Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS_3
C tf M RE: X06-009 - Centex Homes, Model 1702 A o-105- - o4 I A� Site Information: -"'�PY Project Customer: Centex Homes Project Name: Model 1702 'A' Lot/Block: ' Subdivision: Morningsi /!0ode Address: Model 1702 'A' City: Ft. Pierce State: Florida Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2004/TP12002 Design Program:.MiTek 20/20 6.3 Wind Code: N/A Wind Speed: 130 mph Design Method: User defined Roof Load: 55.0 psf Floor Load: 55.0 psf This package includes 50 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G1 5-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# -_ Job ID# Truss Namd Date No. Seal# JJob ID# Truss Namd Date 1 1111180000 X06-009 JAN 10/30/06 118 1111180017 1 X06-009 JCAU 10/30/06 .12 1111180001 IX06-009 IA02 110/30/06 119 1111180018 IX06-009 JCJ3 110/30/06 1 13 1111180002 IX06-009 IA03 110/30/06 120 1111180019 1 X06-009 JCJ3P 110/30/06 14 1111180003 IX06-009 IA03A 110/30/06 121 1111180020IX06-009 JCJ3PA 110/30/06 15 1111180004 IX06-009 IA04 110/30/06 122 1111180021 1X06-009 ICJ3U 110/30/06 1 16 1111180005 IX06-009 IA04A 110/30/06 123 1111180022 1 X06-009 JCJ5 110/30/06 1 17 1111180006 IX06-009 IA05 110/30/06 124' 1111180023 1 X06-009 iCJ5U 110/30/06 1 18 1111180007 1 X06-009 I A06 110/30/06 125 1111180024 1 X06-009 J EG8 110/30/06 1 19 1111180008 JX06-009 IB01 110/30/06 126 1111180025 1X06-009 JEJ5 110/30/06 J 110 1111180009 J X06-009 I B02 110/30/06 127 1111180026 1 X06-009 J EJ7 110/30/06 ill 1111180010IX06-009 IB03 110/30/06 128 1111180027IX06-009 JEJ7A 110/30/06 112 1111180011 I X06-009 I B04 110/30/06 129 1111180028 1 X06-009 J EJ7U 10/30/06 1 113 . 1111180012 IX06-009 IB05 110/30/06 130 1111180029 IX06-009 "IEJ8 110/30/06 J 114 1111180013 I X06-009 I B06 110/30/06 131 1111180030 1 X06-009 J EJ8A j10/30/06 J 115 1111180014 1 X06-009 I B07 110/30/06 132 1111180031 1 X06-009 F01 ott lOi 6 16 1111180015 1 X06-009 IS08 10/30/06 133 1111180032 1 X06-009 F02 ,, ' a 117 1111180016 1 X06-009 - J CJ 1 110/30/06 134 1111180033 1 X06-009 ' F •-' - "i I3 6 The truss drawing(s) referenced above have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by UFP-Ft. Pierce, FL. mD Truss Design Engineer's Name: Tan, Seng-Chaff/n1�lu�Iu�J My license renewal date for the state of Florida is February 28, 2007. NOTE: The seal on these drawings indicate acceptance of 4AY 14 professional engineering responsibility solely for the truss No 67 5f . I. . STATE OF 0 R 10 P•��c`, ��',4"',,i;ALttt,0% Seng-Gftarlrar5-do 2"5 345 Alhambra PL !j VVAftM;'yvbft USE. FL Cert.# 63415 N. Ot r Forty, Des vgl' �e ervitf�f l�rfr?�cf�r � Wes lased only upon parameters shown, and Is for an individual building component. Suite #300 CIO er Appllcabili of desigh parameters and proper incorp�ation of component is r�spgnbll h/ of building design - �1e� Is for lateral support of Individual web members only. Additional temporary bra Irglt nsure stability during cont�8tlo �e&1$7 �Iblllty of the erector. Additional -permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component M iTek° Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property ' 13/n *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in 4- n-sixteenths. Apply plates to both sides of truss 1 • Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. - 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z aterials on inadequately braced trusses. WEBS4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all For 4 x 2 orientation, locate M2_3 �,�, other interested parties. plates 0 f)/in from outside O a = 4. Cut members to bear tightly against each other. I.edge oftruss• OOa 5. Place plates on each face of truss at each joint and c7-e -s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This.symk?ol indicates the regulated byANSI/TPI1. _ requiredt:direction of slots in � connecfor plates, 8 7 6 5 6• Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. * Plate location details available in MiTek 20/20 7• Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design Is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9, Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11 • Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15, Do not cut or alter truss member or plate without prior reaction section Indicates joint approval of a professional engineer. number where bearings occur. 16• Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI.1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek° DSB-89:� , Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® ` ' Connected Wood Trljsses. w - x RE: X06-009 - Centex Homes, Model 1702 A Site Information: Project Customer: Centex Homes Project Name: Model 1702 'A' Lot/Block: /Qe - Subdivision: Morningside Address: Model 1702 'A' City: Ft. Pierce State: Florida No. Seal# Job ID# Truss Namq Date 35 1111180034 1 X06-009 I F04 10/30/06 136 1111180035 1 X06-009 I F05 110/30/06 1 137 1111180036 I X06-009 I F06 110/30/06 1 138 1111180037 I X06-009 J FG1 110/30/06 1 139 1111180038 J X06-009 J FG2 110/30/06 1 140 1111180039 I X06-009 J FG3 110/30/06 141 1111180040 I X06-009 J G E 1 110/30/06 1 142 1111180041 I X06-009 I HJ2 110/30/06 1 143 1111180042 I X06-009 J HJ5 110/30/06 1 144 1111180043IX06-009 IHJ7 110/30/06 J 145 1111180044 IX06-009 JHJ7U 110/30/06 1 146 1111180045 I X06-009 J MV2 110/30/06 1 147 1111180046 I X06-009 J MV3 110/30/06 1 148 1111180047 J X06-009 J MV5 110/30/06 1 149 1111180048 I X06-009 J MV7 110/30/06 1 150 1111.180049 I X06-009 I MV9 110/30/06 1 :�. ``\`��991:IIIILIJJIIII',,I ��� • ��C EN �'• • No SF-• =� - STA E OF p���i' �.4 O R l D ��Iritln lultal�`���� OCT 3 0 2006 �I MAI I UU1 Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 Welk Industries, Inc. 14515 N. Outer Forty, e WARNING - Verify design parameters and READ NOTES ON THIS AN RE RSE SIDE BEFORE USE. rtY� Design valid for use only with MITek connectors. This design Is based only upon l4ai5 ers shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qual!Wcontrol, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe k° Safety Infoimatlon available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. - Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss- vlo and securely seat. * For 4 x 2 orientation, locate Plates 0 -1/16" from outside edge of truss. _ *This symbol relates the required dlreitlon of slots in -connector: plates, * Plate location details ayaiidble in MiTek 20/20 software or upon request:, PLATE SIZE K� The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. 7% BEARING' Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: 'National Design Specification for Metal `Plate Connected Wood Truss Construction. DSB-89: • Design Standard for Bracing. BCSI1: Building,Compollent Safety Information, Guide to Good Practice for Handling, Installing & Bradng of Metal Plate 'Connected Wood Trusses, 0 Er O U o_ 0 Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPII . 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® ' Job Truss Truss Type City ' Ply Centex Homes, Model 1702 A X06-009 A01 COMMON 4 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 - 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:53:59 20(Wage 1' o-0-0 . - 7-2-9 15-0-0 22-9.7 - 30-0-0 7-2-9 7-9-7 7-9.7 7-2-9 ' - Scale = 1:50.1 Y v 5x10 MT18H = ,. 5.00 12 4 5x5 i Sx5 -- 3 5 2 6 1 7 vI : Iv 0 0 _ .3x5 3x5 i14 13 12 11 10 9 8 J 0-0-0 1.5x4 II 3x8 = 1.5x4 II 0-0.0 7-2-9 16-M 22-9-7 29-0-0 30-0.0. r'-" i 1-" 6.2-9 7-9-7 - 7-9.7 6-2-9 1-0-0 Plate Offsets X,Y : 1:0-3-0,0-1-8 , 3:0-2-8,0-3-0 , 5:0-2-8,0-3-0 , :0-3-0,0-1-8, 8:0-3-0,0-0-8 , 14:0-1-11,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.90 Vert(LL) -0.20 9-11 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.64 9-11 >516 180 MT18H 244/190 BCLL 10.0 Rep Stress Incr YES WB 0.15 Horz(TL) 0.08 8 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight 135lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc T1 2 X 4 SYP No.1, T1 2 X 4 SYP No.1 purlins. BOT CHORD 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 8-8-9 oc bracing. , WEBS 2 X 4 SYP No.2 WEBS 1 Row at midpt 3-11, 5-11 REACTIONS (lb/size) 14=1350/0-8-0, 8=1350/0-8-0 Max Harz 14=104(load case 5) Max Uplift 14=-437(load case 5), 8=-437(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-1836/432, 2-3=-2100/577, 3-4=-1640/465, 4-5=1640/465, 5-6=-2100/578, 6-7=1836/432 BOT CHORD 1-1 4=-440/1837,13-14=-544/1837, 12-13=544/1837, 11-12=-544/1837, 10-11=-441/1837, 9-10=-441/1837, 8-9=-441/1837, 7-8=-441/1837 WEBS 3-13=-26/152, 3-11=-525/269, 4=11=97/632, 5-11=525/270, 5-9=-26/152, 2-14=-751/319, 6-8=751/319 NOTES _ 1) Unbalanced roof live loads have been considered-for_this_design— _ 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60._ , 3)_'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are MT20 plates unless otherwise indicated. ■ 5) All plates are 3x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 437 lb uplift at joint 14 and 437 lb uplift at joint 8. LOAD CASE(S) Standard Seng-Chai Tan, FL Lie #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert_.#6634 October 30,2006 A WARNING - Verijg design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 W1 Is for lateral support of Individual web members only. Addiflonal temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component -qualify-control, Safety Infdr-mation available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. MiTek Symbols PLATE LOCATION AND ORIENTATION 13/4 * Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate Plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but lip reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1:' National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building.Compopent Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood TrVsses, EL P Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A OLAXTE Q�20 ■ 500=4 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI I, 7, Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber, 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14, Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless Indicated otherwise. © 2004 MiteP ' K Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 A02 HIP 2 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:00 20MPage 1 o-0-0 6-3-5 13-" 17-" 23-8-11 3G-0 . 6-3-5 6-8-11 4-" 6-8-11 6-3-5 Scale=1:50.t 1 4x6 = 4x6 = 4 5 5.00 12 3 6 ul 2 � 8 1 Io 3x5 3x5 -16 15 14 13 12 11 10 9 3x6 II 1.5x4 11 3x6 = 3x6 = 1.5x4 II US II 1-0-0 GA-M 6.3.5 13-M 17-0-0 23-8.11 28-M 2$O0 i 1 1-0-0 4-11-5 6-8-11 440-0 6-8-11 4-11-5 0-4-0 04-0 1-" Plate Offsets X, 1:0-3-0,0-1-8 , 4:0-3-0,0-2-4 , 5:0-3-0,0-2-4 , 8:0-3-0,0-1-8 , 9:0-3-0,0-0-8 , 16:0-1-11,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.86 Vert(LL) -0.27 13-15 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.67 13-15 >491 180 BCLL 10.0 Rep Stress Incr YES WB 0.33 Horz(TL) 0.08 9 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 137lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 'Except' TOP CHORD Structural wood sheathing directly applied or 2-2-1 oc T2 2 X 4 SYP No.2 pudins. BOT CHORD 2 X 4 SYP SS BOT CHORD Rigid ceiling directly applied or 8-10-12 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 16=1350/0-8-0, 9=1350/0-8-0 Max Horz 16=90(load case 5) Max Uplift 16=-422(load case 5), 9=-422(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1825/425, 2-3=-2075/552, 3-4=-1743/461, 4-5=1557/463, 5-6=-1743/461, 6-7=-2075/553, a 7-8=1825/426 BOT CHORD 1-16=-426/1817, 15-16=-516/1817, 14-15=-516/1817, 13-14=-516/1817, 12-13=291/1557, 11-12=-426/1817, 10-11=-426/1817, 9=10=426/1817, 8-9=-426/1817 WEBS 3-15=66/109, 3-13=-402/241, 4-13=-39/318, 5-12=-39/318, 6-12=-402/242, 6-1 0=-66/1 09, 2-16=-713/280, 7-9=-713/280 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category 11; Exp B; enclosed; .MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6). Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 422 lb uplift at joint 16 and 422 lb uplift at joint 9. Seng-Chaff Tan, FL Lic #46765 LOAD CASE(S) Standard 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 a WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - nottruss designer. Bracing shown Chesterfield, MO 63017 W1 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside a edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 0 :TEE-LQK WWW ■ �0� AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPII I. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown Indicate minimum plating requirements. 11, Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV L r Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 A03 HIP 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:00 20R&Page 1 0-0-0 ' 5-6.4 11.0-0 19-0-0 1 24-512 1 30.0-0 - 5-6-4 5.5-12 B-0-0 5-5.12 5-6-4 Scale=1:50.! .y 10x10 = - 5x7 4 5 5.00 12 1.5x4 1.50 3 6 2 6 1 FUla 0 3x5 3x5 � 14 13 12 11 10 9 3x4 = 3x8 = - 14-0 0-0-1)-0-0 1.A 4,10 11-0-0 19-M 28-6-0 24"CC� I 1-0-0 9-8-0 8-M 9-8-0 0-0-0 0-4-0 Plate Offsets X,Y : 1:0-2-15,0-1-8 , 4:0-4-5,Ed e , 5:0-3-4,0-2-8 , 8:0-2-15,0-1-8 , 9:0-3-0,0-0-0 , 14:0-1-11,0-1-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.71 Vert(LL) -0.23 11-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.87 Vert(TL) -0.57 11-12 >573 180 BCLL 10.0 Rep Stress Incr YES WB 0.09 Horz(TL) 0.08 9 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 137lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS 'Except* TOP CHORD Structural wood sheathing directly applied or 3-4-13 oc T2 2 X 4 SYP No.2 pudins. BOT CHORD 2 X 4 SYP No.1 BOT CHORD Rigid ceiling directly applied or 9-0-15 oc bracing. WEBS 2 X 4 SYP No.2 WEBS 1 Row at midpt 4-11 REACTIONS (lb/size) 14=1350/0-8-0, 9=1350/0-8-0 Max Harz 14=76(load case 6) Max Uplift 14=-404(load case 5), 9=-404(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-17121397, 2-3=2057/556, 3-4=-1902/536, 4-5=-17351538, 5-6=-1902/536, 6-7=-2057/556, 7-8=-1712/398 BOT CHORD 1-14=-434/1772, 13-14=-487/1772, 12-13=-487/1772, 11-12=-387/1735, 10-11=-434/1772, ' 9-10=-434/1772, 8-9=-434/1772 WEBS 3-12=-67/170, 4-12=0/315, 4-11=-144/144, 5-11=1/315, 6-11=-67/171, 2-14=-963/414, 7-9=963/413 NOTES 1) Unbalanced roof live loads have been considered for this design.-------- - 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf-, Category 11; Exp B-, enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3).Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 404 lb uplift at joint 14 and 404 lb uplift at joint 9. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - VerVy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 W1 is for lateral support of Individual web members only. Additional temporary bracing to Insure stabllity during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component M Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. I e Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPII: National Design. Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 IM O U O Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 Ir O U o_ O AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1, 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others, 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 A03A SPECIAL 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:00 200&0_Rage 1 o-" ` 5-0.8 11.0-0 155-3-8 19-" 22-3-0 25-4-6 30-" 1 I _ 5-" 5-11-8 4-3.8 3.6-8 3-3-0 3-1.8 4-7-8 Scale=1:50.: w 5x5 = 46 = 4 5 6 5.00 12 7 1.5x4 3x5 3 8 L4500 2 9 1 19 6x8 = 10Iq7 o 3x5 -20 19 18 17 16 13 12 11 3x6 II 3x6 = 300 = 1.5M 11 3x5 II 3x5 = 3x6 II 0-" 0-" 1-" 8-5-9 15- 0 18-11-8 2230 25-9-10 1 29-" 00-0-0. F 1.0.0 7510 6fr7 3-11-8 3.3-6 3-6-10 3-2-6 1-" Plate Offsets (X,Y):[1:0-3-0,0-1-8],[4:0-2-4,0-2-12],[6:0-3-0,0-2-4],[7:0-1-8,0-1-8],[8:0-2-0,0-1-8j,[10:0-3-0,0-1-8],[11:0-3-0,0-0-12],[12:0-2-0,0-1-8], 14:0-6-4,0-3-0 , 15:0-3-12,0-24, 17:0-2-4,0-1-8 , 20:0-1-11,0-1-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.71 Vert(LL) -0.19 17-19 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.96 Vert(TL) -0.57 17-19 >578 180 BCLL 10.0 Rep Stress Incr YES WB 0.35 Horz(TL) 0.15 11 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 161 lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS *Except* TOP CHORD Structural wood sheathing directly applied or 3-4-9 oc T2 2 X 4 SYP No.2 purlins. BOT CHORD 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. B1 2 X 4 SYP No.1, B6 2 X 4 SYP No.1 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 20=1350/0-8-0, 11=1350/0-8-0 Max Horz 20=76(load case 6) Max Uplift 20=404(load case 5), 11=-405(load case 6) FORCES .,(lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1726/423, 2-3=-2067/552, 3-4=-1916/521, 4-5=-1827/569, 5-6=-2327/667, 6-7=-2554/697, 7-8=-3358/858, 8-9=1813/463, 9-10=-1563/370 BOT CHORD 1-20=441/1783, 19-20=-495/1783, 18-19=384/1681, 17-18=-384/1681, 16-17=17/53, 15-16=0/36, 6-15=150/693, 14-15=-711/3120, 13-14=26/160, 7-14=-76/451, 12-13=51/212, 11-12=364/1559, 10-11=364/1559 WEBS 3-19=-89/171, 4-19=14/226, 4-17=-56/338, 5-..17=7.141217, 15-1.7= 429/1897, 5-15=141/684, 7-15=-900/287, 12-14=-342/1476, 8-14=-361/1575, 8-12=-894/245, 2-20=-952/347, 9-11=-717/258 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. Seng-Chai Tan, FL Lic #46765 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 404 lb uplift at joint 20 345 Alhambra PL and 405 lb uplift at joint 11. West Palm Beach, FL 33405 MiTek Industries, Inc. LOAD CASE(S) Standard FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, ri0 Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 El is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719, Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated, Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. _J� O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside o edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA ICBO SBCCI BEARING Indicates location where bearings �Su (supports) occur. Icons vary but reaction section indicates joint 9F number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 96-31, 95-43, 96-20-1, 96-67, 84-32 4922, 5243, 5363, 3907 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty Ply Centex Homes, Model 1702 A X06.009 A04 HIP' 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:01 20RPage 1 o-0-0 5.8-11 9-0-0 15-0.0 21.0.0 24-3.5 30-0.0 I . 