HomeMy WebLinkAboutSUBMITTED PAPERSi •
Date: T69 Fee Due.;,--; -91i Recei t# Permit #
)9104:�- 7S -
Bq/=,SSt. Lucie County Building & Zoning
2300 Virginia Avenue Ft. Pierce, FL 34982-5652
Tel. 561462-1553
SPECIALTY PERMIT APPLICATION
❑ Electrical ❑ Plumbing ❑ HVAC ❑ Fence
❑ Shed ❑ Demolition ❑ Gas ❑ Siding
See page 2 for instructions and additional paperwork required for specialty permits
1. Location/Site Address:
2. Parcel -ID Number:
Office Use
Section
Townshi
Range
Map Page
Zoning
Land Use
Initials
Only
3. Description of Project or Work Activity: �f6a.<-
4. Owners Information
Name: MaLA�y 0-0, (Z\N�
Address: a' kb \
City: 2W, X-0O3 State: F( ,
rt•
6. Value of Construction: S cS3g� ao
5. Contractors Information
FL Reg/Cert #: C\4 C D-":)- o(o 37
County Cert#: 9057
Business
�� ��Name: �% ���u �
``��
Phone �tiU►-�Fax LVdQ 1437
OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done
in compliance with all applicable laws regulating construction and zoning.
SCANNED
BY
S$. LUCI@ County
PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIERIOWNER
STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS �t DAY OF
( 20-MBY 7 YCAXC AHO IS ERSONAI LY KNnwU Tn MEbR WHO HAS PRODUCED
AS IDENTIFICATION.
1 rscp� (seal)
SIGNATURE OF NOTARY TYPE bR PRINT NAM OF NOTARY ✓� I
TITLE: NOTARY PUBLIC COMMISSION NUMBER I `
2or p Notary Public State of Florida
Cathy 4 Gaspar
Y My Commission OD739689
St. Lucie County Specialty Permit Application rev. 8/25/05 ding'�-aFpa�' Expires 12/05/2011
Wednesday, Apr 02, 2008 01:52 PM
Code Compliance Division BUILDING PERMIT
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
http://stiucieco.gov/ce
Issued: 04/03/2008 Conf #; 808
Job Location: 2101 EASY ST
Permit Type: Plumbing
Job Description: INSTALL SOLAR WATER HEATING SYSTEM
Subdiv: Indian River Estates Unit 9
Lot: 1
Block: 97
Permit #: SLC- 0804-0023
City: FORT PIERCE
Parcel: 3402-610-0657-000/6
Page 1
Contractor ZRALLACK ROBERT JOSEPH SOLAR ENERGY SYSTEMS (772) 464-2663
160 SMALLWOOD AVE FT PIERCE, FL 34982
Property Owner MAURICE WHITE
2101 EASY ST FT PIERCE, FL 34982-3702
Property Owner SHEILA WHITE
2101 EASY ST FT PIERCE, FL 34982-3702
Setbacks Left:
Number of Units: 1.00
Minimum Floor Elevation:
Job Value: $ 2,387.00
Right: Front:
Floors: 1
Flood Map
(772) 465-3299
Rear: Zoning: RS-4
Buildings: 1 Square Footage: 0.00
Flood Zone: Elev:
Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code
including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all
requirements of the 2004 Florida Building Code.
NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the
records of this County, and there may be additional permits required from other governmental entities such as water management districts, state
agencies, or federal agencies. s:553.79(10), F.S.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S.
Christopher Lestrange
Building Official Date
For Automated Inspections, Call (772) 462-1261
For Questions, Call (772) 462-2172
St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and
become null and void if work authorized by such Building Permit is not commenced, having called for and
received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the
work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date
of issuance of the Building Permit.
