Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
OFFICE USF,, ONLY: Date: Fee Due: Receipt# Permit # ALL INFO BE COMPLETE & FILLED IN TO BE ACCEPTED =` St. Lucie County Building and Zoning 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 772-462-1553 'S C 4C;e CoUn APPLICATION FOR ALUMINUM STRUCTU S PERMIT tk PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: 9152 Short Chip Circle Port Saint Lucie, FL 34986 2. S/DNAME: Lakes At PGA Village SITEPLANNAME: Laberge/Picotin Residence 3. PROPERTY TAX ID #: 3334-501-0207-000-4 4. LEGAL DESCRIPTION (attach extra sheets if necessary): Lakes At PGA Village BLK D LOT 69 5. PLAT l J 6. PAGE sL 7. BLOCK D 8. LOT 69 BOOK 1 NO. ��� �� NO. NO. 9. PARCEL SIZE: QiDSQ FT. �! ' 3 3 LOT DIMENSIONS v q ^ 1 - 3l NJ � 1 � t W. SETBACKS (ACTUAL) FRONT`. BACK RIGHT SID LEFT SIDE: 100, 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab . WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X ❑ CAREORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABrrABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X POOL ENCLOSURE N SG ❑ NEW )a EXISTING 38 X 40 1520 ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X TOTAL SQUARE FOOTAGE OF CONSTRUCTION 1520 12. VALUE OF CONSTRUCTION: $ 10,199.00 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 2119107 d OWNER INFORMATION NAME: Ronald Laberge & Louise Pico tin ADDRESS:9152 Ft 3*9ft �iO1J(� d r'i-I.cQ�(Ca CITY: QJ &PC_ STATE: !" ZIP 34986 i42 email: Q PHONE (DAYTIME): � ) 234-6741 FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTIME): (" ) CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: BUSINESS NAME: Pioneer Screen Co Inc II QUALIFIER'S NAME: Michael J Newman AnT)RFSS, 1682 SW Biltmore Street ST. LUCIE COUNTY CERT #: 4763 CITY: Port Saint Lucie STATE: FL PHONE (DAYTIME): (7 7 2) 3 40-43 93 FAX NO. 3 40-46 2 6 ZIP email: Pioneerscreen@msn.com 34984 _ ARCHITECT/ENGINEER: B DQ , Inc " ADDRESS: 1950 'NE 170th Avenue CITY: 4FTsbdri''' STATE: fl ZIP 32696 PHONE (DAYTIME): (352) 529-0080 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE.. . ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) u^"s f i s 4 ^lR 7 �■/'yam y ccE SECTION TOWNSHIP RANGE E MAP NO. Additional s ZONING LAND USE �� LOT CVG % Permits Lno REPORT CODE 11 BIMS FEE "r�l $ L� MISC FEES.$ $ TOTAL FEES . _ q 3 A{Fk'.?'rlS t yi Fq'FS i" :BUILDING ..& , RE8UW v. REVIEWS ZONING ZONING PLANS MISC. VEGETATION VALUE OF CONSTRUCTION REVIEWED BY EXAMINER USING ICC TABLE DATE COMPLETE INITIALS PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: AV1 2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. " 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (1) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4 h wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self: catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified.- (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ALL OF THE ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4`h wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and. to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND .DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction.1 nnderstarid that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structur nd said structure will not exceed the footprint of the structure that was in existe a prior to removal by the storms. / OWNER/ TOR SIGNATURE CO ACT R SIGNATURE STATE OF FL !Wa�w— STATE OF FLORIDA COUNTY OF COUNTY OF 5� W CC_t� The foregoing instrument as acknowledged fore a this -Ls' ay of �, 2009 by , who is personally known to me or who ha ,produced Signature of Notary Kevin J Start (SEAL) ' _ ' W Commission OD364413 Expires October 29, 2003 IMPORTANT NOTICES: The foregoing ins uument was acknowledged efgre me this �*ay of , 200 by ►o is personally known to me or who has produced • �. as identification. Signature of Notary (SEAL) Y, Kevin J Stewart • My Commission DD354413 o, w Expires October 28, 2000 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING. FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILMILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. OFFICE U ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and Zoning 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 772-462-1553 APPLICATION FOR ALUMINUM STRUCTU S PERMIT PROTECT INFORMATION 1. LOCATION/SITE ADDRESS: 9152 Short Chip Circle Port Saint Lucie, FL 34986 2. S/DNAME: Lakes At PGA Village SITEPLANNAME: Laberge/Picotin Residence 3. PROPERTY TAX ID #: 3334-501-0207-000-4 4. LEGAL DESCRIPTION (attach extra sheets if necessary): Lakes At PGA Village BLK D LOT 69 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. �� D NO. NO. 69 P) PL • Z. 9. PARCEL SIZE: (9ZE)SQ FT. ®' LOT DIMENSIONS X IV f ,..13 1:0. SETBACKS (ACTUAL) FRONT6 BACK^ RIGHT SIDEc,,� LEFT SIDE:�,� ' i 11. TYPE OF STRUCTURE (CHECK ALL APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM ❑ NEW ❑ EXISTING X ❑ CARPORT/PATIO ROOF ❑ NEW ❑ EXISTING X ❑ HABITABLE GLASS ROOM ❑ NEW ❑ EXISTING X ❑ SUNROOM ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X EX POOL ENCLOSURE N SG ❑ NEW ?a EXISTING 38 X 40 1520 ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet ❑ ROOF SYSTEM OVER EXISTING ACCESSORY STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X TOTAL SQUARE FOOTAGE OF CONSTRUCTION 1520 12. VALUE OF CONSTRUCTION: $ 10,199.00 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCAV Form No.: 001-02 Rev. 2119107 d OWNER INFORMATION NAME: Ronald Laberge & Louise Picotin ADDRESS: /' � CITY: D,.,.,- S ,,;,,,- T,,,.; p STATE: ZIP 34986 PHONE (DAYTIlVIE): �J i4234-6741 email: q FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SEMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTI]ME): CONTRACTOR INFORMATION � 47 63 STATE OF FLORIDA RUG./CERT #: ST. LUCIE COUNTY CERT #: BUSINESS NAME: Pioneer Screen Co Inc II QUALIFIER'S NAME: Michael J Newman ADDRESS: 1682 SW Biltmore Street Port Saint Lucie STATE: FL CITY: PHONE (DAYTRVIE): 7( 72) 340-4393 FAX NO. 340-4626 VA 34984 email: Pioneerscreen@msn.com ARCHITECT/ENGINEER: BDQ, Inc ADDRESS: 1950 NE 170th Avenue CITY:ill i sf STATE: f 1 21p 326.96 PHONE (DAYTIME): (352 1529-0080 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. ❑ 2 scaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. ❑ 2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for -construction unrelated to storms) . OFFICE USE,ONL LJ!'y:, SECTION I TOWNSHIP ` RANGE F, MAP NO. lV ,• 3 `�f Additional Yes ZONING LAND USE LOT CVG % Permits no REPORT CODE 11 BRAS FEE77- MISC FEES $ TOTAL FEES • :BUILDING ":& ZONING REW T h..,' :. MISC. VEGETATION OF CONS ION V�USING REVIEWS ZONING ZONING PLANS ICC TABLE REVIEWED BY EXAMINER DATE 1 , I �6 COMPLETE `cJ / rl PLAN RT 71EW SPECIFICATION C[;_��CKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: AM2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the.AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`s wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self - catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAYBE CONSTRUCTED; SO LONG AS THEY MEET -ALL OF THE` ABOVE REQUIREMENTS AND MUST BE IN STRICT COMPLIANCE WITH AAMA/NPEA/NSA2100.02 AND MEET THE FOLLOWING ADDITIONAL ITEMS: (1) The designer or engineer will state on all Plans, which Category of Design [3.1.2] will be used, inclusive of the definition. (2) If designing a Category 4 or Category 5 structure, as defined in the current Edition of 3.1.2.4 and 3.1.2.5, proper energy calculations and long form equipment sizing calculations shall be required, pursuant to Chapter 13 of the current State of Florida Building Code. (V) MOBILE HOMES (FAC 15C-2.0081- FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4a' wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIFICATION: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR WROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF'COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established -by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contr for / 07iler Builder, have verified that the existing foundation meets the quirements of the Engineer of Record an m ad a e condition to withstand the uplift and weight of the aluminumture said structure will not exceed th otprin o tfhe structure that was in existence prior to removal by the sto OWNEtCO CTOR SIGNATURE CO CTOR NATURE STATE OF FLORIDA' COUNTY 017 � . �1 s n o STATE OF FLORIDA COUNTY OFS� A r. The foregoing instrument fas acknowledged before me this` day of 11.U4, 20LK by who is personally known to me or who has produced 4 i)L -Q ` KtlA4(Y aCVs identification. N Signature of Notary IN Kevin J Stdmd (SEAL) N MyCommission DD354413 orrw� Expires October 29, 2WO IMPORTANT NOTICES: The foregoing instpment was acknowledged t before me this, day o kL , 20—C&by who is personally known to me or who has produced as identification. ,: Signature of Notary (SEAL) ��'� Kevin J Stea®R My Comte DD354413 or Expires October 29.2008 • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILIDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON TIE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILIBILITy, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. L46 16 ST LUCIE COUNTY BOARD OF COUNTY PUBLIC WORKS COMMISSIONERS DEPARTMENT BUILDING & ZONING DIVISION FAX COVER SHEET FAX #: (772) 462-2522 PHONE #: (772) 462-1553 DATE: '1 I"1 I OR NO. OF PAGES INCL. COVER: TO: ATTN• RE: e SENDER: llllok PHONE #;�.� COMM Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucleco.gov/ce PROPERTY INFORMATION Address: 9152 SHORT CHIP Cir City / State / Zip: PORT ST LUCIE Parcel # : 3334-501-0207-000/4 Zoning: PUD APPLICATION INFORMATION Permit Number: 0807-0071 Activity Type: . Other Permit Type: Pool Enclosure CONTRACTOR INFORMATION Contractor Name: NEWMAN MICHAEL J Review Comments FL 34986 Jurisdiction: St. Lucie County Lot# : 69 Block: D Business Name: PIONEER SCREEN COMPANY INC II Business Addr: 1682 SW BILTMORE ST City I State I Zil PORT ST LUCIE, FL 3498 REVIEWS AND COMMENTS Page 1 Owner(s): RONALDLABERGE LOUISE PICOTIN Application Type: Building Permit w/o subs Other Activity: ALUMINUM STRUCTURE Stories: 1 Automatic Sprinkler System? ❑ Fax Number 772-340-4626 Review Type Status Reviewed By Date Started Date Complete Date Released Zoning Review Pending 07/07/2008 07/07/2008 1 Comment THE SIGNATURE PAGE IS INCORRECT. THE OWNERS SIDE IS SIGNED BY AN AGENT. THIS AGENT IS NOT A REGISTERED AGENT ACCORDING TO FLORIDA DEPARTMENT OF STATE DIVISIONS. CONTRACTOR IS ALLOWED TO SIGN BOTH SIDES. YOU NEED TO BRING IN A NEW SIGNATURE PAGE WITH ORIGINAL SIGNATURES SIGNDE AND NOTARIZED, YOU CAN BRING THIS IN WHEN THE PERMIT IS READY FOR PICKUP * TRANSMISSION VERIFICATION REPORT TIME 07/07/2008 13:14 NAME FAX TEL SER.# BROH5J320634 DATEJIME 07/07 13:14 FAX NO./NAME 93404626 DURATION 00:00:27 PAGE(S) 02 RESULT OK MODE STANDARD ECM DATES TO Si LUCIE COUNTY BOARD OF COUNTY COMMISSIONERS PUBLIC WORKS DEPARTMENT BUILDING & ZONING DIVISION FAX COVER SHEET FAX #: (772) 462-2522 PHONE #: (772) 462-1553 NO. OF PAGES INCL. COVER:_ ATM RE: ` SANDER: PHONE #;cwj t COMME 0 Property Appraiser - St.Lucie C,. --ity, FL Page 1 of 1 1 / PROPERTY RECORD CARD Michael Brachfeld Record: 1 of 1 «Prev Next» Spec.Assmnt Taxes Exemptions Permits Home Print Property Identification �UCIE qGy Site Address: 9152 Short Chip Cir ParcellD: 3334-501-0207-000-4 `�� e Sec/Town/Range: 34:36S:39E Account #: 155039 Map ID: 33/34N Land Use: SF Res Zoning: PUD City/Cnty: ST. LUCIE COUNTY Ownership and Mailing Legal Description Owner: Michael Brachfeld Jeffrey Berman LAKES AT PGA VILLAGE (PB 43-32) BLK D LOT 69 (OR 2480-2241) Address: - 6711 S Grande Dr Boca Raton FL 33433 Sales Information Assessment Final Total Land and Building Date Price Code Deed Book/Page 2007 FV: 290400 Land Value: 105000 Acres: 0.33 2/2/2006 323400 00 SP 2480 / 2241 Assessed: 290400 Building Value: 185400 4/21/1998 21320600 04 WD 1140 / 1945 Ag.Credit: 0 Finished Area: 2116 SgFt Exempt: 0 Taxable: 290400 Taxes: 5484.73 BUILDING INFORMATION iu n ovwy m i�7e 4 7,7„7 1. �M e m �OYNI (M7 No--, IYna Available Exterior Features View: - RoofCover: TC - Clay Tile RoofStruct: HP - Hip ExtType: HA- - HA- YearBlt: 2006 Frame: - Grade: A- - A- EffYrBit: 2006 PrimeWall: BS - CB Stucco StoryHght: 0010 - 1 Story No.Units: 1 SecWall: - Interior Features BedRooms: 3 Electric: MX - MAXIMUM PrmintWail: DW - Drywall FullBath: 2 HeatType: FHA - FrcdHotAir AvgHUFI: STD 1/26ath: 0 HeatFuel: ELEC - Electric Prm.Flors: CT - Tile -Ceramic %A/C: 100 . %Heated: 100 %Sprinkled: 0 Special Features and Yard Items Land Information Type Y/S Qty. Units Qual. Cond. YrBit. No. Land Use Type Measure Depth DWC - Driv-Concret Y 1 703 AV AV 2006 1 0100-SF Res LFI -Site 1 THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED. http://www.pasle.org/pre.asp?prclid=333450102070004 7/2/2008 EDWIN M. FRY, Jr., C, C OF THE CIRCUIT COURT - SAINT LUCIE P TY FILE # 3218636 OR B.;— 2983 PAGE'1229, Recorded 06/11/2008(,03:00 PM Doc Tax: $1634.50 Prepared by, record & return to: Karen Rae Hyche PRESTIGE TITLE AGENCY, INC. 73e Colorado Ave. Stuart FL 34994 Property Appraisers Parcel ID#: 3334-501-0207-000/4 THIS WARRANTY DEED, Made the -73— day of May, 2008 by MICHAEL BRACHFELD and JEFFREY BERMAN hereinafter called the Grantor, to RONALD LABERGE and LOUISE PICOTIN, husband and wife 229 Martinique, Dollard des Ormeaux whose post office address is Quebec, Canada H9G 2Y4 hereinafter called the Grantee. - -- 1Wh.rtr .u.ed .herein the. terms -Grantor' and 'Grantee' include all the Parties to thin in.trument and the heirs. 109.1 reproaeatsti— and assign of individuals, and the au—sors and aosipna of coryorationo, vharevor the content sa admit. or recuires.I Witnesseth, That the Grantor, for and in consideration of the sum of $10.00 and other valuable considerations, receipt whereof is hereby acknowledged, hereby grants, bargains, sells, aliens; remises, releases, conveys and confirms unto the Grantee all that certain land, situate in St.LUCIe County, State of Florida, viz: Lot 69, Block D, LAKES AT PGA VILLAGE, according to the plat thereof, recorded in Plat- Book 43, Page 32, Public Records of St. Lucie County, Florida. - SUBJECT TO restrictions, reservations, easements & conditions. of record; all governmental zoning. Grantors herein state said property is not their homestead nor is it contiguous thereto. Grantors maintains their homestead at Michael Brachfeld: S ►i FL J.Ty33 Jeffrey Berman: 5628 NW 100th Way, Coral Springs ,T, 33 6 Together, with all the tenements, hereditaments and appurtenances thert6 belonging or in anywise appertaining. U . To Have and to Hold, the same in fee simple forever. And the Grantor hereby covenants with said grantee at t grantor is lawfully seized of said land in fee simple; that the grantor has good right and wful au ority to sell and convey said land, and hereby warrants the title to said land and will fend th same against the lawful claims of all persons whomsoever; and that said land is free o ehc ances, except taxes accruing subsequent to December 31, 2007. _ In Witness Whereof, the said Grantor has signed and first above written. Signed, sealed and delivered in the esence of: witness Sign uree(as to �first. -t,raanntoi/i�f�!►. Print name- J4M/11 SJ I J LiF:iIY�. Y� first e presents the day and year 1� ��� rartor signet e Michael Brachfeld 6,711 .S G Post Office Address - ' 3m0. tof� Pe, 734133 STATE OF FLO��A) / I hereby Certify that on this day, COUNTYOF before me, an officer duly authorized to administer oaths and take acknowledgments, personally appeared MICHAEL BRACHFELD known to me to be the person(s) described in and who executed the foregoing instrument, who acknowledged before me that he/she/they executed the same, and an oath was not taken. (Check one): ❑ Said persons) is/are personally known to me. M Said person(s) provided the. following type of identification: — t I �%I cif/ 70 fFG3 D . HENRY RENAUD SEAL _ WCOMMISSION#DD561342 :( EXPIRES June 2Q MY COMMISSION E �y� e0ft? Witness my hand and official seal in the County and State last aforesaid 0As 10.. dq of May, 2008A Notaf, signet a Print name C� OR BOOK 2983 PAGE r ~0 �_ Warranty Deed cant. Co- an ignature, if any Jeffrey Pan 92? ,uw i00'hc-7r Co ol5�..��s, R33o� Post Office Address STATE OF FL�IDA) I hereby Certify that on this day, COUNTY OF )L Ct A ) before me, an officer duly authorized to administer oaths and take acknowledgments, personally appeared JEFFREY BERMAN known to me to be the person(s) described in and who executed the foregoing instrument, who acknowledged before me that he/she/they executed the same, and an oath was not taken. (check one): ❑ Said person(s) is/are-personally known- to -me. 0 Said person(s) provided the following type of identification: _F/d�idn �Y/VPY LicPncL SEAL Witness my hand and official seal in the County and State last aforesaid MY COMMISSION EXPIRES: //�a �� 9 this��J -3 day o(ff may, _ 2008. Notary Signature DWELEorg:J 8 Print name: 1 Q ✓IC L -Tk aYKar N"PAft- •NyOdedrbnEQamN & lgidd IiYo www.sunbiz.org - Department ,� `state Page 1 of 2 l Home Contact Us E-Filing Services Previous on List Next on List Return To List Events No Name History Detail by Entity Name Florida Profit Coraoration PIONEER SCREEN COMPANY, INC. II Filing Information Document Number L28972 FEI Number 650165883 Date Filed 11/09/1989 State FL Status ACTIVE Last Event CANCEL ADM DISS/REV Event Date Filed 10/19/2004 ` Event Effective Date NONE Principal Address 1682 SW BILTMORE STREET PORT ST. LUCIE FL 34953 Changed 06/15/1995 Mailing Address 1682 SW BILTMORE STREET PORT ST. LUCIE FL 34953 Changed 06/15/1995 Registered Agent Name & Address NEWMAN, MICHAEL J 726 SE ADAMS COURT PORT ST LUCIE FL 34984 US Name Changed: 06/15/1995 Address Changed: 11/19/2002 Officer/Director Detail Name & Address Title PO NEWMAN, MICHAEL J PRES 726 SE ADAMS CT PORT SAINT LUCIE FL 34984 Title VP NEWMAN, JODI B VP 726 SE ADAMS CT PORT SAINT LUCIE FL 34984 Document Searches Forms Help Entity Name Search http : //www. sunbiz. org/scripts/cordet.exe?action=DETFIL&inq_doc_number=L28972&inq_... 