Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS_2E. O. Koch HVAC Load Calculations for Mitch 4808 Barcolona Dr Ft. Pierce FL Imi BVCHVACLOP 1pmexe'e Prepared By: Michael Sullivan Millers Central Air 20 West Interlake Blvd Lake Placid FL (863)699-5455 Friday, July 18, 2008 r � . `%R.M'600A-2004R EnergyGauge® 4.5 FLORIDA ENERGY EFFICIENCY CODE • FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: E.O. Koch -Mitch Builder: E.O. Koch Address: 4808 Barcolona Dr Permitting Office: St Lucie City, State: Ft Pierce, FL Permit Number: Owner: Mitch Jurisdiction Number: 661100 Climate Zone: Central f New construction or existing New _ 2. Single family or multi -family Single family _ 3. Number of units, if multi -family 1 4. Number of Bedrooms 3 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ft2) 1120 ft2 _ 7. Glass type and area: (Label reqd. by 13-104.4.5 ifnot default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 71.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 7b. (SC=0.45) 71.0 ft2 8. Floortypes a. Slab -On -Grade Edge Insulation R-0.0, 132.0(p) ft _ b. N/A _ c. N/A _ 9. Wall types a. Concrete, hit hisul, Exterior R=11.0, 935.0 ft2 _ b. N/A _ c. N/A _ d. N/A _ e. N/A _ 10. Ceiling types _ a. Under Attic R=30.011120.0 ft2 b. N/A c. N/A _ 11. Ducts _ a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 25.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Strip b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, BF -Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.06 Total as -built points: 14395 PASS Total base points: 16495 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: lZ . A�_-_ DATE: n I z% \ dQ I hereby certify that this building, as designed, is in compliance with the Florida Energy C OWNER/AGENT- DATE: Cap: 22.0 kBtu/hr SEER: 13.00 Cap: 5.0 kBtu/hr COP: 1.00 Cap: 50.0 gallons EF: 0.97 PT, CF, Review of the plans and Tui ST specifications covered by this o� _ �9T�0 calculation indicates compliance with the Florida Energy Code. Before construction is completed o this building will be inspected for c� a compliance with Section 553.908 Florida Statutes. f'I'coD1y5� BUILDING OFFICIAL: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCSB v4.5) r� -FORM' 600A-2004R EnergyGauge® 4.5 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 4808 Barcolona Dr, Ft Pierce, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 ` FORM�'600A-2004R EnergyGauge@ 4.5 WATER HEATING & CODE COMPLIANCE STATUS R Residential Whole Building Performance Method A - Details I ADDRESS: 4808 Barcolona Dr, Ft Pierce, FL, PERMIT #: I BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2460.00 7380.0 50.0 0.97 3 1.00 2333.20 1.00 6999.6 As -Built Total: 6999.6 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water = Total Points Points Cooling Points + Heating + Hot Water = Total Points Points Points 6858 2257 7380 16495 3923 3473 7000 14395 PASS EnergyGauge'fm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 ' �OR9'600A-2004R EnergyGauge@ 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 4808 Barcolona Dr, Ft Pierce, FL, PERMIT #: BASE AS -BUILT Winter Base Points: 4073.6 Winter As -Built Points: 3375.9 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Strip 5000 btuh ,EFF(1.0) Ducts: Unc(S),Con(R), Int(AH), R6.0 3375.9 1.000 (1.068 x 1.160 x 0.87)1.000 0.950 3472.6 4073.6 0.5540 2256.8 3375.9 1.00 1.083 1.000 0.950 3472.6 EnergyGauge'rm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 1FORM'600A-2004R EnergyGaugeO 4.5 WINTER CALCULATIONS ` Residential Whole Building Performance Method A - Details I ADDRESS: 4808 Barcolona Dr, Ft Pierce, FL, PERMIT #: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1120.0 9.11 1837.0 1.Single, SC=0.45 N 1.5 5.0 10.0 16.18 1.00 161.0 2.Single, SC=0.45 N 7.5 6.0 13.0 16.18 0.99 207.0 3.Single, SC=0.45 S 1.5 7.0 16.0 13.45 1.03 221.0 4.Single, SC=0.45 S 1.5 8.0 32.0 13.45 1.02 437.0 As -Built Total: 71.0 1026.