Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS_2
ST. LUCIE COUNTY - INFORMATION SHEET I/ u PERMIT # 0709-0291 PROJECT NAME/MODEL WILLIAMS— 3 STORY [,;A-tE OF ORIGINAL REVIEW 10/15/2007 REVIEWED BY LYNDIA GALBRAITH CONTRACTOR:_ GROZA BUILDERS,. INC. OFFICE: 336-7653 FAX: 336-2272 ITEM # AND DESCRIPTION OF RESPONSE ANSWERS TO PLAN REVIEW COMMENTS • REVISION 1.) SURVEY MISSING PROPOSED (PROPOGSED—FFE= 9'W GARAGE= 9'—SURVEY SHOWS FFE ' 1N NOTES # 4 2.) PLUMBING SUB AGREEMENT MISSING ATTACHED PLUMBING PERMIT ATTACHED FOR SUBMITTAL 3.) FT. PIERCE UTILITY ONLY SHOWS WATER, IS THERE A NO, SEWER PROVIDED BY ISLAND DUNES COUNTRY EPARATE AGREEMENT FOR CLUB WASTEWATER PLANT SEWER? 'c..) PERMIT NEEDS RETURNED TO ZONING FOR STORM WATER ATTACHED ATTACHED A COPY OF THE RECORDED PLAT PLAN I CHECK & TO SEE IF APPROVED GOT FROM ZONING COPY OF SITE PLAN IS IN. 5.) ENVIORNMENTAL DEPT. REQUIRES NEW VEGITATION ATTACHED ATTACHED IS A COMPLETED VEGITATION PERMIT PERMIT APPLICATION. DATE 10/31/07 ALL REQUESTED REVISION HAVE BEEN MADE w NATIONAL FLOOD INSURANCE PROGRAM ELEVATION CERTIFICATE AND INSTRUCTIONS ~ NATIONAL FLOOD INSURANCE PROGRAM ,e ELEVATION CERTIFICATE PAPERWORK REDUCTION ACT NOTICE Public reporting burden for the Elevation Certificate is estimated to average 3.5 hours per response. Burden means the time, effort, or financial resources expended by persons to generate, maintain, retain, disclose, or provide information to the Federal Emergency Management Agency (FEMA). You are not required to respond to the collection of information unless a valid OMB control number is displayed in the upper right corner of the form. You may send comments regarding the accuracy of the burden estimate and any suggestions for reducing the burden to: U.S. Department of Homeland Security, Federal Emergency Management Agency, Mitigation Division, 500 C Street SW, Washington DC 20472, Paperwork Reduction Project (1660-0008). NOTE: Do not send your completed form to this address. To obtain or retain benefits under the National Flood Insurance Program (NFIP), you must respond to this collection of information. PURPOSE OF THE ELEVATION CERTIFICATE The Elevation Certificate is an important administrative tool of the National Flood Insurance Program (NFIP). It is to be used to provide elevation information necessary to ensure compliance with community floodplain management ordinances, to determine the proper insurance premium rate, and to support a request for a Letter of Map Amendment (LOMA) or Letter of Map Revision based on fill (LOMR-F). " The Elevation Certificate is required in order to properly rate post -FIRM buildings, which are buildings constructed after publication of the Flood Insurance Rate Map (FIRM), located in flood insurance Zones Al-A30, AE, AH, A (with BFE), VE, VI-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, and AR/AO. The Elevation Certificate is not required for pre -FIRM buildings unless the building is being rated under the optional post -FIRM flood insurance rules. As part of the agreement for making flood insurance available in a community, the NFIP requires the community to adopt a floodplain management ordinance that specifies minimum requirements for reducing flood losses. One such requirement is for the community to obtain the elevation of the lowest floor (including basement) of all new and substantially improved buildings, and maintain a record of such information. The Elevation Certificate provides a way for a community to document compliance with the community's floodplain management ordinance. Use of this certificate does not provide a waiver of the flood insurance purchase requirement. Only a LOMA or LOMR-F from the Federal Emergency Management Agency (FEMA) can amend the FIRM and remove the Federal mandate for a lending institution to require the purchase of flood insurance. However, the lending institution has the option of requiring flood insurance even if a LOMA/LOMR-F has been issued by FEMA. The Elevation Certificate may be used to support a LOMA or LOMR-F request. Lowest floor and lowest adjacent grade elevations certified by a surveyor or engineer will be required if the certificate is used to support a LOMA or LOMR-F request. A LOMA or LOMR-F request must be submitted with either a completed FEMA MT-EZ or MT-1 package, whichever is appropriate. This certificate is used only to certify building elevations. A separate certificate is required for floodproofing. Under the NFIP, non-residential buildings can be floodproofed up to or above the Base Flood Elevation (BFE). A. floodproofed building is a building that has been designed and constructed to be watertight (substantially impermeable to floodwaters) below the BFE. Floodproofing of residential buildings is not permitted under the NFIP unless FEMA has granted the community an exception for residential floodproofed basements. The community must adopt standards for design and construction of floodproofed basements before FEMA will grant a basement exception. For both floodproofed non- residential buildings and residential floodproofed basements in communities that have been granted an exception by FEMA, a floodproofing certificate is required. Additional guidance can be found in the FEMA Floodplain Management Bulletin about using the Elevation Certificate, - available on FEMA's website at www.fema.gov/fima/fpmbul..shtm. Click on "FEMA 467-1 Elevation Certificate Cover and Bulletin." " tl.S. DEPARTMENT OF -HOMELAND SECURITY .Federal Emergency Management Agency National Flood insurance Program ELEVATION CERTIFICATE Important: Read the instructions on pages 1-8. SECTION A - PROPERTY INFORMATION OMB No. 1660-0008 Expires February 28, 2009, Forinsurance'Company Ose:. A1, uilding gwner's Narqe• P.olicy Number clim { V. Bull dress.$nudingApt., Unit, Suite and/or g. No.) or P.O. Route and Box No.. Company NAIC Number State A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.)BCE2;!36 A5: Latitude/Longitude: Lat. Long. Horizontal Datum: ❑ NAD 1927 ❑ NAD 1983 A6 ';Attach. at'least.2 photographs 'of the building if the ei rllficat6os being usdflo' obtain flood insurance. , A7. Building Diagram Number A8. For a building with a Brawl space or enclosure(s); provide: A9c' For a building with an attached 'garage, provide: a) Square footage of crawl, space or enclosure(s) sq ft a) Square footage of:attached garage sq ft b) No. of permanent flood openirigs•in the crawl space or b) No. of permanent flood openings inthe attached garage enclosure(s) walls within 1.0 foot above adjacent grade walls within 1.0 foot above adjacent grade c) Total nef area of flood_openings in A8.b sq -in c) Total net`area of flood openings in Ag.b ` sq in SECTION B`- FLOOD INSUPANCEAATEWP (FIRM),INPORMATION BJ NFIP Community Name 8 Corn i Number B2. Coun ame B3. State. n �Z �. B4. Map'/Panel Number B5. Suffix B6. FIRM -Index B7..FIRM Panel B8. Flood B9. Base Flood Elevatiori(s) (Zone I�L1iCOSJ1 " Dat ?�LE=_�. te ZOne(s)AO use base flood depth) B10. Indicate the source of the Base Flood Elevation (BFE)` data or base flood depth entered in Item B9. ' ❑ FIS Profile. FIRM ❑ 'Community Determined ❑ Other (Describe) IB11. Indicate elevation datum used for BFE in Item 99: &NGVD 1929 ❑ NAVD1988 ❑ Other (Describe) 812. 1s the building located in a. Coastal Barrier Resources System (CBRS) area or Otherwise Protected. Area (OPA)? ❑ Yes No Designation Date ❑ CBRS ❑ OPA SECTION C - BUILDING.ELEVATION INFORMATION (SURVEY.REQUIRED) C1: Building elevations are based on: ❑ Construction. Drawings' ❑ Building Under Construction' ❑ Finished Construction 'A new Elevation Certificate'will be required when construction of the building is complete. C2. Elevations —Zones AI-A30, AE, AH, A.(with BFE), VE, V1-V30, V (with BFE), AR, ARIA, ARIAE, AR/A1-A30, ARIAH, AR/AO. Complete Items C2.a-g below according to the building diagram specified in Item A7. Benchmark;Utilked. Vertical Datum Conversion/Comments Check the measurement used. a) Top of bottom floor(rncluding basement, crawl space, or enclosure floor) ❑ ;feet ❑ meters (Puerto Rico only) b) Top of the next'higher, floor_._❑ feet 0 meters (Puerto Rico only) .. c) Bottom of the lowest horizontal structural member (V Zones only) _C] feet ❑ meters (Puerto Rico only) d) Attached garage'(top of slab) _❑ feet ❑ meters (Puerto Rico only) e) Lowest elevation of machinery or equipment servicing the building' _❑ feet ❑ ureters (Puerto Ried only) (Describe type.,of equipment in Comments) . f) Lowest adjacent (finished) grade (LAG) _❑ feet ❑meters (Puerto Rico only) g)-Highest adjacent (finished) grade (HAG) _❑ feet ❑ meters (Puerto Rico only) SECTION D.--SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION i his certification is to. be signed and sealed by a land surveyor, engineer, or architect authorized bylaw to certify ele information. I certify that the information on this Certificate represents my best efforts to interpret the data available. 1 understand that any false statement maybe punishable by fine orimprisonment under 18 U.S. Code, Section 1001 ❑ Check here if comments are provided on back of form. Certifier's Name License Number Title Company Name Address City State ZIP Code ,- _Signature Date Telephone PLACE SEAL HERE •r FEMA Form 81-31, February 2006 See reverse side for continuation. Replaces all previous editions I IMPORTANT: In these spaces, copy the corresponding information from ei dllon A. For Insurance Company Use: v ' Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. :Policy Number:: r� City State ZIP Code 'Company-NAIC Number SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) i Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Comments I Signature Date ❑ Check here if attachments SECTION E - BUILDING ELEVATION INFORMATIONJSURVEY NOT REQUIRED).FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B. and C. For Items E1-E4, use natural grade,.if available. Check the measurement used. In Puerto Rico only, enter meters, E1. Provide elevation information for the following and check the appropriate boxes to show whether -the elevation is above or below the highest adjacent grade (HAG) and,the lowest adjacent grade (LAG). a) Top of bottomrfloor-(including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or El below the HAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet Elmeters ❑ above or Elbelow the LAG. E2: For Building Diagrams 6-8 with permanent flood openings provided in;Sect'ion A Items:8 and/or 9 (see a 'e 8•otanstructions), the next higher floor (elevation C2.b in the diagrams).of the building is _ ❑ feet ❑ meters . ❑ above or LJ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters - ❑ above•or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is _ ❑ feet ❑ meters ❑ above or ❑ below the HAG. ' E5. Zone AO only: if no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ElYes ❑ No ❑ Unknown.. The local official must certify this- information in Section G. SECTION F PROPERTY OWNER (OR.OWNER'S REPRESENTATIVE) CERTIFICATION • The property owner or owner's authorized representative who completes Sections A. B, and E for Zone•A (without a FEMA-issued or community -issued BFE) - or Zone •AO must sign here. The statements in. Sections A, B, and-E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments G - COMMUNITY INFORMATION The local official who is authorized by:law or ordinance. to administer the community's floodplain management ordinance can complete Sections A, B., C (or E), and G of this Elevation Certificate. Complete -the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. G1. ❑ The information in Section C was'taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community bt6afcompleted Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE)'.or Zone AO. G3. ❑ The following information (Items`G4.-G9) is provided. for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for. ❑ New Construction ❑ Substantial Improvement G8. Elevation -of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters (PR) Datum Gg. BFE or (in Zone AO) depth of flooding at the building. site: ❑ feet "Elmeters (PR) Datum Local Official's Name Title Community Name Telephone i Signature Date Comments ❑ Check here if attachments ` FEMA Form 81-31, February 2006 Replaces all previous editions y } 'a Building Photographs See Instructions for Item A6. For. Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number City State ZIP Code Company NAIC Number;, If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, `Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. r s Building Photographs Continuation Paoe For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number City State ZIP Code Company NAIC Number If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." ,I ,1 i y 1 INSTRUCTIONS FOR COMPLETING THE ELEVATION CERTIFICATE The Elevation Certificate is to be completed by a land surveyor, engineer, or architect who is authorized by law to certify elevation information when elevation information is required for Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, or AR/AO. Community officials who are authorized bylaw or ordinance to provide floodplain management information may also complete this form. For Zones AO and A (without BFE), a community ` official, a property owner, or an owner's representative may provide information on this certificate, unless the elevations are intended for use in supporting a request for a LOMA or LOMR-F. Certified elevations must be included if the purpose of completing the Elevation Certificate is to obtain a LOMA or LOMR-F. The property owner, the owner's representative, or local official who is authorized by law to administer the community floodplain ordinance can complete Section A and Section B. The partially completed form can then be given to the land surveyor, engineer, or architect to complete Section C. The land surveyor, engineer, or architect should verify the information provided by the property owner or owner's representative to ensure that this certificate is complete. In Puerto Rico only, elevations for building information and flood hazard information may be entered in meters. SECTION A — PROPERTY INFORMATION Items Al: A4. This section identifies,the building, its location, and its owner. Enter the name(s) of the building owner(s), the building's complete street address, and the lot and block numbers. If the building's address is different from the owner's address, enter the address of the building being certified. If the address is a rural route or a Post Office box number, enter the lot - and block numbers, the tax parcel number, the legal description, or an abbreviated location description based on distance and - direction from a fixed point of reference. For the purposes of this certificate, "building" means both a building and a manufactured (mobile) home. -A map may be attached to this certificate to show the location of the building on the property. A tax map, FIRM, or detailed community map is appropriate. If no map is available, provide a sketch of the property location, and the location of the building on the property. Include appropriate landmarks such as nearby roads, intersections, and bodies of water. For building use, indicate whether the building is residential, non-residential, an addition to an existing residential or non-residential building, an accessory building (e.g., garage), or other type of structure. Use the Comments area of the appropriate section if needed, or attach additional comments!. Item A5. Provide latitude and longitude coordinates for the center of the front of the building. Use either decimal degrees (e.g., 39.5043°,-110.7585°) or degrees, minutes, seconds (e.g., 39' 30' 15.5", -110' 45' 30.7") format. If decimal degrees are used, provide coordinates to at least 4 decimal places or better. When using degrees, minutes, seconds, provide seconds to at least 1 decimal place or better. The latitude and longitude coordinates must be accurate within 66 feet. If the Elevation Certificate is being certified by other than a licensed surveyor, engineer, or architect, this information is not required. Provide the type of datum used to obtain the latitude and longitude. FEMA prefers the use of NAD 1983. Item A6. If the Elevation Certificate is being used to obtain flood insurance through the NFIP, the certifier must provide at least two photographs showing the front and rear of the building taken within 90 days from the date of certification. The photographs must be taken with viewsconfirming the building description and diagram number provided in Section A. If the building has split-level or multi -level areas, provide at least two additional photographs showing side views of the building. All photographs must be in color and measure at least 3"0". Digital photographs are acceptable. Item A7. Select the diagram on pages 7-8 that best represents the building. Then enter the diagram number and use the diagram to identify and determine the appropriate elevations requested in Items C2.a-g. If you are unsure of the correct diagram, select the diagram that most closely resembles the building being certified. Item A8.a Provide the square footage of the crawl space or enclosure(s) below the lowest elevated floor of an elevated building with or without permanent flood openings. Take the measurement from the outside of the crawl space or enclosure(s). Examples of elevated buildings constructed with crawl space and enclosure(s) are shown in Diagrams 6-8 on page 8. Diagram 2 or 4 should be used for a building constructed with a crawl space floor that is below the exterior grade on all sides. - Items A8.b-c Enter in Item A8.b the number of permanent flood openings in the crawl space or enclosure(s) walls that are no higher than 1.0 foot above the adjacent grade. Estimate the total net area of all such permanent flood openings in square : inches, excluding any bars, louvers, or'other covers of the permanent flood openings, and enter the total in Item A8.c. If the net Instructions —Page 1 s area cannot be reasonably estimated, provide the size of the flood openings without consideration of any covers and indicate in the Comments area the type of cover that exists in the flood openings. If the crawl space or enclosure(s) walls have no permanent openings within 1.0 foot above adjacent grade, enter "0" (zero) in Items A8.b-c. Item A9.a Provide the square footage of the attached garage with or without permanent flood openings. Take the measurement from the outside of the garage. Items A9.b-c Enter in Item A9.b the number of permanent flood openings in the attached garage that are no higher than 1.0 foot above the adjacent grade. This includes any openings that are in the garage door that are no higher than 1.0 foot above the adjacent grade. Estimate the total net area of all such permanent flood openings in square inches and enter the total in Item A9.c. If the garage has no permanentflood openings within 1.0 foot above adjacent grade, enter "0" (zero) in Items A9.b-c. SECTION B : FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Complete the Elevation Certificate on,the basis of the FIRM in effect at the time of the certification. The information for Section B is obtained by reviewing the FIRM panel that includes the building's location. Information about the current FIRM is available from the Federal Emergency Management Agency (FEMA) by calling 1-800-358-9616. If a setter of Map Amendment (LOMA) or Letter of Map Revision (LOMR-F) has been issued by FEMA, please provide the letter date and case number in the Comments area of Section D or Section G, as appropriate. For a building in an area that has been annexed by one community but is shown on another community's FIRM, enter the community name and 6-digit number of the annexing community in Item B 1, the name of the new county in Item B2, and the FIRM index date for the annexing community in Item B6. Enter information from the actual FIRM panel that shows the - building location, even if it is the FIRM for the previous jurisdiction, in Items B4, 135, 137, 138, and B9. Item B1. NFIP Community Name & ICommunity Number. Enter the complete name of the community in which the building is located and the associated 6-digit community number. For a newly incorporated community, use the name and 6-digit number of the new community. Under the NFIP, a "community" is any State or area or political subdivision thereof, or any Indian tribe or authorized native organization, that has authority to adopt and enforce floodplain management regulations for the areas within its jurisdiction. To determine the current community number, see the NFIP, Community Status Book, available on FEMA's web site at htip://www.fcma.gov/fema/esb.shtm, or call 1-800-358-9616. Item B2. County Name. Enter the name of the county or counties in which the community is located. For an unincorporated area of a county, enter "unincorporated area." For an independent city, enter "independent city." Item B3. State. Enter the 2-letter state abbreviation (for example, VA, TX, CA). Items B4: B5. Map/Panel Number and Suffix. Enter the 10-character "Map Number" or "Community Panel Number" shown on the FIRM where the building or manufactured (mobile) home is located.. For maps in a county -wide format, the sixth character of the "Map Number" is the Metter "C" followed by a four -digit map number. For maps not in a county -wide format, enter the "Community Panel Number" shown on the FIRM. Item B6. FIRM Index Date. Enter the effective date or the map revised date shown on the FIRM Index. Item B7. FIRM Panel Effective/Revised Date. Enter the map effective date or the map revised date shown on the FIRM panel. This will be the latest of all dates shown on the map. The current FIRM panel effective date can be determined by calling 1-800-358-9616. Item B8. Flood Zone(s). Enter the flood zone, or flood zones, in which the building is located. All flood zones containing the letter "A" or "V" are considered Special Flood Hazard Areas. The flood zones are A, AE; Al-A30, V, VE, VI-V30, AH, AO, AR, AR/A, AR/AE, AR/A1-A30, ARIAH, and AR/AO. Each flood zone is defined in the legend of the FIRM panel on which it appears. Instructions — Page 2 .Q Item B9. Base Flood Elevation(s). Using the appropriate Flood Insurance Study (FIS) Profile, Floodway Data Table, or FIRM panel, locate the property and ',enter the BFE (or base flood depth) of the building site. If the building is located in more than one flood zone in Item B8, list all appropriate BFEs in Item B9. BFEs are shown on a FIRM or FIS Profile for Zones A1- • A30, AE, AH, V1-V30, VE, AR, AR/A, AR/AE, AR/A 1-A30, AR/AH, and AR/AO; flood depth numbers are shown for Zone AO. Use the AR BFE if the building is located in any of Zones AR/A, AR/AE, AR/A1-A30, AR/AH, or AR/AO. In A or V zones where BFEs are not provided on the FIRM, BFEs may be available from another source. For example, the community may have established BFEs or obtained BFE data from other sources for the building site. For subdivisions and other developments of more than 50 lots or 5 acres, establishment of BFEs is required by the community's floodplain management ordinance. If a BFE is obtained from another source, enter the BFE in Item B9. In an A Zone where BFEs are not available, ` complete Section E and enter N/A for Section B, Item B9. Enter the BFE to the nearest tenth of a foot (nearest tenth of a meter, in Puerto Rico). Item B10. Indicate the source of the BFE that you entered in Item B9. If the BFE is from a source other than FIS Profile, FIRM, or community, describe the source of the BFE. Item B11. Indicate the elevation datum to which the elevations on the applicable FIRM are referenced as shown on the map legend. The vertical datum is shown in the Map Legend and/or the Notes to Users on the FIRM. Item B12. Indicate whether the building is located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected A. -ea (OPA). (OPAs are portions of coastal barriers that are owned by Federal, State, or local governments or by certain non- profit organizations and used primarily for natural resources protection.) Federal flood insurance is prohibited in designated CBRS areas or OPAs for buildings or! manufactured (mobile) homes built or substantially improved after the date of the CBRS . or OPA designation. For the first CBRS designations, that date is October 1, 1983. An information sheet explaining CBRS areas and OPAs may be obtained on FEMA's web site at littp://www.fema.gov/fhin/fmc cbrs.shtm. SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Complete Section C if the building is'located in any of Zones Al-A30, AE, AH, A (with BFE), VE, VI-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, or AR/AO, or if this certificate is being used to support a request for a LOMA or LOMR-F. If the building is located in Zone AO or Zone A (without BFE), complete Section E instead. To ensure that all required elevations are obtained, it may be necessary to enter the building (for instance, if the building has a basement or sunken living room, split-level construction, or machinery and equipment). Surveyors may not be able to gain access to some crawl spaces to shoot the elevation of the crawl space floor. If access to the crawl space is limited or cannot be gained, follow one of these procedures. • Use a yardstick or tape measure to; measure the height from the floor of the crawl space to the "next higher floor," and then subtract the crawl space height from the elevation of the "next higher floor." If there is no access to the crawl space, use the exterior grade next to the structure to measure the height of the crawl space to the "next higher floor." • Contact the local floodplain administrator of the community in which the building is located. The community may have documentation of the elevation of the crawl space floor as part of the, permit issued for the building. • If the property owner has documentation or knows the height of the crawl space floor to the next higher floor, try to verify this by looking inside the crawl space through any openings or vents. In all three cases, provide the elevation in the Comments area of Section D on the back of the form and a brief description of how the elevation was obtained. Item C1. Indicate whether the elevations to be entered in this section are based on construction drawings, a building under construction, or finished construction., For either of the first two choices, a post -construction Elevation Certificate will be required when construction is complete. If the building is under construction, include only those elevations that can be surveyed in Items C2.a-g. Use the Comments area of Section D to provide elevations obtained from the construction plans or drawings. Select "Finished Construction" only when all machinery and/or equipment such as furnaces, hot water heaters, heat pumps, air conditioners, and elevators and their associated equipment have been installed and the grading around the building is completed. = Item C2. A field survey is required for Items C2.a-g. Provide the benchmark utilized, the vertical datum for that benchmark, and any datum conversion necessary. Most control networks will assign a unique identifier for each benchmark. For example, the National Geodetic Survey uses the Permanent Identifier (PID). For the benchmark utilized, provide the PID or other Instructions —Page 3 'unique identifier assigned by the maintainer of the benchmark. Also provide the vertical datum for the benchmark elevation. Show the conversion from the field survey datum used if it differs from the datum used for the BFE entered in Item B9 and indicate the conversion software used. All elevations for the certificate, including the elevations for Items C2.a-g, must be -referenced to the datum on which 'the BFE is based. Show the datum conversion, if applicable, in this section or in the Comments area of Section D. For property experiencing ground subsidence, the most recent reference mark elevations must be used for determining building elevations. However, when subsidence is involved, the BFE should not be adjusted. Enter elevations in Items C2.a-g to the nearest tenth of a foot (nearest tenth of a meter, in Puerto Rico). Items C2.a-d Enter the building elevations (excluding the attached garage) indicated by the selected building diagram (Item A7.) in Items C2.a-c. If there is an attached garage, enter the elevation for top of attached garage slab in Item C2.d. (Because elevation for top of attached garage slab is self-explanatory, attached garages are not illustrated in the diagrams.) If the building is located in a V zone on the FIRM, complete Item C2.c. If the flood zone cannot be determined, enter elevations for all of Items C2.a-g. For buildings in zones,'elevations a, b, d, and a should be measured at the top of the floor. For buildings in V zones, elevation c must be measured at the bottom of the lowest horizontal structural member of the floor (see drawing below). For buildings elevated on a crawl space, Diagram 8, enter the elevation of the top of the crawl space floor in Item C2.a, whether or not the crawl space has permanent flood openings (flood vents). If any item does not apply to the building, enter "XIA "for not applicable. BUILDING ON BUILDING WITH BUILDING ON PILES, SLAB BASEMENT PIERS, OR COLUMNS A ZONES V ZONES I/ C2.a A ZONES 1 V ZONES C2.a INNIM1\1 10\ a A ZONES C2.a N C2.c BASE FLOOD ELEVATION C2.c BASE FLOOR':::: \ ;.::..