Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDate. I Fee Due: J o a�rO Receipt# Permit # 0'&-- (8 'PD�St. Lucie. County Building & Zoning.Department -c 23700 Virginia -Avenue • = Fort. (� Pierce, FL_ 34982 �C,�N� OR1 462 1553 �,t `UC%�Y APPLICATION FOR REPLACEMENT OF CO1117ty WINDOWS, SKYLIGHTS, DOORS & OVERHEAD .GARAGE DOORS: LOCATION/SITE ADDRESS: ?j 1 6b j\h . A 1 A- : - P- << SECT I I TWP RNGoE MAP �/ NG — PARCEL ID NUMBER: 14125 .. fo06 6)D(p4 — nvr) i. DESCRIPTION OF PROJECT OR WORK ACTIVITY: Ep_80 � � �� S.G - boo a-S TYPE OF STRUCTURE: ❑ .SFR 4''..OTHER , . (JQ h) j aW L A11 U (n OWNER INFORMATION 6. CONTRACTOR INFORMATION Name: po%g 6 • S564LIS aW FL Reg/Cert #: Addressl. Un t� p , A J A County Cert#: City: State: L • . Business Name: 1:1-D91BA Awluii;t6iA Zip: Phone: 7i2`�{fo� ��3%. Phone))2 Moo Fax - -77a- 'roduct Table 1606.2B * 15' maximum height Minimum Design Pressure Design - Pressures 0:-70 'Manufacture . P -. �T ��.,S . Model Number 73 O NOTICE OF ACCEPTANCE # FLORIDA # No— d sa3• 0 3 130 mph 140 mph iv auuvna.ac Exposure..0 ** I 49.2. 57:1� = I I awing & Garage. Doors Ex osure--B 38 44 Ex osure C ** 45.9 53.2. VALUE OF CONSTRUCTION:. $,. T, (�- +Ob NNER'S AFFIDAVIT: I certify that all of the information contained. in this application is ect and th all work will:be done in compliance with all applicable laws regulating const trn and o ng. i C�WAXt Scott THOWSonl PRINT QUALIFIERS/OWNERS NAME SIGN OF A 1FIER/ ER STATE OF FLORIDA, COUNTY OF S%L(0d/E OWLE BEFORE ME THIS DAY OF I I tT, 20 77 BY CIW PA) JS2M "'(R W WHO ERSONALLY KNOWN ME OR WHO HAS PRODUCED - - AS IDENTIFICATION. ��""""°�� MAUREEN J. AL�jLQ�� SIGNATU O NOTARY TYPE OR PRINT NAME OF NOTAR MY COMMISSION #D19ilt8dl9 n� FJPIRB: September 03, 2010 TITLE: NOTARY PU COMMISSION NUMBER i�a�a•xaraav F9•NaaryDsaowtAtsoc Co. Window. Skylight, Doors. Garage Door permit application 7/18/05 dmR w NOTICE TO OWNER: YOUR FAILURE TO -RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING -TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. ❑ Attach 2 eopies of the N0A�oi.'F1oiida approval With details'to the product being used INSTRUCTIONS Please complete all information in the.space provided. All information must be Printed (useblack or blue ink only) or Typed. This application for replacement of Windows, Skylights, Doors &Overhead doorstto be used for only those -activities that. are not otherwise included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteratii q.. 3uildingiactivities,involving__structural-alteration,.in addition to the replacement of Windows; _Skylights, Doors & Overhead doors; must be permitted through the regular building permit review process. The information to lie provided with this application ,f includes: 1. LOCATION/SITE ADDRESS: ................................... `,Indicate the, street address, or general location, of the property on which ilie-luilding activity is taking'place. 2. PARCEL ID NUMBER: ...... ...... .............. ....................... Indicate the Property Tax Identification Number forthe property -on which the building activity is.tal ing place. 3. DESCRIPTION OF PROJECTOR WORK, ACTIVITY........ Briefly describe the building activity under permit application- 4: ,,: OWIJERS INFORMATION;.......... :.....:.::............................. Indicate the name and address of the owner of the property on which ` the product is to be insfalled: ' 5. CONTRACTORS INFORMAT.ION:...................:... Indicate the State of 1760&(if applicable). and St. Lucie ' contractors registration numbers, and the name of the business doing the work.' 6. VALUE OF CONSTRUCTION :..:.....:::............. ' ; : Indicate.,the-total'walue' 4the-work to take place. Total cost of construction includes all material and labor costs associated With the . building/construction activity. The value of construction is. used to determine the amount of permitting fees to be assessed. St: Lucie• .. County reserves the right -to question and/or modify_ the. indicated value of construction if it is demonstrated that.the`subniitted figures. -. are not consistent with similar types of construction: All applications for Permits are to. besubmitted to the St. Lucie County Building and Zoning Department; St. Lucie County Administration . Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for'Permits must be complete and. filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M: For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553; during regular office hours (8:00 AM - 5:00 PM), Monday through. Friday. Following the issuance of this Windows, Skylights, Doors & Overhead,do_ors replacement Permit, the scheduling of all required inspections may be made by calling (772) 462-1261. - SLCCDV FORM NO: 006-05 Window, Skylight, Doors, Garage Door permit application 7/18/05 dmg f Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 hftp://stlucieco.gov/ce BUILDING PERMIT Page 1 Issued: 05/24/2007 Conf #; 545 Permit #: SLC- 0705-0387 Job Location: 3100 Al 405 City: FORT PIERCE Permit Type: Building (Miscellaneous) Job Description: REPLACE SLIDING GLASS DOORS TO IMPACT SLIDING GLASS DOORS FOR A CONDOMINIUM Subdiv: Sands on the Ocean Section 1 - Condo Lot: Block: Parcel: 1425-606-0009-000/1 Contractor THOMPSON EDWARD S T/A FL AWNING GLASS & SCREENIN, (772) 461-8500 480 SOUTH MARTKET AVE FT PIERCE, FL 34982 Property Owner POLLY E JOHNSON (TR) (772) 467-9437 HILLSIDE FARM 257 DAVIS RD CAVENDISH, VT 05153 Setbacks Left: Right: Front: Rear: Zoning: HIRD Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: Flood Zone: Elev: Job Value: $15,000.00 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stfucleco.gov/ce Date: 24 May 2007 Job Address: 3100 AlA 405 Received By: spellsv Paid With: CK Paid By: FLORIDA AWNING & GLASS Building � Receipt Sign: Receipt#: 0000054391 ermit Number: SLC- 0705-0387 Amount: $130.00 'redit Card Number: Check Number: 48962 EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY . FILE # 3059457 OR i K 2822 PAGE 2016, Recorded 05/24/2C�--Yat 11:17 AM Permit No. State OfTF:Iy P-tDA NO11C'E OF COMMENCEMENT 'rac.iDi 111A5— (006-0009-000—) Count l Of THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Comtnenc�ment. and street address, if General description of improvements .