Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS_2KUniversal Forest Products RE: X06-016 CENTEX HOMES Site Information: Project Customer: CENTEX HOMES Lot/Block: 8A) Address: City: Model 2029 'B' DATE 04/05/07 PAGE 1 -.- - 1 Model: 2029'B' "mi" E Subdivision: • • • Lit, COPY eral Truss Engineering Criteria $ Design Loads (Individual Truss Design Drawings Show Special Loading Conditions Design Code: FBC2004/TP12002 Design Program: MiTek 20/20 6.3 Wind Speed: 120 mph Roof Load: 20.0-15.0-10.0-10.0 Floor Load: 40.0,10.0,0.0,5.0 1 1 X06-016 A01 04/05/07 26 X06-016 FG3 04/05/07 2 X06-016 A01A 04/05/07 27 X06-016 FG4 04/05/07 3 X06-016 A02 04/05/07 28 X06-016 GE1 04/05/07 4 X06-016 A03 04/05/07 29 X06-016 GE2 04/05/07 5 X06-016 A05 04/05/07 30 X06-016 HJ3 04/05/07 6 X06-016 A06 04/05/07 31 X06-016 HJ7 04/05/07 7 X06-016 A07 04/05/07 .32 X06-016 HJ7U 04/05/07 8 X06-016 601 04/05/07 33 X06-016 MV2 04/05/07 9 X06-016 B02 04/05/07 34 X06-016 MV4 04/05/07 10 X06-016 B03 04/05/07 35 X06-016 MV6 04/05/07 11 X06-016 B04 04/05/07 • 36 X06-016 08 04/05/07 12 X06-016 C01 04/05/07 37 X06-016 V3 04/05/07 13 X06-016 CO2 04/05/07 38 X06-016 V4 04/05/07 14 X06-016 CO3 04/05/07 39 X06-016 V8 04/05/07 15 X06-016 CA 04/05/07 40 X06-016 F01 04/05/07 16 X06-016 CJ 1 U 04/05/07 41 X06-016 F02 04/05/07 17 X06-016 CJ3 04/05/07 42 X06-016 F03 04/05/07 18 X06-016 CJ3U 04/05/07 43 X06-016 F04 04/05/07 19 X06-016 CJ5 04/05/07 44 X06-016 F05 04/05/07 20 X06-016 CJ5U 04/05/07 45 X06-016 F06 04/05/07 21 X06-016 EJ3 04/05/07 46 X06-016 F07 04/05/07 22 X06-016 EJ7 04/05/07 47 X06-016 F08 04/05/07 23 X06-016 EJ7U 04/05/07 ��;` _ C' 24 X06-016 FG1 04/05/07 ``���.'�� 7 • .. !�t!41 25 X06-016 FG2 04/05/07 f{1J ,• C E off; •,•.�� The truss drawing(s) refrenced above have been prepared by MiTek Ind stn s, Inc. �t7 ; No. 6 7 ,4 � .z under my direct supervision based on the parameters provided by UFP- t.Pie ce, FL. „�g Truss Design Engineer's Name: Tan, Seng-Chaff p D 11 D ED ��,• STA. E OF My license renewal date for the state of Florida is February 28,2009. :�•.•x- _NOTE: The seal on these drawings indicate acceptance of D R'lD •' �� professional engineering responsibility solely for the truss eng-Chaff Tan, FL Lic #46765 components shown. 345 Alhambra PL �4rltr IIUIN�� West Palm Beach, FL 33405 The suitability and use of this component for any particular APR 0 5 2001 MiTek Industries, Inc. building is the responsibility of the building designer, per FL Cert.#6634 ANSI/TPI-1 Chapter 2 W I G -Vera des���ijy a mgc�rs an 11r0 3 qNT 8 t}IVD VE E BEFORE qSE. 1 r to I fbrh�ebifd �tirb�6liJ�aSsl�JbhIIIflQ�6�@fi3r3vYfl�39161d�Br6lf9AtlluEillFfa�iih���A`rr�t0 jt�lOR.-.' 5 oMll? t �� �p� § � �r yf� % ii., {gomponent Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral suppo o ndlvidua we mem a ton y. ditiona emporary bracing to Insure stability during construction Is the responsibility of the erector. Addltional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 Donofrio Drive, Madison, WI 53719. M iTe k Symbols PLATE LOCATION AND ORIENTATION 13/4 * Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat, 0-�/e *For 4 x 2 orientation, locate Plates 0 - 1 /16" from outside edge of truss, i; *This symbol indicdtes the _ required directiori;of slots in connector plates:; * Plate location details avallable� in MiTek 20/20 software or upon request.t PLATE SIZE The first dimension is the width 4 x 4 perpendicular to slots. Second dimension is the length parallel to slots, LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output, Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) odcur, Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction, DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, .Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses, 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7, Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise, © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model 2029'8' X06-016 A01 COMIMON 4 1 Job Reference (optional) Univers".r6st Product, Inc. E359, Ft. Pierce, Fl. 34946, James L. Shoaf 6.500 s Feb 5 2007 MITek Industries, Inc. Thu Apr 05 07:21: Page 1 7-2-9 15-0-0 22-9-7 30-0-0 r 7-2-9 7-9-7 7-9-7 7-2-9 k ' Scale = 1:49. I - V 5x10 MT18H= lY 5.00 12 4 5x5 5x5 3 5 I 2 6 1 7 3.5 3x5 i 14 13 12 11 — 10 9 8 ' 30 11 3x8 = 3x4 11 0-0-0 0-0-0 ,1-0-0 7-2-9 15-0-0 22-9-7 29-0-0 p-0-0 1-0-0 6-2-9 7-9-7 7-9-7 6-2-9 1-0-0 Plate Offsets X 1:0-3-0,0-1-0, 3:0-2-8 0-3-0 , 5:0-2-8,0-3-0, :0-3-0,0-1$ , 8:0-3-0,0- 8 , 14:0-1-11,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdetl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.90 Vert(LL) -0.20 11-13 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.64 11-13 >516 180 MT18H 2441190 BCLL 10.0 Rep Stress Incr YES WB 0.15 Horz(TL) 9.08 8 n/a Na BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 135lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. T1 2 X 4 SYP No.1, T1 2 X 4 SYP No.1 BOT CHORD Rigid ceiling directly applied or 8-8-9 oc bracing. BOT CHORD 2 X 4 SYP SS WEBS 1 Row at midpt 3-11, 5-11 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 14=1350/0-8-0, 8=135010-8-0 Max Horz 14=104(LC 5) Max Upliftl4=-437(LC 5), 8=-037(LC 6) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=1836/432, 2-3=21001577, 3-0=16401465, 4-5=1640/465, 5-6=2100/578, 6-7=1836/432 BOT CHORD 1-14=-040M837, 13-14=-544/1837, 12-13=-544/1837, 11-12=544/1837, 10-11=-441/1837, 9-10=-441/1837, 8-9=-441/1837, 7-8=-441/1837 WEBS 3-13=-26/152, 3-11=-525/269, 4-11=97/632, 5-11=525/270, 5-9=26/152, 2-14=751/319, 6-8=7511319 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are MT20 plates unless otherwise indicated. 5) All plates are 3x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 437 lb uplift at joint 14 and 437 lb uplift at joint 8. LOAD CASE(S) Standard IN A WARNING - Very'y design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite 0300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTel Safety Informatlon available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. 1 Symbols PLATE LOCATION AND ORIENTATION 13/4 * Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 1Z O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside o edge of truss. _ *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO BEARING SBCCI Indicates location where bearings (supports) occur. Icons vary but reaction section Indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 96-31, 95-43, 96-20-1, 96-67, 84-32 4922, 5243, 5363, 3907 9667, 9730,9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O v 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber, 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection, 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14, Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® = k Job Truss Type Oty Ply Centex Homes, Model 2029'B' X06-016 F"Oulss SPECIAL 2 1 Job Reference o tional Univers76FOugst Product, Inc. E359, FL Pierce, Fl. 34946, James L. Shoaf 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07: 007 Page 1 7-2-9 1 5-0-0 1 9-2-4 23-4-8 26-9-7 30-0-0 J - —� s 7-2-9 7-9-7 4-2-4 4-2-4 3-4-15 3-2-9 Scale = 1:50. 6x8 = V 5.00 12 4 5 5x5 i W3 3x6 8 3x7 3 7 WS 3x6 2 8 W4 8 1 7x10 = 5x14 MT18H= 9 � Ia 4x6 4x6 r 4x6 = 3x7 = 17 16 15 _ 14 11 10 3x10 II 3x6 = 3x10 = 3x7 = 0-0-0 0-0-0 1-0-Q 7-2-9 15-0-0 19-2-4 23-4-8 26-4-6 29-0-0 30-0-0 1-0-0 6-2-9 7-9-7 4-24 4-24 2-1 1-14 2-7-10 1 -M Plate Offsets X, 1:0.3-10,0-1-0 , 3:0.2-8,0-3-4, :0-2-12,0-1-8, 8:0-2-0,0.1-8. 9:0-0-4,1-5-14 , 9:0-1-6,0-0-2. 1o:D-2-8,0-1.8 , 12:0-7-8,Ed e . 13:0-3-12 0-3-0 , 15:0-2-12.0-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) I/dell L/d PLATES GRIP TCLL 20.0 Plateslncrease 1.25 TC 0.66 Vert(L-) -0.23 12-13 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.92 Vert(TL) -9.68 12-13 >521 180 MT18H 244/190 BCLL 10.0 Rep Stress Incr YES WB 0.77 Horz(TL) 0.31 9 n1a n/a BCDL 10.0 Code FBC2004/TPI2D02 (Matrix) Weight: 173 Ito LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-5-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. Except: B4 2 X 4 SYP No.1 6-0-0 oc bracing: 5-13 WEBS 2 X 4 SYP No.2 10-0-0 oc bracing: 7-12 WEDGE WEBS 1 Raw at midpt 3-15 Right: 2 X 8 SYP SS SLIDER Left 2 X 6 SYP SS 3-5-11 REACTIONS (Ib/size) 1=132010-8.0, 9=1320/0-8-0 Max Horcl=104(LC 6) Max Upliftl=-375(LC 5), 9=-375(LC 6) FORCES (lb)- Maximum Compression/Maximum Tension TOP CHORD 1-2=2690/720, 2-3=2537/735, 3-4=-1841/614, 4-5=2951/859, 5-6=-3034/803, 6-7=3071/791, 7-8=-5287/1394, 8-9=27941779 BOT CHORD 1-17=703/2406, 16-17=703/2406, 15-16=70312406, 14-15=30/76, 13-14=0/44, 5-13=-273/166, 12-13=1240/5026, 11-12=5/103, 7-12=307/1332, 10-11=-83/310,9-10=-670/2498 WEBS 3-17=0/301,3-15=-W/389,4-15=90/115,13-15=327/1609,4-13=-509/1753,7-13=-2328/698,10-12=646/2404,8-12=-51812331, 8-10=1006/305 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are MT20 plates unless otherwise indicated. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 375 lb uplift at joint 1 and 375 lb uplift at joint 9. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component ° Safety Information W ion available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, I 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION 13/, *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O *For 4 x 2 orientation, locate plates 0 - 1/16" from outside o edge of truss. *This symbol Indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE. The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but EVI. reaction section Indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction, DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, Is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator, General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12, Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others, 15. Do not cut or alter truss member or plate without prior , 16. approval of a professional engineer. Install and load vertically unless indicated otherwise. ® Mi! MiTeka ME11 R © 2004 Mitek® Job Truss Truss Type Qty Ply Centex Homes, Model2029'B' X06-016 A02 HIP 2 1 Job Reference o lional Univers;ofoti@st Product, Inc. E359, Ft. Pierce, FI. 34946. James L. Shoat 6.500 s Feb 5 2007 MTek Industries, Inc. Thu Apr 05 074FAW007 Page 1 6-3-5 13-0-0 17-0-0 i 23-8-11 30-0-0 , 6-3-5 6-8-11 4-0-0 6-8-11 6-3-5 scale= 1:50. 4x6 = 46 = 4 5 5.00 12 3 6 W2 W2 2 7 1 8 , SaC ' I- 3x5 3x5 - 16 15 14 13 12 11 10 9 3x6 II 3x6 = 3x6 = 3x6 II 1-4-0 80-0 0- -00- 1-6-1-40 6-3-5 13-0-0 17-0-0 i 23-8-11 28-8-0 29;-9-0 1-0-0 4-11-5 6-8-11 4-0-0 6-8-11 4-11-5 0-4-0 04-0 1-0-0 Plate offsets 1:0-3.0.0-1-8 . 4:0-3-0,0-2-4. 5:0-3-0.0-2-4 , 8:D-3-0.0-1-8. 9:0-3.0.0.0-a . 16:a1-11.0.0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vde6 Idd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.86 Vert(LL) -0.27 13-15 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.74 Vert(TL) -0.67 13-15 >491 180 BCLL 10.0 Rep Stress Irxx YES WB 0.33 Horz(TL) 0.08 9 r✓a n/a BCDL 10.0 Code FBC2004rrP12002 (Matrix) Weight: 137lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 'Except TOP CHORD Structural wood sheathing directly applied or 2-2-1 oc pudins. T2 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 8-10.12 oc bracing. BOT CHORD 2 X 4 SYP SS WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 16=1350/048-0, 9=135010.8.0 Max Horz 16=-90(LC 6) Max Uplift16=-422(LC 5), 9=-422(LC 6) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=-1825/425, 2-3=-2075/552, 3-4=1743/461, 4-5=1557/463, 5-6=1743/461, 6-7=-2075/553, 7-0=-1825/426 BOT CHORD 1-16=-426/1817, 15-16=516/1817,14-15=-516/1817, 13-14=-516/1817, 12-13=-291/1557, 11-12=426/1817, 10-11=-42611817, 9-10=-026/1817, 8-9=.426/1817 WEBS 3-15=-66/109, 3-13=-402/241, 4-13=-39/318, rr12=39/318, 6-12=-4021242, 6-10=66/109, 2-16=713/280, 7-9=-713/280 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 422 lb uplift at joint 16 and 422 lb uplift at joint 9. LOAD CASE(S) Standard A WARNING - VerVy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component M e 0 k Safety InfoFinatlon available from Truss Plate Institute, 683 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/e *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1:,,National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, :Installing & Bracing of Metal Plate Connected Wood Trusses. 0 CC O U r.� Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 TEE=LOK�� AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1, 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty Ply Centex Homes, Model 2029'B' X06-016 A03 HIP 2 1 Job Reference (optional) Universq&�qsl Product, Inc. E359, Ft. Pierce, FI. 34946. James L. Shoaf 6.500 s Feb 5 2007 MTek Industries, Inc. Thu Apr 05 07: 007 Page 1 L 5-6-4 11-0-0 19-0-0 24-5-12 30-0-0 5-6-4 5-5-12 8-0-0 5-5-12 5-6-4 Scale = 1:50. lox10 c Sx7 zz 4 5 5.00 12 3x4 >3x4W3 2 7 1 8 ]g 3x5 3x5 G 14. 13 12 11 10 9 3x4 = 3x8 = 14-0 0-0-0 0- -0 1-00--0 11-0-0 19-M 28-8-0 1-0-0 9-8-0 8-0-0 9-8-0 04-0 0-4-0 1-0-0 Plate Offsets KYY [11:0-3-0,01A. 4:0-4-5,E e , 5:0-34.0-2.8 , 8:0.3-00-1-8, 9:0-3-00-M , 14:0-1-11,0-1-4 LOADING (psQ SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.71 Vert(LL) -0.23 11-12 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.87 Vert(TL) -0.57 11-12 >575 180 BCLL 10.0 Rep Stress Incr YES WS 0.09 Horz(TL) 0',08 9 n/a Na BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 137 Ito LUMBER BRACING TOP CHORD 2 X 4 SYP SS *Except' TOP CHORD Structural wood sheathing directly applied or 3-4-13 00 pudins. T2 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 9-0-13 oc bracing. BOT CHORD 2 X 4 SYP No.1 WEBS 1 Row at midpt 4-11 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 14=1350/0-8-0, 9=1350/0-8.0 Max Horz 14=-76(LC 6) Max Upliftl4=-004(LC 5), 9=-404(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1714/398, 2-3=-2059/556, 3-4=-1903/536, 4-5=1736/538, 5-6=1903/536, 6-7=-2059/556, 7-8=1714/398 BOT CHORD 1-14=-035/1774, 13-14=488/1774, 12-13=-088/1774, 11-12=387/1736, 10-11=-435/1774, 9-10=•435/1774, 8-9=-435/1774 WEBS 3-12—M170, 4-12=0/315, 4-11=144/144, 5-11=-1/315, 6-11=-681171, 2-14=9631414, 7-9=963/414 NOTES 1) Unbalanced roof live loads have been considered for this design. .2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x6 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 404 lb uplift at joint 14 and 404 lb uplift at joint 9. LOAD CASE(S) Standard LA WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, r_0 Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Appllcabllity of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSM9 and BCSI1 Building Component M iT k° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat, U -�/74, *For 4 x 2 orientation, locate plates 0 -1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on Inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all pC other interested parties. 4. Cut members to bear tightly against each other. 0- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MITek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9, Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated b symbol shown and/or Y Y BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is Installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur, Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeke DSB-89: Design Standard for Bracing. ' BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Job Truss Truss Type Qty Ply Centex Homes, Model 2029'8' X06-016 A05 HIP 2 1 Job Reference (optional) UniversabE"t Product. -Inc. E359, Ft. Pierce, Fl. 34946, James L. Shoaf 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:Y844Lt007 Page 1 4-5-2 9-0-0 15-0-0 21-0-0 25-6-14 30-0-0 I , � 4-5-2 4-0-14 6-0-0 6-0-0 4-6-14 4-5-2 " scale = 1:50. I 5x8 ti I 5x8 zz 4 5 6 j 5.00 F12 i 3 W2 V W2 7 3 w 8 i 2 1 9 o g1 Ig 3x6 — 3x6 = 16 15 14 13 12 11 10 3x8 II' 3x6 = 3x8 = Us = 3x8 II -0 1-4-0 d O 1-�tt 9-0-0 15-0-0 21-0-0 28-8-0 2�-Q-0 1-0-0 7-8-0 6-0-0 6-0-0 7-8-0 04-0 0-4-0 1-0-0 Plate Offsets X 4:0-3-0.0-2-8 , 6:0-M 0-2-8 , 10:0-0 0 0-G , 16:0-4-12,0-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.71 Vert(LL) -0.17 13-15 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.89 Vert(TL) -0.46 13-15 >714 180 BCLL 10.0 Rep Stress Incr YES WB 0.14 Horz(TL) 0.09 10 n/a We BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 143lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS *Except* TOP CHORD Structural wood sheathing directly applied or 3-6-3 oc pudins. T2 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 9-2-0 oc tracing. BOT CHORD 2 X 4 SYP No.2 WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 16=1350/0.8-0, 10=135010-8-0 Max Horz 16=-62(LC 6) Max Upliftl6=396(LC 3), 10=396(LC 4) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=1569/407, 23=1944/560, 3.4=2001/594, 45=-2260/738, 5-6=-2260f/38, 6-7=2001/594, 7-8=1944/560, 8-9=1569/407 BOT CHORD 1-16=-437/1644, 15-16=-440/1644, 14-15=-460/1833, 13-14=-060/1833, 12-13=-058/1833, 11-12=458/1833, 10-11=-438/1644, 9-10=-038/1644 WEBS 3-15=39/315, 4-15=17/172, 4-13=-190/594, 5-13=-403/213, 6.13=-190/594, 6-11=17/172, 7-11= 39/315, 2-16=1041/384, 8-10=1041/384 NOTES 1) Unbalanced roof live loads have been considered for this design. .2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 396 lb uplift atjoint 16 and 396 lb uplift atjoint 10. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of IndividUal web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component M iTe k® Safety Infofmation available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 0-1/0and securely seat. T74��For 4 x 2 orientation, locate plates 0 -1/16" from outside edge of truss. _ . *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI I:. National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSII : Building Component Safety Information, 'Guide to Good Practice for Handling, Installing & Bracing of Metal Plate .Connected Wood Trusses. 0 O U a O R Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII . 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design, 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16, Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty Ply Centex Homes, Model 2029'B' X06-016 A06 HIP 1 1 Job Reference o Gonal Universtfiygst Product, Inc.-E359, Ft. Pierce, Fl. 34946, James L. Shoaf 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21: -Page 1 4-5-15 7-0-0 124-9 17-7-7 23-0-0 25-6-1 30-0-0 } 4-5-15 2-6-1 5-4-9 5-2-13 54-9 2-0-1 4-5-15 ' Scale= 1:49.4 6x10 = 6x10 = 5.00 12 4 16 17 5 18 19 20 6 21 22 7 iz 3 8 W7 I VZ W1 Kt w1 1 V2 9 2 3 W 1 10 PEE -------------------I$ 7x12 = 15 23 24 14 25 26 13 27 12 28 29 11 4x14 = 5x10 MT18H i 300 = 5x10 MT18H= 3x6 = 5x10 MT18H- 0-0-0 0-0-0 P-0-0, 7-0-0 124-9 17-7-7 23-0-0 29-0-0 30-0-Q 1-0-0 6-0-0 5-4-9 5-2-13 5-4-9 6-0-0 1-0-0 Plate Offsets X 1:0-0-1,0-3-14 , 4:0.3-00-0-0 , :0-3-00.4-0 , 10:0-5-3,0-2-0 , 12:0-2-0.0-1-8 , 14:0.4-8.0-1.8 LOADING (pst) SPACING 2-M CSI DEFL in (loc) Ildetl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.59 Vert(LL) 0.27 12-14 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.57 Vert(TL) -0.71 12-14 >492 180 MT18H . 244/190 BCLL 10.0 Rep Stress Incr NO WB 0.38 Horz(TL) 0.17 10 n/a n/a BCDL 10.0 Code FBC2004RPI2002 (Matrix) Weight: 1831b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-3.12 oc pudins. T2 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 5-&2 oc bracing. BOT CHORD 2 X 6 SYP SS WEBS 2 X 4 SYP No.2 SLIDER Left 2 X 4 SYP No.2 1-9-5, Right 2 X 4 SYP No.2 1-9-5 REACTIONS (lb/size) 1=2514/0-8-0, 10=2514/0-8-0 Max Horz 1=47(LC 5) Max Uplift1=-829(LC 5), 10=-829(LC 3) FORCES (lb) - Maximum Compressiorl/Maximum Tension TOP CHORD 1-2=5739/1928, 2-3=5636/1939, 3-0=-5671/1961, 4-16=7022(2510, 16-17=7023/2510, 5-17=-7025/2510, 5-18=7023/2509, 18-19=7023/2509, 19-20=7023/2509, 6-20=7023/2509, 6-21=7034/2519, 21-22=7032/2519, 7-22=-7031/2519, 7-8=-5671/1974, 8-9=5638/1952, 9-10=5740/1941 BOT CHORD 1-15=-1737/5192, 15-23=-1756/5284, 23-24=1756/5284, 14-24=1756/5284, 14-25=-2427/7032, 25-26=242717032, 13-26=2427/7032, 13-27=2427/7032, 12-27=-2427/7032, 12-28=-1766/5284, 28-29=1766/5284, 11-29=1766/5284, 10-11=1745/5194 WEBS 3-15=31/224, 4-15=62/543, 4-14=751/2034, 5-14=-696137T,'&14=73/33, 6-12=719/378, 7-12=74812026, 7-11= 62/542, 8-11=32/227 - NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. - 6) All plates are MT20 plates unless otherwise indicated. 7) All plates are 3x4 MT20 unless otherwise indicated. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 829 lb uplift at joint 1 and 829 lb uplift at joint 10. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 313 lb down and 192 lb up at 7-0-0, 104 lb down and 75 , Ib up at 9-0-12, 104 Ib down and 75 Ib up at 11-0-12. 104 lb down and 75Ib up at 13-0-12, 104 lb down and 75 lb up at 15-0-12, 104 Ib down and 75Ib up at 16-11-4, 104 lb down and 75Ib up at 18-114, and 104 lb down and 75 lb up at 20-114, and 353 lb down and 192lb up at 23-0-0 on top chord, and 363 lb down and 75 lb up at 7-0-0, 64 lb down at 9-0-12, 64 lb down at 11-0-12, 64 lb down at -13-0-12. 64 lb down at 15-0-12, 64 lb down at 16-11.4, 64 Ito down at 18-11-4, and 64 lb down at 20-114, and 363 lb down and 75 lb up at 22-114 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 ' Uniform Loads (plf) Vert: 1-4=-70, 4-7=-70, 7-10=-70, 1-10=-20 Concentrated Loads (lb) e WARNING - Verify esign parameters and READ NO S ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component kO Safety Infofrmation available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. iTe Symbols PLATE LOCATION AND ORIENTATION 13/a * Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. -1/16" 0 O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside o edge of truss. R *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety- Information, Guide to Good Practice for, Handling, Installing & Bracing of Metal Plate .Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBEREDAETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. 0 U 4. Cut members to bear tightly against each other. d 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 195v. at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber, 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements, 11, Lumber used shall be of the species and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. MiTek° © 2004 Mitek® Job Truss Type Oty PlyTJob tex Homes, Model 2029'B'Job A07 THuPss 1X06 Reference (optional) UniverstFut®st Product, Inc. E359,-Ft: Pierce, FI. 34946, James L. Shoat 6.500 s Feb 5 9007 MTek Industries. Inc. Thu Apr 05 07:21: Page 1- 4-5-15 7-0-0 124-9 17-7-7 23-0-0 25-6-1 30-0-0 4-5-15 2-6-1 5-4-9 5-2-1 3 54-9 2-6-1 4-5-15 Scale = 1:49. 4 6x10 = 6x10 = 5.00 12 4 16 17 5 18 19 20 6 21 7 3 8 W1 I vz W1 W1 I vZ9 2 3 W 1 10 jg 7x12 = 15 22 23 14 24 25 13 26 12 27 28 29 11 30 31 404 = 500 MT18H i 3x10 = 5x10 MT18H= 3x6 = 3x12 0-0-0 0-0-0 ,1-0-0, 7-M i 12-4-9 i 17-7-7 23-0-0 29-0-0 30-04 1-0-0 .6-0-0 54-9 5-2-13 54-9 6-0-0 1-0-0 Plate Offsets X, 1:0.0-0,0-3-13 , 4:0-3-0,0-3-12 , :0.2-12,0-3-12 , 10:0-4-3,0-2-0, 10:0-1-1,0-5-0, 12:0-1-12,0-1-8 , 14:0-0-4,0-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Vd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.57 Vert(LL) 0.26 12-14 >999 360 MT20 244/190 TCDL 15.0 Lumber increase 1.25 BC 0.55 Vert(TL) .-0.68 12-14 >515 180 MT18H 244/190 BCLL 10.0 Rep Stresslncr NO WB 0.40 Horz(TL) 0.16 10 n/a n/a BCDL 10.0 Code FBC2004rrP12002 (Matrix) Weight: 183 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 *Except* TOP CHORD Structural woad sheathing directly applied or 2-4-7 oc pudins. T2 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 5-7-2 oc bracing. BOT CHORD 2 X 6 SYP SS WEBS 2 X 4 SYP No.2 SLIDER Left 2 X 4 SYP No.2 1-9-4, Right 2 X 4 SYP No.2 1-9-4 REACTIONS (Iblsize) 1=2452/0-8-0, 10=2377/0-8-0 Max Horz1=-47(LC 6) Max Upliftl =-801 (LC 4). 10=783(LC 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-5577/1873,2-3=5486/1884,3-0=5513/1904,4-16=-676812419,16-17=-6769/2419,5-17=-6771/2419,5-18=-6769/2418, 18-19-6769/2418, 19-20=-6769/2418, 6-20=-6769/2418,6-21=-6642/2374,7-21=-6640/2374,7-8=5141/1781,8-9=5179/1783, 9-10=5260/1775 BOT CHORD 1-15=-1685/5055, 15-22=1703/5138, 22-23=1703/5138, 14-23=1703/5138, 14-24=2281/6640, 24-25=-2281/6640, 13-25=-2281/6640, 13-26=-2281/6640, 12-26=-2281/6640, 12-27=-1589/4796, 27-28=-1 589/4796,28-29=1589/4796, 11-29=-1589/4796,11-30=-1598/4781, 30-31=1598/4781, 10-31=-1598/4781 1-1 WEBS 3-15=26/214, 4-16=-64/545, 4-14=708/1912, 5-14=-7051383, 6-14=106/209, 6-12=794/408, 7-12=-784/2153, 7-11=-202/642, 8-11=26/124 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. - - 6) All plates are 3x4 MT20 unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 801 Ito uplift at joint 1 and 783 Ito uplift at joint 10. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 313 lb down and 192 lb up at 7-0-0, 104 lb down and 75 lb up at 9-1-1. 104 lb down and 75 lb up at 11-1-1, 104 lb down and 75 lb up at 13-1-1, 104 lb down and 75 lb up at 15-1-1, and 104 lb down and 75 lb up at 17-1-1, and 138 lb down and 100lb up at 18-3-4 on top chord, and 363lb down and 75 lb up at 7-0-0, 64 lb down at 9-1-1, 64 lb down at 11-1-1, 64 lb down at 13-1-1, 64 Ito down at 15-1-1. 64 lb down at 17-1-1, 79 lb down at 18-3-4, 121 lb down and 26 lb up at 20-3-4, 56 lb down and 17lb up at 22-3-4, and 184 lb down and 70 lb up at 24-3-4, and 235 lb down and 103 lb up at 24-11-4 on bottom chord. The desigNselection of such connection device(s) is . the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=70, 4-7=70. 7-10=-70, 1-10=-20 Concentrated Loads (lb) Vert:4=-313(F) 15=-363(F) 16=-104(F) 17=-104(F) 18=-104(F) 19=-104(F) 20=-104(F) 21=-138(F) 22=-44(F) 23=44(F)24=44(F)25=-44(F) A WARNING - Ver! N design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, r.O Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of Individual web members only.Additional temporary bracing to Insure stablllty during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrlcafion, qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iT k° Safety Infofmatlon available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 * Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses, 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. BEARING Indicates location where bearings 14. Connections not shown are the responsibility of others. �Su (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior Lip reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise, Industry Standards: ANSI/TPI1:.National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek® DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal. Plate © 2004 Mitek® `Connected Wood Trusses. Job uss TypeOty Ply Centex Homes, Model 2029'B' TTrussJc� X06-016OMMON 5 1 Job Reference (optional) Universal F(ygStrroduct, Inc. E359, FL Pierce; FI. 34946. James L. Shoaf 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:46 2 ge 1 5-11-14 11-9-0 17-6-4 21-7-0 5-11-14 5-9-2 5-9-4 4-0-11 s ca e = 1:36.1 4x6 = 4 5.00 12 6x8 3 W W1 5 3x5 2- 3x6 II 6 2 t I� Ev9 11 8 7 3x12 II 3x6 = 1-4-0 0-0-0 r1-0 � 0-0 7-11-2 15 6-15 21-7-0 1-0-0 6-7-2 7-7-13 6-0-1 0-4-0 Plate Offsets X 1:0.3-0,0-1-8, 2:0-1-11,0-0-4 , 5:04-0,0-24 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.26 TC 1.00 Vert(LL) -0.09 7-9 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.31 7-9 >795 180 BCLL 10.0 Rep Stress Incr NO WB 0.11 Horz(TL) 0.04 6 Na nla BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight. 109 Ito LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 9-64 oc bracing. B1 2 X 4 SYP SS WEBS 2X4SYP No.2 SLIDER Right 2 X 8 SYP SS 4-7-13 REACTIONS (lb/size) 6=97210-3-8, 10=1314/0-8-0 Max Horz10=81(LC 5) Max UpIM6=271(LC 6), 10=-423(LC 5) FORCES (lb) - Maximum Compresslon/Maximum Tension TOP CHORD 1-2=1575/376, 2-3=-1787/500, 3-4=-1587/464, 4-5=-1443/434, 5-6=-1596/451 BOT CHORD 1-10=378/1557, 9-10=-460/1557, 9-11=-238/1093, 8-11=238/1093, 7.8=238/1093, 6-7=-332/1324 WEBS 3-9=249/192, 4-9=163/586, 4-7=-112/330, 5-7=-154/167, 2-10=620/277 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category -II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 3x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 271 Ito uplift at joint 6 and 423 lb uplift at joint 10. LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) - — - - Vert: 1-4=70, 4-6=70, 1-10=20. 10-11=65, 6-11=20 A WARNING - Verify design parameters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component Well° Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. m *For 4 x 2 orientation, locate O v plates 0 - 1/16" from outside o- edge of truss. *This symbol indicates the _ required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 TIE&LOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is Installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16, Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty Ply Centex Homes, Model 2029'B' X06-016 B02 HIP 1 1 Job Reference (optional) Universal F( ufgProduct, Inc. E359, Ft. Pierce, FI. 34946, James L. Shoaf 6.500 s Feb 5 2007 MSTek Industries, Inc." Thu Apr 05 07:21 AT QdWPage 1 6-10-1 11-0-0 12-6-0 , 16-7-15 21-7-0 i 6-10-1 4-1-15 1-6-0 4-1-15 4-11-1 ' Scale = 1:36. 46 = 46 = 4 6 6.00 F12 6x8 3 6 3x5 3x5 2 w 7 2 1 I`I 10 9 8 5x12 11 3x6 11 3x6 = 1-4-0 0-0 0-0-0 1-0 11-0-0 , 12-0-0 , 21-7-0 1-0-0 9-8-0 1-6-0 9-1-0 0-4-0 Plate Offsets X, 3:0.0-8 0-0-6:04-00-2-4, :0-3-4,0-1-11 , 11:0.1-11,0-0-8 LOADING (psf) SPACING 2-0.0 CS! DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.86 Vert(LL) -0.15 10-11 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.90 Vert(TL) -0.35 10-11 >686 180 BCLL 10.0 Rep Stress Incr YES WB 0.12 Horz(TL) 0.04 7 rJa Na BCDL 10.0 Code FBC20041TP12002 (Matrix) Weight 113 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-1-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. WEBS 2 X 4 SYP No.2 SLIDER Right 2 X 8 SYP SS 5-9-7 REACTIONS (lb/size) 7=90710-3-8.11=103510-8-0 Max Horz 11=76(LC 5) Max Uplift7=-248(LC 6). 11=344(LC 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-1211/245, 2-3=-1436/404, 3-4=1135/308, 4-5=-1019/310, 5-6=11581312, 6-7=1414/394 BOT CHORD 1-11=-278/1228, 10-11=-354/1228, 9-10=178/1019, 8-9=-272/1183, 7-8=272/1183 WEBS 3-10=299/209, 4-1 0=-1 0/244, 5-9=74/275, 6-9=-255/203, 2-11=-664/357 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02;130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load n onconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 248lb uplift at joint 7 and 344 lb uplift at joint 11. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an individual building component, Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the bullding designer. For general guidance regarding fabrication, quallt control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTek® Safe Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate 3: plates 0 - 1 /16" from outside a. edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on Inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all m other interested parties. 0 U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16, Install and load vertically unless indicated otherwise. © 2004 MiteP Job Truss Type Oty Ply Centex Homes, Model 2029'B'X06-016 B03 THlul 1 1 Job Reference (optional) Universal bo" Product, Inc. E359, Ft. P erce, Fl. 34946, James L. Shoaf 6.500 s Feb 5 2007 MTek Industries, Inc. Thu Apr 05 0 : - 2007 Pagel 4-5-2 9-0-0 14-6-0 19-0-14 23-6-0 4-5-2 4-6-14 5-6-0 4-6-14 4-5-2 * Scale = 1:39. 5x8 = 46 = 4 5 5.00 12 3 W1 6 3 W 2 7 . 1 8 132 3x5 — 3x5 = 11 10 3x6 II 502 = 3x6 II 1 4-0 0-020-6-0 1-0450-o M-0 14-6-0 22-2-0 22-1-0 1-0-0 7-8-0 5-6-0 7-8-0 0-4-0 0-4-0 1-" Plate Offsets X 4:0.5-0,0-2-4 , 5:0-3-0,0-2-4 , 9:0-3-00-0 8 , 10:0-3-4,0-3-0 , 12:0-1-11.0-0-12 LOADING (psf) SPACING 2-0.0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.96 Vert(LL) -0.12 10-11 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.30 10-11 >840 180 BCLL 10.0 Rep Stress Ina YES WB 0.07 Horz(TL) 0.05 9 n/a n/a BC -DI- 10.0 Code FBC2004/TP12002 (Matra) Weight: 108 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (Ib/size) 12=1058/0-8-0, 9=1058/0-6-0 Max Horz 12=-62(LC 6) Max Upliftl2=-332(LC 5), 9=-332(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=1170/270, 2-3=-1439/389, 3-4=1360/378, 4-5=-1234/382, 5-6=1361/378, 6-7=1439/389, 7-8=1170/271 BOT CHORD 1-12=292/1215, 11-12=339/1215, 10-11=-259/1234, 9-10=-292/1215, 8-9=-292/1215 WEBS 3-11=6/140, 4-11=0/213, 4-10=-107/108, 5-10=1/213, 6-10=6/140, 2-12=772/328, 7-9=-773/327 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 332 lb uplift at joint 12 and 332 lb uplift at joint 9. LOAD CASE(S) Standard ® WARNING - Verify design parameters and READ NOTES ON TRIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of ind(vidual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 cc O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside o edge of truss. O *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20120 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. r' LATERALBRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING, Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1:.National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89:' Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Conniected Wood Trusses, Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior 16. approval of a professional engineer. Install and load vertically unless indicated otherwise. MiTek° © 2004 MiteV Job Truss Truss Type Oty Ply tex Homes, Model 2029'B' X06-016 B04 HIP 1 Tjo Reference Ia 8onal Universal 6p" Product; Inc. E359, Ft. Pierce, FI. 34946. James L. Shoaf 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21002 7 Page 1 4-7-4 7-" 11-9-0 16-0-0 18-10-12 23-6-0 4-7-4 2-4-12 4-9-0 4-9-0 2-4-12 4-7 4 Scale = 1:38. 