HomeMy WebLinkAboutSUBMITTED PAPERSDate: 'G/krJW • I Fee Due:
w
Permit #
1. Location/Site Address:
2. Parcel ID Number:
3. Descr
St. Lucie County Building & Zoning
2300 Virginia Avenue Ft. Pierce, FL 34982-5652
Tel. 772-462-1553
APPLIC
CIO
ON FOR ROOF PERMIT 111161
Office Use
Only
Section
TownshipRange
Ma Pa
Zonin
Land Use
Initials
?)
40
P40W
1(1 S
lZ.y
iption of Project or Work Activity: -Q �p
4. Total Roof Area (square feet): 5. Roof Pitch:
6. Type of Roof: El Fiberglass Shingle Barrel/Tile Ceramic ❑Wood Shake Shingle
❑Tar &Gravel Modified Bitumen ❑Metal
❑Other (specify)
N.O.A - Product Approval required for All Types of Roofing Material
❑ All Commercial Roofing Requires Design by an Engineer or Architect (two Sets)
7. Owner
Name:
Address:
City:
Zip:
t 1 rig
8. Contractor
FL Reg/Cert #:
County Cert#:
State: -1(__- " Business Name:
Phone: �17U('d3q Phone
9. Value of Construction: $
Ivy
Note: Dry -in and Final Inspection Required.
Additional inspection may be required per Product Approval
OWNER'S AFFIDAVIT: I certify that all of the information contained in this applic tion is orrect and that all work will be done
in compliance with all applicable la ons uc ton o ing.
VVA A L,1' 4WLS ` o
PRINT, QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER
7:
STATE OF FLORIDA, COUNTY OF � G t GED BEFORE ME THIS DAY OF
202S BY •) Ontr( ._ `}� ((�DYI HO IS PERSON Y KNOWN TO ME OR WHO HAS PRODUCED
.. . :•s.euunumunuuunnN
AS IDENTIFIC_ IRISHA NEAL MIGLEY
COMM#DD0706197 '-
GNATU E OR RINT N OF T S;R Expires 8I251�4��i
����� Flortda NoteryAsan.. h1C ;
TITLE: NOTARY PUB C COMMISSION NUMBER nrea®..euuu.e.e. 6uu..H
St. Lucie County Roof Permit Application rev.
10,
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-2522
http://stiucieco.gov/ce
Review Comments
PROPERTY INFORMATION
Address: 3805 PROMENADE WAY
City / State / Zip: FORT PIERCE FL 34982
Parcel # : 2433-502-0041-000/6 Jurisdiction: St. Lucie County
Zoning: RS-3 Lot # : 41 Block:
APPLICATION INFORMATION
Permit Number: 0807-0148
Activity Type:
Permit Type: Roof
CONTRACTOR INFORMATION
Contractor Name: TIMOTHY HUTCHINSON
Business Name: ON SHORE ROOFING SPECIALISTS INC
Business Addr: 915 E OCEAN BLVD SUITE E
City / State / Zil STUART, FL 34996
REVIEWS AND COMMENTS
Review Type Status
Plans Examiner Review Incomplete
Page 1
Owner(s):
FRANCOIS A KAIS
Application Type: Over the Counter Permit
Other Activity:
Stories: 1 Automatic Sprinkler System?
Fax Number 772-287-1303
Reviewed By Date Started Date Complete Date Released
Joe Cicio 07/10/2008
07/10/2008 1 Comment CONTRACTOR TO SUBMIT SECTION R4402.14 IN DUPLICATE FOR REVIEW WITH THIS PERMIT [
UNIFORM PERMIT APPLICATION]
07/10/2008' 2 Comment SUBMIT THE RAS 118, 119,.120 SPECS PROPOSED FOR THIS JOB HIGHLIGHTED IN DUPLICATE'
07/10/2008 3 Comment CONTRACTOR TO HIGHLIGHT THE MIAMI-DADE PRODUCT APPROVALS FOR THE HANSON TILE
07/10/2008 4 Comment SUBMIT A LETTER AS TO WHICH ENGINEERING FIRM WILL BE PERFORMING THE UPLIFT
TESTING
07/10/2008 5 Comment SUBMIT THE PRODUCT APPROVAL FOR THE TILE UNDERLAYMENT IN DUPLICATE
07/10/2008 6 Comment COMMENTS MAILED TO OWNER AND CONTRACTOR AS OF THIS DATE
2008-07-1615:24 PINEAPPLE 7722871303» 7724625443
P 1/4
-7�
pzol �y
i
01
V
Jul 16 08101;52p Katherine Clev.. , 561 W39 P.1
Cleary Inspection Services, Inc_
Fax (661) M-8038
Office (661) 682-0114
Cell (561) 722-9881
ly. (� '
ne •�� _
106 Tile Uplift TEST INFORMATION SHEET
roject Name:
roject Address:
ress
Erlephone Number Cell
3tal Square Footage �-bC� No. of Elevations
umber of Stories s _�` Need Ladder & size:
require a 28' ladder Contractor to secure ladder
ermit #
oof Fitch
le Installation Date
ment Method
Attachment NCA:
facturer
we need to contact owner prior to inspectic YES NO
ner Name & Telephone Number
TED COMMUNITY ENTRANCE INSTRUCTIONS
�r
7,
VA,d N49MUL [<SO£6L8ZZLL 31ddV3NId 0%9VLO-800Z
Miami -Made County, Florida
1 - Building Coda Coinpikince Office
Sure 1603
Laboratory Certificate - '''�"''� ~ iaR West Flaslar Sweet
-� �= Miami. Florida 33130.1563
r, (305) 375-2901
Fax (305) 375-2908
lea. = that e&4V %aa/=4W SM4M, %0. 4C44d at 187.5 72, ;Paww", Zags
WW4, V S3460 Cab CELL 17amcq ZaAft8av 4% QadwluG a&g Mime Vale
"ate eAk& &*&4ete aad Paotacal 'USSOI - 94, a&d ea &rti a to ^qawu
TAS 105
TAS 106
TAS 126 (Nuclear method only)
Read & 4 tfm a4oe w&rt ft a' teat aia& Ge AwAe4 au matr d ra %asxri - Dade e4gfftt
TOC44V d04 &M*"OdeO
t4 Aga. A#wOa( M#g=r0 �X ffea &4w4wf:
RN, Sailappan, P.E.
This Cert(ication and Registration Approved: May 11, 2006
This CertWation and Registration Expires : May 11, 2011
t:ertifieation No.: 05-090116
Ja 1), Gascon, P.9. Jerry HernetezChief Senior QualiAss yrance InspectorProduct Control Division Product Conof vision
4e %a" -Dude 6uW4 �c � Glade �aaAr�rtluctce O#see ae-� do W*& to a OOM flue
WSW" �ft Owa - OwA&uce wt 44 wdeda#d xqgapt 4 Pie USSOI - 94.
NACERTMC1LA.BOR.NTMOSIO i.due
WE d
£bt,9Z9VzLL <[ £O£6L8ZZLL . 3lddd3Nld bZ'gl 91-LO-8OOZ
Certified Testing Laboratories
7252 Narcoossee Rd.
Orlando, FL 32822
Contact: William Blakely,
Ramesh Patel, P.E.
Ph 407-384-7744
Fax 407-384-7751
Expiration Date: 01/17/12
CEL Consulting
Division of. Quality Assurance Engineering, Inc.
534 23rd Avenue
Oakland, CA 94606
Contact: Lee Mattis, P.E.
Ph 510-436-7626
Fax 510-434-7719
Expiration Date: 10/14/11
1813 N. Palmway — ®@
Lake Worth, FL 33460
Contact: Katherine I. Cleary
R.N. Sailappan, P.E.
Ph 561-722-9881
Fax 561-582-8039
Expiration Date: 05/12/11
Construction Consulting Laboratory Int'l.
1601 Luna Road
Carrollton, TX 75006
Contact: Kenneth H. Lloyd Jr.,PE
Abdol H. Rezadad, P.E.
Andy Wilson
Ph 972-242-0556
Fax 972-245-6047
Expiration Date: 05/17/11
P:\PRODCNTL\LABS\APPROVED\ApprovedLabs93.doc
Internet mail address: BCCnnmiamidade.gov
TAS201
TAS202
TAS203
TAS 114 App. D
TAS 114 App. J
TAS 125
AAMA 103.3-89 Section 5
ASTM D25 6
ASTM D638
ASTM D790
ASTM E8
ASTM E10
ASTM E23
ASTM E72
ASTM E94
ASTM E164
ASTM E165
ASTM E587
ASTM E709
ASTM E783
ASTM E987
ASTM E1004
ASTM E1105
ASTM E1444
ASTM E1592
AWS D1.1 & AWS D1.2
MIL -STD 6866
International Accreditation Services, Inc.
Certificate of Accreditation TL-173
International Accreditation Services, Inc.
Certificate of Accreditation AA-639
TAS 105
TAS 106
TAS 126 (Nuclear method only)
TAS201
TAS202
TAS203
Homepage: Mtn://www.miamidade.gov/buildingeode
FROM: STEVENS. WOOD, P.E.
FL P.E. LICENSE No. 34398
950 SULTAN DR
PSL, FL 34953
TO: ST. LUCIE COUNTY BUILDING DEPT.
2300 VIRGINIA AVE
FT. PIERCE, FL 34982
AUGUST 16, 2008
SUBJECT: CERTIFICATION FOR RE -ROOF HOT -MOP DRY -IN CONSTRUCTION
REFERENCE: PERMIT No. '.� - D S-d
FIFI KRIS RESIDENCE
3805 PROMENADE WAY
FORT PIERCE, FL 34982
THE PURPOSE OF THIS LETTER IS TO CERTIFY THE HOT -MOP PORTION OF THE DRY -IN
CONSTRUCTION AT THE ABOVE REFERENCED ADDRESS. THE ROOF WAS DRYED-IN TO
PREP FOR TILE INSTALLATION WHICH HAS SINCE BEEN COMPLETED.
BASED ON INSPECTIONS AND DISCUSSIONS WITH THE CONTRACTOR, THE
FOLLOWING FINDINGS WERE MADE:
• THE EXISTING ROOF SLOPE/PITCH IS APPROX 5:12.
• HOT MOP DRY -IN CONSTRUCTION CONSISTED OF:
o 90# ASHPALT ASTM MEMBRANE WAS INSTALLED WITH HOT
ASPHALT TAR/MOP METHOD USING 4" MIN LAP.
o LAPPED JOINTS WERE BACK -NAILED @ 12" CENTERS WITH 14"
CAPS PRIOR TO HOT MOP
BASED ON THE ABOVE FINDINGS, THE RE -ROOF HOT -MOP DRY -IN CONSTRUCTION
IS IN COMPLIANCE WITH THE 2004 FBC (INCLUDING 2005 & 2006 SUPPLEMENTS)
FOR 140 MPH WIND ZONE AND EXPOSURE 'B' CLASSIFICATION.
THEREFORE, THE HOT -MOP DRY -IN CONSTRUCTION IS ACCEPTABLE AS IS.
AUG
�22
?008 fit. �Cb/iC W STEVEN G. WOOD, P.E.
k
�� Coy ra �� FL LICENSE 34398
t a�
FROM: STEVENS. WOOD, P.E. AUGUST 16, 2008
FL P.E. LICENSE No. 34398
950 SULTAN DR
PSL, FL 34953
TO: ST. LUCIE COUNTY BUILDING DEPT.