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Int Insul, Exterior 11.0 935.0 1.50 1402.5 Exterior 935.0 2.00 1870.0 Base Total: 936.0 1870.0 As -Built Total: 935.0 1402.6 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 42.0 5.10 214.2 Exterior 42.0 5.10 214.2 Base Total: 42.0 214.2 As -Built Total: 42.0 214.2 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1120.0 0.64 716.8 1. Under Attic 30.0 1120.0 0.64 X 1.00 716.8 Total: 1120.0 716.8 As -Built Total: 1120.0 716.8 1Base FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points --Slab---- - - - 132.0(p} ---------1:9 - ---2%8 1 Slab-On-Grade-Edge-Insulation------0:0-- 132:0(p ---- 2.50-- - -330.0 Raised 0.0 0.00 0.0 Base Total: -250.8 As -Built Total: 132.0 330.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1120.0 -0.28 -313.6 1120.0 " -0.28 -313.6 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 ' `FORfVI'600A-2004R EnergyGauge@ 4.5 SUMMER CALCULATIONS ' Residential Whole Building Performance Method A - Details ADDRESS: 4808 Barcolona Dr, Ft Pierce, FL, PERMIT #: I BASE AS -BUILT Summer Base Points: 21102.3 Summer As -Built Points: 15759.6 -rotal Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 22000btuh ,SEER/EFF(13.0) Ducts: Unc(S),Con(R),lnt(AH),R6.0(INS) 15760 1.00 (1.08 x 1.150 x 0.85) 0.260 0.902 3923.3 21102.3 0.3250 6858.2 15759.6 1.00 1.061 0.260 0.902 3923.3 EnergyGauge'rm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 'F0R0600A-2004R EnergyGauge® 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 4808 Barcolona Dr, Ft Pierce, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1120.0 24.35 4909.0 1.Single, SC=0.45 N 1.5 5.0 10.0 9.75 0.92 89.0 2.Single, 8C=0.45 N 7.5 6.0 13.0 9.75 0.69 87.0 3.Single, SC=0.45 S 1.5 7.0 16.0 18.28 0.91 265.0 4.Single, SC=0.45 S 1.5 8.0 32.0 18.28 0.93 541.0 As -Built Total: 71.0 982.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Int Insul, Exterior 11.0 935.0 0.40 374.0 Exterior 935.0 1.90 1776.5 Base Total: 935.0 1776.5 As -Built Total: 935.0 374.0 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 42.0 4.80 201.6 Exterior 42.0 4.80 201.6 Base Total: 42.0 201.6 As -Built Total: 42.0 201.6 CEILING TYPES Area X BSPM = Points Type 1 R-Value Area X SPM X SCM = Points Under Attic 1120.0 2.13 2385.E 1. Under Attic 30.0 1120.0 2.13 X 1.00 2385.6 Base Total: 1120.0 2385.6 As -Built Total: 1120.0 2385.6 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points -Slab------- - -----132.0(p)-- ---31.8- -----4197-.6 1-Slab-On-Grade-Edge•Insulation --0.0 --132:0(p- -=31.90-- - -- -4210:8 Raised 0.0 0.00 0.0 Base Total: -4197.6 As -Built Total: 132.0 -4210.8 INFILTRATION Area X BSPM = Points Area X SPM = Points 1120.0 14.31 16027.2 1120.0 14.31 16027.2 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 r ENERGY PERFORMANCE LEVEL (EPL) ' DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 88.4 The higher the score, the more efficient the home. Mitch, 4808 Barcolona Dr, Ft Pierce, FL, k. New construction or existing New 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 