Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSQ OFFICE UU ONLY: ` Date: S a fj 00 I Fee Due: Receipt# Permit # .,ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and Zoning �b•,[p3-�31 J . 2300 Virginia Avenue �� ✓ � Ft. SCANNED Pierce, FL 34982-5652 Y Pierce, -462-1553 4 St. Lucie County APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 8609 Tompson Point Road Port St. Lucie, F1 34953 2. S/DNAME: Tompson Point Pud @ PGA dSITEPLANNAME: Kelly Residence 3. PROPERTY TAX ID #: 3327-704-0023-000-1 4. LEGAL DESCRIPTION (attach extra sheets if necessary): Tompson Point, Pud at PGA. Lot 22 5. PLAT 43-10 6. PAGE 7. BLOCK S. LOT 22 BOOK NO. NO. NO. 10 000 9. PARCEL SIZE: CRES Q FT. d • a5 LOT DIMENSIONS 10, SETBACKS (ACTUAL) FRONT: BACK: ". i6 RIGHT SIDE: LEFT SIDE: to 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab . WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X POOL ENCLOSURE N ❑ NEW M EXISTING 26 X 53 1378 ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X TOTAL SQUARE FOOTAGE OF CONSTRUCTION 1378 12. VALUE OF CONSTRUCTION: $ 11,095.00 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 2119107 d OWNER INFORMATION Kevin & Nancy Kelly •` NAME: ADDRESS: 8609 Tompson Point Road 8 a LA ��q L FL r 3 953 CITY: Port St. Lucie v I l �am5 t-=1STATE:-ZIP PHONE (DAYTIME):: (172 1336-0078 ,/ - - - - email: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): CONTRACTOR INFORMATION 4763 STATE OF FLORIDA REG./CERT #: ST. LUCIE COUNTY CERT #: BUSINESS NAME: Pioneer Screen Co, Inc. II QUALIFIER'S NAME: Michael J Newman ADDRESS: 1682 SW Biltmore Street CITY: Port St. Lucie STATE: FL ZIP 34984 PHONE (DAYTIME): (772) 340-4393 FAX NO. 340-4626 email: Pioneerscreen@msn. com ARCHITECT/ENGINEER: BDQ, Inc ADDRESS: 1950 NE 170th .Avenue CITY: Williston STATE: FL ` ZIP 32696 PHONE (DAYTIME): (352) 529-0080 NOTE: IF APPLICABLE,. SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be.subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFFLGE ZONING USA ONLY = 12. r t r . SECTION a � TOWNSHIP 2 / _ Zb 3 RANGE 39 MAP NO. 3 3/53 Al ZONING' 1 LAND USE (� LOT CVG % Additional Permits rYes REPORT CODE BIMS FEE $ MISC FEES TOTAL FEES r BUILDING; & ZONING < REVIEW:, t`,s K v4 `- � ` Y ..,�, .$34. f._ ref .14' }_a^.,af' t.}i .: .x.:� �SN � ,..r{' ... �..3•`� .... � � zih FaSn. i3 �uiwe.t<i �:_`. REVIEWS ZONING ZONING REVIEWED BY PLANS EXAMINER MISC. VEGETATION VALUE OF CONSTRUCTION USING ICC TABLE DATE COMPLETE ` V �P ® ai ��o• INITIALS �4 PLAN REVIEW SPECIFICATION CHECKLIST. PLEASE PROVIDE ONE OF THE FOLLOWING: A2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (1) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4`' wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / O Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is i adequ a ondition to withstand the uplift and weight of the aluminum structur and said structure will not exceed the fo;p tint o h structure that was in existence prior to removal by the storm,8% /� SIGNATURE STATE OF FL , COUNTY OF • L. cC o The foregoing instrument was acknowledged before me this ay of M29 , O�by C-1h'�� Nn a pqnx1 who is erson own to me or who has duced as i Signature of Notary CZ 3 (SEAL) My Commas rt dl 3U413 mites 0dobU 29. 2008 IMPORTANT NOTICES: SIGNATURE STATE OF FLORIDA 11 COUNTY OF� .1 U l b . The foregoing tns went was acknowledged before me thisay off 2 , 20CE iy ho is personally known to me or who has p oduced Of Komi swxwt (SEAL) My Commis.'den DD3WI3 w w ExpirmOdDbW29.2005 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL_ BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. VlLW4ttK bUNLEN LAJ 11 t'Atat t71 03/26/200t3 11:J0 //2J404b2b AM EDWIN M. FRY /­ LEhK OF THE CIRCUIT COUP. -I, SAINT LIME C, y FILE # 3188662 04/02/2008 et 02.47 Prv. OR bOOK 2956 PLGE 1902 - 1302 D;,c T,;pr. tiC RECORDING. 51.7.Gt; 1VOTIC OF The undersigned hereby given notico that fi*ovemant +v111 be made to certain real propetl yy, and in accordancewith Chapter 713, Florida statutrs the tbllowing lttformadon is provided in be, Notice of commencement 1. DESCRnMON OF PROPERTY (Legal description and sbee addms) TAX FOLIO NUMBM-3 g 2. 'fie • C SUBDMSION•�� BLOCK -IUCT Mrj _IDLDG UNIT o��i 5�3..10 i 1151'� 2 GENERAL DESCRIPTIONOFI11 PROVEMENT;znStall Scr^ een_~ Pool Enclosure 3. OWNER INFORIWA,TION: , a. Narno -1— b. Address �— G interest in property d. Name and address of fcc simple titleholder (rf other I tan Omer) 3 '4• CONTP-ACTOR'S NAME- ADDRESS AND PROMNUMSER • Pioneer Screen Co Inc II 1682.�W Biltmare Street Port Srtint Lucie FL 34984 (772) 340-4393 5, SURETY'S NAME, ADDRESS AND PRONE NMIER AND BOND,4MOUN7': 6. LENDER'S NAME, ADDRESS AND PHONE NUMI IV. 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be smved as provided by Section 713.I3 (1)(a) 7., Florida Statutes: NAME, A,DDRM AND PHONE NUAI =: S. In addition to bimself or bersaK ownet dcdPntw the to lowiogto receive a copy of tho Lie aces Notice as provided in Section 71113 (I)(b), Florida Statues: NAlv1g,ADDRESS AND PHONENUMmEL. 9. Expiration date ofnatiae of cmmepeamaot (the a piratio z dato is 1 ymrftm the date of tc nftg unless a (fig'eent date Is spectiit�. . ZO SlgnAtnre'kChmer or, Owner's Arthorhmd ow1C Z Print Name and Plrovitle Signatory's Titie/Offrca State of PI M 1. Couaty of ) The ib going Insbvmctt was admowledged before me this _J day of A f nr 1� 20 By i ear ame of pets (Type of authatity„•c g, Owner, officrr, =Iee, attorney in foot) F llrt ame ofpatty�OnbcUff�ofwtom&ns trinnent was ettca tad I Pmngly down or produced the foliawing type of M: �Mama �12tXo --/'KeMrr J Stewart (Printed Public ' My Commmsion 00354413 Y ) (Siggabtce of:+Totaty Public) (4auli pia Expires October 29, 2008 Under peatdtics of pegwy, I declare 11a4 I have read the f0mg ring and that the facts in it are true to the best of m1 larowledge and belief (section 92.525, Florida Stamm). Signatote(s) of Owner(s or Owner(s)' Autborki d OMcwfD1rednr/PArtoer/Murager who signed above: -A DyKtX Ala Luc ,� L � u�a ur.mtronompteem (SI$n) (PAntedName) /ni J coy,. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 hftp://stiucieco.gov/ce Issued: 05/07/2008 Job Location: 8609 TOMPSON POINT RD Permit Type: Pool Enclosure Job Description: BUILDING PERMIT Conf A 695 Permit #: SLC- 0803-0317 City: PORT ST LUCIE NSTALLATION OF POOL ENCLOSURE - PO# 0803-0315 Page 1 S/D Tompson Point R- Reserve PGA Lot: 22 Block: Parcel: 3327-704-0023-000/1 Contractor NEWAN MICHAEL J PIONEER SCREEN COMPANY INC II (772) 340-4393 1682 SW BILTMORE ST PORT ST LUCIE, FL 34984 Property Owner NANCY L KELLY (772) 336-0078 7891 PEACEFUL VALLEY WILLIAMSBERG, MI 49690 Property Owner KEVIN C KELLY (772) 336-0078 7891 PEACEFUL VALLEY WILLIAMSBERG, MI 49690 Setbacks Left: 6.00 Right: 6.00 Front: Rear: 21.00 Zoning: PUD Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: 276F Flood Zone: X Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. i NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. yj 1950 N. E. 170 A VENUE, WILLISTON, FL 32696 ' PH 352 529-0080 FAX 352-529-0081 ENGINEERING, CONSUL TINGAND DRAFTING SERVICES FLORIDA ENGINEERING CERTIFICATE OFAUTHORIZATION NUMBER: 00008238 May 2, 2008 To: Joe Cisio, Head Plans Reviewer V C-LL�! -JOB St. Lucie County Building Department Re: Certification of 120-C engineering being identical to 140-B engineering Dear Joe: It is our understanding that many of the screen structures located within your jurisdiction are required to be designed to 120 mph wind load,_ exposure category "C". The engineering that we are supplying Pioneer Screen Co., II is for 140 mph wind load, exposure category "B". Based on the information contained in Table 2002.4, of the Florida Building Code 2004 Edition (the 2006 Amendments),_ the design pressures specified for these two design "categories" are identical, being 6 PSF for screen roof, 21 PSF for screen walls. Since the designation of the exposure "C" is for a Non -High Velocity Hurricane Zone (Non-HVHZ), then the entire design criteria is identical, and therefore, our 140-B engineering is all of the same design and specifications that would be supplied for 120-C. Please accept this sealed letter as certification that both design "zones" are identical in every area of both the design and specifications. We shall provide an original raised -seal copy of this cover letter with each permit package that is submitted for all proposed projects within this designated 120-C region. I hope this letter provides you with all of the information you require. Should you need any additional information, please contact either Pioneer Screen Co., II, the contractor, and they will let us know, or feel free to contact us directly at our office at the number indicated above, and as always, thank.,you for your time and consideration in this matter. t. if t_ 4" C 0 ti "A I,fDowdy, NE. r is ,No.-.° 2276V 1 �i•tR a� �� _ad t Code Compliance Division Review Comments 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 Page 1 http://stlucioco.gov/ce PROPERTY INFORMATION Address: 8609 TOMPSON POINT RD City'/ State / Zip; PORT ST LUCIE FL 34986 Parcel # : 3327-704-0023-000/1 Jurisdiction: St. Lucie County Zoning: PUD Lot # : 22 Block: APPLICATION INFORMATION Permit Number: 0803-0317 Activity Type: Other Permit Type: Pool Enclosure CONTRACTOR INFORMATION Contractor Name: NEWAN MICHAEL J Business Name: PIONEER SCREEN COMPANY INC II Business Addr: 1682 SW BILTMORE ST City / State / Zil PORT ST LUCIE, FL 3498 REVIEWS AND COMMENTS Owner(s): NANCY L KELLY KEVIN C KELLY Application Type: Building Permit w/o subs Other Activity: Stories: 1 Automatic Sprinkler System? Fax Number 772-340-4626 Review Tvoe Status Reviewed By Date Started Date Complete Date Released Documents Missing Pending t 04/01/2008 1 Comment NEEDS NOC Plans Examiner Review Incomplete Kathy Cicio 04/11/2008 04/11/2008 1 Comment POOL ENCLOSURE IS DESIGNED TO 140mph, EXPOSURE "B" - THIS POOL ENCLOSURE IS LOCATED IN A 120mph, EXPOSURE "C" WIND ZONE` 04/11/2008 2 Comment PROJECTION DIMENSIONS OF POOL ENCLOSURE FROM HOUSE DO NOT MATCH DIMENSIONS OF POOL DECK Zoning Review Complete Jodee Vorreyer 04/01/2008 04/01/2008 r: :,i kti+=:ice TRANSMISSION VERIFICATION REPORT TIME 04/11/2008 13:17 NAME FAX 4622885 TEL SER.# BROM5J411427 DATE,TIME 04/11 13:16 FAX NO./NAME 93404626 DURATION 00:00:19 PAGE(S) 01 RESULT OK MODE STANDARD ECM Code Compliance Division 2300 Virginia Avenue Ft. Pleree, FL 34882 Phone, (772) 462-1553 Fax. (772) 462.2522 http:11%tlucleco.govfee Review Comments ERNEERTY.rrVFORWATION Address; 8609 TOMPSON POINT RD City l Stata 1 zip; PORT 5T LUCIE FL 34986 Parcel # : 3327-704-0023.00011 Jurisdiction: SL Lucie County Zoning: PUD Lot #: 22 Block: APPLICATION L VFO Tram Permit Number, 0803-0317 Activity Type: Other Permit Type: Pool Enclosure CONTRACTOR rIVFORmATioN contractor Name: NEWAN MICHAEL J Business Name: PIONEER SCREEN COMPANY INC 11 DUSIn3Ss Addr: 1692 SW BILTMORE ST City 1 Stata 1 Zil PORT 5T LUCIE, FL 3498 REVIEWS AND COMMENTS Revi� Status 130euments Missing Pending 04/0112008 1 Comment NEEDS NOG Page I Owner(s): NANCY L KELLY - - KEVIN C KELLY Application Type: Building Permit w/o subs Other Aetivity: Storle6: 1 Automatic Sprinkler System? � Fax Number 772-340-4626 Reviewed 13 • T '11 A --y FILL u..r ILL �Y�iPI�Sh13YV dot•: aZ; :i«Mt 80N.''A01[Zrfl -0 fi P QiA:; It1l1GE, plar khe plat .: • tllareaf; .pa iaoordet�� In `M 'gack•43�� ; '_. ap .: pages 1O and 10A of the �, Public of'at,::laicle:Cgp1' ' . \ R 25.Ot� Record®� nayp�idq n LOT 21 % K P.4L tkP. r - ?OA�PSbN POINT P.li.�. ' AT "! � 'rJ3: wrn+ c'ta n t. NOT' VAiJO 14l1HCt1T 1HE , 7URB AdID 7fii� RIdNA1, RAIGM sEAt 1'l.20 �m e� OF A. UCEI D AltO`�fAPPER'a W:G,A. VILLAGE �� - PLAT BOOK: 43; PAGES 10 Z. BF.ARIN� L�iDVlN HER= AItE 1�FXi F+%di DF TOMP8ON .POINT•P;fI:D, 1 I �" CBm=N1.4'14'S3"W AT Pc:A. VILL40 ACCORDING TO' tNEJ°lAT.7HER�gF RE90411 IN PLAT AND 90A itobK 43,. PAO: AJ11p 1.OA'O>r 7HE;P.UBIR>7iECQi�f38. SP LUCK (p)(m) COUNTY..