HomeMy WebLinkAboutSUBMITTED PAPERSDate. I Fee Due:
J o a�rO Receipt#
Permit # 0'&-- (8
'PD�St. Lucie. County Building & Zoning.Department -c 23700 Virginia -Avenue
• = Fort. (�
Pierce,
FL_ 34982 �C,�N�
OR1 462 1553 �,t `UC%�Y
APPLICATION FOR REPLACEMENT OF CO1117ty
WINDOWS, SKYLIGHTS, DOORS & OVERHEAD .GARAGE DOORS:
LOCATION/SITE ADDRESS: ?j 1 6b j\h . A 1 A- : - P-
<< SECT I I TWP RNGoE MAP �/ NG —
PARCEL ID NUMBER: 14125 .. fo06 6)D(p4 — nvr)
i. DESCRIPTION OF PROJECT OR WORK ACTIVITY: Ep_80 � � ��
S.G - boo a-S
TYPE OF STRUCTURE: ❑ .SFR 4''..OTHER , . (JQ h) j aW L A11 U (n
OWNER INFORMATION 6. CONTRACTOR INFORMATION
Name: po%g 6 • S564LIS aW FL Reg/Cert #:
Addressl. Un t� p , A J A County Cert#:
City: State: L • . Business Name: 1:1-D91BA Awluii;t6iA
Zip: Phone: 7i2`�{fo� ��3%. Phone))2 Moo Fax - -77a-
'roduct Table 1606.2B
* 15' maximum height
Minimum Design
Pressure
Design -
Pressures
0:-70
'Manufacture
. P -. �T ��.,S .
Model
Number
73 O
NOTICE OF ACCEPTANCE #
FLORIDA #
No— d sa3• 0 3
130 mph
140 mph
iv auuvna.ac
Exposure..0 ** I 49.2. 57:1� = I I
awing & Garage. Doors
Ex osure--B 38 44
Ex osure C ** 45.9 53.2.
VALUE OF CONSTRUCTION:. $,. T, (�- +Ob
NNER'S AFFIDAVIT: I certify that all of the information contained. in this application is ect and th all work will:be done in
compliance with all applicable laws regulating const trn and o ng. i
C�WAXt Scott THOWSonl
PRINT QUALIFIERS/OWNERS NAME SIGN OF A 1FIER/ ER
STATE OF FLORIDA, COUNTY OF S%L(0d/E OWLE BEFORE ME THIS DAY OF
I I tT, 20 77 BY CIW PA) JS2M "'(R W WHO ERSONALLY KNOWN ME OR WHO HAS PRODUCED - -
AS IDENTIFICATION.
��""""°�� MAUREEN J. AL�jLQ��
SIGNATU O NOTARY TYPE OR PRINT NAME OF NOTAR MY COMMISSION #D19ilt8dl9
n� FJPIRB: September 03, 2010
TITLE: NOTARY PU COMMISSION NUMBER i�a�a•xaraav F9•NaaryDsaowtAtsoc Co.
Window. Skylight, Doors. Garage Door permit application 7/18/05 dmR
w
NOTICE TO OWNER: YOUR FAILURE TO -RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
-TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
❑ Attach 2 eopies of the N0A�oi.'F1oiida approval With details'to the product being used
INSTRUCTIONS
Please complete all information in the.space provided. All information must be Printed (useblack or blue ink only) or Typed.
This application for replacement of Windows, Skylights, Doors &Overhead doorstto be used for only those -activities that. are not otherwise
included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of
structural alteratii q.. 3uildingiactivities,involving__structural-alteration,.in addition to the replacement of Windows; _Skylights, Doors &
Overhead doors; must be permitted through the regular building permit review process. The information to lie provided with this application
,f
includes:
1. LOCATION/SITE ADDRESS: ................................... `,Indicate the, street address, or general location, of the property on
which ilie-luilding activity is taking'place.
2. PARCEL ID NUMBER: ...... ...... .............. ....................... Indicate the Property Tax Identification Number forthe property -on
which the building activity is.tal ing place.
3. DESCRIPTION OF PROJECTOR WORK, ACTIVITY........ Briefly describe the building activity under permit application-
4: ,,: OWIJERS INFORMATION;.......... :.....:.::............................. Indicate the name and address of the owner of the property on which
` the product is to be insfalled: '
5. CONTRACTORS INFORMAT.ION:...................:... Indicate the State of 1760&(if applicable). and St. Lucie '
contractors registration numbers, and the name of the business doing
the work.'
6. VALUE OF CONSTRUCTION :..:.....:::............. ' ; : Indicate.,the-total'walue' 4the-work to take place. Total cost of
construction includes all material and labor costs associated With the .
building/construction activity. The value of construction is. used to
determine the amount of permitting fees to be assessed. St: Lucie• ..
County reserves the right -to question and/or modify_ the. indicated
value of construction if it is demonstrated that.the`subniitted figures. -.
are not consistent with similar types of construction:
All applications for Permits are to. besubmitted to the St. Lucie County Building and Zoning Department; St. Lucie County Administration .
Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for'Permits must be complete and. filed with the Department no
later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M: For assistance in completing this
application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553; during regular office hours (8:00 AM
- 5:00 PM), Monday through. Friday.
Following the issuance of this Windows, Skylights, Doors & Overhead,do_ors replacement Permit, the scheduling of all required inspections
may be made by calling (772) 462-1261. -
SLCCDV FORM NO: 006-05
Window, Skylight, Doors, Garage Door permit application 7/18/05 dmg
f
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
hftp://stlucieco.gov/ce
BUILDING PERMIT
Page 1
Issued: 05/24/2007 Conf #; 545 Permit #: SLC- 0705-0387
Job Location: 3100 Al 405 City: FORT PIERCE
Permit Type: Building (Miscellaneous)
Job Description: REPLACE SLIDING GLASS DOORS TO IMPACT SLIDING GLASS DOORS FOR A CONDOMINIUM
Subdiv: Sands on the Ocean Section 1 - Condo
Lot: Block: Parcel: 1425-606-0009-000/1
Contractor THOMPSON EDWARD S T/A FL AWNING GLASS & SCREENIN, (772) 461-8500
480 SOUTH MARTKET AVE FT PIERCE, FL 34982
Property Owner POLLY E JOHNSON (TR) (772) 467-9437
HILLSIDE FARM 257 DAVIS RD CAVENDISH, VT 05153
Setbacks Left: Right: Front: Rear: Zoning: HIRD
Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00
Minimum Floor Elevation: Flood Map: Flood Zone: Elev:
Job Value: $15,000.00
Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code
including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all
requirements of the 2004 Florida Building Code.
NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the
records of this County, and there may be additional permits required from other governmental entities such as water management districts, state
agencies, or federal agencies. s:553.79(10), F.S.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S.
Christopher Lestrange
Building Official Date
For Automated Inspections, Call (772) 462-1261
For Questions, Call (772) 462-2172
St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and
become null and void if work authorized by such Building Permit is not commenced, having called for and
received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the
work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date
of issuance of the Building Permit.
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
http://stfucleco.gov/ce
Date: 24 May 2007
Job Address: 3100 AlA 405
Received By: spellsv
Paid With: CK
Paid By: FLORIDA AWNING & GLASS
Building �
Receipt
Sign:
Receipt#: 0000054391
ermit Number: SLC- 0705-0387
Amount: $130.00
'redit Card Number:
Check Number: 48962
EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY .
FILE # 3059457 OR i K 2822 PAGE 2016, Recorded 05/24/2C�--Yat 11:17 AM
Permit No.
State OfTF:Iy P-tDA
NO11C'E OF COMMENCEMENT
'rac.iDi 111A5— (006-0009-000—)
Count l Of
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter
713, Florida Statutes, the following information is provided in this Notice of Comtnenc�ment.
and street address, if
General description of improvements .=rAAAQ.3 -sL ti11N&, G1At�boy2S
Owner jM4
E..3r)f4NS0
1V
Address1{lµtt e� FA�run �s� �.ilC RA� �►�__�T' o srs 3
Owner's interest in site of improvement _
Fee Simple Titleholder (if other than owner)
Address
Contractor R oa,m kF IJ SU d T1 UYY s 0) Phone # 17a - 01- 450
Address49D Si,- spate ET a R" At • 16 _ft- il=6. 24A f2 Fax # 77a" bbh jV Q-
Surety _
Address
Amount
Phone #
Fax #
Lender _ - — _ Phone _
Address Fax #
Penns within the State of Florida designated by Owner upon whom notices or ether documents may be served ti provided by
Section 713.13 (1) (a) 7., Florida Statutes:
Name_ _ ___ _�_ Phone #
Address Fax#
In addition to himself, owner designates of - (Phone #
Fax # ) to:'eceive a copy of the Lienoes Plotlee as provided in Sectitm 71 • .I3(1)(b}, Florida Statutes.
Expiration date of notice of commencement is one year from the date of recording unl ss a different date is spec: fled.
