Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSF, SCANNED BY St. Lucie County Permit Number: v 7,1) S r c)r ,0 0 St. Lucie County Building & Zoning Department 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-1553 APPLICATION FOR STORM SHUTTER PERMIT iffl] C;;� I TWP ; /� I RNG I r/� �I MAP [ylZ� r � �LU INIT I M � y SEE REVERSE SIDE FOR INSTRUCTIONS DATE: 1. LOCATION/SITE ADDRESS: 14 100 m . M I 33 2. PARCEL ID NUMBER: 0 Lk'23 50Z Ono R O O O q 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: J—i►Si a h ClCLord Ib rl 4u e ps Do 2 000-6Or. 4 rol I-u'ps O(1 3 00nI AGS• 4. TYPE OF STRUCTURE: SFR Addition OTHER 5. OWNERS INFORMAATTION 6. CONTRACTORS INFORMATIONr, Name: l` y1 Th) S I / FL REG/CERT #: C Co C Q 75 �—I H MG , l . � ZG Ue I ' 1 Address: ,� k/ � COUNTY CERT #: City: L)U State: �-� . �L Business Name: (�'jv�c��sj�-[�NCTG Phone: \\�,i /�C�/� � (77 g l q-Ca 6— C-2 l Zip. Lt C�Ol �d/� . l3'x) J f -1 S� .. ! a jiP C. Type of Surface attachment: Wood Frame Concrete / V Masonry Other roduct Type Minimum Design Pressure Pro uct Compliance Report # Method of Attachment As per 1707.4.4.1 FBC 120 mph 130 mph 140 mph 140 Exp. C SBCCI- Dade Other Anchor Type Anchor Spacing Impact Glazing Removable Panels Accordion ✓ �� "�G Roll U / 13/ "%r �• Colonials Other ALL PRODUCTS"SHALL BE LABLED SBCCI OR DADE COUNTY FOR DETERMININU IMPACT RESISTANCE FROM WIND BORNE DEBRIS. **SEE FINAL INSPECTION PROCEDURE FOR EXISTING RESIDENTIAL STRUCTURES ON BACK. 7. VALUE OF CONSTRUCTION: $ H-r6o _ FEES DUE: RECEIPT: T OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction nd zoning. '�j Property Appraiser - St -Lucie Cpjinty, FL Page 1 of 1 Elizabeth A Thomas Record: 1 of 1 Property Identification Site Address: 4100 N Al A Sec/Town/Range: 23 :34S :40E Map ID: 14/23N Zoning: Ownership and Mailing Owner: Elizabeth A Thomas Address: 4100 N A1A Fort Pierce FL 34949-8344 PROPERTY RECORD CARD «Prey Next» Spec.Assmnt Taxes Exemptions Permits Home Print ParcellD: 1423-502-0008-000-9 ��4UCeIE COG _. Account #: 8520 y <,.• Land Use: Condo e City/Cnty: ST. LUCIE COUNTY Legal Description TREASURE COVE DUNES UNIT 133 (OR 385-2526 : 1820-2236) Sales Information Assessment Final Total Land and Building Date Price Code Deed Book/Page 2006 Val: 423900 Land Value: 0 Acres: 0 9/28/2003 100 01 QC 1820 / 2236 Assessed: 161026 Building Value: 423900 8/1/1982 218000 00 CV 0385 / 2526 Ag.Credit: 0 Finished Area: 1900 SgFt Exempt: 25000 Taxable: 136026 TotalTax: _ 2723.26 BUILDING INFORMATION cea%imo.� Irr Available Exterior Features 3900 View: Ocean RoofCover: - RoofStruct: View ExtType: X157 - TresCvDune YearBlt: 1982 Frame: - Grade: NT - NT EffYrBlt: 1982 PrimeWall: StoryHght: 0010 - 1 Story No.Units: 1 SecWali: Interior Features BedRooms: 3 Electric: - PrmintWall: - FuliBath: 0 HeatType: AvgHt/FI: STD 1/213ath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth PUNT - PUD UNIT S 1 314000 AV AV 0 1 0400-Condo N -No Land Val 0 0 CLiv - CondoLivArea S 1 1900 AV AV 0 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/prc.asp?prclid=142350200080009 5/24/2007 K,,R-ffN AGbS Cs0 f'00 PRINT QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS O / • DAY OF 6, 2 O IS7OWN TO ME OR WHO HAS —PRODUCED AS IDENTIFICATION. av� b �AVIC R. SOELGN;N SIGNATURE IS N TYPE OR PRINT NAME OF NOT Y Notary J7uOIIC - State of Florioa TITLE: NOTARY PUBLIC COMMISSION NUMBER z "�'u++ � D297641 NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MA tiP ��.S ,���II�7tPAiG r TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FIN ANCNG-'—'---- CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. INSTRUCTIONS Please complete all information in the space provided. All information must be Printed (use black or.blue ink only) or Typed. This application for Shutters to be used for only those activities that is not otherwise included under a primary building permit. This application for Permit may not be used,for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition to the installation of Shutters, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. LOCATION/SITE ADDRESS: .............................................. Indicate the street address, or general location, of the property on which the building activity is taking place. 2. PARCEL ID NUMBER: ........................................................ Indicate the Property Tax Identification Number for the property on which the building activity is taking place. 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY........ Briefly describe the building activity under permit application. 4. OWNERS INFORMATION: ................................................ 5. CONTRACTORS INFORMATION: .................................... 6. VALUE OF CONSTRUCTION: .......................................... ; Indicate the name and address of the owner of the property on which the product is to be installed. Indicate the State of Florida (if applicable) and St. Lucie County contractor's registration numbers, and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. The value of construction is used to determine the amount of permitting fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. All applications for the installation of Shutters are to be submitted to the St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Following the issuance of this Shutter Permit, the scheduling of all required inspections may be made by calling (772) 462-1261. INSPECTIONS ** EXISTING RESIDENCES All shutters must be installed and in place at the time of the final inspection, except for Egress Windows and Doors where one panel must be installed and the remainder must be by the opening for the inspector to verify remaining panels. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stfucleco.gov/ce BUILDING PERMIT Issued: 05/24/2007 Conf #; 841 Permit #: SLC- 0705-0400 Job Location: 4100 N A1A City: FORT PIERCE Page 1 Permit Type: Storm Shutter Job Description: INSTALLATION OF ACCORDION SHUTTERS ON 2 OPENINGS AND ROLL- UPS ON 3 OPENINGS Subdiv: Treasure Cove Dunes - Condominium Lot: Block: Parcel: 1423-502-0008-000/9 Contractor MARTIN F. COHEN GOLD COAST HURRICANE SHUTTER (954) 472-776610 5900 SW 44 ST DAVIE, FL 33314 Property Owner ELIZABETH THOMAS Setbacks Left: (772) 466-6118 4100 N A1A FORT PIERCE, FL 34949-8344 Number of Units: 1.00 Minimum Floor Elevation: Job Value: $ 4,780.00 Right: Front: Floors: 1 Flood Map: Rear: Zoning: HIRD Buildings: 1 Square Footage: 0.00 Flood Zone: Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies; or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR ` BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange 5-oiV-07 Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 24 May 2007 Job Address: 4100 N AIA Received By: HUMPHREYA Paid With: CK Paid By: GOLD COAST HURRICANE SHUTTERS Building Receipt Sign: Receipt #: 0000054411 'ermit Number: SLC- 0705-0400 Amount: $130.00 �redit Card Number: Check Number: PLANNING AND DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulations Division 2300 VIRGINIA AVE. FORT PIERCE, FL 34982 (772)462-1553 PERMIT RENEWAL REQUEST ADDRESS: PERMIT NUMBER: L4,/ V Jy 7 CT AM REQUESTING THAT THE ABOVE PERMIT IS RENEWED FOR 18 MONTHS. I UNDERSTAND THAT I MUST SCHEDULE AND PASS ALL REQUIRED INSPECTIONS FOR THE PERMIT TO BE FINALED. FURTHER, I UNDERSTAND THAT THIS IS A ONE TIME RENEWAL AND THE PERMIT SHALL EXPIRE SHOULD I NOT RECEIVE A PASSING INSPECTION DURING ANY SIX MONTHS PERIOD DURING THE RENEWAL PERIOD. STATE OF FLORIDA, County of BEFORE ME THIS C9 / DAY OF LET 7h ® W)46 IS PE FOR OFFICE USE ONLY: RENEWAL FEE: $ No. of Open Inspections _ Total No. of Inspections = wiz 20 4P° ALLY KNOWN TOME , OR AS IDENTIFICATION. SEAL AUDREY B. HUMPHREY r- MY COMMISSION # EE 061159 o= EXPIRES: March 6, 2015 oa$' Bonded Thru Nctary Public Underwriters Original Permit Fee $ x Open Inspections (%) = $ (% of Open Inspections). Example: [15 _ 23 = .65(%)] $175.00(permit fee) x .65(%) = $113.75 (Renewal Fee) SLCPDSD REV 4/11/2011 (Renewal Fee). • x 3G x ?;L FoII -up 4- / I-j bit uN >oo r 04/24/2007 - 12:26pm Kat FA03 Elements110 Loading111 CalculatorskASCE 7-021_FLB - ASCE 7-02 Pressure Charts F_ 2004 FLORIDA BUILDING CODE & ASCE 7-02 DESIGN LOADS FOR COMPONENTS AND CLADDING INTERIOR ZONE 4 PRESSURES Mean DESIGN PRESSURES (PSF) - Zone 4 Roof Tributary Area Ft 1 30 Height 10 15 20 25 �Sq 1 35 40 45 1 50 0 ft -46.3 -45.2 -44.4 -43.8 -43.3 -42.9 -42.5 42.2 -41.9 -15 +42.7 +41.6 +40.8 +40.2 +39.7 +39.2 +38.9 +38.5 +38.3 -47.0 -45.8 -45.0 -44.4 -43.9 -43.4 43.1 -42.7 42.4 16 ft +43.3 +42.2 +41.4 +40.7 +40.2 +39.8 +39.4 +39.1 +38.8 -48.2 47.0 46.2 -46.5 45.0 44.5 44.2 43.8 -43.5 18 ft +44.4 +43.2 +42.4 +41.7 +41.2 +40.8 +40.4 +40.1 +39.7 -49.2 -48.0 47.2 46.5 -46.0 -45.5 45.1 -44.8 -44.5 20 ft +45.4 +44.2 +43.3 +42.7 +42.1 +41.7 +41.3 +41.0 +40.6 -50.2 -49.0 48.1 -47.5 46.9 -46.5 46.1 45.7 45.4 22 ft +46.3 +45.1 +44.2 +43.6 +43.0 +42.5 +42.1 +41.8 +41.5 -51.2 49.9 49.0 48.4 -47.8 -47.3 46.9 -46.6 -46.2 24It +47.2 +45.9 +45.0 +44.4 +43.8 +43.3 1 +42.9 +42.6 1 +42.2 -52.0 -50.8 49.9 49.2 48.6 -48.1 -47.7 -47.3 -47.0 26 ft +48.0 +46.7 +45.8 +45.1 +44.5 +44.1 +43.6 +43.3 +42.9 -52.8 -51.6 -50.7 49.9 49.4 -48.9 -48.5 48.1 47.8 28 ft +48.7 +47.4 +46.5 +45.8 +45.2 +44.8 +44.3 +44.0 +43.6 -53.6 -52.3 -51.4 -50.7 -50.1 -49.6 -49.2 48.8 48.5 30ft +49.4 +48.1 +47.2 +46.5 +45.9 +45.4 +45.0 +44.6 +44.3 -54.4 -53.0 -52.1 -51.4 -50.8 -50.3 -49.8 49.5 49.1 32 ft +50.1 +48.8 +47.9 +47.1 +46.5 +46.0 +45.6 +45.2 +44.9 -5A 5 -52.8 -52.0 -51.4 -50.9 -50.5 -50.1 49.734 ft +50.8 +49.4 +48.5 +47.7 +47.1 +46.6 +46.2 +45.8 +45.4 -55.7 -54.4 -53.4 -52.7 -52.1 -51.5 -51.1 -50.7 -50.3 36 ft +51.4 +50.0 +49.1 +48.3 +47.7 +47.2 +46.7 +46.3 +46.0 -. -550 -54.0 -53.3 -52.6 -52.1 -51.7 -51.3 -50.9 38 ft +50.6 +49.6 +48.9 +48.2 +47.7 +47.3 +46.9 +46.5 -57.0 -55.6 -54.6 -53.8 -53.2 -52.7 -52.2 -51.8 -51.5 40 ft +52.5 +51.1 +50.2 +49.4 +48.8 +48.2 +47.8 +47.4 +47.0 -57.6 -56.2 -55.2 -54.4 -53.8 -53.2 -52.8 -52.4 -52.0 42 ft +53.1 +51.7 +50.7 +49.9 +49.3 +48.7 +48.3 +47.9 +47.5 -58.1 -56.7 -55.7 -54.9 -54.3 -53.8 -53.3 -52.9 -52.5 44 ft +53.6 +52.2 +51.2 +50.4 +49.8 +49.2 +48.8 +48.3 +48.0 46 ft -58.7 -57.2 -56.2 -55.5 -54.8 -54.3 -53.8 -53.4 -53.0 +64.1 +52.7 +51.7 +50.9 +50.2 +49.7 +49.2 +48.8 +48.4 -59.2 -57.8 -56.7 -55.9 -55.3 -54.8 -54.3 .53.9 -53.5 48 ft +54.6 +53.1 +52.1 +51.3 +50.7 +50.1 +49.7 +49.2 +48.9 -59.7 -58.3 -57.2 -56.4 -55.8 -55.2 -54.8 -54.3 -54.0 50 ft +55.0 +53.6 +52.6 +51.8 +51.1 +50.6 +50.1 +49.7 +49.3 -60.2 -58.7 -57.7 -56.9 -56.2 -55.7 -55.2 -64.8 -64.4 52 ft +55.5 +54.0 +53.0 +52.2 +51.5 +51.0 +50.5 +50.1 +49.7 -60.7 -59.2 -58.2 -57.4 -56.7 -56.1 -55.6 -55.2 -54.8 54 ft +55.9 +54.5 +53.4 +52.6 +52.0 +51.4 +50.9 +50.5 +50.1 -61.2 -59.7 -58.6 -57.8 -57.1 -56.6 -56.1 -55.6 -55.3 56 ft +56.4 +54.9 +53.8 +53.0 1 +52.3 1 +51.8 +51.3 +50.9 +50.5 -62.0 -60.5 -59.5 -58.6 -58.0 -57.4 -56.9 -56.5 -56.1 60 ft +57.2 1 +55.7 +54.6 +53.8 +53.1 +52.5 +52.0 +51.6 +51.2 I EXTERIOR ZONE 5 PRESSURES Mean DESIGN PRESSURES (PSF) - Zone 5 Roof Tributary Area S Ft 30 Height 10 15 20 1 25 35 40 45 1 50 0 ft '57.2 -55.0 -53.4 -52.1 -51.1 -50.2 -49.5 48.9 -48.3 -15 +42.7 +41.6 +40.8 +40.2 +39.7 +39.2 +38.9 +38.5 +38.3 -58.0 -55.7 -54.1 -52.8 -51.8 -50.9 -50.2 -49.5 -48.9 16 ft +43.3 +42.2 +41.4 +40.7 +40.2 +39.8 +39.4 +39.1 +38.8 -59.4 -57.1 -55.4 -54.2 -53.1 -52.2 -51.4 -50.8 -50.2 18 ft _ +44.4 +43.2 +42.4 +41.7 +41.2 +40.8 +40.4 +40.1 .7 .60.8 -58.4 -56.7 -55.4 -54.3 -53.4 -52.6 -5 9 c-51- -, p 20-ft_ _ ! 45.4 +44.2 +43.3 1 +42.7 +42.1 +41.7 +41.3 +41.0 +40: -62.0 -59.6 -57.8 -56.5 -55.4 -54.5 -53.7 -53.0 -52.3 22 ft +46.3 +45.1 +44.2 +43.6 +43.0 +42.5 +42.1 +41.8 +41.5 -63.2 -60.7 .58.9 -57.5 -56.4 -55.5 -54.7 -53.9 -53.3 24 ft +47.2 +45.9 +45.0 +44,4 +43.8 1 +43.3 1 +42.9 +42.6 +42.2 -64.2 -61.7 -59.9 -58.5 -57.4 -56.4 -55.6 -54.8 -54.2 26 ft +48.0 +46.7 +45.8 +45.1 +44.5 +44.1 +43.6 +43.3 +42.9 -65.2 -62.7 -60.8 -59.4 -58.3 -57.3 -56.5 -55.7 -55.0 28 ft +48.7 +47.4 +46.5 1 +45.8 +45.2 +44.8 +44.3 +44.0 +43.6 -66.2 .63.6 -61.7 .60.3 .59.1 .58.1 -57.3 .56.5 -55.8 30 ft +49.4 +48.1 +47.2 +46.5 +45.9 +45.4 +45.0 +44.6 +44.3 -67.1 -64.5 -62.6 -61.1 -59.9 -58.9 -58.1 -57.3 -56.6 32 ft +50.1 +48.8 +47.9 +47.1 +46.5 +46.0 +45.6 +45.2 +44.9 -68.0 -65.3 -63.4 -61.9 -60.7 -59.7 -58.8 -58.0 -57.3 34 ft +50.8 +49.4 +48.5 +47.7 +47.1 +46.6 +46.2 +45.8 +45.4 -68.8 -66.1 -64.2 .62.7 -61.4 -60.4 -59.5 -58.7 -58.0 36 ft +51.4 +50.0 +49.1 +48.3 +47.7 +47.2 +46.7 +46.3 +46.0 -69.6 -66.8 -64.9 -63.4 -62.1 -61.1 -60.2 -59.4 -58.7 38 ft +52.0 +50.6 +49.6 1 +48.9 +48.2 +47.7 +47.3 +46.9 +46.5 '70.3 -67.6 -65.6 -64.1 -62.8 -61.8 -60.9 -60.1 -59.3 40 ft +52.5 +51.1 +50.2 +49.4 +48.8 +48.2 +47.8 +47.4 +47.0 -71.0 -68.3 -66.3 -64.7 -63.5 -62.4 -61.5 -60.7 -59.9 42 ft +53.1 +51.7 +50.7 +49.9 +49.3 +48.7 +48.3 +47.9 +47.5 -71.7 -68.9 -66.9 -65.4 -64.1 -63.0 -62.1 -61.3 -60.5 44 ft +53.6 +52.2 +51.2 +50.4 +49.8 +49.2 +48.8 +48.3 +48.0 46 It -72.4 -69.6 -67.5 -66.0 -64.7 -63.6 -62.7 -61.8 -61.1 +54.1 +52.7 +51.7 +50.9 +50.2 +49.7 +49.2 +48.8 +48.4 -73.1 -70.2 -68.2 -66.6 -65.3 -64.2 -63.2 -62.4 -61.7 48 ft +54.6 +53.1 +52.1 +51.3 +50.7 +50.1 +49.7 +49.2 +48.9 -73.7 -70.8 -68.7 -67.1 -65.8 -64.7 -63.8 -62.9 -62.2 50 ft +55.0 +53.6 +52.6 +51.8 +51.1 +50.6 +50.1 +49.7 +49.3 '74.3 -71.4 -69.3 -67.7 -66.4 -65.3 -64.3 -63.6 -62.7 52 ft +55.5 +54.0 +53.0 +52.2 +51.5 1 +51.0 1 +50.5 +50.1 +49.7 -74.9 -72.0 -69.9 -68.2 -66.9 -65.8 -64.8 -64.0 -63.2 54 ft +55.9 +54.5 +53.4 +52.6 +52.0 +51.4 +50.9 +50.5 +50.1 '75.5 -72.5 -70.4 68.8 -67.4 -66.3 -65.3 -64.5 -63.7 56 ft +56.4 +54.9 +53.8 +53.0 +52.3 +51.8 +51.3 +50.9 +50.5 -76.6 -73.6 -71.4 69.8 -68.4 -67.3 -66.3 -65.4 -64.6 60 ft +67.2 +55.7 +54,6 +53.8 +53.1 +52.5 +52.0 +51.6 +51.2 WIND VELOCITY=140 MPH I MRH=O-60' ON Kd= EXPOSURE 'C' BS EETABLE NOT S5 FOR ALT Kd INSTRUCTIONS FOR TABLE USE: 1. TABLES ARE INTENDED TO DEPICT THE 'WORST CASE' PRESSURES. 