�pRIpA.: • �. >�''•'Lf�iAl. Ot�11cN' Kerr t9A6 Pt�ePJdiEli:d1<tr. zrl� '� S�rRVEYCR PER t4r� rt tre RF IItot sET s/6.� IRON RbO: sE7 N de o' . : 18# :Iqf . dr :sUi!{P`WA9 PRO�AitlMo. WI'IiriouT aJEf�EF1t, -OF A�1 AND cAP NTH I a if $3 S 0814 #11" W 177 9.3' (NA) is , 'M (PA> � 4.a' N,rr. s `--� d" ) (.O a"� ol�r'�Io w:t�ratnsccRa� t zn '�$2'OB" W ElAiH1SFlEI1 �iHp$-IT AS OR oWHk3iSH ' 1'a C✓aPta PAD ' 01'84' s .;. ELEI►ATKlD1$ BA dN eliECdIMRK6 PROM BY.81IElDER AS S1:1':BY<OTHt#RB:AS OWN'ON i?ROVFG� ON Et10 0;AS�9 L.M 7143 (F' N $. E1:BYATIONB. SHOW HERFdJir WITH AA fir :Ati PlIOpOtO.I?ER R=zon.00 �• INTO WENT. spauc�r�ta PLANS PREPAREQ r�r oTx�e NIo FIIIB+IISI�a Bltr'' 7HE L=49.00 %'ti ! ' `� : NO: 4lNp,�tOPgRi1l' LINwE9 HA� � 'V=IE `IAIPPi€JVEtAEnT1S eN SITF, OR eEYOND A QW N�R�cN. �T+'LID::ArCir3'T TNOSESHOYM � aRIC1P PAW�tS . C=4®.®8 �RlyEtyAY:• su1LOIN(1:VER Sld N • ICE E8I'A6LI Ea oN.: rlEo �rAL� INOLu4d; taLTER1OIi SNCCO A .'I 1FIE POUNDA7 s I01010 , MAW;. 6060 T'olnpean Pa�f. Road . Part &t.',W e; iHorldd 3�491M I �1i13}1N0 BEWAt . U1a(�I,ATTED °o• .t'. :5 11Et:OAtt;VARA,' 8809 Ff1E9�i1� 30' f OHT QARi4GL'� 1 ;SYLiRY..O:B.S. m :1o' PROPOSEp F.f : 28.80' _ ' ,(Y+1f{?OOL OEQIG� �RFj 3 PA710' v; PATIq� F.F. i18.7a' ' > LOT QRAD1Nr8 ' r R=t'0O.a® _" a:: .Lei: t22.84' a' ;.a.kz s ; 4 !: TRANS S [:� tAOpp: M. ROAD i.a7:o8' z C22.7Q ° I'A0 °°',er'tiid 6528' " W. seT O/e�:iRaN Rd4D 88'4B'i " W 950;3 (NA.. (R��t�) � W MIN. SETBACK ANb CAP 4YlTH -90 V43 Or, lQgvin ChdMae Kally ad'�lcnoy Lyynnn Kofly P (m Amerkan Pfdllaer 110- tgeuranlfo:Campany FRONT �( $E1 N do D W1TE! 19 7143 p. A F (Ra9i.�s m E" IN>� a Tide Oomp ny SIDES �_ _ . , care® Qr r#IAi 190010r i LOT as. CNR SIDES TOMPSON POINT RUM. AT � I he:s�y aer8 :ffidE titP attgdied it10UNDARY 9ilRVEY" or �o Q' �o d-�af ®5l-2u 5 P.G.A. VILLA► E I har6oA�+dd bd �prap to bue talA o�rsat to iho boat -of my ImoYN�pq,faeappalpa bailof as under nn REAR ) 5 or PLAT BOOK 43, PAGES 10 1C' U,E on: F nlary 18; :: I *, th�lhje'6oIlNDyAti A�10 10A SUItVL' maeb the n11n1mutn h ,. atendo* eet for9li In rule zNG. �-: TECH. d "' I Cmii�AiB Aro;eslsloitiel;S�lnueyor.and mapper 4 PRO% o EJwG .090"lratletl No. 00 AbbrOMMLO •SYMB SIip0 tlEflEO AflE NOT TO SCALE P.C. • — POINT OF CUflVAT1JRE Pg. — PAGE TYP. TS'pICAL CONc — GDNdREiE !I'�iF1SF.A � �+?It,... � kJ.B. - POINT OF REVERSE CURVATURE N�• _Lh NGN—RADIAL U. — " TY EA9E94fEt4T C LF; — CtlAIN`T:INK FEN FXEGTR i ` ` -- OPY . P C:1;; — POINT OF COMPOUND CURVATURE MAD. — RADIAL 0:£: : ORAINAOE 9 ' EMENT W.F — WOGD FENCE � g:0 FT. ninee:r� �V15d N.'... BY:. JNC7K7N SOH P:T. — POINT OF TANGQIFY = 6dADIUS P/U — ORAINA®E AHD t11fUTY EASEMENT C do O —CURB dc''GU1�fEei N;M. , PA r P01HT C<F IN7Eii5T10N L —ARC LEN011i PiF'. — FlNIIED FLdCR CATV FJi1fi4L"1f81Y'{f1.o,' SQUAB P.CI': — PE7iMADtENT'CONTROL POINT CA9CtL 3ELEVISION RISER F.H. Fl q — gELTA 6 i.=)9UILt31NG 3EF91iCR LINE T -� tElEPHdW RISER N & [i -. N gip', > rup�e.Architect� R FINAL t POINT ON UNl: AIL• . - DISCIR1' J1F R.P. —RADIUS POINT 4i9 a^ — CONCRBTE:HLOCK STRUCTURE TRANS 7RAP(9F8RMEii PAD F7<M. — eENCH..MARiG. • P.R.M, — PERMANENT 18E�ERENCE MONUMENT ri!%iY — R1pH1—GF=WAY (P(, • — (PIAi"11�V0/i71G1V, SilRlfiY JiF 8 9 C.B. — CHDRD. BEARING C — gENTER UNE �Ti' — MR,ASUREa P.P. — poW i PC1E F.B. - FlFiD :BOOK c,M. — CONCRETE MOIJIiMENT — CALCULATORS EL, — EL VAiION NG — NA1UftAl GROtJPfD M:N, — MAMHI9LE'. O Rg S DIfT OL 8 8/if¢ PIS — PLAT BOOK — A/c — �� co�DinaNER ��} I.C.v. IRSIGa�onr'•cord�ioL = . — A1AL: CO. 0ANc3ttla a c R�oEa n3'horierS Pr���t� .. _. ..... IVa..198 3 _ .. . : . on __ � 4;erlificaEe:.o�AuilrarJicii• PIONEER SCREEN CO., II SCREEN ROOF ENCLOSURE FOR: KELLE)' RESIDENCE 8609 THOMPSON PT. PORT ST. LUCIE, FL BUILDING DIVISION INSPECTION FOR ALUMINUM PRODUCTS INCLUDES ONLY VISIBLE CONNECTIONS AND DETAILS. ALL HIDDEN CONNECTIONSRESPONSIBILITY ARE THE RES®®NSIB OF THE ALUMINUM CONTRACTOR - S k cc N co OVERALL DESIGN COMPLIES WITH THE 2004o AMENDMENTS TO THE F.B.C. 2004 BUILDING,. CODE, FOR 140 MPH WIND LOAD (3-SECONb GUST), FOR EXPOSURE CATEGORY "B" DESIGN NOTES: 1. ALL DIAGONAL BRACING SHOWN IN BOTH THE ROOF AND o a WALLS SHALL BE 2 x 2 x .093 TUBE MATERIAL. �► 2. 18 x 14 MESH SCREEN 15 THE MAXIMUM ALLOWABLE DENSITY FOR THI5 ENCLOSURE'S DESIGN. 3. DOOR(S) MAY BE PLACED INTO ANY 5CREEN WALL PANEL EXCEPT FOR THOSE THAT CONTAIN DIAGONAL BRACING. THIS SYMBOL REPRESENTS THIS SYMBOL RI=PRESENTS DIAGONAL ® WIND BRACING (IN BOTH THE ROOF BEAM SPLICE LOCATIONS AND WALLS), 2 x 2 x .093 TUBE MATL. 21310, HOUSE FASCIA 24' 0' I i— — — — — — — — — — — — — — — — — — — — — — — — — --- ;�l I x 2 2x3x.010 x x x (TYP) x x x N N N N N N 2x3x.010 Ix2 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES, loll g 5i: LUC6E DOCt?� 2 Ty BUILDING Dlvlblpnq No 6o-v' ;a i Oil dOE OR MADE rff N m Q 0 co 2�❑ J N r �cy)u-9Z L� a�Z Coll ° 0 w~1-,N oL9 � a'�`c"o N ❑ _ F— (UR�dw < ZQ co) OlL ❑ Q J o L U r ° no u'WmZ ❑ z=w ag w0 r- LL FAE3RICATI®N / INSTALLATION REQUIRED GUIDELINES: NOTE: ANY JOBS THAT REQUIRE SITE -SPECIFIC DESIGN / ENGINEERING MUST BE • SUBMITTED TO THE ENGINEER OF RECORD FOR SUCH DE51GN CONSIDERATION PRIOR TO THE JOB BEING PERMITTED, FABRICATED OR INSTALLED. LEAD-TIMES FOR SUCH WORK WILL DEPEND ON OUR CURRENT WORK LOAD AT ANY GIVEN TIME., THE ITEMS BELOW ARE NOT PERMITTED ON ANY ENCLOSURE WITHOUT SITE -SPECIFIC IDE51GN 4 AUTHORIZATION FROM THE ENGINEER OF RECORD. I. NO SCREEN ROOF BEAMS SHALL BE LOCATED WITHIN 12-INCHES OF ANY OUTSIDE CORNER OF ANY WALL, FASCIA OR STRUCTURAL GUTTER. 2. NO CABLE BRACING SHALL BE USED ON ANY ENCLOSURE AT ANY TIME FOR THE RESISTANCE of ANY IMPOSED DESIGN LOADING. 3. THERE SHALL BE No SUBSTITUTION OF EITHER CONCRETE ANCHOR TYPE OR MANUFACTURER OTHER THAN THOSE SPECIFIED ON THESE ENGINEERED DESIGN DRAWINGS. 