(Date)
OK S SIGN RE
STATE OF FLORIDA. COUNTY OF _ST .to .0 E
Aclmowledged before me thiseaZ-, day of _ _M[[}n, who ' ersonally known me of
who has produced ^ uts r entification. 1 .
(seat) SIGN TURF O *IOTAR
-YP 1 OR PRINT NAME OF NOTARY
THISTO CERT-1- = T{,f , '"1S I A
:.v T `tli)r f OFTHIb
TRUE AND{;*,,i
®RIG Vy
C EI3.. Uw .WLEiA_v0 T
iiO TARP PUBLIC. 'SITLE
_ _COMMISSION MWER
MAL►REEN I. ALLEN
g d MY COMMISS(ONNDDr86819
?wM' ����tmba 07, Y010
lacalt+ocVty ftNanyDirpet�roc Cn
Property Appraiser - St.Lucie County, FL
Page 1 of 1
--e;
PROPERTY RECORD CARD
Polly E Johnson (TR) Record: 1 of 1
<<Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print
Property Identification
C�Gy
Site Address: 3100 N A1A
ParcellD: 1425-606-0009-000-1
\���UCIF
e
Secrrown/Range: 25 :34S :40E
Account #: 8877
Map ID: 14/25S
Land Use: Condo
d -
Zoning:
City/Cnty: ST. LUCIE COUNTY
Ownership and Mailing
Legal Description
Owner: Polly E Johnson (TR)
SANDS ON THE OCEAN -SECTION 1- UNIT 405 (OR
1371-325, 329)
Address: Hillside Farm 257 Davis Rd
Cavendish VT 05153
Sales Information
Assessment Final Total Land and Building
Date Price Code Deed
Book/Page 2006 Val: 310000 Land Value: 0 Acres: 0
3/2/2001 65000 04 WD
1371 / 0329 Assessed: 310000 Building Value: 810000
2/26/2001 65000 04 WD
1371 / 0325 Ag.Credit: 0 Finished Area: 1207 SgFt
2/17/1994 100 01 WD
0886 / 1901 Exempt: 0
11/1/1986 129900 00 CV
0523 / 0614 Taxable: 310000
TotalTax: 6206.26
BUILDING INFORMATION
A
Exterior Features
lm-agQ
2
vailable
3900
View:
Ocean
RoofCover:
-
RoofStruct:
-
View
ExtType:
X131 - SndOTOcnSc1
YearBlt:
1983
Frame:
-
Grade:
NT - NT
EffYrBit:
1983
PrimeWall:
-
StoryHght:
0010 - 1 Story
No.Units:
1
SecWall:
-
Interior Features
BedRooms:
2
Electric:
-
PrmintWall:
-
FullBath:
2
HeatType:
-
AvgHUFI:
STD
1/26ath:
0
HeatFuel:
-
Prm.Flors:
-
%A/C:
0
%Heated:
0
%Sprinkled:
0
Special Features and
Yard Items
Land Information
Type
Y/S Qty. Units
Qual. Cond.
YrBlt. No. Land Use
Type
Measure Depth
PUNT - PUD UNIT
S 1 310000
AV AV
0 1 0400-Condo
N -No Land Val
0 0
CLiv - CondoLivArea
S 1 1207
AV AV
0
THIS INFORMATION IS BELIEVED TO BE CORRECT AT
THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED.
http://www.paslc.org/prc.asp?prclid=142560600090001 5/24/2007
4 TV
. V
f Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1148
http://stiucieco.gov/ce
INSPECTION CARD
Permit #: SLC= 070_0387- — Conf #; 545 Type: Building (Miscellaneous)
Issued 05/24/2007 Double Fee: No
Job Location 3100 Al 405 City, FORT PIERCE
Jurisdiction: St. Lucie County Lot; Block:
Parcel: 1425-606-0009-000/1 Subdiv: Sands on the Ocean Section 1 - Condo
Owner: POLLY E JOHNSON (TR) Flood: Elev: Flood Map:
Project:
Job Description: REPLACE SLIDING GLASS DOORS TO IMPACT SLIDING GLASS DOORS FOR A
CONDOMINIUM
Contractor THOMPSON EDWARD S T/A FL AWNING GLASS & SCREENIN, (772) 461-8500
480 SOUTH MARTKET AVE FT PIERCE, FL 34982
Property Owner POLLY E JOHNSON (TR) (772) 467-9437
HILLSIDE FARM 257 DAVIS RD CAVENDISH, VT 05153
Setbacks Left; Right Front; Rear;
Inspection Notes: ALL INSPECTIONS WILL BE DONE BY SPECIAL INSPECTOR FRANK FARLEY
SUB -PERMITS
Permit # Status PT Cert # DBA Owner / Builder Job Description
INSPECTIONS - For Requests, Call: (772) 462-1261
Permit # Code Description Priori Date Sched. Res Description Inspector Date Insp.
0705-0387 133 Window/Door Bucks 1
0705-0387 148 Window/Door Attachment 1
0705-0387 994 Final Engineer Report 1
0705-0387 999 Final Inspection 1
0705-0387 999 Final Inspection 9
ReGONIS13
1,3L302001
Public Worl's
St. Lucie County,
FL
Permit Nur 0705-0387
FARLEY AND ASSOCIATES
Consulting Engineers, Inc.
7707 U.S. Highway 1, Suite #3, Vero Beach, Florida 32967
Frank W. Farley P.E. 40111 - E.B. 6641
(772) 589-6229 (772) 589-2296 fax
(321)984-9661 (321) 984-9599 fax
26 July 2007
St. Lucie County Building Department
Virginia Avenue
Ft. Pierce, Florida
Ref Window Sliding Glass Door Installation
The Sands Unit 405
Dear Sir:
As requested by the owner, Polly E. Johnson, the undersigned inspected the installation
of the sliding glass doors performed by Florida Awing and Glass at the subject residence.
The doors were installed as required by the manufacturer and this office to withstand the
design wind pressures required by the 2004 FBC with the 2006 Amendments.
Should you have any questions, please feel free to call.
I
secelveD
31J` 3 0 2007
Public Works
gt. Lucie County' Fl-
i
- L
FARLEY AND ASSOCIATES
Consulting Engineers, Inc.
7707 U.S. Highway 1, Suite #3, Vero Beach, Florida 32967
Frank W. Farley P.E. 40111 - E.B. 6641
' (772) 589-6229 (772) 589-2296 fax
(321)984-9661 - (321) 984-9599 fax
26 July 2007
St. Lucie County, Building Department
Virginia Avenue
Ft. Pierce, Florida
Ref: Window Sliding Glass Door Installation
The Sands Unit 405
Dear Sir:
As requested by the owner, Polly E. Johnson, the undersigned inspected the installation
of the sliding glass doors performed by Florida Awing and Glass at the subject residence.
The doors were installed as required by the manufacturer and this office to withstand the
design wind pressures required by the 2004 FBC with the 2006 Amendments.
Should you have any questions, please feel free to call.
Sincerely,
r, s
6 1.:'a
FRANK W. FARLEY P.E.
3388 Henderson Drive, Valkaria, Florida 32950
Frank W. Farley P.E. 40111
' (321) 984-9661 (321) 984-9599 fax
16 May 2007
St. Lucie County Building Department
2300 Virginia Avenue
Ft. Pierce, Florida 34982
Reference: Unit 405
The Sands Condominium
3100 N. AIA
Ft. Pierce, Florida 34949
Dear Sir:
The undersigned has been retained by the owner, Polly E. Johnson, to provide Special
Inspection Services (Threshold Inspection) for the replacement of the windows/exterior
doors for the referenced project.
The undersigned will inspect the work performed by the contractor and upon completion
will certify that the work was done in accordance with the permitted plans.
Should you have any questions, please feel free to call.
Sincerely,
Fr
PE 401
SI 8 !
ley FIL
c.s .E
Py
ST. LUCIE COUNTY
BUILDING DIVISION
REVIE7iNNSDP
DATE
MIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
MIAMM m
EMMFMi4MI DARE COUNTY, FLOR DA
METRO -DARE R AGLER BUILDING
BUII.DING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603
PRODUCT CONTROL DIMION MIAK FLORMA 33130-1563
.. v..�.J I.i �.)u. �YL .iy✓�✓.r"iiVV
NOTICE OF ACCEPTANCE MA) www.builfntrcodeonline com
PGT Industries, Inc.
1070 Technology Drive
Nokomis, FL 34275
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by Miami -Dade County Product Control
Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and
other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in auras other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHD may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA
reserves the right to revoke this acceptance,. if it is determined by Miami -Dade County Product Control
Division that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone_
DESCRIPTION: Series VOMW Aluminum Sliding Glass Doors — L.M.I.
APPROVAL DOCUMENT: Drawing No. 4406-1, titled "Alum. Sliding Glass Door, Impact", sheets 1
through 17 of 17, dated 4/15/05 with revision E dated 4/12106, prepared by manufacturer, signed and sealed
by Lucas Andrew Turner, P.E., bearing the Miami Dade County Product Control Revision stamp with the
Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division.
MIssILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the ananuf ichmes. name or logo, city, state and
following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the pmfbrmmw of kris product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture ofthe product or process. Misuse of this NOA as an -endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the wards Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. N any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 03-0526.05 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez, P.E.
AML NOA No 06-VM&03
Expiration Date: November 11, 2009
Approval Date: August 3, 2006
Page I
T-ff
90OZ `£ Vanv mm PAojddv
69K `TT JaquOMN -joQ uoumdzl
£O' ON VON
Jet
a (�Dd
d Ian�Ai22,
(LOn90-t0 # NONjapunP4nS)
'a-d `eP dwgjwl opunmpg Aq Palms Puv pouSrs to/SZ/£0 Pape
`651V-'M -oK podag wj, `oul `f towjogwj Suw-L uogs.gsauad,fq paaedoid `coop
ssgW Smpils mnumtnin us3o meiSetp notrp4sui pun sSumwp dn-po4wtu qjm Suole
b6-ZOZ SVJL Pug (q) I'Z'£ I It�Z jUA jod `: s%.L Anud poojod (9
WEOZ SV.L `mod .tad SmM I oinssajd putAA ogoA3 (s
b6-IOZ SV.L `Ogg jod Isa,L pvduiI alcssUN aawl (ti
t?6-ZOZ SvZ `jgd jad `miL oousr!sag jmsM (£
V6-ZOZ Sd.L `jgd jad SaipsoZ `uojL amssasd .qV ogeiS uuojiutl (Z
v6-ZOZ SVZ `3Sd Z uoA$Algul (I uo spodw Iso jL •£
(Longo -to # VojvjapunpawwqnSI
g'd `gpsdsmSjn opunutpg Aq Palms Pus pougls `So/I £/lo PajBp
`Mt-'IJA W a.todag 490y `•oui `Ajoisjogn•I Sugsay uopnmouod Aq patsdajd `loop
sseiS Smplis mnmarnje3° untjSetp uogelisui Pie sSalesBtP do-pa4rem quaSuois
tT6-ZOZ SH.L Pug (q) I'Z'£ I ItZ DIU jad `;so L A4uH Poojod (9
V6-£OZ SV.L `3t3d rad SuWe amssaid pm�, otio-(;J (S
V6-IOZ SVJL `aSd jod lsaZ aasdmI ollssryq oRwI (b
V6-ZOZ SVJL `jUd jad 'ls*Z 00ukqsm-d JMA% (£
b6-7AZ SVZ `a-S—u jad Buqmcq `IsaZ amssaid jV ognS uuo3tufl (Z
b6-ZOZ Sd.L `Otld jad `asas uogsmyur jar (I uo suodw 3sas •Z
(L07Z9"0 # Vojv-imnPaqw4nS)
.2[_d `-Pnd8MSJ I opunmpEIKq polms Pue PauS!s `SO/I Elio Pomp
`ysyV-Lyd 'oN:todag Isar `"oul 5koisjogvl Sugsa,L uot:sgsauad Aq paindajd `loop
ssgg Suipgs mnuitunis3o m iftip, uotpllo sut pus sSUUAWp do-pa*mm gpm Suole
M-£OZ SVJL `OEd jad guq)vo l amssatd pui
V6--I0Z SVJL `agd jod v* L aasdun olrsslq aSm7 (Z
t,6-ZOZ SVjL ` EU .tad WuWvcr j `Isas amssatd .tV oq%S uuojiufl (I uo spodaj Isar, •I
SISIL 'S
-a-d `ioutns matpuV seon7 Aq palms pug pains
`90/Zl/t, POMP S uoisinat gJIM SO/Si/t, PaxeP `,rajttiasgnusm Aq pomdatd `.,Oeduq
`1O°Q sselJ Buq)q " Id» Palms `LI3° LI ggwj% i smlS `T-9ott off 9"'clQ •Z
•suogos pug SOU.M jp aip s,.tamloWWW •I
S9NMVHG IV
(M LUKHaS TJNZQIAN :33xv.Ld3avSo �LLON
•auI sat gsnpul and
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
4. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Elroy Test, per FBC 24I 13.2.1(b) and TAS 202-94
along with marked -up drawings and installation diagram of an aluminum sliding glass
door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. F77, 4161,
dated 03/26/04, signed and sealed by Edmundo Largespada, P.E.
(Submitted under NOA # 04-0622. 07)
5. Test reports on 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of an aluminum sliding glass
door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-4163,
dated 03/25/04, signed and sealed by Edmundo Largespada, P.E.
(Submitted under NOA # 04-0622. 07)
C. CALCULATIONS
1. Anchor Calculations and structur-al analysis, complying with FBC-2004, prepared by
manufacturer, dated 5/12/06, signed and sealed by Lucas A. Turner, P.E.
Complies with ASTM E1300-98/02
2. Anchor Calculations, and structural analysis, dated 05123/05, and last revised on
07/22/05, prepared, signed and sealed by Lucas A. Turner, P.E.,
3. Anchor Calculations and structural analysis, complying with FBC-2004, prepared by
PGT Engineering, dated 06/17/04, signed and sealed by Lucas A Turner, P.E.
(Submitted under NOA # ".062207)
4. Revised Anchor Calculations, and structural analysis, prepared by PGT Engineering,
dated 10/08/04, signed and sealed by Lucas A. Turner, P.E.
(Submitted under NOA # 04-0622.07)
D. QUALITY ASSURANCE
1. Miami Dade Building Code Compliance Office (BCCO).
J Manuel Perez, P
G Product Control
NOA No
Fapirat on Date: November 11, 009
Approval Date: Augad 3, 2006
E-2
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 01-1204.01 issued to E.L DuPont DeNemours, for "Sentry
Glass ® Plus" dated 1/17/02, expiring on 1114/07
2. Notice of Acceptance No. 01-0205.02 issued to Solutia, Inc. for "SaflexlKeepsafe
Maximum" dated 05/17/01, expiring on 05/21/06.
3. Notice of Acceptance No. 00-1212.04, issued to E.I. DuPont DeNemours for their
"Dupont Butacite ® PVB", approved on 02/15/01 and expiring on 12111/05.
F. STATEMENTS
1. Statement letters of conformance and "No financial interest", both dated 05/23/05,
signed and sealed by Lucas A. Turner, P.E.
G. OTHER
1. Notice of Acceptance No. 05-0526.05, issued to PGT Industries, Inc. for their Seriers
"SGD-730 Aluminum Sliding Glass Door, approved on 08/25/05 and expiring on
11/11/09.
Ma�aoel
Product Goitre! Exdwdder
NOA No .03
Expiration Date: November 11, 2009
Approval Date: August 3, 2006
E-3
GENERAL NOTES: IMPACT SLIDING GLASS DOOR
GLAZING OPTIONS: (SEE DETAILS ON SHEET 2)
A. 7/16" LAMI CONSISTING OF (1) LITE OF 3116"ANNEALED GLASS AND (1) LITE OF 3/16' HEAT STRENGTHENED GLASS WITH AN .090 SENTRYGLAS PLUS (SGP)
INTERLAYER. TEST REPORTS FTL-4159 AND FTL-4161.
B. 7/16" LAMI CONSISTING OF (2) LITES OF 3/16' HEAT STRENGTHENED GLASS WITH AN .090 SENTRYGLAS PLUS IS (SGP) fNTEPLA-YEo TEST REPORT ;'T-415:
C. 7116" LAMI CONSISTING OF (1) LITE OF 3116' ANNEALED GLASS AND (1) LITE OF 3/16" HEAT STRENGTHENED GLASS WITH AN .090 PVB INTERLAYER OF
DUPONT BUTACITE OR SAFLEX/KEEPSAFE MAXIMUM PVB. TEST REPORT FTL-4171.
D. /16' rC�NS1S PING OF' 2)�LITES OF.I3/.18' HEAPSTRENGTFiENEDiGLASS WITH ANC=090 PVBItIVTFJ�LAYER OFiQUPO�iT_6UTACITE OR SAEI EX/KEEP_S . E
MAXIMUM•PVB�`TES�REP-ORT�IL"�1i:71. - - - - —=�
E.1 1/16" LAMI LG_ CONSISTING OF (1) LITE OF 3116' TEMPERED GLASS OUTSIDE, 7/16' AIR SPACE AND (1) 7/16' LAMI GLASS ASSEMBLY INSIDE.
THE 7/16" LAM[ COMPONENT IS ITEM C ABOVE. TEST REPORT FTL-4162.
F. 1 1/16' LAMI I.G. CONSISTING OF (1) LITE OF 3/16' TEMPERED GLASS OUTSIDE, 7/16' AIR SPACE AND (1) 7/16- LAMI GLASS ASSEMBLY INSIDE.
THE 7116" LAMI COMPONENT IS ITEM D ABOVE. TEST REPORT FTL-4162.