5-8-11 3-3-5 6-0-0 6-0-0 3-3-5 5-8-11 Scale=1:50.1 w 5x8 = 5x8 = 5.00 12 4 5 6 3 7 2 8 1 - 9 FiR- Io 3x5 3x5 i16 15 14 13 12 11 10 3x7 II 3x6 = 3x8 = 3x4 = 3x7 It 3x4 = 3x6 = 1-0-0 0- 0-0 1 Oa 9-0-0 15-M 21-" 2848-0 _I I 1-0.0 7-8-0 6-" 6-" 7-6.0 - 0-4-0 1-0-0 Plate Offsets (X,Y): [1:0-2-15,0-1-8], [3:0-0-0,0-0-0], [4:0-5-4,0-2-4], [5:0-0-0,0-0-0), [6:0-5-4,0-2-4], [7:0-0-0,0-0-0], [9:0-2-15,0-1-8], [10:0-2-11,0-1-12], 16:0-2-11,0-1-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.69 Vert(LL) -0.19 11-13 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.85 Vert(TL) -0.51 11-13 >639 180 BCLL 10.0 Rep Stress Incr YES WB 0.14 Horz(TL) 0.08 10 n/a n/a BCDL 10.0 Code FBC2004ITP12002 , (Matrix) Weight 140 lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS *Except* TOP CHORD Structural wood sheathing directly applied or 3-6-8 oc T2 2 X 4 SYP No.2 purlins. BOT CHORD 2 X 4 SYP No.1 BOT CHORD Rigid ceiling directly applied or 9-4-3 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 16=1350/0-8-0, 10=135010-8-0 Max Horz 16=63(load case 5) Max Uplift 16=-396(load case 3), 10=396(load case 4) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD=. 1-2=1687/433, 2-3=-2027/582, 3=4=1960/590, 4-5=-2268/741, 5-6=-2268/741, 6-7=-1960/590, ' 7-8=2027/582, 8-9=-1687/433 BOT CHORD 1-16=458/1741, 15-16=-460/1741, 14-15=453/1812, 13-14=-453/1812, 12-13=-451/1812, 11-12=-451/1812, 10-11=-458/1741, 9-10=-458/1741 WEBS 3-15=-6/208, 4-15=46/159, 4-13=-202/616, 5-13=415/221, 6-13=-202/616, 6-11=-46/159, 7-11=-6/208, 2-16=-951 /363, 8-1 0=-951/363 NOTES - _--------- .._.--- _— - - 1) Unbalanced roof live loads have been considered for this design. 2),Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. * 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. _ 6)• Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 396 lb uplift at joint 16 and 396 lb uplift at joint 10. Seng-Chaff Tan, FL Lie #46765 345 Alhambra PL LOAD CASE(S) Standard West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, �O Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component O Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 63719. MiTek Symbols PLATE LOCATION AND ORIENTATION 13/q *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 rr O *For 4 x 2 orientation, locate plates 0 -'/16" from outside o edge of truss. R *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building. Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBEREDAETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A MiTek° B AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 v 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® c Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 A04A SPECIAL 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MTek Industries, Inc. Mon Oct 30 11:54:01 a$6 Page 1 0-M 4-7-13 9-0-0 14-0-3 18-11-8 2121-0�1 25.4-8 3 1 F I 4-7-13 4-4-3 5-0-3 4-114 2-" 13-0 3-1-8 4.7-8 Style = 1:51 5x5 = 30 = 1.5x4 II 46 = 5.00 12 4 5 6 7 1.5M II 8 1.5x4 3 9 2 10 1 1 6x8 = 5x8 — 1ril Iq ..,11 6-1 Iv po 3x4 21 20 19 18 17 14 13 12 3x6 11 3x4 = 3x6 = 3x12 = 2x5 II 3x6 11 0-M 0-0-0 1-M 740.6 13-11-12 18-11-8 22-3-0 25-9-10 29-" a0-0-0, I I 1-" 6-M 6.11-6 4-11-12 3.3-8 3-0-10 3-2.6 1-" Plate Offsets (X,Y): [1:0-3-0,0-1-8], [4:0-2-12,0-2-8], [7:0-3-0,0-1-12], [8:0-2-0,0-0-8), [9:0-2-0,0-1-8], [11:0-3-0,0-1-8], [12:0-3-0,0-0-12], [13:0-2-0,0-1-8], 15:0-2-8,0-2-12 , 16:0-2-12,0-2-12 , 18:0-3-4,0-1-8 , 21:0-1-11,0-1-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.68 Vert(LL) -0.19 18-20 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.96 Vert(TL) -0.59 18-20 >554 180 BCLL 10.0 Rep Stress Incr YES WB 0.40 Horz(TL) 0.16 12 n/a n/a BCDL 10.0 Code FBC2004(rP12002 (Matrix) Weight: 161 lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS'ExcepV TOP CHORD Structural wood sheathing directly applied or 3-4-15 oc T2 2 X 4 SYP No.2 purlins. BOT CHORD 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. B1 2 X 4 SYP No.1, B6 2 X 4 SYP No.1 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 21=1350/0-8-0, 12=1350/0-8-0 Max Horz 21=62(load case 5) Max Uplift 21=-396(load case 3), 12=-396(load case 4) FORCES (lb) - Maximum Compression/Maximum Tension '. TOP CHORD 1-2=�1633/430, 2-3=-1982/560, 3-4=71938/567, 4-5=-2240/723, 5-6=-3094/945, 6-7=-3123/944, 7-8=-9411/981, 8-9=-3367/943, 9-10=-1815/503, 10-11=-1566/406 BOT CHORD 1-21=-443/1690, 20-21=-446/1690, 19-20=-465/1793, 18-19=-465/1793, 17-18=-31/131, 16-17=0/77, 6-16=-244/129, 15-16=685/2710, 14-15=-28/159, 8-15=-250/115, 13-14=-50/191, 12-13=-399/1561, 11-12=399/1561 WEBS 3-20=0/210, 4-20-85/103, 4-18=175/640, 5-18=789/295, 1.6_18=-589/2189,-5-16=-250/960, 7-16=-205/674, 7-15=-222/843, 13-15=-383/1500, 9-15=-406/1579, 9-13=-903/269, 2-21=-976/320, 10-12-715/247 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Seng-Chai Tan, FL Lic #46765 5) All plates are 3x5 MT20 unless otherwise indicated. 345 Alhambra PL 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 396 lb uplift at joint 21 West Palm Beach, FL 33405 and 396 lb uplift at joint 12. MiTek Industries, Inc. FL Cert.#6634 LOAD CASES Standard October 30,2006 A WARNING - VeriiN design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. I e Symbols PLATE LOCATION AND ORIENTATION �3/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 -1�16 0 O *For 4 x 2 orientation, locate 04) plates 0 - 1/16" from outside a_ edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected -Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all Cc other Interested parties. O U 4. Cut members to bear tightly against each other. EL 5. Place plates on each face of truss at each joint and OPembed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator, General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements, 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14, Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 A05 HIP 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:02 20OMage 1 tw-0 ` 4-5-1 7-0-0 124-9 174-7 234-0 25-6-15 30-" 4-5-1 2.6-15 54-9 5.2-13 5-4-9 2-6-15 4-5-1 Scale = 1:50.t N 6x10 = 2x5 II 3x4 = 6x10 = 5.00 12 3 15 16 4 17 18 19 5 20 21 6 1.5x4 1.5x4 2 7 1 8 � Io 5x10 14 22 13 23 12 24 25 26 11 27 10 28 9 5x10 6x8 = 5x8 = 6x8 = 0-" 0-" 14-0 7-" 124-9 17-7-7 23-" 29-0-0 300-0, - 1.0-0 6-0-0 5-4-9 5-2-13 5-4-9 6-" 1 0 0 Plate Offsets X, 1:0-5-6,0-2-8 , 3:0-2-12,0-3-12 , 6:0-2-12,0-3-12 , 8:0-5-6,0-2-8, 12:0-2-8,0-2-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.82 Vert(LL) 0.26 11-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.64 Vert(TL) -0.68 11-12 >515 180 BCLL 10.0 Rep Stress Incr NO WB 0.38 Horz(TL) 0.12 8 n/a n/a BCDL 10.0 Code FBC20041TPI2002 (Matrix) Weight: 199lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-4-12 oc T2 2 X 6 SYP SS pudins. BOT CHORD 2 X 8 SYP SS BOT CHORD Rigid ceiling directly applied or 6-2-13 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=2359/0-8-0, 8=2359/0-8-0 Max Horz 1=45(load case 5) Max Uplift 1=-787(load case 5), 8=787(load case 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=5508/1891, 2-3=-5369/1885, 3-15=6768/2450, 15-16=6769/2450, 4-16=-6771/2450, 4-17=-6769/2449, 17-18=-6769/2449, 18-19=-6769/2449, 5-19=-6769/2449, 5-20=-6807/2470, 20-21=-6805/2469, 6-21=-6804/2469, .6-7=-5365/1897, 7-8=-5507/1903 BOT CHORD 1-14=-1706/5012, 14-22=1687/5004, 13-22=-1687/5004, 13-23=-1687/5004, 12-23=-1687/5004, 12-24=2379/6804, 24-25=2379/6804, 25-26=2379/6804, 11-26=-2379/6804, 11-27=1696/4999, 10-27=1696/4999, 10-28=1696/4999, 9-28=1696/4999, 8-9=-1715/5011 WEBS 2-14=-46/111, 3-14=-1121610, 3-12=-759/2050, 4-12=-692/376, 5-12=-104/41, 5-11=-714/375, 6-11=-769/2077, 6-9=-108/600, 7-9=49/111 NOTES 1),Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4). *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x6 MT20 unless otherwise indicated. - 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 787 lb uplift at joint 1 Seng-Chaff Tan, FL Lic #46765 and 787 lb uplift at joint 8. 345 Alhambra PL 7) Han§er(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)158 lb down and West Palm Beach, FL 33405 121 lb up at 7-0-0, 104 lb down and 75 lb up at 9-0-12, 104 lb down and 75 lb up at 11-0-12, 104 lb down and 75 Ib MiTek Industries, Inc. up at 13-0-12, 104 Ib down and 75 lb up at 15-0-12, 1041b down and 75 Ib up at 16-11-4, 104 lb down and 75 lb up FL Cert.#6634 October 30,2006 n S 1`� �°�'8T$ - r { T .3�4 Id� and D ggR�`` id o o yy�vi con ectgg s. i i a d pnly do r e e s o n, an s or in wi ua t�y�nnQ om onent. A (IbtSblllf� d �yZSt ��}•in $ @ * i§i�s &53 4� �ri� f ��Mb/. Brgcing shown 14515 N. Outer Forty, suiterr�oo Chesterfield, MO 63017 IStO lYersEal support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the 8]f4�Y�A$E(19� G1@T611�r1� 1�®Iii Rif 4r IFRRR1 J13 9fIt TFJroy.ff cN%E�ral guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, D B-89 and C511 Building Component M a for t' n vaila le om Truss Plate Institute, 583 D'Onofrio Drive, Madison, wl 53719. i e Symbols PLATE LOCATION AND ORIENTATION 13/q *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat, 0 -1�16 0 M O *For 4 x 2 orientation, locate � plates 0 - 1/16" from outside edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated, BEARING Indicates location where bearings U14 (supports) occur. Icons vary but Lip reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPl1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building, Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Tresses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 0 NONNI TEE-LOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury I . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other, °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design Is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® I Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06-009 A05 HIP 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:02 2006 Page 2 'LOAD CASE(S) Standard -4) Regular: Lumber Increase=1.25, Plate Increase=1.25 lhiform Loads (plf) Vert: 1-3=-70, 3-6=70, 6-8=-70, 1-8=20 Concentrated Loads (lb) Vert: 3=-158(B) 6=1 58(B) 14=-364(B) 9=-364(B)15=-104(B)16=104(13)17=104(B)18=-104(B)19=-104(B) 20=-104(B) 21=-104(13) 22=-44(B)23=-44(B)24=-44(B)25=-44(B)26=44(B)27=-44(B)28=-44(B) A WARNDBG - Verify design parameters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - nottruss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSIMI Quality Criteria, DSB-89 and BCSI1 Building Component O Safety Information available from Truss Plate Institute, 593 D'Onofrio Drive, Madison, WI 53719. M I e Symbols PLATE LOCATION AND ORIENTATION -011 14-13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-'/0 *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the _ required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building..Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Mirtal Plate Connected Wood Trusses. C1 rr O U o_ O R Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 90 0 � TEE-LOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII I. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. O- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design, 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14, Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 A06 HIP 1 1 Job Reference (optional) ,Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946 6.300 s Dec 12005 MTek Industries, Inc. Mon Oct 3011:54:02 20OMage 1 4-5-0 7-" 124-9 17-7-7 23-0-0 25-7-0 30-" 4-5-0 2-7-0 5-0-9 5-2-13 54-9 2-7-0 4-5-0 ,e Scale = 1:50.r 6x10 = 2x5 II 3x4 = 6x10 = 5.00 12 3 14 4 5 15 16 6 1.5x4 1.50 i 2 7 V. 1 8 Io 5x10 13 17 18 12 19 20 11 21 10 22 23 9 5x10 5x8 = 8x8 W6= 0-0.0 0-" 1-0-0I 7-" 124-9 17-7-7 23-" I 29-0-0 i30.0-0i i I � 1.0-0 6.0-0 5-4-9 5.2-13 5-0-9 6-M 1-0.0 Plate Offsets X, 1:0-5-6,0-2-8 , 3:0-2-8,0-3-8 , 6:0-2-0,0-3-8, 8:0-5-6,0-2-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.75 Vert(LL) 0.23 10-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.59 Vert(TL) -0.61 10-12 >579 180 BCLL 10.0 Rep Stress Incr NO WB 0.31 Horz(TL) 0.11 8 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 199lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-6-5 oc T2 2 X 6 SYP SS purlins. BOT CHORD 2 X 8 SYP SS BOT CHORD Rigid ceiling directly applied or 6-8-14 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=2184/0-8-0, 8=2197/0-8-0 Max Harz 1=45(load case 5) Max Uplift 1=-706(load case 4), 8=711(load case 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=5066/1698, 2-3=4915/1688, 3-14=-5939/2079, 4-14=-5942/2080, 4-5=-5940/2079, 5-15=6061/2137, �15-16=-6059/2136, 6-16=-6058/2136, 6-7=4948/1703, 7-8=-5094/1710 BOT CHORD 1-13=-1529/4605, 13-17=-1504/4582, 17-18=-1504/4582, 12-18=-1504/4582, 12-19=2046/6059, 19-20=-2046/6059, 11`20=-2046/6059, 11-21=-2046/6059, 10-21=-2046/6050, 10-22=-1516/4613, 22-23=1516/4613, 9-23=-1516/4613, 8-9=1538/4632 WEBS 2-13=-64/100, 3-13=-110/645, 3-12=549/1592, 4-12=-420/218, 5-12=198/107, 5-10=-543/281, 6-10=-597/1690, 6-9=-104/614, 7-9=-57/101 NOTES 1) Unbalanced roof live loads have been considered for this design. 2)'Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf, Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 706 lb uplift at joint 1 and 711 lb uplift at joint 8. Seng-Chaff Tan, FL Lic #46765 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 158 lb down and 345 Alhambra PL 121 lb up at 7-0-0, 138 lb down and 100 lb up at 8-5-4, 138 lb down and 100 lb up at 19-0-12, and 104 lb down and West Palm Beach, FL 33405 75 lb up at 20-11-4, and 158 lb down and 121 lb up at 23-0-0 on top chord, and 364 lb down and 104 lb up at 7-0-0, MiTek Industries, Inc. 79 lb down at 8-5-4, 61 lb down and 9 lb up at 10-5-4, 56 lb down and 17 lb up at 12-5-4, 24 lb up at 13-9-0, 56 lb FL Cert.#6634 October 30 2006 A N19. a Qgnn t O �� �� � ] f'g connection 14515 N. Outer Forty, Mrt� l Sjpb�ff1f$ 1h X 6 906r6rs. This design Is based only upon parameters shown, and Is for an individual building component. Suite #30 I 8 F�t�1(� �($jrg@ fldbg p�GffiPptg tl6J6�l Ihl6tedf�9ifd09t� s baQit� idesigner. Bracing shown Chesterfield, MO63017 M I Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the �jr��jQ��� �Q� a er n nt bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding I-�artC011@�Y�glltSAt�i rrorage, ANSI/TPII Quality delivery, erection and bracing, consult Criteria, DSB-89 and BCSII Building Component M iTe k° Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside a. edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welt 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but lip reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building.Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and OP embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV 6 Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 A06 HIP 1 1 Job Reference o tional Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:02 2006 Page 2 LOAD CASE(S) Standard �) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=70, 3-6=-70, 6-8=-70, 1-8=-20 Concentrated Loads (lb) Vert: 3=-158(F) 6=158(F) 13=-364(F) 12=-56(F) 9=-364(F)14=-138(F)15=-138(F)16=104(F)17=-39(F)18=46(F) 19=7(F) 20=-56(F) 21=-46(F)22=-39(F)23=-44(F) A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/, *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number Where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building- Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. O U CL O Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and OP embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified, 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® r , Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 B01 HIP 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:03 20% PN% 1 0-0-0 5-6.4 11-0-0 19-0-0 I 24-5.12 F 294W _ 5-64 5.5-12 8-0-0 5.5-12 4.6-4 ,Scale=1:48.1 10x10 = 5x7 = 4 5 5.00 12 3 6 7 2 8 ' Io 0 4x6 US i�- 12 11 10 9 6x8 11 3x6 11 3x4 = 3x6 = 3x8 = 14-0 0-0-0 1 a4,0 it-" 19-0-0 28-M 2440 1-" 9-8-0 8-0-0 9-8-0 04-0 - 04-0 Plate Offsets X,Y : 1:0-3-0,0-1-8 , 4:0-4-5,Edge], 8:0-5-4,Ed e , 12:0-1-11,0-1-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.72 Vert(LL) -0.17 8-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.88 Vert(TL) -0.49 8-9 >683 180 BCLL 10.0 Rep Stress Incr YES WB 0.11 Horz(TL) 0.09 8 n/a n/a BCDL . 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 138 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 3-4-5 oc T1 2 X 4 SYP SS purlins. BOT CHORD 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 9-0-6 oc bracing. B1 2 X 4 SYP No.1 WEBS 1 Row at midpt 4-9 WEBS 2 X 4 SYP No.2 SLIDER Right 2 X 6 SYP SS 2-2-8 REACTIONS (lb/size) 8=1242/0-8-0, 12=136810-8-0 Max Horz 12=76(load case 5) Max Uplift 8=-321(load case 6), 12=-407(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-1744/407, 2-3=-2091/565, 3-4=-1940/548, 4-5=-1815/557, 5-6=-1999/561, 6-7=-2209/610, 7-8=2276/603 BOT CHORD 1-12=-443/1802, 11-12=-492/1802, 10-11=-397/1770, 9-10=-397/1770, 8-9=-484/1977 WEBS 3-11=-62/169, 4-11=0/302, 4-9=109/193, 5-9=-15/364, 6-9=-197/215, 2-12=-968/415 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 321 lb uplift at joint 8 and 407 lb uplift at joint 12. Seng-Chaff Tan, FL Lic #46765 LOAD CASE(S) Standard 345 Alhambra PL West Palm Beach, FL 33405 MTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - VerlJy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, �® Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 O Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCS11 Building Component MiTek° Safety information available from.Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION j314 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 m O *For 4 x 2 orientation, locate v plates 0 - 1/16" from outside o edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building.Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBEREDAMERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1, Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other, a- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1, 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11, Lumber used shall be of the species and size, and in all respects, equal to or better than that specified, 12. Top chords must be sheathed or purlins provided at spacing shown on design, 13, Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type city Ply Centex Homes, Model 1702 A X06.009 B02 SPECIAL 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:03 2006 PM 1 o-ao 5.10-9 11-" 14-5-0 21.0-0 25-6-14 29-0-0 1 I 5-10-9 5.9.15 2-8-8 6-7-0 4-6-14 3-5-2 Scale = 1:49.1 4 5x8 = 5x7 = 5.00 12 5 6 1.5x4 \\ 3 1.5x4 7 8 2 9 ' Io 0 US :14 13 12 11 10 5x8 11 3x6 11 3x4 = 3x6 = 3x8 = 1-0-0 0-" ,1 � 7-10-6 14-5-0 21-0-0 28-8-0 2$-OrO 14 1-" 6fr6 6-0-11 6-7-0 7-&0 0-0-0 ' 0-0-0 Plate Offsets X,Y : 1:0-3-0,0-1-8 , 4:0-2-12,0-2-0 , 5:0-5-4,0-3-0 , 6:0-3-8,0-2-1 , 9:0-5-4,Ed e, 14:0-1-11,0-1-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in floc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.68 Vert(LL) -0.18 12-13 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.98 Vert(TL) -0.54 12-13 >612 180 BCLL 10.0 Rep Stress Incr YES WB 0.33 Horz(TL) 0.09 9 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 143lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 `Except' TOP CHORD Structural wood sheathing directly applied or 3-4-13 oc T1 2 X 4 SYP SS purlins. BOT CHORD 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. B1 2 X 4 SYP No.1 WEBS 2 X 4 SYP No.2 SLIDER Right 2 X 6 SYP SS 1-7-6 REACTIONS (lb/size) 9=124210-8-0, 14=1368/0-8-0 Max Horz 14=-81(load case 6) Max Uplift 9=-381(load case 6), 14=414(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-1814/427, 2-3=-2128/549, 3-4=-1950/540, 4-5=-2568/825, 5-6=-1959/660, 6-7=2135/663, 7-8=-2170/709, 8-9=-2220/705 BOT CHORD 1-1 4=-437/1849,13-14=-500/1849, 12-13=-342/1663, 11-12=546/2315, 10-11=-546/2315, 9-10=-569/1912 WEBS 3-13=191/177, 4-13=-75/238, 4-12=-481/1377, 5-12=-1031/443, 5-1O=413/135, 6-10=-30/413, 7-10=0/84, 2-14=-885/335 NOTES 1)' Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed : Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) -This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 4x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 381 lb uplift at joint 9 Seng-Chai Tan, FL Lic #46765 and.414 lb uplift at joint 14. 345 Alhambra PL West Palm Beach, FL 33405 LOAD CASE(S) Standard MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verifg design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite 41300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 W1 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI M719. Symbols PLATE LOCATION AND ORIENTATION j3/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat, 0 O *For 4 x 2 orientation, locate v plates 0 - 1/16" from outside o edge of truss. R *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building,Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering. System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other, o- 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. S. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber, 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 B03 SPECIAL 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:04 2006 Pig 1 o-o-0 14-0 5.10-2 11-8-8 16-5-0 23-" 25-4-11 28-8-0 29-0r0 I 1 I • 14-0 4-6-2 5-10-6 4-8-8 6-7-0 24-11 3-3-5 04-0 Scale = 1:49.1 4x6 = 4 5.00 12 5x8 = 5x6 zz 3x4 5 6 3 7 3x6 II 8 2 9 ' Io 0 3x5 = 15 14 13 12 11 10 5x7 II 3x8 = 3x6 = 3x8 = 4x6 14-0 0-0-0 5.10-2 11-8-8 16-5-0 23-" 28-8-0 4Or0 -r 1-0-0 4.6-2 5-10-6 4-8-8 6-7-0 5-8-0 04-0 04-0 Plate Offsets X, 1:0-1-6,0-0-2 , 2:0-1-11,0-0-12 , 5:0-5-4,0-2-8 , 9:0-4-8,0-2-1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.85 Vert(LL) 0.33 13-14 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.51 13-14 >647 180 BCLL 10.0 Rep Stress Incr YES WB 0.69 Horz(TL) 0.11 9 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 143lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-10-11 oc T1 2 X 4 SYP No.1 purlins. BOT CHORD 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 4-6-0 oc bracing. B12X4SYP SS WEBS 2 X 4 SYP No.2 SLIDER Right 2 X 6 SYP SS 1-8-13 REACTIONS (lb/size) 9=1242/0-8-0, 15=1368/0-8-0 Max Horz 15=81(load case 5) Max Uplift 9=866(load case 6), 15=-796(load case 4) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1806/1142, 2-3=2056/1303, 3-4=1891/1272, 4-5=1900/1269, 5-6=-2098/1516, 6-7=2226/1569 7-8=-2155/1493, 8-9=2220/1485 BOT CHORD 1 -1 5=-1 123/1796, 14-15=110011796, 13-14=-110011796, 12-13=-1908/2929, 11-12=-190812929, 10-11 =-1 915/2933, 9-1 0=-1 263/1889 WEBS 2-15=-716/377, 3-14=-115190, 3-13=-221/146, 4-13=-794/988, 5-13=-1449/1083, 5-11 =-1 44/199, 5-1 0=-91 9/584, 6-1 O=356/435, 7-1 0=-1 67/234 NOTES 1) -Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed; porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 47-*This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 866 lb uplift at joint 9 Seng-Chaff Tan, FL Lie #46765 and 796 lb uplift at joint 15. 345Alhambra PL West Palm Beach, FL 33405 LOAD CASE(S) Standard MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, - Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 W1 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component O M Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. - I e Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss, *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots, LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building.Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 cr O x U n. O Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 0 TEE' LOKre AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 0- 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1, ' 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type City Ply Centex Homes, Model 1702 A XOB-009 B04 SPECIAL 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946 6.300 s Dec 12005 MiTek Industriwnc. Mon Oct 3011:54:04 2006 �He 1 14-0 638 1t8B 15-8-7 18-6-0 22-1-0 25-" 29-0-0 • 14-0 4-11-8 5-5-0 3-11-15 2.8-10 3-8-0 2-11-0 440-0 Scale =1:50 4x6 = 4 5.00 12 5 46 = 5x7 = 3 6 7 17 8 9 3x6 II 2 10 Io .�' 3x4 3x4 = 16 15 14 13 12 18 11 3x5 II 3x4 = 3x6 = 3x8 = 3x10 = -0-0 0-0-0 0.0.0 1� 6-6-4 15.0.12 =22-1-0 I 254}0 29-0-0 i-- 1.0-0 5-2-4 8-&8 3.44 3-8-0 2-11-0 4-" 04-0 Plate Offsets X,Y : 1:0-1-14,0-0-2 , 2:0-1-11,0-0-4 , 8:0-5-4,0-2-12 , 10:0-3-4,0-0-3 , 12:0-2-8,0-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.86 Vert(LL) -0.18 13-15 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.83 Vert(TL) -0.56 13-15 >441 180 BCLL 10.0 Rep Stress Incr NO WB 0.48 Horz(TL) 0.02 12 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 142lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-4-1 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. W72X6SYP SS SLIDER Right 2 X 4 SYP No.2 2-0-6 REACTIONS (lb/size) 10=-9/0-3-0, 16=915/0-8-0, 12=2006/0-8-0 Max Horz 16=81(load case 6) Max Uplift 10=-208(load case 6), 16=-316(load case 5), 12=-808(load case 6) Max Grav 10=76(load case 8), 16=915(load case 1), 12=2006(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1049/206, 2-3=-1246/321, 3-4=1198/423, 4-5=-787/300, 5-6=-786/231, 6-7=-316/1317, 7-17=-316/1317, 8-17=316/1316, 8-9=0/388, 9-111=01328 BOT CHORD 1-1 6=-213/1062,15-16=294/1062, 14-15=-130/692, 13-14=-130/692, 12-13=-33/250, 12-18=280/0, 11-18=280/0, 10-11=290/0 WEBS 2-16=-592/252, 3-15=284/218, 4-15=-221/549, 4-13=138/152, 5-13=-225/145, 6-13=-131/622, 6-12=-17531472, 7-12=-287/165,-8-12=-1281/646, 8-11=209/255 - NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category ll; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. . 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 208 lb uplift at joint 10, Seng-Chai Tan, FL Lic #46765 316,lb uplift at joint 16 and 808 lb uplift at joint 12. 345 Alhambra PL 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 86 lb down and West Palm Beach, FL 33405 51 lb up at 22-10-15, and 264 lb down and 147 lb up at 25-0-0 on top chord, and 29 lb down and 25 lb up at MiTek Industries, Inc. FL Cert.#6634 22-10-15, and 105 lb down and 82 lb up at 24-10-15 on bottom chord. The design/selection of such connection October 30,2006 SnpaaesaO EeO aC V��g rip �g p Or e maaerE 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Lt` GASX �setalA�deters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown suite #300 IMMIN Chesterfield, MO 63017 1 r suB�fl� S� �S �l lfMde tf?46emporary bracing to insure stability during construction is the responsibility of the erec of r. Ad' Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTek. Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 m O * For 4 x 2 orientation, locate04 v plates 0 - 1/16" from outside o_ edge of truss. OR *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSII : Building,Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII . 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type City I Ply Centex Homes, Model 1702 A X06-009 B04 I SPECIAL 1 1 Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011 LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-4=-70, 4-6=-70, 6-8=-70, 8-10=-70, 1-10=20 Concentrated Loads (lb) Vert: 8=-184(B) 11=-52(B) 17=46(B)18=-20(B) ;-'N A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite H300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - nottruss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding W1 fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component Safety Information available from Truss Plate Institute, 583. D'Onofrio Drive, Madison, WI 53719. MiTek Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property -01 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g, diagonal and securely seat. or X-bracing, is always required, See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack ci-2 cza materials on inadequately braced trusses. o WEBS c3� 4 3. Provide copies of this truss design to the building O designer, erection supervisor, property owner and all For 4 x 2 orientation, locate v 6 Ir �,3 .�'�' � O other interested parties. plates 0 -/1b" from outside a0 �a� U 4. Cut members to bear tightly against each other. edge of truss. I— a 5. Place plates on each face of truss at each joint and c7-e c6-7 cs-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TP11. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MITek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9• Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots, CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. Z�su (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior L�p reaction section indicates joint approval of a professional engineer, number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek® DSB-89: Design Standard for Bracing. BCSI1: Building -Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing. of Metal Plate © 2004 MiteP Connected,Wood Trusses. V\/N� Job Truss Truss Type city Ply Centex Homes, Model 1702 A X06-009 B05 COMMON 2 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:05 200@aage 1 o-0-0 5-10-9 1148-8 17-6-8 22-5-0 5.10-9 5-9-16 5.10-0 4-10-8 Scale=1:40.: 5x5 = 4 5.00 12 3 5 ul 2 7 Io 0 4x6 3x5 � 11 10 9 8 5x8 II " 3x6 I I 3x4 = 4x6 = 3z4 = 0-" 0-" 1-" 1 4 7-10-0 15-6-10 2250 1-" 0-" 6-6-6 M-4 6-10-6 Plate Offsets X, 1:0-3-0,0-1-8 , 4:0-2-8,Ed e , :0-5-4,Ed e , 11:0-1-11,0-1-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.78 Vert(LL) -0.20 8-10 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.86 Vert(TL) -0.62 8-10 >410 180 BCLL 10.0 Rep Stress Incr NO WB 0.16 Horc(TL) 0.07 7 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 103lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS 'Except* TOP CHORD Structural wood sheathing directly applied or 3-4-5 oc T2 2 X 4 SYP No.2 pudins. BOT CHORD 2 X 4 SYP SS 'Except* BOT CHORD Rigid ceiling directly applied or 8-6-10 oc bracing. B2 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.2 SLIDER Right 2 X 6 SYP SS 2-7-7 REACTIONS (Ib/size) 7=1417/0-8-0, 11=1609/0-8-0 Max Horz 11=81(load case 5) Max Uplift 7=-394(load case 6), 11=-498(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=19481473, 2-3=2255/621, 3-4=-2083/589, 4-5=2243/646, 5-6=2380/686, 6-7=-2457/668 BOT CHORD 1 -11 =-485/1965, 10-11=-566/1965, 9-10=-348/1527, 8-9=348/1527, 7-8=-550/2144 WEBS 3-1 0=1 64/169, 4-1 0=-1 76/641, 4-8=-245/844, 5-8=-220/190, 2-11=-868/339 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3)-*This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 394 lb uplift at joint 7 and 498 lb uplift at joint 11. LOAD CASE(S) Standard " 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Seng-Chai Tan, FL Lic #46765 Uniform Loads (pig 345 Alhambra PL Vert: 1-4=-70, 4-7=-70, 1-7=-65 West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 !A WARNING - Verifg design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 W1 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component MiTek. Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION -011 14-13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat, 0 O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside h- edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 .3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT The first dimension is the width NUMBERS/LETTERS. 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building.Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected -Wood Trusses. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a- 5. Place plates on each face of truss at each joint and OP embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements, 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 B06 HIP 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:05 200�.&ge 1 0-" 5-0-10 it-" 12-5-0 18A-6 23-5-0 ' 5-0-10 5-11.6 1-5-0 6-11-6 5-0-10 Scale =1:38 - 5x5 = 5x5 = 4 5 5.00 12 1.5x4 1.Sx4 i 3 8 2 7 1 8 Io 12 11 10 3x6 II 3x6 = 3f"l 0-" , 8.5.10 14-11-5 22-&0 , 23-5-0 , 1-0-0 7-5-11 6-5.11 7-5-11 1.0-0 Plate Offsets X,Y : 1:0-3-0,0-1-8 , 4:0-2-4,0-2-8 , 5:0-2-4,0-2-8 , 8:0-3-0,0-1-8 , 9:0-3-0,0-0-8 , 13:0-1-11,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.91 Vert(LL) -0.15 10-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.88 Vert(TL) -0.40 10-12 >624 180 BCLL 10.0 Rep Stress Incr NO WB 0.07 Horz(TL) 0.05 9 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 102lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 'Except* TOP CHORD Structural wood sheathing directly applied or 3-7-9 oc T2 2 X 6 SYP SS purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 9-7-10 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 13=1054/0-8-0, 9=1054/0-8-0 Max Horz 13=76(load case 6) Max Uplift 13=348(load case 5), 9=-348(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-1249/308, 2-3=1504/440, 3-4=-1309/342, 4-5=-1082/350, 5-6=1309/342, 6-7=1504/440, 7-8=1249/308 BOT CHORD 1-1 3=-327/1288,12-13=-403/1288, 11-12=220/1082, 10-11=-220/1082, 9-10=-328/1288, 8-9=-328/1288 WEBS 3-12=-217/191, 4-12=-36/279, 5-10=-36/279, 6-1O=217/192, 2-13=-736/304, 7-9=736/303 NOTES 1) Unbalanced roof live loads have been considered for this design.-. -. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3)'Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ` 5) All plates are 3x4 MT20 unless otherwise indicated. . 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 348 lb uplift at joint 13 and 348 lb uplift at joint 9. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lie #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30 2006 A WARNING - Verijy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCS1I Building Component MiTek safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. O * For 4 x 2 orientation, locate plates 0 -/ie" from outside edge of truss. o O- *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standal:d for Bracing. BCSI1: Building.Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected.Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 0 TEE=L04 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design Is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15, Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 B07 HIP 1 1 Job Reference (optional) ,Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MTek Industries, Inc. Mon Oct 3011:54:05 2004(�.&ge 1 o-0-0 5-8-11 9-0-0 14-5-0 17-8-5 23-5-0 i 1 5-8-11 335 5-5-0 3-3-5 5-8-11 Scale = 1:38 5x7 = 4x6 = 4 5 5.00 12 1.5x4 Z�- 1.5x4 3 6 2 7 8 1 Io 12 11 10 ' 3x6 11 3x6 = 3x8 = 3x6 11 0-0-0 0-" 23-5-0 1-" 10:F 9-0-0 14-5-0 22-1-0 2j-SFO i 1 1-" 0-0-0 7-8-0 5.5-0 7-8-0 0-4-0 1-" Plate Offsets X,Y : 4:0-5-4,0-2-12 , 9:0-3-0,0-0-12 , 13:0-1-11,0-0-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.92 Vert(LL) -0.14 10-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.80 Vert(TL) -0.33 10-12 >746 180 BCLL 10.0 Rep Stress Incr YES WB 0.07 Horz(TL) 0.05 9 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 104lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 13=1054/0-8-0, 9=1054/0-8-0 Max Horz 13=62(load case 5) Max Uplift 13=331(load case 5), 9=-331(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1213/272, 2-3=1463/390, 3-4=-1315/376, 4-5=-1214/375, 5-6=1315/376, 6-7=-1463/390, 7-8=-1213/272 BOT CHORD 1-13=290/1246, 12-13=322/1246, 11-12=252/1213, 10-11=252/1213, 9-10=-290/1245, 8-9=290/1245 WEBS 3-12=-62/121, 4-12=-15/217, 4-1O=95/95, 5-10=10/217, 6-10=-62/122, 2-13=-726/326, 7-9=-726/325 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category ll; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to -prevent water ponding. - — - - - - - - 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5), All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 331 lb uplift at joint 13 and 331 lb uplift at joint 9. LOAD CASES) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verijg design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 W1 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. 