=rAAAQ.3 -sL ti11N&, G1At�boy2S Owner jM4 E..3r)f4NS0 1V Address1{lµtt e� FA�run �s� �.ilC RA� �►�__�T' o srs 3 Owner's interest in site of improvement _ Fee Simple Titleholder (if other than owner) Address Contractor R oa,m kF IJ SU d T1 UYY s 0) Phone # 17a - 01- 450 Address49D Si,- spate ET a R" At • 16 _ft- il=6. 24A f2 Fax # 77a" bbh jV Q- Surety _ Address Amount Phone # Fax # Lender _ - — _ Phone _ Address Fax # Penns within the State of Florida designated by Owner upon whom notices or ether documents may be served ti provided by Section 713.13 (1) (a) 7., Florida Statutes: Name_ _ ___ _�_ Phone # Address Fax# In addition to himself, owner designates of - (Phone # Fax # ) to:'eceive a copy of the Lienoes Plotlee as provided in Sectitm 71 • .I3(1)(b}, Florida Statutes. Expiration date of notice of commencement is one year from the date of recording unl ss a different date is spec: fled. (Date) OK S SIGN RE STATE OF FLORIDA. COUNTY OF _ST .to .0 E Aclmowledged before me thiseaZ-, day of _ _M[[}n, who ' ersonally known me of who has produced ^ uts r entification. 1 . (seat) SIGN TURF O *IOTAR -YP 1 OR PRINT NAME OF NOTARY THISTO CERT-1- = T{,f , '"1S I A :.v T `tli)r f OFTHIb TRUE AND{;*,,i ®RIG Vy C EI3.. Uw .WLEiA_v0 T iiO TARP PUBLIC. 'SITLE _ _COMMISSION MWER MAL►REEN I. ALLEN g d MY COMMISS(ONNDDr86819 ?wM' ����tmba 07, Y010 lacalt+ocVty ftNanyDirpet�roc Cn Property Appraiser - St.Lucie County, FL Page 1 of 1 --e; PROPERTY RECORD CARD Polly E Johnson (TR) Record: 1 of 1 <<Prev Next » Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification C�Gy Site Address: 3100 N A1A ParcellD: 1425-606-0009-000-1 \���UCIF e Secrrown/Range: 25 :34S :40E Account #: 8877 Map ID: 14/25S Land Use: Condo d - Zoning: City/Cnty: ST. LUCIE COUNTY Ownership and Mailing Legal Description Owner: Polly E Johnson (TR) SANDS ON THE OCEAN -SECTION 1- UNIT 405 (OR 1371-325, 329) Address: Hillside Farm 257 Davis Rd Cavendish VT 05153 Sales Information Assessment Final Total Land and Building Date Price Code Deed Book/Page 2006 Val: 310000 Land Value: 0 Acres: 0 3/2/2001 65000 04 WD 1371 / 0329 Assessed: 310000 Building Value: 810000 2/26/2001 65000 04 WD 1371 / 0325 Ag.Credit: 0 Finished Area: 1207 SgFt 2/17/1994 100 01 WD 0886 / 1901 Exempt: 0 11/1/1986 129900 00 CV 0523 / 0614 Taxable: 310000 TotalTax: 6206.26 BUILDING INFORMATION A Exterior Features lm-agQ 2 vailable 3900 View: Ocean RoofCover: - RoofStruct: - View ExtType: X131 - SndOTOcnSc1 YearBlt: 1983 Frame: - Grade: NT - NT EffYrBit: 1983 PrimeWall: - StoryHght: 0010 - 1 Story No.Units: 1 SecWall: - Interior Features BedRooms: 2 Electric: - PrmintWall: - FullBath: 2 HeatType: - AvgHUFI: STD 1/26ath: 0 HeatFuel: - Prm.Flors: - %A/C: 0 %Heated: 0 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBlt. No. Land Use Type Measure Depth PUNT - PUD UNIT S 1 310000 AV AV 0 1 0400-Condo N -No Land Val 0 0 CLiv - CondoLivArea S 1 1207 AV AV 0 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.paslc.org/prc.asp?prclid=142560600090001 5/24/2007 4 TV . V f Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce INSPECTION CARD Permit #: SLC= 070_0387- — Conf #; 545 Type: Building (Miscellaneous) Issued 05/24/2007 Double Fee: No Job Location 3100 Al 405 City, FORT PIERCE Jurisdiction: St. Lucie County Lot; Block: Parcel: 1425-606-0009-000/1 Subdiv: Sands on the Ocean Section 1 - Condo Owner: POLLY E JOHNSON (TR) Flood: Elev: Flood Map: Project: Job Description: REPLACE SLIDING GLASS DOORS TO IMPACT SLIDING GLASS DOORS FOR A CONDOMINIUM Contractor THOMPSON EDWARD S T/A FL AWNING GLASS & SCREENIN, (772) 461-8500 480 SOUTH MARTKET AVE FT PIERCE, FL 34982 Property Owner POLLY E JOHNSON (TR) (772) 467-9437 HILLSIDE FARM 257 DAVIS RD CAVENDISH, VT 05153 Setbacks Left; Right Front; Rear; Inspection Notes: ALL INSPECTIONS WILL BE DONE BY SPECIAL INSPECTOR FRANK FARLEY SUB -PERMITS Permit # Status PT Cert # DBA Owner / Builder Job Description INSPECTIONS - For Requests, Call: (772) 462-1261 Permit # Code Description Priori Date Sched. Res Description Inspector Date Insp. 0705-0387 133 Window/Door Bucks 1 0705-0387 148 Window/Door Attachment 1 0705-0387 994 Final Engineer Report 1 0705-0387 999 Final Inspection 1 0705-0387 999 Final Inspection 9 ReGONIS13 1,3L302001 Public Worl's St. Lucie County, FL Permit Nur 0705-0387 FARLEY AND ASSOCIATES Consulting Engineers, Inc. 7707 U.S. Highway 1, Suite #3, Vero Beach, Florida 32967 Frank W. Farley P.E. 40111 - E.B. 6641 (772) 589-6229 (772) 589-2296 fax (321)984-9661 (321) 984-9599 fax 26 July 2007 St. Lucie County Building Department Virginia Avenue Ft. Pierce, Florida Ref Window Sliding Glass Door Installation The Sands Unit 405 Dear Sir: As requested by the owner, Polly E. Johnson, the