'WORST CASE' IS DEFINED AS THE CRITICAL CONDITION OF ANY UNKNOWN VARIABLE AS DESCRIBED BELOW. USE OF CRITICAL CONDITIONS REQUIRED FOR USE WITH THESE TABLES. 2. FOR SITUATIONS THAT REQUIRE Kd=1.0, TABLE VALUES ARE UNDER -DESIGNED BY A FACTOR OF 1.18. VERIFY Kd REQUIREMENTS WITH LOCAL MUNICIPALITY PRIOR TO TABLE USE. 3. USE OF TABLES VALID ONLY FOR BUILDINGS LESS THAN 60' ROOF HEIGHT. 4. TABLES VALID FOR ALL ROOF SLOPES. REDUCTIONS FOR ROOF SLOPES LESS THAN 10' SHALL BE PERFORMED BY AN ENGINEER AS A SITE SPECIFIC CONDITION. 5. IDENTIFY THE BUILDING MEAN (AVERAGE) ROOF HEIGHT. IF THE MEAN ROOF HEIGHT CANNOT BE IDENTIFIED, USE THE PEAK ROOF HEIGHT. 6. ALWAYS ROUNDUP ROOF HEIGHTS TO NEXT TABLE VALUE OR TO A CONSERVATIVE ASSUMPTION. 7. CALCULATE THE TRIBUTARY AREA OF THE OPENING IN QUESTION (HEIGHT * WIDTH) OR THE SPAN LENGTH (HEIGHT) MULTIPLIED BY AN EFFECTIVE WIDTH THAT NEED NOT BE LESS THAN ONE-THIRD THE SPAN LENGTH (HEIGHT 2 / 3). USE THE AREA BETWEEN STRUCTURAL OPENINGS ONLY- THIS INCLUDES AREAS BETWEEN STRUCTURAL MULLS. IF THE TRIBUTARY AREA OF AN OPENING CANNOT BE IDENTIFIED, THE MOST CRITICAL (10 SQUARE FEET) SHALL BE USED. ALWAYS ROUND TRIBUTARY AREA DOWN TO THE LESSER TABLE VALUE. FOR LARGER TRIBUTARY AREAS THAN PUBLISHED, USE THE LARGEST PUBLISHED VALUE. 8. IDENTIFY THE ZONE OF THE OPENING AS INTERIOR (ZONE 4) OR EXTERIOR (ZONE 5) PER THE FIGURE OR INFORMATION BY OTHERS. ANY QUESTIONABLE OPENING IS TO BE CONSIDERED THE MORE CRITICAL (EXTERIOR) ZONE. 9. READ OFF POSITIVE AND NEGATIVE PRESSURES FOR USE AS REQUIRED BY THE LOCAL MUNICIPALITY IN ACCORDANCE WITH CODE. GENERAL NOTES: 1. THESE CHARTS ARE NOT VALID AS A SITE -SPECIFIC DRAWING. THESE TABLES ARE ONLY VALID WHEN SIGNED & RAISED SEALED BY FRANK L. BENNARDO, P.E. 2, THIS SPECIFICATION IS INTENDED TO ILLUSTRATE DESIGN WIND PRESSURES AS LISTED. USE OF THESE TABLES AND CORRESPONDING WIND VELOCITY, EXPOSURE, AND OTHER COEFFICIENTS LISTED HEREIN SHALL BE DICTATED AND VERIFIED BY THE GOVERNING BUILDING DEPARTMENT AND PERMIT HOLDER. NO WARRANTY FOR APPLICABILITY OF TABLE VALUE USE IS OFFERED HEREIN. 3. THIS SPECIFICATION IS NOT INTENDED TO OFFER ANY PRODUCT APPROVED CERTIFICATION. REFER TO ANY SEPARATELY SUBMITTED TEST CRITERIA AND OTHER APPROVALS FOR DESIGN & INSTALLATION INFORMATION AND APPLICABILITY OF THESE TABLE VALUES WHICH IS TO BE VERIFIED BY OTHERS IN ACCORDANCE WITH GOVERNING CODES. 4. DESIGN IS BASED ON THE 3 SECOND GUST (WIND VELOCITY) FOR A CATEGORY II (GENERAL RESIDENTIAL & COMMERCIAL CONSTRUCTION) USING AN IMPORTANCE FACTOR I=1.0. THESE TABLES NOT FOR USE WITH ESSENTIAL FACILITIES OR ASSEMBLY OCCUPANCIES. TOPOGRAPHIC FACTOR Kzt=1.0 FOR FLAT TERRAIN USE ONLY. THESE TABLES NOT VALID FOR HILLY TERRAIN. INTERNAL PRESSURE COEFFICIENT (GCpi=+/-0.18) ENCLOSED BUILDING ONLY, VERIFY USE OF Kd=0.85 (DIRECTIONALITY FACTOR) WITH LOCAL BUILDING DEPARTMENT. HVHZ = HIGH VELOCITY HURRICANE ZONE. TABLES ARE FOR WALLS AND VERTICAL SURFACES ONLY. S. ADHERE TO ALL LOCAL IMPACT PROTECTION SYSTEM ORDINANCES. 6. NO CERTIFICATION IS OFFERED FOR THE INTEGRITY OF THE HOST STRUCTURE. 7. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. a= 10% OF LEAST HORIZONTAL DIMENSION OR 40% OF MRH, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF LEAST HORIZONTAL PEAK ROOF DIMENSION OR 3FT (Im). USE ZONE 5 IF AT ALL IN QUESTION. CONSULT HEIGHT AN ENGINEER FOR A MORE SPECIFIC INTERPRETATION IF REQUIRED. EA a a ROOF MEAN HEIGHT ROOF O HEIGHT 51I ® 5 a® ® �' Op WALELFVATTON L ZONE FIGa ISOME TGUC URES to m > g REMARKS INITISSUE DRWN CL CHKD FLB DATE 04/19/06 2004 FLORIDA BUILDING CODE ENGINEERING x„ o� o� o m _ EXPRESS K m -H ASCE 7-02, MRH = 0 - 60 FT �To �r z - DESIGN LOADS FOR 160 SW 12th AVENUE, #106 � p ez -� COMPONENTS & CLADDING DEERFIELD BEACH FL 33442 T �� z m D (n C DO Zm THIS DOCUMENT IS THE PROPERTY OF FRANK REPRODUCEDINWHOLEORPARTWITIOITWRITTERCONSENTOFFRANKL L. BENNARDO, RE MO SHPLLNOT BE PH: (954) 354-0660 FAX: (954) 354-0443 z_m° o D Z AA BENNARDO, P.E.•- ALTERATIONS, ADDITIONS, TO THIS DOCUMENT ARE NOT PERMITTED HIGHLIGHTING, All INVALIDATE OR OTHER OUR CERTIFICATION MARKINGS . WWW.ENGEXP.COM M � m Ili lllllll II III II I IIIIIIII III II III < A FRANK L. BENNARDO, P.Ea9INC. INNOVATION W MI.I3A>.-;+ BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAAH DARE COUNTY, FLORIDA METRO -DARE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MiA1vI1; FLORIDA 33130-1563 (305) 375-2901 FAX (305)375 2908 NOTICE OF ACCEPTANCE (NOA) Rollingshield, Inc. 2500 NW 740' Ave Miami, FL 33122 SCOM This NOA is being issued under the applicable rules and regulations governing.the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County -Product Control Division and accepted by.the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below: The Miami -Dade County Product Control -Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,. the manufacturer will incur the expense of such testing. and the. AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Division that this -product or material fails.to meet the requirements of the applicable building code. This product is approved as described herein, .and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone. DESCRIPTION: ed-Aluminum-60m`m:Roll-Up-Shutter APPROVAL DOCUMENT: Drawing No. 02-534, titled "60mm Slat Roll -Up Shutters", prepared by Tilteco, Inc. dated 1 l/6/02, with last revision on 11/05/02, sheets 1 through 16 of 16 including 3A, 5A & 14A bearing the Miami Dade County Product Control Renewal stamp.with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE -IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the mam , icturees, name. or logo, city, state and the following statement: "Miami -Dade County Product Control Approved", unless otherwise nosed herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of thus product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA 'as an endorsement of any'.. product, for sales, advertising or and other purposes shall automatically. terminate this NOA. Failure to comply with any section of this NOA shall because for termination and removal of NOA. ADVERTISEMENT: The' NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this -entire NOA shall be provided to the user, by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This Association NOA renews NOA # 03-0123.11-and consists of this page 1, evidence page as well as approval document mentioned above. The submitted documentation was reviewed by C F.. Font; P.E. NOA No 04-0512.08 ation-Date:•June'7.,"200_ 9 Approval.Date: July 15, 2004 Page 1. RoIlingshield. Inc. NOTICE OF ACCEPTANCE: EVIDENCE PAGE A. DRAWING 1. Drawing No. 02-534, "60mm Slat Roll -Up Shutter", Sheets 1 through 16 including 3A, 5A & 14A of 16, prepared by Tilteco, Inc:, dated 11?05/02, with last revision on 11105/02, signed and sealed by W. A. Tillit Jr. PE, B. TEST 1. Test report on Uniform Static Air Pressure Test per PA 202, Large Missile Impact Test per PA 201 & Cyclic Wind Pressure Test per PA 203 of Series CD40, Aluminum Roll Up Shutters, prepared by Fenestration Testing Laboratory, Inc., Report No. 2606 dated 04/25/2000, signed and sealed by A. P. Gonzalez, PE. - Test report on Large Missile Impact Test per PA 201, of Aluminum Storm Bar, prepared by Fenestration Testing Laboratory, Inc., Report No. 2642, dated "07/25/2000, signed and sealed by A. P. Gonzalez, PE. 3. Test report on Simple Loading Test, of Aluminum Storm Bar, prepared by Fenestration Testing Laboratory, Inc., Report No 3013, dated 03/13/2001, 'signed and sealed by A. Acevedo,M. 4. Test report on Impact Test per ASTM D 256, Flexural Test -per ASTM D790 & Tensile Test_ per ASTM. D638 of plastic sample, Report No. CTL 0410G, dated 04/04&09/2001, signed and sealed by. R Patel PE. " C. CALCULATIONS 1, Comparative analysis for slats; storm bars, headers, tracks, mullions and anchors, using rational analysis dated 05101100, pages 1 through 172 of 172, prepared by Tilteco, Inc. signed and.sealed by W. A. Tillit, PE. 2. Comparative analysis of Storm Bars w/Spring Loaded System using rational analysis .pages .1 through 12 of 12, prepared by Tilteco, Inc, signed and sealed by W. A. Tillit, PE on 05/03i0I D. QUALITY ASSURANCE 1. Miami Dade Product Control Office. < E. MATERIAL CERTIFICATION 1. Tensile report of Tensile test per ASTM B 557 of Flat Reduced Section, prepared by ATC Associates, Inc., on 02/14/2000, signed and sealed by S.E. Black, PE. F. STATEMENTS. 1. Letter of Compliance issued by, Tilteco, Inc. on 68117/200.0, signed by W.- A Tillit, PE. 2. Letter of No financial Interest issued by Tilteco, Inc. on 08/14/00, signed by W. A. Tillit, PE. 3. Letters of Tel Compliance issued by. Fenestration Testing Laboratory, Inc., on 01/25/00 & 07/13/00, signed and, sealed by. A P. Gonzalez, PE. 4. Letter of Vest Clarification issued by Fenestration Testing Laboratory, Inc. on 04/10/2001, signed by R Zavala and signed and sealed by A. P. Gonzalez, -PE. 5. Assignment letter issued by Rolling Shield, Inc: on 08/20/2001, signed by J.A. Delgado from Rolling Shield, Inc. and F. Tonda from National Shutter Association, Inc. 6. Letter of Partial changes issued by Tilteco Inc.- on 05/28/03 signed and sealed by W. A. Tillit Jr. PE. . 7. Release letter issued by National Shutter Association, Inc on 09/15/03 and signed by J. _ A. Delgado. S. Conformance letter issued by Rollingshield Parts, Inc on 09/15/03 and signed by J. A. Delgado. 9. No change letter issued by Rollingshield on 05/10/04 and signed by S. Sanso: Candido F. Font, P. E. Senior Product Control Examiner NOA No 04-0512.08 Expiration Date: June 7, 2009 . Approval Date: July 15, 2004 E=1. 51 i0 1 137NS 7 • LHtn y17 vaDLO7 r r6•Wrl DLl'{OOa ! 3 LL7nl Y N3!' °N ONUIY80 'tiro ° 1p yro nywlne �,• xa SUDH00-03 ld - w • ®L-! f £S—d0 talrr VO,NLd O77Ybt11 rrJANYd oiwsswrsHiai 3RN3AV 41YL :H7d.00SZ CA 31M '0N1 '073/HSJNl770d► ''N 0 31' 1 LO/S/tl NM sr N-7LL1714S dO-77ON 1J7S wwp9 .Smnoo 3om-IWMW / ('Z'NMW) '3.9:j - �,�NFW , r -JIT AtM� � t>$81®D�ASRs'3EmB1`.rir' Ar c�rvU, aq6 u; rS;syC�'saaa➢gpurvlA 0191 g71n A➢BSIAa'd.tl:Sf�QiQB'�$ G3A%aMSJ.L:Jl oUd 30a0 3ALLY705D/MOY gtN07! ma iD HIOID •Z No= Mm AWIW 77WS Y/Yd mm (31- 3H Ta8 OM ttNr 1J]IYWd 3N1 Nad 9Yd 3NL d0 3rn azpM 3NL aW ZISMWdM (No, awon dq M05MdWd Mg 3N0038 7W MWA "'My DO 8[�x W m1<ifr/201 --V Y AD 03D14 W 3g TMIH SI.. d._W 305 (0) '03fd m it 0n01M armwoo 30 Ta WN=. T•MNddv 1:.YL00Nd ma (aJ %W7/HISNQfi37f SA(OtoMyo Na St 3M LY A[idq NOtL7Rt05xa7 20,U W SW W P3W,, SNplNAbO N 3a now aivm my mm 3lIS:/3H maatw�rD�l�� �'O�rd Sna NO t7lsYg 1atL0Wd 9W i0 AL31bS 351 10 ZI OM@rR..P7 NOIIYRVA9a OM' %VLMTd WOLLWW 3ha Nad 3®LSNOds7H 30 OL S771a14 (N 3LYNi0 sNOtllafNO 31M MIA 3mm •° 'I'll 31a N08d T ga7md 0tdra3dS Sag Y NOi N081'NNRIM'.30NINM lON loop N/Y A'KdAC7s A a swo 9M A9 Lr1M{V3Nd (4'Y•d) 1N7NR000 71/10i5fdr 1aRWNd.SBO hA 'L! �r xmwv MUM JAammom NY AB ml88Da 30 77YH51118 low" gNt .01aYd 10N IL46 vmm di-77W •IA N 'CWOWW 7OMW lOnMd AIRM mv-I1MN 74 Ox70 " '8Y7! HORS i0 rraupgif130170HId r 0135' TiVHs. dNYLg ' 7MJ 30I5 3N1 .dD .t1ViM6 adSOdCi 3HL NO WOYtd 3g T7YNS dNW .%&r#uHIS sw 7aLMH4 Y)I '3 A=IlY Nia9Nd.3MI5Nr 0{ 03NOr11Y 30 OL SI afilHlHs'3 3dYlL7Rt4S 3H1 i0 9S7NON!!OS D!L Ad57A Dt NaLaYMNaa 3HI i0 AIf�5NG67N .#L{ 3H 77a/3 L '0 !� teal A!!JWYJ 7Y8Rrd7d aBLO ®NOO 1 rsaY 3 NY1 lem FOUROZO my 1=dOYYi1Y 4h1iL°d 56'C g SNOLY,Mdla7d$ SNM077ad 3H1/M A7dAD0 TIYHS SNve /rWlb 370H1070N NaY m,e,c Q30vD7 ollla'ds 1V COS/I SN007H 3rQY1 11d 7t TJ<re MNaOXdIYl.o %) z)! r i/r C 1709Ikxad ILD%r • 32NWO 3=3 CNIOOWS '(1/91llN0 3NOrr) te35rp SL Xdt7H,01MN *uli9H3 aiN00pliN 3AODY 1W N0 t(7 �Yy'ON( + SY 39 T. SNONOxV OdtNflK7rr 3AOgV Nod ONlaYdS aNY 3aM140 3Cm M1N(Mrr 9N 7/NPCdtayi 11WOd Ag 07M -IWW R sV 3g al SMAWY N -X" 3' S170g LRMW r Y73Aga4d67N 91 i0 Ol v 9 'L '9 '9 SLiR{S N0 NflGLS R1pHa7S 3'18i0RddY NO mNf37d5 SY. 38 TMdS SMU23A'05T NOliM W SXd01�7 �q RA7ls Nad, ¢7Y171lW r2GNJNY (pJ i 3H1 -d0 mmrxP03ds OW SVDMXVWW 3N1 i0 77V MOM a37NNTRO58N. w 7NMZiLda'S ONOFH 3N0LTf11115 NMf 3HL H0Y.3N aEHI xa9,R3NOlS L9Q#YdMsWAM 1vHl .75v0 M (Z77 '�-- .:Y/! ! 