Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and Zoning 2300 Virginia Avenue M®�, Ft. Pierce, FL 34982-5652 SCAjgjVE® - aff772-462-1553 8 Y #, kuCie county APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 1006 Saeger Avenue Fort Pierce, 34982 2. S/D NAME: White City S/D SITE PLANNAIvIE: Smith Residence 3. PROPERTY TAX ID #: 3403-502-0284-000-1 ✓✓ 4. LEGAL DESCRIPTION (attach extra sheets if necessary): White City S/D 09 36 40 E 107.23Ft of W 618. FT of N 105 FT of S130 FT of lot 223 8 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. NO. NO. 223 tot- 13 x 105 9. PARCEL SIZE: ACRES/SQ FT. 11 5 JLOT DIMENSIONS L1111,N. N/i� . 10.. SETBACKS (ACTUAL) FRONT.t,4& BACK: I6.6td2IGHT SIDE: 120W LEFT SIDE: 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION RIX SCREEN ROOM N SG NEW ❑ EXISTING 18 X 342 ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL.FENCE _ Linear feet ❑ ROOF SYSTEM OVER' EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X OTHER: Concrete N SG [ NEW ❑ EXISTING 18 X 1-9j— 342 TOTAL SQUARE FOOTAGE; OF CONSTRUCTION 342 ; ` 12. VALUE OF CONSTRUCTION: $ 6800.00 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated. value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 00.1-02 Rev. 2/19107 a1 ' t/ OWNER INFORMATION V1, NAME: Robert Smith ADDRESS. 1006 Seager Avenue CITY: FortPierceSTATE: FL ZIP 34982 PHONE (DAYTIME): (=772 370-8710 email: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE - FEE SIMPLE TITLEHOLDER: ADDRESS: CITY:. STATE: ZIP PHONE (DAYTIME): CONTRACTOR INFORMATION'J- 71 - STATE OF FLORIDA REG./CERT #: ST. LUCIE COUNTY CERT #: 4763 BUSINESS NAME: Pioneer Screen C6,11nc II QUALIFIER'S NAME: MIchael J Newman ADDRESS. 1682 SW Biltmore Street CITY: POrt Saint Lucie STATE: FL ZIP 34984 772- 340-43113 340-4626 PioneerscreenCamsn.com PHONE (DAYTIME): .FAX NO. email: ARCH1TECT/ENGINP_ER-,'BIN'1 Inc 1950 NE 170TH-.Avenue ADDRESS. CITY: Willis -ton STATE: FK1. ZIP 32696. PHONE (DAYTIME): (352) 5.29-0080 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. EJ 2 scaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in M[H Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. not required for construction unrelated to storms) OFFICE SKDNLU�'�;-.'."� : . .......... ... ........ ZOMNG SECTION 09 TOWNSHIP � RANGE Lt&E7 MAP NO. aogs ZONING LAND USE FLA LOT CVG % Additional Pen -nits Yes no REPORT CODE BIMS FEE 00 MISC FEES TOTAL FEES BZONINGREVIEW:: . I.- ..... ..... REVIEWS ZONING ZONING - REVIEWED BY PLANS EXAMINER misc. VEGETATION VALUE OF CONSTRUCTION USING ICC TABLE DATE COMPLETE iJ Lf L4 .371 INITIALS PLAN REVIEW ,SPENFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: CO 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. ® All roof pans or composite panels, with gauges and spans, must be sized and identified. ® All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. ® All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. : , © Barrier railings, if utilized; shall"have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with.the N.E.C.; if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4`h wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. ,If! t CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and. installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU , PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO. ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor/ Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceed the footprint ofstructure that was in existence prior to removal by the storms.' // SIGNATURE STATE OF FLORIDA COUNTY OF�i A11 The foregoing instrument was acknowledged before me this'9 day of 20(&-,-by A 4°Lf, who is personally known to me or who has produced �p N(P as i a ion. ipature of Notary w Kevin J Stewart (SEALiwy Commission ®D354493 l ) "�p4 Expires October 29, 2003 IMPORTANT NOTICES: ATURE STATE OF RI A COUNTY OF' The foregoing instrument was acknowledged before me this day of(),r .P]_, 200&, by lY1 J 1P/.�l' - I who is personally known to me or who has produced as identification. ignature of Notary Kevin J SWAGrt (SEAL) My -Commission DD354413 �' ,�' Expires ociobar 29, 2003 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNERIBUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS_ NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. Code Compliance Division 2300 Virginia Avenue Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucleco.gov/ce Issued: 04/22/2008 Job Location: 1006 SAEGER AVE Permit Type: Building (Miscellaneous) Job Description: 40WILDING PERMIT Page 1 Conf #: 835 Permit #: SLC- 0804-0031 City: FORT PIERCE NEW CONSTRUCTION OF A SCREEN ROOM WITH A NEW CONCRETE SLAB 18' X 18'. SCREEN ROOM NEEDS TO MEET 15' IN THE REAR ON BOTH CORNERS. S/D White City S/D Lot: 223 Block: Parcel: 3403-502-0284-000/1 Contractor NEWMAN MICHAEL J PIONEER SCREEN COMPANY INC II (772) 340-4393 1682 SW BILTMORE ST PORT ST LUCIE, FL 34984 Property Owner ROBERT A SMITH Setbacks Left: (772) 370-8710 1006 SAEGER AVE FORT PIERCE, FL 34982-7646 Number of Units: 1.00 Minimum Floor Elevation: Right: 14.28 Front: Rear: 14.88 Floors: 1 Buildings: 1 Flood Map: 28OF Zoning: RS-3 Square Footage: 0.00 Flood Zone: X Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. ,.moo Building Code Compliance Division. Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stl ucieco. gov/ce Date: 22 April 2008 Receipt #: 0000062284 Job Address: 1006 SAEGER AVE 'ermit Number: SLC- 0804-0031 Received By: dimonb Amount: $130.00 Paid With: CK Zredit Card Number: Check Number: 48731 Paid By: PIONEER SCREEN CO INC Sign: PEA 02c4'00a l _ NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statues the following information is provided in the Notice of Commencement. 1. DESCRiPTfdR 6F PROPERTY (Legal description and street address, if available) TAx FOLIO NUMBER; 3.-�-( 44 -cw - + SUBDIVISION BLOCK TRACT LOTBLDG UNTT �ik,'v= c: SID og 30 c.l� is 18'1 - op u-) LP 2. GENERAL DESCRIPTION OF IMPROVEMENT! 3. OWNER INFORMATION: a. Name_ '/�� b. Address )00 W c Jt.fPQ�?X a P �1'� a4gg0 c. Interesst in property � d. Name and address of fee simple titleholder (if other than Owner) �� 4. CONTRACTOR'S NAML ADDRESS AND PHONE NUMBER: r C 3RZJ • t 1 3�©^� �c 1�LP 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section` 713.13 (1) (b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is specified): 20 WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER A THE ExP ATION OF THE NOTICE OF cc�� i1 RFPIrEME ITT ARE ON ID FD IMPROPER PAYMENTS UND R HAPTER 714 PART I. SECTION 713 13 FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING. CONSULT WITH YOUR LENDER nR AN ATTnPVPV ARAnnc ..,.,— ______ _ __ of Owner or Authorized Officer/Director/Partner/Manager State of Florida County of S't . Lucie A., Print Name and Provide Signatory's Title/Office The foregoing instrument was acknowledged before me this 121�' day of MGey ctk— . 