G. 9116' LAM[ CONSISTING OF (2) LITES OF 114" HEAT STRENGTHENED GLASS WITH AN .090 SENTRYGLAS PLUS (SGP) INTERLAYER. TEST REPORT FTL-4163.
2. CONFIGURATIONS: SEE DIMENSIONS SHEET 4 AND DIAGRAMS SHEET 5.
3. DESIGN PRESSURES: (SEE TABLES 1 THROUGH 6, SHEET 3)
A. NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300-98.
B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS TABLES ASTM E 1300-98.
C. DESIGN PRESSURES UNDER 40 PSF NOT APPLICABLE IN MIAMI-DADE COUNTY.
4. ANCHORAGE: THE 331/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. FOR ANCHORAGE DETAILS SEE SHEETS 14 THROUGH 17.
5. SHUTTERS ARE NOT REQUIRED.
6. INSTALLATION SCREWS, FRAME AND PANEL CORNERS SEALED WITH NARROW JOINT SEALANT.
7. REFERENCE TEST REPORTS: FTL-4159, FTL-4161, FTL-4162, FTL-4163, FTL-4171, FTL-4454 AND FTL-4524.
B. SERIES/MODEL DESIGNATION SGD730, 2-TRACK VERSION ALSO PREVIOUSLY REFERRED TO AS SGD70.
NOA DRAWING MAP
SHEET
GENERAL NOTES .............
1
GLAZING DETAILS ............
2
DESIGN PRESSURES.......
3
ELEVATIONS .....................
4
CONFIGURATIONS...........
5
VERT. SECTIONS .............
6-8
HORIZ. SECTIONS............
9-10
PARTS LIST .......................
11
EXTRUSIONS ....................
12-1;
ANCHORAGE .....................14-17
PRODUCT REVISED
m cutnnWraQ with the FlmNia
10 TECHNOLOGY DRIVE GENERAL NOTES AND MAP
NOKob11%" 3r".' r�"T'
P.O. cox 1529 ALUM. SLIDING GLASS DO.OR, IMPACT L .e,j A. T,r:.,, RE
NOK0.10.4 r=t 34274 Vi.ihlr 6erav '`""'""` s"11 —' °""°'"'° hE r58201
SGD730 NTS 1 •• 17 4406-1 a E Mechana�
EXTERIOR INTERIOR
(ALL SECTIONS)
7116" NO
3116" ANNEALED (OPT. A) OR HEAT 090 SENTRYGLAS PLUS INTERLAYER
STRENGTHENED GLASS (OPT. B)
` ,: Sfi' I-l�iaT :iRri�fir,i-IvFI :I ucc
1 1
46 39 or 55
49
591 NOM.
GLASS BITE
1 1/16' NOM.
3/16" ANNEALED (OPT. E) OR HEAT
_4 1
STRENGTHENED GLASS (OPT.F)
AIR SPACE
I I "1` I 1"'T •VGVFV5INTERu1fERISEENWE)
3116" TEMPERED GLASS --� �7 I _ 3/16' HEAT STRENGTHENED GLASS
47 ( 42 or 43
51 --!
591 NOM.
GLASS BITE
7=::i
t 1644 or 45 44 or 45 52 1 1/16" LAMI I.G. GLASS 52
GLAZING OPTIONS A & B GLAZING OPTIONS E & F
NOTE: PVB INTERLAYER IS DUPONT BUTACITE OR
SAFLEXIKEEPSAFE MAXIMUM.
7116" NOM.
9/16" NOM.
090" PVB INTERLAYER (SEE NOTE) .090 SENTRYGLAS PLUS
3/16' ANNEALED (OPT. C) OR HEAT 1/4" HEAT STRENGTHENED GLASS INTERLAYER
STRENGTHENED GLASS (OPT. D) 3/16" HEAT STRENGTHENED GLASS
1/4" HEAT STRENGTHENED GLASS
46 40 or 41
46 56
PRODUCTREVISED
49 o.6>cr Cc wim ma r a:
57 eD:a>Qa z�
Ascsn�wtJ o3
59 NOM. 59i NOM. r'c;�Ir;ticuL�ru Og
GLASS BITE GLASS BITE
Dmk_ �_tct
16 16 em n
44 or 45 44 or 45
/JMI�CL1SS� �i Bad 9/16" LAMI GLASS (SGP) 52 ,.
52
�-
GLAZING OPTIONS C & D GLAZING OPTION G
aswI D REMOVE L4Ml /.G. AIRSPACE DIAL. NOKOWS. FL 34275
"ff—r�
"`� ' �.. ALUM. SLIDING GLASS DOOR, IMPACT
1011,64 C a00 GLOSS TYPE G. 9116"LAME P.O. BOX 1529 Luc65 A ruueer. RE
Br Oan: NOXOM!S. FL 34274' V(tib& Better — s"i° �°"" "" PE #58201
Snaro4 ,.r. 4 rS65 SG0730 FUL 2 17 4406-i E Mechamuy
CONFIGURATION OVERALL WIDTH IN
INCHES
MAX. NOM. PANEL WIDTH >1
48"
60"
MAX. HEIGHT>
120"
96"
8
CONFIGURATION
PANELS
TRACKS
WIDTH
WIDTH
1
Xp OR pX
1
2
49 118
61 1/8
2
OX or XO BY-PASS
2
2
9613116
1M 1 1116
3
pXXp
2
2
10 11/8
125 1/8
4
XX BY-PASS
2
2
9613/16
IlZq 13/16
5
6
DXX orXXp
XOX BY-PASS
2
3
9
2
gg 1/e
I 1?n
144
180
7
000
3
2
1144
180
8
OXO BY-PASS
3
2
1149 3/8
185 3/8
9
pXXO or OXXp
3
2
148 13/16
184 13/16
10
OXX or XXO BY-PASS
3
2
149 318
135 3/8
11
OOX or XOO BY-PASS
3
3
144
180
12
OXX or XXO BY-PASS
3
3
144
180
13
XXX BY-PASS
3
3
144
1180
14
pXXX or XXXp
3
3
143 7/16
179 7/16
15
OXX or XXO BY-PASS
3
2 ,
149 3/8
185 318
16
0000
4
2
196 9116
244 9/16
17
OXXO BY-PASS
4
2
196 9/16
244 9/16
18
OXXXp or pXXXO
4
2
198
244
191
pXXXXorXXXXpBY-PASS
4
2 1196
244
20
XXXX BY-PASS
4
2
196 9/16
244 9/16
21
pXXxXp
4
2
195 1/2
243 1/2
22
OOOX or X000 BY-PASS
4
4
19 33116
239 3/16
23
OOXX or XXOO BY-PASS
4
4
191 3116
239 3116
24
OXXX or XXXO BY-PASS
4
4
191 3/16
239 3/16
25
XXXX BY-PASS
4
4
191 3116
239 3/16
26
pXXXX or XXXXp
4
4
190 518
238 518
27
XXXXX BY-PASS
5
3 1243
3/4
303 3/4
28
5x—xxxxxp
6
3 128913116
36113116
29
XXXXXX BY-PASS
6
3
29015/16
362 15/16
30
. pXXXXXXXXp
8
4 139
3/16
480 3116
31
XXXXXXXX
8
4 1385
114
481 114
FIXED PANEL CLIP (ITEM 18) LOCATIONS,
ITYP. ON ALL FIXED PANEL SIDE RAILS
•. I uL I �,, ; , POCKET
II
H{ lH �" Br JB
1
MAX, WIDTH _ I� MAX. WIDTH
(TABLE 8) 1 (TABLE 8)
XXp OR pXX
E[" 'E
I
POCKET I a
D1 f III -D jj��391/4"
TYtP.
I TABLE 8. (LOWER CASE p REPRESENTS POCKET INSTEAD OF JAMB) --L
MAX. WIDTH (TABLE 8)
DLO, SEE NOTE 6
F F n A[JA I
Al SEE SEE
NOTE 5 NOTE a
Gr lG � Hf �H
SEE NOTE 7
�— MAX. WIDTH (TABLE 8)
OXO
r
C
IN
I D
C
SOCKET
<3
a
B�
JB
Hr
lH
�+---
MAX. WIDTH (TABLE 8) — —
NOTES: Xp OR Xp pXXXO OR OXXXp
1. FOR VERTICAL SECTION DETAILS SEE SHEETS 6, 7 AND 8. FOR HORIZONTAL SECTION DETAILS SEE SHEETS 9 AND 10.
2. FOR APPROVED CONFIGURATIONS SEE SHEET 5.
3. FOR ANCHORAGE DETAILS SEE SHEETS 14 THROUGH 17.
4. MAXIMUM HEIGHT FOR DOORS WITH UP TO 4 FT. (48') WIDE PANELS IS 10 FT. (120'). MAXIMUM HEIGHT FOR DOORS WITH UP TO 5 FT. (60-) WIDE PANELS IS 8 FT. (96').
SEE -TABLE 8 FOR OVERALL WIDTHS OF APPROVED CONFIGURATIONS.