2300 VIRGINIA AVE
FT. PIERCE, FL 34982
SUBJECT: CERTIFICATION FOR RE -ROOF HOT -MOP DRY -IN CONSTRUCTION
REFERENCE: PERMIT No.�- Oft T �l
FIFI KRIS RESIDENCE
3805 PROMENADE WAY
FORT PIERCE, FL 34982
THE PURPOSE OF THIS LETTER IS TO CERTIFY THE HOT -MOP PORTION OF THE DRY -IN
CONSTRUCTION AT THE ABOVE REFERENCED ADDRESS. THE ROOF WAS DRYED-IN TO
PREP FOR TILE INSTALLATION WHICH HAS SINCE BEEN COMPLETED.
BASED ON INSPECTIONS AND DISCUSSIONS WITH THE CONTRACTOR, THE
FOLLOWING FINDINGS WERE MADE:
• THE EXISTING ROOF SLOPE/PITCH IS APPROX 5:12.
• HOT MOP DRY -IN CONSTRUCTION CONSISTED OF:
o 90# ASHPALT ASTM MEMBRANE WAS INSTALLED WITH HOT
ASPHALT TAR/MOP METHOD USING 4° MIN LAP.
o LAPPED JOINTS WERE BACK -NAILED @ 12" CENTERS WITH 14"
CAPS PRIOR TO HOT MOP
BASED ON THE ABOVE FINDINGS, THE RE -ROOF HOT -MOP DRY -IN CONSTRUCTION
IS IN COMPLIANCE WITH THE 2004 FBC (INCLUDING 2005 & 2006 SUPPLEMENTS)
FOR 140 MPH WIND ZONE AND EXPOSURE W CLASSIFICATION.
THEREFORE, THE HOT -MOP DRY -IN CONSTRUCTION IS ACCEPTABLE AS IS.
STEVEN G. WOOD, P.E.
FL LICENSE 34398
Public Works Department
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982-5652
INSPECTION AFFIDAVIT
RE: Permit # D O% — V %av
/ o
,Iicensed as (n) Contra c r*/Engineer/Architect/
(Please print name a d circle license type) 468 Building Inspector*
* General, Building, Residential, o 0o n Contract r or any individual certified under 468 F.S. to make such an
inspection. All affidavits must inc graphs of each plane of the roof with the permit # or address # clearly
shown marked on the deck for each inspection.
On or about
4-0 �' , I didpersonally inspect the roof
(Date & time)
deck nailin and/or seconddry water barrier work at
(circle one)
1 C-C, .
(Job Site Address)
Based upon that examination I have determined the installation was done according to the
Hurricane Mi igat' n Retrofit Manual (Based on 553.844 F.S.)
`Z
Signature & Sear License #
STATE OF FLORIDA
COUNTY OF ( A9 C jl 1
Sworn to and subscribed befcae me this day of .200
by f I.` 1� 11 . Who(ersonall own or who has produced
s,, •o as identification.. _ <
ruu■■.■■■■■.■■■■.■■.*■unu■ n,�. C,
L QUIGLE
TRISHA NEA%�����' Notary Public, State of Florida o
Comm# 1)130706% a
Signature of Notary:
eu Expires 8/2s/2011 .�
y '
Florida Notary Assn., Inc .
w■■..■.■■.■■■■..,.■.....■■.■.■■■■■■■■ua:
Commission No.: ....(Seal)
cml 9/27/07
EDWIN M. FRY, Jr., CLERK,OF THE CIRCUIT COURT — SAINT LUCIE COUNTY
FILE # 3233519 OR BOOK," �)5 PAGE 2681, Recorded 07/17 �D8 at 01:11 PM
NOTICE OF COMMENCEMENT
TO BE COMPLETED WHEN CONSTRUCTION VAL UE EXCEEDS $2,500,00
PERMIT #: TAX FOLIO H:
STATE OF FLORIDA COUNTY OF MARTIN
THE UNDERSIGNED HEREBY GIVES NOTICE THAT IMPROVEMENT WILL BE MADE TO CERTAIN REAL PROPERTY, AND IN
ACCORDANCE WITH CHAPTER 713, FLORIDA STATUTES, THE FOLLOWING INFORMATION IS PROVIDED IN THIS NOTICE OF
COMMENCEMENT.
PROPERTY
GENERAL DESCRIPTION OF
OWNER NAME:
INTEREST IN PROPERTY: aon P
NAME AND ADDRESS OF FEE SIMPLE TITLE HOLDER (IF OTHER THAN OWNER):
CONTRACTOR:
ADDRE
PHONE
SURETY COMPANY (IF ANY):
ADDRESS:
PHONE NUMBER: _
BOND AMOUNT:
LENDER/MORTGAGE COMPANY:
ADDRESS:
FAX
L—e- —Y
22
PERSONS WITHIN THE STATE OF FLORIDA DESIGN BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAY BE
SERVED AS PROVIDED BY SECTION 713.13 (1) (a ., FLORIDA STATUTES:
NAME:
ADDRESS:
PHONE NUMBER:
FAX NUMBER:
IN ADDITION TO HIMSELF HERSELF, OWNER DESIGNATES OF
TO RECEIVE A COPY OF THE LIENOR'S NOTICE AS PROVIDED IN SECTION 713.13(IXB),
FLORIDA STATUES.
PHONE NUMBER: FAX NUMBER:
EXPIRATION DATE OF NOTICE OF COMMENCEMENT:
(THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED).
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13,
FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
COMTICING WORK OR RECORDING Y91 NOTICE OF COMMENCEMENT.
. 11 ;ts ��o n --.? g( - - -&
9 RE ' 7�6
OF OWNER OR O NIXS AUTHORIZED OFFIC HIECTOR/PARTNE NAG R
agnev
SIGNATORY'S TITLE/OFFICE
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS Ie DAY OF f/ 00'
BY: AS FAR
NAME OF
TYPE
WHOM INSTRUMENT WAS EXECUTED
PERSONALLY KNOWN-9RIkRODUCED IDENTIFICATION �r
F IDET
r v
P O C Z- yP w N NoGot P Farrell Public State of Flodda
My Commission DD636437
Y SI ATUR NOTARY SEAL Va tidy�' V, 1 - !` Expires 03121/2011
V.ND*PENALTIES OF PERJURY, I DECLARE THAT 1 HAVE READ THE FOREGOING AND THAT THE FACTS IN IT ARE
U TO THE BEST OF MY KNOWLEDGE AND BELIEF (SEC ?I�I9'1,5�C"WrfjII"' OTVTES)
aT. Li I C I E COUNTY
( ra of Natural Person Signing bov 10 u E R r I fY T H AT ? H I S I S A �� L
AND uCaR RECT COPY Or THE
HN
Rj
By �c
Co U n'
Oat'n:
�BI r� —a �F 0' E
F
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
oc IF—
�'
W CMQM
a-
o
�
®C3��
ata ®im
CO
W Uj
a- = cu
W Nca
R Cal
SECTION 1525
HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION
Florida Building Code Edition 2004
High -Velocity Hurricane Zone Uniform Permit Application Form.
INSTRUCTION PAGE FILE COP
COMPLETE THE NECESSARY SECTIONS OF
THE UNIFORM ROOFING PERMIT
APPLICATION FORM AND ATTACH THE
REQUIRED DOCUMENTS AS NOTED BELOW:
Roof System
Required Sections of the
Permit Application Form
Attachments Required
See List Below
Low Slope Application
A,B,C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
A,B,C
4,5,6,7
Asphaltic Shingles
A,B,D
1,2,4,5,6,7
Concrete or Clay Tile
A,B,D,E
1,2,3,4,5,6,7
Metal Roofs
A,B,D
1,2,3,4,5,6,7
Wood Shingles and Shakes
A,B,D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED:
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS
128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
FLORIDA BUILDING CODE — BUILDING 15.31
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2004
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section A (General Information)
Master Permit No.
Contractor's Name
r
Job Address
FILE COPY
ROOF CATEGORY
❑ Low Slope ❑ Mechanically Fastened Tile )(Mortar/Adhesive Set Tile
❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes
Shingles
Q9► Prescriptive BUR-RAS 150
/ ROOF TYPE
❑ New Roof Reroofing ❑ Recovering ❑ Repair ❑ Maintenance
ROOF SYSTEM
INFORMATION
Q
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) �( > Total (SF) I
/ 111
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains..
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of
parapets.
15.32 FLORIDA BUILDING CODE — BUILDING
FILE Cop',
OT
FI'LE COPY ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2004
High -Velocity Hurricane Zone Uniform Permit Appli ation Form.
Section C (Low Slope Application) Surfacing'v'(9V
Fill in specific roof assembly components
and identify manufacturer Fastener Spacing for Anchor/Base Sheet Attachment:
(if a component is not used, identify as " NA")
a - Field: " oc @ Lap, # Rows 3 @ �" oc
System Manufacturer:` P
1. . Perimeter: " oc @ Lap, # Rows -F @ ' oc
Product Approval No.: 7i v
orner. oc @ Lap, it Rows @ oc
Design Winne : Pressures, Fro RAS izo or Calculations:
Pmax1/ Pmax2:' Pmax3: 1 `3
Max. Design Pressure, from the recif Product
Approval system:_ _
Deck:
Anchor/Base Sheet & No. of Ply(s): `(.6
An or/Bas Sheet Fasten Bondin Mate ial
- j
Insulation Base Layer:
Base Insulation Size and Thickness:
Base Insulation Fastener/Bonding Materi :
Top Insulation Layer:
Top Insulation Size and Thic ess:
Top Insulation Fastener on in M 'al:
Base Sheet(s)/tener/IB3onding
Ply(s).
Base Sheet F Material:
Ply ZShe(s) & No. of Ply(s):
Ply Fastener/Bonding Material:
Top Ply: l
Top Ply Fastener/Bonding Material:
f� 1
Number of Fasteners Per Insulation Board:
Field PerimDelfnDetalls
Corner
Illustrate Compo is as
Applicable:
Woodblocking, Gutter, Edge Te ' ation, Stripping, Flashing,
Continuous Cleat, Cant Strip, Base shing, Counter -
Flashing, Coping, Etc.
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material Thickness, Fastener
Type, Fastener Spacing or Submit
04 41
Mean
Roof
.1
Height
FLORIDA BUILDING CODE — BUILDING 15.33
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
W
LLM
Florida Building Code Edition 2004
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section E (Tile Calculations)
For Moment based file systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or
equal to the Mr values, for each area of the roof, then the file attachment method is acceptable.
ethod 1 "MomentB sedT Calculat S 127"
(PI: x i =�) Mg. i Mrl-LProduct Approval Mf .
(P2. x ],'� - ) - Mg: = Mr2� 3 Product Approval Mf
(Pg: x X ) - Mg. o = M. _ Product Approval Mf
Method 2 "S' pH ed imow
le Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Belo' i Product An oval Mf 1 -G-
Mr required Moment Resistance*
Mean Roof Height
Roof Slope 1
15,
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
1 32.6
1 34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
*Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals.
For Uplift based tile systems use Method 3. Compared the values forF' with the values forFr.If the Fvalues are greater than or equal to the Fr values,
for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Moment Based Tile Calculations Per RAS 127"
(PI: x L = x w: = ) - W: x cos B = Frl Product Approval F
(P2: x L = x w: = ) - W: x cos 0 = Fr2 Product Approval F
(P,: x L = x w: = ) - W: x cos 0 = F- Product Ancroval F
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
PI or P2 or P3
RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
x
Product Approval
Restoring Moment due to
Gravity
Mg
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
X1
Calculated
Minimum Attachment
Resistance
F
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = lengthProduct
W =width
Approval
All calculations must be submitted to the building official at the time of permit application.