1 ITe Symbols PLATE LOCATION AND ORIENTATION 1314 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. -1/16" 0 O * For 4 x 2 orientation, locate 7- plates 0 - 1/16" from outside edge of truss. o R *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but lip reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. C- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1, 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. I 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better tharj that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others, 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 B08 HIP 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:06 29" Pagel o-0-0 4-7-4 7-" 11-8-6 16-5-0 i 16-9-12 23-5-0 . r 4-7.4 2-4-12 4-" 4-8-8 2-4-12 4-7-4 Scale =1:39 1.5x4 II 5.00 12 4 13 14 5 15 16 6 1.5x4 �� 1.5x4 i 3 7 2 6 9 1 I Io 3x4 = 5x10 3x4 = 12 17 18 11 19 20 10 5x10 3x4 = 3x4 = 0-0-0 0-M 1-" 7-" 11-8-6 16-5-0 22-5-0 I2 i I 1-M 6-" 4-8-8 448-6 6-0-0 1-" Plate Offsets X, 1:0-3-2,0-2-8 , 4:0-5-4,0-24, 6:0-5-4,0-2-4 , 9:0-3-2,0-2-5 , 11:0-4-0,0-3-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.48 Vert(LL) 0.15 11 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.76 Vert(TL) -0.42 10-11 >655 180 BCLL 10.0 Rep Stress Incr NO WB 0.16 Hofz(TL) 0.15 9 n/a n/a BCDL 10.0 Code FBC20041TPI2002 (Matrix) Weight: 117lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-9-1 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-8-13 oc bracing. SLIDER Left 2 X 6 SYP SS 2-0-11, Right 2 X 6 SYP SS 2-0-11 REACTIONS (lb/size) 1 =1 841/0-8-0, 9=1841/0-8-0 Max Horz 1= 49(load case 6) Max Uplift 1=-624(load case 5), 9=-624(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=3943/1341, 2-3=-3841/1352, 3-4=3835/1330, 4-13=-4219/1511, 13714=4219/1611, 5-14=-4219/1511, 5-15=-4219/1511, 15-'16=4219/1511, 6-16=4219/151'1 �,6-7=3835/1330, 7-8-3841/1353, 8-9=-3943/1342 BOT CHORD 1-12=1224/3532, 12-17=-1180/3565, 17-18=-1180/3565, 11-18=-1180/3565, 11-19=-1156/3565, 19-20=1156/3565, 10-20=-115613565, 9-10=-1176/3532 WEBS 3-12=-18/160, 4-12=-103/557, 4-11=-306/849, 5-11=618/346, 6-11=306/849, 6-10=-103/557, 7-10=-18/160 NOTES 1). Unbalanced roof live loads have been considered for this design. 2)`Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. " 3) Provide adequate drainage to prevent water ponding. 4) *Thig truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 5x8 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 624 lb uplift at joint 1 and 624 lb uplift at joint 9. Seng-Chaff Tan, FL Lic #46765 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 158 lb down and 345 Alhambra PL 121 lb up at 7-0-0, 104 lb down and 75 lb up at 9-0-12, 104 lb down and 75 lb up at 11-0-12, 104 lb down and 75 lb West Palm Beach, FL 33405 up at 12-4-4, and 104 lb down and 75 lb up at 14-4-4, and 158 lb down and 121 lb up at 16-5-0 on top chord, and MiTek Industries, Inc. 364 lb down and 104 lb up at 7-0-0, 64 lb down at 9-0-12, 64 lb down at 11-0-12, 64 Ib down at 12-4-4, and 64 lb FL Cert.#6634 October 30,2006 I IS eS Onsi I I o e S y��1� to a d O I, �AAT' REVS$ HI E_ $ QRE US � N4t1 TLW� � r�ei l� 9 4S tR4sg�� p� ��irrl 5 l ti' R 'isir (X%i&al building component. Suite #300 14515 N. Outer Forty,](e' Applicability of design parameters and proper Incorporation of component is responsibility of building designer -not truss designer. Bracing shown Chesterfield, MO 63017 L®�4 ($prBtbadfyWcil web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component MPiTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/,a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside o edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED.BY END JOINT The first dimension is the width NUMBERS/LETTERS. 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek@ DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties, O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown Indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06.009 B08 HIP 1 1 Job Reference o tional Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:06 2006 Page 2 LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 ' Uniform Loads (plf) Vert: 1-4=-70, 4-6=-70, 6-9=-70, 1-9=-20 Concentrated Loads (lb) Vert: 4=-158(13) 6=-158(13) 12=-364(B)10=-364(B)13=-104(13) 14=104(13) 15=-104(13)16=-104(13) 17=-44(B)18=-44(B) 19=-44(B) 20=-44(B) A WARNING - Versify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe k° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/14 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate M plates 0 - 1/16" from outside o edge of truss. P *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output, Use T, I or Eliminator bracing if indicated. BEARING Indicates location where. bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSI1: Building .Component Safety Information, Guide to Good Practice for Handling, .Installing & Bracing of Mdtal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber, 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Cdy Ply Centex Homes, Model 1702 A X06.009 CJ1 MONO TRUSS 9 0-411 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:06 20D6 Page 1 2 0-0-0 1.0-0 1.0.0 5.00 12 Scale = 1:5.1. MTS16 1 3x4 = 3 OA-10 0-H 1-" 1-" Plate Offsets X, 1:0-0-0,0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) -0.00 1 n/r 180 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) -0.00 1 Ink 90 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 3lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc BOT CHORD 2 X 4 SYP No.2 pudins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 3=10/Mechanical, 2=79/Mechanical Max Horz 3=-98(load case 1), 2=98(load case 1) Max Uplift 3=-14(load case 3), 2=50(load case 5) Max Grav 3=20(load case 2), 2=79(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=80/119 BOT CHORD 1-3=98/82 R, NOTES 1) Wind: ASCE 7-02;130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf, Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate•capable of withstanding 14 lb uplift at joint 3 and 50 lb uplift at joint 2. 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARN/NG - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 W1 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property T'/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. 1. Additional stability bracing for truss system, e.g. diagonal Apply plates to both sides of truss or X-bracing, is always required. See BCSI1. and securely seat. 2 3 0-' TOP CHORDS 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. c1-2 c2-3 WEBS °3b 4 3. Provide copies of this truss design to the building O designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate m N 1 5 other interested parties. plates 0 -/ie" from outside O 4. Cut members to bear tightly against each other. edge of truss. h o 5. Place plates on each face of truss at each joint and c7-e csa ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1, _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERI D CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINI FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY ENC JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 6-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design, if indicated. ICBO 4922, 5243, 5363, 390 13. Bottom chords require lateral bracing at 10 ft. spacing, 5 SBCCI 9667, 9730, 9604B, 95, 1, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings U14 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. 9F number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. BCSI1: Building .Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate �' © 2004 Mitek® , Connected Wood Trusses. V\/° Job Truss Truss Type city Ply Centex Homes, Model 1702 A X06.009 CJ1U MONO TRUSS B 0-411 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:06 2006 Page 1 2 0-0-0 1-0-0 1-ao 5.00 F12 Scale = 1:5.! MTS16 1 U4 = 3 0-4-10 0-0-0 r 1.M LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) -0.00 1 n/r 180 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) -0.00 1 n/r 90 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 3lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 3=10/Mechanical, 2=79/Mechanical Max Horz 3=99(load case 1), 2=99(load case 1) Max Uplift 3=-14(load case 3), 2=-50(load case 5) Max Grav 3=20(load case 2), 2=79(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-80/120 BOT CHORD 1-3=99/82 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3 and 50 lb uplift at joint 2. _ 5) Non Standard bearing condition: Review requiFed. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verijy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component MiTek- Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. O *For 4 x 2 orientation, locate v plates 0 -'/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but I_iF reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National, Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Tomponent Safety Information, Guide to'Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A J �� TEE-LOK, AGeneral Safety Notes Failure to Follow Could Cause Property Damage or .Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4, Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber.' 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11, Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06-009 CJ3 MONO TRUSS 4 1 Job Referen tional Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:06 2006 Page 1 0-0-0 3-M 3.0.0 Scale =1:9.1 5.00 12 2 1 U4 = 404 i 1-0-0 14-03X6 3-" 1-0-0 0-4-0 1-6-0 Plate Offsets X, 5:0-1-11,0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) 0.00 5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) 0.00 4-5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 10lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=28/Mechanical, 4=6/Mechanical, 5=242/0-8-0 Max Horz 5=56(load case 5) Max Uplift 3=-22(load case 5), 4=-6(load case 1), 5=-126(load case 5) Max Grav 3=28(load case 1), 4=12(load case 5), 5=242(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=55/33, 2-3=32/6 BOT CHORD 1-5=0/56, 4-5=0/0 WEBS 2-5=-165/95 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) "This truss has been designed for a 10:0 psf_bottom chord live load nonconcurrent with any other -live loads. 3) Refer to girder(s) for truss to truss connections. 4)'Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 22 lb uplift at joint 3, 6 lb uplift at joint 4 and 126 lb uplift at joint 5. ' LOAD CASE(S) Standard Seng-Chaff Tan, FL Lie #46765 345 Alhambra PL West Palm beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, r_�0 Design valld for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicablllty of design parameters and proper Incorporation of component Is responsibility of building designer- nottruss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responslblllty of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION Ali 14-13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss, *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSII : . Building.Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected,Wood Trusses. 0 CC O U o_ O Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS I BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95A3, 96-20-1, 96-67, 84-32 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII . 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements, 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06-009 CJ3P MONO TRUSS 1 1 Job Referen tional Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:07 20M Page 1 o-M 3-0-0 3-0-0 Scale = 1:9.1 • 5.00 12 2 1 3x4 = NA 5 4 132i`1D 3.0-0 I 1-0-0 0-1-8 1-10-8 Plate Offsets X,Y : 1:0-0-0,0-0-0 , 5:0-1-11,0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.07 Vert(LL) 0.00 5 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.05 Vert(TL) 0.00 5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.01 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 10lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc BOT CHORD 2 X 4 SYP No.2 pudins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=44/Mechanical, 4=6/Mechanical, 5=214/0-3-0 Max Horz 5=56(load case 5) Max Uplift 3=34(load case 5), 4=-29(load case 4), 5=-136(load case 5) Max Grav 3=44(load case 1), 4=23(load case 2), 5=214(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=55/29, 2-3=-32/12 BOT CHORD 1-5=0/56, 4-5=0/0 WEBS 2-5=-154/83 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf, Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom_ c_h_o_rd live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections— - 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 34 lb uplift at joint 3, 29 db uplift at joint 4 and 136 lb uplift at joint 5. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL - West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 ® WARNING - Verify design parameters and READ NOTES oN TBIs AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION -011 14-13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 M O * For 4 x 2 orientation, locate v plates 0 -1/16" from outside edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but V�w reaction section indicates joint L_t�_ number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building.Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected.Wood Tuisses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII . 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11, Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06.009 CJ3PA MONO TRUSS 1 1 Wiphl Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:07 2006 Page 1 0-0-0 2-M 3 2-0-0 5.00 12 Scale =1:9.1 2 1 3x4 4 va�m r3x5 11 2-" 2-M Plate Offsets X,Y : 1:0-1-8,0-0-3 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.06 Vert(LL) -0.00 1 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.04 Vert(TL) -0.00 1-4 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horc(TL) 0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 8lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. SLIDER Right 2 X 4 SYP No.2 1-1-3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=89/0-3-0, 4=20/Mechanical, 3=70/Mechanical Max Horz 1=57(load case 5) Max Uplift 1=-47(load case 5), 4=-29(load case 3), 3=-55(load case 5) Max Grav 1=89(load case 1), 4=40(load case 2), 3=70(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-39/0, 2-3=-25/20 BOT CHORD 1-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections: __---------_ - - 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 1, 29 ,lb uplift at joint 4 and 55 lb uplift at joint 3. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - VerrJy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, s•s•O Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an individual bullding component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component O MiTek. Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated, Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 X O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT The first dimension is the width NUMBERS/LETTERS. 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek@ DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, MEMO Installing & Bracing of Metal Plate Connected Mood Trusses. " AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury l . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements, 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. r I © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 CJ3U MONO TRUSS 8 1 Job Referen tional Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:07 2006 Page 1, 3-0-0 3-M Scale =1:9.1 5.00 12 2 1 U4 = 4 132i[D I 1-M l 1-" „ 3-0-0 - 1.0-0 0-" 1-8-0 Plate Offsets X, 5:0-1-11,0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) 0.00 5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) 0.00 4-5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.02 HOrz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 10lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc BOT CHORD 2 X 4 SYP No.2 pudins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=28/Mechanical, 4=-6/Mechanical, 5=24210-8-0 Max Horz 5=56(load case 5) Max Uplift 3=22(load case 5), 4=-6(load case 1), 5=126(load case 5) Max Grav 3=28(load case 1), 4=12(load case 5), 5=242(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=55/33, 2-3=32/6 -$OT CHORD 1-5=0/56, 4-5=0/0 WEBS 2-5=-165/95 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf,- BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord -live load_nonconcurrent with any other live loads. --- 3) Refer to girder(s) for truss to truss connections. 4).Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 22 lb uplift at joint 3, 6 lb 'uplift at joint 4 and 126 lb uplift at joint 5. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verily design parameters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, �O Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite *300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - nottruss designer. Bracing shown Chesterfield, MO 63017 O Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. MiTek Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate � plates 0 - 1/16" from outside o edge of truss. R *This symbol indicates the, required direction of slots in connector plates. * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where.bearings N14 (supports) occur. Icons vary but E��F reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building .Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected,Woosd Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A we K AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. (- 5. Place plates on each face of truss at each joint and OP embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6, Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8, Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10, Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 CJ5 MONO TRUSS 4 1 Job Reference o tional Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Ind.