HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY:'= ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED t - - St. Lucie County Building and Zoning �� ® 2300 Virginia Avenue AIVNED Ft. Pierce, FL 34982-5652 131y 772-462-1553 St Lucie C®u,, `J' APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: q075 --Sftfl 0 ��C,{ e 2. S/D NAME. 7 Akli r1a SITE PLAN NAME: 3. PROPERTY TAX ID #: 9 — O i 4. LEGAL DESCRIPTION (attach extra sheets if necessary): 5. PLAT 6. PAGE 7. BLOCK 8. LOT (Q BOOK NO. NO. NO. 9. PARCEL SIZE: ACRES/SQ FT. � I a-76)LOT DIMENSIONS � �,7 / .X 1w 10. SETBACKS (ACTUAL) FRONT BACK: 0 RIGHT SID�,5 LEFT SIDE; 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) N=New SG = Slab on Grade SQUARE FEET OF TYPE OF CONSTRUCTION A= Addition SR = Raised Slab DIMENSIONS CONSTRUCTION R = Rebuild WD = Wood Deck SCREEN ROOM NEW ❑ EXISTING X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ZEW ❑ EXISTING X POOL ENCLOSURE R NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet ❑ ROOF SYSTEM OVER ❑ NEW ❑ EXISTING X EXISTING ACCESSARY STRUCTURE ❑ OTHER: ❑ NEW ❑ EXISTING X TOTAL SQUARE FEET OF CONSTRUCTION 12. VALUE OF CONSTRUCTION: $ "l 100 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 8116106 ding OWNER INFORMATION, �� w tl M I .A NAME: � 1l _ ADDRESS: D r-f 1 I n CITYT-bT 2 L (del(A _0 STATE: ZIP PHONE (DAYTIME): ( L� LO (Q ( GD 5 email: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: '1 FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: aXbWw M r) ST. LUCIE COUNTY CERT #: J� BUSINESS NAME: QUALIFIER'S NAME: I I%—rn 1m ht o y ADDR/S, ESS: 9 � 1M�Rdi-) l (_—y� L G.�t CITY: K%a,,/9 ,� ram na d - ) STATE: ZIP PHONE -(DAYTIME): ') 7`� " % FAX Nfttl el NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) ; S `F fir_} NET -.Rtir4�.0�c 4 i=.v _ .i.. _-. Y�]j{uii�: .�r 1 :.. _. .sv:�Yv;4:-v,__.. -_ }. _ _z _r.. � Jh_ ', - � ^_ "v .?�Gia�-_iY3,-i}-,arrii_. v_T-�- -:s_ _ if- ..x__-_v :.-:.Y^-n'�:v.:. is}ri•}._y ^"x.Yc.:ss�iii.�•} � �,�?s"�:i. -=:r:n. �: _3 ?a- v-�'+ _ _ -{+nn'Frvv_- li-.'+-•-"- v_-_fg�, v^- cz_s _ iv$�i__ '-*h,-i-r'.� ^::-?i—z"v�rix:Fi- 'K1'_ f ' vvA4Y. _ _ __.iT, .' �__ _ '4� :_�i?,'s}G.._f`_�},f._" =:i-xr}:c_r, :=, � �,'�� ..:� _ -r�.P s �`.__ k�.____._-.._=_,�::-::x_rrr._ �"�.,.._�_'_�__-_..,_�,Y_.�:x _-�"'�_�z'f-.�� r+:_�-•:_=:=v�_�>_�:.:� t: x.x__ _''''_.-°�` "-�,__ .f?,trr�=-�_.�.,,'� ,�-:a:-:�,.�_==izr:=:` .............� _�._ _ _ __ 't';. SECTION 2 TOWNSHIP v / `J l Sl RANGE 2Q �J / MAP NO.�131� A % Additional Yes ZONING +1 lh�J LAND USE C' LOT CVG % Permits no J REPORT CODE �`] ] BIMS FEE $ MISC FEES $ TOTAL FEES �� � REVIEWS ZONING ZONING PLANS MISC. VEGETATION REVIEWED BY EXAMING DATE 4I COMPLETE INITIALS PLAN REV tj�W SPECIFICATION CH��;KLIST 7 PLEASE PROVIDE ONE OF THE FOLLOWING: ❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with either AAF Guidelines or another approved Engineer's Manual. ❑ 2 Design Checklists from an Engineer's Manual (if applicable), completely filled out with original, and approved signatures affixed thereon. ❑ I choose to use the approved County Aluminum Plans and Specifications for this project and will not need to comply with (I) below. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans and specifications must follow the checklist if using an Engineer's Manual and checklists may apply from multiple chapters. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using an Engineer's Manual, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. M• All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must -be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, section 2002. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self -catching gates with picket spacing. (I]) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" component highlighted and witli fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC 1202.1) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite)- OVER EXISTING ADJACENT. STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) (b) (c) A 4`h wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. That the complete guide to H.U.D. specifications be strictly adhered to. A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. I the Contractor / Owner Builder hereby certifies that the components being used, fastener type, and fastening pattern meet all the proper design pressures for the structure located in the designated wind