HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE
2.
3.
1 4.
5.
a
ALL INFO_MUSTBE COMPLETE & FILLED IN TO BE ACCEPTED
St. Lucie County Building and Zoning
2300 Virginia Avenue �(;/�
Ft. Pierce, FL 34982-5652NEIj
`772-462-1553
- St. Lucie county
APPLICATION FOR ALUMINUM STRUCTURES PERMIT
PROJECT INFORMATION
S/D NAME: 'r-,,_l `1t_-Y 't'"-4 !—
PROPERTY TAX ID #: 341c
LEGAL DESCRIPTION (attach extra
_ SITE PLAN NAME: .
if necessary):
������� r)(Or aa10 = : 0O 3) ..
PLAT 6. PAGE 7. BLOCK
BOOK NO. NO.
8. LOT
140.
PARCEL SIZE: ACRES/SQ FT. LOT DIMENSIONS
SETBACKS (ACTUAL) FRONT: BACK: RIGHT SIDE: LEFT SIDE:
TYPE OF• STRUCTURE : (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE)
TYPE OF CONSTRUCTION
N=New
A= Addition
R = Rebuild
SG = Slab on Grade
SR = Raised Slab
WD = Wood Deck
DIMENSIONS
SQUARE FEET OF
CONSTRUCTION
❑ SCREEN ROOM
❑ NEW ❑ EXISTING
X
❑ CARPORT/PATIO ROOF
❑ NEW ❑ EXISTING
X
❑ HABITABLE GLASS ROOM
❑ NEW ❑ EXISTING
X
❑ SUNROOM
❑ NEW ❑ EXISTING
X
❑ SHED
❑ NEW ❑ EXISTING
X
❑ POOL ENCLOSURE
❑ NEW ❑ EXISTING
X
❑ M H ROOF OVER
❑ NEW ❑ EXISTING
X
❑ POOL FENCE
Linear feet
❑ ROOF SYSTEM OVER
E TING ACCESSORYSTRUCTURE
❑ NEW ❑ EXISTING
X
OTHER: t 1 — n
�j
5� NEW ❑ EXISTING
X
TOTAL SQUARE FOOTAGE OF CONSTRUCTION
12. VALUE OF CONSTRUCTION: $ ) LlL V
The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to
question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with
similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted
PRIOR TO FIRST INSPECTION.
SLCCDV Form No.: 001-02 Rev. 2119107 d
OWNER. INFORMATION
Kc) NAME: . C,-3,L_J
•
SC \yJ2_V1_a&C
ADDRESS:
CITY: STATE: ZIP
PHONE (DAYTIME): ("M r O t email:
FILL IN NAME AND ADDRESS,BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM
THE OWNER LISTED ABOVE'.
FEE SIMPLE TITLEHOLDER:
ADDRESS:
CITY: STATE: ZIP
PHONE (DAYTIME):'
CONTRACTOR INFORMATION
STATE OF FLORIDA REG./CERT #: ST. LUCIE COUNTY CERT #:
BUSINESS NAME:
QUALIFIER'S NAME: -.-
ADDRESS:
CITY: LUC STATE: ZIP
PHONE (DAYTIME): G-4 QQ FAX NO. email:
ARCHITE(6/ENGIPEEj-
ADDRESS: _;2<2�0
CITY: STATE: ZIP 8---3 to 09
PHONE (DAYTIME) $0
NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR
ROOFING, ELECTRIC, PLUMBING, AND HYAC
ZONING REQUIREMENTS
All such etures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE.
�2 nscaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks
including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan.
El 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for
inspection verification. not required for construction unrelated to storms)
r.
11_� V.
OFFI
CE 1
SECTION
TOWNSHIP
RANGE
MAP NO.
ZONING
LAND USE
LOT CVG %
Additional
Permits
Yes
no
REPORT
CODE
BIMS FEE
MISC FEES
TOTAL FEES
BUILDING &ZONIN VIEW
=
REVIEWS
ZONING
7�1
ZONING/
REVIEWED
PLANS
EXAMINER
misc.