—Mn Oct 30 11:54:07 20016 Page 1 0-0-0 5-0-0 5-0-0 3 Scale =1:14 1 5.00 12 2 1, 3x4 = - 4 2mm 04W 3x6 11 I 1-M F1-0-0 { 5-04) i 1-" 04-0 3-8-0 Plate Offsets X, 5:0-1-11,0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.15 Vert(LL) -0.01 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.09 Vert(TL) -0.01 4-5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horc(TL) -0.01 3 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 16lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 cc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS (lb/size) 3=106/Mechanical, 4=34/Mechanical, 5=304/0-8-0 Max Horz 5=94(load case 5) Max Uplift 3=-70(load case 5), 5=131(load case 5) Max Grav 3=106(load case 1), 4=62(load case 2), 5=304(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=101/40, 2-3=56/31 BOT"CHORD 1-5=0/94, 4-5=0/0 WEBS 2-5=-246/149 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom -chord- live load noncoricurrent with any other live, -loads. 3) Refer to girder(s) for truss to truss connections. 4),Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 3 and 131 lb uplift at joint 5. ' LOAD CASE(S) Standard Seng-Chaff Tan, FL Lie #46765 - 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30 2006 A WARNING - Verft design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 W1 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. MiTek. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-1/0 *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 0 CC O 0 o- O H Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT The first dimension is the width NUMBERS/LETTERS. 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A BEARING Indicates location where bearings (supports) occur. Icons vary but Lip reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building ,Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. R AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, properly owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or puriins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 CJISU MONO TRUSS 8 1 Job Reference o tional Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Ind.-Mn Oct 3011:54:07 2006 Page 1 - . 0-0.0 5-0-0 Scale=1:14.1 5.00 12 2 - 1 3x4 = 4 �1D 0-" 3x6 II 1.0-0 , 14-0 5-" 1-0-0 0-4-0 3-6-0 Plate Offsets X, 5:0-1-11,0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.15 Vert(LL) -0.01 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.09 Vert(TL) -0.01 4-5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) -0.01 3 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 16lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=106/Mechanical, 4=34/Mechanical, 5=304/0-8-0 Max Horz 5=94(load case 5) Max Uplift 3= 70(load case 5), 5=131(load case 5) Max Grav 3=106(load case 1), 4=62(load case 2), 5=304(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=401/40, 2-3=-56/31 BOT CHORD 1-5=-0/94, 4-5=0/0 S, WEBS 2-5=246/149 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a -10.0 psf bottom chord live-load_-nonc©nsu_rr_ent-_with any other live loads.- 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 3 and 131 lb uplift at joint 5. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, r_�0 Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- nottruss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, cal 53719. MiTek Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 Cr O * For 4 x 2 orientation, locate v 001) plates 0 - 1/16" from outside o edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood! Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 c TEE Wk ®General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses, 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o- 5. Place plates on each face of truss at each joint and 0 embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others, 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16, Install and load vertically unless indicated otherwise. ' I © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 EGB SPECIAL 2 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Ocf@044 t:54:07 2006 Page 1 0-0-0 2-10-8 3-10-8 84-0 . i 2-10-8 1-M 4-1-8 5 1 Scale = 1;19., 4x6 = 46 = 5.00 12 1.5x4 II 3 4 2 . n 1 8 7 6 20f0.00 0-M1.5x4 11 24-0 2-10-8 3-10-8 8-" _ 1 1 1 2-M 0-10-8 1-0-0 4-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Lld PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.30 Vert(LL) -0.02 7-8 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.20 Vert(TL) -0.06 7-8 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.03 Horz(TL) -0.00 5 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 35lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 2 X 4 SYP No.2 puriins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 5=142/Mechanical, 6=66/Mechanical, 9=506/0-8-0 Max Horz 9=131(load case 5) Max Uplift 5=-90(load case 5), 6=-6(load case 4), 9=-236(load case 5) Max Grav 5=142(load case 1), 6=101(load case 2), 9=506(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=142/110, 2-3=83/0, 3-4=-92/39, 4-5=-46/44 BOT CHORD 1-9=-54/146, 8-9=-54/24, 7-8=-59/68, 6-7=0/0 WEBS n 3-8=0/154, 4-8=-189/81, 4-7=-72/62, 2-9=-356/133 =� NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load-nonconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6' Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 90 lb uplift at joint 5, 6 lb uplift at joint 6 and 236 lb uplift at joint 9. LOAD+CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 a 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES oN THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component k Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, W153719. M ITe Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but lip reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected,Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e,g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties, O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. Qosa TEE=LO;K� 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 EJ5 MONO TRUSS 2 1 Job Reference o 6 Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946 6.300 s Dec 12005 MiTek Industries, Inc. t 30 11:54:07 2006 Page 1 o-M • 3 5-0-0 Scale=1:13.1 6.00 12 2 1 • 3x4 = 54W 1.0-0 0-1-8 3-10-6 Plate Offsets X, 5:0-1-11,0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.18 Vert(LL) 0.02 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.11 Vert(TL) -0.02 4-5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) -0.01 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 16lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural woad sheathing directly applied or 5-0-0 oc BOT CHORD 2 X 4 SYP No.2 pudins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=116/Mechanical, 4=40/Mechanical, 5=288/0-3-0 Max Horz 5=94(load case 5) Max Uplift 3=81(load case 5), 4=-59(load case 4), 5=184(load case 5) Max Grav 3=116(load case 1), 4=69(load case 2), 5=288(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=96/40, 2-3=58/34 BOT CHORD 1=5=0/94, 45=0/0 WEBS 2-5=-248/127 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf-bottomchord live load non_c_one_u_rre_n_t_-with-any-other live loads.- 3) Refer to girder(s) for truss to truss connections. 4). Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 lb uplift at joint 3, 59 lb uplift at joint 4 and 184 lb uplift at joint 5. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lie #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 e WARNING - VeryJ, design parameters and BEAD NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, iiiiiiw � O Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTek. Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building r-omponent Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 0 TEE-LOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties, O U 4. Cut members to bear tightly against each other. a- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown Indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 EJ7 MONO TRUSS 6 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. W@Ifftt 30 11:54:0820016 Page 1 0-0-0 7-" 7.0.0 3 Scale=1:19.- 5.00 12 2 1 3x4 -_ 4 2010-00 0-M 3x6 II 1-" ,14-07.0-0 + 1-0-0 0.4-0 5-8-0 Plate Offsets X, 5:0-1-11,0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.39 Vert(LL) -0.04 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.26 Vert(TL) -0.11 4-5 >604 180 BCLL 10.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.04 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 22lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=174/Mechanical, 4=64/Mechanical, 5=386/0-8-0 Max Hors 5=131(load case 5) Max Uplift 3=-110(load case 5), 5=-149(load case 5) Max Grav 3=174(load case 1), 4=104(load case 2), 5=386(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=154/56, 2-3=-84/52 BOT CHORD 1-5=-0(131, 4-5=0/0 '> WEBS 2-5=-358/228 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) `This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any- otheJiv_e loads. 3) Refer to girders) for truss to truss connections. - — - 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 3 and 149 lb uplift at joint 5. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verijy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Ole is for lateral support of individual web members only. Additional temporary bracing to Insure stabllity during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Me k Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. ITe Symbols PLATE LOCATION AND ORIENTATION -01 14-13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 Cr O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside CL edge of truss. R *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but reaction section indicates joint 9F number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. - Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury I . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job Truss Truss Type (sty Ply Centex Homes,'Model 1702 A X06.009 EJ7A MONO TRUSS 2 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, A. 34946 6.300 s Dec 12005 MiTek Industries?i WGIVIon Oct 30 11:54:08 2006 Page 1 0-0-0 o-M 6-0-0 6-M 3 Scale=1:19.' 5.00 12 2 1 4 z-10-10 0.0.0 3x7 11 0-M 6-M r 6-M Plate Offsets X,Y : 1:0-2-0,0-3-9 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.56 Vert(LL) -0.07 1-4 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.33 Vert(TL) -0.16 1-4 >437 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Hofz(TL) 0.03 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 26lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 2 X 4 SYP No.2 pudins. SLIDER Left 2 X 6 SYP SS 3-3-11 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=26710-8-0, 3=208/Mechanical, 4=59/Mechanical Max Horz 1=131(load case 5) Max Uplift 1=-58(load case 5), 3=-140(load case 5) Max Grav 1=267(load case 1), 3=208(load case 1), 4=119(load case 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-83/0, 2-3=-64/63 BOT CHORD ' 1-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category Il; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) "This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ,3) All plates are-3x4-MT20 unless otherwise indicated. _----------- - - - 4) Refer to girder(s) for truss to truss connections. 5) ,Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 lb uplift at joint 1 and 140 lb uplift at joint 3. LOAD CASE(S) Standard , Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - VerVy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - nottruss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, will53719. Symbols PLATE LOCATION AND ORIENTATION 13/, *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. O *For 4 x 2 orientation, locate plates 0 - 1/16" from outside o_ edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but LiH_' reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Compopent Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ConnectedFWood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties, O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 EJ7U MONO TRUSS 12 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. hOW10ct 3011:54:08 20136 Page 1 0-M 7-M 7-M 3 Scale = 1:19: a 5.00 12 2 1 3x4 = 4 2040-00 0-0-0 3x6 II 1r -0 0 114-01 - 7.0-0 ` 1-M 0-0-0 5." Plate Offsets X, 5:0-1-11,0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (lac) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.39 Vert(LL) -0.04 4-5 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.26 Vert(TL) -0.11 4-5 >604 180 BCLL 10.0 Rep Stress lncr YES WB 0.03 Horz(TL) 0.04 3 n/a n/a BCDL , 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 22lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or.6-0-0 oc BOT CHORD 2 X 4 SYP No.2 pudins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=174/Mechanical, 4=64/Mechanical, 5=386/0-8-0 Max Horz 5=131(load case 5) ` Max Uplift 3= 110(load case 5), 5=149(load Case 5) Max Grav 3=174(load case 1), 4=104(load case 2), 5=386(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-154/56, 2-3=-84/52 BOT CHORD 1-5=-0/131, 4-5=b/O WEBS 2-5=358/228 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been -designed for a 10.0 psf bottom chord live load nonconcurrent with any other, live -loads. _--- - — - 3) Refer to girder(s) for truss to truss connections. 4),Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 3 and 149 lb uplift at joint 5. LOAD CASE(S)_ Standard. Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, �r•0 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component MiTek, Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-'hd 0 cc O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside 0 edge of truss. P *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but `iF reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. , BCSI1: Building .Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Mvfal Plate Connected�Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERSAETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 0 T:E�EL�OIC} AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11, Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06-009 EJ8 SPECIAL 2 1 Job Reference (opton Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 4�P.08 20016 Page 1 G-0-0 1 4-10-8 5-10-8 8-M • i 4-10-8 1-M 2-1-8 5 ' Scale = 1:17.. e ° 4x6 = 4x6 = 3 4 5.00 12 2 N 1 3x4 = 2010-00 0 -0 8 7 6 2-" 24-10-8 5-10-8 8-0-0 2-" 0-4-0 2-6-8 14)-0 2-1.8 Plate Offsets X,Y : 4:0-2-12,0-2-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl t/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.25 Vert(LL) 0.04 8 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.26 Vert(TL) -0.09 7-8 >774 180 BCLL 10.0 Rep Stress Incr YES WB 0.03 Horz(TL) -0.02 5 n/a n/a BCDL 10.0 Code FBC2004frPI2002 (Matrix) Weight: 31 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 2 X 4 SYP No.2 purtins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 5=133/Mechanical, 6=76/Mechanical, 9=506/0-8-0 Max Horz 9=131(load case 5) Max Uplift 5=72(load case 5), 6=-16(load case 6), 9=-236(load case 5) Max Grav 5=133(load case 1), 6=81(load case 2), 9=506(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=121/45, 2-3=73/0, 3-4=-38/0, 4-5=34/45 BOT CHORD 1-9=0/124, 8-9=-9/6,-7-8=-3/3, 6-7=0/0 WEBS 2-9=-303/153, 3-8=-88/95, 4-7=-40/41 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber D0L=1.60 plate grip DOL=1.60. 3 Provide adequate drainage -to prevent water poniiing. - " - - 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 72 lb uplift at joint 5, 16 lb uplift at joint 6 and 236 lb uplift at joint 9. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lie #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. 14515 N. Outer Forty, Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component Safety D'Onofrio Drive, Madison, WI 53719. MiTek Information available from Truss Plate Institute, 583 Symbols PLATE LOCATION AND ORIENTATION 13/14 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-1/16" O *For 4 x 2 orientation, locate plates 0 - 1/16" from outside o_ edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building ,Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ConnectedWood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e,g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® f Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A r X06.009 EJ8A SPECIAL 1 1 ' Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon 04P@M 1:54:08 20D►6 Page 1 0-" 6-2-4 6-24 1-0-0 0-9-12 Scale=1:19., 4x6 = 4x6 = 5 3 4 5.00 12 4 2 N 1 3x4 = 2%0-W 8 7 6 I 2-M I 6-2-4 - 24)-0 4-2-4 1-9-12 Plate Offsets X, 4:0-2-4,0-2-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.27 Vert(LL) 0.03 8-9 >999 360 MT20- 244/190 , TCDL 15.0 Lumber Increase 1.25 BC 0.27 Vert(TL) -0.07 8-9 >949 180 BCLL 10.0 Rep Stress Incr YES WB 0.04 Horz(TL) -0.02 6 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 33lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 5=196/Mechanical, 6=13/Mechanical, 9=506/0-8-0 Max Horz 9=131(load case 5) Max Uplift 5=-101(load case 5), 9=-236(load case 5) Max Grav 5=196(load case 1), 6=33(load case 4), 9=506(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2= 114/31, 2-3=-95/0, 3-4=11/0, 4-5=-41/72 BOT CHORD 1-9=0/115, 8-9=17/23, 7-8=z8/11, 6-7=0/0 WEBS 3-8=-210/162, 2-9=-323/179,4-7=149/205 NOTES _ 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2pst BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right Exposed ; Lumber DOL=1.60 plate grip DOL=1.60. _ — --- — -- — 3) Provide adequate drainage to prevent water ponding. 4),*This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift at joint 5 - and 236 lb uplift at joint 9. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lie #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verijy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. S} ite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTek safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 M O *For 4 x 2 orientation, locate plates 0 -'/16" from outside o edge of truss. R *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSII : Building component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363; 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required, See BCSII . 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. IL 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection, 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements, 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise. © 2004 Mitee Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 F01 FLOOR 4 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:09 2006 Page 1 GA-8 • F I �� 1310 2-0-0 Orb 1 p �'�� �� 0Cale ~�I �r S le=1:47.: r �M 46 = 4x6 11 1.5x4 11 1.5x4 11 3x6 FP = 46 = 1.5x4 11 1.5x4 It Us 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 I� 32 31 30 29 28 27 26 25 24 23 22 21 20 19 1.5x4 11 4x6 = 4x6 = 3x6 FP = 3x7 = 1.5x4 11 4x6 = 1-5.0 0-0'0 1-&0 Or4 8 6-11-2 7-11-2 8-11-+ lls-" 20-9-6 22-9-0, 26-11.8 27A.0 121-9-6 • 0-1-0 6510 140-0 1-0-0 7-0-14 4-9.6 14)-0 140-0 4-2-2 0.4-8 Plate Offsets X,Y : 1:0-3-0,Ed e , 18:0-3-0,Edge], 21:0-1-8,Ed e , 22:0-1-8,Ed e , 28:0-1-8,Ed e , 29:0-1-8,Ed e, 32:Ed e,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.62 Vert(LL) -0.10 29-30 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.59 Vert(TL) -0.15 29-30 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.21 Horz(TL) -0.03 18 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 151 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 4 X 2 SYP No.2 pudins,. except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 1=768/0-4-0, 18=474/0-4-0, 24=1668/0-8-0 Max Grav 1=795(load case 7), 18=536(load case 3), 24=1668(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-32=0/8,18-19=-11/0, 1-2=-599/0, 2-3=-595/0, 3-4=1431/0, 4-5=-1838/0, 5-6=1838/0, 6-7=1838/0, 7-8=1473/0, 8-9=-1473/0, 9-1 0=-681/39, 10-11=0/994, 11-12=0/994, 12-13=-414/314, 13.14=825/33, 14-16= 825/33, 15-16=-825/33, 16-17=-371/0, 17-18=376/0 BOT CHORD 31-32=0/0, 30-31 =0/1 123, 29-3d=Q/l711, 28-29=0/1838, 27-28=0/1749, 26-27=0/1186, 25-26=238/158, 24-25=-238/158, 23-24=463/105, 22-23=161/710, 21-22=-33/825, 20-21=0/684, 19-20=0/0 WEBS 5-29=-184/7, 6-28=-405/0, 11-24=-93/0, 14-22=-341/0, 15-21=-138/60, 1-31=0/896, 3-31=-838/0, 3-30=0/489, 4-30=-446/0, 4-29=-64/314, 10-24=-1193/0, 10-26=0/883, 9-26=-849/0, 9-27=0/501, 7-27=501 /0, 7-28=0/562, 12-24=-898/0, 12-23=0/571, 13-23=583/0, 13-22=0/511, 18-20=0/559, 1ti-20=-496/0, 16-2-1-=-121/203 NOTES 1 j Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 25 and 8. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. Seng-Chaff Tan, FL Lic #46765 6) CAL,lTION, Do not erect truss backwards. 345 Alhambra PL West Palm Beach, FL 33405 LOAD CASE(S) Standard MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - VeriVy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 M![ is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component O M k Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. ITe Symbols PLATE LOCATION AND ORIENTATION Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-'/0 *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected:Wood Trusses. 0 X O U o_ O R Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 F02 FLOOR 2 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:09 2006 Page 1 04-8 H�-I 2-"���� 2-"�I �-5-2 0 ' Sbale=1:47.: 5x5 = 46 11 1.5x4 11 1.5x4 11 3x6 FP = 4x6 = 1.5x4 11 1.5x4 11 3x5 11 1 2 3 4 5 6 7 8 9 10 11 12 1314 15 16 17 18 " I 32 31 30 29 28 27 26 25 24 23 22 21 20 19 1.5x4 11 4x6 = 3x6 FP = 3x7 = 5x5 = 1.5x4 11 4x6 = 1-5-0 0.0-0 1-5-0 0,4-B 6-11-2 8-11-2 i 16-5.8 20-9-6 �21_9-6Ti 2s-11-8 44.0 17-11-2 04-8 6-fr10 1-0-0 1-0-0 7-6-6 4-3-14 1-0-0 1-0-0 4-2-2 0-4-8 Plate Offsets X, 1:0-3-0,Ed e , 18:0-3-0,Ed e , 21:0-1-8,Ed e , 22:0-1-8,Ed e , 28:0-1-8,Ed e , 29:0-1-8,Ed e , 32:Ed e,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deli Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.69 Vert(LL) -0.11 29-30 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.57 Vert(TL) -0.15 29-30 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.21 Horz(TL) -0.03 18 n/a n/a BCDL 5.0 Code FBC2004/TPI2002 (Matrix) Weight:151 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 4 X 2 SYP No.2 purlins, except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (lb/size) 1=795/0-4-0, 18=442/0-4-0, 24=1674/0-5-8 Max Grav 1=816(load case 7), 18=517(load case 3), 24=1674(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-32=0/8, 18-19= 13/0, 1-2=-618/0, 2-3=-614/0, 3-4=-1481/0, 4-5=-1940/0, 5-6=1940/0, 6-7=1940/0, 7-8=4 51310, 8-9=4 513/0, 9-10=672/0, 10-11 =0/1 004,11-12=0/1004, 12-13=-419/369, 13-14=763/99, 14-15=-763/99, 15-16=763/99, 16-17=356/0, 17-18=-361/0 BOT CHORD 31-32=0/0, 30-31=0/1158, 29-30=0/1188, 28-29=0/1940, 27-28=0/1805, 26-27=0/1202, 25-26=223/126, 24-25=-223/126, 23-24=-527/133, 22-23=-195/702; 21-22=-99/763, 20-21=0/652, 19-20=0/0 WEBS 5-29=-213/0, 6-28=-297/0, 11-24=-97/0, 14-22=561 /0, 15-21=-115/82, 1-31=0/925, 3-31=-864/0, 3-30=0/514, 4-30=477/0, 4-29=-27/371, 10-24=-1222/0, 10-26=0/913, 9-26=882/0, 9-27=01531, 7-27=-514/0, 7-28=0/486, 12-24=-867/0, 12-23=0/555, 13-23=-594/0, 13-22=0/712,18-20=0/537, --. 16-20=-469/25, 16-21=-166/160"-" - "- NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. = 3) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 25 and 8. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ' 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. Seng-Chai Tan, FL Lic #46765 6) CALITION, Do not erect truss backwards. 345 Alhambra PL West Palm Beach, FL 33405 LOAD CASE(S) Standard MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 El Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DS"9 and BCSII Building Component 0 MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated, 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required, See BCSII , 0-t/ie„ 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 c2-3 materials on inadequately braced trusses. oa, 4 3. Provide copies of this truss design to the building O designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate m v �,� 33 Z other interested parties. plates 0 - 1/16" from outside O a- �� U 4. Cut members to bear tightly against each other. edge of truss. o- 5. Place plates on each face of truss at each joint and c7-e cc -a css embed fully, Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated byANSI/TPI1, required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MITek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11, Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings U14 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior lip reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate B © 2004 WOO Connected Wood Trusses. Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 F03 FLOOR 8 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Ff. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:10 2006 Page 1 o-4-8 - H 1.3-0 I 1-31� 20-0 0 I Scale=1:28.' 4x6 II 1.5x4 II 4x6 = 1 2 3 4 5 6 5x5 7 8 9 18 17 16 15 14 13 12 11 1 1.5x4 II 4x6 = 1.50 II 4x6 = 5x5 = 1-5-0 0-0-0 R±1 6-11-2 7-11-2I B-11-2 15-10-1 -04-8 6�10 1-" 1-M 6-11-2 Plate Offsets X,Y : 1:0-3-0,Ed e , 6:0-1-8,Ed e , 15:0-1-8,Ed e , 18:Ed e,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.45 Vert(LL) -0.10 14 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.74 Vert(TL) -0.15 14 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.23 Horz(TL) 0.01 10 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 89lb. LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 4 X 2 SYP No.2 purlins, except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 10=841/Mechanical, 1=841/0-4-0 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-18=0/7, 9-10=-836/0, 1-2=-640/0, 2-3=636/0, 3-4=1540/0, 4-5=-2059/0, 5-6=-2059/0, 6-7=-2028/0, 7-8=1562/0, 8-9=-652/0 BOT CHORD 17-18=0/0, 16-17=0/1198, 15-16=0/1864, 14-15=0/2059, 13-14=0/2059, 12-13=0/1874, 11-12=0/1229, 10-11=0/0 WEBS 5-15=-251/0, 6-14=-296/247, 1-17=0/958, 3-17=893/0, 3-16=0/542, 4-16=-515/0, 4-15=0/492, 9-11=0/980, 8-11=915/0, 8-12=0/529, 7-12=-496/0, 7-13=0/390, 6-13=485/220 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) Refer to girder(s) for truss to truss connections. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top'ehord bearing and first diagonal or vertical web shall not exceed 0.500in. 1 6) CAUTION, Do not erect truss backwards. ` LOAD CASE(S) Standard Seng-Chai Tan, FL Lic #46765 345 Alhambra PL • West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, �® Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information avallable from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/n *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e,g. diagonal and securely seat, or X-bracing, is always required, See BCSI1, 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 c2-a materials on Inadequately braced trusses. o WEBS c3� 4 3. Provide copies of this truss design to the building cc designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate �,� �,�� 9 other interested parties. plates 0 - 1/16" from outside O o �A6 U 4, Cut members to bear tightly against each other, edge of truss. a- 5. Place plates on each face of truss at each joint and C7-8 cea os-e Of embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6, Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43,96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings U14 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint LiHJ approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, , Installing & Bracing of Metal Plate © 2004 Miteko Connected.Wood T4usses. Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 F04 FLOOR 8 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries,Inc. Mon Oct 3011:54:10 2006 Pagel a4-B • i i 13-0 1-5-2 2-M -, ; o-sz� ' stele = 1:18 3x5 11 3x4 = 3x4 = 1.5x4 11 1.5x4 11 4x6 = 3x4 = 3x4 11 1 2 3 4 5 6 7 8 14 13 12 11 4x6 = 10 9 1.5x4 11 3x4 = 3x4 = 3x4 = - 3x5 = 1$0 0-M 0.4.81 4.6-10 56-10 6-6.10 11-1A 1 F GA-8 4-2-2 1.0.0 1-" 4.6-10 Plate Offsets X,Y : 1:0-3-0,Ed e , 9:0-2-0,Edge], 11:0-1-8,Ed e , 12:0-1-8,Edge], 14:Ed e,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.34 Vert(LL) -0.05 10-11 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.35 Vert(TL) -0.06 10-11 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.14 Horz(TL) 0.01 9 n/a n/a BCDL 5.0 Code FBC2004/TPI2002 (Matrix) Weight 64lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 4 X 2 SYP No.2 purlins, except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 9=580/Mechanical, 1=580/0-4-0 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-14=-2/11, 8-9=-38/0, 1-2=408/0, 2-3=-403/0, 3-4=-967/0, 4-5=-967/0, 5-6=-967/0, 6-7=-723/0, 7-8=0/0 BOT CHORD 13-14=0/0, 12-13=0/756, 11-12=0/967, 10-11=0/945, 9-10=0/474 WEBS 4-12=-217/0, 5-11=-280/65, 1-13=0/607, 3-13=-560/0, 3-12=0/404, 7-9=-712/0, 7-10=0/395, 6-10=-353/0, 6-11=-113/348 NOTES 1) Unbalanced floor live loads have been considered for this design. , 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 5) CAUTION, Do not erect truss backwards. - --- -- - LOAD CASE(S) Standard Seng-Chaff Tan, FL Lie #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Ver N design parameters and READ NOTES ON TRIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown 14515 N. Outer Forty, r•O Suite #300 Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component MiTek° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/, *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 ir 0 * For 4 x 2 orientation, locate 3: plates 0 - 1/16" from outside o edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ' ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Desigh Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury l . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all Cc other interested parties. 0 U 4. Cut members to bear tightly against each other. 0 5. Place plates on each face of truss at each joint and embed fully Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. ' I © 2004 Mitek® Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06-009 F05 FLOOR 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:10 20D6 Page 1 04-0 1-5-12 2-0-0 0.5.4 1-3-0 _ = ~� 3x51 11 3x4 = 1.5x4 1I 1.5x4 II 1 Scale 1:13.: - 1 2 3 11 4 5 4x6 = 6 3x4 11 4 T 4x6 = _ 10 9 8 7 1.5x4 II 3x4 = 1.&0 3x5 9-" ,r04.0 2-0-12 3-0-12 4-0-12 6-1-8 . 1 i 0-4-0 14612 1-M 1-M 2-0-12 Plate Offsets X, 1:0-3-0,Ed e , :0-2-0,Ed e , 8:0-1-8,Ed e , 9:0-1-8,Ed e LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.22 Vert(LL) -0.01 8 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.14 --Vert(TL) -0.02 8 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.08 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 38lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 4 X 2 SYP No.2 pudins, except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 7=308/Mechanical, 1=308/0-3-8 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-10=-4/10, 6-7=-57/0, 1-2=263/0, 2-3=261/0, 3-11=-261/0, 4-11=-261/0, 4-5=-261/0, 5-6=0/0 BOT CHORD 9-10=0/0, 8-9=0/261, 7-8=0/214 WEBS 3-9=-211/0, 4-8=191/0, 1-9=0/355, 5-7=322/0, 5-8=0/232 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 5) CAUTION, Do not erect truss backwards. — -- - -- LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL _ West Palm Beach, FL 33405 MTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component O M safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. I e Symbols PLATE LOCATION AND ORIENTATION 13/a * Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside a. edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT The first dimension is the width NUMBERS/LETTERS. 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A BEARING Indicates location where bearings U14 (supports) occur. Icons vary but LiH-J reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling; Installing & Bracing of Metal Plate Connected Wood Tresses. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII . 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all Cc other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitee Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 F06 FLOOR 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:10 2006 Page 1 0-4-0 1 1-3-0 1 0.10-6 2.0.0 , 1-1-0 3x5 11 3x4 - 3x4 = 3x5 — Scale=1:13.! 1 2 3 4 3x4 = 5 4 ci R = 11 10 9 8 7 3x4 6 1.5x4 11 3x4 = 1.5x4 11 1.5x4 11 1-5-0 3xm-0}0 0d-0 i 2-B-B 3-6-0 4-8-8 7-5-0 ' 0-4-0 2-4-8 1-041 1.0.0 2-8-8 Plate Offsets X, 1:0-3-0,Ed e , 3:0-1-8,Ed e , 4:0-1-8,Ed e , 5:0-2-0,Ed e LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Lld PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.30 Vert(LL) -0.03 8 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.31 Vert(TL) -0.03 8 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.08 Horz(TL) 0.02 6 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 45lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 4 X 2 SYP No.2 purlins, except end verticals. WEBS 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 6=379/Mechanical, 1=379/0-3-8 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-11=0/13, 5-6=-375/0, 1-2=-246/0, 2-3=-243/0, 3-4=-416/0, 4-5=-240/0 BOT CHORD 10-11=0/0, 9-10=0/416, 8-9=0/416, 7-8=0/416, 6-7=0/0 WEBS 3-9=35/117, 4-8=-71/62, 1-10=0/365, 3-10=334/0, 5-7=0/360, 4-7=295/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Refer to girder(s) for truss to truss connections. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Fatty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 c TEE-LOK mUmmam 0 m O U O AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1, Additional stability bracing for truss system, e.g. diagonal or X-bracing, Is always required, See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. ' I © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 FG1 SPECIAL 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:11 20136 Page 1 3-5-8 6-7-5 104-15 13-&12 17.0-4 r 1 I 3-5-8 3-1-13 3-9-10 3-1-13 3-5-8 Scale=1:28.. TOP 3x4 II 4x14 = 3x7 = 1.5x4 II 1.5x4 II 414 = 3x4 II 1 2 3 4 5 6 7 15 13 16 12 17 18 11 19 10 20 9 21 5x8 = 2x5 11 5x5 = 5x5 = 5x10 MT18H = 2x5 II 5x8 = 0-M 0-0-0 3-5-8 6-7-5 104-15 13-6-12 17-0-4 3-5-8 3-1-13 3-9-10 3-1-13 3-5-8 Plate Offsets X, 2:0-5-0,0-2-0 , 6:0-5-8,0-2-0 , 11:0-1-12,0-2-12 , 12:0-1-12,0-2-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.92 Vert(LL) -0.34 11-12 >583 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.91 Vert(TL) -0.52 11-12 >379 240 MT18H 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.59 Horz(TL) 0.08 8 n/a n/a BCDL 5.0 Code FBC2004ITP12002 (Matrix) Weight: 278lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 3-2-2 oc T2 2 X 4 SYP No.1 pudins, except end verticals. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 *Except* W32X6SYP SS, W32X6SYP SS REACTIONS (lb/size) 14=6685/0-8-0, 8=6343/0-3-8 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-14=-33810, 1-2=-150810, 2-3=-20233/0, 3-4=20233/0, 4-5=20233/0, 5-6=20233/0, 6-7=-1497/0, 7-8=349/0 BOT CHORD 14-1 5=0/1 3439, 13-15=0/13439, 13-16=0113439, 12-16=0/13439,'12-17=0/20233,17-18=0/20233, 11 -1 8=0/20233, 11-19=0/13316, 10-19=0/13316, 10-20=0/13316, 9-20=0/13316, 9-21=0/13316, 8-21=0/13316 WEBS 2-14=-1284910, 2-13=0/1909, 2-12=0/7480, 4-12=-331/0, 5-11=360/0, 6-11=0/7612, 6-9=0/1841, 6-8=12730/0 NOTES -- 1) 3-ply truss to be connected together with 10d (0.131 "x3") nails as follows: ,Top chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 oc. Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. ' 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. Seng-Chaff Tan, FL Lic #46765 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. 