7/7/2008 Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucieco.gov/ce Date: 02 July 2008 Job Address: 9152 SHORT CHIP Cir Received By: gersteml Paid With: CK Paid By: A & G CONCRETE POOL INC Building Receipt Receipt M 0000063993 'ermit Number: SLC- 0807-0070 Amount: $100.00 �redit Card Number: Check Number: 55878 Sign: EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3225550 OR BOOK ' 19 PAGE 738, Recorded 06/26/2" ''1 at 02:00 PM AFTER RECORDiN .- FTrrRN TO, i PER TNLRRBER This SpaceL- resersodforremnlingfufu NOTICE OF COMMENCEMENT The undersigned herebygiven notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following Information is provided in the Notice of commencement r 1. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER -so) -,=rf) -Uoo -� 2. GENERAL DESCRIPTION OFIWROVE�IOIENT:InstaI Screen / Pool Enclosure 3. OWNER INFORMATION: a Name �*'�\A -;. LIN A; �• L(�,�� � , C �� b. Address �I ��� Qiry .r % t�i .; n C.m 1, e �)r i ) I l o �. interest in property d. Name and address of fee simple titleholder (if other than owner) -4.CONTRACTOR'SNANM ADDRESS AND PHONE NUMBER. • Pioneer Screen Co Inc II 1682 SW Biltmore Street Port Saint Lucie, FL 34984 (772) 340-4393 5, SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAAM ADDRESS AND PHONE NUMBER 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1)(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBEM g. in addition to himself or herselt; Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is I year fmm the date of recording unless a different date is specified) 20 Print Name and Provide Signatory's Title/Office Owner's Auth4rrized Officer/Director/Partner/Manager State of Florida County of Cr The f regotng (Irstnunent aclaowigdg�ed before me this o�C/ day of �ua�IN, 20�. By Off tS f, �' CO I Al as ( _yrleir� (Name ofperson) (Type of authority... e.g. Owner, officer, trustee, attorney in fact) Zbeoo 'sm mcndomm, Personally Known or produced the following type of M: �L Kevin J SMiwt to Public y A4y Cammis�fori OD3t�413 tary ) (Signs of Notary Public) (seal) 1M � Wires oebber 29, 20M Under penalties of perjury, I declare that I have read the foregoing and that the facts in it are true to the best of my Imowledge and belief (section 92.525, Florida Statutes). STATE OF FLORIDA Signature(s) of Owner(s) or Owner(s)' Authorized Officer/Director/Partner/Manager who. signed above: ST. LUCIE COMM Y � nrT. THIS T O CERT1F8'yVj41 By y% / 6;f}i ) �^ �a� _�r, �U Q1' T R U E A I'J D C O c t; "f -O F T(Sign '� �.` (Printed Name) 0RIGI1,9AL. �F.D M. F, ` JR., ^LE K Date: Code Compliance Division -- BUILDING PERMIT 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce Page 1 Issued: 07/23/2008 Job Location: 9152 SHORT CHIP Cir Permit Type: Pool Enclosure Job Description: Conf #: 726 Permit #: SLC- 0807-0071 City: PORT ST LUCIE INSTALLATION OF POOL ENCLOSURE - POOL - 0807-0070 S/D LAKES AT PGA VILLAGE Lot: 69 Block: D Parcel: 3334-501-0207-000/4 Setbacks Left: 22.36 Right: 36.00 Front: Rear: 13.00 Zoning: PUD Number of Units: 1.00 Floors: 1 . Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: 275E Flood Zone: X Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. . . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. -- - -__ vVi- WLI)-I DATE FILED: L() REVISION FEE:_ PERM NUMBER: `7 — 60 f RECEIPT NO.: ( (at. l A • - ST. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVELOPME1147 BUILDNG & ZONING 2300 VIRGINIA AV , FORT PIERCE, FL 34 2 g� .462-155.3 APPLICATION ION FQR BUILDIM PROJECT INF0R3X AT10.N I • LOCATI Oti!SIT.E ADDRESS: 9 I5 2 S H40R T C-H 1P 2. DETAILED DESCRIPTION'S OF PROJECT ��l of M1 vp, � RED' SIONS: ALUM lad rink F�6 L4 IZ.60F W6,5 �, c AfoT A L60 S c6?j T LQ oo5--T5 Eli 61 ie-rjzlgg' 3. CO\TR.ACT0R INF0R.VIAT(ON : ST. OF FL RECJCERT# N/A ST. LCCIE COUNTY CERT.;� 4763 $i:SitiE55 tiAtiIE: Pioneer Screen Co., Inc., II Qualifiers `ame: Michael J Newman ADDRESS: 1682 SW Biltmore Street CITY: PHO-N (DAYT#}IE): Port Saint Lucie 772 340-4393 • STATE:. FL - ZIP: 34984 _ FAQ# 772 340-4626 4. .ARC.RIVELGItiEER: NAME: BDQ, Inc. ADDRESS: 1950 NE 170th Avenue CITY: PHO-NE (DAYTIME): Williston 352 529-0080 STATE: FL �IP:`32969 FAQ 352 529-0081 Building Code Compliance Division 2300 Virginia Avenue Receipt Ft. Pierce, FL 34982 Phone: (772) 462-1SO Fax: (772) 462-1578 http://www.stlucieco.org/public—works/permitting.htm Date: 27 October 2008 Job Address: 9152 SHORT CHIP Cir Received By: gersteml Paid With: CK Paid By: PIONEEER SCREEN CO INC H Sign: Receipt #: 0000066114 'ermit Number: SLC- 0807-0071 Amount: $50.00 '-redit Card Number: Check Number: 49380 _ -DESIGN NOTES: 1. ALL DIAGONAL BRACING SHOWN IN BOTH THE ROOF AND WALLS SHALL BE 2 x 2 x .093 TUBE MATERIAL. 2. 15 x 14 MESH SCREEN IS THE MAXIMUM ALLOWABLE DENSITY FOR THIS ENCLOSURE'S DESIGN. 3. DOOR(S) MAY BE PLACED INTO ANY SCREEN WALL PANEL EXCEPT 1=0fR THOSE THAT CONTAIN DIAGONAL BRACING. i V O' HEIGHT i PIONEER SCREEN CO., II SCREEN ROOF / ALUM. ROOF ENCLOSURE FOR: LABERGE RESIDENCE 9152 SNORT CHIP CIR. PORT ST. LUCIE, FLORIDA THIS SYMBOL REPRESENTS DIAGONAL ® WIND 5RACING (IN 50TH THE ROOF AND WALLS), 2 x 2 x .093 TUBE MATI_. I x 3 THIS PANEL IS 5EINCx w _ INSTALLED UNDER tNE _ x EXIST. HOUSE R x X x N � N Ix3 I r- 1 N - 9 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPL►CABLE CODES, OVERALL DESIGN COMPLIES WITH THE 200(o AMENDMENTS TO THE F.B.C. 2004 BUILDING CODE, FOR 140 MPH WIND LOAD (3-SECOND GUST), FOR EXP. CAT, "C" (NON-H.V.H.Z.). x m x N e x 0 x m 0 THIS SYMBOL REPRESENTS BEAM SPLICE LOCATIONS EXIST. HOST FASCIA OOF F- /X2 xX °1 I' @_ ' MIN. EXIST. HOST FASCIA I x 2 x3x.010 2x3x.010 /x3x'010 2x3x.010 X%2x 9^ 0^ 61^ 9^ Bs N N N N N 2x3x.0'10 x3x.07 V[12x3,x.010 XXX2x3xOI 113. 13' 1 1 1 3' --- —1 1131 1 1' 3' 1 5' 6' I 5' 6' 40' 0' OVERALL ENCLOSURE WIDTH 9 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPL►CABLE CODES, OVERALL DESIGN COMPLIES WITH THE 200(o AMENDMENTS TO THE F.B.C. 2004 BUILDING CODE, FOR 140 MPH WIND LOAD (3-SECOND GUST), FOR EXP. CAT, "C" (NON-H.V.H.Z.). x m x N e x 0 x m 0 THIS SYMBOL REPRESENTS BEAM SPLICE LOCATIONS EXIST. HOST FASCIA OOF F- /X2 xX °1 I' @_ ' MIN. EXIST. HOST FASCIA I x 2 x3x.010 2x3x.010 /x3x'010 2x3x.010 X%2x 9^ 0^ 61^ 9^ Bs N N N N N 2x3x.0'10 x3x.07 V[12x3,x.010 XXX2x3xOI 113. 13' 1 1 1 3' --- —1 1131 1 1' 3' 1 5' 6' I 5' 6' 40' 0' OVERALL ENCLOSURE WIDTH 113. 13' 1 1 1 3' --- —1 1131 1 1' 3' 1 5' 6' I 5' 6' 40' 0' OVERALL ENCLOSURE WIDTH XXIx2 x xx x N (TYP) N N N 3x3x.010 Ix2 4 x m x m 11 d 9 r i ° rn M ° N r N>� .J 0 w o Z p°COZc°rv0 W O N�coO ° F- L� d owLL Z Q co 0 U2oi- no o' OC oL9U ° no °'wcoZ ° mooa) Lo LL 1,3, I 5.6. I 5' 6' r t- r r -•-i THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS Hb IMAI FA5RIGATION / INFALLATION REQUIRED GUIDELINE5: NOTE: ANY J055 THAT REQUIRE 51TE-SPECIFIC DE51GN / ENGINEERING MUST BE SUBMITTED TO THE ENGINEER OF RECORD FOR SUCH DESIGN CONSIDERATION PRIOR TO THE JOB BEING PERMITTED, FABRICATED OR INSTALLED. LEAD-TIMES FOR SUCH WORK WILL DEPEND ON OUR CURRENT WORK LOAD AT ANY GIVEN TIME. THE ITEMS BELOW ARE NOT PERMITTED ON ANY ENCLOSURE WITHOUT SITE -SPECIFIC DESIGN 4 AUTHORIZATION FROM THE ENGINEER OF RECORD, I. NO SCREEN ROOF BEAMS SHALL BE LOCATED WITHIN 12-INCHES OF. ANY OUTSIDE COINER OF ANY WALL, FASCIA OR STRUCTURAL GUTTER 2. NO CABLE BRACING SHALL BE USED ON ANY ENCLOSURE AT ANY TIME FOR THE RESISTANCE OF ANY IMPOSED DESIGN LOADING. 3. THERE SHALL BE NO SUBSTITUTION OF EITHER CONCRETE ANCHOR TYPE OR MANUFACTURER OTHER THAN THOSE SPECIFIED ON THESE ENGINEERED DESIGN DRAWINGS. 4. THERE SHALL BE NO SCREENING UTILIZED THAT IS FINER THAN 18 x 14 MESH SCREEN WITHOUT SITE -SPECIFIC DESIGN (THAT SHALL BE DONE PRIOR TO THE JOB BEING FABRICATED OR INSTALLED) WITH JOB DRAWINGS BEARING THE ENGINEER OF RECORDS ORIGINAL SIGNATURE (IN BLUE IWJ UNDER HIS EMBOSSED. SEAL. 5. ALL SCREEN ROOF ENCLOSURES MUST BE POSITIONED ON THE EDGES OF THE CONCRETE DECK SO THAT THE OUTER SURFACE OF THE SCREEN FRAME IS NO LESS THAT 2 3/4 - INCHES IN FROM THE EDGE, TO CREATE PROPER EDGE DISTANCE FOR THE SPECIFIED CONCRETE ANCHORS AT THE BASE OF EACH COLUMN. 6. ALL ROOF PURLINS IN THE.ROOF AND CHAIR RAILS IN THE WALLS SHALL NOT EXCEED 8-FEET CENTER - TO - CENTER SPACING (SEE APPROPRIATE DETAILS ON OTHER SHEET$ OF THIS DRAWING FOR SPECIFIED MATERIAL SIZES REQUIRED FOR ANY GIVEN APPLICATION. 1. NO SCREEN ROOF ENCLOSURE SHALL BE INSTALLED UTILIZING SEVEN-INCH STRUCTURAL GUTTER AS IT IS NOT PERMITTED, OR STRUCTURALLY ADEQUATE UNDER THIS ENGINEERING. THE ITEMS BELOW MUST BE 5U5MITTED TO THE ENGINEER OF RECORD PRIOR TO MEASURING 47LAYOUT, FABRIGATION�. OR INSTALLATION FOR THE REQUIRED SITE -SPECIFIC DESIGN. I. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES ROOF BEAMS THAT EXCEED 40-FEET IN SPAN, AT ANY POINT ON THE ENCLOSURE. 2. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES WALL COLUMNS (UPRIGHTS) THAT EXCEED 12-FEET IN HEIGHT AT ANY POINT ON THE ENCLOSURE. 3. ANY ENCLOSURE THAT UTILIZES ANY CARRIER BEAM (A BEAM THAT ACTS AS SUPPORT FOR ANY OTHER SCREEN ROOF BEAM) AT ANY POINT ON THE ENCLOLSURE. NO CARRIER BEAM SHALL BE PERMITTED TO BE MOUNTED TO .THE FASCIA OF ANY HOST STRUCTURE (AS PRIMARY SUPPORT). 4. INSTALLATION OF ANY SCREEN ROOF ENCLOSURE ON AN EXISTING HOUSE FASCIA WHERE THE OVERHANG EXCEEDS 2-FEET. NOTE THAT IF THE EXISTING RESIDENCE WAS CONSTRUCTED UNDER ANY BUILDING CODE PRIOR TO F.B.C. 2001, THE JOB MAY REQUIRE FOURTH -WALL TYPE CON5T., AS THERE IS NO WAY TO CERTIFY THE ABILITY OF A HOST STRUCTURE THAT WAS ONLY BUILT TO WITH- STAND 110 MPH WIND LOADS OR LESS, (AS WAS REQUIRED UNDER PREVIOUS BUILDING CODES) TO RESIST THE. IMPOSED LOADS OF AN ENCLOSURE THAT IS DESIGNED TO WITHSTAND THE LOADS IMPOSED UNDER THE 140 MPH WIND LOAD SPECIFIED IN THE CURRENT BUILDING CODE, IINT CONNECTION NOTE: II ALL FRAMING MEMBERS ON ANY ENCLOSURE THAT UTILIZE SNAP OR LAP JOINT IN THEM SHALL HAVE 12 TEKS INSTALLED THRU THE SNAP OR LAP CONNECTION AT 18 INCHES ON CNTR (TYP). THESE TEK SCREWS ARE TO BE PLACED ON BOTH EDGES OF .THE UPRIGHT (BOTH THE INNER AND THE OUTER EDGE) IN ALL CASES. THIS SPECIFICATION APPLIES TO UPRIGHTS AND BEAMS BOTH. MINIMUM FOOTER TA5LE5 MONO MAX. BM. FOOTER SPAN ' x 8' WITH (U w50 CONT. UP TO 38' Vx12'WITH (1) c5o CONT. UP TO 41' 10' x 12' WITH (1) BO CONT. UP TO 48' 12' x 12' WITH (2) OBO CONT UP TO 55' ISOLATED I MAX. BM. FOOTERO) SPAN 12' x 12' WITH (2) 450 CONT. UP TO 30' 12' x IV WITH (2) W50 CONT. 31' TO 39' 14'x16'WITH 0't044' (2) T50 CONT. v x I( . WITH 44' TO 52' (2) 050 CONT, IF A J08 EXCEEDS THESE PARAMETERS, THE FCUNPATioN MUST BE SITE -SPECIFICALLY DESIGNED BY THE ENGINEER MONOLITHIC FTG. LOAD CAPACITIES ARE BASED ON A MIN. OF 3 FEET OF CONT. CONCRETE, 2AOO PSI MINIMUM, W/ WIRE OR FIBERMESH REINFORCEMENT (+)ISOLATED FOOTERS MAY BE USED ON EDGE OF EXIST. CONC. SLAB OR UNDERNEATH THE PERIMETER OF BRICK PAVER DECK (ALL SIDES) THE ENGINEER OF RECORD WILL NOT BE ABLE TO CERTIFY THE STRUCTURAL INTEGRITY OF ANY EXISTING CONCRETE DECK / FOOTINGS THAT WERE INSTALLED WITHOUT PERMITS, AS THERE, WOULD BE NO RECORDS TO VERIFY CONCRETE THICKNESS', FOOTER SIZES AND THE SIZE AND QUANTITY OF STEEL RE -BARS THAT WOULD BE REQUIRED UNDER THE CURRENT BUILDING CODE STANDARDS. SCREW SPACING AND EDGE DISTANCE SPEC.'S THIS TABLE IS BASED ON THE PROPERTIES OF C-1022 LOW CARBON STEEL SMS AND SELF -DRILLING (TEK) SCREWS, WHICH ARE AN INDUSTRY STANDARD SCREW. SCREW SIZE NOMINAL SCREW DIAMETER (IN.) MIN. EDGE DISTANCE MIN, CENTER -TO - CENTER DISTANCE #5 0.156 5/16' 1/16' *10 0.188 3/8, 1/2' 012 0219 1/2' 5/8' 14 0250 1 5/8, 3/4' INTERNAL CONNECTION SPECIFICATION (UTILIZING SCREW BOSSES) ALL INTERNAL CONNECTIONS UTILIZING THE EXTRUDED SCREW BOSSES SHALL HAVE *10 5M5 SCREWS, WITH A MINIMUM EMBEDMENT INTO THE SCREW 6055 OF 1 3/4' (UNLESS OTHERWISE SPECIFIED ON ANY CONNECTION DETAIL). ALL SCREW BOSSES IN A GIVEN EXTRUSION MUST BE FILLED (EXAMPLE: THE 3 x 3 x .010 CHAIR RAIL (MINIMUM SIZE) THAT HAS SIX SCREW 505SES, MUST HAVE SIX OF THESE "10 SiMS SCREWS INSTALLED AT EACH END OF THAT COMPONENT, AT EACH CONNECTION). SCREEN PANEL INSTALLATION SPECIFICATION PLEASE NOTE THAT ALL SCREEN PANEL OPENINGS (BOTH ROOF AND WALLS) SHALL BE INSTALLED ON ALL FOUR SIDES WITH SPLINE (INDEP- ENDANT OF ALL SURROUNDING PANELS). THE ONLY FRAMING COMPONENTS THAT ARE NOT REQUIRED TO NAVE SPLINE INSTALLED IN THEM ARE ALL OF THE DIAGONAL WALL AND ROOF BRACING. MAY BE NECESSARY IN ORDER CONCRETE ANCHOR 5PECIFICATIOWP6YWITH ALL APPLICABLE ALL CONCRETE ANCHORS SPECIFIED ON THIS DETAIL SHEET ARE MANUFACTURED BY 'RED HEAD' ANCHORING SYSTEMS, AS ALL LOAD CAPABILITIES ARE BASED ON TEST DATA FURNISHED BY RED HEAD IN THEIR PRODUCT AND RESOURCE BOOK NO SUBSTITUTIONS OF ANY OTHER MANUFACTURER'S CONCRETE ANCHORS 15 PERMITTED WITHOUT SUBMITTAL ,OF THE COMPANY'S TEST DATA (TO VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN, SIGNED AND SEALED LETTER OF AUTHORIZATION FROM THE ENGINEER OF RECORD. ANY UNAUTHORIZED ANCHOR SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH THIS DESIGN. THE ANCHORS TO BE USED FOR APPLICATIONS SPECIFIED IN THIS ENGINEERING DESIGN PLAN ARE AS FOLLOWS: 1/4' DIA FASTENERS: RED HEAD ITW TAPCON (SEE INDIVIDUAL DETAILS FOR MINIMUM EMBEDMENT DEPTH INTO CONCRETE) 3/8' DIA. FASTENERS: 3/8' TRU BOLT WEDGE ANCHOR (SEE INDIVIDUAL DETAILS FOR QUANTITY OF FASTENERS NEEDED) (MINIMUM EMBEDMENT SHALL BE 3' INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) 3/6' LARGE DIAMETER TAPCON (LDT) (SEE INDIVIDUAL DETAILS FOR QUANTITY OF FASTENERS NEEDED) (MINIMUM EMBEDMENT SHALL BE 21i2' INTO CONCRETE UNLESS OTHERWISE SPECIFIED IN ANY DETAIL) FOR BRICK PAVER INSTALLATION: FOR INSTALLATION ON A BRICK PAVER DECK, THE ONLY FASTENERS THAT WILL MEET THE DESIGN CRITERIA INDICATED WITHIN THESE DESIGN SPEC.'S ARE THE RED HEAD TRU BOLT WEDGE ANCHOR (3/8' x I'), WHICH BASED ON 1/5' ANGLE, 1 x 2 O.B., 21IV THICK BRICK PAVER AND A MAXIMUM MORTAR 'BED THICKNESS OF 3/4'. THIS SCENARIO WILL STILL MEET THE MINIMUM FASTENER EMBEDMENT. IF ANY OF THESE CONTRIBUTING FACTORS EXCEED THE DIMENSIONAL BREAKDOWN INDICATED, THE JOB MUST BE PRESENTED TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC ANCHORING DESIGN. EXIST. HOUSE FA5CIA NOTES: IT SHALL BE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO INSPECT AND INSURE THE CONDITION OF THE EXISTING FASCIA, TO DETERMINE IF IT IS IN GOOD ENOUGH CONDITION TO SUPPORT THE PROPOSED SCREEN ENCLOSURE (PRIOR TO ITS INSTALLATION) ,�DE. WITH ALLOY (owvv- I t;p ONLY.1.1' SIGN D15CLAIM THERE IS NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IN THIS ENGINEERING DESIGN DOCUMENT REGARDING THE ABILITY OF ANY HOST STRUCTURE To RESIST THE BUILDING CODE SPECIFIED DESIGN LOADS IMPOSED -BY ANY PROPOSED SCREEN ENCLOSURE. SUCH CERTIFICATION WILL BE DEPENDENT ON AVAILABILITY OF ORIGINAL DESIGN AND CONSTRUCTION DOCUMENTS, AS WELL AS ORIGINAL PERMIT AND INSPECTION RECORDS FOR THE HOST STRUCTURE. CERTIFICATION OF THE HOST STRUCTURE, IF IT IS REQUIRED, WILL ULTIMATELY BE P055151-E ONLY IF THESE RECORDS CONTAIN ALL THE INFORMATION NEEDED BY THE ENGINEER TO PERFORM ALL OF THE NECESSARY ANALYSIS TO DETERMINE IF SUCH CERTIFICATION 15 EVEN POSSIBLE. co im i" co co O co.O z a w co Lo w a Lo O CD o Co �w O ¢ p o IL Z U ¢� c�A W Q C0 5 �- � �-I _ � O�22w Q SQ 0 z uw Z oa�W W �w:z-- Cn ozm 0 LLZI - Ow_ O U- zi �- N O O = ILL] Z � � ILL- ✓O O W CU r uj i- 0- U) W Uj O ~ 0 1 F p w Owl cjZANu! a? " w¢,�n:NNH z 7 � M N ¢W ..o ¢ (j LL i z ci ti L, o o c� � u LOU cd c N u- cj w a C- THESE PLANS AND ALL PROPOSED WORK GENERAL. NOTES AND DE61GN FARAMETERS: 1. THE OVERALL DESIGN COMPLIES WITH THE 2006 AMENDMENT TO THE FLORIDA BUILDING CODE 2004 (CHAPTER I6.AND 20), AND IS BASED ON THE FOLLOWING PARAMETERS: A. WIND SPEED: 140 M.P.H., 3-SECOND GUST B. EXPOSURE CATEGORY 'C' (NON-HVHZ ONLY) C. DESIGN PRESSURES AS FOLLOWS: a) SIMULTANEOUS WIND LOADING o 8 P.S.F. FOR SCREEN ROOF AND 23 P.SF. FOR SCREEN WALLS b) 300 LB LOAD APPLIED VERTICALLY DOWNWARD ALONG ANY ONE FOOT (12-INCHES) OF ANY PRIMARY MEMBER (EXCLUDING DIAGONAL WIND BRACING, WHICH IS TREATED AS A 'STRUCTURAL MEMBER' UNDER 2006 AMENDMENT DEFINITIONS. D. MAXIMUM ENCLOSURE HEIGHT SHALL NOT EXCEED 20-FEET E. ALLOWABLE DEFLECTION OF 'L / 60% AS SPECIFIED IN TABLE %10.1, FOR NON -HIGH VELOCITY HURRICANE ZONES. F. CONTINUOUS LOAD PATH 15 PROVIDED, 2. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD): A. ALL EXTRUSIONS SHALL BE ALUMINUM ALLOY %005-T5 (NOTE THAT THE SPLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALLOY %061-T(o, IF THIS MATERIAL IS MORE READILY AVAILABLE TO THE CONTRACTOR) (SEE COMPONENT SHAPES AND SIZES AT RIGHT). B. FASTENERS SHALL BE ALUMINUM ALLOYS 2024-T4 4 701546, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL, OR 300-SERIES STAINLESS STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE APPROPRIATE MEANS FOR SEPARATION OF DISSIMILAR MATERIALS AS THEY ARE DEFINED IN SECTION 02003.8A. THE CONTRACTOR MAY IMPLEMENT ANY OF THE MEANS SPECIFIED IN THIS SECTION. ANY ALTERNATIVE MEANS MUST BE ACCOMPANIED BY A LETTER OF CERTIFICATION FROM THE PRODUCT'S MANUFACTURER (THIS LETTER MUST BE SIGNED AND SEALED BY A FLORIDA LICENSED STRUCTURAL ENGINEER), WHICH STATES THAT THEIR PRODUCT MEETS / EXCEEDS ALL OF THE REQUIREMENTS SPECIFIED IN THE ABOVE - LISTED SECTION. THIS LETTER SHALL ALSO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD FROM BD.Q., INC. C. SCREEN CLOTH SHALL BE VINYL COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 x 14 (5851. OPEN). 3. ALL FASTENERS THAT PASS THROUGH ANY EXTRUSION INTO CONCRETE, MASONRY, WOOD, STEEL, ALUMINUM OR ANOTHER EXTRUSION SHALL HAVE A 5/8-INCH DIAMETER WASHER, MINIMUM (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD), AND SHALL BE NO MORE THAN 18-INCHE6 CENTER - TO - CENTER SPACING. 4. ALL FASTENERS ADJACENT TO UPRIGHTS THAT DO NOT REQUIRE REINFORCING ANGLE CLIPS, SHALL BE PLACED WITHIN TWO (2) INCHES OF THAT UPRIGHT (TYP. FOR BOTH SIDES). 5. SCREEN DOOR(S) MAY BE LOCATED IN ANY SCREEN WALL PANEL, EXCEPT FOR THOSE THAT CONTAIN DIAGONAL WIND BRACING CK-BRACING'). ALL DOORS SHALL BE SELF -CLOSING AND SELF -LATCHING. DOORS INSTALLED IN AN ENCLOSURE THAT SURROUNDS A POOL / SPA SHALL HAVE DOOR LATCHES INSTALLED FIVE (5) FEET ABOVE THE FLOOR, MINIMUM. 6, COPIES OF THIS ENGINEERING SPECIFICATION / DESIGN DETAIL ARE TO ONLY BE CONSIDERED VALID FOR PERMITTING OR DESIGN CERTIFICATION PURPOSES WHEN ALL SHEETS OF ANY SUBMITTED SET BEARS THE ENGINEER'S ORIGINAL SIGNATURE (IN BLUE INK), UNDER HIS EMBOSSED SEAL. BD.Q., INC. SHALL NOT BE RESPONSIBLE FOR NON -ORIGINAL COPIES THAT ARE SUBMITTED, THAT HAVE ANY UNAUTHORIZED CHANGES, ALTERATIONS OR DELETIONS ON THEM. 7. THESE ENGINEERING DETAIL DRAWINGS ARE ONLY VALID IF THE DATE ACCOMPANYING THE ENGINEER'S ORIGINAL SIGNATURE 15 LESS THAN 90 DAYS OLD. NO BUILDING OFFICIAL OR BUILDING DEPARTMENT SHOULD ACCEPT COPIES THAT ARE OLDER THAN THIS, AND SHOULD REQUEST THE SUBMITTING CONTRACTOR OBTAIN UPDATED / CURRENT ENGINEERING. 8. ALL ENGINEERING SPECIFICATIONS AND DETAIL DRAWING CONTAINED WITHIN THIS ENGINEERING DOCUMENT ARE THE SOLE PROPERTY OF BD.Q., INC. ANY UNAUTHORIZED COPYING OR OTHER REPRODUCTION IN PART OR WHOLE OF THESE DOCUMENTS WILL NOT BE PERMITTED AND WILL BE PROSECUTED TO THE FULLEST EXTENT ALLOWED BY LAW, 9. THERE SHALL BE NO REDISTRIBUTION OF THESE ENGINEERING DOCUMENTS BY THE PERSON OR COMPANY THAT ORIGINALLY PURCHASED SIGNED AND SEALED COPIES FROM BD.Q., INC., WITHOUT EXPRESS WRITTEN AUTHORIZATION FROM BD.Q., INC., AND THE ENGINEER OF RECORD. WALL COLUMN SCHEDULE (ALLOW. COLUMN HEIGHTS VS. WALL PANEL WIDTH) U60 MAX. ALLOWABLE DEFLECTION (140 MPH, EXP. "C", 29 P.S.F. DESIGN LOAD) DIMENSION ICOLUMN GHT vs WALL PANEL WIDTH (DESIGN PRESSURE = 29 PSF) SIZE Tf Tw 8' 0" T 6" TO' 6' 6" 6' 0" 5' 6" 5' 0" 4' 6" 4' 0" 2x4 L .100 .045 l' O' T 3' 1' W 1' 9' 8' 1' 8' 6' 9' O' VW 10' 0' 2x5 L .116 .050 8' 9' 9' O' 9' 3' 9' 1' VIP 10' 4' 10' 11- 11' 6' 12' 2' 2X6 L .120 .050 Vol V 3' V l' 9' 11' 10' 5' 10' 10' 11' 4' 12' 0' 12' 9' IF 2X7 L .120 .067 V IV 101' 1 10' 5' 10' 10' 1113, II' 9' 12' 3' 1311, 13, 10, 2x8 L .224 .072 12' 0' 12' 4' 12' 9' 13' 3' VS' 14' 5- 15' 1' 15,101 16, 9' 2x9 -L(L) .209 .072 14' 5' 14' 11' 15' 6' 16' P 16' 8' Ill 4' 18131 19' 3' 20131 2x9 _L(H) .306 .082 Ill 9' 18' 5' 19' I' IV V 20' 1' 21' 5' 22' 6' 23' 8' 25' 2' 2x10 L 1 .389 .092 21' 2' 21' 9' 22' 1' 23' 5' 24' 4' 25' 4' 20 1' 28' 1' 29' 8' Tf COMPONENT 5HAFE5 AND 5P CIFIC IkFA�,Ziyj I'N ORDER To CRY �AR1aE O Tw .044 .040 .010 .010 -L -L o3° 2, 2, 2 I � 3 � 1x3O.B. 1x20.5. 2x2x.m93CUBE 2 x 3 'H° 3 x 3 W�DIAL. BRACING -- '� THE ACTUAL VALUES FOR 'Tf' (kANGE THICKNESS) AND 'Tw' (WEB THICKNESS) FOR THE VARIOUS SELF -MATING ('L°) SIZE SELF -MATING MATERIAL ARE INDICATED ON THE UPRIGHT HEIGHT AND BEAM SPAN TABLES. HOST STRUCTURE WITI STRUCTURAL GUTTER FLAT ROOF BEAM i J .1 N HOST STRUCTURE WITH STRUCTURAL GUTTER MANSARD ROOF BEAM SPAN i MANSARD BEAM SPANS ARE BASED _,rON A MAXIMUM SPLICE ANGLE OF 30° FOR HALF -MANSARD BEAM SPANS, USE VALUES SHOWN IN 'MANSARD BEAM SPAN TABLE (SAME MAX. SPLICE ANGLE (30°) APPLIES TO HALF -MANSARD BEAMS) HOST STRUCTURE WITH STRUCTURAL GUTTER f[�A�PEAK / GABLE ROOF BEAM SPAN BEAM SPANS AND COLUMN SIZES ON THIS SHEET ARE BASED ON SIMULTANEOUS LOADING, AS DEFINED IN TABLE 01002A, F.B.C. 2004, FOR 140 MPH WINDS, FOR EXPOSURE CATEGORY 'C' (28 P.S.F. WALLS, 8 P.SF. ROOF, FOR NON-HVHZ) FLAT (SIMPLE) ROOF BEAM SCHEDULE FOR FIAT BEAMS, U60 MAX. (140 MPH, EXPOS. -B-) SIZE DIMENSION ROOF PANEL WIDTH vs BEAM SPAN (FOR MAX. WALL HEIGHT OF 16' 0") Tf Tw 8' 0" T 6" 7' 0" 6' 6" 6' 0" 5' 6" 5' 0"16' 4' 0" 2x4 L .100 .045 13' 6' 13' 11' 14, 5' 15' 0' 15' 1' jr,, 3' fill, 19' 0' 2x5 L .116 .050 I6' 6' 16' II' 11' 1' 18' 3' 16' 11' 19' 9' 20' 8'23' P 2X6 L .120 .050 IT O' 11'1' 18' 2' 18' 10' 19' 1' 20' 5' 21' S' 23' V 2X7 L .120 .057 18' 6' M' 2' 1V 9' 20' 5' 21' 4' 22' 3' 23' 3' 25' 11' 2x8 L .224 .072 22'1' 23'3' 24' P 24' 11' 25' 11' 21'0' 28' 3'31' 5' 2x9 L (L) 209 .072 21'3' 26' 1' 29' P 30' P 31'3' 32' 1' 39' 2' , 31,11' 2x9 L (H) .306 .082 33'1' 34' 1' 35.9'31.1' 38. 40' 2' 41' 11' 46'6' 2x10 L .389 .092 39' 5' 40'8' 42' 1' 43'1' 45'2' 41' 1' 49' 2'54' 3' (1) REPRESENTS SPAN VALUES THAT ARE DEFLECTION -LIMITED BEAM SPAN CALCULATION NOTE: THE SPANS IN THESE TABLES ARE BASED ON BOTH THE H05T STRUCTURE MOUNTING POINT AND WALL HEIGHT BEING THE SAME MEASUREMENT MANSARD / CENTER PEAK (GABLE) ROOF BEAM SCHEDULE use MAX. (140 MPH, EXP. -C-) *THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL RISE OF 3' 0" (36")* SIZE ROOF PANEL WIDTH vs BEAM SPAN (FOR MAX. WALL HEIGHT OF 8' 0-) Tw 8'0" 7'6" T0" 6'6" 6'0" 5'6" S0" 4'6" N0" 2x5 L EDIMENSION .0502x6 L .050 Vol 10' 3' 12' 5' 14' 8' 2x7 L .120 .057 8' 2- 10' 0' II' 11- 13' 9' 15' 8- 18-0- 2x8 L .224 .072 12' W 13' 8' 15' 2' I6' 4' 18' 0' 19' 6' 21' 3' 233 3' 25' 4' 2x9 L (L) .209 .072 IV W 20' 8' 22' 0' 13' 5' 25' 0' 26' 6' 28' 5- 30' 5- 33' 0' 2x9 L (H) .306 .082 2T 8' 1 2V 0' 1 304' 31' II" 1 33' 6' 35' 5' 31' 5' 1 39'.9' 42' W 2x10 L .389 .092 34' 8' 1 36' 2' 31' 1' 1 39' 3' 41' 2' MANSARD / CENTER PEAK (GABLE) ROOF BEAM SCHEDULE U60 MAX. (140 MPH, EXP. 'C') *THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL RISE OF 3' 0" (36')* SIZE DIMENSION ROOF PAbfL WIDTH vs BEAM SPAN (FORJAX. WALL HEIGHT OF 12' 01 Tf Tw 8' 0" 7' 6" 7' 0" 6' 6" 6' 0" 5 6" 5' 0" 4' 6" 4' 0" 2x5 L .116 .050 2x6 L .120 .050 2x7 L .120 .057 VW 12' 2' 2x8 L .224 .072 10' 0- 12' 3' 14' 6' 16' 9' 19' 3' 21' 8' 2x9 L (L) .209 .072 14' 3' 15' 11' 11' 5' 1V 3' 21' 2' 23' 2' 25' 3' 216' 30' 2- 2x9 L (H) .306 .082 24' 3' 25' 6' 2T V 2V O' 30' 11' 32' 11' 35' 2' 31' 8' 40' 6 ' 2x10 L .389 .092 32' 0' 33' T 35- 2' 31' 0' 39' 0' 41' 2' 43' l' 4b' 3' 49' 5' MANSARD / CENTER PEAK (GABLE) ROOF BEAM SCHEDULE U60 MAX (140 MPH, W. -cl *THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL RISE OF 3' 0" (36")* SIZE DIMENSION ROOF PANEL WIDTH vs BEAM SPAN (FOR MAX. WALL HEIGHT OF 1& 01 Tf Tw 8' 0" 7' 6" 7' 0" 66" 6' 0" 6 6" 5' 0" 4' 6" NO" 2x7 L .120 .057 2x8 L .224 .072 I0' S' 14' 2' IT 5' 2x9 L (L) .209 .072 V 8' 11' 5'_ _13' 11' 16' 4' W 11' 21' 4' 24' 2- 2T 2- _ 2x9 L (H) .306 .082 20' 3' 22' 0' 23' W 25' V 21' 11' 30' 1- 32' b' 35' 3' 38' 4' 2x10 L 1 .389 .092 29' I' 306' 32' 1' 34' 5' 30 1' BV O' 41' 6' 44' S' 4l' 8' MANSARD BEAM SPANS OF LESS THAN 8' 0' ARE OMITTED FROM THIS TABLE is O U J a O z aw �- - u') 0 wa) a LO CD Z in S zd to J 5 wLy '" o¢9 �LL.z� J U Q L U- >- _ w OOZI� uw O CD O Z z C9 = z CD oZ�W L� w (!) oz�g o ww~LL z OW= ZF-3:CIO, LL iV ILL j O = U ®0 W Z 0 O Ltl U (L _ C14 a 0W W _ Cn LLJ o P 0-- C0. a- VIm��`w�z Z jQ�a �H I � 0 LL. ado s 0 �% �uio�dIrw m 2 �N3 6 V c� °(71 w Ch a u. UP TO IV BEAM SPAN IV TO 24' BEAM SPAN 2 4' TO 32' BEAM SPAN 32' TO 40' BEAM SPAN O-INDICATES WALL PANEL THAT SHALL HAVE DIAGONAL "K"-BRACING IN IT UP TO 0'.WALL HGHT EXIST. HOST STRUCTURE EXIST. H05T STRUCTURE NUMBER OF PANELS r VARIES S' TO 12' WALL HGHT Il- ,■■■I in S ■„\ lilk E m m m : 1611 lo 4 lvrl� EXIST. HOST STRUCTURE TOTAL NO. OF BAYS VARIES THREE (3) BAYS ON EACH END OF OUTER -MOST WALL SHALL HAVE bIAG. 6RACIN6 TOTAL NO, OF BAYS VARIES THREE (3) BAYS ON EACH END OF OUTER -MOST PANELS AND TWO (2) PANELS IN SECOND OUTER -MOST ROW OF PANELS SHALL HAVE THE DIAGONAL BRACING (AS SHOM) THE BRACING SCHEMATICS SHOWN ABOVE ARE THE SAME BRACING CONFIGURATION, REGARDLESS OF -ROOF TYPE (MANSARD, PEAK, DOME, FLAT, ETC.) DESIGN NOTES: ALL DIAGONAL BRACING, USED EITHER IN THE ROOF _ . OR AS 'K'-BRACING IN THE WALLS SHALL BE 2' x 2' x .093 WALL THICKNESS TUBE, AND SHALL BE CUT TO FIT SNUG, WITH NO PLAY OR SHIFT IN THE BRACING. - SEE DETAILS AT RIGHT FOR CONNECTION SPECIFICATIONS DESIGN NOTE: ALL THRU-BOLTS PASSING THROUGH ANY ALUMINUM MATL. WITH A WALL THICKNESS LESS THAN .0130, SHALL HAVE A Ilia -INCH (OUTSIDE DIA.) FENDER WASHER (SEE GENERAL NOTE #2 ON SHEET 12 REGARDING SEPARATION OF D1551MILAR METALS). THE CONTRACTORS MAY, IF THEY CHOOSE, INSTALL THE ANGLE CLIPS FOR THE DIAGONAL TUBE BRACING (WHERE IT ATTACHES TO THE SELF - MATING SCREEN ROOF BEAMS) WITH THE THRU-BOLTS ONLY PA56ING THROUGH ONE HALF OF THE BEAM. THIS 15 A STRUCTURALLY ADEQUATE ALTEF�NATIVE, AND WILL PERMIT INSTALLATION OF THESE ANGLE CLIPS IN THEIR SHOP, DURING FABRICATION (PO5515LY SAVING TIME DURING INSTALLATION IN THE FIELD). 2 x 2 x 1/8' ANGLE CLIP, CUT AT A 45' (+/-) ANGLE AND ATTACHED TO THE 2 x 3 x .010 EVE RAIL WITH ONE (1) 1/4' DIA. THRU-BOLT, WITH FENDER WASHER (SEE DESIGN NOTE ABOVE 2 x 3 x .010 SCREEN ROOF PURLIN N NOTE: ALL DIAGONAL BRACING SHALL BE ATTACHED VIA THE 2 x 2 x 14" ANGLE CLIPS, AS SHOWN, AND SHALL HAVE EACH END ATTACHED TO EITHER THE SCREEN ROOF BEAM OR TO THE EVE RAIL..NO DIAGONAL BRACING SHALL BE ATTACHED TO ANY OF THE ROOF PURLINS 2 x 3 x .010 SCREEN ROOF PURLIN 2 x SMB SCREEN ROOF BEAM (TYP) X PLANS ANDALL PROPOSED WORK BJECT TO ANY CORRECTIONS ED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPUCABLE CODES. SPLICE JOINT —2 x 2 x fi8' ANGLE CLIP, CUT AT A 45' (+/-) ANGLE AND — — ATTACHED TO THE SCREEN — — ROOF BEAM WITH ONE (1) 1i4' DIA. THRU-BOLT, WITH ® FENDER WASHER (SEE DESIGN NOTE ABOVE TYPICAL ANGLE ARTICULATION TO CREATE UPWARD ANGLE O [DIA60NAL ROOF 5 ACING [DETAIL USE UJITH ALL00"Y &(D"A' 0" t5l - T 5 0`4 N L Y uj r a' 0 0 o can ao aw �o Lo LOU) LLI — Lo o co = w c�o w O O L Jo0L J U>�u Q LL- UD i O02w zoz owz inzF_W W 5 Lu C� 0zm� 0 WWHw 'r o xw LL =. z I— � co L— fV O �' _ z w p to LU Z Z® O W v M OX�XLu Cn W W 0 O co - co w � ci 0 Lu � a: N Z¢�MON¢ �o�Z0 zpoW� uio ¢ww CLi o� oEj � ) 04 z LLI a w SEAM 5PLIGE 5F CIFICATION5 DIA ONAL WALL BRAGING3 CK' BRACING) DETAIL M4 TEK SCREW (TYPICAL) A 101 0 O O O O O l O 0 O V- 0 0 0 0 0 O- �/ SPLICE PLATE MATERIAL -' \ 5HALL BE 1/4' THICK (MIN.) AND BE EITHER 06005-T5 OR %06146 ALLOY BEAM 5PLICE DETAIL (2 x S 5EAM5 AND LARGER) *(Mu5T USE 1/4" THICK GUSSET PLATE)* O `0 0 0 0 0-' O 0 0 O 0 0 0 �0 +14 TEK SCREW (TYPICAL) _ SPLICE PLATE MATERIAL SHALL BE 3/16' THICK (MIN.) AND BE EITHER "600545 OR 06061-T6 ALLOY SEAM SPLICE DETAIL. (2 x I BEAMS AND SMALLER) *(MUST USE 3/16" THICK GUSSET PLATE)* T E TYPICAL 3/16 OR 1/4' THICK SPLICE PLAT SPLICE PLATE TOLERANCE NOTE: ALL SPLICE PLATES (ALUMINUM ALLOY %M-T5 or %061-%) SHALL BE CUT TO BE 40DOO / -0.0625, AS INDICATED IN THE SCHEMATIC DRAWING AT LEFT SAME AS 'A' BEL( JUST REVERSED 3x3x210H CORNER UPRIGHT NAN 4-INCH x 4-INCH x .010 PLATE, WITH (4) M2 TEKS IN THE 3 x 3, (3) 012 TEKS IN THE BOTTOM I x 2 AND (3) 012 TEK IN THE 2 x 2 BRACI 3 x 3 'H' COLUMN 2x2x,0133T DIAGONAL Bf I x 2 BOTTOM SCREEN FRAh 2x3x.010ROOF PURL IN Ix2013TOP SCREEN FRAME 2 x 2 x .093 TUBE DIAGONAL BRACE 3 x 3 x -010 CHAIR RAIL 2 x 2 x .093 TUBE - DIAGONAL BRACE DETAIL. 11,4" (OUT50D ) (IN51PE) I x 2 OB BOTTOM SCREEN FRAME 3 'H' CORNER ILUMN 2x2x0133TUBE DIAGONAL BRACE I x 2 BOTTOM SCREEN FRAME I -INCH x 3-INCH x 2133 ANGLE, CUT 4- INCHES LONG, WITH (3) 12 TEKS IN THE 3 x 3, (3)12 TEKS IN THE BOTTOM I x 2 AND (3) 92 TEKS IN THE 2 x 2 BRACE 2 x SMB SCREEN ROOF BEAM • - � i.` Yam}-, -r.; ^�� ..3,r �,t -� � • 2 x 2 x .093 TUBE - DIAGONAL BRACE 3x3x.010 CHAIR RAIL 2x2x2133TUBE— DIAGONAL BRACE 2 x 5 SMB UPRIGHT (MINIMUM SIZE) 2 x 2 x OB3 TUBE - DIAGONAL BRACE 2 x 5 SMB UPRIGHT (MINIMUM SIZE) 3 x 3 x .010 CHAIR RAIL 2x2x033TUBE - DIAGONAL BRACE 11511 J w 0 cn w DETAIL ? UO- LL O0I g w 4-INCH x 10-INCH x CD z— S 0 w Z .010 PLATE, WITH (1) *12 TEKS IN THE SMB 0 � z i=-` w ui w W 0 0 UPRIGHT, (3) *12 TEKS ° ° ° IN THE CHAIR RAIL m O0 w m o 0 AND (3) "12 TEKS IN EACH 2 2 BRACE w F w ~ u x 0 0 00 Z��c wLLI LL 0 0 ° 0 3x3x.010 0 0 CHAIR RAIL LL- O j OM Zwo� w�ILL ZO / ` THESE PD�s AND ALL PROPOSED WORK Ld.l ¢ w (- ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT CL CU W W MAY BE NECESSARY IN ORDER TO ' OMPIX WITH ALL APPLICABLE CODES. J _ cn LU ®F- a- I -INCH x 3-INCH x V33 ANGLE, CUT 4- INCHES LONG, WITH ° (3) M2 TEKS IN THE _ ° SMB UPRIGHT AND ° l3) "12 TEKS IN THE 2 x 2 BRACE 3x3x.010 o CHAIR RAIL ° o I -INCH x 3-INCH x 293 ANGLE, CUT 4- INCHES LONG, WITH (3) 12 TEKS IN THE SMB UPRIGHT. AND TEKS IN THE 2 x 2 BRACE (IN61DE) ' Abbreviation Legend: "SYMBOLS SHOWN HEREON ARE NOT TO SCALE �} S 89'59'49" E 10 P.C.' —POINT OF CURVATURE (P) —PLAT; PLANNED - 28.27' (P)(M) N W BOUNDARY SURF P.R.C. — POINT OF REVERSE CURVATURE (M) — MEASURED / ! Legal Description P.C.G — POINT OF COMPOUND CURVATURE (C) — CALCULATED -- - -- P.T. — POINT OF TANGENCY (E) — ENGINEERING PLAN Ale SETBACK - Lot 69 BLOCK D of LAKES AT PGA VILLAGE, per the plat thereof, as recorded P.I. — POINT OF INTERSECTION (A) — ACTUAL 9V! / ;j in Map Book 43, pages 32, 32A through 32F of the Public Records of St. Lucie P.C.P. - PERMANENT CONTROL POINT - (N.R.) - NON -RADIAL �����-� {:.-� t® County, Florida. P.O.POINT ON LINE C.L.F.- CHAIN LINK FENCE + P.R.M. - PERMANENT REFERENCE MONUMENT W.F. - WOOD FENCE SIDES / / ;' _ Survey Notes: C.B. - CHORD BEARING C A G - CURB & GUTTER �+ p+,eeRp� IgDpyES , 4.^lii P'hE!rP..�0.s C.M. —CONCRETE MONUMENT CAN —CABLE' TELEVISION RISER t� ppa�yy L � , 1. 'NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL RB. - PLAT BOOK T - TELEPHONE RISER�3"ebal, - - - - / / ' ' OF A FLORIDA LICENSED SURVEYOR AND MAPPER'. Pg. — PAGE TRANS — TRANSFORMER PADdSti�Aa ' N-R. —NQN—RADIAL L.P. —LIGHT POLE � - 2. BEARINGS SHOWN HEREON ARE BASED ON THE NORTH LINE OF LOT 69 RAD. - RADIAL p•p, _ ppyy� pp� T CHO -- _ �, BLOCK D LAKES AT PGA VILLAGE AS RECORDED PLAT BOOK 43, PAGES 32, R. -RADIUS NG -NATURAL GROUND AS �� ^ 32A THROUGH 32F OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY FLORIDA L — ARC LENGTH LC.V. — IRRIGATION CONTROL s, AS BEINGS 89'59'49" E (PER THE PLAT THEREOF). 0 — DELTA C.O. — CLEANOUT `� '°'� ++' R-P. — RADIUS POINT S/W - FDEWALK `Q1 / - i :: ' � I _ 3. THE "LEGAL DESCRIPTION' HEREON WAS PREPARED BY THE SURVEYOR V PER THE CUENT'S REQUEST. R/W — RIGHT—OF—WAY EJ.B. — ELECTRIC + 0 q - CENTER LINE JuNc noN Box �i�rL / '` to 4. THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT EL - ELEVATION SO. FT. - SQUARE FEET p�. - -` OR OPINION OF TITLE NO INSTRUMENTS OF RECORD REFLECTING A/C - AIR CONDITIONER W.M. - WATER METER � / j.`i'\ EASEMENTS, RIGHTS -OF -WAY, AND/OR OWNERSHIP WERE FURNISHED TO TYP. — TYPICAL F.H. — FIRE HYDRANT THIS SURVEYOR EXCEPT AS NOTED. CONC. - CONCRETE N & D - NAIL AND DISC / / - UTILITY EASEMENT B.M. - BENCH MARK 5. ELEVATIONS BASED ON SITE BENCHMARKS PROVIDED BUILDER AS U.E COMMON AREA SET BY OTHERS AS SHOWN ON APPROVED ENGINEERING ASS -GUILTS. D.E. - DRAINAGE EASEMENT PVMT. - PAVEMENT r LAKES AT P.G.A. VILLAGE D/U -DRAINAGE AND UTILITY EASEMENT F.B. - FIELD BOOK PLAT BOOK 43 G. ELEVATIONS SHOWN HEREON WITH AN '(E)" ARE PROPOSED PER F.F- — FINISHED FLOOR ' M.H. — MANHOLE PGS. 32, 32A-F CONSTRUCTION PLANS PREPARED BY OTHERS AND FURNISHED BY THE BSL — BUILDING SETBACK LINE FND FOUND 12' I.I.E./ / �� --. `y CLIENT ' C.B.S. — CONCRETE BLOCK STRUCTURE REC — RECOVERED �F.. �\, 1 ? 7. NO. UNDERGROUND INSTALLATIONS OR VISIBLE IMPROVEMENTS ON SITE OR BEYOND PROPERTY LINES HAVE BEEN LOCATED EXCEPT THOSE SHOWN HEREON.8. BUILDING TIES SHOWN HEREON ESTABLISHED ON THE FINISHED LOT 70 / 61 / O FOUNDATION AND EXCLUDE EXTERIOR STUCCO AND BRICK BEYOND THE BLOCK D 2 FOUNDATION. LAKES AT P.G.A. VILLAGE / Q I `� '� PLAT BOOK 43 ?�.' 00 9. PROPOSED FINISHED FLOORS ARE PER ENGINEERING PLANS PROVIDED PGS. 3$ 32A-F /,ti`/ �'� - BY LBFH INC, AND DATED 04/28/04. W / 3 \ bg. - RESIDENCE ADDRESS : 9152 Short Chip Circle LOT 69 /� INTERNAL BUILDING SETBACKS: / FRONT- 20' (SIDE LOAD GARAGE) RESIDENCE# 9152 t 44.9' FRONT- 25 (FRONT LOAD GARAGE) / REAR= 15' 1 STORY C.B.S. i TIE PROP 30' REAR= 3• (WITH PATIO/POOL DECK/ SCREEN) \ COVERED SIDE- 6' /N F.F. = 28.90' r LOT GRADING TYPE "A' ENTRY F -_ X PROPa05ED FO.F. 28 30' C.V. HIGH POINT OF ROAD = 26.56' e / COO6MODEL "RIVIERA" W. ,i b 2' VALLEY GUTTER COLUMN �o p/ 3.5'x3.5' v. CONC. PAD Survey: riicafioi: SET I.R. & CAP I hereby certify that the attached "BOUNDARY SURVEY of the R 55.00. i, O ` W LB 143 hereon -described property is true and -corroat to the besi of my C, / / Certified To: `1 knowledge, Information and belief as Frepa�d under my direction y� L=.�' \CN1�.�All CORNERS) I Michael Brachfleld and Jeffrey Berman on January 23, 2006. 