Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
OFFICE U E O Y: Date � 1. Fee Due: Receipt# J� Permit # n-)7 bq-ro;j- ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and Zoning 2300 Virginia Avenue 'SCANNED Ft. Pierce, FL 34982-5652 BY 772-462-1553 St��° Lucie CQUn fY APPLICATION FOR ALUMINUM STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 191 Zb 6me pv-rr Pl 2. S/D NAME:rrivf--'Nw-,— SITE PLAN NAME: 3. PROPERTY TAX ID #: �'2� � .'0 b 0 D 2-9 4 0 0 "Z 4. LEGAL DESCRIPTION (attach extra sheets if necessary): V O V 33 W7 l4-(VV Ge M 1 Lk- L� f i (c a- i Q7 ?7 o, qw 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK fS30 NO. D NO. NO. 11 9. PARCEL SIZE: ACRES/SQ FT. �� 10�®LOT DIMENSIONS O 35 X VO 10. SETBACKS (ACTUAL) FRONT:" BACK: TO (RIGHT SIDE:_ LEFT SIDE: 33 r 11. TYPE OF STRUCTURE (2%WLL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION =New A= Addition R = Rebuild SG Slab on Grade = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION SCREEN ROOM ❑ NEW ❑ EXISTING X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X POOL ENCLOSURE ❑ NEW ❑ EXISTING X 'rj -� ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X TOTAL SQUARE FOOTAGE OF CONSTRUCTION 12. VALUE OF CONSTRUCTION: $ 'y The value of construction is used to determine le amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 2119107 d OWN`9R INFORMATION NAME: 0 ALMIJ P b - ADDRESS: oDIV L - CITY: L- ,, !! STATE: L ZIP IM�D PHONE (DAYTE): �04'2�3� email: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): (_) CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: ST. LUCIE COUNTY CERT #: 1 BUSINESS NAME: :5�f'� PNO"Vi -r gc , 0 R h -- VIA L- M C. Asr AL_ fl en w tl m QUALIFIER'S NAME: ADDRESS: % 71 f 61 %i wee= CITY: `J�cl P { �iQ_ STATE: �L ZIP PHONE (DAYTIlVIE): ( ) FAX NO. email: ARCHITECT/ENGINEER: Pow V " � ADDRESS: CITY: STATE: ZIP PHONE (DAYTEVIE): ( ) NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) O ICE S O iI � 4 �NL- fl ii 5 ZONING SECTION TOWNSHIP / l.D RANGE MAP NO. 3-3/3 7 �� ZONING i A� LAND USE LOT CVG % Additional Permits �Yes o REPORT CODE "] BIMS FEE MISC FEES TOTAL FEES r 5�, REVIEWS ZONING ZONING PLANS MISC. VEGETATION VALUE OF CONSTRUCTION REVIEWED BY EXAMINER USING ICC TABLE DATE COMPLETE INITIALS G� V LIB PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: ❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`s wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (11) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100:02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4'or Category, 5'structure, as defined in the current Edition of 3.1.2.4_and 3.1-.2.5, proper energy calculations an&long form equipment -sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building -Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4`s wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: ` This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT- WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS .NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceed the footprint of the structure that was in existence prior to removal by the storms. *'AY4 Yi O CONTRACTOR SIGNATURE CONTRACTOR SIGNATURE STATE OF FLO 11 STATE OF FL COUNTY OF COUNTY OF The foregoing ins� �ent w s Zaccw edged he foregoing went eaknowl54ed before e is�aday of 2, by fo e me t ' y 2 by who is personally , personally own to me or who ha/sI ro uced own to me o who has rod ced - All identification. �� '� "�3 � identification. Signa re of No �c.. •Qli�Qle.� JRIE A GERSTEMEIER (SEAL) "OMMISSION # DD 514317 (SE .i(PIRES: February14, 2010 . 