5x8 = 5x8 = 4 14 15 5 16 17 6 5.00 12 3 7 2 W 2 8 3 1 9 ''aa rd 5x10 t:;- 5x10 5x8 = 13 18 19 12 20 11 21 10 5x8 = 3x8 = 3x10 MT18H= 0-0-0 0-0-0 ,1-0-0 , 7-0-0 11-9-0 16-" 22-6-0 123-6-0, 1-0-0 6-0-0 4-9-0 4-9-0 6-0-0 1-0-0 Plate Offsets X, 1:0-3-2 0-2.8 4:0-5-4,0-2-4 6:0-5-4,0-2-0, 9:0-3-2,0-2-8 LOADING (psf) SPACING 2.0-0 CSI DEFL in (too) Vdefl Vd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.47 Vert(LL) 0.15 12 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.72 Vert(TL) -0.40 10-12 >684 180 MT18H 244/190 BCLL 10.0 Rep Stress Inor NO WB 0.16 Horz(TL) 0.14 9 Na n/a BCDL 10.0 Code FBC2004frP12002 (Matrix) Weight: 117lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural woad sheathing directly applied or 2-9-15 oc puriins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-10-8 oc bracing. WEBS 2 X 4 SYP No.2 SLIDER Left 2 X 6 SYP SS 2-0-11. Right 2 X 6 SYP SS 2-0.11 REACTIONS (Ibdsize) 1=1759/050, 9=1759/0-8-0 Max Horz1=-49(LC 6) Max Upliftl=-597(LC 5), 9=587(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=3749/1281,2-3=-3649/1289,3-4=3637/1268,4-14=-403811465,14-15=-4038/1465,5-15=-4038/1465,5-16=-4037/1465,16-17=4038/1465,6-17=-4038/1465, 6.7=3637/1277, 7-8=3649/1268, 8-9=-3749/1263 BOT CHORD 1-13=1167/3358, 13-18=1118/3376, 18-19=-111813376, 12-19=1118/3376, 12-20=1111/3376, 11-20=1111/3376, 11-21=1111/3376, 10-21=1111/3376, 9-10=1108/3358 WEBS 3-13=14/149, 4-13=-67/483, 4-12=313/856, 5-12=621/347, 6-12=3021834, 6-10=68/483, 7-10=15/153 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20fl; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 3x4 MT20 unless otherwise indicated. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 597 lb uplift at joint 1 and 587 lb uplift at joint 9. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)187 lb down and 131 lb up at 7-0-0, 104 lb down and 75 lb up at 9-0-12, 104 lb down and 75 lb up at 11.0-12, 104 lb down and 75 lb up at 12-54, and 104 lb down and 75 lb up at 14-5-4, and 227 lb down and 131 lb up at 16-6-0 on top chord, and 248 lb down and 66lb up at 7-0.0. 64 lb down at 9-0-12, 64 lb down at 11-0-12, 64 lb down at 12-5-4, and 64 lb down at 14-5-4, and 248 lb down and 66 lb up at 16-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-70, 4-6=70, 6-9=-70, 1-9=20 Concentrated Loads (lb) Vert: 4=-187(B) 6=-187(B)13=248(B)10=-248(B)14=104(B) 15=104(B) 16=104(B) 17=-104(B) 18=-44(B)19=-04(B) 20=-44(B) 21=44(B) A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, clualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Well° Safety Infc6nation available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/q *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate 0 plates 0 - 1/16" from outside a_ edge of truss. 0 *This symbol indicates the _ required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL.BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, 'Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730,.9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteO Jab ss us Trs Type Oty B' Ply Centex Homes, Model 2029'X06-016 0] ;Tru COMMON 1 1 U Job Reference (optional) Universal Forest Product; Inc. E359, FL Pierce, Fl. 34946, James L. Shoaf-- 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:48 20070EM 1 4-7-0 8-2-0 4-7-0 3-7-0 r ` Scale = 1:13. 4x6 = 2 5.00 12 3 T2 W1 T1 2 4 1 i d, d H, 131 4x6 C 5 0- 3x6 If 3x7 11 0-0-0 1-0-0 4-7-0 8-2-0 r 1-0-0 3-7-0 3-7-0 Plate Offsets l:0-1-4 0-11-14 t0-1-14 0.0-2 , 4:0-3-12,0-3-9 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.32 Vert(LL) 0.02 1-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC . 0.41 Vert(TL) -0.03 1-5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.04 Horz(TL) 0.01 4 n/a Na BCDL 10.0 Code FBC2004frP12002 (Matrix) Weight: 34 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEBS 2X4SYP No.2 WEDGE Left: 2 X 4 SYP No.2 SLIDER Right 2 X 6 SYP SS 1-11-0 REACTIONS (lb/size) 4=361/0-8-0.1=361/0-3-8 Max Horz1=32(LC 6) Max Uplift4=-238(LC 6), 1=-245(LC 5) FORCES (lb) - Maximum CompressiowMaximum Tension TOP CHORD 1-2=-471/299, 2-0=418/319, 3-0=-493/314 BOT CHORD 1-5=245/386, 4-5=245/386 WEBS 2-5=145/198 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.0psf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 3x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 238 Ib uplift at joint 4 and 245 lb uplift at joint 1. LOAD CASE(S) Standard _ e WARNING - Ver(& design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, qualif�'control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety Infoimation available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/q *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. *For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE. The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output, Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Sidndards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction, DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, .Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, 0 cc O U a O Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all fr other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at ]Off. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mite[& Job Job Truss Type Oty Fly Cenlex Homes, Model 2029'B' Trou2ss COMMON 3 1 Job Reference (optional) 0-0-0 Universal Forest Produc01U:C 359, FL Pierce, Fl. 34946, James L. Shoaf 6.500 s Feb 5 2007 MTek Industries, Inc. Thu Apr 05 07:21.49 2007 Page 1 4-7-0 9-2-0 4-7-0 4-7-0 Scale= 1:14. 46 = 3 5.00 12 W1 T1 T1 4 2 5 1 o � B, 1, 7 3x6 11 3x6 110-0-0 0-0-0 1-0-0 1-4-0, 7-10-0 18-2-01 9-2-0 1-0-0 04-0 6-" 04-0 1-0-0 PlateOffsets X 6:0-3-00-1-48:0-1-110-0-0 LOADING (psf) SPACING 2-0.0 CSI DEFL in (loc) Vdefl Idd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.20 Vert(LL) -0.01 7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.19 Vert(TL) -0.02 7 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL.) 0.00 . 6 Na Na BCDL 10.0 Code FBC2004rFP12002 (Matrix) Weight: 32 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEBS 2X4SYP No.2 REACTIONS (lb/size) 8=412/0-8-0, 6=413/0-8-0 Max Horz8=32(LC 6) Max Uplfft8=289(1_C 5), 6=-289(LC 6) FORCES (Ib) - Maximum CompressionfMaximum Tension TOP CHORD 1-2=188/133, 2-3=2601179, 3-4=260/179, 4-5=-188/133 BOT CHORD 1-8=121/189, 7-8=-121/189, 6-7=121/189, 5.6=-121/189 WEBS 3-7=-64f75, 2-8=-2681166, 4-0=-268/166 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 3x4 MT20 unless otherwise indicated. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 289 lb uplift at joint 8 and 289 lb uplift at joint 6. LOAD CASE(S) Standard i e WARNING - Verify design pammeters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Mel Symbols . PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 -1/ie' from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots, Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1; National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 Ir O U Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1, Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall. be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitel& Job Truss Truss Type Oty Ply Centex Homes, Model 2029'9 X06-016 CO3 HIP 1 1 Job Reference (optional) 0-0-0 Universal Forest Produr0-loc0E359, Ft. Pierce, Fl. 34946. James L. Shoaf _ 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:49 2007 Page 1 3-0-0 6-2-0 9-2-0 3-0-0 3-2-0 3-0-0 Scale= 1:15.1 I I 4x6 = 46 = .I 2 7 3 1 ! 5.00 12 T2 W1 W1 T1 T1 4 j �W2 1 HIVI B1 lg 6 B 5 3x6 II 3x8 II 0-0-0 0-0-0 1-0-0 1,1-12 3-M 6-2-0 7-10-0 18-2-0, 9-2-0 , ! 1-0-0 0-1-12 1-10-4 3-2-0 1-8-0 0-4-0 1-0-0 Plate Offsets X, 1:0-1-14,0-0-2 , 1:0-1-4,0-11-14 , 4:0-1-14.0-04:0-M,132 LOADING (psf) SPACING 2-0.0 CSI DEFL in (too) Ildeft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.31 Vert(L-) 0.02 6 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.38 Vert(TL) -0.03 6 ' >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.02 HoaJL) 0.01 4 n 1a Na BCDL 10.0 Code FBC2004rTP12002 (Matra) Weigtt.. 35 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2 X 4 SYP No'2 BOT CHORD Rigid ceiling directly applied or 8-9-15 oc tracing. WEBS 2 X 4 SYP No.2 WEDGE Left: 2 X 4 SYP No.2, Right: 2 X 6 SYP SS REACTIONS (lb/size) 1=36403-8, 4=36310-8-0 Max Horz1=-21(LC 6) Max Uplift1=322(LC 5), 4=-323(LC 6) FORCES (lb) - Maximum CompressionfMaximum Tension TOP CHORD 1-2=-637/566, 2-7=-551/548, 3.7=551/548, 3-4=-640/573 BOT CHORD 1-6=500/546, 6-8=512/551, 5-8=512/551, 4-5=-497/545 WEBS 2-6=-120/118, 3-5=130/125 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60. 3) Provide adequate drainage to prevent water ponding. 4) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 322 lb uplift at joint 1 and 323 lb uplift at joint 4. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)1 Ito down and 41 lb up at 3-", and 3lb down and 27 lb up at 4-7-0, and 1 lb down and 41 lb up at 6-2-0 on top chord, and 10lb down and 27 Ito up at_ 3-0-0, and 0 lb down and 18 lb up at 4-7-0, and 10lb down and 27 Ib up at 6-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=70, 23=-70, 3-4=70. 14=20 Concentrated Loads (lb) Vert: 2=1(F) 3=-1(F) 6=7(F) 5=7(F) 7=27(F) 8=15(F) A WARNING - Vertjy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iT k® Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the _ . required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL.BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but 1_i�re reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89:' Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate .Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A ILOK ■C AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty Ply Homes. Model2029'B' X06-016 CA MONO TRUSS 6 1 7JnhReference o tfonal Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L. Shoaf - 2 6.�90"b 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:49 2007 Page 1 1-0-0 1-0-0 , s.00 1z Scale = 1:4. 1 SIMPSON T1 MTS 16 3A = 3 0-4-10 0-0-0 1-0-0 1-0-0 Plate Offsets 1:0-0-00-0-0 LOADING (psf) SPACING 2-0-0 Csl DEFL in (loc) Udell L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) -0.00 1 nlr 180 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) -0.00 1 Nr 90 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a We BCDL 10.0 Code FBC2004/rP12002 (Matra) Weight 3 lb - LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 64W oc bracing. REACTIONS (lb/size) 3=10/Mechanical, 2=79/Mechanical Max Horz3=98(LC 1). 2=98(LC 1) Max Upli13=-14(LC 3). 2=-50(LC 5) Max Grav3=20(LC 2), 2=79(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-80/119 BOT CHORD 1-3=98/82 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girders) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3 and 50lb uplift at joint 2. - 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard a WARNING - Ver(& design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building deslgner - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Indiyidudl web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCS11 Building Component ° Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. We Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 -'/ie * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur, Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 Cc O 2 U a_ O R Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95A3, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 TEE10- K AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury I . Additional stability bracing for truss system, e.g, diagonal or X-bracing, is always required. See BCSII I. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane atjoint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1, 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, If no ceiling Is Installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise. © 2004 Mitee Job Truss Truss Type aY Ply Homes, Model 2029'B' X06-016 CJt U MONO TRUSS 8 1 Job Reference Io 6ona1 Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L. Shoaf - 2 6.590"b 5 2007 tuiTek Industries, Inc. Thu Apr 05 07:21:49 2007 Page 1 1-0-0 1-0-0 $ 5.00 ,z Scale =1:4. , SIMPSON MTS 16 jTI 3x4 = 3 0-4-10 0-0-0 1-0-0 1-0-0 Plate Offsets X, 1:0-0-0 0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) -0.00 1 n/r 180 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.02 Vert(TL) -0.00 1 Nr 90 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0; 00 n/a n/a BCDL 10.0 Cade FBC2004/TPI2002 (Matrix) Weight: 3 Ito LUMBER BRACING TOP CHORD 2 X 4 SYP N0.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS (Ib/siize) 3=10/Mechanical, 2=79/Mechanical Max Horz3=-98(LC 1). 2=98(LC 1) Max Uplift3=14(LC 3), 2=50(1-C 5) Max Grav3=20(LC 2), 2=79(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-80/119 BOT CHORD 1-3=-98/82 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=2DR; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14lb uplift at joint 3 and 60lb uplift at joint 2. 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard A WARNING - Ver}fy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Indjvidual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication qualify control, storage, delivery, erection and bracing, consult ANSVTPII Quality Criteria, DSB-89 and BCSII Building Component M 4 0 k Safety Informatlon available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. ITe Symbols PLATE LOCATION AND ORIENTATION 13/a * Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-' o * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated, Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1; National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1; Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all 0 other interested parties. U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TP11. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 fl, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Job Truss Type Oty Ply Centex Homes, Model20-29W FCJ3 MONO TRUSS 4 1 �� Job Reference o tional Universal Forest Product, Inc. E359, Ft. Pierce, A. 34946, James L. Shoaf 0-0-0 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:50 2007 Page 1 3-0-0 3 3-0-0 Scale: 1.5'=1 I 5.00 12 36 II 2 I T1 I I i 1 1 B1 3x4 = 5 4 0- -0 I 1-0-0 1-4-0 3-0-0 1-0-0 0-4-0 1-8-0 Plate Offsets X, 2:0-1-1 t,0-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) 0.00 5 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) 0.00 4-5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2004frP12002 (Matrix) Weight- 10lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc puriins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 1040-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 3=28/Mechanical, 4=-6/Mechanical, 5=24210-M Max Horz5=56(LC 5) Max Uplift3=-22(LC 5). 4=-6(LC 1), 5=126(LC 5) Max Grav3=28(LC 1), 4=12(LC 5), 5=242(LC 1) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-55/33, 2-3=-32/6 BOT CHORD 1-5=0/56, 4-5=0/0 WEBS 2-5=165/95 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf,, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 22 lb uplift atjoint 3, 6 lb uplift at joint 4 and 126 lb uplift atjoint 5. LOAD CASE(S) Standard A WARNING - VeriiN design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, r_0 Design valid for use only with Mrrek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite *300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component O Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. I Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated, Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 -1/16" O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside edge of truss. *This symbol indicates the _ . required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 . 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO SBCCI BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: besign Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 96-31, 95-43, 96-20-1, 96-67, 84-32 4922, 5243, 5363, 3907 9667, 9730, 9604B, 9511, 9432A 0 0 TEE-LOK' AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. CL 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber, 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Job Truss Type Oty Ply Centex Homes, Model 2029'B' TCJ3U MONO TRUSS 8 1 � Job Reference (optional) Universal Forest Product, Inc. E359, FL Pierce, Fl. 34946. James L. Shoaf 0-0-0 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:50 2007 Page 1 3-0-0 3 3-0-0 Scale: 1.5'=1 5.00 12 2 Ti 1 1 81 3x4 = 5 4 0- -0 1-0-0 1-4-0 3XG 3-0-0 1-0-0 0-4-0 1-8-0 Plate Offsets 1:0-0-0 0-0-0. 5:0-1-11.0-0 0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.09 Vert(LL) 0.00 5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.07 Vert(TL) 0.00 4-5 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) -0.00 3 n/a Na BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 10 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-" oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 3=28/Mechanical, 4=-0/Mechanical, 5=242/0$0 Max Horz5=56(LC 5) Max Uplift3=-22(LC 5), 4=-6(LC 1), 5=126(LC 5) Max Grav3=28(LC 1), 4=12(LC 5). 