4. THERE SHALL BE NO SCREENING UTILIZED THAT IS FINER THAN 18 x114 MESH SCREEN WITHOUT SITE -SPECIFIC DESIGN (THAT SHALL BE DONE PRIOR TO THE JOB BEING FABRICATED OR INSTALLED) WITH JOB DRAWINGS BEARING THE ENGINEER OF RECORDS ORIGINAL SIGNATURE (IN BLUE INK) UNDER HIS EMBOSSED SEAL. 5. ALL SCREEN ROOF ENCLOSURES MUST BE POSITIONED ON THE EDGES OF THE CONCRETE DECK 50 THAT THE OUTER SURFACE OF THE SCREEN FRAME IS NO LESS THAT 2 3/4 - INCHES IN FROM THE EDGE, TO CREATE PROPER EDGE DISTANCE FOR THE SPECIFIED CONCRETE ANCHORS AT THE BASE OF EACH COLUMN. 6. ALL ROOF PURLIN5 IN THE ROOF AND CHAIR RAILS IN THE WALLS SHALL NOT EXCEED 8-FEET CENTER - TO - CENTER SPACING (SEE APPROPRIATE DETAILS ON OTHER SHEETS OF THIS DRAWING FOR SPECIFIED MATERIAL SIZES REQUIRED FOR ANY GIVEN APPLICATION. 1. NO SCREEN ROOF ENCLOSURE SHALL BE INSTALLED UTILIZING SEVEN-INCH STRUCTURAL GUTTER, AS IT IS NOT PERMITTED, OR STRUCTURALLY ADEQUATE UNDER THI5 ENGINEERING. THE ITEMS BELOW MUST BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO MEASURING 4 LAYOUT, FABRICATION OR INSTALLATION FOP, THE REQUIRED.51TE-SPECIFIC DESIGN. 1. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES ROOF BEAMS THAT EXCEED 40-FEET IN SPAN, AT ANY POINT ON THE ENCLOSURE. 2. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES WALL COLUMNS (UPRIGHTS) THAT EXCEED 12-FEET IN HEIGHT AT ANY POINT ON THE ENCLOSURE.' 3. ANT ENCLOSURE THAT -UTILIZES ANY CARRIER BEAM (A BEAM THAT ACTS AS SUPPORT FOR ANY OTHER SCREEN ROOF BEAM) AT ANY POINT ON THE ENCLOLSURE. NO CARRIER BEAM SHALL BE PERMITTED TO BE MOUNTED TO THE FASCIA OF ANY HOST STRUCTURE (AS PRIMARY SUPPORT). 4. INSTALLATION OF ANY SCREEN ROOF ENCLOSURE ON AN EXISTING HOUSE FASCIA WHERE THE OVERHANG EXCEEDS 2-FEET. NOTE THAT IF THE EXISTING RESIDENCE WAS CONSTRUCTED UNDER ANY BUILDING CODE PRIOR TO F.B.C. 2001, THE JOB, MAY REQUIRE FOURTH -WAIL TYPE CCNST., AS THERE IS NO WAY TO CERTIFY THE ABILITY OF A H05T STRUCTURE THAT WA5.ONLY 5UILT TO WITH- STAND 110 MPH WIND LOADS OR LESS, (AS WAS REQUIRED UNDER PREVIOUS BUILDING CODES) TO RESIST THE IMPOSED LOADS OF AN ENCLOSURE THAT IS DESIGNED TO WITHSTAND THE LOADS IMPOSED UNDER THE 140 MPH WIND LOAD SPECIFIED IN THE CURRENT BUILDING CODE. II6NAP/ LAP JOINT �� CONNECTION NOTE: ALL FRAMING MEMBERS ON ANY ENCLOSURE THAT UTILIZE SNAP OR LAP JOINT IN THEM SHALL HAVE 012 TEKS INSTALLED THRU THE SNAP OR LAP CONNECTION AT 18 INCHES ON CNTR, (TYP). THESE TEK SCREWS ARE TO BE PLACED ON BOTH EDGES OF THE UPRIGHT (BOTH THE INNER AND THE OUTER EDGE) IN ALL CASES. THI5 SPECIFICATION APPLIES TO UPRIGHTS AND BEAMS BOTH. — MINIMUM FOOTER TAF3LES MONO MAX. BM. FOOTER SPAN V x 8' WITH lU 050 CONT. UP TO 38' 8' x 12' WITH (U SO CONT. UP TO 41' 10' R 12' WITH, (1) 050 CONT. UP TO 48' 12' x 12' WITH (2) SO CONT UP TO 55' ISOLATED MAX. BM. FOOTER(') SPAN 12' x 12' WITH (2) S' COLT. UP TO 30' 12' x 16' WITH 31' TO 39' cONT. 14' x I&, WITH 40' TO 44' (2) 05o CONT. 16' x 16' WITH 144' TO 52' (2) 059 CONT. IF A JOB EXCEEDS THESE PARAMETERS, THE FOUNDATION MUST BE SITE-SF'ECIFICAI.I.Y DESIGNEp BY THE ENGINEER MONOLITHIC FTG. LOAD CAPACITIES ARE BASED ON A MIN. OF 3 FEET OF CONT. CONCRETE, 2,500 P51 MINIMUM, W/ WIRE OR FIBERMESH REINFORCEMENT (s)ISOLATED FOOTERS MAY BE USED ON EDGE OF EXIST, CONC. SLAB OR UNDERNEATH THE PERIMETER OF BRICK PAVER DECK (ALL SIDES) THE ENGINEER OF RECORD WILL NOT BE ABLE TO CERTIFY THE STRUCTURAL INTEGRITY OF ANY EXISTING CONCRETE DECK / FOOTINGS THAT WERE INSTALLED WITHOUT PERMIT6, AS THERE „WOULD., BE ,NO RECORDS TO VERIFY CONCRETE THICKNESS', FOOTER SIZES AND THE SIZE AND QUANTITY OF STEEL RE -BARS THAT WOULD'BE REQUIRED UNDER THE CURRENT BUILDING CODE STANDARDS. SCREW SPACING AND EDGE D15TANCE 5PEC.'5 THIS TABLE 16 BASED ON THE PROPERTIES OF C-1022 LOW CARBON STEEL 611E AND SELF -DRILLING (TEK) SCREWS, WHICH ARE AN INDUSTRY STANDARD 6-CREW. SCRI_W SIZE NOMINAL SCREW 'DIAMETIER,?k) MIN. EDGE 'DISTANCE MIN, CENTER-TO- CENTER DISTANCE 08 m.l5fo 5/16' 1/10° 010 0,180 3/6, 1/2' 012 0.219 1/2' 5/6, 014 1 0.250 1 5/8' 1. 3/4' INTERNAL. CONNECTION SPECIFICATION (UTILIZING SCREW BOSSES) ALL INTERNAL CONNECTIONS UTILIZING THE EXTRUDED 5GREW 5055E5 SHALL HAVE 010 SM5 SCREWS, WITH A MINIMUM EMBEDMENT INTO THE SCREW 5055 OF 1 3/4" (UNLESS OTHERWISE SPECIFIED ON ANY CONNECTION DETAIL). ALL SCREW 5055E5 IN A GIVEN EXTRUSION MUST BE FILLED (EXAMPLE: THE 2 x 3 x .010 CHAIR RAIL / ROOF PURLIN THAT HAS 61X SCREW 5OSSF5, MUST HAVE SIX OF THESE 010 SMS SCREWS INSTALLED AT EACH END OF THAT COMPONENT, AT EACH CONNECTION). SCREEN PANEL INSTALLATION SPECIFICATION: PLEASE NOTE THAT ALL SCREEN PANEL OPENINGS (BOTH ROOF AND WALLS) SHALL BE INSTALLED ON ALL FOUR SIDES WITH SPLINE (INDEP- ENDANT OF ALL SURROUNDING PANELS). THE ONLY FRAMING COMPONENTS THAT ARE -NOT REQUIRED TO HAVE SPLINE INSTALLED IN THEM ARE ALL OF THE DIAGONAL WALL AND ROOF BRACING. SIGN DISCLAIM Ld CONCRETE ANCHOR SPECIFICATIONS: ALL CONCRETE ANCHOR5 SPECIFIED ON THI5 DETAIL SHEET ARE MANUFACTURED BY 'RED HEAD' ANCHORING Im SYSTEMS, AS ALL LOAD CAPABILITIES ARE BASED ON o TEST DATA FURNISHED BY RED HEAD IN THEIR PRODUCT AND RESOURCE BOOK. NO SUBSTITUTIONS OF ANY OTHER MANUFACTURER'S CONCRETE ANCHORS IS PERMITTED WITHOUT SUBMITTAL OF THE COMPANY'S TEST DATA (TO VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN, SIGNED AND SEALED LETTER OF AUTHORIZATION FROM THE ENGINEER OF RECORD. ANY UNAUTHORIZED ANCHOR , SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH THIS DESIGN. THE ANCHORS TO BE USED FOR APPLICATIONS s di SPECIFIED IN THIS ENGINEERING DESIGN PLAN ARE AS FOLLOWS, °° 2 C-2 1/4' DIA FASTENERS: RED HEAD ITW TAPCON (SEE INDIVIDUAL DETAILS ® ® FOR MINIMUM .EMBEDMENT DEPTH INTO CONCRETE)+ 3/8' DIA. FASTENERS: 3/8' TRU BOLT WEDGE ANCHOR (SEE INDIVIDUAL U- J to < o DETAILS FOR QUANTITY OF FASTENERS NEEDED) w U. (MINIMUM EMBEDMENT SHALL BE 3' INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) 3 3/8' LARGE DIAMETER TAPCON (LDT) (SEE INDIVIDUAL u' a DETAILS FOR QUANTITY OF FASTENERS NEEDED) O