Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSSCANNED BY St. Lucie County Permit Number: O —,AW7 St. Lucie County Building & Zoning Department 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-1553 APPLICATION FOR STORM SHUTTER PERMIT SECT I , „ I TWP I -a L/ I RNG I ^ MAP SEE REVERSE SIDE FOR INSTRUCTIONS ' DATE: 1. LOCATION/SITE ADDRESS: 2. PARCEL ID NUMBER: Z LI I q " wo t — co cl:�)'l — 0 00 — LU 1 n ne I INIT A-- Fief Ca, FL 34gy9 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: S 4. TYPE OF STRUCTURE: SFR X Addition OTHER M W 5. OWNERS INFORMATION 6. C Name: f Od a E FL REG/CER #1 . T A Address: 25 T 1 �cae L COUNTYCE b ,tegeMerl is City: FO(� i f State: G Business Name: St. L C.�1pieGic , •• Phone: Zip. 3I E ed f _sownineowr�ef777 L')Vv_. Type of Surface attachment: Wood Frame _ Concrete MasoiGs ' 7 ; , ¢Other Product Type Minimum Design Pressure Product Compliance Report # Methodof"Stfdchment As per 1707.4.4.1 FBC 120 mph 130 mph 140 mph 140 Exp. C SBCCI Dade Other Anchor Type Anchor Spacing Impact Glazing Removable Panels Accordion Roll U Colonials Other t1LL rllUll U%-10 0KILAJ L DL' LH13LL'L Alfl.l.r UK DAME UgJUIN'I Y rUK UE-ILA KAIMI1NG IMFAUI• RESISI•ANCE FROM WIND BORNE DEBRIS. **SEE FINAL INSPECTION PROCEDUREK. FOR EXISTING RESIDENTIAL STRUCTURES ON BACK. 7. VALUE OF CONSTRUCTION: $ 16''FEES DUE: RECEIPT: OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. 1' PRINT QUALIFIERS/OWNERS NAME S[GNATURE OF QUALIFIER/OWNERZ1. STATE OF FLORIDA, COUNTY OF bt -Lucie ACKNOWLEDGED BEFORE ME THIS _ DAY OF ./� b t_. ,2 WHO IS PER ON LLY KNOWN TOME OR WHO HAS PRODUCEDI'i321D-391-51-10%-DAS IDENTIFICATION. SIG TURF OF NO T NAME OF NOTARY T NOTARY PUBLIC „y.�..., KARENT. SCO C M SSION NUMBER MY COMMISSION # DD 72790 , NOTICE TO OWNER: YOUR FAILURE T gqt 7 0 E E i y SWI 1�G�ioi��86IN0$Y G TWICE FOR IMPR Y €_�; S RA d11144414C G, CONSULT WITH Y ENDER OR AN ATTORNEY BEF COMMENCEMENT. - INSTRUCTIONS Please complete all information in the space provided. All information must be Printed (use black or blue ink only) or Typed. This application for Shutters to be used for only those activities that is not otherwise included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition to the installation of Shutters, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. LOCATION/SITE ADDRESS :.............................................. Indicate the street address, or general location, of the property on which the building activity is taking place. 2. PARCEL ID NUMBER: ........................................................ Indicate the Property Tax Identification Number for the property on which the building activity is taking place. 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY........ Briefly describe the building activity under permit application. 4. OWNERS INFORMATION: ................................................ 5. CONTRACTORS INFORMATION: .................................... 6. VALUE OF CONSTRUCTION: ........................................... Indicate the name and address of the owner of the property on which the product is to be installed. Indicate the State of Florida (if applicable) and St. Lucie County contractor's registration numbers, and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. The value of construction is used to determine the amount of permitting fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. All applications for the installation of Shutters are to be submitted to the St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Following the issuance of this Shutter Permit, the scheduling of all required inspections may be made by calling (772) 462-1261. INSPECTIONS ** EXISTING RESIDENCES All shutters must be installed and in place at the time of the final inspection, except for Egress Windows and Doors where one panel must be installed and the remainder must be by the opening for the inspector to verify remaining panels. ON NEW HOMES ALL SHUTTER PANELS MUST BE INSTALLED AT TIME OF FINAL INSPECTION OR INSPECTION WILL FAIL AND C.O. WILL NOT BE ISSUED. SLCCDV FORM NO: 006-05 r co T St. Lucie County Building & Zoning Department 2300 Virginia Avenue Fort Pierce, Florida 34982 (772)462-1553 OWNER/BUILDER AFFIDAVIT DISCLOSURE STATEMENT F.S. 489.103 (7) EXEMPTIONS State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must