•.'<'; ADJACENT ELEVATION::..:•;..'.:' ?:'.:.;:'•':: �'='a.i''•:!.;;;, :. '• �•''. ,'DJACENT i GRADE � 3F2ADE Item C2.e Enter the lowest platform elevation of at least one of the following machinery and equipment items: elevators and their associated equipment, furnaces, hot water heaters, heat pumps, and air conditioners in an attached garage or enclosure or on an open utility platform that provides utility services for the building. Note that elevations for these specific machinery and equipment items are required in order to rate the building for flood insurance. Local floodplain management officials are required to ensure that all machinery;and equipment servicing the building are protected from flooding. Thus, local officials may require that elevation information for all machinery and equipment, including ductwork, be documented on the Elevation Certificate. If the machinery and/or equipment is mounted to a wall, pile, etc., enter the platform elevation of the machinery and/or equipment. Indicate machinery'/equipment type in the Comments area of Section D or Section G, as appropriate. If this item does not apply to the building, enter "NIA "for not applicable. Items C2.f-g• Adjacent grade is defined as the elevation of the ground, sidewalk, patio slab, or deck support immediately next to the building. If the certificate is to be used to support a request for a LOMA or LOMR-F, provide in the Comments area the lowest adjacent grade elevation measured at the deck support or stairs if that elevation is lower than the building's lowest adjacent grade. For Zone AO, use the natural grade elevation, if available: This measurement must be to the nearest tenth of a foot (nearest tenth of a meter, in Puerto Rico) if this certificate is being used to support a request for a LOMA or LOMR-F. SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION Complete as indicated. This section of the Elevation Certificate may be signed by only a land surveyor, engineer, or architect who is authorized by law to certify elevation information. Place your license number, your seal (as allowed by the State licensing board), your signature, and th'e date in the box in Section D. You are certifying that the information on this certificate represents your best efforts to interpret the data available and that you understand that any false statement may be punishable Instructions — Page 4 'by fine or imprisonment under 181 U.S. Code, Section 1001. Use the Comments area of Section D, on the back of the certificate, to provide datum, elevation, or other relevant information not specified on the front. SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO & ZONE A (WITHOUT BFE) Complete Section E if the building is located in Zone AO or Zone A (without BFE). Otherwise, complete Section C instead. Explain in the Section F Comments area if the measurement provided under Items El.- E4. is, based on the "natural grade." ` Items ELa and b Enter in Item ELa the height to the nearest tenth of a foot (tenth of a meter in Puerto Rico) of the top of the bottom floor (as indicated in the applicable diagram) above or below the highest adjacent grade (HAG). Enter in Item El.b the height to the nearest tenth of a foot (tenth of a meter in Puerto Rico) of the top of the bottom floor (as indicated in the applicable diagram) above or below the lowest adjacent grade (LAG). For buildings in Zone AO, the community's floodplain management ordinance requires the lowest floor of the building be elevated above the highest adjacent grade at least as high as the depth number on, the FIRM. Buildings in Zone A (without BFE) may qualify for a lower insurance rate if an engineered BFE is developed at the site. i Item E2. For Building Diagrams 6-8 !,with permanent flood openings (see page 8), enter the height to the nearest tenth of a foot (tenth of a meter in Puerto Rico) of 'the next higher floor or elevated floor (as indicated in the applicable diagram) above or below the highest adjacent grade (HAG). Item E3. Enter the height to the nearest tenth of a foot (tenth of a meter in Puerto Rico), in relation to the highest adjacent grade next to the building, for the top of attached garage slab. (Because elevation for top of attached garage slab is self- explanatory, attached garages are not illustrated in the diagrams.) If this item does not apply to the building, enter "N/A" for not applicable. ~. Item E4. Enter the height to the nearest tenth of a foot (tenth of a meter in Puerto Rico), in relation to the highest adjacent grade next to the building, of the platform elevation that supports the machinery and/or equipment servicing the building. Indicate machinery/equipment type in the Comments area of Section F. If this item does not apply to the building, enter "NIA "for not applicable. Item E5. For those communities where this base flood depth is not available, the community will need to determine whether the top of the bottom floor is elevated in accordance with the community's floodplain management ordinance. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION Complete as indicated. This section! is provided for certification of measurements taken by a property owner or property owner's representative when responding to Sections A, B, and E. The address entered in this section must be the actual mailing address of the property owner'or property owner's representative who provided the information on the certificate. SECTION G - COMMUNITY INFORMATION (OPTIONAL) Complete as indicated. The community official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Section C may be filled in by the local official as provided in the instructions below for Item G1. If the authorized community official completes Sections C, E, or G, complete the appropriate item(s) and sign this section. Check Item G1. if Section C is completed with elevation data from other documentation, including elevations obtained from the Community Rating System Elevation Software, that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to � certify elevation information. Indicate the source of the elevation data and the date obtained in the Comments area of Section G. If you are both a community official and a licensed land surveyor, engineer, or architect authorized by law to certify elevation information, and you performed the actual survey for a building in Zones A1- A30, AE, AH, A (with BFE), VE, V1 V30, V (with BFE), AR, AR/A, AR/A1-A30, AR/AE, AR/AH, or AR/AO, you must also complete Section D. Check Item G2. if information is entered in Section E by the community for a building in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. ' Instructions — Page 5 .0 0 CCheck Item G3. if the information in Items G4.-G9. has been completed for community floodplain management purposes to document the as -built lowest floor elevation of the building. Section C of the Elevation Certificate records the elevation of various building components but does not determine the lowest floor of the building or whether the building, as constructed, Complies with the community's floodplain management ordinance. This must be done by the community. Items G4.-G9. provide a way to document these determinations. Item G4. Permit Number. Enter the permit number or other identifier to key the Elevation Certificate to the permit issued for the building. • Item G5. Date Permit Issued. Enter the date the permit was issued for the building. Item G6. Date Certificate of Compliance/Occupancy Issued. Enter the date that the Certificate of Compliance or Occupancy or similar written official documentation of as -built lowest floor elevation was issued by the community as evidence that all work authorized by the floodplain development permit has been completed in accordance with the community's floodplain management laws or ordinances. Item G7. New Construction or Substantial Improvement. Check the applicable box. "Substantial Improvement" means any reconstruction, rehabilitation, addition, or other improvement of a building, the cost of which equals or exceeds 50 percent of the market value of the building before the start of construction of the improvement. The term includes buildings that have incurred substantial damage, regardless of the actual repair work performed. Item G8. As -built lowest floor elevation. Enter the elevation of the lowest floor (including basement) when the construction of the building is completed and a final inspection has been made to confirm that the building is built in accordance with the permit, the approved plans, and the community's floodplain management laws or ordinances. Indicate the elevation datum used. Item G9. BFE..Using the appropriate FIRM panel, FIS Profile, or other data source, locate the property and enter the BFE (or base flood depth) of the building site. Indicate the elevation datum used. Enter your name, title, and telephone number, and the name of the community. Sign and enter the date in the appropriate blanks. Instructions — Page 6 A BUILDING DIAGRAMS The following eight diagrams illustrate various types of buildings. Compare the features of the building being - certified with the features shown in the diagrams and select the diagram most applicable. Enter the diagram number in Item AT, the square footage of crawl space or enclosure(s) and the area of flood openings in square inches in Items A8.a-c, the square footage of attached garage and the area of flood openings in square inches in Items A9.a-c, and the elevations in Items C2.a-g. In A. zones, the floor elevation is taken at the top finished surface of the floor indicated; in V zones, the floor elevation is taken at the bottom of the lowest horizontal structural member (see drawing in instructions for Section Q. DIAGRAM 3 All split-level buildings that are slab -on -grade, either detached or row type (e.g., townhouses); with or without attached garage. Distinguishing Feature — The bottom floor (excluding garage) is at or above ground level (grade) on at least one side .' C2.a C2.b HIGHER i FLOORS NEXT HIGHER GRADE BOTTOM FLOOR 1 LOOR a� a ne i. m •existing grade) DIAGRAM 2 All single- and multiple -floor buildings with basement (other than split-level) and high-rise buildings with basement, either detached or row type (e.g., townhouses)• with or without attached ara e. Distinguishing Feature — The bottom floor (basement or underground garage) is below ground level (grade) on all sides. Buildings constructed above crawl spaces that are below grade on all sides should also use this diagram.' C2.a B ' C2.b NEXT HIGHER FLOOR GRADE BOTTOM FLOOR \�1 (BASEMENT) 'fe: '•'C"ed�:ti' rin n - - ><4,ti.{Z•::9.•..e�cistirig'jraiie.).::::... .......... ............... ......... DIAGRAM 4 All split-level buildings (other than slab -on -grade), either detached or row type (e.g., townhouses); with or without attached garage. Distinguishing Feature — The bottom floor (basement or underground garage) is below ground level (grade) on all sides. Buildings constructed above crawl spaces that are below grade on all sides should also use this diagram.' C2.b C2.a ' HIGHER GRADE FLOORS ' NEXT HIGHER .BOTTOM FLOOR FLOOR BASEMENT - Yr•' •'iy::" iir:: �dser'rri'' "edb` - ��C2`:f g.. existing grade) * A floor that is below ground level (grade) on all sides is considered a basement even if the floor is used for living purposes, or as an office, garage, workshop, etc. Instructions — Page 7 DIAGRAM 5 All buildings elevated on piers, posts, piles, columns, or parallel shear walls. No obstructions below the elevated floor. Distinguishing Feature — For all zones, the area below the elevated floor is open, with no obstruction to flow of flood waters (open lattice work and/or readily removable insect screening is permissible). C2.b C2.a GRADE NEXT HIGHER i FLOOR /I ELEVATED FLOOR -9 ) existing grade) C2.0 I (For V zones only) DIAGRAM 7 All buildings elevated on full -story foundation walls _with a partially or fully enclosed area below the elevated floor. This includes walkout levels, where at least one side is at or above grade. The principal use of this building is located in the elevated floors of the building. Distinguishing Feature — For all zones, the area below the elevated floor is enclosed, either partially or fully. In A Zones, the partially or fully enclosed area below the elevated floor is with or without openings" present in the walls of the enclosure. Indicate information about enclosure size and openings in Section A — Property Information. C2.a NEXT HIGHER C2.b / FLOOR GRADE WALKOUT LEVEL C2'g \ C2.f (ENCLOSURE) / A8.b-c OPENINGS" DIAGRAM 6 All buildings elevated on piers, posts, piles, columns, or parallel shear walls with full or partial enclosure below the elevated floor. Distinguishing Feature — For all zones, the area below the elevated floor is enclosed, either partially or fully. In A Zones, the partially or fully enclosed area below the elevated floor is with or without openings" present in the walls of the enclosure. Indicate information about enclosure size and openings in Section A — Property Information. NEXT HIGHER / \ FLOOR C2.a ELEVATED FLOOR C2.b A8.a-c enclosure size & openings, if any. existing grade) ( C2.0 ) (For V zones only) DIAGRAM 8 All buildings elevated on a crawl space with the floor of the crawl space at or above grade on at least one side, with or without an attached garage. Distinguishing Feature — For all zones, the area below the first floor is enclosed by solid or partial perimeter walls. In all A zones, the crawl space is with or without openings" present in the walls of the crawl space. Indicate information about crawl space size and openings in Section A — Property Information. C2.a i i C2.b C2.f NEXT HIGHER FLOOR a C2.g ** An "opening" is defined as a permanent opening in a wall that allows for the free passage of water automatically in both directions without human intervention. Under the NFIP, a minimum of two openings is required for enclosures or crawl spaces with a total net area of not less than one square inch for every square foot of area enclosed. Each opening must be on different sides of the enclosed area. If a building has more than one enclosed area, each area must have openings on exterior walls to allow floodwater to directly enter. The bottom of the openings must be no higher than one foot above the grade underneath the flood vents. Alternatively, you may submit a certification by a registered professional engineer or architect that the design will allow for the automatic equalization of hydrostatic flood forces on exterior walls. A window, a door, or a garage door is not considered an opening. Instructions — Page 8 Y ' OFFICE USE ONLY: DATE FILED: REVISION FEE: 160 40 PERMIT # 070 kcl I RECEIPT # ST. LUCIE COUNTY PUBLIC WORKS DEPARTMENT CODE COMPLIANC: 2300 VIRGINIA A FORT PIERCE, FL (772) 462-1E APPLICATION FOR BUILDING PROJECT INFOW 1. LOCATION/SITE' 2. DETAILED DESCRIPTION OF PROJECT 3. CONTRACTOR INFORMATION: ST. of FL REGJCERT. # BUSINESS NAME: QUALIFIERS NAME: ADDRESS: .CITY: - PHONE (DAYTIME): 4. OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY:' PHONE/CELL: 5. ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS:, CITY: PHONE (DAYTIME): ST. LUCIECTY-CERT. - STATE:/ llur: -n FAX: STATE: ZIP: FAX: STATE: FAX: ZIP: 1' y BRAOEN & BRAOEN, A. I. A., P. A. -Wrchded,5 & 'Planners 417 COCONUT AVENUE, STUART,, FLORIOA 3499B TELEPHONE: (772) 2B7-B25B FAX (772) 2B7-B2B3 #AAC-000032 St. Lucie County Building Department RE: William Residence Mr. Daves, The following items have been changed on our plans and are shown on the attached revised sheets: - A spiral stair has been added to the rear of the residence. - The insulation has been changed to now be Taylored foam Core -Fill 500 R-8.0 at all block walls. If you have any questions please feel free to call me at (772) 287-8258. Rankyou, 0"Ut Urban Braden & Braden AIA PA 0x mm O m r�-r@aMc'�" frn�mV M�-m ref--0o Z A in 0 r V 0 ,9 n 30 � 9 &�0C)o 0Q�00 myy a y 0 June 17, 2009 Asakx rV S' '6•_2 �4J'i J', FORM 60OA-2004R FLORIDA ENEF FOR BUILDI Florida Depi Residential Whole DE uge® 4.5.2 Project Name: 07GROZA-williams M M M� RM '80W: - "m' 'GROZA BUILDERS Address: 511 S.W. PORT ST LUCIE BLVD Permitting Office: ST LUCIE City, State: PORT ST LUCIE, FL 34953 Permit Number: Owner: GROZA BUILDERS, INC Jurisdiction Number: 661000 Climate Zone: Central 1. New construction or existing New _ 2. Single family or multi -family Single family _ 3. Number of units, if multi -family 1 4. Number of Bedrooms 5 _ 5. Is this a worst case? No 6. Conditioned floor area (ftz 5951 ft2 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a. (Sngle Default)l 63 1.0 ft2 _ b. SHGC: (or Clear or Tint DEFAULT) 7b. (Tint)1631.0 ftz _ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 223.0(p) ft _ b. Raised Wood, Adjacent R=11.0, 2360.02 _ c. N/A _ 9. Wall types a. Concrete, Ext Insul, Exterior R=8.0, 4356.0 ft2 _ b. Frame, Wood, Adjacent R=11.0, 460.0 ft2 _ c. Concrete, Int Insul, Adjacent =8?0 ft2 _ d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic R=30.0, 3950.0 ft2 b. N/A c. N/A _ 11. Ducts. _ a. Sup: Con. Ret: Con. AH: Interior Sup. R=6.0, 100.0 W b. 2 Others 200.0 ft _ 12. Cooling systems a. Central Unit b. Central Unit c. Central Unit 13. Heating systems a. Electric Heat Pump b. Electric Heat Pump c. Electric Heat Pump 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.27 Total as -built points: 57767 PASS Total base points: 59974 I hereby certify that the plans and specifications covered by this calculation are in compliance with theFloridaEnergy PREPARED BY:2r-CQ C���OOI 1 r1Q DATE: �n - M - Ocl I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 'rPredominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge@) (Version: FLRCSB v4.5.2) Cap: 58.0 kBtu/hr _ SEER:15.50 _ Cap: 58.0 kBtu/hr _ SEER:15.50 _ Cap: 36.0 kBtu/hr _ SEER: 18.00 Cap: 58.0 kBtu/hr _ HSPF:9.00 _ Cap: 58.0 kBtu/hr HSPF:9.00 _ Cap: 36.0 kBtu/hr _ HSPF: 9.00 Cap: 80.0 gallons EF: 0.86 PT, FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 PERMIT*: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 5951.0 24.35 26083.0 13ingle, Tint E 2.0 21.0 63.0 53.27 0.99 3337.0 2.Single, Tint E 6.5 10.0 144.0 53.27 0.65 4999.0 3.Single, Tint S 2.0 18.0 ' 60.0 39.84 0.99 2364.0 4.Single, Tint SW 2.0 18.0 15.0 47.31 1.00 707.0 53ingle, Tint W 2.0 18.0 30.0 47.90 0.99 1428.0 6.Single, Tint NW 2.0 18.0 15.0 33.43 1.00 499.0 7.Single, Tint N 20.0 9.5 64.0 24.46 0.64 995.0 8.Single, Tint W 11.0 9.0 128.0 47.90 0.50 3044.0 9.Single, Tint E 6.0 6.5 30.0 53.27 0.55 878.0 10.Single, Tint E 6.0 5.0 6.0 53.27 0.48 153.0 113ingle, Tint N 2.0 16.0 6.0 24.46 0.99 145.0 12.Single, Tint N 2.0 18.0 64.0 24.46 0.99 1554.0 13.Single, Tint S 20.0 9.0 64.0 39.84 0.49 1248.0 14.Single, Tint SW 6.0 6.0 15.0 47.31 0.52 366.0 15.Single, Tint W 13.0 9.5 48.0 47.90 0.48 1103.0 16.Single, Tint NW 5.0 6.5 15.0 33.43 0.69 347.0 17.Single, Tint E 2.0 6.5 102.0 53.27 0.87 4750.0 18.Single, Tint N 2.0 4.5 9.0 24.46 0.86 188.0 19.Single, Tint S 2.0 6.5 90.0 39.84 0.82 2935.0 20.Single, Tint S 2.0 3.5 6.0 39.84 0.66 158.0 21.Single, Tint SW 2.0 6.5 30.0 47.31 0.84 1192.0 22.Single, Tint W 2.0 6.5 122.0 47.90 0.87 5102.0 2Mingle, Tint NW 2.0 6.5 30.0 33.43 0.89 890.0 24.Single, Tint N 2.0 6.5 30.0 24.46 0.91 671.0 25.Single, Tint E 2.0 6.5 15.0 53.27 0.87 698.0 26.Single, Tint S 2.0 28.0 30.0 39.84 0.99 1186.0 27.Single, Tint SW 2.0 20.0 30.0 47.31 1.00 1416.0 28.Single, Tint W 2.0 28.0 30.0 47.90 1.00 1431.0 29.Single, Tint NW 2.0 28.0 30.0 33.43 1.00 1000.0 30.Single, Tint N 22.0 8.5 56.0 24.46 0.62 845.0 31.Single, Tint N 2.0 28.0 30.0 24.46 1.00 730.0 32.Single, Tint S 22.0 8.5 56.0 39.84 0.48 1069.0 33.Single, Tint W 18.0 8.5 56.0 47.90 0.42 1127.0 34.Single, Tint W 12.0 8.0 112.0 47.90 0.46 2492.0 .01 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge@ 4.5.2 K SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 PERMIT #: BASE AS -BUILT WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 570.0 0.70 399.0 1. Concrete, Ext Insul, Exterior 8.0 4356.0 0.08 326.7 Exterior 4356.0 1.90 8276.4 2. Frame, Wood, Adjacent 11.0 460.0 0.70 322.0 3. Concrete, Int Insul, Adjacent 8.0 110.0 0.38 41.3 Base Total: 4926.0 8675.4 As -Built Total: 4926.0 690.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 44.0 1.60 70.4 1.Adjacent Wood 44.0 2.40 105.6 Exterior 0.0 0.00 0.0 Base Total: ".0 70.4 As -Built Total: 44.0 105.6 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 3950.0 2.13 8413.5 1. Under Attic 30.0 3950.0 2.13 X 1.00 8413.5 Base Total: 3960.0 8413.5 As -Built Total: 3950.0 8413.5 FLOOR TYPES Area X BSPM = Points Type R-Value Area - X SPM = Points Slab 223.0(p) -31.8 -7091.4 1. Slab -On -Grade Edge Insulation 0.0 223.0(p -31.90 -7113.7 Raised 2360.0 -3.43 -8094.8 2. Raised Wood, Adjacent 11.0 2360.0 1.80 4248.0 Base Total: -15186.2 As -Built Total: 2683.0 -2865.7 INFILTRATION Area X BSPM = Points Area X SPM = Points 5951.0 14.31 85158.8 5951.0 ' 14.31 85158.8 Summer Base Points:113214.9 Summer As -Built Points: 142549.2 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 58000btuh ,SEERIEFF(15.5) Ducts:Con(S),Con(R),Int(AH),R6.0(INS) 142549 0.38 (1.00 x 1.150 x 0.85) 0.220 0.950 11177.9 (sys 2: Central Unit 58000btuh ,SEER/EFF(15.5) Ducts:Cori(S),Con(R),Gar(AH),R6.0(INS) 142549 0.38 (1.00 x 1.150 x 0.95) 0.220 0.950 12419.9 (sys 3: Central Unit 36000btuh ,SEER/EFF(18.0) Ducts:Con(S),Con(R),Gar(AH),R6.0(INS) 142549 0.24 (1.00 x 1.150 x 0.95) 0.189 0.950 6638.2 113214.9 0.3250 36794.8 142549.2 1.00 1.056 0.212 0.950 30306.0 EnergyGaugeT" DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 PERMIT #: BASE I AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Floor'Area Type/SC Overhang Ornt Len Hgt Area X WPM X WOF = Point .18 5951.0 9.11 9768.0 1.Single, Tint E 2.0 21.0 63.0 13.04 1.00 824.0 2.Single, Tint E 6.5 10.0 144.0 13.04 1.09 2051.0 3.Single, Tint S� 2.0 18.6 60.0 10.88 0.99 649.0 4.Single, Tint SW 2.0 18.0 15.0 12.36 1.00 185.0 5.Single, Tint W 2.0 18.0 30.0 13.80 1.00 413.0 6.Single, Tint NW 2.0 18.0 15.0 15.30, 1.00 229.0 7.Single, Tint N 20.0 9.5 64.0 15.38 0.99 969.0 8.Single, Tint W 11.0 9.0 128.0 13.80 1.10 - 1934.0 9.Single, Tint E 6.0 6.5 30.0 13.04 1.15 449.0 10.Single, Tint E 6.0 5.0 6.0 13.04 1.20 93.0 11.Single, Tint N 2.0 16.0 6.0 15.38 1.00 92.0 12.Single, Tint N 2.0 18.0 64.0 15.38 1.00 982.0 13.Single, Tint S 20.0 9.0 64.0 10.88 2.24 1560.0 14.Single, Tint SW 6.0 6.0 15.0 12.36 1.33 - 246.0 15.Single, Tint W 13.0 9.5 48.0 13.80 1.10 727.0 16.Single, Tint NW 5.0. 