1 further ce (TYPICAL FOR rtify thGt thl9 "Bo;JNDA?Y SURVEY, xx e \ ' CP 1 1 Ticor Title Insurance Company D/8/A meets the minimum technical standards set fi.; th Sr. rule 61g17-6 , a hrO �45� � mN 129.5� Chelsea Title Company of the Florida Administrative Code. S CENTERLINE R=100.00' y n �pl (p)(M I �: Q.C.P_/P.C. L=59.204 6 E W/rFK N & D &-33-55'11" SHORT CHIP ^ •575 LB# 7143 (C) CIRCLE I` r Chelsea Fie# 05-1642Y 1 R �C0 Ralph A Mato, P.S.M. / •r1� VARIES ) T Professional Surveyor and Mapper LOT 68 Florida Registration No. 6025 UNDER CONSTRUCTION) COC BLOCK D R=100.0 ' LAKES AT P.G.A. VILLAGE L=z7.ss' MAILBOX I PLAT BOOK 43 REVl570N �15 52'00" t6 PGS. 32, 32A-F Engineers (G) Planners s �. Landscape Architects FINAL SURVEY JTF 1 /z3/os R=100.00' �� Surveyors AS —BUILT SURVEY JTF 4/22/05 R-100.00' L=57.15' 10' U.E. L=157.08' A-32'4435" Construction Management STAKE OUT DK 4/12/OS C90*0 000 " 1 (C) tv. w w c p h e n g i v e e r s. c 0 m rrF 1 /21 /05 CB=N44'59'49"W CENTERLINE / 500 WestP411on Street, Sanford, FL 32771 P.O. Box 2808, Sanford, A 32771-280g PLOT PLAN (P) P.C.P./P.C. Phone 40Z322.6941 Fax: 407330.0639 Certificate of Authorization No. 7I� W PKN&D DESIGN NOTES: _ 1. ALL DIAGONAL BRACING SHOWN IN BOTH THE ROOF AND WALLS SHALL 5E 2_ x 2 x .093 TUBE MATERIAL. 2. 18 x 14 MESH SCREEN IS THE MAXIMUM ALLOWABLE DEN61TY FOR THIS ENCLOSURE'S DESIGN. 3. DOOR(S) MAY 5E PLACED INTO ANY SCREEN WALL PANEL EXCEPT FOR THOSE THAT CONTAIN DIAGONAL BRACING. 9' 0' HEIGHT � I x 3 THIS PANEL IS BEING _ INSTALLED UNDER THE x x EXIST. HOUSE ROOF _0 x X x I x 3 Ix3 N PIONEER SCREEN CO., 11 SCREEN ROOF / ALUM. ROOF ENCLOSURE FOR: LABERGE RESIDENCE 9152 SNORT CHIP CIR. PORT ST. LUCIE, FLORIDA z w Q � x �9 m x F- N N / / I OVERALL- DESIGN COMPLIES WITH THE 200(o AMENDMENTS TO THE F.B.C. 2004 BUILDING CODE, FOR 140 MPH WIND LOAD (3-6ECOND GUST), FOR EXP. CAT. "C" (NON-H.V.H.Z.). THIS SYMBOL REPRESENTS DIACONAL ® WIND BRACING (IN BOTH THE ROOF AND WALLS), 2 x 2 x .Oe3 TUBE MAIL. 3-INCH INSULAT-4D ALUMINUM ROOF SYSTEM WITH 024 SKINS AND 1-1-15 DENSITY CORE MATERIAL (TYP) NOTE THAT THE CARRIER BEAM PASSES BENEATH THE SOFMT E IS ATTACHED TO THE C.5.5. WALL BENEATH THE FASCIA / SOFFIT HOST FASCIA lx2 2 6' 8' 618. i 8' 0 THIS SYMBOL REPRESENTS BEAM SPLICE LOCATIONS 14' ' CARR. BM. SPAN 2' 0' ROOF WIDTH � U I � 2 x 10 CARRIER BEAM (CONT) N � I � (018. I x 2 x Ol0 r d � m p R I x = cn ►- x N N x 100 l \ x ,l I 'no x m x m I x 2 x x xN x x N (TYP) N N N 3 x 3 x 31 lx2 6 8' I 6 8'y 8' I 6 8' _ I_ 6 8' I x 3 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. lu L CIE UN QBUILDING DIVISION REVIEWED @ RFOR IAI�ICE EVIEWS DATE 'FrLAIU9 XWD PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE u) /� �❑ c0 00 N I( )1 ;_ co JGo O LL o 0 o ap°(OZN- �1�cqa W J 0 ❑ n z d ow t ©ZQ.o U T 0 ❑ no�J ° 4J cq W TC0� ° noZ u.w�z ❑ T W moo 0 U) 0)LL "PAE3RIGATION / INSTALLATION REQUIRED GUIDELINES: NOTE: ANY J055 THAT REQUIRE SITE -SPECIFIC DESIGN / ENGINEERING MU5T BE 5U5MITTED TO THE ENGINEER OF RECORD FOR SUCH DESIGN CON511DERATION PRIOR TO THE JOB BEING PERMITTED, FABRICATED OR INSTALLED. LEAD-TIMES FOR SUCH WORK WILL DEPEND ON OUR CURRENT WORK LOAD AT ANY GIVEN TIME. THE ITEMS BELOW ARE NOT PERMITTED ON ANY ENCL05URE WITHOUT 51TE-5PECIFIC DESIGN 4 AUTHORIZATION FROM THE ENGINEER OF RECORD. I. NO SCREEN ROOF BEAMS SHALL BE LOCATED WITHIN 12-INCHES OF ANY OUTSIDE CORNER OF ANY WALL, FASCIA OR STRUCTURAL GUTTER. 2. NO CABLE BRACING SHALL BE USED ON ANY ENCLOSURE AT ANY TIME FOR THE RESISTANCE OF ANY IMPOSED DESIGN LOADING. 3. THERE SHALL BE NO SUBSTITUTION OF EITHER CONCRETE ANCHOR TYPE OR MANUFACTURER OTHER THAN THOSE SPECIFIED ON THESE ENGINEERED DESIGN DRAWINGS. 4. THERE SHALL BE NO SCREENING UTILIZED THAT 15 FINER THAN 18 x, 14 MESH SCREEN WITHOUT SITE -SPECIFIC DESIGN (THAT SHALL BE DONE PRIOR TO THE JOB BEING FABRICATED OR INSTALLED) WITH J05 DRAWINGS BEARING THE ENGINEER OF RECORDS ORIGINAL SIGNATURE (IN BLUE INK) UNDER HIS EMBOSSED SEAL. 5. ALL SCREEN ROOF ENCLOSURES MUST BE POSITIONED ON THE EDGES OF THE CONCRETE DECK 50 THAT THE OUTER SURFACE OF THE -SCREEN FRAME 15 NO LESS THAT 2 3/4 — INCHES IN FROM THE EDGE, TO CREATE PROPER EDGE DISTANCE FOR THE SPECIFIED CONCRETE ANCHORS AT THE BASE. OF EACH COLUMN. 6. ALL ROOF PURLINS IN'THE ROOF AND CHAIR RAILS IN THE WALLS SHALL NOT EXCEED 8-FEET CENTER — TO - CENTER SPACING (SEE APPROPRIATE DETAILS ON OTHER SHEETS OF THIS DRAWING FOR SPECIFIED MATERIAL 617ES REQUIRED FOR ANY GIVEN APPLICATION. 1. NO SCREEN ROOF ENCLOSURE SHALL BE INSTALLED UTILIZING SEVEN-INCH STRUCTURAL GUTTER, AS IT IS NOT PERMITTED, OR STRUCTURALLY ADEQUATE UNDER THIS ENGINEERING. THE ITEMS BELOW MUST BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO MEASURING 4 LAYOUT, FABRICATION OR INSTALLATION FOR THE REQUIRED 51TE-5PECIFIG DESIGN. I. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES ROOF BEAMS THAT EXCEED 40-FEE7 IN SPAN, AT ANY POINT ON THE ENCLOSURE. 2. ANY SCREEN ROOF ENCLOSURE THAT UTILIZES WALL COLUMNS (UPRIGHTS) THAT EXCEED 12-FEET IN HEIGHT AT ANY POINT ON THE ENCLOSURE. 3. ANY ENCLOSURE THAT UTILIZES ANY CARRIER BEAM (A BEAM THAT ACTS AS SUPPORT FOR ANY OTHER SCREEN ROOF BEAM) AT ANY POINT ON THE ENCLOLSURE. NO CARRIER BEAM SHALL BE PERMITTED TO BE MOUNTED TO THE FASCIA OF ANY HOST STRUCTURE (AS PRIMARY SUPPORT). 4. INSTALLATION OF ANY SCREEN ROOF ENCLOSURE ON AN EXISTING HOUSE FASCIA WHERE THE OVERHANG EXCEEDS 2-FEET. NOTE THAT IF THE EXISTING RESIDENCE WAS CONSTRUCTED UNDER ANY BUILDING CODE PRIOR TO F.B.C. 2001, THE JOB MAY REQUIRE FOURTH -WALL TYPE CONS% AS THERE 18 NO WAY TO CERTIFY THE ABILITY OF A HOST STRUCTURE THAT WAS ONLY BUILT TO WITH- STAND 110 MPH WIND LOADS OR LESS, (AS WAS REQUIRED UNDER PREVIOUS BUILDING CODES) TO RESIST THE IMPOSED LOADS OF AN ENCLOSURE THAT. IS DESIGNED TO WITHSTAND THE LOADS IMPOSED UNDER THE 140 MPH WIND LOAD SPECIFIED.IN THE CURRENT BUILDING CODE. IICONNECTION NOTE: ALL FRAMING MEMBERS ON ANY ENCLOSURE.THAT UTILIZE SNAP OR LAP JOINT IN THEM SHALL HAVE #12 TEKS INSTALLED THRU THE SNAP OR LAP CONNECTION AT 18 INCHES ON CNTR. (TYP). THESE TEK SCREWS ARE TO BE PLACED ON 50TH EDGES OF THE UPRIGHT (BOTH THE INNER AND THE OUTER EDGE) IN ALL CASES. THIS SPECIFICATION APPLIES TO UPRIGHTS AND BEAMS BOTH. V MIINMUM TOOTER TAE3LE5 NO MAX. BM. DOTER SPAN V x 8' WITH lU 050 CONT. UP.TO 38' Vx12'WITH (1) P50 CONT. UP TO 41' 10'x12°WITH (1) SO CONT. UP TO 48' 12' x 12' WITH (2) F50 CONT Up TD 55' ISOLATED MAX. BM. FOOTER(l) SPAN 12' x 12' WITH (2) SO CONT. UP TO 30' 12, x 16' WITH 31' TO 39' (2) SO CONT. 14' x 16' WITH (2) 050 CONT. 40' TO 44' 16' x 16' WITH 44' TO 52' (2) 05� CONT. IF A J05 EXCEEDS THESE PARAMETERS, THE FOUNDATION MST EE SITE-SF'ECIFICAI_LY DESIGNED EY THE ENGINEER MONOLITHIC FTG. LOAD CAPACITIES ARE BASED ON A MIN, OF 3 FEET OF CCNT. CONCRETE, 2,500 PSI MINIMUM, W/ WIRE OR FIBERMESH REINFORCEMENT (s)16OLATED FOOTERS MAY BE USED ON EDGE OF EXIST, CONC, SLAB OR UNDERNEATH THE PERIMETER OF BRICK PAVER DECK (ALL SIDES) THE ENGINEER OF RECORD WILL NOT BE ABLE TO CERTIFY THE STRUCTURAL INTEGRITY OF ANY EX16TINC5 CONCRETE DECK / FOOTINGS THAT WERE INSTALLED WITHOUT PERMITS, AS THERE WOULD BE NO RECORDS TO VERIFY CONCRETE THICKNESS', TOOTER SIZES AND THE SIZE AND QUANTITY OF STEEL RE -BARS THAT WOULD BE REQUIRED UNDER THE CURRENT BUILDING CODE STANDARDS. SCREW SPACING AND EDGE DISTANCE SPEC.'5 THIS TABLE IS BASED ON THE PROPERTIES OF C-1022 LOW CARBON STEEL SMS AND SELF -DRILLING (TEK) SCREWS, WHICH ARE AN INDUSTRY STANDARD SCREW. SCREW 51ZE NOMINAL SCREW DIAHETER (IN.) MIN. EDGE DISTANCE MIN. CENTER -TO - CENTER DISTANCE 08 0.156 5/16' 1/I(0° #i0 0.188 3/8, 1/2' #12 0.219 1/2' 5/8' *14 0.250 5/8' 3/4' INTERNAL CONNECTION SPECIFICATION (UTILIZING SCREW BOSSES) ALL INTERNAL CONNECTIONS UTILIZING THE EXTRUDED SCREW BOSSES SHALL HAVE 1110 51-15 SCREWS, WITH A MINIMUM EMBEDMENT INTO THE SCREW BOSS OF 1 3/4" (UNLE55 OTHERWISE SPECIFIED ON ANY CONNECTION DETAIL). ALL SCREW 505SE5 IN A GIVEN EXTRUSION MUST BE FILLED (EXAMPLE: THE 3 x 3 x .010 CHAIR RAIL (MINIMUM SIZE) THAT HAS SIX SCREW BOSSES, MUST HAVE SIX OF THESE 010 SMS SCREWS INSTALLED AT EACH END OF THAT COMPONENT,,AT EACH CONNECTION). SCREEN PANEL INSTALLATION SPECIFICATION: PLEASE NOTE THAT ALL SCREEN PANEL OPENINGS (BOTH ROOF AND WALLS) SHALL BE INSTALLED ON ALL FOUR SIDES WITH SPLINE (INDEP- ENDANT OF ALL SURROUNDING PANELS). THE ONLY FRAMING COMPONENTS THAT ARE NOT REQUIRED TO HAVE SPLINE INSTALLED IN THEM ARE ALL OF THE DIAGONAL WALL AND ROOF BRACING. CONCRETE ANCHOR SPECIFICATIONS: ull 0. ALL CONCRETE ANCHORS SPECIFIED ON THIS DETAIL 'RED � d SHEET ARE MANUFACTURED BY HEAD' ANCHORING SYSTEMS, AS ALL LOAD CAPABILITIES ARE BASED ON d TEST DATA FURNISHED BY RED HEAD IN THEIR PRODUCT AND RESOURCE BOOK. NO SUBSTITUTIONS OF ANY OTHER MANUFACTURER'S CONCRETE ANCHORS IS PERMITTED WITHOUT SUBMITTAL OF THE COMPANY'S TEST DATA (TO VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN, SIGNED AND SEALED LETTER OF AUTHORIZATION FROM THE ENGINEER OF RECORD. ANY UNAUTHORIZED ANCHOR SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH THIS DESIGN. THE ANCHORS TO BE USED FOR APPLICATIONS cn u�3 t SPECIFIED IN THIS ENGINEERING DESIGN PLAN ARE AS U. FOLLOWS: 1/4' DIA FASTENERS: RED HEAD ITW TAPCON (SEE INDIVIDUAL DETAILS Q 0 �- FOR MINIMUM EMBEDMENT DEPTH INTO CONCRETE) y � `°e 3/8' DIA. FASTENERS: 3/8' TRU BOLT WEDGE ANCHOR (SEE INDIVIDUAL QUANTITY w ->,I 112 a001 DETAILS FOR OF FASTENERS NEEDED) 0 (MINIMUM EMBEDMENT SHALL BE 3' INTO CONCRETErL SPECIFIED � UNLESS OTHERWISE IN ANY DETAIL) 3/5' Lu LARGE DIAMETER TAPCON (LOT) (SEE INDIVIDUAL Im DETAILS FOR QUANTITY OF FASTENERS NEEDED) ® a 3 (MINIMUM EMBEDMENT SHALL BE 2112' INTO CONCRETE o UNLF-55 OTHERWISE SPECIFIED IN ANY DETAIL) ® Lu 8 QESIGN DISCLAIMER FOR BRICK PAVER INSTALLATION: FOR INSTALLATION ON A BRICK PAVER DECK, THE ONLY FASTENERS, THAT WILL MEET THE DESIGN CRITERIA INDICATED WITHIN THESE DESIGN SPEC.'S �. >, ARE THE RED HEAD TRU BOLT WEDGE ANCHOR (3/5' x I'), WHICH BASED ON 1/8' ANGLE, I x 2 0.5.,.21/9' THICK BRICK PAVER AND A MAXIMUM MORTAR o zi =LLJ BED THICKNESS OF 3/4'. THIS SCENARIO WILL STILL MEET THE MINIMUM W 0 co FASTENER EMBEDMENT. IF ANY OF THESE CONTRIBUTING FACTORS EXCEED THE DIMENSIONAL BREAKDOWN INDICATED, THE JOB MUST BE PRESENTED � 0 TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC ANCHORING DESIGN. uj � co L w EXIST. HOUSE FASCIA NOTES: 1 CL IT SHALL BE THE RESPONSIBILITY OF THE INSTALLING a. CONTRACTOR TO INSPECT AND INSURE THE CONDITION �. OF THE EXISTING FASCIA, TO DETERMINE IF IT IS IN GOOD ENOUGH CONDITION TO SUPPORT THE PROPOSED SCREEN �- ENCLOSURE (PRIOR TO ITS INSTALLATION) v� , > s THERE IS NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IN THIS ENGINEERING DESIGN DOCUMENT REGARDING THE ABILITY OF ANY HOST STRUCTURE TO RESIST THE BUILDING CODE SPECIFIED DESIGN LOADS IMPOSED BY ANY PROPOSED SCREEN ENCLOSURE. SUCH CERTIFICATION WILL BE DEPENDENT ON AVAILABILITY OF ORIGINAL DE516N AND CONSTRUCTION DOCUMENTS, AS WELL AS ORIGINAL PERMIT AND INSPECTION RECORDS FOR THE HOST STRUCTURE. CERTIFICATION OF THE HOST STRUCTURE, IF IT 15 REQUIRED, WILL ULTIMATELY BE POSSIBLE ONLY IF THESE RECORDS CONTAIN ALL THE INFORMATION NEEDED BY THE ENGINEER TO PERFORM ALL OF THE NECESSARY ANALYSIS TO DETERMINE IF SUCH CERTIFICATION 15 EVEN POSSIBLE. F=NERAL N®TE5 AND pE51GN PARAMETERS: I. THE OVERALL DESIGN COMPLIES WITH THE 2006 AMENDMENT TO THE FLORIDA BUILDING CODE 2004 (CHAPTER 16-AND 20), AND 15 BASED ON THE FOLLOWING PARAMETERS: - A. WIND SPEED: 140 M.P.H., 3-SECOND GUST B. EXPOSURE CATEGORY 'C' (NON-HVHZ ONLY) C. DESIGN PRESSURES AS FOLLOWS: a) SIMULTANEOUS WIND LOADING e 8 P.SR FOR SCREEN ROOF AMC) 29 F.S.P. FOR SCREEN WALLS b) 300 LB LOAD APPLIED VERTICALLY DOWNWARD ALONG ANY ONE FOOT (12-INCHES) OF ANY PRIMARY MEMBER (EXCLUDING DIAGONAL WIND BRACING, WHICH 15 TREATED AS A 'STRUCTURAL MEMBER' UNDER 2006 AMENDMENT DEFINITIONS. D. MAXIMUM ENCLOSURE HEIGHT SHALL NOT EXCEED 20-FEET E. ALLOWABLE DEFLECTION OF 'L / 60% AS SPECIFIED IN TABLE 016I0,1, FOR NON -HIGH VELOCITY HURRICANE ZONES. F. CONTINUOUS LOAD PATH 15 PROVIDED, 2. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD): A. ALL EXTRUSIONS SHALL BE ALUMINUM ALLOY %06346 (NOTE THAT THE SPLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALLOY %06146, IF THIS MATERIAL IS MORE READILY AVAILABLE TO THE CONTRACTOR) (SEE COMPONENT SHAPES AND SIZES AT RIGHT). B. FASTENERS 5HAL1- BE ALUMINUM ALLOYS 2024-T4 E 1015-T6, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL, OR 300-SERIES STAINLESS STEEL. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE APPROPRIATE MEANS FOR SEPARATION OF DISSIMILAR MATERIALS AS THEY ARE DEFINED IN SECTION 02003.8A. THE CONTRACTOR MAY IMPLEMENT ANY OF THE MEANS SPECIFIED IN THIS SECTION. ANY ALTERNATIVE MEANS MUST BE ACCOMPANIED BY A LETTER OF CERTIFICATION FROM THE PRODUCT'S MANUFACTURER (THIS LETTER MUST BE SIGNED AND SEALED BY A FLORIDA LICENSED STRUCTURAL ENGINEER), WHICH STATES THAT THEIR PRODUCT MEETS / EXCEEDS ALL OF THE REQUIREMENTS SPECIFIED IN THE ABOVE - LISTED SECTION. THIS LETTER SHALL ALSO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD FROM BD.Q., INC. C. SCREEN CLOTH SHALL BE VINYL COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 x 14 (58% OPEN). 3. ALL FASTENERS THAT PASS THROUGH ANY EXTRUSION INTO CONCRETE, MASONRY, WOOD, STEEL, ALUMINUM OR ANOTHER EXTRUSION SHALL HAVE A 5/8-INCH DIAMETER WASHER, MINIMUM (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD), AND SHALL BE NO MORE THAN 18-INCHES CENTER - TO - CENTER SPACING. 4. ALL FASTENERS ADJACENT TO UPRIGHTS THAT DO NOT REQUIRE REINFORCING ANGLE CLIPS, SHALL BE PLACED WITHIN TWO (2) INCHES OF THAT UPRIGHT (TYP. FOR BOTH SIDES). 5. SCREEN DOORS) MAY BE LOCATED IN ANY SCREEN WALL PANEL, EXCEPT FOR THOSE THAT CONTAIN DIAGONAL WIND BRACING CK-BRACING'). ALL DOORS SHALL BE SELF -CLOSING AND SELF -LATCHING. DOORS INSTALLED IN AN ENCLOSURE THAT SURROUNDS A POOL / SPA SHALL HAVE DOOR LATCHES INSTALLED FIVE (5) FEET ABOVE THE FLOOR, MINIMUM. 6. COPIES OF THIS ENGINEERING SPECIFICATION / DESIGN DETAIL ARE TO ONLY BE CONSIDERED VALID FOR PERMITTING OR DESIGN CERTIFICATION FURP05EB WHEN ALL SHEETS OF ANY SUBMITTED SET BEARS THE ENGINEER'S ORIGINAL SIGNATURE (IN BLUE INK), UNDER HIS EMBOSSED SEAL. R.D.Q., INC. SHALL NOT BE RESPONSIBLE FOR NON -ORIGINAL COPIES THAT ARE SUBMITTED, THAT HAVE ANY UNAUTHORIZED CHANGES, ALTERATIONS OR DELETIONS ON THEM. 1. THESE ENGINEERING DETAIL DRAWINGS ARE ONLY VALID IF THE DATE ACCOMPANYING THE ENGINEER'S ORIGINAL SIGNATURE IS LESS THAN 90 DAYS OLD. NO BUILDING OFFICIAL OR BUILDING DEPARTMENT SHOULD ACCEPT COPIES THAT ARE OLDER THAN THIS, AND SHOULD REQUEST THE SUBMITTING CONTRACTOR OBTAIN UPDATED / CURRENT ENGINEERING. 8. ALL ENGINEERING SPECIFICATIONS AND DETAIL DRAWING CONTAINED WITHIN THIS ENGINEERING DOCUMENT ARE THE 60LE PROPERTY OF B.D.Q., INC. ANY UNAUTHORIZED COPYING OR OTHER REPRODUCTION IN PART OR WHOLE OF THESE DOCUMENTS WILL NOT BE PERMITTED AND WILL BE PROSECUTED TO THE FULLEST EXTENT ALLOWED BY LAW. S. THERE SHALL BE NO REDISTRIBUTION OF THESE ENGINEERING DOCUMENTS BY THE PERSON OR COMPANY THAT ORIGINALLY PURCHASED SIGNED AND SEALED COPIES FROM B.D.Q., INC., WITHOUT EXPRESS WRITTEN AUTHORIZATION FROM B.D.Q., INC., AND THE ENGINEER OF RECORD. WALL COLUMN SCHEDULE (ALLOW. COLUMN HEIGHTS VS. MALL PANEL WIDTH) L/60 MAX. ALLOWABLE DEFLECTION (140 MPH, EXR "C", 29 P.S.P. DESIGN LOAD) DIMENSION COLUMN HEIGHT vs WALL PANEL WIDTH (DESIGN PRESSURE = 21 PSF) SIZE Tf Tw 6' 0" 7' 6" 7' 0" ' 6" 6' 0" 8 6' 1 5' 0" 4' 6" V 0' 4 L .100 .046 6' 4' 6'1' 6' V 1' 4' 1' 8' Vol a' 6' IT0. 2x5 L A 16 .050 1' 8' 8' (D' 813, 8' 1' 8' I I' lb, 3' 9113, 10' 3' 10, 11, 2X6 L .120 .050 Vol` 8' 3' 8' 6' 8' 9' V? 9' 6' 10' 1' 10' 1' II' 3' 2X7 L .120 .057 V 8' V 0' 9' 3' 9' 8' 10' 1' 10' 6' II' 0' 11,11 1213, 2X8 L .224 .072 101' II' 0' 11' 4° 11' 8' 12' 3' 129 135' 142' 150 ' 2x9 L (L) .209 .072 12' 10' 13' 3" 13' 8' 14' 3' 14' 9' 15' 5' 16' 2' 11' 1' 18' 2' 2x9 L (H) .306 .082 15' 9' 16' 4' IT O' Ill 7 18' 3' 19' 2' 20' 1' 21' 1' 22' 4' 2X10 L .389 .092 18' 9' IV 4' 20' 1' 20' 9' 21' 8' 22' 1' 23' 6' 24' 11' 26' 4' TF Tw It- GC1 IFCNENT 5HAFE 5 AND 5FEC IF I CAT I ON5 �tLl , SELF -MATING CV) w .044 .040 3'1 2' Ix3O.B. Ix20.8. 2 x 3 "H" 3 x 3 'N' THE ACTUAL VALUES FOR 'Tf' (FLANGE THICKNESS) AND 'Tw' (WEB THICKNESS) FOR THE VARIOUS SIZE SELF -MATING MATERIAL ARE INDICATED ON THE UPRIGHT HEIGHT AND BEAM SPAN TABLES. i r-er ^ 1- I-ti 1-1- u"" 1 w a H05T STRUCTURE WITH STRUCTURAL GUTTER MANSARD ROOF REAM SPAN Lu LuMANSARD BEAM 5PAN5 ARE BASED ON A MAXIMUM SPLICE ANGLE OF 30- FOR HALF -MANSARD BEAM SPANS, USE VALUE5 SHOWN IN 'MANSARD BEAM SPAN TABLE (5AME MAX. SPLICE ANGLE UJI (30') APPLIES TO HALF -MANSARD BEAMS) Q N HOST STRUCTURE WITH STRUCTURAL GUTTER PEAK / GABLE ROOF BEAM SPAN .093 1 2' ! x 2 x .0133 TUBE DIAG. BRACING BEAM SPANS AND COLUMN SIZES ON THIS SHEET ARE RASED ON SIMULTANEOUS LOADING, AS DEFINED IN TABLE 02002.4, F.B.C. 2004, FOR 140 MPH WINDS, FOR EXPOSURE CATEGORY 'C' (29 P.S.F. WALLS, 8 P.5F, ROOF, FOR NON-HVHZ) FLAT SIMPLE ROOF BEAM SCHEDULE FoRFLAT BEAMs, Lm mAx.o4omPH,sm. 