provide direct, on -site supervision of the construction yourself. You may build or improve farm outbuildings, a one -family or two-family residence or a commercial building at a cost of under $25,000.00. The building or residence must be for your own occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a building you have built or substantially improved your self within one year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building; it is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Initial ON I understand that the building official and inspectors are not there to design or give ad a onhow to meet the minimum code. Initial I understand that as an owner -builder that any contract disputes with sub -contractors and I must be handled in a civil court with the advice of an attorney. This department will not mitigate any contract di pute,, nitial I understand that if I compensate any person or company for work performed they are required to be licensed in this jurisdiction. If for some reason they do not possess a license, I may be responsible a d 'able for the cost of the license. Initial Gl I understand that if any person that is unlicensed and uninsured gets injured on my construction project - they may be entitled to workmen's compensation. I could be held liable for all doctor, lawyer and related medical cost, which could include loss of wages during recovery from their injury. Initial To qualify for this exemption under this subsection, an owner must personally appear and sign the building permit application and initial the above. I hereby acknowledge that I have read and understand the above disclosure statement and that I further understand that any violation of the terms of the owner/builder exemption shall be reported by the Building and Zoning Department to the Florida State Department of Professional Regulation. Signed and acknowledged on this 'day of of 20 Obi. X6l Owne /Bu'r der�l�Si-'°"t re STATE OF FLORIDA COUNTY OF. Sir . l-IJCIP_ The foregoing instrument was acknowledged before me this day of 200Z by ffiS A0 W "WP- le( ?0A who is personally known to me or has produced 7ature -N -as identificationof Notary Type or Print Name of Notary (Seal) Title: Notary Public Commission NumberM711 q l *I MY COMMISSION # DO 727904 EXPIRES: November 17, 2011 . ,fly Bonded Thru Notary Publio Undor dtors Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucieco.gov/ce Issued: 07/03/2008 Job Location: 2503 ROYALT ST Permit Type: Storm Shutter Job Description: BUILDING PERMIT Conf #: 550 Permit #: SLC- 0807-0097 City: FORT PIERCE INSTALLATION OF HURRICANE SHUTTERS ON 11 OPENING FOR SINGLE FAMILY RESIDENCE Page 1 S/D Seminole Park S/D Lot: 13 Block: 3 Parcel: 2419-601-0051-000/9 Owner Builder MAE ELLEN SANDERS Property Owner Setbacks Left: 2503 ROLYAT STREET FORT PIERCE, FL 34947 MAE E SANDERS 2503 ROLYAT ST Number of Units: •1.00 Minimum Floor Elevation: (772) 465-5035 (772) 465-5035 FORT PIERCE, FL 34947-5323 Right: Front: Rear: Zoning: CO Floors: 1 Buildings: 1 Square Footage: 0.00 Flood Map: Flood Zone: Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from. other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. Page 1 of 1 Building Details Parcel ID: 2419-601-0051-000-9 Card Number: 1 Account Number: 27524 Code Description Area Perimeter BAS - BASE 1049 148 AREA OP2 - OPEN 20 24 PORCH 20 OP3 - OPEN 176 54 PORCH 30 UT6 - 84 38 UTILITY/60 http://www.paslc.orglbasearea.asp?sketch=\27000\524001.jpg&account=27524&card=l &p... 5/8/2008 Florida Building Code Online�� - , Page 1 of 3 BCIS Home , Lo Hot�T plcs ubMit Sure g t s acts Publications FBC Staff B rodue -ppro ah USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail :. FL # FL22 1 - Application Type Re si n Code Version 0 Application Status proved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Town and Country Industries, Inc. 400 West McNab Road Ft. Lauderdale, FL 33309 (954) 970-7700 tomj@tc-alum.com Vladimir Knezevich KAEng@aol.com SOh, rsPanels Evaluation Report from a Florida RegiE Licensed Florida Professional Engineer Evaluation Report - Hardcopy RecE Vladimir John Knezevich PE-10983 http://floridabui lding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgtdytNblepz49QAM... 12/26/2007 Florida Building Code Online,-,, ,, -- Page 2 of 3 