Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS� 1 Date: �1 Og Fee Due: Receipt# Permit # 0)903-- 0 3a St. Lucie County Building & Zoning 8Cq Y/�/� 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel.772-462-1553 St e� • �1°R�oP APPLICATION FOR ROOF PERMIT U�ie 004o lk SEE REVERSE SI FOR INSTRUCTIONS 1. Location/Site Address: SUt k1. 0 191 2. Parcel ID Number: QL%- - Office Use Only Section Township Range Map Page Zoning Land Use Initials 3. Description of Projector Work Activity: 7r&PY-O FF IS Ingle ��Qr 4. Total Roof Area (square feet): 11(20 5. Roof Pitch: 0 1 6. Type of Roof: Fiberglass Shingle ❑Barrel/Tile Ceramic ❑ Wood Shake Shingle ❑Tar & Gravel ❑Modified Bitumen ❑ Metal ❑ Other (specify) N.O.A — Product Approval required for All Types of Roofing Material ❑ All Commercial Roofing Requires Design by an Engineer or Architect (two Sets) 7. Owner Information 1 8. Contractor Info r ation Name: (Y11C AEL l tS ST O� r, �I�l 11�1 �s% FL Reg/Cert #: � (,r C l 32 1; 124 Address: Sl qfj ` ME� Oplq� County Cert#: Q g City: �bY o P1CrC� State: Business Name: �.A SnuoeOFX. , Zip: :649 qt]-- Phone: LJUn - 12'3(j Phone 4(, - LID qa Fax % g 39 7 9. Value of Construction: $ go Note: Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval OWNER'S AFFIDAvrr: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and m PRINT QUALIFIERS/OWNERS NAME / / SIGNATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF T%r1 I_�L I J O /�A ACKNOWLE ED BEFORE ME THIS ' DAY OF -,",a BY l ift �y 1i ,, WHO IS PERS ALLY KNOWN TO ME OR WHO HAS PRODUCED AS IDENTIFICATION. NOTARY PUBLIC -STATE OF FLORIDA '����_►F��E� KarelxS�� Nielsen SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY ,COII�II erXsn # Nielsen 4I TITLE: NOTARY PUBLIC COMMISSION NUMBER ]� S�I f u I1y1 Comm. Expires: 06/12/20 10 St. Lucie County Roof Permit Application rev. 7/18/05 dmg EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3187097 Oh` 'OK 2955 PAGE 973, Recorded 03/31/2l` Fiat 10:19 AM k - e 03/ 20,12000 13:02 17724000397 1111k N, 1tNl� fiVf�k l'+1'L41V'rl)t e KUr 1Y0111. L JA TAYLOR ROOrINC NOTICE OF COMMENCEMENT rAGC 03/04 S1_ 'rho pmkrit:nW Hereby.Ivcn nmice that ininm4mnrnl will hr natdr in rrnnin rr:d orntrny nnil in nretinlun'I• niiih rhvi r 717 Florida stututes tlu folh,wing inhmnation Is provided in the Nutim or commenacman z22`$'• 844 •oG�i3'A�O.3 1. DESCRIPTION OF PROPERTY ll egal description and street addreast TAX FOLIO NUMBER: SUBDIVISION IBLOCK— _TRACT LOT a ULUu UNIT 2.CENCRAI. DFACRIPTIONOF Inll'kuVt:y1 ...OWNER INFORNIAT10N1 b. Address i4S 1415jo [Z+ IP.►?! a, pinnu nitd adJr�.,. sf fs .:,.,rl_ I;tl„l..•IJ.. (:f...l.., ll...�• .,+....I_ 4. CONTRACTOR'S NA". AVDRES.4 AND PHONE NUMBER: a Interest in propcny,_014W6f_ S, SURETY'S NAME. ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7, Pcnon.t within the State orRoridu designuted by Owner upon whom notices ormher documents may be.drved as provided by Section 713.13 (I)ha) 7„ Florida Statules: NAM, ADDRESS AND PtR)NE NUMBER: d, [it uddititm to himself or henalG nwner drsignntr.% thr following to receive u copy of the Lienor'a Notice un provided in Section 713.1)1101. Plan Ida Smokes; NAMR, ADDRESS nND PN(XNE .%it;MR6Rt 9. Expimdnn date or notice of cnmmcncement Ohe cxpiratip,Ydate is 1 year from the dutc of recording unless a d1tyeront date is specified) 20_ •,,•• �w:o..:.,•^•,••,••:�•••,,•,_,••, ••••,,_,• •"•• L•d,•,r­ I".Ili ll.h. YYOIYf1,.1-1bu. 1,lu11Y1 •,••,^ n YUUN LnYINtL L1j GCS FOR IMPRO P 5 TO Ol1R PROPER A NOTICE OF COMMPNCFMBJJT MUST 9fi RF�Q$ 0 Ally) PUSTGD ON'1'HR JOB_Srf,G B • F „�J,RS,t.N$PEGI'IQN• 1F YOV INTENQ_IQ OR-- FlNAN[�pir [(1NCIIIT WRN VOUB .FN�PR OR AN nTTORNFV flf•P MFN[INO WQ,& OR RECORDNO YOUR NOT E OPCOMMF.N[CMt rjT ilgn6rc of Owner or Print Name and Provide Signatory's Tltle/OMce Owner's Authorized ORicur/Direct6r/PartnerlMnntlger State or Florida County or A l 1 1C.IE The rorcgning Instrument was acknowledged belorc nu this _Q_duy of %i41ti��i 2t1_Q�_, B y e� bECT14 !.l1�Si , ns �a1t JILF. P tNumo o(pemonl (Type of authorhy...e.g, Owner, officer, tnistee. attorney in fuel) (N7O1r of puny un ileh:df of whan inutn,menl was exceurod) Nrsonally Ka,,.,.t_ ur pm1duced the 11n1lowing type of ID: _ NOTA'LY' PUBLIC -STATE OF FLORII)A `- gFA S K�LELssaj Karen S. Nielsen (Printed Namc of Notary Puhlld (Signtuum nl'Nornry Publici t $ Cgminission # DD551441 Under penalties of perjury. I declare that I have rend the foregoing and thus the faces in It are true YhE {n1f lEflt+;vl( (15h(RU10 bcti'Xisection 92.521. Finrida Sruutcsl. Signnture(sl orOwnerfsl or Owner(.)' Authad7Ad On'IcerfDlrector/PartnerANanager who signed ahuvet By: Rn.UNNYYtmx.a0-1- I STATE OF FLORIDA ST. LUCIF STY THIS �(? FI TIF``TI AT HIS IS A TRtlF ..1Ii I!:r,.; i tl� Cs rr~ii ORIG Da Date: AG-5 AG-5 3501 AG-5 AG-5 99999 AG-5 AG-5 99999 AG-5 AG-5 ROW ROW ROW ROW AG-5 AG-5 99999 3795 u ,ZwV Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 hOn•//c41uiriarn nnv/ra Property