HomeMy WebLinkAboutSUBMITTED PAPERSOI���JSI;ONLY: r / - - • -- - J
DATE FILED: " 7`' �, .
RECEIPT NO.: PERMIT NUMBER: C%�'v�'
oc���Qd l� C�Y1 S
ALL INFO
OR10P
MUST BE COMPLETE &FILLED IN TO BE ACCEPTED Lj�JT�4-
St. Lucie County Building and Zoning
2300 Virginia Avenue
Ft. Pierce, FL 34982-5652
-462-1553
STORM REPAIR PEY214IIT
FOR ALUMINUM
�V
CARPORT STRUCTURES [,!�
PROJECT INFORMATION
1. LOCATION/SITE`,A�DDRESS.S: 10105 0- jQ!5
2. S/D NAME: C�1D�(�Y1 t'c-'ryk- SITE 1PLAN NAME:
3. PROPERTY TAX ID #: %i:3 n :2) - % (1 - n o,7r-; - %-rA
4. LEGAL DESCRIPTION (attach extra sheets if necessary):
5. PLAT J�- 6. PAGE t�L/r�}� 7. BLOCK 8. LOT I
BOOK I" NO. 1 V NO. NO. I V
6. PARCEL SIZE: ACRES/SQ FT. U 0 LOT DIMENSIONS 10 aZ 1Y (`464 • LQ1 y 1-3b.9 2 }C
`0 17 -75", �o X 137• -7 -7
7. DESCRIPTION OF CONSTRUCTION PROJECT OR WORK ACTIVITY: -0" ,t~: '(1 ?rt � tail
-p
i l' V (76kl -V •S //, . rl)nj' 1 T-=.Y. )r, i' i /.4 t0 '4Y41/1 Y -)-
2 copies of color photos will be required for of all proposed repair work as indicated. The photos
must include the address number of the home for inspection verification.
8. I, the contractor / owner have verified that the existing concrete slab is a minimum of 4" thick
and is in adequate condition to withstand the uplift and weight of the aluminum structure and
said structure will not exceed the f o rint of the carport that was in existence prior to removal by
the storms.
VdSignature .
FOUNDATION
)d SLAB ON GRADE [ ] RAISED SLAB W/FOOTER [ ] RAISED WOOD DECK ON FOOTING
9. Sq. Ft./CONSTRUCTION: 10. VALUE OF CONSTRUCTION: $ dG a
The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated
value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a
RECORDED Notice of Commencement must be submitted with this application.
IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification
it will be voided and returned to you by mail.
cY rr-riy F N Al1 05
orm o.• . /
//)(2/ . S:o .r.�t.� �P..! t z3 C�S,00 �4Vw,,•oo
OWNER INFORMATION
NAME:
ADDRESS:
CITY
�J
STATE: Zip -
PHONE (DAYTIME):(_ tit email:
IF THE FEE SIMPLE TITLEHOLDER (PROPERTY_ OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE
FILL IN NAME AND ADDRESS BELOW.
FEE SIMPLE TITLEHOLDER:
ADDRESS: L v
CITY: 1 STATE: ZIP
PHONE (DAYTIME): 07 7,1
CONTRACTOR INFORMATIONEn4dA��---ST.ST. of FL REG./CERT #: N.✓yTKLUCIE COUNTY CERT #:
BUSINESS NAME: _
QUALIFIERS NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
STATE:
FAX NO.
ZIP
email:
OWNER BUILDER / CONTRACTOR AFFIDAVIT: I certify that all the foregoing information is accurate
and that all work will be done in compliance with all applicable laws regulating construction and zoning.
I attest to the fact that a structure was located in the exact location where I plan to reconstruct due to damages caused by the storms. I
will. -not build any structure larger than what was in place prior to the storms. I will meet all setbacks that the County requires for the
community. I understand ny violation my cause me to remove or relocate any structure that is in violation of the setback
hav
requirements.
7a-c K,
OWNER BUILDE„* N, CONTRACTOR SIGNATURE
......,g,
STATE OF FLO STATE OF FLORIDA
COUNTY OF COUNTY OF
The foregoing instrument w acknowled ed
before me this Yday of�2 by
a x o
z R, N
'
L , who is personally
-a o i
own to me r who has produced
z
%?, as identification.
The foregoing instrument was
before me this _ day of
known to me or who
Signature of
_, 20_, by
is personally
identification.