4. Number of Bedrooms 3 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ft2) 1120 ft2 7. Glass type and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 71.0 ft2 _ b. SHGC: (or Clear or Tint DEFAULT) 7b. (SC=0.45) 71.0 ft2 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 132.0(p) ft b. N/A _ - c. N/A _ 9. Wall types a. Concrete, Int Insul, Exterior R=11.0, 935.0 ft2 b. N/A _ c. N/A _ d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic R=30.0, 1120.0 ft2 b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 25.0 ft _ b. N/A _ 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Strip b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. r Builder Signature: Cc- - JA"�' Date: Iz T1) vW Address of New Home: City/FL Zip: Cap: 22.0 kBtu/hr SEER: 13.00 Cap: 5.0 kBtu/hr _ COP: 1.00 Cap: 50.0 gallons EF: 0.97 PT, CF, *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarlmdesignation), your home may qualify for energy efficiency mortgage (EE" incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf. edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areas see Summer & Winter Glass outpAut on ages 2&4. NergyGauge® (Version: FLR Pv4.5) Rhvac - Residential & Light Commercial HVAC Loads Elite Software Develo ment, inc.g P Miller's Central Air E.O. Koch Lake Placid FL 33852 Page 2 Project Report Project Filename: Project Title: Project Date: Client Name: Client Address: Client City: Company Name: Company Representative: Company Address: Company City: Company Phone: E.O. Koch Thursday, July 17, 2008 Mitch 4808 Barcolona Dr Ft. Pierce FL Millers Central Air Michael Sullivan 20 West Interlake Blvd Lake Placid FL (863)699-5455 . rhv I Design Data Reference City: Fort Pierce, Florida Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: 42 0 0 72 0 Summer: 90 78 50 75 61 Check Figures Total Building Supply CFM: 706 (4.7 AC/hr) CFM Per Square ft.: 0.630 Square ft. of Room Area: 1,120 Square ft. Per Ton: 650 Building Loads Total Heating Required With Outside Air: 11,648 Btuh 11.648 MBH Total Sensible Gain: 15,518 Btuh 75 % Total Latent Gain: 5,140 Btuh 25 % Total Cooling Required With Outside Air: 20,658 Btuh 1.72 Tons (Based On Sensible + Latent) 1.72 Tons (Based On 75% Sensible Capacity) Notes Calculations-are-based-on-7th-edition-of-ALGA Manual-J. - -- -- - — - All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Miller's Central Air & E.O. Koch Lake Placid, FL 33852 Page 3 Miscellaneous Report System 1 Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Humidity Dry Bulb Difference Winter: 42 0 _ 50 72-110.11 Summer: 90 78 50 75 61.09 Duct Sizing Inputs Main Trunk Runouts .Calculate: Calculate: Yes Yes Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration: 0.400 AC/hr 0.200 AC/hr Volume of Conditioned Space: X 8960 Cu.ft. X 8960 Cu.ft. 3,584 Cu.ft./hr 1,792 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 60 CFM 30 CFM Total Building Ventilation: 0 CFM 0 CFM --System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac - Residential & Light Commercial HVAC Loads Miller's Central Air N Elite Software Development, Inc. E.O. Koch Lake Placid, FL 33852 Page 4 Load Preview Report Sens Lat Net Sens Win Sum Adj Sys Duct Scope Area Gain Gain Gain Loss CFM CFM CFM CFM Size Building: _1,72 Net Tons, 1.72 Recommended Tons, 650 ft.Z/Ton, 11.65 MBH Heating Building 1,120 15,518 5,140 20,658 11,648 151 706 706 System 1: 1.72 Net Tons, 1..72 Recommended Tons, 650 ft.Z/Ton, 11.65 MBH Heating System 