Information Parcel # I2228-441-0001-000/8 00000001 Map # 22/27X Lot Size Subdivision Plat Book Plat Page Jurisdiction St.,Lucie County,:,OR Book 1253 OR Page 0620 Section 28 _ Township 35 Range 38 I Lot # Block DOR 6900 Flood Zone X, nimum Flood Elevation Flood Map Historic ❑ of Comments F7 # of Building Permits 13 # of Code Cases 0� # of Zoning Certificates 0� Ar Sewer NumbE Utility Type Utilitiy Numb( Sewer TypE I ;:� EETS AND BOUNDS LEGAL DESCRIPTION, Add Legal Description >> F-1 Legal Description Number Dir Street Name Suffix Unit 3795 SNEED RD Address 13795 SNEED RD- 11 City / State / Zip FORT PIERCE FL 34982, Zoning jAgricultural - 5 Future Land Use AG-5 Agriculture - 5 Site Plan Name PROPERTY OWNER INFORMATION Add Owner; >>; Michael West Name Michael West Phone # (772) 467-1230 Roberta West Address 1 3795 Sneed Rd Fax # ( ) - Address 2 ;ity / State / Zip I Fort Pierce FL 34945-4716 (COMMENTS Add Comment.>> Date Entered Reported By . Comment ADDITIONAL INFORMATION Status IMPACT FEES AND ZONING COMPLIANCE FEE NEEDS TO BEOPAID WHEN ZONING CERTIFICATE LETTER IS PICKED -UP. LAPyDETERMINED 5 ACRES SPLIT FROM NATURE'S KEEPEROPARENT PARCEL NEW #2228-441-0002-0005 CAN HAVE ANOAG EXEMPT MH PER RAY WAZNY & JULIA SHEWCHUK SEEOATTACHED LETTER FROM PROPERTY APPRAISERS JERRYOBUTLER GRANTING AG EXEMPTION FOR YEAR 2000 Open Building Permits Binder Building Permits Type Status Job Address 1443501 ZCB FIN 1443502 ZCB fin 20020098 EP Fin 20020169 MH Fin 20040501 EP Fin 99030006 EP Fin 99030007 EP Fin 99030506 VP Fin 99030507 BC Fin 3795 SNEED RD 3795 SNEED RD 3795 SNEED RD 3795 SNEED RD 3795 SNEED RD 3795 SNEED RD 3795 SNEED RD Open Code Enforcement Binde► ua r- Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce BUILDING PERMIT Page 1 Issued: 03/31/2008 Conf #; 768 Permit #: SLC- 0803-0323 Job Location: 3795 SNEED RD City: FORT PIERCE Permit Type: Roof Job Description: TEAR- OFF - (SHINGLE) RE- ROOF WITH FIBERGLASS SHINGLE 1700 SF 2/12P Subdiv: Lot: Block: Contractor TAYLOR, CHAD G Parcel: 2228-800-0003-000/3 J A TAYLOR ROOFING INC (772) 466-4040 302 MELTON DR FT PIERCE, FL 34982 Property Owner MICHAEL WEST (772) 467-1230 3795 SNEED RD FORT PIERCE, FL 34945-4716 Property Owner ROBERTA WEST (772) 467-1230 3795 SNEED RD FORT PIERCE, FL 34945-4716 Setbacks Left: Right: Number of Units: 1.00 Floors: 1 Minimum Floor Elevation: Job Value: $ 3,740.00 Front: Rear: Zoning: AG-5 Buildings: 1 Square Footage: 0.00. Flood Map: 150F Flood Zone: X ' Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6);months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. _ Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, Fl- 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stlucieco.gov/ce Date: 31 March 2008 Job Address: 3795 SNEED RD Received By: humphreya Paid With: CK Paid By: J.A. TAYLOR ROOFING INC Receipt #: 0000061836 'ermit Number: SLC- 0803-0323 Amount: $217.40 �redit Card Number: Check Number: 44666 Sign: 14 Florida Building Code On71,*— r�, Pagel of 2 t 2 $ k f K gx�'bAY 1Rf r�' 7L BCIS Home Log In Hot Topics j Submit Surcharge ` Stats & Facts Publications FBC Staff I BCIS Site Map ?Links I Search �' Product Approval C9R� $ € USER: Public User �.. Product Approval Menu > Product or Application Search > Application List > Application Detail W _, . �—Sqmol FL # FL8642 Application Type New �Fy Code Version 2004 gy; g Application Status Approved i k y7 &— ..ter Comments A' z ti "'M Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (419) 248-7060 darrel.higgs@owenscorning.com Authorized Signature Darrel Higgs darrel.higgs@owenscorning.com Technical Representative Address/Phone/Email Quality,. Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency Underwriters Laboratories Inc. Referenced Standard and Year (of Standard Year Standard) ASTM D3161 (modified to 110 mph) 1999 ASTM D3462 2001 UL 790 (Class A) 1997 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A 62 �22� Date Submitted 04/13/2007 Date Validated 04/13/2007 http://floridabuilding.org/pr/pr app dtl.aspx?toaram=wGEVXOwtDosLaKxWuLgWOvhCTk_ R/iinn07 Florida Building Code Or_,'�I� Page 2 of 2 Date Pending FBC Approval 04/16/2007 Date Approved 05/08/2007 mmary of Products FL # Model, Number or Name IlDescription 8642.1 _ > Duration Laminate Shingle = Limits of Use Certification Agency Certificate j Approved for use in HVHZ: No FL8642_RO_C_CAC_UL. Certification Letter 4-3- Approved for use outside HVHZ: Yes 07 Owens Corning Shingles.pdf Impact Resistant: N/A FL8642_RO_C_CAC_UL Certification, Files R2453 Design Pressure: N/A and R19380,.pdf Other: 1.) This Approval not for use in the Installation Instructions HVHZ. 2.) All FBC sections that apply to counties FL8642_RO_II_Install Documents Duration.pdf except Broward and Miami -Dade, must be FL8642_RO_II_Install Documents Starter followed. Shingle Roll.pdf Verified By: Underwriters Laboratories Inc. 8642:2 ` ' Duration Premium. Laminate Shingle Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL8642_R_0_C