1� LORIEA GERSIEMEIER .ded Thfu War Public unaerwr ters � _ -N ,� MY COMMISSION # DD 514317 •. EXPIRES: February 14, 2010 IMPORTANT NOTICES: tionaddtfitiiNr�iayPutiadune@twdtcre • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING. FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. * S�{ •iG1! /l ^l Code Compliance Division 2300 Virginia Avenue Ft Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://Stiucieco.gov/ce INSPECTION CARD rermit #: SLC- 0709-0283 Conf #: 610 Type: Pool Enclosure .Issued 10/02/2007 Status: FIN Double Fee: No Job Location 8920 ONE PUTT PL City: PORT ST LUCIE Jurisdiction: St. Lucie County Lot: 11 Block: Parcel: 3334-500-0028-000/2 Subdiv: POD 33 At The Reserve Phase 1 Kingsmill Flood: X Elev: Flood Map: 275F Job Description: NEW CONSTRUCTION OF A POOL ENCLOSURE (POOL PERMIT #23051129) . Setbacks Left: 33.00 Right 15.50 Front Rear: 8.75 Inspection Notes: INSPECTOR PLEASE VERIFY 2 x 8 ROOF BEAMS & 2 x 5 WALL COLUMNS AS SHOWN ON PLANS **CODE CASE** KC Contractor SMITH JAMES A JAMES ANDREW SMITH INC (561) 743-8145 1311 S COMMERCE LN # 7 JUPITER, FL 33458 Property Owner BARBARA MARONPOT (772) 464-7730 8920 ONE PUTT PL PORT ST LUCIE, FL 34986 SUB -PERMITS Permit # Status PT Cert # DBA Owner / Builder Job Description INSPECTIONS - For Requests, Call: (772) 462-1261 Permit # Code Description Priori Date Sched. Res Description Inspector Date Insp. 0709-0282 900 Plan Revision 0 92 Accepted As Noted Kathy Cicio 11/21/2007 REVISION TO PROVIDE ENGINEERED RETRO-FIT FOR ROOF BEAMS & LARGER COPY OF PLANS ENGINEER DO RETRO-FIT PER: KENNY ARNOLD & KATHY - OKAY TO HAVE SEPARATE 0709-02821 101 Notice of Commencement 1 92 Accepted As Noted Barbara Counsello 10/10/2007 0709-028: 999 Final Inspection 2 11/29/2007 99 Final Approval Shaun Milligan 11/29/2007 per engineer drawing that was revised 11-21-07 11/28/07 incall schedule with jim/ contr. bac Re -inspection 1 0709-0282 999 Final Inspection 2 10/11/2007 81 Disapproved roof beams are 2x7 plans call for 2x8 stopped inspection need plans we can see print is too small Shaun Milligan 10/11/2007 Scheduled: Wed Oct 10 14:21:52 EDT 2007 with value: null Scheduled: Wed Oct 10 14:22:32 EDT 2007 with value: null Scheduled: Wed Oct 10 16:27:17 EDT 2007 with value: Thu Oct 11 00:00:00 EDT 2007 Permit Nun 0709-0283 10/10/2007 _14:19 1561-743-9?55 PALM COAST OALUM I--- Qk' THE CIRCUIT COT �- SAINT LUCIE TY FILE.(1 3118E2q oI? 8.ti 2890 PAGE 2319, Racordad 10/10/2007 -)11.31 AM PAGE 01 � nc 0-70f ~ Ga 6R OF The whdemlgned hereby given notice then imprmtnm,t will ba We to curtain reel Property, and in ace( Florida Smtucs the following ihfaimatlon is provided in the Natieo of Commeneema+t I. Dl�L�llptrpN O➢pRoaRBhry (Legal deacripuon and street address, lt�vailable) TAR Folio NlnysRlt: suanrvcs�oN� C� (�• 1! � \\� , ��,�lo�x •rx.tcT t.or 1 �,,,,_e 2. GENXRA.L DBScleWnON EW AMpROV&Nxr T: 11 3. OWNER INVURNATION: a Name r b,-, Y d N-M end addrga of Ice 4. CONTRnCYou-sm S, SURETY'S NAME, ADDRXSS AND pHONE MU—XR AND BOND Aldobrrre A RECEIVED O C T 1 0 2007 BY, will, Chapher 713 u —v 91L W �► I ,� c w w l;l, G 6. LR"SR'S AAM ADDRESS AND FROta lvl1 MR; b 7. k6rsom within the State of ftlorida designood by Owner upon whom notices or ocher documents may je served as pW, i t Section 713.13 (1) (a) 7„ Florida Statutes: RAM APPRESSAND PHONE NlIMB$xnr U- UJ W p N/A 0 E,• In addition to himself or herself, Owner designator, the following to mceive a copy of the Iaenor's Nos as providuMh Sec 7t3.13 (1) (b), rlcr 4 statutes: I— I-- X NAMA. ADDRESSAND pilONg NIIMBRRS cow N/A 