Type or Print name of Notary / TyZormt Name of Notary
Commission No. - (Seal) Cosion No. (Seal)
NOTE: IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, IfiF OWNER MUST PERSONALLY APPEAR TO SIGN THIS
APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, OR THE OWNER BUILDER AFFIDAVIT MUST BE SIGNED
AND NOTORIZED WHEN SUBMITTED
The owner, owner builder, or contractor accepts FULL RESPONSIBILITY for the repair as declared in this application. St Lucie
County Building Department or other departments will not be held responsible as this permit is only intended to be constructed in
accordance with the attached specifications. Any deviations or additions to this repair will constitute a violation of the FBC and the
owner and/or contractor will be cited and prosecuted to the fullest extent that the law allows.
I have read and fully understand my responsibilities
O e uilder / Contracto Date
12" WIDE x 3" RISER INTERLOCKING ROOF PANEL r
o
0
ri
-- �_ 12.00- l
COMPOSITE ROOF PANEL (INDUSTRY STANDARD
ALUMINUM $KISKINE.P.S..S. CO CORE
J=
W I-- SIDE CONNECTIONS VARY
Z Lij
0.
0. o (DONOT AFFECT SPANS)
48.00-
3" RISER PANS OR 48" COMPOSITE PANELS
(2)1/4" THRU BOLTS
�"Pq,X.060
3'' z 3'Sx .060
ALTERNATE CONNECTION:
(3) 88 SCREWS PER PAN WITH
1" MINIMUM EMBEDMENT INTO
FASCIA THROUGH PAN BOXED
END
EXISTING TRUSS OR RAFTER
010 x 1-12' S.M.S- (2) PER
RAFTER OR TRUSS TAIL
p10 x 314' S.M.S. @ 12- O.C.
EXISTING FASCIA
3" RISER PANS OR 448" COMPOSITE PANELS
OVERALL PROJECTION
ROOF ANCHORING DETAILS
SEALANT
?a
a p ROOF PANEL
EDGE
2"x6
EDGE BEAM ,
2"x 6"x.050 SMB
98 x 112- S.M.S.13) PER PAN
(BOTTOM) AND 11) @ RISER
(TOP) CAULK ALL EXPOSED
SCREW HEADS
ROOF PANEL TO FASCIA DETAIL
SCALE: 3- = 1'-0'
f— SEALANT
FOR MASONRY USE
114' x 1.114- MASONRY
j
ANCHOR OR EQUAL @ 24' O.C.
FOR WOOD
WOODSCREWS
S.M.S. OR WOOD SCREWSS@/
2' O.CC .
EXISTING HOST STRUCTURE:
/
WOOD FRAME. MASONRY OR
OTHER CONSTRUCTION
/
Z _
a o
INTERNAL EXTRUDED ROOF PANEL TO WALL DETAIL
ALUMINUM BASE OR BREAK FORMED
' / U-CLIP WITH WALL EQUAL TO OR GREATER
ITHAN WALL POST.
—� (2)1/4"THRU BOLTS
CONCRETE
WHEN FASTENING PANELS
OR PANS TO WOOD PLATES
SCREWS SHALL HAVE A
MINIMUM EMBEDMENT OF 1-
CAULK ALL EXPOSED SCREW
HEADS 6 WASHERS
FOR COMPOSITE ROOFS
n 10 x (I - 12-) S.M.S. Wl
1-114-O FENDER WASHERS
@ Ii- Q.C. (LENGTH =
PANEL THICKNESS— l')
@ ROOF BEARING ELEMENT
(SHOWN) AND 24- O.G. @
NON -BEARING ELEMENT (SIDE
WALLS)
4 — 3/8" concrete anchors with min. of
2 3/8" imbedded into concrete
FOR PAID ROOFS
13) EACH c8 .. 112- LONG S M,S
PER 12- PANEL IN/ 314-
ALUnmMVM PAID LNA$liLR
BEAM
K .050 SMB
ROOF PANEL
08 x 112- S.M.S. (3) PER PAN
(BOTTOM) AND (1) @ RISER
(TOP.) CAULK ALL EXPOSED
SCREW HEADS
HOST STRUCTURE MASONRY
OR FRAMED WALL
PRIMARY BEAM
ANGLE OR RECEIVING
CHANNEL
S
ROOF PANEL TO BEAM FASTENING DETAIL BEAM TO WALL CONNECT)OI
3" RISER PANS OR 48" MITE PANELS
L
M
SMB
;0
EDGE BEAM
2" x 6"x.050 SMB
3" z 3'$x 060
OVER ALL PROJECTION
3" RISER PANS OR 48" COMPOSITE PANELS
MAXIMUM SPANS BETWEEN UPRIGHTS
-12' CARPORTS =12 ' 8 "
-14' CARPORTS =12 ' 1 "
(SPANS WILL VARY BUT CANNOT EXCEED ABOVE SPANS)
3" RISER PANS OR 48" COMPOSITE PANELS
MAXIMUM SPANS BETWEEN UPRIGHTS
-12' CARPORTS =12' 8 "
-14' CARPORTS =12 ' 1 "
(SPANS WILL VARY BUT CANNOT EXCEED ABOVE. SPANS)
EDGE BEAM. -
2" x 6" x .050 SMB
BEAM TO WALL CONNECTION:
(2) 2- . 2'. 0 OW"
EXTERNALLY MOUNTED
Note: 2 copies of these specifications must be signed
ANGLES ATTACHED TO+OOD
and submitted with the permit application.