5=242(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-55/33, 2-3=-32/6 BOT CHORD 1-5=-0/56, 4-5=0/0 WEBS 2-5=-165/95 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip OOL=1.60. 2) `This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girders) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 22 lb uplift at joint 3, 6 lb uplift at joint 4 and 126lb uplift at joint 5. LOAD CASE(S) Standard i A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, �0 Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Appllcabllity of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrlcation, qualify control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component �'�� Safety Infofmatlon available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Syrnbols PLATE LOCATION AND ORIENTATION 13/q *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-1/0 * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry. Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 Ir O U roll E Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 0- OR AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection, 10. Plate type, size, orientation and location dimensions . shown indicate minimum plating requirements, 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Wek" Job Truss Truss Type Oty Ply Centex Homes, Model 2029'B' X06-016 CJ5 MONO TRUSS 4 1 Dm I Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946, JaOug 6 Shoaf 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:50 2007 Page 1 5-0-0 5-0-0 * Scale = 1:11 5.00 12 T1 3x6 II 2 81 / 3x4 = 4 2MM 0- -0 1-0-0 1 4-0 , 5-0-0 1-0-0 0-4-0 3-8-0 Plate Offsets X, 2:0-1-11,0-0 0 LOADING (psf) SPACING 2-M CSI DEFL in (loc) Udeff Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.15 Vert(LL) -0.01 4-5 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.09 Vert(TL) -0.01 4-5 >999 180 BCLL 10.0 Rep Stress Ina YES WB 0.02 Horz(TL) -0.01 3 n/a rda BCDL 10.0 Code FBC20041TPI2002 - (Matra) Weight: 16lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 54)-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 104)-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 3=106/Mechanical, 4=34/Mechanical, 5=304/0-8-0 Max Horz5=94(LC 5) Max Uplift3=70(LC 5), 5=-131(LC 5) Max Grav3=106(LC 1), 4=62(LC 2). 5=304(LC 1) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-101/40, 2-3=56/31 BOT CHORD 1-5=-0/94, 4-5=0/0 WEBS 2-5=246/149 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; *Lumber DOL=1.60 plate grip DOL=1.60. `t _ 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. _ 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 3 and 131 lb uplift at joint 5. LOAD CASE(S) Standard e WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with Mriek connectors. This design is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only.Additional temporary bracing to Insure stability during construcflon is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/T13I1 Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 * Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss securely seat. 0-1/0and 0 Cc O or4 x 2 orientation, locate plates 0 -1/16" from outside o edge of truss. F *This symbol indicates the required direction of slots in connector plates, * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings �Su (supports) occur. Icons vary but reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. 0 U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior 16. approval of a professional engineer. Install and load vertically unless indicated otherwise. MiTek° © 2004 Mitek® Job Truss Truss Type City Ply Centex Homes, Model2029'B' X06-016 CJ5U MONO TRUSS 8 1 2)" Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Ft. 34946. Ja6U(J 6 Shoaf 6.500 s Feb 5 2007 MfTek Industries, Inc. Thu Apr 05 07:21:50 2007 Page 1 5-0-0 5-0-0 Scale= 1:11.2 5.00 rl2 T1 i 2 i B1 l 30 = 4 MIMI 0- -0 i i 1-0 0 1 4 (�x6 11 5-0-0 1-M 0-4-0 3-8-0 Plate Offsets X 1:0-0-0;0- 0 5:0-1-11,0-0-0 LOADING (psf) SPACING 2-0-0 CS! DEFL in (too) Udefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.15 Vert(LL) -0.01 4-5 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.09 Vert(TL) -0.01 4-5- >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) -0.01 3 Na rda BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 16 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-M oc puriins. BOT CHORD 2 X 4 SYP No'2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEBS 2X4SYP No.2 REACTIONS (lb/size) 3=106/Mechanical, 4=34/Mechanical, 5=304/0.8.0 Max Horz5=94(LC 5) Max Uplift3=70(1-C 5), 5=-131(LC 5) Max Grav3=106(LC 1),4=62(LC 2),5=304(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=101/41, 2-3=56/31 BOT CHORD 1-5=0/94, 45=0/0 WEBS 2-5=246/149 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber.DOL=1.60 plate grip DOL=1.60. 2) 'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girders) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 Ib uplift at joint 3 and 131 lb uplift at joint 5. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, qualif control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/, * Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 -1�16n 0 O * For 4 x 2 orientation, locate Plates 0 -1/16" from outside edge of truss, o _ *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 software' or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated, Indicates location where bearings (supports) occur, Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1:-National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: .Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully Knots and wane atjoint locations are regulated by ANSI/TPI1 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10, Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise, © 2004 Mitek® Job Truss Truss Type Oty, Ply Centex Homes, Model 2029 W X06-016 EJ3 TRUSS 3 1 1-2-10 Job Reference (optional) -Page Universal Forest Product, Inc. E359, Ft. Pierce, Ft. 34946, James L. Shoaf - 6.500 s Fes( 9007 MTek Industries, Inc. Thu Apr 05 07:21:51 200 1 2-0-0 3 1 2-0-0 Scale: 1.5'=1 I . 5,00 12 2 i j T1 1 I I B1 3x4 0- 4 1-2-10 I 0-0-0 2-M 2-0-0 Plate Offsets X 1:0-1-8,0-0-3 LOADING (psf) SPACING 2-0-0 CS! DEFL in (loc) Ildefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.06 Vert(LL) -0.00 1 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.04 Vert(TL) -0.00 14 >999 180 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 Na Na BCDL 10.0 Code FBC2004fTP12002 =(Mat ix) Weight: 8lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 3-" oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. SLIDER Right 2 X 4 SYP No.2 1-1-3 REACTIONS (Iblsize) 1=8910-3-8, 4=20/Mechanical, 3=70/Mechanical Max Horz 1=57(LC 5) Max Upliftl=-07(LC 5). 4=-29(LC 3), 3=-55(LC 5) Max Gravi=89(LC 1), 4=40(LC 2), 3=70(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=39/0, 2-3=24/20 BOT CHORD 1-0=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 3) Refer to girders) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47lb uplift atjoint 1, 29lb uplift at joint 4 and 55 lb uplift at joint 3. LOAD CASE(S) Standard i A WARNING • Verify design parameters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MfTek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Infor-mation available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols - PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat, O * For 4 x 2 orientation, locate � Plates 0 - 1/16" from outside n. edge of truss. OR *This symbol indicates the required direction of slots in connector plates. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 * Plate location details available in MiTek 20/20 software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, / Installing & Bracing of Metal Plate Connected Wood Trusses. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties, 0 U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Miteko Job Truss Truss Type Oty Ply Centex Homes, at 2029'B' X06-016 EJ7 MONO TRUSS 6 1 Job Reference (optional) 20E0-00 Universal Forest Product, Inc. E359, Ft. Pierce, FI. James L. Shoaf 6.500 s Feb 5 2007 MTek Industries, Inc. Thu Apr 05 07:21:51 2007 Page 1 7-0-0 7-0-0 3 $ Scale = 1:15. 5.00 12 T1 2 1 131 3A = 4 2QF0-00 0-0-0 3x6 II 1-0-0 1-4-01 7-0-0 1-0-0 0-4-0 5-8-0 Plate Offsets MY): 5:0 1-11,0-0 0 LOADING (psf) SPACING 2-M CS! DEFL in (loc) Well L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.39 Vert(LL) -0.04 4-5 >999 360 MT20 244/190 TCDL . 15.0 Lumber Increase 1.25 BC 0.26 Vert(TL) -0.11 4-5 >604 180 BCLL 10.0 Rep Stress [nor YES WB 0.03 Horz(TL) 0.04 3 n/a n/a BCDL 10.0 Code FBC2004/fP12002 (Matrix) Weight: 22 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 3=174/Mechanical, 4=64/Mechanical, 5=38610-8-0 Max Horz5=131(LC 5) Max Uplift3=-110(LC 5), 5=-149(LC 5) Max Grav3=174(LC 1). 4=104(LC 2), 5=386(LC 1) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=154/56, 2-3=-84/52 BOTCHORD 1-5=-0/131,4-5=0/0 WEBS 2-5=358/228 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2)'This truss has been -designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 3 and 149 lb uplift at joint 5. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON TRIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with Mrrek connectors. This design Is based only upon parameters shown, and Is for an Individual bullding component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of bullding designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component M iTek® Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-'/76„ m O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside a edge of truss. *This symbol indicates the _ required direction of slots in connector plates. * Plate location details available,in MiTek 20/20 software or upon request. PLATE SIZE. The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings �Su (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: - Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building ❑ designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job Truss Truss Type Oty Ply Centex Homes, Model 2029'8' X06-016 EJ1U MONO TRUSS 18 1 Job Reference o Gonal 201-0-00 Universal Forest Product, Inc. E359, Ft. Pierce, FI. , James L. Shoat 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:51 2007 Page 1 7-0-0 ,. 7-0-0 3 Scale = 1:15. 5.00 12 T1 2 1 yl Ul 61 3x4 = 4 2%0-00 0-0-0 3x6 II 1-0-0 ,1-4-0, 7-0-0 1-0-0 0-4-0 5-8-0 Plate Offsets X 1:0-0-0 0.0-0 , 5:0-1-11,0-0-0 LOADING (psf) SPACING 2.0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.39 Vert(LL) -0.04 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.26 Vert(TL) -0.11 4-5 >604 180 BCLL 10.0 Rep Stress Incr YES WS 0.03 Haz(TL) 0.04 3 rrla n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) - Weight: 22lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (Ib/size) 3=174/Mechanical, 4=64/Mechanical, 5=38610-8-0 Max Horz5=131(LC 5) Max Uplift3=-110(LC 5), 5=-149(LC 5) Max Grav3=174(LC 1), 4=104(LC 2), 5=386(LC 1) FORCES (lb) - Maximum CompressionfMaximum Tension TOP CHORD 1-2=154/57, 2-3=84/52 BOT CHORD 1-5=-0/131, 4-5=0/0 WEBS 2-5=358/228 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. L' 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. - 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 3 and 149 lb uplift at joint 5. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individudI web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 .x 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING. Indicates location where bearings (supports) occur. Icons vary but IV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, .,Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 cr O U o_ O I — Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A c � ON TE,E-LOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required, See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses, 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. d 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified, 12. Top chords must be sheathed or puriins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 it, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty PlyCentex Homes. Model2029'B' X06-016 FG1 SPECIAL 1 2 Job Reference o Gonal UVLNMI Forest Product, Inc. E359, FL Pierce, Fl. 34946, James L. Shoat 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:56 2007jPM 1 I- 3-5-9 5-1-10 7-6-4 3-5-9 1-8-2 2-4-10 Scale= 1:12. i- " 3x4 = 1 3x4 II 2 3 .3x4 = 4 2x5 II i Ti W3 W3 101 Ll W1 W1 Ll B1 I I 5x6 = 2x5 II 2x5 II 9 7 10 6 11 5 4x6 = 0-0-0 0-0-0 i 3-5-9 5-1-10 7-6A 3-5-9 1-8-2 2-4-10 Plate offsets X 6:0-2-1 0-1-0 , 8:0.2-8.0-2-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) Ildefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.34 Vert(L-) -0.03 7 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.43 Vert(TL) -0.05 7.8 >999 240 BCLL 0.0 Rep Stress Ina NO WB 0.23 Horz(TL) 0.01 5 Na rda BCDL 5.0 Code FBC20041TP12002 (Matrbc) Weight: 86lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-M oc purlins, except end verticals. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2'Except* W1 2X6SYP SS, W1 2X6SYP SS REACTIONS (lb/size) 8=2444/0-3-8, 5=3964/0-3-8 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-8=-284/0, 1-2=-890/0, 2-3=3595/0, 3-4=-027/0, 4-5=-143/0 BOT CHORD 8-9=0/3595, 7-9=0/3595, 7-10=0/3595, 6-10=0/3595, 6.11=0/3595, 5-11=0/3595 WEBS 2.8=-2913/0, 2-7=131/1069, 3-6=26/1632, 3-5=3694/0 NOTES 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 -1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 4,z 1 row at 0-9-0 oc. R 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loadsatoted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) Concentrated loads from layout are not present in Load Case(s): #21st chase Floor, #3 2nd chase Floor. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 602 lb down at 1-10-4, 806 lb down at 1-10-4, 602 lb down at 3-104, 806 lb down at 3-10-4, 602 lb down at 5-10-4, 806 lb down at 5-10-4, and 602 lb down at 7-10 3, and 806 lb down at 7-10-4 on bottom chord. The desigrdselection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase--1.00 Uniform Loads (plf) Vert: 1.4=100, 5.8=10 Concentrated Loads (lb) Vert: 5=-1408(F=-806, B=-602) 9=1408(F=-806, B=602)10=1408(F=-806, B=602)11=1408(F=-806, B=-602) e WARNING - Verljg design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Indlyidual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication,: qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iT k° Safe Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Platelocation details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated, Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal . Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, 'Installing & Bracing of Metal.Plate Connected Wood Trusses. 0 m O 2 U r� Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all pC other interested parties. O U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber, 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified, 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13, Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Miteke Job Truss Truss Type Qty ply Centex Homes, Model 2029'B' X06-016 FG2 SPECIAL 1 2 Job Reference (optional) LtLXWI Forest Product. Inc. E359, Ft. Pierce. R. 34946, James L. Shoaf 6.500 s Feb 5 2007 MiTek Industries. Inc. Thu Apr 05 07:21:56 VQjjtage 1 5-0-8 P4 10-04 15-0-12 5-0-8 0-5-12 4-6-0 5-0-8 Scale =1:25. 3x4 II 3x10 = 3x4 It 1 2 3 3x4 = 4 W3 4 W3 2 B1 5x7 7 9 6 5 2x5 II 3x5 = US = 0-0-0 0-0-0 5-0-8 P-6-1 10-0-4 15-0-12 5-0-8 0-5-12 4-6-0 5-0-8 Plate Offsets X 3:0-1-12 0-1-8 8:0-2-12,0-2-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Vd PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.24 Vert(LL) -0.08 6-7 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.26 Vert(TL) -0.13 6-7 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.27 Horz(TL) 0.02 5 n/a n/a BCDL 5.0 Code FBC2004frP12002 (Matrix) _ Weight: 170lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10.0.0 oc bracing. WEBS 2 X 4 SYP No.2 'Except' W12X6SYP SS, W12X6SYP SS REACTIONS (lb/size) 8=1136/0-1-8, 5=992/0-3-0 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-8=266/0, 1-2=-407/0, 2-3=2715/0, 3-4=-368/0, 4-5=259/0 BOT CHORD 7.8=0/3233, 7-9=0/3233, 6-9=0/3233, 5-0=0/2715 WEBS 2-8=2926/0, 2-7=0/432, 2-6=536/0, 3-6=0/155, 3-5=-2429/0 NOTES 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Tap chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 -1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 4 -1 row,at 0-9-0 oc. 2) All loads are considered equally applied to -all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted'as (F) or (B), unless otherwise indicated. 3) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 8. 