9. Expiration date of notice of commencement (the expiration dabs is I year :From the data of recording un ess a different dace is specified);_ -_-, 20_ a 6► - Sign lure of Owner or Print Name and l?rovide Sigoat `s'l 11r)QUIce Owner's Authari and plficer/Directo erlManeger State of Florida County of Palm coach The foregoing insmun+e'ntt was l acknowledged bdforo me this day of '�Q� 20 B)c /- A 4 /'S . I `4 y�i Oml es ��iLQlI (name ofpsrson) (typo of 4utboilly„„o,g officer, trustee, attom in tact) for ryry (name of party on behalf of whom instrument was executed) %� _ L._..., Under Penalties of penury. I declare that I have read tho foregoing and tbot the facts In it are true to the be$t of rsy knowledge and belief (Section 92.525, Florida Statutes). - 4 Rev.ee-14-01 (sAxwdieg) Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1653 Fax: (772) 462-1148 http://stiucieco.gov/ce BUILDING PERMIT Issued: 10/02/2007 Conf #: 610 Permit #: SLC- 0709-0283 Job Location: 8920 ONE PUTT PL ,City: PORT ST LUCIE Permit Type: Pool Enclosure Job Description: NEW CONSTRUCTION OF A POOL ENCLOSURE (POOL PERMIT #23051129) Subdiv: POD 33 At The Reserve Phase 1 Kingsmill Lot: 17 Block: Parcel: 3334-500-0028-000/2 Page 1 Contractor SMITH JAMES A JAMES ANDREW SMITH INC (561) 743-8145 1311 S COMMERCE LN # 7 JUPITER, FL 33458 Property Owner BARBARA MARONPOT (772) 46.4-7730 8920 ONE PUTT PL PORT ST LUCIE, FL 34986 Setbacks Left: 33.00 Right: 15.50 Front: Rear: 8.75 Zoning: PUD Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: 275F Flood Zone: X Elev: Job Value: $ 35,507.42 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange to . )4 Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit. is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. 0. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucleco.gov/ce Date: 02 October 2007 Job Address: 8920 ONE PUTT PL Received By: spellsv Paid With: CK Paid By: PALM COAST ALUMINUM Building Receipt Sign: Receipt#: 0000057819 ermit Number: SLC- 0709-0283 Amount: $155.00 'redit Card Number: Check Number: 12449 Code Compliance Division 2300 Virginia Avenue Alert Maintenance Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://Stlucleco.gov/ce P"PERV INF.614 JON Parcel # 3334-500-0028-000/2 Jurisdiction St. Lucie County Permit # 10709-0283 Lists first permit on property. Reference only. Zoning Planned Unit Development Address 8920 ONE PUTT PL PORT ST LUCIE 34986 Add Alc;rt — 4 Active I Contractor Licensinc 07/13/07 1 PLACED THE PERMI- 07/13/2006 iiegoa 07/13/07 1 PLACED THE 05/12/2006 diegoa 07/03/2006 williamsf PERMIT BACK TO BE FILED - 07/13/2006 diegoa SINCE ITS TAKING LONGER FOR THIS CASE TO BE RESOLVED-MB 05/29/07 1 HAVE THIS PERMIT ON MY DESK - SINCE ITS OLD I DID NOT WANT TO FILE IT BACK YET - EXT 1542 MB 7413.06 D'O'l16 E FEE. NO---- PERMITaFOR POOL- 'ENGLOSU.RE..DAA--- Code Compliance Division 2300 Virginia Avenue Alert Maintenance Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiu cieco.gov/ce PROPERTY• - Parcel # 3334-500-0028-000/2 Jurisdiction St. Lucie County Permit # 23020414 Lists first permit on property. Reference only. Zoning Planned Unit Development Address 8920 ONE PUTT PL PORT ST LUCIE 34986 Add Alert r: 4 Closed Permitting 5.12.06 PO#23051129 AND PE#: 05/12/2006 diegoa 07/03/2006 williamsf 5.12.06 PO#23051129 AND 05/12/2006 diegoa 07/03/2006 williamsf PE#23051132 EXPIRED. DAA 07/13/2006 diegoa 5.26.06 RECVD FAX FROM HARBOR POOLS SHOWING PO#23051129 HAS BEEN FINALED. DAA Code Compliance Division 2300 Virginia Avenue Ft. Pierce, Fl- 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 