Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDate: 'G/krJW • I Fee Due: w Permit # 1. Location/Site Address: 2. Parcel ID Number: 3. Descr St. Lucie County Building & Zoning 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 Tel. 772-462-1553 APPLIC CIO ON FOR ROOF PERMIT 111161 Office Use Only Section TownshipRange Ma Pa Zonin Land Use Initials ?) 40 P40W 1(1 S lZ.y iption of Project or Work Activity: -Q �p 4. Total Roof Area (square feet): 5. Roof Pitch: 6. Type of Roof: El Fiberglass Shingle Barrel/Tile Ceramic ❑Wood Shake Shingle ❑Tar &Gravel Modified Bitumen ❑Metal ❑Other (specify) N.O.A - Product Approval required for All Types of Roofing Material ❑ All Commercial Roofing Requires Design by an Engineer or Architect (two Sets) 7. Owner Name: Address: City: Zip: t 1 rig 8. Contractor FL Reg/Cert #: County Cert#: State: ­-1(__- " Business Name: Phone: �17U('d3q Phone 9. Value of Construction: $ Ivy Note: Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval OWNER'S AFFIDAVIT: I certify that all of the information contained in this applic tion is orrect and that all work will be done in compliance with all applicable la ons uc ton o ing. VVA A L,1' 4WLS ` o PRINT, QUALIFIERS/OWNERS NAME SIGNATURE OF QUALIFIER/OWNER 7: STATE OF FLORIDA, COUNTY OF � G t GED BEFORE ME THIS DAY OF 202S BY •) Ontr( ._ `}� ((�DYI HO IS PERSON Y KNOWN TO ME OR WHO HAS PRODUCED .. . :•s.euunumunuuunnN AS IDENTIFIC_ IRISHA NEAL MIGLEY COMM#DD0706197 '- GNATU E OR RINT N OF T S;R Expires 8I251�4��i ����� Flortda NoteryAsan.. h1C ; TITLE: NOTARY PUB C COMMISSION NUMBER nrea®..euuu.e.e. 6uu..H St. Lucie County Roof Permit Application rev. 10, Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Review Comments PROPERTY INFORMATION Address: 3805 PROMENADE WAY City / State / Zip: FORT PIERCE FL 34982 Parcel # : 2433-502-0041-000/6 Jurisdiction: St. Lucie County Zoning: RS-3 Lot # : 41 Block: APPLICATION INFORMATION Permit Number: 0807-0148 Activity Type: Permit Type: Roof CONTRACTOR INFORMATION Contractor Name: TIMOTHY HUTCHINSON Business Name: ON SHORE ROOFING SPECIALISTS INC Business Addr: 915 E OCEAN BLVD SUITE E City / State / Zil STUART, FL 34996 REVIEWS AND COMMENTS Review Type Status Plans Examiner Review Incomplete Page 1 Owner(s): FRANCOIS A KAIS Application Type: Over the Counter Permit Other Activity: Stories: 1 Automatic Sprinkler System? Fax Number 772-287-1303 Reviewed By Date Started Date Complete Date Released Joe Cicio 07/10/2008 07/10/2008 1 Comment CONTRACTOR TO SUBMIT SECTION R4402.14 IN DUPLICATE FOR REVIEW WITH THIS PERMIT [ UNIFORM PERMIT APPLICATION] 07/10/2008' 2 Comment SUBMIT THE RAS 118, 119,.120 SPECS PROPOSED FOR THIS JOB HIGHLIGHTED IN DUPLICATE' 07/10/2008 3 Comment CONTRACTOR TO HIGHLIGHT THE MIAMI-DADE PRODUCT APPROVALS FOR THE HANSON TILE 07/10/2008 4 Comment SUBMIT A LETTER AS TO WHICH ENGINEERING FIRM WILL BE PERFORMING THE UPLIFT TESTING 07/10/2008 5 Comment SUBMIT THE PRODUCT APPROVAL FOR THE TILE UNDERLAYMENT IN DUPLICATE 07/10/2008 6 Comment COMMENTS MAILED TO OWNER AND CONTRACTOR AS OF THIS DATE 2008-07-1615:24 PINEAPPLE 7722871303» 7724625443 P 1/4 -7� pzol �y i 01 V Jul 16 08101;52p Katherine Clev.. , 561 W39 P.1 Cleary Inspection Services, Inc_ Fax (661) M-8038 Office (661) 682-0114 Cell (561) 722-9881 ly. (� ' ne •�� _ 106 Tile Uplift TEST INFORMATION SHEET roject Name: roject Address: ress Erlephone Number Cell 3tal Square Footage �-bC� No. of Elevations umber of Stories s _�` Need Ladder & size: require a 28' ladder Contractor to secure ladder ermit # oof Fitch le Installation Date ment Method Attachment NCA: facturer we need to contact owner prior to inspectic YES NO ner Name & Telephone Number TED COMMUNITY ENTRANCE INSTRUCTIONS �r 7, VA,d N49MUL [<SO£6L8ZZLL 31ddV3NId 0%9VLO-800Z Miami -Made County, Florida 1 - Building Coda Coinpikince Office Sure 1603 Laboratory Certificate - '''�"''� ~ iaR West Flaslar Sweet -� �= Miami. Florida 33130.1563 r, (305) 375-2901 Fax (305) 375-2908 lea. = that e&4V %aa/=4W SM4M, %0. 4C44d at 187.5 72, ;Paww", Zags WW4, V S3460 Cab CELL 17amcq ZaAft8av 4% QadwluG a&g Mime Vale "ate eAk& &*&4ete aad Paotacal 'USSOI - 94, a&d ea &rti a to ^qawu TAS 105 TAS 106 TAS 126 (Nuclear method only) Read & 4 tfm a4oe w&rt ft a' teat aia& Ge AwAe4 au matr d ra %asxri - Dade e4gfftt TOC44V d04 &M*"OdeO t4 Aga. A#wOa( M#g=r0 �X ffea &4w4wf: RN, Sailappan, P.E. This Cert(ication and Registration Approved: May 11, 2006 This CertWation and Registration Expires : May 11, 2011 t:ertifieation No.: 05-090116 Ja 1), Gascon, P.9. Jerry HernetezChief Senior QualiAss yrance InspectorProduct Control Division Product Conof vision 4e %a" -Dude 6uW4 �c � Glade �aaAr�rtluctce O#see ae-� do W*& to a OOM flue WSW" �ft Owa - OwA&uce wt 44 wdeda#d xqgapt 4 Pie USSOI - 94. NACERTMC1LA.BOR.NTMOSIO i.due WE d £bt,9Z9VzLL <[ £O£6L8ZZLL . 3lddd3Nld bZ'gl 91-LO-8OOZ Certified Testing Laboratories 7252 Narcoossee Rd. Orlando, FL 32822 Contact: William Blakely, Ramesh Patel, P.E. Ph 407-384-7744 Fax 407-384-7751 Expiration Date: 01/17/12 CEL Consulting Division of. Quality Assurance Engineering, Inc. 534 23rd Avenue Oakland, CA 94606 Contact: Lee Mattis, P.E. Ph 510-436-7626 Fax 510-434-7719 Expiration Date: 10/14/11 1813 N. Palmway — ®@ Lake Worth, FL 33460 Contact: Katherine I. Cleary R.N. Sailappan, P.E. Ph 561-722-9881 Fax 561-582-8039 Expiration Date: 05/12/11 Construction Consulting Laboratory Int'l. 1601 Luna Road Carrollton, TX 75006 Contact: Kenneth H. Lloyd Jr.,PE Abdol H. Rezadad, P.E. Andy Wilson Ph 972-242-0556 Fax 972-245-6047 Expiration Date: 05/17/11 P:\PRODCNTL\LABS\APPROVED\ApprovedLabs93.doc Internet mail address: BCCnnmiamidade.gov TAS201 TAS202 TAS203 TAS 114 App. D TAS 114 App. J TAS 125 AAMA 103.3-89 Section 5 ASTM D25 6 ASTM D638 ASTM D790 ASTM E8 ASTM E10 ASTM E23 ASTM E72 ASTM E94 ASTM E164 ASTM E165 ASTM E587 ASTM E709 ASTM E783 ASTM E987 ASTM E1004 ASTM E1105 ASTM E1444 ASTM E1592 AWS D1.1 & AWS D1.2 MIL -STD 6866 International Accreditation Services, Inc. Certificate of Accreditation TL-173 International Accreditation Services, Inc. Certificate of Accreditation AA-639 TAS 105 TAS 106 TAS 126 (Nuclear method only) TAS201 TAS202 TAS203 Homepage: Mtn://www.miamidade.gov/buildingeode FROM: STEVENS. WOOD, P.E. FL P.E. LICENSE No. 34398 950 SULTAN DR PSL, FL 34953 TO: ST. LUCIE COUNTY BUILDING DEPT. 2300 VIRGINIA AVE FT. PIERCE, FL 34982 AUGUST 16, 2008 SUBJECT: CERTIFICATION FOR RE -ROOF HOT -MOP DRY -IN CONSTRUCTION REFERENCE: PERMIT No. '.� - D S-d FIFI KRIS RESIDENCE 3805 PROMENADE WAY FORT PIERCE, FL 34982 THE PURPOSE OF THIS LETTER IS TO CERTIFY THE HOT -MOP PORTION OF THE DRY -IN CONSTRUCTION AT THE ABOVE REFERENCED ADDRESS. THE ROOF WAS DRYED-IN TO PREP FOR TILE INSTALLATION WHICH HAS SINCE BEEN COMPLETED. BASED ON INSPECTIONS AND DISCUSSIONS WITH THE CONTRACTOR, THE FOLLOWING FINDINGS WERE MADE: • THE EXISTING ROOF SLOPE/PITCH IS APPROX 5:12. • HOT MOP DRY -IN CONSTRUCTION CONSISTED OF: o 90# ASHPALT ASTM MEMBRANE WAS INSTALLED WITH HOT ASPHALT TAR/MOP METHOD USING 4" MIN LAP. o LAPPED JOINTS WERE BACK -NAILED @ 12" CENTERS WITH 14" CAPS PRIOR TO HOT MOP BASED ON THE ABOVE FINDINGS, THE RE -ROOF HOT -MOP DRY -IN CONSTRUCTION IS IN COMPLIANCE WITH THE 2004 FBC (INCLUDING 2005 & 2006 SUPPLEMENTS) FOR 140 MPH WIND ZONE AND EXPOSURE 'B' CLASSIFICATION. THEREFORE, THE HOT -MOP DRY -IN CONSTRUCTION IS ACCEPTABLE AS IS. AUG �22 ?008 fit. �Cb/iC W STEVEN G. WOOD, P.E. k �� Coy ra �� FL LICENSE 34398 t a� FROM: STEVENS. WOOD, P.E. AUGUST 16, 2008 FL P.E. LICENSE No. 34398 950 SULTAN DR PSL, FL 34953 TO: ST. LUCIE COUNTY BUILDING DEPT. 2300 VIRGINIA AVE FT. PIERCE, FL 34982 SUBJECT: CERTIFICATION FOR RE -ROOF HOT -MOP DRY -IN CONSTRUCTION REFERENCE: PERMIT No.�- Oft T �l FIFI KRIS RESIDENCE 3805 PROMENADE WAY FORT PIERCE, FL 34982 THE PURPOSE OF THIS LETTER IS TO CERTIFY THE HOT -MOP PORTION OF THE DRY -IN CONSTRUCTION AT THE ABOVE REFERENCED ADDRESS. THE ROOF WAS DRYED-IN TO PREP FOR TILE INSTALLATION WHICH HAS SINCE BEEN COMPLETED. BASED ON INSPECTIONS AND DISCUSSIONS WITH THE CONTRACTOR, THE FOLLOWING FINDINGS WERE MADE: • THE EXISTING ROOF SLOPE/PITCH IS APPROX 5:12. • HOT MOP DRY -IN CONSTRUCTION CONSISTED OF: o 90# ASHPALT ASTM MEMBRANE WAS INSTALLED WITH HOT ASPHALT TAR/MOP METHOD USING 4° MIN LAP. o LAPPED JOINTS WERE BACK -NAILED @ 12" CENTERS WITH 14" CAPS PRIOR TO HOT MOP BASED ON THE ABOVE FINDINGS, THE RE -ROOF HOT -MOP DRY -IN CONSTRUCTION IS IN COMPLIANCE WITH THE 2004 FBC (INCLUDING 2005 & 2006 SUPPLEMENTS) FOR 140 MPH WIND ZONE AND EXPOSURE W CLASSIFICATION. THEREFORE, THE HOT -MOP DRY -IN CONSTRUCTION IS ACCEPTABLE AS IS. STEVEN G. WOOD, P.E. FL LICENSE 34398 Public Works Department Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 INSPECTION AFFIDAVIT RE: Permit # D O% — V %av / o ,Iicensed as (n) Contra c r*/Engineer/Architect/ (Please print name a d circle license type) 468 Building Inspector* * General, Building, Residential, o 0o n Contract r or any individual certified under 468 F.S. to make such an inspection. All affidavits must inc graphs of each plane of the roof with the permit # or address # clearly shown marked on the deck for each inspection. On or about 4-0 �' , I didpersonally inspect the roof (Date & time) deck nailin and/or seconddry water barrier work at (circle one) 1 C-C, . (Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mi igat' n Retrofit Manual (Based on 553.844 F.S.) `Z Signature & Sear License # STATE OF FLORIDA COUNTY OF ( A9 C jl 1 Sworn to and subscribed befcae me this day of .200 by f I.