P pp
FRAM WALL W/ MIN 12)3/8-.
^Q r
Permit # ]Ur
T LAG SCREWS PER SIDE OR
TO CONCRETE (2) .
2n/<- ANCHORS OOR MASAS ONRY -.
WALL ADD (1) ANCHOR PER
SIDE FOR EACH INCH OF BEAM -
DEPTH LARGER THAN 3-
ALTERNATE CONNECTION:
(1) 1.314P , 1.3/4- ■ 1.31t' . 1/8'
INTERNAL U-CHANNEL
ATTACHED TO WOOD FRAME
WALL W/ MIN (3) 3/8' , 2- LAG
SCREWS OR TO CONCRETE
OR MASONRY WALL W/13) ua-
. 2- I /a- ANCHORS OR ADO 11)
ANCHOR PER SIDE FOR EACH
INCH OF BEAM DEPTH
LARGER THAN 3"
I)L
Carport Replacement Specifications
Designed for Single Carports Only
For all areas except Hutchinson Island and
Indian River Drive. Any carport that exceed
the spans listed below can not use this design
sheet and must have specific engineering.
3" X 12" Carport Pans cannot exceed 12'span
3" X 45" Comp. Panels cannot exceed 14'
Joy Iso
MH Owner's name
Acrdress
A ro
City State Zip
Contractor
Address
City State Zip
Carport Size: Length o:?/ JI Width le-2
Roof Type: (must indicate)
❑ 3" X 12" pans Ja 3" X 48" Insulated
P .024 ❑ .032 R
Any additional structures that are added that were not
in place previous to the storms will require full ap-
plication, engineering, and review and must meet ti)e
current building code that may include 4`s wall con-
struction.
Carport structures that include within the roof coverage
area the following; sheds, screen rooms, sun rooms,
glass rooms, raised structures, may not use this
sheet and will require complete engineering as if
new construction.
The u of these specification is approved by:
0"3
Dennis M. Grim, CBO Date
St. Lucie County Building Official
I have read and fully understand my responsibility as a
Contractor or Owner builder, that the carport will
meet these specifications and will be inspected by
the Countv after co Retion.
�0
.r-
Date
Not valid unless stamped and dated by County I I sig( aYe of Contractor
Code Compliance Division BUILDING PERMIT
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
hftp://stlucieco.gov/ce
Issued: 04/10/2008 Conf A 770
Job Location: 10105 GASLIGHT CT
Permit Type: MA/RV Addition Existing Concrete
Job Description:
Permit #: SLC- 0804-0043
City: FORT PIERCE
Page 1
RECONSTRUCTION OF A CARPORT [ 12' X 21' ) AND COMPOSITE ROOF SYSTEM OVER EXISTING FLORIDA ROOM
W 4TH WALL TRAC BEAM AND COLUMNS [ 1 V X 21' )
S/D Lot: Block: Parcel: 2303-211-0025-000/5
Applicant JOAN AND NELSON PAYNE (772) 489-0721
10105 GASLIGHT FORT PIERCE, FL 34945
Property Owner PERSHING MOBILE HOMES ( ) -
901 NW 31 STAVE POMPANO BEACH, FL 33069
Setbacks Left: 15.00 Right: 15.00 Front:30.00 Rear: 41.00 Zoning: RMH-5
Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00
Minimum Floor Elevation: Flood Map: 175F Flood Zone: X Elev:
Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code
including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all
requirements of the 2004 Florida Building Code.
NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the
records of this County, and there may be additional permits required from other governmental entities such as water management districts, state
agencies, or federal agencies. s:553.79(10), F.S.
WARNING TO OWNER:- YOUR -FAILURE TO -RECORD A NOTICE -OF -COMMENCEMENT -MAY -RESULT IN YOUR PAYING -TWICE -FOR - - - - — -
BUILDING IMPROVEMENTS TO YOUR PROPERTY., IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S.
Christopher Lestrange
Building Official Date
For Automated Inspections, Call (772) 462-1261
For Questions, Call (772) 462-2172
St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and
become null and void if work authorized by such Building Permit is not commenced, having called for and
received a satisfactory inspection, within six (6) months from"the date of issuance of the permit, or if the work is
not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance
of the Building Permit.
Building
Code Compliance Division Receipt
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
hftp:/Istfucleco.gov/ce
Date:
10 April 2008
Job Address:
10105 GASLIGHT CT
Received By:
dimonb
Paid With:
CK
Paid By: JOAN B PAYNE
Sign:
Receipt #:
0000062077
'ermitNumber:
SLC- 0804-0043
Amount:
$155.00
�redit Card Number:
Check Number:
3358
St. Lucie County
Building & Zoning Department
2300 Virginia Avenue
Fort Pierce, Florida 34982
(772)462-1553
OWNER/BUILDER AFFIDAVIT DISCLOSURE STATEMENT
F.S. 489.103 (7) EXEMPTIONS .
State law requires construction to be done by licensed contractors. You have applied for a permit under an
exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even
though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You
may build or improve farm outbuildings, a one -family or two-family residence or a commercial building at a cost of
under $75,000.00. The building or residence must be for your own occupancy. It may not be built or substantially
improved for sale or lease. If you sell or lease a building you have built or substantially improved your self within
one year after the construction is complete, the law will presume that you built or substantially improved it for sale
or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or
to supervise people working on your building; it is your responsibility to make sure that people employed by you
have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the
responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done.
Any person working on your building who is not licensed must work under your direct supervision and must be
employed by you, which means that you must deduct `F.I.C.A. and withholding tax and provide workers'
compensation for that employee, all as prescribed by law. Your construction must comply with all applic laws��
ordinances, building codes, and zoning regulations. Initial'` - r
I understand that the building official and inspectors are not there to design or give advice on how tom t
the minimum code. Initial -
I understand that as an owner -builder that any contract disputes with sub -contractors and I must be handled
in a civil court with the advice of an attorney. This department will not mitigate any contract disputes.
Initial c
I understand that if I compensate any person or company for work performed they are requir7dto be
licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible and liabl r th
cost of the license. Initial r
I understand that if any person that is unlicensed and uninsured gets injured on my construction project -
they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and related medic
cost, which could include loss of.wages during recovery from their injury. Initial ��
To qualify for this exemption under this subsection, an owner must personally appear and sign th uilding
permit application and initial the above.
I hereby acknowledge that I have read and understand the -above disclosure statement and that I further
understand that any violation of the terms of the ownerlbuilder exemption shall be reported by the Building and
Zonmi Departmen o the Florida State Department of Professional Regulation.. Signed and acknowledged on this
I day of of 20 .
Owner/$u(�oer Signature
F
STATE OF FLORID
COUNTY OF (`
The fore oing instrument was acknowledged before me this day of MAI
by 0 19 Kt TQ Y AtC---_ who is personally known to me, or who has
produced as identification.
r
Signature of taryT e or Print Name of No
Title: NojgJRublic ommission Number °lN•,. AUDREY B. HU7Undenv6ters
r: ;r- COMMISSION
=> •.
EXPIRES: Marc
'p� fh`• Bonded Thru Notary Pu
u
Property Appraiser - St.Lucie C, --,ty, FL Page 1 of 1
Pershing Mobile Home Sales Inc Record: 1 of 3
Property Identification
Site Address: 10001 WANGLE RD
SecfTown/Range: 03 :35S :39E
Map ID: 23/03N
Zoning: CN
1
PROPERTY RECORD CARD
«Prey Next» Spec.Assmnt Taxes Exemptions Permits Home Print
�UGIE �
ParcellD: 2303-211-0025-000-5
Account #: 12845
Land Use: PRKG/MOBILE,_
City/Cnty: ST. LUCIE COUNTY
Ownership and Mailing
Legal Description
Owner:
Pershing Mobile Home Sales Inc
3 35 39 NW 1/4-LESS AVON MANOR -UNITS 1 AND 2 AND LESS W
Address:
901 NW 31st Ave
615.5FT LYG S OF AVON
MANOR -UNIT 1 AND LESS
Pompano Beach FL 33069-1100
More...