3g 7MlS XNR NOON .il3NA\79 3NL a1N% '9IrlX9NY NOOdvl !O jfflAW A NRMN (I's g$ . NWLXII OM NO X70An8/'M77 A8 a3&WVinMR SY :rNOHONY NOOdYl I RTYM Num 3mmov wasp i O1 0; . 7rWd F17/LS fDVl/!D7 3i'R10lWlS NM13H1 xalga' 0! IZN10Ml Nf07 38TryxS SNGYNA1' ND T]YM OMl9Hr{ . Nv aN'r1Di 30 58i1Yd 89 Sl7NW 3L3gN9D Jb1a3Nd 7hOL. sa �,y (aY ;Y l 1 30 ju3t3�Mx1O�9 -nm t Sty N07dVO y�,dD4 � ltr tt • M'Wtmf om NO Kd0 Wh117 M 09&=V~ SY sNOHaYY Na74IVl I .Yr .am WOOMIS 3tsmwna7 7.w OoOr WN 31Mm' aa9n9d Lrmmv a!-h) (m10N 35MN3Ht0 SSaMIRJ 5110ROi Sr 30 7M6 N00O3NAtla X08 +9 871YN 3044 LUd 7TVM at S'dYN10Nv 'L A '90NadONM ABa7SRq-NOt103/LM 3NL N 2 3Lq XaNa io Lw drA rvx sins 3501L1 3r save Iranrs 1hoLMM;nVgpO mnvN,slvs 3p1I ,y .Lxit17 �rrt TIMW QiYIOM 38Y s/Y8 (LON Lq SNOaMN00 3NglNN1LH) 3NL ANY 0TTR1SNl ONV"¢gRV3N•3H:NV1 {7ya ON as ssia>,'3lvro3rrN 9xrAsvi LNM 3vrpa m9(LardsvaT r M ¢dNols 3e ayia�°sals,mmis 3}gYA0Ki9 's '03taiW/0 SY a7yRSSTO 3LY.'sNjg IBv1.r 77V SS3'OYJI , naa voA3NgmlY9! ti3dda 1aN 7 x saunas do T7a81vxt aNc•OA7n9AMR ang9m wig Spotli awMw 3pNMm N<N sNaapds ao 1081 a77lYtSNf 3g 1sRr1 Lx9e , ,s 4�a.K+NMa NH:'4b>tc+I �(e•�a vtid aaeusrm 3LON sHmrsna r xu9 3a17d 37sm v M t7gq 1N7M3 v Lnz� rNNs yrg l�pls Lum'xxvu 5lq NWa m ARM" AWN 37601tl/L7N 3g AM•SNOagMiSM pA71LN71011 0(106i0 t(p BDald 3W SN69:IWY015 9 + AC arw� N Mf 0 fW 9f pNDZ 'ffiIS ss7sm•1a 8'O a3W/A'IYl :w7rA,t'rnxx9rn il`YLOL'35 4L 81708 'r l 700xiB15 3f/SHI1 OB ONY yn0d ppµ,ryy 05/M S3-'N3S alr NO YOC 'Li7LS S63Wry1S 3g Ol S�A3N0S 77V r '(03MM 39Mpf3100 SS31Nn) A07ry 9e-1710D 38 71HI5' SNOlS71NUCl RnNNYIpN TIV i ' •MWdW srl WWI Yd UL sY HMN 1rLt 9rrt 'tYDs brat b18L [rot Rove 'east NaardLmt3p N3d SV 3000 mNatN7R 3rosY:'.BLL .,p Yt9o91 NONO3S i HrLM 30NY19'OlaY M O3tdH13l N33B 577t /M 301075;V 3!l71LYJ ONI'1.7YdN Nad.AOYT14iW$NLIIl1H5 dl-TION ®--/ Tta90Nva5 ➢B-L 30aY 30MQNOOCR'-Ur oA1t `4'd�° 8Y1.'a0 O.iid3'0MM 0Le18 Y Nad Claw mi."3108Y A . 0d91 Na WMY iCfiB by 03Nl/Rl3I30 38',TTOW :SW7'WM."W320 1r07 .r•-� &W 03WWA N33s�9YH' ('Ord) � 30 TeAO&W 1WaWwr'No to nnwl aT ' sxdlr'm an-770tl 1 7 ° �: = = --.'= Y1"_ ., • Ili-- _ _ _-= u{� �1II i/ mail®�II��'1' ram; _ I i d 6a @ �C O No O N II N n. 1 If Z-M A 4do (37navw 335) OWWS AOf71M '+°R d ! -�' RVdS tl30YiH Q " ' ! `JNLDYdS NO(I7nR 'ropy i :iMflYiDKdYlOpl S!N'7NOFlrr00 aai 9L io r v Z 133Ns 33S mom Ogn 3N SNYN /1m NWlYA373 1-W 3ldiL7fM TYJfdt! �3ruuvr3�rran.strtavodrrno lad a1 d9 n ra-t�dNs s aton . i ®3Ni'SNY& ANQtSr NIOdLYA373 :INQ.•37DNOS7Y�Id nQdffla 33S) d6 J ND) xopy �-�•(371703i1.7S 33Si NvdS 1VIS •x°ry-�{ A NJS 335 NYds 1r/S 'mR (3AMa3NOS MS) NWS M30V3J1 v / v /'. (O113 '02 •dW �OOv ('14 ©O d d fik I - / A41 .'In_���I��a� i d r c �ao6D �za6D•—.{ © TYPE 2 SLAT: r EXTRUDED ALUM/NUM BOTTOM SLAT ' MM-76'ALUMWLIM ALLOY SCALE.• 1/2"— 1'.r 16B' r Ie&• w / N © TYPE 1 STORM BAR-' 2" EXTRUDED STORM BAR 6061=75 ALiAlMy ALLOY SCALE 1/2" - I r / �aCba �i--zoao•� ® TYPE 5 STORM BAR. - EXTRUDED STORM BAR' © TYPE 6 STORM BAR: ' 606346 ALUMINUM ALLOY r 4" HEAVY 'EXTRUDED STORM BAR SCALE. 1/2' 1' 606J-T6 AL(lNWU." ALLOY ✓ SCALE,• 1/2' = 1' i / r 2966' + 26I0 ER66' Aai• 1.601' �•.� .IfO' 300 .IBJ' Y Ate' L� 3 _ .J60' ,� r 21r, TYPE 1 © .TYPE Z ' © TYPE 3 SIDE RAIL: SIDE RAILS: SIDE RAIL: 6063-T6 Alum. ALLOY + 6063-76. MM'ALLOY . :60BJ-T6 AU . ALLAY r SCALE.• 1/2• a 1' SCALE 1/2' — 1SCALE 1/2• = 1" 1 ate• .123• 4� / Q TYPE 2 STORM BAR: 3" EXTRUDED STORM BAR 6063--TB ALUMNUM ALLOY r SCALE 1/2" - I - r 7 r 5000' 426• ' / © HEADER TYPE I.-' 6061-76 AUAWUM ALLAY SCALE. 1/2' = 1' ' a625' 267' 422' AGE' TYPE 4 ' SWE RAIL: 8WJ-76 Aklm. ALLOY r SCALE EO TYPE 3 STORM BAR: (b TYPE- 4 STORM BAR: ' 4" EXTRUDED STORM BAR 4" HEAVY EXTRUDED STORM BAR 6063-76 ALUMINUM ALLOY ✓ 6063=716 ALUMINUM ALLOY r SCALE 1/2' - 1' SCALE 1/2' - 1' OH HEADER TYPE 2: ' SOW-75 ALUMMU ALLOY SCALE' 1/2' = '1' r oLa^ N 01 HEADER TYPE 3. r 6061-T6 ALUMNUM ALLOY SCALE' 1/2" - 1" ' ' i> ^:1"; 'aMniV;Vpr�y L';.i;Cufti 'L3FiF/Y8® 47C i'tn66N Co0het i^%�:;:i 3�x�t3,�,;ct H:u.lvol F.B.C. (H.V.H.Z.) / WAII—DAD£ COUM 50mm SLAT ROLL —UP SHUTTER As MOWN scALL' ROLLINGSHIELD, f 1�2 INC. PAN �wO�COMMMY 2N.W. 74U AYENUF , Uan-Qi�.ul mr6e 4 RA70A J3122 02-534 a t r ,tsmv urf ✓n: x, mesmv ra DRAWINO N. fill SHa7 2 or 16 J ' _F J Q J ' .y40. 125• .125' T1P.' 1 1 J OO TYPE 2 MULUOK: �J TYPE '1 MULLION: ' 5" EXTRUDED MULLION 4" EXTRUDED MULLION 6067-78 ALUMINUM ALLOY WSJ-76 ALIAMUM AILDr v SGALE 1/2• - f • . SrAM 1/2- - 1' - © TYPE 3 MULLION: Y _ ' 6" EXTRUDED MULLION 8063-75 ALOMNUm ALLOY r Sr.ILE: 112' 1° J Ip 7r.nniler RENEWED it�• n f / -02NoD4.pg 2Ak m '� ys�aea I a J , Mar 4s cluu UB DETAIL dne0l o INtluf:i I (N. r. SJ h - y�i 4I Division J a J & . d t/L' Pit7371L'd f:.."r,'Niu&:Se 7DP'PRDALE 300E-H2B ALLOY. � 45' LYJAYtER . trW J t !/,r �8DR0N LFMER W/F4USIL (0P0dY41.1 � .. REAR FROI E JWS2H28 ALL �Pa � L#OI7DM PROFRE JOA4•-N28 ALLOY. . • =V? PROME M054H28 ALLOY. . 7 u NYLON DISH, 4 1/4' a D. ROLLING LVSHION W/BALLS BOX SIDE BRACNED casr ALllMlNUN.'t.d:^�tu��'rnt8 ® BOX SIDE BRACKET TYPES B wBBGne r7/32• Wme l ® a SIDE RAIL. _ u GL�o Jttr. D F.B.C. (H.�H.Z) / MIAMI-DADE COUMY a (OPDOHAL) 11 EXTRUDED ALUMINUM ORAFfp4'0 HOOP. - 24LYAAuzm s7EELrDRuN: 1 9/1B• a LL , aam- 7hk. 60MM SLAT ROLL —UP SHUTTER As S01 N . RETAINING NEIAL PU7E 26 G0, Got,. StL'Ar:EACH am, ' WAX ' NYLON REWULE• 1 17/32' 0. a .r a045' 7hk r '` ON FUM ' �'L 'EC O �Nc. ROLUNGSHIELD, INC. CAIE �Q BOX COMPONENTS AND ASSEMBLY DETAIL SLR 4 ":�• x S. nwr n3nn a ENae mvHa cDirPAntr 2500 N.W. 74fh AVENUE race Jrx 4en, s.me m - n mrn LBANL fLOR/M JJ122 02-5.T4 (SEE 51tFEr SA OF /6.fOR•AL7FAM61TE ROIL-L1P S1HllIFR LlFL1NG ALEI`JNNLSYLS y1•t�R-7-'�-v��n�- n.w a (.m>1nr�rtmI+B p, -.iaa, eK r mroa dx ' Uwry YI n➢ GUUJ YMLTEII A DRAM7NB No nuff d'_ R E �d'Jr eaarnw da - RIORfaI IlG 4f1E7 °�0°-1� ,r ' TYPE DRIVE ROLLUpSHUTTER SYSTEM MOTORIZED ROLL -UP SHUTTER SYSTEM. -I HAND CRANK ROLL -UP . SHUTTER SYSTEM ALTERNATE ROLL-im .SHUTTER LIFTING MECHANISMS P?-;!?rp"T, RENEWED S1E7?SDUe^.SF. [: J'i.^•.h) d4-ir:aCcal. i:.c;;c[2'i:..' quo 09 7BSvk�O ee6CDGt1o9 ai,�'�c3seC�.exrrl F.B.C. (H.VH.Zj /_MIAMhOADE COUNTY 60mm SLAT ROLL —UP SHUTTER '`s sORN =lull ROLLINGSHIELD, INC. 2rO N.W7�1h A96US f2111u YJW RDRW M122 02-534 706719 r dr r nv+ �s r mmm,. ,ra DRAWING No 'Ll Jr., R E r mc:m-na rriam , HiR7 _ _ _ SRtET 11 W 1£ POURED CaWMW OR ,/ CP11L'RETE liCP0.Y 250• Nxr. ,- . . !� a4 � fE. PN RE'P111F6�D TAv / T REtiUfIdED AANCHAW a Scmuw ON (SEE� O➢S SN ON . A� A N OO- ' / • OR O O © OR 7V lf4 x 3/t' S ,U, s. O R' 0. P.' ' 11311/8; 21311/6; 3131///d• OR 31t1f/g• a ht r l • S AL S. / .500• .600• CIA'(. ANlD-OUT Tf18En , O• A C. PalmnElE LAX RWM ! Yr 2•r 2nL o TwcliaAilie1°n�. ' A ! A O K , OR A" SECTON P• - P (1) : WALL MOUNT i 1/2' = f • SECTION P - P . (2) : MOUNT S/DE WALL / SCALE f/2" _ f', o©DR® 3P SIDE RA/L ANGNOR S/YJt J SECTION P — P (3) : 9UfLD—DUT MOUNT W-1 ,OR W-2 MAX/MUM ULE SQ".'. f12•=,•, DESIGN PREs511PIr C je AND 'SECTION R — R : NULL/ON MOUNT ' G (FACE MOUNT) . L i7 SCALE f/2' = f" . (USE NEGATIVE PRESSURE VALUES AS PER ASCE 7-98) MAXIMUM - DEVr.V SIDE RAIL JO SIDE RAIL ©- S LOAD .V, (P:s•L), WALL MUNr Bb�M Ma i1roUNJ W�- MOl1M WALE. MIX/ 6 4' B' ' 6' - 4112.. MWM . BO OR LE55 _ 6'.6'• g• g 6 B' . 6' 6- >80 7D 150 3 1/2% 2 1/2' 5' _ 3 1/2•_ . 3.. 6-- 3 //2•, >!50 7D 225 2 1/2'- - .. 4'_ 2 1/2', 2 1/2'. 5'. 2 f/2" . 6• 5 1/2' l 6', 6' - 6- lDE RAIL© SIDE' RAIL © - M N6WE 6U1L0-OUTr4- INSIDE BLIND-PUf MOUNT • MOUM .MOUM ' MOtlM . 4" 6"4 1/2". 6. g• , 6'-6" , 6• 2 1/2.- 4'-J. 6' 6' 6. 6• MAXIMUM ANCHOR SPA IN (/p) AT SIDE ' — ffAILS VERSUS D-D1SiAA1C_ a E.. D. ' + MAXIMUM ANCHOR SPACING ARE VALID FOR i Y'r 2'r .1 3' 1/2' EDGE DISTANCE FOR E D. LESS 7MN 3 .112- ArAMRIN AN REDUCE ANCHOR SPACING BY MUL7IPLYTNC SPACING SHOWN ON SCHEDULE By THE FMLON7NG FACTORS' ' (REDUCED SPACING OBTAINED USING FACTORS'SHALL' NOT BE LESS THAN 37, AC7UAL E. D. FACTOR _ .. 3• f.75 21/2•'2- MASONRY ' POURED CONCRETE - —y/y I O r SUBSTRATE LEGEND OR J14 x 1 • S O 6' O. C. PRODUCTRCNFWHD as "Plying r4th the Florida A ' thh6m3 c.de T ee,•P�.� c: No 2 . lay. --W Dade Product Cont al •Lax. 414 314's• A/, : : Dlvlcbu ©OR ® - W-1�OR W-2 A SEC710M Q — q : MULLION MOUNT ' aS• L (FACE MOUNT) aL' 2' r Y x . f25' Cant tPRSi.DUCi' Fdii^✓9!iR3 SCALE 1/2' AUMNULI ANPIE Aa3 xmaa;A•tF.�;i y. 114 x r• s rI s ✓�errn•a� -«',: ..0.�-. 1.3,11 MOM R R : MULLION MOUNT (IN57DE MOUNT) f/z' - 1 • DlvleleuF F.S.C. (H.V.HZ.) / ML4MI-DADS k MAXIMUM ANCHOR SPA IN (/p) AT SIDE ' — ffAILS VERSUS D-D1SiAA1C_ a E.. D. ' + MAXIMUM ANCHOR SPACING ARE VALID FOR i Y'r 2'r .1 3' 1/2' EDGE DISTANCE FOR E D. LESS 7MN 3 .112- ArAMRIN AN REDUCE ANCHOR SPACING BY MUL7IPLYTNC SPACING SHOWN ON SCHEDULE By THE FMLON7NG FACTORS' ' (REDUCED SPACING OBTAINED USING FACTORS'SHALL' NOT BE LESS THAN 37, AC7UAL E. D. FACTOR _ .. 3• f.75 21/2•'2- MASONRY ' POURED CONCRETE - —y/y I O r SUBSTRATE LEGEND OR J14 x 1 • S O 6' O. C. PRODUCTRCNFWHD as "Plying r4th the Florida A ' thh6m3 c.de T ee,•P�.� c: No 2 . lay. --W Dade Product Cont al •Lax. 414 314's• A/, : : Dlvlcbu ©OR ® - W-1�OR W-2 A SEC710M Q — q : MULLION MOUNT ' aS• L (FACE MOUNT) aL' 2' r Y x . f25' Cant tPRSi.DUCi' Fdii^✓9!iR3 SCALE 1/2' AUMNULI ANPIE Aa3 xmaa;A•tF.�;i y. 114 x r• s rI s ✓�errn•a� -«',: ..0.�-. 1.3,11 MOM R R : MULLION MOUNT (IN57DE MOUNT) f/z' - 1 • DlvleleuF F.S.C. (H.V.HZ.) / ML4MI-DADS k �> GDVcl�7E J 1.000' I'r T' 7aJ' Gant A&M AWE � � j W/ CaYCJ1t7E Mritag O 6' 4 a -�I .,,s��g4gq,,,���ees I" i" f/2' x .12b' r + 7 0 0-4�• AL M/" •C Um I'r a'r .126' rbnt AMn ANON ' / � W/. taYLRE7E AHL1fOR5 O' M' a a -y.7s0'»f�•.75A' 1 r/.�' x f r/�• x `' 'PoR Oi6TAwnox rMD WNCRpE •' 12 x b' STa% BAR USF (27 1I4'/ TAPGNN ANCHORS ANCLE . dE E6n S,Vum. EA Sl FOR OESICNLa1D5 UP TO 69' S7AT SAW d I I ANOLE WI (2l J_/B' r J' POWERS + SK ( EACH 0 ,m + r5. i ��` `' I- 86' MAX. STORM' MR SPAN s d f2) •oxJ° powm 80 >S SftlE F11 'GREATER + o 0 II O 0 - RL>nrtRFO i \\ LIA 03,Wp SPAN CLWDIDCNS NSFAUA)tONS INro HEADERS \ ! 1 2• I FA SIDE " O O O ' ' o C Q O OE O m J/4' s M, S r ( SUE: / I zDA,. I.o 0 SECTION S — S (FOR F/XED STORM BAR) r II (101.). I II I II r 8 I I r SCALE: J/2' _ ]' �f ((2JJ 19 r J 4' S M S. WALL � ESL �DE � n I J 'J II I 0 I G ,QH oR Ol I�zoao I ° ( ) • I I I I O O +FOR G OH DR O r 1 7 60• aREM �/2 r USE (2) 114EON/8� INMr� + ia#• x X f f ,avr FA. SDE MR DEi'IG•A' cabs UP m + AUW Nmn. AAMC 80 PSF.• 5{' YAK SLiT SPAN & SECTION Si — S1 ' SCALE : 1/4' = 1 • •+ EXfSRNO�I I O O II I I I I FA sw 06' M4C 51DRM 81R SPM; d (P) OXf • * . 1/4' m-20 C1ASS II ) i + 1 I 1 I C O Th7F//RR4' C"-WS FA, SUE Fb DMAND ' OR ,J o 16 MACH/Nf " �B U3/B•J% Y%f'IL4? II I I E>rct7Lv0 �I� + GrttCS iI I I I E FEusE O O MSTA[IAIIaVs(WR! HEIOlRs(C�. ® 2) /14xJ/{• Sys N ' ANCHORS >YESPECTNELY SILALL BE LEFT TOGETHER W/ gHCHORS ' I II I I II I .. Q O • �I, I I. I I i I &jo G AT THE TIME S10RM BARS` ARF REMOVID., (SEE OFT. A). + � O@+ ce 0 I I I OE OF SrmFT 12 to j I 1 I 1 A O' . " MACHINE SCREW FULLY II I I• I I I I I + 1 I I I - %J7 W1Nc Nam+ ' ' ° ENBODED 1M ANCHOR II SM27 12 of rag' I I i A° I I I i i 1 J OK SECTION S— S (FOR ° ANCHOR + REMOVABLE STORM BAR) 1 SME: 1/z- = r r DETAIL A ANCHOR & ANCLE SCHEDULE FOR ELoIA77ON DMW LOM (Po ANCHOR rypE d atamw AAGlE n6CKNECS 720 OR LOS TAPOOR•' . Ile 160 OR LOS ('+) W8' 0 x 2 1/4' 1/4• : FOWERS 80115 SCALE r 1/2" = 1" r C O O O STOR &R (O1EJ2p57/'HX /� FA SNE E1. T-1:Y 5 II I11 1 W/ 4 -0 Maa: Sr AT II I I E SPAN J' 8'-0• MAIL EMU MR SPAN T� r T X 6 M_ Cant Akna ANOLF ¢HEDM[E MR T1OCrQhSS) i I II + I I I I C I I I • I E F I 7 i i �\`\ abno• II i. i � 0 s1 ' I I. j _ A J ann• aao• baa• zom- , 1z Z • C I U I;I AN OR s I .1 I %S IV e0trs ELEVAT/DNr� II I I I 1 0 10 O 1 1 1 Z' r m 4• a c. Rr3r' o rz•.+ O O 1 (SEE SClrlIDlBE FbR OWN777Y) r O O I i0 O 1 / I I SCALE : 1/8' - 1' , 10 B, I S 1 n I I • ' 1 J I i I Fi:r4S!C.^s A5•••1r;1Jl;q P&IO➢UC1'lCEY1SED 9 1\ O O� \ I vs;a,� :;r.•:Cp .Ail: eke GYO,iila tm emeP?YinJ erSeQl eha 6+Ind..b I 2'kTi•260' O»R T1TE I SRWdr MltJ, �tl:±.(,L•;; U:.:: iR�.".'rz L`:�'.; . POURED CONCRE'!F ` 2 Sk�E50• (FOR TYPf 7 STORN SAR) OR rt6»:yQEract No .0 12.Q4 .�sE,su^...::.. ;0,�-, L j j I S1gNM MRS r e.... •.„.. ." .. (FrX+ 1rPE J A a y ) ••+3Q+A68Vd09®AEA;.a.....,. ' 8 r�OIORFD • A&a FOR TAPCpV AN(4MRS ' ( I , `� O D AAXn� ANr2E E+1. SIRE X 8' I J/e'A+a 1/a' A7NFR5 OIL'SS10 WWILL AT •7 4 • FM CAIX-/r/ ANGIQR$ ANAE '•• C12 AOMEIPS 501.15 ANGIO,RS X 004* C6MFR OF ANrBE LEO ! craw 8AR + 19 /r4 T/+ ro MIa�ilDa�ePrbdictd ourydTarnE ➢`c,, rra; xsi ri R 4 a �D/y' r p DwC&T, r 0 4 a s as CEILING rollrRsBaL0.AY 2 r dP.TIOIVAL r + STORM LL�R GOaNF[+TIOI� FLOOR MOUNTING /NSTALLAIION W/ FIXED OR S '---` I ° 1z• o. a (SEE' F.B.C. (H-VH.Z,) / UMMI-DAD£ COUNTY T REMOVABLE S1i7RM BARS W/CONCRETE ANCHORS WALL MOUNTING 1NSTALIA7JON 60mm SLAT ROLL —UP SHUTTER W/FIXED (&W SWdA1 I AwnM rrsF n i STORM BARS W/CONCRETE<ANCHORS /SrA+£ : r/a• r scow - SO". 