FLORIDA BUILDING CODE - BUILDING 15.35
Sj TION 1524 HIGH -VELD("- '�Y HURRICANE
REQUIR�D OWNERS N... Pagel of2
FILE -COPY
SECTION J1524
HIGH -VELOCITY HURRICANE ZONES —
REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
1524.1.Scope.
As it pertains to. this section, it is the responsibility
with the required roofing permit, and to explain to t
provisions. of Chapter 15. of the Florida Building Cc
requirements and standards of the industry for roof
.following items should be addressed as part of the
contractor. The owner's initial in the designated sp
WnepldAesthetics-workmanship: The works
Velocity Hurricane Zone) are for the purpoE
the wind resistance and water intrusion per
are not a consideration with respect to wort
as color or architectural appearance, that a
Ai addressed as part of the agreement betwe4
the roofing contractor to provide the owner
owner the content of this section. The
Building -govern the minimum
g system installations. Additionally, the
treement betweenthe owner and the
e indicates that the item has been
inship provisions of Chapter 15 (High -
of providing that the roofing system meets
�mance standards. Aesthetics (appearance)
unship provisions. Aesthetic issues such
not part of a zoning code, should be
the owner and the contractor.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck may
have. to be renailed in accordance with the current provisions of Chapter 16_(High-
Velocity Hurricane Zones) of the. (The roof tleck is usually concealed prior to removing
the existing roof system.) I .
® 1. Common roofs: Common roofs are those which have no visible delineation
between neighboring units (i.e., townhouses, condominiums, etc.). In buildings with
common roofs, the roofing contractor and/or owner should notify the occupants of
adjacent units of roofing work to be perform.
AExposed ceilings: Exposed, open beam ceilings are where the underside of the
roof decking can be viewed from below. The owner may wish to maintain the
architectural appearance; therefore, roofing nail penetrations of the underside of the
decking may not be acceptable. The owner provides the option of maintaining this
appearance.
5. Ponding water:. The current roof syst
well and may cause water to pond (accumi
can be an indication of structural distress a
structural engineer. Ponding may shorten t
�t new roofing system. Ponding conditions m;
�t\ 'stem is removed. Ponding conditions shi
16.. Overflow scuppers (wall outlets): It
roof is not overloaded from a buildup of wa
extensions may -block this discharge if over
It may be necessary to install overflow scut
hapter 15 and 16 herein and the Florida I
7. Ventilation: Most roof structures shoe
through the interior of the structural asseml
attic ventilation shall not be reduced. It mai
which can result in extending the service lit
i and/or deck of the building may not drain
te) in low-lying areas of the roof. Ponding
may require the review of'a professional
life expectancy -and performance of the
not be evident until the original roofing
d be corrected.
required that rainwater flow off so that the
Perimeter/edge walls or other roof .
w scuppers (wall outlets) are not provided.
.rs in accordance with the requirements of:
Iding Code, Plumbing.
d have some ability to vent natural airflow
ly (the building. itself). The existing amount of
be beneficial to consider additional venting
of the roof.
'/ecodes.iccsafe.org/icce/gateway
FL/294/318?f=te... 3/20/2008
:11V1N 1:)Z4 HILIH-VbLU, Y HUMUL;Alvh GV1Vrra— KEQUMl I) OWNEKS N... Page 2 of 2
Owner's/Agent's Signature Date Contractor's Signature
%ecodes.iccsafe.org/icce/gateway
18?f=te... 3/20/2008
ROOFING APPLICATION STANDARD (RAS) No. 120
MORTAR AND ADHESIVE SET TILE APPLICATION
1. Scope
This application standard covers the procedures
for installation of mortar or adhesive set roof tile
systems. This standard shall be used in conjunc-
tion with the tile manufacturer's Product Ap-
proval and RAS 127.
2. Definitions
For definitions of terms used in this application
standard, refer to ASTM 1079 and the Florida
Building Code, Building.
NOTE #1: The following table provides the
contractor with the choices
available for underlay systems.
These systems can only be used
on pitches designated in the ta-
ble below:
FILE COPY
Roof Pitch _
Choice of Underlayment
Plastic or Compatible Roof
Cement at Nails Penetrating
Underlayment
Reference
1. ASTM D 226 Type I4
#30 or ASTM D 2626
_ _
2:12 or greater
(#43) inorganic base nailed
to deck, min ASTM D 249
Required
3.01 A
(#90) organic cap sheet se
in Type IV hot asphalt.
2. Any product approved
underlayment system with
a mechanically fastened
base sheet, and cap sheet
per Product Approval
3.01 B, C, or D
set hot, cold, or self
adhered.
FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ
(RAS) 120.1
(RAS) No. 120 u'
This Rooting Application Standard covers flat, low
1. Fasteners shall be in,
a„
and high -profile roof tile, using a minimum 2 in. the
compliance with Section
headlap, or design limited headlap as specified in
1523 of the Florida
tile manufacturer's Product Approval. Installed on
Building Code, Building
I I
minimum 15/32 in. solid decking nailed in compli-
(herein referred to as
,
ance with Chapter 23 (High -Velocity Hurricane
"Approved Fasteners").
Zones) of the Florida Building Code, Building.
a ils shall be mini -
PART I -GENERAL
rnum 12 gage, an-
nular ring shank
nails having not
1.01
less than 20 rings
per inch; heads not
A. Tiles:' 'hall not be installed over
less than 3/K in. in
diameter; and
wet underlayment where moisture
lengths sufficient to
prohibits adhesion of mastic, mor-
penetrate through
tar, or adhesive.
the plywood panel
or wood plank
decking not less
than 3/16 in., or to
PART 11- MATERIALS
penetrate into a 1
in., or greater,
2.01 Fasteners:
thickness of lumber
not less than I in..
Nails shall be hot
A. Tile Fasteners:
dipped; electro or
mechanically gal-
vanized to a thick-
]. All roof file nails or fasten-,
ness sufficient to
ers, except those made of
resist corrosion in
copper, Monel, aluminum,
compliance with
or stainless steel, shall be
Appendix E of
tested for corrosion in com-
TAS 114. All nails
pliance with TAS 114 Ap-
shall have Product
pendix E, Section 2 (ASTM
Approval. All nail
G 85), for salt spray for
cartons or carbon
1000 hours. Tile fasteners
labels shall be la -
used in coastal building
beled to note corn -
zones, as defined in Chapter
pliance with
16 (High -Velocity Hurri-
ion-resis-
cane Zones), Florida Build-
ance requirements.
tance r
I
ing Code, Building shall be
copper, monel, aluminum,
or stainless steel.
(bb) Such fasteners shall
All roof tile fasteners shall be
be applied through
"tin caps" not less
of sufficient length to pene-
than 1518 in. and not
trate a minimum '/, in.
more than 2 in. in
I I through the thickness of the
diameter and of not
deck or batten, whichever is
less than 32 gage
less, or to penetrate into a 1
(O.O10 in.) sheet
I I in., or greater, thickness of
metal. All tin caps
lumber not less than 1 in.
shall have Product
Approval.
B. Underlayment Fasteners:
(RAS) 120.2 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ
1 _
\ (RAS) No. 120
(cc) Prefabricated fas-
B. Cold process modified bitu-
,� tener systems coin-
men roofing mastic - conform -
plying with Section
ing to ASTM D 3019, Type III.
1517.5. Florida
Building Code,
Building may be
C. Asphalt - conforming to
used, (provided they
ASTM D 312, Type IV.
II have Product Ap-
proval).
2.04 Adhesive/Sealant:
2.02 Metal Flashing:
A. Structural bonding adhesive -
conforming to ASTM 3498.
A. Flashing materials shall comply
with the requirements set forth in
2.05 Mortar:
Chapter 15 (High -Velocity Hurri-
cane Zones) of the Florida Build-
ing Code, Building.
A. Materials:
I. Metal accessories for roofs
1.
Roof tile mortar shall ei-
shall be not less than 26
ther be a premixed unit
gage galvanized or stainless
having an Product Ap-
steel, 16 ounce copper,
proval and tested in com- I I
0.025 in. thick aluminum,
pliance with TAS 123 or
lead sheet with a minimum
a job site mix approved
2.5 lb/sf or equivalent non-
by the building official
corrosive lead metal alloys
and in compliance with
or composite materials
manufactured for use as
RAS 113.
roof termination. All com-
B. Mixes:
® posite and nonmetallic
flashing materials shall
have Product Approval.
1. Sand/cement mixes, job
mixed or premixed, shall
2. Metal accessories may be of
meet ASTM C 270 re-.
LU a manufactured, shop fabri-
quirement for Type M
cited or field fabricated
mortar (2.25 to 2.5:1-
type, provided the materials
sand to cement ratio).
ww� and fasteners are in compli-
LLWance with the minimum re-
2. Lightweight aggre-
(�
quirement of this Code and
gate/cement mortar must
shall be installed in compy-
be premixed and bagged.
ance with methods set forth
in RAS 1 11.
2.06 Eave Closure —CHOOSE ONE of
the following: -.
2.03 Asphaltic Adhesive:
IQ A. Prefabricated EPDM synthetic
A. Asphalt plastic roof cement - con-
rubber conforming to ASTM D
forming to ASTM D 4586, type If.
1056.
nonasbestos, nonrunning, heavy
body material composed of as-
phalt and other mineral ingredi-
B. Prefabricated metal eave closure
ents.
m ust contain minimum'/yin. di-
ameter weepholes, spaced not
more than 12 in. apart, flush
with the underlayment.
FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ (RAS) 120.3
(RAS) No. 120
0
C. Prefabricated concrete or clay
chor/base sheet end laps shall
eave closure.
be a minimum of 6 in. and head
laps shall be a minimum of 4
in. Over installed anchor/base
D. Mortar (color optional) on granu-
sheet, apply one layer of min-
lar surface underlayments only.
eral surfaced cap sheet ASTM
D 249 in full 25 lb./sq, ± 15 per-
E. Antiponding drip edge.
"cent mopping of asphalt. As-
phalt shall be applied
uniformly so that felts do not
2.07 thing Material shall conform to
touch felts. End laps shall be a
APA rated sheathing, in compliance
minimum of 6 in.; head laps
with Chapter 23 (High -Velocity Hurri-
shall be a minimum of 3 in. and
cane Zones) of the Florida Building
back nailed 12 in. on center
Code, Building.
with approved nails through
tincaps.
A. B� tens -material to be decay re-
sist.. t species or pressure tre ed
in co liance with AWP -2
or, Bette .
1. Battens hall not be bowed
FIELD TILE CAPS
I—®12'��
or twiste®
LAP TIN CAPS
^°
_—BACHNAILEDTHROUGH
TM CAPS 17 a.c.
2. Vertical batte s shall be a
WENDLAP � ^ WHEAD LAP
minimum of no inal 1 in. x
ANCHORIBASE—
SNEET LAP4 .•/
4 in., horizonta battens
shall be a minimum f nom-�'
inal 1 in. x 2 in.