'n SIZE DIMENSION ROOF PANEL WIDTH vs BEAM SPAN (FOR MAX. WALL HEIGHT OF 16' 01 Tf 1 Tw 8' 0'. T 6' 7' 0' 6' 6" V 0" 5' 6' V 0' 4' 6" 4' 0' 2x4 L .100 ,045 12' 0' IT 5' 12-10- IT 3' 13' 11' 14' 6' 15' 2' 16' 0- Il' 0- 2x5 L .118 .050 Will 15' 1' 15' 1' IV 2' 16' T Jill, 1815, 19' 4' 205' 2x6 L .120 ,060 15' 2' 15' l' 1w 2' IV 9' IT 5' 18' 2' 19' 1' 20' 1' 21' 3' W L .120 .067 Ie' 6' IT O' 11'1' 18' 3' IV O' I9' 9' 208' 21' 9' 23' 0' 2x8 L VA .072 20' 0' 20' 8' 21' 4' 22' 2' 23' 0' 24' 0' 25' 1' 2(9' 4' 21' 11' 2X9 L (L) '209 .072 24' 2' 25' 0' 25' 9' 26' 13'2l' 9' 29' 0' 3m' 3' 2x9 L (H) .306 .01V 29' 9' 30- 9' 31-10-1 32' II' 1 34' 3' 35' 1' 31' 3' 2x10 L .389 .092 35, 0' 36' 2' 1 31' 4' 1 36' 8' 40' 2° 1 41' 9' 1 43' 8' 0) REPRESENTS SPAN VALUES THAT ARE DEFLECTION -LIMITED BEAM SPAN CALCULATION NOTE: THE SPANS IN THESE TABLES ARE BASED ON BOTH THE HOST STRUCTURE MOUNTING POINT AND WALL HEIGHT BEING THE SAME MEASUREMENT MANSARD I CENTER PEAK (GABLE) ROOF BEAM SCHEDULE um mAx (iao mPH, EV.'M *THIS - SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL RISE OF 3' 0" (36")* DIMENSION ROOF PANEL WIDTH vs BEAM SPAN (FOR MAX WALL HEIGHT OF 6' 0') SIZE Tf Tw 8' 0' 7' 6' T 0' V W 0 0' V 6' S' 0' 4' 6' N 0" 24 L .116 .050 2x6 L .120 .050 2X1 L .120 .057 W L .224 .072 6' 9' 10' 4' 12' 0' 13' 0' 1V 2' 16- 10, 18' 10' 20' 11' 2x91. (L) .209 .072 I5' v I6' 3' 11, w 19' 0' 20' S' 22, m' 23, 9' 25' 9' 28' 0' 2x9 L (H) .306 .082 23' 0' 24' 3' 25' 1' 21' 0' 26 6' 30' 3' 32' 3' 34' 6' 36' II' 2X10 L .092 29' 8' 1 30' II' 1 32' 3' 1 33' 9' 1 35' 6' 1 31' 5' 39' 6' 1 41' II" 44' 8' MANSARD / CENTER PEAK (GABLE) ROOF BEAMSCHEDULE La f. a (vw mpH, EV. Tj *THIS SPAN TABLE IS LIMITED MA MAXIM VERTICAL. RISE OF 3' 0" (361* DIMENSION ROOF PANEL WIDTH vs WAM SPAN (FOR MAX. WALL HEIGHT OF 12' (n SIZE Tf Tw 8'0" 7'6" i0' 66' S'0° 680 60' 4'6" N0" 2x5 L .116 .050 24 L .120 .050 2x7 L .120 .057 224 .072 1011, (L) .209 .072 13' 4' WE,' f236- 15' 6' I1' 1' 15' 9' 22' 2' 24' 8' L (H) .306 .082 18' 13'20' 3' 21' 8' 25' 4' 21' 3' 29' 5' 31-13- 34' 6' 2x10 L .389 .092 1 26' 5' I..21l 10' 1 29' 5Y 33' 1' 1 35' I° 31' 3° 1 3V 9' 42' 8' MANSARD / CENTER PEAK (GABLE) ROOF BEAM SCHEDULE Leo eaAx. (14o MPH, W. T1 THIS SPAN TABLE IS LIMITED TO A MAXIMUM VERTICAL RISE OF 3' 0" (36")* DIMENSION ROOF PANEL WIDTH vs BEAM SPAN (FOR MAX. WALL HEIGHT OF 16' (n SIZE Tf Tw V O' 7' 6' 7' 0' 6161 VolSol 60, 4' 6' 4' 0" 2x7 L .120 .057 2x8 L .224 .072 10, 0' 2x9 L (L .209 .072 8' 0' II' 6' 14' 9' ITT 21' 0' 2x9 L (H) .308 .082 13' 3' 15' 3' 11' 4' 19' 5' 21' 6' 23' 9' 26' 4' 29' 0' 32' 0' 2x10 L Am .092 1 22' 9' 24' 6' 26' 4' 28' 3' 30' 2' 32' 5' 34' II' 31' 6' 408' MANSARD BEAM SPANS OF LESS THAN 8' 0' ARE OMITTED FROM THIS TABLE I= LLww_ CL uj In z H0 ;E o zicawc .m4�1.m� ®� O U! ® 0 J Lu ,ma t!J u- ® < p 0 U45ujw� R W ~ OW co co Lu m R- ac 8 F � C) � Lu onJju Lu �. c LLI CL %bwo Lu { 9 UP TO 16' REAM SPAN 16' TO 24' BEAM SPAN 24' TO 32' BEAM SPAN 32' TO 40' BEAM SPAN O-INDICATES WALL PANEL THAT SHALL HAVE DIAGONAL "K"-BRACING IN IT UP TO 8' WALL HCHT EXIST. HOST STRUCTURE , :FAJ F] MENNEN m rpl... h 1 0 EX15T. HOST STRUCTURE EXIST. HOST STRUCTURE NUMBER OF PANELS r VARIES 8' TO 12' WALL HGHT ■ PAN INS FAA m EL EL EXIST. H05T STRUCTURE TOTAL NO. OF BAYS VARIES THREE (3) RAYS ON EACH END OF OUTER -MOST WALL SHALL HAVE DIAL. BRACING EXIST. HOST STRUCTURE TOTAL NO. OF BAYS VARIES THREE (3) BAYS ON EACH END OF OUTER -MOST PANELS AND TWO (2) PANELS IN SECOND OUTER -MOST ROW OF PANELS SHALL HAVE THE DIAGONAL BRACING (AS SHOWN) THE BRACING SCHEMATICS SHOWN ABOVE ARE THE SAME BRACING CONFIGURATION, REGxARDLESB OF ROOF TYPE (MANSARD, PEAK, DOME, FLAT, ETC.) DESIGN NOTES: ALL DIAGONAL BRACING, USED EITHER IN THE ROOF OR AS 'K'-BRACING IN THE WALLS SHALL BE 2' x 2' x .093 WALL THICKNESS TUBE, AND SHALL BE CUT TO FIT SNUG, WITH NO PLAY OR SHIFT IN THE BRACING. SEE DETAILS AT RIGHT FOR CONNECTION SPECIFICATIONS DESIGN NOTE: ALL THRU-BOLTS PASSING THROUGH ANY ALUMINUM MATL. WITH A WALL THICKNESS LESS THAN .090, SHALL HAVE A 11/a-INCH (OUTSIDE DIA.) FENDER WASHER (SEE GENERAL NOTE "2 ON SHEET 02 REGARDING SEPARATION OF DISSIMILAR METALS). THE CONTRACTORS MAY, IF THEY CHOOSE, INSTALL THE ANGLE CLIPS FOR THE DIAGONAL. TUBE BRACING (WHERE IT ATTACHES TO THE SELF - MATING SCREEN ROOF BEAMS) WITH TAE THRU-BOLTS ONLY PASSING THROUGH ONE HALF OF THE BEAM. THIS 15 A STRUCTURALLY ADEQUATE ALTERNATIVE, AND WILL PERMIT INSTALLATION OF THESE ANGLE CLIPS IN THEIR SHOP, DURING FABRICATION (POSSIBLY SAVING TIME DURING INSTALLATION IN THE FIELD). UPPER ANGLE CLIP TO RE PLACED AT SAME ANGLE AS THE MANSARD LEG OF THE SCREEN ROOF BEAM 2 x 3 x ,010 EVE RAIL 2 x 2 x HIV ANGLE CLIP, CUT AT A 45' l+/-) ANGLE AND ATTACHED TO THE 2 x 3 x .010 EVE RAIL WITH ONE (1) 1/4' DIA. THRU-BOLT, WITH FENDER WASHER (SEE DE51GN NOTE ABOVE 2 x 3 x 210 SCREEN ROOF PURLIN ON NOTE: ALL DIACONAL BRACING SHALL BE ATTACHED VIA THE 2 x 2 x '/a" ANGLE CLIPS, AS SHOWN, AND SHALL HAVE EACH END ATTACHED TO EITHER THE SCREEN ROOF BEAM OR TO THE EVE RAIL. NO DIACONAL. BRACING SHALL BE ATTACHED TO ANY OF THE ROOF PURLINS 2 x 3 x .010 SCREEN ROOF PURLIN ( 2 x SMSCREEN ROOF BEAM TYP) SPLICE JOINT 2 x 2 x 11/8' ANGLE CLIP, CUT AT A 45° e W-) ANGLE AND ATTACHED TO THE SCREEN — — ROOF BEAM WITH ONE (1) 114' DIA. THRU-BOLT, WITH ® FENDER WASHER (SEE DESIGN NOTE ABOVE 2 x 2 x .093 DIAGONAL ROOF BRACE, CUT AT 45' ANGLE (+/-) AT EACH END AND ATTACHED TO EACH ANGLE CLIP WITH A I%' DIA. THRU-BOLT, AS SHOWN TYPICAL ANGLE ARTICULATION TO CREATE UPWARD ANGLE D 146ONAL ROOF 5RAGN6 DFA I L x w p o10 o� w Uzi w U. o col W o z�®� Lu co w w n o L Ce_ In Z g C.J LLI a-cl) Iu 0 r-L 0 0=-Lu. �ugz d�LL�� a- 6W .4Tw +I� z o u n a SEAM 5PLIGE 5PECIFIGATION5 1114 TEK SCREW (TYPICAL) w �v w T11SAME AS 'A' BELOI _ JUST REVERSED x6 e ® 0� co 0 ® 0 1 0 0 0 0 0 = 1 0 o o �1 1 0 0 0 o 0 0 w 3x3x.010H 0 9® = CORNER UPRIGHT 1 0 0 F 0 _ 0 10 S T'l-A a SPLICE PLATE MATERIAL SHALL BE 1/4' THICK (MIN.) AND BE EITHER 06063-T6 OR %061-T6 ALLOY SEAM SPLICE DETAIL (2 x S 5EAM5 AND LARGER) (MUST USE 1/4" THIC< GU55ET PLATE)* 014 TEK SCREW (TYPICAL) _ DIA ONAL WALL BRAGIN CK" 5RAGIN ) I)ETAL -i 0 �w 0 0 0 0 0T 4-INCH x 4-INCH x ® ` Q .010 PLATE, WITH 0 ® 0 0 C (4)112 TEKS IN THE 0 3 x 3,(3) 012 TEK5 1 o IN THE BOTTOM I 1 0 SPLICE PLATE MATERIAL x 2 AND (3) 012 TEK p�Ase 0\D1N SHALL BE 3/I6" THICK (MIN.) IN THE 2 x 2 BRACI 12�osa� AND BE EITHER 06063-T6 OR %061-T6 ALLOY ISEAM SPLICE DETAIL (2 x I BEAMS AND SMALLER) *(MUST USE 3/I6" THICK GUSSET PLATE)$ vzo TYP. ROOF w SPLICE PLATE TOLERANCE NOTE: BEAM to Lu_ Lu ALL SPLICE PLATES (ALUMINUM ALLOY'6063-T6 or %06146) SHALL BE CUT TO BE +0.000 / IC TYPICAL AL 3/16' -0.0625, AS INDICATED IN THE THICK SCHEMATIC DRAWING AT LEFT SPLICE PLATE . 3X3 oHa..+r it COLUMN 2x2xOS3T DIAGONAL RF I x 2 BOTTOM SCREEN-FRA' 2 x 3 x .010 ROOT 7�PUR0N —Ix2013TOP SCREEN FRAME 2 x 2 x .093 TUBE DIAGONAL BRACE 3 x 3 X.010 CHAIR RAIL 2 x 2 x .OS3 TUBE - DIAGONAL BRACE DETAIL "A" (OUTSIDE) (INSIDE) I x 2 OB BOTTOM SCREENFRAME ' 3 'H° CORNER )LUMN 2 x 2 x .OS3 TUBE DIAGONAL BRACE I x 2 BOTTOM SCREEN FRAME [-INCH x 3-INCH x OS3 ANGLE, CUT 4- INCHES LONG, WITH (3) 012 TEK5 IN THE 3x3,(3)012TEKS IN THE BOTTOM I x 2 AND (3) 012 TEK5- IN THE 2 x 2 BRACE 2 x 5MB SCREEN ROOF BEAM 2 x 5M5 UPF e�n 2 x 2 x .093 TUBE - DIAGONAL BRACE 3x3x.010—""' CHAIR RAIL 2x2x.093TUBE- DIAGONAL BRACE 2 x 5 SMB UPRIGHT (MINIMUM SIZE) 2 x 2 x .093 TUBE - DIAGONAL BRACE 2 x 5 5M5 UPRIGHT (MINIMUM SIZE) 3x3x.010 CHAIR RAIL 2x2x033TUBE - DIAGONAL BRACE DETAIL I`E31' 0 0 0 10 0 0 0 0 0 00 0 0 0 0 0 0 (OUTSIDE) 0 0 0 0 0 0 (INSIDE) u. Lu Q� ®r�� cJ3 In 0 —'Lu >� �I1"°�o �LL Wp z > I m to— 51 4-INCH x 10-INCH x .010 PLATE, WITH (1) pit C) Z � W H 2 Lu W TEKS IN THE SMB UPRIGHT, (3) 012 TEK5 pW- W�oCa zZ iE a i 8 IN THE CHAIR RAIL AND (3) p12 TEKS IN EACH 2 x 2 BRACE ' N -3x3x.010 6li->' CHAIR RAIL 0 LLJ Z Z ® Lu W e uj cn w _ 0 H CL I -INCH x 3-INCH x .093 ANGLE, CUT 4- INCHES LONG, WITH (3) N2' TEK6 IN THE SMB UPRIGHT AND (3) *12 TEK5 IN THE 2 x 2 BRACE tu',�°� —3x3x.010 CHAIR RAIL I -INCH x 3-INCH x . .093 ANGLE, CUT 4- INCHE5 LONG, WITH (3) 012 TEKS IN THE R.: n z� Z � 5M5 UPRIGHT AND (3) 012 TEKS IN THE ¢ � -iE H g < 2 x 2 BRACE cy ti le d F 6� 5G E EN ROOF ENCLOSURE -TO -HOST 5TfRUGTURE ATTACHMENT [DETAIL DE51GN NOTE: THE 3-INCH LEG OF THE ANGLE SHALL BE PLACED AGAINST THE I x 2. THIS ALLOWS A MIN. EDGE P16TANCE FOR THE FASTENERS (FROM THE EDGE OF THE ANGLE) OF ONE -INCH, AND MAINTAINS A SIX-INCH MIN. CENTER -TO -CENTER DISTANCE FOR THE MAX. SIZED CONCRETE ANCHORS (3/8' x 31/29 CAP (TYP) HOST C.B.S. WALL (TYP) TYP SCREEN ROOF REAM I x 2 2' x 3' x .125' ANGLE W/ (4) 012 TEK5, TYP. EACH 51DE OF BEAM FrA5GIA REINFORCEMENT pE51GN NOTE: ALL FASCIA BOARDS ON ANY EXISTING HOST STRUCTURE THAT WILL HAVE ANY PART OF THE PROPOSED SCREEN ENCLOSURE ATTACHED TO-ITSHALL BE REINFORCED, BY PLACING ONE lU 1/4' x 4' LAG SCREW INTO THE END OF EVERY TRUSS TAIL (WHERE THE PROPOSED SCREEN ENCLOSURE IS BEING INSTALLED). THESE TRUSS TAILS MUST BE PILOT DRILLED WITH A 5/32" DRILL BIT TO PREVENT SPLITTING THE END OF THE TRU55 TAILS. IT SHALL BE THE REP5ON5I5ILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THIS STEP IS COMPLETED, AS SPECIFIED, PRIOR TO ANY INSTALLATION TAKING PLACE.. FASTENER SHALL BE 1/4' x 3 1/2' RED -HEAD ITW TAPCON FOR ALL 2' x (o' BEAMS AND SMALLER. FASTENERS SHALL BE 3/8' DIA. FOR 2' x 1' BEAMS AND LARGER (SEE DESIGN NOTE ABOVE REGARDING 3/6 FASTENER SPACING) WALL ,ATTACHMENT 10-INCH LONG 025 THICK) EXTRUDED- °Z' GUTTER INSERT, TYP CENTERED ON EACH ROOF BEAM, WITH FOUR (4) 010 TEKS THRU TOP LIP OF GUTTER 1/4' x 21/4' LAGS, FOUR (4) - IN EACH 10-INCH INSERT AND AT 24' O.C. (MAX. SPACING) IN THE REST OF THE GUTTER (PILOT DRILL FASCIA W/ 5/32" BIT TO AVOID SPLITTING) 5' STRUCTURAL GUTTER (CONT.) FA5GI,A REINFORCEMENT 5PEGIFIC ATION5 1/4' x 4' LAG SCREW, TO BE INSTALLED INTO THE END OF EVERY TRUSS TAIL WHERE A SCREEN ENCLOSURE WILL BE ATTACHED. THE TRUSS TAIL SHALL BE PILOT - DRILLED WITH A 5/32' DRILL BIT (TO PREVENT SPLITTING THE END OF THE TRUSS TAIL) SEE 'SNAP / LAP CONNECTION' NOTE ON SHEET I FOR 5PEC.'5 I x 2 SCREEN FRAME (TYP) PLAN VIED 2 x 3 x .125 ANGLE CLIP (CUT 2' LONG) W/ 3-INCH LEG AGAINST I x 2. CLIP SHALL HAVE FOUR (4) *12 TEK5 INTO SIDE OF ROOF BEAM AND TWO (2) 014 x 2' TEKS (PER ANGLE CLIP) THRU GUTTER AND INTO 'Z' GUTTER INSERT (TYP. ONE ANGLE CLIP ON EACH SIDE OF EACH BEAM) TYP. 2 x SCREEN ROOF BEAM (MAY BE FLAT OR SLOPED) TRUSS TAIL (TYP) CAP (TYP) 2 x FASCIA 30ARD (TYP) NOTE: FASCIA ATTACHMENT REQUIRES A 2 x FASCIA BOARD (MINIMUM). A 'I x' FASCIA 15 ONLY ADEQUATE: FOR THIS INSTALLATION WHEN THERE 18 A 2 x 5115- FASCIA BEHIND IT. IN THIS CASE, THE LAGS MUST PENETRATE THE SU15-FA5CIA 11/2' (MIN. EMBEDMENT). IT SHALL BE THE RESPONSIBILITY OF THE SCREEN CONTRACTOR TO VERIFY THE PRESENCE OF THIS 5UB-FA6CIA. 10-INCH LONG (.125 THICK) EXTRUDED - 'Z' GUTTER INSERT, TYP CENTERED ON EACH ROOF BEAM, WITH FOUR (4) 010 TEKS THRU TOP LIP OF GUTTER 2 x HOUSE FASCIA (SEE FASCIA NOTE ABOVE) 1/4' x 2 �/4' LAGS, FOUR (4) — — IN EACH 10-INCH INSERT AND 24" O.G. (MAX. / SPACING) IN THE REST OF THE GUTTER (PILOT DRILL FASCIA W/ 5/32' BIT TO AVOID SPLITTING) I x 2 x .093 ANGLE SPACER - (FOR ANGLED FASCIA BD. ATTACHMENT), ATTACHED W/ TWO (2)-ROWS OF 010 TEKS (STAGGERED), EACH ROW AT 18' O.C. (MAX. SPACING) F UGTURAL GUTTER CONNECTION [DETAIL TYP SCREEN ROOF BEAM I x 2 2' x 2' x .125' ANGLE W/ (4) "12 TEK5, TYP. EACH 51DE OF BEAM 1/4' x 2 1/2' LAG SCREW TYP. I EACH SIDE OF BEAM (2' x b' BEAM5 AND SMALLER) 3/8' x 2 1/2' LAG SCREW (2` x l' BEAMS AND LARGER) FASCIA ATTACHMENT SEE 'SNAP / LAP CONNECTION' NOTE ON SHEET I FOR SPEC.'S 0 _o 0 0 o 0 U-CHANNEL CAP (TYP) I x 2 SCREEN FRAME (TYP) 5' STRUCTURAL GUTTER (CONT.) 5EGTION VIEW TYP. 2 x SCREEN ROOF BEAM (MAY BE FLAT OR SLOPED) 2 x 3 x .125 ANGLE CLIP (CUT 2')-,ONG) W/ 3-INCH LEG- 1Ae3AIN6T I x 2. CLIP SH L HAVE FOUR (4) #12 T 5 INTO SIDE OF ROOF EAM AND TWO (2) $14 x 2' TEKS (PER ANGLE CLIP) THRU GUTTER AND INTO 7' GUTTER INSERT (TYP. ONE ANGLE CLIP ON EACH SIDE OF EACH BEAM) r- �, Lu 0 a cc w ��� �E9 Lou w z w u_ _1 0 ;oEl �22CL �Y � w Lu IR ca 8�®W� ;E a�IZ8 Y x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE (U 3/8' RED -HEAD ''RU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) C; SIDE WALL w 1 Lu I x 2 OB BOTTOM FRAME 2w z 1 x 3 OB SIDE -WALL CORNER 0 UPRIGHT N PLAN VIEW 2x3x.010EVE RAIL, TYP. (CONTINUOUS) I x 2 OB TOP FRAME I x 3 OB SIDE -WALL CORNER UPRIGHT 010 x 2' SM5 SCREW, WITH 5/6' DIA. WASHER (SEE GENERAL NOTE 113, SHEET 02) TO BE 18- INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 2 x 3/16' ANGLE, WITH FOUR (4) 012 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) I x 2 OB BOTTOM FRAME ELEVATION VIEW FRONT WALL I x 2 06 BOTTOM FRAME 2 3i4', MIN. EDGE DISTANCE 3 x •010 FRONT WALL ZNER UPRIGHT 010 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE 03, SHEET 02) TO BE IS - INCHES, CENTER -TO -CENTER MAX. SPACING MANSARD SCREEN ROOF BEAM(BEYOND) 2 x 5 x 14' ANGLE (2-INCHE6 LONG) WITH (2) #14 TEKS INTO TOP OF 2 x 3 EVE RAIL AND (2) 014 TEK5 INTO THE FRONT OF THE 3 x 3 H FRONT WALL CORNER UPRIGHT 3 x 3 x 210 FRONT WALL CORNER UPZDGE T 2 3i4', MIN. DISTA CE 0 0 z �o- CORNER UPRIGHT [DETAIL NOTE: THIS ATTACHMENT I x 2 O.B. SCREEN FRAME, DETAIL ALSO APPLIES TO TYP. BETWEEN UPRIGHTS A 2 x 2 SCREEN FRAME, OR AS UPRIGHTS AGAINST W/ THE FASTENER BEING A WALL OR COLUMN 4' IN LENGTH, TO 1/4' DIA, x 31/4' TAPC,ON MAINTAIN A 2' MIN. TO 13E PLACED AT NO MORE EMBED. THAN IS' O.G. (RE: GEN. NOTE p3) MIN. EMBEDMENT FOR CONC. / C.B.S. / MASONRY ALL TAPCONS SHALL SURFACE . BE 2' INTO CONCRETE. NOTE: ALL FASTENERS SPECIFIED IN 'COLUM-TO-FOUNDATION' DETAILS PERTAIN ONLY TO THE FASTENERS TO BE PLACED ON EITHER SIDE OF COLUMNS. THIS DETAIL 15 FOR ALL INTERMEDIATE FASTENERS FOR I x 2 SCREEN FRAME TO EITHER CONC. DECK OR C.B.S. MASONRY WALL. 2 x 3 x .010 ROOF PURLIN 2 x 3 x D10 EVE RAIL, TYP. (CONTINUOUS) 2 x 5 x 118' ANGLE (2-INCHES LONG) WITH (2) 014 TEK5 INTO TOP OF 2 x 3 EVE RAIL AND (2) 014 TEKS INTO THE FRONT OF THE 2 x SMB SIDE WALL UPRIGHT I x 2 OB TOP FRAME 010 x 2' SMS SCREW, WITH 5/0' DIA. WASHER (SEE GENERAL NOTE 03, SHEET 02) TO BE IS - INCHES, CENTER -TO -CENTER MAX. SPACINGS 2 x 5 SM5 UPRIGHT (MINIMUM 51ZE FOR ANY UPRIGHT ON A SCREEN ROOF ENCLOSURE) 4' MIN. EDGE D15TANCE SEE 'MINIMUM FOOTER TABLES' ON SHEET pl 0 0 0 21i8' x 1'i2' U-CHANNEL CLIP ATTACHED TO THE EVE RAIL WITH SIX (6) #12 TEKS, AND (3) p12 TEKS INTO EACH SIDE OF THE 2 x 3 ROOF PURLIN (TO RE ATTACHED ON THE TOP END TO THE SCREEN ROOF BEAM IN THE SAME MANNER 2 x 4 x 1i8' ANGLE (2-INCHES LONGS) WITH (2) #14 TEKS INTO BOTTOM OF THE 2 x 3 PURLIN AND (2)114 TEKS INTO THE BACK OF THE 2 x SM5 SIDE WALL UPRIGHT 3 x 3 x .010 CHAIR RAIL (TYP) 2 x 2 x 3/16' ANGLE, WITH FOUR (4) #12 TEK5 INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) I x 2 OB BOTTOM FRAME SIDE WALL UPRIGHT DETAIL BEAM SIZE 2x5-2x6 2x7-2x8 2x9 2 x 10 2 x SMB SCREEN ROOF BEAM 2 x 3 x .010 ROOF PURLIN 2 x 5 x'/8' ANGLE (2-INCHE5 LONG) WITH (2) 014 TEKS INTO TOP OF 2 x SM5 REAM AND (2) #14 TEK5 INTO THE FRONT OF THE 2 x SM5 FRONT WALL UPRIGHT I x 2 OB TOP FRAME 110 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE p3, SHEET 02) TO BE 18- INCHES, CENTER -TO -CENTER MAX. SPACING 2 x 5 SMB UPRIGHT (MINIMUM SIZE FOR ANY UPRIGHT ON A SCREEN(ROOF ENCLOSURE) 23/4' MIN. EDGE DISTANCE I x 2 OB BOTTOM FRAME SEE 'MINIMUM FOOTER TABLES' ON SHEET 01 NO. OF 014 TEKS (PER SIDE) (2) 114 TEKS (4) 114 TEKS (5) 014 TEKS (6) #14 TEKS 33/4' 3' MIN. MIN. SCREEN ROOF BEAM SHALL OVERLAP ON THE OUTER SIDE OF BOTH SIDES OT THE UPRIGHT (TYP. EACH BEAM -TO -UPRIGHT CONNECTION) SEE TABLE ABOVE FOR NUMBER OF 014 TEKS, A5 SPECIFIED BASED ON BEAM SIZE 3 x 3 x .010 CHAIR RAIL (TYP) 2 x 2 x 3/16' ANGLE, WITH FOUR (4) p12 TEKS INTO THE UPRIGHT AND ONE (1)3/0' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) FRONT WALL UP IOHT DETAIL �n� �orC� LU Z LLJ ®�.. 0 W co LdJ w 0 0 CL CARRIER BEAM APPLICATIONS FOR SOLID ROOF / SCREEN ROOF COMBINATION JOBS (EASED ON 8' 0" COLUMN SPACING) GENERAL NOTES: TRIBUTARY AREA CONTRIBUTING SCREEN ROOF LOAD WIDTH (TRIBUTARY AREA) (SEE SCHEMATIC LAYOUT FOR DESCRIPTION) FOR SOLID ROOF 5'0' v0' T0' W0' w0° W0' 1110' 120' 13,0' IN 0. 