Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE FILED: PLAN REVIEW FEE: RECEIPT NO.: PERMIT NUMBER: 001v CONCURRENCY FEE: RECEIPT NO.: CERT_ CAP. NO.: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. -Lucie County Building and Zoning 2300 Virginia Avenue � Ft. Pierce, FL 34982-5652 AYNE® 772462-1553 �UCAB cp linty APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION I . LOCATION/SITE ADDRESS: 5 S Lt.� �ZTT, C l4- P&A C EI% FlL 2. S/D NAME: SITE PLAN NAME: . 3_ PROPERTY TAX ID #: . ` q.16- 9623— o03,5 - 060 — 4_ LEGAL DESCRIPTION (attach extra sheets if necessary): Pffi&600P, P-IDCn5 " PL A-7" c9 — J LL/Lt-6rO H*j V pub 6 rr U N r•r i-2- (Gj- F 9 3 '-13 i 7 1 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. NO. NO. 9. PARCEL SIZE: ACRES/SQ FT. LOT DIMENSIONS 10. DESCRIPTION OF CONSTRUCTION PROJECT OR WORK ACTIVITY: 6 A n E , lF P'`r� ()UF TD L�)kz CGeJlu Uv 1 ,1j<&,Z—f7O,j kP� RUPA)IC4k,� A& tTl 6:4'ttda� 11. SETBACKS (ACTUAL) FRONT: BACK: RIGHT: LEFT: SIDE SIDE 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) [ ] NEW CONSTRUCTION [ ] EXPANSION/ADDITION [ ] INTERIOR RENOVATION [ ] RESIDENTIAL C.T1 COMMERCIAL [ ] INDUSTRIAL [ OTHER (SPECIFY) /N CprJ W l 77-f C�*41)(= 13. DESCRIPTION OF PROPOSED USE: 14. Sq. FtJCONSTRUCTION: 15. Sq. Ft. 1 st Floor: 16_ VALUE OF CONSTRUCTION: $ on � The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 OWNER -INFORMATION NAME: ADDRESS: l 5��fif off: .CITY: Q'[ l/ln C i STATE:.. L ZIP y fir/ t) ('DAYTIME): Q� 36 �" 65�`71 PHONE AYTIME _ � email:IF THE THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: _ ZIP PHONE (DAYTIME): U CONTRACTOR INFORMATION ST. of FL REGJCERT #: C CC . 0 36A, -70- ST. LUCIE" COUNTY CERT. #: BUSINESSNAME: %�0 r✓!.� iT , �1�J �- QUALIFIERS NAME:,i}� ADDRESS: 3 3 -7 I �✓✓ �%� °�� �� CITY: l+t-1y\ C I " STATE: il_� ZIP g PHONE(DAYTIME): -2-,F-7— 04FAXNO.(?_7)-J--l_ �� email: hi}j J4&-)m+,J 4DF1.1 &_e_ ARCHIT/ENGINEER: " ADDRESS: CITY: PHONE (DAYTIME): I BONDING COMPANY: ADDRESS: . CITY: MORTGAGE LENDER: ADDRESS: CITY- STATE: ZIP STATE: ZIP STATE: "- "" ` ' ZIP IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification it will be voided and returned to you by mail. t CERTIFICATION: J This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, ETC., not otherwise included with this building permit application. The -following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all -types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANTf AS THE APPLICANT FOR THIS BUILDING. PERMIT, IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT • AS A CONDITION OF THIS PERMIT YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning: OWNER/CONTVACTOR SIGNATURE CON CT SIGNATURE STATE OF FLORIDA STATE OF FLORIDA COUNTY OF-3 T, COUNTY OF The foregoing instrument was acknowledged before me this "`"Oday of &v t- 20g.- by who its ners9naLT known to me or who has produced ® as identification. Signature of Notary The foregoing ins 2ment was -acknowledged before me this 2.�! day of `I- , 2QW, by who is personally _kn� o me or who has produced as identification. Signature ofNotary Type or Print Name of Notary Type or Print Name of Notary "Xi" Commission No.d 0 5 py�3 (Seal) ' �= �Ri�l- MEDDD,90425W3 Commission No. �'�r :"""' Q�CQ�Iw►L MELDAU MY COMMISSION _ . �ISSION # DD 5042a EXPIRES: Februar�.. EXPIRES: February 12,2010 Bonded Thru NOW Pubi'�;R�,h�• Bonded 7hm Nokffy Mc UtMeir ra NOTE: TWO (2) SIGNATURES ARE REQU MUST BE NOT ZED. IF MMLYI THIS BUILING PERMIT AS AN OWNERIBUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. For specific instructions see appropriate permit checklist. Date: 1 Fee Due: Receipt#1, .1 i i'rrmit # (7V. 1. 2. St. Lucie County Building & Zoning -� 2300 Virginia Avenue. Ft. Pierce, FL 34982-5652 4' • Tel. 772-462-1553 APPLICATION FOR ROOF PERMIT SEE REVERSE SIDE FOR INSTRUCTIONS Location/Site Address: S 79 . Nw Sw�� y C /le 846n C I gj fC 3Y9 Parcel ID- Number: Office Use Only .. Section FTdwnshig Range I.Map Page. I Zoning Land Use Initials- ,% ;( S. �� 3. Description of Projector Work Activity: CONClzEww- 7'ltc RFROPF 4. Total Roof Area (square feet):. goo _ 5. Roof Pitch: tpAI 6. _ Type -of Roof:- --_❑-Fiberglass-Sbingle- -- ---- Bairrel/-Tile-Cer-amic - --- ❑- Wood-Shake'�hingle -- -- - -- ❑Tar &Gravel ❑Modified Bitumen ❑ Metal El Other (specify) N.O.A -Product Approval required for All Types of Roofing Material ❑ All Commercial Roofing Requires Design by an Engineer or Architect (two Sets) _. 7. Owner Information Name: M MARILL nl tocm> Address: 1579' Nw sWEE-rR4 y Ciie City: T AL rv1 C ITy State: Ft - Zip.: .3 t%��0 Phone: 336-057/ 9. Value of Construction: $ 8. Contractor Information FL Reg/Cert #: CCCA0--?0 7D-- - County Cert#: Bust ess Name: /OrOd Q OOFIrJ 6-I N G 072 Phone-a8'� 01 (Fax Note: Dlry-iu and Final Inspection Required. Additional inspection maybe' ay be'Tequired per Product Approval OWNEA'S AFFIDAVIT: I certify that all of the information contained in this a lication is correct 1 tilt 11 k in b d pp an a a wor wi a one in compliance with all applicable laws regulating constructi coo g. PRINT QUALIFIERS/OWNERS NAME SIGNATU OF QUALIFIER/OWNER STATE OF. FLORIDA, COUNTY OF /%%r[o.v ACKNOWLEDGED BEFOR$ ME THIS-�_ DAY OF 20d� BY _11,WHO IS.PERSONALLY IWOWN TOME OR WHO JlAS PRODUCED..-,. _ As IDENTIFICATION. SIGNA F NOTARY TYPE OR PRINT NAME OF TARY : a�Y %s CORINA L MELDAIJ «0. - MY COMMISSION # nn 504253 TITLE: NOTARY PUBLIC COMMISSION NUMBER EXPIRES: February 12, 2010 St. Lucie County Roof Permit Application rev. 7/18/05 dmg � p,'f;fc;R'`` BondedThruNoteryPublicUnderwriters 0 J NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXEMPT: A/C - HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. :INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. This roof permit application is to be -used only for those activities that are'not otherwise included under a primary building. permit. This application may not be used for any activity that includes structural alteration. BuiIdmg.activities involving structural. alteration; in addition to the roof.work, must.be permitted through the regular building permit review process. The information to be provided with this application includes: 1. Location/Site Address Indicate the street address or -.general location of the property where the building activity is taking place. 