1/4' f • + 11/s/Oz I:L. 'E. Q �N�.. ROLLINGSHIELD, INC. DATE SdV iE SPAN sEcndvs AhD DEuzs ' SECT/OHS V — V ARE9INAR ra ADD4E sNnIIN W1nAAR . 57aPM 61R d NrlpptS IRLI' 1F»i1N0 d' 2500 N.W, 741h AKNL E s, NI!X ati NMO WINMuw FttwaA .xr122 02-534 /nm. f+�/�- _ 0 200 0Ltl'B71 .Vr rfY M IQ/IxN X1il X11: ri y;, ORAINN6 NO WAL7FR A ac nt ne rwFm far67E X - - - - SHEET 5 or 18 r / t•x Yr.tE7'ConE Ahxn ANfxE + •C1HT�R7E CGAIpREIE AAIOlARS 0 8' 6 4 • / j t' x T' r. ITS' CML Alves Ay= / i r x71 xr ' W/ CO/lCRETEANChYIRS ® M' O.• G '� r2N STORN 84t 1 +II 75t1�{I-- 75D' �DE m. ANGLE + 1 I fUR (Wy)SfA1l�l�A710M WTO CDNOREIF, r 80 PSF• 54' r� •75a��YeO' Eft SIDE f0,4'DESI�GN LOADS + AlIX..¢AT SPAN R BB' ' 11/T•r.1 ITT x.fT5•x- 0'-41/2' ALUMWUM ANGLE . BWW.T(25J p3 •� 3' POWERS Q �r - FIOILRFD Op111dElE rrr ���� "t1__.Cv1 _ II OOb REOL�u � I r. �1 2- MAX. SR1RM BAR $PAN,,3 (Pj - O O. 3/8'IXJ''PD{fDf9�90L7S EACH l SIDE FOR GREETER :DESIGN LOA0.S AND + r II' H t ERS-# � CWSIAllAT10N NIO (5) jM314• SMS EA SIDE. D1 OR F] Ai Q V SIDE, 3/4' S. AA 5. r / o 0 0 SECTION 'S - S (FOR FIXED STORM BAR) Ir'•-zaoo• I o I II (lYn.) I a SCALE : t/2' e 1 • . t - WALL ss Ea. SIDE n 5D 7rT5' x x5T7ue1BAir r SECTION St - St ' D Q OR Q , I �" nEPTH Arum. ANGLE r SCALE: 1/4' - f .600 OR O u') I I I I r / I FA. SIDE - FOR WSTALUTWN INTO CONCRETE ' ' Ek7M it I S r'^V^ _ ra- smwwmIXASS cussUI I `,^�I w DIA^S•&E SfPAR4NN/ TO!] I 1 I I I USE l27 7/4•�X7/B`lSILK-W ANCHORS EA SR7E FOR OESIl1N LOADS + UP TO 80 ME. 54' NAX. SLAT SPAN & 96• WX STORM BAR SPAN, A, + SIVE 3tORX! TIER .DMON LOADSAND " J L15E (3) (74X3/4• sMs' SIDE e- Sf fir If ON SHMTr II I' .. I �J I I l2wis' a I. I j I I A f to 72 of to II I I 11 a - I I 7%B•TIN 3 2 WWD NUT! Q OR F1 / OR F1 r SI ' I i A ° i i. I J OK SECTION S - S (FOR REMOVABLE STORM BAA) r • II I I J K O © OR M SCALE. 1/2° - 1°+ 1 1 x J i z' . r p r I OR �Y1 a I I 1 O O x' (BEYOND) * 1/4' d-20.OR 3/B" d-16 MACNIN£' -O� Ai W SCREWS USED JOIMLY W/ 1/4' I x + I�— I I ,I I�•-2,000' I I II I 7/6�_ OR 3/B° I x 1 f/4' CALL{-1N ' E'A, DOE FA tEG s LA s I I II I II I I I I 1 I I I I (BEYDAm) a (18i•J I I I I a I I I I u I I I OR5 rTESPECTNELY SHALL BE LEI.7 '-.. TOGETMERW /ANCHORS AT RIE RME Q 2• x a• Mm•. mnn Awm, ANc:L• STORM $ARS ARE R11fDVE0. (SEE DEE 1 I ° A i i i i D ORO I a , I I I I I I AG1CH/ME SCREW II I I I I 0 OR Fl . ... IfI . I I e• FULLY EMBEDDED aaa• ooa• 1zao0• •. ° . INTO ANCHOR tp 20D0° 000• 00a' 00a• Z00a- . . . I "") I I I a I I _ ANCHOR TMCON ANCHORS OR e'a a n ,. J 8' • x T 1' 4' PDWf I.,.L1S � •SCN 'I o i i. i nu R o12iA1arTr» A• DETAIL A ELEVATION Q / aII I I t SCALE: f/2' - 1 • , SCALE/ 1 • , II 10001 00� a �0IPOO I S' 000 Rmtmw - AOaO• tTua AIR LY�N Mp/0!S • OROtt1t�41 AN '2 T'r S• r 1 . •. OR ltavtRs eaL1s �Ra,,uesnw-xxE w� PDUAED [ E•1E•--� a' ® '4 G OR ,TM7.R r.T t,4- r OR ODROPE7E•8fO0Y POO Sam At M 6AR raw CEILING & FLOOR MOUNTING /NSTALLA110N W/ fLYED OR Tr4s a REMOVABLE. ATOM 'BARS W/CONCRETE ANCHORS- - W' MOUN17NO INSTALLATION' W/FIXED , I sm swww v Fw mom nw STORM BARS W/CONCRETE•ANCHORS , �wxE s A� SECTIONS V — V - c - ARE snaAR m ABDYE sfIDMN IwRIDUr smut Bw • r�7s — ANCHOR .k ANGLE SCHEDULE MR aWAnDA DESIGN Law (prl). ANCLfOA E :4 MO OR LESS a (S) 1/4°RS d TAPCQ MS OR LESS (8) 3/8• 0 if 2 r/4' POWERS BOLLS . xz i RENEWED ^r:;x�lahOsaWa7ldi PRODucrmISED nca—Flyhm d9hartsulord26 r:,'.•.::�aa Pla. P..•7;W?f: i6 vision }�la�:; 4?n:r� 7'�ca'ow:t �':v�4as.9 Ltsa:•4e t ^"W/ 4=0' Mm, MAT SPAN"h B'-D- AUX, SMW BAR SPAN r RQN,• E F.B.C. (H.V.H.Z) / MIAMI-DADE COI --)2fi'Cent AAnjAM2r NEFF ANOYIW v a a' W/ CaWAEW,w 7NRS a 12• a a f PLASM ji . . . In, TOP G OOR O ISmw TIP sFPARAnaIr To av -war 1.2 w le @ OR@ SW cm S Shw F2 or le S II I S III (D OR X-j A 2,060' c @ II I II R O 's Bmm J. BOTM • a S)srEw OR AI 11 PLASM MEW-) r1F1 B CEILING )OR UOMNG 4 POURED ORCpY#7E at= fiMMED SECTIONS v — v SWIM ✓ OR@ SYSIEV O ON UF SECTION S — s SECTION s s : DOUBLE STORM BAR SINGLE STORM W =LF: 112'- 1, SCUE.- i121 E o,, AS AFFV04aLE ^A pE SC11DUIE FOR IHMIES) 4 1A - ow" 4,00.zoo, 2.0m IA;P.N,WHORI 0 4' REST a 72' (SEE(,lbOLE FOR QU4=TY) ELEVATION x ANCHOR & ANGLE SCHEDULE FOR ELEVg77ON X DESIGN MW (pt) ANCfOR ME & QLWMTY AAfCX THICKNESS SAW U BAR 7WE 7a0 OR Los Fr,) 114 - 0 WCOMS 1(�)@@o DOI CF)l ✓ W1 4 , -0• A�.. StA71 spAm & s• o- uAx swRy 84R SpAN 'EWE" r"crsx.g. l'RmO!T'iCfTnJM". IN Fluld. • Avfqi4 I'm KT,s -OF-j2-j2 , F.B.C. (H.VHZ.) / WWI —WE COUNTYi 60mm SLAT ROLL —Op SHUTTER AS MOWN I scar J' x Y (1tm:) '17B' CxrlG Ahxu 7DBE + 1� r r r .125 oxlt. / + Y f7s• 0'aM Ahan.' w//7'+7'Y .IPJ' x D'�7• (Ym•,1 fe a ra W Y r 4 f'Y 2• x .f26' cant Ahura, ANIXE W/ ALABNlA/ AME m emeD-.aur 7fIBE• 1 s x �/r• sus tr rr a G ro D,9E w/ r: P`x . i7s• x a-C (Ipa J 4; r J/4' SN 4 FA' lEO +� ALfAOATst ANaE m Bi16D-EXIT m8E 114 r J/4• sACs a it a a m ]UDE, ✓ . f= ftl•'GRf m o I Q J i* r .7/4' s1Lt EA. !EG nL _ J. �✓ fUl1. L&Vdfff m PoD1s'D 17•,a G ' FOR INSTAW AIR /��U Els �� S. NSE W AAA POWFD f / 1 0 O BD.D @ (J i4x JaWSuTD+ mN Lf rORFA7ER 000' C OOorO . + ✓ O O O \ (21if4r3/4'S ALSFDR✓ . jI + Q g + oEE55i(OJ Lcmn Gw ro eaa pa.t ✓ . /2 FOR N L OREIIER THAN !1 x x ®tRr/ 8a0 P.af. FALW SIDE ✓ I FA' S1�f JIM ANC SECTION S3 — S3 I O'_ © I I I {7 - ' . I 000 ., I j+75a• .750'•j I I ;795 370R6 61R DEPTH t000" ADn, I � I + i O_ O O Hum. ANGLE - L E1. SIDE I 2000• Lft / n / , ' v KVMW Gass Gum Q I I + E F1T D1 orQ 1 I SH S LE EET I7 7L + F17R DE'S(LW Ln40 ' �T•E7 A7lo/J A + I +' I I N5TN1A NS Rfm �1/HE' A @HEADERS C (Af OR(!1 USE J I1P m BDO paf. J) J /4 DfSIGHI. GRFA7�p . I I _ .. FDR A6>t. SEPAIBI7IGV—�-y I sZ1bEIFDa Laws uPalg THAN 6aD psG FACT! srDEr' J O©Of®(�7Wm) sao pst @ 13 x 3/4• S N. S EA. Sf0 EbR R4ATER ..� O©or MOftWND) DESIGN LOADS - .. SECTION S3 — S3 - + I' I r r - C Do E FOor . 7.OD0' AGi C D O er aawo• Nha. I I I I r.7• a x. x 7$ cam. ALDAO-AHSIE (°1) . .. 1 - I I I, I ® I I I - 43 /8'I X 2 !/ 4• PD#M Bars aG AT TIRE' (, P• J tr 4 SRW BAR D or F1 ;m. Arrucaef£ ' 7usE I I TwmD ( D) I I A ✓ 6 @ 6 5 OLRY L C17 E�1 SfiRN 8AR OEFRf Alum. ANIXE W/1?� I 14 Y J 4' S IA I + I E F F1 UA 7 LEG tr&WON LaAas R GREATER DEiIGN LDADS I � ✓ 000 go 1� -O O O B V ,zoDo 12000' --R 00•-• DDD•' tioDa• baD•-•:-,taoD• t2Dm• ftbaD• ' , Q ^ ✓ 7' M 7' NAIL AtfB0Nlh1/ + ANGkE X .ssD' eaR: W/ I/4•/ 7APMN gT •MLL ® r A' x S' x .P50' Cone {p� (GISE A Qm 1, . • r ANGgRS • 17' nc w/ a7lfCETT,RIR�I + . � 4 •A x P 7/s• PUYE7a DOL7s o IC " ✓ R 7• Y J' x .7s0- cant ' ' •S�Ava cQvcEtR1d1T10N VAT/ON �140DDC'P REVISED ae cod" kylPlS'wbs4 98ie phioeddm ' POIA4ED *• QG AT lY'PE 1..Z 3 tr 4 510Mf eNR fDCA7pN (S� EJEL'ADNf O 1 /P }Q 4 iT b7DRN BIR ✓Pk:D4"YDC'1' idSPfSWBD SOME La.{710A; 1 D0.1T12,E DR LtYACRE7E Btacx AHD w/ arA:ENrRAfaN Or + B�7%8•A!Q t/4• PoMDPS BDL7S : 1/8' � t" REST a IP• O a ✓ aacv.'.r yl 8 - i 'f! v+6C6 toe &7Drlda J 1"_i•:. ''��`'^� L} REDWRED• 1 I' 4Q PDID7m AT i7r1PPEE 9 @ 8 SfD�/ 61R lOfaTpYLi „ CM�IEIE pR ;. ¢:ru°L.76:E''•, - 1 _==:.._�::: 8'uAlc X.20'00r.. AWNAYIid//'Y'7CASE FIXED STORM BAR CONNErriO/y. i4T 'BU/[O zft4•x I101 �*/8'r x7 t/*• PowERs Barry +ud®eaCamhol �" as C. O(/T ' �* >~/. /• Z ;' 4 4. SrBARH. (H.V..H.Z.) / MIAM/-OApE COUNTY INSTALLATIONS WfSHEF7 ' 1/t�7 A` cnoc ,AYD w/ coxcG7�mADDD°N� 'A R �LOG7fOM14S 0G 60mm .SLAT ROLL —UP SHUTTER AS SMJW s " SSG, Rani m D Ds SGffE': f/4' � 1� - SECTIONS V y b @ SIWW 8 TgE E,EL,A11aV X} . 1 L' E C 0 I1/5/02 ARE sRaw m AB04F sxDwN, w7RrouT — i - lime, ROLLINGSHIEW. INC. aF smRN Bw ! 1wAOD7s 7RAIr 1f11ANn ! YSP caw wfy 7500 ,AW. 71M AVEHUE AMW N,ANI 6$J HE JalIi x17— a /1-191 710R/0A M12.2imu:f>AiwIEB-OOOB7f9 t12^534 N Q 3 LQQ3 �r WALM? purr a P. E � Iaos . r� oaaneu aar DRAWING Na r r,r ' (IEraJ 1250 V-- A4ma.. TUBE' w/ r x A a E TD x O'�7• (ymJ ALUYRAetl/ to BU[D-pU( NgF i 1 • r r r . f2s• r>x:l. A1,n ABCr£ i/ ' r x ij ,) x aPS• fanE Aypn ' /r4 , .[/s• S11S o it a a 70 itl9E w/ z• x a'x , r2s• x o=1' (4a,) WIAP /iR , J/1• cur FA LEO 31 d UaL&CM ACHM O rr a a' rua LE1yO7N TO POMM aa4CRE1E I 'ALUMW AN'2E 70 BUID '•••.TtWV / J H x J 4• SYS FA {EO + % M. a a FlBL LEA'Orr1 70 POURM camm 'rF PoURED C n �all- REWM7ID ' PWRED / / CAMM REO r/ I j j� q II II 2cO0• Erv. rY P �2BCB i � A ' I� Ala 6 16 II' i I r II— J O©org 2000• ARn. ' IIBUBD OUf ME IIW'°'1e' . Ise I 3 J K ©orOM ' II 'r A IB q z' X r EctIG x .250' CMT.. AUAMM 1/4 1 TAPLLW Ate' 112' 4a W/ caN(EArsa m / OF I'3/d 1 x 2 1/1' POYERe WoS Osm"W all, - YaaAT77PE1,$ jd} ' Axn w{aa>NmArmN °E:"ix"` xJ' OR CONLiR7F a /JQ 1/f' PtlNER$ gt>L75 0 1' a4 / � &Drje etR rarArWltt •POLM CASE ON ' INSTALLATIONS WjSPR/NG L0.4D SYsrEu , SECTIONS V — �V ° °i'B PoR .�# < I' . 2•. .125' C.& Ak-ANGLE W/ 114 x 3/I• SNS o 12- a 4 TO nW s-R6 rLA�0flE0EB r r md SPR/NG-LaWM C Or SECTION S - S SINGLE STORM BAR ' SECTION S= S ; 1 s SCALE: 1/2° m T • r DOUBLE STORM BAR SCALE 1/2' a 1• Z -la4DMP � 3 SM f la I Y r c OO®' E OF Pf a' x r N°x r asB c°x1 r D© or Ff ACUN/NfM AN01F (GSE IJ AS APPMOLE ' ' -s/e•� x 2 T a/Powvrs'Bocrs o �• . A r AT TTPE I. , Ad 1 LW SRAPN 7IXitmW ANO 'AX2 t/1• "BAR P0R7RSB0a.T5 O 4. O,a AT TYPE 8 da B STORM 84R LMWAO £ I. J @@orO ° o ° r A I 12000 1Z000• .Oa' OW'--0.00D• N.000•-.-A000I 1.000'� 12000- ' ALfOCA4R% .2. - J(eLse0avL>7 r (eEmNeJ. / �:eonucr E QF Fl ELEVAT/ON/X \ - Biac>�p7ylOgmR�t40rh �F�9oriaa - eanrlu Sr4W. 1/8'. 1• - ±Ealaiaag C°do SFRLNO-LaY1ED=,cpaum lv 0eA, y Sl'S2U 4'?04itp00D7aionB 2' r a' x .250" CaA. r €'E.•IJ::`SC'y' yk;�[� (ems .,/ ar 4 rs r I r sus . LocAT7��Risr o 1a �4' X 6• daJL X .P50• a]NT. ALUMWIaI ' e/dca�mF hesae 2ta �°tDico➢ 7UE1E' W/ r/:'n TAMa7N 777via3w� 1ANCrprS D .12? a4 .W/ CCNCEMRA71aN - OF 1-J/B'B X 1' I/I• PoFii6 BOL75 p �•I' a4 Al tYAE lr2. S k I, - � F.B.L`. (H.U.H.Z.) / MG1Ml-OAD£ COUMY �W�QOaui"7A10C" 60mm SLAT ROLL -UP SHUTTER 1YSN0"" sa rla f/1• PowTles BOLaS o 1" a4 scar . AT F 5 k B S7aRN 84R LOCI710flZ - (SEE ELStATA^!1 XJ. 6CIfWI � JiemER 6P Cm'CRE7E QAB RONT �_ . SIDE. VIEW' TOP SPRING_LOADED SYSTEM. SCLE.. 1/2' = I" . J. TYPICAL CONNECTION TO r ' STORM BARS (SIDE VIEW} SCALE 1/2' e 1 • r R - Y r SFE' WDIMENSIONS FOR A 7YPF OF SWU BAR aarrmE C - f for f fa/82' o J 2(JS1' ,y yam• O f TJ/J1' .T 27/31' J r rAW. a fe/u• r zi/sx' s sa/az• f f9/SY• J 18/TL• FRONT p sA7 �E of mw av SIDE VIEW r BOTTOM SPRING —LOADED SYSTEM SCALE,' 1/2' = 1' - w.amc r - 112• eusLrR.� e. I A ts CWCREM / r/re• ' ENGAGEMENT HOLE DETAIL - (IN CONCRETE) FOR REMOVABLE PLASTIC BUSHING.•' SPRING -LOADED STORMI BARS ' DETAIL 1(ISOMEL_ - SCALE• 1' — I' • SCALE•• I' m r' F;€vaDUCIl Krveswm - Deco»y;r3yiogwiiWthe Noida co& aet cootml ���LR•L���ns�,s FIZZ.'. �.!:. :.A - \\ ICAL. SPRING -LOADED SYSTEM FOR REM©�BLE_ 4S AS ALTERNATE TO THE USE OF CAIXIN ANCHORS (H.M.Z.) / MIAMI—DADE,COUMff 60mm SLAT ROLL —UP SHUTTER suf>: Pamm nwisnr r. 1 rUre� r - fO+N�W/ x / 00� y4 ar A R0aglWUNOMOUMTM SECT101NW-WM WADHEAOFR SOWN W-WO WMEADER scALE : 1/9• a r R I I 1 I r, J•.u:rul,Mvc I 1 I 00aq P ELEVA MAV sour.. 1/e- - 1- ' r• a- IZY f(,L�qqfL, ' ArI,tlYY%AyW[ Y(/�ARYIM i 1 2• r uULU011S DEP/N r r/r' ' W *UP M:W 7U8E AAfalAS / r' 4 G PoURFO OOAYJ7E'7E' % UAVAGO µjaWrp' + REOU/RID j / MlXDR401Yf G C•-2• {y/ J 14 x J/4' & N. S.. FitNlEd + ------- Alm Nmmmww REDfi® /p I II 2'r 2'rW1 x!/QB�B'Mum 4E+/ NINUN ANGIEW �14r I •-^\� II N!N 490E �yTC h 2(2i1 �d/,- S M. S, / 2 G G + c�e! (" •rYxarTO mu WN.L/ II natu.eausrouuuati �. 000 URED , 7sD-.rD' r QDXO G QH (GV.Yfm W-wo i G OOR O rI 7.-s s , Y, L �S (Ol�lo /I{ r �/4- rxY'rn.•J-m $' ''IR"&�l*g;'n;;zPoGi;,•+ AMa r, 4 14'x .'i{'. �i PoWFRf 2'r 4'r Jf•x ' 8•AWm. ' '° ) ,t/9 a 75 TO rmue�' 7RAGS W/ fAW VWM m4 J/1 tmiT1M�TJl6Pr Hl• {IYIL(.m. A4GL6 ! FOR rASM W/ .i9tX.D-OUY nV& WA. I' i . ,,' AIYaEfOR - �i �R7stEp • ' J K L as M OO O ' DOOR W7�Nrow'I'mI I I I . E i 'r,-r��uaErmv D. WALL MOUNTING a SECMW W.W(J) . I I WALCINIOUNMAS: SEC7IONWW(8) ' SWZ) I/r• _ 1- acUf : 1/r• . I• + AM:I I I ?M OMWAM N X-ftY WM RR =m IKw w M - O©1O'L% I . M- 8MN - 91 a: LMM IMTN 12'-O' M. SINW£ mw a m ad W"W AMM LdW DR.Fat SMW 9MB MW wR~­a,I hnow uM ir-o• I a• {(p�R + Ia1L SMIE SW7 11 rD P". uw= Dam uKa 7ER fII16:�• Y � I mllal0 I I QDR© REolam I SEE NO0121 Irl 2a/�4' x 0'/ /21 �/B tb w7RU0L7 alga R Grida 10 NIPl is,YSet:lum O D WALL MOUNTING : MULLJONCONNEC770N + of o O I o Pcadact Caalriel ATTOP&B0T7W.jECT/ONWW(1) DWI" J'r J' AL16rrry AA1'aE - I (2) 2 r 4- 1/,' x O'-E' AWm ARGIE (4 r ,' l7lAU 601.T' m 1TrR f.� J� r r z 1 s• I 1 SCM.E : IA'- 1' + NOTE 1 : E'23�D6Vi5' G!E?