--B END LAP
PART III - EXECUTION
DRAWING 1-
TYPICAL 30/90 HOT MAP
3.01 Underlayment Applications - CHOOSE
ONE of the following:
NOTE #3: The above system may be up-
graded by .hot mopping an
NOTE #3: Anchor/base sheet shall be a mini-
interply'6f ASTM listed fiber -
mum of two plies in the valleys.
glass or perforated organic felt
Cap -sheets for mortar set systems
to the anchor'sheet before ap-
shall be mineral surfaced. A No.
plying the cap sheet. Asphalt
30 or No. 43 can be used as a
application shall be per above
dry -in prior to installing the
specifications.
underlayment with this system
B. Hot applied Product Approved I
I
A Hot Mop 30/90, Hot Mop 43/1
underlayment system (see
(See Drawing 1). A No. 30 or No
Drawing 1). An anchor/base
43 anchor/base sheet ASTM D
sheet shall be mechanically at-
226, Type 1I, or ASTM D 2626
tached to the wood deck (un-
shall be mechanically attached to
less directed otherwise by
the wood deck with approved fas-
Product Approval) with ap-
teners spaced in a 12 in. grid stag-
proved fasteners spaced in a 12
gered in two rows in the field, and
in. grid staggered in two rows
6 in. on center at the laps. Extend
in the field, and 6 in. on center
anchor/base sheet a minimum of 4
at the laps. Anchor/base sheet
`
in. up vertical surfaces. An
end laps shall be a minimum of
(RAS) 120.4 FLORIDA BUILDING CODE -TEST PROTOCOLS HVHZ
(RAS) No. 120
6 in. and head laps shall be a mini-
underlayment in compliance
mum of 4 in. Over installed an-
with the self -adhered
chor/base sheet, apply one layer
underlayment manufacturers'
of cap sheet in a full 25# /sq. ±15
Approval/ Requirements.
percent mopping of asphalt. As-
phalt shall be applied uniformly
E. Self -Adhered Underlayment
so that felts do not touch felts. End
(single ply). A single ply
laps shall be a minimum of 6 in.;
underlayment system utilizing
head laps shall be a minimum of 3
any Product approved self -ad -
in. and backnailed 12 in. on center
hered underlayment. The roof
through tincaps'
cover is terminated at ap-
proved metal flashings. Apply
C.
Cold applied Product approved
one layer of any self -adhered
underlayment system (see Draw-
underlayment in compliance
ing I). An anchor/base sheet shall
with the underlayment manu-
be mechanically attached to the
facturers' approved/require-
wood deck with approved fasten-
ments.
ers spaced in a 12 in. grid stag-
gered in two rows in the field and
3.02 Drip Edge Metal - CHOOSE ONE of
6 in. on center at the laps or as
the following:
specified in the underlayment
manufacturers Product Approval.
Anchor/base sheet end laps shall
NOTE #5: All exposed planes of drip
be a minimum of 6 in. and head
edge to receive asphalt shall be
laps shall be a minimum of 4 in.
primed with ASTM D 41 As -
Over anchor/base sheet, apply one
phalt primer.
layer of cap sheet in a continuous
layer of cold process adhesive at
the rate of 1.5 gal/sq. or at the rate
ply underlayment systems.
Q
I
if so stated in the Product Ap-
proval. Adhesive shall be applied
1. Drip edge metal shall be
uniformly with a squeegee or
installed overanchor/base
knotted brush so that felts do not
sheet, fastened4 in. on
touch felts. Cap sheet side laps
center with approved 1114
shall be a minimum of 6 in.; head
in. roofing nails or ap-
laps shall be a minimum of 3 in.
proved fasten-ers. All
and backnailed 12 in. on center.
joints shall be lapped a
minimum of 4 in. ensur-
D.
Product Approved Anchor/Base
ing water shedding capa-
S h e e t/ S e If- Adhered
bilities and sealed with
Underlayment system. The roof
plastic roof cement.
®
cover is terminated at approved
metal flashings. Any approved
anchor /base sheet as listed in the
Product Approval shall be me-
chanically attached to the wood
ROOFINGEN LAPSNT,1
BEHEEEHvas
deck with approved fasteners
p p �
ANCHOR/ BASE SHEET 1t
spaced in a 12 in. grid staggered in
two rows in the field and 6 in. on
_
"'� \ \ o
®"
center at the laps or as specified in
@4c SHANK NAILS
the underlayment manufacturers
L4'MErAL
Product Approval. Anchor/base
sheet end laps shall be a minimum
of 6 in. and head laps shall be a
minimum of 4 in. Over anchor
[base sheet, apply one layer of any
Product approved, self -adhered
DRAWING 2
DRIP EDGE INSTALLATION
FLORIDA BUILDING CODE —TEST PROTOCOLS HVHZ (RAS) 120.5
(RAS) No. 120
B. When drip edge metal shall be in-
stalled at eaves and cables over a
two ply underlayment system:
The metal profile shall be placed
in a minimum;/16 in. bead of con-
tinuous ASTM D 4586 plastic
roof cement and fastened 4 in. o.c.
with approved 1 1/4 in. roofing
nails or approved fasteners. All
bonding surfaces shall be fully
primed with ASTM D 41 primer.
All metal joints shall be lapped a
minimum of 4 in. ensuring water
shedding capabilities and sealed
with approved plastic roof ce-
ment. The metal profile and cap
sheet shall be joined with a two
ply application of cotton or fiber-
glass fabric reinforcement, both
set in a full bed of approved plas-
tic roof cement. As an alternate,
the metal may be stripped in with a
6" strip of torch, hot asphalt or
cold adhesive polyester rein-
forced modified bitumen. Joints
shall be feathered with cold adhe-
sive, hot asphalt or a torch to en-
hance water flow across the
"baeklap."
3.03 Valleys - CHOOSE ONE of the follow -
mg•
NOTE #6:
All metal surfaces to receive hot
asphalt shall be primed with
ASTM D 41 asphalt primer.
A.
Preformed or roll metal without
returns 16" wide shall be placed
over the anchor/base sheet in the
valley and shall be fastened with
12 ga. corrosion -resistant roof
nails, or other approved fasteners
of compatible metals near the out-
side edge of the valley metal. All
joints shall be water shedding and
lapped a minimum of 6 in. in a bed
of plastic roof cement. The cap
sheet shall be bonded to the metal
with asphaltic adhesive (see
Drawing 3).
16' VALLEY METAL
W LAP SET IN ---
MASTIC & NAILED
RING SHANK NAILS
f`''i
-SACKNAILED
THROUGH TIN
CAPS
-MIN. 4' LAP
DRAWING 3
TYPICAL VALLEY INSTALLATION
B. Preformed or roll metal with-
out returns 16 in. wide, shall be
installed on top of the cap
sheet, fully embedded in hot
asphalt or plastic roof cement.
All joints shall be water shed-
ding and lapped a minimum of I
6 in. in a bed of plastic roof ce-
ment. Strips of cap sheet, not
less than 8 in. wide shall be
lapped over the metal edge, not
less than 4 in. and sealed with
hot asphalt or plastic roof ce-
ment and membrane. An op-
tional #90 sweat sheet 36 in. I I
wide may be applied prior to
the installation of the cap sheet
and valley metal. (see Drawing
4).
16• VALLEY METAL
MIN. 8' STRIPS
SET IN MASTIC .
NAIL ENDS WITH
RING SHANK NAILS
OPTIONAL SWEAT SHEET
MIN. SLAP •
V' 'NAIL/NDS
r.
DRAWING 4
VALLEY METAL STRIPPED IN
{iiyt'; r
(RAS) 120.6 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ
(RAS) No. 120
3.04 Flashing and Counter Flashings at Wall
Abutments
NOTE #7: In no case shall top of vertical
flashing be less than 2 in. above
tile surface.
A. Two -Ply System - (Choose 1 or 2)
(see Drawings 5, 6 and 7).
l . In. tall minimum 4 in. x 5 in.
metal flush to base of
alls with 4 in. flange on
the anchorlbase sheet and
fasten within 1 in. of outside
I I
edge. Lap joints 4 in. ensur-
ing water shedding capabil-
ities and apply approved
plastic roof cement between
laps. Fasten the vertical and
horizontal flange of metal
within I in. of out side edge
a minimum of 6 in. on cen-
ter. The cap sheet shall be
bonded to the metal with as-
phaltic adhesive.
-ANCHOR/BASESHEET
UP VERTICAL WALL
— CAULKED BEAD
APPROVED FASTENERS
® S' o.a
-- MIN. 4' LAP SET IN MASTIC
-- APPROVEDADHESWE '
--------- COUNTER FLASHING
-- -RING SHANK NAILS
® S' o.a
-�— CAP SHEET
DRAWING 5
WALL FLASHING DETAIL
(COUNTER FLASHING WITH CAULKED BEAD)
FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ
".EMSRAI
SET IN MAS'
NOR I BASE SHEET
VERTICAL WALL
AL WA L FLASHING
APPROVED FASTENERS
or..
MIN. a' LAP SET IN MMITIC
APPROVEOADHESI'
STUCCO
STUCCO STOP
CDUNTER FLASHING
RING SHANK NAILS
4 a...
CAPSHEET
DRAWING 6
WALL FLASHING DETAIL
(STUCCO STOP DETAIL)
ANCHOR/BASE SHEET
UP VERTICAL WALL
j --APPROVED FASTNERS
—MIN. 4' LAP SET IN MASTIC
DRAWING 7
WALL FLASHING DETAIL
(WALL FLASHING OVER CAP SHEET)
AILS
2. Install minimum 4 in. x 5
in. "L" metal on the top
ply and fastened 6 in. on
center with 12 ga. corro-
sion resistant roof nails,
or other approved fas-
teners compatible
metals within 1 in. of
the
outside edge shall
metal. All joints shall be
lapped a minimum of 4
in. ensuring water shed-
ding capabilities and ap-
ply plastic cement
(RAS) 120.7
(RAS) No. 120
between laps. Cap sheet
shall be joined with a bed of
plastic roof cement and a 4
in. strip of asphalt saturated
cotton or fiberglass fabric.
The fabric shall be fully em-
bedded in the plastic roof-
ing cement.
3.06 Pipes, Stacks, Vents, etc. (see Draw-
ings 8 & 9).
.-FLASHING SHEET TO
3. Seal along top edge within 1 EXTEND 4' BEYOND FLANGE
in. of vertical flange, cover- LEAD STACK f_ ;Y
APPROVED MASTIC
ing all fastener penetrations
with approved plastic roof FASTENERS
cement and membrane. "
4. When installing optional
counter flashing, lap top
flange of base flashing min-
imum 3 in. Fasten metal
within 1 in. of the outside
edge a minimum of 6 in. on
center or set into reglets (se-
cured properly) and thor-
oughly caulk. Lap joints
minimum 4 in. ensuring
water shedding capabilities
and apply approved plastic
roof cement/sealant be-
tween laps.
LEAD STACK --
3.05 Standard Curb Mounted Skylights,
Chimneys, etc. (see Section 3.04 above).
A. Curbs s 11 be a minimum 2 in. x 6
in., and a inimum 2 in. above up-
permost add cent finished tile sur-
face.
B. Follow instructio s in 3.04 A o
in this System.
NOTE #8: For self -curbing or refabricated
skylights, installatio shall meet
Section 3.04B above a skylight
manufacturer''s Prod ct Ap-
proval. For turbines an other
Product approved accessod re-
fer to the accessories manut -
turer's Product Approval^
DRAWING 8
NPPROVED MASTIC
FASTENERS
DRAWING 9
A. Apply approved plastic roof
cement around base of protru-
sion and on the bottom side of
metal flanges sealing unit base
flashing to the underlayment.
B. ail all sides within 1 in. of
utside edge of base flashing 6
in. on center. Make certain
base is flush to deck.