CAC UL Certification Letter 4-3- Approved for use outside HVHZ: Yes 07 Owens Corning Shingles.pdf Impact Resistant: N/A FL8642_RO_C_CAC _UL Certification, Files R2453 Design Pressure: N/A and R19380.pdf Other: 1.) This Approval not for use in the Installation Instructions HVHZ. 2.) All FBC sections that apply to counties FL8642 RO_II_Install Documents_ Duration.pdf except Broward and Miami -Dade, must be FL8642 RO II_ Install Documents Starter followed. Shingle Roll.pdf Verified By: Underwriters Laboratories Inc. 8642.3 JIStarter Shingle Roll Starter Roll Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL8642_RO_C_CAC_UL Certification, Files R2453 Approved for use outside HVHZ: Yes and --R19380,pdf Impact Resistant: N/A Installation Instructions Design Pressure: N/A FL8642 RO_II I.nstall Documents_Starter Other: 1.) This Approval not for use in the Shingle Roll.pdf HVHZ. 2.) All FBC sections that apply to counties Verified By: Underwriters Laboratories•Inc. except Broward and Miami -Dade, must be followed. Sack Next DCA Administration Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Suncom 277-1824, Fax (850) 414-8436 (D 2000-2005 The State of Florida. All rights reserved. Copyright and -Disclaimer Product Approval Accepts: Bobby a.•. ar=qpv-F http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsgKxWuLgWQyhGk... 8/ 13/2007 • � 9: v7 S: e i - s ••6 3 - �a 3Sky _ ,e..., . x .;s. a -.s,: � , a:, e'er§ :•.•a::nn...s, v'n.�`� a t: ys �` ._ �t s � eke r �2 4sf r x� i' ^-�k�as� °, Application instructions Before Installing this product, check local building codes for their roofing requirements. These shingles are designed for new or reroofing work over any properly built and supported wood roof deck having adequate nail holding capacity and a smooth surface. Check local building codes. Precautionary Note: The manufacturer will not be responsible for problems resulting from any deviation from the recommended application instructions and the following precautions: Roof Top Loading: Lay shingle bundles flat Do not bend over the ridge. Roof Deck: • 6" Maximum roof deck boards • Minimum W plywood • Minimum N" OSB Regardless of deck type used, the roofing installer must: I. Install the deck material in strict compliance with the deck manufacturer's instructions. 2. Prevent the deck from getting wet before, during and after installation. Ventilation: Must meet or exceed FHA Minimum Property Standards. Handling: Use extra care In handling shingles when the temperature is below 407. Storage: Store in a covered ventilated area at a maximum temperature of 110'F. Stack In a Oat fashion (maximum of 16 bundles high). Protect shingles from weather when stared at the lob site. Do not score near steam pipes, radiators, etc. Nails must be corrosion -resistant. It. or 12-gauge, with heads at least %' in diameter. Staples must be 16-gauge minimum, '%•" minimum crown width, and sufficient length to penetrate M into wood decking or through APA rated roof sheathing. Staples are to be corrosion -protected. All Fasteners must penetrate at least %" into the wood deck or completely through sheathing. Notice: Owens Corning recommends the use of nails as the preferred method of attaching shingles to wood decking or other mailable surface. Caution: Roof surface may be slippery, especially when wet or Icy. Use a fall protection system when installing. Wear rubbemaled shoes.Walk with care. Falling Hazard: Secure area below work and materials an roof. Unsecured materials may slide an roof. Place on level plane or secure to prevent slidfng.Wear a hard hat. Instrueelones de aplleael6n Antes de instalar este producto, consulte his c6digos de comtrucci6n locales pars Informarse sabre los requisitos de techado. Estas telas han sido disefladas parts la tonstrucci6n de techos nuevos o at arreglo de techos existentes sabre estructuras de madera constmidas correctamente y que poseen una capacidad adecuada de suleci6n de clavos y una superffcle Ilsa. Consulte Ins c6digos de construccl6n locales. Notts de precauet6n: El fabricante no sari responsable de problemas que sears consecuencia de no seguir exactamente In instmcciones de aplicacl6n recomendadas y las sigufentes precauclones: Carga sabre techo: Coloque los paquetn de telas de manera piana sabre el techo. No los doble sabre la cumbrem. Superficle del techo: • Tablas de superficie de techo de 6 pulg. minimo • % puig. como minimo de madera tercfada • %4 puig. como minima pan paneles de fibra orientada Cualquiera sea el tipo de superficie utilinda, el instalador debe: I. Instalar el material de la superficie siguiendu estriceamente las Instrucclones del fabricante de la superficle. 