zones set by the county, along with applicable tables 1606.2A, 1606.211, 1606.2C, and 1606.21) of chapter 20 of the Florida Building Code and the Engineering as submitted, and takes full responsibility for complying with the submitted calculations of the design pressures of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requiremen g ofAe Engineer of. Record and is in adequ a dition to withstand the uplift and weight of the aluminum structure an said tructure will not exceed �he footprint o�the ructure that was inexistence prior to removal by the stores. SIGNATURE STATE OF COUNTY( 11glore g instrument was acknowl ed before e�da, ersonall lmown to me or who has produced STATE OF COUNTY( The foregoing instrument w ackno d efore me this y of by ,who s persona wn to me or who has produce ieisersa !-zm°ofi I Johnsoll ie (SEAL) a?PY `r Cu m.; son#DD452009 (s ;)" ^ khanterra J. July14, _ :Cotes Johnson %oFP-'`" R .otiNoTARY.com _ _. - Sion #DDT 50903 IMPORTANIR'i'dO`Y'ICE�w ` „ s p`ULY 14, 2009 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. iILYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. Code Compliance Division 2300 Virginia Avenue Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stlucieco.gov/ce Issued: 04/16/2008 Job Location: 9075 Short Chip Cir Permit Type: Building (Miscellaneous) Job Description: BUILDING PERMIT Conf #: 812 Permit #: SLC- 0804-0032 City: PORT ST LUCIE INSTALLATION OF POOL ENCLOSURE FOR SINGLE FAMILY RESIDENCE Page 1 S/D Lot: 24 Block: D Parcel: 3334-501-0162-000/6 Contractor TRIMBLE HOWARD JAMES SCREEN BUILDERS INC (561) 793-6029 8451 MCALLISTER WAY WEST PALM BEACH, FL 33411 Property Owner PAUL SPICONARDI (772) 466-1923 9075 SHORT CHIP CIRLCE PORT ST LUCIE, FL 34986 Property Owner BARBARA SPICONARDI (772) 466-1923 9075 SHORT CHIP CIRCLE PORT ST LUCIE, FL 34986 Setbacks Left: 23.50 Right: 17.00 Front: Rear: 0.00 Zoning: pud Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: 275F Flood Zone: X Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from othgr governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Code Compliance Division 2300 Virginia Avenue Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 16 April 2008 Job Address: 9075 Short Chip Cir Received By: dimonb Paid With: CK Paid By: SCREEN BUILDERS INC Building Receipt Receipt#: 0000062159 'ermitNumber: SLC- 0804-0032 Amount: $80.00 �redit Card Number: Check Number: 6389 Sign: EDWIN M. FRY, Jr., CLrPv OF THE CIRCUIT COURT - SAINT LUCIE C'^T-?WTY FILE # 3187621 OR BOy 955 PAGE 2210, Recorded 04/01/2008• 'D9:47 AM n• c i J NOTICE OF C_ OnIMENrEMENT TO BE COMPLETED WHEN CONSTRUCTION VALUE EXCEEDS i1,S00. PO PERMIT 9: _ SQ D. ��- TAX FOLIO H:f.7.r1�.I. Q (p STATE OF FLORIDA COUNTY OF 5T LuG1E THE UNDERSIGNED HEREBY GIVES NOTICE THAT IMPROVEMENT WILL BE MADE TO CERTAIN REAL PROPERTY, AND IN ACCORDANCE WITH CHAPTER 713, FLORIDA STATUTES, THE FOLLOWING INFORMATION IS PROVIDED IN THIS NOTICE OF COMMENCEMENT. LEGA1, DESCRIPTION OF PROPE TY (A D STREET ADDRESS IF AVAILABLE ts�,9 Q ��a �;��cae a Cy.Ad� Cr,c(e GENERAL DESCRIPTION OF IMPROVEMENT:0'aA Cf C eer, 'OWNER NAME: A DDRE PHONE NUMBER: INTEREST IN PROPERTY: CI1rrQ NAME AND ADDRESS OF FEE SIMPLETITLE HOLDER (IF OTHER THAN OWNER): SCREEN BUILDERS, INC. CONTRACTOR: R4rl McAl I ISTFR WW S�6: �j—lal7 ADDREss: _ WEST PALM BEACH, F6 83411 PHONE NUMBER: FAX NUMBER: SURETY COMPANY (IF ANY): ADDRESS: PHONE NUMBER FAX NUMBER: BOND AMOUNT: LENDER/MORTGAGE COMPANY: ADDRESS: PHONE NUMBER: FAX NUMBER: PERSONS WITHIN THE STATE OF FLORIDA DESIGNATED BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAY BE SERVED AS PROVIDED BY SECTION 713.13 (1) (a) 7., FLORIDA STATUTES: NAME: ADDRESS: y PHONE NUMBER: FAX NUMBER: IN ADDITION TO HIMSELF OR HERSELF, OWNER DESIGNATES OF TO RECEIVE A COPY OF THE LIENOR'S NOTICE AS PROVIDED IN SECTION 713.13(IxB), FLORIDA STATUES. • PHONENUMBER: FAXNUMBPR: EXPIRATION DATE OF NOTICE OF COMMENCEMENT: (THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED). WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST ' INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMNMN�1N_C M OR RECORDING YOUR NOTICE OF COMMENCEMENT. ,ae 1 SIGNATORY'S TITLE/OFFICE THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _DAY OFF 260y �ti� r .