6.5 15.0 15.30 0.99 228.0 17.Single, Tint E 2.0 6.5 102.0 13.04 1.03 1364.0 18.Single, Tint N 2.0 4.5 9.0 15.38 0.99 137.0 19.Single, Tint S 2.0 6.5 90.0 10.88 1.09 1071.0 20.Single, Tint S 2.0 3.5 6.0 10.88 1.39 90.0 21.Single, Tint SW 2.0 6.5 30.0 12.36 1.05 389.0 22.Single, Tint W 2.0 6.5 12.2.0 13.80 1.02 1713.0 23.Single, Tint NW 2.0 6.5 30.0 15.30 1.00 457.0 24.Single, Tint N 2.0 6.5 30.0 15.38 1.00 459.0 25.Single, Tint E 2.0 6.5 15.0 13.04 •1.03 200.0 26.Single, Tint S 2.0 28.0- 30.0 10.88 1.00 325.0 27.Single, Tint SW 2.0 20.0 30.0 12.36 1.00 371.0 28.Single, Tint W 2.0 28.0 30.0 13.80 1.00 413.0 29.Single, Tint NW 2.0 28.0 30.0 15.30 1.00 458.0 30.Single, Tint N 22.0 8.5 56.0 15.38 0.98 847.0 31.Single, Tint N 2.0 28.0 30.0 ' 15,38 1.00 460.0 32.Single, Tint S 22.0 8.5 56.0 10.88 2.28 1387.0 33.Single, Tint W 18.0 8.5 56.0 13.80 1.11 858.0 34.Single, Tint W 12.0 8.0 112.0 13.80 1.10 1702.0 Total: 1631.0 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge@ 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 PERMIT #: I BASE AS -BUILT WALL TYPES Area X BWPM = Points Type R-Value . Area X WPM ,.= Points Adjacent 570.0 1.80 1026.0 1. Concrete, Ext Insul, Exterior 8.0 4356.0 1.33 5771.7 Exterior 4356.0 2.00 8712.0 2. Frame, Wood, Adjacent 11.0 460.0 1.80 828.0 3. Concrete, Int Insul, Adjacent 8.0 110.0 1.40 154.0 Base Total: 4926.0 9738.0 As -Built Total: 4926.0 6753.7 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 44.0 4.00 176.0 1.Adjacent Wood 44.0 5.90 259.6 Exterior 0.0 0.00 0.0 Base Total: 44.0 176.0 As -Built Total: ".0 259.6 CEILING TYPESArea X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 3950.0 0.64 2528.0 1. Under Attic 30.0 3950.0 0.64 X 1.00 2528.0 Base Total: 3950.0 2528.0 As -Built Total: 3950.0 2528.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 223.0(p) .-1.9 -423.7 1: Slab -On -Grade Edge Insulation 0.0 223.0(p 2.50 557.5 Raised 2360.0 -0.20 -472.0 2. Raised Wood, Adjacent 11.0 2360.0 1.80 4248.0 Base Total: -895.7 As -Built Total: 2583.0 4805.5 INFILTRATION Area X BWPM = Points Area X WPM = Points 5951.0 -0.28 -1666.3 5951.0 -0.28 -1666.3 Winter Base Points: 19638.0 Winter As -Built Points: 37012.5 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 58000 btuh ,EFF(9.0) Ducts:Con(S),Con(R),Int(AH),R6.0 37012.5 0.382 (1.000 x 1.160 x 0.87) 0.379 0.950 _ 5158.5 (sys 2: Electric Heat Pump 58000 btuh ,EFF(9.0) Ducts:Con(S),Con(R),Gar(AH),R6.0 37012.5 0.382 (1.000 x 1.160 x 0.95) 0.379 0.950 5607.0 (sys 3: Electric Heat Pump 36000 btuh ,EFF(9.0) Ducts:Con(S),Con(R),Gar(AH),R6.0 37012.5 0.237 (1.000 x 1.160 x 0.95) 0.379 0.950 3480.2 19638.0 0.5540 10879.5 37012.5 1.00 1.073 0.379 0.950 14302.4 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details I ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 PERMIT #: I BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 5 2460.00 12300.0 80.0 0.86 5 1.00 2631.63 1.00 13158.1 As -Built Total: 13158.1 CODE COMPLIANCE STATUS i BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling + Heating + Hot Water = Total Points Points Points Points 36796 10879 12300 59974 1 30306 14302 13158 57767 PASS__ EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge0D/FIaRES'2004R FLRCSB v4.5.2 FORM 60OA-2004R EnergyGauge@ 4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34963 PERMIT #: BA-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Mabmum:.3 cfm/s .ft. window area• .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. - EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1 /2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 1607.1 1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeT"" DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 87.6 The higher the score, the more efficient the home. GROZA BUILDERS, INC,- 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 1. New construction or existing New _ 2. Single family or multi -family Single family _ 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 5 5. Is this a worst case? No _ 6. Conditioned floor area (ft2) 5951 ft2 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a. (Sngle Default)1631.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 7.b. .(Tintp 631.0 ft2 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 223.0(p) ft _ b. Raised Wood, Adjacent R=11.0, 2360.OW _ c. N/A 9. Wall types a. Concrete, Ext Insul, Exterior R=8.0, 4356.0 ft2 b. Frame, Wood, Adjacent R=11.0, 460.0 ft2 _ c. Concrete, Int Insul, Adjacent R=8.0, 110.0 ft2 d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic R=30.0, 3950.0 ft2 b. N/A c. N/A _ 11. Ducts a. Sup: Con. Ret: Con. AH: Interior Sup. R=6,0, 100.0 ft2 b. 2 Others 200.0 ft _ 12. Cooling systems a. Central Unit b. Central Unit c. Central Unit 13. Heating systems a. Electric Heat Pump b. Electric Heat Pump c. Electric Heat Pump 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a P w EPL Display Card will be completed based on installed Code com li t features. Builder Signature: X 7 Date: to Address of New Home:kk po S QVY. DLLM2 City/FL Zip: Cap: 58.0 kBtu/hr SEER:15.50 _ Cap: 58.0 kBtu/hr SEER:15.50 _ Cap: 36.0 kBtu/hr SEER:18.00 Cap: 58.0 kBtu/hr HSPF:9.00 _ Cap: 58.0 kBtu/hr HSPF:9.00 Cap: 36.0 kBtu/hr HSPF: 9.00 Cap: 80.0 gallons EF: 0.86 *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStar° designation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. -Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at iviviv fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. i Predominant glass type. For actual glass type and areas see Summer & Winter Glass ouut on a es 2&4. LnergyGauge® (Version: TLRC�S$ v4.5.2) PT, S wrightsoft, Project Summary zone 1 PERFECT COOLING INC. . 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 For: GROZA BUILDERS, INC 511 S.W. PORT ST LUCIE BLVD, Phone: 772-336-7105 Notes: GROZA BUILDERS residence for: WILLIAMS ST LUCIE COUNTY Design Information Weather: Fort Pierce, FL, US LUCIE, FL 34953 Job: 06649 Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db. 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 38243 Btuh Structure 44209 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (80 cfm) 2462 Btuh Central vent (80 cfm) 1319 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 40705 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 45528 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2181 Btuh Ducts 0 Btuh Heating Cooling Central vent (80 cfm) 3342 Btuh Area (f:2) 2051 2051 Equipment latent load 5523 Btuh Volume (ft3) 20056 20056 Air changes/hour 0.29 0.16 Equipment total load 51050 Btuh Equiv. AVF (cfm) 97 52 Req. total capacity at 0.74 SHR 5.1 ton Heating Equipment,Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade Trade Model 25HNA96OA003 H FE4ANB006 Cond 25HNA96OA003 H FE4ANB006 ARI ref no. Coil ARI refrno. Efficiency 9 HSPF Efficiency 15.5 SEER Heating input Sensible cooling 43000 Btuh Heating output 57000 Btuh @ 470F Latent cooling 15000 Btuh Temperature rise 27 OF Total cooling 58000 Btuh Actual air flow 1900 cfm Actual air flow 1900 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. .—!Zn rf wrightsoft` Right -Suite® Universal 7.1.06 RSU08046 - 2009-Jun-16 22:14:06 ACCX C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GROZA\07GROZA-williams.rup Calc Page 1 0 - - wrightsoft, Project Summary zone 2 PERFECT COOLING INC. .. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 P'ro'ect 1,nf6rmation For: GROZA BUILDERS, INC 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL 34953 Phone: 772-336-7105 Notes: GROZA BUILDERS residence for: WILLIAMS ST LUCIE COUNTY ®- s errnation Weather: Fort Pierce, FL, US Job: 06649 Date: 6-30-07 By: J.S. Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 31796 Btuh Structure 41088 Btuh ' Ducts 0 Btuh Ducts 0 Btuh Central vent (106 cfm) 3250 Btuh Central vent (106 cfm) 1741 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 35047 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible'load 42829 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0, Structure 3659 Btuh Ducts 0 Btuh Heating Cooling Central vent (106 cfm) 4412 Btuh Area (ft2) 2902 2902 Equipment latent load 8072 Btuh Volume (ft3) 29020 29020 Air changes), ou, 0.25 0.13 Equipment total load 50901 Btuh Equiv. AVF (cfm) 119 64 Req. total capacity at 0.74 SHR 4.8 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade Trade Model 25HNA96OA003 H FE4ANB006 Cond 25HNA96OA003 H FE4ANB006 ARI ref no. Coil ARI ref no. Efficiency 9 HSPF Efficiency 15.5 SEER Heating input Sensible cooling 43000 Btuh Heating output 57000 Btuh @ 47°F Latent cooling 15000 Btuh Temperature rise 28 OF Total cooling 58000 Btuh Actual air flow 1869 cfm Actual air flow 1869 cfm Air flow factor 0.059 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. gjjj, - 44- wrigtttsoft, Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 ZCN C:\Documents and Settings\jspasovski\My Documents\Wdghtsoft HVAC\GROZA\07GROZA-williams.rup Calc Page 2 Pro ect Summa Job: 06649 W rightsoft- Date: 6-30-07 zone 3 By: J.S. PERFECT COOLING INC. . 1035 NW 17TH AVE. SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 Project hnformation _ . 1 For: GROZA BUILDERS, INC 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL 34953 Phone: 772-336-7105 Notes: GROZA BUILDERS residence for: WILLIAMS ST LUCIE COUNTY Deli; n° Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25507 Btuh Structure 28811 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (27 cfm) 831 Btuh Central vent (27 cfm) 445 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26338 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 29256 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 960 Btuh Ducts 0 Btuh Heating Cooling Central vent (27 cfm) 1129 Btuh Area (ft2) 998 998 Equipment latent load 2089 Btuh Volume (ft3) 6460 6460 Air changesthour 0.40 0.21 Equipment total load 31345 Btuh Equiv. AVF (cfm) 43 23 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade Trade Model 25HNA936AO03 H FE4ANF005 Cond 25HNA936AO03 H FE4ANF005 ARI ref no. Coil ARI ref no. Efficiency 9 HSPF Efficiency 18 SEER Heating input Sensible cooling 25200 Btuh Heating output 35000 Btuh @ 47°F Latent cooling 10800 Btuh Temperature rise 24 OF Total cooling 36000 Btuh Actual air flow 1311 cfm Actual air flow 1311 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.93 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -Fp- wrigfttsoft' Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 h°CC$k C:\Documents and Settings\ispasovskilMy Documents\Wrightsoft HVAC\GROZA\07GROZA-williams.rup Calc Page 3 L 06ed oleo dru swellllm-VZOUE)LO\VZOHE)\DV/\H 40s;g6u/N\s;uawnoo0 AVV\!Nsnosedsl\s6u1;;9S pue s;uawnooa\:0 90:4L:ZZ 9L-unf-60OZ 94080f1S21 90' L'L lesjanlun ®9;mS-jg61a •,g3asRy�p �M � I F 'p3 qjq r lenueW jo s;uawaim ai lie }aaw o; d03d Aq pai;i}iao }no}uud ZLL ZO£ 006L 006L (w;o)pannbainy L66E 9809 60Z44 E4Z8£ peol woa le401 0 0 %0 %0 0 0 %0 %0 speolion0 SL L66E 9909 60Z44 £4Z8E Ie3olgnS 4L 0 0 0 0 uol;nglnslpaa 0 0 0 0 JBISUBJ; ssal 0 0 0 0 peol lewawa ssa-j L66E 9909 60Zb4 £4Z8£ (EL o; 9 scull) le;o;gnS OE9 0 8LSL 4 OOLZ @@ saouellddV 0 0 0 0 OEZ @7 s;uedn000 :sule6 lewa;ul EL 0 ZS 0 L8L 0 L98 0 966Z uogelnuan woos (q uogen13W (e ZL 60EE 9069 LUSE 94ZS£ ule6/ssol adolanu3 E8E- OZS4 uolsjnoxe 03V (o 9 0 068Z 9L £0£ 0 060Z 9L £OE 00'0 ZO'8£ u SS£'L 4d;-VZZ d LOE 989 9L£ SLE 9LLL 448E 09LL 09LL 86'0 9L'Z u 9LO'O ILL-dOZ d 0 0 0 0 48 94 OS OS 99'L 06'0 u Z£0'0 PLOS-139L 0 0 0 0 0 0 0 0 0 00'0 00'0 S60'O s3051-VEL d 0 0 0 0 0 0 0 0 00'0 OD'O a 06VO 00LL 0—i 0 0 0 0 0 0 0 0 00'O 00'0 L60'0 ms0-8ZL 0 0 0 0 OZe US 0 9L L9'49 99'9E mu OLZ'L woL4-VL 0 0 0 0 0 0 0 0 00'0 00'0 mu OLZ'L woL4-VL 0 0 0 0 OZ8 US 0 9 L L9179 99'9£ mu OLZI woL4-V L 0 0 0 0 0 0 0 0 00'0 00'O mu OLZ'L woL4-VL 0 0 0 0 06 09L 09 06 OS'L 997 mu 960'0 soo9'L-V£L 0 0 0 0 bE9E ZS44 99Z 8ZL 96'6Z 99'9£ m OLZ'L Pw0L4-VL 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L woL4-VL 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L woL4-VL 0 0 0 0 LLOZ L90L 0 OE ZO'69 99'9£ m OLZI woL4-VL 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L WOW-VL 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L PwoLo-VL 0 0 0 0 699L LOLL 96 94 LL'4E 99'S£ M OLZ'L PLuoLO-VL 0 0 0 0 44£ 609 6ZZ S£6 09'L 997 m 960'0 s00S'L-VEL 0 0 0 0 644 EE9 OE SL 96'6Z 99'S£ ms OLZ'L woL4-VL 0 0 0 0 0 0 0 0 00'0 00'0 ms OLZ'L woL4-VL 0 0 0 0 SZ8 ££S 0 9L E0'99 99,9E ms OLZ'L w0L4-VL 0 0 0 0 0 0 0 0 00'0 00'O ms OLZI woL4-VL 0 0 0 0 06 09L 09 06 091 997 ms 960'0 s3051-VEL 0 0 0 0 0 0 0 0 00'0 00'0 s OLTL pwoL4-VL 0 0 0 0 0 0 0 0 00'0 00'0 s OLTL wow-VL 0 0 0 0 L6LL 4E2 OZL 09 S6'6Z 99,9E s OLZ'L wow-VL 0 0 0 0 0 0 0 0 00'0 00'0 s OLTL wow-VL 0 0 0 0 0 0 0 0 OVO 00'0 s OLZ'L WON-VL 0 0 0 0 9ZZZ 9LZZ SU 49 LC4£ 99,9E s OLZ'L PW0P-VL 0 0 0 0 6ZL E6ZL 994 OL9 OS'L 99'Z s S60'O s3041-veL 999L £SB 0 4Z EL£E LOLL 0 84 ZO'69 99,9E a OLZ'L woL4-VL 0 0 0 0 99ZL L90L Z4 OE £8'Lh 99'S£ a OLZ'L woL4-VL 0 0 0 0 0 0 0 0 00'0 00'0 a OLZ'L woL4-VL 0 0 0 0 L8L ELZ ZL 9 LZ'OE 99,9E a OLZ'L wow-VL F4 ZE9L 40£L OZ 84 L684 LL6£ ZZL W LOW 9VLZ a OL6'O q-VOL 96 OLL 49 98L L99 900L 8LE 909 OS'L 997 a 960'0 s0091-VEL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L pwoL4-VL 0 0 0 0 LL6L 9LZZ 0 49 96'6Z 99'S£ u OLZ'L PwoL4-VL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L woL4-VL 0 0 0 0 996 BELL 0 ZE 96'6Z 99'SE u OLZ'L wow-VL LL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L woL4-VL 0 0 0 0 OOL £LZ 0 9 96'6Z 99'SE u OLTL wow-VL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L woL4-VL 0 0 0 0 LL4 948 8LE OZ4 OS'L 997 u 960'0 s004'L-VEL f N 9 1000 ;eaH S/d/N ssaE) 1000 ;eaH S/d/N ssaE) 1060 ;eaH (de ,LJ/4n38) jagwnu (4n;g) (u) ja;awuad jo (4n;e) ()j) ia;awped jo (zil/4n38) peol U) eani peol (z;i) eaiV INiH jo anleA-n uogon.4suo3 Ai all O'EOE zU O'LSOZ ease woos S 4 O'ED£ X O'L i000gea4 u 9'9 u 0'9L p u 8'6 u S'LSZ suolsuewlp w008 ;461a4 6ulllao Ilem pasodx3 4 E Z Ja,(o; L auoz awsu woos L -s-r :As LO-0£-8 :a;ea 6VS90 :qor 9LL6-9LZ-L99 XBd £546-9LZ-L99:au0gd S44E£ ld 'HOV38 AVal30 ' L 311ns '3AV HILL MN SEO L 'ONI ON11000 103Al3d b auoz waysvoM ®f -wBw �:UOSI UM -9- wrightsofC Right-JO Worksheet zone 1 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 Job: 06649 Date: 8-30-07 By: J.S. 1 Room name dining pantry 2 Exposed wall 29.0 ft 0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat/coal 4 Room dimensions 1.0 x 210.0 ft 1.0 x 50.0 ft 5 Room area 210.0 ft2 50.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftz--°F) (Btuh/ftz) I or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 lA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 11 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 150 102 271 153 0 0 0 0 10A-b 0.970 a 27.16 34.01 48 20 1304 1632 0 0 0 0 1A-hlom 1.270 a 35.56 30.21 0 0 0 0 0 0 0 0 lA-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 41.83 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 140 110 293 165 0 0 0 0 1A-clomd 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 35.56 29.95 30 30 1067 899 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 29.95 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.50 0 0 0 0 0 0 0 0 1A-clomd 1.270 w 35.56 34.77 0 0 0 0 0 0 0 0 IA-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 35.56 69.02 0 0 0 0 0 0 0 0 IA-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 w 35.56 29.95 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 q 12B-0sw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 �D 11 D0 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 168-30ad 0.032 n 0.90 1.68 0 0 0 0 50 50 45 84 F 20P-11t 0.078 n 2.18 0.98 210 210 459 205 50 50 109 49 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -367 -39 Envelope loss/gain 3393 2687 154 94 12 a) Infiltration 386 ill 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 1029 0 1 315 Subtotal (lines 6 to 13) 1 3779 3827 154 409 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3779 3827 154 409 Duct loads 0% 0% 0 0 0% 0% 0 0 r,5 Total room load 3779 3827 154 409 Air required (cfm) 188 164 8 18 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. r� �- wrig3atsoiFx Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GROZA\07GROZA-WIliams.rup Calc Page 2 -9- w►rightsoft9 Right-J® Worksheet zone 1 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 Job: 06549 Date: 8-30-07 By: J.S. 1 Room name kitchen breakfast 2 Exposed wall 18.0 ft 43.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heattcool 4 Room dimensions 1.0 x 290.0 ft 1.0 x 275.0 ft 5 Room area 290.0 ftz 275.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-*F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 0 0 0 0 100 36 96 54 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-h1om 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 11 IA-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 35.56 29.95 0 0 0 0 64 0 2276 1917 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 0 0 0 0 0 0 0 0 1OA-b 0.970 a 27.16 34.01 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 30.21 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 41.83 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 180 180 479 270 140 110 293 165 1A-clomd 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 35.56 29.95 0 0 0 0 30 30 1067 899 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 0 0 0 0 45 30 80 45 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 15 0 533 825 IA-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 29.95 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.50 0 0 0 0 100 70 186 105 1A-clomd 1.270 w 35.56 34.77 0 0 0 0 0 0 0 0 IA-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hiom 1.270 w 35.56 69.02 0 0 0 0 30 0 1067 2071 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 IA-hiom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 w 35.56 29.95 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 0 0 0 0 45 30 80 45 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 15 0 533 820 1A-h1am 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 q �D 1213-0sw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 168-30ad 0.032 n 0.90 1.68 0 0 0 0 0 0 0 0 F 20P-11t 0.078 n 2.18 0.98 290 290 633 283 275 275 601 268 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -293 -79 Envelope loss/gain 1112 260 6811 7135 12 a) Infiltration 240 69 573 164 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 1 2730 0 0 Subtotal (lines 6 to 13) 1352 3059 7384 7299 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1352 3059 7384 7299 15 Duct loads 0% 0% 0 0 0% 0%1 0 0 Total room load 1352 3059 7384 7299 Air required (cfm) 67 131 367 314 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -h{a wragF�csoft Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 '� C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GROZA\07GROZA-williams.rup Calc Page 3 -+ wrightsoft' Right-JO Worksheet zone 1 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 Job: 06649 Date: 8-30-07 By: J.S. 1 Room name loft stairs 2 Exposed wall 22.0 ft 30.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 433.0 ft 1.0 x 80.0 ft 5 Room area 433.0 ft' 80.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-'F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 0 0 0 0 80 80 213 120 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 11 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 0 0 0 0 170 116 309 174 10A-b 0.970 a 27.16 34.01 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 30.21 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 41.83 0 0 0 0 30 21 1067 1255 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 24 0 853 1656 13A 7.5ocs 0.095 s 2.66 1.50 0 0 0 0 50 50 133 75 1A-clomd 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 35.56 29.95 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 IA-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 35.56 29.95 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.50 220 92 245 138 0 0 0 0 1A-clomd 1.270 w 35.56 34.77 0 0 0 0 0 0 0 0 1Aclomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 35.56 69.02 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1A-h1omd 1.270 1.270 w w 0.00 35.56 0.00 29.95 0 128 0 128 0 4552 0 3834 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 q 12B-Osw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 11D0 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 -0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 n 0.90 1.68 0 0 0 0 0 0 0 0 F 20P-11t 0.078 n 2.18 0.98 130 130 284 127 80 80 175 78 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 4374 -366 Envelope loss/gain 5080 8473 2749 2992 12 a) Infiltration 293 84 400 115 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 0 0 714 Subtotal (lines 6 to 13) 5373 8557 3149 3821 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5373 8557 3149 3821 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 5373 8557 :1 3149 3821 Air required (cfm) 267 368 156 164 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ., r}� wroghtsoft Right-Suite(g) Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 '`�� C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GROZA\07GROZA-williams.rup Calc Page 4 -1- wrightsoft' Right-JO Worksheet zone 1 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 Job: 06549 Date: 8-30-07 By: J.S. 1 Room name den den bath 2 Exposed wall 10.0 ft 18.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 105.0 ft 1.0 x 65.0 ft 5 Room area 105.0 ftz 65.0 ftz Ty Construction U-value Or HTM Area (ft) Load Area (ftz) Load number (Btuh/ftz-*F) (Btuh/ftz) I or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.Socs 0.095 n 2.66 1.50 0 0 0 0 130 124 330 186 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 n 35.56 29.95 0 0 0 0 6 0 213 180 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 11 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 100 52 138 78 50 44 117 66 10A-b 0.970 a 27.16 34.01 48 20 1304 1632 0 0 0 0 1A-hlom 1.270 a 35.56 30.21 0 0 0 0 6 6 213 181 IA-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 41.83 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 0 0 0 0 0 0 0 0 1A-clomd 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 s 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0:00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0_ 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 sw 35.56 29.95 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.50 0 0 0 0 0 0 0 0 IA-clomd 1.270 w 35.56 34.77 0 0 0 0 0 0 0 0 1A clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 35.56 69.02 0 0 0 0 0 0 0 0 IA-h1om 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 w 35.56 29.95 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 R 1213-0sw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 L-D 11DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 n 0.90 1.68 0 0 0 0 0 0 0 0 F 20P-11t 0.078 n 2.18 0.98 105 105 229 102 65 65 142 63 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -346 -65 Envelope loss/gain 1671 1467 1016 611 12 a) Infiltration 133 38 240 69 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 1 2100 0 0 Subtotal (lines 6 to 13) 1805 3605 1255 680 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1805 3605 1255 680 Duct loads 0% 0% 0 0 0% 0% 0 0 L_15 Total room load 1805 3605 1255 680 Air required (cfm) 1 190 155 1 62 29 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +°{ + wr:yt.tsoft Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 ACCk C:\Documents and Settings\jspasovsklMy Documents\Wdghtsoft HVAC\GROZA\07GROZA-williams.rup Calc Page 5 -F - wrightsoft� Right-JO Worksheet zone 1 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 Job: 06649 Date: 8-30-07 By: J.S. 1 Room name piano area 2 Exposed wall 41.5 ft 3 Ceiling height 10.0 ft heat/cool 4 Room dimensions 1.0 x 240.0 ft 5 Room area 240.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area Load number (Btuh/ft' °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs A095 n 2.66 1.50 110 78 207 117 -IA-hlom 1.270 n 0.00 0.00 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 11 G 1A-hiom 1.270 n 35.56 29.95 32 0 1138 958 1A-h1om 1.270 n 0.00 0.00 0 0 0 0 1A-hlomd 1.270 n 35.56 29.95 0 0 0 0 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 0 0 0 0 10A-b 0.970 a 27.16 34.01 0 0 0 0 1A-hlom 1.270 a 35.56 30.21 0 0 0 0 1A-hlom 1.270 a 0.00 0.00 0 0 0 0 IA-hlom 1.270 a 35.56 41.83 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 100 36 96 54 1A-clomd 1.270 s 35.56 34.77 64 64 2276 2226 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 1A-hlom 1.270 s 35.56 29.95 0 0 0 0 IA-hlom 1.270 s 0.00 0.00 0 0 0 0 IA-hlomd 1.270 s 0.00 0.00 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 45 30 80 45 1A-hiom 1 1.270 sw 0.00 0.00 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 IA-hlom 1.270 sw 35.56 29.95 15 15 533 449 13A-7.5ocs 0.095 w 2.66 1.50 115 67 178 101 1A-clomd 1.270 w 35.56 34.77 48 48 1707 1669 1A-clomd 1.270 w 0.00 0.00 0 0 0 0 IA-hlom 1.270 w 0.00 0.00 0 0 0 0 1A-hlom 1.270 w 35.56 69.02 0 0 0 0 1A-hiom 1.270 w 0.00 0.00 0 0 0 0 IA-hlom 1.270 w 0.00 0.00 0 0 0 0 IA-hlomd 1.270 w 35.56 29.95 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 45 30 80 45 ,A-hlom 1.270 nw 0.00 0.00 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 1A-h1om 1.270 nw 0.00 0.00 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 15 0 533 820 R L-D 12B-Osw 0.097 - 0.00 0.00 0 0 0 0 11DO ;0.390 a 0.00 0.00 0 0 0 0 P 13A-7.5ocs .'0.095 - 0.00 0.00 0 0 0 0 C 16B-30ad 0.032 n 0.90 1.68 0 0 0 0 F 20P-1lt 0.078 n 2.18 0.98 240 240 524 234 F 22A-tph -1.358 n 38.02 0.00 0 0 0 0 6 c) AED excursion 2084 Envelope loss/gain 7353 8802 12 a) Infiltration 553 159 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances @ 2100 0 0 Subtotal (lines 6 to 13) 7905 8961 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 7905 8961 15 Duct loads 0% 0% 0 0 Total room load 7905 8961 Air required (cfm) 1393 385 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. r}a- wragtatsoft Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 ACCA C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GROZA\07GROZA-williams.rup Calc Page 6 rF wrightsoft-, Right-J® Worksheet zone 2 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 661-276-9553 Fax 561-276-9716 Job: 06549 Date: 8-30-07 By: J.S. 1 Room name zone 2 great room 2 Exposed wall 281.5 ft 28.0 ft 3 Ceiling height 10.0 ft p 10.0 ft heat1cool 4 Room dimensions 1.0 x 600.0 ft 5 Room area 2902.0 ftz 600.