VEGETATION
VALUE OF CONSTRUCTION
USING ICC TABLE
DATE
COMPLETE
INITIALS
PLAN REVIEW SPECIFICATION CHECKLIST
PLEASE PROVIDE ONE OF THE FOLLOWING:
L-2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license.
❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas.
(1) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT
APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF
A SUBMISSION.
• All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger.
o All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists &
drawings.
e The plan view must include all dimensions; the location of the host structure and all materials must be sized and
identified thereon.
• All elevations must be shown, including 4`h wall detail, dimensions and all material must be sized and identified.
• All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"].
• All methods of fastening or other details which are relevant to the design must be identified on the Plans.
• All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"].
• All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must
be sized and identified.
• All ridge beams and super gutter or fascia attachments must be identified.
• All roof pans or composite panels, with gauges and spans, must be sized and identified.
e All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications.
c All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter
20, including 2006 revisions.
• Barrier -railings, if utilized, shall have all'materials, fasteners and height specified and shall have -self -closing, self=
catching gates with picket spacing. ,
(II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE
REQUIREMENTS AND.tRE FOLLOWING ADDITIONAL ITEMS:
(A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding
component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified.
(B) 2 electric schematics;in.accordance:with the N.E.C., if applicable.
(C) Design pressures-, per Table R 301.2 (2), identified on the openings of all Plans.
(III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA
SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE.
(IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE
ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE
FOLLOWING ADDITIONAL ITEMS:
C1) The designer or engineer will state on -all -Plans, which Category -of Design- [3.-1.2]-will-be used, -inclusive -of the definition.
(2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy
calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of
Florida Building Code.
(V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS
(Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE:
(a) A 4`s wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial
number and current owner's name and street address.
(b) That the complete guide to H.U.D. specifications be strictly adhered to.
(c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall
assume full responsibility for both structures' integrity by site specific documentation.
1
f`
CERTIFICATION:
This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a
certificate of capacity, if applicable, for the permitted work.
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO
OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO
ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO
DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE
PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A
CONDITION PRECEDENT TO THIS PERMIT
1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify
that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind
zones established by the county and take full responsibility for complying with the submitted d sign of the structure being
permitted.
2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the
issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and
zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not
otherwise included with this building permit application.
3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of
Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not
exceed the footprint of the structure that was in existence prior to removal by the storms.
R/CONTRACTOR SIGNATURE
STATE OF FLO
COUNTY OF '
The foregoing
Xlmentackrow�leded
before me this,
by
ispersonally
ka=az me or who has produced
as identification.
Signature of Notary
i PC,,, Notary Public State of Florida
m
Tern Lynn Nutter
(SEAL) c� o
�c
My Commission DD398850
or t%0
Expires 02122/2009
IMPORTANT NOTICES:
NTRACTO SI ATURE
STATE OF FLORIDA
COUNTY OF CS-L Lao to
The foregoing i s ment a knowled ed
before me this y of�, 2y
P�6v o is personally
.y to me or who has produced
as identification.
Signature of Notary
=�g,V PL,,, Notary Public State of Florida
Tern Lynn Nutter
(SEAL) t� My Commission DD398850
-7 O, W Expires 02/22/2009
• TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS
BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS
APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION.
• ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED
REPRODUCTIONS ARE PROHIBITED.
• WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER
NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN
ADDITIONAL FEE WILL BE CHARGED.