undersigned inspected the installation of the sliding glass doors performed by Florida Awing and Glass at the subject residence. The doors were installed as required by the manufacturer and this office to withstand the design wind pressures required by the 2004 FBC with the 2006 Amendments. Should you have any questions, please feel free to call. I secelveD 31J` 3 0 2007 Public Works gt. Lucie County' Fl- i - L FARLEY AND ASSOCIATES Consulting Engineers, Inc. 7707 U.S. Highway 1, Suite #3, Vero Beach, Florida 32967 Frank W. Farley P.E. 40111 - E.B. 6641 ' (772) 589-6229 (772) 589-2296 fax (321)984-9661 - (321) 984-9599 fax 26 July 2007 St. Lucie County, Building Department Virginia Avenue Ft. Pierce, Florida Ref: Window Sliding Glass Door Installation The Sands Unit 405 Dear Sir: As requested by the owner, Polly E. Johnson, the undersigned inspected the installation of the sliding glass doors performed by Florida Awing and Glass at the subject residence. The doors were installed as required by the manufacturer and this office to withstand the design wind pressures required by the 2004 FBC with the 2006 Amendments. Should you have any questions, please feel free to call. Sincerely, r, s 6 1.:'a FRANK W. FARLEY P.E. 3388 Henderson Drive, Valkaria, Florida 32950 Frank W. Farley P.E. 40111 ' (321) 984-9661 (321) 984-9599 fax 16 May 2007 St. Lucie County Building Department 2300 Virginia Avenue Ft. Pierce, Florida 34982 Reference: Unit 405 The Sands Condominium 3100 N. AIA Ft. Pierce, Florida 34949 Dear Sir: The undersigned has been retained by the owner, Polly E. Johnson, to provide Special Inspection Services (Threshold Inspection) for the replacement of the windows/exterior doors for the referenced project. The undersigned will inspect the work performed by the contractor and upon completion will certify that the work was done in accordance with the permitted plans. Should you have any questions, please feel free to call. Sincerely, Fr PE 401 SI 8 ! ley FIL c.s .E Py ST. LUCIE COUNTY BUILDING DIVISION REVIE7iNNSDP DATE MIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE MIAMM m EMMFMi4MI DARE COUNTY, FLOR DA METRO -DARE R AGLER BUILDING BUII.DING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIMION MIAK FLORMA 33130-1563 .. v..�.J I.i �.)u. �YL .iy✓�✓.r"iiVV NOTICE OF ACCEPTANCE MA) www.builfntrcodeonline com PGT Industries, Inc. 1070 Technology Drive Nokomis, FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in auras other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHD may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance,. if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone_ DESCRIPTION: Series VOMW Aluminum Sliding Glass Doors — L.M.I. APPROVAL DOCUMENT: Drawing No. 4406-1, titled "Alum. Sliding Glass Door, Impact", sheets 1 through 17 of 17, dated 4/15/05 with revision E dated 4/12106, prepared by manufacturer, signed and sealed by Lucas Andrew Turner, P.E., bearing the Miami Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MIssILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the ananuf ichmes. name or logo, city, state and following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the pmfbrmmw of kris product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture ofthe product or process. Misuse of this NOA as an -endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the wards Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. N any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 03-0526.05 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. AML NOA No 06-VM&03 Expiration Date: November 11, 2009 Approval Date: August 3, 2006 Page I T-ff 90OZ `£ Vanv mm PAojddv 69K `TT JaquOMN -joQ uoumdzl £O' ON VON Jet a (�Dd d Ian�Ai22, (LOn90-t0 # NONjapunP4nS) 'a-d `eP dwgjwl opunmpg Aq Palms Puv pouSrs to/SZ/£0 Pape `651V-'M -oK podag wj, `oul `f towjogwj Suw-L uogs.gsauad,fq paaedoid `coop ssgW Smpils mnumtnin us3o meiSetp notrp4sui pun sSumwp dn-po4wtu qjm Suole b6-ZOZ SVJL Pug (q) I'Z'£ I It�Z jUA jod `: s%.L Anud poojod (9 WEOZ SV.L `mod .tad SmM I oinssajd putAA ogoA3 (s b6-IOZ SV.L `Ogg jod Isa,L pvduiI alcssUN aawl (ti t?6-ZOZ SvZ `jgd jad `miL oousr!sag jmsM (£ V6-ZOZ Sd.L `jgd jad SaipsoZ `uojL amssasd .qV ogeiS uuojiutl (Z v6-ZOZ SVZ `3Sd Z uoA$Algul (I uo spodw Iso jL •£ (Longo -to # VojvjapunpawwqnSI g'd `gpsdsmSjn opunutpg Aq Palms Pus pougls `So/I £/lo PajBp `Mt-'IJA W a.todag 490y `•oui `Ajoisjogn•I Sugsay uopnmouod Aq patsdajd `loop sseiS Smplis mnmarnje3° untjSetp uogelisui Pie sSalesBtP do-pa4rem quaSuois tT6-ZOZ SH.L Pug (q) I'Z'£ I ItZ DIU jad `;so L A4uH Poojod (9 V6-£OZ SV.L `3t3d rad SuWe amssaid pm�, otio-(;J (S V6-IOZ SVJL `aSd jod lsaZ aasdmI ollssryq oRwI (b V6-ZOZ SVJL `jUd jad 'ls*Z 00ukqsm-d JMA% (£ b6-7AZ SVZ `a-S—u jad Buqmcq `IsaZ amssaid jV ognS uuo3tufl (Z b6-ZOZ Sd.L `Otld jad `asas uogsmyur jar (I uo suodw 3sas •Z (L07Z9"0 # Vojv-imnPaqw4nS) .2[_d `-Pnd8MSJ I opunmpEIKq polms Pue PauS!s `SO/I Elio Pomp `ysyV-Lyd 'oN:todag Isar `"oul 5koisjogvl Sugsa,L uot:sgsauad Aq paindajd `loop ssgg Suipgs mnuitunis3o m iftip, uotpllo sut pus sSUUAWp do-pa*mm gpm Suole M-£OZ SVJL `OEd jad guq)vo l amssatd pui V6--I0Z SVJL `agd jod v* L aasdun olrsslq aSm7 (Z t,6-ZOZ SVjL ` EU .tad WuWvcr j `Isas amssatd .tV oq%S uuojiufl (I uo spodaj Isar, •I SISIL 'S -a-d `ioutns matpuV seon7 Aq palms pug pains `90/Zl/t, POMP S uoisinat gJIM SO/Si/t, PaxeP `,rajttiasgnusm Aq pomdatd `.,Oeduq `1O°Q sselJ Buq)q " Id» Palms `LI3° LI ggwj% i smlS `T-9ott off 9"'clQ •Z •suogos pug SOU.M jp aip s,.tamloWWW •I S9NMVHG IV (M LUKHaS TJNZQIAN :33xv.Ld3avSo �LLON •auI sat gsnpul and PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 4. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Elroy Test, per FBC 24I 13.2.1(b) and TAS 202-94 along with marked -up drawings and installation diagram of an aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. F77, 4161, dated 03/26/04, signed and sealed by Edmundo Largespada, P.E. (Submitted under NOA # 04-0622. 07) 5. Test reports on 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-4163, dated 03/25/04, signed and sealed by Edmundo Largespada, P.E. (Submitted under NOA # 04-0622. 07) C. CALCULATIONS 1. Anchor Calculations and structur-al analysis, complying with FBC-2004, prepared by manufacturer, dated 5/12/06, signed and sealed by Lucas A. Turner, P.E. Complies with ASTM E1300-98/02 2. Anchor Calculations, and structural analysis, dated 05123/05, and last revised on 07/22/05, prepared, signed and sealed by Lucas A. Turner, P.E., 3. Anchor Calculations and structural analysis, complying with FBC-2004, prepared by PGT Engineering, dated 06/17/04, signed and sealed by Lucas A Turner, P.E. (Submitted under NOA # ".062207) 4. Revised Anchor Calculations, and structural analysis, prepared by PGT Engineering, dated 10/08/04, signed and sealed by Lucas A. Turner, P.E. (Submitted under NOA # 04-0622.07) D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). J Manuel Perez, P G Product Control NOA No Fapirat on Date: November 11, 009 Approval Date: Augad 3, 2006 E-2 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 01-1204.01 issued to E.L DuPont DeNemours, for "Sentry Glass ® Plus" dated 1/17/02, expiring on 1114/07 2. Notice of Acceptance No. 01-0205.02 issued to Solutia, Inc. for "SaflexlKeepsafe Maximum" dated 05/17/01, expiring on 05/21/06. 3. Notice of Acceptance No. 00-1212.04, issued to E.I. DuPont DeNemours for their "Dupont Butacite ® PVB", approved on 02/15/01 and expiring on 12111/05. F. STATEMENTS 1. Statement letters of conformance and "No financial interest", both dated 05/23/05, signed and sealed by Lucas A. Turner, P.E. G. OTHER 1. Notice of Acceptance No. 05-0526.05, issued to PGT Industries, Inc. for their Seriers "SGD-730 Aluminum Sliding Glass Door, approved on 08/25/05 and expiring on 11/11/09. Ma�aoel Product Goitre! Exdwdder NOA No .03 Expiration Date: November 11, 2009 Approval Date: August 3, 2006 E-3 GENERAL NOTES: IMPACT SLIDING GLASS DOOR GLAZING OPTIONS: (SEE DETAILS ON SHEET 2) A. 7/16" LAMI CONSISTING OF (1) LITE OF 3116"ANNEALED GLASS AND (1) LITE OF 3/16' HEAT STRENGTHENED GLASS WITH AN .090 SENTRYGLAS PLUS (SGP) INTERLAYER. TEST REPORTS FTL-4159 AND FTL-4161. B. 7/16" LAMI CONSISTING OF (2) LITES OF 3/16' HEAT STRENGTHENED GLASS WITH AN .090 SENTRYGLAS PLUS IS (SGP) fNTEPLA-YEo TEST REPORT ;'T-415: C. 7116" LAMI CONSISTING OF (1) LITE OF 3116' ANNEALED GLASS AND (1) LITE OF 3/16" HEAT STRENGTHENED GLASS WITH AN .090 PVB INTERLAYER OF DUPONT BUTACITE OR SAFLEX/KEEPSAFE MAXIMUM PVB. TEST REPORT FTL-4171. D. /16' rC�NS1S PING OF' 2)�LITES OF.I3/.18' HEAPSTRENGTFiENEDiGLASS WITH ANC=090 PVBItIVTFJ�LAYER OFiQUPO�iT_6UTACITE OR SAEI EX/KEEP_S . E MAXIMUM•PVB�`TES�REP-ORT�IL"�1i:71. - - - - —=� E.1 1/16" LAMI LG_ CONSISTING OF (1) LITE OF 3116' TEMPERED GLASS OUTSIDE, 7/16' AIR SPACE AND (1) 7/16' LAMI GLASS ASSEMBLY INSIDE. THE 7/16" LAM[ COMPONENT IS ITEM C ABOVE. TEST REPORT FTL-4162. F. 1 1/16' LAMI I.G. CONSISTING OF (1) LITE OF 3/16' TEMPERED GLASS OUTSIDE, 7/16' AIR SPACE AND (1) 7/16- LAMI GLASS ASSEMBLY INSIDE. THE 7116" LAMI COMPONENT IS ITEM D ABOVE. TEST REPORT FTL-4162. G. 9116' LAM[ CONSISTING OF (2) LITES OF 114" HEAT STRENGTHENED GLASS WITH AN .090 SENTRYGLAS PLUS (SGP) INTERLAYER. TEST REPORT FTL-4163. 2. CONFIGURATIONS: SEE DIMENSIONS SHEET 4 AND DIAGRAMS SHEET 5. 3. DESIGN PRESSURES: (SEE TABLES 1 THROUGH 6, SHEET 3) A. NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300-98. B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS TABLES ASTM E 1300-98. C. DESIGN PRESSURES UNDER 40 PSF NOT APPLICABLE IN MIAMI-DADE COUNTY. 4. ANCHORAGE: THE 331/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. FOR ANCHORAGE DETAILS SEE SHEETS 14 THROUGH 17. 5. SHUTTERS ARE NOT REQUIRED. 6. INSTALLATION SCREWS, FRAME AND PANEL CORNERS SEALED WITH NARROW JOINT SEALANT. 7. REFERENCE TEST REPORTS: FTL-4159, FTL-4161, FTL-4162, FTL-4163, FTL-4171, FTL-4454 AND FTL-4524. B. SERIES/MODEL DESIGNATION SGD730, 2-TRACK VERSION ALSO PREVIOUSLY REFERRED TO AS SGD70. NOA DRAWING MAP SHEET GENERAL NOTES ............. 1 GLAZING DETAILS ............ 2 DESIGN PRESSURES....... 3 ELEVATIONS ..................... 4 CONFIGURATIONS........... 5 VERT. SECTIONS ............. 6-8 HORIZ. SECTIONS............ 9-10 PARTS LIST ....................... 11 EXTRUSIONS .................... 12-1; ANCHORAGE .....................14-17 PRODUCT REVISED m cutnnWraQ with the FlmNia 10 TECHNOLOGY DRIVE GENERAL NOTES AND MAP NOKob11%" 3r".' r�"T' P.O. cox 1529 ALUM. SLIDING GLASS DO.OR, IMPACT L .e,j A. T,r:.,, RE NOK0.10.4 r=t 34274 Vi.ihlr 6erav '`""'""` s"11 —' °""°'"'° hE r58201 SGD730 NTS 1 •• 17 4406-1 a E Mechana� EXTERIOR INTERIOR (ALL SECTIONS) 7116" NO 3116" ANNEALED (OPT. A) OR HEAT 090 SENTRYGLAS PLUS INTERLAYER STRENGTHENED GLASS (OPT. B) ` ,: Sfi' I-l�iaT :iRri�fir,i-IvFI :I ucc 1 1 46 39 or 55 49 591 NOM. GLASS BITE 1 1/16' NOM. 3/16" ANNEALED (OPT. E) OR HEAT _4 1 STRENGTHENED GLASS (OPT.F) AIR SPACE I I "1` I 1"'T •VGVFV5INTERu1fERISEENWE) 3116" TEMPERED GLASS --� �7 I _ 3/16' HEAT STRENGTHENED GLASS 47 ( 42 or 43 51 --! 