HomeMy WebLinkAboutSUBMITTED PAPERSDate:. 131Fee Due: Receipt# I Permit #
St. Lucie County Building & Zoning �
2300 Virginia Avenue Ft. Pierce, FL 34982-5652 �qn/N
Tel. 772-462-1553 Ev
� c0
APPLICATION FOR ROOF �t <<lCi
PERMIT unty
SEE REVER,� SIDE FOR INSTRUCTIONS '
1. Location/Site Address: � � U 1sf:I tsw n -
2. Parcel ID Number: Q!A'A'X•31!. (�-CM-_I
Office Use
Only
Section
Township
Range
Map Page
Zoning
Land Use
Initials
3. Description of Projector Work Activity:'I EIR f F, veg'ezF' �J. T� fj 1�J �.•�
4. Total Roof Area (square feet): I'ZiM 5. Roof Pitch: Fug-r
6. Type of Roof:
FA I
❑ Fiberglass Shingle
❑ Tar & Gravel
Other (specify)
❑]Barrel/Tile Ceramic ❑ Wood Shake Shingle
L�IModified Bitumen ❑ Metal
N.O.A — Product Approval required for All Types of Roofing Material
❑ All Commercial Roofing Requires Design by an Engineer or Architect (two Sets)
7. Owner Information 8. Contractor Information
Name:-ftigTH A L.F— M 1 U, FL Reg/Cert #: CC, C / 3 25 %.W
Address: 4_511 ISU nl RISE 411 Vd • County Cert#:
City: 'Fps(-} Plep_CE State: 1=(r. Business Name: .�• �_mLa, kort al
Zip: Phone: ,0 4 Phone Fax L la- y 3 97
9. Value of Construction: $,
Note: Dry -in and Final Inspection Required.
Additional inspection may be required per Product Approval
OWNERS AFFIDAVIT: I certify that all of the information contained in this application is co eet tta d at work will be done
in compliance with all applicable laws regulating construction and in .
PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER
STATE OF FLORIDA, COUNTY OF �' t- LU(' I ACKNOWLE GED BEFORE ME THIS ,26'_ DAY OF
�I , YY OAdBY l=. MZ� WHO IS PERSO LLY KNOWN TO ME OR WHO HAS PRODUCED
AS IDENTIFICATION. NOTARY PUBLIC -STATE OF FLORIDA
& Karen(s'81) Nielsen
5IONATUREOFNOTM TYPE OR PRINT NAME OF NOTARY4$
T 5 qq' Commission # DD551441
TITLE: NOTARY PUBLIC COMMISSION NUMBER n 51 my COmm. Expires: 06/12/2010
St. Lucie County Roof Permit Application rev. 7/18/05 ding
EDWIN M. FRY, Jr. -CLERK OF THE CIiCUIT COURT - SAINT LUCIE COUNTY
FILE # 3184950 C`')OK 2953 PAGE 1328, Recorded 03/25/r- ':) at 12:46 PM
-�-LrI;N I<I�f'rlRlll V(i I<I': fr�nV Ir)
NOTICE OF COMMENCEMENT
4S V,
'bite undersigned hereby gi%en notice that improvement will be made to certain real property, and in accordance with Chapter 713,
Florida sunutes the following inlbnnution is provided in the Notice of commencemen:2435 701 W �/aMO.
/t O.
I. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER: ��
SUBDIVISION BLOCK TRACT LOT BLDG UNIT
33_3S S/e 6042 AM of IV J-r 61WRISE 13V AA N W OE SW yy OF SE f 6' DEG
2. GENERAL DESCRIPTION OF IMPROVEMENT: -W Mid w AIA W A* 91 6 Unl. a w-Ytl
3.OWNER INFORMATION: a.Namc��,QMOL I ErA&E
b. Address A4311 _< Utije1S& 61VA, VtJ J6C= t_F_ 1#97'>— interest in property nl'
d. Name and address or fee simple titleholder (ifother than owner)
4. CONTRACTOR'S NAME., ADDRESS AND PHONE. NUMBER: —7iZ- gtct,- go V6
5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT:
6. LENDER'S NAME, ADDRESS AND PHONE NUMBER:
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13 (1)(n) 7., Florida Statutes:
NAME, ADDRESS AND PHONE NU}IBER:
S. In addition to himsel for herself. Owner designates the following to receive a copy of the Lienor's Notice as provided in Section
713.13 (1)(b). Florida Statutes:
NAME. ADDRESS AND PHONE. NUMBER:
9. Expiration date of notice orcommencement (the expiroiol -date is I year from the dale of recording unless a different date is
specified) _, 20_
Signature or Owner or
Owner's Authorized OlTtcer/Director/PartnedNlonager
,��7ufJ IRLF/Yl IIPE
Print Name and Provide Signatory's Tille/Orfice
State of Florida
County or s f i4 o,
The foregoing instrument
nns ruument�wa% acknowledged before me this day of _ mA�R .20 QA
4.