Quality Assurance Entity Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved mary of Products National Accreditation and Managemei ORLANDO L. BLANCO, P.E. Standard SSTD 12 Method 2 Option B 06/10/2005 06/10/2005 06/15/2005 06/30/2005 IIFL # Model, Number or Name IlDescrintion 2250.1 0232" and .0285" Galv Steel Storm Panels Limits of Use (See Other) Approved for use in HVHZ: Approved for use outside HVHZ: Impact Resistant: Design Pressure: +/- Other: Use of these product shall be in strict conformance with the requirements of the reference drawing prepared by TTG, Inc. and comply with chapter 61G15-23 of the Florida Administrative Code. These products are NOT suitable for installation in the High Velocity Hurricane Zone (HVHZ). This product may only be installed on concrete, hollow concrete block or wood substrates. For all other conditions site specific design shall be by this office or our delegated engineer. Panel spans less than those noted in the Minimum Panel Length Schedule of the reference drawings are not acceptable per the provisions of SSTD 12-99. " Deep x 12" Wide Corru Installation Instruction Verified By: Evaluation Reports PTID_2250_R1_T 05-32' PTID_2250_R1_Tu_05-32, PTID_2250_R1_T 05-35i http://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtdytNblepz49QAM... 12/26/2007 FloridaBuilding Code Online Page 3 of 3' 2250.2 and .060" .040' OS ' D p x 12" Wide Corru Alumintorm Panels Limits of Use (See Other) Installation Instruction Approved for use in HVHZ: Verified By: i Approved for use outside HVHZ: Evaluation Reports Impact Resistant: Design Pressure: +/- j Other: Use of these product shall be in strict conformance with the requirements of the reference drawing prepared by TTG, Inc. and comply with chapter 61G15-23 of the Florida Administrative Code. These products are NOT suitable for installation in the High Velocity Hurricane Zone (HVHZ). This product may only be installed on concrete, hollow concrete block or wood substrates. For all other conditions site. specific design shall be by this office or our delegated engineer. Panel spans less than those noted in the Minimum Panel Length Schedule of the reference drawings are not acceptable per the provisions of SSTD 12-99. Back I Next DCA Adminlstration Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Suncom 277-1824, Fax (850) 414-8436 O 2000-2005 The State of Florida. All rights reserved. Cooyright_and Disc. Product Approval Accepts: ��Bobby .��aao•.�_o http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz49QAM... 12/26/2007 o a 0 0 M I i c i r� zl I 1.05" MIN . (TY 1.17"�TE Sni No. 13 i 6.000" COVERAGE 8.332" 111� HALF STORM PANEL IUTTER SYSTEM DESIGNED SYSTEM IN ACCORDANCE 2 THIS SHUTTER SYSTEM HAS BEEN TESTED FOR LARGE MISSILE IMPACT RESISTANCE IN CONFORMANCE WITH THE SBCCI STANDARD SSTD 12-99 AND FOR UNIFORM STATIC AIR PRESSURE IN CONFORMANCE WITH ASTM E330-02. REFERENCED TEST REPORTS CONSTRUCTION TESTING CORPORATION (C.T.C.) TEST REPORT N.'s. 97-063. 98-009. 98-010. 98-011, 98-014, 99-044, 00-041, 00-022, 01-037 AND 02-012. 3. AN ALLOWABLE STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. 4. DETERMINE THE POSITIVE AND NEGATIVE DESIGN LOADS TO USE WHEN REFERENCING THESE DOCUMENTS IN ACCORDANCE WITH THE GOVERNING CODE AND GOVERNING WIND VELOCITY. 5. USE OF THESE PRODUCT EVALUATION DOCUMENTS ARE PREPARED BY THE PRODUCT ENGINEER AND ARE GENERIC. THEY DO NOT INCLUDE INFORMATION PREPARED FOR A SPECIFIC SITE. 6. USE OF THESE APPROVAL DOCUMENTS SHALL COMPLY WITH CHAPTER 61015-23 OF THE FLORIDA ADMINISTRATIVE CODE. 7. THESE PRODUCT EVALUATION DOCUMENTS ARE SUITARI F TO RE ARRI IFn RV TA B. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED. .060" 2.990" 2.250" .101" .0994" 1 .120 cH 62" U' HEADER ,�1 t .•))SCALE : 3" = V-0" f 1.525" STUD 1.