Sales Information
Assessment Final
Total Land and Building
Date Price
Code Deed Book/Page
2007 FV: 9973200
Land Value: 8280000 Acres: 99.02
3/31/1989 6730000
00 WD 0630 / 0131
Assessed: 9973200
Building Value: 1693200
6/1/1984 1150000
01 CV 0433 / 2528
Ag.Credit: 0
Finished Area: 13526 SgFt
6/1/1974 0
02 CV 0228 / 1382
Exempt: 0
Taxable: 9973200
Taxes: 188361.82
BUILDING INFORMATION
'No.. Im.aa.,e
Available
Exterior Features
View: -
RoofCover:
-
RoofStruct: -
ExtType: MHPK - MH Parks YearBlt:
1985
Frame: -
Grade: C - C
EffYrBlt:
1985
PrimeWall: -
StoryHght: 0010 - 1 Story
No.Units:
SecWall: -
Interior Features
BedRooms: 414
Electric:
-
PrmintWail: -
FullBath: 0
HeatType:
-
AvgHt/Fl:
1/213ath: 0
HeatFuel:
-
Prm.Flors: -
%A/C: 0
%Heated:
0
%Sprinkled: 0
Special Features and Yard Items
Land Information
Type Y/S Qty.
Units Qual. Cond.
YrBlt.
No. Land Use
Type Measure Depth
SWAV - RES POOL AVG Y 1
576 AV
AV
1985
1 2800-PRKG/MOBILE 112 -Site 414
PA01 - POOL DK-AVG Y 1
1444 AV
AV
1985
ASP1 - ASP1 HIGH Y 1
6000 AV
AV
1985
CNC1 - CONCRET HIGH Y 1
1375 AV
AV
1985
ASP1 - ASP1 HIGH Y 1
123000 AV
AV
1985
CURB - CEMENT CURB Y 1
150 AV
AV
1985
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
http://www.paslc.org/prc.asp?prclid=230321100250005 4/4/2008
Friday, Apr 04, 2008 08:38 AM
Code Compliance Division
2300 Virginia Avenue Alert Maintenance
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148 -
http://stiucieco.gov/ce
PJkQPERTyJNF0,RI0xqqN
Parcel # 2303-211-0025-000/5 Jurisdiction St. Lucie County
Permit # 0503-1983 Lists first permit on property. Reference only. Zoning Residential, Mobile Home - 5
Address 10105 GASLIGHT CT FORT PIERCE 34945
4 jActive Permitting
7.8.05 DOUBLE FEE CARPORT
07/08/2005
augustem
7.8.05 DOUBLE FEE CARPORT
07/08/2005
augustem
PERMIT AND ROOF OVER
PORCH(OLIVER SMITH) **
Field Trip W Carl B. 02/01/2008
revealed Carport and R/S over
fam.rm needs permits to current
codes * Jmc
1. You must enter a number in the severity column to show the information. If it's blank, there will be
no light to indicate that there is a message.
2. Please reference the permit # or permit type. When there is more than one permit, it's cifficult to
determine what the message is referencing.
13uild'ing
Code Compliance Division Receipt
2300 Virginia Avenue
Ft. Pierce, Fl- 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
hftp://stfucleco.gov/ce
Date:
04 April 2008
Job Address:
10105 GASLIGHT CT
Received By:
humphreya
Paid With:
CK
Paid By: JOAN PAYNE
jo
Sign:
Receipt #:
0000061934
ermit Number:
'SLC- 0804-0043
Amount:
$50.00
redit Card Number:
Check Number:
3354
) -� 6
FILE uupy
MIN. SETBACK REQ.
FRONT _1,6' I
SIDES
CNR SIDESAD
REAR 15 '1'
-711- iM ] Z:
I TECH.
f r-
Him
HAUE u1
Permit NO. Tax = 'L303 ~%�tl � 00;.S7
State or. F1 nri f1m, Counq•Of St. Lucie
THE UNDERSIGNED hereby gives notice that improvement. will be made to certain real properl. and in accordance With Chapter
713, Florida Statutes, the following information is provided in this Notice of Comrnencement.