(Name of person) (Type of authority,.. g. Ow— officer. trustee, attorney in fact)
For
(None of party on behalf of whom instrument was executed) Personally Known_ or produced the following type of ID: _
NOTARYPUBaren S. OF Nielsen
•i
9rj3�ti1 S.l�rEcSEnI Karen S. Nielsen
(Printed Name of Notary Public) Signature orNotary ublicl OCommission #DD551441
My CODIm, Expires: 015/12/2010
Under penalties of perjury. I declare that I have read the foregoing and that the facts in it are tnle to the bet of my knowledee and
holier (section 92.525, Florida Statute.).
Signatures))oofyOwnerts) or Owner's)' Authorized Ofticer/DirectodPartner/Nlanager who signed above:
By: D V • �/ By
Re,. nvcawnrn R—drop.
STATE OF FLORIBA
S T. li I E COUNTY
TIIISTr"_.I,JERl IFYT�ft),TTI-IIS ISR
TRUE G0,RR-,'-Cti;OPY0FTFIE
0RIGI,A L
EDIN Ntuty
, � R_ CLERK
®y
'G, -Clerk
[fie: - 3 - ?,�- _D
r-�
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
http://stiucieco.gov/ce
BUILDING PERMIT
Issued: 03/31 /2008 Conf #: 745 Permit #: SLC- 0803-0324
Job Location: 4311 SUNRISE BLVD City: FORT PIERCE
Permit Type: Roof
Job Description: TEAR- OFF - REROOF (FLAT) ONLY MODIFIED BITUMEN 1200 SF - FLAT
Subdiv:
Lot:
Block:
Parcel: 2433-431-0003-000/1
Page 1
Contractor TAYLOR, CHAD G J A TAYLOR ROOFING INC (772) 466-4040
302 MELTON DR
Property Owner BERTHA LEMIRE
4311 SUNRISE BLVD
Setbacks Left: Right:
Number of Units: 1.00 Floors: 1
Minimum Floor Elevation:
Job Value: $ 4,200.00
FT PIERCE, FL 34982
(772) 465-2299
FORT PIERCE, FL 34982-6973
Front: Rear:
Buildings: 1
Flood Map: Flood Zone:
Zoning: RS-3
Square Footage: 0.00
Elev:
Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code
including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all
requirements of the 2004 Florida Building Code.
NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the
records of this County, and there may be additional permits required from other governmental entities such as water management districts, state
agencies, or federal agencies. s:553.79(10), F.S.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S.
Christopher Lestrange
Building Official Date
For Automated Inspections, Call (772) 462-1261
For Questions, Call (772) 462-2172
St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and
become null and void if work authorized by such Building Permit is not commenced, having called for and
received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work
is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of
issuance of the Building Permit.
�L1fi1P.; !/flt?� J
Code Compliance Division
2300 Virginia Avenue
Ft Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
http://stiucleco.gov/ce
Date: 31 March 2008
Job Address: 4311 SUNRISE BLVD
Received By: dimonb
Paid With: ck
Paid By: JA Taylor Roofing
Building
Receipt
Sign:
Receipt#:
0000061838
'ermit Number:
SLC- 0803-0324
Amount:
$180.00
2redit Card Number:
Check Number:
44666
N
i
i
l
,
ct
Code Compliance Division
2300 Virginia Avenue Fees/Pa entS
Ft 111
Pierce, FL 34982 y
Phone: (772) 462-1553 Fax:(772)s
462-2522
I..aw.1/wLl..wlwww ww../ww
PROPERTY INFORMATION Inspections
Address 4311' ' SUNRISE BLUD- Owner` : Bertha Lemire
Unit #
-City 1 State I Zip FPR `` FL-'.` 349 2 . .