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-*F) (Btuh/ftz) or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 850 779 2072 1169 210 178 473 267 1A-hlom 1.270 n 35.56 29.95 9 0 320 270 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 35.56 29.95 30 0 1067 899 0 0 0 0 11 1A-hlom 1.270 n 35.56 29.95 32 0 1138 95B 32 0 1138 958 1A-h1om 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-h1omd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 620 488 1298 732 70 55 146 83 10A-b 0.970 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 67.77 117 7 4161 7929 0 0 0 0 1A-h1om 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 15 0 533 1035 15 0 533 1035 13A-7.5ocs 0.095 s 2.66 1.50 665 569 1514 854 0 0 0 0 IA-clomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 s 35.56 29.95 6 12 213 180 0 0 0 0 1A-hlom 1.270 s 35.56 29.95 90 180 3200 2696 0 0 0 0 IA-h1om 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 90 60 160 90 0 0 0 0 1A-hlom 1.270 sw 35.56 43.60 30 27 1067 1308 0 0 0 0 1A-h1om 1,270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.50 430 308 819 462 0 0 0 0 1A-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 IA-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A hlom 1.270 w 35.56 67.77 122 8 4338 8268 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1omd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 90 60 160 90 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 30 0 1067 1640 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 q �-D 12B-Osw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 n 0.90 1.68 2902 2902 2600 4875 0 0 0 0 F 20P-11t 0.078 n 2.18 0.98 600 600 1310 585 600 600 1310 585 F 22A-tph 1.358 n 38.02 0.00 0 29 1103 0 0 0 0 0 6 c) AED excursion 3819 -117 Envelope loss/gain 28140 37860 3601 2812 12 a) Infiltration 3657 1049 373 107 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 0 0 Appliances @ 2100 0 1029 0 0 Subtotal (lines 6 to 13) 31796 41088 3974 2919 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 31796 41088 3974 2919 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 31796 41088 3974 2919 Air required (cfm) 1869 1869 234 133 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -r{+ wr:ghtsoft Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 �� C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GROZA\07GROZA-williams.rup Calc Page 7 8 86ed oleo dru'swelll.!m-VZObE)LO\VZObE)\OV/\H l;0sly6uM\s;u9wnoop fVgViMsnosedsf\s6ug;aS pue s;uawnoop\:o 90 bL:ZZ 9L-unr-60OZ 94080nSb 90' L'L lesJanlun C+9ellnS-;y61b `. 73 Me f lenueW jo s;uawaim ai lie;aaw o; VOOV Aq peggiao;no;uud 91, 9Z L4L 041, (w1o)pajlnbainV L9£ Z4Y 4ZZE 98EZ pe01 woa 18401 0 0 %0 %0 0 0 %0 %0 speollon0 SL LSE Z4b 4ZZE 98EZ Ie3o3gnS 4L 0 0 0 0 uopqulslpab 0 0 0 0 ialsueil ssal 0 0 0 0 peol lewayca seal L9E Z44 bZZE 98EZ (Cl, o; 9 saull) le;o;qnS 0 0 0 0 0 OEZ 0 I. OOLZ @7 seouellddV OEZ @ sluednoo0 :su1e6 lewa;ul EL 0 0 L9 0 SLL o 004 uopelg uan woos (q u0ge4lgul (e u6L BEE SLE 6L8Z L861, u1e6/ssoladolanu3 9 £9 uolsjnoxe a3V (0 9 0 0 0 0 0 0 0 0 00'0 WOE u 89V L 4d1-VZZ d 0 0 0 0 0 0 0 0 96'0 8VZ u 9L0'0 41,-dOZ d 48 Sb 09 09 OLE Z0Z 9ZZ SZZ STL 06'0 u ZEO'0 PeoE-89L 0 0 0 0 0 0 0 0 0 00'0 00'0 960'0 soo4'L-VEL d 0 0 0 0 0 0 0 0 00'0 00'0 a 06£'0 DOLL 0 0 0 0 0 0 0 0 00'0 00'0 - L60'0 m50-8ZL 0 0 0 0 0 0 0 0 00'0 00'0 mu OLZ'L wol4-VI 0 0 0 0 0 0 0 0 00'0 00'0 MU OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 00"0 MU OLZ'L woLy-VL 0 0 0 0 0 0 0 0 L9'44 99,9E mu OLZ'L woLy-VL 0 0 0 0 0 0 0 0 09'L 99'Z mu 960'0 S309'L-VEL 0 0 0 0 0 0 0 0 00'0 00'0 m OLT1, PwoL4-VL 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L WOW-VL 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L WOW-VL 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L woW VL 0 0 0 0 0 0 0 0 LL.19 99'9E m OLT1, WOW-Vl 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L PwoLo-VL 0 0 0 0 0 0 0 0 00'0 00'0 m OLT PwoP-VL 0 0 0 0 0 0 0 0 09'L 997 m 960'0 soo4'L-VEl 0 0 0 0 0 0 0 0 00'0 00'0 ms OLZ3 woLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 ms OLZ'L woLy-yl 0 0 0 0 0 0 0 0 00'0 00'0 ms OLZ'L woLy-VL 0 0 0 0 0 0 0 0 09'E4 95,9E Ms OLZ'L woLy-VL 0 0 0 0 0 0 0 0 09'I. 997 ms 960'0 s3051-VEL 0 0 0 0 0 0 0 0 00'0 00'0 s OLZ'L PwoW-VL 0 0 0 0 0 0 0 0 00'0 00'0 s OLZ'L w0W-VL 0 0 0 0 0 0 0 0 00'0 00'0 s OLZ"L woLy-VL 0 0 0 0 0 0 0 0 96'6Z 99'SE s OLZ' L WOW -VI, 0 0 0 0 0 0 0 0 96'6Z 99'SE s OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 s OLZ'L PwOW-VL 0 0 0 0 0 0 0 0 OS•L 99'Z s 960'0 S3091-VEL 0 0 0 0 0 0 0 0 ZO'69 99'9E a OLZ'L wQl4-VL 0 0 0 0 0 0 0 0 00'0 00'0 a OLZ'L woW VL 0 0 0 0 E£OZ L90L L OE LL'L9 99,9E a OLZ'L wol,4-VL 0 0 0 0 0 0 0 0 00'0 00'0 a OLZ'L woLwvV 0 0 0 0 0 0 0 0 00'0 00'0 a OL6'0 q-VOL 0 0 0 0 96 L 9t4E OE L 09 L OS' I. 99'Z a 960'0 s0051-VE L 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L PwoLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 u OLT1, PwoLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L woW-VL 0 0 0 0 0 0 0 0 96'6Z 99'9E u OLZ'L w0W-VL LL 0 0 0 0 0 0 0 .0 96'6Z 99'9£ u OLZ'L woW-VL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L w0W-VL 08L £LZ 0 9 0 0 0 0 96'6Z 99,9E u OLTL woLy-VL 99 LLL 4b OS OLZ ZL£ 041, 0114 OS'L 99'Z u 960'0 S0091-VEL m 9 loo0 189H S/d/N ssa0 1000 ;eaH S/d/N ssa0 1000 leaH (do z)l/4n18) jagwnu (4n19) (u) ja;awuad jo (qn;g) (u) ja;awuad jo (z8/4n;e) peol (z11) eaiv PeOI (z1i) eaiV VUH J0 amen-n uol;onj;suo3 /1 Eli 0'09 z14 0'9ZZ ease wood S 11 0'09 x 0'L u O'SZZ x O'L suolsuawlp W008 b 1000peaq 7u TO L 1000pea4 u 0'01, 1461eq 6ulllao E 11 0'9 11 0'0E Ilem pas0dx3 Z £ yleq £ woapaq aweu wood L -s-r :As LO-09-8 :01ea 6VS90 :qor 9LL6-9LZ-W9 xed £9S6-9LZ-L99 :auoyd S44£E ld 'HOV39 kVbl34 ' L 31InS '3AV H-LLL MN S£OL ON[ ON11003 133=INBd Z auoz wa4svoM ®f -446!2i �1os}y6�.,�u► -q- wrightsoft3 Right-J® Worksheet zone 2 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 Job: 06549 Date: 8-30-07 By: J.S. 1 Room name cl 3 play room 2 Exposed wall 0 ft 11.0 ft 3 Ceiling height 10.0 ft heaUcool 10.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 ft 1.0 x 90.0 ft 5 Room area 50.0 ftz 90.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 11 1A-hiom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hiomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 0 0 0 0 80 50 133 75 10A-b 0.970 a 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 67.77 0 0 0 0 30 1 1067 2033 1A-h1om 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 0 0 0 0 25 25 66 38 1A-clomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 35.56 29.95 0 0 0 0 0 0 0 0 1A hlom 1.270 s 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 43.60 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 13A-7.5ocs 1.270 0.095 sw. w 0.00 2.66 0.00 1.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 IA-clomd 1A-hiom 1A-hlom 1.270 1.270 1.270 w w w 0.00 35.56 0.00 0.00 67.77 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IA-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A hlomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 q 1213-0sw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 �D 11DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 n 0.90 1.68 50 50 45 84 90 90 81 151 F 20P-1lt 0.078 n 2.18 0.98 0 0 0 0 0 0 0 0 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -8 43 Envelope loss/gain 45 76 1347 2340 12 a) Infiltration 0 0 140 40 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 0 0 1 1029 Subtotal (lines 6 to 13) 45 76 1487 3409 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 45 76 1487 3409 15 Duct loads 1 0% 0% 0 0 0% 0% 0 0 Total room load I 45 76 1487 3409 Air required (cfm) I 13 3 1 87 155 Printout certified by ACCA to meet all requirements of Manual J Sth Ed. r} r wr:ghtsofc Right -Suite@ Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 Ck C:\Documents and Settings\jspasovski\My Documents\Wdghtsoft HVAC\GROZA\07GROZA-vuilliams.rup Cale Page 9 06649 -r- wrightsoW Right-JO Worksheet Job: Date: 8-30--30- 07 zone 2 By: J.S. PERFECT COOLING INC. 1035 NW 17TH AVE. SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 1 Room name bedroom 4 bath 4 2 Exposed wall 31.0 It 0 ft 3 Ceiling height 10.0 ft heattcool 10.0 ft heat/cool 4 Room dimensions 1.0 x 240.0 ft 1.0 x 60.0 ft 5 Room area 240.0 ftz 60.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-*F) (Btuh/ftz) or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-h1om 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 11 1A-h1om 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 IA-h1om 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-h1omd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 150 120 319 180 0 0 0 0 1OA-b 0.970 a 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 67.77 30 1 1067 2033 0 0 0 0 1A-h1om 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 160 160 426 240 0 0 0 0 1A-clomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 s 35.56 29.95 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 35.56 29.95 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 0 0 0 0 0 0 0 0 IA-hlom 1.270 sw 35.56 43.60 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.50 0 0 0 0 0 0 0 0 1Aclomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 w 35.56 67.77 0 0 0 0 0 0 0 0 1A hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1omd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw, 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw, 0.00 0.00 0 0 0 0 0 0 0 0 12B-Osw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 11130 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 n 0.90 1.68 240 240 215 403 60 60 54 101 F 20P-11t 0.078 n 2.18 0.98 0 0 0 0 0 0 0 0 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 59 -10 Envelope loss/gain 2027 2915 54 91 12 a) Infiltration 413 119 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 2100 0 1 0 0 0 Subtotal (lines 6 to 13) 2440 3264 54 91 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2440 3264 54 91 15 Duct loads 1 0% 0% 0 0 0% 0%1 0 0 Total room load 2440 3264 54 91 Air required (cfm) 143 148 3 4 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +{=t wr��htsofz Right -Suite@ Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 Ct� C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GROZA\07GROZA-Mlliams.rup Calc Page 10 -1 - wrightsoft! Right-J® Worksheet zone 2 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 Job: 06649 Date: 6-30-07 By: J.S. 1 Room name master bath master toilet 2 Exposed wall 12.0 ft 0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 80.0 ft 1.0 x 30.0 It 5 Room area 80.0 ft' 30.0 ft' Ty Construction U-value Or HTM Area (ft) Load Area (ftz) Load number (Btuh/W--'F) (Btuh/ft') or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 11 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 0 0 0 0 0 0 0 0 1OA-b 0.970 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 67.77 0 0 0 .0 0 0 0 0 1A-h1om 1A-hlom 1.270 1.270 a a 0.00 35.56 0.00 69.02 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 80 65 173 98 0 0 0 0 1A-clomd IA-hlom 1.270 1.270 s s 0.00 35.56 0.00 29.95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 35.56 29.95 15 15 533 449 0 0 0 0 1A-hlom 1A-h1om 1.270 1.270 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-h1omd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs IA-hlom 0.095 1.270 sw sw 2.66 35.56 1.50 43.60 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-hlom 1A-h1om 1.270 1.270 sw sw 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A hlom 13A-7.5ocs 1A-clomd 1.270 0.095 1.270 sw w w 0.00 2.66 0.00 0.00 1.50 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1Aclomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1A-h1om 1.270 1.270 w w 35.56 0.00 67.77 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A hlom 1.270 w 0.00 0.00 0 0 0 0 O 0 0 0 IA-hlom 1A-h1omd 1.270 1.270 w w 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-7.5ocs 1A-h1om 0.095 1.270 nw nw 2.66 35.56 1.50 54.67 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-hiom 1A-hlom 1.270 1.270 nw nw 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 R 12B-Osw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 L--D 11 DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C F 16B-30ad 20P-11t 0.032 0.078 n n 0.90 2.18 1.68 0.98 80 0 80 0 72 0 134 0 30 0 30 0 27 0 50 0 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 35 -5 Envelope loss/gain 778 716 27 45 12 a) Infiltration 107 31 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 0 0 0 Subtotal (lines 6 to 13) 885 747 1 27 45 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 885 747 27 45 15 Duct loads 0% 0% 0 0 0% 0%1 0 0 Total room load 885 747 27 45 Air required (cfm) 152 34 2 2 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. t { e- wraghssors Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 MCA C:\Documents and Settings\jspasovski\My Documents\Wdghtsoft HVAC\GROZA\07GROZA-vAlliams.rup Calc Page 11 -r- wrightsoft; Right-JO Worksheet zone 2 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276.9553 Fax 561-276-9716 Job: 06649 Date: 8-30-07 By: J.S. 1 Room name master bath 1 master bedroom 2 Exposed wall 12.0 ft 35.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heattcool 4 Room dimensions 1.0 x 80.0 ft 1.0 x 310.0 ft 5 Room area 80.0 ft2 310.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-*F) (Btuh/ft2) or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 11 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1omd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 0 0 0 0 0 0 0 0 1OA-b 0.970 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 67.77 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 120 114 303 171 160 115 306 173 1A-clomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 s 35.56 29.95 6 6 213 180 0 0 0 0 1A-h1om .1.270 s 35.56 29.95 0 0 0 0 45 45 1600 1348 1A-h1om 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 0 0 0 0 45 30 80 45 1A-h1om 1.270 sw 35.56 43.60 0 0 0 0 15 7 533 654 IA-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.50 0 0 0 0 100 70 186 105 IA-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 35.56 67.77 0 0 0 0 30 1 1067 2033 IA-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hiom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 0 0 0 0 45 30 80 45 ,A-hlom 1.270 nw 35.56 54.67 0 0 0 0 15 0 533 820 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw, 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 R 12B-Osw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 L-D 11DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-30ad 40.032 n 0.90 1.68 80 80 72 134 310 310 278 521 F 20P-11t 0.078 n 2.18 0.98 0 0 0 0 0 0 0 0 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -10 1295 Envelope loss/gain 588 475 4663 7038 12 a) Infiltration 160 46 466 134 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances @ 2100 0 01 0 0 Subtotal (lines 6 to 13) 748 521 5129 7632 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 748 521 5129 7632 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 748 521 1 5129 7632 Air required (cfm) 1 144 24 302 1 347 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -+ + wrJghtsott Right -Suite@ Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 �� C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GROZA\07GROZA-williams.rup Calc Page 12 06549 - - Job: wrightsoft, Right-JO Worksheet 8-30- zone 2 Date: -30-07 By: J.S. PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 1 Room name master cl her master cl his 2 Exposed wall O ft O ft 3 Ceiling height 10.0 ft heat(cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 70.0 ft 1.0 x 50.0 ft 5 Room area 70.0 ftz 50.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz--°F) (Btuh/ftz) I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 0 0 0 0 0 0 0 0 1A-h1om 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-h1om 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1lom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 11 1A-hlom 1,.270 n 35.56 29.95 0 0 0 0 0 0 0 0 G 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1omd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1omd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 0 0 0 0 0 0 0 0 1OA-b 0.970 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 67.77 0 0 0 0 0 0 0, 0 1A-h1om 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 0 0 0 0 0 0 0 0 1Aclomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 35.56 29.95 0 0 0 0 0 0 0 0 1A-h1om 1.270 s 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1cm 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 0 0 0 0 0 0 0 0 IA-h1om 1.270 sw 35.56 43.60 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1lom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.50 0 0 0 0 0 0 0 0 IA-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 IA-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 w 35.56 67.77 0 0 0 0 0 0 0 0 1A hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 q 1213-0sw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 �-D 11 DO 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 n 0.90 1.68 70 70 63 118 50 50 45 84 F 20P-11t 0.078 n 2.18 0.98 0 0 0 0 0 0 0 0 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -11 -8 Envelope loss/gain 63 106 45 76 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 0 0 0 Subtotal (lines 6 to 13) 63 106 45 76 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 63 106 45 76 15 Duct loads 1 0% 0% 0 0 0% 0%1 0 0 Total room load 63 106 45 76 Air required (cfm) 4 5 3 3 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -f+ wr:ghtsota Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 ACCk C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GR0ZA\07GR0ZA-williams.rup Calc Page 13 -9- wrightsoft° Right-J® Worksheet zone 2 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276.9553 Fax 561-276-9716 Job: 06549 Date: 8-30-07 By: J.S. 1 Room name guest room guest bath 2 Exposed wall 46.0 ft 9.0 ft 3 Ceiling height 10.0 ft heat/ccol 10.0 ft heaUcool 4 Room dimensions 1.0 x 256.0 ft 1.0 x 80.0 ft 5 Room area 256.0 ftz 80.0 ftz Ty Construction U-value Or HTM Area (ft) Load Area (ft2) Load number (Btuh/ft?'F) (Btuhfftz) or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Coal Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 140 140 372 210 90 87 231 131 IA-hlom 1.270 n 35.56 29.95 0 0 0 0 3 0 107 90 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 11 G 1A hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 0 0 0 0 0 0 0 0 10A-b 1A-hlom 1A-h1om 0.970 1.270 1.270 a a a 0.00 0.00 35.56 0.00 0.00 67.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-h1om 1A-hlom 1.270 1.270 a a 0.00 35.56 0.00 69.02 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 120 90 239 135 0 0 0 0 1A-clomd 1A-hlom 1.270 1.270 s s 0.00 35.56 0.00 29.95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-hlom 1A-hlom 1A-h1om 1.270 1.270 1.270 s s s 35.56 0.00 0.00 29.95 0.00 0.00 30 0 0 30 0 0 1067 0 0 899 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs ,A-hlom 0.095 1.270 sw sw 2.66 35.56 1.50 43.60 45 15 30 7 80 533 45 654 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 IA-h1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 13A-7.5ocs 1A-clomd 1.270 0.095 1.270 sw w w 0.00 2.66 0.00 0.00 1.50 0.00 0 110 0 0 78 0 0 207 0 0 117 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-clomd IA-hlom 1A hlom 1.270 1.270 1.270 w w w 0.00 35.56 0.00 0.00 67.77 0.00 0 32 0 0 1 0 0 1138 0 0 2169 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-h1om 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1A-hlomd 1.270 1.270 w w 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-7.5ocs ,A-hlom 0.095 1.270 nw nw 2.66 35.56 1.50 54.67 45 15 30 0 80 533 45 820 0 0 0 0 0 0 0 0 1A-hlom 1A-hlom 1.270 1.270 nw nw 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1213-0sw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 1-0 11D0 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 n 0.90 1.68 256 256 229 430 80 80 72 134 F 20P-11t 0.078 n 2.18 0.98 0 0 0 0 0 0 0 0 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 1329 -17 Envelope loss/gain 4480 6853 410 338 12 a) Infiltration 613 176 120 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 2100 0 0 0 0 Subtotal (lines 6 to 13) 5093 7259 530 372 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5093 7259 530 372 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 5093 7259 530 372 Air. required (cfm) 299 330 31 17 Printout certified by ACCA to meet all requirements of Manual J Sth Ed. tr wragtissott Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GROZA\07GROZA-vrilliams.rup Cale Page 14 -- wrightsoft, Right-J® Worksheet zone 2 PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 Job: 06549 Date: 8-30-07 By: J.S. 1 Room name guest cl stairs 3 2 Exposed wall 0 ft 11.5 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 70.0 ft 1.0 x 150.0 ft 5 Room area 70.0 ftz 150.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 11 1A-hlom 1.270 n 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 a 2.66 1.50 0 0 0 0 90 78 207 117 10A-b 0.970 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 67.77 0 0 0 0 12 0 427 813 IA-hiom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 IA-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 0 0 0 0 0 0 0 0 1A-clomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 35.56 29.95 0 0 0 0 0 0 0 0 1A-h1om 1.270 s 35.56 29.95 0 0 0 0 0 0 0 0 1A-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 35.56 43.60 0 0 0 0 0 0 0 0 IA-h1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.50 0 0 0 0 0 0 0 0 1A-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A hlom 1.270 w 35.56 67.77 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1omd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 0 0 0 0 0 0 0 0 1A-hiom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 q 1213-0sw 0.097 - 0.00 0.00 0 0 0 0 0 0 0 0 �-D 1100 0.390 a 0.00 0.00 0 0 0 0 0 0 0 0 P 13A-7.5ocs 0.095 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 n 0.90 1.68 70 70 63 118 150 150 134 252 F 20P-11t 0.078 n 2.18 0.98 0 0 0 0 0 0 0 0 F 22A-tph 1.358 n 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 11 30 Envelope loss/gain 63 106 769 1212 12 a) Infiltration 0 0 120 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 0 0 1 0 Subtotal (lines 6 to 13) 63 106 888 1247 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 63 106 888 1247 15 Duct loads 1 0% 0% 0 0 0% 0% 0 0 Total room load 63 106 888 1247 Air required (cfm) 4 5 52 1 57 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +} i- wr:ytasoi7c Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 �� C:\Documents and Settings\jspasovski\My Documents\Wrightsoft HVAC\GROZA\07GROZA-vrilliams.nip Calc Page 15 9L 86ed oleo dru swelll!m-VZObE)LO\VZOaEJ\OVAH;;os3U6uM\sluawnoo0 AV4V1 lsnosedsl\s6u!llaS pue sluawnoo0\:0 10CW 90:4L:ZZ 9L-unr-60OZ 94080r1sH 90'L'L Iesjanlun ®al!nS-1y6la .13osSyBl+ty� f I'� k p� M8 r lenueW }o s;uawaim ai Ile }aaw of dOOd Aq paigpeo;nopid 914 Z9Z £6Z 68L (w;o)pajlnbaij1V 96LE 8LZ4 L449 LZZE peol wow Ielo1 0 0 %0 %0 0 0 %0 %0 speolLon0 9L 86L£ 8LZ4 L"9 LZZE Ie3o;gnS 4L 0 0 0 0 uogngl4slpaa 0 0 0 0 Ja;sued ssel 0 0 0 0 peol lewayca ssal 86L£ 8LZ4 L449 LZZE (£L o; 9 sau!1) Ie3o3gnS 0 0 0 0 OOLZ @ seouellddV 0 0 0 0 OEZ i]o swedn000 :sule6lewalul EL 0 0 0 0 uo!;el4uan woos (q LLL 99£ 48 E6Z uo9eJ31Jul (e ZL L90£ Z69E LSE9 LZ6Z u1e6/ssol adolanu3 bOZ- 09EL uolsmoxe 03V (0 9 0 EOL L 6Z 0 0 0 0 0 00'0 ZO'9E u 89E" L 4dl-VZZ d 0 0 0 0 0 0 0 0 96'0 .9L'Z u 8LO'O 4L-dOZ d goo 9Es 009 009 069 89E M? M, 99'L 06'0 u Z£0'0 PLOC-89L O 0 0 0 0 0 0 0 0 00'O 00'0 960'0 s0091-VCL d 0 0 0 0 0 0 0 0 00'0 00'0 a 06VO OOLL 0— 0 0 0 0 0 0 0 0 00'0 00'0 L60'O mso-8ZL FJ 0 0 0 0 0 0 0 0 00'0 00'0 mu OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 mu OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 mu OLZ'L woLy-VL 0 0 0 0 0 0 0 0 L9179 99,9E mu OLZ'L woLy-VL 0 0 0 0 0 0 0 0 09'L 99'Z mu 960'0 soos'L-V£L 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L PWON-VL 0 0 0 0 0 0 0 0 00'0 00'O m OLZ'L wOL4-VL 0 0 0 0 0 0 0 0 00'O 00'0 m OLZ'L WOLWL 0 0 0 0 0 0 0 0 00'0 00'O m OLZ'L woLU-VL 0 0 0 0 990h bELZ Z 09 LL19 99,9E m OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L PwotO-VL 0 0 0 0 0 0 0 0 00'0 00'0 m OLZ'L Pwoto-VL 0 0 0 0 04Z 9Z4 09L OZZ 09'L 99'Z m 960'0 sOOS'L-VEL 0 0 0 0 0 0 0 0 00'0 00'0 ms OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 ms OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 ms OLZ'L WOW-VL 0 0 0 0 0 0 0 0 09'£4 99'sE MS OLZ'L woL4-VL 0 0 0 0 0 0 0 0 09'L 997 ms 960'0 S0091-V£L 0 0 0 0 0 0 0 0 00'0 00'0 s OLTL PwON-VL 0 0 0 0 0 0 0 0 00'0 00'0 s OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 00'O s OLZ'L woLy-VL 0 0 0 0 0 0 0 0 96'6Z 99,9E s OLZ'L woLq-Vl 0 0 0 0 0 0 0 0 96'6Z 99,9E s OLZ'L woLy-VL Er— a 0 0 0 0 0 0 0 00'0 00'0 s OLZ'L Pwoto-VL 0 0 0 0 0 0 0 0 09'L 997 s 960'0 soos'L-VEL 0 0 0 0 0 0 0 0 ZO'69 99,9E a OLZ'L woLy-VL 0-1 0 0 0 0 0 0 0 0 00'0 00'0 a OLZ'L woLy-VL LLOL ££s 0 9L 0 0 0 0 LL'L9 99,9E a OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'O 00'0 a OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 a OL6'O q-VoL EB 94L 99 OL 0 0 0 0 09'L 99'Z a 960'0 s009'L-VEL 0 0 0 0 0 0 0 0 00"0 OTO u OLZ'L PwoLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L PwoLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L woL4-VL 0 0 0 0 0 0 0 0 96'6Z 99's£ u OLZ'L woL4-VL LL 669 L90L 0 DE 0 0 0 0 96'6Z 99,9E u OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 DOT u OLZ'L WON-VL 0 .0 0 0 0 0 0 0 96'6Z 99,5E u OLTL woL4-VL 99Z 909 06L OZZ 0 0 0 0 09'L 997 u 960'0 S0091-VEL 9 1000 leaH S/d/N sswE) 1000 ;eaH S/d/N sswE) 1000 ;eaH (do ill/4n38) jagwnu (4n18) (1;) jejewuad jo (gn38) ()j) ja;ewuad jo (,Wgnle) PLOT W) eeiv PeOI Gu) eeiv W1H JO amen-n uo!;0n4suoo Al zu 0 zu 0' L L4 ease wood 9 4 0 x 0 1000peaq U O'OL 31 0'6Z 3J O'LLb x O'L I000ABeq 4 VOL u O'ZZ suo!suaw!p woos 3461aq 6ulpeo Ilem pasodx3 4 E Z Z wow leaJ6 E 3l01 aweu woos L 9LL6-9LZ-L99 xed E996.9LZ-L99 :auoyd S44EE 13 'HOV38 AV2l130 'L 311ns '3AV HILL MN SEOL 'ONI JNI-1000 103:AN3d •sr :�8 Lo-oc-s :wa Z GUOZ sysso :Or zaaysmaoM ,UOs4461JM . -�- wrightsoft, Right-JO Worksheet Job: 06649 zone 3 Date: 5-30-07 By: J.S. PERFECT COOLING INC. 1035 NW 17TH AVE, SUITE 1, DELRAY BEACH, FL 33445 Phone: 561-276-9553 Fax 561-276-9716 1 Room name zone 3 LEFT WING 2 Exposed wall 118.0 ft 49.0 ft 3 Ceiling height 6.5 ft d 8.5 ft heat/cool 4 Room dimensions 1.0 x 380.0 ft 5 Room area 998.0 ft2 380.