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
hftp://Stiucieco.gov/ce
Date: 20 September 2007
Job Address: 401 VERADA AVE
Received By: DPELTON
Paid With: CK
Paid By: AVAILABLE ALUMINUM
Receipt
Sign:
Receipt #:
0000057551
'ermit Number:
SLC- 0709-0170
Amount:
$80.00
�redit Card Number:
Check Number:
9603
i�:•'• ,sue,-u.GtG (/OOt /
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
hftp:/Istiucleco.gov/ce
Issued: 09/20/2007 Conf #: 715
Job Location: 401 VERADA AVE
Permit Type: Building (Miscellaneous)
Job Description: SCREEN PORCH IN -FILL FOR SFR
Subdiv: River Park Unit 4
Lot: 44
Block: 32
BUILDING PERMIT
Permit #: SLC- 0709-0170
City: PORT ST LUCIE
Parcel: 3419-530-0044-00013
Page 1
Contractor JAMES MCPHETRES AVAILABLE ALUMINUM INC (772) 343-1034
1362 SW BILTMORE ST PORT ST LUCIE, FL 34983
Property Owner LIDIA ZYSKOWSKI (772) 871-8071
401 SE VERADA AVE
Property Owner JERZY ZYSKOWSKI
PSL, FL 34983
401 SE VERADA AVE PSL, FL 34983
Setbacks Left: Right:
Number of Units: 1.00 Floors: 1
Minimum Floor Elevation:
- Job Value: $ 1,960.00
(772) 871-8071
Front: Rear: Zoning: RS-4
Buildings: 1 Square Footage: 0.00
Flood Map: 28OF Flood Zone: X Elev:
Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code
including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all
requirements of the 2004 Florida Building Code.
NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the
records of this County, and there may be additional permits required from other governmental entities such as water management districts, state
agencies, or federal agencies. s:553.79(10), F.S.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S.
Christopher Lestrange
Building Official
Date
For Automated Inspections, Call (772) 462-1261
For Questions, Call (772) 462-2172
St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and
become null and void if work authorized by such Building Permit is not commenced, having called for and
received a satisfactory inspection, within six (6) months from the date of issuance of the.permit, or if the work
is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of
issuance of the Building Permit.
c -7 o, = O 1 -7 11
FILE COPY
ST. LUCIE COUNTY BUILDING DIVISION
REVIEWED FOR COMPLIANCE
REVIEWED BY
DATE _ .7
PLANS AND PERMIT MUST BE KEPT ON JOB
OR NO INSPECTION WILL BE MADE,
. o
� U
<W.0
LL
t THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS'�-
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
,� 0
COMPLY WITH ALL'APPLICABLE CODES.
II,
SIZE VARIES
POST SPACING
SEE' SECTION VIEW FOR LIMITS ON
SHEET 2
SEE DETAIL 1 SEE DETAIL F2
—' (TYP.)
1v
FILE COPY
a v ° °d ° •HOSTi STRAC°TURE n ° ° d• -°
d °a
O.B.
: i•:'�❖:❖:❖:❖:
OR 2x5 POST/COLUMN
(TYP.)
SECTIONPERIMETER
SELECT ON
SHEET 2 FOR SIZE,MAXIMUM
FSEE DETAIL 3
SPACING, AND HEIGHTS.
SEE DETAIL 4
CHAIR RAIL (OPTIONAL)
K",
. .•
IL
------------
•' • •
•'
W •.
cn
c
J
•v)
= g
uj
`
W
0
3
d
°
}
U
J
Q
II �.
J
Z. O
e
ZO
m
V
t of
p0..
.n
d .. ° 4
a• FOUNDATION' OR'BALCQNY.
d d°.. ^
SEE DETAIL 2 SEE DETAIL F2
SCREEN WALL ELEVATION (W/ GUARDRAIL SEE SHEET 3) (TYP.)
THESE PLANS AND ALL PROPOSED WI
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES,
D❑ KIM
& ASSOCIATES, LLC
CONSULTING
STRUCTURAL
ENGINEERS
3300 Henderson Blvd., Swle 106
Tampa. FL 33609
Tel: (813) 974.5900
Fee (B13) 874-5959
1ev.lDato ""ri Ilon
n .'..�• ISSUED
D r
F 'R.4 97
DO KI ASSO 7E�LL
OAA 2s6B7
3300 HENDERSON BLVD..
SUITE 106
Tampa, FL 3368E
Drawing No. - 060316
SHEET 1 OF 3
NOTE 1: USE 1/4'0 K 2-1/2' LONG LAGS INTO WOOD NOV
AND 1/4'0 N 2-1/C LONG CONCRETE SCREWS INTO
CONCRETE OR MASONRY CONSTRUCTION O 24' O.C.