2. Evltar que la superfide se mole antes, durance y despues de la instalac16n. Ventilaci6n: Debe cumplir o exceder In normas minimas pars propledades establecidas par el FHA. Manipulacl6n: Tenga mucho cuidado at manipular las tejas cuando la temperatura sea Inferior a los 40°F. Almacenale: En un Area cubierta y ventilada a una temperatura no mayor de I IWE Apflar de manes piana (un mWmo de 16 paquetes de altura). Protela las telas del clima cuando las almacene en el lugar de trabajo. No las almacene cerca de tubedas de vapor, radladores, etc Los clavos deben ser Inoxidables, de calibre 11 6 12, con cabezas de par to menos %puig. de diimetro. Las limpas deben ser, como minima, de calibre 16, con un.ancho de corona de at menos'%• pulg. y una longitud suficiente pan penetnr'/, pulg. en la superficie de madera o a craves de un revesdmiento de techo que cumpla con In normas APA. Las grapas deben ser Inoxidables. Todos los suletadores deben penetrar al menos''/, pulg. en la superficie de madera o atravesar completamente en los recubrimientos de madera terclada. Avlso: Owens Coming recomienda el use the clavos como m6todo preferido Para fljar tejas a superfscies de madera u otras superficles aptas para clavos. El Culdado: El techo puede estar resbaloso, especialmente cuando esti majado o helado. Utilfce on sistema de protec. cldn contra caidas durante la Instalacion. Use rapatas de hule. Camino con cuidado. Peligra de calda de objetos: Par favor asegure A area que se encuentra debalo de la zona de trabalo y amarre los materiales at techo. Los materiales que no est6n sujetos pueden resbalarse del techo. Cal6quelas en un lugar queno tenga pendfente, o suj6telos para prevenlr que se resbalen. Use un casco reshtente. NMI w:,;_'ram zas` i:; ,.j� s s x,-x;?' { tt .... ... -....:. .. ..t� 1 k x "Tt.::. .,v ki;x, y,_. •.., _. .. .,,;.awu-n.�"..: '::. P ,.:.,.,, i�i.. , `,x .. Specialty Eave Flashing: Sp fatty Eeve Flashing ' Rove tlmlento especial WeatherLock•Underlayment Revestimientuespecialparealere paraateral or equivalent eave and flashing u.a s•u:+,s rn,,.,.yw,.e membrane applied to a point at a. ua°•°..°"•'o-a,.ai° least 24" beyond interior wall line. See manufacturer's installation instructions. See Fig. I. 2 Underlayment: Standard Slope (4" in IT' or more) Application of underlayment, metal drip edges and ewe flashing See Fig. 2. Low Slope (2" in 12" to less than 4" in 12") Application of underlayment and metal drip edges: See Fig. 2A 3 Chalk Linest To aid In shingle alignment, it Is recommended that chalk lines be snapped on the exposed surface of the underlayment prior to shingle application. See Fig. 3. irN:,d4,.m� bprb W.1 M, unuensyment manoaro mope Pendfente .scandal del fmparmeabilizante smpa s•m hr o,.ppa v.,,mm.,aap°to.am upmo- Pao sw.rvawee rp°a. Fig, 2r1 Underlayment Low Slope Pendiente bale del impermeabilizante PImG•nrla M]t, lu•th•n •-N Ir' pJp. �a rap,:y,n.n. aae, e• apwo-. ae• opals. W wa.,,,p• orb a4•el•- -w..a.a..r ipiw•nn:t•a• ••°ap,ds• l,pr4p '. t9 �bron a ,� rips a 4n,i ip'uq mya e J Lineas de tine Membrana autaidhesiva WeatherLock' o membinna equivalente pare alero y hordes aplicada an un Punta al menos 24 pulg. mis alli de la linea de la pared Interior. Consulte las fnstruccfones de Instalacibn del fabricante. Consulte to Fig. I. 2 impermeabilizante: Pendfente estindar (4 puig. cad. 12 puig. a ntAs) Aplicaci6n de impermeabilizante, bordes de goteo metilicos y revesdmiento del alero: Consuhe la Fig 2. Pendfente baia (2 puig. en 12 puig. a menos de 4 pulg. etc 12 pulg.) Aplicaci6n de impermeabilizante y bordes de goteo metilicos: Consulte la Fig. 1A. 3 Lineas de tiza: Para facilltar la alinead6n de In telas, se rect,mlenda hater marcas de tiza (udiizando sops Inhpregnadzs en tints) sabre a su I perficie expuesta del impermeabilizante antes de colocar In telas. C.—he la Fig. 3. 1117 ; ,r � `1 ,M� ;... uv . �K. .. ... ..#:. .:...d..._.A� ,.s..n:#S'.F�.F�t.I✓X<.x, ...Kaki... .N.S, w.. 4 Shingle Fastening: Standard Fastening Pattern Fasteners must be placed In the SureNail* fastening area. See Fig. 4. Six Nail Fastening Pattern For 6 nail fastening pattern. See Fig. 4. Mansard or Steep Slope Fastening Pattern Fasten between SureNail area and top of cut out See Fig. 4A. REQUIRED: For slopes exceeding 60 degrees or 21 inches per foot, use six fasteners and four spots of asphalt plastic cement per shingle. Apply immediately; one I"diameter spot of asphalt plastic cement under each shingle tab. Center asphalt roof cement 2"up from bottom edge of shingle tab. Roof Cement where required must meet ASTM D-4586 Type I or II (Asbestos Free). I Standard Fastening Pattem �ig. Esquarms des fljad6n eaNnelar 4ndh— E—4d— a.�wPeed......ue er ..z s "e✓ a, .r n we,—. ne, sx•ry.... r.P4a d.o+�.de. a.r en•w.a.mowse. 