20 OR By 1�b6�.h�- i�' S✓�ll as Ql,cX-xa.,r— (name of erson) (type of authority,... e.g. officer, trustee, attorney in fact) Fo (�$� �� on (name of party on behalf of whom instrument was executed) Personally known or produced the following type of identification: 1— W Pt&- Kevin J Slewut +�c My COmmissiort DD354413 (Signature of Notary Public) '+w�a Expires October 29, 2WS Under Penalties of perjury, I declare that I have read the foregoing and that the facts in it are true to the best of my knowledge and belief (Section 92.525, Florida Statutes). Sig atu e(s) of Owner( ) or Owaer(s)' Authorized Officer/ Director/ Partner/Manag who si ned above: By(�J B � \c1� ' u. ,x a• Rev.08-09-07 (S.Recording) Ito- 4b2� ST LUCIE COUNT( BOARD OF COUNTY COMMISSIONERS PUBLIC WORKS DEPARTMENT BUILDING & ZONING DIVISION FAX COVER SHEET FAX #: (772) 462-2522 PHONE #: (772) 462-1553 DATE: U I :1 1 168 NO. OF PAGES INCL. COVER: 1, -r - TO: �f I<Jn ATTN: RE: C)s �)L4 (Dc)3 l r ' SENDER: PHONE #, COMM r c c Code Compliance Division Review Comments 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 Page 1 http://Stiucieco.gov/ce PROPERTY INFORMATION Address: 1006 SAEGER AVE City / State / Zip: FORT PIERCE Parcel # : 3403-502-0284-000/1 Zoning: RS-3 APPLICATION INFORMATION Permit Number: 0804-0031 Activity Type: Other Permit Type:, Building (Miscellaneous) FL 34982 Jurisdiction: St. Lucie County Lot # : 223 Block: CONTRACTOR INFORMATION Contractor Name: NEWMAN MICHAEL J Business Name: PIONEER SCREEN COMPANY INC II Business Addr: 1682 SW BILTMORE ST City / State / ZIF PORT ST LUCIE, FL 349 Owner(s): Robert A Smith Application Type: Building Permit w/o subs Other Activity: ALUMINUM STRUCTURE W/CONCRETE Stories: 1 Automatic Sprinkler System? ❑ Fax Number 772-340-4626 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Complete Date Released Documents Missing Pending 04/03/2008 1 Comment NEEDS NOC WITH PICK UP Front Counter Review Complete Audrey Humphrey 04/03/2008 04/03/2008 Notified for Pickup Pending Plans Examiner Review Complete Joe Cicio 04/09/2008 04/17/2008 Zoning Review Incomplete Lydia Galbraith 04/04/2008 04/04/2008 04/17/2008 4 Comment 4/17/8 RECEIVED SEALED SURVEY. CORNER OF THE SCREENROOM IS NOT MEETING THE REQUIRED MIN OF 15' REAR SETBACK. WE NEED 2 SEALED CORRECTED SURVEYS. BOTH CORNERS OF THE SCREEN ROOM NEED TO MEET 15' REAR SETBACK. 7 TRANSMISSION VERIFICATION REPORT TIME 04/17/2008 14:01 NAME FAX TEL SER.# .BROH5J320634 DATE,TIME 04/17 14:00 FAX NO./NAME 93404626 DURATION 00:00:28 PAGE(S) 02 RESULT OK MODE STANDARD ECM BOARD OF COUNTY COMMISSIONERS DATE: 0 r) ATTN ST LUCIE COUNTY PUBLIC WORKS DEPARTMENT BUILDING & ZONING DIVISION FAX COVER SHEET FAX #: (772) 462-2522 PHONE ##: (772) 462-15S, 3 NO. OF PAGES INCL. COVER: RE: C) C'C)--2:) l SENDER: lu PHONE # Comm rid c ;` ST LUCIE COUNTY BOARD OF COUNTY COMMISSIONERS PUBLIC WORKS DEPARTMENT BUILDING & ZONING DIVISION FAX COVER SHEET FAX #: (772) 462-2522 PHONE #: (772) 462-1553 DATE: NO. OF PAGES INCL. COVER: 131, ATTN SENDER: (/l� PHONE* Lt 62 in5gi COMMENTS:. SezzLis �xOLnn► ne ?let-7 1 Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 httpJ/stlucleco.gov/ce Review Comments PROPERTY INFORMATION Address: 1006 SAEGER AVE City / State / Zip: FORT PIERCE FL 34982 Parcel # : 3403-502-0284-000/1 Jurisdiction: St. Lucie County Zoning: RS-3 Lot # : 223 Block: APPLICATION INFORMATION Permit Number: 0804-0031 Activity Type: Other Permit Type: Building (Miscellaneous) CONTRACTOR INFORMATION Contractor Name: NEWMAN MICHAEL J I Business Name: PIONEER SCREEN COMPANY INC II Business Addr: 1682 SW BILTMORE ST City / State / Zil PORT ST LUCIE, FL 349 Page 1 Owner(s): Robert A Smith Application Type: Building Permit w/o subs Other Activity: ALUMINUM STRUCTURE W/CONCRETE Stories: 1 Automatic Sprinkler System? ❑ Fax Number 772-340-4626 REVIEWS AND COMMENTS Review Type Status Reviewed By Documents Missing Pending 04/03/2008 1 Comment NEEDS NOC WITH PICK UP Front Counter. Review Complete Audrey Humphrey Notified for Pickup Pending Date Started Date Complete Date Released 04/03/2008 04/03/2008 Plans Examiner Review Incomplete Joe Cicio 04/09/2008 04/09/2008 1 Comment Plot Plan and application state 18' x 19' structure " plans specify an 18' x 18' structure ??? ' Engineer to adjust plans or contractor to change plots and application Zoning Review Incomplete Lydia Galbraith 04/04/2008 04/04/2008 04/09/2008 2 Comment THE VALUE OF CONSTRUCTION IS GOING OVER THE $10,000 AS PER SF CONSTRUCTION COST SCHEDULE FROM THE INTERNATION CODE COUNCIL. THE PERMIT REQUIRES AN UPDATED SURVEY SHOWING THE PROPOSED SCREEN ROOM. SEE ALSO THE COMMENTS FROM THE PLAN REVIEWER ABOUT THE SIZE. TRANSMISSION VERIFICATION REPORT TIME 04/09/2008 10:32 NAME FAX TEL SER.# BROH5J320634 DATE DIME 04/09 10:32 FAX NO./NAME 93404626 DURATION 00:00:29 PAGE(S) 02 RESULT OK MODE STANDARD ECM ST LUCIE COUNTY BOARD OF COUNTY COMICIISSIONERS PUBLIC WORKS DEPARTMENT BUILDING & ZONING DIVISION FAX COVER SHEET FAX #: (772) 462-2522 PHONE #: (772) 462-1S53 DATE: NO. OF PAGES INCL. COVER: A7TN: RE. 0 SENDER: PHONE* LiQ9, 1 r q CAL � Lc" - t� x.,,, : 41 n �JL�E CMG ST. LUCIE COUNTY �< BUILDING & ZONING v 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 �OR`oA 462-1553 FILLED LANDS AFFIDAVIT 1, the undersigned, am the owner of the following described property: for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number , i acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, F shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this property, St. Lucie County -is neither obliged nor liable to provide, for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. I Property Owner Name Property wner Signature Date STATE OF FLORIDA, COUNTY OF U C ACKNOWLEDGED'BEFORE ME THIS DAY OF � , 2& 'BY WHO IS PERSONALLY *jOWN TO ME -OR WHO -HAS PRODUCED I AS IDENTIFICATION. Heu L SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY NOTARY PUBLIC TITLE COMMISSION NUMBER (SEAL) f • My Commission =5"13 �1 gores October 29, 2006 r `\ Thursday, Apr 03, 2008 10:47 AM j or eo� Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 03 April 2008 Job Address: 1006 SAEGER AVE Received By: humphreya Paid With: CK Paid By: PIONEER SCREEN CO INC II Building Receipt Receipt #: 0000061909 ermit Number: SLC- 0804-0031 Amount: $50.00 �redit Card Number: Check Number: 48625 Sign: DATE M N N H O LL_ O LEI z J F- in .1_ FND IR "NO CAP" 1.24'W b 0 roi FND I "LB 67S 0.13'E,0.9! 