345 Alhambra PL Strongbacks to be attached to walls at their outer ends or restrained by other means. West Palm Beach, FL 33405 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 570 lb down at MiTek Industries, Inc. 1-2-12, 831 lb down at 1-2-12, 570 lb down at 3-2-12, 831 lb down at 3-2-12, 570 lb down at 5-2-12, 831 lb down FL Cert.#6634 October 30,2006 1! I{Y /C, th Df SI- n' 61' FL 'drib 58fiTi�MiRk 0drifietiO}3'!�fl f5'tl✓� r� d ti 4�1L�F� �fl�r � � � 11ft�rtg�omponent. 14515 N.Outer Forty, Suite #300 Pf���9B�t4l8�if�At�8r5tneters and proper incorporation of component Is responsibility of building designer -not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during consfruction Is the responsibility of the L �qr.� alb t bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding iaUrico on, qC�a^ty con'}ro`f,'s`torage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DS"9 and BCSII Building Component MiTek safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719, Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4. X 4 perpendicular to slots. Second dimension is the length parallel to slots. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO BEARING SBCCI Indicates location where bearings U14 (supports) occur. Icons vary but reaction section indicates joint 9F number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 96-31, 95-43, 96-20-1, 96-67, 84-32 4922, 5243, 5363, 3907 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all m other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11, Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise. © 2004 MiteO , Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 FG1 SPECIAL 1 3 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:11 2006 Page 2 LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-7=100, 8-14=-10 Concentrated Loads (lb) Vert: 13=-1 401 (F=831, B=-570) 15=-1 401 (F=-831, B=-570) 16=-1 401 (F=831, B=-570) 17=-1 401 (F=-831, B=-570) 18=-1 401 (F=-831, B=-570) 19=-1 401 (F=831, B=-570) 20=-1401(F=-831, B=-570) 21 =-1 401 (F=-831, B=570) A WARNING - Vergy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths .Personal Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e,g, diagonal and securely seat. or X-bracing, is always required, See BCSII . 1 2 3 TOP CHORDS 2, Never exceed the design loading g g shown and never stack c1-2 cz-a materials on inadequately braced trusses. WEBS ca-4 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate N other interested parties. plates 0 - 1/16" from outside truss. a. �a� U 4. Cut members to bear tightly against each other. edge of 0 5. Place plates on each face of truss at each joint and c7-8 06-7 ce-s embed fully. Knots and wane atjoint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated b symbol shown and/or y y BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings U14 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior Lip reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek@ DSB-89: Design Standard for Bracing, BCSII : Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 MiteV Connected Wood Trpsses. Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 FG2 FLOOR 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946 6.300 s Dec 12005 MTek Industries, Inc. Mon Oct 30 11:54:11 2006 Page 1 0-4-8 I 0F61� Wi H 1-3-0-00 Cale =1:47.: 3x4 = 46 = 5x6 = 700 MT18H = 3x5 11 5x6 II 4x6 = 3x6 = 3x4 = 46 = 3x6 FP = 3x4 11 5x5 = 5x10 = 3x4 = 3x4 = 3x4 - 1 2 3 4 5 6 34 35 7 8 9 10 11 12 1336 14 15 16 17 L NINA V I 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 1.5x4 11 5x5 = 4x6 = 500 = 46 = 46 = 1.5x4 11 3x6 FP = 5x8 = 3x6 = 3x4 = 3x4 = 1.5x4 11 6x8 = 5x5 = 4x6 = 1-5-0 0-0'0 1-5-0 0r4-6 6-2-4 16.5-0 19-10-4 26-11-8 27- ,4 - 1 0-0-8 5.9-12 10-2-12 3-5-4 7-1.4 0-4-8 Plate Offsets X, 1:0-3-0,Ed e , 12:0-2-4,Ed e , 17:0-3-0,Ed e , 23:0-2-4,Ed e , 32:0-2-4,Ed e , 33:Ed e,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.97 Vert(LL) -0.13 29-30 >999 480 MT20 2441190 TCDL 10.0 Lumber Increase 1.00 BC 0.84 Vert(TL) -0.19 29-30 >999 240 MT18H 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.45 Horz(TL) -0.02 17 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 171 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 'Except* TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc T3 4 X 2 SYP No.1 pudins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 1=1182/0-4-0, 17=296/0-4-0, 24=3723/0-5-8 Max Uplift 17=-115(load case 2) Max Grav 1=1214(load case 2), 17=533(load case 3), 24=3723(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-33=0/4, 17-18=0/4, 1-2=-961/0, 2-3=-957/0, 3-4=-2461/0, 4-5=-3337/0, 5-6=-3337/0, 6-34=-3080/0, 34-35=3080/0, 7-35=3080/0, 7-8=2011/0, 8-9=2011/0, 9-10=0/651, 10-11: 0/3283, 11-12=0/3283, 12-13=221/1439, 13-36=-762/853, 14-36=762/853, 14-15=782/425, 15-16=-369/120, 16-17=-374/120 BOT CHORD 32-33=010, 31-32=0/1813, 30-31=0/3091, 29-30=0/3384, 28-29=0/2754, 27-28=35/1212, 26-27=35/1212, 25-26=1553/0, 24-25=-1553/0, 23-24=-2129/0, 22-23=-1002/692, 21-22=-1002/692, 20-21=-623/855, 19-20=-247/689, 18-19=0/0 WEBS 5-30=-26/81, 11-24=-217/0, 13-22=0/445, 1-32=0/1442, 3-32=-1360/0, 3-31=0/1029, 4-31=-999/0, 4-30=0/601, 10-24=-2598/0, 10-26=0/1959, 9-26=-1978/0, 9-27=0/9, 9-28=0/1274, 7-28=1221/0, 7-29=0/776, 6-29=-741/0, 6-30=-127/249, 12-24=-2047/0, 12-23=0/1488, 13-23=-1281/0, 17-19=-181 /557, 15-19=-508/202, 15-20=-282/148, 14-20=116/316, 14-21=-565/0, 13-21=0/519 ' NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are MT20 plates unless otherwise indicated. 3) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 25 and 8. Seng-Chaff Tan, FL Lic#46765 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 115 lb uplift atjoint 17. 345 Alhambra PL 5) Load case(s) 4 hasthave been modified. Building designer must review loads to verify that they are correct for the West Palm Beach, FL 33405 intended use of this truss. MiTek Industries, Inc. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. FL Cert.#6634 October 30,2006 f fgq p,���q�1 READ NOT 3 ON THIS AND REVERSE SIDE BEFORE USE. ��I��ihis esign is bQsed onl pon parameters shown, and is f r an�� i��}}d--'44vi�1yy�� I uildin component. Suite N. Outer Forty, Suite /f300 9)PaRd96 rpN,1411 &Ki��r6dc�r�ISfft�t#f �9fit4i�158��A�IW#}u`i9@ing shown Chesterfield, MO 63017 Is@9241 the)onsibility of the ef�rM910 i1f ent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding r on, torn e de�i,v,e,,r� erec?jo��n�Qn� br in cpj�s,uit ANSI/TPI1 Q li Cr' eri 9 a B 1 Building Component 1 asron`� �or b�'�c �. n ft�rF( PttRL h iYl� 983 6�n d}Iv1'!�vl�it�i3rla f. M i Te k Symbols PLATE LOCATION AND ORIENTATION -01 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 cc * For 4 x 2 orientation, locate v plates 0 -1/16" from outside edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings Uk (supports) occur. Icons vary but L�:e reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Compot)ent Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected,Wood Trusses, Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 TEE-LOK 0,1MM,M AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. a- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 1.6. Install and load vertically unless indicated otherwise. © 2004 MiteV ; Job Truss Truss Type Oty Ply Centex Homes, Model 1702 A X06.009 FG2 FLOOR 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:11201366 Page 2 LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 ` Uniform Loads (plf) Vert: 18-33=-10, 1-5=-100, 5-13=-200, 13-17=-100 Concentrated Loads (lb) Vert: 22=-462(F) 30=-462(F) 4) 1st chase Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 18-33=-10, 1-5=-100, 5-35=200, 11-35=-47, 11-13=-200, 13-17=-100 Concentrated Loads (lb) Vert: 22=462(F) 30=-462(F) A WARNING - verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, �® Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite 4l300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSIi Building Component O M Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. ITe Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property �3/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI 1. TOP CHORDS 2. Never exceed the design loading shown and never stack C1-2 C2-3 materials on inadequately braced trusses. WEBS ¢,� 4 3. Provide copies of this truss design to the building m designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate 0 �,� ��� o other interested parties. plates 0 - 1 /16" from outside edge of truss. O �a6 19 U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and C7-8 Cea css embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6, Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20M not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. �Su (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior L��F reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction. MlTeke DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate , © 2004 Mitee Connected Wood Trjusses. Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06-009 FG3 SPECIAL 2 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. 0-0-0 Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. 3x4 = TOP 2 1.Sx4� 34-12 Mon Oct 3011:54:12 2006 Page 1 34-12 Scale=1:10.: Ll 0'r U6 — 5 3 I Pus II 34-12 34-12 LOADING (psf) TCLL 40.0 SPACING 2-0-0 Plates Increase 1.00 CSI TC 0.63 DEFL in (loc) I/defl Ud Vert(LL) -0.01 3-4 >999 480 PLATES GRIP MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.18 Vert(TL) -0.01 3-4 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 20lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-12 oc BOT CHORD 2 X 6 SYP SS purlins, except end verticals. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 4=549/0-1-8, 3=472/Mechanical FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-4=-310/0, 1-2=0/0, 2-3=310/0 BOT CHORD 4-5=0/0, 3-5=0/0 WEBS 1-3=0/0 NOTES 1) Refer to girder(s) for truss to truss connections. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails: Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 369 lb down at 1-4-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1),Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-2=-200, 3-4=-10 Concentrated Loads (lb) Vert:5=-369(F) Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL ' West Palm Beach, FL 33405 MiTek Industries, Inc. FL CertX6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valld for use only with MFek connectors. This design Is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTek° safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719, Symbols PLATE LOCATION AND ORIENTATION 13/, *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate Plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building,Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected.Wood Russes. O U a �L Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1, 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for .use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitee Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06-009 GE1 GABLE 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:12 2006 Page 1 0-M 10-8-12 10-8.12 5 ' Scale = 1:25A 4 5.00 12 3 2 1 0-" 3A G 10-&12 10-&12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.16 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.11 Vert(TL) n/a - n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 6 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight 48lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins, except end verticals. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=148/10-8-12, 6=68/10-8-12, 7=204/10-8-12, 8=99/10-8-12, 9=368/10-8-12 Max Horz 1=184(load case 5) Max Uplift 6=31(load case 5), 7=-83(load case 5), 8=-43(load case 5), 9=-156(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-164/56, 2-3=-90/8, 3-4=-61/28, 4-5=32/18, 5-6=53/34 BOT CHORD 1-9=-2/3, 8-9=2/3, 7-8=2/3, 6-7=-2/3 WEBS 4-7=-156/97, 3-8=-89/60, 2-9=-263/159 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category ll; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. - - - 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 31 lb uplift at joint 6, 83 ,Ib uplift at joint 7, 43 lb uplift at joint 8 and 156 lb uplift at joint 9. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL " West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 W1 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. / MiTek Symbols PLATE LOCATION AND ORIENTATION 14- l3/14 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building,Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected,Wood Trusses. 0 Cc O U o_ O R Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 0 YEELOK� AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14, Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 HJ2 MONO TRUSS 2 1 ° Job Reference (optional)o e B Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:12 20Dr6 Page 1 0-0-o 4-0-13 3 4-0-13 scale = 1:9-: 2 4 3.54 F12 MTS16 Ll U4 = ' 6 4 041-2 5 04 3-9.4 , 4-0-13 , ' 3-9-4 0-3-9 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.54 Vert(LL) 0.00 5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.42 Vert(TL) 0.00 4-5 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.05 Horz(TL) -0.06 3 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 14Ib LUMBER BRACING TOP CHORD 2 X 4 SYP No.2' - TOP CHORD Structural wood sheathing directly applied or 4-0-13 oc BOT CHORD 2 X 4 SYP No.2 puffins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling, directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 3=335/Mechanical, 4=277/Mechanical, 5=952/0-11-5 Max Horz 5=54(load case 3) Max Uplift 3=-335(load case 1), 4=-277(load case 1), 6=601(load case 3) Max Grav 3=198(load case 3), 4=190(load case 3), 5=952(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=49/55, 2-3=109/56 BOT CHORD 1-6=0/54, 5-6=0/54, 4-5=0/0 WEBS 2-5=577/338 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other five loads. 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss conneci`iortis.� 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 335 lb uplift at joint 3, • 277 lb uplift at joint 4 and 601 lb uplift at joint 5. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)12 lb down and 20 lb up at 1-5-12, and 12 lb down and 20 lb up at 1-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) sectiori, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Seng-Chai Tan, FL Lic #46765 345 Alhambra PL Uniform Loads (pIf) West Palm Beach, FL33405 Vert: 1-3=-70, 1-4=-20 MiTek Industries, Inc. Concentrated Loads (lb) FL Cert.#6634 Vert: 6=20(F=10, B=10) October 30,2006 A WARNING - Verify design parameters and READ NOTES ON TSIs AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component MiTek® safety, Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/, *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1:. Building, Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected. Wood Trusses. 0 Cc O U O P Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2• Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all Cc other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and OP embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11, Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13• Bottom chords require lateral bracing at 10 ft, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06-009 HJ5 MONO TRUSS 1 1 Job Reference (optional), Universal Forest Product, Inc. E3 , t. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mo 30 11:54:12 20D8 Page 1 0-0-0 ` 2-5.5 5-7-14 2-5-5 3-2-8 Scale=1:14.1 3.54 F12 5 2 1 3x4 6 4 ' 2-0-12 3x6 11 0-0-0 5.7-14 ' 5-7-14 Plate Offsets X, 1:0-2-4,0-1-9 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.43 Vert(LL) 0.09 1-4 >784 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.24 Vert(TL) -0.10 1-4 >701 180 BCLL 10.0 Rep Stress Incr NO WB 0.00 Horz(TL) 0.02 3 n/a n/a BCDL 10.0 Code FBC20041TPI2002 (Matrix) Weight: 21 lb LUMBER - BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. SLIDER Left 2 X 4 SYP No.2 2-8-14 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=213/0-3-8, 3=169/Mechanical, 4=42/Mechanical Max Horz 1=93(load case 3) Max Uplift 1=-164(load case 3), 3=-117(load case 3), 4=-81(load case 3) Max Grav 1=213(load case 1), 3=169(load case 1), 4=94(load case 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=56/0, 2-5=-41/2, 3-5=40/36 BOT CHORD 1-6=0/0, 4-6=0/0 s, NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) ;This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for _truss to truss connections.__ 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 164 lb uplift at joint 1, 117 lb uplift at joint 3 and 81 lb uplift at joint 4. 5J Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2 lb down and 26 lb up at 4-3-11, and 2 lb down and 26 lb up at 4-3-11 on top chord, and 17 lb up at 4-3-11, and 17 lb up at t 4-3-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard • 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Seng-Chai Tan, FL Lie #46765 Uniform Loads (plf) 345 Alhambra PL - Vert: 1-3=70, 1-4=-20 West Palm Beach, FL 33405 Concentrated Loads (lb) MiTek Industries, Inc. Vert: 5=52(F=26, B=26) 6=28(F=14, B=14) FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, �® Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. I e Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Proper/ 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 0 -'/ib" 1 2 3 TOP CHORDS 2, Never exceed the design loading shown and never stack ci-z cz-s materials on inadequately braced trusses. o WEBS c3� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all *For4 x 2 orientation, locate �,� 3 �,�� other interested parties. plates 0 - /ib"from outside O U 4, Cut members to bear tightly against each other. edge of truss. a. 5. Place plates on each face of truss at each joint and c7-8 c6-7 C55 embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1, 7, Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber, PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or puriins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14, Connections not shown are the responsibility of others. �Su (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior Lie reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek® DSB-89: Design Standard for Bracing. BCSI1: Building,Companent Safety Information, Guide to Good Practice for Handling, ' Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Ttusses. Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 HJ7 MONO TRUSS 2 1 Job Reference o tional Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:12 POW Page 1 o-0-0 5-104 9-10-13 5-10-4 4-0-9 3 Scale = 1:19.f s 3.54 F12 8 2 7 1 LJ Li 9 6 10 54 1.5x4 11 2014"2 0-0-0 3x8 II 1-5-0 1-10-10 5-8-15 i 9-10-13 i • 1-5-0 0-5-11 3-10-5 4-1-13 Plate Offsets X,Y : 1:0-3-10,0-0-3 , 1:0-0-13,1-10-4 LOADING (psf) SPACING 2-0-0 CSI DEFL ip (foe) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.33 Vert(LL) -0.02 1-6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.36 Vert(TL) -0.07 1-6 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.22 Horz(TL) 0.01 4 n/a n/a BCDL 10.0 Code FBC2004ITP12002 (Matrix) Weight: 42lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP Not BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE Left: 2 X 6 SYP SS REACTIONS (lb/size) 3=124/Mechanical, 4=340/Mechanical, 1=409/0-11-5 Max Horz 1=131(load case 3) Max Uplift 3=-72(load case 3), 4=-123(load case 3), 1=128(load case 3) FORCES (lb) - Maximum Compression/Maximum Tension . TOP CHORD 1-7=-793/221, 2-7=714/235, 2-8=-64/3, 3-8=24/27 -, 'BOT CHORD 1-9=-308/713, 6-9=-308/713, 6-1 O=308/713, 5-10=-308/713, 4-5=0/0 WEBS 2-6=0/228, 2-5=-783/338 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL,=1.60 plate. grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4)'Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 72 lb uplift at joint 3,123 lb uplift at joint 4 and 128 lb uplift at joint 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)11 lb down and 42 lb, up at 4-3-11, 11 lb down and 42 lb up at 4-3-11, and 36 lb down and 42 lb up at 7-1-10, and 36 lb down and 42 lb up at 7-1-10 on top chord, and 22 lb down at 7-1-10, 22 lb down at 7-1-10, and 29 lb up at 4-3-11, and 29 lb up at 4-3-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Seng-Chai Tan, FL Lic #46765 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 345 Alhambra PL West Palm Beach, FL 33405 LOAD CASE(S) Standard MiTek Industries, Inc. 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 FL Cert.#6634 October 30,2006 Uniform Loads I Ai�tw1 parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valic�f� s� Out l �k roc is sl I�s�� 1v r11I4ar8 ar� shown, and Is for an individual building component. Applicability of domponerl} is building Suite #300 Chesterfield, MO 63017 of design ptlramefers and proper r Ihcorporbfion respbnsibirity of designer - not truss designer. Bracing shown W1 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required, See BCSI1, 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 cz-a materials on inadequately braced trusses. WEBS 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate O cc: other interested parties. plates 0 -1 /16" from outside O O �a� U 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-8 c6-7 ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. * Plate location details available in MiTek 20/20 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown Indicate minimum plating requirements, LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. Z�su (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior E�p reaction section indicates joint approval of a professional engineer. number where bearings occur. 16, Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building.Companent Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ® © 2004 Mitek® Connected -Wood TFusses. ' Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 HJ7U MONO TRUSS 4 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:12I?8WPage 1 o-0-0 ' 5104 9-10-13 • 510-4 4-0-9 3 Scale=1:19.( 3.54 12 8 2 7 Li Li 9 6 10 54 1.5x4 11 201,"2 04).0 3x8 II 1-5-0 5.8-15 i 9-10-13 11-10.10 ' 1-5-0 0-5.11 3-105 4-143 Plate Offsets X,Y : 1:0-3-10,0-0-3 , 1:0-0-13,1-10-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.33 Vert(LL) -0.02 1-6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.36 Vert(TL) -0.07 1-6 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.22 Horz(TL) 0.01 4 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 42lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDGE Left: 2 X 6 SYP SS REACTIONS (lb/size) 3=124/Mechanical, 4=340/Mechanical, 1=409/0-11-5 Max Horz 1=131(load case 3) Max Uplift 3=-72(load case 3), 4=123(load case 3), 1=128(load case 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP.CHORD 1-7=793/221, 2-7=-714/235, 2-8=64/3, 3-8=-24/27 BOT CHORD 1-9=-308/713, 6-9=308/713, 6-10=-308/713, 5-1 0=-308/713,4-5=0/0 WEBS' 2-6=0/228, 2-5=783/338 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf, Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcu-Trent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 72 lb uplift at joint 3, 123 lb uplift at joint 4 and 128 lb uplift at joint 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)11 lb down and '. 42 lb up at 4-3-11, 11 lb down and 42 lb up at 4-3-11, and 36 lb down and 42 lb up at 7-1-10, and 36 lb down and 42 lb up at 7-1-10 on top chord, and 22 lb down at 7-1-10, 22 lb down at 7-1-10, and 29 lb up at 4-3-11, and 29 lb up at 4-3-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Seng-Chai Tan, FL Lie #46765 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 345 Alhambra PL - West Palm Beach, FL 33405 LOAD CASE(S) Standard MiTek Industries, Inc. 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 FL Cert.#6634 October 30,2006 f parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. D s a bYuS I k ect sThis cles1 n is b s o�1(,�{Do'n� 1ar�me� (s shown, and is for an individual buildin cam anent. Appllcabilie�if��arlstSTa oaR��6f is respoRsltSllt�bf building designer- not truss designer. Bracing shown 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCS11 Building Component MiTek ® Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. -1�16n 0 O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside a edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building. Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ConnectedWood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 4wt TEE-LOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O v 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication, 8. Unless expressly noted, this design Is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified, 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14, Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06.009 MV2 VALLEY 1 - 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:13 2006 Page 1 0-0-0 2 � o 2-M 2- 5.00 12 Scale = 1:6.: 04 2-" 2,,3x4 i LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.02 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.01 Vert(TL) n/a - n/a 999 BCLL 10.0 Rep Stress Incr- YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 5lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=45/2-0-0, 2=35/2-0-0, 3=1012-0-0 Max Horz 1=24(load case 5) Max Uplift 1=9(load case 5), 2=-24(load case 5) Max Grav 1=45(load case 1), 2=35(load case 1), 3=20(load case 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-15/13 BOT CHORD 1-3=0/0 NOTES 1) Wind ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS;,cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Gable requires continuous bottom chord bearing. 4) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capabler-ofwithstanding9 lb uplift at -joint 1 and 24 lb uplift at joint 2. LOAD CASE(S) Standard Seng-Chai Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Proper/ 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c1-2 c2-s materials on inadequately braced trusses. WEBS cav 4 3. Provide copies of this truss design to the building IM designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate 6 �,� ��' 3 � other interested parties. plates 0 - 1/16" from outside 0 a �p� = 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and c7-8 csa ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPl 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. �Su (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16, Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, ` Installing & Bracing of Metal Plate © 2004 Mitek® ConnectedWood Trusses. " ' Job Truss Truss Type City Ply Centex Homes, Model 1702 A X06.009 MV3 VALLEY 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 30 11:54:13 2006 Page 1 0-0-0 2.8.12 r 2-8-12 Scale = 1:7: 5.00 12 Ll 2-8-12 x 2-8-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) n/a - n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 8lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-8-12 oc BOT CHORD 2 X 4 SYP No.2 puriins, except end verticals. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=66/2-8-12, 3=66/2-8-12 Max Horz 1=35(load case 5) Max Uplift 1=-13(load case 5), 3=-32(load case 5) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-22/19, 2-3=52/36 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE-.7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; ' MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. l 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 13 lb uplift at joint 1 and uplift attomt3. - :_----_----_—__ - LOAD CASE(S) Standard - r Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, �® Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component MiTek Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/*Center plate on joint unless a x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1, 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-z cz materials on inadequately braced trusses. WEBS c3� 4 3. Provide copies of this truss design to the building m designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate o I?` m other interested parties. plates 0 - 1/16" from outside O o �� U 4. Cut members to bear tightly against each other. edge of truss. CL 5. Place plates on each face of truss at each joint and c7-8 csa cs s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated byANSI/TPI1. required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MITek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified, by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. , Do not cut or alter truss member or plate without prior EV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek@ DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, MO Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses, Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 MV5 VALLEY 1 1 - Job Reference o tional -Pagel Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:13 2006 oa-o • 4-8-12 4.8-12 2 N Scale=1:11.( 5.00 F12 Ll 3x4 i 4-8-12 4-8-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.24 Vert(LL) n/a - n/a 999 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.14 Vert(TL) n/a - n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 16lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-8-12 oc BOT CHORD 2 X 4 SYP No.2 purlins, except end verticals. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1 =1 73/4-8-12, 3=173/4-8-12 Max Horz 1=72(load case 5) Max Uplift 1=-44(load case 5), 3=74(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-44/42, 2-3=-135/85 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-62; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 44 lb uplift at joint 1 and 74 lb uplift at joint 3.:------ LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI7 Building Component MiTek® safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719., Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/a *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat, or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2, Never exceed the design loading shown and never stack c1-z cz 3 materials on inadequately braced trusses. �*For WEBS c3� 4 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all 4 x 2 orientation, locate �,� 3 �,�� 3 cc other interested parties. plates 0 -/ie" from outside O a0 �� 2: 4. Cut members to bear tightly against each other. edge of truss. 5. Place plates on each face of truss at each joint and o7-8 cea cs s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 6. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimension's to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. - by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others, (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior IV reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. BCSI1: Building, Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 MV7 VALLEY 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI.34946 6.300 s Dec 12005 MiTek Industries, Inc. Mon Oct 3011:54:13 2006 Page 1 0-" 6-8-12 6-8-12 2 Scale=1:16.1 5.00 12 1 0-" 3x4 6.8.12 6-8-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.54 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.33 Vert(TL) n/a - n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 23lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-8-12 oc BOT CHORD 2 X 4 SYP No.2 purlins, except end verticals. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=263/6-8-12, 3=263/6-8-12 Max Horz 1=109(load case 5) Max Uplift 1=-66(load case 5), 3=-112(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-67/63, 2-3=-205/129 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1; 60. - . 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 66 lb uplift at joint 1 and 112 lb uplift. at -joint 3. — - - - --- — - — LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MITek Industries, Inc. FL Cert.#6634 October 30,2006 A WARNING - Verijy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with Mirek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only.Additlonal temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCS11 Building Component Safety Information available from TrussPlate Institute, 583 D'Onofrio Drive, Madison, WI 53719. MiTek° Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/4 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack 01-2 o2-3 materials on inadequately braced trusses, o WEBS �3b 4 3. Provide copies of this truss design to the building cc designer, erection supervisor, property owner and all * For 4 x 2 orientation, locate o ���� 3 W other interested parties. plates 0 -1/16" from outside O a0 �A� U 4. Cut members to bear tightly against each other. edge of truss, n 5. Place plates on each face of truss at each joint and 07-8 csa ce-s embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. _ required direction of slots in 8 7 6 5 b. Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT l 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. ' responsibility of truss fabricator. General practice 4 X 4 perpendicular to slots. Second is to camber for dead load deflection. , dimension is the length parallel 10. Plate type, size, orientation and location dimension to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or puriins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted, BEARING Indicates location where bearings U14 14. Connections not shown are the responsibility of others, (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior L�F reaction section indicates joint approval of a professional engineer. number where bearings occur. 16, Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, I Installing & Bracing of Metal Plate e © 2004 Mitek® Connected Wood Trusses. Job Truss Truss Type Qty Ply Centex Homes, Model 1702 A X06-009 MV9 VALLEY 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946 6.300 s Dec 12005 MTek Industries, Inc. Mon Oct 30 11:54:13 2006 Page 1 0-0-0 ' B-8-12 i 8-8-12 3 r Scale=1:21.f 5.00 12 1 Li 0-" 3x4 8.8-12 8--12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.26 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.15 Vert(TL) n/a - n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 33lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc BOT CHORD 2 X 4 SYP No.2 purlins, except end verticals. WEBS 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=137/8-8-12, 4=129/8-8-12, 5=442/8-8-12 Max Horz 1=147(load case 5) Max Uplift 4=-55(load case 5), 5=187(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=132/67, 2-3=-65/28, 3-4=-100/63 BOT CHORD 1-5=0/0, 4-5=0/0 WEBS 2-5=343/217 NOTES 1) Wind: ASCE 7-02; 130mph (3secondgust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4Gable requires -continuous bottom chord bearing. -- -- - - - - - - -- - - --- 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 55 lb uplift at joint 4 and 187 lb uplift at joint 5. LOAD CASE(S) Standard Seng-Chaff Tan, FL Lic #46765 345 Alhambra PL West Palm Beach, FL 33405 MiTek Industries, Inc. FL Cert.#6634 October 30,2006 e WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 M1 Is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DS11-89 and BCSI1 Building Component O M Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. ITe Symbols PLATE LOCATION AND ORIENTATION 13/4 * Center plate on joint unless x,y offsets are indicated. Dimensions are in fl-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 -1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING . Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: 'Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected, -Wood Trusses. 1. 0 cc O U d Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 cc O 2 U o_ O F- AGeneral Safety Notes Failure to Follow Could Cause Property Damage or .Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully, Knots and wane at joint locations are regulated by ANSI/TPI1, 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions" shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and 19.all respects, equal to or better than that specified, 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® ,