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-7.5ocs 0.095 n 2.66 1.50 233 147 391 221 80 24 64 36 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 11 1A-h1om 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 n 35.56 29.95 30 0 1067 899 0 0 0 0 1A-hlomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 35.56 26.96 56 0 1991 1510 56 0 1991 1510 13A-7.5ocs 0.095 a 0.00 0.00 0 0 0 0 0 0 0 0 10A-b 0.970 a 0.00 0.00 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 s 2.66 1.50 255 169 450 254 170 140 372 210 1A-clomd 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 IA-h1om 1A-hlom 1.270 1.270 s s 0.00 35.56 0.00 28.89 0 30 0 0 0 1067 0 867 0 30 0 0 0 1067 0 867 IA-hlomd 1.270 s 35.56 26.96 56 112 1991 1510 0 0 0 0 13A-7.5ocs 0.095 sw 2.66 1.50 72 42 112 63 36 21 56 32 ,A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 30 0 1067 1651 15 0 533 825 IA-hlom 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 w 2.66 1.50 357 159 423 239 85 55 146 83 1A-clomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1Aclomd 1.270 w 35.56 31.30 56 112 1991 1753 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 35.56 69.02 30 0 1067 2071 30 0 1067 2071 IA-hlom 1.270 w 35.56 26.96 112 224 3983 3019 0 0 0 0 1A-hlomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 13A-7.5ocs 0.095 nw 2.66 1.50 74 44 117 66 38 23 61 35 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 30 0 1067 1640 15 0 533 820 1A-hlom 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 R 12B-Osw 0.097 - 2.72 1.57 504 460 1249 723 128 128 348 201 �D 11DO 0.390 a 10.92 11.31 44 44 480 498 0 0 0 0 P 13A-7.5ocs 0.095 - 2.66 0.86 110 110 293 95 110 110 293 95 C 16B-30ad 0.032 n 0.90 1.68 998 998 894 1677 380 380 340 638 F 20P-11t 0.078 n 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tph 1.358 n 38.02 0.00 998 118 4487 0 380 49 1863 0 6 c) AED excursion 7605 735 Envelope loss/gain 24187 26357 8735 8157 12 a) Infiltration 1320 379 545 156 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 1 2075 0 1029 Subtotal (lines 6 to 13) 25507 28811 1 9280 9342 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 25507 28811 9280 9342 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 25507 28811 9280 9342 Air required (cfm) 1311 1311 477 425 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -r{ a wr��ntsofc Right -Suite® Universal 7.1.06 RSU08046 2009-Jun-16 22:14:06 stCCA C:\Documents and Settings\jspasovski\My Documents\Wdghtsoft HVAC\GROZM07GROZA-williams.rup Calc Page 17 8L abed op0 dru'swe!ll!m-VZONEJLO\VZ02i0\OV/\H uosLy6uM\sluawnoo0 AV4!�snosedsf\s6u!;LaS pue s;uawnooO\:0 � 90:7L:ZZ 9L-unf -60OZ 9408onsb 9o' L'L lesJan!uO ®aj!nS-;y6!a P� 4j8 p lenuew jo sluewaim ai Ile jeew o} VD:Dy Aq pailpeo }no}uud 6LE SZE L09 609 (w;o) paj!nbai ny LZ£8 L££9 ZKLL 9686 peo! w00i !e;ol 0 0 %0 %0 0 0 %0 %0 speol;on0 SL LZE8 LEES Z14LL 9686 !elo3gnS 7L 0 0 0 0 uognq!-4s!paa 0 0 0 0 Ja;suej; ssal 0 0 0 0 peo1 iewaPxa ssal LZE8 M:9 ZK L L 9686 (EL of 9 sau!!) !e;o;qnS 0 0 940E 0 OOLZ @@saoue!!ddV 0 0 0 0 OEZ @@ s;uedn000 :su!e6 !ewa;ul EL 0 0 0 0 uo!;e!nuan woos (q LL 67Z L9L 9ZS u01wAigul (e ZL 99Z8 Z809 5766 69E6 u!e8/ssol ado!anu3 ZL07 899Z uo!sjnoxe 03V (o 9 0 LES ZZ BEZ 0 LOLL L7 09£ 00*0 Zo'8£ u SSE' L 4dl-VZZ d 0 0 0 0 0 0 0 0 00'0 00'0 u OLO'O ILL-dOZ 3 coil ELZ 9£Z 8EZ RES 07E ME 08£ 89'L 06'0 u ZEO'0 pe0£-a9L 0 0 0 0 0 0 0 0 0 98'0 99'Z - 960'0 S0091-VEL d 867 097 77 77 0 0 0 0 L£' L L Z6'O L a 06VO OO L L O—� KZ 69E 9EL 08L 80E US 96L 96L L9'L ZL'Z - L60'0 msc-8ZL ki 0 0 0 0 0 0 0 0 00'o 00'0 MU OLZ'L w0L4-VL 0 0 0 0 ON EES 0 SL L9'79 99,9E mu OLZ'L wow VL 0 0 0 0 0 0 0 0 00,0 00'0 mu OLZ'L WOW-VL 0 0 0 0 0 0 0 0 00'0 00'0 mu OLZ'L WON-VL 0 0 0 0 ZE 94 LZ 9E 09'L 997 mu 960'0 S0091-V£L 0 0 0 0 0 0 0 0 00*0 OO'0 m OLZ'L PwoLy-VL 6LOE E96E ZLL ZLL 0 0 0 0 96'9Z 94,9E m OLZ'L wow-VL 0 0 0 0 0 0 0 0 ZO'69 94,9E m OLTL WON-VL 0 0 0 0 0 0 0 0 00'0 00'O m OLZ'L w0L4-VL 0 0 0 0 0 0 0 0 00'0 OO'O m OLZ'L WON-VL 0 0 0 0 ESLL L66L 94 99 OE'LE 99'SE m OLTL PWOP-VL 0 0 0 0 0 0 0 0 00'0 OO'0 m OLT PWOLO-VL ELL 66L SL LOL 77 LL 6Z 98 09'L 997 m 960'0 S0041-VEL 0 0 0 .0 0 0 0 0 Oo'0 00'O ms OLZ'L woLy-yL 0 0 0 0 SZ8 US 0 SL E0'99 99,9E ms OLZ'L wo!.4-yI 0 0 0 0 0 0 0 0 00'O 00'0 /As OLZ'L WOW-VL 0 0 0 0 0 0 0 0 00'0 00'O MS OLZ'L WON-VL 0 0 0 0 Z£ 99 LZ 9E 09'L 997 ms 460'0 S009'L-V£L 0 0 0 0 ML L66L 99 99 96'9Z 95,9E s OLZ'L PwoLy-VL 0 0 0 0 0 0 0 0 68'8Z 94,4E s OLTL wow-VL 0 0 0 0 0 0 0 0 00'0 00'0 s OLZ'L wow-VL 0 0 0 0 0 0 0 0 00'0 00'O s OLT UIOW-VL 0 0 0 0 0 0 0 0 00*0 OTT s OLZ'L WON-VL 0 0 0 0 0 O 0 0 00'O c0'0 S OLZ'L Pw0L0-VL 0 0 0 0 77 LL 6Z 98 09'L 99"Z s 960'0 Soog-L-VEL 0 0 0 0 0 0 0 0 OTO 00'0 a OL2:1 woLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 a OLZ'L WM VL 0 0 0 0 0 0 0 0 00'0 OO'0 a OLZ'L woLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 a OLZ'L woLy-VL�q 0 0 0 0 0 0 0 0 00'0 00'0 a OL6'0 g VOL 0 0 0 0 0 0 0 0 00'0 00'0 a 960'0 s00S'L VEL 0 0 0 0 0 0 0 0 96'9Z 94'SE u OLZ'L PwoLy-VL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L PWON-VL 0 0 0 0 668 L90L 0 OE 46'6Z 99'9E u OLZ'L WOW-VL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L WON-VL 0LL 0 0 0 0 0 0 0 0 00'O 00'0 u oLZ'L I wo44-VL 0 0 0 0 0 0 0 0 00'0 00'0 u OLZ'L wow-VL 0 0 0 0 0 0 0 0 00'0 00'o u OLZ'L , WOW-VL 0 0 0 0 98 L LZE EZ L ESL 091 99'Z u 960'0 S004'L-V£ L m 9 1000 ;eaH S/d/N ssa0 1000 ;eaH S/d/N ssa0 1000 ;eaH (de ru/4n;g) jagwnu (yn;g) (u) ja;awuad jo (yn;g) (u) ja;awuad jo (zu/4nlg) peol (zu) eaiV peOl (:u) eaiV W1H JO en!en-n uogonilsuoO Al zu O'9EZ Zu 0,08E ease woos 9 u 0'9£Z x 0' L 1000peay u 0 u 0'ZZ u 0,08E x 0' L 1000peay u 9'8 u 0'L7 suo!suew!p wood I46194 bu!!!a0 !!em p9s0dx3 7 E Z a31N30 ONIM 1HON aweu wood L -s-r :As LO-OE-8 :a;ea 6V99O :qor 9 LL6-9LZ-L99 xed E996-9LZ-L99:au04d S77EE ld 'HOV38 AVal3O ' L 31U1S '3/\V H1LL MN SEO L 'ONI ONI1000 103d213d E auoz iaaysiaoM ®f -}yCiN :Ums4451JM . m i FORM 60OA-2004R EnergyGauge® 4.5 FLORIDA ENERGY EFFICIENCY CODE• FOR BUILDING CONSTRUCTION Florida Department of Community Affairs " - Residential Whole Buildin4 Performance Method A r Project Name: 07GROZA-williams Builder: R DERS Address: 511 S.W. PORT ST LUCIE BLVD Permitti et U - City, State: PORT ST LUCIE, FL 34953 Permit N m Owner: GROZA BUILDERS, INC Jurisdiction Number: 661000 Climate Zone: Central 1. New construction or existing New 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 _ 4. - Number of Bedrooms 5 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ft') 5951 ft' _ 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default)[631.0 ft' _ b. SHGC: (or Clear or Tint DEFAULT) 7b. (Tint)[631.0 ft' 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 223.0(p) ft _ b. Raised Wood, Adjacent R=11.0, 2360.Oft' _ c. N/A 9. Wall types a. Concrete, Ext Insul, Exterior R=4.1, 4356.0 ft' b. Frame, Wood, Adjacent R=11.0, 460.0 ft' _ c. Concrete, Int Insul, Adjacent R=4.1, 110.0 ft' _ d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic R=30.0, 3950.0 ft' b. N/A _ c. N/A 11. Ducts _ a. Sup: Con. Ret: Con. AH: Interior Sup. R=6.0, 100.0 ft' b. 2 Others 200.0 ft 12. Cooling systems a. Central Unit b. Central Unit c. Central Unit 13. Heating systems a. Electric Heat Pump b. Electric Heat Pump c. Electric Heat Pump 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.27 Total as -built points: 59919 PASS Total base points: 59974 I hereby certify that the plans and specifi ations covered by this calculation are in c ance a Fir nergy Code. PREPARED BY: DATE: Z"-3 0-07 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. OWNER/AGE T: BUILDING OFFICIAL: _ DATE: l DATE: 1 Predominant gl ss ty e. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge@ (Version: FLRCSB v4.5) Cap: 58.0 kBtu/hr _ SEER:15.50 _ Cap: 58.0 kBtu/hr _ SEER.15.50 _ Cap: 36.0 kBtu/hr SEER 18.00 Cap: 58.0 kBtu/hr HSPF:9.00 _ Cap: 58.0 kBtu/hr _ HSPF:9.00 _ Cap: 36.0 kBtu/hr HSPF: 9.00 Cap: 80.0 gallons _ EF: 0.86 PT, Ener Gau FORM 600A-2004R 9Y e@ 4.5 9 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 PERMIT #: BASE I AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Floor Area Type/SC Overhang Ornt Len Hgt Area X SPM X SOF = Points .18 5951.0 24.35 26083.0 1.Single, Tint E 2.0 21.0 63.0 53.27 0.99 3337.0 2.Single, Tint E 6.5 10.0 144.0 53.27 0.65 4999.0 3.Single, Tint S 2.0 18.0 60.0 39.84 0.99 2364.0 4.Single, Tint SW 2.0 18.0 15.0 47.31 1.00 707.0 5.Single, Tint W 2.0 18.0 30.0 47.90 0.99 1428.0 6.Single, Tint NW 2.0 18.0 15.0 33.43 1.00 499.0 7.Single, Tint N 20.0 9.5 64.0 24.46 0.64 995.0 8.Single, Tint W 11.0 9.0 128.0 47.90 0.50 3044.0 9.Single, Tint E 6.0 6.5 30.0 53.27 0.55 878.0 10.Single, Tint E 6.6 5.0 6.0 53.27 0.48 151.0 11.Single, Tint N 2.0 16.0 6.0 24.46 0.99 145.0 12.Single, Tint N 2.0 18.0 64.0 24.46 0.99 1554.0 13.Single, Tint S 20.0 9.0 64.0 39.84 0.49 1248.0 14.Single, Tint SW 6.0 6.0 15.0 47.31 0.52 366.0 15.Single, Tint W 13.0 9.5 48.0 47.90 0.48 1103.0 16.Single, Tint NW 5.0 6.5 15.0 33.43 0.69 347.0 17.Single, Tint E 2.0 6.5 102.0 53.27 0.87 4750.0 18.Single, Tint N 2.0 4.5 9.0 24.46 0.86 188.0 19.Single, Tint S 2.0 6.5 90.0 39.84 0.82 2935.0 20.Single, Tint S 2.0 3.5 6.0 39.84 0.66 158.0 21.Single, Tint SW 2.0 6.5 30.0 47.31 0.84 1192.0 22.Single, Tint W 2.0 6.5 122.0 47.90 0.87 5102.0 23.Single, Tint NW 2.0 6.5 30.0 33.43 0.89 890.0 24.Single, Tint N 2.0 6.5 30.0 24.46 0.91 671.0 25.Single, Tint E 2.0 6.5 15.0 53.27 0.87 698.0 26.Single, Tint S 2.0 28.0 30.0 39.84 0.99 1186.0 27.Single, Tint SW 2.0 20.0 30.0 47.31 1.00 1416.0 28.Single, Tint W 2.0 28.0 30.0 47.90 1.00 1431.0 29.Single, Tint NW 2.0 28.0 30.0 33.43 1.00 1000.0 30.Single, Tint N 22.0 8.5 56.0 24.46 0.62 845.0 31.Single, Tint N 2.0 28.0 30.0 24.46 1.00 730.0 32.Single, Tint S 22.0 8.5 56.0 39.84 0.48 1069.0 33.Single, Tint W 18.0 8.5 56.0 47.90 0.42 1127.0 34.Single, Tint W 12.0 8.0 112.0 47.90 0.46 2492.0. 51047.0 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge@ 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 PERMIT #: BASE AS -BUILT WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 570.0 0.70 399.0 1. Concrete, Ext Insul, Exterior 4.1 4356.0 0.48 2090.9 Exterior 4356.0 1.90 8276.4 2. Frame, Wood, Adjacent 11.0 460.0 0.70 322.0 3. Concrete, Int Insul, Adjacent 4.1 110.0 0.65 71.0 Base Total: 4926.0 8675.4 As -Built Total: 4926.0 2483.8 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 44.0 1.60 70.4 1.Adjacent Wood 44.0 2.40 105.6 Exterior 0.0 0.00 0.0 Base Total: 44.0 70.4 As -Built Total: 44.0 105.6 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points . Under Attic 3950.0 2.13 8413.5 1. Under Attic 30.0 3950.0 2.13 X 1.00 8413.5 Base Total: 3950.0 8413.5 As -Built Total: 3950.0 8413.5 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 223.0(p) -31.8 -7091.4 1. Slab -On -Grade Edge Insulation 0.0 223.0(p -31.90 -7113.7 Raised 2360.0 -3.43 -8094.8 2. Raised Wood, Adjacent 11.0 2360.0 1.80 4248.0 Base Total: -15186.2 As -Built Total: 2583.0 -2865.7 INFILTRATION Area X BSPM = Points Area X SPM = Points 5951.0 14.31 85158.8 5951.0 14.31 85158.8 Summer Base Points:113214.9 Summer As -Built Points: 144343.0 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 58000btuh ,SEER/EFF(15.5) Ducts:Con(S),Con(R),Int(AH),R6.0(INS) 144343 0.38 (1.00 x 1.150 x 0.85) 0.220 0.950 11318.5 (sys 2: Central Unit 58000btuh ,SEER/EFF(15.5) Ducts: Con(S),Con(R), Gar(AH), R6.0(INS) 144343 0.38 (1.00 x 1.150 x 0.95) 0.220 0.950 12576.2 (sys 3: Central Unit 3600obtuh ,SEER/EFF(18.0) Ducts:Con(S),Con(R),Gar(AH),R6.0(INS) 144343 0.24 (1.00 x 1.150 x 0.95) 0.189 0.950 6721.7 113214.9 0.3250 36794.8 144343.0 1.00 1.056 0.212 0.950 30687.3 EnergyGaugeTm DCA Form 60OA-2004R EnergyGaugeO/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 n WINTER CALCULATIONS f Residential Whole Building Performance Method A - Details I ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 PERMIT #: BASE I AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Floor Area .18 5951.0 9.11 9758.0 Type/SC Overhang Ornt Len Hgt Area X WPM X WOF = Point 1.Single, Tint E 2.0 21.0 63.0 13.04 1.00 824.01 2.Single, Tint E 6.5 10.0 144.0 13.04 1.09 2051.0 3.Single, Tint S 2.0 18.0 60.0 10.88 0.99 649.0 4.Single, Tint SW 2.0 18.0 15.0 12.36 1.00 185.0 5.Single, Tint W 2.0 18.0 30.0 13.80 1.00 413.0 6.Single, Tint NW 2.0 18.0 15.0 15.30 1.00 229.0 7.Single, Tint N 20.0 9.5 64.0 15.38 0.99 969.0 8.Single, Tint W 11.0 9.0 128.0 13.80 1.10 1934.0 Mingle, Tint E 6.0 6.5 30.0 13.04 1.15 449.0 10.Single, Tint E 6.0 5.0 6.0 13.04 1.20 93.0 11.Single, Tint N 2.0 16.0 6.0 15.38 1.00 92.0 12.Single, Tint N 2.0 18.0 64.0 15.38 1.00 982.0 13.Single, Tint S 20.0 9.0 64.0 10.68 2.24 1560.0 14.Single, Tint SW 6.0 6.0 15.0 12.36 1.33 246.0 15.Single, Tint W 13.0 9.5 48.0 13.80 1.10 727.0 16.Single, Tint NW 5.0 6.5 15.0 15.30 0.99 228.0 17.Single, Tint E 2.0 6.5 102.0 13.04 1.03 1364.0 18.Single, Tint N 2.0 4.5 9.0 15.38 0.99 137.0 19.Single, Tint S 2.0 6.5 90.0 10.88 1.09 1071.0 20.Single, Tint S 2.0 3.5 6.0 10.88 1.39 90.0 21.Single, Tint SW 2.0 6.5 30.0 12.36 1.05 389.0 22.Single, Tint W 2.0 6.5 122.0 13.80 1.02 1713.0 23.Single, Tint NW 2.0 6.5 30.0 15.30 1.00 457.0 24.Single, Tint N 2.0 6.5 30.0 15.38 1.00 459.0 25.Single, Tint E 2.0 6.5 15.0 13.04 1.03 200.0 26.Single, Tint S 2.0 28.0 30.0 10.88 1.00 325.0 27.Single, Tint SW 2.0 20.0 30.0 12.36 1.00 371.0 28.Single, Tint W 2.0 28.0 30.0 13.80 1.00 413.0 29.Single, Tint NW 2.0 28.0 30.0 15.30 1.00 458.0 30.Single, Tint N 22.0 8.5 56.0 15.38 0.98 847.0 31.Single, Tint N 2.0 28.0 30.0 15.38 1.00 460.0 32.Single, Tint S 22.0 8.5 56.0 10.88 2.28 1387.0 33.Single, Tint W 18.0 8.5 56.0 13.80 1.11 858.0 34.Single, Tint W 12.0 8.0 112.0 13.80 1.10 1702.0 As -Built Total: 1631.0 24332.0 c - • EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 Y WINTER CALCULATIONS • Residential Whole Building Performance Method A - Details .I ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 PERMIT #: BASE AS -BUILT WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 570.0 1.80 1026.0 1. Concrete, Ext Insul, Exterior 4.1 4356.0 2.36 10280.2 Exterior 4356.0 2.00 8712.0 2. Frame, Wood, Adjacent 11.0 460.0 1.80 828.0 3. Concrete, Int Insul, Adjacent 4.1 110.0 2.08 228.8 Base Total: 4926.0 9738.0 As -Built Total: 4926.0 11337.0 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 44.0 4.00 176.0 1.Adjacent Wood 44.0 5.90 259.6 Exterior 0.0 0.00 0.0 Base Total: 44.0 176.0 As -Built Total: 44.0 259.6 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 3950.0 0.64 2528.0 1. Under Attic 30.0 3950.0 0.64 X 1.00 2528.0 Base Total: 3950.0 2528.0 As -Built Total: 3950.0 2528.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 223.0(p) -1.9 -423.7 1. Slab -On -Grade Edge Insulation 0.0 223.0(p 2.50 557.5 Raised 2360.0 -0.20 -472.0 2. Raised Wood, Adjacent 11.0 2360.0 1.80 4248.0 Base Total: -895.7 As -Built Total: 2583.0 4805.5 INFILTRATION Area X BWPM = Points Area X WPM = Points 5951.0 -0.28 -1666.3. 5951.0 428 -1666.3 Winter Base Points: 19638.0 Winter As -Built Points: 41595.8 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 58000 btuh ,EFF(9.0) Ducts:Con(S),Con(R),Int(AH),R6.0 41595.8 0.382 (1.000 x 1.160 x 0.87) 0.379 0.950 5797.2 (sys 2: Electric Heat Pump 58000 btuh ,EFF(g.0) Ducts:Con(S),Con(R),Gar(AH),R6.0 41595.8 0.382 (1.000 x 1.160 x 0.95) 0.379 0.950 6301.3 (sys 3: Electric Heat Pump 36000 btuh ,EFF(9.0) Ducts: Con(S),Con(R),Gar(AH),R6.0 41595.8 0.237 (1.000 x 1.160 x 0.95) 0.379 0.950 3911.2 19638.0 0.5540 10879.5 41595.8 1.00 1.073 0.379 0.950 16073.5 EnergyGauge 10 DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 a FORM 60OA-2004R EnergyGauge® 4.5 WATER HEATING & CODE COMPLIANCE STATUS Y Residential Whole Building Performance Method A - Details ADDRESS: 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 5 2460.00 12300.0 80.0 0.86 5 1.00 2631.63 1.00 13158.1 As -Built Total: 13158.1 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling + Heating + Hot Water = Total Points Points Points Points 36795 10879 12300 59974 30687 16073 13158 59919 PASS • EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 511 S.W. PORT ST LUCIE-BLVD, PORT ST LUCIE, FL, 34953 PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed of the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfrn from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on pedmeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. • EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge@/FlaRES'2004 FLRCSB v4.5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 87.1 The higher the score, the more efficient the home. GROZA BUILDERS, INC, 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL, 34953 1. New construction or existing New _ 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 4. Number of Bedrooms 5 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ft2) 5951 ft2 7. Glass type and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 631.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 7b. (Tint) 631.0 ft2 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 223.0(p) ft _ b. Raised Wood, Adjacent R=11.0, 2360.0ft2 _ c. N/A 9. Wall types a. Concrete, Ext Insul, Exterior R=4.1, 4356.0 ft2 _ b. Frame, Wood, Adjacent R=11.0, 460.0 ft2 _ c. Concrete, Int Insul, Adjacent R=4.1, 110.0 ft2 _ d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic R=30.0, 3950.0 ft2 b. N/A c. N/A _ 11. Ducts a. Sup: Con. Ret: Con. AH: Interior Sup. R=6.0, 100.0 ft2 b. 2 Others 200.0 ft _ 12. Cooling systems a. Central Unit b. Central Unit c. Central Unit 13. Heating systems a. Electric Heat Pump b. Electric Heat Pump c. Electric Heat Pump 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a r L Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Off, 0 ''' Address of New Home: IS�(J�i� �1 �S agog City/FL Zip: r E( C_Q :J, Cap: 58.0 kBtu/hr _ SEER:15.50 _ Cap: 58.0 kBtu/hr SEER:15.50 _ Cap: 36.0 kBtu/br _ SEER- 18.00 _ Cap: 58.0 kBtu/hr HSPF:9.00 _ Cap: 58.0 kBtu/hr _ HSPF:9.00 _ Cap: 36.0 kBtu/hr HSPF: 9.00 Cap: 80.0 gallons EF: 0.86 *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarTmdesignation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. -Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. I Predominant glass type. For actual glass type and areas see Summer & Winter Glass output on ages 2&4. i✓nergyGauge® (Version: FLRC0 v4.5) PT, Project Summary Job: 06549 7 Date: 8-30-07 zone 1 By: J.S. PERFECT COOLING INC. Pro'ect Information For: GROZA BUILDERS, INC 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL 34953 Phone: 772-336-7105 Notes: GROZA BUILDERS residence for: WILLIAMS ST LUCIE COUNTY Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 40303 Btuh Ducts 0 Btuh Central vent (65 cfm) 1996 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 42299 Btuh Infiltration Method Construction quality Fireplaces Area (ftz) Volume (ft3) Air changes/hour Equiv. AVF (cfm) Simplified Average 0 Heatin Cool2051 in 20056 20056 0.29 0.16 97- 52 Heating Equipment Summary Make CARRIER Trade Model 25HNA96OA003 // FE4ANB006 Efficiency 9 HSPF Heating Input Heating output 57000 Btuh @ 470F Temperature rise 27 OF Actual air flow 1900 cfm Air flow factor 0.047 cfm/Btuh Static pressure 0.00 in H2O Space thermostat Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative (tumidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure Ducts Central vent (65 cfm) Blower Use manufacturer's data Rate/swing multiplier Equipment sensible load 44780 Btuh 0 Btuh 1069 Btuh 0 Btuh y 1.00 45849 Btuh Latent Cooling Equipment Load Sizing Structure 2180 Btuh Ducts 0 Btuh Central vent (65 cfm) 2706 Btuh Equipment latent load 4885 Btuh Equipment total load 50734 Btuh Req. total capacity at 0.74 SHR 5.2 ton Cooling Equipment Summary Make CARRIER Trade Cond 25HNA96OA003 H FE4AN13006 Coil Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 15.5 SEER 43000 Btuh 15000 Btuh 58000 Btuh 1900 cfm 0.042 cfm/Btuh 0.00 in H2O 0.90 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Right -Suite Residential 6.0.101 RSR21889 2007-Aug-30 09:56:13 C:1Documents and SeftingsUoe ComerWy DocumentslWrightsoft HVAC 81GR0ZA107GR0ZA-williams.rrp Cal Page 1 Project Summary Job: 06549 zone 2 Date: By: 8-30-07 J.S. PERFECT COOLING INC. Protect Information For: GROZA BUILDERS, INC 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL 34953 Phone: 772-336-7105 Notes: GROZA BUILDERS residence for: WILLIAMS ST LUCIE COUNTY Design • • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 34843 Btuh Structure 43454 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (106 cfm) 3253. Btuh Central vent (106 cfm) 1743 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 38096 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 • Infiltration Equipment sensible load 45196 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3658 Btuh Ducts 0 Btuh Area Heating Cooling Central vent (106 cfm) 4411 Btuh (ftz) 2902 2902 Equipment latent load 8069 Btuh Volume (ft3) 29020 29020 Air changes/hour 0.25 0.13 Equipment total load 53266 Btuh Equiv. AVF (cfm) 119 64 Req. total capacity at 0.74 SHR 5.1 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade Trade Model 25HNA96OA003 H FE4ANB006 Cond 25HNA96OA003 // FE4ANB006 Coil Efficiency 9 HSPF Efficiency 15.5 SEER _ Heating Input Sensible cooling 43000 Btuh Heating output 57000 Btuh @ 470F Latent cooling 15000 Btuh Temperature rise 26 OF Total cooling 58000 Btuh Actual air flow 1975 cfm Actual air flow 1975 cfm Air flow factor 0.057 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.85 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Right -Suite Residential 6.0.101 RSR21889 2007-Aug-30 09:56:13 C:\Documents and Settings\Joe Comer\My Documents\Wrightsoft HVAC 8\GR0ZA\07GR0ZA-williams.rrp Cal Page 2 a Project Summary Job: 06549 zone 3 Date: By: 8-30-07 J.S. • PERFECT COOLING INC. Pro`ect Information For: GROZA BUILDERS, INC 511 S.W. PORT ST LUCIE BLVD, PORT ST LUCIE, FL 34953 Phone: 772-336-7105 Notes: GROZA BUILDERS residence for: WILLIAMS ST LUCIE COUNTY Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 26410 Btuh Ducts 0 Btuh Central vent (27 cfm) 832 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 27242 Btuh • Infiltration Method Construction quality Fireplaces Area (ftz) Volume (ft3) Air changes/hour Equiv. AVF (cfm) Simplified Average 0 HeatinOg CoolinOg 6460 6460 0.40 0.21 43 23 Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Reative Humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 29465 Btuh Ducts 0 Btuh Central vent (27 cfm) 446 Btuh Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 29911 Btuh Latent Cooling Equipment Load Sizing Structure 960 Btuh Ducts 0 Btuh Central vent (27 cfm) 1128 Btuh Equipment latent load 2088 Btuh Equipment total load 31999 Btuh Req. total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade Trade Model 25HNA936AO03 // FE4ANF005 Cond 25HNA936AO03 // FE4ANF005 Coil Efficiency 9 HSPF Efficiency 18 SEER _ Heating Input Sensible cooling 25200 Btuh Heating output 35000 Btuh @ 47°F Latent cooling 10800 Btuh Temperature rise 24 OF Total cooling 36000 Btuh Actual air flow 1339 cfm Actual air flow 1339 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.93 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. • Right -Suite Residential 6.0.101 RSR21889 2007-Aug-30 09:56:13 CADocuments and SeftingsUoe ComerWy Documents\Wrightsoft HVAC MROZA\07GROZA-williams.rrp Cal Page 3 Right-J Worksheet Job: 06549 zone 1 Date: 8-30-07 PERFECT COOLING INC. By: J.S. 1 Room name zone 1 foyer 2 Exposed wall 287.5 ft 76.0 ft 3 Ceiling height 9.8 ft d 8.5 ft heaUcool 4 Room dimensions 1.0 x 303.0 ft 5 Room area 2051.0 ft2 303.0 ft' Ty Construction U-value Or HTM Area (W) Load Area (W) Load number (Btuh/ft2-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs 3 0143 .'n 4 DO 2"85 420 `: 318 71273 809 T777776 0 W77776 0 1A hlaind 1A hlom ,' 1 270 1 270 n 'n 35,56 35 56 29955 29 95 64 6 0 0 2276 213 1917 180 0U, - 0 0 0 1Aat1om3; 1 270 n 35:56 2995 ' 32, 0 1136 958 0 r 0 0 �0 35 56 ... MAR .. . ,.,. D � .. 0 0 .,v -' . .�.. 0 .: -:o ... ,.. ...n , 0 ... p 13A-flocs 0.143 a 4.00 2.55 606 378 1514 962 136 64 256 163 1 1A-h1om 1.270 a 35.56 69.02 48 0 1707 3313 24 0 853 1656 10A-b 0.970 a 27.16 45:84 144 61 3911 4897 48 20 1304 1632 1A-hlom 1.270 a 35.56 69.02 30 21 1067 1255 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 6 6 213 181 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A flocs 0143 4 DD 2,55 _ 610 486 1946 1237 0 6 0 6, 1A hlom 1270 °S 35,56 3210 60 60 2134 ;' 1797 0 0 0 0 1A clgmd e 1270 ,s 3556 37 $8 w 64 64 = 2276 2226- LLO 1A h19m 1 270 �s 35`56 3210 0 D 0 0 0 ' t3 0 D , 1 270 s 3556 3210 0 0 1A OW",1270 s 35 56 28 89 0 „' a 0 0 1A hlomd w_„ - L 1,.27.0 s __.-35.56 ,.-.,»2689. 90 60 240 153 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.55 1A-h1om 1.270 sw 35.56 55.03 15 0 533 825 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 15 15 533 449 0 0 0 0 IA-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 13A flocs 3 ) # D 143 1v 4 00 7 , 55 435 229 917 583 0. 0 1A17Qom 1270 w� 3556 6802 30 % D 1067r 2071 0 0 0 0 I hlomd 1270 w 35�b6 6902 128 �128 -4552 1A-ciotnd 1 27q .�iv 35;56 91 12 46 48 17D7 1669 0 0 0 0' 1A h?om 1270 w„ ,3556 6902 0 , 0 0 % 0 1A-hiam � • , 1 270 . ;w 3556 6902 0 , 0 � o � 0 0 1A c1omd 1270 w 3556 8201 0 0 y 0 0 0 1AoM --,,LLI. 270 inr . - 3556 b212 . _ ,.0 _ ._.� . 0 .._ x'0 13A-4ocs 0.143 nw 4.00 2.55 90 60 240 153 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 15 0 533 820 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 15 0 533 820 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54,67 0 0 0 0 0 0 0 0 x fi BEE" W; .. 9ii e t 14.00 ... 11.3 _ ;0.49 .. - 00.. -' a w o M. DO. 13A-4ocs 0, o 0. 