5. VERTICAL DAYLIGHT OPENING FOR 10 FT. HIGH (120') DOORS IS 112 3/4- MAX. AND FOR 8 FT. HIGH (96') DOORS IS 88 3/4' MAX. (DOOR HEIGHT - 7114'),
6. HORIZONTAL DAYLIGHT OPENING FOR 5 FT. (60-) WIDE PANELS IS 55 7116" MAX. AND FOR 4 FT. (46") WIDE PANELS IS 43 7116• MAX. (NOM- WIDTH - 4 9116').
7. FIXED PANEL ANGLE BRACKETS (ITEM 54) LOCATED AT THE HEAD AND SILL OF ALL FIXED PANEL INTERLOCKS, SEE SHEET 10 FOR DETAIL VIEW.
IW/06
1070 TECHNOLOGY DRIVE EXAMPLE ELEVATIONS&COA
NOKOMIS. FL 34275 ra
P.O. eox 1529 ALUM. SLIDING GLASS E
NOKOMIS. FL 34274 Wvibly Better 5—" S"` &'°"
SGO730 NT$ 4 - 17
IMPACT
4406-1
PRODUCT SZr : i2.L
8:7 iz-6-.3
i'd'ylm.:i.-'
.Y.; -. 03
NOV_ -c09
rat:.-• :a1 7" - . ,�- �
-�%
Lucas A. Turner. P.E.
PE #58201
Mechanical
ASTRAGAL
SIDE RAIL
PMDUCT REVISED
eS eumr'it'i09 al",lt Mt- F'A ios
UvfCtDn ode —
EXTERIOR INTERIOR _7L
(ALL SECTIONS)
TYP. VERTICAL SECTION SHOWING ONE TYP VERTICAL SECTION SHOWING
ACTIVE PANEL AND ONE FIXED PANEL TWO ACTIVE PANELS
t
rt2N5 E NoctwNGETHIS SHEET 1070 TECHNOVERTICAL SECTIONS, ORIGINAL 2 TRACK
R°11eo'•'OGY ORfVE
W05 D ADD STANDARD AND OPTIONAL S&L RISER HEIGHT DIM NOKOMIS. Ll..1115 —
Draw R' No CHANGE TwS SHEET P.O. BOX T529 ALUM. SLIDING GLASS DOOR, IMPACT L•.I A Tu,mr. P E.
cn .Y uW NOKOMIS. FL 34274 Visibly Better s.�siw.t s"` srr.� °G�'p NO R" PE #58201
IW4 JJ 411 SGO730 112 6 - i7 1 4406-1 F •-'
S, 58J59, LOCATED AT VERTICAL
60 O25 18 CENTER, 12" FROM TOP AND
BOTTOM OF FIXED PANELS
REINFORCEMENTS
42 27 GLASS TYPES A. B
REQ'D W/
OR G ONLY
(3) REQ'D
X
60 or 69
8, 66, 67, ^
O
ITEM 68 SHOWN
X
10
25
11
Si S,S21
or S24
— — —
— — — — — — — — — — —
ITEM S24 SHOWN
SECT. A -A
SECT. B-B
ONBL A '�SINGLEAINTERL( 90%
SECT. D-D
MOVABLE INTERLOCK AT P-HOOK
A
ITEM 68 SHOWN
A
ITEM S24 SHOWN
INFORCEMENTS REQ'D WI
ASS TYPES A, B OR G ONLY
"" - SECT. E-E
MOVABLE TO MOVABLE ASTRAGAL (INSIDE SHOWN) MOVABLE STILE AT .IAMB (INSIDE)
0 E ADD ITEMS 69AND 71. ALTERrurE 2 rRACK FRAME WISCREEN PAIL f07J4DR5IVE
HORIZONTAL SECTIONS
O"ADO7ANDaTRACKOPTIONSANOGLASSYPEGYY'REINF NOKOMIS.. R
T�
P.O. BOX 1529 ALUM. SLIDING GLASS DOOR, IMPACT
C NO CHANGE fHtS SHEET
cKaraer Due NOKOMIS, FL 34274 Visibly Better s`"" s..r
1/2 9 d 17 4406-1
59 ,&
4.
INTERIOR
(ALL SECTIONS)
EXTERIOR
PRODIrCr RE VISnED
as tort}Xy.'og with Slip Had&
BW tgCoda
Accen-,..oxi'I0
L'-
l'
bunni Prodaw C--1
1! o
Lucas A Turner. P.E.
PE 058201
Mechanical
HEAD AND SILL INTERLOCK & ASTRAGAL ANCHOR A. 7/16 LAMI (A, .090 SGP, H) B. 7/16 LAMI (H..090 SGP, H)
CLUSTER BY PANEL SIZE & GLASS TYPE C. OR E. 7116 LAMI (A.H) OR IN 1 1116 LAMI I.G G 9116" LAMI
D. OR F. 7116 LAMI (H.H) OR IN 1 1116 LAMI I.G. (H..090 SGP, H)
ANCHOR TYPE
DOOR HEIGHT
8 SUBSTRATE �•_,
72" (6p)
80"
W)
840
(7p)
90" IA
96' Iasi
102" IR4
108' 0)
114- (96)
12(r (10p)
pp
gg
v
z"
VT
mo
•Qp❑ pZ
o
QO p Z
QO Z
0
Qp Z
Q
Q
$ U
$ U Q
3 U
Q
ONOM.
O
wiO
Nn+_
INK
�fy n
I I
rMN� GL4AB
J
Q J
Q J
Q J
Q J_
¢
Q
J
Q
Q
Q
J
Q
J
Q
J
Q
��11
J
J
Q
JJWIDTHuW�
J
QJO
S rnS
m=
y
2vJ
2y
_
_�
=
_
to
=•
4J
=fD
(D
y24"(2)
-8
A
A
B
B
8
A
C
A
C
B
B
A
C
B
B
A
C
B
B
A
C
B
B
A
C
8
8
B
C
B
C,D
8
B
A
C
B
B
A
C
B
C
C8
8
C
C(Z)
B
8
A
C
8
B
A
C
$8B
g
C
C
B
g
C
C
B B C B B B C C B B C C B B D C
C,D
B
B
A
C
8
B
A
C
B
C
C
8
8
C
C
p
A,B,C,E
B
A
C
8
B
B
C
8
B
8
C
C
B
8'
O
C
B
B
D
C
B B C C B B O C C B D C C B D C
13)
n Fr.
R
R
r.
r.
R
R
n
r
R
R
n
47 (35
B
JBIAIC
B
D,F,G
JBIBIC
C
46• (4p)
A,C,E
JA
A
B 8
8 1
B
B
C
—co
D,F,G
8
B
C
54•(46)
A
B,G
6w (e)
A
ftAB
B,G
PPROVED ANCHORS: 1.
ELCO IW
IAMI-OADE COUNTY ANCH(
(2) ANCHORS REQUIRED E
(1) ANCHOR REQUIRED_Ai
;ILL AND JAMB LOCATION.
LOCATION. ANCHOR LOCATIONS TO BE STAGGERED.
INTERLOCK OR
h — ASTRAGAL CL
I._ WF D1F
CLUSTER A - (4) ANCHORS
INTERLOCK OR
�— ASTRAGAL CL
FF 81s" - BA" ;I
CLUSTER C - (8) ANCHORS
INTERLOCK O
I`--' ASTRAGAL CL
CLUSTER B - (6) ANCHORS
INTERLOCK OI
(--- ASTRAGAL CL
_.� 3" 3"
CLUSTER D - (10) ANCHORS
INTERLOCK OR
3• ASTRAGAL CL
- 4 3" 1 3' I �-
NOTE: 83/16'
DIMENSION IS
MAX. AND 3"
— — — + — — — O.C. IS MIN.
1--8k -1 8&" -•1 FOR ALL
CLUSTER E - (12) ANCHORS CLUSTERS -
JAMBS "' $iM9X1FRONl?8'OTCOM:AND 24' MAX. .C_ FORy1/4' TAPCONS O . CRETE-F(± E�(s16"'MAX:+.
u - O C..FOR�71`i2 SCREWS:
P-HOOKS....... 8" MAX. FROM BOTTOM AND 15" MAX. O.C. FOR 1/4' TAPCONS, CRE E=FL'EXIOR SCREWS.
3. MAX. 120' HIGH DOORS W/ PANELS UP TO 48" WIDE.
HEAD & SILL.. 81/4' MAX. FROM CORNERS AND APPLICABLE CLUSTERS) FROM TABLE 7 AT EACH ASTRAGAL AND INTERLOCK CENTERLINE.
16 3/8' MAX. O.C. (1/4• TAPCONS, CRETE-FLEX OR #12 SCREWS.
JAMBS ............ 8" MAX FROM BOTTOM AND 26" MAX. O.C. FOR 1/4' TAPCONS OR CRETE-FLEX. 22" MAX. O.C. FOR #12 SCREWS.