591 NOM. GLASS BITE 7=::i t 1644 or 45 44 or 45 52 1 1/16" LAMI I.G. GLASS 52 GLAZING OPTIONS A & B GLAZING OPTIONS E & F NOTE: PVB INTERLAYER IS DUPONT BUTACITE OR SAFLEXIKEEPSAFE MAXIMUM. 7116" NOM. 9/16" NOM. 090" PVB INTERLAYER (SEE NOTE) .090 SENTRYGLAS PLUS 3/16' ANNEALED (OPT. C) OR HEAT 1/4" HEAT STRENGTHENED GLASS INTERLAYER STRENGTHENED GLASS (OPT. D) 3/16" HEAT STRENGTHENED GLASS 1/4" HEAT STRENGTHENED GLASS 46 40 or 41 46 56 PRODUCTREVISED 49 o.6>cr Cc wim ma r a: 57 eD:a>Qa z� Ascsn�wtJ o3 59 NOM. 59i NOM. r'c;�Ir;ticuL�ru Og GLASS BITE GLASS BITE Dmk_ �_tct 16 16 em n 44 or 45 44 or 45 /JMI�CL1SS� �i Bad 9/16" LAMI GLASS (SGP) 52 ,. 52 �- GLAZING OPTIONS C & D GLAZING OPTION G aswI D REMOVE L4Ml /.G. AIRSPACE DIAL. NOKOWS. FL 34275 "ff—r� "`� ' �.. ALUM. SLIDING GLASS DOOR, IMPACT 1011,64 C a00 GLOSS TYPE G. 9116"LAME P.O. BOX 1529 Luc65 A ruueer. RE Br Oan: NOXOM!S. FL 34274' V(tib& Better — s"i° �°"" "" PE #58201 Snaro4 ,.r. 4 rS65 SG0730 FUL 2 17 4406-i E Mechamuy CONFIGURATION OVERALL WIDTH IN INCHES MAX. NOM. PANEL WIDTH >1 48" 60" MAX. HEIGHT> 120" 96" 8 CONFIGURATION PANELS TRACKS WIDTH WIDTH 1 Xp OR pX 1 2 49 118 61 1/8 2 OX or XO BY-PASS 2 2 9613116 1M 1 1116 3 pXXp 2 2 10 11/8 125 1/8 4 XX BY-PASS 2 2 9613/16 IlZq 13/16 5 6 DXX orXXp XOX BY-PASS 2 3 9 2 gg 1/e I 1?n 144 180 7 000 3 2 1144 180 8 OXO BY-PASS 3 2 1149 3/8 185 3/8 9 pXXO or OXXp 3 2 148 13/16 184 13/16 10 OXX or XXO BY-PASS 3 2 149 318 135 3/8 11 OOX or XOO BY-PASS 3 3 144 180 12 OXX or XXO BY-PASS 3 3 144 180 13 XXX BY-PASS 3 3 144 1180 14 pXXX or XXXp 3 3 143 7/16 179 7/16 15 OXX or XXO BY-PASS 3 2 , 149 3/8 185 318 16 0000 4 2 196 9116 244 9/16 17 OXXO BY-PASS 4 2 196 9/16 244 9/16 18 OXXXp or pXXXO 4 2 198 244 191 pXXXXorXXXXpBY-PASS 4 2 1196 244 20 XXXX BY-PASS 4 2 196 9/16 244 9/16 21 pXXxXp 4 2 195 1/2 243 1/2 22 OOOX or X000 BY-PASS 4 4 19 33116 239 3/16 23 OOXX or XXOO BY-PASS 4 4 191 3116 239 3116 24 OXXX or XXXO BY-PASS 4 4 191 3/16 239 3/16 25 XXXX BY-PASS 4 4 191 3116 239 3/16 26 pXXXX or XXXXp 4 4 190 518 238 518 27 XXXXX BY-PASS 5 3 1243 3/4 303 3/4 28 5x—xxxxxp 6 3 128913116 36113116 29 XXXXXX BY-PASS 6 3 29015/16 362 15/16 30 . pXXXXXXXXp 8 4 139 3/16 480 3116 31 XXXXXXXX 8 4 1385 114 481 114 FIXED PANEL CLIP (ITEM 18) LOCATIONS, ITYP. ON ALL FIXED PANEL SIDE RAILS •. I uL I �,, ; , POCKET II H{ lH �" Br JB 1 MAX, WIDTH _ I� MAX. WIDTH (TABLE 8) 1 (TABLE 8) XXp OR pXX E[" 'E I POCKET I a D1 f III -D jj��391/4" TYtP. I TABLE 8. (LOWER CASE p REPRESENTS POCKET INSTEAD OF JAMB) --L MAX. WIDTH (TABLE 8) DLO, SEE NOTE 6 F F n A[JA I Al SEE SEE NOTE 5 NOTE a Gr lG � Hf �H SEE NOTE 7 �— MAX. WIDTH (TABLE 8) OXO r C IN I D C SOCKET <3 a B� JB Hr lH �+--- MAX. WIDTH (TABLE 8) — — NOTES: Xp OR Xp pXXXO OR OXXXp 1. FOR VERTICAL SECTION DETAILS SEE SHEETS 6, 7 AND 8. FOR HORIZONTAL SECTION DETAILS SEE SHEETS 9 AND 10. 2. FOR APPROVED CONFIGURATIONS SEE SHEET 5. 3. FOR ANCHORAGE DETAILS SEE SHEETS 14 THROUGH 17. 4. MAXIMUM HEIGHT FOR DOORS WITH UP TO 4 FT. (48') WIDE PANELS IS 10 FT. (120'). MAXIMUM HEIGHT FOR DOORS WITH UP TO 5 FT. (60-) WIDE PANELS IS 8 FT. (96'). SEE -TABLE 8 FOR OVERALL WIDTHS OF APPROVED CONFIGURATIONS. 5. VERTICAL DAYLIGHT OPENING FOR 10 FT. HIGH (120') DOORS IS 112 3/4- MAX. AND FOR 8 FT. HIGH (96') DOORS IS 88 3/4' MAX. (DOOR HEIGHT - 7114'), 6. HORIZONTAL DAYLIGHT OPENING FOR 5 FT. (60-) WIDE PANELS IS 55 7116" MAX. AND FOR 4 FT. (46") WIDE PANELS IS 43 7116• MAX. (NOM- WIDTH - 4 9116'). 7. FIXED PANEL ANGLE BRACKETS (ITEM 54) LOCATED AT THE HEAD AND SILL OF ALL FIXED PANEL INTERLOCKS, SEE SHEET 10 FOR DETAIL VIEW. IW/06 1070 TECHNOLOGY DRIVE EXAMPLE ELEVATIONS&COA NOKOMIS. FL 34275 ra P.O. eox 1529 ALUM. SLIDING GLASS E NOKOMIS. FL 34274 Wvibly Better 5—" S"` &'°" SGO730 NT$ 4 - 17 IMPACT 4406-1 PRODUCT SZr : i2.L 8:7 iz-6-.3 i'd'ylm.:i.-' .Y.; -. 03 NOV_ -c09 rat:.-• :a1 7" - . ,�- � -�% Lucas A. Turner. P.E. PE #58201 Mechanical ASTRAGAL SIDE RAIL PMDUCT REVISED eS eumr'it'i09 al",lt Mt- F'A ios UvfCtDn ode — EXTERIOR INTERIOR _7L (ALL SECTIONS) TYP. VERTICAL SECTION SHOWING ONE TYP VERTICAL SECTION SHOWING ACTIVE PANEL AND ONE FIXED PANEL TWO ACTIVE PANELS t rt2N5 E NoctwNGETHIS SHEET 1070 TECHNOVERTICAL SECTIONS, ORIGINAL 2 TRACK R°11eo'•'OGY ORfVE W05 D ADD STANDARD AND OPTIONAL S&L RISER HEIGHT DIM NOKOMIS. Ll..1115 — Draw R' No CHANGE TwS SHEET P.O. BOX T529 ALUM. SLIDING GLASS DOOR, IMPACT L•.I A Tu,mr. P E. cn .Y uW NOKOMIS. FL 34274 Visibly Better s.�siw.t s"` srr.� °G�'p NO R" PE #58201 IW4 JJ 411 SGO730 112 6 - i7 1 4406-1 F •-' S, 58J59, LOCATED AT VERTICAL 60 O25 18 CENTER, 12" FROM TOP AND BOTTOM OF FIXED PANELS REINFORCEMENTS 42 27 GLASS TYPES A. B REQ'D W/ OR G ONLY (3) REQ'D X 60 or 69 8, 66, 67, ^ O ITEM 68 SHOWN X 10 25 11 Si S,S21 or S24 — — — — — — — — — — — — — — ITEM S24 SHOWN SECT. A -A SECT. B-B ONBL A '�SINGLEAINTERL( 90% SECT. D-D MOVABLE INTERLOCK AT P-HOOK A ITEM 68 SHOWN A ITEM S24 SHOWN INFORCEMENTS REQ'D WI ASS TYPES A, B OR G ONLY "" - SECT. E-E MOVABLE TO MOVABLE ASTRAGAL (INSIDE SHOWN) MOVABLE STILE AT .IAMB (INSIDE) 0 E ADD ITEMS 69AND 71. ALTERrurE 2 rRACK FRAME WISCREEN PAIL f07J4DR5IVE HORIZONTAL SECTIONS O"ADO7ANDaTRACKOPTIONSANOGLASSYPEGYY'REINF NOKOMIS.. R T� P.O. BOX 1529 ALUM. SLIDING GLASS DOOR, IMPACT C NO CHANGE fHtS SHEET cKaraer Due NOKOMIS, FL 34274 Visibly Better s`"" s..r 1/2 9 d 17 4406-1 59 ,& 4. INTERIOR (ALL SECTIONS) EXTERIOR PRODIrCr