Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
OFFICE Date: Due: Receipff Permit # D ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED [T St. Lucie County Building and Zoning SCA 2300 Virginia Avenue /GAton FQ, �Yp� � AIAXe. �V�e&) Ft. Pierce, FL 34982-565 LucieBy 772-462 1'ss3 ? PD.vC'. �P-�So�j AZ00 count. APPLICATION FOR ALUMINUM=T•RUCT�I�J`S ERMIT PROJECT INFORMATION I. LOCATION/SITE ADDRESS: 45q ®O ej tls �W7 2. PROJECT NAME: SITE PLAN NAME: ty-M I Ida LSICLtC 3. PROPERTY TAX ID #:- 4. LEGAL DESCRIPTION (attach extra sheets if necessary): k R�ANks 45' 12:) V'bLrcIe k a L \ . "Aa.\ Pyc> . [©�— 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK —� NO. NO. �Io 1 ��� • 20� 9. PARCEL SIZE: ACRES/SQ FT. 2 LOT DIMENSIONS45X MOM X 222)(151._to V 1AT 10. SETBACKS (ACTUAL) FRONT: ?5 BACK: 2 RIGHT SIDE: I 1 LEFT SIDE: 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X POOL FENCE Linear feet TOTAL SQUARE FOOTAGE OF CONSTRUCTION 12. VALUE OF CONSTRUCTION: $ The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rem. 2119107 d OWNER INFORMATION NAME: ADDRESS: lP 11 Z. CITY: �� ��e C� STATE: ZIP�Q PHONE (DAYTIME): ( ) EMAIL: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): O CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: ���iP�I �lP 1 ST. LUCIE COUNTY CERT #: r,-1 C) BUSINESS NAME: QUALIFIER,1' S11 NAME: '1 O'M ADDRESS: 49- <D \ S S CITY: 7 �& Z) �e Z e STATE: a- ZIP Q PHONE (DAYTIME): (1�1a� �lt�ly 09 i3 FAX NO.-T-Q - 440(0 ' ]0 -14 email: ARCHITECT/ENGINEER: W\-Um umun., JC�Cc�'rt9—��- �I �,►CV"L- ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): ( ) NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) OFFICE USE ONLY SECTION (A TOWNSHIP 365 RANGE 'T DE MAP NO. i j�/� ,'Y y, Id�l � Additional ZONING AR _J LAND USE F%�-I LOT CVG % Permits Required REPORT FJ BIMS FEE MISC FEES $ TOTAL FEES CODE BUILDING & ZONING REVIEW FRONT PLANS VALUE OF CONSTRUCTION REVIEW COUNTER ZONING SUPERVISOR EXAMINER VEGETATION USING ICC TABLE DATE COMPLETE �� INITIALS - +^' CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the ContracJtor / Owner Buil , Record and is)n adequate Spudlition to OR CONTRACTOR SIGNATURE STATE OF FLORIDA COUNTY OF,---* kXXA C ,e herified that the existing foundation meets he requirements of the Engineer of �hstand the uplift and weight of the alumin and said structure will not was in existence prior to removal b rms. CONTRACTOR SIGNATURE The foregoing instrument was acknowledged before me me this I day of , 20a_ , by " SlO- I(yX 1ClA cs, who is personally known to me, or who has produced as identification. STATE OF FLORIDA COUNTY OF�� The foregoing instrument was acknowledged before me me this q day of 11-o✓ , 20 0 by L`y Q rU VANLC tte� > who is personally known X_ to me, or who has produced as identification. 01\kny7�h� &S,WNtl1�t N K- (_Seal) Signature of Notary '�tate of Public, Florida Signature of Notary CHRISTINA BROWN Notary tesFeb.17,2009 Notary Public, State of Florida IMPORTANT NOTICES: CNo DD397778 My Comm. Expires Feb. 17, 2009 No. DD39777S • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR, IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION, TO SIGN THIS APPLICATION & THE OWNER/BLDR AFFIDAVIT. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL, SIGNED IN INK. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE -BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL, BE CHARGED. i PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: ❑ 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x I I" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4'h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, gins, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED, SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4`h wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 hftp://stiucleco.gov/ce INSPECTION CARD Permit #: SLC- 0709-0159 Conf #: 546 Type: Fence Issued 09/27/2007 Status: FIN Double Fee: No Job Location 5900 CITRUS AVE City: FORT PIERCE Jurisdiction: St. Lucie County Lot: 2 Block: Parcel: 3409-504-0003-000/2 Subdiv: Flood: X Elev: Flood Map: 28OF Job Description: CONSTRUCTION OF ALUMINUM RAIL FENCE AROUND POOL (PO# 0709-0158) Setbacks Left: Inspection Notes: Right 91.31 Front 75.00 Rear, 12.00 Contractor WHIGHAM GARY K SOUTH FLORIDA ALUMINUM PRODU( (772) 466-0913 4801 S U S 1 HWY FT PIERCE, FL 34982 Property Owner DAVID C RICHWINE (772) 465-6465 6112 YUCCA DR FORT PIERCE, FL 34982 Property Owner PENNIE P RICHWINE ( ) - 6112 YUCCA DR FORT PIERCE, FL 34982 SUB -PERMITS Permit # Status PT Cert # DBA Owner / Builder Job Description INSPECTIONS - For Requests, Call: (772) 462-1261 Permit # Code Description Priority Date Sched. Res Description Inspector Date Insp. 0709-01M 110 Footer/Foundation 1 92 Accepted As Noted Greg Smyth 01/11/2008 job is finished posts seem anchored in place cannot see footers without a destructive inspection fence would fall down null Resulted: Fri Jan 11 11:36:34 EST 2008 0709-015£ 999 Final Inspection 1 01/11/20Q8 99 Final Approval Greg Smyth 01/11/2008 null Scheduled: Thu Jan 10 13:18:23 EST 2008 with value: Fri Jan 11 00:00:00 EST 2008 Resulted: Fri Jan 11 11:36:57 EST 2008 Perms mit Nln7nG-nl.r,9 COASTAL TESTING LABORA-WRY, L.L.C. PO BOAC 2023 PALM CITY, FLORIDA 34991-2023 772.220.6688 COMPACTION -rEsr POl - ASTM D 2922 -05 rDArE JOB NUMBER PERM1r NUMBER CLIENT CON- RACrOR JOB LEGAL JOB AVO ESS Nove,wa)pr 12, 2007 07-1109 0709 -0158 Louden. Pootk Lou le4i/ P0044- N/A 5900 Citru%Avemwl Fort PLercels FL RECEIVED NOV 1 4 2007 BY:. SOIL CLASSIFICATION Er REMARKS A3 Fi rwv browev Sa#L&y Wa, wi-3v a- woderate,a*naunt0f clay TEST'SAMPLE LOCArIoN : 10' IS LR Carmu, - Center of Pa l - 10' IS RF Corner IN PLACEDRY DENSITYMAKWUM DR DENSl Y COMPAC71ON 1) 102.2 103.8 98.5 2) 101.4 103.8 97.7 3) 101.8 103.8 98.1 RESPECTFULLY SUBMITTED CA ERNESrO VELASCO, P.E. a 1 COAS7'AL 7ESrINO LABOIZA7'ORY, L.L.C. PO BOX 2023 PALM CITY, FLORIDA 3499I -2023 772.220.6688 MOISMIZE DENSITY RELArIONSUIP ASTM [D .155 7 -02EI DATE CONrRAcrOR JO-6 NUMBFR PfRMIr NUMBER IIE 917 November 12, 2007 Loud,e,w Poo�k 07-1109 0709-0158 el I. ij id Moisturc — Percent of ilry Weight .1, .1"ASTAL TESTING LABORATORY P.O. Box 2023 Palm C4 FL 301.2023 is , ST. LUCIE COUNTY BLDG. DEPT. 2300 VIRGINIA AVE. FT. PIERCE, FL 34982 IIIII I Ill III 11111th III fill Address` 5900 CITRUS ', AVE-� Owners) . �DAVID C RICHWINE� Un City 1 State,hZiR FPR . • FC 34982u. Parcel # 3469-tQj-0003-000122 )urisdict'ion CTY Zoning AR '1 ; ; ot,#, . . uture Land Use Residential Urban Subdivision Amagal Estates Block C APPLICATION•- • •Permit Type Fence =� � ) t ' 0709-0Tv9 app)ication'Type _ Buil'dmg 'Permt,w/o'su'bs' 0ther t Issued Activity Type Addition: Stones ` I I �toroatic SpnnRler System? (� ; i FEES A•• - Pay Fee ,Code', Type •;+' ` ' Account +;• , _ o , . °° Quantity • ,Amount pate:Posted Paid?