'°Parcel # 2433 431=0003=000/1 Iurisdict�on„ CTY Zoning RS 3 -of #
uture Land Use, Residential Urban Ye Subdivision ' 2433431 Block,'
•N INFORMATION
Pe'rmitType .[Ioof�
0803-0324;- 1pplicaton Type `er the Counter Permit�� Other
F
i
Issued Activity.Type'I _ `. "Stories �°1 itomati'cSpnnkierSystem?,`j
L_.
FEES Add Fee
=4
Code ;- a Type ❖ Account'** Quantity Amount Date Posted'Paid? Fee
,BIMS651 y ]06-BIMS 4912415 322050 200 $5.00 04/01/2008 = a
BIMS651, 06-BIMS 491 _2415 322050'200 $5.00 04/0V2008° Yes
° Permi755 06-Permit Fee- Roof'- (1 &2 Family 491 2415322000 200 , $75:00 '' 04/91/2008 Yes
Permi722 06 Pem it Fee -'Inspections (each) 491:2415 322000 200 - $50_.0Q ; , O'4/01 /2008 Yes4
, PlanR838 ,�_,. 06 `Plan Rewevir OTC Fermits-,(One 49,1,2415 322000 200 • e �, $50 00 0,4/01/2008 ., Yes , -
�• .
Ao
0ate�Entei.6d 03/31/2008 Date Paid 03/31/2008 ,
Entered By �debb�e Historical?, C o J e
_ .,., � F •yam°• _
Receipt # Amount Date Posted
0000061,838 $180,00 ' ` " 04/01/2008 Paid By JA Taylor Roofing
' 5 Payment,Type , ck"•1 1-1� Check
jjj
Mastercard (MC), Vise (VS), Fee
Check # 44666 ❖
Waived (FW), Refund. (RF),
Credit Card Number 1 Reversal (RV)
,redit Card -Authorization °
Issued To
Received'By. dimonb
•_ y , `Date Paid_a03/31/2008,
Fee Summary Total Fees$ 180.00 Payments $180.00
To'reiresh the b.alanee, please'clickthe'.
to RefreshDa ' button aCthe top,ofthe'form, , `
Ap M I A M I•DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
Johns Manville Corporation
717 171h Street
Denver,. CO 80202
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET. SUITE 1603
MIAMI. FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by Miami -Dade County Product Control
Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and
other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve .the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Division that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the High Velocity
Hurricane Zone of the Florida Building Code.
DESCRIPTION: Johns Manville APP Modified Bitumen Roofing Systems Over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,
then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 03-0212.01 and consists of pages 1 through 16.
The submitted documentation was reviewed by Jo e L. Acebo
4
.j'6363
2� NOA No.: 06-0417.09
Expiration Date: 06/14/11
lag Approval Date:
,ILE Page 1 of 16
5/3� o
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub_Category:. APP Modified Bitumen
Deck Type: Wood
Maximum Design Pressure -52.5 psf
Fire Classification: See General Limitation #1
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
JM APP Base 150 sq. ft. roll ASTM D 5147 APP modified asphalt, fiberglass
reinforced, smooth surfaced base. sheet.
APPeX 4S 32.8' x 3.28; 90 ASTM D 6222, APP modified asphalt, polyester
lb. roll type I, grade S reinforced, smooth surfaced membrane.
_*APPeX 4.5M 32.8' x 3.28; 90 ASTM D 6222, APP modified asphalt, polyester
lb. roll type I grade G reinforced, mineral surfaced membrane.
APPeX 4.5MFR
32.8' x 3.28; 90
ASTM D 6222, APP modified asphalt, polyester
lb. roll
type I grade G
reinforced, fire -retardant, mineral surfaced
membrane.
APPeX 180
32.8' x 3.28 ; 90
ASTM D 6222,
APP modified asphalt, polyester
lb. roll
type I, grade G
reinforced, smooth surfaced membrane.