24 September 2007 Job Address: 8920 ONE PUTT PL Received By: humphreya Paid With: CK Paid By: PALM COAST ALUMINUM Building Receipt Receipt #: 0000057618 ermit Number: SLC- 0709-0283 Amount: $50.00 �redit Card Number: Check Number: 12513 Sign: OFFICE USE ONLY: �Cl�'Wlta , DATE FILED: •Zed ' PERMIT NUMBER:oloot - C-)Z-,' REVISION FEE: RECEIPT NO.: COUNTY DEPARTMENT OF •DEVELOPMEINIT :E r • •IERCE, FL • 821-5651. .462-1553 F • •' s ONS PROJECT INFORtiIATION 1. LOCATION!SITE ADDRESS: T1zo 6�?)Vlc S e-,— II 2. DET AILED DESCRIPTIONS OF PROJECT REVISIONS: fy rO_gc�F- 6�S72,06- Z-X? Pub 00 06 W 17'/f 3. 4. , " V CONTPLACTOR INFOR.IIATION S ST. OF FL REG./CERT# . ST. LUCIE COUNT' CERT.= BL:SINESS NAME: Qualifiers Name: ADDRESS: CITY: PHONE (DAYTINIE): .ARCHIT/ENGINEER: NAME: - v D%Lls ADDRESS: 23 a - S CITY: STATE: PHONE'(DAYTItiiE): �I S�--i�7 — Z b vl FAX#9<-4C--'7�� c 9. Wsd 14, qlpAV_'v 0A "ZIll, �6n__ THESE,'.PLANS CONFORM RMTO THE f,B t W/ 250,06:AA, EN`Qm,ENT-S- DESIGN ,--,07AS E R21 40T.WR WINDS; EXPOSURE " TARNW$XMGtNEERWG,AW. Civil 0 Structural 0 Architectural 7360, •NX 5th Street -PI Mat. ion , FL. 33317 Phone (954) 727- — 20,27 Fax (954) 727 — 9644 bETIAIL FOR:. mARONPOT RES. Z0_20 ONE 'PUTT PL. 06Rt -ST. LUCIE, FL. CONTRACTOR PALM COAST ALUM. "W.T.P. qss ,Bu - in "CA . 4". dOB-- f -MARONPOT DATE: 10/23/07 SCALE: N.T.S. DRAWN' BY: W.T.F. CHECKED BY: q— 'SHEET -NO. 1 OF 1 2w I Ll I Building ti Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucieco.gov/ce Date: 20 November 2007 Job Address: 8920 ONE PUTT PL Received By: goycochb Paid With: CK Paid By: PALM COAST c Sign: Receipt #: 0000058983 'ermit Number: SLC- 0709-0283 Amount: $50.00 �redit Card Number: Check Number: 12566 v +i t•1FtY-63�.2004 22:47 from: HARBOR BAY POOLS 7?2 8.78.13859 To:561 743 93 � :.-_i F.8�9 , A CATV • n.rA Awke WW w ua NA O.C, •NOT RADIAL ■ OVMWN0 CA1wNT. VAN. VAN. WCARYAWT-WWAY . �ANCI'ARY ®. SET 5/4• IRON RDo ■.CA'IR10+19tN 0I Te kw a 11VCSq QUO_ aR9 0/I • DV lICIA4ISOMO��' [AO$Kw • aP10rAL IIQCORD (OOR 9OFF09T O.D.T. af. ■ SOUL we[61.781EPNo8B . eon Igo WITH CAP WITNESG CORM LO +COra • 1 IF WPDET CDiiCRf:TC C9 • GM BRAM "441' i 0 ' s TOP � • TYPICAL ■ CllCTAlC 9LRV.C4 COC4�• D - aV, . • d ID OL' CAtICM�NT PA. PLC, PO►, ■ PLAT BOOK . POWT OF QNVAriRG ■PeAtAA U VA u1.P UTI1,I1 r L►A PRP.UAVATiON. CATV • LJII�IT POOT PLOP. ■ eu VATION + ED4nx OF PAOF PD.E . R0•e rcONTRZPOINT • PRIVATE Dr copmC CAI . PRIVATTI OAa; LtAEE'A1nT W 0 ! ■ S1'� 0✓0' ION ROD WiPH OAP No, 68 a6T4 • FUM e/a3 . MR ROD WIN CAP No. LD 074 YER FLUPW p%ooR Plc' P.OD. • PARKER KALON NAZI; . POINT Of 0E01NNWe a • POUND MWAlr W GO MM POINT' ■ SET P•K NA16 WM DISK PA LO 4e74 PB,Lt,' PA,w 1*10 ■ P6C'00 I LAIN [6ASt!IAIRIT RO•C. r POINT 0P �ENGligm Q ■ F0M f•IS NAIL.. NQi LO OOT4 • WATER 90MMI keMG • RLCRlpA PCWgI M LlG1iT ■ I.ANI! WiiN►gNANC1: SABCMEN` PN.Ib PROP • MMAIe peCr4k,4C MON M W . PROPMD : P WATER VALVC ! OANITAAT 99RVIOC Nat ■ LAFDiCAPC AND BICNAOC EAOEAtpVT ■ µAIINt>Lg / T ... ■ POA1t OF TANOlNG / a ■ POUND /CRMANFNT' RCFenqu MQNVtmw Oe i , , A.U,L • A ■ PRIVATL UT16M'Y LM.WNT ■ AAp1Uf ■ LNIOTOVO C6CVATlCN IN F04T t' N�AI o9CIP910. VERTICAL DATLM qAD. .RADIAL 0.00 s ■ PROM= EL&VAT10N0 IN PUT ' �-- •t>R+A�IA/CAow>lgIG1Y0R 1` �` ` ' �. •.�,'•' �` a7• 5 UNPL.ATTED 1 e,r II.T; 135.001 ' � N $wr '4Z"W I RAD. :.i, n� ! a> I R•420.00' .'LOT 18 MEASURED TO END of BOARD BEING AL OF Off' i7, ACCORDING TO TH9 PLAT OF POD 33 AT TH9 . RMFIVE, PHASE I - KINGSMILL. AS RECORDED IN PLAT 9OGk'6, PAGES 13, 13A rWRU IX PUBLIC RECORDS; OR ST. LUCIE COUNTY, Nat 9 NOT l IB P NAM Poll ACOtR FLORIDA. tIo !e NOT Aw11INA9LG ' • . � MCMEB, LTD, � IYiLANDS ",W-NOWIIN[REOR.OcRRDSYE NOT AlbarPPPICII CTL,pp04 IC �D U\at4\Q00.001t\t0lp\Lt+D\LOYiVYE\fJI�II)trep 69/el/DaoQ Othtb�t AM QA� 17ri17!