4' FENCE LLIINE_ —x 5' CHAIN LINK FENCE CORNER - 0.9'E OF PL IRON 5' CHAIN LINK FENCE CORNER 0.WE.0.6'N OF PCOR AFL DONED Co. L pate v it 4 do 5' CHAIN LINK FENCE INTERSECTIONl 0.2'N OF PL x 48.63' . 1 0 COVERED PORCH o FFE49.48 1 CBS STORY FFEa49.81 +50.00 ASSUMED '- Pq SITE BENCHMARK O 4.3'X4.3' 60D NAIL�ui CONC -511.16 D.z� I y 512.29' M1 FND NAIL HOLE 0.11'W,0.03'N Co NC DRIVE a N g 107. / B MAILBOX 107.23'(D) 107.49'(M) N89'37'03"W 1319.63:(D) 1319.18 ((M)) SAEGER AVENUE 30' R/W - 10' ASPHALT ROAD 4' CTIN LINK FENC CORNER 0.6'W,0.7'S OF PCOR "LB 6790" 0.17'E M N N O 3 I- O N O O p Ld z O O _ --I In I-_ N W C CHAIN LINK ON p� CORNER f X IRC 6790" 7'E 0 OI LO N 38.62'(D) 4D NAIL HOLE 0.15'W 662.62'(D) sa j- D ;+! W Q En II of ~ Cn - � U c UJ A C� SAEGER AVENUE LU z W Q W 0 z J O I LOCATION MAP NOT TO SCALE — CITY'WATER AND SEWER LEGAL DESCRIPTION: THE EAST 107.23 FEET OF THE WEST 618.38 OF THE NORTH 105.00 FEET OF THE SOUTH 130.00 FEE OF LOT 223 OF Q "WHITE CITY SUBDIVISION". ACCORDING TO THE PLAT Z THEREOF AS RECORDED IN PLAT BOOK 1. PAGE 23 OF THE w PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. > F J Q Q 2 a W a oil Z SURVEYORS NOTES \ o:a 1. UNLESS OTHERWISE NOTED ONLY PLATTED EASEMENTS ARE La SHOWN HEREON. 0 2. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE LOCATED UNLESS OTHERWISE SHOWN. 3. THIS SITE LIES WITHIN FLOOD INSURANCE RATE MAP ZONE X. 4. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE SURVEYOR AND IS PROVIDED AS A COURTESY. THE, FLOOD ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. 5. BEARINGS SHOWN HEREON ARE BASED ON THE EAST LINE OF . - LOT 223 AS BEING S00.02'26"W ACCORDING TO THE PLAT DESCRIBED HEREON. D PE FNIRON PI RONBOXP 7. ALL LOT DIMENSIONS SHOWN ARE PER PLAT UNLESS IN OTHERWISE NOTED. 1 69'W B. NOT VALID WITHOUT THE SIGNATURE AND, ORIGINAL RAISED SEAL OF A FLORIDA LISCENSED SURVEYOR AND MAPPER. PERM I' T 0804-0031 1006 SAEGER URVEY: BOUNDARY U C T I E I N UPDATE D ON: 12-05-06 12-05-06 4-16-08 AVENUE PLOT PLAN 4-16-08 LEGEND: (C) = CALCULATED (M) = MEASURED (P) = PLATTED CMP = CORRUGATED METAL PIPE CNS = COULD NOT SET CONC = CONCRETE FFE = FINISHED FLOOR ELEVATION FND =FOUND 5/8" IRON REBAR FINAL IRC = 5/B" IRON REBAR W,I TH PLASTIC CAP 5-23-08 PCOR PROPERTY CORNER PCP = PERMANENT CONTROL POINT PL = PROPERTY LINE PUDE = PUBLIC UTILITIES do DRAINAGEcEASEMEN R/W = RIGHT-OF-WAY R = RADIUS OF CURVE L = LENGTH OF CURVE SF = SQUARE FOOT =DELTA OF CURVE 0 = SET 5/8" IRON REBAR WITH PLASTIC CAP "AJP PSM 6330" CERT I F I ED TO: ROBERT A. SMITH A(f e I hereby certify that the sL;r'vc�y'sh.Dwn. heF3on is true and correct and is based on aa� ugol measeuremr,'nf'_'- taken in the field. This survey meats,'.Ehe;lrli.lYiinirn,,Tecli-rival Standards of Chapter 61G17 Florida.' a0rin,viltrat ive`cbds.'= rr = � •=r ALE XAf� Professional ,Su'rVeyor.,&•M-appr r Florida Cart if i.c a t eNJ'. 6330 ALEXANDER J. PIAZZA PSM, INC. Surveying •Mapping Consulting 619 SW Blltmore Street ® Port St. Lucie. Florida 34953 Phone: (772) 340-7770 LBFm Fax: (772) 340-2250 CAD K:\BUILDERS\DWG2006\DM06-504 REF K: \ F1D CJM F8. 30 PG. 17 JOB 06-0504� OFF CJM DATE 5 23-08 REVISIONS: BY.• CKD AJP SHEET 1 OF 1 DWG C-154 FND IF "LB 6791 0.13'E.0.95 4, FENCE LINE —x� RNER 5' CHAIN FENCE CO N 0.9'E OF PIL w N 0 0 N N n O P w z O 0 J Z H FND 1 2". PPE IRON FND IR "NO CAP" 1.24' W 5' CHAIN LINK FENCE CORNER 0.8'E,0.6'N OF PCOR SL S8 '37'02. 'rno ®HA�BLL DONED 48.63' m - _ o COVERED PORCH o N FFE=49.48 CB0 CIE S STORY FFE-49.81 CONC in DRIVE M Y Structure must me:: minimum setbacks 4' do 5' CHAIN LINK 4' CHAIN LINK FENCE INTERSECTION FENCE CORNER 0.2'N OF PL x 0.6'W.0.7'S OF POOR 13.08' �-18:00' m m� � O g ' 18:00 13.01' pROPOSE COVERE[ SCREEN RC PROPOSE FFE=49.4 (A 12.00' 32.19' ONC g 00 ASSUMEDtr 107.2;BENCHMARKCMP 60D NAIL,MAILBOX 511.16 D512.29' 07.23'(D) 107.49'(M) FND NAIL N89'37'03"W 1319.63' D HOLE 1319.18'(M� 011'W.0.03'N SAEGER AVENUE 30' R/W - 10' ASPHALT ROAD 1 1006 SAEGER AVENUE TYPE OF SURVEY: BOUNDARY U/C TIE IN UPDATE PLOT PLANT DATE: REVISIONS: "LB 6790" 0.17'E I M 14.35' N N I— C) �� 14 28' N O p O LJ Z_ OM O O J B � N t 4' CHAIN LINK w - ONN PL CORNER FND IRC "LB 6790" 0.17'E O OI Ld N —1 38.62'(D) FND NAIL HOLE 0.15'W LEGEND: 662.62'(D) FRONT SIDES CN SIDS REA Z N G TEe,H; LLJ m O Z Of H a 2 Q3 W OIL FND IRON PIPE IN BOXCUT 1.69'W (C) = CALCULATED PCP = PERMANENT CONTROL POINT (M) = MEASURED PL = PROPERTY LINE (P) = PLATTED PUDE = PUBLIC UTILITIES do DRAINAGE EASEMEI CMP = CORRUGATED METAL PIPE R/W =_ RIGHT—OF—WAY CNS = COULD NOT SET R = RADIUS OF CURVE CONC = CONCRETE L = LENGTH OF CURVE FIFE = FINISHED FLOOR ELEVATION SF = SQUARE FOOT FND = FOUND 5/8" IRON REBAR A = DELTA OF CURVE IRC = 5/8" IRON REBAR WITH PLASTIC CAP O = SET 5/8" IRON REBAR-WITH PLASTIC PCOR = PROPERTY CORNER CAP "AJP PSM 6330" ALEXANDER J. PIAZZA PSM, INC. JFLD `�u K:\BUILDERS\DWG2006\DWGO6-504 Surveying " Mapping " Consulting -REF K:\ 619 SW Biltmore Street BMG/AJP FB• 30 PG. 17 JOB 06-0504 ® Port St. Lucle, Florida 34983 Phone: (772) 340=7770 OFF BMG; DATE 4/ 16/ 08 ZBD Fax: (772) 340-2250 day. CKD AJP SHEET 1 OF 1 DWG C-149 W z En Q a: Lt SAEGER AVENUE LOCATION MAP -NOT TO SCALE — CITY WATER AND SEWER LEGAL DESCRIPTION: THE EAST 107.23 FEET OF THE WEST 618.38 OF THE NORTH 105.00 FEET OF THE SOUTH 130.00 FEE OF LOT 223 OF "WHITE CITY SUBDIVISION". ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 1, PAGE 23 OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. SURVEYORS NOTES UNLESS OTHERWISE NOTED ONLY PLATTED EASEMENTS ARE SHOWN HEREON. 2. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE LOCATED UNLESS OTHERWISE SHOWN. 3. THIS SITE LIES WITHIN FLOOD INSURANCE RATE MAP ZONE X. 4. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE SURVEYOR AND IS PROVIDED AS A COURTESY. THE 'FLOOD ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. 5. BEARINGS SHOWN HEREON ARE BASED ON THE EAST LINE OF LOT 223 AS BEING S00'02'26"W ACCORDING TO THE PLAT DESCRIBED HEREON. 7. ALL LOT DIMENSIONS SHOWN ARE PER PLAT UNLESS OTHERWISE NOTED. 8. NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LISCENSED SURVEYOR AND MAPPER. CERTIFIED TO: ROBERT A. SMITH I hereby certify thatK, h®~�'survey shbxn':hereon is true and correct and is based•o, act.