\ BY: lard:. �Cl]u�mLYfi AS FOR iu NAME OF PERSON TYPE OF AUTHORITY NAME OF ARTY ON BEHALF OF PERSONALLY KNOWN OR PRODUCED IDENTIFICATION WHOM INSTRUMENT WAS EXECUTED Lu ry ,., I`ctary Pvblic 5ta13 of Floida TYPE OF IDENTIFICATION PRODUCED `� ;Q Cindi7om ton W (1z g . Commission DD579274 — U- er IV E 1010812010 3wres m C�l N T 9Y GNATURE NOTARYSEAL >- 1— � UNDE PENALTIES OF PERJURY, I DECLARE THAT I HAVE READ THE FOREGOING AND THAT THE FACTS 1N IT AREI•-CD - T E T THE ST OF MY KNOWLEDGE AND BELIEF (SECTION 92.525, FLORIDA STATUTES). i Q C-D GDPLD (S n4fLupy6f Naturnl Person Signing Above) u-- ly- QUO l�C--)0 ly��p� ® CD Lu < _ I— UJ CC V3 to r �- 0 m �Y 9079 SHORT,CHIP CIR i k ROW Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 03 April 2008 Job Address: 9075 Short Chip Cir Received By: GERSTEML Paid With: ck Paid By: screen builders inc Building Receipt Receipt M 0000061911 'ermit Number: SLC- 0804-0032 Amount: $50.00 �redit Card Number: Check Number: 6363 Sign: Na AIVU D/UXUAIRA W 1L UIVAKUI e r Boun d ory Survey Note: All Bearings do Distances Are As Per Plat unless Noted Otherwise. OnA U) d9° t WTter OP.0 perk v P° ed ECG' Lo 3 0 . C°ver (b.I 0.8 q,45 `OD' q,5 P � SYstStem R1 9 S' 24 Reg den e #90Y5 w 23 Covered \ entry F MIN. SETBACK,REQ. g- 5 FRONT D S SIDES i CNR SIDE I y� j REAR P5 D PO 1 ZNG. ILL D' TECH. .P•tr '0. (A3 ABC unit a`�` oqer Block D r j 2' Concrete Valley curb \ cn r S o Point of �1 iReverse Curvature I 1 Right —of —Way Cul--Ds—Sac —: 40' ftl/7t—Ot-Way Edge. of Pavement Radius Point Sh .o r t Ch (Rodfus=55 00) ip Circle ADDRESS: 9075 Short Chip Circle Port St. Lucie, Florida Lot 24, Block D, LAKES AT PGA VILLAGE, according to the Plat thereof, as recorded in Plat - Book 43, Pages 32, 32A through 32F, of the Public Records of St. Lucie County, Florida. CERTIFIED TO: •PAUL SPICONARDI AND BARBARA SPICONARDI; WORLD SAVINGS BANK, FSB, ITS SUCCESSORS AND/OR ASSIGNS; TICOR TITLE INSURANCE COMPANY OF FLORIDA D/B/A CHELSEA TITLE COMPANY -P^I Found 518" Iron Rod (No Cap) "y wL c-r, OIVUK U, LARCJ Al VUA VILLAGt 4: sloa wTIE BY Land Surveyor 10556 South Federal Highway P.O. BOX 690 term BUCe. FLORIDA SAW (772) 398 — 8166 FAX (772) 337 — 7404 CMUMATr Thla to oertlty that ihla. BIE= OF sURnT, of the hereon true contaiMadns a FroMrt7. Btanderda ud, and to. In Ceayter 6 to the boat of m7 Imoaled6e and baker, shown, and meets tha IBM— Teotmled 17-6 FA.C. b the Florida sur-yorn P to 8eotlon 4 Board of land 027. Florida t tots. Mm NOT VAM Ummas FRIUM ra$ AN 1o1608M sURt'arolrs mu_ PBIIB IF. LUiOTlM 1 is URUTptl U*dftm i P.LSIL 03152 1 ollent. FLOOD ZONE: X ' o .O � O Y a_ n o N N I c 10'-6" IL 3'X6'-8" 3X3/202 o DOOR 202 1 N 5LB �'3 5LB rn I m 5LB X N V N LA RO a O N 0 5LB I i Qy F IR • Co a � n ^F 1 X2 � i NeLLL-�------------y 30" 4'-0" DASHED INDICATES ECTIO ST. LUCIE COUN"y 13uILDING �E� N . 1X2 1- X ��1� 2X3XO5 -j X �G 0 1X2 4'-0" 5'-6" w cn 0 x Ln w REAR ELEVATION A iflo--, PLANS 4Ft-4 P'ru IT UST BE KEPT ON JO8 OR QidrPE9;YV1LL �0 DEEXIST. RAISED SLAB 303 .\ oo %' w rn X N O Do I 8LB `Go w X X N N w 8LB 5LB 2X3 M i 5LB . 2X3 303 ST. LUCIE COUNTY DESIGN CERTIFICATION CODE EDITION: FBC 2004 EDITION W/2007 AMENDMENTS OCCUPANCY: SINGLE FAMILY DWELLING — SCREEN ROOM BUILDING DESIGNED AS: OPEN STRUCTURE BUILDING HEIGHT < 60 FEET MEAN ROOF HEIGHT: 13'-0" IMPORTANCE FACTOR: 0.77 BASIC WIND VELOCITY PRESSURES: WIND SPEED: 140 MPH. (3 mcom cusp BASIC WIND VELOCITY PRESSURES: 6 PSF ROOF 21 PSF WALLS ROOF DEAD LOAD (ACTUAL DEAD LOAD USED To REm7 uPuFr REAcmNs): 0 PSF SOIL BEARING CAPACITY: 2500 PSF REVIEWED FOR SHEAR WALL REQUIREMENTS: YES NO IMPACT PROTECTION REQUIRED FOR SCREEN ROOMS ATTACH TO EXIST. 2" FASCIA 44'-0" EXIST. HOUSE EXIST. 16" O.H. 1X2 SUPER GUTTER Do mDO IIll m co I DO I 00 I 00 414 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS o Y REQUIRED BY FIELD INSPECTORS THAT o MAY BE NECESSARY IN ORDER TO O O COMPLY WITH ALL APPLICABLE CODES. < z NOTE: ----- DOOR LOCATION IS OPTIONAL 1 R of CONTRACTOR MAY ADJUST IN O FIELD PER HOMEOWNER REQUEST w(A `n 1X2 m :3 tk= w c (� uj NOTE: v a = x u CONTRACTOR MAY USE ~ N I LARGER MEMBER SIZE c U w o THAN SPECIFIED ON THIS W -T- 2X3XO70 PLAN ON THEIR DISCRETION. 0 0 1X2 M 00 = 18" 8'-0" NOTE: I 9'-6" THIS JOB WAS DESIGNED . CC) co _II C) j BASED ON'6061-T6 0 00 m m REAR ELEVATION B ALUMINUM ALLOY. o\ w z W 10'-6" cn o U (n N 3'X6'-8" 303 3X3/202 00 2X3 2X3 PLAN ic 44 ti"t� �P®NS�A N® c ' DOOR 202 p w o LL- 0 i I to J 5LB 6LB O c/) U Z ~ Z In O -I c� LL W W ��X LL I Lu C) W = W U) \ o O ``� \LB m o co J 0 W �_ IV- '� d' ro Do N Ld Z Ei It-4O • r W Z5LB Z ~ = Q W N U V u) F- H CD O I. 0_ z � ^ O (n ((nn rn a- v0 ``� Gov •1 o O N 0QB 00 06(03 \`T OD 1 X2 Y o m U rn Cq� --------------J�301� w w Z I � 66 4'-0' O N C.)11'-6" N O ❑-. .. mW Lo LL F•r1 = 0 "; 1 I 1X2 1X2 1X2 a � DASHED INDICATES z �� X j SECTION BEYOND \� m m m m m m m ELpGi X .'