•Dl► wAr (If „cooRD IY TMII OPPIce III!$! ENMAC1eAENTe, ARE AO S►IptyN :IGIIPTION Fw1 BY C41ltNr I At II BUURVOY 1ilAM!' I.uY DEC P0" IN-741 PIUCDL DC IWt CCMOR 5 0 T�W9 QC M ON /� /'y BOUNDARY j I� p;'SURVEY �` �` i10 E1ItTCN 13 TFIf. PAOPLItTY r L kwtor4 NOOSE r wEB6, lN4 AND EMAIL NOY MAP V L� V U N' 1 A f1 Y S U R V E Y RDP1100uCku IN WNCLC OB PRAT WITIOUT Tpg PERM16910N OP LAw f '.Ee. ING III WN1'Ihq ECN, Ry006C M ARM ONOWN FA`RbON AR@ dAr;, PN TK NORTMLr LINO OF I.OT 7 WbAAT DqIQq IIU�NQ1out l w!, ARE- AND R 6L,- rA p I►� D MtA'JURL1Ti I Tcp,q,26S CL1�NTj RESERVE' H 0 MI E S LTD. - 'HFJtWt62 NDTED, � i � .' R VATIgNE �vA9V ►ijMay ARC OAaaD:ON R11F V D. AC WT►ACNT 0P 11Ee T4 AP 0,M lidfN3. LIE lalRMA' iDVq ,1(' A(..*ORDINO TO.7'M!: /LDOD INDVRANCg , „ 'R MAPP'1 NT. 18921lE.0Prr ATO AUOUET 10, 1IPI LB 0 66T4 1 1 'AD 1A IF MY AKE A9 HWWn R Or rta,D eLR /gy, BplT[MpeA e,.loD2 (� a P • • • . O • ' �. • • •;4 t 4w.� r �cC l `l = Di MIN. SETBACK REQ. FRONT SIDES_ s CNR SIDES_ REAR ZNG.0 TECH. q/ . - -woa� THESE P1ANS AND ALL PROPOSED ARE. SUBJECT TO ANY CORRECTIOTHAT REQUIRED BESSARY N ORDER10 qES. MAY BE NEC COMPLY WITH ALL APPLICABLE C 6 . t � � xr \Q T R L BUILDING DIVISION ►NSPECTi® ALUMINUM PRODUCTS INCLUDESN FOR VISIBLE CONNECTIONS ONLY ALL HIDDEN CONNE AND DETAILS. DETAILS ARE THE RESPONS AND OF T�iE.ALUM►NULITY M CONTRACTOR. 37; tU 8U/1"o V13 Q ��+N QarE 7P411 r®eAy$pp s�k�pr otreoR! IY/L� ��E bg/ 13/2dFJ3 iM: 49 r AR aff"ZON VAL rnn+ rHd f'fOAC' ipitter (561) 743-8145 1,oynton (561) 737-1882 �' 43-9355 r,Aun Vu+a�l H� uln Palm Coast Aluminum custom Screen Enclosures 1311 Commerce Lane, Suite 7, Jupiter, Florid T1 l Since t 9W I Stuart (772) 337-3138 Fax, (561) 743-9355 rI&#& 1 '� ► operry Owner_ -..�. K c �,: ()Hm. P'h..r.�...— restallatlonAddro>as <8ei C� t�_ .I +.�� Clty Nk.Ph.� s _Cell Ph.— mac_ D41. Dat® ;rsr a Color Bronx hlte Q Concrete (Slab/1^'csott®r) Tsar Out CJ HOA Approval Pleq, (Cut & Cap Sprit1kler I.. nee) icreen Color: Charcoal ;Crean Me's Mansard - 112 MansardQD yak Gab1©• other -�to �aat Hei c ice' x - 1 4 Chair Pill Hel !j t) Dc�tSrs Handie Heel t: High • Low ` Gutwrs I permit included: Yes • N a,. _ ..... ,. _ . I°cn Patio • Pbmh i ,.,....._ lama [I wry JO QT( C) INS *h � rD•01 ' .� t ' ItKo w.tsu K401`1 ry ky to aandnd pWn<u Mry WWWj•^ r d f I GMra NKn 1„�►Ivint •AII� [mi WIU D.dwM .. . . . t ems Chwe OW IM 4W O OW 6641, SAS wMMW^u , I WMn�p 1�.4M mi/1, K=IdYI� O'' d4wi jWWFj — W menotm a wi hip 30 l { mnwt. tFM WvrowF wbl•a' l 40 and k VOW thmals ' &A"dog- of the --jar. ' ,• ,i ,. .. .. .. M wau n i. nerw.rY a eNry hpJ • ^ °D & FASTENERS • 1L• L.X RUSIONS MINIMUM 4 0TH"NOS «+tom. dw twm. uxl t—'.& of U0 ties W II � .# /Ul jo65 ING!•UD R 1111 Q ARMTER ON MATERIAL. AND WORKMANSHIP wy u�wwt err I wuw•.Irr �. m I UNCO�ICIITft'itN - r elf sar+d+ km« And►•r• i�nith. Ine s WRe I17 DaPO81' s I Vefm ea. i ixn +.uw� ee •r�►+e � he U;1 prowl l to do asfiml. w �e ALI„ 140MEOW1�£ r RTION OF INSTALL uwl . ,m.aru+�.�cw+w►'. Ile mit of +m CWin of lien VI�°•d bl fWrn cow AWM� 1MU e• Im.M+d•dpa+K A slt shot tx Gt lut itte 194 dent:ri 'wt ue ultti V'W m n�lr.a SKtion $01,02s, Plarldlt �ma (Cnhil�rwsr ►rotMlYwa, t bee that "...the bqw hu :� rl�It to avn d a IIo1M �' Cot den eek! Wn)I mldn4m of du thkd buskmz dr/ ~ the day on Whkh tfN OuyM' 1♦iy1Y m _^n�u UWe hog read ti►a for Ina f�+aPONO carttr►ca and aceol+c the lone on the tdlmt end c�+ed'i-p-o�, _ 1/3 2�j D' t° 4 1/3 Purchaser:___. ll 1/3 on all U Collor, -�- •--�--- a: �:�, ss252f:7 i9Cti :01 eeateLeazLT 1,100 s-100a AU3 �MNH WIDNJ ao:CT 2002-22-dae m m d LN M M N tL (n EL Tzra �cLverA sssscn� asrosa► sfw>:e� 9zowam fY f /D7FpS� nay A-u . OWE BRACING DETAIL aI TA a��l7 ear ihi 'alb 'slt rt11 lsl, . 