(RAS) 120.8 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ
(RAS) No. 120
sc,
NOTE #9: If pipes, vents and/or stacks are in-
over fascia/starter
., ,.
stalled after finished cap sheet has
strip. Fasten top
been applied, follow instructions
edge of flange
in 3.06 A & B. Cap sheet and
onto roof and fas-
metal flange shall be stripped in
ten cave edge to
with at least the same cap sheet
raised fascia detail
felt in use on this system. Strip-
with approved fas-
ping must extend at least 4 in. be-
teners 4 in. on cen-
yond flange in all directions. For
ter.
turbines and other Product ap-
proved accessories refer to the
Product Approval.
4. Prefabricated concrete
or clay cave closure -
fastened per manu-
3.07 Tile Installation:
facturer's specifica-
tions, such fasteners to
A. Eave treatment -CHOOSE ONE
be approved and sealed
with plastic roof cement.
of the following:
1. Prefabricated EPDM syn-
NOTE #10: All fastener penetrations shall
be sealed. Mortar cave closures
thetic rubber -Install clo-
shall only be used with granu-
sure strip along cave. Fasten
lar surface underlayments.
each piece at 12 in. on
center (see Drawing 10).
6. Mortar Application - Install
2. Metal Eave Closure - Install
mortar to elevate cave edge.
closure strip along cave.
r'.
Fasten a minimum 12 in. on
(aa) Apply mortar
°
center. If metal is inclusive
along the cave
of drip edge, fasten 4 in.
edge, applying
on.center (see Drawing 11).
enough mortar to
elevate the cave
end of the tile to be
3. Raised Fascia/Wood Starter
on profile with the
Strip when using a s/4 in.
remaining rooftile.
raised fascia, a nominal 2 in.
®
x 2 in. wood starter strip
must be installed behind
CJ
fascia.
(bb) oint and smooth
finish flush to cave
(aa) Install fascia board ap-
line.
LU
proximately 1'/2 in.
above roof deck or a
ftaftj(cc)
nominal 2 in. x 2 in.
Applv minimum
�/8
wood starter strip at
in. weep hole
roof edge (see Draw-
flush with the roof
ing 12).
underlayment at
spacing of not less
than one weephole
(bb) Install 8 in. tapered
per tile.
cant strip at cave be-
hind fascia and/or
starter strip to support
NOTE #1 1: Tile shall be attached to resist
metal flashing. In-
the design pressures for the
stall a minimum 8 in.
building. See Chapter 16
wide antiponding
(High -Velocity Hurricane
metal flashing to en-
Zones) of the Florida Building
sure positive drainage
Code, Building and RAS 127.
FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) 120.9
(RAS) No. 120 r t
See tile manufacturer's Product
Approval for attachment resis-
tance values, which must exceed
the required calculated design
pressures of the structure.
FASTENER
SEAL PENETRATION
CAP SHEET
UNDERLAYMENT
MORTAR
OPTIONAL CAST
ANTI-PONDING
METAL
TILE
WOOD DECK
OPTIONAL WOOD STRIP
FASCIA BOARD
DRAWING 10
EAVE TILE DETAIL
(EPDM EAVE ENCLOSURE)
FASTENER
SEAL PENETRATION
CAP SHEET
UNDERLAYMENT
MORTAR
METAL ENCLOSURE
i..
OPTIONAL WOOD STRIP
DRAWING 11
EAVE TILE DETAIL "
(METAL EAVE ENCLOSURE)
TILE
60
FASTENER
BATTEN TILE
CAP SHEET
UNDERLAYMENT
MORTAR
PREFABRICATED EPDM
WOOD DECK
Ve
NAIL & SEAL FASCIA BOARD
PENETRATION
OPTIONAL WOOD STRIP
DRAWING 12
EAVE TILE DETAIL
(ANTIPONDING METAL)
A. Mortar/Adhesive Application:
Low, High and Flat Profile Tile
(see Drawings 13).
1. Set tile in a bed of ap-
proved mortar/adhesive
Apply 10 in. minimum
f
length trowel of mortal
or required amount of
adhesive vertically un-
der pan. For flat tile
place mortar/adhesive
vertically adjacent to the
I
overlock of the tile being
installed. Do not apply
mortar under headlug of
tile, or onto the
underlock of adjacent
tile. (Unless otherwise
specified in adhesive's
manufacturers Product
Approval)
2. Use half starter/finisher
tile when provided or
cut/break tile for proper
staggering of tile courses
when using the stag-
gered/cross bond
method of installation.
(RAS) 120.10 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ
(RAS) No. 120
FILE COPY
.��
/l
MIN. 3/8' WEEPHOLE
(ONE PER TILE)
�--ELEVATE FIRSTTILE TO MATCH PROFILE
B. Two -Piece Barrel Tile Mortar
r'TROWEL OR or Adhesive Application (see
RIADHESIVE PER Drawing # 14):
CT APPROVAL
/(IJ Apply 10 in. mason's
trowel of mortar or re-
quired amount of adhe-
ONAILSPER TILE slve in accordance with
the tile system Product
Approval vertically over
chalk line and under cen-
ter of each pan with nar
row end facing down
roof.
2. Place bed of mortar or
required amount of ad-
hesive in accordance
MORTAR SET TILE
with the tile system
Product Approval along
inside edges of pans and
3. Set file in stepped course
set covers with wide end
fashion or in a horizontal
facing down roof.
and/or vertical fashion
when utilizing straight
bond method.
3. Point mortat to form ac-
ceptable straight -edge
Lay succeeding course of
finish ensuring contact
along edges. Cosmetic
field tile in same manner.
use of mortar is accept-
able for use with adhe-
5. Cut break field tile to form
sive set tiles.
straight edge at center of
hip/ridge.
4. Lay succeeding courses
of field tile in same man -
NOTE #12: Mortar or adhesive set the shall be
ner. Bed of mortar or ad -
applied at inclines of 2:12 and
hesive should make
greater. For pitches of 6 in.: 12 in.
contact with head of
up to and including 7 in.: 12 in.
lower course of file and
nail every third tile in every fifth
underside of file being
course in addition to mortar or ad-
set.
hesive. For pitches above 7 in.: 12
in. nail every tile in addition to
5. Cut/break field tile to
mortar or adhesive. Apply ap-
form straight edge at
proved flashing cement to seal all
center of hip/ridge.
nail penetrations. Fastening re-
quirements at slope of 7:12 or less
for Two -Piece Barrel application
3.08 Valleys - CHOOSE ONE of the fol-
applies to pan tiles only. No mor-
lowing:
tar or adhesive products shall be
applied in a manner which pre-
NOTE #13: It may be necessary to remove
vents drainage of water under
the lugs from the field tile at
tiles,
walls and valley flashings for
proper positioning of cut field
tiles.
FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) 120.11
(RAS) No. 120
CAP SHEET APPROVED MORTAR/ADHESIVE
JX MORTAR J ADHESNE PAD
MIN. W WEEPHOLES
DRAWING 14
BARREL TILE INSTALLATION
A. Standard Roll Valley
Closed valley - Miter tile to
meet at center of valley.
2. Open Valley - Chalk a line a
minimum 2 in. on both sides
of the valley center. Place
bed of mortar along outside
edge of chalk lines. Miter
tile to form straight border
and point to match tile sur-
face.
B. Preformed Metal Without Re-
turns
1. Closed valley - Miter tile to
form straight border on ei-
ther side of water diverter.
2. Open Valley - Miter tile to
form straight border on ei-
ther side of two water di-
verters (see Drawing 15).
3.09 Hip Starter - CHOOSE ONE of the fol-
lowing:
A. Prefabricated hip starter.
DRAWING 15
NAIL -ON VALLEY SYSTEM
VALLEY METAL OVER TILE
Miter tile as hip starter to
match eave lines.
B. Use standard hip tiles as
starter.
3.10 Hip and Ridge Installation - (`
CHOOSE ONE of the following:
A. Set hip and ridge tile in a con-
tinuous bed of mortar, lapping
tile a minimum 2 in. Ensure
bed of mortar does not pro-
trude in center of hip or ridge
junction. Approximately 1 in.
of field tile shall extend be-
yond bed of mortar.
OR
B. Mechanically fasten hip; and
ridge tiles to nailer board shall
be optional on roof slopes of
2:12 to 7:12, and shall be re-
quired on roof slope greater
than 7:12.
1. Wood nailers shall be re-
quired and attached in
compliance with Chap-
ter 16 (High -Velocity
Hurricane Zones) of the
Florida Building Code,
Building. (see Drawing
(RAS) 120.12 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ
Y
/
(RAS) No. 120
16 - Details 1, 2, 3 and 4 are
also accepted methods of
installing Hip and Ridge
Nailer Boards).
2. Wood nailer boards shall be
secured with galvanized steel
straps of a minimum thick-
ness of I/8 in. by 1 '14 in. wide.
The galvanizedsteel straps
shall be installed at a maxi-
mum spacing of 12 in. o.c.
along the length of the ridge
nailer boards. Steel straps
shall be bent to fit over the
ridge nailer boards, and shall
be secured to the sheathing
with a minimum of six #648
corrosion resistant screws
per strap, at a maximum
spacing of 4 in. o.c.
HIP OR RIDGE TILE
f 2x6 OR 2x8 HIP OR RIDGE
_ NAILER PRESSURE TREATED
1/8'x 1-1/4' GALV. METAL STRAP BENT
TO FIT SPACED AT 12' CENTER TO
CENTER
ROOF FRAMING -
�,
PLYWOOD ROOF SHEATHING
ROOF UNDERLAYMENT -- -
BARREL OR FLAT TILE -
BATTENS (AS REQ'D) -- - —
HIP OR RIDGE TILE
NAILING DETAIL
DRAWING 16
DETAIL 1
MINIMUM 212 INCH 20 GAGE x 1' STEEL STRAPS
LUMBER IN ACCORDANCE WITH SPACED W o.o. FASTENED IN
RAS 120 SECTION 207(A) ACCORDANCE WITH RAS 120
SECTION 3.10(B)(2)
DETAIL 2
MINIMUM 2x21NCH- - WOOD NAILER SET IS A
LUMBER IN ACCORDANCE WITH CONTINUOUS BED OF APPROVED
RAS 120 SECTION 2.07(A) ADHESIVE
DETAIL 3
26 GAGE G-90
PREFORMED METAL CHANNEL
FASTENED 6' o.c. WITH
APPROVED ROOFING NAILS
DETAIL4 NAIL TILE IN ACCORDANCE
WITH PRODUCTAPPROVAL
2.6 42 PT BLOCKING
4ti 1 12N 0'-8' 18 GAGE
(VARY DEPTH OF BLOCKING TO
HOT DIP DAM STEEL PLATE
ACCOMMODATE PITCH OF ROOF)
SET IN ROOFING CEMENT.
FASTEN PLATE WITH 248 .1 1?
ROOF TILE
GALV PH SCREWS INTO PLYWOOD
DECK 8 2-48 x 1 1M' GALV PH
SCREWS INTO aG. PROVIDE @ 24' o.c.
12
14
ON EACH S1DE OF BLOCKING
(STAGGER SPACING) 1
/
ROOFTRUSS
FILE COPY
FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ
(RAS) 120.13
(RAS) No. 120
.o
xaeww.vawNma,ous Pro— � ' � ,,rt:
sP e�neNs oPnoNri (Pnawtce '. '-
1I! •, ,?O.LLV. PN bOXflY9VAl11
OPTION. P0.W®E]JB � 1' O.V.V. PN
SCOEWS WITHOUT OPTION)
.-
Mn-DETAIL 5
SHEET PLATE DETAIL
3.11 Rake/Gable - CHOOSE ONE of the fol
lowing:
A. Rake/Gable Tile:
1.