�5C, F to co 0 � to to 0; m I to 03 CIDI j 2X3X050 �� 2X3XO50 i 2X3XO50 K 1 X2 BRA 1 X2"---_ CE r��.rr»�7--z fiI , -, / / // 13 -2 7/ //// `30" / / / / ///i i i / / / g 21' 6 19' 21. 8 19•//, - Ti13 =2•i i O I /j / / / / / / / / / / �3(]� O FOUNDATION INFORMATION SHOWN ON 1NI5 PUN IS 845m ON DATA � THE REOLwREDTOTO R�STT ALL SUPERIIMMPOSm FOUNDATIONS // / // 8• 1B /iiiiiii % // i i AND DEAD LOADS FROM THE PROPOSED STRUCTURE 1L11 LLL✓/J 1111 tt LLLL J L a. —0" 7'-4" L 7'-4" L 7'-4" 7'-4" 7'-4" 7'-4" 1 L 8'-0"� oo -o FRONT ELEVATION EXIST. CONC. SLAB WITH / / CONT. 8"X8" MIN. FTG. G N Who aC '' X o F `U'j ; CL � � � 1Ir co O CD•-z 3 p LL C3 Z �' Z O ZO ' c� c0o o IL r ^ r Z w a cn O o Lo Q m N W Z (n = E--1 v a �- o V' 4 - #10 SMS. INTO SCREW SLOTS EA. PURLIN 3' 2X3X050 2X3X050 OR 2X4XO50 OR 2X4XO50 1 1/2' X 2 1/8' X .062' RECEIVING CHANNEL W/ 6 - #10 SMS. INTO BEAM & 3 - #10 SMS. INTO BOTH SIDES OF 2X3 3' {050 2X3XO50 2X4XO50 OR 2X4X050 LAP BM: ALT, PURLIN C❑NNECTI❑N 2' LG. SCREWS REQUIRED (U ' LONG X 1/8' ANGLE EA. SIDE OF COL, 3'X3'X.072' W/ 4-#6 TO COL. & 1 - \ 3/8' X 4' LG, TAPCON \ O TO CONC. @ EA. CLIP \ 2' LG, SCREWS REQUIRED \ \ blXp O 1X2 O 2' X 2' X 1/8' ' ANGLE W/3 - #1 (2) #10TXLCi.1/4' X 2 1/4' 1 EA. FABRICATION SCREWS TAPCONS @ 18' O/C RE it TERNATE CORNER C ❑LU 2' X 4FASCIAw '' LAP BEAM FLAT ANGLE(2)- OR SLOPED #4 OREAM / / 3/8' X 2 1/2' LONG LAG ANCHOR THRU CLIP & 1X2 INTO EXT. FASCIA AND @ C.C. ELSEWHERE ADDITIONAL #5 REQD. FOR MIN. 2'8LB BEAMS OR LARGER W/ (3) - #6 TO BEAM & (1) - #7 TO FASCIA. BEAM C❑NNECTI❑N AT FASCIA ■ ALL EXISTING FASCIA TO BE A MIN. OF 2' THICK AND MUST BE SECURED TO EACH TRUSS OR RAFTER END W/ A MINIMUM OF ONE 1/4',X 3 1/2' LAG SCREW PER TRUSS OR RAFTER END. 2' X 2' X 1/8' CLIP LAP BEAM FLAT ANGLE EA. SIDE W/ (2)- OR SLOPED #4 OR (4) -#6 TO BEAM IX2 EXIST. TIE BEAM OR / CONC. / 1/4' X 2 BLOCK ANCHOR TF..:.:...;::8.:<k.?' INTO EXT. W/ (3) & (1) - 2LONG 4' C.C. SUPER Ir PICKET EA. LAG 1X3 IS— S GUTTER I •. V'XI' 2 EA. BM.) OPTIONAL 2' X 2' X .125'— CLIP ANGLE ON EACH SIDE OF COL. 3 - #14 TEK SCREW/ HEX HEAD EACH CLIP TO COLUMN (1) 3/8' THRU b.¢ .............7 WASHER/NUT THRU 202 LAP BEAM FLAT OR SLOPED TEK EA. SIDE EXIST. D.H. & 2' FASCIA INTERIOR FASTENING 4 - #10 X 1 1/2' SMS. INTO SCREW SLOTS EA. SIDE �2' OR 2 ❑R2X43 OR X4 COL. ellC❑NNECT THICKNESS PER SCHEDULE 'K' BRACE INSTALLED AT COL. OUTSIDE FACET USE 5'X8'X.064' MIN. PLATE W/ 12 - #2 'S INSIDE, USE .064' MIN. ANGLES 1'X3'X3 1/2' LG. W/ 10 - #2'S (ONE ANGLE ABOVE & ONE ANGLE BELOW CHAIR RAIL) 4 NOTE, PROVIDE MIN. 3/4' BETWEEN FASTENERS & MIN. 1/2' EDGE DISTANCE BOLTS @ 2 - #4 OR 'XI' PICKET EA. GK#TER BRACE TO 3 - #L EA. @ EA. LAG FASCIA & (1) 1/4' X 3' CLIP TO COL. 3/8' X 9' LAG BOLT THRU LAG @ 24' C.C. 2' X 2' X 1/a, EA. CLIP & 202 AND GUTTER ELSEWHERE AT GUTTER ANGLE EA. SIDE <24' C.C. ELSEWHERE) SUPER GUTTER (TRANSOME) KNEE WALL/FASCIA CONNECTION ATTACH U-BRACKET TO 1/2 OF BEAM W/ 1/4' X 3/4' BOLT & NUT. ALSO 2' SQ. WASHER INSIDE 1/2 BEAM. 1/4' THRU BOLTS UT LOCKS FOR TELESC&OPE BRACE �1 3/4' X 1 3/4' X .090 TUBE IPLA' 1/4' X 2' X .125' U- ':3; X 2' X .090' TUBES I I r_(TOP VIEW) .062' SQ. WASHER BOLTED ON 3' LEG & #12 TEK ON NOTE 1' LEG USE 1/4' X 3/4' THRU-BOLT AT ALL NON -SPLICE AREAS W/ ATTACH U-BRACKET TO 2' X 2' X .125' ALUM. OUTER SCREEN WALL W/ SQUARE WASHER & NUT 1/4' X 2 1/2' THRU BOLT ALT. ROOF BRACING (TELESC❑PI 1/4' LAG X 3' LONG INT. OPTIONAL 1X3 W/2 #2 :A EA. TRUSS @ 24' C.C. MAX, TO BM. (INTERNAL) & #2 X 2' LONG @ 24' C.0 BETWEEN BEAMS EXIST. #5 CLIP OF RUSS & W/:'.:» FRp CLIP?: nscTn a � BEAM ..:...::.�f. 1X3 '' 1X3 ALUM. 1/2' 1(l?;1 DNG9:'1 #1 - 2' LONG @ 24 ,C. FROM BEAM " X 9' LONG LAG EA 1X3 TO SUPER GUTTER _IP THRU 2' FASCIA w BETWEEN BEAMS NOTCHED 4'X4'XI/8'� !