Legal Description of prop", and street address, if available NW 1/4—Less vt� Manor Tni f s 1 2 �-
_ Less W 615.5 ft. lya E. of Avon Manor - Unit 1 & less anal —
10001 West Angle Road, Fort Pierce, FL 34945
General descriptiomof improvements
Owner- p rs n
a 9 45
u
f
• ' q �-- FG O�/.C>�J G,rIS :'."��lil/Sl-!/SS/O�t/
O. 43
= =_ LS o68 N —
,, n, y ZOO • ' S . � - � � _..
d7.
Co
. - 1 - � ,� 1��10 •�� ".• Y�: 6� �` W � 7�.2�?" 1%7S�r �Rr 27.SG' -
`
�= •moo - �'i ��� � 7� � �. �`�'� � �; Y�1� '�f.�:`� -�� � ��^",�„' � , :s oo '1`lg —_4�. , �6 .�• ` ..Aj
O
IV
Ch
to UN
ZI
��\�,,- / a,/ DICE � , • ` '\ � � .� o ��� �, ' fail ` `', ... `ya ��,�,,. ��,• � � ;v ��
��a , /Ci -� \\ r` ice' �.' �C31 ^•` r;' - °' 1 i -f r :..:�-� �: a � \n ° \ �'�
j� •
ROOF PANEL MIN.
FALL j PER FOOT
SEE PLAN
FOR SIZE
in
cu
x0
C`7 a
x
(h
FINISHED '
GRADE
ELEVATION C—C
FLASHING ONLY (DO NOT
STRUCTURALLY CONNECT
TO EXISTING STRUCTURE)
4th WALL CONSTRUCTION
(NO SUPPORT FROM
EXISTING STRUCTURE) �I
W Ill
I
(Y I
a-U
F- I
I cl) I
I
O~ 1
Z L3 I
x I
I
" ■
FLASHING ONLY (DO NOT
STRUCTURALLY CONNECT
TO EXISTING STRUCTURE)
1 4th WALL CONSTRUCTION
(NO SUPPORT FROM
I/ EXISTING STRUCTURE)
w
I
::D CY
I
I �W
I
I 0 H
I 2 l7
I =
I
I
I
I
I
I
I
I
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY Will ALL APPy4A066 999M
SEE PLAN
FOR SIZE
o V
(h Dom..
(h
ELEVATION B—B
ROOF PANEL MIN.
FALL j PER FOOT
0
I
2'
MIN,
FINISHED
GRADE
� • r-r rr
I�
3x3x0.125
POST
FINISHED
GRADE
KNEE
`BRACE
1 TYP.
NON-SUPPORT
HOST STRUCTURE
EXISTING MANUFACTURED HOME
4th WALL CONSTRUCTION
(NO SUPPORT FROM
EXISTING STRUCTURE)
P y
FLASHING ONLY (D❑ NOT
STRUCTURALLY CONNECT '
TO EXISTING STRUCTURE) I
I
DO KIM
& ASS❑0IATES, LLD
CONSULTING
STRUCTURAL
ENGINEERS
3300 Henderson Blvd., Suite 106
Tampa, FL 33609
Tel: (813) 8745900
Fax: (813) 8745959
• --
--
---------
---------
— — ---- ---- --
- - - 2x RAC
--------
-----
-� RevJDate
Des
20D
ISSUED
3x3x0,125
EA
3x3
0,125
I 3x3x0.125 Z
POST
POST
l POST
I
7'-0'
7,_
,
i
I I
I
I
I
I I 0
SCREEN ROOM
I
I � 0
I
3xO.024 (1-LB EPS)
COMPOSITE PANELS
I i
I EDGE OF
I CONCRETE 0
(ELITE-FL-7561)
EXISTING RAISED
CONCRETE SLAB
BY OTHERS
PLAN �a
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
ROOF BEYOND NOT
SHOWN FOR CLARITY NEW COMPOSITE
PANELS
ST, LUCIE COUNTY
BUILDINGDIVISI
RM
FOR COre17P CE
REVIEWED BY
DATE °a
PLANS D P RMIT
MUST BE PT ON JOB OR
NO INSPE ON WILL BE MADE
0
I
2' MIN.