1 1,120 15,518 5,140 20,658 11,648 151 706 706 10x12 Zone 1 1,120 15,518 5,140 20,658 11,648 151 706 706 1-Kitchen, Dining, Living Room 590 9,725 4,613 14,338 5,844 76 442 442 442 5-6 2-Bedroom 3 143 1,580 176 1,756 1,408 18 72 85 72 1-5 3-Master Bedoom 175 2,290 351 2,641 2,912 38 104 141 104 1-6 4-Bedroom 3, Bathroom 212 1,924 0 1,924 1,484 19 88 88 88 1-5 C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac - Residential & Light Commercial HVAC Loads Miller's Central Air Elite Software Development, Inc. E.O. Koch Lake Placid, FL 33852 owl, Pa e 5 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 1C Window Clear Glass Metal Frame 71 2,459 0 1,278 1,278 11A Door Metal Fiberglass Core 42 744 0 460 460 14C Wall 8" or 12" Block + R-11 935 2,159 0 813 813 16G Ceiling Under Vent. Attic - R-30 Insulation 1120 1,109 0 1;441 1,441 22A Slab on Grade No Edge Insulation _ 132 3,207 _ _ 0 0 _ 0 Subtotals for structure: 9,678 0 3,992 3,992 People: 6 1,380 1,800 3,180 Equipment: 2,520 590 3,110 Lighting: 2535 8,644 8,644 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 60, Summer CFM: 30 1,970 1,240 492 1,732 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Sensible Gain Total: 15,518 Temperature Swing Multiplier: _ _ X 1.00 _ Total Building Load Totals: 11,648 5,140 15,518 20,658 Check Figures Total Building Supply CFM: 706 (4.7 AC/hr) CFM Per Square ft.: 0.630 Square ft. of Room Area: 1,120 Square ft. Per Ton: 650 Building Loads Total Heating Required With Outside Air: 11,648 Btuh 11.648 MBH Total Sensible Gain: 15,518 Btuh 75 % Total Latent Gain: 5,140 Btuh 25 % Total Cooling Required With Outside Air: 20,658 Btuh 1.72 Tons (Based On Sensible + Latent) 1.72 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac - Residential & Light Commercial HVAC.Loads Elite Software 'DevelopmA�ln Miller's Central AirE. Lake Placid, FL 33852 OiNk Building Pie Chart Building Loss 11,648 Btuh Floor 27. Roof 9.521 Wall 18.54% Glas Door 2 - Building Gain 20,658 People 15.3 Btuh Appliances 15.05% 91% r 6.39% 21.11% C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Millers Central Air E.O. Koch Lake Placid, FL 33852 Page 7 Building Bar Graph 4,000 3,000 Building 2,000 Loss 11,648 Btu h 1,000 0 Floor 27.53% Wall 18.54% Door 6.39% Roof 9.52% Glass 21.11 % Infiltration 16.91 % 10,000 8,000 Building Gain 20,658 4,000 Btuh . 2,000 0 Roof 6.98% Glass 6.19% People 15.39% Lighting 41.84% Wall 3.94% Door 2.23% Appliances 15.05% Infiltration 8.38% C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac --Residential & Light Commercial HVAC Loads Miller's Central Air ON Elite Software Development, Inc. E.O. Koch Lake Placid, FL 33852 Page 8 System 1 Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 1 C Window Clear Glass Metal Frame 71 2,459 0 1,278 1,278 11A Door Metal Fiberglass Core 42 744 0 460 460 14C Wall 8" or 12" Block + R-11 935 2,159 0 813 813 16G Ceiling Under Vent. Attic - R-30 Insulation 1120 1,109 0 1,441 1,441 22A Slab on Grade No Edge Insulation 132 3,207 0 0 0 Subtotals for structure: 9,678 0 3,992 3,992 People: 6 1,380 1,800 3,180 Equipment: 2,520 590 3,110 Lighting: 2535 8,644 8,644 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 60, Summer CFM: 30 1,970 1,240 492 1,732 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Sensible Gain Total: 15,518 Temperature Swing Multiplier: X 1.00 System 1 Load Totals: 11,648 5,140 15,518 20,658 Check .Figures Supply CFM: 706 (4.7 AC/hr) CFM Per Square ft.: 0.630 Square ft. of Room Area: 1,120 Square ft. Per Ton: 650 System Loads Total Heating Required With Outside Air: 11,648 Btuh 11.648 MBH Total Sensible Gain: 15,518 Btuh 75 % Total Latent Gain: 5,140 Btuh 25 % Total Cooling Required With Outside Air: 20,658 Btuh 1.72 Tons (Based On Sensible + Latent) 1.72 Tons (Based On 75% Sensible Capacity) Notes .