>; l SUPER ADDITIFI "°- ? `' :: W :#: 2 - #4 TO BEAM OR 4 - ALUM. TUBE SPACER ?i'::•PACE 2'X2'X2'X.125' TH Eq, gM GUTTER LAG o #6 EA. CLIP TO BM. `r'>%;:s.'z�:s:;•:::: AL, ANGLE CLIP 1'Xl' PICKET(2 EA. BM) (EA. SIDE OF BM.) OPTIONAL CUT GUTTER C❑NNECTI❑N DETAIL (MANSARD & FLAT ROOFS) FORE712G TTERSG J AL . GUTT CREEN FABRIC DETAIL SHEET: PER F,B,C. 2004 EDITION W/2007 AMEND X TS EA." §Eii<.jsir'. %#':':ffR SCHED. BELOW RFf3,n it f1F @id TFK SCREWS BEAM EA. BEAM/ EA. SIDE TOTAL BOTH SIDES 4LB-6L 6 24 7LB 8 32 8LB 9 36 9LB 10 40 10LB 11 44 NOTE - PURLINS NOTE, "f MAY BE FLAT OR PROVIDE MIN. 1' SEP, BETWEEN FASTENERS. MIN. SLOPED 1' EDGE DISTANCE BETWEEN FASTENERS & GUSSET PLATE 2' MIN. FASCIA 2X3X0.050 5LB OR 2X3X0,070 > (SLOPING PURLIN) 3X3X0,070 CONTINUOUS \ \ / 1X3 1X3 NOTCH COL. F. 1'XO,090'X8' LG, STRAP W/ (7)- Nplty;1?j FASCIA MAY BE BY LAGGING NEW 1' 2' X 2' X 1/8' ANGLE #10 TEK SCREWS st'0 OLD W/2 - 1/4' X3 f.d'*'LAGS/TRUSS OR RAFTER, EA. SIDE W/ 2 -#7 TO _ 2 - 3/8' THRU 2•' -FASCIA BEHIND 1' FASCIA & (6) - #6 2X3X0.050 FLAT TO PURLIN BOLTS OR SUB FASCIA IS ALSO ACCEPTABLE 4 - 6�,EA, SIDE TS :TO 'LAG 3 r6' LONG 'Z' GUTTER BRACE @ EA. ALUM. BM. lrOPTIONAL 2'X2'X.125' X 3' LG. CLIP 1X3 AM ANGLE ONE EA. SIDE OF BE BEAM ? - #4 OR 4 - #6 EA. NED FASCIA ! I/ -- 2PRI NAL CUT OFF ALUM. SUPER I I GUTTER L— 4 - (#1) PER CLIP THRU 1 X 3 GUTTER @ GUTTER BRACE , 140 MPH I SCREEN BUILDERS 2' X 2' X 1/8' Y ANGLE W/3 - #1 S, I' 't EA . FACE FF i rn1 -rn COLUMN DETAIL DATE, 03/13/08 SCALE, N.T.S. SHEET, .T. TARNOWSKI, P vl irn IDAI rIJf'IM=R - FIA - 1 11 HOST STRUCTURE 2'X2'X.090' r �#5 -ANCHOR TO EAVE MEMBER W/ <D- 3/8' THRU BOLT -BRACING MAY BE INSTALLED ON TOP OR ON THE SIDES OF BEAMS AND EAVE MEMBERS. -ANCHOR TO LAP BEAMS W/ (1)- 3/8' THRU BOLT OR (2)- #14 TEK SCREWS ROOF BRACING (TYPICAL PLAN) ■REFER TO SITE SPECIFIC PLAN FOR ADDITIONAL BRACING REQUIRMENTS SITE SPECIFIC ENGINEERING SUPERCEDES THIS GENERAL GUIDE FASTENING SCHEDULE #1 - #14 TEK SCREW/HEX HEAD 42 - #10 S.M.S./HEX HEAD # 3 — N ANCHOR / TAP(❑ /��- 212 1 .. .X �a� #�4 4: 3�' �❑L/ S/'WASHE R/NUT AII - CLIP ANGLE,.125 j1MA #6 - #12 _; EAD #7 1/4 '�X 2 °1/2 LAG #9 - / ' S.M.S./Hd HD. #10 X 1 12 1` U► �- D (U v W g ffi m M � 0 J 0 � U n (U — a-+ x tL a u In v1 in j z �m r�6 '.6 w F Q 59 F. Z z � J O¢ W W n d 2 L, «^ ~~ O_��� CHAIR RAIL SCHEDULE ALL.-CALCULATI❑NS BASED ON THE F❑LL❑WING CRITERIA: 1. FOR SCREENING WITH ❑PENINGS > 607 SPANS ARE BASED ON LOADS FROM FBC TABLE 2002.4 LOADS ARE APPLIED SIMULTANE❑USLY TO WALL & ROOF 2. 6 PSF ROOF + 21 PSF WALL C❑MBINED LOAD & 300# N❑N-C❑MBINED LOAD -3. EXPOSURE B, IMP❑RTANCE FACTOR = 0,77 4. DESIGN MEETS L/60 DEFLECTI❑N REQUIREMENTS SCREEN BEAM SCHEDULES WITH MANSARD ROOF MAXIMUM SPAN - RAIL 4' 1 5' 1 6' 1 7' 1 8'1 9' 2X3X 501 8.3 1 7.7 17.2 6,8 6.5 6.2 2X3XO70 9.2 8.5 8.0 7,6 7.3 7I) LOAD FACTOR = 1/2 THE DISTANCE TO CHAIR RAIL OR BELOW + 1/2 THE DISTANCE TO CHAIR RAIL OR EAVE EAVE MEMBER SCHEDULE MAXIMUM SPAN EAVE 1 4' S' 1 6' 1 7' . . 3X3XO72 11.0 1 10.1 1 9.4 1 8,g;'ils: LOAD FACTOR = 1/2 THE DISIANGE RAIL BELOW + 1/2 OF THE MANSAF W/ 8' COLUMN HEIGHT W/ 10' COLUMN HEIGHT W/ 12' COLUMN MAXIMUM BEAM SPAN MAXIMUM BEAM SPAN MAXIMUM BEAM:: BEAM 4' 6 6' 7' 8' BEAM 4' 5' 6' 7' 8' BEAM 4' 5' OLUMN HEIGHT IUM BEAM SPAN COLUMN 5' 6' 7' 8' >SPACING 0 4LB 11.3 6.1 - - 4LB 7.5 - - - - 4LB J?'?.. G✓ Q 5LB 18.6 14.8 11.5 7.8 5LB 16.4 12.1 7.0 5LB 14.1 &'r �:.:.. '- 3i:...'�..... z'i: #� 7.0 x � 6LB 23.5 19.5 16.3 13.6 10.6 6LB 21.6 17.4 13.8 9.8 4.7 LB 19.7 'i;`;�.;�::::;,:, - '4%;...�i. ii: f 6 15.6 8 - - - Z Z 7LB 28.0 23.7 20.4 17.6 15.2 7LB 26.3 21.8 18.3 15.2 11.8 7LB 24.6 Tz:{'?;:'%4,.0 11•:zl:>}j,;:., + 8.:.. ";<:'>` 7LB 21.0 15.7 8.7 w 8LB 42.8 37.4 33.4 30.1 27.5 8LB 41.4 35:9 31.8 28.5 25.7 LB 9£1(?•>,;.34`:t::'3, 25'i$:?`;,.,;:i7' 8L6 37.1 31.6 27.2 23.6 20.4 _j W m 9LB 51.8 47.1 42.4 38.6 35.6 9L6 51.8 45.8 41.0 37.2 34.1 9L6 ::: ;;: Q$„ ;?'i,; l;;; 35.8 .6 9LB 48.1 41.9 37.0 33.0 29.7 cQ 1 OL6 59.4 55.3 51.0 46.7 43.2 10L6 59.4 55.2 49.7 45.4 41.9 10LB>z,44.1 40.6 10LB 58.8 51.5 46.0 41.6 38.0 W/8 COLUMN HEIGHT W/ 10 COLUMN HEIGHT '_`'>://'f<.::.OL:T.ltlf'`#fGHT W/ 16 COLUMN HEIGHT MAXIMUM BEAM SPAN MAXIMUM BEAM SPAN z??;;±;;NJA #kM BEAR]F 3'AN MAXIMUM BEAM SPAN BEAM 4' S' 6' 7' 8' BEAM 4' S' 6' 7' 8' BE' 6' 6' 7' 8' BEAM 4' 5' 6' 7' 8' >SPACING 0 4LB - -- 4LB -- -- -- - 2;i: t;;;;':`.+�::>: ?.::::4LB ;;t:''vi::s: - - -- 4LB -- - -- - Q 5L6 15.3 10.2 - - - 5LB 11.8 5LB In 6LB 20.8 16.2 12.0 6.8 - 6LB 18.2 12.8 5.1 :">'ri:;'.;:: ?:;+; ;;:;ifr$ s. 15.3 '` 68 -- - 6LB 4.0 - - - - z Q 7LB 25.6 21.0 17.2 13.5 9.4 7LB 23.4 18.3 13.5 ;:;;<8:>; - '''t;'l8::` 21.0 15.3 7.9 - 7LB 15.8 - - J :E 8LB 41.2 35.6 31.4 27.9 25.0 8LB 39.5 33.8 29.4 37.8 32.0 27.4 23.6 20.3 8LB 34.4 28.2 23.2 18.9 14.3 9L6 1 51.8 45.6 40.8 36.9 33.7 9LB 50.6 44.0 39.1. �0-i 10L6 1 59.4 1 55.2 1 49.6 1 45.2 1 41.6 1 10LB 1 59.4 1 53 ;;.;.48.1 +43F 4E3;t ;`: ;; ; f : .59.4 52.2 46.6 42.0 1 38.3 1 10LB 56.9 1 49.3 43.6 38.9 35.0 TABLE APPLIES TO MANSARD, HALF MANSARD, AND A -FRAME FOR LARGER HEIGHTS SEE SITE SPECIFIC ENGINEERING. BEAM 4.0' 4 5.0' 5.5' >': >.;.;:;$f`':.. 