2. Parcel ID Number Indicate the tax identification number of the property where the building activity.is taking place. 3. Description of Project or Work Activity 4. Total Roof Area 5. Type of Roof 6: Owner Information 7. Contractor Information 8. Value of Construction Briefly describe the building activity to take place. Indicate total roof area to be affected by this permit. Also indicate the pitch of the roof, expressed as a standard ratio of run rise. Indicate the type of roof being repaired ;oi _resurfaced. Indicate the name `and address of.:the owner'of the property on which building activity;is taking place. . Indicate the State of Florida registration number (if. applicable), St. Lucie County contractor license number and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the buildirig/construction aetivity: Construction value it used to determine the permit*fee. St. Lucie County reserves the right to question and/or modify . the indicated value of conkiuctioii if it is demonstrated that the submitted figures are not corisistent with similar types of construction. This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. lva applications will be accepted for processing after 4:30 P.M. For assistance in completing this application; please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. '' Uponissuanceof this permit,,�required inspections can be scheduled by calling (772) 462-1261. St. Lucie County Roof Permit Application rev. 7/18/05 dmg JMK CONSTRUCTION, INC 3795 SW SAVOY DRIVE PALM CITY, FL 34990 (772) 286-0755 FAX (772) 283-6422 LICENSE CBC 059558 Re :201.3.4 Prescriptive method for hip roofs on a masonry wall Sufficient corner eave sheathing shall be removed from the side of the hip ridge parallel to the roof ridge to provide access to a minimum 6 foot length of exterior wall. The hip ridge board and any exposed rafters that are not anchored with a strap having at least 4 fasteners on each end, shall be connected to the masonry wall below using approved straps or right angle brackets with a minimum uplift capacity of 500 lbs. Adding fasteners to existing straps shall be allowed in lieu of adding a new strap provided the strap is manufactured to accommodate at least 4 fasteners at each end. The straps or right angle brackets shall be installed such that they connect each rafter or truss to the top plate below or directly to the masonry wall using approved masonry screws that will provide at least a 2 %2 inch embedment into the concrete or masonry wall. When the straps or right angle brackets are attached to a wood sill plate, the sill plate shall be anchored to the concrete or masonry wall below. This anchorage shall be accomplished by installing 1/4 inch diameter masonry screws, each with 1/4 inch washer, with a sufficient length to to have at least a 2 V2 inch embedment into the masonry wall below. These screws shall be installed within 4 inches on both sides of the truss or rafter. Jobsite: Buckley Residence 1578 NW Sweetbay Cir Palm City, FL 34990 k 1A04VO4 Steve Diapoules President J.M.K. Construction Inc. St. Lucie County Building -& Zoning 2300 Virginia Ave Fort Pierce, FL 34982 BUILDING PERMIT SUB -CONTRACTOR SUAMARY . will be using the following sub -contractors for the (Company/Individual Name) /� /, project located at 5' I W 5 L`�EC-7—C'/tv PAC in C /7Zj (Street -address or Property Tax ID # ) It is understood that if there is any change of status regarding the participation of any of the sub -contractors listed below, I will immediately advise the Building and Zoning Department of St. Lucie County. Trade--. Name of Company/Contractor St. Lucie County/ State of Florida License Number Electrical Plumbing HVAC/ Mechanical - Roofing Gas lU��tCA�r� 'TMK Cd F40H Co-", PC 13v990 IIPERMIT I .I ISSUE DATE: NUMBER: ST. LUCIE COUNTY PUBLIC WORKS BUDDING & ZONING DEPARTMENT BUILDING PERAM SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number:�o`� 1 State of Florida Certification Number. (If applicablc): C BC 0 5CI 5 5-8i m K (- © , � Sim UEA) h /I Pig 0 L. ES have agreed to be the (Company Name/Individual Name) M n' I&Pr-OD4 sub -contractor for )qE4776N P-06,.P1Af L) /,ti G (Type of Trade) (Primary Contractor) for the project located at ) 5 7$ NW C 1 ,1N pt,-n C&, pL _ (Project Street Address or Property Tax ID #17 If is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) DUSMS S QUAD+ IER (Name of the Individual shown on the Contractor's License) OPJdMAL SIGNATURES ARE REQUIRED SIGNATURE PRINT NAME DATE Business Name: Cd N5 T P U CT"1 Ur l ; j :U Address: 3 %�f S kJ Shy 1� )y City/StatelZip: PALM - C i n aP-L 3 _cj q 0 _ -Phone: (-77A -2 ? 6 — 0 % 5 S email: 0 4 EDW1N M. FRY, Jr., CLERK OF THE CIRCUIT COURT — SAINT LUCIE_COUNTY FILE # 3189252 OR BOOK 7 PAGE 802, Recorded 04/03/20C� ";t 02:56 PM _1 The undersigned hereby given Florida statutes the following I 1. DESCRIPTION 2. GENERAL DESCRIPTION 3.OWNER INFORMATION: b. Address of 5 ff NAJ d. Name and address of fee siml 4. CONTRACTOR'S NAME, A] 5. SURETY'S NAME, ADDRESS 6. LENDER'S NAME, ADDRESS 7. Persons within the State of Florid Section 713.13 (I)(a) 7., Florida S NAME, ADDRESS AND PHONE tt 8. In addition to himself or herself, C 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE N 9. Expiration date of notice of comm specified) Signature of Ownervor Owner's Authorized Officer/Diree State of Florlds County of, Sr/C L raJe The foregoing instrument was admor By %%7 &A-1 iL.i.✓ Au (Name of person) For key ^ (Ame of party on behalf of whoa (Printed Name of Notary Public) Under penalties of per)tny, I declare belief (section 92.525, Florida Statult �'�J //! Signature(s) of Ownerl y!i By: Z PXV.oanoneoroWW&!W (S ) 71115 Sparc 15; reui rM tor runeding im, M—TICEOFOOMNENCEMENT _ that improvement will be made to certain real property, and in accordance with Chapter 713, don is provided in the Notice of cotmnencement. . (Legal description and sheet address) TAX FOLIO NUMBER:yY.i(o' IMPROVEMENT: a. Name M wjt&-7-,0" C /!c' M "ry k 3 V9Rsc. interest in property G tv mek titleholder (if other than owner)_ N / 4 ItESS AND PHONE NUMBER: BEATON ROOFING INC. ND PHONE NUMBER AND B014D AMOUNT: Al ND PHONE NUMBER: A/ / %f- lesignated by Owner upon whom notices or other documents may be served as provided by htfo- MBER: _ AV / %- ner designates the following to receive a copy of the Lienoes Notice as provided in Section cement (the expiration date is 1 year from the date of recording unless a different date is 20' Print Name and Provide Signatory's Title/Office ;ed before me this 3 day of 11►,11�L 208 a, aw a r+ .00 (Type of authority... e.g. Owner, officer, trustee, attorney is fact) ntment was executed) Personally Known. , or produced the following type of ID: CORillll L ME1DAti �`'� `� MY COMMISSION 1 DD W42W (Signature ofNotary Public) (Scut) ' EXPIFIES: Fob=iy 12, 2010 eaidM 77ru pabrr Pibsc W�denrtRa I have read the foregoing and that the facts in it are true o STATE F FL RIDA or Owoer(s)' Authorized Otlleer[retct�r�rt�e Igsr who signed above: yT� 1 i T �!f 18 B T 1r° t 1 i t rrljkl.