FINISHED
GRADE
21'-O'±
UNDISTURBED
ELEVATION A —A S❑IL OR COMPACTED
CRUSHED LIMEROCK
(90% PROCTOR)
U
J
J
U
a)
LU
co
O
U
LO
U M
CO)
Z
ate)
L
ISa
_j
.&
~
N ca L)
W(D m
U
mLna
W
J
W
N
U
0
aCti
DRAWN BY:
JMS
CHECKED BY:
DYK
SCALE:
AS SHOWN
DATE:
3/24108
E.
FIKIM
UMBER 49497
V&
DSSOCIATES, LLC
CA# 26887
.3300 HENDERSON BLVD.,
SUITE 106
Tampa, FL 33684
Drawing No. - 080324
SHEET 1OF2
ANk
IA
s. 1
#14x4' S.M.S. W/ 1 '0 FENDER WASHER
AND NEOPRENE GASKET @ 12' O.C.
( (5) PER PANEL MINIMUM )
3' COMPOSITE
R00F PANEL SLOPE
O O O O O O O O O O O IL
0000000000 000000O0 0 0 0 C
0000000000 00000�00000 C
0
S.M.B. BEAM 0
(SEE PLAN FOR SIZE)
NOTCH POST TO ACCEPT BEAM
BEAM STITCHING SCREW T & B @
24' O.C. (SEE TABLE FOR SIZE)
SLOPE \
O O O O O
00 0 0 0 0 0 000000000000000
0000000000000n0
2Ys'x2' REC. CHANNEL
W/(2)-Y4'0 THRU-BOLT
W/ /4' WASHERS
(2)-%'O THRU-BOLT W/ 1}'0 WASHER NOTCH POST TO ACCEPT
BEAM STITCHING SCREW T & B @
(MIN.) 3x3x0.093 POST 24' D.C. (SEE TABLE FOR SIZE)
(SEE PLAN FDR SIZE)
COMPOSITE ROOF TO EDGE BEAM
CONNECTION DETAIL
S.M.H. BEAM
(SEE PLAN FOR SIZE)
2' WIDE X 6' LONG X Y- MIN.
THICK STRAP (6063-T6 ALLOY)
WITH .(2)-#12 X 3/4' S.M.S. &
BOLTS.
'0 THRU-BOLT
0 WASHER
POST TO
T BEAM
ALTERNATIVE' DETAIL
USING EDGE BEAM FASTENING
NOTCH KNEE BRACE TO ACCEPT I -------------------
BEAM FASTEN WITH (2) 8"0 THRU 4 I BEAM (SEE PLAN FOR SIZE)
BOLTS W/ 1 J"O WASHERS
L___----=--------J
(2>-%'O THRU-BOLT
W/ 1}'0 WASHER
(MIN.) 3x3X0.093 POST
(SEE PLAN FOR SIZE)
COMPOSITE ROOF PANEL TO
CENTER BEAM 814th WALL
BEAM CONNECTION
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT FIELD
CORREIIIONI
INSPECTORS i�1p►T
REQUIRED BY
MAY BE NECESSARY IN ORDER To
OPP
General Notes and Specifications: rlLt y
1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies Lfor 'im.e 'J
consideration.
2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318.
Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318.
If existing concrete slabs/footings are deemed satisfactory, it may be incorporated into new slab/footing by observing the
following procedure:
a) Clean and scabble all connecting edges.
b) Drill and epoxy embed #5 reinforcing placed @ 12" O.C. mid depth. The rebar should be embedded a min. of 7" (using Hilti HY
150 Epoxy or equal approved), leaving 24" exposed to be incorporated into new slab/footing.
3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary.
4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The
contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If
there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host
structure capacity.
5. Screen density shall be a maximum of 20 x 20 mesh.
6. Connections using screw bosses shall have minimum (4)-#10x2" per connection unless shown otherwise.
7. Screws that penetrate the water channel of the super gutter shall have ends clipped off for safety of cleaning the gutter and
the heads of screws through the gutter into the fascia shall be caulked.
8. Every panel of screen mesh shall be fastened securely in place with spline. Each panel shall be fastened at all sides,
independent of surrounding panels. This requirement shall include purlins and chair/kickplate rails. Screen mesh panels are not
required to be secured to rigid diagonal bracing members. Screen mesh is incidental to the structural integrity of the overall
structure.
9. Unless otherwise shown. screws shall have minimum edoe distance and center -to -center distances as shown in this table.