P-HOOKS.....-. 8' MAX. FROM BOTTOM AND 201/4' MAX. O.C. FOR 1/4" TAPCONS, CRETE-FLEX OR #12 SCREWS.
4. MAX. 96' HIGH DOORS W/ PANELS UP TO 60' WIDE.
HEAD & SILL.- 81/4' MAX. FROM CORNERS AND APPLICABLE CLUSTER(S) FROM TABLE 7 AT EACH ASTRAGAL AND INTERLOCK CENTERLINE.
2213116" MAX. O.C. FOR 1/4' TAPCONS OR CRETE-FLEX. 15 3/8" MAX. O.C. FOR #12 SCREWS.
JAMBS ............ 8" MAX FROM BOTTOM AND 22" MAX. O.C. FOR 1/4" TAPCONS OR CRETE-FLEX 15" MAX. O.C. FOR #12 SCREWS.
P-HOOKS....... 8" MAX. FROM BOTTOM AND 13 718" MAX. O.C. FOR 1/4" TAPCONS, CRETE-FLEX OR #12 SCREWS.
ANCHORAGE SPACING FOR DOORS INSTALLED OUTSIDE MIAMI-DADS COUNTY:
5. MAX. 96" HIGH DOORS W/ PANELS UP TO 48" WIDE -
HEAD & SILL........... 8 1/4" MAX. FROM CORNERS AND CLUSTER A, AT EACH HEAD AND SILL ASTRAGAL AND INTERLOCK CENTERLINE. 16 3/8" MAX. O.C.
JAMB..... 8" MAX FROM BOTTOM AND 2611/16" MAX. O.C. P-HOOK..... 8" MAX FROM BOTTOM AND 15" MAX. O.0
S. MAX. 120" HIGH DOORS W/ PANELS UP TO 48" WIDE.
HEAD & SILL........... 81/4" MAX. FROM CORNERS AND CLUSTER A, AT EACH HEAD AND SILL ASTRAGAL AND INTERLOCK CENTERLINE. 16 318" MAX. O.C.
JAMB...-. 8' MAX FROM BOTTOM AND 26' MAX. O.C. P-HOOK..... 8" MAX FROM BOTTOM AND 20 1/4" MAX. O.0
F. MAX 96" HIGH DOORS W/ PANELS UP TO 60" WIDE.
HEAD & SILL.--...-.... 8 1/4' MAX. FROM CORNERS AND CLUSTER A, AT EACH HEAD AND SILL ASTRAGAL AND INTERLOCK CENTERLINE. 22 13/16- MAX. O.C. .
JAMB..... B" MAX FROM BOTTOM AND 26 11116" MAX. O.C. P-HOOK..... W MAX FROM BOTTOM AND 13 7/8' MAX. O.0
r..saer wl. rae.em,.
F"t "i° IDTOTECNN060GYDR+VE
Fr4rS'!IS D CONDENSE 7A8tE 7 AlYD UF`GRAOE ANCHORgIiE PER F8C 2(Yu NOKOM1tIS. FL 17775
"°8' ALUM- SLIDING GLASS DOOR, IMPACT
FJC 1.0 RECALCNVCHOH GIPAG7IES, UPDATE SPAGNG NOTESAND TAB[E P.D BOX Mg ALUM.
Sty Dn�vw ..net oan cnc �"ae flare NOKOMIS. Ft 34274 V;x1h& Better
F.K 611&V4 JJ alsas sGDT3o 1/8 74 - 17 1 4406-1
EXTERIOR (ALL)
15
PRODUCTRMSED
e9 eomPlyLeg with the F7bri&
Baidin Code
Aa-�IaceNo - O
83'
PtmI1M ffc-l-,
DLi, i
I , , n Tweet. P E.
" P458201
E MEP.�'m.lica1
< ] EXTERIOR INTERIOR
- (CONCRETE) (ALL SECTIONS)
:5 •T .. 1 1/4"
:U MIN.
I WOOD BUCK -
SEE NOTE 2
I 114" 114" pp
I I I MAA. SHIM MAX. Y
1/4" TAPCON, SEE NOTE 1 ® #12 SCREW, SEE NOTE 5
BUCK
NOTE 2
SEE NOTE 1
NOTES: 1. MIN. DISTANCE FROM CONCRETE ANCHOR TO CONCRETE EDGE IS 2 112' FOR HEAD
2x WOOD
A SILL AND JAMB AND 1" FOR P-HOOK INSTALLATION. FOR CONCRETE APPLICATIONS I
SEE NOTE 2
MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED ELCO 1/4" TAPCOP
OR 114" ELCO SS4 CRETE-FLEX ANCHORS. FLAT HEADS TO BE #12 TRIMFIT TYPE.
2. WOOD BUCKS DEPICTED AS I ARE LESS THAN 1 1/2" THICK. lx WOOD BUCKS ARE
1 112"
OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE. WOOD BUCKS
MIN.
DEPICTED AS 2x ARE 1 1/2" THICK OR GREATER. INSTALLATION TO THE SUBSTRATE
OF WOOD BUCKS TO BE ENGINEERED BY OTHERS OR AS APPROVED BY THE
T , " ,ny
n11THOR!Tv H.AVINC- JLIR!SCICTiC": %AHJ).
SHIM
J. FOR ATTACHMENT TO ALUMINUM: THE ALUMINUM SHALL BE A MINIMUM STRENGTH
J
OF 6063 T5 AND A MINIMUM OF 1/8" THICK. THE ALUMINUM STRUCTURAL MEMBER
SHALL BE OF A SIZE TO PROVIDE FULL SUPPORT TO THE DOOR FRAME SIMILAR TO
THAT SHOWN IN THE DETAILS ON SHEETS 15 16 AND 17 FOR 2x WOOD BUCKS THE
FRAME HEAD INSTALLATIONS ANCHORS SHALL BE #12 SHEET METAL SCREWS WITH FULL THREAD ENGAGEMENT
T_1 j4" MAX! SCREEN
SHIu / FRAME
INTO THE ALUMINUM. IF THESE CRITERIA ARE MET, THE PRESSURES SHOWN ON
2x WOOD SHEET 3 AND ANCHORAGE SPACING FOR 412 SCREWS SHOWN ON SHEET 14 MAY
SEE NOTE 2 BE USED.
4. SCREEN FRAME AND DOOR FRAME MAY BE ATTACHED TO DIFFERENT SUBSTRATE
TYPES AS REQUIRED TO ACCOMMODATE THE EXTRA DEPTH OF MULTI -TRACK
_ 1 1/2" CONFIGURATIONS, AS APPROVED BY AHJ. DESIGN OF COMPOSITE WOOD/MASONRY
MIN
MID
OPENINGS DONE BY OTHERS OR AS ACCEPTED BY AHJ. FASTENER SIZE,
EMBEDMENT, AND SPACING MUST BE AS INDICATED FOR THE SUBSTRATE INTO
11 "MAX- WHICH THE FASTNER IS EMBEDED.
SHIM 5. FOR WOOD APPLICATIONS ELCO 1/4' TAPCONS OR 1/4" SS4 CRETE-FLEX ANCHORS
A WITH #12 TRIMFIT HEADS MAY BE USED INSTEAD OF #12 SCREWS. SEE TABLE 7.
#12 SCREW, SEE NOTE 5
ALTERNATE 2 TRAC'KOFRAME--
® W/ SCREEN RAIL
(CONCRETE)
11/4
lx WOOD BUCK 1 MIN.
SEE NOTE 2
SCREEN FRAME ! T—1/4" MAX.
L SHIM SCREEN FRAME
1/4" TAPCON, SEE NOTE 1
3—TRACK FRAME HEAD INSTALLATIONS
(CONCRETE) f
1 1/4"
I WOOD BUCK - MIN.
SEE NOTE 2
SCREEN FRAME 114" MAX. SCREEN I~!
1 SHIM FRAME ti ti fi
114" TAPCON, SEE NOTE 1
4—TRACK FRAME HEAD INSTALLATIONS
2x WOOD
SEE NOTE 2
1 1/2"
MIN.
L 1/4" MAX. SHIM
#12 SCREW, SEE NOTE 5 A
2x WOOD
SEE NOTE 2
- - 1 112"
-_ MIN.
1/4" MAX. SHIM
#12 SCREW, SEE NOTE 5 A
1070 TECHNOLOGY DRIVE =1 ANCHORAGE DETAILS, HEAD
3 A 4-TRACK AND ALTERNATE? -TRACK OPTIONS NOKOMIS. FL 34275 »t
E 1 P.U. 80X 1529Inic.-ri ALUM. SLIDING GLASS DOOR
NOKOMIS FL 34274 Vi..dh& Better "" scw s °ir"
sc0730 1/4 15 v 17
4406-1
PRO01A If REi'SS€T
3s c 9c;A':iva wtfh9SC Rarxit
c'g itiM„ C:Ks
nnc
fi.{;at2: a is PmeS9'_t (�nsi. of
L.;aS P.. 'fuMPI- P.E.