� CO DRLGIN L. tedN ' e) G r M- FRY, JR., ER1� s. r Date: Thursday, Apr 03, 2008 03:27 PM JMK CONSTRUCTION, INC 3795 SW SAVOY DRIVE PALM CITY, FL 34990 (772) 286-0755 FAX (772) 283-6422 LICENSE CBC 059558 April 21, 2008 S.T. Lucie County Building Department 2300 Virginia Ave. Ft. Pierce, Fl. (DSCA-(-)CDZA �kc �j v ApR?? ? sr. Avb lie �Og tiele Ciyo ove ks t3; ),� Re: Hurricane Mitigation - Buckley Residence,1578 Sweetbay Circle, Harbor Ridge -Palm City This letter is to inform you of the condition we observed at above address concerning truss tie downs. After removing plywood at the roofs edge, I discovered the structure was 8"cbs construction with a 8"x 16" poured concrete tie beam. Truss tie downs were 1/8" x 1"wide imbeded metal straps with (3) 16d common nails driven thru and bent over. We used Simpson N 10 engineered truss nails @ 11/2" long and filled every hole in existing strap averaging between 8 to 10 nails per strap .We took pictures of the work and re -nailed the existing 5/8" cdx plywood back as required on approved nailing schedule. kl,C4 6-� Steven Diapoules President JMK Construction Inc. Public Works Department Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 INSPECTION AFFIDAVIT RE: Permit # 0 $o q - 00 39 RECEIVED APR 2 '4 2008 Public Works St. Lucie County, FL I bfW 16-L &- J-10Q TJQA) ,licensed as a(n) ontracto /Engineer/Architect/ (Please print name and circle license type) F 68 Building Inspector* * General, Building, Residential, or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. All affidavits must include photographs of each plane of the roof with the permit # or address # clearly shown marked on the deck for each inspection. On or about �f g I O$ 02 3O .pM , I did personally inspect th roo (Date & time) eck nailing nd/or seconddry water barrier work at I Jr 7$ (circle one) (Job Site Address) SwE"Er� CIP—Clr P*Un C11---1, FZ- 3y Based upon that examination I have determined the installation was done according to the Hurricane X1 itigat�q etrofit Manual (Based on 553.844 F.S.) CC 03ro 9-70 License # STATE OF FLORID e COUNTY OF Sworn to and subscribed before me this /J: day of Ao,,'k 200_g by l+aPi _/_ /' Ae%►-/M�12 Who is personally known has produced as identification. Notary Public, State of Florid Signature of Notary: Commission No.: S � y A r:s '•"'% CORINA L MELDAU ;= MY COMMISSION # DD 504253 $eMPIRES: February 12, 2010 •�'�„P� ; ' BondedihmNotryPubl(eUndenvdters cm19/27/07 ,r Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce BUILDING PERMIT Issued: 04/03/2008 Conf #: 651 Permit #: SLC- 0804-0039 Job Location: 1578 SWEETBAY CIR City: PALM CITY Permit Type: Roof Job Description: TEAR OFF AND REROOF CONCRETE TILE 4800 SQ FT- 6/12P Subdiv: Harbour Ridge #8 E Hammock/Sweet Bay Lot: Block: Parcel: 4426-803-0035-000/9 Contractor HEATON DANIEL E Page 1 HEATON ROOFING INC (772) 287-0116 3371 SW 42ND AVE PALM CITY, FL 34990 Property Owner M MARILYN BUCKLEY (772) 336-0571 % MORTIMER J BUCKLEY OSTERVILLE, MA 02655-0411 Setbacks Left: Right: Number of Units: 1.00 Floors: 1 Minimum Floor Elevation: Job Value: $ 34,400.00 Front: Rear: Zoning: PUD Buildings: 1 Square Footage: 0.00 Flood Map: Flood Zone: Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as.water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucieco.gov/ce Date: 03 April 2008 Job Address: 1578 SWEETBAY CIR Received By: GERSTEML Paid With: CK Paid By: HEATON ROOFING INC Building Receipt Receipt M 0000061932 'ermit Number: SLC- 0804-0039 Amount: $230.00 �redit Card Number: Check Number: 3203 Sign: Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) •462-2522 Address City /;State / Zip Parcel # suture Land Use Issued Estate Permit Type Root 4pplication Type Qvei Activity Type Code Type •;• Account •;•. Quantity Amour Acce5653 06-Plan Review - Accessory Use - O' 491 2415 322000 200 $50.00 Acces653 06-Plan Review- Accessory Use - O' 4912415 322000 200 $E BIMS651, 06-BIMS 491 2415 322050 200 $j Permi755 06-Permit Fee - Roof - (1 Bi,2 Family 4912415 322000 200,. $i Permi722 '' 06-Permit Fee -Inspections (each) " 491 2415 322000 200' . �Permi722 06-Permit Fee -Inspections (each) 4912415 322000 200 $; )ate Entered 04103/2008 Date Paid 04/0312008 EnteredBy Idebbie Historical?' No e Posted 1 J -._. .. V41V41LVVi3 Yes 04/0412008 Yes . 04/04/2008 ° Yes 04/0412008' , Yes 1 04/04/2008 Yes Receipt#' Amount "` Date Posted 0000061932 $230.00 "° 04/04/2008 Paid By HEATON ROOFING INC •;• Payment Type l CK ��' Check (CK),Cash (CA) Check #' 3203 ?vlastercard (MC), Visa (VS), Fee Waived (FW), Refund (RF), Credit Card Number Reversal(RV) - jedit Card Autho,rizativn- Issued To HEATON ROOFING INC Received By GERSTEML M I A M I•DADE s BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIANII-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) Tamko Building Products, Inc. , P.O. Box 1404 Joplin, MO 64802 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described' herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TAMKO Modified Bitumen Roof System Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA #04-0506.03 and consists of pages 1 through 19. The submitted documentation was reviewed by Alex Tigera. NOA No.: 07-0111.03 Expiration Date: 05/23/12 3 Approval Date: 05/10/07 Page 1 of 19 FIL m- PY . to ROOFING SYSTEM APPROVAL Category: Sub -Category: Deck Tyne: Maximum Design Pressure Fire Classification: Roofing SBS/APP, Modified Bitumen Wood -60 psf See General Limitation #1 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Awaplan 170 FR