-_5LY p, 700 DIRECTION ¶ .375" R 524" MAY BE REVERSED o .090" . o �.150 .215" I .215 .060" 1.00" MIN.090" l a V 315" R -.632" 5.00" MAX. SYM. OSTUD ANGLE O ANGLE O C-TRACK SCALE : 3" = V-0" SCALE : 3" = V-0" SCALE : HALF SIZE .376" .376" .190' .190' r 313" .452" 655" r 313" .452" .655" lJ 0.090" (TYP.) I ---'-------� 2.00" /LEG DIRECTION IS OPTIONAL 'F' TRACK F' ANGLE - TRACK CALE : HALF SIZE SCALE -•: HALF SIZE 440" 1 9. WHEN THE SITE CONDITIONS DEVIATE FROM THESE PRODUCT EVALUATION DOCUMENTS, SITE SPECIFIC DOCUMENTS SHALL BE PREPARED BY A DULY LICENSED AND REGISTERED ENGINEER OR ARCHITECT. SAID DOCUMENTS SHALL BEAR THE DATE, SIGNATURE 25 - .563"0 AND EMBOSSED SEAL OF THE DELEGATED ENGINEER OR ARCHITECT AND SHALL BE SUBMITTED TO THE PRODUCT ENGINEER FOR REVIEW. in 10. WHERE COMPLIANCE WITH SSTD 12-99 IS REQUIRED, PANELS SHALL BE PERMANENTLY I I "' LABELED WITH A MINIMUM OF ONE LABEL PER OPENING OR THE MANUFACTURER o eQ,, ry 30" Jo AND INSTALLER SHALL PROVIDE A CERTIFICATE OF COMPLIANCE. WHERE LABEL ARE USED, THE LABEL SHALL READ AS FOLLOWS: (7AMAC 3AU" (20 GA. GALV. STEEL GR 40 TOWN a4 COUNTRY INDUSTRIES INC. WASHERED FORT E TiACT WING NUT' (IAl1AlN) LAE ERDAEIMPACTRESBTANT OR 0.050' 6063-TS ALUM) KEYHOLE WASHER SSTD 12-99 9 R Q i� O 11. ALL SCREWS BOLTS AND WASHERS SHALL BE 2024-T4 ALUMINUM ALLOY �}S' ALE : HALF SIZE STAINLESS STEEL OR GALVANIZED STEEL WITH A MINIMUM TENSILE SCALE: HALF SIZE WIDTH UNLIMITE STRENGTH . OF 60 KSI U ON r �HANOLE INSIDE PERP TO PANEL S 12. TOP & BOTTOM DETAILS SHOWN MAY BE INTERCHANGED AS FIELD CONDITIONS'q -q DICTATE. PANELS MAY BE MOUNTED HORIZONTALLY IF C-TRACK, BUILD -OUT F-s i 2 TRACK, 'F' TRACK, 'F' ANGLE, STUD ANGLE OR DIRECT MOUNTED IS USED. e o R 13. STORM PANELS SHALL BE ALUMINUM ALLOY WITH THE FOLLOWING METAL'$ IR R THICKNESS: ®® mf 0.040' (3oo2402 4 4 0.06W 300/-H34 0 0 e 14. ALL EXTRUSIONS SHALL BE 6063-T6 ALUMINUM ALLOY, U.D.N. /'HANDLE STYLE 8cd -. / LOCATION OPTIONAL V gig PULL -IN PANEL PLAN VIEW EXTERIOR SIDE N.T.S. TYPYP. SECTIONS I 'U' HEADER 3" = I I .090" a,.215"��-y.215 090.1 YM .700' OC-TRACK SCALE :HALF SIZE 1/4-20 MACHINE SCREW (STUD DIRECTION MAY-0 19 BE REVERSED) I, .OBB" -Ty - YPHi I _.4 * 2.00" MIN. 5.00" MAX. D ANGLE kALE /�_LgMAX, `O i EXISTING CONCRETE, HOLLOW BLOCK OR WOOD FRAMING (TYP.) O WALL/ DIRECT MOUNT ALUM.ANGLE CLOSURE PIECE Q 1" x 2" x .125' MIN. TO 2" x 5" x AX' MAX. T 1/4"0 FASTENER @ 24" O.C. SEE ANCHOR SCHEDULE FOR ANY ACCEPTABLE ANCHOR O BUILD -OUT MOUNT TOP MOUNT Q� n�lili 111 ji i'li �jl!.'I!�II11IijI�III'j' 1 i ,IIII �I)I I I I II I- wwx �iil ji I I�i Ili ,iPLAN z»z, VIEW ma E Www =ter Ii, IIIII'I w�pl ,:) I Il�li I a�wz II II.;' I'i I I I u _ xiI I Hzaaw�Ijl rEli�il'I � iIIII I��II �a� III�I ,.I I',IIiI���I j � -20x1� vwwi� LI���IIJI! Ik!I' i WALK CUT CORNERS OF THE BOTTOM MOUNT T W/ PM PULL -IN PANEL TO CLEAR ITYP.) SPACE FOR WINGNUT OF TYPICAL VERTICAL ADJACENT PANELS MOUNT ELEVATION PULL -IN PANEL ELEVATION WT.S N.T.S. 1/8" MAX. ALUM. ANGLE CLOSURE PIECE 05 O 1" x 2" x .125" MIN. TO MAX�2" x 5" x .125" MAX.MINEMB. N xx OVERLAp_�i - .. ffl/� V �-1/4" 0 FASTENER @24" O.C. SEE ANCHOR Z SCHEDULE FOR ANY Q ACCEPTABLE ANCHOR J O TRAP MOUNT m TYPICAL CLOSURE DETAILS (PLAN) SCALE: 1-1/2" = V-0" 0 LL t 05 350 k a EXISTING CONCRETE, HOLLOW BLOCK OR WOOD FRAMING (SEE ANCHOR ' PENETRATION SCHEDULE BASED ON TYPE OF OR EMBED, Cl CONNECTION TYPE STRUCTURE) REFERENCE ANCHOR ITYP. I SCHEDULE FOR MAX. SPACING OS SHORT LEG MAY 1/2 BE RIVERFED TOWARDS THE OPENING 1/4" MAX. w GLASS OR DOOR OPTION 1 ENGINEER MAY X w HEADER ONLV DETERMINE ACCEPTABLE BUILD OUT WHILE MAINTANING� #14 TEK SCREW Q m GLASS C S N-PO20U5 CONDITIONS. OR 1/4-20 1 is MACHINE SCREW Q DOOR — w •OPTION 5-1/8" CLEARANCE TO � Qa O4 GLASS OR DOOR REQUIRED, 2NO.CUT E J J UNLESS SIDE CLOSURES L o ARE PROVIDED, THEN, t 1a o w HEADER OR SILL NO SEPARATION FROM F W GLASS, REQUIRED. In N l7 F 7 O w Z BUILD OUT "' Q OPTIONAL m o - 9 O MOUNTING L7 M a EXTRUSIONS wwo w O 1/2•. (A w \ ` Cl CONNECTION 1/4-20 x 3/4" TYPE REFERENCE ANCHOR MACHINE SCREW EXISTING CONCRETE, SCHEDULE FOR MAX. SPACING EXISTING CONCRETE, HOLLOW BLOCK DR WOOD HOLLOW BLOCK OR WOOD FRAMING (SEE ANCHOR FRAMING (SEE ANCHOR SCHEDULE BASED ON TYPE OF SCHEDULE BASED ON TYPE OF STRUCTURE) — _ STRUCTURE) s EXISTING CONCRETE, HOLLOW BLOCK OR WOOD FRAMING (SEE ANCHOR PENETRATION SCHEDULE BASED ON TYPE OR EMBED. STRUCTURE) ITYP. Cl CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING IIZIU GLASS OR DOOR n J.. xw _j Q m d EQ 1 1a r w Z m a� E i0 K W 1 1a u VI VI wZ v Q 10 n •FASTENER @D 6" 0. . OR @ 12" O.C. ,BUT D NOT EXCEED ANCHOR SCHEDULE SPACING USE REMOVABLE ANCHORS ONLY WITH KEYHOLE WASHER. LOCATE FASTENER IN NARROW PORTION OF KEYHOLE WASHER Cl CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING WALL MOUNT SECTION VALE : 3" = 1'-0" C2 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING PENETRATION OR EMBED. Cl CONNECTION TYPE OF REFERENCE ANCHOR ( YP.