15'0' W0° 1T0' iv0' 1910° N0' 4'0' '2x5(A) '2x5(6) '2x5(5) '2x5(5) '2x5(6) '2x6(115) '2x6(5) '2x1(5) '2x1(5) '2x1(C) 12x1(C) '2x8(C) 12x8(C) '2x8(C) 12x8(C) 2x8(D) 50 '2x5(5) '2x5(6) '2x(I(B) '2x6(B) 12x1(E) '2x1(5) 2x1(5) 2x1(C) 1112x8(C) '2x8(C) '2x8(C) '2x8(C) 2x8(C) 2x8(D) 2x8(D) 2x8(D) 60" '2x6(6) '2x1(5) '2x103) '2x1(B) '2xl(C) '2x8(C) '2x81G1 '2x81C) '2x8(C) 2x8(G) 2x6(W 2x6(0) 2x8(q) 2x8(p) 2x8(D) 2x8(p) TO' '2x1(5) '2x1(B) '2x8(C) '2x8(C) '2x8(C) '2x8(C) '2x8(C) 2x8(C) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) V0' '2x8(C) 2x1(C) 2x8(C) 2x8(C) 2x8(C) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x8(D) 2x9-L(0) 2x9-L(D) 2x9-L(p) 9' V ' 2 x 8 (C) 2 x 6 (C) p 2 x 8 (C) 2 x 8 (0) 2 x 8 (P) 2 x 6 (0) 2 x 8 (D) 2 x 8 (p) 2 x 6 (0) 2 x 8 (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (p) 2 x 9-L (p) 2 x 9-1- (D) 10' 0' 2 x 8 (C) 2 x 8 (D) 2 x 8 (D) 2 x 8 (D) 2 x 8 (D) 2 x 8 (D) 2 x 8 (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (0) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (E) 2 x 9-L (E) CARRIER BEAM APPLICATIONS FOR SOLID ROOF / SCREEN ROOF COMBINATION JOSS (BASED ON 10' ®p COLUMN SPACING) TRIBUTARY AREA CONTRIBUTING SCREEN ROOF LOAD VADTH (TRIBUTARY AREA) (SEE SCHEMATIC LAYOUT FOR DESCRIPTION) FOR SOLID ROOF 50' 8'0' TV &0" 90' 10'0' 11,0' 120' 13,00 IN0' 15,IV 18'0' 1T0' IN 0' 190' 290- N0' '2x1(6) '2x8(6) '2x8(5) '2x8(B) '2x8(5) '2x8(C) 02x8(C) '2x8(C) '2x8(C) 2x8(D) 2x9-L(D) 2x9-L(D) 2x9-L(1)) 2x9-L(D) 2x9-L(D) 2x9-L(D) 5'0' ' 2 x 8 (B) ' 2 x 8 (B) ' 2 x 8 (C) ' 2 x 8 (C) ' 2 x 8 (C) ' 2 x 8 X) 2 x 8 (C) 2 x 9-L (ID) 2 x 9-L (D) 2 x 9-L (p) 2 x 9-L (0) 2 x 9-L (D) 2 x 9-L (P) 2 x 9-L M) 2 x 9-1- (D) 2 x 9-L (D) 2 x 8 (C) 2 x 8 (C) 2 x 8 (C) ' 2 x 8 (C) 2 x 9-L (P) 2 x 9-L (0) 2 x 9-L lD) 2 x 9-L (P) 2 x 9-L (P) 2 x 9-L (p) 2 x 9-L (P) 2 x 9-L (D) 2 x 9-L (P) 2 x 9-L (0) 2 x 9-H (p) 2 x 9-H (D) T V ' 2 x 8 (C) ' 2 x 9-L (C 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (0) 2 x 9-L (D) 1 x 9-L (D) 2 x 9-L (D) 2 x 9-L (q) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-14 (D) 2 x 9-H (D) v 09 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L M) 2 x 9-11- (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-H (D) 2 x 'I (D) 2 x 9-14 (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 9' 0' 2 x 9-L (0) 2 x 9-1- (p) 2 x 9-1- (D) 2 x 9-L (D) 2 x 9-L M) 2 x 9-H (D) 2 x 9-14 (D) 2 x 9-H (p) 2 x 9-4 (ID) 2 x 11 (0) 2 x 11 (0) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (F) 2 x 9-H (F) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-H (D) 2 x 9-H (0)l 2 x 9-H M) 2 x 9-14 (E) 2 x 9-H (E) 2 x 9-H (E) 2 x II (E) -2 x 9-H (E) 2 x 9-14 (E) 2 x 9-H (E) 2 x 9-H (F) 2 x 9-H (F) 2 x 9 H lF) 2 x 9-H (F) TRIBUTARYAREA CONTRIBUTING SCREEN ROOF LOAD WIDTH (TRIBUTARY AREA) (SEE SC 4R%TIC LAYOUT FOR DESCRIPTION) FOR SOLID ROOF S 0' Vol TV 8' (' 9' 0' 10' 0' 11,00 1201, 13' 0' IN 0" 15' 0' 1 *0' IT 0' IW 0' 19 0° 20' 0' N 0' ' 2 x 8 (B) • 2 x 8 (C) ' 2 x 9-L (C 2 x 9-L (C P 2 x 9-L (C 2 x 9-L (D) 2 x 97L (D) 2 x 9-L (D) 2 x 9-L (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (P) 2 x 9-H (D) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-L (G ' 2 x 9-L lG 1 2 x 9-L (G) 2 x 9-L (P) 2 x 9-L (pJ 2 x 9-L (D) 2 x 9-H (D) 2 x.9-H (p) 2 x 9-14 (D) 2 x 9-H.lp) 2 x 9-H (ID) 2 x 9-H (D) 2 x 9-14 (E) 2 x 9-H (E) 2 x II (E) 2 x 9-H (E) 6102 ' 2 x 9-L (C 2 x 9-L (D) 2 x 9-L (D) 2 x 9-H (D) 2 x 9-14 (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-4 (D) 2 x 9-H (E) 2 x 9-H (E) 2 x 9 H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (F) T 0' 2 x II (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (D) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9=14 (E) 2 x 9-H (E) 2 x 9-H (F) 2 x 9-H (F) 2 x 9-4 (F) 2 x IC (F) v 0' 2 x 9-H (P) 2 x 9-H (D) 2 0-H (D) 2 x 9-H (D) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (F) 2 x 9-H (F) 2 x 10 (F) 2 x 10 (F) 2 x 10 (F) 2 x 10 (F) 9' 0' 2 x III (D) 2 x 9-14 (E) 2 x 9-14 (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (E) 2 x 9-14 M) 2 x 10 (F) 2 x 10 (F) 2 x 10 (F) 2 x 10 (F) 2 x 10 (F) 2 x 10 (Fl 2 x 10 (F) 10' 0° 2 x 9-14 (E) 2 x 9-H (E) 2 x 9-H (E1 2 x 9-H (E) 2 x 9-H (E) 2 x 9-H (F) 2 x 9-14 (F) 2 x 10 (F) 2 x 10 (Fl 2 x 10 (F) 2 x IC (F) 2 x 10 (F) 2 x 10 (F) 2 x 10 (F) 2 x 10 (F) 2 x 10 (F) TABLE NOTES: I. THIS SET OF DETAIL SHEETS MUST BE ACCOMPANIED BY FULL SEALED SETS OF BOTH 'POOL / PATIO ENCLOSURE WITH SCREEN ROOF' AND 'ALUMINUM ROOF (PAN OR INSULATED) SCREEN ROOM ENCLOSURE' ENGINEERING DETAIL SHEETS TO BE VALID FOR PERMITTING PURPOSES. 2, IF PROPOSED JOB'S COLUMN SPACING EXCEEDS THE SPACING INDICATED ON ONE OF THE TABLES (AT LEFT) THE NEXT LARGER SPACING SPECIFICATIONS SHALL GOVERN WITH REGARDS TO THE CARRIER BEAM AND TOOTER SIZES. 3. IF JOB CONDITIONS EXCEED THE LARGEST COLUMN SPACING: INDICATED ON THE TABLES AT LEFT (12' 0' CENTER - TO -CENTER), THE COLUMN SPACING MUST BE REVISED TO FALL WITHIN THESE PARAMETERS, OR THE JOB MUST BE REDIRECTED BACK TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC DESIGN 4. ANY CONDITIONS THAT EXCEED ANY OF THE DESIGN PARAMETERS INDICATED ON THIS DESIGN DETAIL SHEET, THE JOB MUST BE REDIRECTED BACK TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC DESIGN. 5. REFER TO GENERAL NOTES AND ALL OTHER DESIGN NOTES ON BOTH THE SCREEN ROOF AND ALUMINUM ROOF ENGINEERING DETAIL SHEETS, AS THEY ALL SHALL STILL GOVERN ANY AND ALL FABRICATION AND INSTALLATION OF THESE ENCLOSURES. 6. THE TRIBUTARY AREAS INDICATED ON THESE TABLES (AT LEFT) ARE DEFINED HALF OF THE SPAN OF THE SCREEN ROOF BEAMS AND THE ALUMINUM ROOF PANELS. IF SPANS ON A SINGLE JOB VARY, THE CARRIER BEAM / FOOTER PAD MUST BE 1. ALL BEAMS INDICATED WITHIN THESE TABLES ARE SELF -MATING BEAMS. (NO TUBULAR SHAPES SHALL BE USED). USED THAT IS BASED ON THE WORST- 2. THE LETTERS IN PARENTHESIS CORRESPOND TO LETTER SYMBOLS SHOWN IN THE 'FOOTER PAD KEY' TABLE, ON SHEET 03 OF THE "ALUMINUM ROOF SCREEN CASE SCENARIO FOR BOTH CONDITIONS, ROOM ENCLOSURE' ENGINEERING SHEET (WHICH ORIGINAL SEALED COPIES MUST ACCOMPANY THIS ENGINEERING DETAIL -SHEET), AND REPRESENT THE AND THAT APPLICATION SHALL BE USED REQUIRED FOOTER PAD SIZES NEEDED TO RESIST THE IMPOSED UPLIFT LOADS GENERATED BY EACH DIMENSIONAL REPRESENTATION. THROUGHOUT THE ENTIRE JOB. 3. THE APPLICATIONS THAT ARE MARKED WITH AN ASTERISK (1), ARE 'GOLUMN 6GENAR105 THAT MAY BE MOUNTED DIRECTLY ON EXISTING FOUR -INCH THICK CONCRETE DECK, UTILIZING 'ANCHOR DETAIL 11 (AS SHOWN ON SHEET 06 OF THE 'ALUMINUM ROOF SCREEN ENCLOSURE" ENGINEERING SHEET. ALL OF THE FOLLOWING CONDITIONS MUST BE MET FOR THIS APPLICATION TO BE STRUCTURALLY ADEQUATE. IF ANY OF THE CONDITIONS ARE NOT OR CAN'T BE MET, THEN THE CONTRACTOR MUST INSTALL THE SPECIFIED FOOTER PAD, AS INDICATED WITHIN THE TABLES ABOVE: A. THERE MUST BE AT LEAST THREE AND A HALF (3' 6') OF CONTINUOUS, UNBROKEN CONCRETE IN ALL FOUR DIRECTIONS FROM THE BASE OF THE PROPOSED COLUMN BASE LOCATION (49 SQUARE FEET). B. THIS CONCRETE MUST BE FREE FROM ANY CRACKS, STRESS -RELIEF CUTS, DECO -DRAINS, ETC. WITHIN THIS 49 SQUARE FOOT AREA. C. THERE MUST BE EVIDENCE VIA PREVIOUS OR CURRENT PERMIT AND INSPECTION RECORDS INDICATING THAT THIS CONCRETE WAS POURED WITH EITHER 6" x 6', J0110 W.W. MESH OR "FIBERMESH' REINFORCEMENT. THIS IS THE ONLY WAY THIS CAN BE VIERIFIED TO THE LEVEL OF CERTAINTY REQUIRED FOR THE ENGINEER OF RECORD TO CERTIFY THAT THIS INSTALLATION 15 STRUCTURALLY ADEQUATE TO RESIST THE IMPOSED LOADS, NOTE: THIS DESIGN ENGINEERING SHEET IS SPECIFIED FOR EXP. CAT. 'C' (NON-HVHZ), BUT SHALL ALSO_ BE UTILIZED FOR ANY INSTALLATIONS IN AN EXP. CAT. 'B' BUILDING AREA. 4. IF ANY JOB SITE CONDITIONS EXCEED ANY DESIGN PARAMETERS ON THIS DETAIL SHEET, THE JOB SHALL BE DIRECTED BACK TO THE ENGINEER OF RECORD FOR SITE -SPECIFIC DESIGN. w000 lz w z o �ent" Lu Q iKCU0z IXoo� Si3 � 0 Lz uj 6>X8w to to 0ct�WW� a i�LuF ®mc_aa �eD LU a) o C) a, cr0wz I C) J 0 Lu ��c�mU -9 U0®o u- ®�? O O®��U ��.6- f f- PLATE SPECIFIED ON THE. i ROOF ENGINEERING SHEET )LUMN WITH OFFSET NOTCH' SHALL BE CUT TO FIT UP TO TOM OCR THE STRUCTURAL 4ND WILL ONLY HAVE ONE BOLT OF THE BOLTS THAT CIFIED FOR EACH GIVEN lON PASSING THROUGH TE. THIS PLATE SHALL STILL HAVE FOUR (4) 014 TEKS INTO THE SUPPORT COLUMN (AS ORIGINALLY SPECIFIED ON THE ALUMINUM ROOF ENGINEERING SHEET DETAIL) THREE-50LT CONNECTION THE 3/16' PLATE SPECIFIED ON THE ALUMINUM ROOF ENGINEERING SHEET (FOR 'COLUMN WITH OFFSET NOTCH' DETAIL) SHALL BE CUT TO FIT UP TO THE BOTTOM OG THE STRUCTURAL GUTTER, AND WILL ONLY HAVE ONE (I) THRU BOLT OF THE BOLTS THAT ARE SPECIFIED FOR EACH GIVEN CONNECTION PASSING THROUGH THE PLATE. THI5 PLATE SHALL STILL HAVE FOUR (4) #14 TEKS INTO THE SUPPORT COLUMN (AS ORIGINALLY SPECIFIED ON THE ALUMINUM ROOF ENGINEERING SHEET DETAIL) TWO e 50L T CONNECTION ALUMINUM ROOF (EITHER 3-INCH RISER PANS OR INSULATED ROOF SYSTEMS) FOR ALUMINUM ROOF -TO -CARRIER - BEAM CONNECTION, CONTRACTOR MUST ONLY USE THE 2 x 2 ANGLE WITH THRU-BOLT CONNECTION (SEE ALUMINUM ROOF ENGINEERING SHEET FOR COMPLETE SPECIFICATIONS). THE ONLY EXCEPTION WILL BE THAT THE 2 x 2 ANGLE WILL NOT BE CONT., AS IT WILL BE INSTALLED IN CONT, 5ECTION6 BETWEEN THE SUPPORT COLUMNS 3 x 3 OR 4 x 4 SUPPORT COLUMN - (BEYOND) SEE ALUMINUM ROOF ENGINEERING SHEET FOR COLUMN - TO -CARRIER BEAM CONNECTION SPECIFICATIONS 2 x CARRIER BEAM, 51ZED FROM CARRIER BEAM TABLES ON SHT. I OF THESE ENGINEERING DETAIL SHEETS SEE ALUMINUM ROOF ENGINEERING - SHEET FOR -SPECIFICATIONS ON THE CARRIER BEAM STITCH SCREWS 5' STRUCTURAL GUTTER (CONT.) ATTACHED - TO CARRIER BEAM WITH 94 TEKS AT 0' O.C. MAX. SPACING (IN ADDITION TO THRU BOLTS AT EACH 'Z' GUTTER INSERT) EACH 10-INCH LONG 'Z' GUTTER INSERT SHALL HAVE THREE (3) 1/4' DIA THRU BOLTS, THAT SHALL PASS THROUGH THE CARRIER BEAM AND THE 2 x 2 ANGLE ON THE BACK SIDE (NOTE THAT SUPPORT COLUMNS SHALL NOT BE LOCATED AT THE SAME POINT ON THE CARRIER BEAM AS THE SCREEN ROOF BEAM51, AS THE 2 x 2 ANGLE ON THE BACK OF THE CARRIER BEAM MUST ALSO BACK THE 'Z' GUTTER INSERTS) BE 0#0 lLl SEE POOL / PATIO SCREEN ROOF ENGINEERING SHEET FOR COMPLETE SPECIFICATIONS FOR SCREEN ROOF BEAM -TO -STRUCTURAL GUTTER CONNECTION UTILIZING 10-INCH LONG 'Z' GUTTER INSERT SCREEN ROOF BEAM, AS SIZED FROM SCREEN ROOF ENGINEERING SHEET (FLAT OR PITCHED) rOR THIS CONNECTION, THE CONTRACTOR SHALL ADD A 2 x 2 x .125 ANGLE, BENEATH THE I X 2 SCREEN FRAME WITH FOUR (4) 012 TEKS INTO THE SIDE OF THE SCREEN ROOF BEAM AND ONE lU 3/8' DIA. THRU BOLT, PLACED THROUGH A 3/4' ALUM. PICKET FERRULE (INSIDE THE GUTTER) AND THI5 THRU BOLT SHALL HAVE A FENDER WASHER ON THE BACK 51DE WITH THE NUT, TYR ONE ANGLE AND THRU BOLT ON EACH SIDE OF EACH SCREEN ROOF BEAM. ,ALUMINUM ROOF TO 6CREEN ROOF CONNECTION [DETAIL DESIGN NOTE: WITH REGARDS TO THE COLUMN -TO -CARRIER BEAM CONNECTION (AS INDICATED ON THE 'FOOTER PAD KEY' TABLE ON THE ALUMINUM ROOF ENGINEERING SHEET), WHERE THE SPECIFIED CONNECTION IS MADE WITH TWO (2) THRU-BOLTS, ONE BOLT SHALL BE PLACED THROUGH THE RACK SIDE OF THE GUTTER. WHERE THE SPECIFIED CONNECTION 15 MADE WITH THREE (3) THRU-[BOLTS, TWO OF THE THREE BOLTS SHALL BE PLACED THROUGH THE BACK 81DE OF THE GUTTER (SEE DETAILS AT LEFT). A a g d Lei C u. w�� cq 3 H 9 9Sc uot Q v ��� �? m o in C.9 �W iE 8 Lu LL 0o� CLU6� O cowV ®gLu_90hi a 8 U- O O OLU®-cm � o :z y AO O CL •a: Z;,ca o�®oa ®L46 a!W Ec 6ENM4L NOTES AND DE51GN FARAMETER5: I. T1415 OVERALL DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTER 16 AND CHAPTER 20, 2006 AMENDMENTS TO FLA. BLDG. CODE 2004, AND 15 BASED ON THE FOLLOWING PARAMETERS: A. WIND SPEED: 140 M.P.H., 3-SECOND GUST B. EXP06URE CATEGORY: 'C' C. DE51GN LOADS: LIVE LOAD m 30 P.SF., UPLIFT LOAD 9 24 P.5F., SCREEN WALL DESIGN LOAD 9 29 P.5F. D. MAXIMUM HEIGHT: 30' 0' FOR'EXPOSURF CATEGORY 'B' AND W 0' FOR EXPOSURE CATEGORY 'C'. E. ALLOWABLE DEFLECTION: 'L' / 120 (AS SPECIFIED IN TABLE "1610.1, FOR NON -HIGH VELOCITY HURRICANE ZONES) F. CONTINUOUS LOAD PATH 15 PROVIDED 2. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD) A. ALL EXTRUSIONS: ALUMINUM ALLOY %063-T6 (NOTE: 5PLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALUMINUM ALLOY 0606146, IF THI5 ALLOY 15 MORE READILY AVAILABLE TO THE CONTRACTOR). B. FASTENERS: ALUMINUM ALLOYS *2024-T4 4 01015-T6, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL, OR 300-SERIE5 STAINLESS STEEL. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE FOR SEPARATION OF D1651MILAR MATERIALS AS THEY ARE DEFINED IN SECTION 02003.8.4. HE / SHE MAY IMPLEMENT ANY OF THE MEANS LISTED IN THESE SECTIONS. ANY ALTERNATE MEANS MUST BE REVIEWED AND APPROVED IN WRITING, BY THE ENGINEER OF RECORD, PRIOR TO ANY INSTALLATIONS UTILIZING THE SUBJECT METHOD. C. ROOF PANELS: SEE ROOF PANELS SPECIFICATION ON THE ROOF PANEL SPAN TABLE. D. SCREEN CLOTH: SHALL BE VINYL -COATED WOVEN FIBERGLASS, MAX. DENSITY 18 x 14 MESH (58% OPEN, MINIMUM). 3. ALL FASTENERS THAT PA55 THROUGH ANY EXTRUSION INTO CONCRETE, MASONRY, WOOD, OR OTHER ALUMINUM EXTRUDED FRAME MEMBER, MUST HAVE A 5/5-INCH DIAMETER WASHER (MINIMUM), AND BE NO MORE THAN 24 INCHES CENTER -TO -CENTER SPACING (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD). 4. ALL FASTENERS ADJACENT TO COLUMNS THAT DO NOT REQUIRE REINFORCING ANGLE CLIPS, MUST BE PLACED WITHIN 4 INCHES OF THE UPRIGHT (ON BOTH SIDES). (REFER TO GENERAL NOTE *3 FOR SPACING SPECIFICATIONS) 5. ANY CARPORT OR SCREEN ROOM THAT HAS ANY SITE -SPECIFIC DESIGN ELEMENTS THAT DO NOT COMPLETELY CORRESPOND WITH, OR IN ANY WAY EXCEED THE DESIGN SPECIFICATIONS INDICATED ON THI5 DESIGN DOCUMENT SHALL BE RE -DIRECTED BACK TO THE ENGINEER OF RECORD FOR CERTIFICATION OR FURTHER SITE -SPECIFIC DESIGN. 6. ALL WELDED CONNECTIONS SHALL BE WELDED WITH AN INERT -GAS -SHIELDED ARC OR RESISTANCE WELDING PROCESS (AS PER SECTION 020032.13, F.B.C. 2004). ALL WELDING OF STRUCTURAL ALUMINUM MEMBERS SHALL BE PERFORMED BY A CERTIFIED WELDER (AS PER SECTION 02003.8.1.4, F.B.G. 2004). 1. COPIES OF THIS ENGINEERING DESIGN DETAIL SPECIFICATION DRAWING (ALL SHEETS) ARE ONLY TO BE VALID. FOR PERMITTING PURP06ES OR FOR DESIGN CERTIFICATION PURPOSES WHEN ALL SHEETS OF ANY SUBMITTED SET BEAR THE ENGINEER'S ORIGINAL SIGNATURE (IN BLUE INK) UNDER HIS EMBOSSED 5EAL. NO 5ET6 OF THESE FASCIA ATTACHMENT NOTE: I. FOR ATTACHMENT OF ANY SOLID ROOF STRUCTURE TO THE FASCIA OF THE EXISTING H05T STRUCTURE, THE FASCIA BOARD MUST BE A NOMINAL 2' THICK BOARD (INSTALLATION ON A I x FASCIA BOARD 15 POSSIBLE IF THERE IS A 2 X SUB -FASCIA, WHICH MUST BE VERIFIED . PRIOR TO ANY INSTALLATION BY THE CONTRACTOR). 2- THE 'FASCIA-TO"TRUSS TAIL' CONNECTION MUST BE REINFORCED. BY THE PLACEMENT OF ONE (1) 1/4' x 4' LAGS SCREW THROUGH THE FASCIA AND INTO EACH TRUS5 TAIL (FOR THE ENTIRE LENGTH OF FASCIA THAT SHALL HOST A PROP05ED SOLID ROOF STRUCTURE. THESE LAGS SCREW HOLES MUST BE PILOT -DRILLED WITH A 5/32' DRILL BIT (TO PREVENT SPLITTING OF THE TRUSS TAIL). THE CONTRACTOR SHALL BE RE- SPONSIBLE FOR LOCATING THE TRU55 TAILS ON THE JOB SITE. IF REQUESTED, THE CONTRACTOR MUST BE AISLE TO PROVIDE ANY NECESSARY EVIDENCE NEEDED TO VERIFY ACTUAL PENETRATION OF THESE LAGS INTO THE TRUSS TAILS IF REQUESTED TO D 50 BY EITHER THE ENGINEER OF RECORD OR ANY BUILDING OFFICIAL. 3. THE EXISTING H06T STRUCTURE'S OVERHANG SHALL INOT EXCEED 2' 0' (24 INCHES). IF THE OVERHANG DOES EXCEED THIS DIMENSION, ALTERNATIVE SUPPORT AND ATTACHMENT SPECIFICATIONS MAY NEED TO BE DESIGNED BY THE ENGINEER OF RECORD. HOST STRUCTURE (WALL / FASCIA) SPECIFICATION DRAWINGS SHOULD BE ACCEPTED, OR CONSIDERED VALID IF THE PATE UNDER THE EMBOSSED i1 �SIDE SCREEN i SEAL 15 MORE THAN 90 PAYS OLD. ;� WALLS BELOW). 8. ANY ORIGINAL SIGNED (IN BLUE INK) AND SEALED 51TE-6PECIFIC DESIGN DRAWINGS, ALONG WITH ITS SITE- SPECIFIC SPECIFICATIONS, SHALL ONLY SUPERSEDE THESE DESIGN SPECIFICATION [DRAWINGS, WHEN IT 15 ' SPECIFICALLY STATED ON THE SITE DRAWING AND THAT SITE DRAWING 15 DEFINED AS A 'SITE -SPECIFIC' Q I ROOF LOAD REARING DESIGN. u I WALL (BELOW) S. SCREEN POOR(S) MAY BE PLACED INTO ANY 8CREEN WALL PANEL, AS PER OWNER'S SELECTION. EACH DOOR MUST BE SELF -CLOSING AND SELF -LATCHING. CONCRETE ANCHOR 5PECIFICATIONS: ALL CONCRETE ANCHORS SPECIFIED ON THI5 DETAIL SHEET ARE MANUFACTURED BY 'RED HEAD' ANCHORING SYSTEMS, AS ALL LOAD CAPABILITIES ARE BASED ON TEST DATA FURNISHED BY RED HEAD IN THEIR PRODUCT AND RESOURCE BOOK. NO SUBSTITUTIONS OF ANY OTHER MANUFACTURER'S CONCRETE ANCHORS IS PERMITTED WITHOUT SUBMITTAL OF THE COMPANY'S TEST DATA (TO VERIFY EQUIVALENT LOAD CAPACITIES) AND A WRITTEN, " SIGNED AND SEALED LETTER OF AUTHORIZATION FROM THE ENGINEER OF RECORD. ANY UNAUTHORIZED ANCHOR SUBSTITUTION SHALL BE DEEMED NON -COMPLIANT WITH THIS DESIGN. THE ANCHORS TO BE USED FOR APPLICATIONS SPECIFIED IN THIS ENGINEERING DESIGN PLAN ARE AS FOLLOWS: 1/4' DIA FASTENERS: RED HEAD ITW TAPCON, WHICH SHALL HAVE A MINIMUM EMBEDMENT INTO CONCRETE OR C.B.S. WALL OF 13/4'. 1/2', 5/8' 4 3/4' DIA. FASTENERS: ALL FASTENERS OF THESE DIAMETERS SHALL BE 'RED- , HEAD TRU50LT WEDGE' ANCHORS. SEE 'FOOTER PAD KEY' TABLE FOR INDIVIDUAL FASTENER EMBEDMENTS AND MINIMUM EDGE AND CENTER -TO -CENTER DIMENSIONS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER) W ` e xa UPRIGHT BEAM GANTILEvER 5PACING 25% OF ALLOWABLE COLUMN SPACING (MAXIMUM) 5TANDARD 5CREEN ROOM SCHEMATIC HOST STRUCTURE (WALL / FASCIA) O = N SUPPORT COLUMN INTERMEDIATE ( INTERIOR) CARRIER BEAM t I COLUMN I SPACING SCREEN WALLS--�_ (BELOW) I it IEEE SGHc'PFk4IG ABOVE) COLUMN SPACING zQ (MAXIMUM) a Q U STANDARD SCREEN ROOM WITH .INTERMEDIATE CARRIER BEAM ALLOWABLE ROOF PANEL SPANS THE SPANS INDICATED IN THE TABLES BELOW ARE BASED ON A LIVE LOAD OF 30 P.S.F., AND THE APPLICABLE WIND LOAD, AS DEFINED IN TABLE #2002.4, CHAPTER 20, FLA. BLDG. CODE 2004. ALLOWABLE DEFLECTION SHALL BE L / 120, AS SPECIFIED IN TABLE #1610.1, CHAPTER 16, FLA. BLDG. CODE 2004 (FOR NON -HIGH VELOCITY HURRICANE ZONES). MAXIMUM HEIGHTS SHALL BE 30 FEET OR LESS FOR EXPOSURE'B" AND 15 FEET OR LESS FOR EXPOSURE "C'. 3-INCH RISER PANS PANS SHALL BE ROLL -FORMED, IN ACCORDANCE WITH INDUSTRY STANDARDS, AND SHALL BE MADE FROM ALUMINUM ALLOY 03105- H14 OR ALLOY#3105-H28 (2 RIB MINIMUM). ROOF PANEL OVERHANG PANEL THICKNESS .024 .032 .040 2° 17 AXIMUM 10181 12' 0' 1218, 3", 4" AND 6° INSULATED PANELS THE INSULATED PANEL SPANS INDICATED IN THE TABLE BELOW ARE THOSE THAT ARE SPECIFIED BY ELITE PANEL PRODUCTS (FLA. STATE PRODUCT APPROVAL #FL-7561, DWG. NO. FL-1 pot AS PRODUCED BY DO KIM a ASSOCIATES, LLC, CONSULTING ENGINEERS) IF A CONTRACTOR CHOOSES TO USE ANOTHER MANUFACTURER'S PANELS, THEY SHALL STILL BE LIMITED BY THESE SPANS, AS THESE SPANS ARE THE BASIS FOR ALL OF THE DETAILS INDICATED WITHIN THIS ENGINEERING SHEET. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING THE OTHER MANUFACTURER'S PRODUCT APPROVALS. ALLOWABLE SPANS WITH 1 LB DENSITY CORE MATERIAL OVERHANG INSULATED ELAICKNESS / SKIN THICKNESS. 