. ' P.JDA l. 4416 * SEE ANCHOR SPECIFICATIONS ON SHEET 11 WALL MOUNTING 4 ®m0000� NA 00000 ®m�10000� m®m0000� ®m10�®Ot0 m®m00000 ®®m000t�0 ®m�onv©om®mvoraoMl ®m00000mt®�Ex ®00®tQ�tQ M mt®000®� Q ®Inor�®eaom®monr�®o mt®�0000 ®100®oiollv0®®o©vvv ®aavv©vv0r®�vor�vv ®Q70peiL7p ��©ovvol®mo®vealvv mmm00EaEi0 ®mv®vololrummlonmooi ®mpl©eloe� ��©vvvv®rov®©eaoot a�mmvvoloo ®aaniraoivom®�v®Diva ® u®�a�arouav ®m[llmOmO ®m©oe■o�amimmv0000 m�®®vvoly ®m®eavo�aml®m�vvov ®volvvvaa®©olv�aoo ®miv�araova�®rnvvoery 13Ea00000m1m0®Cf00C7 vololvvotra �riesOl0e�01 �vo�voe�®v m®m00�av10 �vveatvvv��®eaoivoly �r�o�oovea0mvont0�av �®v�avoly r�orvvvv®e�lrvv®vvov a>,mf�v�oi�aoi �vvovvv®®vvolorvly ®o�vvvoiv mtmvv�avv�a via®vv�avraoin M vvoiv�aomtvvvvvvv wil �v�avvoty mrvlorvorvvv A•S.S■A■ BERTHA HV TM AMeflcan Shutter Syatarrta Accordion Shutter System Association, Inc. REV. N DESCNPTIGN DATE Drvlrn JA.S, 4268 Westroads Drive 1 s an m-m. 7,1a„� DATE: 7/13/05 West PQIM Beach. FL 33407 ] DRAWING No 4 05-196.. ANCHORSRPACING 1 Fl1A,R1 T_CON ALL POINTS SOL10-SET WEDGE -BOLT NA WAIN CEILING MOUNTING 5 SPµ (It) IEGAi1VE Oma I Dan r, 3'-0- 4,-0' m®13 Q almmOtl7pppa tple,•eaa OmKOKO 0mMEN Ova Ron as1mF>I00®El El In ON El ' a>lmvolvmlvo¢ Qi®tlnovmooa alI07®0©OIOtOa' In In ® ON atamMEN mmt�®®OOQI 101v� ' m®03in 0©00101� ®��Iv©0000� ME will ' �m' 0® ®Om M EnD0000Elm ®IRMO srrn FLOOR MOUNTING 6 I>rYY111ra7 �7i, Ot1,Ot1310a Ot0000 a Ell a von00� I7Eit00p IC 00131 0011M vOtt700� 00Im vtt7p00� vOtt70001 �QOOtO EX Ell0 in000�0 m 0000�0 Is 000017a] F�010v0m �0000 v010001 al �0000 �OIn =III �01ON 01111 ===== IE i01=01Om w==stsM P.E. ono"INIC ®0©®ME INEDIUMM 1000000 000MEOM i 0I0©000 i00®®00 0©000Q QI0®®00 113MUM00 :"®t9Ot00 :H©D000 A®DOOC ©0®000 vtH00=0 111t7IDOp0 t�000v0 �m0000 main == 2300000 ©vv01=1 231 101100110 ©00000 v00ose FLOOR MOUNTING 6 e .acaia�` lig w 001E1010 M®t000 ronnEla t>D®®00 170p100 11®t000 """ME ZItU®00 tn0©00 �01M00 KNEUMMM I0000 0®01010 ar�01010 W EBON00 131v00C XIo0ta110 Ll010 81 v000C v00100 v0v00 v001010 Ii0000 v0101010 �v00e i ) TILLIT TESTING & ENGINEERING COMPANY 0757 NW, 301R SL. Ste 705. VIRGINIA OAAOENS. FLORIDA 371 Ph—: (3OS7B71-15]a - , Fox t (3a5)B71-1531 .