` Now? BIMS651'-, ' 06-BIMS 491 2415 322050 200 $5.00 0912t'/2007'. Q f BIMS651 06-BIMS wa'r �ro e 491'24153 2050,200, "15 .,, $5<00 a 09l271 007 e Yes i Perm�703 06•Permit Fee Fence (1&2 Family F 491 2 322000 200 $75.00 09/27(2007 .Yes �M a Date Entered` p9725l2007 Date Paid 09127l20067 _ Entered By' ciciok Historical? No •. Receipt# Amount 'Date Posted . 0000057716 $80.00 09/27/2007 Paid B y;; SOUTH FLORIDA ALUMINUM a y Payment Type CK •;• -` .Check'(6k Cash'(CA), Check # 1814 p. Mastercard (MC),:Vjsa (VS} Fee } Waived (i"l+V), Refi�ntl (RF)' L Credit' rd'Number Reversal'tf2V) credit Card Authorization Issued To SOUTH FLORIDA ALUMIUM PRODUCTS IP Received By gersteml. Date Paid 09%27/2007 . loll . sa oo o 0o _ d I To refresh the balance pleases click they !Refresh,Data' button at the top of the°dorm % Ems✓ E e ...,....>»........................e....«.....,........,........._....�...w.........,�.._+....,.a..«...k.w..«w......w...,ww...�..«,.—+...t..h,..:... .............�......,...w.M.w.h+.`.....................w-.....,......--...�+.«......:..�.b.:...J»...........:,.......+..-,,....+........:....w.,_v._.. Building Code Compliance Division Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stlucieco.gov/ce Date: 27 September 2007 Receipt #: 0000057716 Job Address: 5900 CITRUS AVE 'ermit Number: SLC- 0709-0159 Received By: gersteml Amount: $80.00 Paid With: CK �redit Card Number: Check Number: 1814 Paid By: SOUTH FLORIDA ALUMINUM PRODUCTS Ir Sign: Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 hftp://stiucieco.gov/ce BUILDING PERMIT Issued: 09/27/2007 Conf #; 546 Permit #: SLC- 0709-0159 Job Location: 5900 CITRUS AVE City: FORT PIERCE Permit Type: Fence Job Description: CONSTRUCTION OF ALUMINUM RAIL FENCE AROUND POOL (PO# 0709-0158) e Subdiv: Lot: 2 Block: Parcel: 3409-504-0003-000/2 Page 1 Contractor WHIGHAM GARY K SOUTH FLORIDA ALUMINUM PRODU, (772) 466-0913 4801 S U S 1 HWY FT PIERCE, FL 34982 Property Owner DAVID C RICHWINE 6112 YUCCA DR FORT PIERCE, FL 34982 Property Owner PENNIE P RICHWINE 6112 YUCCA DR FORT PIERCE, FL 34982 (772) 465-6465 Setbacks Left: Right: 91.31 Front:75.00 Rear: 12.00 Zoning: AR-1 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: 28OF Flood Zone: X IElev: Job Value: $ 0.00 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Property Appraiser - St.Lucie County, FL Page 1 of 1 PROPERTY RECORD CARD David C Richwine Record: 1 of 1 <<Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification Site Address: 5900 CITRUS AV ParcellD: 3409-504-0003-000-2 Sec/Town/Range: 09:36S:40E Account #: 159982 Map ID: 34/09N Land Use: UNCLSFD ACRG Zoning: AR-1 City/Cnty: ST.LUCIECOUNTY ..,'=m„Rrf Ownership and Mailing Legal Description Owner: David C Richwine Pennie P Richwine AMAGAL ESTATES (PB 45-12) PARCEL 2 (1.421 AC) (OR 2336-2166) Address: 6112 Yucca Drive Fort Pierce FL 34982 Sales Information Assessment TRIM Total Land and Building Date Price Code Deed Book/Page 2007 TRIM: 49800 Land Value: 49800 Acres: 1.42 8/15/2005 25000 00 WD 2336 / 2166 Assessed: 49800 Building Value: 0 10/9/2002 85000 00 WD 1608 / 1390 Ag.Credit: 0 Finished Area: 0 SgFt Exempt: 0 Taxable: 49800 Proposed Tax: 940.55 BUILDING INFORMATION No. Sk-, - tc, h Available Auail=ab� Exterior Features View: RoofCover: RoofStruct: ExtType: YearBlt: Frame: Grade: EffYrBlt: PrimeWall: - StoryHght: - No.Units: SecWall: Interior Features BedRooms: 0 Electric: PrmintWall: - FuI[Bath: 0 HeatType: AvgHUFI: 1/26ath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qua]. Cond. YrBlt. No. Land Use Type Measure Depth 1 9900-UNCLSFD ACRG N -Acres 1.211 2 9900-UNCLSFD ACRG N -Front Ft 45 200 THIS INFORMATION IS BELIEVED To BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. MIN. SETBACKAEQ. FRONT F�O SIDES CNR SIDES REAR 3 D ZNG. - TECH. hftn•//www nnclr nrv/nrr. acn9nrnlir]=IA 05(lAnoo*infl(17 0/1Al,)o 17 a IV1S1©t� 11�5PRCT1® r 7 - HANDRAILS AND G ialilt �� D RMU�CIS INCLUDE AILS. ALU�AI�U P AND cow4f-C�1�DNS ANS DET VtS1Et C(OtINEC1I®N ptt HIDD��E,��E RESP®t�s � ®R. D�ip1LS C0141RN r MUSrBl�l Pd0 lNsp KE�'T 0, JO SEE TABLE FOR MAX. SPACING �TION KI13 OR LL BEgq De FOR 42" AND 48" HEIGHT.j ,.,_.�� _' _._ '10 X 1 1 /2" SCR AT EACH PICKET - 2" X 2" RAILING POST PICKETS AT 4 ON CENTER — #10 X 1 1 /2"..1 SCREW AT EACH PICKET z �N•1, w `fit J 0 a ({ TIC RAIL BOTTOM RAIL SET POSTS INTO F8,000 P.S.I. GROUT (TYP.) t -CONCRETE SLAB j a. • a .Q a 3" TYPICAL RAILING SECTION REFER TO PAGE 7-3 FOR ALTERNATE 01 (� POST BASE CONNECTION DETAILS t �Ql� sr. Lucl BUILDING DIV J,1,y MYEo N DATE TYPICAL RAILING ELEVATION TABLE #1 (FOR SWIMMING POOLS ONLY) RAILING HEIGHT PICKET SIZE PICKET SPACING MAX. POST SPACING 42" 3/4" X 3/4" 4 5/8" O.C. 5'-6" O.C. �4� 3%4" X 3/4" 4 5/8" O.C. 5'-0" O.C. 60" 1" X 1" 4 7/8" O.C. 4'-6" O.C. TABLE #2 (FOR BALCONY RAILINGS) 50#/L.F. POST TYPE PICKET SIZE PICKET SPACING MAX. POST SPACING Q 3/4" X 3/4" 4 5/8" O.C. S-4" O.C. © 3/4" X 3/4" 4 5/8" O.C. 5'-0" O.C. © 1" X 1" 4 7/8" O.C. 5'-0" O.C. NOTE: ALL BALCONY RAILING TO BE 42" HIGH. NOTE: SWIMMING POOL BARRIER E INTENDED INDICATE RAILINGS FENC NGANDBALCONY RAILINGS,E TSUITABLE H EXTRUSIONS OWN MAY NOT BE SUITABLE FOR HANDRAILS FOR STAIRS, REFER TO _FBC, 1007_5. FIL 1":22 COPY AAF Guide to Aluminum Construction in High Wind Areas Page 7 - 1 0 0 N ' f® Chapter 7 - HANDRAILS AND GUARDRAILS 1.50" 0.05" 0 0 1.80" .085" in rn 1-625" �- 0.145' I L11 1.000" 0.8�/5" I BOTTOM RAILS REINFORCED WITH I -BEAM INSERT 17 n n " 2 X 2 RAILING POST NOTE: 1=BEAM REINFORCING TO BE PLACED AT THE BOTTOM OF E POST AS SHOWN (21 " LONG.) 7� I o .040" 1.00" .040" 0 0 PICKETS FILE %.,OPY l l,e.Aluminum Construction in • , Chapter 7 - HANDRAILS AND GUARDRAILS 2.49 N 1.29 0.06 2. 02' 00 2.00" N � t\ e 2.50" 1.80" o- 1.80" �r J TOP RAIL ALTERNATES NOTE: CHAPTER 7 SPECIFICATIONS ARE INTENDED TO INDICATE RAILINGS SUITABLE FOR SWIMMING POOL BARRIER FENCING AND BALCONY RAILINGS, EXTRUSIONS SHOWN MAY -NOT BE SUITABLE FOR HANDRAILS FOR STAIRS, REFER TO FBC 1007.5. c 0 N 0 0 4 q ."" 1.90" i� � N O 0 2.00" 2.00" O L0 %8110- F' r k s`: Py AAF Guide to Aluminum Construction in High W6n Ar�as _o• Chapter 7 - HANDRAILS AND GUARDRAILS ALUMINUM POST. kCK BITUMINOUS T BASE OF POST. 2 0 X 24" DEEP ;ONCRETE FOOTING. 0 I N a` 1'-0" FOOTING DETAIL FOR FENCING GENERAL NOTES: 1. DESIGN CRITERIA : FLORIDA BUILDING CODE. 2. ALUMINUM TO BE ALLOY 6063—T6 3. ALL HARDWARE TO BE STAINLESS OR CORROSION RESISTANT STEEL. 4. CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 2,500 P.S.I. IN 28 DAYS. 5. THESE SPECIFICATIONS ARE FOR RAILINGS AROUND SWIMMING POOLS ON GROUND FLOOR LEVELS FROM 0' TO 5' (TABLE No. 1) AND FOR BALCONIES (TABLE No.2). 6. ALL GATES TO BE SELF CLOSING AND SELF LATCHING. ♦ 1 �a. J .y` J �f. SC�� � hy•