` 1� 11 . Who(ersonall own or who has produced s,, •o as identification.. _ < ruu■■.■■■■■.■■■■.■■.*■unu■ n,�. C, L QUIGLE TRISHA NEA%�����' Notary Public, State of Florida o Comm# 1)130706% a Signature of Notary: eu Expires 8/2s/2011 .� y ' Florida Notary Assn., Inc . w■■..■.■■.■■■■..,.■.....■■.■.■■■■■■■■ua: Commission No.: ....(Seal) cml 9/27/07 EDWIN M. FRY, Jr., CLERK,OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 3233519 OR BOOK," �)5 PAGE 2681, Recorded 07/17 �D8 at 01:11 PM NOTICE OF COMMENCEMENT TO BE COMPLETED WHEN CONSTRUCTION VAL UE EXCEEDS $2,500,00 PERMIT #: TAX FOLIO H: STATE OF FLORIDA COUNTY OF MARTIN THE UNDERSIGNED HEREBY GIVES NOTICE THAT IMPROVEMENT WILL BE MADE TO CERTAIN REAL PROPERTY, AND IN ACCORDANCE WITH CHAPTER 713, FLORIDA STATUTES, THE FOLLOWING INFORMATION IS PROVIDED IN THIS NOTICE OF COMMENCEMENT. PROPERTY GENERAL DESCRIPTION OF OWNER NAME: INTEREST IN PROPERTY: aon P NAME AND ADDRESS OF FEE SIMPLE TITLE HOLDER (IF OTHER THAN OWNER): CONTRACTOR: ADDRE PHONE SURETY COMPANY (IF ANY): ADDRESS: PHONE NUMBER: _ BOND AMOUNT: LENDER/MORTGAGE COMPANY: ADDRESS: FAX L—e- —Y 22 PERSONS WITHIN THE STATE OF FLORIDA DESIGN BY OWNER UPON WHOM NOTICES OR OTHER DOCUMENTS MAY BE SERVED AS PROVIDED BY SECTION 713.13 (1) (a ., FLORIDA STATUTES: NAME: ADDRESS: PHONE NUMBER: FAX NUMBER: IN ADDITION TO HIMSELF HERSELF, OWNER DESIGNATES OF TO RECEIVE A COPY OF THE LIENOR'S NOTICE AS PROVIDED IN SECTION 713.13(IXB), FLORIDA STATUES. PHONE NUMBER: FAX NUMBER: EXPIRATION DATE OF NOTICE OF COMMENCEMENT: (THE EXPIRATION DATE IS ONE (1) YEAR FROM THE DATE OF RECORDING UNLESS A DIFFERENT DATE IS SPECIFIED). WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMTICING WORK OR RECORDING Y91 NOTICE OF COMMENCEMENT. . 11 ;ts ��o n --.? g( - - -& 9 RE ' 7�6 OF OWNER OR O NIXS AUTHORIZED OFFIC HIECTOR/PARTNE NAG R agnev SIGNATORY'S TITLE/OFFICE THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS Ie DAY OF f/ 00' BY: AS FAR NAME OF TYPE WHOM INSTRUMENT WAS EXECUTED PERSONALLY KNOWN-9RIkRODUCED IDENTIFICATION �r F IDET r v P O C Z- yP w N NoGot P Farrell Public State of Flodda My Commission DD636437 Y SI ATUR NOTARY SEAL Va tidy�' V, 1 - !` Expires 03121/2011 V.ND*PENALTIES OF PERJURY, I DECLARE THAT 1 HAVE READ THE FOREGOING AND THAT THE FACTS IN IT ARE U TO THE BEST OF MY KNOWLEDGE AND BELIEF (SEC ?I�I9'1,5�C"WrfjII"' OTVTES) aT. Li I C I E COUNTY ( ra of Natural Person Signing bov 10 u E R r I fY T H AT ? H I S I S A �� L AND uCaR RECT COPY Or THE HN Rj By �c Co U n' Oat'n: �BI r� —a �F 0' E F ROOF ASSEMBLIES AND ROOFTOP STRUCTURES oc IF— �' W CMQM a- o � ®C3�� ata ®im CO W Uj a- = cu W Nca R Cal SECTION 1525 HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2004 High -Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE FILE COP COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation FLORIDA BUILDING CODE — BUILDING 15.31 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2004 High -Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. Contractor's Name r Job Address FILE COPY ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile )(Mortar/Adhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes Shingles Q9► Prescriptive BUR-RAS 150 / ROOF TYPE ❑ New Roof Reroofing ❑ Recovering ❑ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Q Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) �( > Total (SF) I / 111 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 15.32 FLORIDA BUILDING CODE — BUILDING FILE Cop', OT FI'LE COPY ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2004 High -Velocity Hurricane Zone Uniform Permit Appli ation Form. Section C (Low Slope Application) Surfacing'v'(9V Fill in specific roof assembly components and identify manufacturer Fastener Spacing for Anchor/Base Sheet Attachment: (if a component is not used, identify as " NA") a - Field: " oc @ Lap, # Rows 3 @ �" oc System Manufacturer:` P 1. . Perimeter: " oc @ Lap, # Rows -F @ ' oc Product Approval No.: 7i v orner. oc @ Lap, it Rows @ oc Design Winne : Pressures, Fro RAS izo or Calculations: Pmax1/ Pmax2:' Pmax3: 1 `3 Max. Design Pressure, from the recif Product Approval system:_ _ Deck: Anchor/Base Sheet & No. of Ply(s): `(.6 An or/Bas Sheet Fasten Bondin Mate ial - j Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Materi : Top Insulation Layer: Top Insulation Size and Thic ess: Top Insulation Fastener on in M 'al: Base Sheet(s)/tener/IB3onding Ply(s). Base Sheet F Material: Ply ZShe(s) & No. of Ply(s): Ply Fastener/Bonding Material: Top Ply: l Top Ply Fastener/Bonding Material: f� 1 Number of Fasteners Per Insulation Board: Field PerimDelfnDetalls Corner Illustrate Compo is as Applicable: Woodblocking, Gutter, Edge Te ' ation, Stripping, Flashing, Continuous Cleat, Cant Strip, Base shing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit 04 41 Mean Roof .1 Height FLORIDA BUILDING CODE — BUILDING 15.33 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES W LLM Florida Building Code Edition 2004 High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based file systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the file attachment method is acceptable. ethod 1 "MomentB sedT Calculat S 127" (PI: x i =�) Mg. i Mrl-LProduct Approval Mf . (P2. x ],'� - ) - Mg: = Mr2� 3 Product Approval Mf (Pg: x X ) - Mg. o = M. _ Product Approval Mf Method 2 "S' pH ed imow le Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Belo' i Product An oval Mf 1 -G- Mr required Moment Resistance* Mean Roof Height Roof Slope 1 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 1 32.6 1 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values forF' with the values forFr.If the Fvalues are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Moment Based Tile Calculations Per RAS 127" (PI: x L = x w: = ) - W: x cos B = Frl Product Approval F (P2: x L = x w: = ) - W: x cos 0 = Fr2 Product Approval F (P,: x L = x w: = ) - W: x cos 0 = F- Product Ancroval F Where to Obtain Information Description Symbol Where to find Design Pressure PI or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier x Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance X1 Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = lengthProduct W =width Approval All calculations must be submitted to the building official at the time of permit application. FLORIDA BUILDING CODE - BUILDING 15.35 Sj TION 1524 HIGH -VELD("- '�Y HURRICANE REQUIR�D OWNERS N... Pagel of2 FILE -COPY SECTION J1524 HIGH -VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1.Scope. As it pertains to. this section, it is the responsibility with the required roofing permit, and to explain to t provisions. of Chapter 15. of the Florida Building Cc requirements and standards of the industry for roof .following items should be addressed as part of the contractor. The owner's initial in the designated sp WnepldAesthetics-workmanship: The works Velocity Hurricane Zone) are for the purpoE the wind resistance and water intrusion per are not a consideration with respect to wort as color or architectural appearance, that a Ai addressed as part of the agreement betwe4 the roofing contractor to provide the owner owner the content of this section. The Building -govern the minimum g system installations. Additionally, the treement betweenthe owner and the e indicates that the item has been inship provisions of Chapter 15 (High - of providing that the roofing system meets �mance standards. Aesthetics (appearance) unship provisions. Aesthetic issues such not part of a zoning code, should be the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have. to be renailed in accordance with the current provisions of Chapter 16_(High- Velocity Hurricane Zones) of the. (The roof tleck is usually concealed prior to removing the existing roof system.) I . ® 1. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be perform. AExposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water:. The current roof syst well and may cause water to pond (accumi can be an indication of structural distress a structural engineer. Ponding may shorten t �t new roofing system. Ponding conditions m; �t\ 'stem is removed. Ponding conditions shi 16.. Overflow scuppers (wall outlets): It roof is not overloaded from a buildup of wa extensions may -block this discharge if over It may be necessary to install overflow scut hapter 15 and 16 herein and the Florida I 7. Ventilation: Most roof structures shoe through the interior of the structural asseml attic ventilation shall not be reduced. It mai which can result in extending the service lit i and/or deck of the building may not drain te) in low-lying areas of the roof. Ponding may require the review of'a professional life expectancy -and performance of the not be evident until the original roofing d be corrected. required that rainwater flow off so that the Perimeter/edge walls or other roof . w scuppers (wall outlets) are not provided. .rs in accordance with the requirements of: Iding Code, Plumbing. d have some ability to vent natural airflow ly (the building. itself). The existing amount of be beneficial to consider additional venting of the roof. '/ecodes.iccsafe.org/icce/gateway FL/294/318?f=te... 3/20/2008 :11V1N 1:)Z4 HILIH-VbLU, Y HUMUL;Alvh GV1Vrra— KEQUMl I) OWNEKS N... Page 2 of 2 Owner's/Agent's Signature Date Contractor's Signature %ecodes.iccsafe.org/icce/gateway 18?f=te... 3/20/2008 ROOFING APPLICATION STANDARD (RAS) No. 120 MORTAR AND ADHESIVE SET TILE APPLICATION 1. Scope This application standard covers the procedures for installation of mortar or adhesive set roof tile systems. This standard shall be used in conjunc- tion with the tile manufacturer's Product Ap- proval and RAS 127. 2. Definitions For definitions of terms used in this application standard, refer to ASTM 1079 and the Florida Building Code, Building. NOTE #1: The following table provides the contractor with the choices available for underlay systems. These systems can only be used on pitches designated in the ta- ble below: FILE COPY Roof Pitch _ Choice of Underlayment Plastic or Compatible Roof Cement at Nails Penetrating Underlayment Reference 1. ASTM D 226 Type I4 #30 or ASTM D 2626 _ _ 2:12 or greater (#43) inorganic base nailed to deck, min ASTM D 249 Required 3.01 A (#90) organic cap sheet se in Type IV hot asphalt. 2. Any product approved underlayment system with a mechanically fastened base sheet, and cap sheet per Product Approval 3.01 B, C, or D set hot, cold, or self adhered. FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) 120.1 (RAS) No. 120 u' This Rooting Application Standard covers flat, low 1. Fasteners shall be in, a„ and high -profile roof tile, using a minimum 2 in. the compliance with Section headlap, or design limited headlap as specified in 1523 of the Florida tile manufacturer's Product Approval. Installed on Building Code, Building I I minimum 15/32 in. solid decking nailed in compli- (herein referred to as , ance with Chapter 23 (High -Velocity Hurricane "Approved Fasteners"). Zones) of the Florida Building Code, Building. a ils shall be mini - PART I -GENERAL rnum 12 gage, an- nular ring shank nails having not 1.01 less than 20 rings per inch; heads not A. Tiles:' 'hall not be installed over less than 3/K in. in diameter; and wet underlayment where moisture lengths sufficient to prohibits adhesion of mastic, mor- penetrate through tar, or adhesive. the plywood panel or wood plank decking not less than 3/16 in., or to PART 11- MATERIALS penetrate into a 1 in., or greater, 2.01 Fasteners: thickness of lumber not less than I in.. Nails shall be hot A. Tile Fasteners: dipped; electro or mechanically gal- vanized to a thick- ]. All roof file nails or fasten-, ness sufficient to ers, except those made of resist corrosion in copper, Monel, aluminum, compliance with or stainless steel, shall be Appendix E of tested for corrosion in com- TAS 114. All nails pliance with TAS 114 Ap- shall have Product pendix E, Section 2 (ASTM Approval. All nail G 85), for salt spray for cartons or carbon 1000 hours. Tile fasteners labels shall be la - used in coastal building beled to note corn - zones, as defined in Chapter pliance with 16 (High -Velocity Hurri- ion-resis- cane Zones), Florida Build- ance requirements. tance r I ing Code, Building shall be copper, monel, aluminum, or stainless steel. (bb) Such fasteners shall All roof tile fasteners shall be be applied through "tin caps" not less of sufficient length to pene- than 1518 in. and not trate a minimum '/, in. more than 2 in. in I I through the thickness of the diameter and of not deck or batten, whichever is less than 32 gage less, or to penetrate into a 1 (O.O10 in.) sheet I I in., or greater, thickness of metal. All tin caps lumber not less than 1 in. shall have Product Approval. B. Underlayment Fasteners: (RAS) 120.2 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ 1 _ \ (RAS) No. 120 (cc) Prefabricated fas- B. Cold process modified bitu- ,� tener systems coin- men roofing mastic - conform - plying with Section ing to ASTM D 3019, Type III. 1517.5. Florida Building Code, Building may be C. Asphalt - conforming to used, (provided they ASTM D 312, Type IV. II have Product Ap- proval). 2.04 Adhesive/Sealant: 2.02 Metal Flashing: A. Structural bonding adhesive - conforming to ASTM 3498. A. Flashing materials shall comply with the requirements set forth in 2.05 Mortar: Chapter 15 (High -Velocity Hurri- cane Zones) of the Florida Build- ing Code, Building. A. Materials: I. Metal accessories for roofs 1. Roof tile mortar shall ei- shall be not less than 26 ther be a premixed unit gage galvanized or stainless having an Product Ap- steel, 16 ounce copper, proval and tested in com- I I 0.025 in. thick aluminum, pliance with TAS 123 or lead sheet with a minimum a job site mix approved 2.5 lb/sf or equivalent non- by the building official corrosive lead metal alloys and in compliance with or composite materials manufactured for use as RAS 113. roof termination. All com- B. Mixes: ® posite and nonmetallic flashing materials shall have Product Approval. 1. Sand/cement mixes, job mixed or premixed, shall 2. Metal accessories may be of meet ASTM C 270 re-. LU a manufactured, shop fabri- quirement for Type M cited or field fabricated mortar (2.25 to 2.5:1- type, provided the materials sand to cement ratio). ww� and fasteners are in compli- LLWance with the minimum re- 2. Lightweight aggre- (� quirement of this Code and gate/cement mortar must shall be installed in compy- be premixed and bagged. ance with methods set forth in RAS 1 11. 2.06 Eave Closure —CHOOSE ONE of the following: -. 2.03 Asphaltic Adhesive: IQ A. Prefabricated EPDM synthetic A. Asphalt plastic roof cement - con- rubber conforming to ASTM D forming to ASTM D 4586, type If. 1056. nonasbestos, nonrunning, heavy body material composed of as- phalt and other mineral ingredi- B. Prefabricated metal eave closure ents. m ust contain minimum'/yin. di- ameter weepholes, spaced not more than 12 in. apart, flush with the underlayment. FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ (RAS) 120.3 (RAS) No. 120 0 C. Prefabricated concrete or clay chor/base sheet end laps shall eave closure. be a minimum of 6 in. and head laps shall be a minimum of 4 in. Over installed anchor/base D. Mortar (color optional) on granu- sheet, apply one layer of min- lar surface underlayments only. eral surfaced cap sheet ASTM D 249 in full 25 lb./sq, ± 15 per- E. Antiponding drip edge. "cent mopping of asphalt. As- phalt shall be applied uniformly so that felts do not 2.07 thing Material shall conform to touch felts. End laps shall be a APA rated sheathing, in compliance minimum of 6 in.; head laps with Chapter 23 (High -Velocity Hurri- shall be a minimum of 3 in. and cane Zones) of the Florida Building back nailed 12 in. on center Code, Building. with approved nails through tincaps. A. B� tens -material to be decay re- sist.. t species or pressure tre ed in co liance with AWP -2 or, Bette . 1. Battens hall not be bowed FIELD TILE CAPS I—®12'�� or twiste® LAP TIN CAPS ^° _—BACHNAILEDTHROUGH TM CAPS 17 a.c. 2. Vertical batte s shall be a WENDLAP � ^ WHEAD LAP minimum of no inal 1 in. x ANCHORIBASE— SNEET LAP4 .