-mcD: U7l.caoaal.com ®-aoaeTla . WALTER A. TLLM jr. P. E 'DATF FLORIDA U. f 44167 !NOTES ON ANCHOR REQUIREMENTS- POURED ONCHErEOR CON r SUBSTRAT;'q 1. ANCHORS To WALL SHALL BE AS FOLLOWS: (A) TO EXISTING POURED CONCRETE (MIn. rc - 3 YGI) I/4'F TAPCON ANCHORS, AS MANUFACTURED BY I.T.W. RAMSET/ RED HEAD. 1/4'0 a 3/4' ALL POINTS SOUO-SET ANCHORS AS DISTRIBUTED BY ALL POINTS SCREW, BOLT k SPECIALTY COMPANY. - 1/4'0 WEDGE -BOLT ANCHORS AS MANUFACTURED BY POWERS FASTc10NG. INC. NOTES: A,0 MINIMUM EMBEDMENT INTO POURED CONCRETE OF TAPCON ANCHORS IS ANCHO13/a•, AND 2' FOR WEDGE -BOLT RS. A2) MINIMUM EMBEDMENT OF I/4'A ■ 3/4- ALL POINTS SOUO-SET ANCHORS SINLL BE 7/B' INTO THE POURED CONCRETE. NO EMBEDMENT INTO smcca SHALL BE PERMRTEO. 1/4' P-20 S.S. NACLL SCREW USED SHALL R 1 1/2' LONG MINIMUM SHOULD STUCCO DUST, µD 1• MINIMUM FOR WALLS 5- NO STUCCO, FlA]) IN CASE WT PRECAST STONE, PRECAST CONCRETE PANELS, PAVERS OR ANY VENEER BE FOUND ON rAE NISMES. ANCHORAGE SHALL BEORS AS INNDI�CATEOBE-LONG NOTESO AI) k AR�FBOVE THE F R 1h5TALLA710N3 STRUCTURE ON VISAONYL STp C OR EFS CONSULT THIS ENGINEER. (0) TO EXISTING CONCRETE BLOCK WALL: - WIG TAPCON ANCHORS, AS WNUFACTUREO BY I.T.W. RAM5LT/ RED HEAD. 1/4'A ■ 3/4' ALL POINTS SOLO -SET ANCHORS AS DISTRIBUTED BY ALL POINTS SCREW, BOLT 8: SpECUL1Y COMPANY. - I/4•F WEDGE -BOLT W/ 1/4'/ BLOCK -PLUG ANCHORS AS MANUFACTURED BY POWERS FASTENING, INC. NOTES: 8.1) MINIMUM EMBEDMENT INTO CONCRETE BLOCK OF TAPCaN @ WEDGE -BOLT ANCHORS, LS 1 1/4' 0.2) MINIMUM EMBEDMENT OF 1/4'A ■ 3/4' ALL POURS SOU0_SEr ANCHORS SHALL Be ENTIRELY EMBEDDED INTO THE CONCRETE BLOCK. ND EMSEOUENT INTO STUCCO SHALL BE PETRMITIEO. 1/A G-2O S.S. MALi11nE SCREW USED SHALL BE 1 1/2- LONG MINIMUM SHOULD STUCCO E70ST, AND I- MINNdUM FOR WALLS S.SWIT. A STUCCO. 0.3) IN CASE THAT PRECAST STONE PRECAST CONCRETE PAMETS, PAYERS OR ANY VENEER BE FOUND ON THE EXISTING WALL OR FLOOR. ANCHORS SHALL -BE LONC ENOUGH TO REACH THE MNN.STRUCRIRE SO4M UO WALL FISHES. ANCHORAGE SHALL BE AS INDICATED ON NOTES 8.1) k 9.2) ABOVE FOR INSTALLATIONS ON VINYL SUING OR EIFS CONSULT THIS ENGINEER, (C) ANCHORS SHALL BE INSTALLED FOLLOWING ALL OF THE RECOMMENDATIONS AND SPECIFICATIONS OF THE ANCHOR'S MANUFACTURER. (0) SEE SCHEDULE BELOW FOR EDGE DISTANCE (E0.) VERSUS SPACING RELATIONSHIP FOR ANCHORS. EDGF DISTAN('F An'RSuc CpA Ih FOR AP rHORS uNBUUN ANCHOR SPACINGS ARE VAUOT FOR 3 1/2' EDGE DISTANCE FOR 1/4'. TAPCON AND SOLD SET AND WEDGE -BOLT FOR E. 0. LESS TW4 THE ABOVE MENTIONED, REDUCE ANCHOR SPACING BY MULTIPLYING SPACING SHOWN ON SCHEDULE BY THE FOLLOWING FACTORS. (NOTE ; Mln. E D. FOR ALL POINT SCUD SET ANCHORS IB 31 REDUCED SPACING OBTAINED USING FACTOR SHALL NOT BE LESS THAN MINIMUM SPACING INDICATED FOR EACH ANCHOR TYPE, FACTOR ACTUAL E. U. WEDGE -BOLT 1/4'A TAPCON SOLO SET KK SPACING - 34 Naf: WAaNG - r LItL SPACGW . 