w iE (MINIMUM EMBEDMENT SHALL BE 21i2' INTO CONCRETE w UNI_IE55 OTHERWISE SPECIFIED IN ANY DETAIL)_ - 2— F a o FOR BRICK PAVER INSTALLATION: FOR INSTALLATION ON A BRICK PAVER DECK, THE ONLY FASTENERS THAT WILL MEET THE DESIGN CRITERIA INDICATED WITHIN THESE DESIGN SPEC.'S 0) ARE THE REP HEAD TRU BOLT WEDGE ANCHOR (3/8' x i'), WHICH BASED ON 1/8' ANGLE, I x 2 O.B., 211/a' THICK BRICK PAVER AND A MAXIMUM MORTAR BED THICKNESS OF 3/4'. THIS SCENARIO WILL STILL MEET THE MINIMUM FASTENER EMBEDMENT. IF ANY OF THESE CONTRIBUTING FACTORS EXCEED 3�q�gJJ THE pIMENSIDNQL BREAKDOWN INDICATED, THE JOB MUST BE PRESENTED W . . V_ TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC ANCHORING DESIGN. �cLLA EXIST. HOUSE FASCIA NOTES: co ® � ' '�' IT SHALL BE THE RESPONSIBILITY OF THE IN5TALl ING CONTRACTOR TO INSPECT AND INSURE THE CONDITION ` OF THE EXISTING FASCIA, TO DETERMINE IF IT IS IN GOOD ENOUGH CONDITION TO SUPPORT THE PROPOSED SCREEN ENCL05URE (PRIOR TO ITS INSTALLATION) 1I 1 THERE 15 NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IN THIS ENGINEERING DESIGN DOCUMENT REGARDING THE ABILITY OF ANY HOST STRUCTURE TO RESIST THE BUILDING CODE SPECIFIED DESIGN LOADS IMPOSED BY ANY PROP05ED SCREEN ENCLOSURE. SUCH CERTIFICATION WILL BE DEPENDENT ON AVAILABILITY OF ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS, AS WELL AS ORIGINAL PERMIT AND INSPECTION RECORDS FOR THE H05T STRUCTURE. CERTIFICATION OF THE HOST STRUCTURE, IF IT IS REQUIRED, WILL ULTIMATELY BE POSSIBLE ONLY IF THESE RECORDS CONTAIN ALL THE INFORMATION NEEDED BY THE ENGINEER TO PERFORM ALL OF THE NECESSARY ANALY515 TO DETERMINE IF SUCH CERTIFICATION 16 EVEN POSSIBLE. "m ® I wiw 6 GENERAL NOTES AND IDE51GN FARAMETER5: I. THE OVERALL DESIGN COMPLIES WITH THE 200(o AMENDMENT TO THE FLORIDA BUILDING CODE 2004 (CHAPTER 16 AND 20), AND 15 BASED ON THE FOLLOWING PARAMETERS: A. WIND SPEED: 140 M.P.N., 3-SECOND GUST B. EXPOSURE CATEGORY 'B' C. DE516N PRE66UREB A5 FOLLOWS: a) SIMULTANEOUS WIND LOADING 9 (b P.S.F. FOR SCREEN ROOF AND 21 P.SR FOR SCREEN WALLS b) 300 LB LOAD APPLIED VERTICALLY DOWNWARD ALONG ANY ONE FOOT (12-INCHES) OF ANY PRIMARY MEMBER (EXCLUDING DIAGONAL WIND BRACING, WHICH 15 TREATED A5 A 'STRUCTURAL MEMBER' UNDER 2006 AMENDMENT DEFINITIONS. D. MAXIMUM ENCLOSURE HEIGHT SHALL NOT EXCEED 30-FEET E. ALLOWABLE DEFLECTION OF 'L / 60', AS SPECIFIED I TABLE 11610.1, FOR NON -HIGH VELOCITY HURRICANE ZONES. _ F, CONTINUOUS LOAD PATH IS PROVIDED, 2. MATERIALS (UNLESS OTHERWISE 5PECIFIED' BY THE ENGINEER OF RECORD): A. ALL EXTRUSIONS SHALL BE ALUMINUM ALLOY 06063-T6 (NOTE THAT THE SPLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALLOY %061-T(o, IF THIS MATERIAL 15 MORE READILY AVAILABLE TO THE CONTRACTOR) (SEE COMPONENT SHAPES AND SIZES AT RIGHT). B. FASTENERS SHALL BE ALUMINUM ALLOYS 2024-T4 4 1015-T6„DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL, OR 300-SERIES STAINLESS STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE APPROPRIATE MEANS FOR SEPARATION OF D1551MILAR MATERIALS AS THEY ARE DEFINED IN SECTION *2003.8.4. THE CONTRACTOR MAY IMPLEMENT ANY OF THE MEANS SPECIFIED IN THIS SECTION. ANY ALTERNATIVE MEANS MUST BE ACCOMPANIED BY A LETTER OF CERTIFICATION FROM THE PRODUCT'S MANUFACTURER (THIS LETTER MUST BE SIGNED AND 5EALED BY A FLORIDA LICENSED STRUCTURAL ENGINEER), WHICH 5TATE5 THAT THEIR PRODUCT MEETS / EXCEEDS ALL OF THE REQUIREMENTS SPECIFIED IN THE ABOVE - LISTED SECTION. THIS LETTER SHALL ALSO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD FROM. B.D.Q., INC. C. SCREEN CLOTH SHALL BE VINYL COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 x 14 (58% OPEN). 3. ALL FASTENERS THAT PASS THROUGH ANY EXTRUSION INTO CONCRETE, MASONRY, WOOD, STEEL, ALUMINUM OR ANOTHER EXTRU51ON SHALL HAVE A 5/6-INCH DIAMETER WASHER, MINIMUM (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD), AND SHALL BE NO MORE THAN 18-INCHES CENTER - TO - CENTER SPACING. 4. ALL FASTENERS ADJACENT TO UPRIGHTS THAT DO NOT REQUIRE REINFORCING ANGLE CLIPS, SHALL BE PLACED WITHIN TWO (2) INCHES OF THAT UPRIGHT (TYP. FOR BOTH 51DEW. 5. SCREEN DOORS) MAY BE LOCATED IN ANY SCREEN WALL PANEL, EXCEPT FOR THOSE THAT CONTAIN DIA60NAL WIND BRACING CK-BRACING'). ALL DOORS SHALL BE SELF -CLOSING AND SEI-F-LATCHING, DOORS INSTALLED IN AN ENCL05URE THAT SURROUNDS A POOL / SPA SHALL HAVE DOOR LATCHES INSTALLED FIVE (5) FEET ABOVE THE FLOOR, MINIMUM. 6. COPIES OF THIS ENGINEERING SPECIFICATION / DESIGN DETAIL ARE TO ONLY BE CONSIDERED VALID FOR PERMITTING OR DESIGN CERTIFICATION PURPOSES WHEN ALL SHEETS OF ANY SUBMITTED SET BEARS THE ENGINEER'5 ORIGINAL SIGNATURE (IN BLUE INK), UNDER HIS EMBOSSED SEAL. B.D.Q., INC. SHALL NOT BE RESPONSIBLE FOR NON -ORIGINAL COPIES THAT ARE SUBMITTED, THAT HAVE ANY UNAUTHORIZED CHANGES, ALTERATIONS OR DELETIONS ON THEM. 1. THESE ENGINEERING DETAIL DRAWINGS ARE ONLY VALID IF THE DATE.ACCOMPANYING THE ENGINEER'S ORIGINAL -SIGNATURE 15 LESS THAN 90 DAYS OLD. NO BUILDING OFFICIAL OR BUILDING DEPARTMENT SHOULD ACCEPT COPIES THAT ARE OLDER THAN THIS, AND SHOULD REQUEST THE SUBMITTING CONTRACTOR OBTAIN UPDATED / CURRENT ENGINEERING. 