AND WITHIN 4' OF EACH PERPENDICULAR UEUBER
HOST STRUCTURE ELEMENTS
1'K2' O.B. O PERIMETER
FASTEN PER NOTE /1
FASTEN POST END PER DEIA1L F2
ADDITIONAL GIRTS SWW. BE ADDED
TO MAINTAIN A MAKIMUM VERTICAL
SPACING FOR HORIZONTALS OF 10' O.C.
CIWR RAIL (GIRT) - 2.2.0.0" PATIO SECTION
FOR SPANS LESS THAN 7'-0' O.C.
2x3xO,O44 PATIO SECTION FOR SPANS LESS THAN 9'-0' O.C.
2.4.0.050 PATIO POST FOR POST TO POST SPACING LESS THAN 7'-6- O.C.
AND HEIGHTS LESS THAN a' -a'
2x5xO.O62 PATIO POST FOR POST TO POST SPACING LESS THAN a'-0' O.C.
AND HEIGHTS LESS THAN 9'-9'
KICKPIATE RAIL (GIRT) - 2x2x0.044 PATIO SECTION
FOR SPANS LESS THAN 7'-0' O.C.
2x3x0.G44 PATIO SECTION FOR SPANS LESS THAN 9•-0' O.C.
— SOLID KICKPLATE (OPTIONQ
—FAST" POST END PER DETAIL F2
I'X2' O.B. SOLE PLATE UNLESS NOTED OTHERWISE, FASTEN
TO FLOOR OR FOUNDATION IN/ 1/4.0 FASTENERS.
1-1/4' EMBEDMENT 0 24' O.C. .
..I a.
FOUNDATION
TYPICAL SECTION I SCREEN WALL (WI GUARDRAIL SEE SHEET 3)
(NOT SUPPORTING ROOF)
s, h r^a •'S
D❑ KIM
•
& ASSOCIATES, LLC
CONSULTING
STRUCTURAL
ENGINEERS
•
3300 Henderson Blvd., Suite 106
General Notes and Specirications:
Tel: (8 3FL 744--S o
1. Contractor shell field verify all dimensions before construction and shall notify engineer of discrepancies for Immediate
F.. (813)874-5959
consideration.
RovJDalol
Description
2. Concrete shall be minimum 28 day compressive strength of Vcx2500 psi, and be In accordance with the requirements of ACI 318. -
we
Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 401 and be provided with cover in accordance with Act 319.
�o
ISSUED
If existing concrete slabs/footings are deemed satisfactory, it may be Incorporated Into new slab/footing by observing the
following procedure:
0
a) Clean and scatble all connecting edges.
b) Drill and epoxy embed 05 reinforcing placed P 12' O.C. mid depth. The rebar should be embedded a min. of 7' (using Hill MY
150 Epoxy or Equal approved), leaving 24' exposed to be incorporated into new slab/footing.
Q
3. A11 dimensions are provided by contractor, 00 Kim 8 Associates, LLC have made Interpretations where necessary.
4. The following screened walls are designed to be attached to masonry black/concrete end/or wood frame structures of adequate
structural capacity. The contractor shall verify that the host structure is in goad condition and of sufficient strength to hold
the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an archifecl or
engineer to verify host slruchre capacity.
S. Screen density shall be a maximum of 20 x 20 mesh.
6. Connections using screw bosses shall have minimum (0410x2' per connection unless shown otherwise.
7. Every panel of screen mesh shall be fastened securely in place with spline. Each panel shall be fastened at all sides,
independent of surrounding panels. This requirement shall include purlins and chair/kickplete rails. Screen mesh panels are not
required to be secured to rigid diagonal bracing members. Screen mesh is incidental to the structural integrity of the overall
structure.
Cj
8. Unless otherwise shown, screws shall have minimum edge distance and center-fo-center distances as shown in this table.