RE VISnED as tort}Xy.'og with Slip Had& BW tgCoda Accen-,..oxi'I0 L'- l' bunni Prodaw C--1 1! o Lucas A Turner. P.E. PE 058201 Mechanical HEAD AND SILL INTERLOCK & ASTRAGAL ANCHOR A. 7/16 LAMI (A, .090 SGP, H) B. 7/16 LAMI (H..090 SGP, H) CLUSTER BY PANEL SIZE & GLASS TYPE C. OR E. 7116 LAMI (A.H) OR IN 1 1116 LAMI I.G G 9116" LAMI D. OR F. 7116 LAMI (H.H) OR IN 1 1116 LAMI I.G. (H..090 SGP, H) ANCHOR TYPE DOOR HEIGHT 8 SUBSTRATE �•_, 72" (6p) 80" W) 840 (7p) 90" IA 96' Iasi 102" IR4 108' 0) 114- (96) 12(r (10p) pp gg v z" VT mo •Qp❑ pZ o QO p Z QO Z 0 Qp Z Q Q $ U $ U Q 3 U Q ONOM. O wiO Nn+_ INK �fy n I I rMN� GL4AB J Q J Q J Q J Q J_ ¢ Q J Q Q Q J Q J Q J Q ��11 J J Q JJWIDTHuW� J QJO S rnS m= y 2vJ 2y _ _� = _ to =• 4J =fD (D y24"(2) -8 A A B B 8 A C A C B B A C B B A C B B A C B B A C 8 8 B C B C,D 8 B A C B B A C B C C8 8 C C(Z) B 8 A C 8 B A C $8B g C C B g C C B B C B B B C C B B C C B B D C C,D B B A C 8 B A C B C C 8 8 C C p A,B,C,E B A C 8 B B C 8 B 8 C C B 8' O C B B D C B B C C B B O C C B D C C B D C 13) n Fr. R R r. r. R R n r R R n 47 (35 B JBIAIC B D,F,G JBIBIC C 46• (4p) A,C,E JA A B 8 8 1 B B C —co D,F,G 8 B C 54•(46) A B,G 6w (e) A ftAB B,G PPROVED ANCHORS: 1. ELCO IW IAMI-OADE COUNTY ANCH( (2) ANCHORS REQUIRED E (1) ANCHOR REQUIRED_Ai ;ILL AND JAMB LOCATION. LOCATION. ANCHOR LOCATIONS TO BE STAGGERED. INTERLOCK OR h — ASTRAGAL CL I._ WF D1F CLUSTER A - (4) ANCHORS INTERLOCK OR �— ASTRAGAL CL FF 81s" - BA" ;I CLUSTER C - (8) ANCHORS INTERLOCK O I`--' ASTRAGAL CL CLUSTER B - (6) ANCHORS INTERLOCK OI (--- ASTRAGAL CL _.� 3" 3" CLUSTER D - (10) ANCHORS INTERLOCK OR 3• ASTRAGAL CL - 4 3" 1 3' I �- NOTE: 83/16' DIMENSION IS MAX. AND 3" — — — + — — — O.C. IS MIN. 1--8k -1 8&" -•1 FOR ALL CLUSTER E - (12) ANCHORS CLUSTERS - JAMBS "' $iM9X1FRONl?8'OTCOM:AND 24' MAX. .C_ FORy1/4' TAPCONS O . CRETE-F(± E�(s16"'MAX:+. u - O C..FOR�71`i2 SCREWS: P-HOOKS....... 8" MAX. FROM BOTTOM AND 15" MAX. O.C. FOR 1/4' TAPCONS, CRE E=FL'EXIOR SCREWS. 3. MAX. 120' HIGH DOORS W/ PANELS UP TO 48" WIDE. HEAD & SILL.. 81/4' MAX. FROM CORNERS AND APPLICABLE CLUSTERS) FROM TABLE 7 AT EACH ASTRAGAL AND INTERLOCK CENTERLINE. 16 3/8' MAX. O.C. (1/4• TAPCONS, CRETE-FLEX OR #12 SCREWS. JAMBS ............ 8" MAX FROM BOTTOM AND 26" MAX. O.C. FOR 1/4' TAPCONS OR CRETE-FLEX. 22" MAX. O.C. FOR #12 SCREWS. P-HOOKS.....-. 8' MAX. FROM BOTTOM AND 201/4' MAX. O.C. FOR 1/4" TAPCONS, CRETE-FLEX OR #12 SCREWS. 4. MAX. 96' HIGH DOORS W/ PANELS UP TO 60' WIDE. HEAD & SILL.- 81/4' MAX. FROM CORNERS AND APPLICABLE CLUSTER(S) FROM TABLE 7 AT EACH ASTRAGAL AND INTERLOCK CENTERLINE. 2213116" MAX. O.C. FOR 1/4' TAPCONS OR CRETE-FLEX. 15 3/8" MAX. O.C. FOR #12 SCREWS. JAMBS ............ 8" MAX FROM BOTTOM AND 22" MAX. O.C. FOR 1/4" TAPCONS OR CRETE-FLEX 15" MAX. O.C. FOR #12 SCREWS. P-HOOKS....... 8" MAX. FROM BOTTOM AND 13 718" MAX. O.C. FOR 1/4" TAPCONS, CRETE-FLEX OR #12 SCREWS. ANCHORAGE SPACING FOR DOORS INSTALLED OUTSIDE MIAMI-DADS COUNTY: 5. MAX. 96" HIGH DOORS W/ PANELS UP TO 48" WIDE - HEAD & SILL........... 8 1/4" MAX. FROM CORNERS AND CLUSTER A, AT EACH HEAD AND SILL ASTRAGAL AND INTERLOCK CENTERLINE. 16 3/8" MAX. O.C. JAMB..... 8" MAX FROM BOTTOM AND 2611/16" MAX. O.C. P-HOOK..... 8" MAX FROM BOTTOM AND 15" MAX. O.0 S. MAX. 120" HIGH DOORS W/ PANELS UP TO 48" WIDE. HEAD & SILL........... 81/4" MAX. FROM CORNERS AND CLUSTER A, AT EACH HEAD AND SILL ASTRAGAL AND INTERLOCK CENTERLINE. 16 318" MAX. O.C. JAMB...-. 8' MAX FROM BOTTOM AND 26' MAX. O.C. P-HOOK..... 8" MAX FROM BOTTOM AND 20 1/4" MAX. O.0 F. MAX 96" HIGH DOORS W/ PANELS UP TO 60" WIDE. HEAD & SILL.--...-.... 8 1/4' MAX. FROM CORNERS AND CLUSTER A, AT EACH HEAD AND SILL ASTRAGAL AND INTERLOCK CENTERLINE. 22 13/16- MAX. O.C. . JAMB..... B" MAX FROM BOTTOM AND 26 11116" MAX. O.C. P-HOOK..... W MAX FROM BOTTOM AND 13 7/8' MAX. O.0 r..saer wl. rae.em,. F"t "i° IDTOTECNN060GYDR+VE Fr4rS'!IS D CONDENSE 7A8tE 7 AlYD UF`GRAOE ANCHORgIiE PER F8C 2(Yu NOKOM1tIS. FL 17775 "°8' ALUM- SLIDING GLASS DOOR, IMPACT FJC 1.0 RECALCNVCHOH GIPAG7IES, UPDATE SPAGNG NOTESAND TAB[E P.D BOX Mg ALUM. Sty Dn�vw ..net oan cnc �"ae flare NOKOMIS. Ft 34274 V;x1h& Better F.K 611&V4 JJ alsas sGDT3o 1/8 74 - 17 1 4406-1 EXTERIOR (ALL) 15 PRODUCTRMSED e9 eomPlyLeg with the F7bri& Baidin Code Aa-�IaceNo - O 83' PtmI1M ffc-l-, DLi, i I , , n Tweet. P E. " P458201 E MEP.�'m.lica1 < ] EXTERIOR INTERIOR - (CONCRETE) (ALL SECTIONS) :5 •T .. 1 1/4" :U MIN. I WOOD BUCK - SEE NOTE 2 I 114" 114" pp I I I MAA. SHIM MAX. Y 1/4" TAPCON, SEE NOTE 1 ® #12 SCREW, SEE NOTE 5 BUCK NOTE 2 SEE NOTE 1 NOTES: 1. MIN. DISTANCE FROM CONCRETE ANCHOR TO CONCRETE EDGE IS 2 112' FOR HEAD 2x WOOD A SILL AND JAMB AND 1" FOR P-HOOK INSTALLATION. FOR CONCRETE APPLICATIONS I SEE NOTE 2 MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED ELCO 1/4" TAPCOP OR 114" ELCO SS4 CRETE-FLEX ANCHORS. FLAT HEADS TO BE #12 TRIMFIT TYPE. 2. WOOD BUCKS DEPICTED AS I ARE LESS THAN 1 1/2" THICK. lx WOOD BUCKS ARE 1 112" OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE. WOOD BUCKS MIN. DEPICTED AS 2x ARE 1 1/2" THICK OR GREATER. INSTALLATION TO THE SUBSTRATE OF WOOD BUCKS TO BE ENGINEERED BY OTHERS OR AS APPROVED BY THE T , " ,ny n11THOR!Tv H.AVINC- JLIR!SCICTiC": %AHJ). SHIM J. FOR ATTACHMENT TO ALUMINUM: THE ALUMINUM SHALL BE A MINIMUM STRENGTH J OF 6063 T5 AND A MINIMUM OF 1/8" THICK. THE ALUMINUM STRUCTURAL MEMBER SHALL BE OF A SIZE TO PROVIDE FULL SUPPORT TO THE DOOR FRAME SIMILAR TO THAT SHOWN IN THE DETAILS ON SHEETS 15 16 AND 17 FOR 2x WOOD