•/ 4 in., horizonta battens shall be a minimum f nom-�' inal 1 in. x 2 in. --B END LAP PART III - EXECUTION DRAWING 1- TYPICAL 30/90 HOT MAP 3.01 Underlayment Applications - CHOOSE ONE of the following: NOTE #3: The above system may be up- graded by .hot mopping an NOTE #3: Anchor/base sheet shall be a mini- interply'6f ASTM listed fiber - mum of two plies in the valleys. glass or perforated organic felt Cap -sheets for mortar set systems to the anchor'sheet before ap- shall be mineral surfaced. A No. plying the cap sheet. Asphalt 30 or No. 43 can be used as a application shall be per above dry -in prior to installing the specifications. underlayment with this system B. Hot applied Product Approved I I A Hot Mop 30/90, Hot Mop 43/1 underlayment system (see (See Drawing 1). A No. 30 or No Drawing 1). An anchor/base 43 anchor/base sheet ASTM D sheet shall be mechanically at- 226, Type 1I, or ASTM D 2626 tached to the wood deck (un- shall be mechanically attached to less directed otherwise by the wood deck with approved fas- Product Approval) with ap- teners spaced in a 12 in. grid stag- proved fasteners spaced in a 12 gered in two rows in the field, and in. grid staggered in two rows 6 in. on center at the laps. Extend in the field, and 6 in. on center anchor/base sheet a minimum of 4 at the laps. Anchor/base sheet ` in. up vertical surfaces. An end laps shall be a minimum of (RAS) 120.4 FLORIDA BUILDING CODE -TEST PROTOCOLS HVHZ (RAS) No. 120 6 in. and head laps shall be a mini- underlayment in compliance mum of 4 in. Over installed an- with the self -adhered chor/base sheet, apply one layer underlayment manufacturers' of cap sheet in a full 25# /sq. ±15 Approval/ Requirements. percent mopping of asphalt. As- phalt shall be applied uniformly E. Self -Adhered Underlayment so that felts do not touch felts. End (single ply). A single ply laps shall be a minimum of 6 in.; underlayment system utilizing head laps shall be a minimum of 3 any Product approved self -ad - in. and backnailed 12 in. on center hered underlayment. The roof through tincaps' cover is terminated at ap- proved metal flashings. Apply C. Cold applied Product approved one layer of any self -adhered underlayment system (see Draw- underlayment in compliance ing I). An anchor/base sheet shall with the underlayment manu- be mechanically attached to the facturers' approved/require- wood deck with approved fasten- ments. ers spaced in a 12 in. grid stag- gered in two rows in the field and 3.02 Drip Edge Metal - CHOOSE ONE of 6 in. on center at the laps or as the following: specified in the underlayment manufacturers Product Approval. Anchor/base sheet end laps shall NOTE #5: All exposed planes of drip be a minimum of 6 in. and head edge to receive asphalt shall be laps shall be a minimum of 4 in. primed with ASTM D 41 As - Over anchor/base sheet, apply one phalt primer. layer of cap sheet in a continuous layer of cold process adhesive at the rate of 1.5 gal/sq. or at the rate ply underlayment systems. Q I if so stated in the Product Ap- proval. Adhesive shall be applied 1. Drip edge metal shall be uniformly with a squeegee or installed overanchor/base knotted brush so that felts do not sheet, fastened4 in. on touch felts. Cap sheet side laps center with approved 1114 shall be a minimum of 6 in.; head in. roofing nails or ap- laps shall be a minimum of 3 in. proved fasten-ers. All and backnailed 12 in. on center. joints shall be lapped a minimum of 4 in. ensur- D. Product Approved Anchor/Base ing water shedding capa- S h e e t/ S e If- Adhered bilities and sealed with Underlayment system. The roof plastic roof cement. ® cover is terminated at approved metal flashings. Any approved anchor /base sheet as listed in the Product Approval shall be me- chanically attached to the wood ROOFINGEN LAPSNT,1 BEHEEEHvas deck with approved fasteners p p � ANCHOR/ BASE SHEET 1t spaced in a 12 in. grid staggered in two rows in the field and 6 in. on _ "'� \ \ o ®" center at the laps or as specified in @4c SHANK NAILS the underlayment manufacturers L4'MErAL Product Approval. Anchor/base sheet end laps shall be a minimum of 6 in. and head laps shall be a minimum of 4 in. Over anchor [base sheet, apply one layer of any Product approved, self -adhered DRAWING 2 DRIP EDGE INSTALLATION FLORIDA BUILDING CODE —TEST PROTOCOLS HVHZ (RAS) 120.5 (RAS) No. 120 B. When drip edge metal shall be in- stalled at eaves and cables over a two ply underlayment system: The metal profile shall be placed in a minimum;/16 in. bead of con- tinuous ASTM D 4586 plastic roof cement and fastened 4 in. o.c. with approved 1 1/4 in. roofing nails or approved fasteners. All bonding surfaces shall be fully primed with ASTM D 41 primer. All metal joints shall be lapped a minimum of 4 in. ensuring water shedding capabilities and sealed with approved plastic roof ce- ment. The metal profile and cap sheet shall be joined with a two ply application of cotton or fiber- glass fabric reinforcement, both set in a full bed of approved plas- tic roof cement. As an alternate, the metal may be stripped in with a 6" strip of torch, hot asphalt or cold adhesive polyester rein- forced modified bitumen. Joints shall be feathered with cold adhe- sive, hot asphalt or a torch to en- hance water flow across the "baeklap." 3.03 Valleys - CHOOSE ONE of the follow - mg• NOTE #6: All metal surfaces to receive hot asphalt shall be primed with ASTM D 41 asphalt primer. A. Preformed or roll metal without returns 16" wide shall be placed over the anchor/base sheet in the valley and shall be fastened with 12 ga. corrosion -resistant roof nails, or other approved fasteners of compatible metals near the out- side edge of the valley metal. All joints shall be water shedding and lapped a minimum of 6 in. in a bed of plastic roof cement. The cap sheet shall be bonded to the metal with asphaltic adhesive (see Drawing 3). 16' VALLEY METAL W LAP SET IN --- MASTIC & NAILED RING SHANK NAILS f`''i -SACKNAILED THROUGH TIN CAPS -MIN. 4' LAP DRAWING 3 TYPICAL VALLEY INSTALLATION B. Preformed or roll metal with- out returns 16 in. wide, shall be installed on top of the cap sheet, fully embedded in hot asphalt or plastic roof cement. All joints shall be water shed- ding and lapped a minimum of I 6 in. in a bed of plastic roof ce- ment. Strips of cap sheet, not less than 8 in. wide shall be lapped over the metal edge, not less than 4 in. and sealed with hot asphalt or plastic roof ce- ment and membrane. An op- tional #90 sweat sheet 36 in. I I wide may be applied prior to the installation of the cap sheet and valley metal. (see Drawing 4). 16• VALLEY METAL MIN. 8' STRIPS SET IN MASTIC . NAIL ENDS WITH RING SHANK NAILS OPTIONAL SWEAT SHEET MIN. SLAP • V' 'NAIL/NDS r. DRAWING 4 VALLEY METAL STRIPPED IN {iiyt'; r (RAS) 120.6 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ (RAS) No. 120 3.04 Flashing and Counter Flashings at Wall Abutments NOTE #7: In no case shall top of vertical flashing be less than 2 in. above tile surface. A. Two -Ply System - (Choose 1 or 2) (see Drawings 5, 6 and 7). l . In. tall minimum 4 in. x 5 in. metal flush to base of alls with 4 in. flange on the anchorlbase sheet and fasten within 1 in. of outside I I edge. Lap joints 4 in. ensur- ing water shedding capabil- ities and apply approved plastic roof cement between laps. Fasten the vertical and horizontal flange of metal within I in. of out side edge a minimum of 6 in. on cen- ter. The cap sheet shall be bonded to the metal with as- phaltic adhesive. -ANCHOR/BASESHEET UP VERTICAL WALL — CAULKED BEAD APPROVED FASTENERS ® S' o.a -- MIN. 4' LAP SET IN MASTIC -- APPROVEDADHESWE ' --------- COUNTER FLASHING -- -RING SHANK NAILS ® S' o.a -�— CAP SHEET DRAWING 5 WALL FLASHING DETAIL (COUNTER FLASHING WITH CAULKED BEAD) FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ ".EMSRAI SET IN MAS' NOR I BASE SHEET VERTICAL WALL AL WA L FLASHING APPROVED FASTENERS or.. MIN. a' LAP SET IN MMITIC APPROVEOADHESI' STUCCO STUCCO STOP CDUNTER FLASHING RING SHANK NAILS 4 a... CAPSHEET DRAWING 6 WALL FLASHING DETAIL (STUCCO STOP DETAIL) ANCHOR/BASE SHEET UP VERTICAL WALL j --APPROVED FASTNERS —MIN. 4' LAP SET IN MASTIC DRAWING 7 WALL FLASHING DETAIL (WALL FLASHING OVER CAP SHEET) AILS 2. Install minimum 4 in. x 5 in. "L" metal on the top ply and fastened 6 in. on center with 12 ga. corro- sion resistant roof nails, or other approved fas- teners compatible metals within 1 in. of the outside edge shall metal. All joints shall be lapped a minimum of 4 in. ensuring water shed- ding capabilities and ap- ply plastic cement (RAS) 120.7 (RAS) No. 120 between laps. Cap sheet shall be joined with a bed of plastic roof cement and a 4 in. strip of asphalt saturated cotton or fiberglass fabric. The fabric shall be fully em- bedded in the plastic roof- ing cement. 3.06 Pipes, Stacks, Vents, etc. (see Draw- ings 8 & 9). .