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
hftp:i/stiucleco.gov/ce
Date:
03 April 2008
Job Address:
2101 EASY ST
Received By:
humphreya
Paid With:
CK
Paid By: SOLAR ENERGY SYSTEMS
Building
Receipt
Receipt #: 0000061908
'ermit Number: SLC- 0804-0023
Amount: $130.00
�redit Card Number:
Check Number: 50303
Sign:
'Property Appraiser - St.Lucie County, FL
Page 1 of 1
PROPERTY RECORD CARD
Maurice White Record: 1 of 1
<<Prev Next» Spec.Assmnt
Taxes Exemptions Permits Home Print
Property Identification
Site Address: 2101 EASY ST
ParcellD: 3402-610-0657-000-6
Sec/i'own/Range: 12 :36S :40E
Account #: 38731
Map ID: 34/12S
Land Use: SF Res
Zoning: RS-4
City/Cnty: ST. LUCIE COUNTY
Ownership and Mailing
Legal Description
Owner: Maurice White Sheila White
INDIAN RIVER ESTATES-UNIT-09- BLK 97 LOT 1 (MAP 34/12S) (OR
Address: 2101 Easy St
345-2557)
Fort Pierce FL 34982-3702
Sales Information
Assessment Final
Total Land and Building
Date Price Code Deed
Book/Page 2007 FV: 168500
Land Value: 70000 Acres: 0.29
12/1/1980 64500 00 CV
0345 / 2557 Assessed: 168500
Building Value: 98500
5/1/1980 0 01 CV
0331 / 2587 Ag.Credit: 0
Finished Area: 1782 SgFt
9/1/1979 0 01 CV
0316 / 1565 Exempt: 0
10/1/1976 1700 01 CV
0260 / 1823 Taxable: 168500
Taxes: 3194.96
BUILDING INFORMATION
Exterior Features
View:
-
RoofCover:
SA - Asph Shingle
RoofStruct:
HP - Hip
ExtType:
HC- - HC-
YearBit:
1980
Frame:
Grade:
C- - C-
EffYrBlt:
1980
PrimeWall:
BS - CB Stucco
StoryHght:
0010 - 1 Story
No.Units:
1
SecWall:
-
Interior Features
BedRooms:
3
Electric:
MX - MAXIMUM
PrmintWall:
DW - Drywall
FuliBath:
2
HeatType:
FHA - FrcdHotAir
AvgHUFI:
STD
1/213ath:
0
HeatFuel:
ELEC - Electric
Prm.Flors:
CU - Carpet
%A/C:
100
%Heated:
100
%Sprinkled:
0
Special Features and Yard Items
Land Information
Type
Y/S Qty.
Units Qual. Cond.
YrBlt. No. Land Use
Type
Measure
3CNT - 3CNT
S 1
1 AV AV
1980 1 0100-SF Res,
215 -Front Ft
100
SDSF - SITE DEV S-F
Y 1
1 AV AV
2001
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
Depth
125
http://www.pasle.org/pre.asp?prelid=340261006570006 4/2/2008
SOLENE MOUNTING
BRACKET W/ LAG BOLT
- u
7H RESPONSIBII�TY OF THE
COLLECTORS ,SHALL ��
NOT BE INSTALLED IN CORNER
SOLENE BRAND
AS SHOWN BELOW
CONTRACTOR OF RECORD •
ZONES AS SHOWN ON DIAGRAM
COLLECTOR
2'
SOLENE MOUNTING BRACKET
W/ LAG BOLT AS
SHOWN BELOW
SOLENE BRAND
y�'�
o
COLLECTORS
Ld
RIDGE
0
0
HIP
III M4
CONDITION
SOLENE BRAND
COLLECTOR
ROOF ZONE 3
CORNERS
LONG DIMENSION
GABEL END ROOF,
HIP ROOF GENERAL CONDITION
CONDI11ON ROOF CONER ZONE SHALL BE 10 PERCENT
OF SHORT DIMENSION OF BUILDING, OR 40 -
1 PLAN OF COLLECTORS PERCENT OF MEAN ROOF HEIGHT, OR 7 FT
— WHICH EVER IS SMALLER.
—3 SCALE: 3/16"=1'-0" 2 ROOF LAYOUT PLAN
GENERAL NOTES: S-3 SCALE: NONE
1. COLLECTOR CONNECTIONS SHOWN HAVE BEEN DESIGNED TO RESIST WIND LOADS OUTLINED IN THE 2004 BUILDING CODE, WITH 2O06
SUPPLEMENTS, CHAPTER 16 FOR 140 MPH EXPOSURE "C" WIND VELOCITY AND PER ASCE 7-02, CHAPTER 6.0 FOR 140 MPH EXPOSURE
"C" WIND VELOCITY TYPICALLY.
