Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: (� SCANNED t Permit Number:By ,: - � St. Lucie Coun � / - ty JUN 0 20 Building Permit Application Puc3ho Planning and Development Services Wt. IL1d'die'Count, ;FL Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line Address: _ Legal Description: 1 i o C/Yt�f p Property Tax ID Site Plan Name: Project Name: G� D W&Yt Setbacks Front Back: Lot No. Block No. —� Additional work to (e�e orme un ert is permit—c ec a t app y: Piping n_Sh E1HVAC L_J Gas Tank Gas Pi P g utters Q Windows/Doors Electric 0 Plumbing Sprinklers Generator M_ oof Total Sq. Ft of Construction: �Q® S . Ft. of First Floor: Cost of Construction: $ 00• 00 Utilities: LJ Sewer Septic Building Height: �� OWNER%LESSEE Name Name: Company: , ,o iit C , Address: �o 0 oe/ ' f' Address: City: C4=f State: RL Zip Code: 3 Fax: City: �� State: Phone No. % E-Mail: Zip Coder Fax: Phone No. Fill in fee simple Title Holder on next page ( if different E-Mail: from the Owner listed, above) State or County License: ' ,.,,...,'.,....,., v, a W1 up 0 "U%AJnLfflL;u ,MuuUe yr v ommencemenr is requirefl. no LIEN LA.1N INFO�t1V1/ATIO�I � � �. �� �-�.�'�r�-'� fiSUPPLEl1lIENTALbCONS�RUCTIOIU � y,� �;�t�£ k DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY: _ Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie Counter makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording vour Notice of Commencement. _ Signature of Owner/ Lessee/Agent Signature of STATE OF FLORIDA � I STATE OF FLORIDA COUNTY OF COUNTY OF The forgoing instrument was acknowledg efore me this' of 20by A , (Name ng (Signature ofAotaryPAIi&'5t of Florida ) Personally Known %_, OR Produced Identification Type of Identification Produced Commission No. Revised 07/15/2014 ROY FRAMPTOy iy ISSION k FFJ $glsj6 EXPIRES: January 08, 2019 The forgoing inst ent was acknowledged before me thisAgoYof 20 X by Mlffce 011yJ (Nameofpl�)son acknowledging) (Sign lic- SIAKof Florida) Personally Known _kool OR Produced Identification Type of Identification Produced Commission No. ROY EXPIRES: January08,2019) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE '-INITIALS r� JOSEPH E. SMITH; CLERK OF THE FILE # 4205604 OR BOOK 3885 CIRCUIT COURT SAINT LUCIE COUNTY PAGE 2461, Recorded 06/29/2016 11:59:57 AM 03 qj ( q N©T U OF COMME,NCE�iiENTr Permit No. tC r Taos Folio No State o Honda Cormty of SL. Ludt 'The u fined hereby gWQS nonce that Improvement wilt be nude to certain real property, and In accordance with Oupter713. Florida,Statutes, the MIevAngtnfonn36W 13 Provided in this Ndk a Of COmmenCeMmt, Lesw=}proPer4y San tne�re devallabW- "V) Genenddescr%YWn01knprv#enWd- Owner CornracW%Name: J 7 ContradorAddr�s• ter 5urgty{Napplk�blGawpyoftt+e7raYmentbondis;Amountofbond:$ Name and address Phone number Lender Name: Phone Number. Landers address: persaro w}tNn the State of TWWa deslo aced by Owner upon whom natikes cr other dodaunents rosy be roved as provided bySwdln a .. r ]J�,]�J3) (aU Fiortda stays=V t s_ Name: Phone Number. " ca Addrets: N» Inaddition to himseH or Herseft, Owner designates of to receive a copy of Uenor's Notice as provided In Secton 71113(1) (b). Florida Statuta. Phone number of person or entky designated by owner: •" ` "° Expimtfon date of notice of commencement (the expiration date may not tm bdom the aompWtlon of constr+xtion and VmW payrrentu the contractor, but win be I year from the date of ratordlI g unleas a different date Is spedw) WARNi"aTo:OWNER: AWY PAYMENTgmAm SyTHE 'OWNER AFTER THE E MRATM OFTHE NOTICE OFCOMMENCEWI£NT ARE am IMPROPER PAYMENTS UNDER 0jWtER 713, PART 1, SECTION 713.13, FLORIDA srATurr4 Mo CAN ROWLT IN YOUR PAYlN67WCE FOR IMPROVEMENTSTO YOUR PROPERTY. A NOTICE OF COMMENCEMENT 1.WST BE RECORDED AND POMO ON THEJ08 SME BEFORE THE FI INSPECTION. IFYOU INTEND TO MAIN FINANCING, OONSMT WITHYOUR LENDER OR AN ATTORNEY BEFORE COMMENONG WORK OR IMODRDING Ymi-mancy, or m>V1fiRET1[EtUIew. . Under penalty of PWJ . i declare that i how read the fw.egning noticr of commencement and that the facts stated therm are truth the best of mylmoyAedpi and d lessee, or Owners or Lessee's Auttwrited Wcer/Oirector/partner/Manager GJY (Sitna�tmy'aThl ffice)++ner or -r The foregoing insttumem was vJnowtedged before me O day of 2tl y gyr� r as _ _& A1,4W�for am Person typeofauthor" {eg offxer;irustee) P on haKo emtwastosecuted PetsonaUy lmwn_••,. or produced tdenthr.