Install first rake tile the ex-
posed length of first course
of field tile with factory fin-
ish of rake tile towards the
eave.
�Z. J
Fasten each rake tile with a.
minimum of two lOD nails
of sufficient length to pene-
trate the framing a minimum
of/q in. '
3.
Abut each succeeding rake
the to the nose of the field
tile above and maintain a
constant headlap.
B. Mortar
Finish:
1.
Place mortar bed along roof
edge.
2.
Point smooth to a straight
edge finish.
3.12 Wall Abutments
A. Cut tile to fit approximately'/�
in. to base of walls. Fill void
with mortar and point to finish.
3.13 Plumbing Stacks
A. Cut tiles to fit close to plumb-
ing stack. Fill void with mortar
and point to finish.
(RAS) 120.14 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ
r t,
2W
MIAMIDADE
BUELDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROI, DIVISION
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
SUITE 1603
FIL M A 33130-1563
3 ) 75 PVF(305 ) 375-2908
NOTICE OF ACCEPTANCE (NOA)
Hanson Roof Tile
1340 SW 34`h Ave
Deerfield Beach, FL 33442
Scopl,
This NOA is being issued under the applicable rules and regulations governing the use of construction
-he documentation submitted has been reviewed by Miami -Dade County Product Control
Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County
and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within
their iiisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade
Couri:y Product Control Division that this product or material fails to meet the requirements of the
cpy_ _ic; :; e wilding code.
This product's approved as described herein, and has been designed to comply with the Florida Building
Code including the high Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Hanson Hacienda Double Roll Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein
R+ 1NE•`YAL of this NOA shall be considered after a renewal application has been filed and there has
beFai no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, ands or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
thus NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
AD'VERTISEN ENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INS-1 r'TION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
t•�rs and shall be av; ilable for inspection at the job site at the request of the Building Official.
1. his `OA consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
MIAMI•i]ADE CAUfVTY
NOA No.: 08-0204.07
Expiration Date: 04/03/13
Approval Date: 04/03/08
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tile
Material: Concrete
1. SCOPE
This renews a roofing system using Hanson Hacienda Roof Tile, as manufactured by
Hanson Roof Tile in Sanderson, Florida and as described in Section 2 of this Notice of
Acceptance. For the locations where the pressure requirements, do not exceed the values
.istec in sew'_icn 4 ha 'n. The attachment calculations shall be done as a moment based
system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Ah lu icartt Dimensions Specifications Description
Length: 17'/4" Low profile, interlocking, extruded concrete
Hanson "Hacienda" Width: 13" TAS 112 roof tile equipped with two nail hole and
'/i" fnictc double roll ribs. For direct deck or battened
nail -on, mortar or adhesive set applications.
Length: varies Accessory trim, concrete roof pieces for use
Trim Pieces Width: varies TAS 112 at hips, rakes, ridges and valley terminations.
Varying thickness Manufactured for each tile profile.
2.1 COMPONENTS OR PRODUCTS MANUFACTURED BY OTHERS
Product Dizrie ss,ons
Vertical
Wood Battens Min. 1"x 4"
,-Iorizoritfii
Min. I"x 4" for use
with vertical battens
or
Min.:" x 2" for use
atone
Tile I``�.i's
Kn. I Cc'x 3"
Test Product
Specifications Description Manufacturer
Wood Preservers Salt pressure treated Generic
Institute LP — 2 or decay resistant (With current NOA)
lumber battens
TAS114 Corrosion resistant
Appendix E screw or smooth Generic
shank nails (With current NOA)
NOA No.: 08-0204.07
Expiration Date: 04/03/13
Approval Date: 04/03/08
Page 2 of 7
i n
COPY
Test Product
'Product Dimemions Specifications Description Manufacturer
. #8x 21/2" long �. Corrosion resistant,
Tile Screws 0.335" head dia. TAS 114 coated, square drive, Generic
0.131" shank dia. Appendix E galvanized, coarse (With current NOA)
0.175" screw thread thread wood screws
dia.
Clips Corrosion resistant
Hurricane Clip & Min. 1/z" width , TAS 114 clips with corrosion Generic.
Fasteners Min. 0.060" thick/Appendix E resistant nails. (With current NOA)
Clip Fasteners
Niin. &: x 1 1/a"
2.2 EVIDENCE SUBMITb"'ED
Test Test Identifier
Redland Technologies 7161-03
Professional Service
Industries, Inc.
The Center for Applied
Engineering, Inc.
Celo:e:: Corporation
TestingServices
Walker Engineering, Inc.
IBA Consultants, Inc.
7161-03
7161-03
P0402
P0631-01
Letter Dated Aug. 1, 1994
224-47099
94-060B
94-084
25-7094-1
25-7094-7
25-7094-4
Project No. 307025
Test #MDC-76
25-7183-1
25-7183-2
25-7214-2
25-7214-6
528454-2-1
5?.0109-2
Calculations
2301-264
Test Name/Report
PA 102
PA 102(A)
PA 108
Withdrawal Resistance Testing of
screw vs. smooth shank nails
PA 108
PA 108
PA 112
PA 101
PA 101
PA 102
PA 102
PA 102
PA 100
PA 102
PA 102
PA 102
PA 102
PA 101
Aerodynamic Multiplier
TAS 112
Date
Dec. 1991
Dec. 1991
Dec. 1991
Sept. 1993
July 1994
Aug. 1994
Sept. 1994
March, 1994
May 1994
Oct. 1994
Oct. 1994
Oct. 1994
Oct. 1994
Feb. 1995
Feb. 1995
March, 1995
March, 1995
Sep.1998
Dec. 1998
March 1999
01/08/08
NOA No.: 08-0204.07
r Expiration Date: 04/03/13
MWhIFDADE COUc.�TY Approval Date: 04/03/08
a z° i� Page 3 of 7
3. LIMITATIONS
3.1 Fire classification is not
-21or�mortar otlhes vi e
q!RM--LQ101 a� Ve uiii
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to
perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be
submitted to the Building Code Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof
slope unless stated otherwise by the underlayment material manufacturers published
literature.
D.6 Phis acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with applicable building code.
4. U-1STALLATION
4.1 Hanson `Haci.f!nda' Roof Tile and its components shall be installed in strict compliance with
Roofing App'ic.ation Standard RAS 118, 119, & 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile profiles
Weight-W (Ibf)
Length-1(ft)
Width-w (ft)
Ha::eson Hacienda Tile
10.1
1.41
1.08
Table 2: Aerod namic Multipliers - A ft
-- Tile
Profile
A (ft)
Batten Application
A (ft)
Direct Deck Application
_
Hanson Hacienda Tile
0.267
0.289
Table 3: Restoring Moments due to Gravi - M. ft-Ib
Tile 3"• 12"
411• 12"
5"• 12"
6"• 12"
711• 12" or
Profile
greater
Hansor: Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Hader-oa Tile
Deck
Deck
Deck
Deck
Deck
5.92
6.80
5.82
6.69
5.70
6.55
5.56
6.39
5.41
6.22
NOA No.: 08-0204.07
Expiration Date: 04/03/13
Approval Date: 04/03/08
Page 4 of 7
Table 3: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf)
L---_
-_ For Nall -On Systems
T"Pe jFastener Type Direct Deck Direct Deck Battens
Profile (Min 15/32" plywood) (Min. 19/32" plywood)
Hanson
2-10d Ring Shank Nails
27.8
37.4
28.8
Hacienda Tile
1-10d Smooth or Screw
8.8
11.8
4.1
Shank Nail
r'
2-10d Smooth or Screw
Shank Nails
16.4 �/
21.9
7.1
1 98 Screw
r26.8
25.8
22.9
2 48 Screw
/ 47.1
47.1
49.1
1-10d Smooth or Screw
/ 24.3
24.3
24.2
Shank Nail Field Clipy
j�1.•10d
Smooth or crew
Shank Nail (Save Clip)
19.0
19.0
22.1
2-10d Smooth or Screw
7ha kltiails (Field Cli
35:5
35.5
34.8
Smooth or ^crew
an Na. s are Cli
31.9
31.9
32.2
2-10d rTr � Sha_,i,: Nails
43.0 67.5
50.9
j 1 Installation with a 4" tiie headlap and fasteners are located a min. of 2%2" from head of tile.
''able 4: Attachment Resistance Expressed as a Moment Mf (ft-Ibf)
For Two Patty Adhesive Set Systems
Tile The Application
Minimum Attachment
_ Profile -
Resistance
Hanson Hacierza Tile Adhesive
26.1
2 See manufactures cc.rnpurlant approval for installation requirements.
3 Flexible Products Company Tiip6cnd Average weight per patty 11.4 grams.
Pol)oar.L Product, lrr:. ;Avara ia r.ei ht er a 8 rams.
FILE -COPY
NOA No.: 08-0204.07
Expiration Date: 04/03/13
Approval Date: 04/03/08
Page 5 of 7
IN
Table 4A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
_ For Single Patty Adhesive Set Systems
Tile Application
Minimum Attachment
_ _ Prof;le
Resistance
Polyfoarn Pol ProTM
86.61
Hanson Hacienda Tile
Polyfoarn Pol ProTM
45.5
4 Large paddy placerneni—of 54 rams of Pol Pro'rm.
5 Medium paddy placement or 24 rams of Pol ProT"'
Table 413: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
For Mortar Set Systems
Tile Tile Attachment
Prorile
Hanson Flaci;mcla Ti
Mortar
$. LABELING
Ail 'Ziles sha:-bear 11s ,,,priat or identifiable marking of the manufacturer's name or logo
(See Detail Below), or following statement: "Miami -Dade County Product Control Approved".
sJ31DVH
HA:NSON HACIENDA ROOF TILE
T"T �.;" UF? -ATION MARK (LOCATED ON UNDERSIDE OF TILE)
6. ,UIIL}= NG PE7 V F: REQL'IR.EWNTS
b,1 .�ppiii auon for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.i A nw other documents required by the Building Official or applicable
.. . ~ g code in order to properly evaluate the installation of this
system.
FILE COPY NOA No.: 08-0204.07
"MCOUEPT7171111,
Expiration Date: 04/03/13
M"I.
Approval Date: 04/03/08
Page 6 of 7
PROFILE DRAWINGS
HANSOM HACIENDA CONCRETE ROOF TILE
V A Q 9r WFV T-D Y 7 di -c V., 0
UNDI
RLOCK
END.O.FITHIS.-ACCEPTANCE
FILE COPY
NOA No.: 08-0204.07
ffimlffm,w�, Dip Expiration Date: 04103/13
Approval Date: 04/03/08
Page 7 of 7
44,
l
t�4 I A M FDAD
BUILDING CODE COMPLIANCE OFFICE (BCCU)
PRODUCT CONTROL DWISION
1iIAMI-DADE COUNTY, FLORIDA
ME:TRO•DADii FLAGLER BUILD)\G
140 WEST FLAGLER STREET. SUITF. 1003
MIAMI, FLORIDA 33130-1303
(305) �75-2901 FAX (305) 375-2903
NOTICE OF ACCEPTANCE (NOA) _
Bermuda Roof Co., Inc.
1499 W. Palmetto Park Road, Suite 169
Boca Raton, FL 33486
SCOPE:
This NOA is tieing issued under the applicable rules and regulations govelping the use of construction
materials. Tho documentation submitted has been reviewed by Miami -Dade County Product Control
Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and
other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid alter the expiration date stated below. The Miami -Dade County Product
Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miatni Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense ol'such testing
and the MU may immediately revoke, modify, or suspend the use of such product or material within their
jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Nlianii-Dade
County Product Control Division that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Binh Velocity
Hurricane Zone of the Florida Building Code.