8. ALL ENGINEERING SPECIFICATIONS AND DETAIL DRAWING CONTAINED WITHIN THIS ENGINEERING DOCUMENT ARE THE BOLE PROPERTY OF B.D.Q., INC. ANY UNAUTHORIZED COPYING OR OTHER REPRODUCTION IN PART OR WHOLE OF THESE DOCUMENTS WILL NOT BE PERMITTED AND WILL BE PROSECUTED TO THE FULLEST EXTENT ALLOWED BY LAW. S. THERE SHALL BE NO'REDI5TRIBUTION OF THESE ENGINEERING DOCUMENTS BY THE PERSON OR COMPANY THAT ORIGINALLY PURCHASED SIGNED AND 5EALED COPIES FROM R.D.Q., INC., WITHOUT EXPRESS WRITTEN AUTHORIZATION FROM B.D.Q., INC., AND THE ENGINEER OF RECORD. WALL COLUMN SCHEDULE (ALLOW. COLUMN HEIGHTS VS. WALL PANEL WIDTH) L/80 MAX. ALLOWABLE DEFLECTION (140 MPH, EXP.'B", 21 P.S.F. DESIGN LOAD) DIMENSION COLUMN HEIGHT va WALL PANEL WIDTH (DESIGN PRESSURE - 21 PSM SIB Tf Tw IT 0' T 6' T 0' G 8' 6-0- 5-6- 5' 0' 4' 6' 4' 0' 2X4 L .100 .045 T 5' 1' 8' SIT 9' 0' SIB' 9' II' 10' 5' 2x5 L A 16 .050 9' 0' 9' d' 9' 8' 10' 0' 10' 5' 10' II' II' 5' 12' 0' 12' 9' 2X8 L .120 .050 9'q2'0 9' 8' 10' 0' 10' 5' 10' 9' 11' 3' II' 10' 12' 5' 13' 2' 20 L A20 .057 I01 6' 10'Il' 11'3' II' 9' IT Y 12' II° 13' 6' 14'4' 2x8 L .224 .072 12'12' IF 13' 3' 13' 9' 14' 4' 15' 0- 18' 10' 19' 10' 21, 0' 2x9 L L .209 .672 15' , 15' T 16' I' 16' 8' IT 4' 18' 2' IT 0' 200' 21' 2' 249 L H .306 .082 18' 1' 19' 2' IV 11- 20' l' 21' 5' 22' 4' 23' 5' 24' V 26' 2' 2X10 L .389 .092 22' 0' 22' 9' 23' 6' 24' 4' 25' 4' WWI 21' 8' 29' 1' 30, 9' TF COMPONENT 6HAPE5 AND 6PEGIFIGATI®N5 m93 .044 .040 Tw O 3' 22' 2' � 3� Ix3O.E3. Ix2O.E3. � 2 x 2 x .0133 TUBE NVALUES FOR FLANGE THICKNESS) AND 'Tw' (WEB THICKNESS) FOR THE VARIOUS DIACx. Bi�ACINC� THE ACTUAL 5ELF-MATING CV) SIZE SELF -MATING MATERIAL ARE INDICATED ON THE UPRIGHT HEIGHT AND BEAM SPAN TABLES. m a� z r BEAM SPANS AND COLUMN SIZES ON THIS SHEET ARE BASED ON SIMULTANEOUS _ ----- �L.0,4pINCa, AS DEFINED IN TABLE 02002.4, F.B.C. 2004, FOR 140 MPH WINDS, FOR _ uncr aromab-riInn 1111T, i EXP0511RE CATEGORY 'B' (2I P.SP. WALLS, 6 P.SF. ROOF, 300L8 CONCEN. LO,Aq) HOST STRUCTURE WITH STRUCTURAL GUTTER MANSARD ROOF BEAM SPAN MANAARD BEAM SPANS ARE 5A5ED Lu Lu ON A MAXIMUM SPLICE ANGLE OF 30' FOR HALF -MANSARD BEAM SPANS, USE VALUES SHOWN IN 'MANSARD BEAM SPAN TABLE (SAME MAX. SPLICE ANGLE Lu (30°) APPLIES TO HALF -MANSARD [BEAMS) d HOST STRUCTURE WITH Lu STRUCTURAL GUTTER kn w PEAK / GABLE ROOF BEAM SPAN A , ,0 , All FLAT SIMPLE ROOF BEAM SCHEDULE MR RAT @; AR°A, IAO"fix (140MPH, E aV) DIMENSION ROOF PANEL WIDTH va BEAM SPAN (FOR MAX. WALL HEIGHT OF 116' 0n SIZE Tf Tw 8'0' TW T0` 6'6' 1 V0' 06- 60' 4'6' V0' 2x4 L .100 .045 12, 9' 1313, w 9' 14' 4' 15' O' 15' 8' 16' 5' IT 4' 11' 11' 2X5 L .116 .050 IFS' 16' 4' IT O' ITV IS' 4' 19' 2' 20' 2- NIB' 22' 1' 24 L .120 AW IV 4' IT O' ITT 18' 2' I9' 0' 19' II' 20' 9' 22' 0' 23' 3' W L .120 .067 IW O' 15' 5' IS' 2' 19' II' 208' 21' 8' 22' 9' 24' 0' 25' 4' 2X6 L .224 072 22' 0' 22' 8' 23' 5' 24' 4' 25' 4' 1 26' S' 1 2T V 2V 2' 30' 9' 24 L (L) .209 A72 26' 9' 21' 1' 26' b' 29' 1' 30TI 32' 2' 1 33' 8' 35' 4 31' 5' W L (H) .306 .082 33' 2' 34' 3' 35' P 3611, 38' 2' 39' 9' 41'. T 43' T 46' 2' 2X10 L . 9 39' 2' 40' 4' 41' 1' 43' 2' 44' 9' 140"I'l 4V 1' 51' 0' 53' 9' --1) REPRESENTS $PAN VALUES THAT ARE DEFLECTION -LIMITED BEAM SPAN CALCULATION NOTE: THE SPANS IN THESE TABLES ARE BASED ON BOTH THE HOST STRUCTURE MOUNTING POINT AND WALL HEIGHT BEING THE SAME MEASUREMENT MANSARD / CENTER PEAK (GABLE) ROOF SEAM SCHEDULE Lw max. (140 MPH, W. 931 ''THIS SPAN TABLE IS LIMITED TO A MAXIMUM !VERTICAL RISE OF 3' 0' (,V)' DIMENSION ROOF PANEL WIDTH va BERM SPAN (FOR MAX. WALL HEIGHT OF 8' 01 SIZE Tf Tw V 0' ?"W T 0" 8' 6' V 0' 6 8' S' o' 4' 6' 4' 0' 2x5 L .116 .050 816. 10' 6' 12' 1' 14' 9' 2x6 L .120 .050 10' 0' Il' 10' 14' 0' 16' 0' 2x7 L .120 .057 8' 3' 100' 11' 8' 13' 4' 15' 2' IT O' III 2X8 L .224 .072 14' 0' 15' 2' 16' 4' ITS' IT 2' WIT 22' 4' 24' 3- 26' 4- 2X9 L (L) 109 .072 20' 9' 22' 0' 23' 2' 24' 6' 26' 0' 21' 1' 29' 6' 31' 5' 33' 11' 2x9 L (H) .308 .082 28' 9' 301' 31' 5- 32' II' 34' 6' 36' 4' 38' 6' 408' 43' 6' 2x10 L 35' 8' 1 31' 2' 1 38' 6' 40' 2' 42' 0' 1 44' 2' 46' 3- 48' II' 1 51' 8- MANSARD / CENTER PEAK GABLE ROOF BEAM SCHEDULE Lu nuax. (14o MPH, Ev. si "THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL. RISE OF V 0' (361. DIMENSION ROOF PANEL WIDTH va BEAM SPAN (FOR MAX. WALL HEIGHT OF 12 0") SIZE Tf Tw 8' 0° T 6" T O' 6' 6' 6' 0' 6 8" 5 0' 4' 6' N W 2x5 L .116 .050 2x6 L .120 .050 !14'12' 2s(7 L .120 . 557 II' 0° 2x8 L M4 .072 8.01 0' 2' . 12' 2' 14' 3' IVY 18' 4' 20' 1- 23' 2' WL (L .209 .072 I6' 2' 11, 1' 19' 2' 201,31 21' 6' 24, 5' 26' 6' 281131 31' 5' 2x9 L H .306 .082 25' 1' 21' 2'./ 28, 1' 30' 3' 32' 2' 34' 2' 36' 3' MIT 41' 6' 2x10 L •M -M 1 33' 3' 34' 9' 1 36' 5-1 3V 2' 1 40' 1' 1 42' 3' 44' 1' 41' 2' 49' 11' MANSARD / CENTER PEA({ (GABLE) ROOF BEAM SCHEDULE Lu mAx (14o MPH, Exp. si THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL RISE OF TO' (36')" DIMENSION ROOF PANEL WIDTH va BEAM SPAN (FOR MAX, WALL HEIGHT OF IV 01 SIZE Tf Tw 1 8' 0' T 6' T 0' V 6° 6' 0' 6 6' 5' 0' 4' 6' 4' 0' 20 L .120 .067 2x8 L 224 .072 10' 0' 15'2' 16' 3' IS'4' 2x9 L L M .072 9' 4' II' 9' 14' 0' 16' 3' IS' 5' 20' l' 23' 2' 25' 9' 18' 8' 2x9 L (H) .3W .082 22' 2' 23' 8' 25' 6' 2l' 5' 29' 5' 31' 6' 3I'll' 36' 6' MIT 2X10 L .389 .092 30' 6' 32' 3' 34' 0° 35' II' 31' II' 40' 1' 42' 8- 45' 5' 48' 8- I MANSARD BEAM SPANS OF LESS THAN 8' 0' ARE OMITTED FROM THIS TABLE wo 9 �Lu®92 5m� cDgzvg �- g :3 Lu °a' d WCEO ei LLL co Q 06I,co it Lu zF_a w UP TO I(o' BEAM SPAN 16' TO 24' BEAM SPAN 24' TO 32' BFAM SPAN 32' TO 40' BEAM SPAN O-INDICATES WALL PANEL THAT SHALL HAVE DIAGONAL. K -BRACING IN IT UP TO 8' WALL HGHT S' TO 12' WALL HGHT EXIST. HOST STRUCTURE EXIST, HOST STRUCTURE EXIST. HOST STRUCTURE NUMBER OF PANELS VARIES EXIST. HOST STRUCTURE EXIST. HOST STRUCTURE 1>4z 41 EXIST. HOST STRICTURE TOTAL NO. OF 5AY5.VARIES THREE l3) SAYS ON EACH END OF OUTER -MOST WALL SHALL HAVE DIAG. BRACING EXIST, HOST STRUCTURE f TOTAL NO. OF BAYS VARIES THREE (3) BAYS ON EACH END OF OUTER -MOST PANELS AND TWO (2) PANELS IN SECOND OUTER -MOST ROW OF PANELS SHALL HAVE THE DIAGONAL BRACING (AS SHOWN) THE BRACING SCHEMATICS SHOWN ABOVE ARE THE SAME BRACING CONFIGURATION, REGARDLESS OF ROOF TYPE (MANSARD, PEAK, DOME, FLAT, ETC.) DESIGN NOTE: ALL THRU-SOLT5 PASSING THROUGH ANY ALUMINUM MATL. WITH A WALL THICKNESS LESS THAN .m90, SHALL HAVE A 1118-INCH (OUTSIDE DIA.) FENDED WASHER (SEE GENERAL NOTE *2 ON SHEET 02 REGARDING SEPARATION OF DISSIMILAR METALS). THE CONTRACTORS MAY, IF THEY CHOOSE, INSTALL THE ANGLE CLIPS FOR THE DIAGONAL TUBE BRACING (WHERE IT ATTACHES TO THE SELF - MATING SCREEN ROOF BEAMS) WITH THE THRU-1501_T5 ONLY PASSING THROUGH ONE HALF OF THE BEAM. TH15 15 A STRUCTURALLY ADEQUATE ALTERNATIVE, AND WILL PERMIT INSTALLATION OF THESE ANGLE CLIPS IN