7 ]' 0.43 GA3 0.78 2 1/2' 0.55 0.86 - 2' OSD 0.50 A.S.S.A. American Shutter Systems Association, Inc. 426EI Westraads Drive West Palm Beach, FL 33407 F.B.C.(Non High Velocity Hurricane ® 2003 EASTERN MEAL SUPPLY, INC. BERTHA HVTM Accordion Shutter Sy • H DrscRwnaN DATE D,,,,n 1 ry m-oL .r......1 nA•rv. DRAWING No. 4 05-195 SHEET :E� U B �TF�ATE SOUTHERN PINE No. 2 W/ MIN. G=0.55, DOUGLAS SPRUCE" PINE FIR NORTH SPRUCE PINE FIR SOUTH IeaxlMUN FIR W/ MIN, G=O.50 SPAN (R) WALL MOUNTINGS CEILING MOUNT 8W w/ MIN. G=0.43 WALL MOUNTINGS w/ MIN. G=0.36 1W, 2W, 3W & 6W FLOOR MOUNTINGS )yy 2W 3W & 6W CEILING MOUNT 8W WALL MOUNTINGS 9W & 10W FLOOR MOUNTINGS CEILING MOUNT 8W 9W & LOW 1W, 2W, 3W & 6W FLOOR MOUNTINGS NEGATIVE DE91GN LOAD (P.n .NEGATIVE DESIGN LOAD 9W & low , (PG9 'NEGATIVE DESIGN LOAD (P4Q R'WATIVE DESIGN LOAD (Psf) NEGATIVE DESIGN LOAD (Psi NEGATIVE DESIGN LOAD (pef) 30 40 60 75 90 OS 30 40 60 75 90 105 30 4o Rn 7S e OR I rcc f 0 4 n .. .. _ ..� . _ 'F NOTES ON ANC IOR�REOUIRFA�FNTc u:nn 1. ANCHORS TO WALL, FLOOR OR SOLID WOOD SOFFITS v HALL BE AS FOLLOWS, ' - I/4 TION ON SHEETS OH ANCHORS EACH SECTION ,I] ASrE MAN14.UFACTURED BY I.T.W. BUILDEX W/ NIMMUN EMSEOMENT AS INDICATED AT EXCEPTION: SEE NOTE 2 BELOW. - 2. ANCHORS TO HOLLOW CEILING SHALL RE AS PER MOON INC TYPE 7W, SHEET 14 AND yT� CONSIST Of LAO SCREWS AS PER NOS 1997 SPECIFICATIONS, 3. SUBSTRATE SHALL CONSIST OF THE FOLLOWING: SOUTHERN PINE No, 2 W/ G-0,55 (N.D.S) -OOUGLAS FIR W/ 0-0,50 (N:D.S.) -SPRUCE FINE FIR NORTH W/ 0-0.43 (ND,S.) -SPRUCE PINE FIR SOUTH W/ G-0.35 (N.0-S.) -EIW. f/2- CDI( PLYWOOD (1906 APA) 4, ANGHOn SHALL BE INSTALLED FOU,OWWG ALL OF THE RECOMMENDATIONS AN SPECIFICATIONS OF THE ANCHOR'S WNUFAcIuRER, • • TINT TESTING & ENGINEERING COMPANY ,(- �. • ,� tom- 5353 N.N. 3dtt. 5t1 3t4 305. VAGINV, OAROENS, "MMA 33155 Peen (30S)571-IS]O . F4a : (]09)571-15]I a -mail: WhenOaal.cam WALTER� 7ILUr 41. P. L P.E/DATE TLO9IDA UG, t 44157 A.S.S.A. American Shuffer Syaterna Aaacclatlan, Inc. 4268 Westraads Drive West PGIT Beach, FL 33407 1/2" MIN. COX PLYWOOD WALL MOUNTINGS 4W & 5W NEGATIVE DESIGN LOAD (par) D F. C.