3" / .024 3" / .032 ' 1.024 4' / .032 6° / .024 7-1.032 2' 0' MAXIMUM 10' 9' 14' 0' 12' 6' 11' 4' 15' 1' 21' 6' ALLOWABLE SPANS WITH 2 LB DENSITY CORE MATERIAL OVERHANG 3' 1.024 3° / .030 4' / .024 4" / .030 6' / .024 6- / .030 2' 0' MAXIMUM 1 16' 3' 1 IT 6' IV 6- 22' (o' 22' 4' 22' Y "CLEAR SPANH SCHEMATIC DIAGRAM 'CLEAR SPAN' 'OVERHANG' x� g BEAM AND COLUMNS O.W.) ROOF SCREW SPACING AND EDGE DISTANCE SPEC.'S THIS TABLE IS BASED ON THE PROPERTIES OF C-1022 LOW CARBON STEEL SM5 AND SELF -DRILLING (TEK) SCREWS, WHICH ARE AN INDUSTRY STANDARD SCREW. SCREW SIZE NOMINAL SCREW DIAMETER (IN.) MIN. EDGE DISTANCE MIN. CENTER -TO - CENTER DISTANCE *8 0.156 5/16' 1/16' 010 0.188 3/8, 1/2' *12 1 0.219 I/2'1 5/8' *14 1 0.250 1 5/8' 1 3/4' FOR BRICK PAVER INSTALLATION: FOR INSTALLATION ON A BRICK PAVER DECK, PLEASE NOTE ALL COLUMNS MUST BE MOUNTED DIRECTLY TO THE CONCRETE FOOTER PADS (THE PRICK PAVERS CAN BE CUT TO FIT UP TO AND AROUND EACH COLUMN). THIS DESIGN DOF5 NOT PERMIT INSTALLATION OF THE SUPPORTING COLUMNS ON TOP OF THE PAVERS, AS THE DESIGN LOADS WILL NOT ADEQUATELY BE RF515TED. > Co M_ 0 8 RE LL 0 CL p e C9a w :,� � C� Lu OO � a < �M� a: 0, ul NI ALLOWABLE FRONT WALL UPRIGHT SPACING. 645ED ON ROOF SPAN MAXIMUM UPRIGHT SPACING FOR ROOF LOAD BEARING (FRONT) SCREEN WALL (CNTR TO-CNTR) ROOF CLEAR 2 x 3 x .090 CARP. BM. 2 x 5 x .125 CARP. BM. SPAN VW O.H. 2' Of O.H. 1' 0" O.H. 2' 0" O.H. r 0" r 1" B'r 8' 0' 910" 618" 6'3" 8'0'(`) 8'0"(°) 10' 0" 6' 6" S' 1" 8' 0' (') 8' 0' (') 11, 0" V 4" 610, 8' 0" (°j 8' 0" 12' 0" 6' 2" 5' 10" 8' 0" (`) 8' 0" (`) 14'0" 5111" 5'8" 8'0"(°) 8'0"(°) 1610" 518" SIBS 8'Ir 8'0'(°) 17' 0" 5' r 5' 4" 8' 0' (`) 8' 0" (°) 1&0" 51W 5'3" 8'0"(') r11" MAXIMUM UPRIGHT HEIGHTS BASED ON UPRIGHT 5PACING WALL COLUMN SCHEDULE (ALLOW. COLUMN HEIGHTS VS. WALL PANEL WIDTH) U60 MAX.. ALLOWABLE DEFLECTION (140 MPH, EXP.'C', 29 P.S.F. DESIGN LOAD) DIMENSION COLUMN HEIGHT vs WALL PANEL WIDTH (DESIGN PRESSURE = 21 PS9 SIZE Tf Tw► 8' 0° r 6' r 0' 6' 6' 6' 0' 5' 6" v 0° 4' 6" 4' 0' 20 L .100 .045 6' 4' 6' 1' 6' Y 1' 0' 1' 4' 1' 8' 8' 0' 8' 6' 9' 0' 2x5 L .116 .050 1' 8' V 0' 8' 3' 8' 1' 8' II' 9' 3' 9' 9' 10' 3' ID' 11' 2x6 L .120 .050 8' 0' 8' 3' 8' 6' VS' 9' 2' 9' 6' 10' 1' 10' 1' 2x7 L 1 .120 .057 8' 8' 9' O' 9' 3' 9' 8' 10' 1' 10' 6' II' 0' 11' 1' 12' 3' 2X8 L 224 .072 10' 1' II' 0' II' 4' II' 8' 12' 3' 12' 9' IV 5' 14' 2' 15, 0' 24 L (L) .2W .072 12' 10' 13' 3' 13' 8' 14' 3' 14' 9' 15' 5' 16' 2' 11' 1' 18' 2' 2x9 L (H) .306 .082 15' 9' 16' 4' IT O' IT 1' 18' 3' 15'2' 20' I' 21' 1' 22' 4' 2x10 L .389 .092 18' 9' IV 4' 20' 1' 20' 9' 21' 8' 22' 1' 23' THE UPRIGHTS SPECIFIED IN THIS TABLE ARE DESIGNED FOR PLACEMENT UNDER A SOLID ALUMINUM ROOF STRUCTURE, AND ARE BASED ON A DESIGN LIVE LOAD (ROOF) OF 30 P.S.F. (DESIGN BASED ON A WORST -CASE OF A CLEAR SPAN OF 19' 0') THE UPRIGHTS SPECIFIED IN THIS TABLE ARE DESIGNED FOR USE WITH SCREEN CLOTH WITH MAXIMUM DENSITY OF 18 x 14 MESH (68% OPEN, MINIMUM). (') NO SCREEN WALL PANEL SHALL EXCEED 8' 0" CENTER -TO -CENTER BOTH CARRIER BEAMS SPECIFIED ON THE UPRIGHT SPACING TABLE ABOVE ARE TO BE TUBE -TYPE CARRIER BEAMS (NOT S.M.B.) IF A PROPOSED ALUMINUM ROOF EXCEEDS 19 0" CLEAR SPAN, IT MUST BE DESIGNED SITE -SPECIFICALLY BY THE ENGINEER OF RECORD FOR THIS DESIGN DOCUMENT MINIMUM FOOTER TA51-E5 FOR I/ERIMETER SCREEN WALLS /flONO MAX. ROOF FOOTER SPAN 8' x 6' WITH (U 150 CONT. UP TO 14' 8' x 12' WITH (1) °50 CONT. 14' TO Il' Ip' x 12' WITH Il' TO 20' (1) 050 CONT. ISOLATED MAX. ROOF FOOTER(') SPAN 12' x 14' WITH (2) 050 CONT. Up TO 14' 14' x 16' WITH 14' TO Il' (2) S5 CONT. 16' x 1(a' WITH 11' TO 20' (2) 050 CONT. IF A JOB EXCEEDS THESE PARAMETERS, THE FOUNDATION MUST BE SITE -SPECIFICALLY DESIGNED BY THE ENGINEER MONOLITHIC FTG. LOAD CAPACITIES ARE BASED ON A MIN. OF 3 FEET OF CONT. CONCRETE, 2,500 PSI MINIMUM, W/ WIRE OR FIBERMESH REINFORCEMENT ()ISOLATED FOOTERS MAY BE USED ON EDGE OF EXIST. CONC. SLAB OR UNDERNEATH THE PERIMETER OF BRICK PAVER DECK (ALL SIDES) COMPONENT SHAPES AND SPECIFICATIONS 3e 2e 2' 3' I x 3 1 x 2 O.R. 2x3'H' 3x3'H' 5EL_F-MATING (°)..') THE ACTUAL VALUES FOR 'TF' (FLANGE THICKNESS) AND 'Tw' (WEB THICKNESS) FOR THE VARIOUS SIZE SELF -MATING MATERIAL ARE INDICATED ON THE UPRIGHT HEIGHT AND CARRIER BEAM TABLES. ALL "TUBE° TYPE BEAMS OR COLUMNS SPECIFIED IN THI5 ENGINEERING DE51GN DOCUMENT SHALL HAVE THE SAME WALL THICKNE55 ON ALL FOUR SIDE5 (TYP). OVER CLEAR SPAN CLEAR SPAN OVER HANG HANG HOST STRUCTURE (WALL / FASCIA) MAX I I ROOF LORD BEARING� II MAX WALLS(BtLOW) �- II_ I_-.. GABLE-� i 5IDE SCREEN RIDGE I WALLS (BELOW) i I BEAM I I I --z -1 1/2 OF 1 lie OF R CLEAR CLEAR o SPAN SPAN z RIDGE BEAM T AREARY N GABLE PLAN VIEW NOTE: ,. a COLUMNS THAT SUPPORT CARRIER BEAMS (INCLUDING s= RIDGE BEAMS FOR GABLE ROOFS) AND ARE WITHIN A W a SCREENED WALL PANEL SHALL BE SELECTED FROM THE nWALL COLUMN SCHEDULE" ON THIS SHEET. SEE DETAIL BELOW —,,, NOTE: MAXIMUM PITCH FOR GABLE ROOF SHALL BE 3: 12 12 31 MAX. COLUMN SPACING GABLE ELEVATION GAE3LE ALUMINUM ROOF SCHEMATIC DIAGRAM 4' ALUMINUM ROOF PANEL (TYP.) 3/' III{°III{' 3V GABLE RIDGE BEAM AS SIZED FROM CARRIER BEAM TABLE 2 x 2 x .125 ANGLE (2' LONG) W/ 6 6FOUR (4) %2 TEK5 INTO COLUMN �Y AND FOUR (4) 112 TEK5 INTO THE O O �p `r BOTTOM OF CARRIER BEAM, TYP. 0 O _ ONE ANGLE ON BOTH THE INSIDE 0 O 0 _ AND OUTSIDE OF THE COLUMN o 2 x 2 TOP RAIL (TYP. FOR TOP 0 0 O 4' x 8° x 3/16' THICK PLATE WITH OF SCREEN WALL PANEL THAT ®0 0 NINE (9) 114 TEK5 INTO SIDE OF IS UNDER ALUMINUM ROOT PANEL CARRIER BEAM AND NINE (9)1114 TEKS INTO SIDE OF UPRIGHT, TYP. I x 2 SCREEN FRAME (ON EITHER ONE PLATE ON EACH SIDE OF THE SIDE OF THE CARRIER BEAM BEAM -TO -UPRIGHT CONNECTION SUPPORT COLUMN) (TEKS TO BE SPACED AS SHOWN) OUTER SCREEN WALL SCREEN WALL SUPPORT COLUMN SURFACE SIDE VIEW FOR GABLE RIDGE BEAM (ALSO APPLICABLE TO OTHER INTER- MEDIATE CARRIER BEAM SUPPORTS) SEE 'TYP. GABLE ROOF ALUMINUM ROOF PANEL (TYP.) DETAIL' FOR SPEC.'S GABLE RIDGE BEAM AS SIZED a FROM CARRIER BEAM TABLE 2 x 2 TOP RAIL (TYP. FOR Top 4' x 8' x 3/16' THICK PLATE WITH OF SCREEN WALL PANEL THAT NINE (9) °14 TEKS INTO SIDE OF 15 UNDER ALUMINUM ROOF PANEL CARRIER BEAM AND NINE (9) 014 TEKS INTO SIDE OF UPRIGHT, TYP. I x 2 SCREEN FRAME (ON EITHER o o ONE PLATE ON EACH SIDE OF THE 5I0E OF THE CARRIER BEAM BEAM -TO -UPRIGHT CONNECTION SUPPORT COLUMN) (TEKS TO BE SPACED AS SHOW) SCREEN WALL SUPPORT COLUMN 2 x 2 x .125 ANGLE (2' LONG) W/ FOR GABLE RIDGE BEAM (ALSO FOUR (4) 12 TEK5 INTO COLUMN APPLICABLE TO OTHER INTER- AND FOUR (4) 0112 TEKS INTO THE MEDIATE CARRIER BEAM SUPPORTS) BOTTOM OF CARRIER BEAM, TYP. FRONT VIEW ONE ANGLE ON BOTH THE INSIDE AND OUTSIDE Or THE COLUMN GA15LE RIDGE SEAM TO SCREEN WALL 51JPPQRT COL. � w 2w,i� o oz a�CD(ujCD �en�iscao� wig o� � 0 -4 c�'� u- -j �0 1 W a--� �1�� �2 ®TtLE0 oui 08 Ix CONTRIBUTING ROOF LOAD WIDTH (1RIBUTARY AREA) (SEE SCHEMATIC LAYOUTS ON SHEET #1 FOR DESCRIPTION) • CARRIER BEAM SIZES so, 6' 0" T 0' 8' 0" 9' 0' 10' 0' 11' 0" 12' 0' 13' 0' 14' 0' 15,00 16' 0" IT 0" 16 0' 19 0' 2 x 4 SNAP x.045 x.045 6' 3' (A) 5' 8' (A) 5' 3- (A) 4' II' (A) 4' 8' (A) 4' 5' (5) 4' 2' (B) 4' 0' (15) 2 x 3 TUBE x.093 x.093 1' 0' (A) -6' T (A) (o' 0- (A) 5' 8' lA) 5' 4' lA) 5' 1' (B) 4' 10' (15) 4' 1' (13) 4' 5' eB) 4' 3' (B) 4' 1' lB) 2 x 4 LAP x.045 x.100 8' 0' (A) T 4' (A) 6' 9' (A) 6' 4' (13) 6' 0' (5) 1. 5' 8' (5) 5' 5' (B) 5' 2' (13) 5' 0' (B) 4' 9' (B) 4' 8' (B) 4' W (B) 4' 4' (B) 4' 3' (B) 4' I' (B) 2X5LAP x.0Wx.116 9' II' (A) 9' 1- (B) 8' 5' (15) T 10- (B) T 5' (B) T 0' (5) 6' 8' (15) 6' 5' (13) 6' 2- (C) V II- (C) 5' 9' (C) 5' T (C) 5' 5' (C) 5' 3' (C) 5' 1' (C) 2x6LAP x.050x.120 11'4- (5) 10 5' (B) 9' l' (B) 9' O' (B) 8' 6' (B) 8' 0' (C) T 8' (C) T 4' (C) T I' (C) 6' 10' (C) VT(D) 6' 4' (D) 6' 2' (D) 6' 0' (D) 5' 10' (D) 2x5TUBEx.125x.125 ell' T (5) 10' 10' (13) 10' 0' (R) 9' 5' (B) 8' 10' (C) 8' 5' (C) 8' 0' (C) T 10' (C) T 4' (C) T I' (D) 6' 10' (D) 6' 8' (D) 6' 5' (D) 6' 3' (D) (0' 1' (D) 2 x 7 LAP x.057 x.120 12' II' (B) 11' 9' (13) 10' 11' (B) 10' 2' (C) VT (C) 9' 1' (C) j 8' 8' (C) 8' 4' (D) 8' 0' l0) T 8' (D) T 5- (D) TV (D) TO' (D) 6' 10' (D) 6' 7' (D) 2x8LAP x.072x.224 14' l' (B) 13' 4' (C) 12' 4' (C) II' 6' (C) 10' 11' (D) 10' 4' (D) 9' 10' (D) 9' 5' (0) 9' 1' (D) 8' 9' (D) 8' 5' (D) 6' 2' (D) T 11' (D) T 8' (D) T 6' (E) - 2 x 9 LAP x.082 x.308 21' 8' (D) IV 9' (D) 18' 4' (D) 11' 1' (D) 16' 2' (E) 15' 4' (E) 14' T (E) 14' 0' (E) 13' 5' (F) 12' 11' (F) 12' 6' (F) 12' 1' (F) II' 9' (F) II' 5' (F) II' I' (F) 2 x 10 LAP x.092 x.389 -24' 4' (D) -22' 10' (D) 21' 6' (E) 20' 2' (E) IS' 0' (F) 18' 0' (F) 11' 2' (F) 16' 5' (P) 15' Y (F) 15' 3' (F) 14' 8' (F) 14' 3' (F) 13' 9' (G) 13' 5' (G) 13' 1' (G) DBL. 2 x 9 LAP x.062 x.306 625' 0' (E) 23' 9' (E) #22' 8' (F) Q1' 10' (F) 1 021' 1' (F) 020' 5' (F) IV 9' (6) IT 0' (G) 18' 4' (G) Il' 8' lG) 11' 1- (H) 1 16' T (H) 1 16' 2' (H) 15' 8' (H) DBL.2x10LAP x.092x.389 30' T (1-) -28' 10' (F) #21' 4' (F) 26' 2' (F) -25' 2' (F) 124' 4- (G) -23' T (G) ,22' 10- (H) -22' 3- (H) 21' 6' (H) 20' 9' (H) 20' 2' (H) 19' 6- (H) 19' 0' (H) 18' 6- (I) TABLE NOTES: 1. C) DENOTES DIMENSIONAL VALUES THAT ARE DEFLECTION -LIMITED (AS PER F.B.C. 2004), ALL OTHER DIMENSIONAL VALUES ARE STRESS -LIMITED. 2. THE LETTERS SHOWN IN PARENTHESIS CORRESPOND TO THE "FOOTER PAD KEY" (SEE BELO", AND REPRESENT THE MINIMUM FOOTER PAD SIZES NEEDED TO RESIST THE IMPOSED UPLIFT LOADS, AS DETERMINED BY ROOF TRIBUTARY AREA AND COLUMN SPACING (BASED ON A DESIGN UPLIFT LOAD OF 24 P.S.F.) 3. ANY SITE -SPECIFIC PARAMETERS THAT EXCEED THE VALUES INDICATED IN THIS TABLE SHALL BE REDIRECTED BACK TO THE ENGINEER OF RECORD FOR ADDITIONAL SITE -SPECIFIC STRUCTURAL ANALYSIS AND DESIGN. 4. THE DIMENSIONAL VALUES INDICATED IN THIS TABLE REPRESENT THE MAXIMUM ALLOWABLE CENTER -TO -CENTER LOCATION FORT HE PRESCRIBED VERTICAL SUPPORT COLUMNS PLACED UNDER ANY OF THE GIVEN CARRIER BEAMS. ®® A a� FOOTER PAD KEY. . MINIMUM COLUMN SIZE ALL CONC. ANCHORS SPECIFIED IN THIS TABLE SHALL BE RED+IEr1D °TRUBOLT WEDGE ANCHOR (SEE NOTE, SHT #1) MINIMUM CNTR-TO-CNTR DISTANCE MAXALLOW. LOAD (PER ANCHOR) (TENSION) SEE ANCHOR DETAIL# (SHEET #6) NUMBER AND SIZE Or THRU-BOLTS FOR CARRIER BEAM -TO - COLUMN CONNECTION NUMBER OF CONC. ANCHORS ANCHOR SIZE MINIMUM EMBED. MINIMUM EDGE DIST, SYMBOL FOOTER PAIL SIZE HAD 2' 0' SQUARE x 2 0' DEEP 3' x 3' x .125" COLUMN TWO (2) 3/8' DIA, 3" 3' W 1,176 LBS # 1 TWO (2) 318' DIA. BOLTS "BH 2' W SQUARE x 2 0" DEEP 3' x 3' x .125" COLUMN TWO (2) 31W DIA. 3' 3' 6' 1,176 LBS # 1 TWO (2) 318" DIA. BOLTS lien 2' 6" SQUARE x 2' 6' DEEP 3' x 3' x .125' COLUMN TWO (2) 30 DIA. 4" 3' 6" 1,340 LBS # 2 TWO (2) 31W DIA. BOLTS "Du V 0' SQUARE x 2' 6" DEEP 3' x 3° x .125" COLUMN TWO (2) 1/2' DIA. 41ff 3114' 61/4' 1,787 LBS # 3 THREE (3) 3/8" DIA. BOLTS "E. T 0" SQUARE x T 0" DEEP 3' x 3' x .125" COLUMN -TWO (2) SM' DIA. 51/W 4' 6' 2,140 LBS # 4 THREE (3)1/2' DIA. BOLTS Hp T 6" SQUARE x V W DEEP 4' x 4' x .125" COLUMN TWO (2) 3/4' DIA. 6 5/8' 5' r 2,900 LBS # 5 THREE (3) 518" DIA. BOLTS "Ga Y 6" SQUARE x 3' 6" DEEP 4" x 4' x .25W COLUMN FOUR (4) 1/2' DIA. 411W 31/40 61/4" 1,787 LBS # 6 FOUR (4)1/2" DIA. BOLTS "H° N 0' SQUARE x Y W DEEP 4" x 4' x .2W COLUMN FOUR (4) 5/8' DLk 51/8" 4' 6° 2,140 LBS # 7 FOUR (4) 518' DIA. BOLTS N 0' SQUARE x N W DEEP 4' x 4' x .250" COLUMN FOUR (4) 3/4' DIA. 6 5/8' 50 10' 3,580 LBS # 8 FOUR (4) 3W DIA. BOLTS Hill 4' 3" SQUARE x 4' V DEEP 4' x 4' x IV COLUMN FOUR (4) 314' DIA. 6 5V 5' 10° 3,580 LBS # 8 FOUR (4) 314' DIA, BOLTS ALL FOOTER PADS SHALL HAVE #5 BARS (WITH 3-INCH MINIMUM CONCRETE COVERAGE AT EACH END), PLACED AT S-INCHES CENTER TO -CENTER, IN EACH DIRECTION, TO BE PLACED 6 INCHES ABOVE THE BOTTOM OF THE FOOTER PAD (TYPICAL FOR ALL FOOTER PADS). BEAM SPLICE LOCATION SCHEMATIC (VERTICAL SUPPORT SPACING) � ACTUAL 125% OF ACTUAL TYP. SPACING I COL. SPACING REAP ALLOWABLE SPLICE TYP. CARRIER TYP. 3/16' LOCATION OPTIONS BEAM / 1/4' THIC TYPICAL SUPPORT COLUMNS PLATE Fnrr API ICFA nN A SMB- CARRIER BEAM. THE ACTUAL TYP. 3/16' / 1/4' THIC PLATE STITCH SCREWS SHALL BE 014 TFKS ® IS' O.C., TYP. BOTH TOP AND BOTTOM FLANGE OF ALL SM.B. CARRIER SEAMS SINGLE S.M.B. CARRIER BEAM STITCH SCREWS SHALL BE "14- TEKS to 18' O.C., TYP. BOTH TOP AND BOTTOM FLANGE OF ALL 5M.B. CARRIER BEAMS TWO INNER HALVES OF DOUBLE — BEAMS SHALL BE ATTACHED WITH TWO ROWS OF %4 TEKS 0 18' O.C., EACH TO BE STAGGERED FROM THE OTHER RCW, 50 THERE WILL BE ONE SCREW EVERY NINE INCHES OVERALL. (CONT. OVER ENTIRE LENGTH OF BEAM) STITCH SCREWS SHALL BE 014— TEKS a 18' O.G., TYP. BOTH TOP AND BOTTOM FLANGE OF ALL 5M.13. CARRIER BFAMS 1pc�lmlpj_ op 12' PLATE WIDTH (a D 6' ALL SCREWS SHALL 1- 2' 2' 2- 2' I' BE 014 TEK SCREWS I I iw 0 0 01 =� ^ '0 0 0 0 0 0� CARRIER BEAM SPLICE DETAIL (FOR 2 x 6 SEAMS AND SMALLER) USE 3116" THICK PLATE FOR THIS APPLICATION z r, W m SPLICE PLATE TOLERANCE NOTE: 1 ALL SPLICE PLATES (ALUMINUM ALLOY 06063-T(o or 0606146) SHALL. BE CUT TO BE +0.000 / -0.0625, AS INDICATED IN THE SCHEMATIC DRAJING5 AT LEFT 12' PLATE WIDTH Lui w= 6' 6' t0 m D ALL SCREWS SHALL i z I° 2' 2' 2' 2' I' BE q4 TEK SCREWS �Y w LU 0 0 0I Qn 10 0 0 01 �a to 0 0 0 0 0I BEAM SPLICE CARRIER SEAM SPLICE DETAIL (FOR 2 x 7 SEAMS AND URGER) USE 1/4" THICK PLATE FOR THIS APPLICATION SPLICE ON EACH HALF OF THE BEAM MUST BE POSITIONED IN A DIFFERENT LOCATION (BOTH SPLICES SHALL NOT NOTE: THE5E CARRIER SEAM SPLICE SPECIFICATIONS ALSO APPLY TO CARRIER 5EAMS UTIL.IZI=D WITH A 6GREEN WALL BE IN THE SAME LOCATION) ul w 910O(2:: Wlifl CD m� � 0 0 >Lu � OI N O UJI ma LLj 0 O CD w w LL g 3M*z = OP � z a� 0 a ch :3wz e� tn. T � Ill y LLI zig-gar 0 a u- . 0 ® al O Fe cd aj W y a 1/4' DIA. THRU-BOLT, WITH FENDER — WASHER ON TOP SURFACE AND NUT AND WASHER ON BOTTOM, TO BE PLACED AT 8 INCHES O.C. (SIX (6) BOLTS PER 4-FOOT WIDE ROOF P-ANEL, MINIMUM) INSULATED ALUMINUM INSULATED ALUMINUM ROOF PANEL (TYP) ROOF PANEL (TYP) 0 1/4' x 4' LAG SCREW W/ FEND 0 WASHER (HOLE TO BE PILO' 0 DRILLED WITH A 5/32' BIT), ' 112 TEK SCREWS W/ 5/8, DIA. (MIN.) WASHER AT 3' O.C. (4 PER 12-INCH WIDE PAN) 3-INCH RISER PAN - ROOF PANEL (TYP) 2 x 2 x .125 ANGLE (CONT.) BE INSTALLED is 8' O.C. (SIX (6) ATTACHED TO 2 x 3 x .090 LAGS PER 4-FOOT WIDE PANEL) CARRIER BEAM WITH TWO ROWS OF 014 TEKS, EACH ROW LOAD-BEARINGSCREEN WALL AT 18 INCHES O.G. (EACH ROW COLUMN (BEYOND) (SEE COL - SHALL BE STAGGERED, SO EACH TEK 15 9 INCHES APART) NOTE: FOR APPLICATION W/ LOAD -BEARING SCREEN WALL COLUMN (BEYOND) (SEE COL- UMN-TO-CARRIER BEAM DETAIL FOR SPEC.'S CN THIS CONNECTION) LOAD -BEARING SCREEN WALL CONT. 2 x 2 ANGLE, STRAPS SHALL BE PLACED ON THE UMN-TO-CARRIER BEAM DETAIL FOR SPEC.'S ON THIS CONNECTION) 3- INCH RISER PAN COLUMN (BEYOND) (SEE COL- OUTSIDE OF THE ANGLE (AS RAI ORSPPFC S ONTHISCONNECTION) SHOWN) INSULATED PANEL W/ LACE BOLTS INSULATED PANEL W/ THRU BOLTS ALUMINUM ROOF PANEL -TO -SCREEN WALL CARRIER 5EAM CONNECTION DETAIL5 2 x 2 x 3/16' ANGLE, WITH FOUR (4) P12 TEKS INTO THE UPRIGHT AND ONE (1) 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) SIDE I x 2 OB BOTTOM FRAME I x 3 OP SIDE -WALL CORNER UPRIGHT &I FLOOR LEVEL PLAN VIEW I x 2 x 1/8' ANGLE 0 INCHES 2 x 3 x .090 CARRIER LONG) WITH THREE (3) 012 TEKS INTO SIDE OF 3 x 3 x .010 COINEUPRIGHT AND THREE (3) 012 TEKS INTO THE BACK OF THE CARRIER BEAM, TYPICAL BOTH ON THE INSID AND OUTSIDE OF EACH 3 x 3 CORN UPRIGHT UPRIGHT 010 x 2' SMS SCREW, WITH 5/8' DIA. WASHER (SEE GENERAL NOTE 03, SHEI=T 02) TO 19E IS - INCHES, CENTER- TO -CENTER MAX. SPACING FRONT WALL I x 2 OB BOTTOM FRAME 2 3/4', MIN. ED 1315TANCE 3 x 3 x 210 FRONT WALL CORNER UPRIGHT 2 x 2 x 3/16' ANGLE, WITH FOUR (4)12 TEKS INTO THE UPRIGHT AND ONE lU 3/8' RED -HEAD 'TRU-BOLT' WEDGE ANCHOR (MIN. OF 4-INCH EMBEDMENT INTO THE CONCRETE) I x 2 OB BOTTOM FRAME w "10 x 2' SMS SCREW, WITH 5/8' DIA WASHER (SEE GENERAL w z NOTE 03, SHEET 02) TO BE IS- z a INCHES, CENTER -TO -CENTER N MAX. SPACING THICK STRAP, I�/z' WIDE x 6 INCHES LONG, WITH THREE l3) "12 TEKS INTO FACE OF CARRIER BEAM AND THREE l3) "12 TEKS INTO FRONT OF THE 3 x 3 x 010 CORNER UPRIGHT 3 x 3 x .010 }YRONT WALL CORNER UPRIGHT 2 3/4% MIN. 0 o 1 DISTA ELEVATION VIEW CORNER SPECIFICATION5 3-INCH RISER ROOF PANEL l 012 TEK SCREWS W/ 5/6' (MIK) WASHERS, TO BE INSTALLED WITHIN 2 INCHES ON EITHER SIDE OF EA. COLUMN AND 6 INCHES O.C„ MAXIMUM SPACING, INTO 2 x 3 H TOP SCREEN FRAME NOTE: BOTTOM OF COLUMN CONNECTION IS THE SAME FOR EITHER TYPE OF ROOF SYSTEM. WITH 3 INCH RISER PAN 1/4' x 4' LAG SCREW W/— FENDER WASHER HOLE TO BE PILOT DRILLED W/ A 5/32' BIT, LAGS TO BE INSTALLED WITHIN 2 INCHES ON EITHER SIDE OF EA. COLUMN AND 8 INCHES O.C. MAXIMUM SPACING, INTO 2 x 3 H TOP SCREEN FRAME 2x3x.010HTOP — SCREEN FRAME (TYP. ALL RETURN (SIDE) WALL PANELS) 2 x 2 x 3/16' ANGLE (21— LONG) WITH FOUR (4) q2 TEKS INTO SIDE OF COLUMN AND ONE (1) %' RED HEAD TRUBOLT WEDGE ANCHOR (3 INCH EMBED, MIN.), TYP. ONE ANGLE ON EACH SIDE OF EA. RETURN WALL COLUMN INSULATED ALUMINUM ROOF PANEL (TYP) 2x2x1/8'ANGLE (3' LONG) WITH FOUR (4) 012 TEKS INTO BOTTOM 0 o OF 2 x 3 H TOP FRAME AND FOUR (4) 112 TEKS INTO SIDE OF 2 x COL. (TYP_ ONE ANGLE ON EACH SIDE OF EACH RETURN (SIDE) WALL COLUMN) 2 x 5 SCREEN WALL COLUMN (MIN. FOR RETURN (SIDE) WALL APPLICATIONS AO I x 2 BASE SCREEN FRAME (TYP) M E 33/4 EDGE OF CONCRETE MIN WITH INSULATED PANEL RETURN (SIDE) WALL CONNECTION SPECIFICATIONS 0 0 0 ROOF FASTENER LENGTH NOTE: WHEN THICKER INSULATED ROOF PANELS ARE UTILIZED, THE FA5TENR5 USED OT BOLT THEM [DOWN SHALL BE AS