�01,-measeurerihnts taken in the field. This survey-meetsY.'t'he Minirnun_=Technical Standards of Chapter 61G17 FI`orida adrnkn:strative-code. ALEXA'' R _J1 ,P,II Professional 'Survey'or & Mapper Florida Certificate No.: 6330 14138 PM EST DESIGN NOTES: I.ALL DIAGONAL BRACING SHOWN IN BOTH THE ROOF AND WALLS SHALL BE 2 x 2 x .093 TUBE MATERIAL. 2. 18 x 14 MESH SCREEN IS THE MAXIMUM ALLOWABLE DEN51TY FOR THIS ENCLOSURE'S DESIGN. 3, DOOR(5) MAY BE PLACED INTO ANY SCREEN WALL PANEL EXCEPT FOR THOSE THAT CONTAIN DIAGONAL BRACING. 1 1 I I PIONEER SCREEN CO., 11 SCREEN ROOF ENCLOSURE FOR: SMITH RESIDENCE 1006. SAEGER AVE. FT. PIERCE';, FLORIDA OVERALL DESIGN COMPLIES WITH THE 200(o AMENDMENTS TO THE F.B_C. 2004 BUILDING CODE, FOR 140 MPH WIND LOAD (3-5ECOND GUST), FOR EXPOSURE CATEGORY "B" TH15 SYMBOL. REPRESENTS DIAGONAL 0 WIND BRACING (IN BOTH THE ROOF AND WALLS), 2 x 2 x .093 TUBE MATL. 0 THI5 SYMBOL REPRESENTS BEAM SPLICE LOCATIONS E F J K cc EXISTING HOST 8TRUCTURE 6._0� 6 06 0 18' O' OVERALL WIDTH I x 2 x (TYP) x N N Ix2 1 6' 0' HEIGHT I T >w CONCEALED FASTENERS OR ATTACHMENTS m N ARE THE RESPONSIBILITY OF THE C'o �I u9Z CONTRACTOR OF RECORD � a o 0) K o G'N�N ooc W�NJ V cj : * STI LUCIE Co LL Z ¢ co O. BUILDING 4 Si0 U 2 0 REVII w � N W noQ Fa R Clr• r u? U REVIEWED 6Y ly ui m Z DATE o z w a. PLAN ND RldfT a. Ono MUST B KEPT ON JOB OR NO INSP CTION WILL BE MADE rn F45RIGATION i INSTALLATION REQUIRED GUIDELINES: NOTE: ANY JOBS THAT REQUIRE 51TE-5PECIFIC DE51GN / ENGINEERING MUST BE SUBMITTED TO THE ENGINEER OF RECORD FOR SUCH DE51GN CONSIDERATION PRIOR TO THE JOB BEING PERMITTED, FABRICATED OR INSTALLED. LEAD-TIMES FOR SUCH WORK WILL DEPEND ON OUR CURRENT WORK LOAD AT ANY GIVEN TIME. THE ITEMS BELOW ARE NOT PERMITTED ON ANY ENCLOSURE WITHOUT 5ITE-5PECIFIC DE51GN 4 AUTHORIZATION FROM THE ENGINEER OF RECORD. MINIMUM FOOTER T45LES 12' 16' x 16° WITH 44' TO 52' I. NO SCREEN ROOF BEAMS SHALL DE LOCATED WITHIN 12-INCHES OF ANY OUTSIDE CORNER OF ANY WALL, FASCIA OR STRUCTURAL GUTTER. 2. NO CABLE BRACING SHALL BE USED ON ANY ENCLOSURE AT ANY TIME FOR THE RESISTANCE OF ANY IMPOSED DESIGN LOADING. IF A JOB EXCEEDS THESE PARAMETERS, THE FOUNDATION 3. THERE SHALL BE NO SUBSTITUTION OF EITHER CONCRETE ANCHOR TYPE OR MUST BE 61TE-6PECIFICALLr DESIGNED 13Y THE ENGINEER MANUFACTURER OTHER THAN THOSE SPECIFIED ON THESE ENGINEERED DESIGN MONOLITHIC FTG. LOAD CAPACITIES ARE BASED DRAWINGS. MIN. OF 3 FEET OF CONT. CONCRETE, 2,500 PSI 4. THERE SHALL BE NO SCREENING UTILIZED THAT IS FINER THAN 18 x, 14 MESH CONCEALED FASTENERS OR ATTACH UM, W/ WIRE OR FIBERMESH REINFORCEMENT SCREEN WITHOUT SITE -SPECIFIC DESIGN (THAT SHALL BE DONE PRIOR TO THE ARETHERESPONSIEILiTYOFTHE JOB BEING FABRICATED OR INSTALLED) WITH JOB DRAWINGS BEARING THE ENGINEER OF RECORDS ORIGINAL SIGNATURE (IN BLUE INK) UNDER HIS EMBOSSED SEAL. 5. ALL SCREEN ROOF ENCLOSURES MUST BE POSITIONED ON THE EDGES OF THE CONCRETE DECK SO THAT THE OUTER SURFACE OF THE SCREEN FRAME IS NO LESS THAT 2 3/4 - INCHES IN FROM THE EDGE, TO CREATE PROPER EDGE DISTANCE FOR THE SPECIFIED CONCRETE ANCHORS AT THE BASE OF EACH COLUMN. G. ALL ROOF FIUR41NS IN THE ROOF AND CHAIR RAILS IN THE WALLS SHALL NOT EXCEED 8-FEET CENTER - TO - CENTER SPACING (SEE APPROPRIATE DETAILS ON OTHER SHEETS OF THIS DRAWING FOR SPECIFIED MATERIAL SIZES REQUIRED FOR ANY GIVEN APPLICATION. 1. NO SCREEN ROOF ENCLOSURE SHALL BE. INSTALLED UTILIZING SEVEN-INCH STRUCTURAL GUTTER, AS IT IS NOT PERMITTED, OR STRUCTURALLY ADEQUATE UNDER THIS'ENGINEERING. CONTRACTOR OF RECORD THE ITEMS BELOW MUST ISE 5URMITTED TO THE ENGINEER OF RECORD PRIOR TO MEASURING .4 LAYOUT, FABRICATION OR INSTALLATION FOR THE REQUIRED SITE -SPECIFIC DESIGN. 1. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES ROOF BEAMS THAT EXCEED 40-FEET IN SPAN, AT ANY POINT ON THE ENCLOSURE. 2. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES WALL COLUMNS (UPRIGHTS) THAT EXCEED 12-FEET IN HEIGHT AT ANY POINT ON THE ENCLOSURE. 3. ANY ENCLOSURE THAT UTILIZES ANY CARRIER BEAM (A. BEAM THAT ACTS AS SUPPORT FOR_ANY OTHER SCREEN ROOF BEAM) AT ANY POINT ON THE ENCLOLSURE. NO CARRIER 15EAM SHALL BE PERMITTED TO BE MOUNTED TO THE FASCIA OF ANY HOST STRUCTURE (AS PRIMARY SUPPORT). 4. INSTALLATION OF ANY SCREEN ROOF ENCLOSURE ON AN EXISTING HOUSE FASCIA.WHERE THE OVERHANG EXCEEDS 2-FEET. NOTE THAT IF THE EXISTING RESIDENCE WAS CONSTRUCTED UNDER ANY BUILDING CODE PRIOR TO F.B.C. 2001, THE JOB MAY REQUIRE FOURTH -WALL TYPE CONST., AS THERE IS NO WAY TO CERTIFY THE ABILITY OF A HOST STRUCTURE THAT WAS ONLY BUILT TO WITH- STAND 110 MPH WIND LOADS OR LESS, (AS WAS REQUIRED UNDER PREVIOUS BUILDING CODES) TO RESIST THE IMPOSED LOADS OF AN ENCLOSURE THAT IS DESIGNED TO WITHSTAND THE LOADS IMPOSED UNDER THE 140 MPH WIND LOAD SPECIFIED IN THE CURRENT BUILDING CODE. SNAP / LAP JOINT CONNECTION NOTE: II ALL FRAMING MEMBERS ON ANY ENCLOSURE THAT UTILIZE SNAP OR LAP JOINT IN THEM SHALL HAvE 012 TEKS INSTALLED THRU THE SNAP OR LAP CONNECTION AT IS INCHES ON CNTR. (TYP). THESE TEK SCREWS ARE TO BE PLACED ON BOTH EDGES OF THE UPRIGHT (BOTH THE INNER AND THE OUTER EDGE) IN ALL CASES. THIS SPECIFICATION APPLIES TO UPRIGHTS AND BEAMS BOTH. (°ISOLATED FOOTERS MAY BE USED ON EDGE OF EXIST. CONC. SLAB OR UNDERNEATH THE PERIMETER OF BRICK PAVER DECK (ALL SIDES) THE ENGINEER Or RECORD WILL NOT BE ABLE TO CERTIFY THE STRUCTURAL INTEGRITY OF ANY EXISTING CONCRETE DECK / FOOTINGS THAT WERE INSTALLED WITHOUT PERMITS, AS THERE, WOULD-BE. NO RECORDS TO VERIFY CONCRETE THICKNESS', FOOTER SIXES AND THE SIZE AND QUANTITY OF STEEL RE -BARS THAT WOULD BE REQUIRED UNDER. THE CURRENT BUILDING CODE STANDARDS, SCREW SPACING AND EDGE DISTANCE 5IPEC.'5 THIS TABLE IS BASED ON THE PROPERTIES OF C-1022 LOW CARBON STEEL 5MS AND SELF -DRILLING (TEK) SCREWS, WHICH ARE AN INDUSTRY STANDARD SCREW. NOMINAL' 5CRW CW MIN. EDGE MIN. CENTER-TO- SREW SIZE DIAMETER (IN.) 016TANCE CENTER DISTANCI= a8 0.156 5/16° 1/10° 10 0.188 3/8' 1/2' 012 0.219 1/2' S/8' 014 0.250 5/8' 3/4' INTERNAL. CONNECTION SPECIFICATION (UTILIZING SCREW 5055E5) ALL INTERNAL GONNECTIONS UTILIZING THE EXTRUDED SCREW 8055E5 SHALL HAVE 010 5M5 SCREWS, WITH A MINIMUM EMBEDMENT INTO THE SCREW 5055 OF 1 3/4" (UNLESS OTHERWISE SPECIFIED ON ANY CONNECTION DETAIL). ALL SCREW BOSSES IN A GIVEN EXTRUSION MUST BE FILLED (EXAMPLE: THE 2 x 3 x .010 CHAIR RAIL / ROOF PURLIN THAT HAS SIX SCREW BOSSES, MUST HAVE 81X OF THESE #10 SMS SCREWS INSTALLED AT EACH END OF THAT COMPONENT, AT EACH CONNECTION). SCREEN PANEL