(Non High Velocity Hurricane Zone) 0 2003 EASTERN METAL SUPPLY, INC. BERTHA HV TM Accordion Shutter System Ev. N. DESCRIPTION GATE D.a." .4As. 1 m ar-mA T/iT/4a DATE. 7/13/05 3 DRAWING No 4 05-196' WALL FINISH — 1/4'01 TAPCON W/ 1 1/2' Mln. PENETRATION OF THREADED AREA TO EXISTING WOOD HEADER. (SEE SCHEDULE ON SHEET 12) I F OR irrr, a EXISTING MIR. 2%4' WOOD AOER REQUIRED 1' MIN. PARATI 0 GLASS =�=Nffil 0 2 iE�..ISDNG MIN. 2 aa' WOOD . HEADER REQUIRED 9 1' MIN. 1/4"0 TAPCON W/ 1 1/2' Ni, PENETRATION OF THREADED AREA TO EXISTING WOOD HEADER. (SEE SCHEDULE ON SHEEP 12) 1/4'a-20A3/4' S.S. MACHINE SCREWS W/ 1/4'-2a NUTS 1^ Mln. D UQIF. 1—SEE SHEEP 3 FOR TYPICAL SHUTTER ASSEMBLY 2—MOUNTING SECTIONS CAN BE COMBINED W ANY WAY TO SUIT ANY INSTALLATION, V C10R© N 11 EXISTING • GLASS--J i 1/4'0 TAPCON W/ 1 1/2' Mtn PENETRATION OF THREADED AREA TO EXISTING WOOD PLATE . (SEE SCHEDULE ON SHEET 12) Z'a4' CONT. SILL 3W WALL CONNErrinu PLATE REQ'0. . Ar BOTTOM ( 1' MIN. EPPRATIO! I TO CUSS I I WIN 1 2'a4^ cDNr, E t a WOOD PLATE E $ F OR © REO'0. EQ Z I/4'0 TAPCON W/ 1/2' Min. PENETRATION Min. — G G OF THREADED AREA INTO PLYWOOD. 1/4^m-20x]/4''S.S. MACHINE (SEE SCHEDULE ON SHEET 12) SCREWS W/ 1/4'-20 NUTS 7IL/4'9 Mln,�1 /2^ MIN.COX PLYWOOD REO'0. O 12' O.C. 4'a-203/' S.S. MACHINE C�D. REWS USING 1/4'-20 NUTS IXISTING WN. 2S4' STUDS O I8' O.C. MAX. REQ'0. PLYWat)a TO BE V2' NIN. CO%—S P/F1T�jON OF THREApm ggEA, IM•p 12' O.C. ATTACHED TO STUDS IN ACCORDANCE WITH SECTION 2308 OF THE F.D.C. PLYWOOD REQ'D. PLYWOOD. N W/ 1 1/2' Mtn. PENETRATION OF k THE S.B.C. (FOR NEW AND EXISTING' CONSTRUCTION RESPECTIVELY). WALL FINISH (SEE SCHEDULE ON SHEET 12) THREADED AREA O YIOWIOTH OF Wppp PLATE (SEE SCHEDULE ON SHEET 12) ®W WALL CONNEcrw AT BOTTOM ©W WALL CONNEcrinu 6W WALL CONNECTION AT BOTTOM AT Anrrn � . Q F.-C.(Non High Velocity Hurricane Zone) ©2DB3 r•�:.�y;� � EASTERN METAL SUPPLY. INC. _. I L - EC O �„�, BERTHA- HV TM a►■ n ■S■A■ Accordion Shutter System T1LLIi TESTING do ENGINEERING COMPANY Amarlcan ShUN®r Systems EV, N ss N.W. Gem. SU, el4 30s, MRGHIA GAR001 , 111,11, 331e9 Association, Inc. BLSCRIPnpn BATE ana.n a4 Bul z: y' •A`'. .. Phony ; (3u5)071—IS30 . Fax I (303)B71-1531 1 a� oa-wa TIum DATE: 7/13/Ds •'ZQ �'_--"~ e—mail: U'14coaool.com 4268 WestroadS Drive 2 �/: +• re-OUM J West Palm Beach, FL 33407 s DRAWING No '•'"•'^K"�' . D wAl1ER A. TILUT Je. P. E P.E. Sig' %51CN7iTURE/DATE n0R10A U-• 9 44107 4 0Ej-1 96 9 6, D.0 S.MS, a O.C. I I I OPEN HOLE AT EACH MO TO ACCEPT 5/16'0 LAC SCREW AT CENTER OF TUBE. I 1' MIN. EDGE (IF APPLICABLE) BEAM fSEIqj UIRm-�STRUCWTURAL ADEQUACY OF EXISTING WOOD BEAM TO BE CERTIFIED BY EXISTING WOOD TRUSSES OR REGISTERED ENGINEER OR ARCHITECT' PRIOR TO SHUTTER RAFTER 0 24' INSTALLATION. O.C. REQUIRED EXISTING SOFFIT 