THEIR SHOP, DURING FABRICATION (PO6515LY SAVING TIME DURING INSTALLATION IN THE. FIELD). IN UPPER ANGLE CLIP TO BE PLACED AT SAME ANGLE AS THE MANSARD LEG OF THE SCREEN ROOF BEAM 2 x 3 x .010 EVE RAIL 2 x 2 x '/a' ANGLE CLIP, CUT AT A 45' (+/-) ANGLE AND ATTACHED TO THE 2 x 3 x .010 EVE RAIL WITH ONE (1) '%4' DIA. THRU-5OLT, WITH FENDER WASHER (SEE DE51GN NOTE ABOVE elij NOTE'. ALL DIAGONAL BRACING SHALL BF ATTACHED VIA THE 2 x 2 x 1/8" ANGLE GIPS, AS SHOWN, AND SHALL- HAVE EACH END ATTACHED TO EITHER THE SCREEN ROOF BEAM OR TO THE EVE RAIL. NO DIAGONAL. BRACING SHALL BE ATTACHED TO ANY OF THE ROOF PURLINS 2 x 3 x .010 SCREEN ROOF PURLIN 2 x SM5 SCREEN ROOF BEAM (TYP) SPLICE JOINT 2 x 2 x'4' ANGLE CLIP, CUT AT A 45° (+/-) ANGLE AND _ ATTACHED TO THE SCREEN — ROOF BEAM WITH ONE lU 114' DIA. THRU-DOLT, WITH FENDER WASHER (SEE DESIGN NOTE ABOVE 2 x 2 x .093 DIAGONAL ROOF BRACE, CUT AT 456 ANGLE (+/-) AT EACH END AND ATTACHED TO EACH ANGLE CLIP WITH A 1/4' DIA. THRU-BOLT, AS SHOWN TYPICAL ANGLE ARTICULATION TO CREATE UPWARD ANGLE N DESIGN NOTES: - AI 2 x 3 x .m7m SCREEN L-DIAGONAL= BRAGING,-USED-EITHER IN -THE —ROOF HE ROOFr -- _- — OR AS 'K'-BRACING IN THE WALLS SHALL BE 2' x 2' PURL -IN x .093 WALL THICKNESS TUBE, AND SHALL BE CUT TO FIT SNUG, WITH NO PLAY OR SHIFT IN THE BRACING. D I 142;OI'AL ROOF S AC f I G DETAlFILE CO 5 E DETAIL S_AT RIGHT FOR CONNECTION SPECIFICATIONS 1=�o t55 9 �W Ll.� o 120 u— 8 o ® Lou) � e Lu iL 4 SEAM 5FLICE 5PECIFICATION3 a � S S +14 TEK SCREW � (TYPICAL) SAME AS 'A' BELOI JUST REVERSED 0 X � O O O _O 0 o O 1 _ 1® ® 1 o O O O o 3x3x.010H 11 0 0 O O: i ffl CORNER UPRIGHT ® r 0 1 O LU SPLICE PLATE MATERIAL •� SHALL BE 1/4' THICK (MIN.) AND BE EITHER 16063-T6 OR 06061-T6 ALLOY BEAM SPLICE DETAIL (2 x. 8 BEAMS AND LARGER) II A0 0 0 O O 0 0 1 0 1 O �® V14 TEK SCREW (TYPICAL) s DIAGONAL WALL BRACING (111/ 11 B AGIN ) DETAIL 2 x 3 x .010 ROOF �`j' � 2 x SMB SCREEN "_ -� PURLIN I � — ROOF BEAM 1LU a 4-INCH x 4-INCH x 1 Lu - f .010 PLATE, WITH (4) 012 TEKS IN THE 3 x 3,(3) 012 TEKS SPLICE PLATE MATERIAL, IN THE BOTTOM 1 IN SHALL BE 3/16' THICK (MIN.) x 2 AND (3) f12 TEK IN THE 2 x 2 BRACI AND BE EITHER 06063-T6 OR 06061-T6 ALLOY BEAM SPLICE DETAIL (2 x. I BEAMS AND SMALLER) dN JAI O� IlA TYP. ROOF U z 91 d SPLICE PLATE TOLERANCE NOTE: BEAM wlu — TYPICAL 3/16 OR 1/4' THICK SPLICE PLATI ALL SPLICE PLATES (ALUMINUM ALLOY 06063-T(o or 06061-T6) SHALL BE CUT TO BE «0.000 / -0,0625, AS INDICATED IN THE SCHIrMATIC DRAWING AT LEFT 3 x 3 '• W,.,... _ COLUMN 2x2x.093T DIAGONAL BP I x 2 BOTTOM SCREEN FRAI` -"--Ix205TOP --- 5CREEN_FRAME - �-2 x 2 x .OS3 TUBE DIAGONAL BRACE 2x3x.010CHAIR RAIL 2 x 2 x .053 TUBE - DIAGONAL BRACE DETAIL 11,411 (0051DE) (IN51DE) I x 2 OB BOTTOM SCREEN FRAME 3 W C UKNI:-.N )LUMN 2 x 2 x .093 TUBE DIAGONAL BRACE I x 2 BOTTOM SCREEN FRAME I -INCH x 3-INCH x .093 ANGLE, CUT 4- INCHES LONG, WITH (3) 012 TEK5 IN THE 3 x 3,(3) 012 TEKS IN THE BOTTOM I x 2 AND--(3) 012 TEK5 IN THE 2 x 2 BRACE 2 x SMB UPRIGHT well DETAIL II e' 2 x 2 x ,093 TUBE — DIAGONAL BRACE 2x3x.010 CHAIR RAIL 2 x 2 x .093 TUBE DIAGONAL BRACE 2 x 9 SM13 UPRIGHT - ftNIMUM SIZE) 2 x 2 x .093 TUBE - DIAGONAL BRACE 2 x 5 SMB UPRIGHT (MINIMUM SIZE) 2x3x,010 CHAIR RAIL 2 x 2 x .093 TUBE DIAGONAL BRACE 0 0 0 s 0 0 0 0 0 00 0 0 0 0 0 (OUTSIDE) 0 0 0 O 0 (IN51DE) t= U_ a O w m� L F- w >L M. uj 4-INCH x 10-INCH x O�-, -� ,010 PLATE, WITH (7) uj x 12 TEK5 IN THE 5MB '-- Lu UPRIGHT, (3) #12 TEKS IN THE CHAIR RAIL AND (3) �12 TEKS IN EACH 2 x 2 BRACE 2x3x.010 oILL CHAIR RAIL o _ ix a L& LU Za.L& �� a.co Lu .y9 3: � -7 I -INCH x 3-INCH x .093 ANGLE, CUT 4- INCHES LONG, WITH (3) #12 TEKS IN THE SMB UPRIGHT AND a x 2 TEKS IN THE 2 2 x 2 BRACE +� 2x3x.010 CHAIR RAIL I -INCH x 3-INCH x 00 3 ANGLE, CUT 4- INCHES LONG, WITH (3) 012 TEKS IN THE SMB UPRIGHT AND (3) 012 TEKS IN THE 2 x 2 BRACE NMI SCREEN ROOF ENGL05URE - TC - HOF STRUCTURE ATTACHMENT pETA I L DE51GN NOTE: THE 3-INCH LEG OF THE ANGLE SHALL BE PLACED AGAINST THE I x 2. THIS -ALLOWS --A -MIN -EDGE DISTANCE FOR THE FASTENERS (FROM THE EDGE OF THE ANGLE) OF ONE- INCH,. AND -MAINTAINS A SIX-INCH MIN. CENTER -TO -CENTER DISTANCE FOR THE MAX. SIZED CONCRETE ANCHORS (3/6" x 31/2') CAP (TYP) N05T C.B.S. WALL (TYP) TYP SCREEN ROOF BEAM I x 2 2'x3'x•125'ANGLE W/(4)012 TEKS, TYP. EACH SIDE OF BEAM FA5GIA REINFORCEMENT DE516N NOTE, ALL FASCIA BOARDS ON ANY EXISTING HOST 5TRUCTURE THAT WILL HAVE ANY PART OF THE PROPOSED SCREEN ENCLOSURE ATTACHED TO IT SHALL BE -REINFORCED, -BY= FLACING-ONE-(I) 1/4' x 4-LAG-5CREW INTO -THE -END. OF — EVERY TRUSS TAIL (WHERE THE PROPOSED SCREEN ENCLOSURE IS BEING INSTALLED). THESE TRUSS TAILS MUST BE PILOT DRILLED WITH A 5/32" DRILL BIT TO PREVENT SPLITTING THE END OF THE TRUSS TAIL5, IT SHALL BE THE REP60N5I5ILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THIS STEP IS COMPLETED, AS SPECIFIED, PRIOR TO ANY INSTALLATION' TAKING PLACE. FASTENER SHALL BE 1/4' x 3 1/2' PIED -HEAD ITW TAPCON FOR ALL 2' x 6' BEAMS AND SMALLER. FASTENERS SHALL BE 3/5' DIA. FOR 2' x 1' BEAMS AND LARGER (SEE DESIGN NOTE ABOVE REGARDING 3/8 FASTENER SPACING) WALL ATTACHMENT 10-INCH LONG 025 THICK) EXTRUDED- 'Z' GUTTER INSERT, TYP CENTERED ON EACH ROOF BEAM, WITH FOUR (4) #10 TEKS THRU TOP LIP OF GUTTER 1/4' x 21/4' LAGS, FOUR. (4) IN EACH 10-INCH INSERT AND AT 24' O.C. (MAX. N SPACING) IN THE REST OF THE GUTTER (PILOT - DRILL FASCIA W/ 5/32" e N BIT TO AVOID SPLITTING) I` H 5' STRUCTURAL - GUTTER (CONT.) FA6GIA REINFORCEMENT SPECIFICATIONS' 1/4' x 4' LAG SCREW, TO BE INSTALLED INTO THE END OE EVERY TRUSS TAIL WHERE A SCREEN ENCLOSURE .WILL BE ATTACHED. THE TRUSS TAIL SHALL BE PILOT- DRILLEb WITH A 5/32' DRILL BIT (TO PREVENT SPLITTING THE END OF THE TRUSS TAIL) SEE 'SNAP / LAP CONNECTION' NOTE ON SHEET I FOR 5PEC.'5 2 x 3 x .125 ANGLE CLIP (CUT 2' LONG) W/ 3-INCH LEG AGAINST I x 2. CLIP SHALL HAVE FOUR (4) 012 TEKS INTO SIDE OF ROOF BEAM AND TWO (2) 014 x 2' TEK5 (PER ANGLE CLIP) THRU GUTTER AND