6 S`';< z<r`::;0' 0 > SPA I G 4L 11.7 11.0 10.4 9;:s: ;<'?z:''::? 9.1 :+:`'r>::;:`` 8.5 8.2 C-5LV 14.5 3: 12.9 ::? '` : < :>:=.`z' 11.3 `.:1I1.9 10.5 .2 6 16.6 15.6 14.8{r<::;:. :s'`3$:s=%:'`<;>t :`111; B 18.6 17.5 16.6 _�<'::>i:>`:4?.>' 13.9 13.4 12.9 w 8LB 25.8 24.4 23.1;;:'_' z.=..'1.1:: .; ;:.?' 19.5 18.9 18.3 J 9LB 31.3 1 29.5 28.0 25`:>'r ;;i' 24.5 23.6 22.8 22.1 0 10LB 36.6 1 34.5 :;;:::;>:>$::... 31.2 "'; >?:9':'1 28.7 27.7 1 26.7 1 25.9 COLUMN HEIGHTS BASED ❑N<`A;"':7.:. FOR LONGER SPANS SEE SITk''sw§ '' `'r. R(MRING. NOTE, THIS TABLE APPLIES :fkz.$ CEN'$C A�� ..::::::A## %:;NON,• FEARING WALLS FOR HORIZONTAtK;;s`;4 N11. LO�t}?'`i: ( i A.DESIGN. M PRO .k£`f3F,> b d tl tz Lli?5{1r;' <... 2.0 4.0 0.100 0.046 5L6 LAP i*EA�11; 2.0 5.0 0.116 0.050 6LB LAP BEA.,iS& , 2.0 6.0 0.120 0.050 7LB LAP BEAN: 2.0 7.0 0.120 0.055 8LB LAP BEAM 2.0 8.0 0.224 0.072 9LB LAP BEAM 2.0 9.0 0.306 0.082 10LB LAP BEAM 2.0 10.0 0.389 0.092 SCREEN BEAM SCHEDULES WITH FLAT ROOF UP TO 16' COLUMN HEIGHT MAXIMUM BEAM SPAN BEAM 4' 5' 6' 7' 8' 4LB 17.5 15.7 14.3 13.3 12.4 5LB 22.6 20.2 18.5 17.1 16.0 , 6LB 26.7 23.9 21.8 20.2 18.9 7LB 30.7 27.5 25.1 23.2 21.7 8LB 41.2 38.2 35.6 32.9,.,<<;: 9LB 48.8 1 45.3 1 42.6 1 10L8 1 56.4 1 52.3 1 49.2 FOR LARGER HEIGHTS SEE SITE BEAM SCREW SIZE # OF SCREWS : • (EA. ANGLE FACE) 8LB, 9LB, IOLB #14 6 ;:;':?;`;..• 6LB, 7LB #12 5 ...... 4LB, 5LB #12 2X3. #10 EEN ROOF FOR SCREENING WITH ❑PENINGS > 60% SPANS ARE FBC TABLE 2002.4 LOADS ARE APPLIED SIMULTANE (10 PSF LIVE LOAD) EXPOSURE B IMP❑RTANCE FRT: DESIGN MEETS L/60 DEFLECTI,If:` MAXMUM BEAM SPAR BEAM 4 5' 6' 7' 8' 19'::.. 10' 4LB 16.3 15.1 14.2 13.5 12.7 1 5LB 20.1 18.7 17.6 16.6 15.5 ."A. :: ; #:3:.; 6LB 23.4 21.7 20.4 18.9 17.7 1:<:.';t;a$'' >:1: 7LB 26.7 24.8 22.7 21.0,. 8LB 34.7 32.2 30.3 28.8.:'t2?:;..25.7 9LB 41.2 38.2 1 36.0 1 34.2'`>`.:°>;:<<;3.0 101 B 47.5 44.1 1 41.5 39.4 ,,.� : •,3 BEAM LOAD FACTOR = THE SUM OF E;.;..,SPAN OF"7;fiE;`.I;t] -:KS ... MEMBER NOTE, ANGLE MIN. LENGTH TO BE 2' LESS THAN BEAM DEPTH 2' X1/8' ANGLE EXIST. BLDG. L WF 16'.. 18, 20' >FACTOR BEAM LOAD w �o w 9.0 8.4 8.0 6.0 """ f'4 S 13.9 13.1 12.4 .3 20.6 19.3 18.2 17.2 23.2 21.9 20.8 29.0 27.1 25.6 24.3 ATTACHED TO EACH SIDE -OF THE CARRY BEAM. '1 Zzz1 LL/1/1/L/ _z 1X2 OR IX3 11 PURLIN MAX. TYPICAL PLAN DATE EA. SIDE (SEE SCHEDULE ' 03/13/08 i FOR CREW REQUIREMENTS) SCALE- S N.Y.S. )KALL CALCULATI❑NS BASED ON 6061-T6 ALUMINUM ALLOY MARRY R RY BEAM N, NSHE ii..++.+���M C DETAIL wwl/3 STRESS REDUCTI❑N NOT USED IN CALCULATI❑NS N.T.S. )KLINEAR INTERP❑LATI❑N BETWEEN COLUMN SPACING IS ALL❑WED SCREEN FABRIC DETAIL SHEET: PER F,B,C, 2004 EDITI❑N, W/2007 AMENDMENTS, EXPOSURE "B", 140 MPH SCREEN BUILDERS �D�C�T'ETGINEER FAI, U . 0050662 Z Q a- w Q r-t NOTE, 7'-0' MAX END BAYS (PURLIN SPANS ONLY) \ ALUM. K(CKPLAT,E }� D ` OPTIONAL. USE/ 202 TOP `& ATTACH,�KICKPL"ATE W/ 1-#2 @ 24' O/C CTYP.) U► n �- n o N� c L� d m - w to I z O ('1 C%) 1--t o U 7 F- n: a c1 L (U o ,» o J 7 U � n(U �WUa b b �u 3 '>v4) r` O W U - In Z a• ., z a r W g 0 U In zz�N L 0 3� �Dn N }l}� Wy1 «5i r�A� '-' w (n L 2E¢ .. (IN Q 'Z, ZX b 6 136 z m ¢ W n (L = � ` '- (L �rpiar .I of N 0 YP' 0 TYP. N DTYP' 1.01 1X2 1X3 202 BEAM TYPE t, to 4LB .100 .046 5LB .116 .050 6LB .050 7LB .120 .055 8LB .224 .072 9LB .224 .072 9LBH .306 .082 LOLB .389 .092 COL. to 55' N u� TYP. If] 55' T, P. GUTTER E-GUTTER 0 #14 TEK SCREWS FOR 7LB t , OR LARGER DR #10 S.M.S. z FOR 6LB OR SMALLER @ 18' C.C. TOP $ BUT. vl c < 072 6 � 0 4LB,SLB 6LB,7LBQ 8LB,9LB,9LBH 3X3X0.072 10LB LAP BEAM (303) COLUMN ANCHORING DETAIL IX3 PAVERS OR TILES OPTIONAL 33 FR M G � I iii T❑ B T I ,) � 3. 1 p P ���iiii zo x 12'X8' FTG. W/1-#5 •r 12 STRIP FTG. DETAIL W/ PAVER OR TILE 11 12'X 8' FTG. IS MINIMUM FOOTING SIZE. REFER TO SITE SPECIFIC PLANS, AND STRIP FTG, SCHED. FOR ANY ADDITIONAL REQUIREMENTS. MIN. FOOTING SIZES SHOWN APPLY TO NEW FOOTING'S ONLY. FOR EXIST, FOOTING'S If -SEE COLUMN COL FINISH GRADE 3' FROM SODDED READ, TO BOLT FOR EROSION PROTECTION I. , • 3' 2' MIN.* COVER NOTE - THIS DETAIL IS APPQJ-1 AND MUST BE ACCO" SPECIFIC CALCUL'A``il* 51 /2 4 N .050' m `r N 070 v O55' 0,51" .. 