BUCKS THE FRAME HEAD INSTALLATIONS ANCHORS SHALL BE #12 SHEET METAL SCREWS WITH FULL THREAD ENGAGEMENT T_1 j4" MAX! SCREEN SHIu / FRAME INTO THE ALUMINUM. IF THESE CRITERIA ARE MET, THE PRESSURES SHOWN ON 2x WOOD SHEET 3 AND ANCHORAGE SPACING FOR 412 SCREWS SHOWN ON SHEET 14 MAY SEE NOTE 2 BE USED. 4. SCREEN FRAME AND DOOR FRAME MAY BE ATTACHED TO DIFFERENT SUBSTRATE TYPES AS REQUIRED TO ACCOMMODATE THE EXTRA DEPTH OF MULTI -TRACK _ 1 1/2" CONFIGURATIONS, AS APPROVED BY AHJ. DESIGN OF COMPOSITE WOOD/MASONRY MIN MID OPENINGS DONE BY OTHERS OR AS ACCEPTED BY AHJ. FASTENER SIZE, EMBEDMENT, AND SPACING MUST BE AS INDICATED FOR THE SUBSTRATE INTO 11 "MAX- WHICH THE FASTNER IS EMBEDED. SHIM 5. FOR WOOD APPLICATIONS ELCO 1/4' TAPCONS OR 1/4" SS4 CRETE-FLEX ANCHORS A WITH #12 TRIMFIT HEADS MAY BE USED INSTEAD OF #12 SCREWS. SEE TABLE 7. #12 SCREW, SEE NOTE 5 ALTERNATE 2 TRAC'KOFRAME-- ® W/ SCREEN RAIL (CONCRETE) 11/4 lx WOOD BUCK 1 MIN. SEE NOTE 2 SCREEN FRAME ! T—1/4" MAX. L SHIM SCREEN FRAME 1/4" TAPCON, SEE NOTE 1 3—TRACK FRAME HEAD INSTALLATIONS (CONCRETE) f 1 1/4" I WOOD BUCK - MIN. SEE NOTE 2 SCREEN FRAME 114" MAX. SCREEN I~! 1 SHIM FRAME ti ti fi 114" TAPCON, SEE NOTE 1 4—TRACK FRAME HEAD INSTALLATIONS 2x WOOD SEE NOTE 2 1 1/2" MIN. L 1/4" MAX. SHIM #12 SCREW, SEE NOTE 5 A 2x WOOD SEE NOTE 2 - - 1 112" -_ MIN. 1/4" MAX. SHIM #12 SCREW, SEE NOTE 5 A 1070 TECHNOLOGY DRIVE =1 ANCHORAGE DETAILS, HEAD 3 A 4-TRACK AND ALTERNATE? -TRACK OPTIONS NOKOMIS. FL 34275 »t E 1 P.U. 80X 1529Inic.-ri ALUM. SLIDING GLASS DOOR NOKOMIS FL 34274 Vi..dh& Better "" scw s °ir" sc0730 1/4 15 v 17 4406-1 PRO01A If REi'SS€T 3s c 9c;A':iva wtfh9SC Rarxit c'g itiM„ C:Ks nnc fi.{;at2: a is PmeS9'_t (�nsi. of L.;aS P.. 'fuMPI- P.E. PE 058201 Mechanical 1 1/2" MIN. #12 SCREW SEE NOTE 5. 2x WOOD SHEET 15 r — SEE NOTE 2 SHT. 15 �I 1/4" MAX. SHIM — �{ 1x WOOD BUCK 1 1/4' MIN. SEE NOTE 2 SHT. 15 1 /4" TAPCON SEE NOTE 1 SHT. 15 (CONCRETE) tiv, 114' SHIM MAX —�I i"- ORIGINAL 2-TRACK FRAME JAMB INSTALLATIONS 1xWOOD BUCK SEE NOTE 2 SHT. 15 'II 1%4' TAPCON SEE NOTE 1 SHT. 15 1 SCREEN _ _�� FRAME 1/4" SHIM MAX- 1 1/4" MIN. '(CONCRETE) 1 1/2' MIN. #12 SCREW SEE NOTE 5. ® SHEET 15 2x WOOD i SEE NOTE 2 SHT. 15 SCREEN FRAME 1/4' MAX. SHIM --i F- _. til 1 1/4" MIN. EE NOTE 2 , o A4- SHT.15 ti 2 TRACK FRAME ' W/ SCREEN RAIL 1/4' TAPCON SEE NOTE 1 --� SHT. 15 1/4" SHIM MAX. —+{ 1 1/2" MIN. #12 SCREW SEE NOTE 5, ® SHEET 15 1 I 2x WOOD SEE NOTE 2 SHT. 15 SCREEN FRAME 1/4' SHIM MAX. 3-TRACK FRAME JAMB INSTALLATIONS 5 'p TECHNOLOGY OR NOKOMIS. FL 34275 P.U. BOX 1529 NOKOMIS. FL 34274 I+ 1 112" MIN. #12 SCREW SEE NOTE 5. 2x WOOD ® SHEET 15 SEE NOTE 2 SHT. 15 i' i SCREEN FRAME " , 1/4" SHIM MAX. ---I {----- 1x WOOD BUCK SEE NOTE 2 SHT. 15 1/4' TAPCON SEE NOTE 1 SHT. 15 ■1 i SCREEN FRAME 1/4' SHIM MAX. —� { �—• 1 1/4" MIN. ,r. (CONCRETE) ,4 4-TRACK FRAME JAMB INSTALLATIONS ANCHORAGE DETAILS, JAMB M ALUM. SLIDING GLASS DOOR, IMPACT sn.an�n swr si..r aw.yw SGO730 114 1 16 . 17 4406-1 L^a u INTERIOR (ALL SECTIONS) EXTERIOR ID PRODUCT REVISED a cum*bq witts ft Awids AAoceptzam No O� - man, *9ietal a Ptidect Coates! Lug"s A '.umr, P.E PE #58201 McChanical EXTENDED SILL (3112" ), MAX. 96- (S") HIGH DOOR. TABLE ALL CONFIGURATIONS WITH A MAX. NOW PANEL WIDTH OF 60" (5°) GLASS TYPE A. 7/16" LAMI (3/16" ANN... 090 SGP, 3/16" HS) FTL-415 om. Panel Door Height Width 72" (6°1 80" (6e) 84" (70) 90" (76) 30" (2`� 36" (39) +70.0 +70.0 -70.0 1 -70.0 1 +70.0 +70.0 -70.0 -70.0 1 +70.0 +70.0 -70.0 -70.0 1 +70.0 +66.8 1 -70.0 1 +70 0 1 -70 0 66.8 +64.8 64.8 42" (3B) +62.6 -62.6 +56.7 -56.7 +53.9 -53.9 1 +50.7 -50.7 +48.2 48.2 44" (40) +53.2 -53.2 +47.2 47.2 +44.4 -44.4 +42.3 -42.3 +40.6 -40.6 54"(4) +46.2 -46.2 +41.3 41.31 +39.4 -39A +37.1 -37.1 +34.6 -34.6 60" (5) +41.7 i -41.7 +37.6 -37.6 +35.8 -35.8 1 +33.1 -33.1 +30.9 -30.9 EXTENDED SILL (3112% MAX. 96" (8) HIGH DOOR. TABLE 2A. L SIZES AND CONFIGURATIONS WITH A MAX. NOM. PANEL WIDTH OF 60" (5°) GLASS TYPE G. 9/16" LAMI (1/4" HS,.090 SGP, 1/4" HS) FTL-4163 +70.0 I -70.0 EXTENDED SILL (3 1/2"), MAX. 96" (8) HIGH DOOR. TABLE S. ALL CONFIGURATIONS WITH A MAX. NOM. PANEL WIDTH OF 48" (4) GLASS TYPEC. 7/16" LAMI (3/16" ANN...090 PVB, 3/16" HS) FTL-4171 GLASS TYPE E. 1 1116" LAMI LG W/ 7/16" LAMI TYPE C. FTL-4162 (3/16" TEMP., 7116" AIR SPACE, 3/16" ANN.,.090 PVB, 3/16" HS) om. Daccr Height ranei Width 72" (6) 80' (6) 84" (70) 1 90" (7B) 96" (8°) 30" (2) +80.0 -80.0 +80.0 -80.0 +80.0 -80.0 +80.0 -80.0 +80.0 -80.0 36" (3°) +76.6 -76.6 +72.7 72.7 +70.6. -70.6 +66.8 -66.8 +64.8 -64.8 42" (3e) +62.6 -62.6 +56.7 -56.7 +53.9 -53.9 +50.7 -50.7 +48.2 -48.2 48" (4°) +53.2 -53.2 +47.2 -47.2 +44.4 -44.4 +42.3 -42.3 +40.6 -40.6 EXTENDED SILL (3 1/2"), MAX. 96" (8°) HIGH DOOR. TABLE 6. ALL SIZES AND CONFIGURATIONS WITH A MAX. NOM. PANEL WIDTH OF 48" (40) GLASS TYPED. 