DESCRIPTION: Lightweight Roof Tile'Mortar
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL!. of this NOA shall be considered after a renewal application has been tiled and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or i f there has been a revision or
change in the materials, use, and/or manufacture of the product or process. (Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this
NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISE&LENT: The NOA number preceded by the words Mianii-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available 11or inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 01-0130.09 and consists of pages 1 through 6.
The submitted documentation was reviewed by Jor e L. \echo.
�"^��T NOA No.: 06-0329.Oi
Expiration Date: 09/20/11
R_. - approval Date: 07/20/06
Page 1 of 6
ROOFING CON'IPONEN'r APPROVAL: FILE Co
Category. Roofing PY
Sub-C:atcbory. Roof Tile Adhesives
Material: Cement
Deck '!'vue: Wood
Maximum Design Pressure N/A
SCOPE:
This renews "File -rite" Roof 'file Mortar, as manufactured by Bernntda Roof Company, Inc. as
described in this Notice of Acceptance, and designed to comply with the High Velocity llurricane
Lone of the Florida Building Code.
PRODUCT DESCRIPTION:
Manufactured by_Applicant DProduct
imensions Description
Premixed prebagged roof tile mortar for used with
`Tt7eTite"TtoofTieaF�ortar> N/A approved roof tile in accordance with RAS 120
LIMITATIONS:
I. fire classification is not part of this acceptance.
2. Field uplift. testing shall be perfomied, in compliance with the test procedure set forth in RAS
106. Testing shall be perfornied not prior to 30 days after installation.
3. "Tile -Tito" Roof Tile Mortar shall he placed in accordance with the 'Placcment Details' provided
herein. Bach generic the profile requires a specific placement. (sec placement Deiail listed
herein).
4. "Tile -rite' Roof Tile N-lortar shall be applied in accordance with Bermuda Roof Specifications.
i. Tile must be applied within .i minutes of the application of "Tile -rite' Roof Tile ]Mortar.
6. Refer to RAS 120, for penetrations and terminations, as well as the Tlacement Dctails' herein.
7. Refer to Tilc manufacturer's Product Control Notice ofAccep►ance for system approvals.
INSTALLATION:
I, "file-Tite Roof 'file Mortar and its components shall be installed in strict compliance with RAS
120.
2. Placement Details
Adhesive Placement: GENERIC PLACEMENT
PROFILE: DETAIL. #
Two piece Barrel A
Spanish & Mission B
Low Profile Roll C
Flat p
I,AB EILING:
All bags shall be labeled in accordance, with the Standard Conditions herein.
_ ' NOA No.: 06-0329.U5
Expiration Date: 09/20/11
G + Approval Date: U720i06
Page 2 of 6
FILE COPY
BUILDING PERMIT REQUIREMENTS:
Any documents required by the Building Official or applicable building code in order
to properly
evaluate file installation of' this System.
EVIDENCES SUBMITTED:
'Pest Agency "Pest Identifier
Test Name/Report
Date
Center for Applied #94-084
TAS 101
04/08/94
Engineering, Inc.
Florida Testing and #450225
ASTNI C9
05/10/94
Engineering, Inc.
Type NI
PRlAsphalt 'Iechnoloeies BRCI-001-02-01
TAS 123,?AS I01
03/14/06
PLACEMEN'I' DETAIL "A"
TILE & MORTAR PLACEMENT - BARREL TILE - 2 PC.
PAN
h10RT.Alt Bl
FOR COIVEF
FASCIA BOARD
ON EDGE
REQUIRED
200F PITCHFS)
T P:1N HERE
rDl'rIONAL
MQUIRED BY CODE)
NAIL COVER HERE
(\M71F_N REQUIRED)
NY1iEE1'110LF//
POIYI'-UP ::]!91K
METAL EA VE DRIP
moit,r.AR BED
NOA No.: 06-0329.05
Expiration Date: 09/20/11
n Approval Date: 07/20/06
Page 3 of 6
n / �
FASCIA BOARD
PLACEMENT DETAIL,FILE
90 # iyIINERAL SURI+ACE
ROOFING FELT
10" MASON TROWEL
FULL OF MORTAR
NAILTHROUGH PLASTIC
ROOF CEMENT (WIZEN
ADDITIONAL NAILING IS
REQUIRED BY CODE
BARGE BOARD
' ,NOA No.: 06-0329.05
y Expiration Date: 09/20/11
Approval Date: 07/20/06
` Page 4 of 6
r
� � 1
PLACEMENT DETAIL " ."
COPY
90 # iiMINER L SURFACE
ROOFING FELT
NAIL. THROUGH PLASTIC
ROOF CEMENT (WHEN
10" MASONTROWEL ADDITIONAL, NAILING IS
FULL OF -MORTAR J I REQUIRED BY CODE
1
I
In
/ O
SECURE WITH CORROSION
FASCIA
12ESISTANCE NAILS
/
BOARD BARGE BOARD
1d'ILEI;PIIOL,E �
POINT -UP WITH COLORED
VIORTAR TO KLATCH TILE,
(EPON) PRE-FARRICATEI SURFACE
CLOSURE NAILED'rIIROUGH ROLLED RAKE TILE
PLASTIC ROOF CEMENT OR (SPANISH 'IS" CUTS)
INTO APPROVED ADHESIVE SURFACE
NOA No.: 06-0329.05
Expiration Date: 09/20/11
4 Approval Date: 07/20/06
Page 5 of 6
PLACEMEV7' DETAIL "®"
TOTE: MORTAR SHALL NOT REACH
INTO THE HEAD OF TILE, IN PREVIOUS
COURSE OR INTO UNDERLOCK OF
ADJACENT "TILE.
10" MASON TROWEL
FULL OF MORTAR
ILEADLAP
�IETA-1. EAVE DRIP
FASCIA BOA
THICKBUT
TILE.
I . 1'IIE BEAD OF ONE TILE
2. THE UNDERLOCK SIDE OF
I A SECOND TILE
3. THE UNDERSIDE OF THE
PILE BEING SET
NAIL, IIERE THROUGH
1PLASTIC ROOF CENIF.NT
(WHEN REQUIRED
BY CODE)
�� •t t
we S
END OF THIS ACCEPTANCE
FILE COPY
NOA No.: 06-0329.05
Expiration Date: 09/20/11
` Approval Date: 07/20/06
Page 6 of 6
i
MIAMI-DILE
ADE COUNTY, WMA
METRO -DADS FLAGLER BUILDING
MIAMNDIADE
BUMDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603
PRODUCT CONTROL DIVISION MIAMI, FLORMA 33130-1563
(305) 375-2901 FAX (305) 375-2908
NOTICE OF ACCEPTANCE (NOA)
Polyfoam Products, Inc.
11715 Boudreaux Road
Tomball, TX 77375
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product
Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having
Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the
AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality
assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur
the expense of such testing and the AM may immediately revoke, modify, or suspend the use of such product or
material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO
that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the South Florida Building
Code,1994 Edition for Miami -Dade County or Florida Building Code.
DESCRIPTION: Polyset ® One Roof Tile Adhesive
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 5.
The submitted documentation was reviewed by Mark A. Zehnal, CPRC
NOA No.: 04-1116.01
Expiration Date: 08/24/10
Approval Date: 08/24/05
Page 1 of 5
ROOFING ASSEMBLY APPROVAL:
Category: Roofing
Sub Category: 07320 Roof tile adhesive
Materials: Polyurethane
FILE COPY
- I- SCOPE - -- - -- - — - - - This approves Polyset @ One as described in Section 2 of this Notice of Acceptance, designed to
comply with the South Florida Building Code, Edition for Miami -Dade County. For the locations
where the pressure requirements, as determined by applicable building code, do not exceed the
design pressure values; as obtained by calculations in compliance with RAS 127, using Polyset @
One, and where the attachment calculations shall be done as an moment based system.
2. PRODUCT. DESCRIPTION
Manufactured by
Applicant Dimensions
Polyset One Factory premixed canisters
Product
Description
Single component polyurethane
foam roof tile adhesive
2.1 Components or products manufactured by others:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current
NOA which list moment resistance values with the use of Polyset @ One roof file adhesive.
2.2 Typical Physical Properties:
Proa Test Results
Density ASTM D 1622 1.95 lbsJft.30
Compressive Strength ASTM D 1621 7.8 psi
Tensile Strength ASTM D 1623 19.95 PSI Parallel to rise❑
Water Absorption ASTM-D 2842 4.22 Lbs./Fell
Moisture Vapor Transmission❑ ASTM E 96 3.5 Perm / Inch
Dimensional Stability ASTM D 2126 +0.89% Volume Change @ 70'
C., 2 weeks
Closed Cell Content ASTM D 2856 72.14%11
3. LDWATIONS
3.1 Fire classification is not part of this acceptance.
3.2 Polyset @ One can be used with flat, low, high file profiles.
3.3 Minimum-underlaymentshall be in compliance with the Roofing Application Standard RAS
120.
3.4 Roof Tile manufactures acquiring acceptance for the use of Polyset @ One roof tile adhesive
with their tile assemblies shall test in accordance with RAS 101 with section 10.4 as modified
herein.
3.5 F _ w
P-- 2
MS
NOA No.: 04-1116.01
Expiration Date: 08/24/10-
Approval Date: 08/24/05
Page 2 of 5
4. INSTALLATION
4.1 Polyset One may be used with any roof tile assembly having a current NOA that lists
moment resistance values with the use of Polyset ® One
4.2 Polyset ® One shall be applied in compliance with the Component Application section
and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
-- - -- - - - -- - ---- - -- - -attachment with-the-use-of-Polyset-O-One-shall-provide.sufficientattachmentresistance,-
expressed as an moment based system, to meet or exceed the moment resistance
determined in compliance with Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA
4.3 Polyset ® One roof tile adhesive and its components shall be installed in accordance
with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polyset
One Operating Instruction and Maintenance Booklet
4A Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by
Polyfoam Products, Inc.
4.5 Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after
Polyset ® One has been dispensed.
Polyset ® One placement shall be in accordance with the'Placement Details' herein.
Each generic tile profile requires the specific placement noted herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile
Profile
Typical Placement
Detail
Weight per paddy
Flat, Low & High Profile
# 1
6.5
High Profile 2-Piece
Barrel
# 2
8.7
5. LABELING
5.1 All Polyset ® One containers shall comply with the Standard Conditions listed herein.
6. BUILDING PERMIT REQUIREMENTS
6.1 As required by the Building Official or applicable building code in order to properly
evaluate the installation of this system.
FILE COPY
NOA No.: 04-1116.01
Y Expiration Date: 08/24/10
Approval Date: 08/24/05
Page 3 of 5
Adhesive Placement Details
riL COPY
NOA No.: 04-1116.01
Expiration Date: 08/24/10
Approval Date: 08/24/05
Page 4 of 5
ADimswE PLACEMENT DETAILS
(CONTnwED)
PLACEMENT DETAIL # 2
END OF THIS ACCEPTANCE
FILE C-OPY
NOA No.: 04-1116.01
Expiration Date: 08/24/10
Approval Date: 08/24/05
Page 5 of 5
t /
TAMKO® MOe30 ASTM
RODUCT DATA
t Saturated Organic Felt
Manufacfured in Green Cove Spmngs, FL.,
TAMKO® NO.. 30 ASTM SATURATED FELT features a
premium quality TAMKO organic felt (non -perforated) that
is saturated with asphalt.