4) Recommend 2x6 strongbacks, on edge• spaced at 10-0.0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 522 lb down at 5-6-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Floor. Lumber Increase=1.00• Plate Increase=1.00 Uniform Loads (plf) Vert: 14=-100, 5-8=-10 Concentrated Loads (lb) Vert: 9=522(F) A WARNING - VeryJ, design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with Mrrek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erectlon and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths, Apply plates to both sides of truss and securely seat. vlo 0 O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside o_ edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but EV reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction, DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95A3, 96-20-1, 96-67, 84-32 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury I . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a. 5. Place plates on each face of truss at each joint and OP embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Type Oty PlyT2jo tex Homes, Model2029'B' X06-016 7FG3 ]SPECIAL 1 Reference o tional -ilouerhpl Forest Product, Inc. E359, FL Pierce, Ff. 34946, James L. Shoat 6.500 s Feb 5 2007 AfTek Industries, Inc. Thu Apr 05 07:21:56 20070%981 r 3-5-8 7-10-12 8-3 4 11-4-4 3-5-8 4-5-3 0-4-8 3-1-0 Scale = 1:18. 1.50 11 3xe = 3x4 = 3x4 11 1 2 3 9 4 T1 W1 W3 4 W3 W1 . B1 4x6 = " 7 6 10 5 - 2x5 11 3x4 = 4x6 = 0-0-0 0-0-0 3-5-8 7-10-12 3 4 11-4-4 3-5-8 4-5-3 0-4-8 3-1-0 Plate Offsets X, 6:0.1-12 0-1A LOADING (psf) SPACING 2.0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.21 Vert(LL) -0.03 6-7 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.21 Vert(TL) -0.05 6-7 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.14 Horz(TL) 0.01 5 Na Na BCDL 5.0 Code FBC20041TP12002 (Matrix) - Weight: 131 Ito LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0.0 oc purlins, except end verticals. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 *Except* W 1 2 X 6 SYP SS, W 1 2 X 6 SYP SS REACTIONS (lb/size) 8=816/0-1-8, 5=135210.3-8 FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1.8=152/0, 1-2=171/0, 2-3=2290/0, 3-9=-405/0, 4-9=-005/0, 4-5=356/0 BOT CHORD 7-8=0/1653, 6-7=0/1653, 6-10=0/2290, 5-10=0/2290 WEBS 2-8=169610, 2-7=0/12, 2-6=0/664, 3-6=0/282, 3-5=-2030/0 NOTES 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc, 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc. Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Provide mechanical connection (by others) of truss to Clearing plate at joint(s) 8. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer - ends or restrained by other means. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 683 lb down at 8-34 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASF(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-9=-100, 4-9=-200, 5-8=-10 Concentrated Loads (lb) Vert 10=683(13) A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fdbrlcation,,qualifyy control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety InfoTrmation available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 63719. Symbols PLATE LOCATION AND ORIENTATION 13/a * Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0-1/16° O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate. location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 x 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING, Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate :Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERSAETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 TEE-LQK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e•g, diagonal or X-bracing, is always required. See BCSI1. 2• Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. 0 U 4• Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9• Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design, 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14• Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type aY Ply Centex Homes, Model 2029'B' X06-016 FG4 SPECIAL 2 1 Job Reference o tional Universal Forest Product, Inc. E3�90F� Pierce. FI. 34946, James L. Shoaf 6.500 s Feb 5 2007 MiTek Industries,-6 u Apr 05 07:21:5T 2007 Page 1 1 3x4 _ 3-6-4 2 1.5x4 it r 3-6-4 Scale = 1:8. T7 W1 W1 B1 4x6 = 5 6 3 0 0 �axs II 3-6-4 3-6-4 LOADING (psf) TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 SPACING 2-0-0 Plates Increase 1.00 Lumber Increase 1.00 Rep Stress Incr NO Code FBC2004frP12002 CSI TC 0.68 BC 0.20 WB 0.00 (Matrix) DEFL in (loc) Weill L/d Vert(LL) -0.01 3-4 >999 480 Vert(TL) -0.02 3-4 >999 240 Horz(TL) 0.00 3 n/a nla PLATES GRIP MT20 244/190 Weight: 21 lb LUMBER ' BRACING ' TOP CHORD 2 X 4 SYP No.2 TOP CHORD' Structural wood sheathing directly applied or 3-6-4 oc purlins, except end verticals. BOT CHORD 2 X 6 SYP SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 4=843/0-1-8, 3=6931Mechanical FORCES (lb) - Maximum Compression'Maximum Tension TOP CHORD 1-4=323/0, 1-2=0/0, 2-3=-32310 BOT CHORD 4-5=010, 5-6=0/0, 3-6=0/0 WEBS 1-3=-0/0 NOTES 1) Refer to girder(s) for truss to truss connections. 2) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 429 lb down at 0-5-12. and 429lb down at 2-5.12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Floor: Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-2=200, 3.4=10 Concentrated Loads (lb) Vert: 5=-429(F) 6=-429(F) e e WARNING • Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building deslgner - not truss designer. Bracing shown 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 r_O is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quallty control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. MN Tek° Symbols PLATE LOCATION AND ORIENTATION 14- 13/14 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. vlo 0 cc O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside o., edge of truss. _ *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings uld, (supports) occur. Icons vary but reaction section indicates joint 9F number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: - Design Standard for Bracing. BCSI1; 'Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on Inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 0 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior 16. approval of a professional engineer. Install and load vertically unless indicated otherwise. Mi! MiTeke • V\/\\1 a © 2004 Mitee Job Truss Truss Type Oty Ply Centex Homes. Model 2029'B' X06-016 GE1 VALLEY 1 1 Job Reference o Gonal (JOLNUWI Forest Product, Inc. E359, Ft. Pierce, FI. 34946. James L. Shoal 6.500 s Feb 5 2007 MiTek Industries• Inc. Thu Apr 05 07:21:57 2007 Page 1 34-12 6-9-8 3-4-12 3-4-12 Scale = t:+o. 46 = i .; 2 I s.00 12 i I T 1 ST1 3 ! 1 . I B+ I 0-0-0 I i fi-9-8 6-9-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl lid PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.11 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.07 Vert(TL) n/a n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) 0.00 3 n/a Na BCDL 10.0 Code FBC2004/TPI2002 (Matra) Weight- 20 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD' Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=119/6-9-8, 3=119/6-9.8, 4=242/6-9-8 Max Horz 1=18(LC 5) Max Upliftl=-45(LC 5), 3=48(LC 6), 4=-47(LC 5) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=-43/27, 2-3=-43/19 BOT CHORD 1-4=0/13, 3-4=0/13 WEBS 2-4=175/67 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf,, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed : Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 3x4 MT20 unless otherwise indicated. .1 , - 5) Gable requires continuous bottom chord bearing. -1Z 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 45 lb uplift at joint 1, 48 lb uplift at joint 3 and 47 lb uplift at joint 4. LOAD CASE(S) Standard A WARNING - Veri,& design parameters and READ NOTES ON Tffi8 AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Addiflonal temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualif�-control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSIi Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. MqTe Symbols PLATE LOCATION AND ORIENTATION 13%a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 0-1/0and securely seat. * For 4 x 2 orientation, locate plates 0 -1/0 from outside edge of truss. *This symbol indicates the required direction of slots in connector plates, * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. 0 cc O U o_ O P Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA ICBO BEARING - SBCCI Indicates location where bearings �Sul (supports) occur, Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1:. National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, -Jnstalling & Bracing of Metal Plate Connected Wood Trusses. 96-31, 95-43, 96-20-1, 96-67, 84-32 4922, 5243, 5363, 3907 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O v 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TP11. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design, 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Type Oty Ply Centex Homes, Model 2029'B'X06-016 GF2 TG:LE 1 1 Job Reference (optional) UOLXW1 Forest Produ—Ct; Inc. E359, FL Pierce, FI. 34946. James L. Shoaf 6.500 s Feb 5 2007 MTek Industries, Inc. Thu Apr 05 07:21,57 2007 Page 1 6-1-12 12-3-8 6-1-12 6-1-12 Scale = 1:19. 4x6 = 3 5.00 F12 4 2 T ST2 1 ST1 ST1 1 LJ 81 0-0-0 12-3-8 12-3-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.12 Vert(LL) Na Na 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.08 Vert(TL) rda rVa 999 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) 0.00 5 Na Na BCDL 10.0 Code FBC2004rrP12002 (Matrix) Weight: 42lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD` Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SYP No.2 REACTIONS (Ib/size) 1=127/12-3-8, 5=127/12-3-8, 7=73/12-3-8, 8=325/12-3-8, 6=325/12-3.8 Max Horz 1=-37(LC 6) Max Upliftl=32(LC 5). 5=-38(LC 6), 8=137(LC 5). 6=136(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-47/47, 2-3=-44/65, 3-4=-04/61, 4-5=-47/47 BOT CHORD 1-8=0/35, 7-8=0/35, 6-7=0/35, 5-6=0/35 WEBS 3-7=-72/1, 2-8=233/140, 4-6=-233/140 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.0psf; Category 11; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load noncorxmrrent with any other live loads. 4) All plates are 3x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 32 lb uplift atjoint 1, 38 lb uplift at joint 5, 137 lb uplift atjoint 8 and 136 lb uplift at joint 6. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualitcontrol, storage, delivery, erection and bracing, consult ANSIMI Quality Criteria, DSB-89 and BCSII Building Component 0 l Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. 1 M ITe Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. _1�16n 0 cc O * For 4 x 2 orientation, locate 0 plates 0 -1/0 from outside a - edge of truss, o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 x 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL -BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89:' Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95A3, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGenera.l Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required, See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses, 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10, Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty Ply Centex Homes, Model 2029'B' X06-016 HJ3 0-0-0 MONO TRUSS 2 1 1-2-12 Job Reference o tional Universal Forest Product, Inc: E359, FL Pierce, FI. 34946, James L. Shoaf 6.500 s Feb 5 2007 MiTek lodgsliges, Inc. Thu Apr 05 07:21:58 2007 Page 1 2-9-15 3 2-9-15 scale:l.s=1 3.54 12 2 T1 1 H B1 3x4 Z 0- 4 1-2-12 0-0-0 y� 2-9-15 2-9-15 Plate Offsets X 1:0-2-4 0-1-9 LOADING (pso SPACING 2.0.0 CSI DEFL in (loc) Well Idd PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.08 Vert(LL) 0.01 1.4 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.06 Vert(TL) -0.01 1-4 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.00 Horz(TL) 0.00 3 rda rda BCDL 10.0 Code FBC2004rrP12002 (Matrix) Weight 11 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-2-15 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid celing directly applied or 10-0-0 oc bracing. SLIDER Right 2 X 4 SYP No.2 1-3-3 REACTIONS (Ib/size) 1=44/0-3-8, 3=68/Mechanical, 4=20/Mechanical Max Horz1=21(LC 3) Max Upliftl=-53(LC 3), 3=-41(LC 3), 4=-43(LC 3) Max Grav1=52(LC 2), 3=6B(LC 1), 4=47(LC 2) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=-19/0, 2-3=14/13 BOT CHORD 1-4=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girders) for truss to truss connections. .11 4) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 53 lb uplift at joint 1, 41 lb uplift at joint 3 and 43 Ito uplift at joint 4. 5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 Trapezoidal Loads (pit) Vert: 1=0(F=35, 13=35) 6-3=-74(F=-2, B=-2), 1=0(F=10, B=10)-to-4=21(F=1, B=-1) s A WARNING - Ver!Jy design parnm.eters and READ NOTES ON TSIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quallf control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component M iTe ° Safety Information available from Truss Plate Institute, 5B3 D'Onofrio Drive, Madison, W153719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss, *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but reaction section indicates joint 9F number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ';Connected Wood Trusses. 0 cc O U Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBEREDAETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc 0 other interested parties. O U 4. Cut members to bear tightly against each other. CL 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment,in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft, spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior 16. approval of a professional engineer. Install and load vertically unless indicated otherwise. MiTek° 14 11111 © 2004 Mitee Job Truss Truss Type City Ply Centex Homes, Model 2029'B' X06-016 FIJ7 MONO TRUSS 2 1 Job Reference to6onal 20"2 Universal Forest Product, Inc. %Wt Pierce, FI. 34946, James L Shoat 6.500 s Feb 5 2007 MTek Industries, Ind. Thu Apr 05 07:21:58 2007 Page 1 5-10-4 9-10-13 j 5-10-4 4-0-9 i i Sc e 1 6. i 10 3.54 FIT i 3 9 T1 I I W2 W1 2 I 1 B1 11 7 12 6 5 2011l0-02 i 3x6 11 _ 0-0-0 l 1-5-0 ,1-10-14 5-8-15 9-10-13 1-5-0 0-5-11 3-10-5 4-1-13 Plate Offsets 8:0-1-9,0-0-0 LOADING (psf) SPACING 2-" CSI DEFL in (loc) Vidal Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.40 Vert(LL) -0.03 6-7 >999 360 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.47 Vert(TL) -0.09 6-7 >999 180 BCLL 10.0 Rep Stress Incr NO WB 0.12 Horz(TL) -0.04 4 Na Na BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight: 39lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M or, bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 4=153/Mechanical, 5=224/Mechanical, 8=524/0-11-5 Max Horz8=131(LC 3) Max Uplift4=-85(LC 3). 5=-75(LC 3), 8=239(1-C 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=387/89, 2-9=-039/117, 3-9=-415/126, 3-10=-56/1, 4-10=29/35 BOT CHORD 1-8=-81/382, 8.11=176/382, 7-11=176/382, 7-12=176/382, 6-12=176/382, 5-6=0/0 WEBS 3-7=0/126, 3-6=-419/193, 2-8=-302/163 NOTES 1) Wind: ASCE 7-02;130mph (3-second gust); h=20ft; TCDL=4.2psf, BCDL=3.Opsf; Category II; Exp B; enclosed; MIWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurre6t with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Refer to girders) for truss to truss connections. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 85 lb uplift at joint 4, 75 lb uplift at joint 5 and 239 lb uplift at joint 8. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 11 lb down and 42 lb up at 4-3-11. 11 lb down and 42lb up at 4-3-11, and 36 Ib down and 42 Ib up at 7-1-10, and 36 Ib down and 421b up at 7-1-10 on top chord, and 22lb down at 7-1-10, 221b down at 7-1-10, and 29 Ib up at 44-11, and 291b up at 4-3-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 141=70, 1-6 -20 Concentrated Loads (lb) Vert: 9=84(F=42, B=42) 10=73(1==-36, B=-36)12=-27(1`=14, 13=14) A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with Mrrek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individudl web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 cc O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside a. edge of truss. 0 *This symbol indicates the _ required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury I . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. O U 4. Cut members to bear tightly against each other. a 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator, General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless Indicated otherwise. © 2004 Mitek® Job Truss Truss Type Oty Ply Centex Homes. Model 2029'B' X06-016 HJ7U MONO TRUSS 4 1 Job Reference o tional 20110-02 Universal Forest Product, Inc. ��ft. Pierce, R. 34946. James L. Shoaf 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:58 2007 Page 1 �— 5-10-4 9-10-13 5-104 4-0-9 $ S(Tle = 1.16. 