` SCHEDULE FOR MAX. SPACING 09 USE6a IW/ 1/4-20 x 3/4" 7N MACHINE SCREW W/ .675" x .675" x .125" SQUARE SCREW HEAD 08 XW Q J Em E J Z I Q w aJ 1 1a I i p 0: W o= 9 H w N VI Z N 1/4" MAX w a w GAP 1/4-2 x 3/4" \ O4 MACHINE SCREW Cl CONNECTION TYPE 0 REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING EXISTING CONCRETE, HOLLOW BLOCK OR WOOD FRAMING ISEE ANCHOR SCHEDULE BASED ON TYPE OF STRUCTURE) OWALL MOUNT SECTION F SCALE • 3' _ 1'-0" EXISTING CONCRETE, HOLLOW BLOCK OR WOOD FRAMING (SEE ANCHOR SCHEDULE BASED ON TYPE OF PENETRATION STRUCTURE) PENETRATION OR EMBED. Cl CONNECTION TYPE OR EMBED. REFERENCE ANCHOR SCHEDULE FOR MAX. O w~ 2..x2..O a] wii plo'7 j Z CONT. GLASS OR Q C4 CONNECTION TYPE Og —Ei i D �- DOOR Oj is F p. REFERENCE ANCHOR O 3/4"OM W/ 1/ SCREW �. o = SCHED GE FOR MAX. 1 to N USE 6 W/ 1/4-20 x MAY BE RE RSED 9 z 1/4" MAX. w Q GLA55 OR W/ .675" x .675" x .125" f z o p ' � _ m a.Z DOOR SQUARE SCREW HEAD GLASSOR rJ `', GAP• N0. m 1 1a DOOR W W - EXISTING CONCRETE, w� fI ao HOLLOW BLOCK OR WOOD FRAMING (SEE ANCHOR WALL MOUNT SECTION z C) EXISTING CONCRETE, EQ. EO SCHEDULE BASED ON TYPE OF w¢ �� C3 CONNECTION TYPE HOLLOW BLOCK OR WOOD STRUCTURE) o. o REFERENCE ANCHOR FRAMING (SEE ANCHOR O SCALE : 3" = 1'-0" Q EQ. SCHEDULE FOR MAX. SCHEDULE BASED ON TYPE Of SPACING STRUCTURE) (THIS DETAIL MAY BE USED AT TOP AND BOTTOM) OCEILING/FLOOR MOUNT SECTION CEILING/FLOOR MOUNT SECTION WALL MOUNT SECTION SCALE 3" = 1'-0" O SCALE : 3" = 1`-0" O SCALE : 3" = 1'-O" BUILD -OUT MOUNT SECTION D C4 CONNECTION TYPE ALE : 3" = V-0" REFERENCE ANCHOR SCHEDULE FOR MAX. EXISTING CONCRETE, SPACING HOLLOW BLOCK OR WOOD FRAMING (SEE ANCHOR 1" 1" SCHEDULE BASED ON TYPE OF STRUCTURE) 1/4-20 x 3/4" Z w MACHINE SCREW _ ITYP.) M w l O 4a MAX. o 9 a X O7 to Q m i Q O QJ sm Q wH 0~ .- a•. �! NNECTION TYRE.�,C : • '11: IENCE ANCHOR ^UGE FOR MA)C O y/� O8 O O N Q 08 O V 2 9 Q 0 .I o THREE 1/4"mx MIN. 4" Z C4 CONNECTION TYPE r 1 o LONG WOOD LAG SCREWS TWO 1/4-Ox MIN, 4N LONG '- w USE 1/4" WOOD LAG SCREW OR - - [d 24" D.C. MAX. WITH 1-3/4" f 1'. 1/4" ELCO - HALE/FEMALE STAINLESS STEEL EMBEDMENT INTO WOOD W PpNELMATE REFERENCE ANCHOR WOOD LAG SCREWS I 1-1/2" 1-1/2" 24' O.C. MAX. WITH MEMBER \ i SCHEDULE FOR MAX. 1�-3/4" MIN. EMBEDMENT ! tO Il e WOOD ROOF TRU55 m I n OR FRAMING MEMBER i \ SPACING INTO EXISTING I A� _ I •-� v EMBEDMENT E SHALL BE PERPENDICULAR EXISTING STUDS j +� TO THE PANEL FACE 1." " x 4•' x 1/8'. WOOD FRAMIN y EXISTING STUCCO I \ FRAMING 3N x OR 4" x WOOD x CONT. ALUM. ,�C - ° I E- FINISH OR PLYWOOD FRAMING REQUIRED 1/2" TUBE SN` d 1/2" PLYWOOD c SOFFIT T.YP —p14 x 3/4" 1/4" 1/4'• 4 4 TE9"SCREW r _ MAX. EXISTING ,MAX. - 2" z 5" x 1/8" GLAZING w1/4" MAX �',• cA FI x CONT. ALUM. ��DD �I�, ANGLE OR 4'• 3 ?-�f �-N74x 3/4" �� LL g J ,; I y QeL lo� z 1/4" x CONT. TEK SCREW m V, ALUM. FLAT E �ETWEEN ' n EE MIN. STORM E Z J w m,�+ PANEL SEP. FROM `^ 0 TRUSSES �i -GLASS TABLE 2 a Q— LEE MIN. STORM 1 1a : O L ~ a _ PANEL SEP. FRO r GLASS TABLE 2 O o w EMBED MEN EXISTING m EMBEDMENT_,",` Z VI O GLAZING = N EXISTING w w I: (n1 Q GLAZING ��� III E C1 CONNECTION TYPE 1 9 _-- - - E SEE MIN. xl= ID Iu a�l $ REFERENCE ANCHOR 1a W i TWO 1/4"mx MIN. 4" LONG `�• _ STORM PANEL 9 1 1a Ela iqz = � � 6 SCHEDULE FOR MAX. w f ,n SEPARATION g l0 -N STAINLESS STEEL S. SPACING pIN FROM GLASS I .. z WOOD LAG SCREWS i-•a I y TABLE 2 C® 24" O.C. MAX. WITH iv = _f - _ - 4 4 1/4'• � o "T 1-3/4" MIN. EMBEDMEN ,`�' i z MAX. = I0�I_� EXISTING CONCRETE, \-' '^ HOLLOW BLOCK OR MB. IN CENTER OF STUDS i 7/4"mx MIN. 2-1/2" LONG ___ _ N WOOD FRAMING." .°' '.- STAINLESS STEEL.�i/4" MAX. �Q �Ei<�`• WOOD LAG SCREW C& 12" O.C. - I ba'� ah N EXISTING 2" x 6" P.T. CONT. W/ 1-3/4" EMBEDMENT I. C CONNECTION TYPE {� yF) GLASS WOO)BLOCKING- INTO WOOD BLOCKING \ m 1'. 1" REFERENCE ANCHOR }c� o W\. SCHEDULE FOR MAX. OHCEILING MOUNT/ BUILD OUT SECTION 7 to CEILJNC°/BUILD-OUT MOUNT SECTION SPACING a LIl 3" MAX. O BUILD-OOUT MOUNT SECTION SCALE: 3" = 1' - 0" 1 SCALE: 3" T - 0" I0 j I 0 z ' O SCALE: 3" = 1' - 0" IO Q I �I 1/4-20 MACHINE SCREW t i FRAMING MEMBER AND NUT Cm 12" O.C. MAX. BY OTHERS v 5" LONG HANDLE"J -• , RIVETED TO PANEL o L — "J 1" x 3" x 1/8" MAX. CONTINUOUS CI CONNECTION TYPE p_2- ,• I�1L 6063-T6 ALUM. REFERENCE ANCHOR a•.'