INSTALLATION 5PECIFICATION: PLEASE NOTE THAT ALL SCREEN PANEL OPENINGS IEOTH ROOF AND WALLS) SHALL BE INSTALLED ON ALL FOUR SIDES WITH SPLINE (INDEP- ENDANT OF ALL SURROUNDING PANELS). THE ONLY FRAMING COMPONENTS THAT ARE -NOT REQUIRED TO HAVE SPLINE INSTALLED IN THEM ARE ALL OF THE DIAGONAL WALL AND ROOF BRACING, CONCRETE ANCHOR SPECIFICATIONS, ALL CONCRETE ANCHOR5 SPECIFIED ON TH15 DETAIL SHEET ARE MANUFACTURED BY 'RED HEAD' ANCHORING SYSTEMS, AS ALL LOAD CAPABILITIES ARE BASED ON TEST DATA FURNISHED BY RED HEAD IN THEIR PRODUCT AND RESOURCE BOOK. NO SUBSTITUTIONS OF ANY OTHER MANUFACTURER'S CONCRETE ANCHORS IS PERMITTED WITHOUT SUBMITTAL OF THE COMPANY'S TEST DATA (TO VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN, SIGNED AND SEALED LETTER OF AUTHORIZATION FROM THE ENGINEER OF RECORD, ANY UNAUTHORIZED ANCHOR SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH TH16 DESIGN. THE ANCHORS TO BE USED FOR APPLICATIONS SPECIFIED IN THI6 ENGINEERING DESIGN PLAN ARE AS FOLLOWS: mmmo® 1/4' DIA FASTENERS: RED HEAD ITW TAPCON (SEE INDIVIDUAL DETAILS FOR MINIMUM. EMBEDMENT DEPTH INTO CONCRETE) 3/6' DIA. FASTENERS: 3/8' TRU BOLT WEDGE ANCHOR (SEE INDIVIDUAL DETAILS FOR QUANTITY OF FASTENERS NEEDED) (MINIMUM EMBEDMENT SHALL BE 3' INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) DESIGN DISCLAIMER 3/6' LARGE DIAMETER TAPCON (LOT) (SEE INDIVIDUAL DETAILS FOR QUANTITY OF FASTENERS NEEDED) (MINIMUM EMBEDMENT SHALL BE 21121 INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) FOR BRICK PAVER INSTALLATION: FOR INSTALLATION ON A BRICK PAVER DECK, THE ONLY FASTENERS THAT WILL MEET THE DESIGN CRITERIA INDICATED WITHIN THESE DE51GN SPEC.'S ARE THE RED HEAD .TRU BOLT WEDGE ANCHOR (3/8' x i'), WHICH BASED ON 1/8' ANGLE, I x 2 O.B., 2114' THICK BRICK PAVER AND A MAXIMUM MORTAR BED THICKNESS OF 3/4'. THIS SCENARIO WILL STILL MEET THE MINIMUM FASTENER EMBEDMENT. IF ANY OF THESE CONTRIBUTING FACTORS EXCEED THE DIMENSIONAL BREAKDOWN INDICATED, THE JOB MUST BE PRESENTED TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC ANCHORING DESIGN. EXIST. HOUSE FASCIA NOTES: IT SHALL BE THE RESPONSIBILITY OF THE ,INSTALLING CONTRACTOR TO INSPECT AND INSURE THE CONDITION OF THE EXISTING F45CIA, TO DETERMINE IF IT 15 IN GOOD ENOUGH CONDITION TO SUPPORT THE PROPOSED SCREEN ENCLOSURE (PRIOR TO ITS INSTALLATION) THERE IS NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IN THIS ENGINEERING DESIGN DOCUMENT REGARDING THE ABILITY OF ANY H05T STRUCTURE TO RE515T THE BUILDING CODE SPECIFIED DESIGN LOADS IMPOSED BY ANY PROPOSED SCREEN ENCLOSURE. SUCH CERTIFICATION WILL BE DEPENDENT ON AVAILABILITY OF ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS, AS WELL AS ORIGINAL PERMIT AND INSPECTION RECORDS FOR THE H05T STRUCTURE, CERTIFICATION OF THE HOST STRUCTURE, IF IT 15 REQUIRED, WILL ULTIMATELY BE POSSIBLE ONLY IF THESE RECORDS CONTAIN ALL THE INFORMATION NEEDED BY THE ENGINEER TO PERFORM ALL OF THE NECESSARY ANALY515 TO DETERMINE IF SUCH CERTIFICATION 15 EVEN POSSIBLE. Ld W o Uj z 0- lid.. � Lu 0 LU �.. co w cD VL . INTERNAL. CONNECTION SPECIFICATION (UTILIZING SCREW 5055E5) ALL INTERNAL GONNECTIONS UTILIZING THE EXTRUDED SCREW 8055E5 SHALL HAVE 010 5M5 SCREWS, WITH A MINIMUM EMBEDMENT INTO THE SCREW 5055 OF 1 3/4" (UNLESS OTHERWISE SPECIFIED ON ANY CONNECTION DETAIL). ALL SCREW BOSSES IN A GIVEN EXTRUSION MUST BE FILLED (EXAMPLE: THE 2 x 3 x .010 CHAIR RAIL / ROOF PURLIN THAT HAS SIX SCREW BOSSES, MUST HAVE 81X OF THESE #10 SMS SCREWS INSTALLED AT EACH END OF THAT COMPONENT, AT EACH CONNECTION). SCREEN PANEL INSTALLATION 5PECIFICATION: PLEASE NOTE THAT ALL SCREEN PANEL OPENINGS IEOTH ROOF AND WALLS) SHALL BE INSTALLED ON ALL FOUR SIDES WITH SPLINE (INDEP- ENDANT OF ALL SURROUNDING PANELS). THE ONLY FRAMING COMPONENTS THAT ARE -NOT REQUIRED TO HAVE SPLINE INSTALLED IN THEM ARE ALL OF THE DIAGONAL WALL AND ROOF BRACING, CONCRETE ANCHOR SPECIFICATIONS, ALL CONCRETE ANCHOR5 SPECIFIED ON TH15 DETAIL SHEET ARE MANUFACTURED BY 'RED HEAD' ANCHORING SYSTEMS, AS ALL LOAD CAPABILITIES ARE BASED ON TEST DATA FURNISHED BY RED HEAD IN THEIR PRODUCT AND RESOURCE BOOK. NO SUBSTITUTIONS OF ANY OTHER MANUFACTURER'S CONCRETE ANCHORS IS PERMITTED WITHOUT SUBMITTAL OF THE COMPANY'S TEST DATA (TO VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN, SIGNED AND SEALED LETTER OF AUTHORIZATION FROM THE ENGINEER OF RECORD, ANY UNAUTHORIZED ANCHOR SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH TH16 DESIGN. THE ANCHORS TO BE USED FOR APPLICATIONS SPECIFIED IN THI6 ENGINEERING DESIGN PLAN ARE AS FOLLOWS: mmmo® 1/4' DIA FASTENERS: RED HEAD ITW TAPCON (SEE INDIVIDUAL DETAILS FOR MINIMUM. EMBEDMENT DEPTH INTO CONCRETE) 3/6' DIA. FASTENERS: 3/8' TRU BOLT WEDGE ANCHOR (SEE INDIVIDUAL DETAILS FOR QUANTITY OF FASTENERS NEEDED) (MINIMUM EMBEDMENT SHALL BE 3' INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) DESIGN DISCLAIMER 3/6' LARGE DIAMETER TAPCON (LOT) (SEE INDIVIDUAL DETAILS FOR QUANTITY OF FASTENERS NEEDED) (MINIMUM EMBEDMENT SHALL BE 21121 INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) FOR BRICK PAVER INSTALLATION: FOR INSTALLATION ON A BRICK PAVER DECK, THE ONLY FASTENERS THAT WILL MEET THE DESIGN CRITERIA INDICATED WITHIN THESE DE51GN SPEC.'S ARE THE RED HEAD .TRU BOLT WEDGE ANCHOR (3/8' x i'), WHICH BASED ON 1/8' ANGLE, I x 2 O.B., 2114' THICK BRICK PAVER AND A MAXIMUM MORTAR BED THICKNESS OF 3/4'. THIS SCENARIO WILL STILL MEET THE MINIMUM FASTENER EMBEDMENT. IF ANY OF THESE CONTRIBUTING FACTORS EXCEED THE DIMENSIONAL BREAKDOWN INDICATED, THE JOB MUST BE PRESENTED TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC ANCHORING DESIGN. EXIST. HOUSE FASCIA NOTES: IT SHALL BE THE RESPONSIBILITY OF THE ,INSTALLING CONTRACTOR TO INSPECT AND INSURE THE CONDITION OF THE EXISTING F45CIA, TO DETERMINE IF IT 15 IN GOOD ENOUGH CONDITION TO SUPPORT THE PROPOSED SCREEN ENCLOSURE (PRIOR TO ITS INSTALLATION) THERE IS NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IN THIS ENGINEERING DESIGN DOCUMENT REGARDING THE ABILITY OF ANY H05T STRUCTURE TO RE515T THE BUILDING CODE SPECIFIED DESIGN LOADS IMPOSED BY ANY PROPOSED SCREEN ENCLOSURE. SUCH CERTIFICATION WILL BE DEPENDENT ON AVAILABILITY OF ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS, AS WELL AS ORIGINAL PERMIT AND INSPECTION RECORDS FOR THE H05T STRUCTURE, CERTIFICATION OF THE HOST STRUCTURE, IF IT 15 REQUIRED, WILL ULTIMATELY BE POSSIBLE ONLY IF THESE RECORDS CONTAIN ALL THE INFORMATION NEEDED BY THE ENGINEER TO PERFORM ALL OF THE NECESSARY ANALY515 TO DETERMINE IF SUCH CERTIFICATION 15 EVEN POSSIBLE. Ld W o Uj z 0- lid.. � Lu 0 LU �.. co w cD VL . GENERAL N®TE5 AND DE51GN PARA ETER& I. THE OVERALL DESIGN COMPLIES WITH THE 2006 AMENDMENT TO THE FLORIDA BUILDING CODE 2004 (CHAPTER 16 AND 20), AND 15 BASED ON THE FOLLOWING PARAMETERS: A. WIND SPEED: 140 M.P.H., 3-SECOND GUST B. EXPOSURE CATEGORY 'B' C. DESIGN PRESSURES A5 FOLLOWS: a) SIMULTANEOUS WIND LOADING a (6-F.S.F. FOR SCREEN ROOF AND 21 p.SF. FOR SCREEN WALLS b) 300 LB LOAD APPLIED VERTICALLY DOWNWARD ALONG ANY ONE FOOT (12-INCHES) OF ANY PRIMARY MEMBER (EXCLUDING DIAGONAL WIND BRACING, WHICH 15 TREATED A5 A 'STRUCTURAL MEMBER' UNDER 2006 AMENDMENT DEFINITIONS. D. MAXIMUM ENCLOSURE HEIGHT SHALL NOT EXCEED 30-FEET E. ALLOWABLE DEFLECTION OF 'L / 60', AS SPECIFIED I TABLE P1610.1, FOR NON -HIGH VELOCITY HURRICANE ZONES. F, CONTINUOUS LOAD PATH IS PROVIDED, 2. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD): A. ALL EXTRUSIONS SHALL BE ALUMINUM ALLOY %063-T6 (NOTE THAT THE SPLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALLOY 06061-Tb, IF THIS MATERIAL 15 MORE READILY AVAILABLE TO THE CONTRACTOR) (SEE COMPONENT SHAPES AND SIZES AT RIG -HT). B. FASTENERS SHALL 15E ALUMINUM ALLOYS 2024-T4 4 1015-T6„DOUB1I_F CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL, OR 300-SERIE5 STAINLESS STEEL. IT IS THE RESPONSIBILITY OF' THE CONTRACTOR TO PROVIDE THE APPROPRIATE MEANS FOR SEPARATION OF DISSIMILAR MATERIALS A5 THEY ARE DEFINED IN SECTION *20038.4. THE CONTRACTOR MAY IMPLEMENT ANY OF THE MEANS SPECIFIED IN THIS SECTION. ANY ALTERNATIVE MEANS MUST BE ACCOMPANIED BY A LETTER OF CERTIFICATION FROM THE PRODUCT'S MANUFACTURER (THIS LETTER MUST BE SIGNED AND SEALED BY A FLORIDA LICENSED STRUCTURAL ENGINEER), WHICH STATES THAT THEIR PRODUCT MEETS / EXCEEDS ALL OF THE REQUIREMENTS SPECIFIED IN THE ABOVIE- LISTED SECTION. THIS LETTER SHALL ALSO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD FROM BD.Q., INC. C. SCREEN CLOTH SHALL BE VINYL COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 x 14 (58% OPEN). 3. ALL FASTENERS THAT PASS THROUGH ANY EXTRUSION INTO CONCRETE, MASONRY, WOOD, STEEL, ALUMINUM OR ANOTHER EXTRUSION SHALL HAVE A 5/8-INCH DIAMETER WASHER, MINIMUM.(UNLE65 OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD), AND SHALL BE NO MORE THAN IS -INCHES CENTER - TO - CENTER SPACING. 4. ALL FASTENERS ADJACENT TO UPRIGHTS THAT DO. NOT REQUIRE REINFORCING ANGLE CLIPS, SHALL BE PLACED WITHIN TWO (2) INCHES OF THAT UPRIGHT (TYP. FOR BOTH SIDES). D. SCREEN DOORS) MAY Be LOCATED IN ANY SCREEN WALL PANEL, EXCEPT FOR TH06E THAT CONTAIN piA60NAL WIND 5RA:iNG CK-BRACING'). ALL DOORS SHALL BE SELF -CLOSING AND SELF -LATCHING. DOORS INSTALLED IN AN ENCL05URE THAT SURROUNDS A POOL / SPA SHALL HAVE DOOR LATCHES INSTALLED FIvE (5) FEET ABOVE THE FLOOR, MINIMUM. " 6. COPIES OF THIS ENGINEERING SPECIFICATION / DESIGN DETAIL ARE TO ONLY BE CONSIDERED VALID FOR PERMITTING OR DE516N CERTIFICATION PURPOSES WHEN ALL SHEET5 OF ANY SUBMITTED SET BEARS THE ENGINEER'S ORIGINAL SIGNATURE (IN BLUE INK), UNDER H15 EMBOSSED SEAL. B.D.Q., INC. SHALL NOT BE RESPONSIBLE FOR NON -ORIGINAL COPIES THAT ARE SUBMITTED, THAT HAVE ANY UNAUTHORIZED CHANGES, ALTERATIONS OR DELETIONS ON THEM. 1. THESE ENGINEERING DETAIL DRAWINGS ARE ONLY VALID IF THE DATE ACCOMPANYING THE ENGINEER'S ORIGINAL SIGNATURE IS LESS THAN W DAYS OLD. NO BUILDING OFFICIAL OR BUILDING DEPARTMENT SHOULD ACCEPT COPIES THAT ARE OLDER THAN THIS, AND SHOULD REQUEST THE SUBMITTING CONTRACTOR OBTAIN UPDATFD / CURRENT ENGINEERING. 6. ALL ENGINEERING SPECIFICATIONS AND DETAIL DRAWING CONTAINED WITHIN TH15 ENGINEERING DOCUMENT ARE THE SOLE PROPERTY OF B.D.Q., INC. ANY UNAUTHORIZED COPYING OR OTHER REPRODUCTION IN PART OR WHOLE OF THESE DOCUMENTS WILL NOT BE PERMITTED AND WILL BE PROSECUTED TO THE FULLEST EXTENT ALLOWED BY LAW. S, THERE SHALL BE NO REDISTRIBUTION OF THESE ENGINEERING DOCUMENTS BY THE PER60N OR COMPANY THAT ORIGINALLY PURCHASED SIGNED AND SEALED COPIES FROM B.D.Q., INC., WITHOUT EXPRESS WRITTEN AUTHORIZATION FROM B.D,Q., INC., AND THE ENGINEER OF RECORD. WALL COLUMN SCHEDULE (ALLOW. COLUMN HEIGHTS VS. WALL PANEL WIDTH) U80 MAX. ALLOWABLE DEFLECTION (140 MPH, EXP. °S", 21 P.S.F. DESIGN LOAD) DIMENSION COLUMN HEIGHT VS WALL PANEL WIDTH (SIGN PRESSURE = 21 Psi SIZE Tf I Tw 8' 0' T 6" 7' O' 6' 6' 6' 0" 5' 6' 5' 0' 4' 6' N (r 2x4 L .100 1 .045 1' 5' 1' 8' 8' 0' 8' 3' 8' 1' SIC' 9' 5' 9' II' 10' 5' 2x5 L A16 AM 9' 0' 9' 4' 9' 8' 10, 0' 10' 5' 10111, II' 5' 12' 0' 12' 9' 24 L .120 .050 9' 4' V 8' 10' 0' 10' 5' 10' 9' 11' 3' IF10' 12' 5' 13' 2' W L .120 .057 102' 106' 10II' 11' 3' II' 9' 12' 3' 12' 11' 13' 6' 14' 4' 2x8 L •224 .072 12' 6' 1 12' II' 1 13' 3' IV 14' 4' 15,01 18'10' 19' I0' 21' 0' .209 .072 15' 0' IV 1' I6' I' 11' 4' 18' 2' IV 0' 2m' 0' 21' 2' v2xIOL .306 . .082 IS' 1' ITT 19' II' j^24"d4l�' 21'.5' 22' 4' 23' 5' 24' 8' 26' 2' .389 .092 22' 0' 22' 9' 23' 6' 25' 4' 26' S' 1l' 8' 29' I' 30' 9' TF COIFONENT 5HAPE5 AND 5PECIFICATION5 m93 Tw .044 .040 10 "fl ;r, .010, 3' 2' 2' II II b 3� , ,-I I x 3 OB. I x 2 o.r3. a 2 x 2 x .093 TUBE �--a- THE ACTUAL VALUES FOR 'TF" FLANGE THICKNESS) AND 'Tw' (WM THICKNESS) FOR THE VARIOUS pIACx. RRAG�NCx 5ELF-MATING CV) SIZE SELF -MATING MATERIAL ARE INDICATED ON THE UPRIGHT HEIGHT AND BEAM SPAN TABLES. w z E& 11^&.r Q1rC11/-T11CC (MITI I H05T STRUCTURE WITH STRUCTURAL GUTTER MANSARD ROOF BEAM SPAN lu w MAN5ARQ REAM 5PAN5 ARE BASED = ON A MAXIMUM SPLICE ANGLE OF 30' ..a FOR HALF -MANSARD BEAM SPANS, USE vALUES SHOWN IN 'MANSARD BEAM SPAN TABLE (SAME MAX. SPLICE ANGLE (30°) APPLIES TO HALF -MANSARD BEAMS) mw d HOST STRUCTURE WITH n STRUCTURAL GUTTER PEAK / BEAM SPANS AND COLUMN SIZES ON THIS SHEET ARE RASED ON SIMULTANEOUS LOADING, AS DEFINED IN TABLE P1002.4, F.B.C. 2004, FOR 140 MPH WINDS, FOR EXPOSURE CATEGORY 'B' (21 P.S.F. WALLS, 6 P.5F, ROOF, 3001-5 CONCEN. LOAD) FLAT (SIMPLE) ROOF BEAM SCHEDULE MR RAT MNIS, LAM wx.(140MPH, B aV) DIME tVSIONd I ROOF PANEL WIDTH va BEAM SPA! (FOR MAX. WALL HEIGHT OF 18' 01 SIZE Tf Tw V 0" T E° 7' W 0 6' 9 O" 5' 6' S On 4' 6' 4' 0" 2X4 L .100 .045 w v w 3' w v 14' 4' 15' 0' 15' 8' W 5' IT 4' •IT 11' 2x5 L Ale .050 15' 9' IV 4' IT01' IT 8' IS 4' 19' 2' 20' 2' 21' 3' 22' T 2X6 L .120 .