-FLASHING SHEET TO 3. Seal along top edge within 1 EXTEND 4' BEYOND FLANGE in. of vertical flange, cover- LEAD STACK f_ ;Y APPROVED MASTIC ing all fastener penetrations with approved plastic roof FASTENERS cement and membrane. " 4. When installing optional counter flashing, lap top flange of base flashing min- imum 3 in. Fasten metal within 1 in. of the outside edge a minimum of 6 in. on center or set into reglets (se- cured properly) and thor- oughly caulk. Lap joints minimum 4 in. ensuring water shedding capabilities and apply approved plastic roof cement/sealant be- tween laps. LEAD STACK -- 3.05 Standard Curb Mounted Skylights, Chimneys, etc. (see Section 3.04 above). A. Curbs s 11 be a minimum 2 in. x 6 in., and a inimum 2 in. above up- permost add cent finished tile sur- face. B. Follow instructio s in 3.04 A o in this System. NOTE #8: For self -curbing or refabricated skylights, installatio shall meet Section 3.04B above a skylight manufacturer''s Prod ct Ap- proval. For turbines an other Product approved accessod re- fer to the accessories manut - turer's Product Approval^ DRAWING 8 NPPROVED MASTIC FASTENERS DRAWING 9 A. Apply approved plastic roof cement around base of protru- sion and on the bottom side of metal flanges sealing unit base flashing to the underlayment. B. ail all sides within 1 in. of utside edge of base flashing 6 in. on center. Make certain base is flush to deck. (RAS) 120.8 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ (RAS) No. 120 sc, NOTE #9: If pipes, vents and/or stacks are in- over fascia/starter ., ,. stalled after finished cap sheet has strip. Fasten top been applied, follow instructions edge of flange in 3.06 A & B. Cap sheet and onto roof and fas- metal flange shall be stripped in ten cave edge to with at least the same cap sheet raised fascia detail felt in use on this system. Strip- with approved fas- ping must extend at least 4 in. be- teners 4 in. on cen- yond flange in all directions. For ter. turbines and other Product ap- proved accessories refer to the Product Approval. 4. Prefabricated concrete or clay cave closure - fastened per manu- 3.07 Tile Installation: facturer's specifica- tions, such fasteners to A. Eave treatment -CHOOSE ONE be approved and sealed with plastic roof cement. of the following: 1. Prefabricated EPDM syn- NOTE #10: All fastener penetrations shall be sealed. Mortar cave closures thetic rubber -Install clo- shall only be used with granu- sure strip along cave. Fasten lar surface underlayments. each piece at 12 in. on center (see Drawing 10). 6. Mortar Application - Install 2. Metal Eave Closure - Install mortar to elevate cave edge. closure strip along cave. r'. Fasten a minimum 12 in. on (aa) Apply mortar ° center. If metal is inclusive along the cave of drip edge, fasten 4 in. edge, applying on.center (see Drawing 11). enough mortar to elevate the cave end of the tile to be 3. Raised Fascia/Wood Starter on profile with the Strip when using a s/4 in. remaining rooftile. raised fascia, a nominal 2 in. ® x 2 in. wood starter strip must be installed behind CJ fascia. (bb) oint and smooth finish flush to cave (aa) Install fascia board ap- line. LU proximately 1'/2 in. above roof deck or a ftaftj(cc) nominal 2 in. x 2 in. Applv minimum �/8 wood starter strip at in. weep hole roof edge (see Draw- flush with the roof ing 12). underlayment at spacing of not less than one weephole (bb) Install 8 in. tapered per tile. cant strip at cave be- hind fascia and/or starter strip to support NOTE #1 1: Tile shall be attached to resist metal flashing. In- the design pressures for the stall a minimum 8 in. building. See Chapter 16 wide antiponding (High -Velocity Hurricane metal flashing to en- Zones) of the Florida Building sure positive drainage Code, Building and RAS 127. FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) 120.9 (RAS) No. 120 r t See tile manufacturer's Product Approval for attachment resis- tance values, which must exceed the required calculated design pressures of the structure. FASTENER SEAL PENETRATION CAP SHEET UNDERLAYMENT MORTAR OPTIONAL CAST ANTI-PONDING METAL TILE WOOD DECK OPTIONAL WOOD STRIP FASCIA BOARD DRAWING 10 EAVE TILE DETAIL (EPDM EAVE ENCLOSURE) FASTENER SEAL PENETRATION CAP SHEET UNDERLAYMENT MORTAR METAL ENCLOSURE i.. OPTIONAL WOOD STRIP DRAWING 11 EAVE TILE DETAIL " (METAL EAVE ENCLOSURE) TILE 60 FASTENER BATTEN TILE CAP SHEET UNDERLAYMENT MORTAR PREFABRICATED EPDM WOOD DECK Ve NAIL & SEAL FASCIA BOARD PENETRATION OPTIONAL WOOD STRIP DRAWING 12 EAVE TILE DETAIL (ANTIPONDING METAL) A. Mortar/Adhesive Application: Low, High and Flat Profile Tile (see Drawings 13). 1. Set tile in a bed of ap- proved mortar/adhesive Apply 10 in. minimum f length trowel of mortal or required amount of adhesive vertically un- der pan. For flat tile place mortar/adhesive vertically adjacent to the I overlock of the tile being installed. Do not apply mortar under headlug of tile, or onto the underlock of adjacent tile. (Unless otherwise specified in adhesive's manufacturers Product Approval) 2. Use half starter/finisher tile when provided or cut/break tile for proper staggering of tile courses when using the stag- gered/cross bond method of installation. (RAS) 120.10 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ (RAS) No. 120 FILE COPY .�� /l MIN. 3/8' WEEPHOLE (ONE PER TILE) �--ELEVATE FIRSTTILE TO MATCH PROFILE B. Two -Piece Barrel Tile Mortar r'TROWEL OR or Adhesive Application (see RIADHESIVE PER Drawing # 14): CT APPROVAL /(IJ Apply 10 in. mason's trowel of mortar or re- quired amount of adhe- ONAILSPER TILE slve in accordance with the tile system Product Approval vertically over chalk line and under cen- ter of each pan with nar row end facing down roof. 2. Place bed of mortar or required amount of ad- hesive in accordance MORTAR SET TILE with the tile system Product Approval along inside edges of pans and 3. Set file in stepped course set covers with wide end fashion or in a horizontal facing down roof. and/or vertical fashion when utilizing straight bond method. 3. Point mortat to form ac- ceptable straight -edge Lay succeeding course of finish ensuring contact along edges. Cosmetic field tile in same manner. use of mortar is accept- able for use with adhe- 5. Cut break field tile to form sive set tiles. straight edge at center of hip/ridge. 4. Lay succeeding courses of field tile in same man - NOTE #12: Mortar or adhesive set the shall be ner. Bed of mortar or ad - applied at inclines of 2:12 and hesive should make greater. For pitches of 6 in.: 12 in. contact with head of up to and including 7 in.: 12 in. lower course of file and nail every third tile in every fifth underside of file being course in addition to mortar or ad- set. hesive. For pitches above 7 in.: 12 in. nail every tile in addition to 5. Cut/break field tile to mortar or adhesive. Apply ap- form straight edge at proved flashing cement to seal all center of hip/ridge. nail penetrations. Fastening re- quirements at slope of 7:12 or less for Two -Piece Barrel application 3.08 Valleys - CHOOSE ONE of the fol- applies to pan tiles only. No mor- lowing: tar or adhesive products shall be applied in a manner which pre- NOTE #13: It may be necessary to remove vents drainage of water under the lugs from the field tile at tiles, walls and valley flashings for proper positioning of cut field tiles. FLORIDA BUILDING CODE — TEST PROTOCOLS HVHZ (RAS) 120.11 (RAS) No. 120 CAP SHEET APPROVED MORTAR/ADHESIVE JX MORTAR J ADHESNE PAD MIN. W WEEPHOLES DRAWING 14 BARREL TILE INSTALLATION A. Standard Roll Valley Closed valley - Miter tile to meet at center of valley. 2. Open Valley - Chalk a line a minimum 2 in. on both sides of the valley center. Place bed of mortar along outside edge of chalk lines. Miter tile to form straight border and point to match tile sur- face. B. Preformed Metal Without Re- turns 1. Closed valley - Miter tile to form straight border on ei- ther side of water diverter. 2. Open Valley - Miter tile to form straight border on ei- ther side of two water di- verters (see Drawing 15). 3.09 Hip Starter - CHOOSE ONE of the fol- lowing: A. Prefabricated hip starter. DRAWING 15 NAIL -ON VALLEY SYSTEM VALLEY METAL OVER TILE Miter tile as hip starter to match eave lines. B. Use standard hip tiles as starter. 3.10 Hip and Ridge Installation - (` CHOOSE ONE of the following: A. Set hip and ridge tile in a con- tinuous bed of mortar, lapping tile a minimum 2 in. Ensure bed of mortar does not pro- trude in center of hip or ridge junction. Approximately 1 in. of field tile shall extend be- yond bed of mortar. OR B. Mechanically fasten hip; and ridge tiles to nailer board shall be optional on roof slopes of 2:12 to 7:12, and shall be re- quired on roof slope greater than 7:12. 1. Wood nailers shall be re- quired and attached in compliance with Chap- ter 16 (High -Velocity Hurricane Zones) of the Florida Building Code, Building. (see Drawing (RAS) 120.12 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ Y / (RAS) No. 120 16 - Details 1, 2, 3 and 4 are also accepted methods of installing Hip and Ridge Nailer Boards). 