Awaplan 170TM Awaplan Heat WeldingTM Awaplan Premium FRTM Awaplan PremiumTM Dimensions Roll weight: 98 lbs.; 33' 11" x 39 3/ " a Roll weight: 98 lbs.; 33' 11" x 39 3/ n a Roll weight: 96 lbs.; 25' 5" x 39 3/8" Roll weight: 101 lbs.; 33' 11" x 39 3/ " B Roll weight: 101 lbs.; 33' 1l" x 393/s" Test Specification ASTM D 5147 ASTM D 6164 Type I, Grade G ASTM D 5147 ASTM D 6164 Type I Grade G ASTM D 5147 ASTM D 6164 Type II Grade G ASTM D 5147 ASTM D 6164 Type II Grade G ASTM D 5147 ASTM D 6164 Type II Grade G sflwaflex Roll weight: 76 lbs; ASTM D 5147 35.9' x 36" Awaflex FR _4:: cqq. Roll weight: 76 lbs; ASTM D 5147 35.9' x 36" Product Description A 180 g/m2 polyester reinforced SBS modified bitumen'membrane surfaced with granules and treated for additional fire resistance. Applied in hot asphalt or cold adhesive. A 180 g/mz polyester reinforced SBS modified bitumen membrane surfaced with granules. Applied in hot asphalt or cold adhesive. A 250 g/m2 polyester reinforced SBS modified bitumen membrane surfaced with granules. Applied by torch and also used as a walkway material. A 250 g/mz polyester reinforced modified bitumen membrane surfaced with granules. Applied by hot asphalt and also used as a walkway material. A 250 g/m2 polyester reinforced SBS modified bitumen membrane surfaced with granules. Applied in hot asphalt or cold adhesive, and also used as a walkway material. SBS modified cap sheet constructed with a 155gm/m2 non- woven polyester mat saturated with asphalt, coated on both sides with SBS rubber modified asphalt and surfaced with ceramic granules for UV protection. SBS FR modified cap sheet constructed with a 155gm/mz non- woven polyester mat saturated with asphalt, coated on both sides with SBS rubber modified asphalt, FR treated, and surfaced with ceramic granules for UV protection. NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 2 of 19 Test Product Product Dimensions Specification Description Awaplan Versa- Roll weight: 100 ASTM D 5147 A 180 g/O polyester reinforced SBS Smooth lbs. 33' 11" x 393/8" ASTM D 6164 modified bitumen membrane. Applied in Type I hot asphalt, by torch, or mechanically Grade S fastened, as a base ply in 2 ply modified systems. Awaplan Versa -Flex Roll weight: 76 lbs; ASTM D 5147 A 170 g/mz nonwoven polyester reinforced 33' 11" x 39-3/8" ASTM D 6164 SBS modified bitumen membrane. Type I Applied in hot asphalt, as a base ply in 2 Grade S ply modified systems. Base-N-Ply® Roll weight: 72 ASTM D 4601 Asphalt impregnated and coated glass fiber lbs.; 97'-6" x 393/8" Type H base sheet for use in conventional and modified bitumen built-up roofing. Glass-BaseTM Roll weight: 72 ASTM D 4601 Asphalt impregnated and coated glass fiber lbs.; 97' 6" x 393/g" Type H base sheet for use in conventional and modified bitumen built-up roofing. Tam-CapTM Roll weight: 83 ASTM D 3909 Asphalt impregnated and coated felt lbs.; 32' 11" x surfaced with mineral granules used as the 393/s" top ply in conventional built-up roof membranes. Tam -Glass PrenuumTM Roll weight: 53 ASTM D 2178 Asphalt impregnated glass felt for use in lbs.; 161' 9" x Type VI conventional and modified bitumen built- 393/g" up roofing. Tam -Ply IVTM Roll weight: 44 ASTM D 2178 Asphalt impregnated glass felt for use in lbs.; 161' 9" x Type IV conventional and modified bitumen built- 393/8" up roofing. Type 43 Base Sheet Roll weight: 85 ASTM D 2626 An organic felt reinforced asphalt base lbs.; 72' x 36" sheet. Applied in hot asphalt or mechanically fastened. Vapor-ChanTM Roll weight: 86 ASTM D 4897 Heavy duty fiber glass base sheet lbs.; 32' 11" x impregnated and coated on both sides with 393/8" asphalt with or without a fine mineral stabilizer. Surfaced on the bottom side with coarse mineral granules embedded in hot asphaltic coating. Versa -Base FRTM Roll weight: 60 ASTM D 5147 Asphalt impregnated and coated glass fiber lbs.; 48' 2" x 393/8" base sheet for use in conventional and modified bitumen built-up roofing. Versa-BaseTM Roll weight: 94 ASTM D 5147 Asphalt impregnated and coated glass fiber lbs.; 48' 2" x 393/8" ASTM D 6163 base sheet for use in conventional and Type I, Grade G modified bitumen built-up roofing. Versa -Cap FRTM Roll weight: 87 ASTM D 5147 A fiberglass reinforced, mineral surfaced, lbs.; 33' x 393/8" SBS modified bitumen top membrane. Tam -Pro 846 Fibered 5 gallon ASTM D 1227, Protective coating. Emulsion Coating type 11 Tam -Pro 813 Quick- 5 gallon ASTM D 41 Asphalt based primer Dry Primer NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 3 of 19 Test Product Product Dimensions Specification Description Tam -Pro 842 Fire 5 gallons ASTM D2824, Flame retardant protective coating Rated Fibered type III Aluminum Roof oating APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) Pyrox, White Line Isocyanurate Insulation Apache Products Co. ACFoam Composite Isocyanurate Insulation with perlite facer Atlas Roofing Corp. ACFoam II Isocyanurate Insulation Atlas Roofing Corp. ConPearl Expanded perlite mineral fiber Conglas EnergyGuard Perlite Expanded mineral fiber GAF Mat'l. Corp. EnergyGuard Fiberboard Wood fiber board GAF Mat'l. Corp. Dens Deck Silicon treated gypsum G-P Products Sturdi-Top Wood fiber insulation board. G-P Products Wood Fiberboard Regular wood fiber insulation Generic High Density Wood Fiberboard High Density Wood Fiber insulation board. Generic Perlite Insulation Board Perlite Insulation Generic Armor Board Regular Fiberboard Wood fiber board Honeywell Int'l. Inc. Hubert Fiberboard Wood fiber board Huebert Fiberboard, Inc. ENRGY 2, ENERGY 3, PSI-25 Isocyanurate Insulation. Johns Manville Retro-Fit Board, DuraBoard A high -density perlite roof insulation. Johns Manville Fesco Board Rigid perlite roof insulation board. Johns Manville Kop-R Wood Fiber Wood fiber board Koppers Industries, Inc. Structodeck, Structodek FS High Density Wood Fiber insulation board. Masonite NOA No.: 07-0111.03 a r Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 4 of 19 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Dekfast Fasteners #12, Insulation fastener for wood, SFS Intec, Inc. #14 & #15 steel and concrete decks 2. Dekfast Hex Plate Galvalume hex stress plate. 2 7/8" x SFS Intec, Inc. 3 1/4" 3. #12 Roofgrip Fasteners Insulation fastener for wood ITW Buildex Corp. and steel. 