C
C-1022 Law Carbon Steel SMS b Self-Drilunq (TEK) Screws [Industry Standard Screws)
C
Nominal Screw Diameter
Minimum Edge Distance :Minimum Center to Center
d
Screw (In) Distance
Z
010 0.18E •/ • y,•
Q L v
912 0.219 •/ • +/ •
a) F-'
CO 0
.. .. .. -
•� 0 W
9. Screened walls are designed to meet the 2004 FBC w/ 2006 Supplement. Project is sited where the basic wind speed is 140 mph
¢ t-
13-sec gust) 1.0.77 for screen enclosures. Exposure C. Design wind pressures are from 2004 FBC. Minimum design pressure is 10
F-
psi. Pressures are based an wind tunnel testing with main wind force resisting system coefficient, GCp, of 4-0.25 for screen
LL C
Z n
roof and 0.7-1.25 for watts.
91 O y
J W
III. All concrete anchors shall be Simpson Strong -Tie Wedge All Anchors or Titian Screws or approved equal.
V (L In
DO KIM a ASSOCIAlrEfS, (LI
CA# 26887 1(
3300 HENDERSON BLVD..
SUITE 106
Tampa, FL 33684
Drawing No. - 060316
THESE PLANS AND ALL PROPOSED WORK SHEET z OF 3
AHt ��6
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
OmmILE COPY
DO KIM
& ASSOCIATES, LLC
' CONSULTING
1Tt2' O.B. PERIMETER FASTEN PER NOTE•/1 STRUCTURAL
�n��,/ ENGINEERS
Em S'""m"E nommY 2x/8 X1/2*
1/ ANGLELON S.YS.GATWrrH
EACH LEG
iLPiCA1, TOP AND BO7EOY 3300 Hendeman Blvd., Slade 106
Tempe, FL 33509
• Q da ~ 4R %f0 S.Y.S. FROM INSIDE FACE OF 1 % 2 O.B. Tel: (B13) 8745900
INTO SCREW SPLINES OF 2 X 2, FeK: (813) 8745903 1• EMBEDMENT MINIMUM
V 2' % 2' SEIF-MATING (OR SNAP) HORIZONTAL (GIRT) RevJDate DBSCN lion
• • Q 1•%1•X1/18 ANGLE 2' LONG WITH d• (TYPICALLY HOLLOW SECTION W/O GUARDRAIL) '. ,t HOST •SiRI1C(Ut� A. . Q IBBUED
2-18 X 1/2• LONG S.M.S. AT EACH LEG
TYPICAL EACH SIDE, TOP AND BOTTOM
0
• Q • TYPd • •,' '
OR 4
2- /10 S.M.S. FROM INSIDE FACE OF 1 X 2 O.B. a Q
DTO SCREW SPLINES OF 1 % 2 O.B. NOTE: IN SCREEN WALLS WITHOUT GUARDRAILS,
1' EMBEDMENT MINIMUM • G PICKETS NOT PRESENT. ALL OTHER
7� ATTRIBUTES OF DETAILS APPLY.
2• X 2' % 1/8• ANGLE
-REFER 70 NOTE /1 - THIS SHEEP EACH SIDE
" • C 1 P D BOTTOM PICKETS H 110EO W/2 FACH /14 S.Y.S. TYPICAL. PERIMETER 1X2 FASTENED 70 HOST Q
TOP AND BOTTOM W/2 EACH j10 S.Y.S. USE/"'
% 2-1/2' LONG NOS INTO
•' 1• EMBEDMENT SELECT COLUMN AND POST WOOOSTAND1//4%%2-1/4'LONOXfl SCREWS INTO CONCRETE1'%2' O.B. PERIMETER 41D kG4.2ITIBY WIND ZONE ON PER TABLEOR ONRY CONSTRUCTION/ 24.. AND
WIT
4. OF EACH PoSi
"G�'` WOOD'NOST AND 1%4%L%"2-N/GS INTO DETAIL 3: CHAIR RAIL CONNECTION DETAIL F2: POST END (TOP OR BOTTOM) TO HOST FASTENING
LONG CONCRETES EWS INTO CONCRETE
OR MASONRY CONSTRUCTION 24. O.C. AND WITHIN 4. OF EACH 1'%iX1/16 ANGLE 2' LONG WITH
PERPENDICULAR MEMBER 2—/10 X 1/2LONG S.Y.S. AT EACH LEG
TYPICAL, TOP AND BOTTOM
OR
DETAIL 1: TOP CORNER CONNECTION SEE ELEVATION FOR SIZE HfOrSCREW*SPUNF"ESM OF52EXF2 E OF POST
U
NOTE IN SCREEN T PRESENT.