3.54 12 3 9 T1 w2 wi 3x6 I 2 1 B1 10 7 6 5 2 2 0-0-0 1-5-0 ,1-10-10, 5-8-15 9-10-13 1-5-0 0-5-11 340-5 4-1-14 Plate Offsets X 2-0-1-9,0-0-0 LOADING (psf) SPACING 2-0.0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.50 Vert(LL) -0.03 6-7 >999 360 MT20 2441190 TCDL 15.0 Lumber Increase 1.25 BC 0.49 Vert(TL) -0.10 6-7 >932 180 BCLL 10.0 Rep Stress Incr NO WB 0.18 Horz(TL) -0.04 4 Na Na BCDL 10.0 Code FBC2004/TPI2002 (Matron) Weight: 39 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (lb/size) 4=279/Mechanical, 5=339/Mechanical, 8=39510-11-5 Max Horz8=164(LC 3) Max Uplift4=-161(LC 3). 5=-95(LC 3), 8=167(LC 3) FORCES (lb) - Maximum CompressionlMaximum Tension TOP CHORD 1-2=-568/106, 2-9=-617/115, 3-9=-604/127, 3A=-77/60 BOT CHORD 1-8=106/564, 8.10=253/564, 7-10=253/564, 6-7=-253/564, 5-6=0/0 WEBS 3-7=0/142, 3-6=-020/278, 2-8=-203/92 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Fxp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Refer to girder(s) for truss to truss connections. -. 5) Refer to girders) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 161 lb uplift at joint 4, 95 lb uplift at joint 5 and 167 lb uplift at joint 8. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 11 lb down and 42lb up at 4-3-11, and 11 lb down and 42 lb up at 4-3-11 on top chord, and 29 lb up at 4-3-11, and 29 lb up at 4-3-11 on bottom chord. The desigr✓selection of such connection device(s) is the responsibility of others. - 8 In the LOAD CASES section, loads applied to the face of the truss are noted as front --- () PPI� (� or back (B). LOAD CASE(S) Standard 1) Regular: Lumber Increase--1.25, Plate Increase=1.25 Concentrated Loads (lb) Vert: 9=84(F=42, B=42) Trapezoidal Loads (plf) Vert: 1=0(F=35, B=35)-to-0=173(F=-52, B=-52), 1=0(F=10, B=10}to-5=49(F=15, B=15) s A WARNING - Verify design parameters and READ NOTES ON TBIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite 0300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component n A iTe O k Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. 1 Y, Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside CL edge of truss. o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4. X 4. perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPII t National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89:. Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. a- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15, Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mite,0 Job Truss Type Oty Ply Centex Homes, Model 2029'B' X06-016 W2 TVALIEY 1 1 Job Reference o tlonal Universal Forest Product, Inc. E359, Ft. F"eg!71. 34946. James L. Shoaf 6.500 s Feb 5 2007 MiTek �dustnes, Inc. Thu Apr 05 07:21:56 2007 Page 1 2-0-0 2-0-0 ,. Scale = 1:5.1 5.00 12 1 T 1311 0 2-0 0 -0-03x4 2 LOADING (psf) SPACING 24).0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.02 Vert(LL) rrla Na 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.01 Vert(TL) n/a We 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2004/TPI2002 (Matra) Weight: 5 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-M oc purfins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. REACTIONS (lb/size) 1=45/2-M, 2=35/2-0-0, 3=10/2-M Max Horz1=24(LC 5) Max Upliftl=-9(LC 6), 2=24(LC 5) Max Grav1=45(LC 1). 2=35(LC 1). 3=20(LC 2) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-15/13 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psF BCDL=3.Opsf; Category Il; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Gable requires continuous bottom chord bearing. 4) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 9 Ibliplift atjobt 1 and 24lb uplift at joint 2. LOAD CASE(S) Standard s A WARNING - verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. _I/16" O * For 4 x 2 orientation, locate 0111 plates 0 - 1/16" from outside a_ edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but Ev'' reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1:;National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89:. Design Standard for Bracing. BCSI1: Building Component Safety Information, . Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7. 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A Qi TEE-LOK' AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties, O U 4• . Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1 7• Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8• Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13• Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14, Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16• Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Thus Truss Type pty Ply Centex Homes, Model 2029'9 X06-016 MV4 I VALLEY 1 1 Job Reference (optional) Universal Forest Product, MF®59, Ft. Pierce, R. 34946; James L. Shoaf 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:513 2007 Page 1 4-0-0 4-0-0 Scale =1:8. 5.00 12 T W1 1 B1 0- 4-M 4-0-0 LOADING (psf) SPACING 2-0.0 CS1 DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.16 Vert(LL) rVa - Na 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.09 VeaM) n/a - n/a 999 BCLL 10.0 Rep Stress Ircr YES .WB 0.00 Horz(TL) 0.00 Na n/a BCDL 10.0 Code FBC2004/TPI2002 (Matrix) Weight 13lb - LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEBS 2 X 4 SYP No.2 REACTIONS (Ib/size) 1=141/4-M, 3=141/4-" Max Hors 1=58(LC 5) Max Uplift1=35(LC 5), 3=-60(LC 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-06/34, 2-3=109/69 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.0psf, Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 35 lb upikat joint 1 and 60 lb uplift at joint 3. LOAD CASE(S) Standard e WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, r_0 Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Indlvidual web members only. Additlonal temporary bracing to Insure stability during construction Is the responsibility of the erector. Additlonal permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPIi Quality Criteria, DSB-89 and BCSIi Building Component M iT k° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719, Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. a o *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information; Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all � other interested parties. 0 U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13, Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. .M1 - MiTek° 2004 Mitek® Job Truss Truss Type Oty Ply Centex Homes, Model 2029'B' X06-016 MV6 VALLEY 1 1 _ Job Reference oGonal Universal Forest PcMc� Inc. E359, FL Pierce, FI. 34946, James L. Shoaf 6.500 s Feb 5 2007 tutTek Industries, Inc. Thu Apr 05 07:21:59 2007 Page-1 6-0-0 6-0-0 2 stele =tat. 5.00 12 T W1 1 B1 0 6-0-0 6-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) 1/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.42 Vert(LL) n/a - Na 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.25 Ved(TL) n1a - rda 999 BCLL 10.0 '. Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 20lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. WEBS 2 X 4 SYP Not REACTIONS (Ib/size) 1=231/6-0-0, 3=231/6-0.0 Max Horz 1=96(LC 5) Max Uplift1=58(LC 5). 3=98(LC 5) FORCES (lb) - Maximum CompresslordMaximum Tension TOP CHORD 1-2=58/55, 2-3=179/113 BOT CHORD 1-3=0/0 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); 11=2011; TCDL=4.2psf,- BCDL=3.Opsf; Category II: Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 lb uplift at joint,1 and 98 lb uplift at joint 3. LOAD CASE(S) Standard ,. A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Addlflonal temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 -1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates, * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89:, Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on Inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other Interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPII, 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Truss Type aY PiyCentex Hames, Model 2029'B' X06-016 VALLEY 1 1 Job Reference o tional Universal Fore"tduct, Inc. E359, Ft. Pierce, R. 34946, James L. Shoaf 6.500 s Feb 5 2007 MSTek Industries, Inc. Thu Apr OS 07:21:59 2007 Page 1 � 8-0-0 8-0-0 3 s_ Scale = t:ta. 5.00 12 W1 T 2 ST1 1 61 0- i 8-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.21 Vert(LL) Na - Na 999 MT20 244/190 TCDL 1¢.0 Lumber Increase 1.25 BC 0.12 Vert(TL) Na - Na 999 BCLL� 10.0 Rep Stress Irtcr YES WB 0.03 Horz(TL) 0.00 Na Na BCDL 10.0 Code FBC2004ffP12002 (Matrix) Weight: 291b LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except erxl verticals. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2X4SYP No.2 OTHERS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=10318-0-0, 4=136I8-0-0, 5=403/8-0-0 Max Horz1=133(LC 5) Max Uplift4=-58(LC 5), 5=1 T1(LC 5) FORCES (lb) -Maximum CompressioNMaximum Tension TOP CHORD 1-2=-124/57, 2-3=-63/30, 3A=106/67 BOT CHORD 1-5=0/0, 45=0/0 WEBS 2-5=-313/198 NOTES 1) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 2) *This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) All plates are 3x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 lb uplift atjcint 4 and 171`Ib uplift atjoint 5. LOAD CASE(S) Standard A WARNING -Verify design parameters and READ NOTES ON THIS AND REVERSE 87DE BEFORE USE. 14515 N. Outer Forty, � Design valid for use only with MlTek connectors. This design Is based only upon parameters shown, and is for an Individual building component. Suite #300 Applicability of design parameters and proper fncorporat(on of component is responsibility of building designer -not truss designer. Bracing shown Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iT 0 O Job ]MV8 Symbols PLATE LOCATION AND ORIENTATION 13/a * Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 O * For 4 x 2 orientation, locate 0 plates 0 - 1/16" from outside edge of truss. o *This symbol indicates the ., required direction of slots in connector plates. r * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL'BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING' Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1:: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all cc other interested parties. 0 U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber, 9. Camber is a non-structural consideration and'is the responsibility of truss fabricator, General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. 11. Lumber used shall be of the species.and size, and in all BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior 16. approval of a professional engineer. Install and load vertically unless indicated otherwise. MiTeke © 2004 Mitek® • 1 1 : 11, /1 1 1 11 1 1 1 11 g.........1..................... �����������������1������������������1���1�������������������������1������1�1������������������1 �1�������• ♦11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111�111111111 �1111111111/1/11111111111111111111111111111111111111♦111111111111111111111111111111111111111111111111111111111111111111111111111111 ♦11111111• .11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111�11111111• �11111111111111111111111111111111111111111111111♦11♦♦111111111111111♦♦1111111111111111111111111111111111111111111111111111111111111�11111111• 1 �111111111111111111111111111111111111 � �111111111111 �11111111111111 �111111111111111111111/11111111111111111111111111111111111111111111111111111111111111111111/111111111111111111/11111111111111111111111111111111111111111111111111111111111111111111 �1111111���111111 �1� 111 �� �1111111� � 1 �1111111111111� 111111111111111111111111111111111111111/111111111111111111111111111111� 111111111111111111111111111111111111� 11111•1111111111� 111111111111111/111111111111111111111111111111111 ��11111111111111111111111 �1111/111111� 1 �111 �111•��1� 111 � �111111� 1♦11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111♦♦111111111111111111111111�11111111• �1111111111111111111111111111111111111111111111♦♦111111111111111111111111111111111111111111111111111111111111111111111♦♦11111111111 ♦11111111• �111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 �111111111111111111 �111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111� 111111111111111111111111111111111111111��111111 �1� 11111� 1.1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111�111111111 �11111111111111111111111111111111111111.1111111♦11111111111111111111111111111111111111111111111♦•111111111111111111111111111111111♦ ♦11111111• ♦♦111111111111111111111111111111111111111111♦♦111111111111111111111111111111111111111111111111111111111111111111111111111111111111�11111111♦ �1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 ♦11111111• ♦♦11111111111111111111111111111111111111111111111111111111111111111111111♦♦111111111111111♦♦11111111111111111111111•♦1111111111111�11111111♦ 11111111111111111111111111111111111111111111111111111111111111111111111111♦111111111111111111111111111111111111111111111111111111�11111111� �1 ••11111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111�11111111� ••111111111111111♦111111♦•1111111111111111111111111/111111111111111111111111♦111111111111111111111111111111111111111111111111111111�1111111♦ �11111111111111111111111� 111 �11 �11 �11111111111111111111111111111111111111111111111111111111/111111111111/111111111/1� � 11111111111111111111111111111111111111� 11111111111111111111111111111 11111 �11111111111111111� 111111111111� 1111111 �11 � �1111111111��1111 � �1111111� /♦1111111111111111111111111111111.1111111111111111111111111.111111111111111111111111111111111111♦♦•111111111111111111111111111111�1.1111111 �1 �11111111 �11 �1111111111111111111111111111111111111111 �11111111 �1111111111111� 1 111 �1111111111111111111111111111 �11111111111111111111111111111111111111111111111111111111111111� �11111 �1111 �11111111111/11 �111111 �1111111111111111111111111��111111111 �1 1� 1111111111111111111111111111111•♦111111111111111111111111111.1111111111111111111111111111111111111 1111111111111111111.111111/111♦ ♦111111�1� ♦♦111111111111111111111111111111111111111111111.11111111111.111111111111111111111111111111111111111111111111111111111111111.111111�11111111� �1111111111111.1111111111111♦1111111111111111111111111111111.111111.111111111111111111111111111111111♦1111111111111111111111111111111111111• 1♦111111111111111111111111111111111111111111♦♦111111111111111111111111111111111111111111111111111111111111111111111111111111111♦•1�11111111� �111111111111111111111111111111111111111♦♦11111♦111111111111111111111111111111111111111111111111111111•♦11111111111111111111111111111.11111♦ ♦♦111111♦•111111111111111111111.1111111111111111111111111••1111111111111111111.111111111111111111111111111111111111111111111111111�11111111• �1111111111111111111.111.11111111111111111111111111111111111.11111111111111111111•♦11111111111111./11111111111111111111111111111111�11111111� •�111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111�11111111� 11 � ��1�1 � � � � � � � � ��1�1�1�1�1�1�1:1�1�1�1�1 � � 1 � � � � � ��1 � � ��1�1�1 � � ��1�•�1�1�1�1�1�1�1�1�1�1�1 ��1�1�1�1�1�1�� 1 � � �11�1 ��1�1 ��1�1�1�1�1�1�1�1�1�1�1�1 ��� 1 ��1 � � 1�1 ��1�1�1 � � 1 ��1�1�1�1�1�1�1 � � ��1�1�1�1 � � � ��1 ��1�1�11�� � � ��1�1�1 1 1 1 a • 1 1 • 1 •1 1 1 1 1 11 1 •/ � 1 :• 11. • 1 1 1/ • 11 " • 1 1 •1 1 • •1 •/ . - 1 1 •1 IWery�jpara• NOTES / I REVERSE SZD.EBEFORE;• Design valid for use only with MITek connectors. This design Is based only upon parameters uilding component. and Is for an Individual • Suite 11 Applicability of design parametersproper componentresponsibility building• designer designer.wn, Bracing shown Chesterfield,• 63017 Is for lateral support of Individual web members only. - _ construction Is _ responsibility_ Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 X O *For 4 x 2 orientation, locate � plates 0 - 1/16" from outside n. edge of truss. _ *This symbol indicates the _ required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: ` : Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 4. Cut members to bear tightly against each other, 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator, General practice is to camber for dead load deflection, 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15, Do not cut or alter truss member or plate without prior approval of a professional engineer, 16. Install and load vertically unless indicated otherwise. © 2004 Mitek® Job Truss Type Cry Ply Centex Homes, Model 2029'B' X06-016 IT'uss V4 VALLEY 1 1 Job Reference o tional U0b"I Forest Product, Inc. E359, Ft. Pierce, FI. 34946. James L. Shoat 6.500 s Feb 5 2007 MTek Industries, Inc. Thu Apr 05 07:21:59 2007 Page 1 2-1-12 4-3-8 2-1-12 2-1-12 �. 