/C13'3Il5 OJ O©0N M Po 9gCiS FAL11 W 1 1/2 lfin. PETelR1110N, + F7oSRNC WAIL MY 9E POURED Cg7CRE7E OR CONCRETE 9tNCR FOR :•,.:..: OE5/GY L6145 UP r 164'D P+r AAD S7WE BE' !'OI/REO CONCRETE OR . CONCRETE FN[ED SLOCKS FOR SRFA7ER La44a _ aGIA 'A7 ' GLGYA�IWaL-�] �•w.s'k4:v''r%r".4.iCl SCME: 1/r'- f + SfW.E't ;/r'� Div�a3:`.4 F.B.C. (H.M..Z.) / MlAMI_awE COuw 60mm SLAT ROLL —UP SHUTTER Tymu HEAOERCONNECTJONATEAM A I'L E C ROLLJNGSHJELD,°+�' r1/r/D2 SECTIONS VKW I M.C.. 2500 N.W. 74fh AVFJVUEJNC. _ SLAT.PERF.ORMANCE CHART ' MAXIMUM NEGATIVE DESIGN PRESSURE RATING AND CORRESPONDING .MAXIMUM :SLAT SPAN "L" FOR TYPE 1 SLAT. (USE NEGATIVE PRESSURE VALUES AS PER ASCE 7-98) i SEAT 7YPE AWOMUM MINIMUM SEPAk9770N SLAT SPAN TO GLASS ' Nac DpON L010 SINGLE k MUL77PLE SO/GLE g. MULIMLE SINGLE & (1>�L) UAW" UNIT •+ MULTIPLE DN1T,'•• ' 410 @-6• J• 3, 50.0 6•�•, 3• 3, 60.0 b=11•• 3' 3' 95.0 b=9' J• 3• Tao 7S0 .g_@• 3• 3• Sao b._b. 3• 810 J' 90.0 5'-2• J• J. 910 5=1'. 3• J- 100.0 g'_p• J. J' Mao 4-11•. J. J• iiao 3. ,115.0. 4t9• • ,3• 3• 12ao 4'•-B•- 3• 3' 125.0 4•-B. 3• 3. 130.04 _7•• 37 3• 1310 4'-B' . 3' .3• 14a0 4'-S' - 3. 3• 145.0 4'-5' 3• 3• 1Sa0 - 4'-i' . J' 3• . ino 16a0 4•-2• . J' J. 165.0 4'-1• J• 3• 170.0 4•-0' J' J. 1750 4'-p• _ 3• 3, Ifto 3=10' • 3' 3- 19a0 J'-10' _ J• 3• . 195.0 20a0 J'-9' • J' J• 2010 3'-B• . J' .. J. 2/0.0 3'-6• - J' 3' 213.o J-7• J•' J' _ 220.0 J•_7• J• 3' 225.0 J'-6• : J• J., !UA! 0 3 2003 C❑ ❑ ❑ F"- L —•{ l ❑❑ ❑ I —L—� 0 SINGLE SPAN ' MULTIPLE SPAN • SPAN LAYOUT - • SPANS VALID FOR EVERY INSTALL ?70N LOCATED AT ANY ELEVATION OF ' BURRING MEASURED AT BOT70M OF SHUTTER. MINIMUM USEFl%lloN TO OLASS FOR. SINGLE AND MULTIPLE UNRS SHALL BE MFASlTED FROM BACK OF SLAT TO GLASS. •� MW/MUM SEPARATION TO GLASS FOR SHUTTERS WSTALLE@ Mpy E �30'-O''ELEYg770N OF BUILDING AND MAaTA SPAk. SEf TABLE 1 FOR NP73 GLASS FOR SPANS LESS THAN 7N£ Max. ALLOWED. MINIMUM -M ARA770N 70 OLASS FOR SHUTTERS INSTALLED A@DYE 30 =0' � OF BURRING, MEASURED AT BOTTOM OF SHUT!!`R PPDi UCr RENEWED with the Florida ••'rrsNoO OS C$ ccar�o�ma p fv - INlemt DivePtvdaelCoetrol obbloa o cg 7GZ �,ei3 v�rdv�'P� 7Ya F.B.C. (H.V.H.Z) % MIAMI-DAnF rnuNry SLAT SPAN (R.) MINIMUM SEPARATION TO GLASS ' 10' OR LESS J. NOIE : 771E TOTAL SLAT DEFLECRON AFTER ADDING ' THE DEFLEC77ON OF THE HEADER AND/OR THE STORM BAR SHALL NOT EXCEED A MAXIMUM OF - 2' OR L/Jo IN 7Fl£ POSIIIVE DIRE0770M AND - A MAXIMUM OF L/30 IN THE NEGA77VE DIREC77ON (USE NEGATIVE PRESSURE VALUES AS i/IV — MANUJUM DESIGN ME I SMRU Ew '. _ 2' x 2' x .fa8" _ — — •• IM/g 2 mumi a1R� 2' x 3' x .125• Im 3 570M GAR 2" x 4' x .125' LOAD S701V11 81R SPAT 570Wf SW SPACM smew 61R SPo/0W0 G J'-0' 3' 70 4' 4' 70 5' 5' 70 6' 6• M &5' 3'-0''. 3' 70 4•• 4' 70 5' 5' TO 6' 6'_70 6.5' t 3 0' 3' TO 4'• 4' 70 5' 5' TO 6' 6' TO 6.5' 40 6'-0' 6'-0' 6'D' 6•-0' 6'=0` . B-p• B•_p• 7'-7' 7'-J" 7'-I^! J -0' 9'-5' 9'D' B'-7' B'-7• 45 6'-0' 6'-0' 6'-0' 5=f0' 8=0' T-e' 7' 4' V6 11' 6'-B• IW-0• 9'-0" B•-9' W-4' 8'-2" 50 55 6'-0' 6,-0' 6•-p• 61D'. 6'-0• . 5'-11' 5._9. 5._7.. 5' 0' '7'-11" 7'-7• 7'-5' i-2• 6'-.11' 6,-7° S-i° V-4" - 9'-5" 9'=61 W-0• 8'-f0' 8'-6` 8'-4' B'-1 7'-B` 7._9" _ 60 6'-0' 6 -0' 5'79' 3' S'- f' 7 =9' 7 '-3° 6'-7" 8 =2 ° 7-5"'` - 65 6'-0' 6'-D S=7' 5'-1' 4-10• V-7• 7� 7• 5'_4•, 5-9° _ 9'-11 1 B'-5' 7'_91 7'-1' - 70 6'-0` - 5'-11' 5'-4' " 4-11' .41- 7-6' -8" 6'10 6'-1' V-7° _ 8-11` 8'-J' . 7'-6' W-10' _ 75 e-O' S-9' .5'-2' . 4-9' 4'-6' 7-4'. V-7' 5'-11' 5'-5' - 8=9' B'-1' 71-1. W-7" - 80 6'-0' 5'-7' 5'-0' 4-7• 4'-5' 7'-3' 6'D' . 5'-8' 5'-3' 8'-7° 7'-70° 7'D' S' S•• .4'-f0' . 4' S'. 4'-3" 7'-1' 6'-2' 5'-6" 5'-}' - 8'^6' 7-7` B'-H" 90 5'-11' 5'�T' .4'-9• 4-4' 4'-2' 6'-f1' 6'-0• B-4° 7 S' 6_7• 6_0° _ 95 5'-10' 5'-2' 4'_7• 4-2" 4-0" 6'-9' S'-10`.. 5'�i' 4'-9' - 5'-3° - 7-2" 6'^5' • 5-10' - 100 'S=9' S'D` 4•-8• 4-1•. J'-11 W'7' V-9' 5'-1' 4'=8' - 8'-1" 7'-0• 6'-3° 5'-91 - 105 5'-8' 4 =l f'. 4'-4 % 4'D• 3'-10' 6•_5' V-7• 5'-0" 4'-7' - 7-11 • - 6'-10" 6'4" 5'-7' - 710 5'=6' 4-9' 4'-3' J-11' 3'-9' 6'-3' S'-5' 4'-f0' 4'-5' - 7'-8• 6-8` 6'-0' 5-5` _ 715 5'�5' 4-8' 4'-J'� J'-10' 3'-8' 6'_2' 1.-4' 4'-9' 4'-4' - 71-6` V-6"- f20 5'-J' 4'-7' 4'-11' J-7' 6'-0' S'-3' 4'-0' 4'-J" - 7�5° 6'_5" 5-8 5-3 _ 125 1J0 •5'-2' 5'-1 4-6' 4" ' 4' D' 3'-11' 3'-8' d'-7' 3'-6' 3'-5' 5-111 .5'_p• V-1' 5'-0' 4'-7' 4'=6" 4'-2' 4-1' - - 7'-3• 7'-1" 6'-3" 6'-T" 5-7 5'-6' S'-0' _ 1.75 5'D• 4'-s'' 3'-10' 3=6'J'-5' S-B' 4'-11' 4'-ti5" 4'-0' _ 5•_}1• 6•-0".5•_5• 4_71' - 140 4'-11' 4=J' 3'-9' 3',S'• J'-4' 5-7• 4'-10' 4'-4' 145 4'-10" 4-2• 3'-9' J'v5 .J'_3'' 5-6' 4-8' V-3' 3=10" _ 6'-9` 5'-10 5'-2' 4•-9 _ 150 - 4-9 4'-1' 3'-8 3-4' ' J-2° 5' S' 4'-B` 4'-2' Y-10' V-7' 5'-9" 5-1 4-B' 155 4'-8' 4'-D 3 -7' J'-J" J-2` 5'-4' 4'-7' 4•-1 • J•_8" - 6 -8" 5 - 5 -0, 4 -7• _ !60 4-7' 3.-11 ,3'-6 3�?° J'-1' 5'-.Y 4'-6' 4'7-0' -6, 4-11' 4-6 165 4'-6' 3'-11 • ' J --B' J' 2' ' 3'-1' 5'-1' 4'-5• 4'-0' 3'-B" _ 6'-3' 5 -5 4'-10' 4 -0' 170 4-5.. J-fO' J'-5 .3' 1' 3.'-0`. 5-l' 4'-5' J'-11• 3=7" - 6-2" 5-4' 4-10 . 4-5 _ _ 175 4'-4 J'-9,' 3-15 J'-1' •3'-0• 5'-0' �'-4' 3•-10 3'-6' B'-f' -3 4-8 4-4 _ 180 4-4 J-8 3-4 3'-1' 2'-11' 4'• 4�i' ' 3'-)0 3-B' _ 6-0'. 5-3 4-8 4-3 _ 185 4-3 J-8 J-4 3'-0' 2-1J` 4'-fp- 4�2' 3-8' 3-5" - 5-71 .-2 4•_7• 4-2 _ 190 4 -1 .3 -8 Jul J'-0' 2'-10' 4-9' 4'=2 3 -9 3 =5' - B -10 5 -1 46" 4 -2 195 4-2 3- 3-2 T-11' 2-10` 4=9: 200 4-1 J-6 J-2 2-11' 21L.9' 4-8' 4'-0' 3'-7" 3'-4' _ 'S'-9' 4'-11 4'_5• 205 4-0 • 3 -6 3 -2 2--10- 2-9' 4-7' 4 -0' J'- 3'-J' _ 5'-11' 4 -11 4•-4" 210 4-0 J :S 3-1 2-10 2-9' 4-7' 3'-if• J-6 J'�T' _ 51-7 4-10 4•_4" 3-77 _ 215 3-11 J-5 3-1 2'-9• 2'-8" ,4'-6° 3-I1 3'-6" J'-Y - 5-6 4-H 4'-3' 3^ _ 120 J-11. J-5 JD 2'-9' 2'-B' 4'-0• 3-f0 3ti5 J-2 _ 5-5 . 4-9 4'�7• 3-10 _ 225 3-f0 J-4 J-0 2-9' - 2•=7• 4•-5" 3-f0 Jv� 3-1 _ 5-5 -B 4'-2° -10 _ STORM BAR SPACING SHALL BE SUCH TMT'MAX/MUM SLAT SPAN SHALL NOT BE EXCEEDED. E PAoOUCF RENEWED vNi the Florida b car•.i;:cr No -OSf .06 �.apfirs7tm ®a dei6eaatlW --- irleio0 F:1•_ ' wl�BeP aast�xS/la DivEdoo F.B.C. (H.M.Z.) / WA41-DARE COL M (USE NEGATIVE PRESSURE VALUES AS PER ASCE MAXIMUM --__- ___ _ � 7Y1'E 4 SMW Bw 2- r 4' x .250` � .� n/ncvY•.gR YVIYYRClC' MYfIW61 1if E 6 stow aw . (2) 2' r 3' x .125' /'- . rm B 8214Y Bw. (2) 2' x 4' x .00' LOAD ' LOAD iY' (p.s.f.) BW ' •4' SMW Bw .99=6 sraeB Bw SAAgAC 40 45 50 60 65 `70 � J'-0- 11 =f0' 71 =6' It _x_ l0=8' l0'-6' f0'-4' J' TO 4' 11=0' 10 =8' f0'-5' 2' 10'-0' 9=9' 9'-7' TO 5' 10'-5' 10'-i• B.'-10" 9'-7' 8'-5• 8'-J' 8'-7' `5' 70 6. 9'-11' 9'�B' 8=5' 9'?• B'-0' 8'-+10' 8'-8' 6' 7 B.5' 9=11• 9'�8" B'-S' - - _ - < J'-0' io=3' 9=11` g'-8' W-51. 9'-J' g•_7` 8'-!1• 3' TO 4'• ir-4 B'-3"' f)'-0' B'-8' 8=7` 8'-5' 8'-3' 4' TO 5' •O-0.• 8'-9• B'-7" B'-4' 8•-7` . 8'-0• 7'_fo'' 6' TO B' 8'=71 8'-4' 8'-7` 7'-f f' 7'-9' 7'-7" 7'_6• 6' TO 6.51 B•-5' 8'-2' W-O' - - -. _ C.3-0' 14'-1• 13'-B'. 13'-4' 73'-0" 12'+B` 12'-B` 11'-J` r 70 4' 13'-1' 12'-9" 12.=5" 12'-1' 11'-10` it'-7' if'�5° 4' TO 5• }2-5' 12'-0' 11'-9• f 1 �S` 71'-2• 11=o' 10-9• 5' TO 6' 11'-f0' 17'-6' 7 17'-2• 70'-11 f0=8" 70'-6" f0-4• ,s' 706.51 fi'-7• 11'-3• 11-p• - - - 75 !0'-1' 9'-5' 8=11' 8'=H' - H=9' 8'-!` 7'-8 7'-4` - 12'-0 if'-2" 70-7 80 8=17 9'�3' 8'-8' B'-4' - 8'-7' 8'-0' 7=7' 1f'-f0' tf'-O` to-5- 9•_1r• - 8b 9'-10' 9'-2'- T-10' T-5• T-1• - 11-8 }0-Jo 10'•z3" 9 90 B'-8' 8'=0' 7=9` 7'-4' B'-11` - 71-6 -To '__8 10-i. 9-B• - B5 •9'-6' 8'-!0' 8'�5' 7'-A" - 8'-3• 7=B' 7'-'3' 6'-9° - 11-4 70'-7" 10'-0 9'-6" - too !QO 9'-5' 8'-9'7' 7t7• 7- 2• 8•-7• - _ 11 -2` —TO-5 8'-10 9'-5' f05 ' 9=4' 8'-,B' 8'-J' 7'-5' - a=0' 7'-fi' f0-4' 9-9 g-4• - 110 715 9'-2• 9=1' 8=7' 8=6" 7'-)f° 7'-9' 7'�i` 7•-7'7=4• - 7'-1f' 7'-5' ... 6'-11' .Bti•g•. 6'�7' 6'-2� - - TY 1 f0 -}0 fo•_2•. 10=!' g_7 8-6 g•_2• _ 120 /25 130 }35 140 145 B'-0• - 8 =1 J'8'-3• 8'-10' B'-8' 8=7' 8'-4' B' 1'• B'-0' TT-0' a 7'-7` 7'�S" 7'�3' 7=2• 76=11' 6'=9' 6=8 • B'-B B'-5• 6'-3 _ - - - - _ 7_9 7'-8' r-7• 7'-6• 7'-6' 7•_B• -7-3—'-• 7'-2' 7'-7' 6-11• 6'-10 .B•_B• 6'-7• 6'-6' e-4' 6•�i• 6'-1' 6'-0'-2 •Yi'-0" S'-! 1' S'-9• 5'-8` S-7` - - - - _ f0-8• 10 -7 1tl -6 f0-5 10 -4 9'-f!` g'-f 0' g•_.9 9-8 8 9'-6• 9-5 9 _3 8-2 9-p g•_/." 9-0 B•_!p" a-9 - J50 155 MO 8=6' 8'-5•6' 8'-4'8-3 r-r 6=8' 6 1 - 7•-4• B•_7• S•_7!• S'-1O' 5•�5• 5-4 _ _ 0-1 0-0 9-5 9=4 8-f4 -70 _8-9 8_7' B-B H-0 8-4 165 170 175 180 185 190 195 200' 205 ?!0 275 22D 225 e•-+' 8�3' 8'-1 ` 8'-0' r;f0' 7'-8' 7'-B' 7 =7' -7*-6' 7'-5• T-4 7z3' 7-2 r-J• 7=/' r-0' 6=f1' 8'-10' 6'-9' 6'-8' 6 =7' 6'-6' 6'-5' B'-4• 6-2" B•-I• s'v''• B'�-4' 6 �3' 6'-2` 6-i• 6=-0' 5-il' 5'=10• 5'-!0' 5'-9" 5 -8• 'S=r 5'-6' s'-11' S-10 _ 5 -9`' 5-8' 5- S-B S�5 5 -4' 5 _ 5 -7 5 -2 5-1 5-1 _ - _ - - _ - _ _ - - 7• Z' 7•-i" g'_f1• 8=f0" B'-9' 6'-8' 6'-7'-9 6'-B• 6 =5' B -4' 6-J' B'�3• 6•-2 6'-1' 6.'-0 5'-71" S'-f0 S'-9` 5 -8' S -7 S-6" S�5' 57 5'-a- 5'_6'. _ 5•�5• 5•_f• g•-0•4-9 BL2• S =1 5'-0` 4-l0• B•_2• . S-7" 5•-0 - 4-11 4-10 4-9 4'-7- 4 -7 4-5 4-5 _ _ - - - _ _ - - B -17 9-70 _9 9-8 ' B-78-0 -6 g 9 -i 9 - - s -2. 8-1 8 -7 9-g 8-10 B _g a,-8 B - 8-7 8-B 8 -8 8-8 - -6 - 8 -J B- a -4 8-3 8 _2 8-1 7-g 7 _ - J1uMM HAM SPACING SHALL BE SUCH THAT MAXIMUM SLAT SPAN SHALL NOT BE DfCEEDED. JUN we ao s•::::': �• :; c•:SS f5e Fwidn os GB 59 ■ e control Dbtlm IYR®tlDAIQ;F.' T�[:'tl8sak9 . DQ. F.B.C. (kVH.Z.) / MkWI-DARE C01 STORM BAR LOADING CHART RATING `°4V" (p, s. I) 'AND CORRESPONDING MAKIMW SPAN I" FOR V TYPE OF STORM BAR- AND ' StORAI BAR SPACING. WE NEGATIVE PRESSURE VALUES AS -PER ASCE 7-98) MAX, SPAN FOR STORM BARS. W/SPRING_Lj)An o sr_srcu MAXUIIlN DESIGN LOAD -1r / smw Bw 2' x 2' x .1Ba' rlAr.2 SMW BW 2' x 3' x .125' rrPs 3 sraw Bw 2' x 4' STORY MR SPAM ' NOW M MMM smw Bw view • � 3=0' 3' TO 4' 1 3'-0'• :i' 1O 4' � 3'-0' 3' TO 4' 40 4'-v.' 3'-4'. W-0' v-0, 10•-D• 7-9• 45 3'=1.1' 3'-0' .7'_1' 5'_4• 9'-2• 6'_11•' 50 Y-7' 2'-B" 4'-10' 6'-d• 6.2• 55 5'-10" 4'-4.' 7'-5' 5'4' 60 3=0' 2'-3" 5'-4' 4'-0' 65 2'-9' 6'-4' 70 24' .1'-11' 4'-7' 3'-5' 75 2'-4' 1'-9' 4'-3" 3' 2' 5._6" — or ulmc -b"AU ,= 50CH THAT MAXIMUM SLAT SPAN SHALL -NOT BE EXCEEDED. .STORM BAR LOADING CHART ►RE RATING '•W'. (p, S. f.) AND CORRESPONDING MAXIMUM SPAN "Let FOR 71VEN TYPE OF STORM BAR AND STORN BAR SPACING. . (USE NEGATIVE PRESSURE VALUES AS PER ASCE 7-98) 7 - MAX_ SPIN FIIO CM9M. 12AbC w/mnulw_. n• .— MAXIMUM DESIGN ' Law 7w 4 SMAW a* 2' x 4' x .250' TIDE a S%p BAR (2) 2' r 3" ---TYPE a SRMtlI Bw (2) 2' x 4" x .250' S1ORY BYl sliYmva " STORY BAR SPAa Atli SMRY B4R swdma , 6 3'-0' 3' TO 4' 4 3'-0'• 3' 70 4' 6 3'-0' J' TO 4' 40 l D -4' 7 -9' 10 =3' 9'-6' 14 -1' 12'-1' .45 9 -2' 6'-11' 9'-11 " B'-11 13'-B' T 0'-B' 50 B'-, 6' 2' 9'-B' 6'-0' 12-10' g'_B' 55 7•-6• ' 5' E' g=5' 7'-3' i1'-B' g'-3' ' 6D B'-1 T' 5 -2" B.17' 6'-B' 10'-B" 8-2- 6'-2' 9'-i 1 7'-5• 70 5'711' 4'-5' 7'-7' 5'-9' B•-Z". 6'=11' 75 ' 5'-5' 4'-ll 7'-1" 5'-4' B=Y 6'-5' . —-rAt,lU JHALL Lit SUCH THAT MAXIMUM. SLAT SPAN SHALL NOT BE EXCEEDED, P�i1S?i;.i P.d'WL�WED .. r.i:&1Le morwa E7 lwl BD)rb3au t dlAiul DlY,i',oA .. el L'p+21ag F.H.C. (H.V.H.Z) / MWut-nAnc rnHA HEADER LOADING CHART MAXIMUM NEGATIVE DESIGN PRESSURE RATING "W" (p. s, f.) AND CORRESPONDING MAXIMUM SPAN "L' FOR A GIVEN TYPE OF HEADER. (USE NEGATIVE PRESSURE VALUES AS PER ASEE 7-98) MAXIMUM DESIGN TYPE 1 HEADER 2' x .J' X .125• IYPE 2. HEADER 2' x 4' X .125' TYPE 3 HEADER 2' x 4' X .250" . LOAD (p.af. ° STORM ERR HMW S70RM' 84R HOW S7W1M BAR REAW S 5'-0' 5'" 7' .1 5 =0' :5' TO 8' . t .6'-0' 6' TO B' '. B' TO 10' 10' TO 12' 12. 70 14'. 40.0 11 -4' 9'-8' 13'-6' 11=2' 14'-11' 13'-f0.' 13'-1' 12'-2' 171-31 .45.0 10'-9" 9'-1° 13'-1' f0'-6' � W-5• IX-5'. 12'-6' 71•_5' 1p•_7• 50.0 f0'�3° 8'-8' 12'-Y 70'-0' !4`=1'13'-7' III -if, 55.0 9-8' 10'-4' '8'-7° 60.0 9-4` 7-11' 11'-61 g_1• 13'-�S' '12'-2' f0.'-f0' g'_fi• 9'-2• 65.0 8'-1i' %7' 71=1.' W-9• 1J'-2' 11'-8• f0'-5' 9'-6' 8'-10° 70.0 gtB• 7'-4' 10'-8' B'-5' 12 -11' 111-3" 10'-1° . 9'-2' 8'-6' 75.0 8'_4• 7'-f- 10,_J' B=2' W-6• f0'-10' 9'-9' 8'-!0• B•-J• 80.0 8'-1' 6'-!0' f0'-0' 7'-10• 12'-2' 10'-6' 8'-5' B•_7° .7'_f 1 . .8 5.0 ' , j'-10' 6'-7' g-8". _ 7'-6' 11'-9' f0' 2' 9'-7' B•-4• 7•_9• 90.0 7'-7' ' 6'-5' 8'-5' 7-5` It' 5- 9'-11' 8'-70' 8'-7• 7•-6' 95.0 7'- 5. 6'-J' W-2' 7'-J' 11'-2' 9'-8' 8'-B' 7'-1 f ° 7'-4° 10D.0 7'-3. 6•-1' 8'-71' 7=1' 10'-10' 9'-5' B•-5' 10$.06'-0' • 8'-B' 6'-10" f 0 =7' 9'-2' 8'-3' 7•-6• 6'-11 ° 110.0 6'-11' S'-10• 8'-6' W-9' 70'-4' 9-0" 8•_01. p_4• 61_9" 115.0 6'-9' 5'-B B'-4" • 6'-7' 10-2' 8'-9' 7'-10' 7•_2• 6•_g• 120.0 6•_7• . 5•-7'. 8' 2' B'-5' 8'-11` . 5•-7• 7•-8• 7._0' 6.4. 7'-6' 6•-f0' W-4' f3D.0 6'-4•' 5'-4' 7•-10' 11 M-6• 8•-3• 7'-5• 6'-8• B'-J" 1J5.0 6-3' S'-3' 7,-8' g'_1• 8'-4' 8=7° 7'-J" 6•_7• 6•_7" MAXIMUM DESIGN TYPE 1 HEADER 2' x J' X .125' TYPE 2 HEADER 2' x 4' X .125' TYPE J HEADER 2' x 4' X .250' IF LOAD (p.8d STORM BAR HE1GHr STORM MR HOW STORM BAR HEIGHr ' G'S'-0" 5' TO 7' S 5'-O't 5' TO 8' S W-O' 6' 70 8' 8' r0 10' 10' 1D 12' 12' TO 14' . 140.0 6-1' 5'-2" 7'-6' 5'-11' g'-2• 7'-11° 7•_1• 6•_6• 6'_0• 145.0 6'-D" 5'-1' 7'-5' 5'-10' 9'-0' 7'-10' 7'-0' W-5 150.0 5'-if" S'-0' 7'-3' 5'-8" e'-7D" 7'-B' 6'-10" 6'-3' 5'-10' 155.0 5'-ID' 4'-f f' 7'-2' 5'-8' 8'-8' 7'-7' 6'-9" 6'-2' 5'-9' 160.0 Y-9' 4'-70' 7'=7' 5'-7" B'-7' 7'-5" 6'-B" 6'-1" 5�-Y 165.0 5-7" 4'-9' .. 6'-lf" 5'-6• 8'-5' 7'-4" 6•_7• 6,-0•. 