2.0' 2.0' FACIA 2X3X0,050 2X3X0,070 D❑E>>1MB 2X4X0,050 :.....:..:..... o L- ni 5.094' , 0 cU FOR COLUMNS A' OR GREATER INST' ADDITIONAL 2'X2'Xl'f ANGLE EA.: SI OF I DE OF C 3' TO 4.0' 3.0' � ,064' N w TYP. o 0 ,I .125' ,050' 1' TYP. N TYP. 2X2 21 0' 2.0' .,. C 2X3 3X3 ` 2 4 ' 3X2 4X4 2X5 FOR 4' & 5' COL. USE 2'X2'X2' LONG X 1/8' COLUMN SCHEDULE (FOR OPEN , WALLS' ; ; #k<j. ALUMINUM ROOFS) ANGLE EA. SIDE OF COL TABLE GIVES MAX. COLUMN HEIGHT FOSi? R:rftL�`Jk;''{J1;�1MN. SGJEf3';QD2I3.. BEAM LOAD r> u1L -' •.. W/ 3-#6 TO COL. & 1 3/8' X 4' LG, TAPCON 2' LI TO CONC @ EA. CLIP "f'?'''' 'O O 2'X2'X2' LONG X 1/8' ANGLE EA. SIDE OF COL. O O W/ 4-#6 TO COL. & 1 - 3/8' X 4' LG, TAPCON ::O•- TO CONC. @ EA. CLIP O n! %4-#6 TO C❑L. (TYP) CLIP ANGLE COL. / 1 - 3/8' X 4' LG. TAPCON TO CONC. (TYP.) #3 @ 18' O.C. ELSEWHERE DELETE IX2 FOR OPEN PORT CTYP.) 3' FROM EDGE TO BOLT <MIN,) _ 3:y;> 31 , NOTE,S ANGLE ARE NOT REQ'D. FOR 202DOOR JAMB COLS. E a c MN T 7H_ CONCRETE TO BE 2'X2'X1/8'X2' ALL ANGLES SECURING THE COLUMN ❑ SLAB LONG, USE ONE ANCHORS PER CLIP -MIN. TWO ANCHORS PER COLUMN IN AL W.W.M. 1 8' G 5 Y K T' aka TAPCON ANCHORS, 3/8' DIA. BOLTS MAY BE 'ASHLE QUIC SE (SEE ANGLE TO CONC. DETAIL) ..S.LA 1Ef . PA V R R TILE A R SEEGENERAL NOTE 4 FOR ADDITIONAL REQUIREMENTS,- LIEU OF 6X6 10/10 W.W.M. GENERAL N❑TES:';"<:`<' &TESTED -IN ACCq.RDANCE G`x'..THISSTRUCTURE HAS BEEN DESIGNED N INCLUDING THE 2007 AMENDMENT '�: - -.'j, F,B.0 2004 EDITION I DI 5.,; fiF:.P1i...ME... T W/ LATEST ED. ❑F HE ALUM, CO IN ACCORDANCE E DESIGN 7- TO THE S CRITERIA OF THE ASCE 02 -SEE COLUMN ANCHORING DETAIL COL. N - ' 0 M.P.f♦%C >EB) WIND LOAD 14 � RIMW C❑LUMN TYPE 3X3X,090 - - - 1.52 K - L.5 I COL. SPACING 6 9 � .� :.::.:..:.: .. .:: ,.: ,: 16 17 18 19 2 0 4 21.3 19.1 17.4 16.1 15.1 .1?tt ::. 13.5 ":i29 ;:# ; ':`.. 11.8 11:4"" 11.0 10.7 10.3 10.1 9.8 9.5 5 19.1 17.1 15.6 14.4 13.5:; St i '::';.12.1 11; is'i > ." :::`i:::C`10.6 10.2 9.8 9.5 9.2 9.0 8.7 8.5 6 t7,4 15.6 14.2 13.2 12: :'t:: < i'1::::: F'.% : 0 105'+ f:::#4r S'i::' .ia7: 9.3 9.0 8.7 8.4 8.2 8.0 7.8 7 16.1 14.4 13.2 12.2 11.4 `:'::1 '> f':?`ir 0` ::: 9,7 8.6 8.3 8.1 7.8 7.6 7.4 7.2 8 I5,1 13.5 12.3 11.4 10 7 8 '?:+;;'r > ' 8.1 7.8 7,5 7.3 7.1 6,9 6.7 9 14,2 12.7 11,6 10,7 10.1 ':, 8,2 :: .9 7.6 7,3 7.1 6,9 6.7 6.5 6.4 10 13.5 12.1 11.0 9.0 ;.. 7.8 ' 7,5 7.2 7.0 6.7 6.5 6.4 6.2 6.0 11 12.9 L1.5 10.5..::;?:' Y si `?;;:. 8.6 Y .i8 i%t?.:7.4 7.1 6.9 6.6 6.4 6.2 6.1 5.9 5.7 12 12.3 t1.0 1 :`::?::;:i ` :::i':`$i`;?'s. 8.2 7:Sf i:$::>;;<:::I: 1 68 6.6 6.4 6.2 6.0 5.8 5.6 5.5 14 11.4 10.2 :: :? ''Ci.;£'.:i;$!£'�.>; 7.6 7.2 ":s'!8:9v: 6�6 6.3 6.1 5.9 5.7 5.5 5.4 5.2 5.1 16 10.7 9.5 <. i$li%%':'8.1 "' i5s"s; 7.1 6.7 ix4'' 6.2 5.9 5.7 55 5.3 5.2 5.0 4.9 4.8 18 10.1 9.Qi ::% ? 7,6:;:::f'. `;;:'%a ?>' :3r::. 4 6.1 5.8 5.6 5.4 5.2 5.0 4.9 4.7 4.6 4.5 20 9.5 :.7 :':''?.:'>: '::.?<:: S<. ". <::.<.:';; 'Q:x 5,7 5.5 5.3 5.1 4.9 4.8 4.6 4.5 4.4 4.3 LUMN'`< E +C�"fil']PEN WALLS W/S❑LID ALUMINUM ROOFS) 1'pE GIVES:p}Al 1T#tIMN HEIGHT FOR GIVEN COLUMN SPACING AND BEAM LOAD C❑l'lit1YP..E1 4X4`X{3:Qi:%'i%`::.. LOADING = 33 PSF AREA = 1.45 K = 1.5 I = 3.70 4 :'J�,+z'j:% : 6 J „....,"C3 9 LO Il 12 13 14 15 16 17 18 19 20 7.':•. 5.1 ''23.5 22.1 21.0 20.0 19.2 18.4 17.8 17.1 16.6 16.1 15.7 15.2 14.9 .64:. k+22.5 21.0 19.8 18.8 17.9 17.1 16.5 15.9 15.3 14.9 14.4 14.0 13.6 13.3 1 17.8 16.7 15.9 15.1 14.5 13.9 13.4 13.0 12.6 12.2 11.8 11.5 11.2 '8::; �ib `:: . � `:: ;2' 17.8 16,6 15.7 14.9 14,2 13,6 13.0 12,6 12.1 11.7 11.4 11,1 10.8 10.5 9''%';#i 16.7 157 14,8 14,0 134 12.8 12.3 11.8 11.4 11.1 10.7 10.4 102 9.9 10 '`::z; :1 : ; s' ;$::: +' 17.1 15.9 14,9 14.0 13.3 12.7 12,1 1L7 11.2 11,8 10.5 10.2 "'c114d k .'i 16.4 15.1 14.2 13.4 12.7 12.1 11.6 11.1 10.7 10.3 10.0 9.7 9.4 9.2 9.0 !%12 15.7 14.5 13,6 12.8 12.1 11,6 11.1 10.6 10.2 9.9 9.6 9.3 9.0 8.8 8.6 14 .;• %'15,9 14.5 13.4 12.6 11.8 11.2 10.7 10.2 9.B 9.5 9.2 8.9 8.6 8.4 8.1 7.9 .. 16.6 14.9 13.6 12.6 11.7 11.1 10.5 10,0 9,6 9.2 8.9 9.6 8.3 8.1 7 .8 7. 6 7.4 14.0 12.8 11,8 11.1 1 .4 9.9 9.4 9.0 8.7 8.4 8.1 7.8 7.6 7.4 7,2 7.0 13.3 12.1 11.2 10.5 9.9 9.4 9.0 1 8.6 8.2 7.9 7, 7.4 7.2 7.0 6.8 6.6 S OF THE ALUM. ARE CONFORMS 3' FROM EDGE SCREEN WALL &SCREEN Rsi'?':QfIDS BAS1>;+i(f61% SCREEN OPENINGS T❑ BOLT (MIN.) �..;; ALUM. PAN &INS A PANEL VE LOADS IMPORTANCE FACTOR = 0.77 INISfi"'Fi12ADE N R ❑T R POSITIVE 1. ALL PRIMARY MEMBERS WILL BE CO NECT� { }$, POt S ❑ HE FASTENERS, ,::.. z I'WOER FOOTINGS. 