-....... . Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary., Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc.. Miller's Central Air E.O. Koch Lake Placid, FL 33852 Page 9 System 1 Pie Chart System 1 Loss 11,648 Btuh Floor 27.5 Roof 9.52% Wall 18.54% Roof 6. Wall 3.94% Glass 6.19% \ Door 2.23% System 1 Gain People 15.3 20,658 Btuh Appliances 15.05% 1% 6.39% nfiltration 8.38% Lighting 41.84% C:\Elite\Rhvacw\Projectskeokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.. Miller's Central Air ON E.O. Koch Lake Placid, FL 33852 '' Page 10 S stem 1 Bar Graph 4,000 3,000 System 1 2,000 Loss 11,648 Btuh 1,000 0 Floor 27.53% Wall 18.54% Door 6.39% Roof 9.52% Glass 21.11 % Infiltration 16.91 % 10,000 8,000 System 1 Gain 4 000 20,658 ' Btuh 2,000 0 Roof 6.98% Glass 6.19% People 15.39% Lighting 41.84% Wall 3.94% Door 2.23% Appliances 15.05% Infiltration 8.38% C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM &Light Commercial HVAC Loads Elite Software Development, Inc. [Rhvac7-Residential iller'ntral Air E.O. Koch ake , FL 33852 Page 11 S stem 9, Zone 1 Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 1C Window Clear Glass Metal Frame 71 2,459 0 1,278 1,278 11A Door Metal Fiberglass Core 42 744 0 460 460 14C Wall 8" or 12" Block + R-11 935 2,159 0 813 813 16G Ceiling Under Vent. Attic - R-30 Insulation 1120 1,109 0 1,441 1,441 22A Slab on Grade No Edge Insulation _ _ _ _ 132 _ _ 3,207 0 0 0 Subtotals for structure: 9,678 0 3,992 3,992 People: 6 1,380 1,800 3,180 F,quipment: 2,520 590 3,110 Lighting: 2535 8,644 8,644 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 60, Summer CFM: 30 1,970 1,240 492 1,732 Sensible Gain Total: 15,518 Temperature Swing Multiplier: _ _ X 1.00 System 1, Zone 1 Load Totals: 11,648 _ 5,140 15,518 _ 20,658 Check Figures Supply CFM: 706 (4.7 AC/hr) CFM Per Square ft.: 0.630 Square ft. of Room Area: 1,120 Square ft. Per Ton: 650 Zone Loads Total Heating Required: 11,648 Btuh 11.648 MBH Total Sensible Gain: 15,518 Btuh 75 % Total Latent Gain: 5,140 Btuh 25 % Total Cooling Required: 20,658 Btuh 1.72 Tons (Based On Sensible + Latent) 1.72 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Millers Central Air Op E.O. Koch Lake Placid, FL 33852 Page 12 System 1, Zone 1 Pie Chart Infiltration 16.91 Flnnr 77 RI%, System 1, Zone 1 Loss 11,648 Btuh Roof 9.521 Wall 18.54% Glass Door 2.2d —System - - --- - 1, Zone 1 Gain People 15.39 20,658 Btuh Appliances 15.05% r 6.39% 21.11% �o Lighting 41.84% C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Miller's Central Air E.O. Koch Lake Placid, FL 33852 Page 13 System 1, Zone 1 Bar Graph 4,000 3,000 System 1, Zone 2,000 1 Loss 11,648 Btuh 1,000 0 Floor 27.53% Wall 18.54% Door 6.39% Roof 9.52% Glass 2 1.11% Infiltration 16.91 % 10,000 ME 1, Zone 1 Gain 4,000 20,658 Btuh 2,000 0 I -- Roof 6.98% Glass 6.19% People 15.39% Lighting 41.84% Wall 3.94% Door 2.23% Appliances 15.05% Infiltration 8.38% C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Miller's Central Air ON, E.O. Koch Lake Placid, FL 33852 0 Pa a 14 Detailed Room Loads - Room 1 - Kitchen, Dining, Living Room General Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 1.0 ft. System Number: 1 Room Width: 590.0 ft. Zone Number: 1 Area: 590.0 sq.ft. Supply Air: 442 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.6 AC/hr Volume: 4,720.