5•_6• 170.0 5 =6' 4'-B' 6'- f0' 5'-5' 4'-4' 7'-3' 6'-5" 5'-11' 5'-5" • 175.0 5-6' 4'=7' 6'-9' 5'-4° 8'-3° 7•_i• 6•-4" 5-10° 5'-4• f80.0 5'-5' 4'-7' 6'-B° 5'-3" 8'-1- 7'-0' 6'-3" 5'-9' 5t4' 185.0 5'-4" 4'-6' 6'-7- 5'-Y B'-0" 6'-fi° 6'-2' 5'-B" 5'-3" 190.0 5'-3° ' 4'-5' 6'-6' 5'-!" 7'-11" 6'-10' fi'-I° 5'-7' 5'-2' 195.0 5'-2" 4'-4" 6•-5• 5-1" 7•_9• •6•_8• 6•_0• 5•_6• 5'_7• 20DO 5-1' 4'-4' 6'-4" 5'-0' 7'-8` 6'-8' 5'-11" 5'-5' 5'-0' 205.D 5-1' 4'-3' 6'-J' 4'-li' 7'-Y 6'-7' 5'-11" 5'-4' 5'-O' 210.0 5'-0' 4'-J' 6'-2' 4'-10' 7•-6' 6'-6" 5'_1O• 5'-4' .4•_11" 215.0 4-11" 4'-2" 8'_1• 41-10" 7'-5" 6'-5" 5'-B' 5'-J" 4'-10' 220.0 4'-10" 4'-!" 6'-0' 4'-9" 7'-4' 6'-4' 225.0 1 4'-10' 4'-1° 5'-11" 4'-B' 7'-3' 6'-3' 5'-7• 5'-1" 4'_9" JUN 200-3 1+:u.T:•J:`r 4�.^ruru�l:9> 6`-3®T71ti �f itaSYCB'J.61 a:: .....�: Plaiiba m ca: •,w;,rs. _ tia•� F:lm GRer10a, ..per 3.1 5l3i�uaA Yit,S6T009Sd @9ea.tlST.�.F.. �'m".�QCaatr¢I . BDIvd+Po® Qlvi^x F.B.C. (H.V.H.Z.) / MWMI-DAOE COUNTY ' MAXIMUM DESIGN TYPE f MULLION TYPE 2'MULLION 4' x 4' x .T50' TYPE 3 AMLION 4' x B' x .TSB" LOAD MULLION SRJCING MULLION SH1fJNB . N1HlJON SPApNO 40.0 45.0 50.0 55.0 60.0 70.0 7&0 80.0 85.0 90.0 85.0 100.0 105.0 fT0.0 1i5.0 120.0 12ra0 T30.0 1.T'.i.0 140p 14SO' I50.0 i5ra'0 !7'a0 • iB0.0 ida0 _ 180.0 1950 200.0, 2050 210.0 215.0 220.0 225.0 t 4••-O' H'-B• B'-8' 8'-4' 6'-1' 7=10 T-5" T-3` 7'-2' 7'-0' 6'-f0 6'-9° 6'-7' F6' 6'-5' 6'-4" 6'- - 6'-2' ' B'-1" •6'-0" 5'-It 'S'-10 5'-9' 5'-9°5-4" 5'-8' 5'-7• 5'-7' $'-6"• $•-5• 5'-5' 5'-4' 5'-4' 5'-3' 5'-3' 5'-2' 5-2 5 -1 *--I-[4'-8' f' TO 5' 8'-4' 8-0" 7•-9• 7'-6• .7'_ 3 6-11 B'-9' 6'-71 6'-B' 6=4` 6'-3' 6'-2- 6-!'• 5•-11 5-10 g'-9- 5'-B' 5'-7' 6'-6' 5=5' S'-4' S',i' 5 _2• - 5'-2' 5-1' 5'-Y S._0. S _'p• 4'-t 1 4-fi4'-7' 4'-10 4'-!O 4'-8' 4 _9' S' TO r 7=10 7'->" 7'�3' 7-1' B'-JO 6'-6' 6=4'. 6-J' 6'-1' B-0' S'=i7 5•-8' 5'-8' 5'-7' 5=6" 5•_5• .5'-4' - S3' S'-2' S'-!' 5-1' 5•_0• 4-11 4'-l1 4=10 4'-!0 4'-9', .4. g. 4•_g• 4'-B' 4'-7' 4'-B`6'-J" 4'-6' 4-5'- 4-5' 6' TO 8' 8'-2" 7=10' 7•-7" 7'-4• Y 2' 6=10" .6,-8, 6'-6' 6'-4'. 6'=3' 6'-2' 6'-0• S'-11' S'-1U' 5'-9' y_B• S'-6" 5'-5' S'�5' S•_4• S-J' 5•-7• 5'-2' S-1' 5-f'6'-8` 5'-0' 5-0' 4-11• 4._10. 7-10' 4'-9' 4'-8' 4'-8' '4- Q 4'-0" !1'-9' 11'-3" 10'-1! f0'-7' JO'=3' 10=0 8'-9' H,-6, 9.4' 8'-2" 8'-77' 8'-JO'.g'-2' 8'-8' 8'-6' . 8'-5° 8�3' B-2• ' 7' 7•-10, 7--9' 7'_8• 7-7' 7•_6' 7'-5' 7'-4' 7-2• T-1" 7-1• 7._Q, 6'-i1' 6'-10' B-g" 6'-B" 6-7 4' TO 5` 10'-11 10'-6' 10=1' H'-10' 8'-6• ' H'-J' 9'-0° B•_10• 8'-8' - 8'-6' ' 8'-4' 8'-0• 7•-17' 7'-9' 7'-8• ..7-7" 7'-5' 7'-3' 7'-2' T-i• T-0' 6'-11' ' 6'-70' 6'10 % 6-8' 6' B'-B' B._6. 6'-5' 6'-4' 6-4' 6-3' 6 -2 6'-2'. 5' 7V 6' 10; �3' e'-f0' 9'-6' s �7' 8'-rf' 8'18' 8=6° 8'-4' 8'T' 8'-0• 7'-10' 7:-B' 7'-7' 7'=5' 7'-4' 7'-J° 7'-I' 7'-0' 6'-10' 6• -9• 6'-ti" 6'-7•E6110" 6'-6" 6-5' '' 6•-4•. 6�T' e'-3" B'-2' 6_1. B'-J' B'-0' 5'-11' 5'-11 ` 5'-10"�'6'_.Y 5'-10'.7=1-- 5-9� 76' TO 8' 70'-8' . 10'-3' 9'-1!' 9=7" B=4' 9=1• 8'-10' B'-8' 8=6' B•_.4' 8'-2° 8'-0' 7'-11' 7=9' 7'=8` 7'-6'. 7=5' - '7'-4' 7=3' 7'-2' 7'-f' 7•-0- 6-6' W-6" ' 8'-5' B _ 4 6'-4' 6-3' 6-2• ' 6'-2' 6'-p• .6 4'-0' 16'74" 15•-8' 75=2" . 14'-8° 14'-3' 13'-11 13'-7' 133 12'-11 F22-e f1'-5' 12'-3" 12'-D` fi'-10 li'-8° }1 -6' W-4' 11-2'. 11-0" 10'-'11 10'-e' .10•-8• 10'-5" f0'-3' f0' 2'170.0 10•_l• TO'-0° e'-!f' 8'-IO• 9'-9• 9'-8' 8-7' 9'-e J -5° 9•-4• g-2` 4' RJ 5' 't5 -2' 14'-7' 14'-0' 7J-B` 13'-3' IV-11 'f2'-7' 12=3' 12'-0° 11 -g" il'-4' 11'_2• 1}'-0` 10'-10, 10=8' IO'-6' 10'-4' 10-3• 10'-1' !0'-p" 9•-l0• 8'-8• 9'-B" .9'-Y . 91-4' 9'-3' 9=2' H._7. 8'-0' 71' 8'-10' 8-9' 8'-6` B•_B• B'-6` 5' Tr1 6' 13'-9` f3,'-i" 12'-f0 f2'-6° 12 .2' 71'-t0 1 i'-7• 11'-4' if-1' 10'-11 '70'-8• 10'-4' f0'-2' f0'-0' B'-9' g,-8• 0'-6' 9'-5' g,-,7• 8t2•9'_7•. B-1600 g'_B•9�_4"1650 6,-10' B-sue - B•_B• ..8,-7" 8-6' B'_ • 4 g'-2' B,-2'. B' 70 B` i4'-4' f3'-!0 13'=5° 13'-0° 12' 72'-4' 12•-f ° 11'-10 11'-7° 71'-4" f 1'-2' 10 =8 ` -10'-7" f0'-6° 10'-2" 9'iJ -fl, 9'-10" 9-8` W--2" H•_p" W- B,- 1 ! a'- to" B•_B' 8' 70 10 0'70 12 f2'-10 12=5' 12'-f' 11'-to 11=5' Il •_2• 11'-0" 10'-g° f0'-6' 10'-4' - 11=8' JI'-4x !o'-s• I0'_B• 10'-4" fptl• 9'-9' - - _ - - - _ - - _ _ _ - - - - - - - -_ - - _ - - - NO7E5.: REFER TO O"A77ONS ON SHEET 1 OF 16 ' 1-, FT1R M R IONS ASTA IED WA STORY PAW .A) MULLION SPACING SHALL *BE SUCH THAT MAXIMUM SLAT SPAN SHALL NOT BE EXCEOEO 2-. FOR MULLIONS MM= W/ CT/1RL BARS a i a Fnc A) MULLION SPACING SHALL BE SUCH THAT MAXIMUM HEADER SPAN SHALL NOT BE EXCEEDED B)-STORM BAR SPACING SHALL BE SUCH THAT MAXIMUM SLAT SPAN SHALL NOT BE EXCEEDED FS^l;RX EIE:NEWED OMP9UMiT1'. �n,}gr,,1L. the mean,ytA..^x ;a1;`a Gif®frLCeQt7n •r$@E7osids RRMI, eJr :4 L•_. T:n 04- 5f2.L A.rc:•tr�-c:.ha -O _.:,-..a:.:a.LS • G �G9 _ ib9 Mi mmduct CzatmP unaB :r-:s xd i.ersr.;9 ®Ivieiao D:r+kna FU.C. (H.1!H.Za / M14M1-DADE I M I A M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA, Gold Coast Hurricane Shutters, Inc. 4450 S.W. 61" Avenue (#10) Davie, Florida 33314 MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the. manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: (HT_10 - 64; C:�rofiWl Aluminum_Accordion-Shutter APPROVAL DOCUMENT: Drawing No. 03-807, titled " G. C. Profile ", sheets 1 through 7 of 7, prepared by Knezevich & Associates, Inc., dated October 17, 2002, last revision #1 dated December 04, 2002 bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises & renews NOA # 00-0417.07 & consists of this page 1 & approval document mentioned above The submitted documentation was reviewed by IHlIelmy A. Makar, P.E. ti 2 NOA No 03-0616.01 l Expicalion=Date-061021200A�, Approval Date: 07/10/2003 Page 1 '_-_i �► "'MIN FASTENER R(� 24" O.C. -..(USE A'NY'ANCHOR IN + ANCHOR SCHEDULE) E aL #10 x 1/2" GALVANIZED SMS OR 3/16"0 ALUM. POP RIVET . 18•.. O.C.. 1" x 1" x .055" ; 1''. x 2" x .055"- 2" x 3" x .055" ; 2" x 4" x .0t 8. 7 OR 2" x 5" x .125". AL. ANGLE gALT. CLOSURE DETAIL . SCALE: 3" = 1'-0"' MIN ' FASTENER.( 24" O.C. (USE ANY ANCHOR IN' ANCHOR SCHEDULE). #10 x 1/2" GALVANIZED SMS .:OR 3/16"0 ALUM, POP RIVET @P48".O.C. 1" k 1" x .055' 1 x 2" x .05S"• 2" x 3" x .055' 2 x 4" x .0t5 7.. OR 2" x S" x -.125" AL. ANGLE 8 . N ALT. CLOSURE DETAIL SCALE: 3" =.1'-0" V.x 2'" x 1/8" ALUM. ANGLE o 3 #10 TEK SCREWS A B 5" MAXIMUM ALLOWABLE SPAN SCHEDULE L E 1 NEG. DESIGN LOAD (PSF) TYPE A ALL. MOUNTING CONDITIONS EXCEPT, © OO . (FT - IN) -. TYPE B DETAIL (2F OR DETAIL © W/ SINGLE ANGLEREQUIRED REQUIRED 3-3/4" - MAX. B.O. (FT - IN) TYPE C DETAIL © DOUBLE ANGLE - 3'-3/4" MAX. B.O. (FT - IN) . TYPE D . DETAIL OE 9-3/16" MAX. B.O. (FT - IN) 30.0 13- 1 12 -4 13- 1 12 7. 38.0. 13- 1 11 0 7713-1 11 -2 40.0 12 - 11 10 - 8 12 - 5 10.- 11 480 12:- 4 : 9.79 10 - 4 10 - 0 f22,6--'12- 1 9-4 9-7. 9-7' 56.0 11 - 11 9 - 0 9 - 0' .9 _ 3 615 11 - 7 8 - 7 8 - 7 ' 8 = 1.0 63.3 11 -6 8-6 8-6 8-8 66.8 10- i1 8=3 8-3.. 8-5 67.5 10-9. 1 8-3 8'-3 8-.5 71.2 10-3 8-'0 8-0 8-2 75.0 9-8 7.-.8 7-8 870 81.4 8-11 7-0 7--0 7-4 86.8 8-5 6-'7 6-7 6-10 91.4 8-0 6=3 .6, 3. 6-6 . 100.0 7-3 5-9 5-9 6-0' 116.0. 6=.7 5-2 5-2 5-5 120.0 6- 1 .4.-'9 4-9 5-0 . 130.0 5-.7 4-.5 4-5 4-7 140.0 5-2 4.-1 4-1 4-3 15b.o 4 - 10 3.! 10'- 3.- 10 4 - 0 ' 160.0 4'-6 3-7 =3-7 3-9 110.E 4- 3 3- 4' 3- 4' 3- 6 OR 3-3/16"0 ALUM. o. 8 POP RIVETS (TYP.). NOTES: 2" x 2" x 1/8" o 1 #10 TEK SCREW OR 3/16"0' 1. .REFERENCE APPROPRIATE COLUMN IN TABLE 1 BASED .ON. ALUM. TUBE ALUM. POP RIVET (la 24" O.C.. MOUNTING CONDITION IN FIELD. 6063-T6 _ALLOY (TYP.) TWO 1/4"0 FASTENERS 2. FOR DESIGN LOADS BETWEEN 'TABULATED VALUES, USE EACH ANGLE (SEE ANCHOR. NEXT HIGHER LOAD OR LINEAR INTERPOLATION MAY BE, ( OR93SCHEDULE FOR ANY ACCEPTABLE USED TO DETERMINE ALLOWABLE SPANS. ANCHOR) 3. ENTER TABLE 1 WITH NEGATIVE DESIGN LOAD TO DETERMINE'. NOTE: MAX. SHUTTER -SPAN. EITHER CO:NDITION.MAY. BE TYPICAL FOR EITHER SIDE 4. ENTER TABLE 2 WITH POSITIVE DESIGN LOAD TO DETERMINE MIN. SHUTTER SEPAR-ATION FROM GLASS. CORNER CLOSURE DETAIL` ' P OSCALE: 3" = 1'-0 Z .. .. Q a� •. ., .. .. . MIN. SHUTTER SEPARATION.: 2" x 2" x .12S"'.' SHEETGSASS (SEE SCHEDULE 3Q. ALUM. ANGLE CONT. 0 0.062" THICK .. H --I~ RECESSED SILL -I- QLu 3105-H32 OR 6063-T6 ALUM. " Xo. ' 10 OR 0 ALLOY (1/8" BELOW: Qw 1/4-20 TRUSS -HEAD CONCRETE)'-. X Yu -BOLTS & NUTS W/ Q ww A B MINIMUM SHUTTER SEPARATION FROM GLASS (IN) L E 2 POSITIVE DESIGN LOAD (W) (PSF) ACTUAL SPAN (FT - IN) MINIMUM. SEPARATION ' FROM GLASS FOR INSTALLATIONS LESS THAN OR EQUAL TO 30' ABOVE GRADE (INCHES) MINIMUM SEPARATION FROM GLASS FOR INSTALLATIONS GREATER THAN 30''ABOVE GRADE .' (INCHES) 30.0 5 - 0 2-7/8 1-1/2' 7 - 0 2-7/8 1-5/8 . 8 - 0 2-7/8 11 - 0 3 2-1/8 3-3/4 2=3/4- 4010� .5 - 0 2-7/8 1-1/2 7 - 0 2-7/8 1-5/8 8 - 0 .2-7/8 T-5/8 11 - 3 .2-1/4 3-3/4 3 ' .50.0 S - 0 2-7/8 1-1/2 7 - 0 2-7/8: 1-5/8 8 - 0 2-7/8 1-3/4 -11 - 0.` 3. 2-1/2 12 -'2 3-3/4- 3 60..0 5 -.0. 2-7/8 1-1/2 7 = 0 2-7/8 1-5/8 8 - 0 2-7/8 1-3./4 11 - 0. 3 1-3/4 3-3/4 3 70.0 S - 0 277/8 1-1/2 7 - 0 2-7/8 1-5/8 r 8 - 0 277/8 1-7/8 9 - 6 3 2-1/4- 10 - 4 3 2-5/8 .80.0 5 - 0' 2-7/8. 1-1/2 7 - 0 2-7./8 : 1-3/4 8 - 0 2-7/8 1-7/8 11 - 0 ' 3-1/8. 3-1/8 12=1 4 4 90.0 5 -.0 2-7/8 1-1/2 0 2-7/8 1-3/4. . 8 _ p 2-7/8 2. 11. ; 0 3-3/8 3-3/8. 11 - 6. 3-7/8 4. 100.0 .. 5 - 0 2-7/8'' .1=1/2 7 - 0. 2-7%8 1-3/4 8 - 0 2-7/8 2 9- 0 3 2=3/4 10-3 1 :3 3 . O9 OR9a LOCK WASHERS p w 24" O.C:w. . _ a ° a° EXISTING STRUCTURE EXISTING. STRUCTURE ° ° " _ ;.',. .°° `. MIN., 3,600 PSI CONCRETE CONCRETE FASTENER (al 8" O.C. 'ANY SCHEDULED FASTENER IS g HALF OF BO ° e ACCEPTABLE . USE MALE OR FEMALE AS REQUIRED OALT. CORNER CLOSURE DETAIL ALTERNATE AOOR MOUNT DETAIL.. Q SCALE: 3" = 1'-0" O SCALE: 3" = 1'-0" Uz m ZF 0 m � u W LL Q W .FoW ¢n w U. F- 7 O - O Qo cc J Q pU ` �mi co V1 N • Nd,. O m z V = N o_' W Q W 'I_V W ~ I to 2 Nd z = W. C O � N 0 Vt7 W Z co N O N. (l1 wJ.zm ® 11.1 U Lu ZZ Z 3 p Y Ov.'� ^�" O . 0 to WU�� z �k v it w�MTO, '. � F w Dmeeo >M46 IL QaNN x. ti°rnm z fOi+ turnIx a: 0ahlaixoL ION VJ. KNEZEVICH ' ' PROFESSIONAL ENGINEER ' FL Llceme No: 10993 Qo� 00.1 t] Nco Z a N no Q ' C o'er. ">:. S >. lO 0 y V 0 � Y � PR011UCT REVISED As complying with the �Eorida` SuldingCode'. L L` 1 Acceptnucc No.(3 �' O v. / ' EXpIFat10D'®ate t) Q 8 ]BY u Aul* IVfliami Dad .. lOdLLCt . , n ivl O ° nco . dahe 10/17/2002 scale drawn by AS NOTED design by checked by VJK VJK drawing no. Division : 03-807 " sheer 5 of 7 E c d _ - 2.420" 048 _ A02S--- t2 48" .966" .875' 833 X.1. 40" o.840" M,A rn 83".875". 83840m o0 1.875 .483"125" �' 2.420"1.685" t2 2 0 o.. t 945" 600" b20' 65600"620' 1533 00r . j t2 t2 2 cv 90' in 00' (T N t2 TYP. 2) t3 i -t2. 1I t1 o to 055' o o o o r N (TYP.1 1.250". V N �, U o°D 9 60 tom au 600" �m �0 00 " `° - N °` 055' 90' END SLAT z~ .m �. �- t1 } t1. .. � �0 91.5 2 t2 t2 �i o. O m N o N t1N 1 N 1 o r .055 m. N 6d SCALE: HALF SIZE w o 107" 1 - t1 1 N a` m (TYP.) m N .641" .FW :.; o S 0 1.193" ml o - - 93„ t2 .752" ni 1.250" W I.o C� t1 t1 1 r 84 136'' 1.250" u Lu a o t1 = .055" _ t1 = .055" N i fit t3. 711" 1.533" 985" F o j o t2 = .076" .... t2 = .076;; , (TYP 2) 00' Qo g t1 055" .326„ 620•, 1 = .055 V .097 - ttcn t2 = .076" .840' t2 = .076' 055' 250" g N = w HEADER CL 3. = 50 MOUNTED NEOID RALL MOUNTEDV m • cri 0'.' 3.283" .050" W TSCALEi HALF SIZE 2 ALE: HALF SIZE B ALTERNATIVE QW '=' `erns nwi ~ BUILD -OUT WALL HEADER SILL -WALL MOUNTED ADJ. SILL -TOP ADJ. SILL-BOT. . 2a SCALE: HALF SIZE OSCALE: HALF SIZE OSCALE: HALF SIZE ADJ. HALF 512E 5d ADJSCALESIAL FBOE. OFLAT END SLAT aS0 a Y I. 3.99.31, ALE �� o c W 52" 2.775" 2.984" 3.245" 3.465" co o' W 1 4.478" - N ADAPTER SLAT 2:586" 2.795" ' " :. 3.049" 3.267 .. Z N N W Sd SCALE: HALF SIZE 84" . 13 w J ZLI w ® U - Nam. La 5510" 1.D 510" LD. z o c 630"' O.b. o o .630" O.D: �Lu . C14o Q .: N N 65" LD. 52" N 165' "L0. 1 N 45 ..4.078" �� .1655" I D .285" O.D. rn tO .I.D.N..285O.D. 4.534' R, 248" 8 " b.b� m m" 0 D :O SCALE: E N 2 0 . SLATS 060' M .060" HALF SIZ 60'" 60" I N N N 4I 0 0 0 1.039" 060" 1.039" CD 4 4m moron 060" L9 N•19 ,060"ui N . 060" r 0 7F� GENERAL NOTES: 60 60" .m ._ . ' ' .= �'., 60 hk860„ ago = 6 5" T. THESE APPROVAL DOCUMENTS REPRESENT A SHUTTER SYSTEM ANALYZED WITH 345" 60 345" THE PROVISION SET FOR THE IS SUANCE OF A NOTICE OF ACCEPTANCE (NOA) BY MIAMI-DADE COUNTY PRODUCT CONTROL DIVISION FOR THE FLORIDA BUILDING BO .095" . gpr o 9 CODE,:2001. 250" C. . m . 0 42A. 0 � 50 .2. TO VERIFY THAT THE ANCHORS AS TESTED, ARE NOT OVERSTRESSED IN THESE 442" m 949" ?.949" APPROVAL DOCUMENTS, NO INCREASE IN. ALLOWABLE STRESS WAS USED IN THE �94 2" •• FASTENER ANALYSIS. 1.391., .. .p659" - 1.391'` 422.10159 • 9 3. DETERMINE THE POSITIVE AND NEGATIVE DESIGN LOADS TO USE WHEN "REFERENCING 1.891 1.8911, " 4. THESE DOCUMENTS IN ACCORDANCE WITH THE GOVERNING CODE AND GOVERNING -WIND VELOCITY. FOR WIND LOAD CALCULATIONS IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2001 A DIRECTIONALITY FACTOR OF Kd =0.85 SHALL BE use0. CENTER MATE 1 CENTER MATE 2 CENTER MATE 1 (w/LOCKING ROD) CENTER MATE 2 (WI LOCKING ROD) 4. THESE APPROVAL DOCUMENTS ARE GENERIC AND'DO•NOT INCLUDE INFORMATION OSCALE: HALF SIZE SCALE: HALF SIZE 9d SCALE: HALF SIZE SCALE: HALF SIZE FOR SITE -SPECIFIC APPLICATION OF THIS SHUTTER SYSTEM. Wz U o - uiam:o ' K W t7 to Q! w omIDto r Wmam IL S aarnrn o tea:- LL n a' U '3t^_IX a.. N<F-W �.0o . a F V N .. o U Kf ❑ V . o U S. ,THESE APPROVAL DOCUMENTS COMPLY,WITH CHAPTER 61G15-23 OF THE FLORIDA ADMINISTRATIVE CODE. .2. 