2. Wood nailer boards shall be secured with galvanized steel straps of a minimum thick- ness of I/8 in. by 1 '14 in. wide. The galvanizedsteel straps shall be installed at a maxi- mum spacing of 12 in. o.c. along the length of the ridge nailer boards. Steel straps shall be bent to fit over the ridge nailer boards, and shall be secured to the sheathing with a minimum of six #648 corrosion resistant screws per strap, at a maximum spacing of 4 in. o.c. HIP OR RIDGE TILE f 2x6 OR 2x8 HIP OR RIDGE _ NAILER PRESSURE TREATED 1/8'x 1-1/4' GALV. METAL STRAP BENT TO FIT SPACED AT 12' CENTER TO CENTER ROOF FRAMING - �, PLYWOOD ROOF SHEATHING ROOF UNDERLAYMENT -- - BARREL OR FLAT TILE - BATTENS (AS REQ'D) -- - — HIP OR RIDGE TILE NAILING DETAIL DRAWING 16 DETAIL 1 MINIMUM 212 INCH 20 GAGE x 1' STEEL STRAPS LUMBER IN ACCORDANCE WITH SPACED W o.o. FASTENED IN RAS 120 SECTION 207(A) ACCORDANCE WITH RAS 120 SECTION 3.10(B)(2) DETAIL 2 MINIMUM 2x21NCH- - WOOD NAILER SET IS A LUMBER IN ACCORDANCE WITH CONTINUOUS BED OF APPROVED RAS 120 SECTION 2.07(A) ADHESIVE DETAIL 3 26 GAGE G-90 PREFORMED METAL CHANNEL FASTENED 6' o.c. WITH APPROVED ROOFING NAILS DETAIL4 NAIL TILE IN ACCORDANCE WITH PRODUCTAPPROVAL 2.6 42 PT BLOCKING 4ti 1 12N 0'-8' 18 GAGE (VARY DEPTH OF BLOCKING TO HOT DIP DAM STEEL PLATE ACCOMMODATE PITCH OF ROOF) SET IN ROOFING CEMENT. FASTEN PLATE WITH 248 .1 1? ROOF TILE GALV PH SCREWS INTO PLYWOOD DECK 8 2-48 x 1 1M' GALV PH SCREWS INTO aG. PROVIDE @ 24' o.c. 12 14 ON EACH S1DE OF BLOCKING (STAGGER SPACING) 1 / ROOFTRUSS FILE COPY FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ (RAS) 120.13 (RAS) No. 120 .o xaeww.vawNma,ous Pro— � ' � ,,rt: sP e�neNs oPnoNri (Pnawtce '. '- 1I! •, ,?O.LLV. PN bOXflY9VAl11 OPTION. P0.W®E]JB � 1' O.V.V. PN SCOEWS WITHOUT OPTION) .- Mn-DETAIL 5 SHEET PLATE DETAIL 3.11 Rake/Gable - CHOOSE ONE of the fol lowing: A. Rake/Gable Tile: 1. Install first rake tile the ex- posed length of first course of field tile with factory fin- ish of rake tile towards the eave. �Z. J Fasten each rake tile with a. minimum of two lOD nails of sufficient length to pene- trate the framing a minimum of/q in. ' 3. Abut each succeeding rake the to the nose of the field tile above and maintain a constant headlap. B. Mortar Finish: 1. Place mortar bed along roof edge. 2. Point smooth to a straight edge finish. 3.12 Wall Abutments A. Cut tile to fit approximately'/� in. to base of walls. Fill void with mortar and point to finish. 3.13 Plumbing Stacks A. Cut tiles to fit close to plumb- ing stack. Fill void with mortar and point to finish. (RAS) 120.14 FLORIDA BUILDING CODE - TEST PROTOCOLS HVHZ r t, 2W MIAMIDADE BUELDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROI, DIVISION MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING SUITE 1603 FIL M A 33130-1563 3 ) 75 PVF(305 ) 375-2908 NOTICE OF ACCEPTANCE (NOA) Hanson Roof Tile 1340 SW 34`h Ave Deerfield Beach, FL 33442 Scopl, This NOA is being issued under the applicable rules and regulations governing the use of construction -he documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their ii­isdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade Couri:y Product Control Division that this product or material fails to meet the requirements of the cpy_ _ic; :; e wilding code. This product's approved as described herein, and has been designed to comply with the Florida Building Code including the high Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Hanson Hacienda Double Roll Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein R+ 1NE•`YAL of this NOA shall be considered after a renewal application has been filed and there has beFai no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, ands or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate thus NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. AD'VERTISEN ENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INS-1 r'TION: A copy of this entire NOA shall be provided to the user by the manufacturer or its t•�rs and shall be av; ilable for inspection at the job site at the request of the Building Official. 1. his `OA consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMI•i]ADE CAUfVTY NOA No.: 08-0204.07 Expiration Date: 04/03/13 Approval Date: 04/03/08 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tile Material: Concrete 1. SCOPE This renews a roofing system using Hanson Hacienda Roof Tile, as manufactured by Hanson Roof Tile in Sanderson, Florida and as described in Section 2 of this Notice of Acceptance. For the locations where the pressure requirements, do not exceed the values .istec in sew'_icn 4 ha 'n. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Ah lu icartt Dimensions Specifications Description Length: 17'/4" Low profile, interlocking, extruded concrete Hanson "Hacienda" Width: 13" TAS 112 roof tile equipped with two nail hole and '/i" fnictc double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Length: varies Accessory trim, concrete roof pieces for use Trim Pieces Width: varies TAS 112 at hips, rakes, ridges and valley terminations. Varying thickness Manufactured for each tile profile. 2.1 COMPONENTS OR PRODUCTS MANUFACTURED BY OTHERS Product Dizrie ss,ons Vertical Wood Battens Min. 1"x 4" ,-Iorizoritfii Min. I"x 4" for use with vertical battens or Min.:" x 2" for use atone Tile I``�.i's Kn. I Cc'x 3" Test Product Specifications Description Manufacturer Wood Preservers Salt pressure treated Generic Institute LP — 2 or decay resistant (With current NOA) lumber battens TAS114 Corrosion resistant Appendix E screw or smooth Generic shank nails (With current NOA) NOA No.: 08-0204.07 Expiration Date: 04/03/13 Approval Date: 04/03/08 Page 2 of 7 i n COPY Test Product 'Product Dimemions Specifications Description Manufacturer . #8x 21/2" long �. Corrosion resistant, Tile Screws 0.335" head dia. TAS 114 coated, square drive, Generic 0.131" shank dia. Appendix E galvanized, coarse (With current NOA) 0.175" screw thread thread wood screws dia. Clips Corrosion resistant Hurricane Clip & Min. 1/z" width , TAS 114 clips with corrosion Generic. Fasteners Min. 0.060" thick/Appendix E resistant nails. (With current NOA) Clip Fasteners Niin. &: x 1 1/a" 2.2 EVIDENCE SUBMITb"'ED Test Test Identifier Redland Technologies 7161-03 Professional Service Industries, Inc. The Center for Applied Engineering, Inc. Celo:e:: Corporation TestingServices Walker Engineering, Inc. IBA Consultants, Inc. 7161-03 7161-03 P0402 P0631-01 Letter Dated Aug. 1, 1994 224-47099 94-060B 94-084 25-7094-1 25-7094-7 25-7094-4 Project No. 307025 Test #MDC-76 25-7183-1 25-7183-2 25-7214-2 25-7214-6 528454-2-1 5?.0109-2 Calculations 2301-264 Test Name/Report PA 102 PA 102(A) PA 108 Withdrawal Resistance Testing of screw vs. smooth shank nails PA 108 PA 108 PA 112 PA 101 PA 101 PA 102 PA 102 PA 102 PA 100 PA 102 PA 102 PA 102 PA 102 PA 101 Aerodynamic Multiplier TAS 112 Date Dec. 1991 Dec. 1991 Dec. 1991 Sept. 1993 July 1994 Aug. 1994 Sept. 1994 March, 1994 May 1994 Oct. 1994 Oct. 1994 Oct. 1994 Oct. 1994 Feb. 1995 Feb. 1995 March, 1995 March, 1995 Sep.1998 Dec. 1998 March 1999 01/08/08 NOA No.: 08-0204.07 r Expiration Date: 04/03/13 MWhIFDADE COUc.�TY Approval Date: 04/03/08 a z° i� Page 3 of 7 3. LIMITATIONS 3.1 Fire classification is not -21or�mortar otlhes vi e q!RM--LQ101 a� Ve uiii 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. D.6 Phis acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. U-1STALLATION 4.1 Hanson `Haci.f!nda' Roof Tile and its components shall be installed in strict compliance with Roofing App'ic.ation Standard RAS 118, 119, & 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile profiles Weight-W (Ibf) Length-1(ft) Width-w (ft) Ha::eson Hacienda Tile 10.1 1.41 1.08 Table 2: Aerod namic Multipliers - A ft -- Tile Profile A (ft) Batten Application A (ft) Direct Deck Application _ Hanson Hacienda Tile 0.267 0.289 Table 3: Restoring Moments due to Gravi - M. ft-Ib Tile 3"• 12" 411• 12" 5"• 12" 6"• 12" 711• 12" or Profile greater Hansor: Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Hader-oa Tile Deck Deck Deck Deck Deck 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 NOA No.: 08-0204.07 Expiration Date: 04/03/13 Approval Date: 04/03/08 Page 4 of 7 Table 3: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf) L---_ -_ For Nall -On Systems T"Pe jFastener Type Direct Deck Direct Deck Battens Profile (Min 15/32" plywood) (Min. 19/32" plywood) Hanson 2-10d Ring Shank Nails 27.8 37.4 28.8 Hacienda Tile 1-10d Smooth or Screw 8.8 11.8 4.1 Shank Nail r' 2-10d Smooth or Screw Shank Nails 16.4 �/ 21.9 7.1 1 98 Screw r26.8 25.8 22.9 2 48 Screw / 47.1 47.1 49.1 1-10d Smooth or Screw / 24.3 24.3 24.2 Shank Nail Field Clipy j�1.•10d Smooth or crew Shank Nail (Save Clip) 19.0 19.0 22.1 2-10d Smooth or Screw 7ha kltiails (Field Cli 35:5 35.5 34.8 Smooth or ^crew an Na. s are Cli 31.9 31.9 32.2 2-10d rTr � Sha_,i,: Nails 43.0 67.5 50.9 j 1 Installation with a 4" tiie headlap and fasteners are located a min. of 2%2" from head of tile. ''able 4: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) For Two Patty Adhesive Set Systems Tile The Application Minimum Attachment _ Profile - Resistance Hanson Hacierza Tile Adhesive 26.1 2 See manufactures cc.rnpurlant approval for installation requirements. 