Bicor MFR
39-3/8" x 34'
ASTM D 6223
APP modified asphalt, polyester / glass
reinforced, granule surfaced membrane.
Tricor MFR
39-3/8" x 34'
ASTM D 6223
APP modified asphalt, polyester / glass
reinforced, granule surfaced membrane.
Bicor S
39-3/8" x 34'
ASTM D 6223
APP modified asphalt, polyester / glass
reinforced, smooth surfaced membrane.
Tricor S 39-3/8" x 34' ASTM D 6223 APP modified asphalt, polyester / glass
reinforced, smooth surfaced membrane.
PermaPly 28 36' x 108 ; ASTM D 4601 Type II asphalt impregnated and coated
72 lb. roll glass fiber base sheet
NOA No.: 06-0417.09
Expiration Date: 06/14/11
Approval Date:
Page 2 of 16
Test Product
Product Dimensions Specification Description
Ventsulation 36" x 36' ASTM D 4897 Fleavy duty fiber glass base sheet
Type II impregnated and coated on both sides with
asphalt with or without fine mineral
stabilizer.
JM Topgard Type B ASTM D 1227 Fire rated, fibercd, non -asbestos, clay
water base asphalt emulsion.
JM Fibrated Aluminum ASTM D 2824 Fire rated, fibered, non -asbestos
Roof Coating . aluminum coating.
JM Premium Fibered ASTM D 2824 Fire rated, fibered, non -asbestos asphalt
Aluminum Roof Coating aluminum coating.
APPROVED INSULATIONS:
TAaix 2
Product Name
Product Description
Manufacturer
(With Current NOA)
ENRGY 2, ENERGY 3, PSI-25
Isocyanurate Insulation.
Johns Manville
ENRGY 2 Composite
Polyisocyanurate insulation laminated to
Johns Manville
perlite.
ENRGY 2 Plus
Polyisocyanurate insulation laminated to
Johns Manville
wood fiber.
Fesco Foam, DuraFoam
Isocyanurate Insulation with perlite facer
Johns Manville
Retro-Fit Board, DuraBoard
A high -density perlite roof insulation.
Johns Manville
Fesco Board
Rigid perlite roof insulation board.
Johns Manville
Fiber Glass Roof Insulation
Fiberglas roof insulation.
Johns Manville
ACFoam 11
Isocyanurate Insulation
Atlas Roofing Corp.
Wood Fiberboard
Regular wood fiber insulation
Generic
High Density Wood Fiberboard
IIigh Density Wood Fiber insulation board.
Generic
Perlite Insulation Board
Perlite Insulation
Generic
Type X Gypsum
Gypsum Wallboard
Generic
XPS
Extruded polystyrene
Generic
Stnictodeck
High Density Wood Fiber insulation board.
Masonitc
NOA No.: 06-0417.09
Expiration Date: 06/14/11
Approval Date:
Page 3 of 16
Ap
APPROVED FASTENERS:
TABLE 3
Fastener Product
Product
Manufacturer
Number. Name
Description
Dimensions
(With Current NOA)
1. UltraFast
Insulation fastener for wood
Johns Manville
and steel.
2. U1traFast ASAP
Pre -assembled Insulation
Johns Manville
fastener and plate
3. U1traFast Metal Plate
Galvalume. AZ55 steel plate
3" square &
.Johns Manville
3" round
4. Olympic Fastener #12 &
Insulation fastener
Olympic Mfg. Group
#14
5. Olympic Fastener ASAP
Pre -assembled Insulation
Olympic Mfg. Group
fastener and plate
6. Olympic G-2
Galvalume AZ55 steel plate
3.5" round
Olympic Mfg. Group
7. Olympic Standard
Galvalume AZ50 steel plate
3" round
Olympic Mfg. Group
8. Tru-Fast
Insulation fastener for steel
The Tru-Fast Corp.
and wood decks
9. Tru-Fast Plates
Galvalume AZ55 steel plate
3" round
The Tru-Past Corp.
EVIDENCE. SUBMITTED:
'rest Agency
Test Identifier
Description
Date
Factory Mutual Research Corp.