FOLLOWS: 4-INCH THICK PANEL - 1/4" x 6' LAGS OR THRU-BOLTS 6-INCH THICK PANEL - 3/8' x l' LAGS OR THRU-BOLTS NOTE THAT FATENER SPACING SHALL REMAIN THE SAME AS THAT WHICH IS SPECIFIED FOR THE 3-INCH THICK PANELS 2 x 2 x 1/8' ANGLE (3 INCHES 2 x 3 x .090 CARRIER LONG) WITH 51X (6) 12 TEKS BEAM (CONT.) (SEE INTO SIDE OF 2 x 5 COLUMN 3/8' O I 10 TlIoo CARRIER BEAM SPLICE AND TWO (2) DIA. THRU 1®o II ®I DETAIL' IF OVERALL BOLTS (W/ NUT AND WASHERS) LENGTH OF BEAM THROUGH ANGLE AND CARRIER o REQUIRES A SPLICE) BEAM (TYP ONE ANGLE ON o EACH SIDE OF EACH FRONT 0 I/8' THK. STRAP, 11/7' WIDE x 6-INCHES LONG, WALL COLUMN) (SHOWN HERE WITH THREE (3) 012 TEKS INTO THE FACE OF BEHIND THE CARRIER BEAM) THE CARRIER BEAM AND THREE (3) #12 TEKS INTO THE FRONT OF THE 2 x 5 SMB UPRIGHT 2 x 5 FRONT WALL COLUMN (TYP. EACH COLUMN - TO - CARRIER BEAM (MIN, COLUMN SIZE FOR CONNECTION, INCLUDING 3 x 3 x .010 H FRONT WALL APPLICATION) CORNERS) FRONT VIEW (COLUMN 4 CARRIER BEAM) SEE 'ALUMINUM ROOF PANEL - TO -SCREEN WALL CARRIER BEAM CONNECTION DETAIL' FOR THESE SPEC.'S 2 x 3 x .OSO CARRIER — BEAM (CONT.) (GEE 'CARRIER BEAM SPLICE DETAIL' IF OVERALL LENGTH OF BEAM REQUIRES A SPLICE) 1/8' THICK STRAP, I1/2'— WIDE x 6 INCHES LONG, WITH THREE (3) 012 TEKS INTO FACE OF CARRIER BEAM AND THREE (3) rig TEKS INTO FRON- 2 x 5 COLUMN (TYF COL. -TO -CARRIER CONNECTION, INCLU 2 x 2 CORNER COLI 3x3x210HCHA 2 x 5 FRONT WALL ( fMIN. COLUMN SIZE I FRONT WALL APPLI I x 2 BASE SCREEN FRAME(TYP) EDGE OF CONCRET 0 0 SECTION VIEW 2 x 2 x 1/8' ANGLE (3 INCHES LONG) WITH SIX (6) 12 TEKS INTO SIDE OF 2 x 5 COLUMN AND TWO (2) 4e' DIA, THRU BOLTS (W/ NUT AND WASHERS) THROUGH ANGLE AND CARRIER BEAM (TYP. ONE ANGLE ON EACH SIDE OF EACH FRONT WALL COLUMN TOP OF FRONT WALL COLUMN SHALL BE NOTHCED l2' x 3') TO RECEIVE 2 x 3 x .090 CARRIER BEAM (TYP.) I x 2 TOP SCREEN FRAME (TYP.), ATTACHED TO BOT OF CARRIER BEAM WITH h0 SMS. (AS PER GEN. NOTE 03 ON SHEET U 2 x 2 x 3/16' ANGLE (2' LONG) WITH FOUR (4) 012 TEKS INTO SIDE OF COLUMN AND ONE (U %' RED HEAD TRUBOLT WEDGE ANCHOR (4 INCH EMBED, MIN.), TYP. TWO ANGLES ON EACH SIDE OF EACH FRONT WALL COLUMN (ONE ON TOP OF I x 2 SCREEN FRAME AND ONE DIRECTLY ON THE CONCRETE, TO THE INSIDE OF THE COLUMN, TO MAINTAIN A 3-INCH CNTR-TO-CNTR DISTANCE ON THE TWO CONCRETE ANCHORS ON EACH SIDE OF THE COLUMN) FRONT (VERTICAL LOAD SEARING) WALL CONNECTION 5PECIFICATION5 ~ w 8 Q co C i�LLw®F� �Qw U- '" 1140 ® �wU. w p op m w w ®�W�oa�c m 8 LL en i z � Lu Q w -., w Lu z 25 Im :3 co U9 1/4' x 211/2' LAG (W/ WASHER) Is 7 16' O.C. MAX. (ONE LAG SHALL BE INSTALLED INTO EACH 7- GUTTER INSERT) H05T STRUCT. FASCIA (TYP) SEE 'FASCIA ATTACH - EXTRUDED 1/8' Z-GUTTER INSERT (CUT 9 4' LONG) TO BE PLACED 32' O.C. (AT EVERY OTHER LAG) �/4' x 4' THROUGH BOLT, W/ FENDER WASHER ON TOP SIDE, TO BE INST- ALLED 9 8' O.G. (SIX PER 48-INCH .,, PANEL) THROUGH 2 x 4 ANGLE INSULATED ALUM. ROOF PANEL (TYP) MENT NOTE ON SHT. wl 012 TEK, TYP. 3 PER Z- GUTTER INSERT 2 x 3 x .0133 ANGL 2 x 4 x 1/8' ANGLE (CONT.) WITH SPACER (CONT.) 1/4' x 11/4' THROUGH BOLTS o 12' AS NEEDED FOR O.C. (ONE BOLT THRU EACH Z- ANGLED FASCIA, W/ GUTTER INSERT). ANGLE TO BE TWO ROWS OF 112 RAISED ENOUGH TO CLEAR N2 TEK SCREWS a 18' TEK6 IN TOP OF GUTTER O.C. (EACH ROW TO 3/8' x 8' LAG, PLACED THROUGH BE STAGGERED) A 3/4' x 3/4' FERRULE INTO FASCIA 5' STRUCTURAL GUTTER lT0 BE PLACED ®32' O.C., MAX) (CONT.) (TO ALSO PASS THRU 2 x 4 ANGLE) (PILOT -DRILL FASCIA W/ 1/32 BIT) FASCIA WITH STRUCT. GUTTER (INSULATED PANEL) HOST STRUCT. FASCIA (TYP) SEE 'FASCIA ATTACH-,,,.-,,., MENT NOTE' ON SHT. NI 1/4' x 21/2' LAG (W/ WASHER) 6 16' O.C. MAX. (ONE LAG SHALL BE INSTALLED INTO EACH I x 5 ANGLE) —I x 5 x 1/8' ANGLE (CUT 4 INCHES LONG). PLACE ANGLE CLIPS AT 32' O.C. (AT EVERY OTHER LAG) N2 TEK SCREWS W/ 5/8' DIA. (MIN.) WASHER AT 3' D.C. (4 PER 12-INCH WIDE PAN) WITH TWO 1`12 TEKS (MIN.) INTO EACH 1 x 5 ANGLE CLIP 3-INCH RISER PAN 2 x 3 x .O93 ANGLE ROOF PANEL (TYP) SPACER (CONT.) AS NEEDED FOR 3/e' x 8' LAG, PLACED THROUGH ANGLED FASCIA, W/ A 3/4' x 3/4' FERRULE INTO FASCIA TWO ROWS OF 112 (TO BE PLACED 4a 32' O.C., MAX) TEK SCREWS ® 18' 5' STRUCTURAL GUTTER (TO ALSO PASS THRU 2 x 4 ANGLE) O.G. (EACH ROW TO (CONT.) (PILOT -DRILL FASCIA W/ 1/32 BIT) BE STAGGERED) FASCIA WITH STRUCT. GUTTER (3-INCH RISER PAN ALUMINUM ROOF=TO=FA5CIA J WITH STRUCT. CUTTER '/4° x 2'/2' LAG, W/ WASHEF' MOBILE HOME SUB-FRAI' STRUCTURE 9 12' D.C., MA EXIST. HOST 1`10511_E—� HOME (SEE NOTE BELOW RE: FOURTH WALL INSTALLATION) 23/e' x 31/4' x 11/2' ALUM. ROOF HFApER (CONT) 3-INCH RISER PAN ROOF PANEL (TYP) 012 TEK SCREWS W/ 5/8' DIA. (MIN.) WASHER AT 3' O.C. (4 112 TEKS a 4' O.G. (3 PER J ' PER 12-INCH WIDE PAN) 12-INCH WIDE PAN) INTO BOTTOM OF PAN5 AND CARRIER BEAM (SIZED FROM ONE (U 012 TEK INTO THE CARRIER BEAM TABLE) TOP OF EACH RISER (IF ACCE55 TO THE TOP OF THE RISER 15 LIMITED, "12 TEKS MUST BE INSTALLED a 3' O.C. (4 PER 12-INCH WIDE PAN IN THE BOTTOM FOURTH WALL CONNECTION WITH 3-INCH RISER PAN `4' x 2�/2' LAG, W/ WASHE(' '•'�" MOBILE HOME SUB-FRAP STRUCTURE ® 12' O.C., MA EXIST. H05T MOBILE -- HOME (SEE NOTE ABOVE RE: FOURTH WALL INSTALLATION) 012 TEKS A 12' O.C. (4 PEF 48-INCH PANEL) INTO TC AND BOTTOM OF PANEL; (WHERE ACCESS TO TOP OR BOTTOM 15 RESTRICI 012 SHALL BE INSTALLED e (o' O.C. IN ONE SURFACE OR THE OTHER) 23/s' x 31/4' x I1/2' ALUM. ROOF HEADER (CONT) HOST STRUCT. FASCIA ITYP) SEE 'FASCIA ATTACH-� MENT NOTE' ON SHT. N 1/4' x 21/2' LAG SCREW (W/ WASHER), TO BE INSTALLED a Iro' O.C. (MAX.) /— INSULATED ALUM. / ROOF PANEL (TYP) Ix2x.MANGLE . SPACER (CONT.) AS NEEDED FOR N2 TEKS s 12' O ANGLED FASCIA, W/ 48-INCH PANE TWO ROWS OF N2 AND BOTTOM O TEK SCREWS a IV (WHERE ACCES O.G. (EACH ROW TO OR BOTTOM 16 BE STAGGERED) 92 SHALL O.0BE I IN ON OR THE OTHER FASCIA (INSULATEIp PANEL) C. (4 PER L) INTO TOP F PANELS 5 TO TOP RESTRICTED, NSTALLED E SURFACE 23%, x 31/4' x 11/2' ALUM. 1/4' x 21/2' LAG SCREW ROOF HEADER (CONT) (W/ WASHER), TO BE H05T STRUCT. INSTALLED ® 16' O.C. FASCIA (TYP) (MAX.) B-INCSEE'FASCIA ATTACH ROOF PANERISEL PAN 1 � ROOF PANEL (TYP) MENT NOTE' ON wl I x 2 x 2133 ANGLE SPACER (CONT.) AS NEEDED FOR —N2 TEK6 a 4' D.G. (3 PER ANGLED FASCIA, W/ 12-INCH WIDE PAN) INTO TWO ROWS OF 012 BOTTOM OF PANS AND TEK SCREWS o 16' ONE (U 012 TEK INTO THE O.C. (EACH ROW TO TOP OF EACH RISER (IF BE STAGGERED) ACCE55 TO THE TOP OF THE RISER IS LIMITED, 012 TEKS MUST BE INSTALLED to 3' O.C. e4 PER 12-INCH WIDE PAN IN THE BOTTOM FASCIA (3-INCH RISER PAN) ROOF PANEL (TYP) HOST 5TRUGT. WALL(TYP) ONE lU 1/4' x 21/2' LAG,' TO BE PLACED INTO EA. STUD (FOR WOOD FRAME) (MAXIMUM 24' O.C.) FOR CONIC. / C.B.5., FASTNER SHALL BE 3/s' DIA. RED- HEAD 'LDT' TAPCON, W/ A MIN. EMBEDMENT OF 13/4' INTO GONG. / C.B.S. WALL a 18' O.C. (MAX) 23/s' x 31/4' x I/2' ALUM. ROOF HEADER (CONT) INSULATED ALUM. ROOF PANEL (TYP) 012 TEKS is 12' O.C. (4 PER 48-INCH PANEL) INTO TOP AND BOTTOM OF PANELS (WHFRF ACCESS TO TOP OR BOTTOM 16 RESTRICTED, 012 SHALL BE INSTALLED is 6' O.C. IN ONE SURFACE OR THE OTHER) WALL. (INSULATED PANEL) HOST STRUCT. WALL (TYP) ONE (U 1/4' x 2�/2' LAG,--/ TO BE PLACED INTO EA. STUD (FOR WOOD FRAME) (MAXIMUM 24' O.C.) FOR GONG. / C.B.S., FASTNER SHALL BE 3/s' DIA. RED- HEAD 'LDT' TAPCON, W/ A MIN. EMBEDMENT OF 13/4' INTO GONG. / C.B.S. WALL a IS' D.C. (MAX) 23/8' x 31/4, x 11/2, ALUM. ROOF HEADER (CONT) 3-INCH R15ER PAN ROOF PANEL (TYP) N2 TEK6 ® 4' O.C. (3 PER 12-INCH WIDE PAN) INTO BOTTOM OF PANS AND ONE (1) 12 TEK INTO THE TOP OF EACH RISER (IF ACCESS TO THE TOP OF THE: RISER 15 LIMITED, N2 TEKS MUST BE INSTALLED 9 3' O.G. (4 PER 12-INCH WIDE PAN IN THE BOTTOM WALL (3-INCH RISER PAN) 5TANDARD ALUMINUM ROOF - TO - H05T STIRUCTURE CONNECTION DETAIL 23/s' x 31/4' x 11/2' ALUM. ROOF HEADER (CONT) 1/4' x 4' LAG SCREW W/ FENDER WASHER (HOLE TO BE PILOT - DRILLED WITH A 5/32' BIT), TO BE INSTALLED 4s 6' O.C, (SIX LAGS PER 48-INCH WIDE PANEL) (IF BEAM 15 A SM.B., SEE ANGLE ATTACHMENT DETAIL, TO BE USED WITH S.M.B. CARRIER BEAMS) CARRIER BEAM (SIZED FROM CARRIER BEAM TABLE) FOURTH WALL CONNECTION WITH INSULATED ROOF PANED FOURTH -WALL CONNECTION [DETAIL FOURTH WALL INSTALLATION NOTE: IF THE MOBILE HOME MANUFACTURER WILL PROVIDE WRITTEN AUTHORIZATION THAT THE MOBILE HOME WILL RESIST THE ADD- ITIONAL LOADS (LIVE, DEAD OR UPLIFT) IMPOSED BY THE ALUM. ROOF STRUCTURE, THE FOURTH WALL CARRIER BEAM AND COLUMNS MAY BE OMITTED (ORIGINAL DOCUMENTATION MUST ACCOMPANY THE PERMIT PAPERWORK SUBMITTED BY THE INSTALLATION CONTRACTOR). FOURTH WALL DE5f6N NOTE: IN THIS FOURTH WALL DE51GN, THE FOURTH WALL BEAM AND COLUMNS ARE IN PLACE TO RESIST THE IMPOSED LIVE LOADS, DEAD LOADS AND ALL UPLIFT LOADS IMPOSED 13Y THE ALUMINUM ROOF STRUCTURE. THE ATTACHMENT TO THE EXISTING HOST MOBILE HOME ONLY SERVES TO PROVIDE LATERAL STABILITY TO THE STRUCTURE. THIS DESIGN ALSO APPLIES IF THE CARRIER BEAM(S) ARE PERPENDICULAR TO THE HOST STRUCTURE, WHERE THE END OF THE BEAMS) SHALL BE SUPPORTED BY VERTICAL COLUMNS, THE ROOF HEADER SHALL STILL BE ATTACHED TO THE MOBILE HOME, AS 15 INDICATED ABOVE. ~ W p 00 LuLu ® 2 a -- co Z �j9Y0U. F- J ® LU U- W o0l W W O �Ww In z o ® 0 w � Q ICix EWL_u C3 ;EFt9Li�w8 � • nQ c r- zaQ' )-�Q sc) ui O d � u°3 cm le a PLAN VIEW 3 x 3 x 1/8' COLUMN - (6063-T6J 6' CNT -TO I1/2' CNTR DIST. Lu cO� EDGE OF CONCRETE Q r PLAN VIEW -TWO (2) 3/8' DIA. THRU 3 x 3 x 1/8' COLUMN BOLTS W/ WASHERS (606346) ON EACH END -3' x 3' x 3/b' STRUCT. ANGLE (3' LONG) (06061-T6), TYP ONE ANGLE ON EA. SIDE OF COLUMN i 3/a' DIA. RED -HEAD TRU50LTWEDGE ANCHOR (TYP. 2 PLACES) SECTION VIEW ANCHOR [DETAIL. #1 PLAN VIEW 4 x 4 x I/o) COLUMN (6063-T6) t- z w F Q m w TWO (2) 3j4' DIA. THRU BOLTS W/ WASHERS ON EACH END 3' x 3' x 3/s' STRUCT. ANGLE (4' LONG) (06W-T(o), TYP ONE ANGLE ON EA. SIDE OF COLUMN —3/4' PIA. RED -HEAD TRUBOLT WEDGE ANCHOR (TYP. 2 PLACES) SECTION VIEW ANCHOR DETAIL 15 w U w� M Q PLAN VIEW TWO (2) 3/a' DIA. THRU 3 x 3 x 1/8' COLUMN BOLTS W/ WASHERS (6063-T(b) ON EACH END 3' x 3' x 3/8' 5TRUCT. ANGLE (3' LONG) ("6061-T(o), TYP ONE ANGLE ON EA. SIDE OF COLUMN V DIA. REDHEAD TRUBOLTWEDGE ANCHOR (TYP. 2 PLACES) SECTION VIEW ANCHOR DETAIL #2 u U Q PLAN VIEW 3 x 3 x 1/8' COLUMN TWO (2) 5/8' DIA. THRU TWO (2) 1/7' DIA. THRU (606346) BOLTS W/ WA6HER5 BOLTS W/ WASHERS ON EACH END ON EACH END 3' x 3' x 3V STRUCT. 3' x 3' x 3/s' STRUCT. ANGLE (3' LONG) ANGLE (3' LONG) (%061-T6), TYP ONE (16061-T6), TYP ONE ANGLE ON EA. SIDE ANGLE ON EA. SIDE OF COLUMN OF COLUMN Q 1/2' DIA. RED -HEAD TRUBOLT WEDGE u�� ANCHOR (TYP. 2 PLACES) SECTION VIEW ANCHOR [DETAIL #3 WELDED CONNECTION NOTES: I. ALL WELDED COMPONENTS 514ALL BE WELDED ON ALL OUTER EDGES. 6U55TES SHALL RE WELDED ON BOTH SIDES OF EACH GUSSET. 2. ALL WELD5 SHALL BE 1/4', FULL -PENETRATION FILLET WELDS ISEE GEN. NOTE NUMBER SIX ON SHEET I FOR ADDITIONAL SPECIFICATION5) o �d EDGE OF CONCRETE FLAN VIEW 4x4x1/4'C (6063-T(o) /z' DIA. RED-HEAI TRUBOLT WEDGE ANCHOR (TYP. 4 PLACES) c14J � Q O Q wA - EDGE OF CONCRETE PLAN VIEW 4 x 4 x 1/4' COLUMN (60(03-T6) THICK PLATE MATL. 5/8' DIA. RED -HEAD 61-T6) TRU50LT WEDGE ANCHOR (TYP- 4 PLACES) SECTION VIEW ANCHOR DETAIL #(o 3/8' THICK PLATE MATL. (6061-T(o) ZQ SECTION VIEW ANCHOR DETAIL. #1 z Q 5/a' DIA. RED -HEAD u TRUBOLT WEDGE �m ANCHOR ITYP. 2 PLACES) SECTION VIEW ANCHOR DETAIL #4 EDGE PLAN VIEW 4 x 4 x 1/4' COLUMN (6063-T6 ) 3/8' THICK PLATE MATL. ITYP. BASE PLATE AND GUSSETS)(6061-T(o) F 3/4' DIA. RED -HEAD TRUBOLT WEDGE s ANCHOR (TYP. 4 PLACES) SECTION VIEW ANCHOR DETAIL 08 ~ w � p O z c!) W CD M38 an Lu C7 U. ir O Cam' L a! Z t IL LL —�+coZ O EL Q w a �c!)j5 C93 o(DW(j3 Lu ow0 ®8 RI W8 ua©FT cf) z I= O >ti o o b c d r H W 0�� i Lu o L U mm,., ��-)� 0 w f 032-BRAKE-FORMED RIDGE CAP W/ 12 TEKS (W/ 5/8' DIA. WASHERS) AT 11' D.C. FOR INSULATED ROOF AND INTO EACH RISER FOR PAN ROOF (TYP., CONTINUOUS), WITH MIN, OF 8-INCH LAP ONTO THE ROOF PANELS ON EACH SIDE 3-INCH RISER PAN ---- ROOF PANEL (TYP) 114' DIA. THRU BOLTS (WITH A 8' O.C. (MAX) THROUGH BOTH HEADERS ON EACH SIDE OF RIDGE BEAM 23/s' x 31/4' x 11/2' ALUM. ROOF HEADER WITH I x 2 x .053 ANGLE SPACER (CONT.) AS NEEDED FOR GABLE PITCH WITH TWO ROWS OF %2 TEKS 6 18' O.C. (EACH ROW TO BE STAGGERED) TYP. EACH SIDE OF RIDGE BEAM —INSULATED ALUM. 012 TEKS 0 4' O.C. (3 PER [j ROOF PANEL (TYP) 12-INC14 WIDE PAN) INTO BOTTOM OF PANS AND 012 TEK5 ® 12' O.C. (4 PER ONE (1) 012 TEK INTO THE 48-INCH PANEL) INTO TOP TOP OF EACH RISER (IF AND BOTTOM OF PANELS ACCESS TO THE TOP OF (WHERE ACCESS TO TOP THE RISER 15 LIMITED, 012 OR BOTTOM 15 RESTRICTED, TEK5 MUST BE INSTALLED 112 SHALL BE INSTALLED g 3' O.C. (4 PER 12-INCH ® 6' O.C. IN ONE SURFACE WIDE PAN IN THE BOTTOM OR THE OTHER) NOTE: THE MAXIMUM PITCH FOR THIS GABLE ROOF INSTALLATION DESIGN SHALL BE 3 : 12 (I40 SLOPE). TYPICAL GA5LE ROOF DETAIL M2 TEK SCREWS W/ 5/8' DIA. (MIN.) WASHER AT 3' O.C. (4 PER 12-INCH WIDE PAN) 3-INCH RISER PAN ROOF PANEL (TYP) TUBE -TYPE CARRIER BEAM (FROM CARR.. BEAM TABLE) 3-INCH R15ER PAN WITH TUBE BEAM 1/4' x 4' LAG SCREW W/ FENDER WASHER (HOLE TO BE PILOT - DRILLED WITH A 5/32' BIT), TO BE INSTALLED 9 8' D.C. (SIX LAGS PER 48-INCH WIDE PANEL) INSULATED ALUM. ROOF PANEL (TYP) TUBE -TYPE CARRIER BEAM (FROM CARR. BEAM TABLE) NOTE: THE 2 x 2 CONT. ANGLE ATTACHMENT MAY BE USED WITH THE TUBE -TYPE CARRIER BEAM, IF THE CONTRACTOR CHOOSES TO UTILIZE THAT TYPE OF INSTALLATION. INSULATED ROOF PANEL WITH TUBE BEAM NOTE: WHEN INSTALLING A 3-INCH RISER PAN ROOF SYSTEM ON A SM.B.-TYPE CARRIER BEAM, THE 012 TEKS SCREWS THAT ANCHOR THE ROOF PANS TO THE TOP OF THE CARRIER BEAM MAY ALSO 'ACT AS THE STITCH SCREWS FOR THE TOP FANGE. OF THE SM.B.- TYPE CARRIER BEAM 3' WIDE x 3' LONGER THAN CARRIER BEAM HEIGHT x 3/16' PLATE (EX.: FOR 8' TALL BEAM, PLATE SHALL BE 3' x II') BOTTOM 3 INCHES OF PLATE- THA LAPS ONTO SIDE OF 3 x 3 COLUMN SHALL HAVE FOUR (4) 114 TEK5 THRU THE PLATE AND INTO THE SIDE OF THE COLUMN �$NALL BE 22' FOR. 5HALL BE I° FOR 4 x 4 x l/8' CQCUMN; `S1X� NUMBER AND SIZE OF -NUMBER AND O = ;,'' THRU-BOLTS (FR THRU-BOLT5 (FROM 'FOOTER PAD;,K�Y' -' 'FOOTER PAD KEY' TABLE). BOLTS SHALL' TABLE). BOLTS SHALL HAVE WASHERSiON HAVE WASHERS ON BOTH ENDS AND PA65 BOTH ENDS AND PASS ;; THROUGH THE NOTCHED? THROUGH BOTH SIDES COLUMN, TH5`GARR[ER` " " OF THE NOTCHED COLUMN _- BEAM AND THE 3/Ib'' PLATE ON TMErOTf tkf '' SIDE AS WELL (TY4-) }' -3 x 3 x 1/6' COLUf�N 3 x 3 x .125 COLUMN 3 x 3 COLUMN WITH s 3-x 3 COLUMN WITH OFFSET NOTCH -' CENTER NOTCH STANDARD COLUMN - 012 TEK SCREWS W/ 5/6' DIA. (MIN.) WASHER AT 3' O.C. (4 PER 12-INCH WIDE PAN) 3-INCH RISER PAN WITH S.M.B. BEAM -14° x 4' THROUGH BOLT, W/ r;:ri " WASHER ON TOP SIDE, TO BE 11' ALLED s 8' O.C. (SIX PER 48-ID PANEL) THROUGH 2 x 3 ANGLE 2 x 3 x US' ANGLE (CONT.) WITH TWO ROWS OF 14 TEK5 ® IV 0.( (MAXJ, EACH ROW SHALL BE STAGGERED SO THERE 15 A TEI SCREWS EVERY 8 INCHES 3-INCH RISER PAN ROOF PANEL (TYP) .-TYPE CARRIER BEAM M CARR BEAM TABLE) INSULATED ALUM. ROOF PANEL (TYP) 3.-TYPE CARRIER BEAM :)M CARR BEAM TABLE) NOTE: THE PILOT DRILL AND LAG SCREW (W/ FENDER WASHER) ATTACHMENT MAY BE USED FOR SM.B.-TYPE CARRIER BEAMS THAT ARE 2 x 8 AND LARGER ONLY (SM.B: TYPE CARRIER BEAMS 2 x l AND SMALLER MUST UTILIZE THE 2 x 3 ANGLE ATTACHMENT). INSULATED ROOF PANEL WITH S.M.B. BEAM ALUMINUM ROOF - TO - CARRIER 5E,AM CONNECTION [DETAIL NOTE: 1/4' THICK PLATE MAY BE CUT FROM THE SIDE WALLS OF A SCRAP PIECE OF 4 x 4 x 1/.? COLUM 4 x 4 x 1/8' COLUMN — (MINIMUM FOR DOUBLE CARRIER BEAM) 4' WIDE x (HEIGHT SFE>CIFIED AT LEFT FOR DOUBLE CARRIER BEAMS) x 1/4' WICK PLATE; TYPICAL ONE M EA04 SIDE OF COLUMN -TO -BEAM CON- NECTION. THE NUMBER AND Silo OF T:HRJ BOLTS (AS SPECIFIED IN THE 'FOOTER PAD (KEY' TABLE) SHALL BE IN67ALLlED BOTH' THROUGH THE DOUBLE BEAM AND THE COLUM BELOW(IF TABLE SPECIFIES FOWR rri' DIA. BOLTS FOR CARRIER BEAM -TO - COLUMN CONNECTIOK, THERE MUST BE FOUR: WILTS THROUGH THE BEAM AND Fa R BOLTS THROUGH THE Ca71 Uh Y 4 x 4 COLUMN WITH DBL. ?� CARRIER BEAM T GARRIEP, BEAM CONNECTION DETAILS r - {F` ;;'NOTE: FOR INSTALLATION ON A WOOD -FRAMED H05T 5TRUUCTURE, w THE CARRIER SEAM SHALL BE POSITIONED 50 THAT ONE OF THE TWO AMLES (ON EITHER SIDE) ANCHOR INTO THE STUD -FRAMING IN THE WALL OF THE HOST STRUCTURE. J V x 3' x 1/4' THK. ANGLE 06063-T(o) CUT 8 INCHES LONG, TYP_ ONE ON - EACH SIDE OF CARRIER BEAM :=s=R 7-TOP rOP u Z 3/8' DIA. THRU BOLTS M/ WASHER VIEW - ON EACH END), T P.TWOI PER CONNECTION 3/8' DIA. RED -HEAD 'LDT' TAPCCN. WITH MIN. EMBED INTO Ca5. WALL OF 13/4' (INTO ACTUAL BLOCK),. TYP. Yr,s TWO 3/6' LDT'5 PER ABLE (FOUR k= TOTAL PER CONNECT[OW : TYPICAL CARRIER BEAM E SI:pE a F (SIZED FROM CARRIER VIEW o BEAM TABLED N -' s c0 — — — IF CARRIER BEAM 15 LE55 THAN 6 INCHES N, HEIGHT, t° i �'Q- m ANGLES MAY BE TRIMMED ;r' _ SU OFF AT ANGLE (AS SHOWN) CARRIER SEAM - TO = MOST �TRUGTURE TYPICAL CONNECTION [DETAIL SPECIAL, DE51GN NOTE: THE LOAD CAPACITY FOR 1, ;115 'CARRIER BEAM -TO -HOST STRUCTURE' CONNECTION DETAIL 15 3,000 LBS ($HEAR). WHEN A JOB SITE CONDITION CALLS FOR A CARRIER BEAM (EITHER FLAT ROOF OR GABLE ROOF) TO ATTACH TO A HOST STRUCTURE (OTHER THAN FOURTH WALL, WHERE THE LOAD WILL BE PREDOMINANTLY SUPPORTED BY THE'VERTICAL COLUMNS), THE ENGINEER OF RECORD MUST REVIEW THE SITE -SPECIFIC PLAN FOR PLACEMENT OF SUPPORT COLUMNS, TO ENSURE THAT THE TRIBUTARY AREA LOAD ON THE END OF THE CARRIER BEAMS) DOES NOT EXCEED THIS- SPECIFIED LOAD CAPACITY H it W W Mw w c) Wmo �Quj � 03 caz U. O F L u- -cnco!�O Qw � ui 03 00 LucoW� O � Lu co to t� ®Lu�®w0 �F®-rzlz0 to yj z ® f:�- o RE t-u L) M � � a =NE