13m RIDE am 7 v WINQ BRACING DETAIL. IX- 2x2.S -ai t 2X2H x ° W-r, COMPONENT SHAPES Y '` .4mrr if ,0 •rs mim fmmwkmegtrz - %WxTtm clafenar�o� %wzT&w ,F- f1fmYU1?efi� 1z28Mfts Cs LPB nrfacwff�erol cu N�►['luefmto[ sv.fx!! Rl�,flif@RQ 'p: <- sufen>rffa 0.4ra ff►2ia M&MIS RIAL �f o ., s7®4s fbsc ELUMM UW»;,Q ML A. - a �B er 9P 9P tP 09 es or er rQ TT rr i r+w rr re Tr rsw or b 2 �t 9fa wr 403' fly wlr fl fd4 17r wir 9XV fif' +itA1R�AH.T 1lfvstUe176W �,a+s'�0'a9lE_ispx Ss, u m BP FTJb9 pTP BP BP 8r Swite wr a a05a a= lT iR P.- I Sr Fis, 9r vp BQ 9r 2+QS 0na aa3D 90 94 &T St R*7 By Q: e9 8T za aam am Tr Fe` Tv rw er Br NP ®fD 93• 39 Goss a vs. vit- 1tf7 fQr fms wr fter wr ft lass O= iam or 117-Pi ww far f34 13110 wr wr 1sc- za ura off ise' Mu, Me WW Sir wr O'Y 7T4D' 1C .W R99 am ft? w'O V'r f3 f7 we I g 21 r ir0 I U Ir � 6IIA aD71 27T 'Ne 23P 23T t" Z�R? itfv 74T �B3 7Tw 2B? 219 o.�D Biw my r ZIP Wa r!O VEI 3!Y Q a3W WW V.V 2MUC 29'1W N? MW 31`9' 3Tr I S7S 3-- MARS a1Pf2 P@flm r -�i Ql1 �a2 •■ t3't� fb f[ S7[.[p rrrif`.ii j p�f�1+ *� VO®E aisSBRi EL s 9SfF[iCo �i3 �fr-r•r." C St68d 8£3f 3s'^196 Famm TYP. ®FAIN! S13i�CE Ottf+-L.:r �. M=0AIR HAVE HWAlirL=KlA"M UULLM9 DETAILS - on SS�TaFffiA7�Ul l.` YB Mt tease+ r.,Sa"14 ILE 7t�11-B0.'�666Y z lOwsm fVf��6f 1.it lC �l3fi4E6alOIMG^"••-"••.�5'�fl �[ ..,�N fL lfM.wf21w 6iPl!!O2/w `�:.. IMF 7EEFi�ABiULUM.ZS�x�7k m �'��u�a.rwo a eefo e►ryz[ NEW M6af� m Sir��-1�wx Fkut—D,• ucT TR=m c fI ERLT!&Gl*�RS� 8 •S Gp ij ffLca3nsfrztfriuef® sas.senz me i� 2z2xmw mw�aa® 44ES m 'a.4 frzrnn.� as z,ta�9 �w Ca®1Pra�fg � . PROF 1`EMdAW12'S&1 :2 ` a w:■s„frro> a:xEm 3 COR9c 1z r2ro mw n;SCT( w�i @C-.Mws 2za � amivs� F _VWWW "°� asam riff:Al��eeO �: 141Y:I[Ml� �) BLSfE�BIi 2fii�►SWHCAR�ft�S7ffir® LL H67>•6o�>tZfa EYE 2z2EOtft toAr rax�.$nlnE s� acs�afwr AHZY�6-AILDA[fJl[tDf[�•7iilN7t --x�r�11'L li F*MMa1Y z /:zf, fsafnF ["R618�-xs[uraxirr[.rorx�t•Ta \7�5•�1xY. PILED vs.2vruaratw».f a�malm aW3 / »2+miar,P 4931 tFJ�S7c�lvt�sis�t:�o�s�[� f � wjdmt» srl,�Al[ff •a'31[QFIAO S7� LIOS:KlB lfz2f?!!r. _ s�P 7<Z#esAoxAtla ' a+pf Ofp fOi [~oev o' 9Y "'®`m""6. 82 e.s�raar.t-whLmcslg llvNBri; a/16s��9aC i�ac�c�scr _ 2f?IIR. Y(tiTAOS��F/RiD�±S1AftOp[•'lenaaolix�suz zf � t a - fDs � �� Y67it9Qd91Y>YaFitIII�REaiIF�RIiIY IYIIEJ►SIl/RtililD eTz,�9a 9Y.�O • �IEEJLS?aiLfWl®8.27 YI9EIL91 SYldr e _ � - a fRs�ewCOfov� tirD�ICf3i61�f®a®1xRHtIPaH1l]flglESRSL acaot� as�va�alr t$».Efs11�Q7fb[I SaEM4tIIQfr-a 3�>L SJ#�&7CbiflDS>7S9f71E HREE y�f2YiitG>® [ar=B�R �[7?}a[mS � 1n � SAiS 1Sat�1MfH�F3f,�1�1>®OIYdrQMliII�6 7!-f BRII'��iYl a'2 VjB� fox ftrr !T fYSfi [F IOC3�m12[® INQIE'ZFl�DIGS:itLililK OF[9IffitlDf:lEgSiB� � 16triiL .A2L9�C 1�-� 1�� virECDI!zY� f OYQ9IC-11fY�r a�F,�-`mot•&��i1 6S��CYI[LEMrt201 fF/ `¢� LIS fSE 4l�(�NM6FZ�AGJL1Q�16MIM:La� raflDZPfBQ 1� s,ife[i�araaa ices STAlid�ll�Ii�Li1C 09M WMXPAYEM �z►iamsauw:grro��.�r v�.a,<v. sUi>lsa[f[aef�� IMLw8f/0Lfw12'z/L IMIYAM UMEMUMPfS'lE10.�3 f[u�c mum-pimAii.liM2M2x59it� t101Ai�LS�4TGFZs 21N+ME96FAMEDIP ETWIX25��t t�LY r cat+z�a+a����a�n4aa�rF FRA1EA1sDAGA9L#E-C3CRMUBCCTUEEWMMMIMWEILMNATDWMI ii WMSMFAVROMREAM TO COWMN TO )UNDATION �tR�>atsa9o��t 9ME�iH3 W 9E�(lfdOf.W,At i0E1f.6210t01Bf[E34+DII NiH�T 11wD LQ6ilS#K S�bi� F&: NlIB1A'aB0Rf7O1 A 7}L�� �1.