4. Metal Plate Galvalume stress plate. 3" round ITW Buildex Corp.- 3" square 5. Olympic Fastener #12 Insulation fastener Olympic Mfg Group, Inc.. & #14 i 6. Olympic G-2 Galvalume AZ55 steel plate 3.5" round Olympic Mfg Group, Inc. 7. Olympic Standard Galvalume AZ50 steel plate 3" round Olympic Mfg Group, Inc. 8. Insul-Fixx Fastener Insulation fastener for steel SFS Intec, Inc. and wood decks 9. Insul-Fixx S Plate Galvalume AZ50 steel plate 3" round SFS Intec, Inc. 10. Tru-Fast Insulation fastener for steel The Tru-Fast Corp. and wood decks 11. Tru-Fast Plates Galvalume AZ55 steel plate 3" round The Tru-Fast Corp. EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date Factory Mutual Research Corp. Comparative Rupture Testing J.I.4DOATAM 10.21.98 Class 1 Fire J.I.OZ4A3.AM 08.27.97 Class 1 Fire; 1-90 Windstorm J.I. 1D4A7.AM 10.20.97 Class 1 Fire; 1-90 Windstorm J.I. 3B5A9.AM 08.27.98 Exterior Research & Design, LLC Wind Uplift Testing 4444.06.98-1 06.15.98 Wind Uplift Testing 4449.08.99-1 08.03.99 NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 5 of 19 ' ~1 APPROVED ASSEMBLIES: Deck Type II: Wood, Insulated Deck Description: Minimum 15/32' or greater plywood or wood plank. Plywood shall be attached to 2" x 4" wood supports spaced 24" o.c. using wood screws spaced 6" o.c. at perimeters and intermediate supports. System Type A: Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: One ply of Tamko Glass -Base, Vapor -Chan or Base-N-Ply fastened to the deck as described below: Fastening: (Option #1) Attach anchor sheet using 11 ga. annular ring shank nails and 1-5/8" diameter tin caps spaced 9" o.c. in a 4" lap and 9" o.c. in two staggered rows in the center of the sheet. (-52.5 psf, See General Limitation #7.) (Option #2) Attach anchor sheet using #12 or #14 Dekfast Fasteners with Hex Plates, SFS #12 or HD Insulfixx S, or Buildex Accutrac Fasteners and 3" Square Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. (-60 psf, See General Limitation #7.) One or more layers of any of the following insulations: Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe ACFoam II Minimum 1.2" thick N/A N/A U1traGard Gold Minimum 1.3" thick N/A N/A ENRGY-2, ENRGY-3, PSI-25 Minimum 1.4" thick N/A N/A Top or Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe ConPerl, EnergyGuard Perlite, Fesco Board, Retro-Fit, high Density Wood Fiberboard, Structodek FS Minimum W' thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. NOA No.: 07-0111.03 o Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 6 of 19 Base Sheet: (Optional) One ply of Glass -Base, Base-N-Ply, Versa -Base, Versa -Smooth, Awaplan VersaFlex, or Vapor -Chan adhered to the substrate with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Ply Sheet: One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan VersaFlex, Awaplan Versa -smooth, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400' F at the point of contact and at a rate of 20-40 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 4001b./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60'lb./sq.. 2. Tam -Pro FR Aluminum Coating applied at 1Y2 gal./sq., or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: See Anchor Sheet Fastening Options above. NOA No.: 07-0111.03 v Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 7 of 19 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type B(1): Base layer of insulation mechanically fastened; optional top layer adhered with approved asphalt. All General and System Limitations apply. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe ACFoam II, White Line Minimum LT' thick 1, 3,5 or 10 1:2 ft2 ACFoam H Minimum 1.4" thick 1, 3,5 or 10 1:4 ft2 ENRGY-2, ENRGY-3 Minimum 1.4" thick 1, 3,5 or 10 1:2 ft2 UltraGard Gold Minimum 1.3" thick 1, 3,5 or 10 1:2 W ACFoam Composite Minimum 1.5" thick 1, 3,5 or 10 1:4 ft2 ConPerl, EnergyGuard Perlite, Fesco Board, Armor Board Regular, Esgard, Wood Fiberboard, EnergyGuard Fiberboard, Huebert Fiberboard, Kop-R Wood Fiber, Structodek Minimum 1" thick 1, 3,5 or 10 1:2 ft2 Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). Top Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/fe ConPerl, EnergyGuard Perlite, Fesco Board, Retrofit Minimum 1/2" thick N/A N/A ACFoam Composite Minimum 1.5" thick N/A N/A Note: Apply optional top layer of insulation shall be adhered with approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 W'. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as the base layer shall only be used as the base layer with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side face down. Base Sheet: (Optional) One ply of Glass -Base, Base-N-Ply, Versa -Base, Versa -Smooth, Awaplan VersaFlex, or Vapor -Chan adhered to the substrate with a full mopping of approved asphalt applied within the EVT range and at a rate of 20401bs./sq. NOA No.: 07-0111.03 C. { Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 8 of 19 Ply Sheet: One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan VersaFlex, Awaplan Versa -Smooth, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400' F at the point of contact and at a rate of 20-40 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Tam -Pro FR Aluminum Coating applied at lV2 gal./sq. or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: -45 psf; (See General Limitation #9.) NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 9 of 19 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. Plywood shall be attached to 2" x 4" wood supports spaced 24" o.c. using wood screws spaced 6" o.c. at perimeters and intermediate supports. System Type B(2): Base layer of insulation mechanically fastened; top layer adhered with approved asphalt. All General and System Limitations apply. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam II, ENRGY-2, ENRGY-3, PSI-25 Minimum 1.5" thick 5 or 8 1:1.33 ftz Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for -fastening details). Top Insulation Layer (Optional) Insulation Fasteners Fastener (Table 3) Density/ftz High Density Wood Fiberboard Minimum'h" thick N/A Note: Apply optional top layer of insulation shall be adhered with approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ftz. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as the base layer shall only be used as the base layer with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side face down. Base Sheet: (Optional) One ply of Glass -Base, Base-N-Ply, Versa -Base, Versa -Smooth, Awaplan VersaFlex, or Vapor -Chan adhered to the substrate with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. Ply Sheet: One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan VersaFlex, Awaplan Versa -Smooth, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400` F at the point of contact and at a rate of 20-40 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. ' NOA No.: 07-0111.03 .AL L Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 10 of 19 Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 400 lb./sq. gravel or 3001b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Tam -Pro FR Aluminum Coating applied at 11/2 gal./sq., or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: -60 psf (See General Limitation #7.) NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 11 of 19 v Deck Type 1I: Wood, Insulated Deck Description: 19/32° or greater plywood or wood plank System Type C: All layers of insulation simultaneously mechanically fastened. All General and System Limitations apply. One or more layers of any of the following insulations: Base Insulation Layer ACFoam II, White Line Minimum 1.2" thick UltraGard Gold Minimum 1.3" thick ENRGY-2, ENRGY-3, PSI-25 Minimum 1.4" thick Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A N/A N/A N/A N/A Note: All layers shall be simultaneously attached; see top layer below for fasteners and density. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ConPerl, EnergyGuard Perlite, Fesco Board, Armor Board Regular, Esgard, Fiberboard, EnergyGuard Fiberboard, Huebert Fiberboard, Kop-R Wood Fiber Minimum 1" thick 1, 3,5 or 10 1:2 ft2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: (Optional) One ply of Glass -Base, Base-N-Ply, Versa -Base, Versa -Smooth, Awaplan VersaFlex, or Vapor -Chan adhered to the substrate with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. Ply Sheet: One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan VersaFlex, Awaplan Versa -Smooth, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400' F at the point of contact and at a rate of 2040 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 12 of 19 Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Tam -Pro FR Aluminum Coating applied at 1'/2 gal./sq., or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: -45 psf;(See General Limitation #9.) NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 13 of 19 Deck Type 1I: Wood, Insulated Deck Description: Minimum 15/32" or greater plywood or wood plank. Plywood shall be attached to 2" x 4" wood supports spaced 24" o.c. using wood screws spaced 6" o.c. at perimeters and intermediate supports. System Type D: Base sheet attached over insulation. All General and System Limitations apply. One or more layers of any of the following insulations adhered to deck: Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe ACFoam II, White Line Minimum 1.2" thick N/A N/A UltraGard Gold Minimum 1.3" thick N/A N/A ENRGY-2, ENRGY-3, PSI.25 Minimum 1.4" thick N/A N/A CouPerl, EnergyGuard Perlite, Fesco Board Minimum 3/4"" thick N/A N/A Armor Board Regular, Esgard, Fiberboard, EnergyGuard Fiberboard, Huebert Fiberboard, Kop- R Wood Fiber, Structodek Minimum'/2"" thick N/A N/A Note: Top layer_ shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: One ply of Tamko Glass -Base, Versa -Base, Awaflex, Versa -Flex, Vapor -Chan or Base-N-Ply fastened to the deck as described below: Fastening: Attach anchor sheet using #12 or #14 Dekfast Fasteners with Hex Plates or SFS #12 HD Insulfixx S or Buildex Accutrac Fasteners and 3" Square Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. Ply Sheet: (Optional) One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 14 of 19 Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400' F at the point of contact and at a rate of 20-40 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 4001b./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Tam -Pro FR Aluminum Coating applied at 1Y2 gal./sq., or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: -60 psf; (See General Limitation #7.) NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 15 of 19 Deck Type 1: Wood, Non -insulated Deck Description: Minimum 15/32" or greater plywood or wood plank. Plywood shall be attached to 2" x 4" wood supports spaced 24" o.c. using wood screws spaced 6" o.c. at perimeters and intermediate supports. System Type E: Base sheet mechanically fastened. All General and System Limitations apply. Anchor Sheet: One ply of Tamko Glass -Base, Vapor -Chan, Versa -Flex, Versa -Base, Versa - Smooth or Base-N-Ply fastened to the deck as described below: Fastening: (Option #1) Attach anchor sheet using 11 ga. annular ring shank nails and 1-5/8" diameter tin caps spaced 9" o.c. in a 4" lap and 9" o.c. in two staggered rows in the center of the sheet. (-52.5 psf, See General Limitation #7.) (Option #2) Attach anchor sheet using #12 or #14 Dekfast Fasteners with Hex Plates, SFS #12 or HD Insulfixx S, or Buildex Accutrac Fasteners and 3" Square Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two staggered rows in the center of the sheet. (-60.0 psf, See General Limitation #7.) Ply Sheet: (Optional) One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR,. Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400` F at the point of contact and at a rate of 20-40 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 400 lb./sq. gravel or 3001b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Tam -Pro FR Aluminum Coating applied at 1'/2 gal./sq., or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: See Base Sheet Fastening Options above NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 16 of 19 Deck Type 1: Wood, Non -insulated Deck Description: Minimum 15/32" or greater plywood or wood plank. Plywood shall be attached to 2" x 4" wood supports spaced 24" o.c. using wood screws spaced 6" o.c. at perimeters and intermediate supports. System Type E(2): Base sheet mechanically fastened. All General and System Limitations apply. Anchor Sheet: One ply of Tamko Glass -Base, Vapor -Chan, Versa -Flex, Versa -Base, Versa - Smooth or Base-N-Ply fastened to the deck as described below: Fastening: (Option #1) One ply of Red Rosin sheet loose laid over deck. Followed by anchor sheet attached using Simplex Mega Cap Nails spaced 9" o.c. in a 4" lap and 9" o.c. in two staggered rows in the center of the sheet. (-45 psf, See General Limitation #7.) (Option #2) Attach anchor sheet using Simplex Mega Cap Nails spaced 9" o.c. in a 4" lap and 9" o.c. in two staggered rows in the center of the sheet. ( —60 psf, See General Limitation #7.) Ply Sheet: (Optional) One or more plies of Tam -Glass Premium, Tam -Ply IV, Glass Base, Base-N-Ply, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Base adhered with a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Membrane: Awaplan Premium, Awaplan Premium FR, Awaplan 170, Awaflex, Awaflex FR„ Awaplan 170 FR, Awaplan Versa -Smooth, Awaplan VersaFlex, or Versa -Cap FR adhered with a full mopping of approved asphalt applied at 400' F at the point of contact and at a rate of 20-40 lbs./sq.; or Awaplan Heat Welding or Versa -Smooth adhered by torch. Surfacing: Optional to mineral surfaced Membranes. Required for smooth surfaced membranes: 1. 4001b./sq. gravel or 3001b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq.. 2. Tam -Pro FR Aluminum Coating applied at 1'/2 gal./sq. or Tam -Pro 846 Fibered Emulsion Coating at 3 gal./sq. Maximum Design Pressure: See Base Sheet Fastening Options above NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 17 of 19 Membrane Type: SBS Deck Type 1: Wood, Non -insulated Deck Description: 19/32' or greater plywood or wood plank System Type: Tile Underlayment, Base Sheet mechanically attached. All General and System Limitations shall apply. Anchor sheet: Tamko No. 30 UL, Type 43 Coated Base, Base-N-Ply®, Vapor-ChanTM, or Versa- BaseTM base sheet applied with a minimum 2" side lap and a minimum 6"end lap. Base sheet may be applied at a right angle (900) to the slope of the deck with approved annular ring shank nails and tin caps at a fastener spacing of 6" o.c. at the 2" side lap, and two 12" o.c. staggered rows along the center of the sheet. Ply Sheet: (Optional) One or more plies Tam -Ply WTM or Tam -Glass Premium"M sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Cap Sheet: One ply Awaplan PremiumTM, Awaplan 170TM, Awaflex, Tamko ASTM Slate Surface or Tamko ASTM Tile Underlayment. Cap sheet may be applied at a right angle (900) to the slope of the deck* adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20401bs./sq. Cap sheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. *Cap Sheet may also be installed parallel to the slope of the roof (i.e. strapping). If membrane or cap sheet is strapped, then anchor sheet and ply sheet must also be strapped. Maximum Design Pressure: Refer to Tile Manufacturer's NOA. Maximum Slope: Must Comply with Roofing Application Standard RAS 118, RAS 119, RAS 120 and Applicable Building Code. NOA No.: 07-0111.03 r Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 18 of 19 WOOD DECK SYSTEM LIMITATIONS: 1. A. slip -sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8 ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bs./sq. Note: Spot attached systems shall be limited. to a maximum design pressure'of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, inetal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 913-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 07-0111.03 Expiration Date: 05/23/12 Approval Date: 05/10/07 Page 19 of 19 M I A M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Entegra Sales, Inc. 819 S. Federal Highway Suite 300 Stuart, FL. 34994 MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Bella "High S" Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and folli the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, thei be done in its entirety. -- -' INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 7. The submitted documentation was reviewed by Alex igera. NOA No.: 06-0324.01 Expiration Date: 07/13/11 - �Zos Approval Date: 07/13/06 Page 1 of 7 r ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: 07320 Roofing Tiles Material: Concrete Deck Tvne• Wood I. SCOPE This approves a new roofing system using Entegra Bella "High S" concrete roof file as manufactured by Entegra Sales, Inc. in Okeechobee, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Descriution Bella "High S" L=16'/z" TAS 112 Low profile, interlocking, extruded concrete W =13" roof tile equipped with two nail holes and Thickness ='h" double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Trim Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for use at w = varies hips, rakes, ridges and valley terminations. varying thickness 2.1 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date IBA Consultants, Inc. 2421-94 ASTM C 1167 June 2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & 102(A) Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail -On) Redland Technologies P09647-01 Wind Tunnel Testing Aug. 1994 TAS 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Sept. 1993 Testing of screw vs. smooth shank nails The Center for Applied 94-083 Static Uplift Testing April 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) NOA No.: 06-0324.01 Y Expiration Date: 07/13/11 Approval Date: 07/13/06 Page 2 of 7 C� I . The Center for Applied 25-7094-(3, 6 & 9) Static Uplift Testing Oct. 1994 Engineering, Inc. TAS 102 The Center for Applied 25-7120-(1 & 2) Static Uplift Testing Nov. 1994 Engineering, Inc. TAS 102 The Center for Applied 25-7183-(3 & 4) Static Uplift Testing Feb. 1995 Engineering, Inc. TAS 102 The Center for Applied 25-7214-(3, 4, &7) Static Uplift Testing March, 1995 Engineering, Inc. TAS 102 The Center for Applied 25-7804-4 Static Uplift Testing Sep. 1996 Engineering, Inc. TAS 102 Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services TAS 101 Celotex Corporation 520191-2-1 Static Uplift Testing March 1999 Testing Services TAS 101 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 3. MUTATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set file applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. a . NOA No.: 06-0324.01 { Expiration Date: 07/13/11 Approval Date: 07/13/06 Page 3 of 7 1 4. INSTALLATION 4.1 Entegra Sales, Inc.'s Bella "High S" concrete roof tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length-1(ft) Width-w (ft) Bella "High S" Tile 10.5 1.375 1.08 Table 2: Aerodynamic Multipliers - A ft Tile Profile A (ft.) Batten Application A (ft ) Direct Deck Application Bella "High S" Tile 0.349 0.378 Table 3: Restoring Moments due to Gravi - M ft-Ib Tile Profile 3':12" 4":12" 5":12" 6":12" Greater than 7"•12" Bella "High S" Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck N/A 5.65 N/A 5.54 1 N/A 5.41 1 N/A 5.25 N/A 5.09 Table 4: Attachment Resistance Expressed as a Moment;- Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min.19/32" plywood) Battens Bella "High S" Tile 2-10d Ring Shank Nails 28.6 41.2 N/A 1-10d Smooth or Screw Shank Nail 5.1 6.8 N/A 2-10d Smooth or Screw Shank Nails 6.9 9.2 WA 1 #8 Screw 20.7 20.7 N/A 2 #8 Screw 43.2 43.2 NIA 1-10d Smooth or Screw Shank Nail Field Clip) 23.1 23.1 NIA 1-10d Smooth or Screw Shank Nail Eave Clip) 29.3 29.3 N/A 2-10d Smooth or Screw Shank Nails Field Clip) 27.6 27.6 NIA 2-10d Smooth or Screw Shank Nails Eave Cli 38.1 38.1 N/A 2-10d Ring Shank Nails 33.1 1 48.1 N/A 1. Installation with a 3" the headiap and fasterners are located a min. of 2f/2" from head of tile. 0 NOA No.: 06-0324.01 Expiration Date: 07/13/11 Approval Date: 07/13/06 Page 4 of 7 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bella "High S" Tile Adhesive 29.3 1 See manufactures component approval for installation requirements. LFlexible Products Company TileBond Average weight per patty 10.7 grams. Polyfoarn Product, Inc. Average weight per patty 8 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bella "High S° Tile Polyfoam Pol ProTM 66.5 Polyfoam Pol ProTM 38.74 3 Large patty placement of 63 rams of PolyProTm. 4 Medium patty placement of 24 rams of PoI ProTm. Table 5B: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Bella "High S" Tile Mortar Set 24.5 5 Tile-Tite Roof Tile Mortar. P NOA No.: 06.0324.01 _ Expiration Date: 07/13/11 Approval Date: 07/13/06 Page 5 of 7 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen in detail below, or following statement: "Miami -Dade County Product Control Approved". OR s;�z� E N T E 0 R R Entegra Sales Bella "High S" Concrete Tile Label (Located underneath Tile) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance.- 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 06-0324.01 Expiration Date: 07/13/11 Approval Date: 07/13/06 Page 6 of 7 A PROFILE DRAWING END OF THIS ACCEPTANCE NOA No.: 06-0324.01 Expiration Date: 07/13/11 Approval Date: 07/13/06 Page 7 of 7 M i A M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam .Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAM1, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyprog AH160 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.0 1 -0521.02 and consists of pages 1 through 7 The submitted documentation was reviewed by J rge L. Acebo. NOA No.: 06-0201.02 Expiration Date: 05/10/11__ - _{ cMY Approval Date: 0411310E 1�� - Page 1 of I - - ROOFING ASSEMBLY APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AH 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications Polypro@ AH160 N/A TAS 101 Two component polyurethane foam adhesive Foampro® RTF1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40' F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. ' NOA No.: 06-0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 2 of 7 A EVIDENCE SUBMITTED: • Test Agency Test Identifier _Test NametReport Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-01 l ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109 2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer -to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AH 160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. iF W F= i2: MS n;.--. NOANo.: 06-0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 NW Page 3 of 7 INSTALLATION: I. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro(g) AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and Iicensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Single Paddy Two Paddy Weight Detail Weight Min. per paddy Min. (gams) (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece #1 17/side on cap and N/A Barrel) 34/pan Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 g LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 06-0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY IN through pbstic cement paddy( ) Umkrlayment l � . FaaeCause . Fascla Eavecotwonty: EmCfesae KeepadhesWappmx 4h►uphwnweepholas NO through plastic cement td 10 in. 2n o EareCourse Fsda Weak Fare course only: Enavie, dosare KeepadhaskeapproL Ch. upfiomweephotes 1) Fbw enough adhesNe to KNM 17 to 23 OPitOnat antra for square iuehes at cwrtadwNh the pan N� s pfth aPPlicatlem; Nag through plastic cement 2) rum cavern upside dorm. Place adhesire 112 la 7o 1 It From outside edge of cover Bk Then i sta0 the tNe. o Undedaymed 0 o ,15 Rom p portion of / SheasheathingCQVL,rtik. Ahutto second course of pa Pan wverh7esVcodof PoadanpMortar flush at eave Gne.' on longihdw edgesoftle taveelasure Weeptale Facia (mortarshoxm) NOA No.: 06-0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 5 of 7 a D . ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Hail through plastic cement pa* (Beffmffillile) Nail through plastic cement Pa" (Berl" Too) Undedayment U ndedayment 1 =_ 1 7 in. 2 In. Tin. q 2 In. Eave Coame NOA No.: 06-0201.02 Expiration Date: 05110111 nz Approval Date: 04/13/06 wPage 6 of 7 J � I s Nail through plastic cement / O ADHESIVE PLACEMENT DETAIL 3 . DOUBLE PATTY Paddy Hart through plastic (between file) Underlaymerrt (under file) � �N� D f 1Din. Single Pady under talex3in. Si Ingle paddy on 2In. 4 in. under. ° Iayment ° rave course Single paddy to X 7 in medium on top of file shl paddy eave Fas' cia course only rNail through plastic cement \ /I- 1 �in.x 3 in. 4 Single paddy on underlayment 2 Single paddy on top of tile \' in.x 3 in. Single 4 in. 2 in. paddy on under- layment Single paddy on top of tiie Save Course paddy file Single paddy between tiie r, Eave Closure 7 in. medium eddy eave course only END OF THIS ACCEPTANCE -�acgi 9�L;Fr`�o Single paddy under file Single paddy between tile 2 in. x 7 in. medium size paddy save �ourseonly /� Fascia Weephole Eave closure . Ddp edge NOA No.: 06-0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 7 of 7