ENT. AL CUARDRNLS, 1-1/2' EMBEDMENT MINIMUM C
PICKETS NOT PRESENT. ALL OTHER
ATTRIBUTES OF DEVILS APPLY. 2• % 2' SELFLLOW C SECTION
SNAP) GUARDRAIL)
(GIRT)
(TYPICALLY HOLLOW SECTION W/0 CUARORML) E y
C ID
E o
1'%2' O.B. PERIMETER 3 zNOTE IN SCREEN WALLS WITHOUT GUARDRAILS, SEE ELEVATION FOR SIZE Q O co
PICKETS NOT PRESENT. ALL OTHER � Q
•• REFER -TO NOTE /1 - THIS SHEET ATTRIBUTES OF DETAILS APPLY. PT U
• 2' X 2' X 1/8' ANGLE EACH SIDE
Q Q W/2 EACH 114 S.M.S. N
1O D BOTIOL PICKETS FASTENED
TOP AND BOTTOM W/2 EACH %10 S.M.S.
1'•1' D BOTTOM
W/2PICKETS HFASTERHOED 1• EY9EDMENf 3/8.0 CONCRETE ANCHOR W TD
• TOP BEDMEM M W/2 EACH /10 S.M.S. W/2 •MIN EMBEDMENT F , a
W m
DETAIL 4: GUARDRAIL CONNECTION 1X2 G.B. SOLE PLATE O
v• 1•%1•%18 ANGLE 2' LONG WITH 1'a1' GUARDRAIL PICKETS (L �
TYP X X 1/2' LONG S.Y.S. AT EACH LEG DRAMBY: DYK
to ICAL EACH SIDE, TOP AND BOTTOM OR CHECKED BY: DYK
OR
_ 2- /10 EWS.M.S. FROM INSIDE FACE OF 1 % 2 O.B. * SCALE A88NONW
INTO SCREW SPLINATE: 020/07
ES OF 1 % 2 O.B.0.8.
• 1' EMBEDMENT MINIMUM L•~• ', a•'.
4 NOTE 1. WOOD
USE
D'�OSf AND 7///4%L%2-1%4 INTO '• •. , 4) '
d Q •a LONG CONCRETE SCREWS INTO CONCRETE •
OR LWSONRY CONSTRUCTION f �• • .� . A " 2 EACH /10 SMS % 1-1/2'
• i10'T STRIICIURE i1EMETTIS 4 2C O.C. AND WITHIN 4' OF EACH 4 LONG INTO SOLE PLATE
Q PERPENDICUTAR MEMBER 1/4'/ % 2-1/4' LONG CONCRETE F YE �M ,4
• Q . • NOTE 2: W SCREE" WALLS WTR10Uf GUARDRAILS. ONSCRNECTINC4MEMBER
D WITHIN 8' OF p�/•
' PICKETS NOT PRESENT. ALL OTHER DO I.
00 C.0
ATTRIBUTES of DETAILS APPLY. DETAIL F1: POST TO FOUNDATION FASTENING DAe2
DETAIL 2: BOTTOM CORNER CONNECTION 3300 HENDER II BL
SUITE 108
Tempe, FL 33W
THESE PLANS AND ALL PROPOSED WORK Drawing No. - 060316
ARE SUBJECT TO ANY CORRECTIONS SHEET 30F3
REQUIRED FAR6 T1i�17
MAY BE NECESSARY IN ORDER TO
CQMPLY WITH ALL APPLICABLE CODES-
Building
. _.....�. =
Code Compliance Division : Receipt
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
http://stlucleco.gov/ce
Date: 14 September 2007
Job Address: 401 VERADA AVE
Received By: gersteml
Paid With: ck
Paid By: available aluminum ine
Sign:
Receipt M
0000057409
ermit Number:
SLC- 0709-0170
Amount:
$50.00
redit Card Number:
Check Number:
9539