2 scale =1 s. 5.00 12 T 1 3 1 131 0-0-0 4-3-8 r 4-3-8 Plate Offsets X, 2:0-2-0 Ed e LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.03 Vert(LL) rda n/a 999 MT20 244/190 TCDL 15.0 Lumber Increase 1.25 BC 0.08 Vert(TL) Na - n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 Na n/a BCDL 10.0 Code FBC2004/TPI2002 (Mal x) Weight: 11 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-3-8 oc puriins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (Ib/size) 1=128/4-3-8, 3=128/4-3-8 Max Horz 1=1 O(LC 5) Max Uplift1=36(LC 5), 3=-36(LC 6) FORCES (lb) - Maximum CompressioNMaximum Tension TOP CHORD 1-2=-144/56, 2-3=144/56 BOT CHORD 1-3=-42/119 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psF, BCDL=3.Opst Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 3x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 36 lb uplift at joint 1 and 36 lb uplift at joint 3. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responslbllity of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication qualify control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Bullding Component ° Safety Inf6rmation available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION 13/a *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings U14 (supports) occur. Icons vary but IiF reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPII National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89:. - Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 cc O 2 O Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A 0 TEE10K� FlawAll MIN �� AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all rr other Interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber, 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is Installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job Truss Truss Type ob Ply Centex Homes, Model 2029'B' X06-016 Vfi VALLEY 1 1 Job Reference (optional) tJattWl Forest Product, Inc. E359, FL Pierce, FI. 34946. James L. Shoaf 6.500 s Feb 5 2007 MSTek Industries, Inc. Thu Apr 05 07:22:00 2007 Page 1 4-1-12 8-3-8 4-1-12 4-1-12 g Scale = 1:13. 46 = 2 5.00 V2 i i T ST1 1 I i 3 1 • B1 I 0-0-0 i 8-3-8 i i 8-3-8 Plate Offsets X, 4:0-1-140-1 8 LOADING (psf) SPACING 2-0.0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.19 Vert(LL) n/a- Na 999 MT20 244/190 TCDL 15.0 lumber Increase 1.25 BC 0.11 Vert(TL) n/a n/a 999 BCLL 10.0 Rep Stress Incr YES WB 0.02 Horz(TL) 6.00 3 n/a n/a BCDL 10.0 -Code FBC2004ffP12002 (Matrix) Weight: 25lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 1G." oc bracing. OTHERS 2 X 4 SYP No.2 REACTIONS (lb/size) 1=152/8-3-8, 3=152/8-3-8, 4=310/8-3-8 Max Horz1=-23(LC 6) Max Upliftl=-57(LC 5), 3=-61(LC 6), 4=-60(LC 5) FORCES (lb) - Maximum CompressiorVMaximum Tension TOP CHORD 1-2=-55/35, 2-3=•55/25 BOT CHORD 1-4=0/17, 3-4=0/17 WEBS 2-4=-225/86 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 130mph (3-second gust); h=20ft; TCDL=4.2psf; BCDL=3.Opsf; Category II; Exp B; enclosed; MWFRS; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60. 3) *This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are 3x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 57 lb uplift at joint 1, 61 lb uplift at joint 3 and 60 lb uplift at joint 4. LOAD CASE(S) Standard e WARNING - Verifg design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, civali yf control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component M iT k° Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in Welk 20/20 software or upon request. PLATE SIZE The first dimension is the width 4. X 4. perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. 0 Cc O U CL O R Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA ICBO BEARING SBCCI Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry, Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 96-31, 95-43, 96-20-1, 96-67, 84-32 4922, 5243, 5363, 3907 9667, 9730, 9604B, 9511, 9432A 0 TEE-LOK AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building 0 designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. o_ 5. Place plates on each face of truss at each joint and embed fully Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice Is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Mitee Job Truss Truss Type Oty Ply Centex Homes, Model 2029'B' X06-016 F01 FLOOR 4 1 Job Reference o )net) 6 Universal Forest Product, Inc. E359. FL Pierce, Fl. 34946. James L. Shoaf 6.500 s Feb 5 2007 Ivi rek Industries, Inc. Thu Apr 05 07:21:52 2007 Page 1 0-4-8 .4, f �I H 1�0� o�4i� 2-0-0 1, 1-2, 2-0 0 -7 ()121le= 1:46. t _ I - i i 46 = 46 = I 3x5 II 5x5 = 1.5x4 II 3x6 FP= 46 = 4x6 II 1 2 3 4 6 7 8 9 10 11 12 1 14 15 16 17 5 W 3 3 W 3 W 3 W 3 W 3 W W 3 W Io 1 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 .I 1.50 II 1.5x4 11 4x6 = 3x6 FP= 4x6 = 1.5x4 II 1.5x4 II 4x6 = 1.5x4 II 6x5 = 3x7 = 4x6 = I ' 1-5-0 0-0-0 1-5-0 22-4-2 0018 4-9-0 5-9-0,6-9-01 11-6-0 204-2 21-4-2 26-11-8 24 4-0 i 0-4-8 4-4-8 1-0-0 1-0-0 4-9-0 8-10-2 1-0-0 1-0-0 4-7-6 0-4-8 Plate Offsets X 1:0-3-0;Ed , 4:0-1-8 E e 13:0-1-8 Ed e , 14:0-1.8,Ed e , 17:0-3-0Ede 29:0-1.8,E e ,[33:Edcte.0-0-121 LOADING (psf) SPACING 2-0.0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP . TCLL 40.0 Plates Increase 1.00 TC 0.68 Vert(LL) -0.12 22-23 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.81 Vert(TL) -0.18 22-23 >999 240 BCLL 0.0 Rep Strew Incr YES WB 0.21 Horz(TL) -0.03 26 Na nda BCDL 5.0 Code FBC20G4/TP12002 (Matrix) Weight: 153 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc purlins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (Ib/size) 1=431/0-0-0, 17=719/0-0-0, 26=1761/0.8.0 Max Gravl=533(LC 2), 17=744(LC 4), 26=1761(LC 1) FORCES (lb) - Maximum CompressiordMaximum Tension TOP CHORD 1-33=0/5, 17-18=0/4, 1-2=370/5, 2-3=365/5, 3.4=796/129, 4-5=-808/232, 5-6=-808(232, 6-7=-354/625, 7-8=0/1376, 8-9=0/1376, 9-10=326/121, 10-11=-326/121, 11-12=1179/0, 12-13=1573/0, 13-14=1566/0, 14-15=1332/0, 15-16=-545/0,16-17=-550/0 BOT CHORD 32-33=010, 31-32=-25/682, 30-31=232/808, 29-30=232/808, 28-29=-413/674, 27-28=�17/30, 26-27=-817/30, 25-26=554/0, 24-25=0/854, 23-24=0/1491, 22-23=0/1566, 21-22=011566, 20-21=0/1566, 19-20=0/1017,18-19=0/0 WEBS 4-30=-385/0, 5-29=396/0, 8-26=90/0, 13-22=191/52, 14-21=-39/299, 1-32= 8/550, 3-32=-503/31, 3-31=-165/181, 4-31=-44/385, 7-26=97210, 7-28=0/639, 6.28=-679/0, 6-29=01645, 9-26=1235/0, 9-25=0/915, 11-25=-886/0, 11-24=0/562, 12-24=537/0, 12-23=0/260, 13-23=-255/70, 17-19=0/821, 15-19=750/0, 15-20=0/500, 14-20=584/0 NOTES 1) Unbalanced floor live loads have been considered for this design. ` 2) Al plates are 3x4 MT20 uNess otherwise indicated. 3) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 10 and 27. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, 0 Design valid for use only with MTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component M iTe Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 0 O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside a edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING BEARING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ,.Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A c e Mmk AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on Inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all 0 other interested parties. O U 4. Cut members to bear tightly against each other. O_ 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10, Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. ' Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job Truss Truss Type City Ply Centex Homes, Model 2029'9 X06-016 F02 FLOOR 1 1 Job Reference (optional) Universal Forest Product, Inc. E359, FL Pierce, FI. 34946. James L Shoaf 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:53 2007 Page 1 0-4-8 OAP 1� Qr� 2�) D i 7�6 O6r4d8 F- I le = 1:46. I 4x6 = i 3x5 II 5x5 = 46 = 3x6 FP= 1.5x4 II 4x6 = 3x5 II 1 2 3 4 6 7 8 9 10 11 12 13, 14 15 16 17 5 W 3 W1 2 W 3 W 3 W 3 W 3 W W 3 W I� 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 1.5x4 II 1.5x4 II 1.5x4 II 46 = 3x6 = 3x6 FP= 1.5x4 11 1.5x4 II 5x5 = 4x6 = 4x6 = 1-5-0 0-0-0 22-4-2 1-5-0 Or418 4-9-0 ,5-9-016-9-0, 13-2-0 i 20-4-2 21-4 2 26-11-8 27,1-0 0-4-8 4-4-8 1-0-01-0-0 6-5-0 7-2-2 1-0-01-0-0 4-7-6 0-4-8 Plate Offsets X 1:0-3-0Ed e, 4:0-1$,E e, 5:0-1-8,Ed e, 14:0-1-8,Ed e, 17:0-3-0,Ed a 19:0-1-12Ed e, 22:0-1-8,Ed e, 33:Ed e.0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (too) I/detl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.48 Vert(LL) -0.06 22-23 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.53 Vert(TL) -0.08 22-23 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.19 Horz(TL) -0.02 26 nla Na BCDL 5.0 Code FBC2004/TP12002 (Matrix) Weight: 153 lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purfins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 104)-0 oc bracing, Except: WEBS 4 X 2 SYP No.2 6-0-0 oc bracing: 27-28,26-27,25-26,23-25. REACTIONS (Ib/size) 1=542/04-0, 17=608/0-0-0, 26=1761/0-0-15 Max Gravl=603(LC 2), 17=658(LC 3), 26=1761(LC 1) FORCES (lb) - Maximum CompressioNMaximum Tension TOP CHORD 1-33=0/5, 17-18=0/5, 1-2=-428/0, 2-3=-424/0, 3-4=-980/0, 4-5=-1054/0, 5-6= 894/135, 6.7=-292/428, 7-8=0/1372, 8-9=0/1372, 9-10=011372, 10-11=324/364, 11-12=1016R% 12-13=124810,13-14=1248/0, 14-15=-1112/0, 15-16=47210,16-17=-476/0 BOT CHORD 32-33=0/0, 31-32=0f792, 30-31=0/1054, 29-30=0/1054, 28-29=0/1054, 27-28=-268f701, 26-27=708/0, 25-26=-661/0, 24-25=-198f/78, 23-24=198f778, 22-23=0/1225, 21-22=0/1248, 20-21=0/1248, 19-20=0/882, 18-19=0/0 WEBS 4-30=-259f75, 5-29=19/153, 8-26=-102/0, 13-22=280/0, 14-21=135/85, 1-32=0/638, 3.32=-58510, 3-31=-40/298, 4-31=-272/176, 7-26=-1075/0, 7-27=01763, 6-27=-730/0, 6-28=01409, 5-28=-060/0, 10-26=1131/0, 10-25=0/825, 11-25=794/0, 11-23=0/448,12-23=426/0, 12-22=01419, 17-19=0f7l l,15-19=-652J0, 15-20=0/365, 14-20=339/71 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 24 and 9. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - Ver!N design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional -permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component ° Safety InfoFination available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property -Ilij3/q *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal • and securely seat. or X-bracing, is always required, See BCSI1. 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack 01-2 c2-3 materials on inadequately braced trusses. WEBS 3. Provide copies of this truss design to the building oT7 designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate A,,4 W wother 0 ,,, �30 interested arties. p0plates 0 - /ie" from outside a0 U4. Cut members to bear tightly against each other. edge of truss. a5. Place plates on each face of truss at each joint and c7-e csa embed fully. Knots and wane at joint locations are BOTTOM CHORDS _ *This symbol indicates the regulated by ANSI/TPI1. required direction of slots in 8 7 6 5 6, Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate Iodation details available in MiTek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width - NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 44 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12. Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. �Su (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior Lie reaction section Indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTeko DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, ■s ILI Installing & Bracing of Metal Plate © 2004 Mitek® Connected Wood Trusses. Job Truss Truss Type Oty Ply Centex Homes, Model 2029'B' X06-016 F03 FLOOR 1 1 Job Reference o 6onal Universal Forest Product, Inc. E359, FL Pierce, R:34946. James L. Shoaf 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:54 2007 Page 1 04-8 1-3-0 8 01 l= 1:46. e i yj 3x7 II 5x5 = 46 = 3x6 FP= 1.5x4 II 4x6 = 3x5 II 1 2 3 4 5 34, 6 7 8 9 10 11 12 13 3514 15 16 17 I 1 5 W 1 1 W 1 ny� V 1 W 7 W 1 yy I� 33 32 31 30 29 28 - 27 26 25 24 23 22 21 20 19 18 1.5x4 11 4x6 = 1.6x4 II 1.5x4 11 3x6 FP = 4x6 = 3x7 = 1.5x4 11 1.5x4 11 5x5 = 4x6 = I - 0-0-0 1-5-0 1-5-0 22-4-2 0018 4-9-0 15-9-016-9-0, 15-2-0 i 204-2 214-2 26-11-8 27,-4-0 04-8 44-8 1-0-01-0-0 8-5-0 5-2-2 1-0-0 1-0-0 4-7-6 0-4-8 Plate Offsets X, 4:0-1-8f 5:0-1-8,Ed e , 14:0-1-8 Ed 17:0-3-0,Ed e , 22:0-1-8,Ed e , 33:Ed e,0-0-12 LOADING (psf) SPACING 2-" CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.59 Vert(LL) -0.11 28-29 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.75 Vert(TL) -0.15 28-29 >999 240 BCLL 0.0 Rep Stress Ina YES WB 0.20 Horz(TL) -q.02 17 n/a nla BCDL 5.0 Code FBC2004rrP.12002 (Matra) Weight:153 Ito LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0.0 oc pudins, except end verticals. BOT CHORD 4 X 2 SYP Not BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 4X2SYP No.2 REACTIONS (lb/size) 1=682/0.4-0, 17=484/04-0, 24=1744/04-15 Max Grav1=714(LC 7), 17=570(LC 3). 24=1744(LC 1) FORCES (lb) - Maximum CompressiordMaximum Tension TOP CHORD 1-33=0/4,17-18=0/6, 1-2=522/0, 2-3=-517/0, 3-4=127210, 4-5=1434/0, 5-34=-1471/0, 6.34=1471/0, 6-7=114110, 7-8=360/162, B-9=0/1340, 9-10=0/1340, 10-11=011340. 11-12=383/546, 12-13=-929/142, 13-35=929/142, 14-35=929/142, 14-15=883/41, 15-16=397/0, 16-17=-00710 BOT CHORD 32-33=010, 31-32=01969, 3031=011434, 29-30=011434, 28-29=0/1434, 27-28=0/1411, 26-27=7/855, 25-26=-7/855, 24-25=549/0, 23-24=728/30, 22-23=355f726, 21-22=142/929, 20-21=-142/929,19-20=0/743, 18-19=0/0 WEBS 4-30=67/340, 5-29=224/66, 9-24=91/0, 13-22=-311/0, 14-21=265/0, 1-32=0f779, 3-32=-717/0, 3-31=0/482, 4-31=-595/0, 8-24=-1188/0, 8-25=0/874, 7-25=-845/0, 7-27=0/511, 6-27=-483! , 6-28=0/263, 5-28=245/122, 11-24=-999/0, 11-23=0/662, 12-23=-682/0, 12-22=0/599,17-19=0/598, 15-19=550/0, 15-20=108I221, 14-20=-116/252 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) The following joint(s) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 10 and 26. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard _ A WARNING - Ver(N design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of bullding designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication,-qualiiy control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB 89 and BCSIi Building Component Safety Infoimatlon available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. NI iTe Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. X O * For 4 x 2 orientation, locate plates 0 - 1/16" from outside edge of truss. a OR *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT The first dimension is the width NUMBERS/LETTERS. 4. X 4. perpendicular to slots. Second dimension is the length parallel to slots. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. ICBO 4922, 5243, 5363, 3907 BEARING'. SBCCI 9667, 9730, 9604B, 9511, 9432A Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. MiTek° DSB-89: Design Standard for Bracing, BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, ■ / Installing & Bracing of Metal Plate Connected Wood Trusses. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building ❑ designer, erection supervisor, property owner and all p� other interested parties. O U 4. Cut members to bear tightly against each other. EL 5. Place plates on each face of truss at each joint and OR embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber Is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 Wek" Job JobX06 Truss Truss Type Oty Ply Centex Homes, Model 2029'B' F04 FLOOR 7 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, Fl. 34946. James L Shoaf 6.500 s Feb 5 2007 MTek Industries, Inc. Thu Apr 05 07:21:54 2007 Page 1 0-4-8 Hi 0t 1 F 1�8� 4 9�f1 2�0� 7�6 0r4,8 s le= t:as. i 4x6 = 4x6 = 4x6 II 5x5 = 3x6 FP= ISM II 4x6 = 3x5 II 1 2 3 4 34 6 7 8 9 10 11 12 1 3614 15 16 17 S W 3 2 W 3 W 3 W 3 V W 3 W Vil W 3 W 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 1.5x4 11 4x6 = 1.5x4 II 1.5x4 11 3x6 FP= 4x6 = 3x7 = 4x6 = 1.5x4 11 1.5x4 11 5x5 = 4x6 = I 1 I 1-5-0 0-0-0 1-5 0 22-4-2 I 01418 4-9-0 5-9-016-9-01 1 5-6-8 20-4-2 214-2 26-11-8 241-0 0-4-8 4-4-8 1-0-01-0-0 8-9-8 4-9-10 1-0-01-0-0 4-7-6 04-8 Plate Offsets X. 1:0-3-0E e 4:0.1-8,Ed e , 5:0-1-8,Ed e , 14:0-1-8,Ed e , 17:0-3-0,Ed e , 22:0-1.8,Ed e , 33:Ed e,0-0-12 LOADING (psf) SPACING 2-M CSI DEFL in (loc) Ildefl Ud PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.69 Vert(LL) -0.12 28-29 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.85 Vert(TL) -0.18 28-29 >999 240 BCLL 0.0 Rep Stress Inor YES WB 0.21 Horz(TL) -0.02 17 Na n/a BCDL 5.0 Code FBC2004/TPI2002-.. (Matrix) Weight: 153 lb LUMBER BRACING '. TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0.0 oc pudins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc tracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 1=704/04-0,17=456/0-", 24=175110-3-8 Max Grav1=730(LC 7), 17=554(LC 3), 24=1751(LC 1) FORCES (lb) - Maximum CompressionfMaximum Tension TOP CHORD 1-33=0/4, 17-18=0/7, 1-2=536/0, 2-3=531/0, 3-4=131510, 4-5---1496/0, 5-34=1524/0, 6-34=1524/0, 6-7=115910. 7-8=-3361112, 8-9=336/112, 9-10=0/1362, 10-11 =0/1 362. 