0 0 1.6BaQ90 99n-+nh I i ua � u ni %1»6,80 n nn ona 7a -5aon 84 . ' n zrn 7a ' oaon n 61 c) AED excursion 14520 1 1 -384 Envelope loss/gain 37302 37430 5991 3375 12 a) Infiltration 3001 861 181 52 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 3 6489 0 630 Subtotal (lines 6 to 13) 1 40303 44780 6172 4057 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 40303 44780 6172 4057 Duct loads 0% 0% 0 0 0% 0% 0 0 r Total room load 40303 44780 6172 4057 Air required (cfm) 1900 1900 291 172 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsoFC Right -Suite Residential6.0.101 RSR21889 2007-Aug-3009:56:13 ACC C:1Documents and Settings ioe ComerlMy DocumentslWrightsoft HVAC 81GR0ZA\07GR0ZA-williams.rrp Cal Page 1 Right-1 Worksheet Job: 06549 zone 1 Date: 8-30-07 PERFECT COOLING INC. By: J.S. 1 Room name dining pantry 2 Exposed wall 29.0 ft 0.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 It heat/cool 4 Room dimensions 1.0 x 210.0 ft 1.0 x 50.0 ft 5 Room area 210.0 ftz 50.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load number (Btuh/ft2-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6' W 13A-4ocs 1A-tilomd ; D 143 1.270 ;n , h 4 D0 3556 2 55 2995 0 0 0 0 0 0, 0 0= al D 0 1A h1om 1 270 ',n 3556 2995 0 . - 0 0 0 . 0' 0 0 L. 0 1A h1om 35:56 29._95 0 0 0 0 0 0 1.27, .n 3556, :29,95_„ 0 0. .'` _._0 ..;:r, ,n n; •. ..,_n .,. .=•',n .. h 13A-40cs 0.143 a 4.00 2.55 150 102 408 260 lA-hlom 1.270 a 35.56 69.02 0 0 0 0 10A-b 0.970 a 27.16 45.84 48 20 1304 1632 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 13g4pcss w 0143 S 40D 255 140 7110 44D 28q 1A hlotCt E 1.270 : S 35;56 3, 30 30 1067 899 1A c-ord 1A hlom 1 27D s 35:56 32.10 0 0 0 0 1A irlorn 1.270 S 35`.56 „3210 0 0 1A hlom; 1.270 ss 3556 2888 0 0 0 `, q 1A 61:o[nd __ `1270 s_ _3556 w2889..._.._...,u._,0. 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 IA-hlom 1.270 nw 35.56 54.67 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 1A hlom 1.270 nw 35.56 54.67 0 0 0 12B Osw� g _ 0 097 :' 2 72 57, 0 T O 0 11DO 390. _ e _ _.J0:92 _ 11.i31, 0 0 MO 13A13ocs 0.143 4.00 1 49 0 0 0 32.�.�,- _ 22A tph 1 358 38.02 0 00 0 0 0 D7a. a 21.0. , D. _. 459, 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 40 a o 10 0 a' p! p p 0. 0 b o �0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 61 c) AED excursion -320 1 1-11 Envelope loss/gain 3678 2955 154 121 12 a) Infiltration 387 111 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 315 0 0 Subtotal (lines 6 to 13) 4065 33811 1541 121 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4065 3381 154 121 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 4065 3381 1 154 1 121 Air required (cfm) 192 143 1 7 5 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr1 j:-] H soft Right -Suite Residential 6.0.101 RSR21889 2007-Aug-30 09:56:13 G. P. C:\Documents and SettingsWoe Comer\My Documents\Wrightsoft HVAC 8\GROZA\07GROZA-williams.rrp Cal Page 2 Right-J Worksheet Job: 06549 zone 1 Date: 8-30-07 PERFECT COOLING INC. By: J.S. 1 Room name kitchen breakfast 2 Exposed wall 18.0 It 43.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 It heat/cool 4 5 Room dimensions Room area 1.0 x 290.0 ft 290.0 ft2 1.0 x 275.0 It 275.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (13tuh/ff-'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross I N/P/S Heat I Cool Gross I N/P/S Heat I Cool irl 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 1A hlam 1 1.270 a 35.56 69.02 0 0 0 0 13A-4ocs C 0 143 s 4 OD 2 55 180 fly ?80 721 458 1A Marl 1 270 s 3556 3210 ' 0 00 0 1A c1omd a 1 27D s 35`56 37 88 0 0 0 0 1Ahlorrl' t� 1270 'S 356 3210 1A-h?om �127D s 3556 32h0 1 0 � 0 0 �" � 0 1A t(1am 'i 1 270 & 35'56 28.89 ;; 0 0 D r o 1A=hTorE7d. 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 IA-hlom 1.270 sw 35.56 55.03 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 1A-h1om 1.270 sw 35,56 55.03 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 45 30 120 76 15 0 533 825 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 45 30 120 76 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 15 0 533 820 1A-h1om 1 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1Ah1om 1270 nw 3556 5467 0 0 0 0 0 0 0 0 126-0sw O 097 2 72 1k570 D 0 0 0 0 0 0 13A flocs ( 0.143 4 00 1 49 0 0 0 11- 0_ 0 0 0 0 1.56„$badU.9D.7.8<.:`0.0.0. 22A-tnh 1 3.riR _ 3R n9 n nn n n n _ .,_l7-0 n n n ...._, n n 61 c) AED excursion -306 1 -96 Envelope loss/gain 1354 435 7182 7406 12 a) Infiltration 240 69 573 165 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 1 2730 0 0 Subtotal (lines 6 to 13) 1594 3234 T7551 7571 i Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution j 0 0 0 0 14 Subtotal 1594 3234 7755 7571 15 Duct loads 1 0% 0% 0 0 0% 0% 0 0 Total room load 1594 3234 7755 7571 Air required (cfm) 75 1371 366 321 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. C Wr�ghtsofC Right -Suite Residential 6.0.101 RSR21889 2007-Aug-3009:56:13 . C& C:\Documents and SettingsUoe Comer\My Documents\Wrightsoft HVAC 8\GROZA\07GROZA-williains.rrp Cal Page 3 I Right-J Worksheet zone 1 PERFECT COOLING INC. Job: 06549 Date: 8-30-07 By: J.S. 1 Room name loft stairs 2 3 Exposed wall Ceiling height 22.0 ft 10.0 ft heaUcool 30.0 ft 10.0 ft heat/cool 4 Room dimensions 1.0 x 433.0 ft 1.0 x 80.0 ft 5 Room area 433.0 ft2 80.0 ft2 Ty Construction ! number U-value (Btuh/ftLoF) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross I N/P/S Heat I Cool Gross I WP/S Heat I Cool 13Acs 0.143 a 4.00 2.55 0 0 0 0 170 116 464 295 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 24 0 853 1656 10A-b 0.970 a 27.16 45.84 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 30 21 1067 1255 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A flocs �� 143 5 4 OD 2 55 0 0 0k: 0 �'50 200 t 27? 1El hlom V,UD 1270 s 35 56 32 jDCl� U D D 0 ED 1 D4 p 1Aclomrl 1 270 g S; 3556�""3788� 0 0 03, ¢� Y, 0 p 0 0. , 1A h1om " 1 �7D S�, 3556 3210 D P D D 0 ab 0 0 0; 1Ah1oinf 1270 3556 3210:� 0 0 0 0 1Ailom fi 1 270 .s ,s 35"56 28:89 0 r D 0= p 0' aA%lomd .27_D ';sZ . _.3556. ,_: _32889 ML=D. L:. ga0 _ 0.LLLLA _ tl 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 . 0 0 1A-hlom 1.2730 sw 35.56 55.03 0 0 0 0 0 0 0 0 IA-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 IA-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 12B-0sw II 097 - 272 1a57 0 0 0 t b ;; 0,- 0.390 e.._� 1oba 11.31.. 0. ,.: O..,W ....Q.. .-U 13A-4ocs 0.143 - 4 00 1.49 0 0 0 0 0 0 0 0 16ts3Ddd 2R.032 -_ Q0__�68` w_Q,,U.___ 0.'nQ -Q :�� 1J„Q i" a ara _ sa m n nn n n o 0 0 0 0 0 �,,.,.�,.�a ,,.,.. ,.w�,...urF ....>.�x h�...�.v.. -r mad. ,,:; . u��., ,_.:: ,.,,, .,� _.., '' .,ra ..........,.�.. me z M,.....s.,,x...,. ..a� ...� z r ..:�...,�:,,.�..........,�. ,..,.. 3,n.,.w_.,,��� ... _....:s_ .vF�ldx.,.�.;.v.J „.I-,.,..m.az-�..,. 6 c) AED excursion 4376 -384 Envelope loss/gain 5204 8571 3080 3231 12 a) Infiltration 293 84 400 115 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 0 0 714 Subtotal (lines 6 to 13) 5497 8655 3480 4060 Less external load 1 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5497 8655 3480 4060 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load ! 5497 8655 3480 4060 Air required (cfm) 259 367 164 172 (Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrig htsofit Right -Suite Residential 6.0.101 RSR21889 2007-Aug-30 09:56:13 .'C-N C:1Documents and SettingWoe ComerXMy Documents%Wrightsoft HVAC B\GROZA107GROZA-williams.rrp Cal Page 4 I Right-.1 Worksheet Job: 06549 zone 1 Date: 8-30-07 By: J.S. PERFECT COOLING INC. 1 Room name den den bath 2 Exposed wall 10.0 ft 18.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat1cool 4 Room dimensions 1.0 x 105.0 ft 1.0 x 65.0 ft 5 Room area 105.0 ft' 65.0 ft2 Ty Construction U-value Or HTM Area (ftq Load Area (ftj Load number (Btuh/ft�°� (Btuh/ft2) or perimeter (ft) (Btuh) 0r perimeter (ft) (Btuh) Heat I Cool 1 Gross I N/P/S Heat I Cool Gross I N/P/S Heat I Cool i lrll 13A-4ocs 0.143 a 4.00 2.55 100 52 208 132 50 44 176 112 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 10A-b 0.970 a 27.16 45.84 48 20 1304 1632 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0, 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 B 6 213 181. 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A-40cs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 t 0 097r 2F7 1� 570 ` 0 " 00 0 �-0 �0 Q M126-0swF �, �. '.w_ aim �:.'4.. 1 is N1z1.3�, .->.�...:.A Etla � .,a.:.�.�,0. a - ...,� ��0 �- � .D �',�w Q r..M.M`.z.�:.r � 0.: 13A-4ocs i 0.143 - 4.00 1.49 0 0 0 0 0 0 0 0 60 Oad..v 32 B D 1 <6' z 0 99a_tnh aFR _ aR rn n nn n n n n n n n n 6 c) AED excursion 1-346 -80 Envelope loss/gain 1741 1521 1241 772 12 a) Infiltration 133 38 240 69 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 1 2100 0 0 Subtotal (lines 6 to 13) 1 1875 3659 14811 841 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1875 3659 1481 841 151 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 1875 3659 1481 841 Air required (cfm) 88, 1551 70 36 I _ Printout certified by ACCA to meet all requirements of Ma wrrfghtsoft Right -Suite Residential6.0.101 RSR21889 .9GZA C:\Documents and SettingsWoe Comer\My Documents\Wdghtsoft HVAC MGROZA\07GROZA-williams.rrp Cal 2007-Aug-30 09:66:13 Page 5 Right-J Worksheet Job: 06549 l ; zone 1 Date: 8-30-07 By: J.S. PERFECT COOLING INC. I 1 Room name piano area 2 Exposed wall 41.5 ft 3 Ceiling height 1 10.0 ft heat/cool 4 Room dimensions 1.0 x 240.0 ft 5 Room area 240.0 ft' Ty Construction U-value Or HTM Area (ftq Load Area Load number (l3tuh1W °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter Heat Cool Gross I N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 13A40cs 0.143 a 4.00 2.55 0 0 0 1A-hlom 1.270 a 35.506 69.02 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 IA-hiom 1.270 a 35.56 69.02 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 sw IA- 1A h om 0. 143 I I 11.270I ssww I 335.56 55.035 56I 55.03I 15 15 530I 44C 13A-4ocs 0.143 nw 4.00 2.55 45 30 120 76 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 15 0 533 820 1A-hlom 1.270 nw 35.56 54.67 0 0 0 C 1A-h1om 1.270 nw 35.56 54.67 0 0 0 C 128 OsWi _ 0 097 = 272 1a57 mm , 9.3.Q0 e z 1,0s92 1:C31,.sx:.x .0 �.F r0. __ �, _2_- C 13A-4ocs 0.143 - 4.00 1.49 0 0 0 C 168oads;,30.03 _" 09,0 ,[ 68_ _0 _ 0. 0, :r M C 6 c) AED excursion /U« Envelope loss/gain 7677 9042 12 a) Infiltration 553 159 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances @ 2100 0 10 Subtotal (lines 6 to 13) 8230 9201 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 8230 9201 15 Duct loads 0% 0% 0 0 Total room load 8230 9201 Air required (cfm) 1 1 3881 390 AC�GA C:1Documents and (Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 9t Right -Suite Residential 6.0.101 RSR21889 Zoe ComerlMy Documents%Wrightsoft HVAC 8\GROZA\07GROZA-williams.rrp Cal 2007-Aug-30 09:56:13 Page 6 Right-J Worksheet zone 2 PERFECT COOLING INC. Job: 06549 Date: 8-30-07 By: J.S. 1 Room name zone 2 great room 2 3 Exposed wall Ceiling height 281.5 ft 10.0 ft p 28.0 ft 10.0 ft heat1cool 4 Room dimensions 1.0 x 600.0 ft 5 Room area 2902.0 ftz 600.0 ftz Ty Construction U-value Or HTM Area (ft) Load Area (ftj Load number (Btuh/ft;°F) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross I N/P/S Heat I Cool Gross I N/P/S Heat I Cool irl. 13A-40cs 0.143 a 4.00 2.55 620 488 1954 1242 70 55 220 140 1A-hlom 1.270 a 35.56 69.02 15 0 533 1035 15 0 533 1035 10A-b 0.970 a 27.16 45.84 0 0 0 0 0 0 0 0 IA-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 IA-hiom 1.270 a 35.56 69.02 102 3 3627 6912 0 0 0 0 1A hiom 1.270 a 35.56 69.02 15 0 533 1017 0 0 0 0 13A�OCs ; 0143 •S 4;00 Z55 665 569 _ 2278 1448 0 A 0 0 1Ahlom 1270 s 3556 3210, 0 t o D 1A c1omd a 127D s 35 56 37 88 z 1A hiom ' 127p s 35 56 3 f3210 90 9D 32oD 2695 o p 0 0 1A hiom 1270 s 35�56 32.10 6 6 213 18D; 0 �0 ' 0 0 1A h10iTr, 1 270 s 3556 28;89 0 0 D 0 00 0 0 1A h lomd 1270" s_ 35 66 28`89_ 0, 0, • 0. r :w." 0 awt0 . "- £ 0.0: 13A-40cs 0.143 sw 4.00 2.55 90 60 240 153 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 30 14 1067 1308 0 0 0 0 1A-hiom 1270 sw 35.56 55.03 0 0 0 0 0 0 0 0 13A flocs ` 0 143 w 4;00 2'155 430 ` 308 1233 784 q 1A hiom i 270, w" 35s56 .r , 69 02 .. .."' , ; 0 v. 0 > _ ..'0 0 0, 13A-flocs IA-hiom 1A-hlom 1A-hlom 0.143 nw 1.270 nw 1.270 nw 1.270 nw 1.270 nw Q39.Q ,tee 0.143 0 032 1 arR - 2.55 90 60 240 153 0 54.67 0 0 0 0 0 54.67 0 0 0 0 0 54.67 30 0 1067 1640 0 u ;u 0 0 0 0 0 0 0 0 61 c) AED excursion 3819 1 1 -124 Envelope loss/gain 31183 40224 3915 3048 12 a) Infiltration 3660 1050 373 107 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 0 0 Appliances @ 2100 0 1029 0 0 Subtotal (lines 6 to 13) 34843 43454 4288 3155 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 34843 43454 4288 3155 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 34843 43454 4288 3155 Air required (cfm) 1975 1975 243 143 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsoft Right -Suite Residential 6.0.101 RSR21889 2007-Aug-3009:56:13 ACC C:\Documents and Settings\Joe Comer\My DocumentslWrightsoft HVAC 8\GROZA\07GROZA-williams.rrp Cal Page 7 Right-J Worksheet zone 2 PERFECT COOLING INC. .Job: 06549 Date: 8-30-07 By: J.S. 1 Room name bedroom 3 bath 3 2 Exposed wall 30.0 ft 5.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 225.0 ft 1.0 x 50.0 ft 5 Room area 225.0 ft2 50.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool 1 Gross I N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 13A-40cs 0.143 a 4.00 2,55 160 130 521 331 0 1A-h1om 1.270 a 3156 69.02 0 0 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 0 0 1A-h1om 1.270 a k56 69.02 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 30 1 1067 2033 0 1A h1OCgdu -` .. _ .:..." 1:27_0 5 ..w::3.5 55 LL 28 89. 0. 3 U 0, • ..;; .._.W}7 �� 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 0 0 IA-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 1A h1om 1.270 35.56 55.03 0 0 0 0 ^sw _ _0 1A hlom 1270 ;w 35y56 69C12 0 0 0 0 : 0 1A hlomd 1 270 w 35 56 69 02 0 0 0 0 0 1A clomd 1270 w 35:56 91 12 0 0 0 0 0 1A hlvm 1 270 3w 35 56 6902 0 a 4 0�� 0 0 1A h1an1 .- 1 270 d�v. 35 56 69:02 �0 0x s 1A-clomd ;':F 1 270 w 3556 8201 0 0 0 0 0 1A-M'tim� __ _. <,; 13A-40cs 0.143 nw 4.00 2.55 0 0 0 0 C IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 C IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 C 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 C 1A-hlom 1.270 nw 35_56 54.67 0 0 0 0_ C 12B-0svr „ 0 097 W 2;72 1_1,D-0.._ 0:390 '.• e W 10.92-1.1:31,. 13 '-4 0.143 - 4.00 1.49 0 0 0 0 C 168„30ad168_ _'22a _ 97A-}nh 135B - 3B.n7 0.0❑ 0 0 0 0 C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I 0 0 0 0 0 0 0 O 0 0 0 0 61 c) AED excursion 54 1 15 Envelope loss/gain 2349 3152 434 381 12 a) Infiltration 400 115 67 19 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 2100 0 0 0 0 Subtotal (lines 6 to 13) 2749 3497 501 400 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2749 3497 501 400 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 2749 3497 501 400 Air required (cfm) 156 159 28 18 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsOFC Right -Suite Residential6.0.101 RSR21889 2007-Aug-3009:56:13 to C:\Documents and SettingsUoe Comer\My Documents\Wrightsoft HVAC B\GR07A\07GROZA-williams.rrp Cal Page 8 Right-J Worksheet Job: 06549 zone 2 Date: 8-30-07 By: J.S. PERFECT COOLING INC. 1 Room name Cl 3 play room 2 Exposed wall 0.0 ft 11.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 ft 1.0 x 90.0 ft 5 Room area 50.0 ft2 90.0 ftz Ty Construction U-value Or HTM Area (ft) Load Area (ft) Load number (Btuh/ftz°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross I NIP/S Heat Cool Gross N/P/S Heat Cool 13A-40cs 0.143 a 4.00 2.55 0 0 0 0 80 50 200 127 1A-hiom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 30 1 1067 2033 1A hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A 4t7C5 , D 143 S " 4 ©D 7 2:55 0 ' 0 0MfW7b 773 25 f 25 1007T�64 1A hiom, WO 0 d 1A cAorrtdi �;1 270s 35 56 37.88� 0 = 0 ' 0 1A hiom 12,70 s 35 56 3210 0 0 0 L 0 0 t7 0 0 1A h1om 127D s 35 56 3210,0, 1A hlY ;, � � c 1.270 g 35!a�6 28$9 � �0 ' 0 �-_ `.0.... 1q,ha. 0tndL..�.�.,' • .� �A270 ,0 � . , A • U : 0 . ,. 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A h1om 1.270 sw 35.56 55.0& 0 0 0 0 0 0 0 0 13A flocs 0 143 w 54:00 2 55 0 0 0 0, v 0 t) 0 0 1A h10m i 270 w 35.56 69, 02 0 D 0 0 0 1A h1ojnd ; 1 270 w 35 56 69 02 0 0 0 0 0 0 0 0; 1A clorrzd 7 270 Hr 3556 91x12 0 0 �0 , 0 Q 9 0 U lA hiom a z a1 270 vir 35'36 69.62 P� 0 r0 0� 0 0 0 1A hlon 12701N 3556 " 69 02 ri 0 0 00 Q 1Ac1oird 1270 w 3556 82:01 0 D 0 0 0 D Q 1A 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-hiom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1270 nw 35.56 54,.67 0 0 0 0 0 0 0 0 12B 1)sW _ 0 097 272 1:57 0 0 __ 0 0 0 ;0 , 0 0 .. OA9 _0. 5 0. Q : _ : 0 . 0 . _�. :Q 13A-4ocs 0.143 4.00 1.49 0 0 0 0 0 0 0 0 1 �Fa _ sa n� n nn n n n 0 0 0 0 0 61 c) AED excursion 1 -8 54 Envelope losstgain 45 76 1448 2429 12 a) Infiltration 0 0 140 40 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 0 0 1029 Subtotal (lines 6 to 13) 145 76 1588 3498 Less external load 0 D 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 45 76 1588 3498 15 Dud loads 0% 0% 0 0 0% 0% 0 0 Total room load 45 76 1588 3498 Air required (dm) 3 31 1 190 1159 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr^�ghtsOFC Right -Suite Residential 6.0.101 RSR21889 2007-Aug-3009:56:13 . li C:1Documents and SettingsUoe ComerWty DocumentslWrightsoft HVAC 8tGROZAWGROZA-williams.rrp Cal Page 9 Right-J Worksheet zone 2 PERFECT COOLING INC. Job: 06549 Date: 8-30-07 By: J.S. 1 Room name bedroom 4 bath 4 2 Exposed wall 31.0 ft 0.0 ft 3 Ceiling height 10.0 ft heattcool 10.0 ft heat/cool 4 Room dimensions 1.0 x 240.0 ft 1.0 x 60.0 ft 5 Room area 240.0 ft2 60.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftMF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool 1 Gross N/P/S Heat I Cool 1 Gross I N/P/S Heat Cool 13A-40cs 0.143 a 4.00 2.55 150 120 480 305 • 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 30 1 1067 2033 0 1A hlom 1.270 a 35.56 69.02 0 0 0 0 0. 13A 40 D,143 S 4,OD 2'S5 h 160 160 641 407 v 0 �_ 1,27032`�10 0 0 ,,' 0,- 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 IA-hlom 1.270 sw 35.56 55.03 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 13A-40s 0.143 nw 4.00 2.55 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 1A-hlom 1.270 nw 54.67 0 0 0 0_ 0 _ 126 Osv� 50 097 = `; _35.56 s 2 72 1:57 0 0 0 0 Q 11D,0:�.:,„� _�_ ,�-:_0 300, 0.143 - �_wi092 4.00 1131_ 1.49 ..w.__0. 0 � __,�_0,„_,�, 0 4...�:_.__ 0 _, 0.�,,.,s 0 �:,.,�•0 0 13A-4ocs 22A tph, 1.358 38.02 0.00 0 0 0 0 0 20PY.11t.. , 211 a 0,07_8 - 2 B 0;9$,__.=a _ 0 =125 .0 , ,77 0 0 0 0 0 0 0 0 0 0 0 0 � � � 000 0 0 0 _ 0 0 0 0 0 0 0 61 c) AED excursion 49 1 1-9 Envelope loss/gain 2403 3198 54 91 12 a) Infiltration 413 119 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 2100 0 0 0 0 Subtotal (lines 6 to 13) 2816 3547 54 91 Less,extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2816 3547 54 91 15 Duct loads 0% 0% 0 0 0% 0%1 01 0 Total room load 2816 3547 54 91 Air required (cfm) 160 161 3 4 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ght50'� Right -Suite Residential6.0.101 RSR21889 2007-Aug-3009:56:13 4CZrA C:\Documents and Settings\Joe ComerWly Documents\Wrightsoft HVAC 8\GR0ZA\07GR0ZA-williams.rrp Cal Page 10 a Right-J Worksheet Job: 06549 zone 2 Date: 8-30-07 PERFECT COOLING INC. By: J.S. 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area master bath 12.0 ft 10.0 ft heaVcool 1.0 x 80.0 ft 80.0 ftz master toilet 0.0 ft 10.0 ft heat/cool 1.0 x 30.0 ft 30.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (W) Load number (Btuh/ft' °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross I N/P/S Heat I Cool Gross I NIP/S Heat I Cool 13A-40cs a:1" a 4.00 2.55 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 13A-40cs 0.143 sw 4.00 2.55 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 1A-h1om. 1.270 sw 35.56 55.03 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 1A h1om 1.270 nw 35 56 54.67 0 0 0 0 0 12B-0sw < 0 097 2 727.157 0 0 0 0 0 . 11:3.i kmLto„ 13A-4ocs 0.143 - 4.00 1.49 0 0 0 0 0 ]6¢ 3.Qad 80 _ �7>2.t34._ 30 22A-tnh �5R _ aR ro n nn n n n n . n 6 c) AED excursion Envelope loss/gain 12 a) Infiltration b) Room ventilation 13 Internal gains: Subtotal (lines 6 to 13) Less external load Less transfer Redistribution 14 Subtotal 15 Dud loads Total room load Air required (cfm) 33 865 782 107 31 0 0 0 0 0 0 972 813 0 0 0 0 0 0 972 813 0% 0% 0 0 972 813 551 37 0 0 0 0 0 0 0 0 0 0 0 0 0I 0 0 0 0 0 0 0 0 0 0 0 0 0 00 -5 27 46 0 0 0 0 0 0 0 0 27 46 0 0 0 0 0 0 27 46 0% 0% 0 0 27 46 2 2 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Aftwr�ghtsofC Right -Suite Residential 6.0.101RSR21889 2007-Aug-3009:56:13 C:1Documents and SeftingsWoe ComerlMy Documents\Wrightsoft HVAC 8\GROZAWGROZA-williams.rrp Cal Page 11 Right-J Worksheet Job: 06549 zone 2 Date: 8-30-07 By: J.S. PERFECT COOLING INC. 1 Room name master bath 1 master bedroom 2 Exposed wall 12.0 ft 35.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 80.0 ft 1.0 x 310.0 It 5 Room area 80.0 ft 310.0 ft' Ty Construction U-value Or HTM Area M Load Area (ftj Load number (Btuh/ft;°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross I N/P/S Heat I Cool i Gross I N/P/S Heat I Cool &W.6m ` -1 27.,0 A 35--56 . k 29 9r�_ . �. ,_D. _. R _w. . �0 x 13A-flocs 0.143 a 4.00 2.55 0 0 0 0 0_ 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A h1om 1.270 35.56 69.02 0 0 0 0 0 0 0 0 13A flocs 0 143 •e S 4 DD Z'S5 720 114 456 290 160 115 7460 293 1A h1om 1270 s 3556 3210 _ 1A c1omd 1 270 s� 35 56 3T�8 0 0 0 1A hlom 1 270 S 35`56 32;10 0 0 0 0 4.5 ° 45 1600 1348 1A hlom 127D s 3556 3210 6 6 213 180 0 0 0 0 1A hlom 1 270 S 35'56 28;89 0 0 0 1hldmd ... .. A. __ - 1 27.0 _ _3556 a2689. Q :... _Q 13A-4ocs 0.143 sw 4.00 2.55 0 0 0. 0 45 30 120 76 IA-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 0 15 7 533 654 1A hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 13A 4pcs 1Ah1om t7 143 1270 w w 4`QO 3556 ' 255 69.02 0 0 =0 0 0 0 0 0 100 0 7Q 0 7280 0 77 0 1A hlomd 1 270 w 3556 69'02 0 0 0 0 0 ,+ 0 0 0 1A G1ond' ° 1270 �hra 35 56 91:12 0 r 0 D� 1A h1om 1270 w 35:56 69.02 0 0 0 0 30' „1 1067 2Q33 �A tiiom 1270 . •w 3556 69,02 0 0 0 0 0 0 A 1A-c1omd1270 v✓ 3556 8201 0 0 0 0 0 4 0 r 0`. lA'haom ... ._,.,_1270 0 .,., 0 _ '.A.. . .. w..0: _._ 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 45 30 120 76 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 15 0 533 820 1A-h1om 1.270 35.56 54.67 0 0, 0 0 0 0 0 0 126-0sw 0097 _nw 272 1'S7 0 0 0 0' „_ 0 0' 0 0, 11D0° w0.39Q tee_ 10r92J1.3l 13A-w4ocs 0143 - 4.00 149 0 0 0 0 0 0 0 0 68_ 80. 80, 'r 72. _�._134, . 99A-4nFh 1 35A - 3R ❑7 n ❑0 0 0 0 0 0 0 D D 61 c)AED excursion -1 t$ 131Y Envelope loss/gain 741 586 4993 7311 12 a) Infiltration 160 46 467 134 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances @ 2100 0 0 0 0 Subtotal (lines 6 to 13) 901 632 5459 7905 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 901 632 5459 7905 15 Duct loads 0% 0% 0 0 0% 0 0 0 0 Total room load 901 632 5459 7905 Air required (cfm) 51 29 309 359 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr14LCjhtsoft Right -Suite Residential6.0.101 RSR21889 2007-Aug-3009:56:13 Ar C:\Documents and SettingsWoe ComerWly Documents\Wrightsoft HVAC MROZA107GROZA-williams.rrp Cal Page 12 Right-J Worksheet zone 2 PERFECT COOLING INC. Job: 06549 Date: 8-30-07 By: J.S. 1 Room name master cl her master cl his 2 Exposed wall 0.0 ft 0.0 ft 3 Ceiling height 10.0 It hea/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 70.0 ft 1.0 x 50.0 ft 5 Room area 70.0 f12 50.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool 1 Gross N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 1Aiiigm�__ _.> I _1270,1 1� 35561 :2995,I AL O.I� 01. 13A-4ocs 0.143 a 4.00 2 55 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 0 IA-hlom 1.270 a 35.561 69.02 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 1A-hlom 1.270 sw 345 66 55.03 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 13A-40cs 0.143 nw 4.00 2.55 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 1A-h1om 1270 nw 35.56 54.67 0 0 0 0 0 126-0sw 0 097 2 72 1:57 0 _ 0 0 _ 0 _ 0 039.0. Le 10 92 1 0 13A-4ocs 0.143 4.00 1.491;34. 0 0 0 0 0 66 30ad_<_ _. �:: _0 032 7�77�> 0 90.1680 ?_0 70 '; .;• .63 __ 118. ' 5.D 99A-tM 1 q;Rl RR n9 n nn n n n n 0 6 c) AED excursion Envelope lossigain 12 a) infiltration b) Room ventilation 13 Internal gains: Subtotal (lines 6 to 13) Less external load Less transfer Redistribution 14 Subtotal 15 Dud loads Total room load Air required (dm) -11 63 107 0 0 0 0 0 0 0 0 63 107 0 0 0 0 0 0 63 107 0% 0% 0 0 63 107 4 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -8 45 76 0 0 0 0 0 0 0 0 45 76 0 0 0 0 0 0 45 76 0% 0% 0 0 45 76 3 3 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Aftwrrrghtsoft Right -Suite Residential6.0.101 RSR21889 2007-Aug-3009:56:13 C:\Documents and Settings\Joe Comerft Documents\Wrightsoft HVAC 8\GR0ZA\07GR0ZA-williams.rrp Cal Page 13 Right-J Worksheet Job: 06549 zone 2 Date: 8-30-07 By: J.S. PERFECT COOLING INC. 1 Room name guest room guest bath 2 Exposed wall 46.0 it 9.0 ft 3 Ceiling height 10.0 It heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 256.0 ft 256.0 ftz 1.0 x 80.0 ft 80.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ftz) Load number (Btuh/ft� °F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross I WP/S Heat I Cool 1 Gross I N/P/S Heat I Cool irl, 13A-40cs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 10A-b 0.970 a 27.16 45.64 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A flocs 0143 S 4 00 2 55 120 9D 36D 229 0 0 D 0 1A h1om 1270 S 35:5$ 0 0 0` 1A cl omd 1270 s 35 56 37 88 D 0 0 0 0 0 0 0 1A hlom a a 1 270 s 35 56 3210 30 30 1067 899 o t3 >0 ,o- �* 1A hlorp i1 27D s 35 56 3210 0 0 0 0 '; 0, 0 D o 1A h1or11 1 270 , 3&86 28;89 Q Q .° 0 ` 0 0 =-0 7fl ha'otizd a _ •:, 1:`270 ,';S s 35 56 _' 28:99. 0. _0... ,...0 0 ._ __ 0 -,- � ,o 13A-40cs 0.143 sw 4.00 2.55, 45 30 120 76 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-h1om 1.270 sw 35.56 55.03 15 7 533 654 0 0 0 0 1A hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 13A 4ors 0 143 w 4 D0 Z 55 11 D 78 , 312 199 0 0 D U 1A h1pc)� 1270 w 35 56 69 p2 0 y; 0 0 0 + D ; 0 0 Q, 1Ah1omd 3 1270 :w 35:56 p6902 '- 0 0 0 0. 