= 16' 4' IT O' Il' 1' 18' 2' 19' 0' IV II' 20' 9' 22' 0' 23' 3' W L .120 1 .057 16' 0' 18' 5' 19' 2' 19' 11' 208" 21' 8' 22 9' 24' 0' 25' 4' 2x8 L M .072_ 22' 0' 22' 8' 1 2515' 24' 4" 25' 4' 1 26' S' 1 2T 8' 29' 2' 30, V 24 L ) 209 .072 26' 9' 21' 1' 26' 6' MIT 30' 9' 32' 2' 1 33' 8' BF4' 31' 5' W L (H) .308 .082 DI V 34' 3' 3515, 3(0' 1' 38' 2' 3V 9° 41' 1' 43' 1' 4,.'2' 2X10 L .389 .092 39' 2' 40' 4' 41' 1' 43' 2' 44' 9' 46' 1' 1 48' 1' 51' 0' 53' 9' 0) REPRESENTS SPAN VALUES THAT ARE DEFLECTION -LIMITED JBEAM SPAN CALCULATION NOTE: THE SPANS IN THESE TABLES ARE BASED ON BOTH THE HOST STRUCTURE MOUNTING POINT AND WALL HEIGHT BEING THE SAME MEASUREMENT MANSARD / CEDER PEAK (GABLE) ROOF BEAM SCHEDULE im mAx. (140 MPH, EW.-M "THIS SPM TABLE IS LIMITED TO A. MAXIMUM VERTICAL RISE OF 3' w wow ROOF PANEL)MDTH va BEAM SPAN (FOR MAX. WALL HEIGHT OF IT 01 SIZEDIMENSION Tf T-h 8' 0' 7' IP T O' V 6° V O' 660 5' 0" 4' 6' 4' 0" 2x5 L 116 450 8' 6' 10,611 12' 1' 2x6 L .120 .050 Im' m' n' Im' 14- m' 16' m' 2X7 L .120 .057. 8' 3' 10' 0' 11' 8' 13' 4' IV 2' IT m' 15'2' 2X8 L .224 .072 14' 0' 15' 2' IV 4' 11' 9' 19' 2' 20' 1' 22' 4' 24' 31 26141 2X9 L (L) 209 .072 20' 9' 22' 0' 23' 2' 24' 6' 26' 0' 21' 1' 29' 6' 31' 5' 33' II' W L (H) .306 .082 2V 9' 30' 1' 31' S' 32' 11' 34' 6' 36' 4' 38' 6' 40' 8' 43' 6' 2X10 L 35' 8' 31' 2' 3V 9;" 40' V 42' 0' 1 44' 2' 46' 3' 1 48' II' 1 51' 8' MANSARD I CENTER PEAK GABLE ROOF BEAM SCHEDULE Lm wx. (14a MPH, EXP.'n *'MIS SPAN TABLE IS LIMITED TO A MAXIMUM VEWICAL RISE OF 3' 0" (36T DIMENSION ROOF PANEL WIDTH va BEAM SPAN (FAR MAX. WALL HEIGHT OF IT 01 SIZE Tf Tw 8' 0' 7' v 7' 0' V W V Oat 6 ®' S' (r 4' 6' 4' 0' 2x5 L .116 .050 4-8 L .120 .050 SIC,. 0(7 L .120 .057 II' m' 14' 2' 2x8 L .224 .072 8' 0' 10' 2' IT 2' 14' 3' I 3' 18' 4' 20' 1' 23' 2' 2x9 L (L 209 .072 16' 2' 11' 1' 19' 2' 201131 22' 6 24' 5' 26' 6' WIT 31' 5' 24 L H .308 .082 MIT 2' 28' 1' 30' 3' 32' V 34' 2' 36' 3' MIT 41' 6' 2x10 L 092 33' 3' E' ' V 36' 5' 38' 2' 40' 1' 42' 3' 44' 1' 41' 2' 49' II' MANSARD / CENTER PEAK (GABLE) ROOF BEAM SCHEDULE Lea mAx (14Q MPH, EV.'n '`'MIS SPAN TABLE IS LIMITED TO A (MAXIMUM VERTICAL RISE OF Tf (3T)' DIMENSION ROOF PANEL WIDTH va BEAM SPAN (FOR MAX. WALL HEIGHT OF IV 01 SIZE Tf Tw 8' 0" 7' 6' 7' O' 8' 6' 6' (' Sir Y (' N 6' 4' 0" 2x7 L .120 .057 2X8 L .224 .072 Im' 0' 13' 2' I6' 3' IS' 4' 2x9 L L) Mg .072 9' 4' II' 9' 14'0' 16' 3' 18' 5' 20' 1' 23' 2' 25' 9' 18' 8' 2X9 L (H .308 .082 22' 2' 23' 8' 25' 6' 21' 5' 29' S' 31' 6' 33' 11' 36' 6' 3V 1' 2x10 L •092 30' 6' 32' V 34' 0' 35' II' 31' 11' 40' 2' 42' 8' 4V 5' 48' 8' MANSARD DFAM SPANS OF LESS THAN 8' 0' ARE OMITTED FROM THIS TABLE ILL ® w IIR v LM Z I. LL ow o 0�.°v coLu 0' m 8 INDICATES -INDICATES WALL PANEL THAT SHALL HAVE DIAGONAL "K"-BRACING IN IT UP TO 8' WALL HGHT 6' TO 12' WALL HGHT •. �PA7,_ EE4o ►\marm, ����' 16' TO 24' BEAM SPAN 24' TO 32' BEAM SPAN 32' TO 40' BEAM SPAN o 'u F4, i 0 m , i EXIST. HOST STRUCTURE EXIST. HOST STRUCTURE NUMBER OF PANELS VARIES M 0 0 Ell II■■� imammEMS EXIST. HOST STRUCTURE TOTAL NO, OF BAYS VARIE$ THREE l3) RAYS ON EACH END OF OUTER -MOST WALL SHALL HAVE DIAL. BRACING EXIST. HOST STRUCTURE TOTAL NO. OF GAYS VARIES THREE (3) BAYS ON EACH END OF OUTER -MOST PANELS AND TWO e2) PANELS IN SECOND OUTER -MOST (SOW OF PANELS SHALL HAVE THE DIAGONAL BRACING (AS SHOWN) THE BRACING SCHEMATICS SHOWN ABOVE ARE THE SAME BRACING CONFIGURATION, REGARDLE65 of ROOF TYPE (MANSARD, PEAK, DOME, FLAT, ETC.) DESIGN NOTES: ALL DIAGONAL BRACING, USED EITHER--IN-THE ROOF - OR AS 'K'-BRACING IN THE WALLS SHALL BE 2' x 2' x .093 WALL THICKNESS TUBE, AND SHALL BE CUT TO FIT SNUG, WITH NO PLAY OR SHIFT IN THE BRACING. SEE DETAILS AT RIGHT FOR CONNECTION SPECIFICATIONS DESIGN NOTE: ALL THRU-BOLT5 PASSING THROUGH ANY ALUMINUM MATL. WITH A WALL THICKNESS LESS THAN •090, SHALL HAVE A Isis -INCH (OUTSIDE DIA.) FENDER WASHER (SEE GENERAL NOTE *2 ON SHEET REGARDING SEPARATION OF DISSIMILAR METALS). THE CONTRACTORS MAY, IF THEY CHOOSE, INSTALL THE ANGLE CLIPS FOR THE DIAGONAL TUBE BRACING (WHERE IT ATTACHES TO THE SELF - MATING SCREEN ROOF ]BEAMS) WITH THE THRU-BOLTS ONLY PASSING THROUGH -ONE-HALF OF THE_BEA_M. THIS_I.3_A_5TRUCTURALLT_AD QUAT_ ALTERNATIVE, AND WILL PERMIT INSTALLATION OF THESE ANGLE CLIPS IN THEIR SHOP, DURING FABRIGATION (PO56I5LY SAVING TIME DURING INSTALLATION IN THE FIELD). 0 UPPER ANGLE CLIP TO BE PLACED AT SAME ANGLE AS THE MANSARD LEG OF THE SCREEN ROOF BEAM 2 x 3 x .010 EVE RAIL 2 x 2 X'[/a" ANGLE CLIP, CUT AT A 45' (+/-) ANGLE AND ATTACHED TO THE 2 x 3 x .010 EVE RAIL WITH ONE (U 1/4' DIA, THRU-BOLT, WITH FENDER WASHER (SEE DESIGN NOTE ABOVE 2 x 3 x .010 SCREEN ROOF PURLIN 5501 NOTE: ALL DIAGONAL BRACING SHALL BE ATTACHED VIA THE 2 x 2 x I/a" ANGLE CLIPS, AS SHOWN, AND SHALL HAVE EACH END ATTACHED TO EITHER THE SCREEN ROOF BEAM OR TO THE EVE FAIL, NO DIAGONAL BRACING SHALL BE AT-T,4CNED TTO_-ANY' OF THE_ROOF PURLINS 2 x 3 x .010 SCREEN ROOF PURLIN 2 x 5M5 SCREEN ROOF BEAM (TYP) SPLICE JOINT r f---- 2 x 2 x I/V ANGLE CLIP, CUT AT A 4$° (+/-) ANGLE AND ATTACHED TO THE SCREEN ROOF BEAM WITH ONE (1) 1/4' DIA. THRU-BOLT, WITH 0 FENDER WASHER (SEE DESIGN NOTE ABOVE 2 x 2 x 0B3 DIAGONAL ROOF BRACE, CUT AT 45' ANGLE l+/-) AT EACH END AND ATTACHED TO EACH ANGLE CLIP WITH A 1/4' DIA. THRU-BOLT, AS SHOWN TYPICAL ANGLE ARTICULATION TO CREATE UPWARD ANGLE DIA OPAL ROOF BRACING [DETAIL OO JH~6- 6wO O caa Lu aI.- U ;lOven LJLJ ®W� �FR.1SL2 o. 00 LuZILLL PLLu C* CL co 0:c co Q �CIREEN ROOF ENCI-06URE e TO - H05T STRUCTURE ATTACHMENT DETAIL f. FASGIA REINFORCEMENT 9E51GN NOTE: DESIGN NOTE: THE 3-INCH LEG OF THE ANGLE SHALL BE --PLACED AGAINST THE I x 2-THIS AI=LOW5 A -MIN. -EDGE — DISTANCE FOR THE FASTENERS (FROM THE EDGE OF THE ANGLE) OF ONE -INCH, AND MAINTAINS A SIX-INCH MIN. CENTER -TO -CENTER DISTANCE FOR THE MAX. SIZED CONCRETE ANCHORS (3/6" x 31i2') CAP (TYP) 1405T C.B.S. WALL (TYP) TYP SCREEN ROOF BEAM I x 2 2°x3'x.125'ANGLE W/(4)012 TEKS, TYP. EACH SIDE OF BEAM ALL FASCIA IE�OARDS ON ANY EXISTING HOST STRUCTURE THAT WILL HAVE ANY PART OF THE PROPOSED SCREEN IENCLOSURE ATTACHED TO IT SHALL BE REINFORCED —BY -PLACING -ONE (-I-)-1/4' x 4' LAG SCREW INTO THE END OF EVERY TRUSS TAIL (WHERE THE PROPOSED SCREEN ENCLOSURE 15 BEING INSTALLED). THESE TRUSS TAILS MUST RE PILOT DRILLED WITH A 5/32" DRILL BIT TO PREVENT SPLITTING THE END OF THE TRUSS TAILS. IT SHALL BE THE REP50N5IBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT TH15 STEP 15 COMPLETED, A5 SPECIFIED, PRIOR TO ANY INSTALLATION TAKING PLACE. FASTENER SHALL BE 1/4' x 3 1/2' RED -HEAD ITW TAPCON FOR ALL 2' x 6' BEAMS AND SMALLER. FASTENERS SHALL BE 3/8' DIA. FOR 2' x 1' BEAMS AND LARGER (SEE DESIGN NOTE ABOVE REGARDING 3/6 FASTENER SPACING) WALL ATTACHMENT F,45CIA REINFORCEMENT 5FECIFIGATION5 1/4' x 4' LACE 6CREW, TO BE INSTALLED INTO THE END OF EVERY TRUSS TAIL WHERE A