7116" LAMI (3/IW HS,.090 PVB, 3/16" HS) FTL-4111 +80 0 -80.0 GLASS T'YPEF. 1 1/16" LAMI I.G W/ 7/16" LAMI TYPE D. FTL-4162 +80.0 1 -80.0 (3/16" TEMP., 7/16" AIR SPACE, 3/16" HS490 PVB, 3/16" HS) EXTENDED SILL (31/2% MAX. 120" (100) HIGH DOOR. 4LELL SIZES AND CONFIGURATIONS WITH A MAX. NOM. PANEL WIDTHOF 48GLASS TYPE B. 7/16" LAMI (3/16" HS,.090 SGP, 3/16" HS) FTL-4161 +60. EXTENDED SILL (3 1/2"), MAX. 120" (10) HIGH DOOR. ALL CONFIGURATIONS WITH A MAX. NOM. PANEL WIDTH OF 48- (4°) GLASS TYPE A. 7/16" LAW (3116- ANN.,.090 SGP, 3/16" HS) TABLE 3. FTL-4161 Nam. Panel Door Height Width 72" (fiq 80" (6) 84" (7) 1 SW (7e) 96" (8) 102" (8) 108" (9q 114' (9) 120" (10) 30' (2) +60.0 1 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 1 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 36" (3) +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 60.0 4.60.j 60.0 +60.0 -60.0 +58.9 -58.9 +58.2 -58.2 42" (36) +60.0 -60.0 +56.7 -56.7 +53.9 -53.9 +50.7 -50.7 +48.2 -48.2 +46.46.3 +44.6 -44.6 +43.4 -43.4 +42.1 -42.1 48" (q) +53.2 -53.2 +47.2 -47.2 +44.4 -44.4 +42.3 -42.3 +40.6 -40.6 +38.38.3 +36.0 -36.0 NOTES: REVISED x pidi the f inri4L, 1. POSITIVE DESIGN PRESSURE IS LIMITED TO +40.0 PSF FOR ALL SIZES AND CONFIGURATIONS NOT EQUIPPED WITH 31/2' EXTENDED SILL RISER. NEGATIVE PRESSURES ARE NOT CHANGED. SEE VERTICAL SECTIONS, SHEETS 6 THROUGH 8 FOR EXACT SILL HEIGHTS. J 2. REINFORCEMENTS NOT REQUIRED IN DOOR PANELS WITH GLASS TYPES C, D, E AND F (TABLES 5 AND 6). REINFORCEMENTS ARE REQUIRED IN DOOR PANELS WITH } i ; ; ✓ 6: GLASS TYPES A, B AND G (TABLES 1, 2, 2A, 3 AND 4). TABLE 1077ECHNOLOGE 4Z75 NOKOAi1S. F( 3J275 P.O. BOX 1529 NOXOMIS. FL 342?4 1 I/jSj,4 v Ber(e-r DESIGN PRESSURES KUM. SLIDING GLASS DOOR, IMPACT spar sneer Lucas A V.E. PE p58201 58201 sco?3o FUL 3 - 17 � 4406-1 �E I Mein+cai SCREEN & #12 SCREW, FRAME SEE NOTE 5, SHT 15 1/4' MAX. SEE I 112"MIN. E NOTE 1 2-x WOOD SCREEN SHT. 15 FRAME 1/4"TAPCON 1/4' MAX. SEE NOTE 1 SEE NOTE I SHT. 15 114!MIN. (CONCRETE) 4-TRACK-FRAME SILL INSTALLATIONS A ANCHORS ARE STAGGERED 1' MIN. AT P-HOOK ANCHOR EMBEDMENT AT P-HOOK' 1/4"TAPCON -I 1/4" MIN. 114" CRETE-FLEX -1 314" MIN. Ix WOOD BUCK (CONCRETE) SEE NOTE 2 (CONCRETE) 1 1/4" MIN. 3/8'M 1 114" SHT. 15 3/8"MIN.-I IN.MIN., 1/4' TAPCON T (SEE NOTE 1) SHT.15 101 INTERIOR (ALL P-HOOK SECTIONS) EXTERIOR lu & #12 SCREW. SEE NOTE 5, SHT 15 SCREEN FRAME 1/4" MAX. 1 1/2" MIN. SEE NOTE 1 9v WOOD SEE NOTE 2 & - #12 SCREW, SEE NOTE 5, SHT4 SCREEN FRAME 1/4' MAX. t2" MIN, SEE NOTE 1 ,x WOOD SCREEN SHT. 15 FRAME -%SEE NOTE 114"TAPCON 1/4'TAPCON S 15 KT�Q, 1/4" MAX. SEE NOTE 1 1/4*1 SEE NOTE 1 SEE NOTE I SHT. 15 SE 4 TE1 SHY. 15 1114"MIN. • 1114' MIN. (CONCRETE) (CONCRETE) SM 3JRACK FRAME SILL INSTALLATIONS E; R � E ,&ALTERNATE 2 TRACK FRAME W1 SCREEN RAILS-MONSWAOMMI NS'_/ EXTERIOR INTERIOR (ALL SILL SECTIONS) 3/8' MIN.—� T 1'1/4"TAPCON #12 SCREW T (SEE NOTE 1) SEE NOTE 5 SHT . A SHT. 1� . I 5 TYPICAL POCKET P-HOOK INSTALLATIONS #12 SCREW, SEE NOTE 5, SHT. 15 I I - I 1/2"MIN. 114- MAX. 1 112" MIN. SEE NOTE 1 2 2x WOOD x WOOD SEE NOTE 2 SEE NOTE 2 —4 SHT. 15 SHT. 15 1/4!TAPCON SEE NOTE I SHT. 15 1/4"M SEE NOTE 1/4' MIN. (CONCRETE) E) ORIGINAL 2-TRACK FRAME SILL INSTALLATIONS NOTE: 1. IF SILL IS TIGHT TO SUBSTRATE, GROUT OR OTHER MATERIAL IS NOT REQUIRED. IF USED, GROUT OR OTHER MAIL (DONE BY OTHERS) MUST FULLY SUPPORT THE ENTIRE LENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE. AND TRANSFER SHEAR LOAD TO SUBSTRATE. ALTERMTE2 TRACK FRAME WISCREEN RAIL AND P-HOOK CHANGE. 1070 TECHNOLOGY DRIVE ANCHORAGE DETAILS, SILL & POCKET P-HOOI 13 4-TRACK AL TURNAT62-TRACK OPTIONS AND GROUT NOTE NOKOMIS FL 34275 rm 4ANGE TSHEET P.U.P.. 60,1( 1529 ALUM: SLIDING GLASS DOOR, IMPACT - - J - 1w__ - lR_ NOKOMIS. FL 34274 vixib�y Bvru� I SGD730 114 1' 17 - 17 4406-1 E PRODL;C"T REVISED L"151 %. Tilmer. RE Pt 1158201 Me haWcal 8.038 = 6.130 -� I 4.222 -�-j ill--i 494 r r �r,� �� 078 I ji f 11 i 2.625 076 1 i 625 078 �. I 2 625 } 1 E 2.713 .078 rR . Q TRAr.W Cu 1 2 T R ACI" SILL 6 i - o I ANFiAKU 6iLL ikiSE < MATL: 6063-T6 MAT'L: 6063-T6 MATL: 6063-T6 MATL: 6063-T6 DWG# 4407 DWG# 4408 DWG# 4409 DWG# 4410 _494 3.500 .078 -- -i I. rl 62 - 3.50" SILL RISER MAT'L: 6063 T6 DWG# 4411 8.038 -y� 6,130 �-1 r- 4.222 8.038 1 �-- 6.130 1 dkJl_I�JL�cti�jn a r��--�-,uv� fls �l�I 1.619 U u� �1.619 I1 }! ��U�U 1.235 1� --}n 1.235 l �I ��)---at_- 111 11r .018 --�°r 1 .078 --��- I o78 --��- 1.619 078 ,078 ---�� - 63 - 4 TRACK HEAD MAT'L: 6063-T6 DWG# 4412 f+- 4.222 ---1 1 1.235 68 - 2 TRACK JAMB MATL: 6063-T6 DWG# 4417 0 2.646 i•-•- 1.619 rr F-- 4ll a - .o78 S21 - SCREEN 2 TRACK FRAME JAMB MAT'L: 6063-T6 DWG# 4423 64 - 3 TRACK HEAD 65 - 2 TRACK HEAD MAIL: 6063-T6 MATL: 6063-T6 DWG# 4413 DWG# 4414 3.810 -�-•I A LI; -�11 .078 S16 - SCREEN 3 TRACK FRAME SILL MATL: 606346 DWG# 4418 -�-{ 1.283 I .810 .078 -y III S22 - SCREEN 1 TRACK FRAME SILL MATL: 6063-T6 DWG# 4424 Fes- 5,505 -�I� 1.619 .078F- 70 - FRAME, 2 TRACK HEAD WI SCRE N RAIL ® MAT'L 6063-T6 L1- 3.810 1.619rrr 078 --� 1-- S11- SCREEN 3 TRACK FRAME HEAD MATL: 6063-T6 DWG# 4419 1.283 1,619 r--4I--- .078 F S23 - SCREEN 1 TRACK FRAME HEAD MAT'L: 6063-T6 DWG# 4425 L3.810 1.619 i F.078--- S18 - SCREEN 3 TRACK FRAME JAMB MATL: 6063-T6 DWG# 4420 01,283 r -- 1.619 u �_ ,0 S24 - SCREEN 1 TRACK FRAME JAMB MAT'L: 6063-T6 DWG# 4426 1+- 5.505 1 1.235 ,.� 0--7.--8---t�tI--} a17FRA E, 2 TiRAGK WtI51EL�IRAIL ® MATL: 6063 T6 66 - 4 TRACK JAMB MATL: 6063-T6 DWG# 4415 .1L25. 46 F.078 -�►- - S19 - SCREEN 2 TRACK FRAME SILL MATL: 6063-T6 DWG# 4421 78 67 - 3 TRACK JAMB MAT'L: 6063-T6 DWG# 4416 2�.5(4�6'''j� 1.619 F-III►--= .078 S20- SCREEN DWG# 4422 5.505 - --- -1 Fti � 2.625 JL 1��1 .078 ---0 ® MATL:6063-T6 DWG# 4442 a� a- x ii: the D: 1070 MCnNOLOGr oR1Ve �..... .. • .--- - • ••� OPTIONS NOKOILIIS. FL 34275 rae P.O. Box 1529 ALUM. SLIDING GLASS DOOR, IMPACT L,,,;;1s A. Tu,.w. P.E. NOK0611S, FL 34274 V%ihly Better s'"P.''1od11� x» skier a-*wy R., PE 958201 SGD73D NTS 13 a 17 4406-1 E rtecnaracal Le MAIN FRAME EXTRUSION PROFILES 2-TRACK 3-TRACK 4-TRACK 2.,13 SILL �73 2.713 1.3761 � � 1.3.13€ -4.3os 1 HEAD ,s1A J1s U —i a 1s1e � e � 2M �. 1 4, JAMB �1 8. ' r 1,?33 4 1.�55 Z TRACK WITH INTEGRAL SCREEN RAIL 7 JAMB i n n �L . 6.506