3 Flexible Products Company Tiip6cnd Average weight per patty 11.4 grams. Pol)oar.L Product, lrr:. ;Avara ia r.ei ht er a 8 rams. FILE -COPY NOA No.: 08-0204.07 Expiration Date: 04/03/13 Approval Date: 04/03/08 Page 5 of 7 IN Table 4A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) _ For Single Patty Adhesive Set Systems Tile Application Minimum Attachment _ _ Prof;le Resistance Polyfoarn Pol ProTM 86.61 Hanson Hacienda Tile Polyfoarn Pol ProTM 45.5 4 Large paddy placerneni—of 54 rams of Pol Pro'rm. 5 Medium paddy placement or 24 rams of Pol ProT"' Table 413: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) For Mortar Set Systems Tile Tile Attachment Prorile Hanson Flaci;mcla Ti Mortar $. LABELING Ail 'Ziles sha:-bear 11s ,,,priat or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved". sJ31DVH HA:NSON HACIENDA ROOF TILE T"T �.;" UF? -ATION MARK (LOCATED ON UNDERSIDE OF TILE) 6. ,UIIL}= NG PE7 V F: REQL'IR.EWNTS b,1 .�ppiii auon for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.i A nw other documents required by the Building Official or applicable .. . ~ g code in order to properly evaluate the installation of this system. FILE COPY NOA No.: 08-0204.07 "MCOUEPT7171111, Expiration Date: 04/03/13 M"I. Approval Date: 04/03/08 Page 6 of 7 PROFILE DRAWINGS HANSOM HACIENDA CONCRETE ROOF TILE V A Q 9r WFV T-D Y 7 di -c V., 0 UNDI RLOCK END.O.FITHIS.-ACCEPTANCE FILE COPY NOA No.: 08-0204.07 ffimlffm,w�, Dip Expiration Date: 04103/13 Approval Date: 04/03/08 Page 7 of 7 44, l t�4 I A M FDAD BUILDING CODE COMPLIANCE OFFICE (BCCU) PRODUCT CONTROL DWISION 1iIAMI-DADE COUNTY, FLORIDA ME:TRO•DADii FLAGLER BUILD)\G 140 WEST FLAGLER STREET. SUITF. 1003 MIAMI, FLORIDA 33130-1303 (305) �75-2901 FAX (305) 375-2903 NOTICE OF ACCEPTANCE (NOA) _ Bermuda Roof Co., Inc. 1499 W. Palmetto Park Road, Suite 169 Boca Raton, FL 33486 SCOPE: This NOA is tieing issued under the applicable rules and regulations govelping the use of construction materials. Tho documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid alter the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miatni Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense ol'such testing and the MU may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Nlianii-Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Binh Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Lightweight Roof Tile'Mortar LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL!. of this NOA shall be considered after a renewal application has been tiled and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or i f there has been a revision or change in the materials, use, and/or manufacture of the product or process. (Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISE&LENT: The NOA number preceded by the words Mianii-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available 11or inspection at the job site at the request of the Building Official. This NOA renews NOA No. 01-0130.09 and consists of pages 1 through 6. The submitted documentation was reviewed by Jor e L. \echo. �"^��T NOA No.: 06-0329.Oi Expiration Date: 09/20/11 R_. - approval Date: 07/20/06 Page 1 of 6 ROOFING CON'IPONEN'r APPROVAL: FILE Co Category. Roofing PY Sub-C:atcbory. Roof Tile Adhesives Material: Cement Deck '!'vue: Wood Maximum Design Pressure N/A SCOPE: This renews "File -rite" Roof 'file Mortar, as manufactured by Bernntda Roof Company, Inc. as described in this Notice of Acceptance, and designed to comply with the High Velocity llurricane Lone of the Florida Building Code. PRODUCT DESCRIPTION: Manufactured by_Applicant DProduct imensions Description Premixed prebagged roof tile mortar for used with `Tt7eTite"TtoofTieaF�ortar> N/A approved roof tile in accordance with RAS 120 LIMITATIONS: I. fire classification is not part of this acceptance. 2. Field uplift. testing shall be perfomied, in compliance with the test procedure set forth in RAS 106. Testing shall be perfornied not prior to 30 days after installation. 3. "Tile -Tito" Roof Tile Mortar shall he placed in accordance with the 'Placcment Details' provided herein. Bach generic the profile requires a specific placement. (sec placement Deiail listed herein). 4. "Tile -rite' Roof Tile N-lortar shall be applied in accordance with Bermuda Roof Specifications. i. Tile must be applied within .i minutes of the application of "Tile -rite' Roof Tile ]Mortar. 6. Refer to RAS 120, for penetrations and terminations, as well as the Tlacement Dctails' herein. 7. Refer to Tilc manufacturer's Product Control Notice ofAccep►ance for system approvals. INSTALLATION: I, "file-Tite Roof 'file Mortar and its components shall be installed in strict compliance with RAS 120. 2. Placement Details Adhesive Placement: GENERIC PLACEMENT PROFILE: DETAIL. # Two piece Barrel A Spanish & Mission B Low Profile Roll C Flat p I,AB EILING: All bags shall be labeled in accordance, with the Standard Conditions herein. _ ' NOA No.: 06-0329.U5 Expiration Date: 09/20/11 G + Approval Date: U720i06 Page 2 of 6 FILE COPY BUILDING PERMIT REQUIREMENTS: Any documents required by the Building Official or applicable building code in order to properly evaluate file installation of' this System. EVIDENCES SUBMITTED: 'Pest Agency "Pest Identifier Test Name/Report Date Center for Applied #94-084 TAS 101 04/08/94 Engineering, Inc. Florida Testing and #450225 ASTNI C9 05/10/94 Engineering, Inc. Type NI PRlAsphalt 'Iechnoloeies BRCI-001-02-01 TAS 123,?AS I01 03/14/06 PLACEMEN'I' DETAIL "A" TILE & MORTAR PLACEMENT - BARREL TILE - 2 PC. PAN h10RT.Alt Bl FOR COIVEF FASCIA BOARD ON EDGE REQUIRED 200F PITCHFS) T P:1N HERE rDl'rIONAL MQUIRED BY CODE) NAIL COVER HERE (\M71F_N REQUIRED) NY1iEE1'110LF// POIYI'-UP ::]!91K METAL EA VE DRIP moit,r.AR BED NOA No.: 06-0329.05 Expiration Date: 09/20/11 n Approval Date: 07/20/06 Page 3 of 6 n / � FASCIA BOARD PLACEMENT DETAIL,FILE 90 # iyIINERAL SURI+ACE ROOFING FELT 10" MASON TROWEL FULL OF MORTAR NAILTHROUGH PLASTIC ROOF CEMENT (WIZEN ADDITIONAL NAILING IS REQUIRED BY CODE BARGE BOARD ' ,NOA No.: 06-0329.05 y Expiration Date: 09/20/11 Approval Date: 07/20/06 ` Page 4 of 6 r � � 1 PLACEMENT DETAIL " ." COPY 90 # iiMINER L SURFACE ROOFING FELT NAIL. THROUGH PLASTIC ROOF CEMENT (WHEN 10" MASONTROWEL ADDITIONAL, NAILING IS FULL OF -MORTAR J I REQUIRED BY CODE 1 I In / O SECURE WITH CORROSION FASCIA 12ESISTANCE NAILS / BOARD BARGE BOARD 1d'ILEI;PIIOL,E � POINT -UP WITH COLORED VIORTAR TO KLATCH TILE, (EPON) PRE-FARRICATEI SURFACE CLOSURE NAILED'rIIROUGH ROLLED RAKE TILE PLASTIC ROOF CEMENT OR (SPANISH 'IS" CUTS) INTO APPROVED ADHESIVE SURFACE NOA No.: 06-0329.05 Expiration Date: 09/20/11 4 Approval Date: 07/20/06 Page 5 of 6 PLACEMEV7' DETAIL "®" TOTE: MORTAR SHALL NOT REACH INTO THE HEAD OF TILE, IN PREVIOUS COURSE OR INTO UNDERLOCK OF ADJACENT "TILE. 10" MASON TROWEL FULL OF MORTAR ILEADLAP �IETA-1. EAVE DRIP FASCIA BOA THICKBUT TILE. I . 1'IIE BEAD OF ONE TILE 2. THE UNDERLOCK SIDE OF I A SECOND TILE 3. THE UNDERSIDE OF THE PILE BEING SET NAIL, IIERE THROUGH 1PLASTIC ROOF CENIF.NT (WHEN REQUIRED BY CODE) �� •t t we S END OF THIS ACCEPTANCE FILE COPY NOA No.: 06-0329.05 Expiration Date: 09/20/11 ` Approval Date: 07/20/06 Page 6 of 6 i MIAMI-DILE ADE COUNTY, WMA METRO -DADS FLAGLER BUILDING MIAMNDIADE BUMDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORMA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AM may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the South Florida Building Code,1994 Edition for Miami -Dade County or Florida Building Code. DESCRIPTION: Polyset ® One Roof Tile Adhesive RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 5. The submitted documentation was reviewed by Mark A. Zehnal, CPRC NOA No.: 04-1116.01 Expiration Date: 08/24/10 Approval Date: 08/24/05 Page 1 of 5 ROOFING ASSEMBLY APPROVAL: Category: Roofing Sub Category: 07320 Roof tile adhesive Materials: Polyurethane FILE COPY - I- SCOPE - -- - -- - — - - - This approves Polyset @ One as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code, Edition for Miami -Dade County. For the locations where the pressure requirements, as determined by applicable building code, do not exceed the design pressure values; as obtained by calculations in compliance with RAS 127, using Polyset @ One, and where the attachment calculations shall be done as an moment based system. 2. PRODUCT. DESCRIPTION Manufactured by Applicant Dimensions Polyset One Factory premixed canisters Product Description Single component polyurethane foam roof tile adhesive 2.1 Components or products manufactured by others: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polyset @ One roof file adhesive. 