14NSix Nail Fastening Pattern 11 Esquema de Ajeudn de seis dares ...Am Eq & ad m. �A- VNi' r e, E— ir�. ME- 6%pO}4.q).ri#� PApuy 6.ryod:Mi Mansard or Steep Slope Fasteningg pattern Espena do fdadinpnt mareardas a p2entes tgudas sir [y.w n.wrE e..v.rwn 15 Shingle Applications These shingles are applied with a 6'/" offset. with W." exposure, over prepared roof deck starting at the bottom of the roof and working across and up. This will blend shingles from one bundle into the next and minimize any normal shade variation. Application with offsets of 4" or 5" are also acceptable. Caution must be exercised to assure that end joints are no closer than 2" from fastener in the shingle below and that side laps are no less than 4" In succeeding courses. Refer to course application steps for specific Instructions. (continued on next page) 4 Fllacl6n de toles: Esquema de Rlacl6n estindar Los suletadoresse deben colocar an el Area de suleci6n SureNail! Camulte Is Fig. 4. Esquema de BJacl6n de sets clavos Para un esquema de filaci6n de 6 clavos. Consuhe to Fig. 4. Esquema de flacl6n en pendientes pronunciadas o mansardas Filar entre el Area SureNail y la parts superior del recorte. Consuhe to Fig. 45, REQUISITOS: Para pendfentes de mis de 60 grados o 21 pulg. par pie, utilice seis suletadores y cuatro pequenas cantidades de cemento plistico asfaltado par tela. Inmedlatamente, aplique una pequena cantidad de cemento plistico asfahado de I pulg. de diimetro debalo de cads leng0eta de In tejas. Aseg4rese de que el cemento plistico asfaltado esc6 centrado 2 pulg. par encima del borde inferior de In iengiieta de In tela. Cuando sea necesario utilizar cemento para techos, Este debe cumplir con la norma ASTM D-4586 Tipo 16 II (sin asbestos). SAplicaci6n de las telass Etas tejas se aplican con un desplazamiento de Wii pulg., con una superficie expuesta de 5'/ pulg., sabre estructura base de techas preparadas. La colocaci6n comierin par In pane Inferior del cecho y se realiza en forma transversal hacia arriba. De esta manem, In tejas de un paquete se mezdan can las del siguiente y se reducen al mtnimo In variaclones normales de tonalidad. Tambldn se pueden aplicar tejas con un desplazamiento de 4 6 5 pulg. Asegurese de que In uniones de los extremos no se encuentren a menos de 2 puig. del suietador de la tela que se encuentm mAs abajo y que Us superposiciones laterales no sewn de menos de 4 puig. an In hilera siguientas. Consuhe los pasos de aplicacl6n de hileras pars ver In instrucciones especfficas. (continua en In pigina siguiente) SShingle Application (cont.): Starter Course: Use starter roll or trim We" from the starter course shingle. Trim 6h" off the rake of the starter course shingle and flush with the drip edge along the rake and eaves edge, and continue across the roof. Use 5 fasteners for each shingle, placed 2" to 3" up from eaves edge. See Fig. S. (If no drip edge Is used, shingles must extend a minimum of and no more than 1" from rake and eaves edge.) First Course: Apply first course starting with the full shingle even with the starter course. See Fig. 5A Fasten securely according to fastening instructions. See Fig. 4. Second Course: Remove 6i/" from the left end of this shingle and apply the remaining piece over and above the first course shingle and flush with edge of the first course with 5''/e" exposure. See Fig. 58. Fasten securely according to fastening Instructions. See Fig. 4. Third Course: Remove 13" from the left end of this shingle and apply the remaining piece over and above the second course shingle flush with edge of the second course with 5'/r" exposure. See Fig. 5C Fasten securely according to fastening instructions. See Fig. 4. (continued on next page) 9 Shingle Application . 5 pficad6n de texas C ApUcaet6n de las telas (coat.): a BMetouw Hilera InIcIal: 11°'• Utilice un rollo de Inicio o cone a 5% pulg. de 6 teia de la h0em Initial, _ de manera que el sellador esc6 alineado con el borde del alero. Corte 6yi pulg. er. up desde fa viga inclinada en la teja de la sr„sdi•:`M' trr hilera initial y extienda. Mn a0A de la '•., ; viga inclinada y el borde del alero, y rdmsa• continue a to ancho del techo. Udlice a bu�ay.m '.:.n•., e,"14,b,y, 5 sujetadores pars cads teia, colocados a um distancia de entre 2 y 3pulg. del horde del alem. Comuhe to Fig. S. (Si utilizes un borde de got". h', ' Shingle Appfication -Ig. 5A deben extenderse un minim plicacibn de resins '/, pulg. y un mAximo de 1 I rinse... de Is viga indinada y el borae - - rYax. m- del alero.) v Primers hilera: M... Coloque Is primers hilera come.tzando con la reja cortada alineada con la .,.°i°s,.d'. "� �,• hilera Initial. Consuhe to Fig. SA Sulece flrmemente de acuerdo con In instmociones de suleci6n. Consuhe la Fig. 4. Fig. 5B Aplieged6nnddee 'telas dpund� eaw4 N� - gn a.s.tq — �.m� ,s sxw4d•w,aea. Fig. 5C ShingleApplication lieae76n de reins nse toe» rw.r.NF..M'• yi: Segunda hilera: Quite 6''/a pulg. del borde izquierdo de esta teia y aplique la pieza restante sabre y per encima de la teia de la primers hilera y al ras del borde de la primers hilera, can 5% pulg. de exposici6n. Consuhe to Fig. 58. Suiete firmemente de acuerdo con las instruccfones de suieci6n. Consuhe to Fig. 4. Tercera hilera Quite 13 puig. del borde izquierdo de esta tela y aplique la pieza restante sabre y per encima de la teia de la Segunda hilera y all ras del bar'A la Segunda hilera, con 5'/. pulg,� 1 