0: d 0 0 1Aclomd ` 1.270'�w 3556 91:12 0 0 0 0 0 0 0 0 1A h1o(n , 1 270 .uv 35 56 69.02 32 t q 1 1138 2169 0 ° 0 0 t}s 1A-tilom -'1270 w 3556 69;02 0 0 0 0 0 'u 0 0 tiA` cl omd 1 270 w 0 0 0 Q 0 0 0 0 1A h]orn _.,....i..._ , M.1270 w... _ 35:56 ...<,.,6212 __,..,...>0 0 ..... . 0 n _=: z ..,0 ,.:i 0', w.. ... L-�Oi 13A flocs 0.143 nw 4.00 2.55 45 30 120 76 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 15 0 533 820 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0_ 0 0 0 126 0sW 0 097 - 2:72 1 5/ 0 0 _ 0 0 -- 0 ,0 0 � 0 13A-40cs 0143 - 4.00 1.49 0 0 0 _ 0_ 0 0 0 0 168 30adx,„ _ 0.032 - ___ 090 _ 1 6,8.25,6. __,u:.256, 229 _ 430 _, 80 L .�.y...L,.80 w .72. 99A-tnh 1 R5R - RR n9 n nn n n D D o 0 0 0 61 c) AED excursion 1 1332 -23 Envelope loss/gain 4974 7240 527 422 12 a) Infiltration 613 176 120 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 2100 0 0 0 0 Subtotal (lines 6 to 13) 5588 7646 647 457 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5588 7646 647 457 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 5588 7646 647 457 Air required (cfm) 317 348 37 21 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsoft Right -Suite Residential6.0.101 RSR21889 2007-Aug-3009:56:13 /Ciffp. C:1Documents and SettingsWoe ComerWy Documents%Wrightsoft HVAC 81GROZA107GROZA-williams.rrp Cal Page 14 _ Right-J Worksheet Job: 06549 Zone 2 Date: 8-30-07 PERFECT COOLING INC. By: J.S. 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area guest cl 0.0 ft 10.0 ft heat/cool 1.0 x 70.0 ft 70.0 ft' stairs 3 11.5 ft 10.0 ft heat/cool 1.0 x 150.0 ft 150.0 ft' Ty Construction number U-value (Btuh/ft2�- °F) Or HTM (Btuh/ftz) Area (ft) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross I N/P/5 I Heat I Cool Gross N/P/S Heat I Cool 111 ocs 0.143 a 4.00 2.55 0 0 0 0 90 78 312 199 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 12 0 427 813 1A hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A 4o4s �� 0 143 s 4 OD �3856 2�55z s 0 0 0 r 0 0 0 a¢r 1¢" 1%1h1om 1270's '1270 3210 0 0 0o 0b 0 ti 1Aclomd s 35g56 3788 0¢ f'0 0 0 0 0 D ¢f hlom 1270 s 3556 3210 0 0 0 * 0 0D An ,I 127D 35�a6 3210 D, A 0 �v� ��0s0 r 1A h10m 1270 S{ a 56 28.89 r 0 D 0 0 0 ,35 ,,.L n=. 0_ p MILO, � 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 .0 _,�. 0 IA-hiom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-hiom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A hiom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 13A 0,143w 4oD 255 D a 00 (0 0 0 0 0, Al hiom r 1"270 w s r 35 56 69 D2 D D 0 xr 0ax 0 0. 1A hlornd 1270 rV 36 56 6942 ig a 0 a 0 0 iA clorpd w 35 56 91 12 0 0 x 0 0 D t7 ; 0 0 lA hiom r 127D W 35 56 69 02 0 0 0 ¢ a` 0 o 0 0 1A61Oftr'120 VY 35$6 69Q2 0 0 3 0 fi 1A-c1oifrd' 1270 uu 35.56 TM 8201 P 0" `, 0' 0 D 0 9 0 0 riA h1am z� .3� 3556.. <..6212 <. _ x..a.0. _ 0H. 0.. - .0 -Vm ... x.0.w� __.0 �°0 �._., v.:¢ 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-h1om 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A hlom 1 270 nw 35.56 54.67 0 0 0 0 0 0 0 0 126-0 w 0 097= 2 72 1570 z3 0 0 0 I 11.R0 0,3,90Z -.z 9.;31_ s0 Q Q a LLL 0 0, U 0 0 1434 00 1 49 �. 0 0 0 0 ,.,.:..�.�,._. 0 ..,.�,k 0 _.�.,...� sµ,� 0 ._,,.,.: _,.�w�-D;13A-4ocs 0 16B 3Qad_ - �._i,<fi8_ J<0. ...:,,." 70,.. 22A-tnh a5a _ ast rn n nn n n n n n n 6 c) AED excursion -111 29 Envelope loss/gain 63 107 873 1293 12 a) Infiltration 0 0 120 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 0 0 0 Subtotal (lines 6 to 13) 63 107 993 1327 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 63 107 993 1327 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 63 107 993 1327 Air required (cfm) 4 5 56 60 • Printout certified by ACCA to meet all requirements of Manual J 8th Ed • + wr�ghtsO�C Right -Suite Residential6.0.101 RSR21889 2007-Aug-3009:56:13 AC A7 C:1Documents and SettingsWoe ComerWy Documents%Wrightsoft HVAC 81GROZA107GROZA-williams.rrp Cal Page 15 I Right-J Worksheet zone 2 PERFECT COOLING INC. Job: 06549 Date: 8-30-07 By: J.S. 1 Room name • loft 3 great room 2 2 Exposed wall 22.0 ft 29.0 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 411.0 ft 0.0 x 0.0 ft 5 Room area 411.0 ftz 0.0 ft, Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/fV-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Coal 1 Gross NIP/S Heat I Cool I Gross I N/P/S Heat I Cool 13A-40cs 0.143 a 4.00 2.55 0 0 0 0 70 55 220 140 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A hlom 1.270 a 35.56 69.02 0 0 0 0 15 0 533 1017 �� 13q floes 0143 4 QD 2 55 n 0 0 �, D 0 776 0 Q� , 1Ahlortt 1270 :s 3556 3210 0 D 0 0 '.3 r 0 0 0, q' 1A c1omd ' 1 270 s 35 56 37 88 0 0 0 0 0 0 0 0 Al, Mort `� 1 270 s 35-56 3210 ; j0 0 0 0 D 0 �0 0: lA hloitt �r' o ' 1 27D S 35:56 3210 00 0 0 0 '0 1A h1bm 1 270 fl 35;56 , .. 2889 0 0 0 0 : =0 0 0 0. 1A h3ornd- 1 27D. I_u. 0' 13A-40cs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 IA-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 13A-40cs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 097 .,ti- 212 157 0 D 0 0; 0 -0 0 0 1IDU __=039,0' e_ 1092 1;fl31_ 0 1.49 0 0 0 0 0 D 0 0 13A-4ocs 0 143 4.00 16,E_30ad 4.032 _, _ 0 90_ 4s68„ _411_ w > 41�_ 368 690, w80U _ 660 538, _ 1908 99A-fnh 1 35R - 3R n9 n nn n 0 0 0 0 29 1103 0 61 c) AED excursion 1 1379 1 1 -211 Envelope loss/gain 3142 6543 4221 3336 12 a) Infiltration 293 84 387 111 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 0 0 0 Subtotal (lines 6 to 13) 3436 6627 4608 3447 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3436 6627 4608 3447 15 Duct loads 1 0% 0%1 0 0 0% 0%1 0 0 Total room load 3436 6627 4608 3447 Air required (cfm) 195 301 261 157 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsoft Right -Suite Residential 6.0.101 RSR21889 2007-Aug-3009:56:13 C:\Documents and SettingsWoe Comer\My Documents\Wrightsoft HVAC S\GROZA\07GROZA-williams.rrp Cal Page 16 Right-1 Worksheet zone 3 PERFECT COOLING INC. Job: 06549 Date: 8-30-07 By: J.S. 1 Room name zone 3 LEFT WING 2 Exposed wall 118.0 ft 49.0 ft 3 Ceiling height 6.5 ft d 8.5 ft heat/cool 4 5 Room dimensions Room area 998.0 ft' 1.0 x 380.0 ft 380.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ftj Load number (Btuh/ft;"F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool i Gross I N/P/S Heat I Cool Gross WP/S Heat I Cool 6 13A-40cs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 0 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 1A hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 13A�tocs i 0143 s 4flD 3 2 85 255 169 a677 r 430 170 140 561 356j 1A ttjOm f1 270 s5 35 56 32.10 0 0 p , 0 0 ak 0 0 0 1Ac10ntld 3 ,I1 1270 s� 3556 3` 3788a 0 1Ahlorrt lzto sz 3556 3210 o Q Dig �D a o Q 1Ah1om' 127Ds 3556 32100 0 0 0 0 g * 0` 00 1 270 s 35;56 28=89 30 0 r,-1067 �887 1 3D 1A h0ind_: -:4�270s3556 13A-4ocs 0.143 sw 4.00 2.55 72 42 168 107 36 21 84 53 1A-hlom 1:270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 D 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 0 0 0 0 1A hlom 1.270 sw 35.56 55.03 30 0 1067 1651 15 0 533 825 13A-4ocs ;0143 vV 4OD 255` 357 159 637 405 85 - 55 22D 140 lAhlom 1270 w 3556 F9Q2 C 0 g 0 p Q p #0k Q 0, y 1A h1omd € 1 270 w 3556 6902 0 0 0, 0 r 0 0 0 0 1A�1omd 1270 w 3556 9112 0 0 0 0 0 0 0 1A h1orir f� w a35 S6 0' �0 k 0 0 1A h10m 1270 w 35 56 69 02 30 0 1067 tt 20 .1 3 30 U 106T 2071 1A�1o_ind� 1270 w 3556 8201 56 �f 56" L 1?53 0 0'0 Q 1A=hloin�u..�m 7.27Q mwL ��35156 z 62€12 � � ,..'t12 ...... � 1.17 �1991 .ate .�3983 �h 1 A0.1.9 . , .....�D � ._.�,,..0 _ � � 0 13A-4ocs 0.143 nw 4.00 2.55 74 44 176 112 38 23 92 59 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 IA-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A-hlom 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1A hlom 1.270 nw 35.56 54.67 30 0 1067 1640 15 0 533 820 126-0SyS� A 097 a 22 a 5D4 r , 46D 1249 723 -9 128' s 128 ,- 3 a� � r 20` 0,3.9Q 1U:92 11c31_,,,k. 44 3, E348 13A 0 143 _ - 400 1.49 ,, 110 110 440 164 110 110 440 164 1.877_,,:38p.'.,..,s_._.::�84���3.40,.,,�s�$i 22A-tnh 1.35R - 3R 1717 n On 99R 11R ddR7 n 3Rn dQ 1RR3 n 61 c) AED excursion 17605 1735 Envelope loss/gain 25088 27011 9237 8500 12 a) Infiltration 1321 379 545 156 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 1 2075 0 1029 Subtotal (lines 6 to 13) 1 26410 29465 9782 9685 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution, 0 0 0 0 14 Subtotal 26410 29465 9782 9685 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 26410 29465 9782 9685 Air required (cfm) 13391 13391 496 440 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�g h tso1TC Right -Suite Residential 6.0.101 RSR21889 2007-Aug-30 09:56:13 �_K C:\Documents and SettingsUce Comer\My Documents\Wdghtsoft HVAC 8\GROZA\07GROZA-williams.rrp Cal Page 17 Right-J Worksheet Job: 06549 zone 3 Date: B-30-07 By: J.S. PERFECT COOLING INC. 1 Room name RIGHT WING CENTER 2 Exposed wall 47.0 ft 22.0 ft 3 Ceiling height 8.5 ft heat/cool 0.0 ft heat1cool 4 Room dimensions 1.0 x 380.0 ft 1.0 x 238.0 ft 5 Room area 380.0 ftz 238.0 ftz Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load number (Btuh/ft? *F) (Btuh/ftZ) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 1r.M., 13A-40cs 0.143 a 4.00 2.55 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 10A-b 0.970 a 27.16 45.84 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 1A-h1om 1.270 a 35.56 69.02 0 0 0 0 13A 4as 0143 s 4 UD 255 85 " 29 116 w ' 74 1A hlotn - 1 270 s 35,56 32,100 0 ❑ 0 1A clomd 1 270 s 35;56 3788 r 0 0 0 0 1A ►iloin 1 270 's 35 56 3210 0 0 0 0 1A h10 ri - 1 276 Z10 0 0 0 0 1A hlom 1,270 s 35:56 28:89 0 D 0 1iA ilond 70 ts_Z.,,3558 56. LE 56, 53 13A-4ors 0.143 sw 4.00 2.55 36 21 84 1A-hlom 1.270 sw 35.561 55.03 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 1A-hlom 1.270 sw 35.56 55.03 0 0 0 0 13A4ocs 1A-h1om 1A-hl om 1A-hlom 0 0 0 0 0 0 0 0 0 0 0 0 _fit 0 0; 0 0 0 0 0 b 0 0 0 0 0 0 0.143 nw 4.00 2.55 36 21 84 53 0 0 0 0 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1.270 nw 35.56 54.67 0 0 0 0 0 0 0 0 1.270 nw 35.56 54.67 15 0 533 820 0 0 0 0 tl 097 ;- 272 1"$7 96 ` 196 532 308 ; 180 ° 138 369 214' 0 39.0 -fie_ ._.:•1Q92 _ 11,31E _ Q .,_.._ _ Q ' 0. 0.143 4.00 1.49 0 0 0 0 0 0 0 0 0 032 6190 168 w 3,80, 38D _390, - 638 239; r , 236.213 400' �SR _ qa'7 n n nn Zan d7 17a7 n 9 to 99 aa7 n 61 c) AED excursion 12858 1 1 4012 Envelope losstgain 9669 10178 6183 8334 12 a) Infiltration 527 151 249 72 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 2100 0 1046 0 0 Subtotal (lines 6 to 13) 1 10195 11375 6432 8405 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 10196 11375 6432 8405 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 10196 11375 6432 8405 Air required (cfm) 517 5171 1326 1 382 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrrtghtsoft Right -Suite Residential6.0.101 RSR21889 2007-Aug-3009:56:13 AC�GA C:1Documents and SettingsUoe ComerWly Documents\Wrightsoft HVAC MROM07GROM-williams.rrp Cal Page 18 FIREPLACE FACTS Standard 42-Inch radiant (NVBR) or heat circulating model (NVBC) gas fireplace. FEATURES: • 42-Inch Wide Firebox Opening • Patented Ceramic Burner System • CSA Design Certified • Factory Built Design for Simple Installation With 6" B-Vent • On/Off Wall Switch • Real Firebrick Liner • Fuel Conversion Kit Available • Factory Installed Spill Switch • Patented Insta-Flame Ceramic Burner System •Limited Lifetime Warranty BURNER SYSTEM: • Capacity — Natural: 30,000 BTU/HR Max. 21,500 BTU/HR Min. — Propane: 30,000 BTU/HR Max. 22,000 BTU/HR Min. • Fuel - Natural or Propane Gas • Ignition System - NVBR42(R)/NVBC42(R): Standing Pilot With Piezo Ignitor, A Low Voltage (mV), Self -Generating Power Pile System - No outside Electrical Power Needed - NVBR42(E)/NVBC42(E): Electronic Ignition That Requires 120 VAC Electrical Hook up • Gas Supply Line - Consult Gas Code Book for Correct Sizing • Inlet Gas Supply Pressure Natural Propane Minimum Inlet Pressure 5.5" w.c. 11.0" w.c. Maximum Inlet Pressure 14" w.c. 14.0" w.c. Manifold Pressure 3.5" w.c. 10.0" w.c. MINIMUM FLOOR AREA: • 47" W X 201 /2" D HEARTH EXTENSION: A Hearth Extension Is Recommended But Not Required OPTIONAL ACCESSORIES: • AK -MST - Outside Air Kit Termination - 4" Rd. Class 1 Duct (Not Supplied) - 40 Ft. Maximum Run - Maximum (2) 90° Elbows or (4) 45° Elbows (Not Supplied)* • AK -MST - Outside Air Kit Termination (includes collar and cap) • SCVS - Speed Control Variable Speed (NVBC42 only) • FK12 - Fan and Cord (160cfm) (for RN/RP only) (NVBC42 only) •TV0617 - 6" Thermal Vent Damper for Decorative Gas Appliances vented with 6" B-Vent • NV42TKS - Window Screen Kit • EB1- Electrical Box (required for fan installation) (NVBC42 only) • RC1 - Remote Control, On -Off w/ Batteries • RC2 - Remote Control, On -Off w/ Batteries • Wood Mantels and Mantel Shelves (See Mantel Section) - Minimum clearance above fireplace opening (See Installation Manual for Details) • Not to be used in Canada. GLASS DOORS 42GSKBB Single Panel - Brushed Brass 42GDKBB Standard Bi-fold Brushed Brass w/ Black Track 42GDKBK Standard Bi-fold Black w/ Black Track 42GDKDP Standard Bi-fold Polished Brass w/ Black Track 42GDKS Standard Bi-fold Pewter w/ Black Track The Fireplace Facts Information Sheets are for quick reference only and are subject to change without notice. Actual fireplace Instructions must abide by specifications provided with each product AJESTIC REV.11/06 6"Type-B Gas Vent (Individual Vent System Only) SPECIFICATION: •6"I.D. • 1" Clearance to Combustible Materials MINJMAX. INSTALLATION.HEIGHTS: • Minimum vertical chimney height -12 Ft. (3.65m) • Maximum vertical height - 40Ft. (12m) • Minimum height with two elbows -16 Ft. (4.06 m) • Elbow requirements elbow a maximum of two 90 degree elbows or four 45 degree elbows per installation. ( Two 45 for proper elbow offset runs. Venting Runs Horizontal Run (in feet) 1 2 3 4 5 6 7 8 910 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 d w C r ❑ = Acceptable venting configuration = Unacceptable venting configuration a tv. �.z" ;a "kF it i 77 A: Vertical installations up to 40 feet (12m) in height. Up to a 6 ft. horizontal vent run can be installed within the vent system using a maximum of two 90-degree elbows or four 45-degree elbows. B: Vertical installations up to 40 feet (12m) in height. Up to a 10 ft. horizontal vent run can be installed within the vent system using a maximum of two 45-degree elbows. ANSI Z21.50b-2002/CSA 2.22b-2002 Vented Gas Fireplaces This gas appliance should be installed by qualified installers in accordance with local building codes and the current National Fuel Gas code ANSI Z223.1 or CSA B149.1 Installation code for Gas Burning Appl'fance and EquipRenL FP567 A I N N CD C �_ N CCDD C ❑ O N -�. . = O O II II CL] CS =r Al CD ^ pOj (0 cr 3 C' N CD pnj C 3CD-v� A °i3w-D� :3n CD Co X N A7 0 D— p w COD 3 U cc 3 (D s Cr c CL N tD O O_ -+ �. a1 07 CD O X :3 CD O O 6CCDD -� O C CT — _� O < O 7 0' "O =. O g 'O CD O O' O (n O 35. O = (!? 4 CD N N C)l < 3 p CO W N 4 O< 0 O O n CD 0 �, 0 CD (D r CD N (D O 7 =� Cfl ^ w Cp CD `< CD CD < CD ^ CQ ET3 3 CD a 3 3 0 O 3 O T C 5• O C 7 Cn V p Co w Vertical Run (in feet) a,. e t . p IOU LLL2LA MAN, � x r"R a t °3 4 .y.,y .V7 _ aO aDW W V 4 W MfltAA W NN�s OV [WDN V N (A7tAN� W W e00j tOA�NUnOAO N QeO Q�mA W N 'a °aaa 'a a a a r3a a a s m M J J 0 C)-0 010 0 n 01oo000o0 00 ,3_ -�0000�o�o�00000000+00000-�ooioo �? �: M 0 C4 �[(n woo "WNN00--+ON-a-aNOi00001-+000000 A r! O NAA W NN O[D aO IDm V V O) W [nA A W NN-+ O[O0 W (p N ()n0 W Wj�O A aDA O) NAON N NOS O l CO N O, OA T W a R a +a° °a 'a 'a a s S 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .�i J � 000 s 00-+000000-+00� 000000 s � O � 00 N .di 0100 N 0011300-+00-+N0O NOO-+-+000000 W m ID 0 0 " 0 00000-+001000000100 AO A A 00 A A a O O fnONOAfJA (nA ALJ7AAAA W AA W W A W O W 00 W W O N N FIREPLACE AND VENTING SPECIFICATIONS MIIIIIIIIIIIIIII Rough I� 28" (711 mm) ►I Opening 17 49"L (1245mm) Depth 6" DIA. 1/L" 13mm 201/2" 83/e" (521 mm) (213mm) 20" + (508mm) s/e Recessed ® ® (16mm) Nailing ® 1 I_ Flange E 51/a" (895mm) `�6�1 r Rough Opening Width 47"►I� g a e foh Opening V; N Height. Wyl 71/z" 36" 401/z' — — — _ — — (191mm) (914mm) (1029mm) - T Outside N E m Air �'of 71/z" 42" n W91mm) (1067mm) Gas Line rn M� AccessElectrical 14" — — — — — — 7��„ i o Access _ (356mm) _ _ _ _ _ _ (191 mm) - /a" ► 38" (965mm) I-o 131—� I J (337mm 3" 46" (1168mm) —y 2' 6Yz" 3' (76mm) (51mm) (165mm) (76mm) Drawings not to scale VENT SECTIONS 1 OFFSETTING ELBOWS I I I I I I 581 /2. 46vz" -4-- 63i4" T 341i2" 1 I —� I 161rz" I I 101/2" � T NOTE: THE INSTALLED LENGTH OF ANY VENTING SECTION IS 11/211 LESS THAN ITS TOTAL LENGTH, EXCEPT FOR THE LAST SECTION INSTALLED. r SOUTHEAST ELEVATOR,-INC® i 1 I Home About Us Cab Designs ! Options I Contact TANDARD FEATUREIS This specification represents our standard pre-engineered residential elevator system. Many different options and configurations are available to suit specific needs. Please contact us to discuss your special requirements. Gate Select Colors Standard Residential Elevator Outline Specifications: Fixture Lighting TYPE Hydraulic CAPCITY 750# SPEED 40 FPM TRAVEL 50' Maximum PLATFORM 38.75" x 49.50" SHAFT 52" x 54 PIT 12" OVERHEAD 8'0" Minimum LANDINGS 5 Maximum CAR OPENINGS 1 to 3 DOOR SIZE 36" x 80" or 36" x 96" DOOR TYPE Swing OPERATION Automatic POWER SUPPY 220 Volt, 1 Phase, 30 Amp 120 Volt, 1 Phase, 15 Amp {' CAB WALL FINISH 3/4" Oak, Cherry, Mahogany, or Maple Veneer GATE TYPE Scissor CEILING FINISH 3/4" Standard White ,. HEIGHT. 81" or "96" HANDRAIL Hardwood • ' FLOORING BY OTHERS LIGHTING Standard Recessed with Auto Lighting FIXTURES CART STATION 1 -HALL-STATIONS 1 per landing TELEPHONE R Wall Mount Jack FISNISH Stainless Steel CONTROL CONTROLLER PLC/ Relay LANDING Tape Selector/Limits PUMP Screw Pump VALVE Two Speed, Four Coil EMERG. LOWER Standard - INTERLOCKS EMI GATE OPERATION Manual DOOR OPERATION Manual Topes" Home I About Us I Cab Designs ( Options I Contact p. 2007 Southeast, Elevator, Inc. All Rights Reserved NOTE..38.75 'j r� SEE 11 NOTE LU 49.5011 0 LU 27 27 Hai LH —RH — �EE �EI DOOR 3E" 3E" DOOR INSIDE FINISHED 5211 52" INSIDE FINISHED ISHED NOTE: RAIL WALL SOUTHEAST ELEVATOR, INC. I) IF BLOCK POUR CELLS SOLID 905 WAGNER PLACE 2) IF FRAME SEE SHEET S-12 FORT PIERCE, FL 349E2 772-461-0030 T ND DIMENSIONS FOR LH AND RH PAGE 1 0 T t BRACKET TYPICAL 7' . BRACKET TYPICAL 7t BRACKET TYPICAL 71 4 7 611 611 611 Got TYPICAL FASTENING: VV00D STUD: 5EA, 1 f2" X 3.25" LAGS TRAVEL SOLID BLOCK: 3EA. I " X 3.75" WEDGE ANCHORS SOUTHEAST ELEVATOR, INC. PIT 905 WAGNER PLACE 12" FORT PIERCE, FL 34982 772-461-0030 PAGE 2 EQUIPMENT LAY FRONT 'CIE' 1 E"X 1 B"X131E CONTROLLER PUMP UNIT 22"X22" 24" MIN. I 4 9 1 ) 220u 30AMP ,narH raEAurRa.L AND otsCoNNEct FOR purer Moror 2) 14 C1V 15AMP DISCONNECT FOR CAB LIGHTS 3) TELEPHONE LINE NOTE: PIPING AND Vt4RE FROM DISCONNECTS TO CONTROLLER PROVIDED BY ELECTRIC,4N, SOUTHEAST VNLL TERMINATE F 1 E" l 6"'XE 2L"x22i1 PUMP UNIT TOP VIEW SOUTHEAST ELEVATOR, INC. 905 WAGNER PLACE FORT PIERCE, FL 349E2 772-4E1-0030 FADE 3 LANDING DOOR ELEVATOR DISTANCE NOT TO EXCEED 511 DISTANCE NOT TO EXCEED 3" TYPICAL LANDING DOOR DOTE: PAY ATTENTION TO DOOR OFFSET DIMENSION AILS PER CODE ALL FLOORS 114" FLAT TRIM INSIDE SHAFT SOUTHEAST ELEVATOR, INC. 905 WAGNER PLACE FORT PIERCE, FL 34982 772-461-0030 IMAGE 4 PLyvvooD NAIL WALL r MOTH OF 1. RAIL WALL START AT RAIL CAL ON RAIL WALL VWTH STUD 2X4 MIN. VWJRK OUT 6" ON CENTER fN-LfNE TOP TO BOTTOM 41— 314°° EL K')0D L)IRECTLY ON VA�OD STUDS FROM TOP TO BOTTOM = OF RAIL WALL ONLY, NAILED OR SCREVVED EVEN l' 6" TO 11 m SOUTHEAST ELEVATOR, INC. I' 905 WAGNER PLACE FORT PIERCE., FL 34982 772-461-0030 SHEET S-12 M LAS TORTUGAS AT HUTCHINSON A SUBDIVISION IN DEDICATION: STATE OF 99h" COUNTY OFCY_7A_W_0f_A KNOW ALL VEN BY THESE PRESENTS, that V L Properly Ventures, Ltd., on Ohio Limited Uot•Tty Company registered to do business in Florida, as V L Property Ventures, L; L, U.C. owner of the lands shown and described hereon as Los Tortugas al Hulclninson Island has caused the some to be surveyed and platted as shown hereon and does hereby dedicate the lands as follows; 1. TRACT A shown hereon is hereby dedicated to the Las Tortugas at Hutchinson Island Home Owners Associatlon, Inc. for (a) Ingress and egress to State Road A-1-A b) installation and maintenance of drainage facilities and (c) all ulilit f purposes by any ulgily (including coblevisiol ) hi compliance with such o,dinances and regulations as may be adopted from time to time by the Board of County Commissioners of St. Lucie County. 2. UTILITY EASEMENTS as shown or dedicated herein may be used for ulgity purposes by any utility (including cablevision) in compliance with such ordino-es and regulations as may be adopted from time to time by the Boa,d of County Commissioners of St. Lucie County. 3. A DRRKIAGE EASEMENT as shown herein Is hereby dedicated to the Las Torlugr:s at Hutchinson Island Home Ownners Association. Inc. for the inetc'lation and maintenance of drainage facilities and the perpetual maintenance of the bulkhead and Is the maintenance obligation of said Las Tatugas at Hutchinson Island Home Owners' Association Inc., Its successors and/or assigns. 4. A PEDESTRIAN ACCESS EASEMENT as shown herein is hereby dedicated to the Las Tolugas at Hutchinson Island Home Owner's Association, Inc. for access and is the maintenance obligation of said Las Tortugas at Hutchinson IslandHorne Owner's Association, Its successors and/or assigns. 5. WALL EASEMENT as shown herein Is hereby dedicated to the Las Tortugas at Hutchinson Island Home Owners Association, Inc. for the installation of and maintenance of a privacy wall and is the obligation of the Las Tortugas at Hutchinson Island Home Owners Association. its successors and/or assigns. 6. the PRESERVATION AREA EASEMENT as shown herein is hereby dedicated 'to the Las Tortugas at Hutchinson Island Home Owners Association, Inc. for the preservation of existing vegetation. No cleaning, trimming or removal of any vegetation protected by the St. County Land Development Code, Section 6.00. shall be done so without written permission of said SL Lucie County. 7. THE CCIISERVATION AREAS (CA), AS SHOWN HEREON, ARE HEREBY DEDICATED AS CONSERVATION EASEMENTS TO THE LAS TORTUGAS AT HUTCHINSON ISLAND HOME OWNERS' ASSOCIATION, INC. A FLORIDA NOT FOR PROFIT CORPORATION, THEIR SUCCESSORS AND/OR ASSIGNS. PORTIONS OF THIS PLAT PERTAINING TO THE CONSERVATION AREAS OR RESTRICTIONS SET FORTH BELOW PERTAINING TO THE CONSERVATION AREA, SHALL NOT BE AMENDED, REVISED, REUNQUISHED OR REVOKED YATHOUT PRIOR WRITTEN CONSENT OF THE LAS TORTUGAS AT HUTCHINSOII IRIS' AND HOME OWNERS' ASSOCIATION, INC.-IT,IS THE PU8%.SE OF THESE RES IRICTIONS TO RETAIN LAND OR WATER AREAS:.SEY FDRTH.0)j.�TI CONSERVATION AREAS IN THE] NATURAL VEGETATIVE, H ROCr161Ci.S IC, OPEN, AGRICULTURAL OR WOODED CONDITION AND TO Ft�t IN "$UGH^ CONSER. ANON AREAS AS SUITABLE HABITAT FOR FISH, PLANTS'OR'NIDLIFE THOSE WEII.AND AND/OR UPLAND AREAS INCLUDED IN THE RESTRICTION WHICH ARE TO BE ENHANCED OR CREATED PURSUANT TO THE PERMIT SHALL BE RETAINED AND MAINTAINED IN THE ENHANCED OR CREATED CONDITIONS REQUIRED BY THE PERMIT. TO CARRY OUT THIS PURPOSE, THE FOLLOWING RIGHTS ARE CONVEYED t0 THE LAS TORTUGAS AT HUTCHINSON ISLAND HOME OWNER'S ASSOCIATION, INC.:TO ENTER UPON THE PROPERTY DESCRIBED ON THIS PLAT, TO ACCESS CONSERVATION AREAS AT REASONABLE TIME- Tr ENFORCE THE RIGHT HEREIN GRANTED IN A MANNER THAT WILL NOT UNREASiNABLY INTERFERE NTH THE USE AVID QUIET ENJOYMENT OF THE PROPERTY, BY THE GRANTOR AT THE TIME OF SUCH ENTRY, AND TO ENFORCE ANY ACTIVITY ON OR USE OF THE CONSERVATION AREAS THAT IS INCONSISTENT NTH THESE RESTRICTIONS AND TO ENFORCE 1! It RESTORATION OF SUCH AREAS OR FEATURES OF THE CONSERVATION AREAS THAT MAY BE DAMAGED BY ANY INCONSISTENT ACTIVITY OR USE EXCEPT FOR RESTORATION, CREATION, ENHANCEMENT, MAINTENANCE AND MONITORING ACTIVITIES, OR SURFACE WATER MANAGEMENT IMPROVEMENTS, WHICH ARE PERMITTED OR REQUIRED BY THE PERMIT, THE FOLLOWING ACTIVITIES ARE PROHIBITED IN OR ON THE CONSERVATION AREAS: CONSTRUCTION OR PLACING Or BUILDINGS. ROADS, SIGNS. BILLBOARDS OR OTHER ADVERTISING UTIU TIES OR OTHER STRUCTURES ON OR ABOVE THE GROUND; DUMPING OR PLACING Of SQL OR OTHER SUBSTANCE OR MATERIAL AS LANDFILL, OR DUMPING OR PLACING OF TRASH, WASTE OR OTHER UNSIGHTLY OR OFFENSIVE MATERIALS; REMOVAL CR DESTRUCTION OF TREES, SHRUBS OR OTHER VEGETATION, EXCEPT FOR THE REMOVAL OF EXOTIC OR NUISANCE VEGETATION IN ACCORDANCE NTH AN APPROVED MAINTENANCE PLAN; F%CAVATIOIL DREOGIHG OR REMOVAL OF LOAM. PEAT. GRAVEL SOIL. ROCK OR OTHER MATERIAL SUBSTANCE IN SUC SURFACE USE EXCEPT FOR PURPOSES THAT MANNER AS 70 AFFECT THE SUHFAGt; U POSES AT PERMIT THE LAND OR WATER AREA TO REMAIN IN ITS NATURAL CONDITION; ACTIVITIES DETRIMENTAL TO DRAINAGE, FLOOD CONTROL. WATER CONSERVATION, EROSION CONTROL, SOIL CONSERVATION OR FISH A14D WILDLIFE HABITAT PRESERVATION INCLUDING, BUT NOT LIMITED TO, DITCHING, DIKING AND FENCING; ACTS OR USES DETRIMENTAL TO SUCH AFOREMENTIONED RETENTION OF LAND OR WATER USES; ACTS OR USES WHICH ARE DETRIMENTAL TO THE PRESERVATION OF ANY FEATURES OR ASPECTS OF THE CONSERVA1ON AREAS HAVING HISTORICAL OR ARCHAEOLOGICAL SIGNIFICANCE. THE FOLLOWING RIGHTS ARE SPECIFICALLY RESERVED TO THE GRANTOR, ITS SUCCESSORS AND ASSIGNS, TO THE EXTENT PROVIDED BY LAW. PROPERTY OWNER'S Or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nERAL, STATE OR LOCAL PERMIT AUTHORIZATIONS OR SOVEREIGN LAND APPf(OVALS FOR CONSTRUCTION OF THE DOCKS OR BOARDWALKS. PLANS FOR THE CONSTRUCTION OF DOCKS AND BOARDWALKS SHALL BE APPROVED BY THE S.F.W.M.D., SINCE THERE ARE NAVIGABLE WATERS IMMEDIATELY ADJACENT TO THE EASEMENT AREA, BOATS AND OTHER SIMILAR SURFACE USES ARE PERMISSIBLE WITHIN THE NAVIGABLE AREAS OF THE EASEMENT. NO RIGHTS OF ACCESS BY THE GENERAL PUBUC TO ANY PORTION OF THE PROPERTY ARE CONVEYED BY THIS EASEMENT. . THIS EASEMENT MAY BE AMENDED, ALTERED, RELEASED OR REVOKED ONLY BY WRITTEN AGREEMENT BETWEEN THE PARTIES HERETO, THEIR SUCCESSORS AND/OR ASSIGNS. SECTION 34, TOWNSHIP 36 SOUTH, ST. LUCIE COUNTY, FLORIDA MORTGAGEE'S CONSENT THE LAS TORTUGAS AT HUTCHINSON ISLAND 110ME OWNERS' ASSOCIATION, INC., A FLORIDA NOT FOR PROFIT CORPORATION, I1S SUCCESSORS AND/OR ASSIGNS, RESERVES ALL RIGHTS AS OWNERS OF THE PROPERTY INCLUDING THE RIGHT TO ENGAGE IN USES OF THE PROPERTY THAT ARE NOT PROHIBITED HEREIN AND WHICH ARE NOT INCONSISTENT WITH ANY DISTRICT OR COUNTY RULE, CRITERIA, PERMIT AND THE INTENT AND PURPOSES OF THESE RESTRICTIONS. OFF ROAD VEHICLES, HEAVY EQUIPMENT OR OTHER VEHICLES SHALL BE PROHIBITED FROM ENTERING THE EASMENT AREA WHICH THESE RESTRICTIONS COVER UNLESS THE FERMITIEE HAS RECEIVED WRITTEN APPROVAL FROM S.F.W.M.D. THE MAINTENANCE AND MONITORING OBLIGATION OF THE EASLCENT SHALL BE A PERPETUAL OBLIGATION OF THE LAS TORTUGAS AT HUTCHINSON ISLAND HOME OWNERS' ASSOCIATION, INC., THEIR SUCCESSORS AND/OR ASSIGNS. IN WITNESS WHEREOF, V L Property Ventures, Ltd., an Ohio limited liability company. registered to do business in the Stole of Florida under the name V L Properly Ventures, Ltd., LLC., has caused this instrument to be signed by its undersigned President. and Manager with full knowledge and consent of Its members this day of hW -- 2004. BAI y. a. 9. 