•• 'ji I .0 1/4-20 S.S. BOLT SIDE CLOSURE DETAIL 1 1a SCHEDULE FOR MAX. 1- 1'I 3/B"� HOL•E FOR' �` �a/L •, j:/ & BOLT & WINGNUT O ALLOY ANGLE MAX. y F SPACING ASTENINf, (ip 1a Cb1 24" O.0 (TYP.1 SCALE• 3.� = 1�_O.. ----'------ —k C N 'i PUNCH 1/2" x 1" HOLES IN`^ LT B 7 o ADJACENT PANELS TO RECEIVE \H 0' m THIS BOLT W/ PM NUT. PLACE - 1(1a PANEL OVER EACH ADJACENT � , o •, / PANEL AND FASTEN WINGNUTS 'ENBED. 7, � •, R Ii -µI I y FROM THE INSIDE \\\ I '�'.<1s'•, 1 ,a E•N� �6_I• - i EXISTING - l—EXIS PING O9 TYP. EXISTING o f BAY WINDOW W N� W HOLLOW BLOCK 1/4-20 S.S. BOLT 90- TO 135- MAX. BEND. moo" r n & WINGNUT OR x 1 1a 1/4-20 SS STUDS 1 1a (MAX. PANEL HEIGHT o 7.4• & A'IAX. DESIGN LOAD 72.09P.S.F.) 0 glg W/ WINGNUT .. 12" O.C. (TYP,) O INTERIOR FASTENING ANGLE ASSEMBLY \\ .R SCALE: 1-1/2" = 1'-0" 0 1/BOL S.S. BOLT 1 CLOSURE ITYP.) 1/4-20 x 1" MACHINE Ia i & BOLT & WINP. SCREW STUD WITH Cm 24" O.C. (TYP. 1 to 4.. WASHERED WINGNUT Cal DETAIL,)BQN NOTE 20 GAGE STEEL MAX. ' 12" O.C. (CONNECTS THESE DETAILS DEPICT THE a BENT PLATE 1" OVERLAP .036" BARE METAL THICKNESS TO ADJACENT PANEL) CONNECTION OF THE LAST PANEL Z OR 2" x 2" x 1/w, STEEL CONFORMING TO ASTM A 653.. FOR AN OPENING WITH PANELS e WALL MOUNTED O SENT P6 ALUM. GRADE 33 (SO). G 60 GALVANIZED INSTALLED FROM INSIDE. USE r; BENT PLATE 4" COATING, OR .063" 3004-H34 S" x 2" x 1/8" x CONT. 2-1/2" x 1-1/4" OF THESE DETAILS SHALL BE IN "" O—gf2g/zp 5 - ALUMINUM ALLOY BENT PLATE. STUDDED ANGLE WIDE NOTCHES CONJUNCTION WITH AN "h' 'MAX. (SEE SECTION T) (TYP. BOTH SIDES) HEADER OR "U" HEADER TOP •AS NOTED ip""" Mca� E OTYPICAL CORNER CLOSURE DETAILS (PLAN) O tir 1' z K L 1' O OPTIONAL INTERIOR FASTENING DETAIL (ISOMETRIC) SCALE-1-1/2" = -0" N.T.S. ct 01 5 � sheet3 of 6 ANCHOR SCHEDULE FASTENER MAXIMUM SPACING (INCHES) REQUIRED FOR VARIOUS DESIGN LOADS AND SPANS LOAD MIN. 2" EDGE DISTANCE MIN. 3" EDGE DISTANCE' IW1 SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO ANCHOR TYPE P.S.F. MAX. (SEE NOTE 1) SEE NOTE 1 12'-0" (SEE NOTE 1) (SEE NOTE 1) 5'-0" (SEE NOTE 1) _ 8'-9" (SEE NOTE 1) 12'-0" (SEE NOTE 1) (SEE NOTE 1) � � (SEE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE NOTE 1) (SEE NOTE 3) C1C2C3C4�C5 (SEE NOTE 3) C11 C2�C31C4 CS (SEE NOTE 3) C1 C2�C31C4j CS (SEE NOTE 3 C1 jC2 C31C4 CS (SEE NOTE 3) C11C2 C3C4 CS (SEE NOTE 3) C1C2�C3IC4•CS (SEE NOTE 3) C1!C2i C3,Ct�CS (SEE NOTE 3) Ct; CII C3; C4 CS `� ti1717`p7mi7171717i71itR17rtfj1 33_0 18 18 12 14 ' 7 ' 8 11 i 8 t k7l _ U v j EE a I-LEi „V ~ O = i; C ?AID O cow h + = c <mL Iryl C 1 hI OJI �o o IQWI �Q o ? `8 oa 5s Ugh �N�I + o �Q H y Y^ poio GI C v ea 1031i `c jOQ�I m'i - //101 p� 1 4 t� i S B_20. 9,1 o Y18114.1C II Ivl III i 2 SEEPAGE 6 OF 6 FOR COMPLETE ANCHOR NOTES. f !t_o' Ll 0 j ''� 04!28!2005 E m AS NOTED aM'• NICk v ' 05-350 1 �l (( sheet4 Of 6 !3 0 n 0 E E It ANCHOR SCHEDULE FASTENER MAXIMUM SPACING (INCHES) REQUIRED FOR VARIOUS DESIGN LOADS AND SPANS fJ LOAD MIN. 2" EDGE DISTANCE MIN. 3" EDGE DISTANCE Q (W) P S F. SPANS UP TO 5'-0" SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO F- ANCHOR TYPE MAX (SEE NOTE 1) e'-9" (SEE NOTE 1) 12'-0" (SEE NOTE 1) 15'-0" (SEE NOTE 1) 5'-0" (SEE NOTE 1) e' 9" (SEE NOTE 1) 12'-0" (SEE NOTE 1) 15'-0" (SEE NOTE 1) (SEE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE W ul NOTE 1) (SEE NOTE 3) C11C2 C3'C41CS (SEE NOTE 3) C1 C2iC31C41C5 (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) C11C21C3lC4;C5 C11C2j C37C4105 C1jC2lC3!;C4iC5 C1 C21C3',C41C5 C1;C21C3'C4 C5 Ct'C2 C3 C4!C5 ��tt7t�t�tt���t7t1m111l1l1tt71tt�t�m���i�'�1�t71117t{7111� 33.0 17 13 1 8 9 9 1 7! 4 S 7 5 3 4 5 1 4 3 18 1 151 9 111 10 9 5 6 7 1 6 3 4✓ 6 5 3 `j .A1lllllllllllllW111llllllllllll'? 44.2 12 (t0 6 7 74 543 4 5 L 3 4 3 13 11 7 B 7 1 6 3 L 5 4A 3 .�j3-1 5 4 /� 3 1/4"0 ITW TAPCON 47.2 11 9 5 1 6 6 5 13 3- 4 3 +- 4 3, 13 111 6 7 7 6 3 4 55 43 5 4 Yi 3 W/ 1-1/4" MIN. EMBEDMENT 64.0 -- 800 8�6:415 1� 7,51314 53 4'3- 4 3 -'---7 9 814',5 5 4 3 _ -- 5 L 3 ..� 5 4 J L�,3 4+3� 43 716314� SIL: 3 3 S43' 11f1111t1rt11t111t�7�t��{1111��111t1{1111��1111t�R11f�1�T�f�l�t�t7--�� _17It111111l1lllSllll11111L111U1?> 33 44.2 18 18 1� 8 112 4 1811419 !11I/Z 16 110 1 7 161101618 12 7 1 5 1 6 13.815 11 7 ! 4 6 5 18178116118' --I- 18 1 18 !15 18!17; 11 13 18 13 8 1016 __ _ 10 6 e _ 1/4"0 ELCO 47 2 18 17 tt 13 15 9 �'6 7 17 7 4 5 77 7 4 1 5 118 . 