2. ANCHORS SHALL BE PLACED. ::%ft1F`:`':THA[a 3''E#::.OF CONCRETE SLAB 0 f °° .:<: :. .. ALL CONC. FASTENERS MUST; <i .' ?1 D, A,.,Al %NTO SOLID CONC. REGARDLESS ❑F zo LENGTHS SPECIFIED IN FNj11IC1AL'A7A:{I::?s;;;: 4' CONC. SLAB '"`.... ' 8' W/ 6X6 - 10/10 W.W.M. 3. FASTENERS FOR ALUM. SH SHl:XGD 8'`:'TIN CENTER W/ 8'X8' FTG. W/ 1-#5 4. FASTENERS SHALL HA' V 1 AD At4`11/t$f2 %:-. ?*P97VIDED W/ 1/2 INCH DIA. WASHERS MIN. 5. CONTRACTOR IS RESPOPI9'.'*'* TO INSJLAT .:;A0 MEMBERS FROM DISSIMILAR METALS TG, & SLAB DETAI TO PREVENT E;L CTROLY 6. ALUM. IN CII vT t:±%<W/ CC{i C 4 '' }{ F 7 .':• : tT1 L '' BE PROTECTED W/ HEAVY BOOTED BITUMINOUS NOTE-FIHERMESH MAY BE USED IN LIEU OF 6X6 10/10 W.W.M. .. :>:..:..,sz'''" A BE PAINTED W/ TWO PAINT ❑R Vf `:=>:`'.t#: E M ':`. # ACQUER ❑R THE WOOD SHALL ;4..�[2.....I.T �. 7++::<< T W/ A GOOD QUALITY CAULKING, COATS OF AL ."N'-' ` ' ,:::• AINi``A'. .. J❑IN S SEALED NOTE Fi<>AkA FOR CLfiMNS 5' DEEP OR GREATER INSTALL COL. 2'X3'X3' LONG X 1/8' 7. ALL DOORS TO'";i:5_FwGLOSING AND LATCHING, W/5 FT. HIGH DOOR HANDLES WHERE POOL OR APPLIC�%'f3'<7:*f:%;}p';;`.;;Q' ADDITIONAL 2'X2'X2'Xl/8' ANGLE EA. SIDE 2, 2, ANGLE EA. SIDE OF WIDE tfi' >l{1iRY OF INSIDE OF COL. W/ (3)- #12 X 1 LG COL. W/ (6)-' #12 X I' 1'.::;:j.r.':.;S.M.S. TO COL. & (1)- 1/4' X 2 1/2' LG. TAPCON LG. S.M.S, TO COL. & 8' :.:7❑ CONC. @ EA. CLIP O <2)- 3/8' X 2 1/2 LG TAPCON TO CONC. #12 X 1' LG, S.M.S. TO COL, (TYP) N @ EACH CLIP. CLIP ANGLE COL, (2)- 3/8' X 2 1/2' LG. TAPCON cu TO CONC (TYP.) 4 PER COL„ f ` L/4' TAPCON @ 18' BE 1X3 1X3 O.C, ELSEWHERE z i AL '•s FTG. l ' M :t?c1S 2• 3' FROM EDGE 3' 2' ?YT.. . BETWE2ENi'::: `....:. ... DELETE 1X3 FOR MIN. ❑PEN PORT (TYP.)FR❑NT MI FASTENERS.>:,•': ELEVATI❑N COLUMN ANCH❑RING DETAIL NOTE: ANGLES ARE NOT REQ'D, FOR 202 DOOR JAMB COLUMNS. 3/8' DIA, BOLTS MAY BE 'ASHLEY QUICKSET', nka TAPCON ANCHORS. 202 DOOR JAMB PLACEMENT IS OPTIONAL. ALL OTHER COLUMNS IN SITE -SPECIFIC PLAN SUPERCEDES ANY REQ:S SHOWN ON BUILD To Y W/ LOCAL ING CODES. -INiS.�:.::C„�i��3MN ,. ......AL, 6 _XTR'' .1tS .........................061-T6 ..CIA L. 6 IEE66 `14k..RIVETS, WASHERS ,.....AL. 2024-T4 =NETS TO BE ALUM„ NON-MAGNETIC "STEEL, OR CADMIUM PLATED STEEL xUNLESS ❑THERWISE NOTED GENERAL DETAIL SHEET: PER F,B,C, 2004 EDITI❑N W/ 2007 AMENDMENTS, EXPOSURE "B" STRIP F❑❑TING SCHEDULE CARRY BEAM SCHEDULE (FOR S❑LID ALUMINUM ROOFS) TABLE GIVES MAX, BEAM SPAN FOR GIVEN BEAM LOAD m BEAM LOADS FOR ALUMINUM ROOFS = L/120 EXPOSURE Bix <10 PSF LIVE LOAD) �a BEAM 4' 6 6' 7' 8' 9' 10, 12' 14' 16' 18' 20' 2X4 10.3 9.6 9.0 8.6 8.2 7.9 7.6 7.1 6.8 6.5 6.1 5.8 2X5 12.4 11.5 10.9 10.3 9.9 9.5 9.1 8.6 8.2 7.6 7.2 6.8 4LB 8.9 8.3 7.8 7.4 7.1 6.8 6.5 6.0 5.6 5.2 4.9 4.6 6LB 11.1 10.3 9.7 9.2 8.8 8.4 8.0 7.3 6.8 6.3 6.0 5.6 6LB 12.9 11.9 11.2 10.7 10.2 9.6 9.1 8.3 7.7 7.2 6.8 6.4 7LB 14.7 13.6 12.8 121 11.3 10.7 10.1 9.2 8.6 8.0 7.5 7.1 8LB 1 19.1 1 17.7 16.7 15.8 15.1 14.5 14.0 12.8 11.9 11.1 10.5 9.9 9LB 22.6 21.0 19.8 18.8 18.0 17.3 16.7 15.5 14.3 13.4 126 12.0 10LB 26.1 1 24.3 1 22.8 1 21.7 1 20.7 19.9 19.2 18.1 1 16.7 15.6 1 14.7 1 4.0 F❑❑TING (MIN.) STRUCTURE REBAR WIDTH X DEPTH SCREEN ROOF 12' X 10' 1-#5 W/ UP TO 7LB BEAM SCREEN ROOF W/ 8LB 12, X 12, 2-#5 SCREEN ROOF W/ 9LB 12, X 16, 2-#5 SCREEN ROOF W/ 10LB 12' X 16' 2-#5 ALL SOLID ALUMINUM 12' X 12, 2-#5 ROOFS MIN. FOOTING SIZES SHOWN APPLY TO NEW FOOTING'S ONLY. FOR EXIST. FOOTING'S SEE SITE SPECIFIC PLAN. 140 MPH I SCREEN BUILDERS > X: w U. I . COLUMN SCHEDULE (FOR S❑LID ALUMINUM ROOFS WITH SCREEN WALLS) TABLE GIVES MAX, COLUMN HEIGHT FOR GIVEN SPACING z WIND LOAD = 30 PSF ROOF, 21 PSF WALL EXPOSURE B -a COL. TYPE 4.0' 4.6 5.9 5.5' 5.0' 6.5' 7.0' 7.5' 8.0' 4LB 10.7 10.1 9.6 9.1 8.7 8.4 8.0 7.8 7.5 5L B 13.6 12.8 12.2 11.6 11.1 10.7 10.3 9.9 9.5 6LB 15.9 15.0 14.2 13.5 12.9 123 11.8 11.3 10.8 7L3 17.9 16.9 16.0 15.2 14.5 13.8 13.2 126 122 8LB 25.0 23.6 22.4 21.4 20.4 19.6 18.9 18.3 17.7 9LB 30.4 28.7 27.2 26.0 24.8 23.9 23.0 222 21.5 10LB 35.7 1 33.7 1 32.0 1 30:5-1 29.2 28.0 1 27.0 26.1 1 25.3 oa UO x ❑ Iw )x J ❑ U x J U ❑ zz wW J W f3 ww �_ 0 U a ¢C3 ❑a J U >ALl �;.. DATE, 03/13/68 n�- W �a �o p (U., a \. ,d - SCALE,. N.T.S. •m �-rsr� F� m I ''m c r'-KI cl 7 U kN J t\ti,N S� SHETI C Nb O W zV > :3 � i z �- 1-1 7 +' U 3 F ON If) u 6 f Z Z N¢ of J 0¢ 5a C.T. TARNOWSKI, P.E. W W rl IL _ H r STRUCTURAL ENGINEER - FIA. UC. 0050662 IL � r dr