6 Wbeseed: , Name• Cary 101bor NA(JD ' F ANTL President d Manager Printed Name: 7)N Will- ssed: •� K4. �uL_ Printed Name: SHv,Tyw �. df b•r ACKNOWLEDGMENT: STATE OF +rQ COUNTY OF GLIYr Ift Before me, the undersigned authority. personally appeared Guy Hribar, to in. well known and known to be the individual describb.. in and who executed the foregoing Certificate of Dedication, and :fie duly acknowledged before me that he executed same, a such ofer for and in behalf of sold company. He is personally known fic to me and did not take an oath: Witness my hand and official seal, this Z04day of-219W-, 20D4. By. y Commission Expires: )-2�.-rne•% /)1rw�ct_ Q RwL.c.c rncHAiRrasi.xvarcAcr: xyJrs�n''�eyaI Notary Public (Printed Nome) Nir,++Jd3aAtrzs LEGAL DESCRIPTION STATE OF FLORIDA: COUNTY OFALMIdDI& DQ�: R-0 CROWN BANK , A FEDERAL SAVINGS BANE, 11IE HOLDER OF A MORICAGE RECORDED W O.R. BOOK 1845. AT PAGE 455, AI4D RE -RECORDED IN O.R. BOOK . 1929. PAGE 484. PUBLIC RECORDS OF ST. UD NIY, rLORIDA ON THE ABOVE DESCRIBED LAND, BY ITS DULY ELECTED DES HEREBY JOIN AND 4, 1-e CONSENT TO THE DEDICATIONS AS SHOWN ON THIS LAS IORIUGAS AT HUTCHINSON ISLAND PLAT AND DOES HEPEBY JOIN AND CONSENT 10 114E DEDICATION OF ALL EASEMENTS, AS SHOWN ON 1111S PLAT. IN WITNESS WHEREOF, THE U14DERSICIIED CORPORATION HAS CAUSED THESE IiSD I TIS 4/ybE 614L1 E HERlI�TO TAFFID'.tED �� SR_Tn EADA 0 BE BY 1HjLj OF fM.T _ 2004. R-G CROWN BANK, F.S.B. (F,`K/A CROWN BANK, A Fede,al Sov4,gs Bank) BY: OJLA&�li� PRINT NAME CATM'! SACIIT.w COUNTY ENGINEER: STATE OF FLORIDA' COUNTY OF ST. LUCIE: It 1. hereby caNll.d that this plat meets ail mtninnum subdiNsiw ptaltlnq quiremenis as set forth Is Scott 11.03.00 ill the St. Lucie County Land Development C.4s. • By / ✓WI lehoel Powiey, P.E. County Engineer SL Wcie County. Florida COMMUNITY DEVELOPMENT: STATE OF FLORIDA: COUNTY OF ST. LUCIE It Is hereby cerli0ed that this plot meets the mk,knum lot dimension requbemenbs of the SHIRD z g district as set forth. hi Section 7.04.00 of the s de C n Lana Development Code. By. Randy Intorum Growth Management Director St. Leda County, Florida A parcel of land located on Hutchinson Island In Section 34, Township 36 South. Range 41 East, St. Lucie County, Florida, more particularly described as follows: BEGIN at a point of intersection of the North line of the South 2577.66 feet of the North 2858.86 feet of sold Section 34 and the Westerly right-of-way line of State Road A-1-A; thence ran South 20'23'08r East along said Westerly right-of-way line a distance of 440.0 feet to a point; thence run North 72'24'10. West o distance of 686.20 feet more or less to the Easterly Mean High Water, of the Indian River; thence Northerly along said Mean High Water Line a distance of 215.00 feet more or less to said North line of the South 2577.66 feet of the North 2858.86 feet of said Section 34; thence run North 89'5938' East along said previously described North line a distance of 459.OD feet more or less to the POINT OF BEGINNING. Legal Description supplied by Client TITLE CERTIFICATION . STATE OF FLORIDA COUNTY OF ST. LUCIE I, DAVID N. SOWERBY, A MEMBER IN GOOD STANDING WITH THE FLORIDA BAR, HEREBY CERTIFY THAT AS OF 1 2004, AT &--M AM. (P.M. THAT: 1. APPARENT RECORD TO THE LAND DESCRIBED AND SHOWN ON THIS PLAT IS IN THE NAME OF THE COMPANY EXECUTING THE DEDICATION HEREON. 2. ALL MORTGAGES, NOT SATISFIED, RELEASED OF RECORD, OR OTHERWISE IN BY LAW ENCUMBERING E LAND DESCRIBED HEREON ARE ' TERMINATEDTHE A i FOLLOWS: R-G CROWN BANK , F.S.B., THE HOLDER OF A MORTGAGE RECORDED IN O.R. BOOK 1845. AT PACE 455, AND RE -RECORDED IN O.R. BOOK 1929. PAGE 404 PUBLIC RECORDS ST. LUCIE C NTY, FLORIDA. BY: _ DAVID N. SOWERBY WHOSE ADDRESS IS: MELVILLE h SO BY, P.L. . 2940 SOUTH 25TH STREET FORT PIERCE, FLORIDA 34981 , /n;: •„r ram, f j�co'Yl COUNTY COMMISSION: STATE OF FLORIDA: COUNTY OF ST. LUCIE It Is ..weby certified that this plot has been officially approved for record by the Board of County Commissioners of St Lucie County, Florida, this day o1 //// , 2004. By, r/vr/ Chahmon. Board of 0 rA Commhssianos COUNTY ATTORNEY: STATE OF FLORIDA! COUNTY OF ST. LUCIE: This plot s her by appro as to form. ' By. 5cold S. MdnyrCountya County Attorney COUNTY SURVEYOR: STATE OF FLORIDA: COUNTY OF ST. LUCIE: It Is hereby certified that the undersigned surveyor and m pper duly II.-il In the Slate of norlda has r lvieClwiWlethr h177lot far Sloan with the requirements By County Surveyor St. Lurie County, Florida ;y L County P• as'I� County Surveyor ! Engineer 1 \4 -55?4 ISLAND RANGE 41 PLAT BOOK PAGES EAST, CLERK OF CIRCUIT COURT: STATE OF FLORIDA: COUNTY OF ST. LUCIE. I, Te 4041xIAi4 Clerk of Circuit Court of SL Lucie County, Florida, do hereby eerUfy that this plot has been scrolo,cl and that it carnplies In form with all of the requirements of the laws of Florido pertaining to Maps and Pfats, and that this Plot hen been fled for public Stcord in Plat Book �, Page .t. _i�1_. of the Public Rerorde of . Lucia County, Florida, this �- d y or 2004. By: Wit=::� C), Clerk of Circuit Court St. Wcie County, Florida SURVEYOR'S CERTIFICATE: STATE OF FLORIDA- COUNTY OF ST. LUCIE: I hereby certify that the plat shorn hereon is a true and correct representation of a survey made under my responsible direction and .cri"sion; that said survey is accurate to the best f my knowledge and belief; that Permanent Reference Monuments (P.R.M:s), Permanent Control Points, (PCP's) and lot comers required by law; and further that this plat complies with all requirements of Chapter 177. Florida Statutes. Dated this CP day of ��`, 2DO4. By. Michael T. Owen Professional Surveyor and Mapper No. 5556 SURVEYOR'S NOTES: 1. E3 designates o set Permanent Reference Monument (P.R.M.) with the designation LB 4286 thereon. 2. B designates a set Permanent Controf Point (P.C.P.) with the designation LB 4286 the,eon. 3. The Westerly right-of-way line of State Road A-1-A is assumed to bear South 20'23'08 East as per legal description. All bearings shown herein are related U'iereto. 4. Elevations shown herein are based on the Florida Department of Natural Resources monument 9477 A OB 65 base Elevation 4. 2 don the National Geodetic Vertical Datum of 1929 (N.G.V.D. 1929). 5. NOTICE: There may be additional restrictions that are not recorded an this plat that may be found in the Public Records of this county. B. This plot contains 9 lots. 7. This plat, as recorded in Its graphic form. Is the official depiction of the subdivided lends described herein and will in nocircumstancesbe supplanted In authority by any other graphic or digital form of the plot. There may be additional restrictions that are not recorded on this plat that may be Lsund In the public records of this County. B. Air lines are radial unless otherwise noted. ' PREPARED_Sy- CULPEPPER & TERPENING, INC. 2980 SOUTH 25th STREET -A.,., g'4 FORT PIERCE, FLORIDA 34981 CERTIFICATION NO. LB 4286 '�✓ �K•I WCHAEL T. OWEN ` ��"" PROFESSIONAL SURVEYOR AND MAPPER )':;-?t"•y:it .,; s FLORIDA CERTIFICATE I40. 5556 SHEET 1 OF 2 . _ .. ... ... ..... _..._...., u........... - - .. .. ,�,.• � , '. ', ' (. I 5,., /.. .•.. •• � .• , , art ���' d: I•a' ,\ : , .. ., ',:Lu~ , ;... �11. '1 y'c'Y�' ...t ? .. .. .. ... .:. ..! h .l ;. .. •.• ; ,. l �.' 1r .. .. lj .... I � ..'..`r,. .,,. •�.1 !.. .. � .i: ,ie.et�airT�7lLS�lul(....r 0 a Ljq �5 LAS TORTUGAS AT HUTCHINSON A SUBDIVISION IN SECTION 34, TOWNSHIP 36 SOUTH, ST. LUCIE COUNTY, FLORIDA '_____________ 34 i 35 i I rlq hIN I'mm PAY. Na W59 $r M n CtNSERVATION AREA N g\n U 1 41 1 0.n ACRES I� 1 Na x.l., I 27t NBI76']I'W 10{f S02'OV4?7E 32.09 I Z Q �' pl R O oI - s a27 ACRES Z I n�ry rn/ CCN AREA ARG 36' ) / N7274}pw APPROL EASTERLY MEAN NICK WATER UNE l' W .t ��xk! O � A�;I _� I.i/.P. 7 Q39 ACRES I- FOUND P.R.Y. NO. LS 3333 GRAPHIC SCALE ( IX MMT ) I t-h - 30 R = NORM L24E OF THE SOUTH nn.SW OF THE NORTH 2O5S96' N895E 10].B4' s�q o } 0.230 ALLWOOD RIVERFRONT (PLAT BOOK 32. PAM 2) MSOY2'12' R-60.00 b2875'41' L-51`10' R-75.Q0' Y L-1248' FLORIDA PRESRVATION ° Cl AREA EASEMENT N6959'3.5'E _ B. M' rO] D.36 ACFUES P I� s 29.07' 9080' k UOIT EASEMENT BOrK 20], PA6E 11N FOND PAM. Na 3859 0.300 \\ 1 IV WALL EASEMENT A+5'301V 6-8'48'32' R-150.00' / R-120.GO' 1r14.42' L-18.45' Ch Br9-S65,2'36'W 6+3051'IT 2'4 R-150.W' S89'S9'39'w _ 186.OT _ R-2SOD' L-29.40' EASEMENT 1 200.00' R-200.00 DO,G• L-f260' \ 1 &52'3SS1' l� R-SO.CV ` 0.36 ACRES 1 1 037 ACRE 1 � Yt 12' EASEMENT EI UTIUT 15' SEMENTE i6D.2E• EASEMENT N)�7s•layV-, \ N6 51 a• � � I�i/ «nv.nru f ISLAND DUNES COUNTRY CLUB (IRPLATTEO) ---------0' ------------------------------ TTE NaR1H 2DSSD ISLAND DUNES COVE _-t3'49'32' R-20000- TRACT 'All R-1)Spp' l•4D76' L-89.I5' C+ F1ry.N]sv CN OAI-88.19' 7A\ (OFFIRECORDAL RECORD BOO( 10]D, PAGE 1919) / / �466 �� I IR-210.00' �2 '^M1 L-13.21' 56615'STE V- V WALL EASE1@NT \ s \ 1 �\ ilk \ g a6O \1i f \ Hp9�'Lrt s wA11 EFSMENi \ PRESERVATION \ \ 7 EASEMENT \ 1 \ `• 15' DRAINAGE EASEMENT �•\ \ 15' DRAINAGE EASEMENT AI&-3S'99 PLAT 800 ISLAND PAGE — RANGE 41 EAST, \ a DOCATLEGEND ES CENTRAL GE OF CURVE \ R NIN RAONS OF CURVE \ L INDIGlES UNGTH OF CURVE \ O NDIG7E FOUND PEIOIANRIT REFMRENCE MONUMENT (PAM.) POINT\ 13EGINNING ■ INDICATES SET PERMANENT REMENCE MONUMENT (PAY.) NO. f19 1286 ® NOIGTE9 PERMANENT CONTROL POINT (P.C.P.) I, NCGTES SET IRON ROD A, CAP NO. LB. 4286 LS LAND 91RVEYOR \ E UTENSm BUSINESS MT UNE OFA \ Q� OF SR -1-A \ N66T REGENCY ISLAND DUNES TWO \ \PREPARED BY: CULPEPPER k TERPENING, INC. 2980 SOUTH 25th STREET d FORT PIERCE, FLORIDA 34981 CERTIFICATION NO. LB 4286 MICHAEL T. OWEN PROFESSIONAL SURVEYOR AND MAPPER \ FLORIDA CERTIFICATE NO. 5556 SHEET 2 OF 2 .... .. .... ....................... ... ,. .. ..... _. ...... .....• ;, .. r. i ' \T I 11; 91 1 L ..i+:' ;•.t.. ;�1 ..rJ �/S' 4'. II,I .1'. .1.• .:yL, •(. i. E• r • ... .. � .. ... �1.).. . ': JI'.i)' .. r:l1.. �•r .u., e� �.. ... ..t .. r ,. ,Y'1f111 1x�w.:i:?. .... 15 ...� .. .. .I F LoT4 [ BOUNDARY SURVEY ,; Sig' /Roy RO VACANT P (LB solg) LEGAL DESCR/PWV. 86a5 _ LOT 5,.LAS TORTUGAS AT HUTCHINSON ISLAND, ACCORDING TO 7H PLAT SET 5/8- IRON ROD j s 7HEREOF AS RECORDED /N PLA T BOOK 44, PAGE 5—A, OF THE PUBLIC 020542 AND CAP (LB 6018) j�RECORDS OF ST. LUC/E COUNTY, FLOR/DA. . 16.78 " S2 9 _ JUIW . 4.47' _ .. >. b I 1' �, 2009. p SURWMRS' CER77RCA nON: PU9LIC WORKS, - sr. �ucle couN n ft / HEREBY. CER77FY..7HA T THIS PLA T OF SURVEY WASPREPARED UNDER MY cS RESPONSIBLE CHARGE AND MEETS THE MIN/MUM TECHNICAL. STANDARDS AS 0.16' , ,oti SET FORTH BY 7NE FLOR/DA BOARD OF PROFESSIONAL. LAND SURVEYORS AND. : _ CORRECT TO THE BEST OF1 MY KNOWLEDGE AND BELIEF. NOT A VALID � TIT IS TRUE OUTND R = . N THE SIGNATURE AND _ THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER., .. W POOL AND Q^ OF Y� PAn0 DECK �o 6N ' \ �op�01 ROBERT BLOOMS ER ✓R. . 8' / � y \�o� 6o PROFESSIONAL LAND SURVEYOR 8 ,� E�oPQ l ....• •'• CONGR�R6 NO. 4134 STA7F OF FLORIDA BENCHMARK. POINT �Op. O i.,' OF CURI/ATURE, . FOUND PK NAIL, AND / D 0/SC (C&T LB 4286) Fes' 2.i79. h LOT 5 O + ELEVAnON = 5.09• .. IRON '?� /,pOA, eR/�. 60 .: . '•,' • . R S CAP S . ; �• .�� �- .::: . (LB ISLAND DUNES COVE. 7ERL 5 O CEN /NE OF 0' RIGHT F WAY �+%,�� �h oo � S89 39',38''W 186.07'P 1. 1� j?'i qos O o v MANHOLE . 185.91 'iM� i J fZ000 ZONE 'VE' BASE' ELEV - 11' • _ . FLOOD ZONE AE' . BASE ELEV.. � g' _ 00' FOUND 5/B' IRON Zd T 5/8" IRON ROD - GRASS MED/AN ROD 518(NO/ R ra AND CAP (LB 6018) S86'21 5 W }. . - B LOT 6 -° 2'CONCRE7E CUR VACANT AND cur>Frz 4. SURVEMRS NOTE.• 1. LANDS SHOWN, HEREON WERE NOT ABS7RAC7ED FOR EASEMENT' AND%OR RIGHTS OF WA Y OF. RECORD EXCEPT AS SHOWN ON THE RECORD PLAT /F ANY. 9 NO AT7FMPT WAS. MADE BY 7HLIS FIRM. TO LOCA7F UNDERGROUND FOO77NGS . OF'BU/LD/NGS OR FENCES ON OR ADJACENT TO THIS Sl7E cERnRcA noN• BLOOMS TER J. BEARINGS SHOWN HEREON REFER TO AN ASSUMED MERIDIAN OF 1, ROY F. W/LLMMS ' 5.8959'38."E. ALONG THE CENTERLINE OF ISLAND' DUNES COVF: . 2. , WACHOWA BANK NA. PROFESSIONAL LAND _ . ORS, INC. - SURVEYORS,: - 4. THIS S17E LIES IN FLOOD ZONE 'VE'. (BASE ELEV. = 11), AE' (BASE ELEV = LB #6018 ' 9),' AS SCALED AND IN7FRPOLA7ED .ON FEMA MAP NO. 12111C-0311=H, COMMUNITY NO...120285, DATED: AUGUST' 19, ..1991. 791 N.E. DI XIE HIGHWAY LEGEND �; cs,,p 5 SITE AREA: 11,761 SQUARE FEET OR a27 ACRES MORE OR LESS. �� JENSEN BEACH, —334FLORIDA 34957 LB —LICENSED BUSINESS PHONE 772334-0868 - , SWEET 1 OF 1 DRAWN Br.. A.C. SCALE: Y-- 20' DALE1 04-01-2005: F.B. - . Al19 19 '' JOB N0. REVISIONS 12-OS CEIMICAMONS A.C. -01-06 STBIWALL TIE IN A.C. 1-21-08 POOL LAYOUT D.C. /23/09 FINAL 1IE-1N JWH 6. LEGAL DESCRIP77ON FURNISHED BY CLIENTxx.xx —SPOT ELEV.9170N3 R — RADIAL �79' 7 ELEVA77ONS SHOWN HEREON ARE REFERENCED TO NA77ONAL GEODE77C D —DELTA PREPARED -FOR.• ROY F. WILLIAMS VER 77CAL DATUM OF 1929. L — LENGTH ISLAND DUNES CODE ou ' FLORIDA. . Sr L UCIE COUNT 8. CITY WA7FR AND SEWER AVAILABLE. ---- -- -- __--- _ ti v �I l 'POD 60. W z 51 R 76;71 86 5 52.9 I LOT 5 i VACANT Jy, N 0 oN �' FLOOD ZONE 'VE' I BASE ELEK — 11' ' FLOOD ZONE 'AC' BASE EL£V = 9'--•� LOT s VACANT SURVEMRS NOTES' 1. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR EASEMENTS AND/OR RIGHTS OF WA Y OF RECORD EXCEPT AS SHOWN ON THE RECORD PLA T IF ANY. 2. NO ATTEMPT WAS MADE BY THIS FIRM TO LOCATE UNDERGROUND FOOTINGS OF BUILDINGS OR FENCES ON OR ADJACENT TO THIS SITE. 3. BEARINGS SHOWN HEREON REFER TO AN ASSUMED MERIDIAN OF S 89'59 38'E ALONG THE CENTERLINE OF ISLAND DUNES COVE. 4. THIS SITE LIES IN FLOOD ZONE 'IAE' (BASE ELEV. = 11), AE' (BASE ELEV = 9), AS SCALED AND INTERPOLATED ON FEMA MAP NO. 12111C-0311-H, COMMUNITY NO. 120285, DATED: AUGUST 19, 1991. 5. SITE AREA: 11,761 SQUARE FEET OR 0.27 ACRES MORE OR LESS 6. LEGAL DESCRIPTION FURNISHED BY CLIENT. 7. ELEVA TIONS SHOWN HEREON ARE REFERENCED TO NA TONAL GEODETIC VERTICAL DATUM OF 1929. 8. CITY WATER AND SEWER AVAILABLE. LOT 4 BOUNDARY SURVEY VACANT ---- -�c> p LEGAL DESCR/P7ADN.- ~-i LOT 5, LAS TORTUGAS AT HUTCHINSON ISLAND, ACCORDING TO THE PLAT SET 5/8' IRON R00 ; i j�; 2008 THEREOF AS RECORDED IN PLA T BOOK 44, PAGE 5-A, OF THE PUBLIC AND CAP (LB 6018) i RECORDS OF ST. LUCIE COUNTY, FLORIDA. j311@LIC WORKS i7i@IE COUN7v FL SU/RWYMS' CERIJRCAA'ON: l HEREBY CERTIFY THAT THIS PLAT OF SURVEY WAS PREPARED UNDER MY pti Ss RESPONSIBLE CHARGE AND MEETS THE MINIMUM TECHNICAL STANDARDS AS s �pti �y®+ SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL LAND SURVEYORS AND MAPPERS IN CHAPTER 61G17-6, FLORIDA STA TUTES AND THA T lT IS TRUE AND �Oa CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. ?+ Rj op ROBERT BLOOMSTER ,al PROFESSIONAL LAND SURVEYOR NO. 4134 STA TE OF FLORIDA co ?9 • B HCURVAMRNT OF FOUND PK NAIL AND / DISC (w LB 4286� N. £LEVARON = 5.09 WON ISLAND DUNES COVE R oop, 0 • � CENTERLINE OF 50' RIGHT OF WA �y- ooyl S89'5'9'38 "W 186.07'(P) • v SANITARY O MANHOLE 185.91 NM) Ise° 1 RIM EL - 7.45' %4 60.00' :. 20 OO ET 5/8' IRON ROD GRASS MEDIAN FUND (NO IRON ~ M./• ./ AND CAP (LB 6018) ROD (NO ID) $86 L ! �/ 5V f: Date't 1e Co. FL ' } t 2' CONCRETE CURB I(ll AND GUTTER proved .y CS771ROA MN: 1. ROY F. WILLM44S 2. WACHO 14A BANK, . N A. LEGEND. - LB - LICENSED BUSINESS xx. xx' - SPOT ELEVA TIONS R - RADIAL D - DELTA L - LENGTH Date P BLOOMSTER PROFESSIONAL, LAND SURVEYORS INC. LB #6018 791 N.E. DIXIE HIGHWAY JENSEN BEACH, FLORIDA 34957 PHONE 772-334-0868 SHEET 1 OF 1 DRAWN BY: A.C. SCALE: 'I* - 2Q' DAZE: 04-01-2005 F.B. A116 19 JOB NO. 8437 REVISIONS 4-12-05 CERTIFICAMNS A.C. 2-01-08 STEMWALL TIE IN A.C. PREPARED FOR: ROY F. KLMMS ISLAND DUNES COVE 14 ST. LUCIE COUNTY, FLORIDA. , f '� /ROiy ALB sn 0 W CIZ A,oa � oaoJ � FLOOD ZONE 'V£' BASE ELEV. - 11' ' 5f 5 9 27.2' f tor 5 At VACANT 1 FLOOD ZONE AE' BASE-ELEV = Lor 6 VACANT SURWMRS NOYES: 1. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR EASEMENTS AND/OR RIGHTS OF WA Y OF RECORD EXCEPT AS SHOWN ON 7HE RECORD PLA T IF ANY. 2. NO ATTEMPT WAS MADE BY THIS FIRM TO LOCATE UNDERGROUND FOOTINGS OF BUILDINGS OR FENCES ON OR ADJACENT TO THIS SITE. J. BEARINGS SHOWN HEREON REFER TO AN ASSUMED MERIDIAN OF S 89 59'38'E ALONG THE CENTERLINE OF ISLAND DUNES COVE. 4. THIS SITE LIES IN FLOOD ZONE 'VE' (BASE ELEV = 11), AE' (BASE ELEV. _ 9), AS SCALED AND INTERPOLATED ON FEMA MAP NO. 12111C-0311-H, COMMUNITY NO. 120285, DA TED: AUGUST 19, 1991. 5. SITE AREA: 11,761 SQUARE FEET OR a27 ACRES MORE OR LESS. 6. LEGAL DESCRIPTION FURNISHED BY CLIENT. 7. ELEVA TIONS SHOWN HEREON ARE REFERENCED TO NA TIONAL GEODETIC VERTICAL DATUM OF 1929. 8. CITY WATER AND SEWER AVAILABLE. /.Or 4 BOUNDARY SURVEY VACANT LEGAL DESCRIPnON.- LOT 5, L A 5 TOR TUGA5 AT HUTCHINSON ISLAND, ACCORDING TO THE PLAT SET 5/8" IRON ROD THEREOF AS RECORDED IN PLA T BOOK 44, PAGE 5-A, OF THE PUBLIC AND CAP (LB 6018) RECORDS OF ST. LUCIE COUNTY, FLORIDA. SURWVRS' C 77RCA770 I HEREBY CERTIFY THAT THIS PLAT OF SURVEY WAS PREPARED UNDER MY RESPONSIBLE CHARGE AND MEETS THE MINIMUM TECHNICAL STANDARDS AS 1�ti shy®+ SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL LAND SURVEYORS AND MAPPERS IN CHAPTER 61G17-6, FLORIDA STATUTES AND THAT IT IS TRUE AND �Oa CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED 100 �j� SPY SURVEYOR AND MAPPER. 10. •6, OF - R o+a� ROBERT BLOOMSTER LAND f ��C, Q lL� 6 , :• "�Rti RB NO. 4134IONAL STATE OF FLORIDAYOR I FA IRON oo, (LB O a g Icy 1 SANITARY MANHOLE RIM EL = 7.45' 4 60.00' FOUND ROD (NO lI R N 20. 00 SB621�15"W £T 5/8" IRON ROD ANO CAP (LB 6018) }: GRASS MED/AN 2' CONCRETE CURB /. AND OU77ER i 1. ROY F. KLMMS 2. .WACHOVIA BANK, N.A. LEGEND. - LB - LICENSED BUSINESS xx. xx' - SPOT ELEVA PONS R - RADIAL D - DELTA L - LENGTH BENCHMARK.• POINT OF CURVA7EIRE, FOUND PK NAIL AND—, DISC (W LB 4286) ELEVATION - 5.09' ISLAND DUNES COVE r CENwRUNE OF 50' RIGHT OF wAY S89'59'38 "W 186.07'(P) 185.99'(M) i RLOOMSTER PROFESSIONAL LAND SURVEYORS, INC. LB #6018 791 N.E. DIXIE HIGHWAY JENSEN BEACH. FLORIDA 34957 PHONE 772-334-0868 SHEET 1 OF 1 DRAWN BY: At SCALE: -I' - 20' DATE; 04-01-2005 F.B. A116 19 JOB NO. 8437 REVISIONS 4-12-05 CERnFlCAnoNS A.C. 2-01-06 STEMWALL TIE IN A.C. PREPARED FOR: ROY F. KL/AMS ISLAND DUNES COVE ST. LUCIE COUNTY, FLORIDA. 0� 061 — (!)2.lq I LQ ` �` i♦� i #4 LOT 4 VACANT SET 5/8- IRON ROD AND CAP (LB 6018) L3, , / 0+ BOUNDARY SURVEY LEGAL DESCRIP770ft LOT 5, LAS TOR TUGAS AT HUTCHINSON ISLAND, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 44, PAGE S-A, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. SURVEYORS' CER77RCA770N-• I HEREBY CERTIFY THAT THIS PLAT OF SURVEY WAS PREPARED UNDER MY RESPONSIBLE CHARGE AND .MEETS THE MINIMUM TECHNICAL STANDARDS AS SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL LAND SURVEYORS AND MAPPERS IN CHAPTER 61G17-6, FLORIDA STATUTES AND THAT IT IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. NOT VALID WITHOUT THE SIGNA TURE AND THE ORIGINAL RAISED SEAL OF AFLORIDA 'LICENSED Y SURVEYOR AND MAPPER. R BERT BLOOMSTER ✓R. PROFESSIONAL LAND SURVEYOR i0 NO. 4134 STA7E OF FLORIDA ROD �8 �RoN ; p O �R B 6, IRON R S CAP R/ l /oJ o s�98 . (�. A • ((� O v T 'O;r� O r+OO �1 '1—�•pA4`SAWARY FLOOD ZONE 'V£' O� MANHOLE.� _ BASE ELEV = 11' nj 1 RIM EL - 7.45' I FLOOD ZONE i4E' 60.00' ' BASE ELEK = 9'----, IRON ROD CRASS MEDIAN FOUND 5/8- IRON 2a OO ET 5/8- ROD (NO /D) AND CAP (LB 6018) S86'21 '15 "W LOT 6 VACANT 2' CURB AND GUTTER SURVEYORS NOTES: . 1. LANDS SHOWN HEREON WERE NOT .ABSTRACTED FOR EASEMENTS AND/OR RIGHTS OF WA Y OF RECORD EXCEPT AS SHOWN ON THE RECORD PLAT IF ANY. 2. NO A TTEMPT WAS MADE BY THIS FIRM TO LOCH 7F- UNDERGROUND FOOTINGS OF BUILDINGS OR FENCES ON OR ADJACENT TO THIS SITE. CER77RCA77oN' J. BEARINGS SHOWN HEREON REFER TO AN ASSUMED MERIDIAN OF 1. ROY F. WILLIAMS S.8959'381E. ALONG THE CENTERLINE OF ISLAND DUNES CODE. 2. WACHOWA BANK, N.A. 4. THIS SITE LIES IN FLOOD ZONE 'VE' (BASE ELEV. = 11) 'AE' (BASE ELEV = 9'), AS SCALED AND INTERPOLATED ON FEMA MAP NO. 12111C-0311-H, COMMUNITY NO. 120285, DATED: AUGUST 19, 1991. LEGEND.• 5. '�SM�ITE AREA: 11,761 SQUARE FEET OR 0.27 ACRES MORE OR LESS LB'- LICENSED BUSINESS '' 6�4Y, GAL DESCRIP77ON FURNISHED BY CLIENT. xx.xx' -SPOT ELEVA770NS R - RADIAL 7., ELEVATIONS SHOWN HEREON ARE REFERENCED TO NA 17ONAL GEODE77C L -DEL TA W-R77CAL DATUM OF 1929. - LENGTH f: CITY WATER AND SEWER AVAILABLE. D to Co. F nit ro BENCHMARK.• POINT OF CURVATURE, FOUND PK NAIL AND—, DISC (c&r LB 4286) ELEVA77ON = 5.09' ISLAND DUNES CO l/E CENTERLINE OF 50' RIGHT OF WAY S89 59'38 "W 186.07'(P) 185. 91 '(M) BLOOMSTER PROFESSIONAL LAND SURVEYORS, INC. LB #6018 791 N.E. DIXIE HIGHWAY JENSEN BEACH, FLORIDA 34957 PHONE 772-334-0868. SHEET 1 OF t DRAWN BY.' A.C. SCALE' i- - 20' DATE. 04-01-2005 F.B.. A116/19 JOB NO. .843 REVISIONS 12-05 CERTIFICATIONS A.C. z-01-03 STWWALL nE IN A. 1-21-011 POOL LAYOUT D.C. /23/OY FINAL TIE-IN JVM /16/ost MISC. 17MS DPK PREPARED FOR.- ROY F. KLIAMS ISLAND DUNES COVE ST. LUCIE COUNTY, FLORIDA. IRON RO AP (LB 6018) u N ,; %i I. o� o 0.10 Z k x p. is LOr 5 a� VACANT V� y 01 s • � 9 2 � �¢ �rO�� j k•� FLOOD ZONE le, BASE ELEV - 11' ,G _ FLOOD ZONE 's1E' BASE EZEI< = 9' Lor 8 VACANr SURWYMS NO&M 1.. LANDS.. SHOWN -HEREON WERE NOT ABSTRACTED FOR ,EASEMENTS AND/OR RIGHTS OF WA Y OF RECORD EXCEPT AS SHOWN ON THE RECORD PLA T IF ANY. 2. NO ATTEMPT WAS MADE BY THIS FIRM TO LOCATE UNDERGROUND FOOTINGS OF BUILDINGS OR FENCES ON OR ADJACENT TO THIS SITE: 3. BEARINGS SHOWN HEREON REFER TO AN ASSUMED MERIDIAN OF S.8959.38"E. ALONG THE CENTERLINE OF /SLAND DUNES COVE. 4. THIS SITE LIES IN FLOOD ZONE 'VE' (BASE ELEV. = 119, �4E' (BASE ELEV = 99, AS SCALED AND /N7FRPOLA MD ON FEINA MAP NO. 12111 C-0311-H, COMMUNITY NO. 120285, DATED.- AUGUST 19, 1991. 5. SITE AREA: 11,761 SQUARE FEET OR a27 ACRES MORE OR LESS. 6. LEGAL DESCRIP7701V FURNISHED BY CLIENT. 'Z ELEVA77ONS SHOWN HEREON ARE REFERENCED TO NATIONAL GEODE77C - VER77CAL DATUM OF 1929. ,8. CITY WATER AND SEWER AVAILABLE. LOT 4 VACANT SET 5/8" IRON ROD AND CAP (LB 6018) '6 4! 4.3 A2x 5.78' x?, o � 9 X3z, h•� +� + g 89r 6 �o, AA FOUND S/8" IRONS 20.00' ROD (NO ID) C86205V CEMMA now.• 1. ROY F. WILL/AMS 2. WACHOWA BANK, N.A. LEGEND. LB - LICENSED BUSINESS xx.xx' - SPOT ELEVATIONS R - RADIAL D - DEL TA L - LENGTH 6ET 5/8' IRON ROD AND CAP (LB 6018) \X BOUNDARY SURVEY LEGAL DESCR/P)MM: LOT 5, LA TORTUGAS AT HUTCHINSON ISLAND, ACCORDING TO THE PLAT THEREOF -AS RECORDED /N PLA T BOOK 44, PAGE 5-A, OF THE PUBLIC RECORDS OF Sr LUCIE COUNTY, FLORIDA. SURWWRr CERnRCA now: I HEREBY CERTIFY THAT THIS PLAT OF SURVEY WAS PREPARED UNDER MY RESPONSIBLE CHARGE AND MEETS THE MINIMUM TECHNICAL STANDARDS As' SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL LAND SURVEYORS AND MAPPERS /N CHAPTER 61017--6, FLOR/DA STATUTES AND THAT /T IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED . Y SURVEYOR AND MAPPER. ROBERT BLOOMSTER W. PROFESSIONAL LAND SURVEYOR i9 NO. 4134 STATE OF FLORIDA BENCHMARK.• POINT OF CURVATURE, FOUND PK NAIL AND 61y DISC (C&T LB 4286) ELEVAAON a 509' 5 IRON R (18 CAP ISLAND DUNES CO CENTERLINE OF 50' .%HT OF WAY �OvI 8 `' 589 59'38"W 186. 07'(P) M NHo £ 185.91 '(M) rq k RIM EL = 7.45' GRASS MEDIAN MIN. SETBACK REQ. FRQNT a�;> 2' CONCREIE CURB "' SIDES AND OUTTER CNR SID rj REAR BLOOMSTER PROFESSIONAL LAND SURVEYORS INC. LB #6018 791 N.E. DIXIE HIGHWAY JENSEN BEACH, FLORIDA 34957 PHONE 772-334-0868 SHEET 1 OF t ORA" BY: A.C. SCALE: f m 20' DAZE, 04-01-2005 F B. A116 19 JOB NO.8437 REVISIONS . 12-08 CERTIFICATIONS A.C. PREPARED FOR: ROY F. WJLL/AMS ISLAND DUNES COVE a ST, LUCIE COUNTY, FLORIDA. 0 A2x 5.78' x?, o � 9 X3z, h•� +� + g 89r 6 �o, AA FOUND S/8" IRONS 20.00' ROD (NO ID) C86205V CEMMA now.• 1. ROY F. WILL/AMS 2. WACHOWA BANK, N.A. LEGEND. LB - LICENSED BUSINESS xx.xx' - SPOT ELEVATIONS R - RADIAL D - DEL TA L - LENGTH 6ET 5/8' IRON ROD AND CAP (LB 6018) \X BOUNDARY SURVEY LEGAL DESCR/P)MM: LOT 5, LA TORTUGAS AT HUTCHINSON ISLAND, ACCORDING TO THE PLAT THEREOF -AS RECORDED /N PLA T BOOK 44, PAGE 5-A, OF THE PUBLIC RECORDS OF Sr LUCIE COUNTY, FLORIDA. SURWWRr CERnRCA now: I HEREBY CERTIFY THAT THIS PLAT OF SURVEY WAS PREPARED UNDER MY RESPONSIBLE CHARGE AND MEETS THE MINIMUM TECHNICAL STANDARDS As' SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL LAND SURVEYORS AND MAPPERS /N CHAPTER 61017--6, FLOR/DA STATUTES AND THAT /T IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED . Y SURVEYOR AND MAPPER. ROBERT BLOOMSTER W. PROFESSIONAL LAND SURVEYOR i9 NO. 4134 STATE OF FLORIDA BENCHMARK.• POINT OF CURVATURE, FOUND PK NAIL AND 61y DISC (C&T LB 4286) ELEVAAON a 509' 5 IRON R (18 CAP ISLAND DUNES CO CENTERLINE OF 50' .%HT OF WAY �OvI 8 `' 589 59'38"W 186. 07'(P) M NHo £ 185.91 '(M) rq k RIM EL = 7.45' GRASS MEDIAN MIN. SETBACK REQ. FRQNT a�;> 2' CONCREIE CURB "' SIDES AND OUTTER CNR SID rj REAR BLOOMSTER PROFESSIONAL LAND SURVEYORS INC. LB #6018 791 N.E. DIXIE HIGHWAY JENSEN BEACH, FLORIDA 34957 PHONE 772-334-0868 SHEET 1 OF t ORA" BY: A.C. SCALE: f m 20' DAZE, 04-01-2005 F B. A116 19 JOB NO.8437 REVISIONS . 12-08 CERTIFICATIONS A.C. PREPARED FOR: ROY F. WJLL/AMS ISLAND DUNES COVE a ST, LUCIE COUNTY, FLORIDA. 0