2. LAG BOLT CAPACITIES AND EMBEDMENTS ARE BASED UPON "NATIONAL DESIGN SPECIFICATION FOR STRESS GRADE LUMBER AND
FASTENINGS" AS PUBLISHED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION.
3. ALL CONNECTIONS ARE FOR ROOFS 0' TO 45' MAX SLOPE CONDITIONS.
4. ALL CONNECTORS ARE FOR MEAN ROOF HEIGHTS NOT TO EXCEED 30'-0".
5. APPLY ROOF GRADE SEALANT TO ALL CONTACT SURFACES.
6. ALTERNATIVELY SOLENE MOUNTING BRACKET CAN BE FASTENED TO THE SOLENE COLLECTOR WITH EITHER (1) %" STSTL BOLT AND
NUT, OR (2) Y" SELF TAPPING SHEET METAL SCREWS.
ROOF
SHEATHING
SOLENE
MOUNTING
BRACKET
3"
4X LOCATE BETWEEN
TRUSSES AND NAIL
WITH 4 16D
NAILS AT EACH END
SOLENE BRAND
COLLECTOR
W DIA STAINLESS
STL LAG BOLTS AT EACH
SOLENE BRAND CONN TYP.
USED TRUSS 1.
3 BRAND NAILER INST.
S-3 SCALE:
ROOF
SHEATHING
SOLENE
MOUNTING
BRACKET
E NOTE 3
SOLENE BRAND
COLLECTOR
%" DIA STAINLESS, r WOOD TRUSS
STL LAG BOLTS AT EACH L 2 SYP
SYSTEM
SOLENE BRAND CONN TYP. OR BETTER
SH I N GLE/M ETAL
iBUILT UP ROOF
W SCALE'=1/2"=1'-0"
FLAT
CONCRETE
11LES
3"
ROOF
SHEATHING
%" DIA STAINLESS
STL LAG BOLTS AT EACH
SOLENE BRAND CONN TYP.
3"X3"X1b" THK 3" L 6063T6
ALUM SQRTB WITH 1 "DX7y6"
THK 2-Y4 L ALUM TUBE
INSERT BOTH ANODIZED
SOLENE BRAND FLUSH
a MOUNT STAND OFF ASSY
S-3 SCALE: NTS
r. f
MIJSTAE KEPT ON JOB OR
NO S ECT10N WILL BE MADE
2x PT OR UNISTRUT CONTINUOUS ALONG
PANEL FOR MOUNTING
W/ 3/8" ST STL ALL—THRD ROD W/ NUT
& WASHER EA END — PROVIDE "LOCTITE" WOOD TRUSS
1T ALL NUTS. CENTER RODS ® 3'-0" o/c SYSTEM #2 SYP
MAX SPACING OR BETTER
MISSED TRUSS SOLENE
BRAND SPANNER INSTALL
SOLENE MOUNTING
BRACKET AND STAND
OFF ASSY
SOLENE BRAND
COLLECTOR
WOOD TRUSS
M #2 SYP
OR BETTER
NOTE: CUT OUT OR REMOVE
11LE TO INSTALL STANDOFF
ASSY. THEN REINSTALL TILES
AROUND MOUNTING
HARDWARE
5 FLAT CON C. TILE ROOF
—3 SCALE: 1-1 /2"=1'-0"
WOOD TRUSS
SYSTEM #2 SYP
OR BETTER
%" DIA STAINLESS
STL LAG BOLTS AT EACH
SOLENE BRAND CONN
TYP.
SOLENE MOUNTING
BRACKET AND STAND
OFF ASSY SOLENE BRAND
COLLECTOR
BARREL
TILES
ROOF
SHEATHING
NOTE: CUT OUT OR REMOVE
TILE TO INSTALL STANDOFF
ASSY. THEN REINSTALL TILES
AROUND MOUNTING
HARDWARE
s BARREL TILE ROOF
S-3 SCALE: 1-1 /2"=1'-0"
0
0
PROJECT #: 60136
DESIGNED: REC21408
SCALE: NOTED
DRAWING NO.
S-3
SHEET 1 OF 1