18174 16 18 13 B) 10. 18112 8 '9 15 9 6 1- 7 r 14, 9 .. 6 7 13 8 5 6 _. ... t31 8 5 6_ TAPCON W/ 1-1/4" MIN. EMBEDMENT 64.0 __ 18 13 8 10 111 7 ! 4 5 _ L� 11 7 4 5 11 7 4 5 18 16' 10 - 12 -� 141 91_6 7 - 13 j 8 1 5 , 6 . 8 5 6 80.0 1611016!,8 11174'S 11 7 I 4t5, 11 7 4 5 181318 10 131815'6 13'85 j6 _13 13'e;5 6' Y * S�'.-i@.1r.CGm�9'4' 33A- 18 18112 74 17 10 7 8 12 7 S 6 10I 6 4 4 18 18 15 18 18' 73 8 t0 '✓ 16 9 6 �7 72 7 5 6 00 m ,l.rs,��b.3+-;±,� 1/4"0 "PANELMATE" 10 6 4 5 44.2 L7.2 18' 18 13 1 9 • 131 8 70 ' 70 13 12 7 i 5 7 4�_5 6 9 5 3 4 8 5 3 L 1B� 77 111� 13 76 9. 6 7 11 7 4 5 / ELCO MALE/FEMALE 6 1/4-20 MACHINE SCREW FOR FEMALE---. 64 0 15 1 B 5 3 4 8 5 3 4 18 16' 701! 12 75 9 j 6 7 11 6 ' 4 5 -1 101: 6- 4 5 f/ -1.r AND 1/4-20 WWN FOR MALE OR 1/4"0 _ 9 6 7r 9 5� 3' 4 8 5 3 4 1a: 8 5 1 3 L' 18 12 ' e 9 11 ; 677 5� 10r 6' 4 1 5' 10 . 6 ELCO ELCO CRETE FLEX W/ 1-1/4" MIN. EMBED. 80 0 12 1 7 5 6 8 S 13 1 4; 8! 5 3 4 8 5 3 4 15 19 j 6 1 7 10 j 6 4 j 5 70 j 6 4 5 70 ! 6. 4 5 O 0 33.0 18 18; 7416 18 1217 9 1418 5 6 11 7 415. 18 18 17118' 16�15 9 11' 15'11'7�8 12 9.5 6/ 1/4"0 POWERS ZAMAC 442 47.2 18 18 1 10 j 12 141 9 11 14 13 8 5 8 5 fi 6 10 1 6 9 4 5 9 5! 1�4 3 j L 16 18 12 75 75 11 7! 8 11 8 S 6 10 7 4 5 6 4 4 9 --, 5 18118 12' 14 14 10 6 8 11 ! B 5 5 - to 7 . 4 , 5 2 NAIL -IN W/ 1-1/8" MIN. EMBEDMENT 64 0 17 10 7 8 9 6 4 4 9 5 3 4 9 5 3 4 --�--�- 18 14 1 8 10 , 11 8{ 5 6 10i7 4 5 W 7 4 S 80.0 131 B S 6 9 + 1 5 1 3 1 4 9 5 1 3 4 9Y5 3 4 15� 11 7 8 10j 7 1 4 j 5� �_ 101 7 4 5 rf t0. 7 -4 -.9 =11I11I�IIlI[��lillll®�L- 33.0 18 16 11012 A1419 KI 617, 10 1 6415 81513i4 - 1 18 18; 15'18 --.__.� 18113 .'8 -10' 159167 --- - 12 7.5 6�✓� --_:._-- v/ 44.2 18 `12 8 9. 11 ! 6�i 44 S B S 1 3 3 7 1 4! 3 3 18 117 11 13 75 1 9 6 7 11 7 4~ 5 10 6 4 1'5 5/16"01TW XL TAPCON W/ 1-1/4" 47.2 78�11 718 1 101614 4 7 4!313 714 3 3 18; 16,10y12. 14�9116 7�10 y 6 45�10 6T4 5�/ w MIN. EMBEDMENT 64.0 131 B 1 5 6 7 4 3 3 7 4 1 33 7 4! 3 3 10 11 1 7 910 6 LL 5 10 6 4 5 10 6 c 5 J 80.0 10; 6 4 5 7 4 3 3 7 4 1 3 1 3 7 1 4! 3 1 3 75' 9! 6 1 7 t0 i 6 1 4 5 10 6 4 5 10 6 �c 5 MIN. 1.25" EDGE DISTANCE MIN. 2" EDGE DISTANCE 330 18115 ! 11 12 17' 9 j 671,21 i 10 5' 3 4 18 15 11 112 17 9 6 L7 72 6 4 5 70 3 4 1/4"0 442 47.2 18 Ill8 9 I� 181171 7 1 8 121 6 1 4 11 6 4 5, 8 4! 3 1 3 18 11 8 (9 12 1 6 4 S f r5 9 4 3 3 «5 8 4 3 3 ALL POINTS SOLID -SET ANCHOR W/ 7/8" EMBEDMENT 8 1/4-20 STAINLESS 64.0 15 8 1 S 6 1 e 4 3 5 I a 4 3 3 781 71' 7 1 8 711 6 L B4 9 13 8 4�3 3 STEEL MACHINE SCREW e ,�; 3 3 iS 8 5 6 8 4 3 3' 8 4 3 3 B 4 3 3, 80.0 12 6 4 5 8 1 4 3{ 3 8 4 1 3 1 3 12 !. 6 1 4 1 5 a t4 3y3 8 4 3 3 8: 4 3� 3 SEE PAGE 6 OF 6 FOR COMPLETE ANCHOR NOTES. 0 U-1 04/28/2005 ANCHOR SCHEDULE FASTENER MAXIMUM SPACING (INCHES) REQUIRED FOR VARIOUS DESIGN LOADS AND SPANS r; LOAD MIN, 3/4" EDGE DISTANCE (W) SPANS UP TO SPANS UP TO SPANS UP TO SPANS UP TO � P S F 5'-0" e'- 9" 12'-0'" 15'-0" ANCHOR TYPE MAX (SEE NOTE 1) (SEE NOTE 1) (SEE NOTE 1) (SEE NOTE 1) H y (SEE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE CONNECTION TYPE x Ol NOTE (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) (SEE NOTE 3) 1) C1,C2,C3,C4 C5 C1.C21C31C4j C5 CIjC2j C3'C4 C5 C1IC2!C31C4!C5 330 12:12.1212 12112 12 12 12112 10 101 12' 91 8 8 1/4"0 WOOD 44 2 --- 12 1 12 ; 12 • 12 --I---1-'-- 12 112 0 11 . 12 19 7 B 12- 8 6 7 LAG W/ t-27/32' MIN. THREAD 47.2 12 12 j 1271,12 '-t-, 12' 11 1 9 j 10' 12 -{ H 7 7 12 8 6 7 PENETRATION SMEAR PARALLEL OR PERP. -- 64 0 ------ ------r--- 12 12 t y2 12 --= -- --1-.{--�� 12 B 7 17 -- - - - 12 8 6 7 12 8 TO WOOD GRAIN 800 12'12;10�10 12181617� 1218 617 1218�6 7 * �•'''T"•-�' * 33.0 12 12 12', 12 12 112 110112 j 12 . 121 11 1 8 9 12 9 . 6 1 7 12 112 12+12 12 12 8_ 9 12 8 5 1 6 12 8 5 6 D ` 1/4"0 L4 2 C7 O ELCO MALE/ FEMALE •vaNELMATE• W/ 1-7/a" MIN. PENETRATION - - L7 2 12 12112 12 12 11 71 8 ' 12 8 5 6 12 8 _- 5 6 1 1/4-20 MACHINE SCREW FOR FEMALE 64.0 12 12 9 11 1 �- 8 5 1 6 12 B 5 6 12 8 5 6 - 12, 11 7 ! 9- AND1/4-20 W WN FOR MALE000 12 j 8 1 5 j 6 12 8 15 1 6 12 B S' 6 1 jTj[ 310 12 12 12 9 Ut 44.2 12 12 9 8 , 7116-0 WDOD BUSHING W/ 47.2 --- 12 11 , B g S/9• MIN. PENETRATION 1 1/4-20 SIDEWALK BOLT 64.0 ----- 12 - - 8 H B 80.0 12' 8 8 e ANCHOR NOTES: 1. SPANS AND LOADS SHOWN HERE ARE FOR DETERMINING ANCHOR SPACING ONLY. ALLOWABLE STORM PANEL SPANS FOR SPECIFIC LOADS MUST BE LIMITED TO THOSE SHOWN IN TABLE 1. 