exposici6n. Consuhe la Fig. 5C Sujete firmemente de acuerdo con In instrucciones de sujeci6n. Consuhe la Fig. 4. (continua en la pAgina siguiente) SShingle Application (cant.): Fourth Course: Remove 191/z" from the left end of this shingle and apply the remaining piece over and above the third course shingle and flush with edge of the third course with 5s/s" exposure. See Fig. SD. Fasten securely according to fastening instructions. See Fig. 4. Fifth Course: Remove 26" from the left end of this shingle and apply the remaining piece over and above the fourth course shingle and Rush with edge of the fourth course with W exposure. See Fig. SE Fasten securely according to fastening Instructions. See Fig. 4. Sixth Course: Remove 32A" from the left end of this shingle and apply the remaining piece over and above the fifth course shingle and Rush with edge of the fifth course with SY," exposure. See Fig. SF. Fasten securely according to fastening Instructions. See Fig. 4. Succeeding Courses: For succeeding courses, repeat first through sixth course. See Fig. 5G. 9SD Is Ion t :! Apficad6n de tejn omataw. anmyeatppr:aoon Aph"of6a do to/as r C— o,a"u aao rm„tr�m,:.err. s..v raPY a11s11fRiva. 5FhingbAppication ApSlleadbn de cafes 5GShingle Application Aplicaddin do teiss SApncaci6n de las telas (tout.): Cuarta hilera: Quite IM pulg. del borde izquierdo de esta tela y aplique Is plaza resante sabre y par encima de la teia de la tercera hilera y al ras del borde de Is tercem hilem, con 5% pulg. de exposic16n. Consuhe la Fig. SD. Suiete firmemente de acuerdo can las instrucciones de suleci6n. Consuhe to Fig. 4. Quinta hilera: Quite 26 pulg, del borde izquierdo de esta teja y aplique la pieta resante sabre y par encima de la teia de la cuara hllera y al rss del borde de Fa tuara hilem, con 5% pulg. de exposici6n. Consuhe to Fig. 5E Sulete firmemente de acuerdo con las insuticciones de sujec16n. Consuhe to Fig. 4. Sesta hilem Quite 32% puig. del borde Izquierdo de esta tela y aplique la pies resante sabre y par encima de la teia de la quina hilera y al ras del borde de la quina hilera, con St/ pulg. de exposici6n. Consuhe to Fig. SF. Sujete firmemente de acuerdo con las Inswcciones de suleci6n. Consuhe to Fig. 4. H[leras siguientes: Pam In hilems sigulentes, repita los pasos que se indican desde Is primera hasa la sexta hilera. Consuhe la Fig. SG. 6 VaHey Construction: Flgt C Closed -Cut Valley Construction Construeel6n del canal: Closed -Cut Valley See Fig. 6. f t, V Cons&ucddn can anal de cone cerrado A closed -cut valley can be used as an alternative and is applied as follows: Lay a 36"-wide valley liner of self - adhered membrane underlayment or equivalent. A 36"--wide minimum SNb. smooth surface roll roofing can also be used as a valley liner. Lay all shingles on one side of valley and across center line of valley a minimum of 12". fasten a minimum of 6" away from center line on each side of valley. Strike a chalk line 2" from the center line of the unshingled side. Apply shingles on the unshingled side up to the chalk line and trim, taking care not to cut the underlying shingles. Clip upper corners of these shingles. cement and fasten. Both woven and meal valleys are acceptable alternatives. 7 Step Flashing: Use 10" x 7" corrosion -resistant metal where roof planes butt against vertical sfdewalls or chimneys. See Fig. 7. 8 Hip & Ridge Application: Use High Ridge Hip & Ridge shingles. Follow application instructions as printed on the High Ridge Hip & Ridge canon. See Fig. 8. ° tf °��®01 Vi4•°�°�°'°�r4` 7 Step Flashing Escdonedo Canal can torte cerrado Consuhe to Fig. 6. Como alternativa, se puede udlizar una limahoya con canal cermdo qua se aplica de la siguiente manera: Coloque un revestimiento de limahoya de impermeabila,ante de membmna autoadhesiva o equivalente de 36 pulg. de ancho. Para revestir la gmahoya, ambi6n se puede utilizar un rollo de techado de superficie lisa de 36 puig. de ancho y un minima the 50 libras. Coloque todas In telas sabre r-�,'� del canal y a trav6s de h Iinea del canal al menos 12 pulg. Suj(: un minimo de 6 pulg. desde la Ifnea- central a cada lado del canal. Marque una Iinea de tita a 2 pulg. de la Iinea central del [ado que no tiene teias. Coloque In tefas del lado que no tiene telas hasa la Iinea do tiza y recarte, con cuidado de no cortar In telas que se encuentran debala. Una los extremos superiares de can telas, coloque cemento y sujete. Se pueden utilizar canales de teiido o metal. 7 Revestlmineto escalonado: Utilice metal resistente a la corrosion de 10 x 7 pulg. en los puntos en los que los pianos del [echo se unan a las paredes laterales verticales o a chimeneas. Consufte to Fig. 7, FigUO Hip& Ridge Application Coloeaet6n de eaballetes y r Prepuaddndefuteiupmu6a8nesycumbrms 8 eumbreras: Utilice telas para lima tesa y cumbrem. o:.«a.s•.r m.Mnau,:wm Slga In instrucciones de colocac16n del envoltario. Consuhe to Fig. 8. For more information on Owens Corning roofing products, or any }of our wide .range oaf building products and systeirr; ,'Jt"s`e:asy t.o reach us;-. 