-I.� gr►3 re of NVMJ Public - State of Florida Pri Type, orstaTnp Commi stoned Na ape of fdentificatfon produced ,FfL�£1.i LtCcpll � min � � JONATNAM fitiAN , g ' F f Mltp -1/00 41 WJ118 iti CaiMn. tspta Jac it), 4 C+DIIIwiitbr +l if i Planning & Development Services aullding & Code Regulation DIVISIon 2300 Virginia Avenue Fort Fierce, FL 34982 772-462-2165 or 772462-2172 Fax: 772-462-6443 R 0 OF jN—S—P E—C-1 —10-N—A-EUI-Q-A�VI I / (0 0-IP - F31TY Re; Permit # �7 g' ,licensed asa(n)Contractot*/Engineer/Architect y *FS468 Building inspector n e type) (Please Print Rme' q ci *general, BulldIngk Re'<denW ar'Rooppg Ccmtraqtor of amyMd/y/dvol -errjfledadder 468F-5- to make such on inspection. On or about I did personally inspect the roof deck nalm (Date) wotk (,job ite,address) aased'upp-tha ay determined the installation was done submitted 'Ift� r^elfn C'Prflnn 611 orthe product approval (whichever is eT Cr License tiS I. T 20 ftre me m1or who has produced ROY -Note,! PU on #iF'Fi88486 Expires Jan. 8, 2019 (Seal) 6117/2016 Florida Building Code Online i � �t 1..,�y.'.„ �•n#-�f^-� _ .. ' ^�.M-g' .`�+L�75 3 �_F _�z-P� Ls..�'s�'-` +r'r:Od vepas T�k-nv-` BCIS Home Log In User Registration .�. Hot Topics .s�fBusinesProduct 1 Approval Ofessibftal USER: Public Use Regulation 4 V;�::'sa-•.:..rS Submit Surcharge I Stabs & Facts j Publications I FBC Staff BCIS Site Map I Links Search 23 Product Approval Menu > Product or Application Search > Application List > Application Detail R_ # FL17022-RS Application Type Code Version Revision 2014 �1! Application Status Approved ST. LITC�' COIT-'ry RUIL nVI'G DIVISION RI';VIEdi LD FOR �' - E Comments 1dEViEIVED BY Q DATE ArchivediD RI�fIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. Product Manufacturer Extreme Metal Fabricators, LLC. Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 tara@extrememeta[fabricators.com Authorized Signature James Buckner jimmy@cbuckinc.net HESE PLAID'S AND ALL PROPOSED WORK Technical Representative Richard McKuhen ARE SUBJECT TO ANY CORRECTIONS Address/Phone/Email SW PFL RE€ LIRED BY FIELD INSPECpTpO�RS THAT Pa2160 lm City, 34990e (772) 872-8034 MAY SE NECESSARY IN ORDER TO rchard@emfab.net ., •E;': COMPLY:WITH ALL APPLID44LE D®DES Quality Assurance Representative Address/Phone/Email CONCEALED FASTENERS OR ATTACHMEi� Category Subcategory Roofing A RE THE RESPONSISIM OF THE Metal Roofing WNTRACTOR OF RECORD Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed James L. Buckner, P.E. @ CBUCK, Inc. the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence PE-31242 Keystone Certifications, Inc. 04/22/2024 Steven M. Urich, PE ' Validation Checklist - Hardcopy Received FL17022 R5 COI CertOfInder).pdf Referenced Standard and Year (of Standard) Standard TAS 125 UL 1897 U L 580 Equivalence of Product Standards Certified By Sections from the Code Year 2003 00• 2006 ILE COP'' https://www.floridabuildina.orator/Or aDD ic..00/ ti. tn__n4.,�1...r................. ,,,, 6/17/2016 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Florida Building Code Online Method 1 Option D 04/20/2016 04/20/2016 04/24/2016 06/08/2016 i - FL # Model, Number or Name Description 117022.1 (1) 5-V Crimp 26 gauge steel, lapped roof panel, mechanically attached to wood deck with exposed screws. Limits of Use ' Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-228 Other: Refer to evaluation report for conditions and limitations of use. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Installation Instructions FL17022 R5 II 1 SVCrimD 26aa WoodDeck EVALREPORT Ddf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL17022 RS AE 1 5VCrimD 26aa WoodDeck EVALREPORTodf Created by Independent Third Party: Yes i 17022.2 (2) 5-V Crimp 0.032" aluminum, lapped roof panel, mechanically attached to wood deck with exposed screws. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-168.5 Other: Refer to evaluation report for conditions and limitations of use. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Installation Instructions FL17022 R5 II 2 SVCrimD 032A1um WoodDeck EVALREPORTpdf Verified By: James L Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL17022 RS AE 2 5VCrimD 032A1um WoodDeck EVALREPORT odf Created by Independent Third Party: Yes 17022.3 (3) 1.5" Mechanical Seam 1.5" rib height 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to wood deck with clips and screws. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-191 Other: Refer to evaluation report for conditions and limitations of use. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Installation Instructions FL17022 R5 II 3 1.5 MechSeam 24aa WoodDeck EVALREPORT Ddf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL17022 R5 AE 3 1.5 MechSeam 24aa WoodDeck EVALREPORT odf Created by Independent Third Party: Yes 17022.4 (4) 1.5" Mechanical Seam 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to wood deck with clips and screws. Limits of Use Installation Instructions Approved for use in HVHZ: No `` Approved for use outside HVHZ: Yes i Impact Resistant: No Design Pressure: +N/A/-191 Other: Refer to evaluation report for conditions and limitations of use. Refer to manufacturer's installation instructions as a supplemental guide for attachment. FL17022 RS II 4 1.5 MechSeam 032A1um WoodDeck EVALREPORT Ddf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL17022 R5 AE 4 1.5 MechSeam 032A1um WoodDeck EVALREPORTDdf Created by Independent Third Party: Yes 17022.5 (5) 1" Nail Strip 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to wood deck with screws. Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-97.25 Other: Refer to evaluation report for conditions and limitations of use. Refer to manufacturer's installation instructions as a supplemental guide for attachment. FL17022 R5 II 5 INailStrio 26aa WoodDeck EVALREPORT Ddf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL17022 R5 AE 5 INailStrio 26aa WoodDeck EVALREPORT odf Created by Independent Third Party: Yes " 1" rib height, 16" wide, 0.032' u to ingOanel L R' Y mechanically attached to woo it scre s. 17022.6 (6) 1" Nail Strip Limits of Use Approved for use in HVHZ: No 1 Approved for use outside HVHZ: Yes Installation Instructions FL17022 R5 II 6 1NailStrio 032A1um WoodDeck EVALREPORT Ddf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 httns:l/www.floridahuildinn.nrn/nr/nr nnn Al . .v, vu„w 4 v VI IIII IC impact Resistant: No ._ ` Design Pressure: +N/, J !.5 Created by Independ� Third Party: Yes Other: Refer to evaluat4> ?port for conditions and limitations of use. Refer to manufacturer's installation Evaluation Reports FL17022 R5 AE 6 11 rip 032A1um WoodDeck EVALREPORTDdf Created by Independent Third Party: Yes j instructions as a supplemental guide for attachment. 17022.7 (7) 1.5" Nail Strip 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to wood deck with screws. i Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL17022 R5 II 7 1.5NailStrio 26ga WoodDeck EVALREPORTpdf Verified .By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-63.5 Evaluation Reports Other: Refer to evaluation report for conditions and limitations of use. Refer to manufacturer's installation FL17022 R5 AE 7 1 SNailStrip 26ga WoodDeck EVALREPORT Ddf Created by Independent Third Party: Yes instructions as a supplemental guide for attachment. 17022.8 (8) EMAX Rib 29 gauge steel, lapped roof panel mechanically attached to wood deck with exposed screws. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R5 II 8 EMAX Rib 29Da WoodDeck EVALREPORT Ddf Approved for use outside HVHZ: Yes I Impact Resistant: No Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Design Pressure: +N/A/-146 Created by Independent Third Party: Yes Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R5 AE 8 EMAX Rib 29oa WoodDeck EVALREPORTodf limitations of use. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions as a supplemental guide for attachment. 1 17022.9 (9) PBR MAX 26 gauge steel, lapped roof panel mechanically attached to wood 1 deck with exposed screws. Limits of Use ' Installation Instructions Approved for use in HVHZ: No FL17022 R5 II 9 PBR Rib 26ga WoodDeck EVALREPORT pdf Approved for use outside HVHZ: Yes Verified By: James L Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-119.5 Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R5 AE 9 PBR Rib 26ga WoodDeck EVALREPORT Ddf limitations of use. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions as a supplemental guide for attachment. �acfc rseat Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S., please dick hers . Product Approval Accepts: t— F " https://www.floridabuilding.orgtpr/pr app dtl.aspx?param=wGEVXQwtDgv2aBQDHDQQe6rMZMkUEoR%2hNvFm7fRfl.ln.Inm�pi 9w,u9nr)ol-%401 %i �r� �f Z CBUCK, Inc. Certificate of Authorization #8064 Evaluation Report ee5®V crimp,"" Metal Roof Assembly Manufacturer: Extreme Metal Fabricators,, LLC. 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 for Florida Product Approval Florida Building Code Sth Edition (2014) Per Rule 61G20-3 Method: 1- D Category: Roofing Sub - Category: Metal Roofing Product: Material: Panel Thickness: Panel Width: Support: Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Youry Demosthenes Report No. 16-123-5V-S6W-ER (Revises 15-217-5V-56W--ER.2) Date: 4 / 18 / 16 Contents: Evaluation Report Pages 1— 7 5-V Crimp Roof Panel Steel 26 gauge 24" Wood Deck Digitally signed by James L. Buckner, P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule 61G15-2 `\'J1111111111 * No 31242 T' STATE OF �rrrr1111►j11` 2016.04.1911:32:32-04'00' CBUCK, Inc. - Palm Beach County, Florida Phone: (561) 491-9927 - Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net 5P 6c56tLj Structural I=nq31n r1nQ Manufacturer: Extreme Metal Fabricators, LLC. Product Name: 5-V Crimp Product Category: Roofing Product Sub -Category Metal Roofing FL #: FL 17022.1 R5 Date: 4 / 18 / 16 Report No.:16-123-5V-S6W-ER Page 2 of 7 CBUCK, Inc Certificate of Authorization #8064 Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System 5-V Crimp Roof Panel, 26 Gauge steel, 24" wide panel mechanically attached to Description: Wood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation Board (Optional) Support. Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32" or greater plywood, • or Wood plank (min. specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure (ASD): Refer to Table A r• . . .- i -�'' YILE C �',rS"�f '4 - FL #: FL 17022.1 R5 Date: 4 / 18 / 16 --z Report No.:16-123-5V-S6W-ER Page 3 of 7 SPSaga w struct ra r=nQinssronQ CBUCK, Inc. Certificate of Authorization #8064 Performance Standards: The product described herein has demonstrated compliance with: • UL580-06 — Test for Uplift Resistance of Roof Assemblies • UL 1897-04 — Uplift test for roof covering systems • TAS 125-03 — Standard Requirements far Metal Roofing Systems Code Compliance: The product described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report This product evaluation is limited to compliance with the structural requirements Scope: of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • This evaluation report for "Optional Statewide Approval" contains technical Conditions of Use: documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". • Option for application outside "Limitations and Conditions of Use" • Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • Deck shall be in compliance with applicable building code. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance progr udd d - ta, ,u d quality assurance entity through Keystone Certificatio , C Or ID# QUA 1824). � U�� FL #: FL 17022.1 R5 Date: 4 / 18 / 16 Report No.: 16-123-5V-S6W-ER Page 4 of 7 SP 1c51f1 j Structural I=ngIn r1nq CBUCK, Inc. Certifticate of Authorization #8064 Components/Materials (by Manufacturer): Roof Panel: Material: Thickness: Panel Widths: Rib Height: Yield Strength: Corrosion Resistance Fastener: FASTENER 1 Type: Size: Corrosion Resistance: Standard: 5-V Crimp Steel 26 Gauge (min.) 24" (max.) Coverage 5/8„ 50 ksi min. In compliance with FBC Section 1507.4.3: • ASTM A792 coated, or • ASTM A653 G90 galvanized steel Used for Attachment Method 1 Hex Washer Head Wood Screw #9 x 1-1/2" (min.) Per FBC Section 1506.6 and 1507.4.4 Per ANSI/ASME 1318.6.1 FASTENER 2 Used for Attachment Method Z 3 & 4 Type: Hex Washer Head Wood Screw Size: #10 x 1-1/2" (min.) Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.1 Components/Materials: Underlayment: (by Others) Material and application shall be in compliance with FBC Section 1507.4.5.1 and 1507.4.5.2, applicable codes and in accordance with manufacturer's recommendations. Insulation (Optional): Type: Rigid Insulation Board Thickness: 3" (max.) Properties: Density: 2.25 pcf (Ibs/ft3) min. Or Compressive Strength: 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1S08. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". Ol L mt C 0 mF Y FL #: FL 17022.1 R5 �.. _ Date: 4 / 18 / 16 Q `= Report No.: 5 - 73-5V-56W-ER Page F=PSa1c3ItLj Structural r= B�In �6n� CBUCK, Inc. Certificate of Authorization #8064 Installation: Installation Method: (Refer to "TABLE A" below and drawings at the end of this evaluation report.) ■ Fastener Spacing: Refer to "TABLE A" Below (attached to the tops of the V's for a total of 3 screws across the width of the panel.) ■ Row Spacing: Refer to "TABLE A" Below (along the length of the panel) ■ Rib Interlock: Lapped ■ Minimum fastener penetration thru bottom of support, 3/16". ■ For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. 61- TABLE "A" ALLOWABLE LOADS X�P) METHOD 1: METHOD 2: METHOD 3: ETHOD 4: Design Pressure (ASD)*: - 86 PSF - 93.5 PSF -101 PSF - 228 PSF Row Spacing: 16" o.c. 16" o.c. 8" o.c. 6" o.c. Fastener Spacing (along rows): 12" o.c. 12" o.c. 12" o.c. 12" o.c. Fastener Size: 1 #9 #10 #10 #10 *Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety 2 to 1. Install the 5-V Crimp roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL 580-06 & UL 1897-04— Uplift Test By Architectural Testing, Inc. - West Palm Beach, FL (FBC Organization #TST ID: 1527) Report No.: D5893.01-450-18, Date: 05 / 02 /14 Report No.: F3366.01-450-18, Date: 12 / 18 /15 2. TAS 125 —Uplift Test By Architectural Testing, Inc. - West Palm Beach, FL (FBC Organization #TST ID: 1527) Report No.: D5893.02-450-18, Date: 07 / 22 /14 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID# Extreme Metal Fabricators, Inc. Licensee # 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineegin (FBC Organization # ANE 1916) FL #: FL 17022.1 R5 Date: 4 / 18 / 16 E:`=—=j) Page 6o7� ` ��� No.:f-5V-S6W-ER g SPSalcsftj Strui=turcsl Engin ing CBUCK, Inc. Certificate of Authorization #8064 i 518 " T Installation Method Extreme Metal Fabricators, I.I.C. 5-V Crimp (26 Gauge steel) Roof Panel attached to Wood Deck Drawings 24" Maximum Net Coverage Panel Profile Nominal 12" o.c. I Nominal 12" o.c. Fastener ' #9 X 1-1/2" Min. or #10 X 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Overlap _ Refer to Table "A" for Spacing Along Panel Length Deck: -15/32" or greater Plywood, or - Wood plank Typical Assembly Profile View (Typical Fastening Pattern Accross Width - Interior I COPY CBUC ' FL #: FL 17022.1 R5 Date: 4 / 18 / 16 Report No.: 16-123-5V-S6W-ER Page 7 of 7 Sg3salc3ltw r=t`ruc=turcql EngIn le-iq3 CBUCK, Inc. Certificate of Authorization O#8064 Installation Method Extreme Metal Fabricators, I.I.C. 5-V Crimp (26 Gauge Steel) Roof Panel attached to Wood Deck Kigia insulation -15/32' or greater Plywood, or Thickness 3' Maximum - Wood plank Typical Roof Assembly Isometric View (Optional) Rigid Insulation Board per Page 4 of this report TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: METHOD 3: METHOD 4: Design Pressure (ASD)*: - 86 PSF - 93.5 PSF -101 PSF - 228 PSF Row Spacing: 16" o.c. 16" o.c. 8" O.C. 6" o.c. Fastener Spacing (across panel width): 12" o.c. 12" O.C. 12" O.C. 2" Fastener Size: #9 410 . 1 * Allowable design pressures) for allowable stress design (ASD) wit a s 1.