INTO 7' GUTTER INSERT (TYP. ONE ANGLE CLIP ON EACH SIDE OF EACH BEAM) �- TYP. 2 x SCREEN ROOF BEAM (MAY BE FLAT I x 2 SCREEN OR SLOPED) FRAME(TYP) FLAN VIEW IRuaS TAIL ( IT I-) 2 x FASCIA BOARD (TYP) NOTE: FASCIA ATTACHMENT RECUlR56 A 2 x FASCIA __BOARD_(MINIMUM). A 'I_x' FASCIA IS .ONLY-AIDEQUATr FOR THIS INSTALLATION WHEN THERE 15 A 2 x SUB - FASCIA BEHIND IT, IN THIS CASE, THE LAGS MUST PENETRATE THE SUB -FASCIA 111/2' (MIN. EMBEDMENT). IT SHALL BE THE RESPONSIBILITY OF THE SCREEN CONTRACTOR TO VERIFY THE- PRESENCE OF THIS SUB -FASCIA. CAP (TYP) 10-INCH LONG 025 THICK) EXTRUDED - 'Z' GUTTER INSERT, TYP CENTERED ON EACH ROOF BEAM, WITH FOUR (4) 010 TEKS THRU TOP LIP OF GUTTER 2 x HOUSE FASCIA (SEE FASCIA NOTE ABOVE) 114' x 21/4' LAGS, FOUR (4) - ---- IN EACH 10-INCH INSERT AND AT 24" O.C. (MAX. SPACING) IN THE REST OF THE GUTTER (PILOT FRILL FASCIA W/ 5/32' BIT TO AVOID SPLITTING) I x 2 x .0S3 ANGLE SPACER - (FOR ANGLED FASCIA 51D. ATTACHMENT), ATTACHED [J/ TWO (2) ROWS OF 010 TEKS (STAGGERED), EACH ROW AT 18' O.C. (MAX. SPACING) - - _ STRUCTURAL GUTTER CONN E C T ION --[DfT-A-1t-- T-A-1t- TYP SCREEN ROOF BEAM I x 2 2' x 2' x .125' ANGLE W/ (4)112 TEKS, TYP. EACH SIDE OF BEAM 1/4' x 2 1/2' LAG SCREW TYP. I EACH SIDE OF BEAM l2' x (o' BEAMS AND SMALLER) 3/6' x 2 1/2' LAC-, SCREW (2" x l' BEAMS AND LARGER) FA5GIA ATTAGH- TENT SEE SEE "SNAP / LAP CONNECTION' NOTE ON SHEET I FOR SPEC.'S '—U-CHANNEL CAP (TYP) I x 2 SCREEN FRAME(TYP) 5' STRUCTURAL GUTTER (CONT.) ZI SECTION VIEW TYP. 2 x SCREEN ROOF BEAM (MAY BE FLAT OR SLOPED) 2 x 3 x .125 ANGLE CLIP (CUT 2' LONG) W/ 3-INCH LEG AGAINST I x 2. CLIP SHALL HAVE FOUR (4) 012 TEKS INTO SIDE OF ROOF BEAM AND TWO (2)114 x 2' TEKS (PER ANGLE CLIP) THRU GUTTER AND INTO AV GUTTER INSERT (TYP. ONE ANGLE CLIP ON EACH SIDE OF EACH BEAM) —m _ _ g � co z z co m 0 o 0�,�• gemto 44 �! cn ZiEo.�R LUZ®-® OLub o � cn :E 0 �- o . a C N FRONT WALL 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT I x 2 05 BOTTOM FRAME AND ONE (1) 316' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR 2 3/4', MIN. EDGE (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) pISTANCE 3 x 3 x .010 FRONT WALL SIDE WALL - CORNER -UPRIGHT- -- -- - 010 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL I x 2 05 BOTTOM FRAME w z Lu NOTE 03, SHEET n) TO BE IS- INCHES, CENTER -TO -CENTER I x 3 05 SIDE -WALL CORNER UPRIGHT N ? MAX. SPACING FLAN VIEW MANSARD SCREEN ROOF 2 x 3 x .010 EVE RAIL, SEAM (BEYortp) TYP. (CONTINUOUS) 2 x 5 x 'Ia' ANGLE (2-INCHES LONG) WITH (2) 014 TEKS INTO TOP OF 2 x 3 EVE RAIL AND (2) 014 TEK5 INTO THE FRONT I x 2 OB TOP FRAME OF THE 3 x 3 H FRONT WALL CORNER UPRIGHT I x 3 013 SIDE -WALL CORNER UPRIGHT 010 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE 03, SHEET 02) TO 5E IS - INCHES, CENTER -TO -CENTER 3 x 3 x .010 FRONT WALL MAX. SPACING CORNER UPRIGHT 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR 2 3/4', MIN. EDGE (MIN. OF 4-INCH EMBEDMENT II DISTANCE INTO THE CONCRETE) 0 0 I . z �r I x 2 05 50TTOM FRAME ~ ELEVATION VIEW CORNER UPRIGHT DETAIL NOTE: THIS ATTACHMENT I x 2 0:8. SCREEN FRAME, DETAIL ALSO APPLIES TO TYf , 6ETWEEN UPRIGHTS A 2 x 2 SCREEN FRAME, OR AS UPRIGHTS AGAINST- W/ THE FASTENER BEING A WALL OR COLUMN 4' IN LENGTH, TO 1/4' DIA. x 31/4' TAPCON - MAINTAIN A 2' MIN: TO I3E PLACED AT NO MORE EMBED. THAN IS' O.C. (RE: GEN. N01TE_13) MIN. EMBEDMENT FOR CONC. / C15.6, / MASONRY ALL TAPCONS-SHAI -- 61RFACE BE 2' INTO CONCRETE. NOTE: ALL FASTENERS SPECIFIED IN 'COLUM-TO-FOUNDATION' DETAILS PERTAIN ONLY TO THE FASTENERS TO ESE PLACED ON EITHER SIDE OF COLUMNS. THIS DETAIL IS FOR ALL INTERMEDIATE FASTENERS FOR I x 2 SCREEN FRAME TO EITHER CONC. DECK OR C4.6. MASONRY WALL. BEAM 51ZE . 2x5-2x& 2x"1-2x8 2 x 9 2 x 10 NO, OF 014 TEK5 (PER 51DE) (2) 114 TEK5 (4) 014 TEK5 (5) #14 TEK5 l6) #14 TEKS '�'� 2 x SM5 SCREEN ROOF IBEAM 2 x 3 x .010 ROOF PURLIN 21ia' x 11/2' U-CHANNEL CLIP ATTACHED TO THE EVE RAIL WITH 61X e(b) 012 TEKS, AND (3) 2 x 3 x :010 ROOF PIJRLIN 012 TEK5 INTO EACH SIDE OF 2 x 3 x 010 EVE RAIL, ° THE 2 x 3 ROOF PURLIN (Td TYP. (CONTINUOUS) ° BE ATTACHED ON THE TOP ° END TO THE SCREEN ROOF — —1 2 x 5 x aka' ANGLE (2-INCHES BEAM IN THE SAME MANNER 2 x 5 x i'/a' ANGLE (2-INCHES n° I LONG) WITH (2) 014 TEKS INTO LONG) WITH (2) 014 TEKS INTO d 0 TOP OF 2 x 3 EVE RAIL AND TOP OF 2 x SMB f5EAM AND (2) "14 TEK5 INTO THE FRONT —2 x 4 x 110' ANGLE (2-INCHES (2) 014 TEKS INTO THE FRONT 0 0 1 OF THE 2 x 5MB SIDE WALL LONG) WITH (2)114 TEK5 INTO OF THE 2 x SMB, FRONT WALL UPRIGHT BOTTOM OFNT'HE 2 x 3 PURLIN UPRIGHT AND (2) 014 TEK5 INTO THE I x 2 dB TOP FRAME BACK OF THE 2 x SM5 SIDE I x 2 05TOP FRAME WALL UPRIGHT 010 x 2' 6M5 SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE 03, SHEET "2) TO BE IS - INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 5 51-115 UPRIGHT (MINIMUM SIZE FOR ANY UPRIGHT ON A SCREEN ROOF ENCLOSURE) i4' MIN. ED DISTANCE SEE 'MINIMUM FOOTER TABLES' ON SHEET 11 010 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL 2 x 3 x .010 CHAIR RAIL (TYP) NOTE 05, SHEET #2) TO BE 18- INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 412 TEK5 INTO THE UPRIGHT AND ONE (U 3/8' REP -HEAP 'TRU-BOLT' WEDGE ANCHOR, (MIN. OF 4-INGH EMBEDMENT INTO THE CONCRETE) / I x 2 OB BOTTOM F AME 2 x 5 5MB UPRIGHT (MINIMUM 51ZE FOR ANY UPRIGHT ON A SCREEN ROOF ENCLOSURE) 2V/4' MIN. EDGE DISTANCE I x 2 OB BOTTOM FRAME — SEE 'MINIMUM FOOTER TABLES' ON SHEET-0I 33/4' 3' I / MIN. MIN. - ---- SIDE WALL UPRIGHT P i keo9ci_.TT ALL SCREEN ROOF BEAM SHALL OVERLAP ON THE OUTER SIDE OF 15OTH 51DE5 OT THE UPRIGHT ITYP. EACH BEAM -TO -UPRIGHT CONNECTION) SEE TABLE ABOVE FOR NUMBER OF 014 TEKS, AS SPECIFIED RASED ON BEAM SIZE 2 x 3 x .010 CHAIR RAIL (TYP) 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 12 TEKS INTO THE UPRIGHT AND ONE lU 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) UPRIGHT DETAIL Cri go- 10 ZIVW LLJ z0- LL L13 L(a �0)ws w-LO 0 �— CL u Z �d d.7 f L