PE 058201
Mechanical
1 1/2" MIN.
#12 SCREW
SEE NOTE 5. 2x WOOD
SHEET 15 r — SEE NOTE 2
SHT. 15
�I
1/4" MAX. SHIM — �{
1x WOOD BUCK 1 1/4' MIN.
SEE NOTE 2
SHT. 15
1 /4" TAPCON
SEE NOTE 1
SHT. 15 (CONCRETE)
tiv,
114' SHIM MAX —�I i"-
ORIGINAL 2-TRACK FRAME
JAMB INSTALLATIONS
1xWOOD BUCK
SEE NOTE 2
SHT. 15
'II
1%4' TAPCON
SEE NOTE 1
SHT. 15
1
SCREEN _ _��
FRAME
1/4" SHIM MAX-
1 1/4" MIN.
'(CONCRETE)
1 1/2' MIN.
#12 SCREW
SEE NOTE 5.
® SHEET 15 2x WOOD
i SEE NOTE 2
SHT. 15
SCREEN
FRAME
1/4' MAX. SHIM --i F-
_. til 1 1/4" MIN.
EE NOTE 2
,
o
A4-
SHT.15
ti
2 TRACK FRAME
'
W/ SCREEN RAIL
1/4' TAPCON
SEE NOTE 1 --�
SHT. 15
1/4" SHIM MAX.
—+{
1 1/2" MIN.
#12 SCREW
SEE NOTE 5,
® SHEET 15
1 I
2x WOOD
SEE NOTE 2
SHT. 15
SCREEN
FRAME
1/4' SHIM MAX.
3-TRACK FRAME JAMB INSTALLATIONS
5
'p TECHNOLOGY OR
NOKOMIS. FL 34275
P.U. BOX 1529
NOKOMIS. FL 34274
I+ 1 112" MIN.
#12 SCREW
SEE NOTE 5. 2x WOOD
® SHEET 15 SEE NOTE 2
SHT. 15
i'
i
SCREEN
FRAME " ,
1/4" SHIM MAX. ---I {-----
1x WOOD BUCK
SEE NOTE 2
SHT. 15
1/4' TAPCON
SEE NOTE 1
SHT. 15
■1
i
SCREEN
FRAME
1/4' SHIM MAX. —� { �—•
1 1/4" MIN.
,r. (CONCRETE)
,4
4-TRACK FRAME
JAMB INSTALLATIONS
ANCHORAGE DETAILS, JAMB
M
ALUM. SLIDING GLASS DOOR, IMPACT
sn.an�n swr si..r aw.yw
SGO730 114 1 16 . 17 4406-1
L^a
u
INTERIOR
(ALL SECTIONS)
EXTERIOR
ID
PRODUCT REVISED
a cum*bq witts ft Awids
AAoceptzam No O�
- man,
*9ietal a Ptidect Coates!
Lug"s A '.umr, P.E
PE #58201
McChanical
EXTENDED SILL (3112" ), MAX. 96- (S") HIGH DOOR. TABLE
ALL CONFIGURATIONS WITH A MAX. NOW PANEL WIDTH OF 60" (5°)
GLASS TYPE A. 7/16" LAMI (3/16" ANN... 090 SGP, 3/16" HS) FTL-415
om.
Panel
Door Height
Width
72" (6°1
80" (6e)
84" (70)
90" (76)
30" (2`�
36" (39)
+70.0
+70.0
-70.0
1 -70.0
1 +70.0
+70.0
-70.0
-70.0
1 +70.0
+70.0
-70.0
-70.0
1 +70.0
+66.8
1 -70.0
1 +70 0
1 -70 0
66.8
+64.8
64.8
42" (3B)
+62.6
-62.6
+56.7
-56.7
+53.9
-53.9
1 +50.7
-50.7
+48.2
48.2
44" (40)
+53.2
-53.2
+47.2
47.2
+44.4
-44.4
+42.3
-42.3
+40.6
-40.6
54"(4)
+46.2
-46.2
+41.3
41.31
+39.4
-39A
+37.1
-37.1
+34.6
-34.6
60" (5)
+41.7
i -41.7
+37.6
-37.6
+35.8
-35.8
1 +33.1
-33.1
+30.9
-30.9
EXTENDED SILL (3112% MAX. 96" (8) HIGH DOOR. TABLE 2A.
L SIZES AND CONFIGURATIONS WITH A MAX. NOM. PANEL WIDTH OF 60" (5°)
GLASS TYPE G. 9/16" LAMI (1/4" HS,.090 SGP, 1/4" HS) FTL-4163 +70.0 I -70.0
EXTENDED SILL (3 1/2"), MAX. 96" (8) HIGH DOOR.
TABLE S.
ALL CONFIGURATIONS WITH A MAX. NOM. PANEL WIDTH OF 48" (4)
GLASS TYPEC. 7/16" LAMI (3/16" ANN...090 PVB, 3/16" HS)
FTL-4171
GLASS TYPE E. 1 1116" LAMI LG W/ 7/16" LAMI TYPE C.
FTL-4162
(3/16" TEMP., 7116" AIR SPACE, 3/16" ANN.,.090 PVB, 3/16" HS)
om.
Daccr Height
ranei
Width
72" (6)
80' (6)
84" (70)
1 90" (7B)
96" (8°)
30" (2)
+80.0
-80.0
+80.0
-80.0
+80.0
-80.0
+80.0
-80.0
+80.0
-80.0
36" (3°)
+76.6
-76.6
+72.7
72.7
+70.6.
-70.6
+66.8
-66.8
+64.8
-64.8
42" (3e)
+62.6
-62.6
+56.7
-56.7
+53.9
-53.9
+50.7
-50.7
+48.2
-48.2
48" (4°)
+53.2
-53.2
+47.2
-47.2
+44.4
-44.4
+42.3
-42.3
+40.6
-40.6
EXTENDED SILL (3 1/2"), MAX. 96" (8°) HIGH DOOR. TABLE 6.
ALL SIZES AND CONFIGURATIONS WITH A MAX. NOM. PANEL WIDTH OF 48" (40)
GLASS TYPED. 7116" LAMI (3/IW HS,.090 PVB, 3/16" HS) FTL-4111 +80 0 -80.0
GLASS T'YPEF. 1 1/16" LAMI I.G W/ 7/16" LAMI TYPE D. FTL-4162 +80.0 1 -80.0
(3/16" TEMP., 7/16" AIR SPACE, 3/16" HS490 PVB, 3/16" HS)
EXTENDED SILL (31/2% MAX. 120" (100) HIGH DOOR. 4LELL SIZES AND CONFIGURATIONS WITH A MAX. NOM. PANEL WIDTHOF 48GLASS TYPE B. 7/16" LAMI (3/16" HS,.090 SGP, 3/16" HS) FTL-4161 +60.
EXTENDED SILL (3 1/2"), MAX. 120" (10) HIGH DOOR.
ALL CONFIGURATIONS WITH A MAX. NOM. PANEL WIDTH OF 48- (4°)
GLASS TYPE A. 7/16" LAW (3116- ANN.,.090 SGP, 3/16" HS)
TABLE 3.
FTL-4161
Nam.
Panel
Door Height
Width
72" (fiq
80" (6)
84" (7)
1 SW (7e)
96" (8)
102" (8)
108" (9q
114' (9)
120" (10)
30' (2)
+60.0 1
-60.0
+60.0
-60.0
+60.0
-60.0
+60.0
-60.0
+60.0
-60.0
+60.0
1 -60.0
+60.0
-60.0
+60.0
-60.0
+60.0
-60.0
36" (3)
+60.0
-60.0
+60.0
-60.0
+60.0
-60.0
+60.0
-60.0
+60.0
60.0
4.60.j
60.0
+60.0
-60.0
+58.9
-58.9
+58.2
-58.2
42" (36)
+60.0
-60.0
+56.7
-56.7
+53.9
-53.9
+50.7
-50.7
+48.2
-48.2
+46.46.3
+44.6
-44.6
+43.4
-43.4
+42.1
-42.1
48" (q)
+53.2
-53.2
+47.2
-47.2
+44.4
-44.4
+42.3
-42.3
+40.6
-40.6
+38.38.3
+36.0
-36.0
NOTES:
REVISED
x pidi the f inri4L,
1. POSITIVE DESIGN PRESSURE IS LIMITED TO +40.0 PSF FOR ALL SIZES AND CONFIGURATIONS NOT EQUIPPED WITH 31/2' EXTENDED SILL RISER. NEGATIVE PRESSURES
ARE NOT CHANGED. SEE VERTICAL SECTIONS, SHEETS 6 THROUGH 8 FOR EXACT SILL HEIGHTS. J
2. REINFORCEMENTS NOT REQUIRED IN DOOR PANELS WITH GLASS TYPES C, D, E AND F (TABLES 5 AND 6). REINFORCEMENTS ARE REQUIRED IN DOOR PANELS WITH } i ; ; ✓ 6:
GLASS TYPES A, B AND G (TABLES 1, 2, 2A, 3 AND 4).