SCREEN ENCLOSURE WILL BE. ATTACHED. THE TRUSS TAIL SHALL BE f ILOT- DRILLED WITH A 5/32' DRILL BIT (TO PREVENT SPLITTING THE END OF THE TRUSS TAIL) 10-INCH LONG 025 THICK) EXTRUDED SEE 'SNAP /LAP CONNECTION', 'z' GUTTER INSERT, TYP CENTERED ON EACH ROOF BEAM, WITH FOUR (4) 010 NOTE ON SHEET I FOR SPEC.'S TEKS THRU TOP LIP OF GUTTER �Q 2 x 3 x .125 ANGLE CLIP (CUT 2' LONG) W/ 3-INCH 1/4' x 21/4' LAGS, FOUR (4) LEG AGAINST I x 2. CLIP IN EACH 10-INCH INSERT ° SHALL HAVE FOUR (4) 012 AND AT 24' O.C. (MAX. N TEKS INTO SIDE OF ROOF SPACING) IN THE REST 0 BEAM AND TWO (2) 014 x OF THE GUTTER (PILOT - 2' TEKS (PER ANGLE CLIP) DRILL FASCIA W/ 5/32" h THRU GUTTER AND INTO 7' BIT TO AVOID SPLITTING) ° GUTTER INSERT (TYP. ONE N ANGLE CLIP ON EACH 51PE n OF EACH BEAM) '--TYP. 2 x SCREEN ROOF �vI BEAM (MAY BE FLAT 5' STRUCTURAL I x 2 SCREEN 0R SLOPED) GUTTER (CONT) FRAME (TYP) FLAN VIEW TRUSS TAIL (TYP) u-tlnmlNl, Z�. CAP (TYP) 2 x FASCIA BOARD (TYP) NOTE: FASCIA ATTACHMENT REQUIRES A 2 x FASCIA BOARD (MINIMUM). A 'I x' FASCIA 15 ONLY ADEQUATE FOR THIS INSTALLATION WHEN THERE IS A 2 x SUB - FASCIA BEHIND IT. IN THIS CASE, THE LAGS MUST PENETRATE THE SUB -FASCIA 1112' (MIN. EMBEDMENT). IT SHALL BE THE RESPONSIBILITY OF THE SCREEN CONTRACTOR TO VERIFY THE PRESENCE OF THIS 5U5-FA5CI A. 10-INCH LONG 025 THICK) EXTRUDED - 'Z' GUTTER INSERT, TYP CENTERED ON EACH ROOF BEAM, WITH FOUR (4)110 TEKS THRU TOP LIP OF GUTTER 2 x HOUSE FASCIA (SEE FASCIA NOTE ABOVE) 114' x 21/4' LAGS, FOUR (4) ---�� IN EACH 10-INCH INSERT AND24" O.G. )MAX. SPA / SPACININ G) IN THE REST OF THE GUTTER (PILOT DRILL FASCIA W/ 5/32' BIT TO AVOID 5PLITTING) I x 2 x 00 3 ANGLE SPACER - (FOR ANGLED FASCIA BD. ATTACHMENT), ATTACHED W/ TWO (2) ROWS OF 010 TEKS (STAGGERED), EACH ROW AT IS' O.G. (MAX. SPACING) STRUCTURAL GUTTER CONNECTION DETAIL -- TYP SCREEN ROOF BEAM I x 2 uj mmi 2' x 2' x .125' ANGLE W/ (4) 012 TEKS, TYP, EACH SIDE OF BEAM 1/4' x 2 1/2' LAG 6CR EW TYP. I EACH 51DE OF BEAM (2' x 6' SEAMS AND SMALLER) 3/8' x 2 1/2' LAG SCREW (2' x l' BEAMS AND LARGER) FASCIA ATTACHMENT SEE "SNAP / LAP CONNECTION' NOTE ON SHEET I FOR 5PEC.'5 TYP. 2 x SCREEN ROOF BEAM (MAY BE FLAT OR SLOPED) 0 0 2 x 3 x .125 ANGLE CLIP 0 0 (CUT 2' LONG) W/ 3-INCH LEG AGAINST I x 2. CLIP 0 SHALL HAVE FOUR (4) 012 0 TEK5 INTO SIDE OF ROOF BEAM AND TWO (2) 114 x U-CHANNEL 2' TEK5 (PER ANGLE CLIP) CAP (TYP) THRU GUTTER AND INTO 'Z' I x 2 SCREEN GUTTE INSERT (TYP. ONE FRAME (TYP) AN G CLIP ON EACH SIDE 5' STRUCTURAL GUTTER (CONT.) 5ECTION VIEW OF ACH BEAM) 14 C Hi j �L30 ~ u-�j < CD CL m 2 x � x.3/16' ANGLE, WITH FOUR (4) 112 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) SIDE WALL--J -'I-- / - --%- - I x 2 05 BOTTOM FRAME I x 3 05 SIDE -WALL UPRIGHT 2 x 3 x.010 EVE RAIL, TYP. (CONTINUOUS) J L N PLAN VIEW I x 2 05 TOP FRAME ' I x 3 015 SIDE -WALL CORNER - UPRIGHT 010 x 2' SM5 SCREW, WITH 5/8' - DIA. WASHER (SEE GENERAL NOTE 03, SHEET 02) TO 5E 18- INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 2 x 3/16' ANGLE, WITH FOUR (4)12 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) I x 2 OB BOTTOM FRAME ELEVATION VIEW FRONT WALL I x 2 OB BOTTOM FRAME 2 3/4', MIN. EDGE DISTANCE 3 x ,010 FRONT WALL 2NER UPRIGHT - 010 x 2' SMS SCREW, WITH 5/8' DIA, WASHER (SEE GENERAL NOTE 03, SHEET 02) TO BE IS - INCHES, CENTER- TO -CENTER MAX. SPACING MANSARD SCREEN ROOF 5EAM(5EYOND) 2 x 5 x '/a' ANGLE (2-INCHE5 LONG) WITH (2) 114 TEKS INTO TOP OF 2 x 3 EVE RAIL AND (2) 014 TEK5 INTO THE FRONT OF THE 3 x 3 H FRONT WALL CORNER UPRIGHT 3 x 3 x ,010 FRONT WALL CORNER UPRIGHT 2 g/4 MIN. )GE DIST CE- 0 0 G ►a CORNER UPRIGHT [DETAIL NOTE; THIS ATTACHMENT I x 2 O.B. SCREEN FRAM, DETAIL ALSO APPLIES TO TYP. BETWEEN UPRIGHTS A 2 x 2 SCREEN FRAME, OR A6 UPRIGHTS A6AIN6T W/ THE FASTENER BEING A WALL OR COLUMN 4' IN LENGTH, TO 1/4' DIA, x 31/4' TAPCON MAINTAIN A 2' MIN, TO 6E PLACED AT NO MORE EMBED. THAN 18' O.C. (RE: GEN. NOTE #3) MIN. EMBEDMENT FOR CONC. / C.B.S. / MASONRY ALL TAPCONS SHALL — SURFACE - BE 2' INTO CONCRETE. NOTE: ALL FASTENERS SPECIFIED IN 'COLUM-TO-FOUNDATION' DETAILS PERTAIN ONLY TO THE FASTENERS TO BE PLACED ON EITHER SIDE OF COLUMNS, THIS DETAIL IS FOR ALL INTERMEDIATE FASTENERS FOR I x 2 SCREEN FRAME TO EITHER CONC. DECK OR C.B.S. MASONRY WALL.; . NO. OF 014 TEKS BE 4M 31zE —__(FER 50E) 2 x 5 - 2 x b (2)#14TEK5 2 x I - 2 x a (4)#14TEK5 2 x S (5) 014 TEKS 2 x 10 (9)) 014 TEKS 2 x SM5 SCREEN ROOF BEAM 2 x 3 x .070 ROOF PURLIN 21/e' x I1/2, U-CHANNEL CLIP ATTACHED TO THE EVE RAIL WITH SIX (6) 012 TEKS, AND (3) 2 x 3 x .010 ROOF PURLIN 012 TEKS INTO EACH SIDE OF 2 x 3 x .010 EVE RAIL, o THE 2 x 3 ROOF PURLIN (TO TYP. (CONTINUOUS) o BE ATTACHED ON THE TOP a END TO THE SCREEN ROOF — —1 2 x 5 x/e' ANGLE (2-INCHES BEAM IN THE SAME MANNER 2 x 5 x I/e' ANGLE (2-INCHES 0 0 1 LONG) WITH (2) 014 TEK5 INTO LONG) WITH (2) #14 TEKS INTO o o TOP OF 2 x 3 EVE RAIL AND TOP OF 2 x SM5 SEAM AND I (2) 014 TEKS INTO THE FRONT -2 x 4 x /a' ANGLE (2-INCHES (2) 014 TEKS INTO THE FRONT o oV OF THE 2 x SMB SIDE WALL LONG) WITH (2) 114 TEK5 INTO OF THE 2 x SM5 FRONT WALL UPRIGHT BOTTOM OF THE 2 x 3 PURLIN UPRIGHT AND.(2) 014 TEKS INTO THE 1 x 2 05 TOP FRAME BACK OF THE 2 x SMB SIDE I x 2 06 TOP FRAME WALL UPRIGHT 010 x 2' 6116 SCREW, WITH 5/6' DIA. WASHER (SEE GENERAL NOTE 05, SHEET a2) TO BE 18= INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 5 SM5 UPRIGHT (MINIMUM SIZE FOR ANY UPRIGHT ON A SCREEN ROOF ENCLOSURE) 23/4' MIN. ED DISTANCE SEE 'MINIMUM FOOTER TABLES' ON SHEET 01 010 x 2' SM6 SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL 2 x 3 x .010 CHAIR RAIL (TYP) NOTE 03, SHEET "2) TO BE IS - INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 2 x 3/16' ANGLE, WITH FOUR 2 x 5 SM5 UPRIGHT (MINIMUM (4) *12 TEK5 INTO THE UPRIGHT SIZE FOR ANY UPRIGHT ON A AND ONE ll) 3/8' RED -HEAD SCREEN ROOF ENCLOSURE) 'TRU-BOLT' WEDGE ANCHOR (MIN, OF 4-INCH EMBEDMENT INTO THE CONCRETE) Ix2OBE SIDE WALL UPRIGHT DETAIL 23/4' MIN. EDGE DISTANCE I x 2 OB BOTTOM FRAME — SEE 'MINIMUM FOOTER --� TABLES' ON SHEET 01 9/ ° 3' MIN. MIN. SCREEN ROOF SEAM SHALL OVERLAP ON THE OUTER SIDE OF BOTH -SIDES OT THE UPRIGHT (TYP. EACH BEAM -TO -UPRIGHT CONNECTION) SEE TABLE A50VE FOR NUMBER OF 014 TEKS, AS SPECIFIED 5ASED ON SEAM SIZE 2 x 3 x .010 CHAIR RAIL (TYP) 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE (1) 3/V REP -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. of 4-INCH EMBEDMENT INTO THE CONCRETE) FRONT WALL UPRIGHT [DETAIL V3 u o� m 0o®w Z � t= we goz�R LL r Z3 0 cazwe < W (LLL LL ® Lu w 0 C. ." � w