1-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws)
Screw
Nominal Screw Diameter
(In)
Minimum Edge Distance
Minimum Center to Center
Distance
#10
0.188
s/
''/2"
#12
0.219
3/ "
#14' (1/4")
0.250
'/2"
s/p'
10. Structure has been designed to meet the 2004 FBC with 2006 Supplement. Project is sited where the basic wind speed is 140 mph
(3-sec gust).1=0.77 for screen enclosures. Exposure B. Design wind pressures are from 2004 FBC. Pressures are based on wind
tunnel testing with main wind force resisting system coefficient, GCp, of +/-0.25 for screen roof and 0.7-1.25 for walls.
11. All concrete anchors shall be Simpson Strong -Tie Wedge All Anchors or Titian Screws or approved equal.
12. Designed in accordance to Aluminum Design Manual, LFRD.
13. All Aluminum members shall be 6063-T6 Alloy unless otherwise noted. Trac Beams shall be 6005-T5 Alloy.
14. Aluminum roof pans shall be of aluminum alloy 3105-H14 or 3105-H28. Composite panel skins shall be of aluminum alloy' 3105-H15
or 3105-H25.
R
KET F@N8,
3' COMPOSITE
AND NED RENE GA ELc.
I to
I
7
ROOF PANELS
of
1
I
I
°°°°
°°90°000O oo0
o
I
3x3x0.093 KNEE BRACE
°O0OOO O0O0
0000
0000
.
I o
1
/V
r%r%
W PANEL
/ CONNECT KNEE BRACE WITH .THICK_J
Y8"
WIDTH MAX.
I
/ PLATE, 6063—T6 ALLOY OR STRONGER,
(8) #140/4' S.M.S., (4) SCREWS
EACH LEG )
FASTEN WITH (8) #14X%4" S.M.S.
I
} C i
,/
S.M.B. BEAM
IXb9' BY 4' LONG ANGLE
I
I
/
(SEE PLAN FOR SIZE)
CTYP. EACH SIDE)
0
1
+*
BEAM STITCHING SCREW T & B @
NOTCH POST TO ACCEPT BEAM
I
24' D.C. (SEE TABLE FOR SIZE)
_
I
I
I
I
KNEE BRACE LENGTH
COLUMN/POST
I
I
I
(24" MIN.)
(SEE PLAN FOR SIZE)
COMPOSITE ROOF TO SIDE WALL HEADER
CONNECTION DETAIL
HORIZONTAL KNEE BRACE
CONNECTION DETAIL
POST COLUMN
toN* CEALEO FASTENERS OR ATTACHMENTS
'ARE THE RESON8181 TY OF THE
GONTRA�iO�OFRECORD
(2)-VO THRU BOLT V/1Y4'0 WASHER
3' BASE INSERT W/EARS
W/1W VERTICAL LEGS
X' THICK 6063-T6 ALLOY (TYP.)
(2)-#14x1%' CONCRETE
SCREWS, EACH LEG
(4)-Y4'0 HOT DIPPED GALVANIZED EXPANSION
ANCHORS W/ 2%- MIN. EMBEDMENT INTO CONCRETE.
�� • t •
TOP OF CONCRETE -
;
-
• 4.4 • ..
a' ..
w
13Fz'
MIN.
POST TO CONCRETE SLAB
2' MIN. EDGE
DISTANCE (TYP.)
CONNECTION DETAIL
DO KI M
& ASS0CIATES, LLD
CONSULTING
STRUCTURAL
ENGINEERS
3300 Henderson Blvd., Suite 106
Tampa,'FL 33609
Tel: (813) 874-5900
Fax: (813) 874-5959
0I mOa l ISSUED I
r.I
U
J
J
N
L
O
.
..
w
to
O
U
LO
It
_ rn
0 U
U)
(M
ca
Z
'=
O
1_
p
LLLL.
W
o .�
~
W 0
I—
N
0 a`)
Z
U
a1 to a
W
O
---1
W
to O O
U
p
LL r- LL
DRAWN BY:
JMS
CHECKED BY:
DYK
SCALE:
AS SHOWN
DATE:
3/24108
O M E.
F I �`'U�tM( ER 49497
DO KI 8 A SOCIATES, LLC
CA# 26887
3300 HENDERSON BLVD.,
SUITE 106
Tampa, FL 33684
Drawing No. - 080324
SHEET 2 OF 2