TABLE
1077ECHNOLOGE
4Z75 NOKOAi1S. F( 3J275
P.O. BOX 1529
NOXOMIS. FL 342?4 1 I/jSj,4 v Ber(e-r
DESIGN PRESSURES
KUM. SLIDING GLASS DOOR, IMPACT
spar sneer Lucas A V.E.
PE p58201
58201
sco?3o FUL 3 - 17 � 4406-1 �E I Mein+cai
SCREEN & #12 SCREW,
FRAME SEE NOTE 5, SHT 15
1/4' MAX.
SEE I 112"MIN.
E
NOTE 1 2-x WOOD
SCREEN SHT. 15
FRAME
1/4"TAPCON
1/4' MAX.
SEE NOTE 1 SEE NOTE I SHT. 15
114!MIN.
(CONCRETE)
4-TRACK-FRAME SILL INSTALLATIONS
A
ANCHORS ARE STAGGERED 1' MIN. AT P-HOOK
ANCHOR EMBEDMENT AT P-HOOK' 1/4"TAPCON -I 1/4" MIN.
114" CRETE-FLEX -1 314" MIN.
Ix WOOD BUCK
(CONCRETE) SEE NOTE 2 (CONCRETE)
1 1/4"
MIN. 3/8'M
1 114" SHT. 15
3/8"MIN.-I IN.MIN.,
1/4' TAPCON T
(SEE NOTE 1)
SHT.15
101
INTERIOR
(ALL P-HOOK SECTIONS)
EXTERIOR
lu
& #12 SCREW.
SEE NOTE 5, SHT 15
SCREEN FRAME
1/4" MAX. 1 1/2" MIN.
SEE NOTE 1
9v WOOD
SEE NOTE 2
& - #12 SCREW,
SEE NOTE 5, SHT4
SCREEN FRAME
1/4' MAX. t2" MIN,
SEE NOTE 1
,x WOOD
SCREEN SHT. 15
FRAME -%SEE NOTE
114"TAPCON 1/4'TAPCON S 15
KT�Q,
1/4" MAX. SEE NOTE 1 1/4*1 SEE NOTE 1
SEE NOTE I SHT. 15 SE 4 TE1 SHY. 15
1114"MIN.
•
1114' MIN.
(CONCRETE) (CONCRETE)
SM
3JRACK FRAME SILL INSTALLATIONS E; R � E
,&ALTERNATE 2 TRACK FRAME W1 SCREEN RAILS-MONSWAOMMI NS'_/
EXTERIOR INTERIOR
(ALL SILL SECTIONS)
3/8' MIN.—�
T 1'1/4"TAPCON #12 SCREW
T (SEE NOTE 1) SEE NOTE 5
SHT . A SHT. 1�
. I 5
TYPICAL POCKET P-HOOK INSTALLATIONS
#12 SCREW, SEE NOTE 5, SHT. 15
I I
- I 1/2"MIN.
114- MAX. 1 112" MIN.
SEE
NOTE 1
2
2x WOOD x WOOD
SEE NOTE 2 SEE NOTE 2
—4 SHT. 15 SHT. 15
1/4!TAPCON
SEE NOTE I
SHT. 15
1/4"M SEE NOTE
1/4' MIN.
(CONCRETE) E)
ORIGINAL 2-TRACK FRAME
SILL INSTALLATIONS
NOTE:
1. IF SILL IS TIGHT TO SUBSTRATE, GROUT OR OTHER MATERIAL IS NOT REQUIRED. IF USED, GROUT OR OTHER MAIL (DONE BY OTHERS) MUST
FULLY SUPPORT THE ENTIRE LENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE. AND TRANSFER SHEAR LOAD TO SUBSTRATE.
ALTERMTE2 TRACK FRAME WISCREEN RAIL AND P-HOOK CHANGE. 1070 TECHNOLOGY DRIVE ANCHORAGE DETAILS, SILL & POCKET P-HOOI
13 4-TRACK AL TURNAT62-TRACK OPTIONS AND GROUT NOTE NOKOMIS FL 34275 rm
4ANGE TSHEET P.U.P.. 60,1( 1529 ALUM: SLIDING GLASS DOOR, IMPACT
- - J - 1w__ - lR_
NOKOMIS. FL 34274 vixib�y Bvru� I SGD730 114 1' 17 - 17 4406-1 E
PRODL;C"T REVISED
L"151 %. Tilmer. RE
Pt 1158201
Me haWcal
8.038 = 6.130 -� I 4.222 -�-j
ill--i 494
r r �r,� ��
078 I
ji f 11 i 2.625 076
1 i 625
078
�. I
2 625 }
1 E 2.713
.078
rR . Q TRAr.W Cu 1 2 T R ACI" SILL 6 i - o I ANFiAKU 6iLL ikiSE <
MATL: 6063-T6 MAT'L: 6063-T6 MATL: 6063-T6 MATL: 6063-T6
DWG# 4407 DWG# 4408 DWG# 4409 DWG# 4410
_494
3.500
.078 -- -i
I.
rl
62 - 3.50" SILL RISER
MAT'L: 6063 T6
DWG# 4411
8.038 -y� 6,130 �-1 r- 4.222 8.038
1 �-- 6.130 1
dkJl_I�JL�cti�jn a r��--�-,uv� fls �l�I
1.619 U u� �1.619 I1 }! ��U�U 1.235 1� --}n 1.235
l �I ��)---at_- 111 11r
.018 --�°r 1 .078 --��- I o78 --��- 1.619 078 ,078 ---�� -
63 - 4 TRACK HEAD
MAT'L: 6063-T6
DWG# 4412
f+- 4.222 ---1 1
1.235
68 - 2 TRACK JAMB
MATL: 6063-T6
DWG# 4417
0 2.646 i•-•-
1.619 rr
F-- 4ll a - .o78
S21 - SCREEN
2 TRACK FRAME JAMB
MAT'L: 6063-T6
DWG# 4423
64 - 3 TRACK HEAD 65 - 2 TRACK HEAD
MAIL: 6063-T6 MATL: 6063-T6
DWG# 4413 DWG# 4414
3.810 -�-•I
A LI;
-�11 .078
S16 - SCREEN
3 TRACK FRAME SILL
MATL: 606346
DWG# 4418
-�-{ 1.283
I .810
.078 -y III
S22 - SCREEN
1 TRACK FRAME SILL
MATL: 6063-T6
DWG# 4424
Fes- 5,505 -�I�
1.619
.078F-
70 - FRAME, 2 TRACK HEAD WI SCRE N RAIL
® MAT'L 6063-T6
L1- 3.810
1.619rrr
078 --� 1--
S11- SCREEN
3 TRACK FRAME HEAD
MATL: 6063-T6
DWG# 4419
1.283
1,619 r--4I--- .078
F
S23 - SCREEN
1 TRACK FRAME HEAD
MAT'L: 6063-T6
DWG# 4425
L3.810
1.619 i
F.078---
S18 - SCREEN
3 TRACK FRAME JAMB
MATL: 6063-T6
DWG# 4420
01,283 r --
1.619 u �_ ,0
S24 - SCREEN
1 TRACK FRAME JAMB
MAT'L: 6063-T6
DWG# 4426
1+- 5.505 1
1.235
,.� 0--7.--8---t�tI--}
a17FRA E, 2 TiRAGK WtI51EL�IRAIL
® MATL: 6063 T6
66 - 4 TRACK JAMB
MATL: 6063-T6
DWG# 4415
.1L25.
46
F.078 -�►- -
S19 - SCREEN
2 TRACK FRAME SILL
MATL: 6063-T6
DWG# 4421
78
67 - 3 TRACK JAMB
MAT'L: 6063-T6
DWG# 4416
2�.5(4�6'''j�
1.619
F-III►--= .078
S20- SCREEN
DWG# 4422
5.505 - --- -1
Fti
� 2.625
JL 1��1
.078 ---0
® MATL:6063-T6
DWG# 4442
a�
a- x ii: the
D:
1070 MCnNOLOGr oR1Ve �.....
.. • .--- - • ••�
OPTIONS NOKOILIIS. FL 34275 rae
P.O. Box 1529 ALUM. SLIDING GLASS DOOR, IMPACT L,,,;;1s A. Tu,.w. P.E.
NOK0611S, FL 34274 V%ihly Better s'"P.''1od11� x» skier a-*wy R., PE 958201
SGD73D NTS 13 a 17 4406-1 E rtecnaracal
Le
MAIN FRAME EXTRUSION PROFILES
2-TRACK 3-TRACK 4-TRACK
2.,13
SILL
�73 2.713 1.3761 � � 1.3.13€
-4.3os
1
HEAD ,s1A J1s U —i a
1s1e � e �
2M �. 1
4,
JAMB
�1 8.
' r
1,?33
4
1.�55
Z TRACK WITH INTEGRAL SCREEN RAIL
7
JAMB
i n n
�L
.
6.506