812 VJ. KNEZEVICH 6. . THESE APPROVAL' DOCUMENTS ARE SUITABLE TO BE APPLIED BY THE CONTRACTOR . 0 4 0', 312' • ' PL License : PE 109PRO ESSIG E PROVIDED THE CONTRACTOR DOES NOT DEVIATE FROM THE CONDITIONS DETAILED STAINLESS STEEL 14'= HEREIN'AND THE CONTRACTOR VERIFIES THAT THE EXISTING STRUCTURE DOES " •430„ . „_375" , g56" 322 NOT DEVIATE IN EITHER FORM OR MATERIAL FROM THE STRUCTURAL SUBSTRATES ASSEMBLY S �7 j� DETAILED HEREIN. ° 37 - 0 {-� . 15'.' S17" 320"� HOLE 485" ;n 214' 7:' ANY MODIFICATIONS OR ADDITIONS'TO THESE_ APPROVAL DOCUMENTS WILL VOID p to �O L J I I I I N THE APPROVAL DOCUMENTS.. 1- ( I i 15" : m.' .- o NYLON WHEE 8. WHEN THE SITE CONDITIONS DEVIATE FROM THESE APPROVAL -DOCUMENTS, THE' N N RRI ECEED ( I I : I I o I I BUILDING. OFFICIAL MAY ELECT ONE OF THE FOLLOWING OPTIONS: 97 N I rn 11-IJ n' inao 6 8,. 1.115 -[322"A) REQUIRE THATSITE SPECIFIC DOCUMENTS BE PREPARED, SIGNED, DATED AND' = SEALED BY A LICENSED ENGINEER OR REGISTERED ARCHITECT WHICH DETAIL 1.100" 251. i I rm 80' . AND JUSTIFY .THE DEVIATION. SAID DOCUMENTS SHALL BE SUBMITTED.TO'THE 230" i mom. I PRODUCT ENGINEER.FOR REVIEW AS A CONDITION TO THE BUILDING OFFICIAL MAX. 88 7H . GRANTING HIS/HER APPROVAL. 2" MIN:-5" MAX. 761.400" 76 I : = z TYP. AT EVERY OTHER o m INSIDE JOINT AT TOP. TOP' . BOTTOMMAX. CARRIER MAX 1/8'. CK STAINLESS STEEL. B) 'REQUIRE THAT AONE-.TIME SITE SPECIFIC APPROVAL.BE APPLIED FOR AND o o O SECURED FROM. THE MIAMI-DADE COUNTY PRODUCT CONTROL DIVISION. ANGLE - ROLLER ASSEMBLY BUSHINGS INSERT LOCKING ARM c O WHEN THE SITE CONDITION DEVIATIONS OCCUR WITHIN THE HIGH'VELOCITY HURRICANE -.(BANGLE' -' SCALE: HALF SIZE 22 SCALE: HALF SIZE 2 SCALE: FULL SIZE 13 SCALE: SIZE 14 SCALE: HALF SIZE : ' 0 a o to ZONE AREAS; ONLY OPTION "B" SHALL BE ACCEPTED BY THE BUILDING OFFICIAL. u co 9. EACH SHUTTER ASSEMBLY. SHALL BE PERMANENTLY'LABELED AS FOLLOWS:' - GOLD COAST HURRICANE SHUTTERS, INC. DAVIE, FLORIDA - } j {T i a I' MIAMI-DADE COUNTY PRODUCT APPROVED - 360" 10550" t7 .472" I.D. iv 80' 375' .435" R' PROD.UCTREVISED.. . o - 10. ALL SHUTTERS SHALL HAVE A LOCKING MECHANISM AT CENTER OR SIDE CLOSURE 2.373' �- t } o R 135" R . N "WITHIN 18•' OF CENTER (VERT.). LOCKING MECHANISM SHALL BE LOCKED TO PROVIDE }1 �. - C0� I w ' HURRICANE PROTECTION. .158' .44 o Braiding Code" ith 612" 0 D 0� fMe )rtorida ' _ :- l . R m .. O Aecept$ncc No. 505" 11. STORM SHUTTER EXTRUSIONS SHOWN SHALL BE 6063-T6 ALUMINUM ALLOY, U.D.N. ` 00 Expi NonDI ' o' 00g date 10/17/2002 12. ALL SCREWS AND BOLTS TO BE 2024-T4 ALUMINUM ALLOY, STAINLESS STEEL, ui �. u? 211 I t2 t2 t221.1" 150" 315" R OR GALVANIZED STEEL.WITH A MINIMUM TENSILE STRENGTH OF 60 K.S.I., U.O.N. 1510 1 1 pb cafe raw by POP RIVETS TO BE 3/16"�, 5052 ALUM. ALLOY, U.O.N. }1 - .055" B3 ' .8 83 ' vy. SAS NOTED d n MCR 13. TOP AND BOTTOM DETAILS M'AY' BE INTERCHANGED AS FIELD CONDITIONS REQUIRE. 1.350" 5001, }2 = .076' - " p Q Wi i design b�ty` checked Ky t 200" fi91t3mi raduct iDivi$igls 14. FLOOR TRACKS MAY BE REMOVABLE AT NON -STACKING LOCATIONS., USE � (OPTIONAL) - ' ' drawing no. REMOVABLE ANCHORS. sucH As POWERS CALK -IN ANCHORS. WALKOVER SILL LOCKING ARM ALIGNMENT' INSIDE HANDLE 03_807r 1S. THIS SHUTTER SYSTEM IS PATENTED WITH THE U.S, PATENT. AND TRADEMARK i5 LOCKING CLIP 16 FLOOR MOUNTED �� BUSHING (NYLON) 18 SHIM (NYLON) OFFICE," PATENT No, 5,755,270. O SCALE: HALF SIZE O SCALE: HALF SIZE . O SCALE:. HALF SIZE SCALE: HALF SIZE sheet"I of 7 05 05.03- 10:27. E ti. VARIES - NO LIMIT SINGLE ARM LOCKING CARRIER BUSHING 12 ,4 MECHANISM AT CENTER O TOP TRACK OR SIDE OF SHUTTER'..'. NYLON SECTION LOCK MAY BE INSTALLED ON HANDLE 12 2-1/4' INSIDE. OR OUTSIDE OF SHUTTER 7/16" O.D. 0.63" LONG NYLON I I II .I! TOP BUSHING PLAN 50.,�. z VIEW ! ! I I 8 z a a. a In In in N. Z ALT. LOCATION LOCKING MECHANISM OF Z (DOES NOT REPLACE #10 x 2'" SMS. -MANUFACTURED Ir o' ' AT SIDE SINGLE ARM LOCIO : FROM #410HT OR 18-8 STAINLESS .SINGLE ARM LOCK OPTIONAL CLOSER HANDLE STEEL W/ XY�AN 5200OFLUOROCARBON COATING0 Ln V) N.T.S. N.T.S. STAINLESS STEEL WASHER _ w SINGLE ARM LOCKING (TYP-: TOP &BOTTOM) iw Q Q MECHANISM AT CENTERAl (L SIDE OF SHUTTER. NYLON : Q LOCK MAY BE INSTALLED ON HANDLE:OR. '. 8" E \ INSIDE OR OUTSIDE OFSHUTTER .- 2-1/4 11 3/8" O.D. x 0.90" LONG NYLON I I BorroM BUSHING 2� LOCKING. MECHANISM .. USED WITH PIECES (RAND #10 x 3",SMS. MANUFACTURED BOTTOM TRACK CAN BE Ca18".ABOVE FROM #410'HT STAINLESS STEEL " -W/.XYLAN 5200 FLUOROCARBON :.OR BELOW. CENTER (SEE GENERAL NOTE 10) (DOES NOT REPLACE COATING & .460"0 x .050" THICK 300 SINGLE ARM LOCIO SERIES STAINLESS STEEL WASHER )'{CAL ELEVATIO LOCKING PIN SINGLE ARM LOCK OPTIONAL CLOSER HANDLE (TYP. TOP & BOTTOM). SCREW BUSHING & ROLLER/ N.T.S. SCALE: 171/2' = 1 _0 .' : N.T.S. N.T.S. BUSHING ASSEMBLY SCALE: HALF. SIZE MIN. SHUTTER SEPARATION. .MIN. SHUTTER SEPARATION FROM GLASS—SEE"SCHEDULE FROM GLASS. (SEE SCHEDULE. u o FASTENER O(� 24".O.C. SHEET 5). DISTANCE TO BE FASTENER (a� 24" O.C. SHEET 5). DISTANCE TO BE (SEE ANCHOR SCHEDULE MEASURED FROM BACK OF FASTENER (� 24 O.C. (SEE ANCHOR SCHEDULE MEASURED FROM BACK OF. FASTENER 24" O.C. ui FOR ANY ACCEPTABLE SHUTTER BLADE OR FROM `� MID (SEE ANCHOR SCHEDULE 2 MI FOR ANY ACCEPTABLE SHUTTER BLADE OR FROM (SEE ANCHOR SCHEDULE 2" MI W mm ANCHOR). HANDLE WHEN MOUNTED" FOR ANY ACCEPTABLE ANCHOR). HANDLE WHEN MOUNTED FOR ANY ACCEPTABLE w .Zmlo�o INSIDE. ANCHOR). INSIDE. ANCHOR). r ' >"vo Q¢NN E .L x F°rnrn INSIDE W/ -INSIDE AND�E W% O w rc�au`ti T EXISTING T EXISTING SHIM GLASS SHIM GLASS < � rnm IL. 0QFw� Z_ Z ' w F _ 18 , 18 U N ..13 100' 13 100' U 0 V o 14 O O 14 7ED (TY.P.). 10 (TYP.) 09 17' (TYP.I 17 (TYPVJ. KNEZEVICH 6-1/2" O- 6-1/2" - PROFESSIONAL GINEER SINGLE ARM LOCKING SINGLE ARM LOCK " FLLicenseN 109a3 MECHANISM AT CENTER MECHANISM AT, CEOR SIDE OF SHUTTER. OR" SIDE OF SHUTLOCK MAY BE INSTALLED . " LOCK MAY BE INSTON INSIDE OR OUTSIDE ON INSIDE OR OUT OF SHUTTER TYPICAL PLAN VIEW. OPTIONAL PLAN VIEW SC LE: 3'• = 1'r0.. R= 1._0.. -0- SCALE:. - OF SHUTTER .3". . SCALE�.3.. - 1. 3/4" MIN. 1 f4" MIN. NfBLY .. N m 4 & EE FASTENER SCHEDU 1=1/2" MAX.. E FASTENER SCHEDULE -1./2" MAX. SSE .. c = OPTIONAL LOCATION o N " : S. 4 & `^' ... T - .. I' T C5CONNECTION 1fa o 0 1" x 1" x 1/8" SSE BLY T" x 1" x 1/8" REFERENCE ANCHORy In ALUM..ANGLE W/ 'OPTIONAL ..I t' I..' SCHEDULE FOR MAX. ° U)i ' ® 3/16` 0 POP ACCESS HOLE 3/1b"� POP .SPACING _ 9 0 � RIVETS (a 6" O.C: c EXISTING EXISTING = 0* STRUCTURE " STRUCTURE PRODUCT REVISED ` ' > Q — / .. .. as cbLuplying.with the Florida OPTIONAL. BnidingCode DRILL 5/8"0 HOLE FROM JOINT BETWEEN SEE SECTION B ON SHEET 3 JOINT BETWEEN SEE SECTION L ON SHEET 4 Acceptance.No 3-o6lr��a'1 - BOTTOM OF EXTRUSIONO REMOVABLE AND FOR COMPLETEINFORMATION REMOVABLE AND FOR COMPLETE INFORMATION Expi tnon®steb Oo8 BEFORE FOR FIXED SILL. FIXED SILL . . . TRUSS HEAD BOLT.(TYP.) . CSC ONNECTION TYPE C4 CONNECTION TYP£ date. 10/17/2002 _ .. _ ., .. cafe drawnby RE ERENCE AN H.OR ,.. REFERENCE ANCHOR SCHEDULE FOR MAX. SCHEDULE FORMAX. jy' IDa POditit©t1tS®I SAS NOTED MCR' SPACING SPACING .. .. . Division .. .design by checked by PLAN VIEW . SECTION S PLAN VIEW SECTION T VJK V)K REMOVABLE FLOOR TRACK DETAIL OPTIONAL REMOVABLE FLOOR TRACK DETAIL 03�8�7 SCALE:.3.._ 1'_ 0.. SCALE : 3'= 1._ 0.. sheet 2 of 7 05/05/03 10:27 .' (1�1 CONT. - FOR LARGER SPANS EXISTING CONCRETE, MASONRY. '. =•� ri. k7 EXISTING CONCRETE, MASONRY EXISTING CONCRETE, MASONRY NE TWO 2" x 5" A.L. ANGLES OR WOOD STRUCTURE. SEE OR WOOD STRUCTURE. SEE OR WOOD STRUCTURE. SEE EXISTING CONCRETE, MASONRY. ;� (SEE SCHEDULE 1 TYPE C) ANCHOR SCHEDULE, TYP.. �. ANCHOR' SCHEDULE; TYP. OR WOOD STRUCTURE. SEE C2 CONNECTION TYPE' ANCHOR SCHEDULE; TYP. C2 CONNECTION TYPE ANCHOR SCHEDULE,. TYP. REFERENCE ANCHOR . REFERENCE ANCHOR ECi: EQ. EMB ,::4 Cl CONNECTION TYPE SCHEDULE FOR MAX. 2" x 2".x ,050" ALUM. TUBE EMB.: s REFERENCE ANCHOR SPACING BUT DO NOT Mg 4,? TYP. TOP &BOTTOM .. . SCHEDULE FOR MAX. SCHEDULE FOR MAX. EXCEED 8-1/2" SPACING SPACING r 5/8'` MAX.'�1/2" SPACING 1/4-20 MACHINE BOLT W/ ' ROLLER ASSEMBLY 12 ' °O C4 CONNECTION TYPE (TYP.) UT 12" O.C. (TYP.; TOP — 1/2" 1/2" TYP. E.VER.Y.OTHER P w REFERENCE ANCHOR BO�TOM) W F 4 z O : SCHEDULE FOR MAX. *Fti 2 O SPACING 1L4 pw a ti 1/4" MAX: 1/4" MAX. '�. MAX. 1 1/4" _ . z MAX. EDGE'' z z Z Q� - DIST. z Q� z Q_ . a w� SEE TABLE 2' : Q� a n� a vain 8 3Q OR DOOR w wNQ SEE TABLE..2 3Q SEE TABLE 2 ' c� 3Q ' . SEE .TABLE 2 W off j_ to 'I ¢ OF a1- 1-• J 3'/16"0 POP RIVET 8 p 3 " W J W q I-'jJ OR TEK SCREW "., = Zow O8 JW OS JW OR DOOR = QQ @ 6" O.C. (TYP.)' w (LSD GLASS 3-3/4" MA p Qp OR DOOR ¢p. E N aw . • O & 55 X v►QW OR DOOR XQ` 3-3/16" Xp o° X zu ASSEMBLY Q' X= X E� :. .. ' MAX. a2 . .. ,r .. P� X N Q Wv): 1" x 1 x 1/8 stun.' DIRECTION Q ¢ Wtuii N z w ALUM: ANGLE I>'1'P.) z W z w f POP RI.VET'. toLill In >� RIVETS. @ 6 0 C: MAX. (la 6U.L. (TYP.) -1/4".MAX. tn o wp - rY." 1/2" . �o - 1/4' Uul >r OPTIONAL FASTENER cq �;. MAX.. p o 'MAX_ LOCATION IN LIEU OF ANGLE TOP &'BOTTOM — 1/2' 3O 'n k-. O3 SUPPORT -'STAGGEO R — Lj U9 Z N v, u U Z Z i— m' O vi W 0 W V D V im o. ¢ °C o. O'• coois OR N S Vi • N Yl = S aW > w W Ln N dZS z 0 Y 07 UW N o O W Z N N col ma > ® {)Z,I (J IV> a ,ii 52 LL Z Z en m C.,1 � o z N R o Yo o EMB. Cl CONNECTION TYPE w p CS CONNECTION TYPE i ' ANCHOR 1/4" OFF CENTER :, • C2 CONNECTION' TYPE Lo C2 CONNECTION TYPE _;. REFERENCE ANCHOR EMB. o :x DEFERENCE ANCHOR CS CONNECTION.TYPE = : SCHEDULE FOR MAX. �• - REFERENCE'ANCHOR: u 0 REFERENCE ANCHOR SCHEDULE FOR MAX. REFERENCE ANCHOR =; SCHEDULE FOR MAX.'.. z S.CHEOULE FOR MAX. 1/.2' SPAGNG 11' - Sao SPACING SCHEDULE FOR MA.X: �% W - SPACING MB.. �{ i vi 9ka c. .. - 11 CONT. - FOR LARGER SPANS.' - �mmm -SPACING BUl-'DO NOT 0 5/8" MAX: _ SPACING EXCEED 8 1/2" SPAC NG (SEE SCHEDULE 1 TYPE CIL %GLES �..wmvo . U 5/.8" MAX. t- zm.am /8'' MAX. z" ¢Ornm ALL -MOUNT SECTION EILING/INSIDE MOUNT SECTION BUILD -OUT MOUNT SECTION BUILD -OUT MOUNT SECTION a C .SCALE: 3'• = 1._0., SCALE: 3" = 1._0,. : OSCALE: 3" = 1._0.. - OSCALE: 3" = 1'-0" ��mmm, B 0z o �' 3.. 1 z EXISTING CONCRETE, MASONRY - of<r o -1/2' -1/2' .4" x 1/8 6063-T6 ALUM. a- 00 OR WOOD STRUCTURE. SEE EXISTING CONCRETE, MASONRY -CONTINUOUS .PLATE W/ 0 ul U. °0 ANCHOR SCHEDULE, TYP. OR WOOD STRUCTURE. SEE. = a SCHEDULE, THREE 1/4"0 WOOD LAG . . rF C3 CONNECTION TYPE. TRUSSORRAFTER SCREWS.WITH 2-3/4" a a ANCHOR CH ULE, TYP a REFERENCE. ANCHOR ER A~ .MINIMUM THREADED SCHEDULE FOR MAX. r• (1a.24 MAX. O.C.. 0 N �'1 C1 CONNECTION TYPE ❑ PENETR.. "T" IN WOOD (al U EMB SPACING BUT DO -NOT - REFERENCE ANCHOR EXISTING WOOD OR Q� EACH RAFTER OF TRUSS, ❑ M EXCEED.6" SPACING 1/4-20.MACHINE BOLT W/ ' E B ' a3 SCHEDULE FOR MAX.. STUCCO FINISH MW 24" O.C. MAX: WHERE NUT 12" O.C. (TYP., TOP SPACING MATERIAL BEYOND LAST TRUSS, ea; 1/2CONT. 11 CONT. & T P .12") * ` I I'I' � . =Z PLATE EXTENDS t9 2@TYP. TOP &.BOTTOM - E XT I:VICH 1/2 5/8 ROLLER ASSEMBLY. 1 W '�r. 1/2" ?� EXTEND.PLAT. TONE J.IUIEZ .: O 1/ 2 ". }" _ T R R FESSIo NGINEER TYP. EVERY OTHER PTN o TRUSS. P - _ .,FL•lJceos o:P 0010983 CIOTWO 1/G-20 w ❑ r. . MACHINE BOLTS O' } 1/4" MAX. #14 SMS 2.4" MAX: ((�� 1/2". MAX. .c ...,. W/ NUT OR #14 OECT MAX.IN V TEK SCREW.@ 12" O.C. 1/4' MAX. BETWEEN TRUSSES Z � z. Z� . (TYP., TOP &BOTTOM) z za NSEE TABLE 2 ww dm SEE TABLE 2 : na N J 8O �m o GLASS F tnQ.. � < 3a 03. OR DOOR ¢ o . 0f- 3 �7 9-3/16" MAX. IS o � ~ t-:� ' N .. ,: .. Q _JJ U q F JJ .. p QJ F c R DOOR O " ALT. ANGLE LEG DIRECTLON. �a Qp pap a REVERSED ANGLE LEG.MAY .: XtnW. 2 Xp. V Xo " . . Y E04 .. IYIP o BE FROM ONE ANGLE OR FROM F X= Il 2-7/8' ' Q='io (ul SEE TABLE 2 Q BOTH ANGLES (TYP.).. <u w� F O MAX. X zu X i ..-Cl CONNECTION TYPE a Wtn e : Z REFERENCE ANCHOR i w. Q N N Y w4... SCHEDULE FOR MAX. 1/4" 1/4,r MAX. y 0 SPACING BUT 00. NOT 0 0 EXCEED _6" SPA NG O.. ~ za. 1/4" MAX.: 16 a ; ' 0 11 CONT. 1/2 n w' �:, . PRODUCT REVISE D, o L1 ` x 1 / 2 " 1 / 2 " w o k - its com . m with the, El9rid>a 1/2 EMBED.. C3 CONNECTION TYPE iIIY g e O _ REFERENCE. ANCHOR �eidIng.Cotic'SCHEDULr 11 CONT. 11 CONT. ` Cl CONNECTION TYPE SPACING. E FOR MAX. AeeeptanceNo 03� REFERENCE ANCHORExpiration.®ate 0 08 EMBED. :``• . ' SCHEDULE FOR. MAX.' Idate c EMB. 10/17/2002 SPACING o_a,• '; BY . scale drawn by. E S/8"''MAX. 5/.B MAX. EXISTING CONCRETE, MASONRY Miami Da . ,roductControl. AS NOTED MCR NOTE: OR WOOD STRUCTURE. SEE: Q. EC.I. Division design by checked by BOTTOM MOUNT DETAIL ANCHOR SCHEDULE, TYP.. vJx I VJk . _ no. c - •- • MAY BE USED..AT TOP. drawing .. � •. WOOD SOFFIT/ O3-SO7 OBUILD-OUT MOUNT SECTION BUILD -;OUT. MOUNT SECTION FLOOR MOUNT SECTION . li E SCALE: 3,. 