Accepted for use as an underlayment felt to be applied
over the deck prior to the installation of TAMKO asphalt
shingles.
Underwriters Laboratories Prepared Roofing Accessory
ASTM D 226, Type If
Roll Dimensions 72' X 36"
Coverage per roll 2 Squares
Laying Lines 2", 4", 17"
'All values stated as nominal
FILE COPY
CAUTION: The National Institute for Occupational Safety and Health (NIOSH) has
concluded that fumes of heated asphalt are a potential occupational carcinogen.
Do not heat or bum this product.
j I�mI�V'
Visit our Web Site at www.tamko.com
ROOFING PRODUCTS
Central District
Northeast District
220 West4th St., Joplin, MO
64801
ozrzooa
800-641-4691
TAMKO Logo, Roofer Logo, andTAMKcr
Southeast District
4500 Tamko Dr., Frederick, MD
2300 35th St., Tuscaloosa, AL
21701
800-368-2656
are registered trademarks of
TAMKO* Roofing products, Inc.
Southwest District
Western District
7910 S. Central EX ., Dallas, TX
p
35216
800-228-1834
800-530-1868
5300 East 43rd Ave., Denver, CO
80216
80216
800-530-8868
M 1 A M I-DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
1 PRODUCT CONTROL DIVISION
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
NOTICE OF ACCEPTANCE (NOA)
CeriainTeed Corporation (PA)
1400 Union Meeting Road, P.O. Box 1100 ��� %
Blue Bell, PA 19422
SCOPE:
This NOA iG being issued under the applicable rules and regulations governing the use of construction
materials. '-'-'.le documentation submitted has been reviewed by the 13CCO and accepted by the Building
Code and Product Review Committee to be used in Miami Dade County and other areas where allowed
by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County)
and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material
tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,
the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke
this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code and the Nigh Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems Over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this N-OA will occur after the expiration date or if there has been a revision or
change in ide'niaterials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayer:, then it shall be done in its entirety.
INSPEC'11ON: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distribuwrs and shall be available for inspection at the job site at the request of the Building Official.
This NOA renevis NOA No. 03-0827.02 and consists of pages 1 through 39.
The subntted documentation was reviewed by Jorge L. Acebo.
NOA No.: 08-0227.09
MIAMbDACEcou�n Expiration Date: 06/19/13
... � Approval Date: 05/15/08
Page 1 of 39
ROOFING AsSEMBLV APPROVAL
y Category-, Roofing
Sub -Category: APP/SBS Modified Bitumen
Deck Type: Wood
Maximum Design Pressure -60 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1.
Test Product
odu Dimensions Specification Description
tl I11k2ther it36" x 7T, Roll ASTM D 2626 UL Asphalt coated organic base sheet.
weight: 86 lbs. Type 15
(2 squares)
Flex-I-GlasTM Base 36" x 108', Roll UL Type G2 Modified Bitumen coated fiberglass base
Sheet weight: 90 lbs. ASTM D 4601, sheet.
(3 squares) type H
Flex-I-GlasTM FR Base 39 318" x 50', Roll UL Type G2 Modified Bitumen coated fiberglass base
Sheet weight: 90 lbs. ASTM D 4601, sheet.
(1.5 squares) type II
Flintglas® Ply Sheet 36" x 1-80', Roll ASTM D 2178 Fiberglass, asphalt impregnated ply sheet.
Type IV or V1 weigr .: 40!55 lbs. Type IV or VI
(5 squares) UL Type G1
Flintlastic STA 39 3/s" x 33', Roll ASTM D 6222, Smooth surfaced APP Modified Bitumen
STA Plus 5.0 weight: 90 lbs. Grade S, Type II membrane with non -woven polyester mat
(1 square) reinforcement for torch application.
Flintlastic GTA, GTA- 39 3/g" x 33' 3", Roll ASTM D 6222, Granule surfaced APP Modified Bitumen
FR or Flintlastic weight: 105 lbs. Grade G, type II membrane with non -woven polyester mat
Diamond GTA (1 square) reinforcement for toch application.
Flintlastic GTS 39 3/g" x 249", Roll ASTM D 6164, Granule surfaced SBS Modified Bitumen
weight: 92 lbs. Grade G, Type II membrane with non -woven polyester mat
(3 square-) reinforcement for torch application.
Flintlastic G-A,!S, 39 3/8
.' x 34 2", Roll ASTM D 6164, Granule surfaced SBS Modified Bitumen
Premium GMS weight: 100i 105 lbs. Grade G, Type H membrane with non -woven polyester mat
(1 square) reinforcement for mop application.
Flintlastic FR-P, 39 3/8" x 34` 2", Roll ASTM D 6164, Fire resistant, granule surfaced SBS
Premium FR-P weight: 105 lbs. Grade G, Type I Modified Bitumen Membrane with non-
(1 square) woven polyester mat reinforcement for
mop application.
Flintlastic FR Cap 39 3/R" x 34' 2", Roll ASTM D 6163, Fire resistant, granule surfaced SBS
weight: 90 lbs. Grade G, Type I Modified Bitumen membrane with
(1 squaael/ fiberglass mat reinforcement for mop
applications.
Flexiglas Premium Cap 36" x 3C ASTM D 6163, Granule surfaced SBS Modified Bitumen
960 (1 square) Grade G, Type I membrane with fiberglass, mat
reinforcement for mop application.
NOA No.: 08-0227.09
MMIAMIODADECOTFILE COPY
Expiration Date: 06/19/13
Approval Date: 05/15/08
Page 2 of 39
APPROVED FASTENERS:
TABLE 3
Fastener Product
Product
Manufacturer
Number Name
Description
Dimensions (With Current NOA)
L 412 & #la Dekfast
Insulation fastener
Construction Fasteners, Inc.
Fastener
2. Dekfast Hex Plate
Galvalume AZ50 steel plate
2 7/8" x 3 I/a" Construction Fasteners, Inc.
3. Olympic. Fastener #12-�Insulation fastener
Olympic Manufacturing
& 414
Group, Inc.
4. Olympic Standard
3" round galvalume AZ50
3" round Olympic Manufacturing
steel plate
Group, Inc.
5. insul-Fixx Fastener
Insulation fastener for steel
SFS Stadler, Inc.
and wood decks
6. Insul-Fixx S Plate
Galvalume AZ50 steel plate
3" round SFS Stadler, Inc.
7. Tru-Fast Fasteners
Insulation fastener for wood
The Tru-Fast Corp.
and steel decks
8. Tru-Fast MP-3
Galvalume AZ50 steel plate
3" round The Tru-Fast Corp.
9. Tru-]�ast Plates
Galvalume AZ55 steel plate
3" round The Tru-Fast Corp.
10. Tru Fast Plates
Polyethylene plastic plate
3" round The Tru-Fast Corp.
EvIDENCE SUBMITTED:
Test Agency
Name
Reuort Date
Applied Research Laboratories
Physical Properties
28013 06/02/87
Factory Mutual .Research
Current Insulation Fastening
FMRC 1994 01/01/95
Corporation
Requirements
Factory Mutual. Research
PA 114
J.I. #3Y8A1.AM 03/23/96
Corporation
(FMRC 4470)
Jnderwriters Labo.:_atories, Inc.
Fire Classification
R11656 07/13/87
Compliance
United States Testing Company,
ASTM D 5147
97457-4 06/03/88
Exterior Research & Design, LLC
TAS 114 (J)
#3507.08.99-1 04/18/01
Exterior Research & Design, LLC
#3514.02LAB 11/11/02
Exterior 1?e ear-, & Design,, LLC
TAS 114
#3515.07.03 07/22/03
TAS 117
FILE COPY NOA No.: 08-0227.09
r Expiration Date: 06/19/13
MIAP+ I- �D - COUPfrf
Approval Date: 05/15/08
Page 4 of 39
;, Membrane Type:
6 Deck Type 1:
APP MODIFIED
Wood, Non -insulated
Deck Description: Minimum 19/32" thick plywood attached using wood screws spaced 6"o.c. at wood
joists spaced maximum 24" o.c.
System Type E(;): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet:
One ply of Glas Base, Flex -I Glas Base, Flex-1 Glas FR Base or All Weather /
Empi; a Ease ' hae__ t mechanically fastened as detailed bel_ low.
Fastening:
Base sheet shall be lapped 4" and fastened with Simplex Mega Cap Nails spaced
9"o.c. in the lap and 9" o.c. in two staggered rows in the center of the sheet.
Ply Sheet:
((Optional One ply of GlasBase, Flex-I-GlasBase, Flex-I-Glas FR Base, PolySMS
or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply
Sheet (Type VI) adhered to the base sheet in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq.
Membrane:
Flintlastic STA, Flintlastic Diamond GTA, Flintlastic GTA or GTA-FR torch
adhered to base or ply shee
Surfacing:
(Optional) Install one of the following:
1. 400-lb./sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping
asphalt at an application rate of 60 lb./sq.
2. Karnak 97, FlintCoat A-150, APOC 212 Fibrated Aluminum, Henry 520
Aluminum or Grundy AL MB at an application rate of 1 1/z gal. /sq.
Maximum Design
Pressure:
-60psf. (See Czeneral Limitation #7)
FILE COPY
MEL NOA No.: 08-0227.09
MIAMI-DADE COU1VTY
Expiration Date: 06/19/13
Approval Date: 05/15/08
Page 37 of 39
l
WOOD DECK SYSTEM LIMI`.CATIONS:
" 1. A slip sheet is required wish Ply 4 and Ply 6 when used as a mechanically fastened base or anchor
sheet.
GENERAL U-miTATIONSa
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-401bs./sq., or mechanically attached using
the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' r. 4` maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a
corrtiiatious area of ventilation. 'Encircling of the strips is not acceptable. A 6" break shall be placed
every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a
ardninium rate of 12. lbs.isq.
Note. Spot attached systerths shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for in.3111aticla attachment is based on a Minimum Characteristic Force (F) value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as
field-tested, are below 275 l'of. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on
a mu irriurn fastener resistance value in conjunction with the maximum design value listed within a
specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered
Prol�sioiaal Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said
ra+i isad fastener spacing shall utilize the withdrawal resistance value taken from Testing Application
Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117.
7. Puri-rieter and com'zx areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener dt rnsldr;% slAdll be increased for both insulation and base sheet as calculated in
compliance with Roof-.iig Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered 'Professional Engineer, Registered Architect, or Registered Roof Consultant
\�YL.en thts l unitaflon is specifically referred within this NOA, General Limitation #9 will not be
applicable;.)
8. All attacliant:nt and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall
co_} crm to Roofing Application Standard RAS 111 and applicable wind load requirements.
The :aia.K.L aurn designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
�J fie i,i, perimeters, and c.:rners). XIeither rational analysis, nor extrapolation shall be permitted for
eriiaar_ced fastening at aMiiceci i,ressure zones (i.e. perimeters, extended corners and corners).
(4,"Viie;n this liinitamiiFout ;; spec Oizally referred within this NOA, General Limitation #7 will not be
applicable.)
10. All l.r::}chwc s iisted Lxeie ,hall_ have a quality assurance audit in accordance with the Florida Building
Code and Rule S5-72 of :he rloLida Adnunistrative Code.
END Off` THIS ACCEPTANCE
r;I� NLlil tF Cop
NOA No.: 08-0227.09
rp1pr
ation Date: 06/19/13
,;t'•y�(; ;. o II`; rovai Date: 05/15/08
Page 39 of 39