�^yam Rl.�'�Ji�dR�18-7�BB.3'. xtSmisfpl Qmaaii Tn FacreaA mai i nrtf•--f ��AA 1Sii f 3'x3'X.032'PLATE 2x2H ROOF W/ 4 010 % EACH/PU ,/BEAM PLATE x 2 COLUMN 2x2H2x2H �O3RfIYPJ • COLUMN Xr 1RA. K4WACING PC. 3' x 3' X .06r PLATE W/4 #107W EACH PLATE7 / 2X2H 11 x 2 IIYPJ m 3'X7'X.00Y PLATE W/ 3 #10 Tw IN COL t COLUMN 11140 N L7NA@ RAILAND N EA. K-BRACING PC. SECTION 'B - B' 3'x3'x.062'PLATE W/ 4 #10 TEIS EACH PLATE CORNER COLUMN SECTION °A - A' INTERNAL 3/1 r PLATE, 2 x 2 H PURUN NiERA1N 3M8' PLATE - EACH HALF OF HICFN (TYPE TIP EACH HALF OF EAf2l BEAM M... VARIES�#1418 PER PLATE #14 TEK SCREWS TIP 12 PER PLATE TYP, BEAM SPLICE FOR BEAMS 2' x B• AND LARGER rj.rw 2 x 2 H OWRLIDFD T GUTTER INSERT 10' LONG W. Ell BEAMS V4' x r LAG SCREW OR /#14 TE(, TYP 2 Ell SLDE OF BEAM 1X2ANGLd Ix210PWNAL1rx3'x.12RPANGLE TYP. BEAM SPLICE o"mSPUME WDEOFBE M SPLINE GROOVE SIDE OF BEAN STRUCTURAL GUTTER FOR BEAMS UP TO 2' X 7' OPTION #1 THESE PLANS HAVE MEN REVIEWTRUCTU RAL T"P�'" BEAM 1x2 IN ACCORDANCE WITH THE AMpa rxrx.1251ANGLE W/4#10 • TEICL TVP. HIGH SIDE OF BEAM V4' x21/r LAO SCREWTVP. I jp EACH SIDE OF BEAM Q' x V AND SMAUHO ale' x 21/r LAG SCREW W x T MID IARCBO 1' FASCIA W/ 2' SUB -FASCIA TIP SWJ33R ROOF SEAM 1x2 rxrx.12PMMEW/4010 • MM TYP. HIGH SIDE OF BEAM V4' x 21r2' LAO SCREN TYP.1 EACH SIDE OF BEAM C2' x V BEAMS AND SMALLER) 3AP x 2 Vr LAG 2' FASCIA SCREW lr x T BEAMSS AND LARGER) TV SCREEN ROOF BEAM 1x2 rX7xA2WANLXEW/4#10 • TEfS, M. EAW SIDE OF BEAM VW X 2 Vr LAG SCREW TVP.,1 EACH SIDE OF BEAM (IF WALL. FASTI3NER SIALL BE 1/4, x 2 Vr TAPCON ORTHl1NDER-BOLT). FOR NOTE: FOR WOOD FRAMING. AT LEAST ON r x 6' BEAMS MID SMALLER. FASTENERS OF THE LAG SCRI?WS MUSE ANL?ROR INTO RIAl1 BE Wr DU. FOR r x T BEAMS A SND IN THE WALL FRAMING. AND LARGm WOOD FRAMENASONARY BEAM TO EASCIA/VVALL WALL DETAIL rxrxmrmi SCREEN ROOF W/ 2 010 TEIS IN BEAM Mm 2 #10 TELS NCOLLIMN 7::,6m-s1NO. nYP. EA. BEAM) ,24'O.C. MAX. 5) rx3'x.093'ANGLE 2x2HROOF, W/ 2 #10 TEILS N PURUN SIM AND 2 #10 IMNCOLUMN 1x2--' GYP. FA BEAlO 2x3SIIlLP� rX25' •X.12ANG E 8M1J W/ 3 #10 TELB, TYP.. 1 Ell NDE OF LOAD BEARING COLUMNS L 2' MN_j OYPJ 1x2 •..,_ Tw QTV 2 x 2 S - ComPONENT- SHAPES BEAM) ; 1/4, x r LAG SCREW OR I#14 TEf, TV 2 Ell SIDE OF BEAM ROOF BEAM n. BEAM AND COLUMN SCHEDULE RIKHM L/BO MAX. (140 MPH, EXPOs.'B7 DIMENSION ROOF PANEL WIDTH VS BEAM SPAN DESIGN PRESSURE -10 PSF So Tf TIN 8' 0' 7' 6' 7' 0' 6' 6' 6' 0' Y 6' Y Cr 4' 6' 1 4' 0' 2T2 H 0.050 10.050 6' 0' 6' 1' 1 6' 3' 6' 5' 1 67' 6' 9' 7-0- T 3' 7' 8' 2X2 S 0.050 1 0.050 66' 6' 7' 1 6' 9' 6' 11' 1 T 1' T W 7' 7' 7' 10' 8' 2' 2X3 0.050 0.050 Oil' 91' 9' 4' 9' W 9 1D' 101' 10 5' 10 9' 11' 3' 2X4 0.055 0.055 11' 6' 11' 9' 12' 0' 17 4' 12' 8' 1 IT 0' 13' 5' 14' 1' 14' 6' 2X5 0.055 0.055 14, 9' 15' 2' 1'6' 15' 10' 16' 3' 11& 9' 17V 17110 18' 8' 2X6 0.130 0.055 1710' 16 3' 198' 19' 2' 19' 8' 20 8' 2011' 21' 8' 22' 6' 2X7 0.153 0.071 22' 5' 2211' 23' 6' 24' 1' 24' 9' 25- 5' 26' 3' 27' 2' 26 3' 2X8 0.226 0.074 275' 28' 0' 2V 8' 29' 5' W2' 31' 1' 32' 1' 3331 34' 7' 2X9 0.320 0.077 301' 30 9' 31' 8' 32' 3' 3328 5V 1' 35' 3' W6' 1 37' 11' 2X10 0.390 0.092 3T 4' 134118 1 34' 11 38 9' 36' 9' 371 10' 39' 0' 40 5' 42' 1' DIMENSION WALL PANEL WIDTH vs COLUMN HEIGHT DESIGN PRESSURE -10 PSF SIZE Tf Tw B' On 762 TV 661 6' 0' 562 5' 0' 461 4'(r 212 H 0.050 0.050 4191 Was S' 2' 5' 3' ' 5' 971 T 9' 6' 0' 6121 2X2 S 0.050 0.050 P 4' VS, 5' 7' 5109 5' 10' 6' 0' 6' 3' 6152 6' 7' 20 0.050 0.050 T 4' 76' 78' 7' 10' 8' 1' V 3' 8' 7' 8' 10' 9' 3' 2X4 0.055 0.055 9' S• 9' 8' 9' 10' 10 2' 10 S' 10' 8' 11' Cr 11' T 11' 11' 2X5 0.055 0.055 12' 2' 12' P 12' 9' 13' 1' IP 5' 13' 1 14' 3' IN 9' IV 4' 2X6 0.130 0.055 IV 8' 15' 0' 15' 4' 15' 9' 102 1 IV 6' .47' 2' 1T 10' IS'S' 2X7 0.153 0.071 16 5' 16 10- 19' 4' 19' 10' 20 4' 2011 21' 7' 22' 4' 23' 3' 2X9 0.226 0.074 22' 7' 23' 0'. 