2 ANCHOR TYPE ANDHEDGEL DISTANCCE. SELECT DESIGN LOADUGREATER MATERIAL ANCHOR EQUAL TO NEGATIVE DESIGN LOAD ON SHUTTER AND SELECT SPAN GREATER THAN OR EQUAL TO SHUTTER SPAN, 3. EXISTING STRUCTURE MAY BE CONCRETE HOLLOW BLOCK OR WOOD FRAMING. REFERENCE ANCHOR SCHEDULE FOR PROPER ANCHOR TYPE BASED ON TYPE OF EXISTING STRUCTURE AND APPROPRIATE CONNECTION TYPE. SEE MOUNTING SECTION DETAILS FOR IDENTIFICATION OF CONNECTION TYPE. 4.. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. 5, MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES WALL FINISH OR STUCCO. 6 WHERE EXISTING STRUCTURE IS WOOD FRAMING WOOD FRAMING CONDITIONS VARY. FIELD VERIFY THAT FASTENERS ARE INTO ADEQUATE WOOD FRAMING SIDE B_LOS NOT PIEC S. WOOD. FASTENING TO PLYWOOD IS ACCEPTABLE ONLY FOR 7. WHERE LAG SCREWS FASTEN TO NARROW FACE OF STUD FRAMING FASTENER SHALL BE LOCATED IN CENTER OF NOMINAL 2" x 4" (MIN.) WOOD STUD. 3/4" EDGE DISTANCE IS ACCEPTABLE FOR WOOD FRAMING. WOOD STUD SHALL BE SOUTHERN PINE" G=0.55 OR GREATER DENSITY. LAG SCREWS SHALL HAVE PHILLIPS PAN HEAD OR HEX HEAD. 8. MACHINE SCREWS SHALL HAVE MINIMUM OF 1/2" ENGAGEMENT OF THREADS IN BASE ANCHOR AND MAY HAVE EITHER A PAN HEAD, TRUSS HEAD, OR WAFER HEAD [SIDEWALK BOLT), U.O.N. 9. ® DESIGNATES ANCHOR CONDITIONS WHICH ARE NOT ACCEPTABLE USES. 10. * DESIGNATES ANCHORS WHICH ARE REMOVABLE BY REMOVING MACHINE SCREW, NUT OR WASHERED WINGNUT. It FOR LOADS GREATER THAN THOSE SPECIFIED (ANCHOR SCHEDULE), SITE SPECIFIC FASTENER ANALYSIS SHALL BE PREPARED BY KNEZEVICH & ASSOCIATES, INC. 12. SEE THE APPROPRIATE SBCCI PST & EST OR NES EVALUATION REPORT ON THE SPECIFIC FASTENER FOR SPECIAL INSPECTION REQUIREMENTS WHEN REQUIRED AS WELL AS FOR INSTALLATION, LIMITATIONS & IDENTIFICATION PURPOSES. 13. FASTENER MAXIMUM SPACING ARE BASED ON FACTOR OF SAFETY OF 4:1 ON TENSION AND SHEAR.VALUES WITH THE EXCEPTION OF THE 1/4"0 WOOD LAG SCREW AND THE 7/16-0 WOOD BUSHING WHICH ARE BASED ON NOS REQUIREMENTS AND SBCCI TESTING REQUIREMENTS RESPECTIVELY. TABLE 1 STORM PANEL MAXIMUM SPAN HEDULE • NEGATIVE DESIGN LOAD W (P.S.F.) THI.=;K;IV E S 0.040° r 50° 0.060• ALL MOUNTING CONDITIONS EXCEPT -F" ANGLE TRACK ALL MOUNTING CONDITIONS EXCEPT "F" ANGLE TRACK ALL MOUNTING CONDITIONS EXCEPT "F" ANGLE TRACK L MAX. (FT - IN) L MAX. I (FT - IN) L MAX. (FT - IN) 30 11' 1" 11' - 9.' 14' - 11- 33 10, -7" 11'-2" 14, _3.. 35.8 10- - 2" 10- 9•. 13• _ 0.. 38.3 9' - 10" 10' - 4•' 13' --2" 40.7 9'-6" 10,-1" 12'-10" 44.2 9' - 1" 9• 8- 12• - 3" 4 8' 10" 9' - 4" 11• 019 8' 6" 9' - 0" 11' - 5" 52.4 - 8--4- 8' - 10" 117- 2" 56 8'-1" 8' -7" 10' -6" 60 7' - 10" 80 - 301 9' - 9" 68 7' - 4" 74 - 6" 8' - 7" 72 T - 1" 7. - 1" 8' = 2" 76 6' - 9" 6' - 90• 80 60- 5- TABLE 2 MINIMUM PANEL LENGTH SCHEDULE MOUNTING CONDITIONS MINIMUM PANEL LENGTH- (IN) TOP DIREtr C-TRACK MOUN RECES 'h" OR "U•EF-TRACK (6 OR 6a1 W/ SIDE C-TR HEADER CLPOSUREIECES DIRECT MOUNT OR RECESSED 52 30 - C-TRACK (6a) 2" x 2" STUD 36 30 35 30 31 - ANGLE F-ANGLE TRACK 57 31 90 31 62 - C-TRACK (6 OR 6a) 64 55 110 35 90 - F-TRACK 57 49 90 31 76 - C-TRACK (6 OR 6a) W/ SIDE CLOSURE PIECES TABLE 3 STORM PANEL WITH "F" ANGLE TRACK (TOP OR BOTTOM) MAX. SPAN SCHED. NEGATIVE DESIGN LOAD W (P. S.F ) THICKNESS 0.040° 0.050° 0.060• ALL MOUNTING CONDITIONS ALL MOUNTING CONDITIONS ALL MOUNTING CONDITIONS L MAX. (FT - IN) L MAX. (FT - IN) L MAX. (FT - IN) 30 11' - 1.. 11' - 91, 14• - 11" 33 10• - 7" 11' - 2" 124 - 11" 10" 10' - 4" 12' _ 7 407 9' 6" 1W 44.2 9' - 1" 9' - a, 10' - 6.. 47 2 8' - 10" 9- - 4 • 9- 10 - 50.9 8' - 6•' 9' - 0' 9• - 1" 52 4 8' - 4" 56 8' - 1" 8- 3.. 8' - 3" 60 7' -9.. 7' _ 9.. 7'_ 9.. 68 6' -10" 6'- 10' 6'- 10, 72 6' - 5" 6' - 5" TABLES 1 & 3 NOTE: ENTER TABLE WITH NEGATIVE DESIGN LOAD TO DETERMINE MAX. PANEL SPAN (1-max.). POSITIVE LOADS LESS THAN OR EQUAL TO THE NEGATIVE LOAD ARE ACCEPTABLE. FOR DESIGN LOADS BETWEEN TABULATED VALUES, USE NEXT HIGHER LOAD OR LINEAR INTERPOLATION MAY BE USED TO DETERMINE ALLOWABLE SPANS. QT ' S SjTjEM � '?ESiGNEi _ F{ dTLNAW,11E 2EJ1`SLNTOISE!P-.ARP GL RE iR + T'i'1 QIM N!t°k M`T7-Tc'T� LENGTHS AS NOTED. PANEL LENGTHS LESS THAN THOSE NOTED IN TABLE ARE NOT ACCEPTABLE, UNLESS SITE SPECIFIC POROSITY CALCULATIONS ARE PERFORMED BY A PROFESSIONAL ENGINEER. I (DWI��dl 0 Q oa eZ e C� 'kZ 00 ENIt' OF. �R�, adhI ��I oSv-oIl oQ�� ozl � I