J.I. OXOA9.AM
Wind Uplift
03/25/94
J.I. OW6A2.AM
Wind Uplift
02/05/93
J.I. OX7A4.AM
Wind Uplift
08/26/93
J.I. 3001482
08/11/98
J.I. 3002823
04/01/99
J.1. 3003468
02/02/00
J.I. 3007148
04/ 19/00
3009499
4470
04/04/01
3011248
4470
11/01/02
3012974
4450
06/03/02
Underwriters Laboratories, Inc.
R-10400 Published Annually
Exterior Research &.Design, LLC
#4361-2.04.97-1 TAS I
I4(J) —Wind Uplift 04/15/97
10390A.12.97-1 TAS 114(J)
—Wind Uplift
12/15/97
10390A_ 10.97-1 TAS 114(J)
— Wind Uplift 10/15/97
10391.01.03 TAS 114(J)
& TAS 117
(B) 01/29/03
NOA No.: 06-0417.09
Expiration Date: 06/14/11
Approval Date:
Page 4 of 16
Membrane Type: APP
Deck Type 11: Wood, Non -Insulates:]
Deck Description: `9/32" or greater plywood or wood plank
System Type E: Base sheet mechanically fastened.
All General and System limitations apply.
(Base Sheet: (Option #I) One ply of JM APP Base, PermaPl_y_28, Glasbase Plus or
'/\ Ventsulation mechanically fastened to the deck with JM U1traFast, Olympic or
Tru-Fast metal plates and fasteners at a 4" side lap 12" o.c. and two rows staggered
in the center of the sheet 18" o.c.
(Maximum Design Pressure —45 psf — See General Limitation #9.)
(Option #2) Minimum two plies of JM PermaPly 28 or Ventsulation
simultaneously fastened to the deck lapped 4" and fastened with approved roofing
nails and tin caps 9" o.c. at the lap and two rows staggered in the center of the
sheet 12" o.c.
(Maximum Design Pressure —52.5 psf- See General Limitation #7.)
(Option #3) Minimum two plies of JM PermaPly 28 or Ventsulation
simultaneously fastened to the deck with JM Ultrafast fasteners and Metal Plates
spaced 9" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the
sheet.
(Maximum Design Pressure —52.5 psf—See General Limitation V.)
Ply Sheet:
(Optional) One or more plies of JM APP Base, APPeX 4S or APPeX 180 heat
welded to base sheet.
Membrane:
One or more plies of APPeX 4S, APPeX 180, M- P`eX— 4:5M or APPeX 4.5 MFR
heat welded.
Surfacing:
(Optional) Install one of the following for all systems that do not achieve
acceptable fire ratings through the use of FR membrane sheets.
1. 400 lb./sq, gravel or 300 lb./sq. slag in a flood coat of approved mopping
asphalt at a rate of 60 lb./sq.
2. Karnak 97, Karnak 97 AF, Monsey Premium Long Life Aluminum Roof
Coating Asbestos Free or Monsey Prograde Aluminum, JM Topgard Type A,
Topgard Type B, JM Aluminum RF CT, Grundy AL MB aluminum coating at
a rate of 1-1/2 gal/sq Monsey Aquabrite, Gardner asphalt emulsion, APOC
Sunbright 400 or Henry 229 Aluminum Emulsion at 2'/z gal/sq or APOC 212
Aluminum Roof Coating at 3 gal/sq.
3. Grundy 20 F asphalt emulsion, Endure Asphalt Emulsion, APOC 302 or 302
AF applied at 2% gal/sq with optional 60 lbs./sq. of roofing granules
embedded in wet coating.
Maximum Design
Pressure:
See Fastening Options Above
NOA No.: 06-0417.09
Expiration Date: 06/14/11
Approval Date:
Page 15 of 16
.40
WOOD Dr('K SYSTEM LIMITATIONS -
slip'
1 \heet is required Willi 1'1\ 4 and 1'Iv 6 nhen used ;,s :1 nu-ch:uiirhlly Listened hasr „r nu'hor
sheet.
GENERAi, .LIMITATIONS:
]. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the I:VT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top laver
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum
design pressure of -45 psf.