11-12=390/607,12-13=-872/212, 13-35=-8721212, 35-36=872/212, 14-36=-8721212, 14-15=-841/93, 15-16=384/0, 16-17=-388I0 BOT CHORD 32-33=0/0, 31-32=01994, 30-31=0/1496, 29-30=0/1496, 28-29=0/1496, 27-28=0/1456, 26-27=0/848, 25-26=0/848, 24-25=553/0, 23.24=796/58, 22-23=3981721, 21-22=212/872, 20-21=-212/872, 19-20=5/718, 18-19=0/0 WEBS 4-30=-34/404, 5-29=203/38, 10-24=90/0, 13-22=389/0, 14-21=-289/0,1-32=0/800, 3-32=735/0, 3-31=0/511, 4-31=-67510, 9-24=1215/0, 9-25=0/896, 7-25=-867/0, 7-27=0/543, 6-27=-517/0, 6-28=0Y246, 5-28=228/92, 11-24=980/0, 11-23=0/646, 12-23=-687/0, 12-22=0/649, 17-19=0/578, 15-19=531/14, 15-20=-141/195, 14-20=78/297 NOTES '1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) The following joints) require plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection: 26 and 8. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - VerWfy design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE, 14515 N. Outer Forty, Design valld for use only with Mrrek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Appilcability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of indiyidual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Mel Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI.53719. Symbols Numbering System AGeneral Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property 13/14 *Center plate on joint unless x,y Damage or Personal Injury offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1. Additional stability bracing for truss system, e.g. diagonal and securely seat. or X-bracing, is always required. See BCSII . 1 2 3 TOP CHORDS 2. Never exceed the design loading shown and never stack c,-x cza materials on inadequately braced trusses. WEBS c3 4 3. Provide copies of this truss design to the building cc designer, erection supervisor, property owner and all *For 4 x 2 orientation, locate �,� ��' 3 X other interested parties. plates 0 -/ib" from outside truss. O O y1a6 "a U OR 4. Cut members to bear tightly against each other. edge of 5. Place plates on each face of truss at each joint and c7-e csa cs-s OR embed fully. Knots and wane at joint locations are BOTTOM CHORDS *This symbol indicates the regulated by ANSI/TPI1. ' required direction of slots in 8 7 6 5 6, Design assumes trusses will be suitably protected from connector plates. the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall * Plate location details available in MITek 20/20 not exceed 19% at time of fabrication. software or upon request. JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 8. Unless expressly noted, this design is not applicable for THE LEFT. use with fire retardant or preservative treated lumber. PLATE SIZE CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 9. Camber is a non-structural consideration and is the The first dimension is the width NUMBERS/LETTERS. responsibility of truss fabricator. General practice 4 x 4 perpendicular to slots. Second is to camber for dead load deflection. dimension is the length parallel 10. Plate type, size, orientation and location dimensions to slots. CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. LATERAL BRACING 11. Lumber used shall be of the species and size, and in all Indicated by symbol shown and/or BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. by text in the bracing section of the 12, Top chords must be sheathed or purlins provided at output. Use T, I or Eliminator bracing spacing shown on design. if indicated. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ff. spacing, BEARING SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. Indicates location where bearings 14. Connections not shown are the responsibility of others. (supports) occur. Icons vary but 15. Do not cut or alter truss member or plate without prior reaction section indicates joint approval of a professional engineer. number where bearings occur. 16. Install and load vertically unless indicated otherwise. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. M iTek° DSB-89: - 'Design Standard for Bracing. BCSII : Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate © 2004 WOO Connected Wood Trusses, Job Truss Truss Type Qty Ply Centex Homes, Model 2029'B' X06-016 F05 FLOOR 3 1 Job Reference o fional Universal Forest Product, Inc. E359, FL Pierce, FI. 34946, James L. Shoal 6.500 s Feb 5 2007 MTek Industries, Inc. Thu Apr 05 07:21:55 2007 Page 1 0-4-8 1-3-0 Q 4- , 2-0-0 0-9-4 Scale =1:25. i - i 4x6 II 5x5 = 1.5x4 II 46 = 1 2 3- 4 5 6 7 8 9 i 2 W 3 V i 3 W 3 W 3 W i 18 17 16 15 14 13 12 11 1.5x4 11 4x6 = 2x3 II 4x6 = 5x5 I I 1-5-0 0-0-0 94-$ 4-9-0 5-9-0 6-9-0 154-12 0 4 8 44-8 1-0-0 1-0-0 8-7-12 Plate Offsets X 1:0-3-0Ed e , 3:0-1-12,Ed e , 4:0-1.8,Ed e , 10:Ed e,0-1-8, 14:0.1.8,Ed e , 15:0-1-8,Ed e , 18:Ed e,0-0.12 LOADING (psf) SPACING 2-0-0 CS1 DEFL in (loc) I/deft IJd PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.77 Vert(LL) -0.18 13-14 >998 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.97 Vert(TL) -0.2713-14 \>659 240 BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(TL) 0.03 10 Na rda BCDL 5.0 Code FBC2004/TPI2002 (Matrix) Weight: 88lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD 4 X 2 SYP No.1 BOT CHORD Rigid ceiling directly applied or 10-M 0o bracing, Except: WEBS 4 X 2 SYP No.2 2-2-0 oc bracing: 15-16,14-15. REACTIONS (lb/size) 10=816/0-3-8, 1=816/0-4-0 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-18=0/3, 9-10=-81210, 1-2=-607/0, 2-3=-602/0, 3-0=-1545/0, 4-5=1786/0, 5-6=-1786/0, 6.7=-1921/0, 7-8=-1498/0, 8-9=-630/0 BOT CHORD 17-18=0/0, 16-17=0/1129,15-16=0/1786,14-15=0/1786,13.14=0/1956,12-13=0/1805,11-12=0/1182,10.11=0/0 WEBS 4-15=0/580, 5-14=-95/208, 1-17=0/907, 3-17=837/0, 3-16=0/687, 4-16=983/0, 9-11=0/947, 8-11=-877/0, 8-12=0/500, 7-12=-489/0, 7-13=0/198, 6.13=152/24, 6-14=-069197 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 3x4 MT20 unless otherwise indicated. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - Ver jy destgn parameters and READ NOTES ON TffiS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an individual building component. Suite #300 Applicability of design parameters and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication,qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component ° Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside a edge of truss. OR *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction: DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII . 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. EL 5. Place plates on each face of truss at each joint and 0 embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI I. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted, 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise, © 2004 Mitek® Job Type Oty PlyTjob tex Homes, Model 2029'B' X06-016 TICU6 ]FLOOR 3 Reference o tional Universal Forest Product, Inc. E359. Ft Pierce, Fl. 34946, James L. Shoat 6.500 s Feb 5 2007 MiTek Industries, Inc. Thu Apr 05 07:21:55 2007 Page 1 0-4-8 F—i ,�� 0-7-0 2-0-0 �0-6-14 � �--i scale = 1:19. 3x5 II 3x4 = 3x4 = 4x6 = 30 = 36 = 1 2 3 4 16 17 5 06 = 6 7 N'V 2 W 3 4 6 W 3 W 15 14 13 12 11 10 9 1.50 11 3x4 = 4x6 = 1.5x4 11 1.5x4 11 46 = 3x4 = 3x4 11 1-5-0 0-0-0 p-4-1 4-11-14 i 5-11-14 , 6-11-14 11-8-4 0A-8 4-7-6 1-0-0 1-0-0 4-8-6 Plate Offsets X 1:0-3-0.E a 4:0-1-8 Ed e . 5:0-1-8.Ed e , :0-2-0Ed e . 15:Ed e,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.33 Vert(LL) -0.04 11 >999 480 MT20 244/190 TCDL 10.0 Lumber Increase 1.00 BC 0.43 Vert(TL) -0.06 11 >999 240 BCLL 0.0 Rep Stress Inor YES WB 0.15 Horz(TL) 0.01 8 n/a n/a BCDL 5.0 Code FBC20041TP12002 - (Matrix) Weight: 68lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD 4 X 2 SYP N0.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 8=612/0-3-8, 1=6121DA-0 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-15=0/5, 7-8=-607/0, 1-2=-437/0, 2-3=-433/0, 3-4=99210, 4-16=108210, 16-17=1082/0, 5-17=1082/0, 5-6=100210, 6-7=-045/0 BOT CHORD 14-15=0/0, 13.14=0/809, 12-13=0/1082, 11-12=0/1082, 10-11=0/1082, 9-10=0/832, 8-9=0/0 WEBS 4-12=-118/137, 5-11=121/145, 1-14=01652, 3-14=598/0, 7-s=0/669, 6-9-614/0, 6.10=0/323, 5-10=348/0, 3-13=0/330, 4-13=350/0 NOTES 1) Unbalanced floor live loads have been considered for this design. 2) Recommend 2x6 sbongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. 14515 N. Outer Forty, O Design valid for use only with Mlrek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Suite #300 Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not truss designer. Bracing shown Chesterfield, MO 63017 Is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication,_ quality control, storage, delivery, erection and bracing, consult ANSI/TPI1 Quality Criteria, DSB-89 and BCSII Building Component MiTel O Safety Information available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 53719. 1 Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and securely seat. For 4 x 2 orientation, locate plates 0 -'/16" from outside edge of truss. *This symbol indicates the _ required direction of slots in connector plates. * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur, Industry Standards: ANSI/TPI1:• National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: ,:Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSII . 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other Interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions CONNECTOR PLATE CODE APPROVALS shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all BOLA 96-31, 95-43, 96-20-1, 96-67, 84-32 respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 4922, 5243, 5363, 3907 13. Bottom chords require lateral bracing at 10 ft. spacing, SBCCI 9667, 9730, 9604B, 9511, 9432A or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise, El MiTek® © 2004 Mitek® Job Truss Truss Type Oty Ply Centex Homes, Model 2029'13' X06-016 F07 FLOOR 2 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, FI. 34946, James L. Shoat 6.300 s Dec 1 2005 MiTek Industries, Inc: Mon Apr 1610:07:03 2007 Page 1 0-4-0 2-6-0 1-9-8 Scale=1:12. • 4x6 II 3x4 = - 1 2 3 2x3 11 4 3x4 = 5 3x4 II 12 yr4 W5 1 W2 2x3 11 3x5 = 6 8 7 3x5 = 1-5-0 0-0-0 0-4-0 7-7-8 04-0 7-3-8 Plate Offsets X 1:0-3-0,Ed e , 6:0-2-0,Ed e LOADING (psf) TCLL 40.0 SPACING 2-0-0 Plates Increase 1.00 CSI TC 0.30 DEFL in (loc) Well L/d Vert(LL) -0.01 7 >999 480 PLATES GRIP MT20 244/190 TCDL 10.0 BCLL 0.0 BCDL 5.0 Lumber Increase 1.00 Rep Stress Incr YES Code FBC20041TP12002 BC 0.17 WB 0.12 (Matrix) Vert(TL) -0.05 6-7 >999 240 Hort(TL) Q00 6 Na Na Weight'. 45 Ito LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6*-0 oc purlins, except end verticals. BOT CHORD 4 X 2 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 6=391/0-1-8, 1=391/0-3-8 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-8=017, 5-6=71/0, 1-2=-475/0, 2-3=-470/0, 3-4=-470/0, 4-5=0/0 BOT CHORD 7-8=0/0, 6-7=0/374 WEBS 1-7=0/540, 3-7=-277/0, 4-7=0/112, 4-6=-081/0 NOTES 1) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6.. 2) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 3) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 4) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard A WARNING - Ver fN design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication, qualify control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI1 Building Component ° Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. M iTe Symbols PLATE LOCATION AND ORIENTATION -01 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. O * For 4 x 2 orientation, locate v plates 0 - 1/16" from outside edge of truss. *This symbol indicates the required direction of slots in connector plates. * Plate location details available in MITek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4. perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING Indicated by symbol shown and/or by text in the bracing section of the output. Use T, I or Eliminator bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: - Design Standard for Bracing. BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 2 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS BOCA 96-31, 95-43, 96-20-1, 96-67, 84-32 ICBO 4922, 5243, 5363, 3907 SBCCI 9667, 9730, 9604B, 9511, 9432A AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building o designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. °- 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPII , 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and In all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV Job Truss Truss Type Qty Ply Centex Homes, Model 2029'B' X06-016 F08 FLOOR 2 1 Job Reference (optional) Universal Forest Product, Inc. E359, Ft. Pierce, F1. 34946. James L. Shoat 6.500 s Feb 5 2007 MTek Industries, Inc. Thu Apr 05 07:21:56, 2007 Page 1 0-4-8 r 1-3-0 1-3-8 3x5 II 3x4 = 5 = Scale= 1:10. • 1 2 3 3A = 4 ud W 3 W V2 4 W5 W5 Wt 1.5x4 11 3x4 = 3x4 = 8 7 6 1-5-0 UPIP-0 0-4-8 5-9-8 � r 04-8 5-5-0 Plate Offsets X, 1:03-0,Ed e , 4:0-2-0,Ed e , 8:Ed e,0-0-12 LOADING (psf) SPACING 24)-0 CS! DEFL in (too) Udell L/d PLATES GRIP TCLL 40.0 Plates Increase 1.00 TC 0.37 Vert(LL) -0.00 7 >999 480 MT20 2441190 TCDL 10.0 Lumber Increase 1.00 BC 0.08 Vert(TL) -0.01 6-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.06 Horz(TL) 0.00 5 Na n/a BCDL 5.0 Code FBC2004/TPI2002 (Matrix) _ Weight: 36lb LUMBER BRACING TOP CHORD 4 X 2 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 5-9-8 oc pudins, except end verticals. BOT CHORD 4 X 2 SYP N0.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 4 X 2 SYP No.2 REACTIONS (lb/size) 5=28810-3-8,1=288104-0 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-8=0/3, 4-5=283/0, 1-2=-166/0, 2-3=-162/0, 3-4=-164/0 BOT CHORD 7-8=0/0, 6-7=0/291, 5-6=0/0 WEBS 1-7=0/244, 3.7=-206/0, 3-6=-202/0, 4-6=0/243 NOTES 1) Recommend 2x6 strongbacks, on edge, spaced at 10-M oc and fastened to each truss with 3-16d nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 3) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard ' n, A WARNING - Ver!N design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE. Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an Individual building component. Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 RiT Is for lateral support of Individual web members only.Additional temporary bracing to Insure stability during construction Is the responsibility of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding fabrication,qualif�control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSII Building Component Safety Information available from Truss Plate Institute, 583 D'Onofrio Drive, Madison, WI 53719. k® Symbols PLATE LOCATION AND ORIENTATION 13/4 *Center plate on joint unless x,y offsets are indicated. Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss and securely seat. 0 M O * For 4 x 2 orientation, locate plates 0 -/ie" from outside o edge of truss. O. *This symbol indicates the required direction of slots in connector plates, * Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the width 4 X 4 perpendicular to slots. Second dimension is the length parallel to slots, Numbering System 6-4-8 dimensions shown in ft-in-sixteenths 1 2 3 TOP CHORDS BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. CONNECTOR PLATE CODE APPROVALS LATERAL BRACING Indicated by symbol shown and/or BOCA by text in the bracing section of the output. Use T, I or Eliminator bracing If indicated. ICBO SBCCI BEARING Indicates location where bearings (supports) occur. Icons vary but IiF reaction section indicates joint number where bearings occur. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI1: Building Component Safety Information, .Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 96-31, 95-43, 96-20-1, 96-67, 84-32 4922, 5243, 5363, 3907 9667, 9730, 9604B, 9511, 9432A TEf =LOK- ��A3 ■ �C5&4 AGeneral Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury I . Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1. 2. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 3. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. O U 4. Cut members to bear tightly against each other. 5. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI1. 6. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI1. 7. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 8. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 9. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 10. Plate type, size, orientation and location dimensions shown indicate minimum plating requirements. 11. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 12. Top chords must be sheathed or purlins provided at spacing shown on design. 13. Bottom chords require lateral bracing at 10 ff, spacing, or less, if no ceiling is installed, unless otherwise noted. 14. Connections not shown are the responsibility of others. 15. Do not cut or alter truss member or plate without prior approval of a professional engineer. 16. Install and load vertically unless indicated otherwise. © 2004 MiteV