0/4' Max. TKK. 1/4'0 / TAPCON W 1 1 Min: --I'x4'xI/6' COM. ALUN, TUBE (6063-TB ALLOY) W/ PENETRATION OF THREADED AREA TO EXISTING WOOD BEAM, (SEE SCHEDULE ON SHEEP 12) (])5/I6'0 RAC OSCREWS TO EACH RAFTER OR O TRUSS. LOCATE LAG SCREWS AT MIDWIDTH OF EXISTING WOOD MEMBER, (2' IRn. NOMINAL WIDTH) W/ 2' Mln, PENETRATION ) OF THREADED AREA VAUD FOR INSTALLATIONS YI of MAX, I I DESIGN LOAD AND D P -- MAX IS ONLY SPAN. INSTALLATION THIS IN EXISTINGVAL / MI SPECIFIC OD WCIFIC CRAMTY OF 9.50 AS ) I' DOUG— FIR OR SOUTHERN PINE No. 2, OR EQUAL. I I ® D 0 CEILING MOUNTING 1NeTel I eT1n� I I 1 1 I ' I 1' MIN.I I I To Z"Is I I 1 I I EXISTING I I GLASS— I I )1 Ea EO _ 1/4'0 TAPCON WIT 1/2' Min PENETRATION 2' NIN-- OF.THREADED AREA INTO WOOD DECK. (SEE SCHEDULE ON SHEET 12) 9 FLOOR GONN= i]xia�T 1 MIN. SPAR TIC TO CLAS Ilk 2'x4' MIN, WOOD STUDS. (AS APPLICABLE) EXISnNG CUSS — C— F I' MIN. SEPARATION O- TO GLASS 8 ® SOFFIT MOUNTING I JLSTAL�N N EXISTING I—SEPAAATION— CLASS\ I TO GLASS I ALTER 2'xe' MIN. WOOD ANCHOR DECK REQUIRED i LOCATION (NO FINISH © • 1 ]/a MN. ALLOWED) ]/3 Mw. AIOx]/4' HEX 2'x6' MIN, WOOD DECK ASNTR HEAD TEK ` EDGE OF PECK REQUIRED (NO FINISH ALLOWED) SCREWS a 12' a.c IF APPLICABLE EDGE OF DECK 1 2' IF APPLICARI TTER SH I� EE: SHEET 3 FOR TYPICAL SHUTTER ASSEMBLY 1/4•a TAPCON W/I 1/2' Ntn. PENETRATION 2-MDUNfISECTIONS CAN BE Um OF THREADED AREA INTO WOOD DECK, 2' MIN,- IN ANY WAY TO SUIT ANY INSTALTATION (SEE SCHEDULE ON SHEET' 12) _�_ � 1D FLOOR •ONN TION 1/4'0 TAPCON / ANCHOR a a' O.C. / W/ 1 1/2' MW. Y PENETRATION INTO STUDS OR W/ MIN, 1/2' PENETRATICN TO 1/2- Cox \ F" PLYWOOD IF NO / \ STUDS EXIST. / E EQ 1/2' MIN. COX PLYWOOD. { 1/2. MIN, ;I04f2' S.M.S. R OR 6�"R Q a Ifi O.0 OR OOR(Df + . INl�9] IN- D f1—Q 'TIO DETAI 1 W & 4W 2'x4' MIN. WOOD STUDS HE O'D 1/4'0 TAPCON ANCHORS EXISTING GLASS W/ 1 1/2' MIN. PENETRATION a 12' O.C. P MIN. SEPARATION TO CLASS AV DECK IF'OR OCFM B APPLICABLE "LI END CONNECTION D Tell gy A.S.S �L` 4 TILLIT TESSTIN• ENGINEERING 033a N,H]UL,)st.30.% wcNEEIvGDO� .A �m•rlean Shutter Spiorna " [ • �L. yG,,7.,;a xWO Phan : (305671-13]0 . Fax 1 -Gma,Y: aAea am E13 As 7oclatian1 in@.(]09JG71-Is71 4268 Wastroeds Drivameamoaa West P.E. SEAL/SIGNATURE/DATE WALTER A-000571s . P. E FLOROA Ua- / 44157 Palm Beach, FL 33407 F.9.C.(Nan High Velocity Hurricane Zone) 0 2003 EASTERN METAL SUPPLY.-INC. BERTHA MVTU Accordion Shutter Systen EY. N. OC3CRIpTION OATS 0— 1 ° s n+o1. x/1>ral DATE: 7 to D: a DRAWING No 4 05-196