5. Fastener spacing for insulation attachment is'based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value.
as field-tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor; base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and scaled by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calctilations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS l 1 l and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
END OF THIS ACCEPTANCE
NOA No.: 06-0417.09
Expiration Date: 06/14/11
Approval Date:
Page 16 of 16
MIAMIDADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVLSION
NOTICE OF ACCEPTANCE (NOA)
W.R. Grace & Co.
62 Whittmore Avenue
Cambridge, MA 02140
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by Miami -Dade County Product Control
Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County
and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within
their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade
County Product Control Division that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code and the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Grace Ice & Water Shield@
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 02-1113.02 and consists f pag s 1 through 5.
The submitted documentation was reviewed by Jorge L. Ace bC. .
SE��N�ARY
0y75214;103
-ILATExp i te133
BARRIER l ate: 01/03/08
3/ -3� Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Underlayment
Materials: SBS
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Test Product
Product Dimensions
Specifications Description
Grace Ice & Water Thickness 40
ASTM D1970 Self -adhering SBS modified,
Shield@ mils, 36" x 75'.
bitumen underlayment membrane
reinforced with polyethylene film.
Bituthene® P-
Primer for masonry or concrete
3000 Primer
surfaces.
Bituthene@ Water
Water -based surface primer applied
Based Primer
in lieu of P-3000.
Bituthene® Liquid
For application at transition
Membrane
between unlike materials at angles
of 60 Deg. or greater.
EVIDENCE SUBMITTED
Test Agency Test Identifier
Test Name/Report
Date
Housing and Urban
1056C '
07/17/91
Development Release
International Conference of
3997
12/19/89
Building Officials Report
Construction Research
5670
10/12/92
Laboratory, Inc.
Underwriters
88NK3269
09/28/88
Laboratories.
R1339
11/01/93
R7910
11/01/93
Warnock -Hersey
PA 103
08/24/93
Simpson, Gumpertz & Heger,
ASTM D 570-81
11/06/93
Inc.
ASTM D E96-90
11/06/93
PRI Asphalt Technologies WRG-017-02-01
ASTM D1970
10/17/05
NOA No.: 07-0524.03
(D Expiration Date: 01/31/13
Approval Date: 01/03/08
Page 2 of 5
APPROVED ASSEMBLIES:
Deck Type 1:
Wood
Deck Description:
19/32" or greater plywood or wood plank
System Type A(1):
Anchor sheet mechanically fastened.
Prepared Roofing:
Any prepared roof covering assembly with a current Miami -Dade
County Notice of Acceptance listing Grace Ice & Water Shield® as an
approved underlayment for the assembly.
All General and System limitations apply.
Anchor Sheet:
One or more plies of ASTM D 266 Type lI or ASTM D 2626 with a
minimum 4" side lap and a 6" end lap mechanically fastened to deck
with approved nails and tin caps 6" o.c. at the laps and two staggered
rows 12" o.c. the field of the roll.
Grace Ice & WaterShield®:
Cut Grace Ice & Water Shield® membrane into 10 to 15 feet lengths
and reroll. Peel back 1 to 2 feet length of release paper, align
membrane on the lower edge of the roof and place the'firse 1 to 2 feet
length of membrane. Pull the release paper under the membrane and
continue to peel it from the membrane, while pressing the membrane
in place. Roll lower edges firmly with a wallpaper or other type hand
roller. Always begin application at low point of the roof, applying
membrane in shingle fashion to shed water.
Grace Ice & Water Shield® shall be overlapped to shed water a
minimum of 3'/2". End laps shall be a minimum of 6". Membrane shall
not be applied to the exposed face of the roof edge.
Valleys: For valley application, peel the release paper, center the sheet over the
valley or ridge, drape and press it in place, working from the center of
the valley or ridge outward in each direction. Apply membrane
starting at the low point and work upwards. Valley assemblies
require double application.
Eave Termination: Metal drip of eave edges shall be installed over the primary
membrane.
WOOD DECK SYSTEM LIMITATIONS:
1. Joints in plywood or wood planks shall not be greater than 1/8 of an inch wide.
2. All wood decks shall be fastened in accordance with applicable building code, and all existing
fasteners shall be reseated to avoid any protruding fastener heads.
3. Bituthene Liquid Membrane shall be applied at all angles greater than 60°, or where unlike
materials join. Bituthene Liquid Membrane fillet shall be applied in compliance with detail 'A'.