1-800-`GET-PINK" '( www.owen'scornirig_,co:m OWENS CORNING ROOFING AND ASPHALT, LLC ONE OWENS CORNING PARKWAY v 'a TOLEDO,OHIO, USA 43659 r-0- a 1-$00-,GET-PINK" INKWAMIKS'FOR LING" . www:Owenscorning,com \ Pub. No. 10003278. Printed in U.S-A. March 2007. THE PINK PANTHER" & ^ J1 01:964-2007Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved The color PINKJs a registered trademark of Owens Corning. ©2007 Owens Corning. • Florida Building Code Online Pagel of 2 i , � a �:. •� @, f f 7 Y � ?` � k is 'i BCIS Home € Log In : Hot Topics Submit Surcharge . Stats & Facts 011110-- Product Approval USER: Public User k Publications FBC Staff BCIS Site Map Links Search^; Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type MR Spa' Code Version x x; Application Status Comments # Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Evaluation Entity Quality Assurance Entity Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the F1 5 311 FL3664-RI Revision 2004 Approved TAMKO Building Products, Inc. PO Box 1404 Joplin, MO 64802 (800) 641-4691 ext 2394 fred_oconnor@tamko.com Frederick O'Connor fred_oconnor@tamko.com Frederick J. O'Connor PO Box 1404 Joplin, MO 64802 (800)641-4691 fred_oconnor@tamko.com Roofing Underlayments Evaluation Report from a Product Evaluation Entity ICC Evaluation Service, Inc. Underwriters Laboratories Inc. PRI Asphalt Technologies, Inc. http://floridabuilding.org/pr/pr app dtl.aspx 11/9/2007 Florida Building Code Online Page 2 of 2 Product Approval Method Method 2 Option A Date Submitted 06/07/2005 Date Validated 06/08/2005 Date Pending FBC Approval 06/20/2005 Date Approved 07/01/2005 _... __.... __..... _............. ......... ......... _..... _..._....__....._.............. iSummary of Products .--....._.._...__.............. ........._.........._..........--...... -......_._.... _.......... _....... _.... ._..._.....---.............................. ._...._.........._._........... _..... _........... _.......... ..... ......... .... : FL IlModel, Number or Name IDescription 3664.1 Underlayment 7Kself-adhering r rubberized asphalt sheet ::I membrane. Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Evaluation Reports Impact Resistant: PTID_3664_R1_T_1252.pdf Design Pressure: +/- Other: Membrane should not be applied to damp, frosty or contaminated surfaces. Membrane should not come into contact with products containing coal -tar pitch. Not.approved for use in High Velocity Hurricane Zones. Back Next DCA Administration jl Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Suncom 277-1824, fax (850) 414-8436 © 2000-2005 The State of Florida. All rights reserved. Copyright.and Disclaimer Product Approval Accepts: Bobby http://floridabuilding.org/pr/pr app dtl.aspx 11/9/2007 j 1 , ESR-1252 , S R E P O R TT'" Reissued April 1, 2005 This report is subject to re-examination in two years. ICC Evaluation Service, Inc. Business/Regional Office ■ 5360 Workman Mill Road, Whittier, California 90601 a (562) 699-0543 Regional Office ■ 900 Montclair Road, Suite A, Birmingham, Alabama 35213 ■ (205) 599-9800 www.icc-es.org Regional Office a 4051 West Flossmoor Road, Country Club Hills, Illinois 60478 a (708) 799-2305 DIVISION: 07—THERMAL AND MOISTURE PROTECTION Section: 07305—Roofing Felt and Underlayment REPORT HOLDER: TAMKO ROOFING PRODUCTS, INC. PO BOX 1404 JOPLIN, MISSOURI 64802 (417)624-6644 EVALUATION SUBJECT: MOISTURE GUARD PLUS® ICE AND RAIN PROTECTIVE UNDERLAYMENT AND TW UNDERLAYMENT 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2003 International Building Code° (IBC) ■ 2003 International Residential Code® (IRC) ■ BOCA' National Building Codell 999 (BNBC) ■ 1999 Standard Building Code° (SBC) ■ 1997 Uniform Building Code TM (UBC) Properties evaluated: ■ Severe climate underlayment ■ Ice barrier 2.0 USES Moisture Guard Plus° and TW Underlayments are self - adhering membranes used as an alternate to the ice barrier specified in Chapter 15 of the IBC, BNBC, and SBC, and Chapter 9 of the IRC. Additionally, the membranes are used as an alternate to the underlayment in severe climate areas specified in Tables 15-B-1, 15-B-2, 15-D-1 and 15-D-2 of the UBC. 3.0 DESCRIPTION 3.1 Moisture Guard Plus®: A nominal60-mil-thick [0.060 inch (1.52 mm)], fiberglass -mat - reinforced, SIBS modified bitumen membrane with mineral fines on the top surface. The membrane is backed with a release film, to protect the membrane adhesive. The membrane is black in color and is produced in rolls 393/e inches wide (1000 mm) and 30 feet 6 inches (9296 mm), 45 feet 8 inches (13 919 mm), or 61 feet long (18 593 mm). 3.2 TW Underlayment: A nominal 40-mil-thick [0.040 inch (1.02 mm)], unreinforced asphalt membrane with a polymeric film on the top surface. The membrane is backed with a release film, to protect the membrane adhesive. The membrane is black in color and is produced in rolls 39% inches wide (1000 mm) by 61 feet long (18 593 mm). 