23' T 2422 2010' 25' 7' 26' 5' 27-4' 28' S' 2X9 0.320 0.077 24' 9' 25' 3' 25' 11 26' W 27 3' 29 0' 29' 0' MY 0' 31' 2' 2X10 0.390 0.092 127152, 29 0' 2V 9' 29' 5' 30 3' 31' 1' 32' 1' 33' 3' 34' 7' IF GUTTER WAS W/ 4 NO 7B4i; 9 'J?LINE GROOWIE SIDE OF BFA► - a ^3�. BIJCTURAL CUTT ER A, ,� 4$ a NN nPTION 42._ �; 1 '� �� 40. 2 DETAIL 71:W �l F :,,W/2Axa=N BEAM AND 2#10 TEIS IN COIiIIN XEEN ROOF TYP. €A. BEAlA) 3EA4 2 X 2 H ROOF PlIR1N / #105.MS.,24'O.C.MAX! 1x2 ' L7l: NOTE NO. 5) `x • ROOF BEAM OVERIAA 2 x 3 SCREEN ROOF BEAM 10 S.M.S., 24' O.C. MAX TN NOTE NO. 5) ROOF BEAM OVERLAPS C OU MN W/ 3 012 TEILS EA. SIDE OF BEAM r x rx.125' ANGLE W/ 3 040 TEKS, TIP., 1 Hl SIDE OF LOAD BEARM COLUMNS 21/7 THM NTINL.00I u BtXJC PAVERS 3/r SiIM ANCHOR OR TAP j'.DNWfWW aNCFIDRORTAP CON W/ MN. BNCRETE T S113 VEANCHORORTAP d•.CON W/ MIN. B2BEOMBRT T3idHOMHRT OF 2 Vr N CONCRETE OF 21/2' IN CONCRETE OF 2 Vr ..R CONCRETE CYP.,1 EA. SIDE OF ITYP..1 EA. SIDE OF 1050 Com 10' ONR.) OYP.,1 E:- SIDE OF 1 #50 mw 10' ami LOAD BEARING tXIiUMN9 1 #50IDNL 8' (MIN.) LOW BEARING COLUMNS) LOAD OWING COLUMNS STANDARD MONOLTHIC FOOTER ISOLATED/ADD-ON FOOTED- J'C' NT.) BRICK PAVERS NOTE: ALL UPRIGHTS 2 x 5 AND LARGER REQUIRE A SECOND SET OF 2 x 2 ANGLES INSTALLED INSIDE THE 1 X 2 SCREEN FRAME AND AGAINST THE CONCRETE DECK, TO BE INSTALLED IN THE SAME MANNER AND WITH THE SAME SIZE FASTENERS. BEAM TO COLUMN TO FOUNDILTION DETAIL NML- ANY OF THE ABOVE ATTACHMENT DETAILS CAN BE USED IN ANY COMBINATION,iv r: r AS DETERMINED BY SPECIFIC JOB SITE CONDITIONS. CDUAN W/ 3 #12 TE & QROLi Hl :ODE OF @.FAM Wx, rMIN rX:l'X.125'ANIf2E fTYPJ W/ R• lmo 7E6, TIP., 1, 1 H,. SIDE OF LOAD 1011NO COLUMNS "�WUIRED"ANY cOgREC °GENERAL NC ,szNE "F�R©,NspECTogTI L 1. DESIGN COMPLIES WITH THE FOLLOWING PY THE FLDMDA BUILDIN CODE 2001: IC'` & �,� A SPEEDj B. EXPOSURE CATEGORY e'B' C. DESIGN PRESSURES: ROOF:10 PSF WALLS: IB PSF D. MAXIMUM ROOF HEIGHT - 30' 0' E. ALLOWABLE DEFLECTION - L/ 80 F. CONTINUOUS LOAD PATH PROVIDED 2. MATERWS (UNLESS OTHERWISE SPECIFIED) A. EMUSIONS - ALUMINUM ALLOY 6063-TES 8 3003-HI6 B. FASTENERS - ALUMINUM AUDY 2024-T4 3 7075-76, CAD PLATED HOT -DIPPED GALVMUM STEEL OR 300 SERIES STAINLESS STEEL C. SCREEN CLOTH - VINYL =70, WOVEN FIBERGLASS, 60% OPEN OR GREATER 3. 9OLT AND SCREW FASTENINGS THROUGH AN OPEN EXTRUSION INTO SLAP, MASONRY OR WOOD FRAME WALL OR FASCIA MUST HAVE A 50 DLA. HEAD OR USE #A Wr DIA. WASHER, 24' MNGMUM SPACING. 4.'AIND BRACING IS NOT REQUIRED WHEN AN ENCLOSURE 5 FULLY SUPPORTED 0.4 TWO SIDES BYTHE HOUSE. S. ALL SPECIFIED TIE DOWN ANGLES ARE REQUIRED ONLY ON COLUMNS THAT ARE SUPPORTING STRUCTURAL BEAMS (UNLESS OTHERWISE SPORED ON SITE -SPECIFIC ENGINEERING). G. SEE SITE SPECIFIC DRAWINGS FOR ACTUAL LOCATION OF WAIT. K-BRACING. 7. ALL DOORS SHALL BE SEF-CLASIING AND SELF -LATCHING. B. PRINTS OR COPIES THEREOF ARE VAUD FOR BUILDING PERMIT PURPOSES ONLY WHEN BEARING THE ORIGINAL SIGNATURE OF THE ENGINEER OF RECORD UNDER HE EMBOSSED SEAL 9. AS DEFINE) IN SECTION 01804.1.4, ALL BUILDINGS NOT OVER ONE STORY IN HEGW AND lffi THAN 400 SQUARE FEET IN AREA ARE F30 MPT FROM ALL FOOTER / FOUNDATION REQUIREMENTS SPECIFIED IN SECTION #1804, SUBJECT TO APPROVAL BY THE BUILDING OFFICIAL OF THE MUNICIPALITY d TWHICIf,I9I p13iMM% BENG APPLIED FOR. LL A0 En 00 S`yAM W � aLw = C- p h_- 0 � C . M in LIJ Z bra N N n C3 z . n Z EB ®in /0� i.i.J