Y
NOA No.: 07-0524.03
,r Expiration Date: 01/31/13
Approval Date: 01/03/08
Page 3 of 5
r
Deck Type 3: Concrete Decks, Non -insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(2): Grace Ice & Water Shield® fully adhered to primed concrete deck.
Prepared Roofing:
Any prepared roof covering assembly with a current Miami -Dade
County Notice of Acceptance listing Grace Ice and Water Shield® as
an approved underlayment for the assembly.
Note: Concrete decks shall be
fully primed and allowed to dry prior to the application of Grace
Ice &Water Shield®
Deck Primers:
Bituthene Water Based Primer:
A water based primer packaged as a concentrate to be mixed 50% with
water, and applied at minimum rate of 500 ft2 / gal.
Bituthene P-3000 Primer:
A solvent rubber -based primer applied at minimum rate of 250ft2 / gal.
Grace Ice and WaterShield®:
Cut Grace Ice & Water Shield® membrane into 10 to 15 feet lengths
and reroll. Peel back 1 to 2 feet lengths of release paper, align
membrane on the lower edge of the roof and place the first 1 to 2 feet
lengths of membrane. Pull the release .paper under the membrane and
continue to peel it from the membrane in place. Roll lower edges
firmly with a wallpaper or other type hand roller. Always begin at low
point of the roof, applying membrane in shingle shingle fashion to
shed water.
Grace Ice & Water Shield® shall be overlapped to shed water a
minumum of 31/2". End laps shall be minimum of 6". Membrane shall
not be applied to the exposed face of the roof edge.
Valleys:
For valley application, peel the release paper, center the sheet over the
valley or ridge, drape and press it in place, working from the center of
the valley or ridge outward in each direction. Apply membrane
starting at the low point and work upwards. Valley assemblies
require double application.
Eave Termination:
Metal drip of eave edges shall be installed over the primary
membrane.
Maximum Design
Pressure:
(As listed in the prepared roofing sytem's Notice of Acceptance)
CONCRETE DECK SYSTEM LIMITATIONS:
Grace Ice & Water Shield® shall only be applied over smooth, clean, dry, properly primed
structural concrete decks.
2. Bituthene Liquid Membrane shall be applied at all angles greater than 600, or where unlike
materials join. Bituthene Liquid Membrane fillet shall be applied in compliance with detail 'A'.
NOA No.: 07-0524.03
Expiration Date: 01/31/13
Approval Date: 01/03/08
Page 4 of 5
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Grace Ice & Water Shield® shall not be left exposed to weather for longer than 30days.
3. All bonding surfaces shall be clean, dry and free from sharp or uneven edges.
4. Primer is required on all concrete and masonry surfaces.
5. All work shall be performed by a Dade County licensed roofing contractor. Contractor shall be
familiar with the details and specifications published by the manufacturer.
6. Minimum deck requirements shall be in compliance with applicable building code.
7. Grace Ice & Water Shield® shall not be applied over an existing roof membrane as a recover
system but may be applied over a roofing Base/Anchor sheet underlayment.
8. Grace Ice & Water Shield® may be used with any approved roof covering Notice of Acceptance
listing Grace Ice & Water Shield® as a component part of an assembly in the Notice of
Acceptance. If Grace Ice & Water Shield® is not listed, a request may be made to the Authority
Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind
uplift resistance, and fire testing results.
9. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking
panels. Sweep the deck thoroughly to remove any dust and debris prior to application.
10. Grace Ice & Water Shield® may be used in Asphaltic shingles, wood shakes and shingles, quarry
slate roof assemblies. Grace Ice & Water Shield® shall not be used as roof tile underlayment.
11. When applying the membrane in the valley, start at the low point and work to the high point,
rolling the membrane from the center outward in both directions.
12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving
special attention to overlap areas.
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current
Product Control Notice of Acceptance and applicable Building Code.
14. All membranes shall bear the imprint or identifiable marking of the manufacturer's name or logo,
or following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
logo.
END OF THIS ACCEPTANCE
" Y NOA No.: 07-0524.03
Expiration Date: 01/31/13
Approval Date: 01/03/08
Page 5 of 5