4.0 INSTALLATION Installation of TAMKO Moisture Guard Plus° and TW Underlayments membranes shall comply with this report and the manufacturer's published installation instructions. The installation instructions shall be available at the jobsite at all times during installation. Prior to application of the membrane, the deck surface shall be free of frost, dust and dirt, loose nails, and other protrusions. Damaged sheathing shall be replaced. Installation is limited to plywood substrates. The membrane is to be applied only when the ambient air and substrate temperatures are above 35°F (1.7°C). The membranes are cut into 10- to 15-foot (3048 to 4572 mm) lengths and rerolled. The release paper is peeled back approximately 1 to 2 feet (305 to 610 mm) and the membrane aligned with the lower edge of the roof and set in place. The remainder of the membrane is applied directly to the roof deck by removing the film and firmly pressing the membrane into place. The end seams shall be overlapped a minimum of 6 inches (152 mm). Edge seams shall be overlapped 3'/, inches (89 mm) for Moisture Guard Plus® and 4 inches (102 mm) for TW Moisture Guard'. The subsequent courses of membrane are applied parallel to the eave, from the lower edge of the roof upwards in a shingle -lap manner. The membrane shall be installed in sufficient courses to extend up the roof the minimum distance prescribed by Chapter 15 of the applicable code (Chapter9 in the case of the IRC) beyond the interior of the exterior wall. If the membrane becomes misaligned, the roll is to be cut and restarted. The membrane is pressed firmly into place, from the center to edge. After application, the membrane shall be inspected, and any defects repaired. "Fish mouths" are slit, pressed flat, and covered with a patch of membrane of sufficient width and length to overlap each side and end of the slit a minimum of 3 inches (76 mm). Flashing around protrusions or metal drip edges shall be over the membrane, to prevent water backup. Installation of the roof covering can proceed immediately following application of the membrane. The membrane should be covered by an approved roof covering as soon as possible. For reroofing application, the same procedures apply after removal of the existing roof covering and roofing felts to expose the roof deck. L'S REPORTS" v to be construed as an endorsement q%the subject nfthe repory or it recounnendation•Jor its nse. There is no w•arranfi by 1CC Evahration Service, hrc, eapres's or implied, as to anv finding or other matter in this report, or as m unv product covered ht• the report. . ae....tL,arnp ramu:r anrmwwr, Copyright © 2005 Page 1 of 2 Page 2 of 2 �� ESR-1252 5.0 CONDITIONS OF USE The TAMKO Moisture Guard Plus° and TW Underlayments membranes described in this report comply with, or are suitable alternates to what is specified in, those codes specifically listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation shall comply with this report and the manufacturers published installation instructions. 5.2 Installation shall be limited to use on plywood substrates on structures located in areas where nonclassified (nonrated in the UBC) roof coverings are permitted. Where classified (rated) roof coverings are required, substantiating data shall be provided to the code official for approval. 5.3 Installation shall be limited to roofs with a slope of 2:12 (16.67%) or greater. 5.4 Installation shall be limited to use with roof coverings that do not involve hot asphalt or coal -tar pitch. 5.5 Installation shall be limited to use with roof coverings that are mechanically fastened through the underlayment to the sheathing or rafters. 5.6 Installation shall be limited to roofs with ventilated attic spaces. 5.7 The membrane shall be installed only when the ambient air and substrate temperatures are above 35°F (1.7°C). 5.8 The membranes are manufactured at the TAMKO Roofing Products plants located in Joplin, Missouri, and Columbus, Kansas, undera quality control program with inspections provided by Underwriters Laboratories Inc. (AA-668). 6.0 EVIDENCE SUBMITTED 6.1 Manufacturer's descriptive literature and published installation instructions. 6.2 Data in accordance with the ICC-ES Acceptance Criteria for Roof Underlayment for Use in Severe Climate Areas (AC48), dated January 2000 (editorially revised January 2005). 6.3 Data in accordance with the ICC-ES Acceptance Criteria for Roof Underlayments (AC188), dated February 2003 (editorially revised January 2005). 6.4 A quality control manual. 7.0 IDENTIFICATION The TAMKO Moisture Guard Plus® and TW Underlayments membranes described in this report shall be identified by a label, on the container of each roll of membrane, bearing the TAMKO Roofing Products name, the product name, the manufacturing location, the evaluation report number (ESR- 1252) and the name and logo of the inspection agency (Underwriters Laboratories Inc.).