1. = ,0,. OSCALE: 3" = 1'-0.. OSCALE% 3" = T_0" sheet'3 of 7 05/05 03 .10:27 ' EXISTING -� STRUCTURE r �. 5/8""MAX. q R 6063-T6 ALUM. ANGLE TABLE 2'. . . EMSEE =� �DETAllS V1 w ;o • TWO 3/8"0 POWERS CALK -IN 3-3/4" O.C. �° W/ 1-1/4. MIN. EMBED. IN 3 KSI CONC. a n :�- 1-1/4' . THREE-1/4" O THRU BOLTS 1" MIN. DRILL 7/16"o HOLE' DRILL 5/16"� HOLE. �• r.r - h1 O v► °D Z E \ ALUM: BEAM (SEE BEAM 3.75" .WITH 4-1/2" MIN, ' Tw SCHEDULE BELOW FOR. EDGE DIST. OR FOUR i 1/4"0 ELCO CRETE-FLEXN BEAM DESCRIPTION & o o a a ca/1 3" O.C. W/ 1-3/4" MAX. HORIZONTAL SPANSY. F EMBEOMENT. & 2-.1'/2" _ Tf o I 4;A EDGE DIST. IN EACH 1/4=20 S.S. MACHINE SCREW ANGLE & NUT P 12" O.C. USE THRU .> BOLT OR ACCESS O-LE AS ' SHOWN IN DETAIL J 1.so" 1.12^ 1.ae" 1.aa" 1.1r' L'.. C 1/4" MAX'. Y/4" MAX. 3.Oo' 6.00: 2y - 1/2" 1 is Q oSJ 3 m -- n t` f ALT. LEG �. EowF w C . DIRECTION QWWF3 . 'ANGLE DETAIL USING CALMN ANCHOR I ' O.C. R FASTENING 1/4 20 S.S. MACHINE SCREW &NUT w m�N=o Vl EMBED ((�� 12" O.0 PROVIDE T'0 ACCESS HOLE in tnJ SCALE : 3"= r- 0" BACK E FOR f" [n SEE TABLE 2 �. J�-XQ W= PLYWOOD AND TWO 1/4"0 S.S. LAG SCREW (� LL. ORADOOR (A <I— y< STUCCO -FINISH 24" O.C. MAX. W/ 1-3/4 PENTR. 2 DRILL 5/16 .0 ` 8 . Wpp-a. 5/8" MAX IN CENTER OF STUDS' ALUM. BEAM & SHUTTER SCHEDULE DESCRIPTION SHUTTER SPAN. . BEAM SPAN 2 x 5' 8,-0,. 8.-1" Tw = .125" Tf=..125" , 10'-0" 7'-6" 2" x 8" .5''-0" 14'-0" 8'-0" 11'-6" Tw = .072":. Tf = :224" 10'-0". 10'-4" 2" x 9" 5'_0.. 15'-s" 8'-0" 12'-5" Tw = :072" Tf =_224" 10'-0" X w= to . HOLE I,00" 3.00" 3.001 3.00" 1.00" 4 in 0 1" x. 3" x 1/8" OR w. LL ...'- 1" x 4" x 1/8". c c 60637T6 ALUM. TUBE s V' Uz N ma2 V z Z z F 0 m y v; >nF aQtl (� Fv o ao..� 0 `n 0�J:,J H I _O U; ova ',z 0 W ch • N N o. E m '•Q W .W L"A o 1=•. W Z = '� V W Z T. Z ZW. � LL w Y m U O �. .N 0 Q UJ Z a N N Z ul IV> > , .�. rs. J W'^ Z z Z o+ a $ Li '17 O O Ys 1819 0 0 (MAX. DESIGN LOAD 72 PSF) {MAX. DESIGN LOAD* 72 PSF) $ OTOP S PU PORT BEAM DETAIL N 2 OWALL MOUNT SECTION -USING ALUM: TUBE z ° H SCALE: 3" = 1._0.. 1.50 I. SCALE: 3.. = 1._0.. _ Wa . E_ 2.50" 3.00" 3.00' S0" m 3. or EXISTING CONCRETE, MASONRY 11.00" OR.WOOD STRUCTURE. SE r y vo ANCHOR SCHEDULE,•TYP. c1NN. NOTE: 1. USE BEA SCHE ULE FOR � _ O N F_mal DETAILS �H ANDg. ECI. EQ. y 0 4%1` .' W GJtn lq . 2. SHUTTER SPAN TO BE LIMITED z u-mm TO THOSE SHOWN IN TABLE, SHEET 5. ' ANGLE DETAIL USING CRETE-FLEX ANCHOR . m 5/s •MAX. ' It u V2 C4 CONNECTION TYPE 3,. BEAM SPAN SHALL BE CONSIDERED O' w REFERENCE ANCHOR [°n❑ru AS THE DISTANCE FROM 4;OF SUPPORT' SCALE 3'= r- 0 �- TO f} OF SUPPORT. : �r` SPACING SCHEDULE FOR MAX. F. U1/4" "a 1 MAX. 0 " Z c SEE TABLE 2 0 wam: q GL SS OR DOOR. SEE TABLE 2 Q Wcf J OR DOO ORADOOR r W3� V.J. KNE , °=r FW—w. ❑w R SEE TABLE 2 3/16"W POP RIVET W .�- OR #12 TEK SCREW 8 = ZOW JJ R. PR ENGINEER. RLkenseN 010983 w==p3 °O 6., O.C. (TYP.) °°' to Q Jp 8 NN� p O & 5a X in J = jWHQZ.: ilk.: • 8 = to ASSEMBLY a .X=.-' Fu �. r' OR1#12 TEK RIVET 3/ 66 pp C X. W�o�� f Q' g in 3/16"� POP RIVE T .. C� 6" O.C. _ . p Q I� I C4 CONNECTION TYPE @ 6' C. (TYP.1 1/4" O MAX. TWO 3/8"W POWERS mE ;fir 1_1j4~ w , REFERENCE ANCHOR E FOR MAX.. D CALK -IN �a1 3-3/4" O.C. " W/ 1=1/4 . MIN. EMBED. AS�EMBL Q 3/16"0 POP RIVET a \ �1 - SPAC NG co IN 3 KSI CONC. WITH 4-1/2 MIN.'. a r & 5 OR. 0'R #12 TEK SCREW` @ 6" O.C.. 1/4"o? I o p EDGE DIST. OR FOUR. 1/4"0 ELCO CRETE-FLEX [ a AL. BEAM (SEE BEAM SCHEDULE ABOVE FOR _,. MAX.' EQ. OPTIONAL LOCATION EO.. in r Z u. o u) �n1 3" O.C. W/ 7-3/4" EMBEDMENT & 2=1/2": DETAILS . Tf '1/2" BEAM. DESCRIPTION &>t CS CONNECTION TYPE. REFERENCE ANCHOR • DGE DIS o ti z . B . O 0 EDGE DIST. IN EACH _ V1 & I O ©' MAX. HORIZONTAL'SP 4N5) $_;; 3 . ,_ ..,. SCHEDULE FOR MAX N - p ANGLE ^s 1/4-20 S.S. MACHINE SCREW & zF ' I - •' .SPACING '' CEILING/INSIDE MOUNT SECTION d , . „. Tw i" MIN. 3% ACCESS A S HOLE IN BOTDTOM OF " E MBED. ', FOR WOOD PLATE USE 1/.4"W OSCA SCALE. 1• 0" S.S: LAG SCREW. W/ 1-3/4" _ - ti a 3 Q . o' 9 _ (� ACCES :.; BEAM OR USE THRU BOLT AS PENETRATION INTO WOOD HOLE : SHOWN IN DETAIL H r fit:! N E ER(alA TI0 . • {# PLAT 12 0 C PRODUCT RE�IS�D. '. . H Zp 3' 6 ALU TW0 1/4"0. S.S.LAG SCREW as somplyirtg.dYit hQhsFlorida o _ m 606X3-T M. ANGLE PLYWOOD AND (al 24" O:C.IMAX: W/ 1-3/4" P PENETRATION Baidnng t'0de . date THREE'-1/4"O THRU BOLTS STUCCO. C0 !N CENTER OF STUDS- . r 0 b.1 Acceptapceaeip p J . 10/17/2002 . - EXISTING STRUCTURE . S/8".-'. MAX • ALT. LEG.DIRECTION 5 81'SMAX. .. 2." x 6" P.T. EXpIFat10R Dated g scale' drawn by ' q5 NOTED MCR WOOD PLATE desi9nWK che[kev K * (MAX. DESIGN LOAD 72 PSF) (MAX. DESIGN LOAD = 72 PSF) t1/liai 1)a roduct Control . p1Y1S n . drawing no. '- BOTTOM SUPPORT BEAM DETAIL -SCALE: WALL MOUNT SECT fON-USING.2" x 6" P.T: WOOD PLATE pp SO3i-4 of 7 SCALE: 3" = 1'-0" 3" =X-0" - O O. In M • o " M ' .O .. .. O to Lo 0 c 0 CJ 3 to o I n O . 00 M N I . n o ' I to O U u j 0 0 E ti 05/05/03 • 10:27 . ANCHOR SCHEDULE " FASTENER MAXIMUM. SPACING (INCHES) REQUIRED FOR VARIOUS DESIGN LOADS AND SPANS LOAD MIN. 2n EDGE DISTANCE MIN. 3" EDGE DISTANCE (W) SPANS UP TO SPANS UP 70. SPANS UP TO ANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO. SPANS UP TO F,. P.S.F. 5'-B„ 8'-0'' 9,_ �` J31 V 5 -8 8' 13.-V' ANCHOR TYPE MAX. (SEE NOTE 1.) (SEE NOTE 1) (SEE NOTE 1) (SEE NOTE 1) (SEE NOTE 7) (SEE NOTE 1) (SEE NOTE 1) ' y .(SEE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE ' NOTE (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) . 1) Cl t2 C3IC.4 CS C1. C2 C3 C4 C5 Cl C2 C3 C4 C5 Cl( C2. C4 C5 C1 CZ C3 C4 C5 C1 C2 C3 C4 C5 C1 C2 C3 C4 C5 . C1' C2-C3 C4 C5 45.0 12 .12 12 12 7 12 12 12 8 5 12 12 12 '7' 4 10 5 .5 5 3. 12 12 .12 12 9 12 12 12 10 6 12 12 1Z 9 5 11 6 6 6 3 57.0 12 12 12 9 6 12 12 12 6 4 11 9 10 6 3 8P 3- 4 12 12 1.2' 11 .7 12 12 12 8 5 12 10 12 7 4 9 3 3 5 3 20 12 12 12 .7 4 10 5 5' S 3 9 4. 3 4 8 3 4Al2 12 12. 9 5 11 6 .36 6 6 4 10 4 4' S 3 9 3 3 5 3 /k" bITW+TAPON W/ T `_V''MIN. EMBEDMENT 105.0 -10 5 5 5 3 8 3 4 8 3' 4 8. 3 411 6 6' 6 3 9 3 3 5 3 9 33'' 393( IN.3,100 P.S.I. CO ) 170.0 8 3 . 4 8 3 4 B 3 4 8 3 49 3 3 5 3 9 3 9 3' 3 5 31.1 3 3 5 3 45.0 12 12- 12 12 9 12 12 '.12 9. 6 12 12 1.2 8 6 12 9 9 5 4 :12 12 12 12 12 12 12, 12 12 10 12 12112 12 '9 121.111 11 9 .6 57.0 12. 12 12 10 7 12 12 12 .7. 5 12 12 '12 6 4 12 5 4 4 3 12 12 12 12 11 12 12 :12 12 8 12 12 12 10 7 12 6 6 7 5 .1/4"0 POWERS CALK -IN . W/ 7/8" EMBEDMENT 73.0 12 12 12 8. 5 12 9 9 5 4 12 . 6 6 5 3 -12 5. 4 4 3 12 12 12' 12 8 12 12' 11 9 6 12 8 8 6 5 .12 6 6 7 5 & 1/4-20 STAINLESS STEEL MACHINE SCREW 105.0 12 9 8 5 4 12 5 4 -4. 3. 12 5 4 4 3 12 5 4 4 3 12 11 11 9 6 12 6 6 7 5 12 6 6 7 5 12 6 6 7 5 (MIN. 3,000 P.S.I. CONCRETE) 1.7 0.0 12 5 4 4 3 12 5 4 4- 3 12 5 4 4 3. 12 5 4 4- 3 12' 6 6 7 5 12 6 6 7' 5 12 6 6 7' 5 12 6 6 7 5 45.0 12 12 12 10 6 12 12 12 7 4 12 12 12 5- :4 8 4 4 4 12 12 12 12 7 12 12 12 9 5 12 12112 8 4 .9 5. 5 5 ' 3 -� 57,0. 12 12 12 8 5 10 10 10 '5 3 9 7 8 5 3 6 3 12 12 12 10 6 12 12 12 7 4 10 '8 -9 6 3 7 4 ' 1/4"0 POWERS ZAMAC 73.0 11 11 11 6 3 8 4 4 4 7 3 3 4 6: 3 12 12 12' 7 4 9 5 5 5 3 8 3 3 4 7 4 NAIL -IN W/ 1-1/8" MIN. EMBEDMENT 105.0 8 4 4' 4- 6 3 6 3 fi 3 9 5 4 5 3. 7' 4 7 4 7 4 Z(MIN.3.0 I EOGLCRETI7 170.0 6 3 6 3 6 3 6 3 7 4 7 4 7 4. 7 4 45.0 12 12 1-2 12 11 12 12 12 12 7 12 12 12 11 6 12 8 7 7 4 12 12,12 12 12 12 12 12 12 8 '12 1Z 12 12 7 12 8 s 8 .5 1/_4 0-ELCO 57.0 12 12 12 12 8 12 12 12 9 6' 12 12112 8 5 11 .4 4 6. 3 12 12 12 12 9 12 12.12 11 6 12 12 12 10 6 12 4 4 7 4 MALE/r - F PANELMATE') 73.0 12' 12 T2 10 6 12 8 8 7.- 4 12 5 5 6 4 11 1.4 4 6 3 12- 12 12 12- 7 -ALE ,/ EMBEDM 12 8. 8 8. . 5 12 6 5 7 4 12 4 4 7 4 -T MIN. �& 1/4=2o MA E 165.0 12 7 7 7 4 11 4 4 6 3 11 4 4 6. 3 11. 4 4 6 3. 12 B. 7. 8". 5. 12 .4 4: 7. 4 `12 4 4 7 4 12 •4 4, 7 4 NUT (MIN. 3,300 P.S.I. CONCRETE)' 170.0 11 4 4- 6- 3. 11 .4 4 6 3 11 -4 ' 4 ''6 3 11 4 4 6 3 12 - 4.. .'4 7.. 4 12 .4' 4 7 4 12 4 4 7 4 12 4 : 4. .7 4 45.0 12 12 12 12 .11 12 12 12 12 7 12 12 12' 11 7 12 S. 6 7 4 12'. 12 12 12 12 12 12 12 12 9. 12 12. 12 12 8 12 10 -10 9 6 57,0 12 12 12 12 8 12 12 12 9 6 12 12 12 8 5 12 4: 4 6 3 12 12 "12 12' 11 12 12112 12 �7 12 12 12 10 7 12 6 .5. 7 4 1/4" ELCO mTEXTRON 73.0 12 12 12 10 6 12 8 8 7 4 12 6 5 6 4 12 4 4 6 . 3 12 12 12 12 8 . 12 11 10 9_. .6 12 7 ' 7 8 5 12' 6 5- 7 HEX-FLANGETAPCON/ HEX HEAD TAPCON W/ 1-3/4" EMBED 105.0 12 8 8 7 4' 12 4 4 . 6- 3 12 -4 4- 6 . -3 12 4 4 6 3 12 10.:10 9 6 12 6' 5 -7 4 12 .6 5, . 7 4 .12 '6 ..5 7. 4 (MIN. 3,320 P.S.I. CONCRETE) 170.0 12 4 4 6 3 12 4 4 6• -3 12 4 4 6 3 12 4 4 6 3 12 6 5 7 4 12 6 5 7 4 12 6 5 7 4 12 6 5 7 4 45.0 12 12 12 12 .11 12 12 12 12 7 12 12. 12 11 7. 12 8 B 7, 4 12 12 12 12 12 12 12 12 12 9' 12 12 12 .12,1' 12 10 10 9 6 57.0 12 12 12 12 8 12 12 12 9 6 12 12 12' 8 .5 12 4 4 6 '3 12 12 12 12 11 12 12 12 12 7 12 12 92. 10 7 12 6 5. 7 4 1/4"0 ELCO CRETE FLEX 73.0 12 12 12 16 6 12 8 6 7 4- 6 5 6 4 12 4 4 6' 3 12 12 12 12 8 12 11 10 9. 6 12 7 7 S. 5 12 6 5 7 4 W/ 1-3/4" MIN. . EMBEDMENT :12 . . 105.0. 12 .8- 8 7 4. 12 4 4 6. 3 12 4 '4 .6. 3 12 4 .4 6 3 12 10 '10. 9 6 12 '.6 5' 7 4 12 6 .5' .7 4 12 6 5 T. 4 (MIN. 3.350 P.S.I. CONCRETE) . 170.0 12 -4 4 6 3 12 . 4 4 '6'. 3 12 4 4 6 3 :12 4 4 6. 3 12 6 5 7 4 12 6. 5 7= 4 12 6 5. 7 4 12 6 5. 7 4 ANCHOR. SCHEDULE FASTENER MAXIMUM SPACING (INCHES) REQUIRED FOR VARIOUS DESIGN LOADS AND SPANS LOAo MIN. 3/4e EDGE DISTANCE U (W) SPANS UP TO SPANS UP TO SPANS UP.TO _ -PANS-UP-.T_ . P.S.F. 5'-B'_' l-,13 N ANCHOR TYPE MAX. (SEE NOTE 1) (SEE NOTE 1) (SEE NOTE 1)' H (SEE CONNECTION TYPE 'CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE !� NOTE (SEE NOTE 3) . (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) 1) C1 C2 C3 C4 CS C1 C2 I C3'1 C4 I CS C1 C2 C3 C4 C5 C1 ' 3. C 41 C5 45.0 121.12 12 9 7 12 '12 12. 6- 5 12 '12 12 - S. . 4 12 9 9 -3 3 57.0 12112 12 7 5 12 12 12 S 3 12 12 12 4 3 12 : �5- '[, 3 O O 1/4"0 W000 LAG W -t--3/, k'LMIN. THRE 73.0 12 12 12 5 4 12 9 9 3 3 12 6: 6. 3 12 5 4 3 PENETRATION-S £AR PARALLEL'0 ERP 105,.0 12 9 8 3 3 12 5 4 3. 12 5 4 3 12 5 .4 3 TO WOO RAIN 17D.0 12 5 4 3 12 .5 . 4 3 12 5 4 3 12 5 4 3 t7 �z r� nNio� u z Z Z_ . ^ J. 2 VI W. LL Q U W oaf H� p Q _O gLL Q 0 SNP Co Lnn. o• N W' m 2 V U ao. LU ll 0 o � Co c W c 2 m ® U J uj � p Y0O W U z ° �_ _ N valto a:zm�� F II LL O aarnm X. .- 0 N oaa 10uJ.U)rn �Q. . 0 �w-1 CL x a O .� p O VJ. KNEZEVICH - PROFESSIONAL ENGINEER ' FL licence Nw P 10983 Y v E , ANCHOR SCHEDULE FASTENER MAXIMUM SPACING (INCHES) REQUIRED • • VARIOUS DESIGN LOADSAND SPANS • +MIN. 2" EDGE DISTANCE —ter MIN. 3" EDGE DISTANCE SPANS UP • • • . • • • • • • • _ • • UZ m o � Z Z Z F, m � 3 Y_ W lnr o � Qo g� N a � J O � , �� W m VI W. W Q � > W. W � N � Y m O 2$ Wgz O NuJ in W Z. m @ U � Z O E Wu�z ui �a�e Wmmm � 7 ,- � Wmvm Q<NN . ^ .7 _'. FOAOI z �uJ.m� Y.. LL C Na}W-LL . � 7 I�0 z. U~ a N 0 u rV� o C� ". --co .ANCHOR NOTES: ' :'... 3 « : • N .. 1.. SPANS ANDLOADS SHOWN HERE ARE FOR DETERMINING ANCHOR SPACING ONLY.. ;, Y O ALLOWABLE STORM NUTTER. SPANS FOR SPECIFIC LOADS MUST BE LIMITED TO THOSE WHERE LAG SCREWS FASTEN TO NARROW FACE F .. SHOWN IN TABLE 1,-PAGE 5, E O -SFASTENER'a ? ; _ to f SHALL BE LOCATED IN CENTER OF NOMINAL 2 x 4 (MIN.) WOOD SD. 3" o O 2..'. ENTER ANCHOR -SCHEDULE BASED ON THE EXISTING STRUCTURE MATERIAL, EDGE DISTANCE IS ACCEPTABLE FOR WOOD FRAMING. WOOD STUD SHALL BE - ANCHOR TYPE AND EDGE DISTANCE. SELECT DESIGN LOAD GREATER THAN OR "SOUTHERN PINE" G=0.55 OR GREATER DENSITY. LAG.SCREWS SHALL. -HAVE o EQUAL TO NEGATIVE DELOAD ON SHUTTER AND SELECT SPAN,GREATER PJAILLIPS. PAN HEAD OR HEX�HEAD.. THAN OR.E.QUAL .O. SPAN.. .8. MACHINE SCREWS SHALL HAVE MINIMUM OF 1/2" ENGAGEMENT OF THREADS IN. .3. EXISTING. STRUCTURE HAY BE CONCRETE HOLLOW BLOCK OR WOOD -FRAMING. BASE ANCHOR AND MAY HAVE EITHER. -A PAN HEAD, TRUSS HEAD,. OR WAFER 0 N REFERENCE ANCHOR SCHEDULE FOR PROPER. ANCHOR TYPE BASED ON TYPE OF HEAD {SIDEWALK BOLT), U.O.N. EXISTING STRUCTURE AND APPROPRIATE CONNECTION TYPE. SEE MOUNTING SECTION DETAILS FOR IDENTIFICATION OF CONNECTION 'TYPE.. 9., NATES ANChiOR'COND 'CONDITIONS RICH ARE NOT: ACCEPTABLE USES.' G I W P U ascon: 1 'n withtleBFlprjda. p Coif darn :. 10/17/2002 ®DESI Brmiding e � 4. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' " " Acceptance No 03 -' 0'6 ! 6:: of ' o. RECOMMENDATIONS. 10• �Y DESIGNATES .ANCHORS WHICH ARE REMOVABLE BY. REMOVING MACHINE SCREW, NUT OR..WASHERED WINGNUT, E;�pj tj0 DateO ' •O pOB scale drawn 6y 5. MINIMUM EMBEDMENT AND EDGE DI STANCE -EXCLUDES WALL FINISH OR STUCCO.. nsNOTEo ncR E 0 "- c 6. WHERE EXISTING STRUCTURE !S WOOD. FRAMING WOOD FRAMING CONDITIONS VARY. FIELD VERIFY THAT FASTENERS ARE INTb ADEQUATE WOOD FRAMING.' 11. FOR BUILD'' -OUT MOUNT SECTION D ANCHOR SPACING'SHALL NOT EXCEED 8=1O.C. , O $' Y MiamjDad rpductCoatioi design by checked by vex vex MEMBERS, NOT PLYWOOD. FASTENING TO PLYWOOD IS ACCEPTABLE ONLY FOR . 12• FO.R BUILD-0'UT MOUNT SECTION EO ANCHOR SPACING SHALL NOT. EXCEED ' Divisjott drewlny no. SIDE CLOSURE PIECES.. 6" O.C. . 03-807 sheet 7 of 7 . .. ' 05/05/,•.03 .: 10: 27 .. "