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 5 Actual Winter Vent.: 0 CFM Runout Air: 88 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 451 ft./min. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 34 CFM Actual Loss: 0.131 in.wg./100 ft. Actual Summer Infil.: 17 CFM Item Area -U- Htg Sen Clg Lat Sen Description Quantity Value HTM Loss HTM Gain Gain N -Wall-14C 23 X 8 140 0.077 2.3 323 0.9 0 122 W -Wall-14C 28 X 8 224 0.077 2.3 517 0.9 0 195 S -Wall-14C 13 X 8 83 0.077 2.3 192 0.9 0 72 N -Door-11A 3 X 7 21 0.590 17.7 372 11.0 0 230 S -Door-11A 3 X 7 21 0.590 17.7 372 11.0 0 230 N -GIs-1C 1-P SI-38 100%S 10 1.155 34.7 346 18.0 0 180 N -GIs-1C 1-P SI-38 100%S 13 1.155 34.7 450 18.0 0 234 UP-Ceil-16G Dark 1 X 590 590 0.033 1.0 584 1.3 0 759 Floor-22A 64 ft.. Per. 64 ------------- 0.810 24.3 1,555 ----- - --- 0.0 0 -- 0 Subtotals for Structure: 4,711 0 -- 2,022 Infil.: Win.: 34.4, Sum.: 17.2 65 17.431 1,133 4.354 713 283 People: 230 lat/per, 300 sen/per: 6 1,380 1,800 Equipment: 2,520 590 Lighting__ _ 1,475 _ _ 5,030 Sensible Gain Total: 9,725 Temperature Swing Multiplier: _ X1.00 Room Totals: 5,844 4,613 9,725 C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac = Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Miller's Central Air E.O. Koch Lake Placid, FL 33852 Page 15 Detailed Room Loads - Room 2 - Bedroom 3 General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 1.0 ft. System Number: 1 Room Width: 143.0 ft. Zone Number: 1 Area: 143.0 sq.ft. Supply Air: 72 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.8 AC/hr Volume: 1,144.0 cu.ft. Required Vent.: 0 CFM "Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 72 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual. Summer Vent.: 0 CFM Runout Air Velocity: 527 ft./min. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 8 CFM Actual Loss: 0.229 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item - Area -U- Htg Sen Clg -Lat _ Sen Description Quantity Value HTM Loss HTM Gain Gain S -Wall-14C 11 X 8 72 0.077 2.3 166 0.9 0 63 S -GIs-1C 1-P SI-38 100%S 16 1.155 34.7 554 18.0 0 288 UP-Cei1-16G Dark 1 X 143 143 0.033 1.0 142 1.3 0 184 Floor-22A 11 ft.. Per. 11 0.810 24.3 267 0.0 0 0 Subtotals for Structure: 1,129 0 535 Infil.: Win.: 8.5, Sum.: 4.2 16 17.438 279 4.375 176 70 Lighting: 286 975 Sensible Gain Total: 1,580 Temperature Swing Multiplier. X1.00 Room Totals: 1,408 176 1,580 C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Miller's Central Air E.O. Koch Lake Placid, FL 33852 Page 16 Detailed Room Loads - Room 3 - Master Bedoom General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 1.0 ft. System Number: 1 Room Width: 175.0 ft. Zone Number: 1 Area: 175.0 sq.ft. Supply Air: 104 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.5 AC/hr Volume: 1,400.0 cu.ft. Required Vent.: 0 CFM (Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 104 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 531 ft./min. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 17 CFM Actual Loss: 0.180 in.wg./100 ft. Actual Summer Infil.: 8 CFM Item Area -U- Htg Sen Cig Lat Sen Description Quantity Value HTM Loss HTM Gain Gain S -Wall-14C 12.5 X 8 68 0.077 2.3 157 0.9 0 59 E -Wall-14C 14 X 8 112 0.077 2.3 259 0.9 0 97 S -GIs-1C 1-PSI-38 100%S 32 1.155 34.7 1,109 18.0 0 576 UP-Ceil-16G Dark 1 X 175 175 0.033 1.0 173 1.3 0 225 Floor-22A 27 ft..Per. 27 0.810 24.3 656 0.0 0 0 Subtotals for Structure: 2,354 0 957 Infil.: Win.: 16.9, Sum.: 8.5 32 17.438 558 4.344 351 139 Lighting: ___ _ 350 1,194 Sensible Gain Total: 2,290 Temperature Swing Multiplier: X1.00 Room Totals: 2,912 351 2,290 C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM 1. r f Q • Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Millers Central Air & E.O. Koch Lake Placid, FL 33852 r Page 17 Detailed Room Loads - Room 4 - Bedroom 3, Bathroom General _ Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 1.0 ft. System Number: 1 Room Width: 212.0 ft. Zone Number: 1 Area: 212.0 sq.ft. Supply Air: 88 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.1 AC/hr Volume: 1,696.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 88 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 642 ft./min. Percent of Supply: 0 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 0 CFM Actual Loss: 0.338 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area -U- Htg Sen Clg Lat Sen Description _ Quantity Value HTM Loss H_TM Gain Gain E -Wall-14C 12.5 X 8 100 0.077 2.3 231 0.9 0 87 N -Wall-14C 17 X 8 136 0.077 2.3 314 0.9 0 118 UP-Ceil-16G Dark 1 X 212 212 0.033 1.0 210 1.3 0 273 Floor-22A 30 ft..Per. 30 0.810 24.3 729 0.0 0 0 Subtotals for Structure: _ 1,484 0 478 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Lighting_ 424 1,446 Sensible Gain Total: 1,924 Temperature Swing Multiplier: X1.00 Room Totals: 1,484 0 1,924 C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM is "i ) Rhvac -Residential & Light Commercial HVAC Loads t Elite Software Development, Inc. Miller s Central Air . & E.O. Koch Lake Placid, FL 33852 _page 18 Room Cooling and Heating Loads Bar Graphs Kitchen, Dining, Living Room Cooling Bedroom 3 Master Bedoom Heating Bedroom 3, Bathroom 0 5,000 10,000 15,000 Btuh :\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM A rf •. Rhvac - Residential $ Light Commercial HVAC Loads Elite Software Development, Inc. Miller's Central Air E.O. Koch Lake Placid, FL 33852 Page 19 Room Cooling Loads Bar Graphs Kitchen, Dining, Living Room Sensible Bedroom 3 Master Bedoom Latent Bedroom 3, Bathroom 0 5,000 10,000 15,000 Btuh C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM -A" I 1 .F Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Miller's Central Air E.O. Koch Lake Placid, FL 33852 Page 20 System 1 Room Load Summary Htg Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM ---Zone 1--- 1 Kitchen, Dining, Livi 590 5,844 76 5-6 451 9,725 4,613 442 1.00 442 442 ng Room 2 Bedroom 3 143 1,408 18 1-5 527 1,580 176 72 1.18 85 72 3 Master Bedoom 175 2,912 38 1-6 531 2,290 351 104 1.35 141 104 4 Bedroom 3, 212 1,484 19 1-5 642 1,924 0 88 1.00 88 88 Bathroom System 1 total 1,120 11,648 151 15,518 5,140 706 756 706 System 1 Main Trunk Size: 10x12 in. Velocity: 899 ft./min Loss per 100 ft.: 0.142 in.wg 1-Cpoling System Summary Cooling Sensible/Latent Sensible latent Total Tons Split Btuh Btuh Btuh Net Required: 1.72 75% / 25% 15,518 5,140 20,658 Recommended: 1.72 75% / 25% 15,518 5,173 20,691 Actual: 1.83 74% / 26% 16,300 5,700 22,000 Equipment Data Heating System Cooling System Type: XB 13 XB 13 Model: 2TGB3F25A1000A 2TTB3024A1000A Brand: Trane Trane Efficiency: 13 13 Sound: Capacity: 22000 22000 Sensible Capacity: n/a 16,300 Btuh Latent Capacity: n/a 5,700 Btuh P C:\Elite\Rhvacw\Projects\eokoch-bembry2.rhv Friday, July 18, 2008, 1:26 PM