2.2 Typical Physical Properties: Proa Test Results Density ASTM D 1622 1.95 lbsJft.30 Compressive Strength ASTM D 1621 7.8 psi Tensile Strength ASTM D 1623 19.95 PSI Parallel to rise❑ Water Absorption ASTM-D 2842 4.22 Lbs./Fell Moisture Vapor Transmission❑ ASTM E 96 3.5 Perm / Inch Dimensional Stability ASTM D 2126 +0.89% Volume Change @ 70' C., 2 weeks Closed Cell Content ASTM D 2856 72.14%11 3. LDWATIONS 3.1 Fire classification is not part of this acceptance. 3.2 Polyset @ One can be used with flat, low, high file profiles. 3.3 Minimum-underlaymentshall be in compliance with the Roofing Application Standard RAS 120. 3.4 Roof Tile manufactures acquiring acceptance for the use of Polyset @ One roof tile adhesive with their tile assemblies shall test in accordance with RAS 101 with section 10.4 as modified herein. 3.5 F _ w P-- 2 MS NOA No.: 04-1116.01 Expiration Date: 08/24/10- Approval Date: 08/24/05 Page 2 of 5 4. INSTALLATION 4.1 Polyset One may be used with any roof tile assembly having a current NOA that lists moment resistance values with the use of Polyset ® One 4.2 Polyset ® One shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive -- - -- - - - -- - ---- - -- - -attachment with-the-use-of-Polyset-O-One-shall-provide.sufficientattachmentresistance,- expressed as an moment based system, to meet or exceed the moment resistance determined in compliance with Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 4.3 Polyset ® One roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polyset One Operating Instruction and Maintenance Booklet 4A Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. 4.5 Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after Polyset ® One has been dispensed. Polyset ® One placement shall be in accordance with the'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Typical Placement Detail Weight per paddy Flat, Low & High Profile # 1 6.5 High Profile 2-Piece Barrel # 2 8.7 5. LABELING 5.1 All Polyset ® One containers shall comply with the Standard Conditions listed herein. 6. BUILDING PERMIT REQUIREMENTS 6.1 As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. FILE COPY NOA No.: 04-1116.01 Y Expiration Date: 08/24/10 Approval Date: 08/24/05 Page 3 of 5 Adhesive Placement Details riL COPY NOA No.: 04-1116.01 Expiration Date: 08/24/10 Approval Date: 08/24/05 Page 4 of 5 ADimswE PLACEMENT DETAILS (CONTnwED) PLACEMENT DETAIL # 2 END OF THIS ACCEPTANCE FILE C-OPY NOA No.: 04-1116.01 Expiration Date: 08/24/10 Approval Date: 08/24/05 Page 5 of 5 t / TAMKO® MOe30 ASTM RODUCT DATA t Saturated Organic Felt Manufacfured in Green Cove Spmngs, FL., TAMKO® NO.. 30 ASTM SATURATED FELT features a premium quality TAMKO organic felt (non -perforated) that is saturated with asphalt. Accepted for use as an underlayment felt to be applied over the deck prior to the installation of TAMKO asphalt shingles. Underwriters Laboratories Prepared Roofing Accessory ASTM D 226, Type If Roll Dimensions 72' X 36" Coverage per roll 2 Squares Laying Lines 2", 4", 17" 'All values stated as nominal FILE COPY CAUTION: The National Institute for Occupational Safety and Health (NIOSH) has concluded that fumes of heated asphalt are a potential occupational carcinogen. Do not heat or bum this product. j I�mI�V' Visit our Web Site at www.tamko.com ROOFING PRODUCTS Central District Northeast District 220 West4th St., Joplin, MO 64801 ozrzooa 800-641-4691 TAMKO Logo, Roofer Logo, andTAMKcr Southeast District 4500 Tamko Dr., Frederick, MD 2300 35th St., Tuscaloosa, AL 21701 800-368-2656 are registered trademarks of TAMKO* Roofing products, Inc. Southwest District Western District 7910 S. Central EX ., Dallas, TX p 35216 800-228-1834 800-530-1868 5300 East 43rd Ave., Denver, CO 80216 80216 800-530-8868 M 1 A M I-DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) 1 PRODUCT CONTROL DIVISION MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) CeriainTeed Corporation (PA) 1400 Union Meeting Road, P.O. Box 1100 ��� % Blue Bell, PA 19422 SCOPE: This NOA iG being issued under the applicable rules and regulations governing the use of construction materials. '-'-'.le documentation submitted has been reviewed by the 13CCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the Nigh Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this N-OA will occur after the expiration date or if there has been a revision or change in ide'niaterials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayer:, then it shall be done in its entirety. INSPEC'11ON: A copy of this entire NOA shall be provided to the user by the manufacturer or its distribuwrs and shall be available for inspection at the job site at the request of the Building Official. This NOA renevis NOA No. 03-0827.02 and consists of pages 1 through 39. The subntted documentation was reviewed by Jorge L. Acebo. NOA No.: 08-0227.09 MIAMbDACEcou�n Expiration Date: 06/19/13 ... � Approval Date: 05/15/08 Page 1 of 39 ROOFING AsSEMBLV APPROVAL y Category-, Roofing Sub -Category: APP/SBS Modified Bitumen Deck Type: Wood Maximum Design Pressure -60 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1. Test Product odu Dimensions Specification Description tl I11k2ther it36" x 7T, Roll ASTM D 2626 UL Asphalt coated organic base sheet. weight: 86 lbs. Type 15 (2 squares) Flex-I-GlasTM Base 36" x 108', Roll UL Type G2 Modified Bitumen coated fiberglass base Sheet weight: 90 lbs. ASTM D 4601, sheet. (3 squares) type H Flex-I-GlasTM FR Base 39 318" x 50', Roll UL Type G2 Modified Bitumen coated fiberglass base Sheet weight: 90 lbs. ASTM D 4601, sheet. (1.5 squares) type II Flintglas® Ply Sheet 36" x 1-80', Roll ASTM D 2178 Fiberglass, asphalt impregnated ply sheet. Type IV or V1 weigr .: 40!55 lbs. Type IV or VI (5 squares) UL Type G1 Flintlastic STA 39 3/s" x 33', Roll ASTM D 6222, Smooth surfaced APP Modified Bitumen STA Plus 5.0 weight: 90 lbs. Grade S, Type II membrane with non -woven polyester mat (1 square) reinforcement for torch application. Flintlastic GTA, GTA- 39 3/g" x 33' 3", Roll ASTM D 6222, Granule surfaced APP Modified Bitumen FR or Flintlastic weight: 105 lbs. Grade G, type II membrane with non -woven polyester mat Diamond GTA (1 square) reinforcement for toch application. Flintlastic GTS 39 3/g" x 249", Roll ASTM D 6164, Granule surfaced SBS Modified Bitumen weight: 92 lbs. Grade G, Type II membrane with non -woven polyester mat (3 square-) reinforcement for torch application. Flintlastic G-A,!S, 39 3/8 .' x 34 2", Roll ASTM D 6164, Granule surfaced SBS Modified Bitumen Premium GMS weight: 100i 105 lbs. Grade G, Type H membrane with non -woven polyester mat (1 square) reinforcement for mop application. Flintlastic FR-P, 39 3/8" x 34` 2", Roll ASTM D 6164, Fire resistant, granule surfaced SBS Premium FR-P weight: 105 lbs. Grade G, Type I Modified Bitumen Membrane with non- (1 square) woven polyester mat reinforcement for mop application. Flintlastic FR Cap 39 3/R" x 34' 2", Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 90 lbs. Grade G, Type I Modified Bitumen membrane with (1 squaael/ fiberglass mat reinforcement for mop applications. Flexiglas Premium Cap 36" x 3C ASTM D 6163, Granule surfaced SBS Modified Bitumen 960 (1 square) Grade G, Type I membrane with fiberglass, mat reinforcement for mop application. NOA No.: 08-0227.09 MMIAMIODADECOTFILE COPY Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 2 of 39 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) L 412 & #la Dekfast Insulation fastener Construction Fasteners, Inc. Fastener 2. Dekfast Hex Plate Galvalume AZ50 steel plate 2 7/8" x 3 I/a" Construction Fasteners, Inc. 3. Olympic. Fastener #12-�Insulation fastener Olympic Manufacturing & 414 Group, Inc. 4. Olympic Standard 3" round galvalume AZ50 3" round Olympic Manufacturing steel plate Group, Inc. 5. insul-Fixx Fastener Insulation fastener for steel SFS Stadler, Inc. and wood decks 6. Insul-Fixx S Plate Galvalume AZ50 steel plate 3" round SFS Stadler, Inc. 7. Tru-Fast Fasteners Insulation fastener for wood The Tru-Fast Corp. and steel decks 8. Tru-Fast MP-3 Galvalume AZ50 steel plate 3" round The Tru-Fast Corp. 9. Tru-]�ast Plates Galvalume AZ55 steel plate 3" round The Tru-Fast Corp. 10. Tru Fast Plates Polyethylene plastic plate 3" round The Tru-Fast Corp. EvIDENCE SUBMITTED: Test Agency Name Reuort Date Applied Research Laboratories Physical Properties 28013 06/02/87 Factory Mutual .Research Current Insulation Fastening FMRC 1994 01/01/95 Corporation Requirements Factory Mutual. Research PA 114 J.I. #3Y8A1.AM 03/23/96 Corporation (FMRC 4470) Jnderwriters Labo.:_atories, Inc. Fire Classification R11656 07/13/87 Compliance United States Testing Company, ASTM D 5147 97457-4 06/03/88 Exterior Research & Design, LLC TAS 114 (J) #3507.08.99-1 04/18/01 Exterior Research & Design, LLC #3514.02LAB 11/11/02 Exterior 1?e ear-, & Design,, LLC TAS 114 #3515.07.03 07/22/03 TAS 117 FILE COPY NOA No.: 08-0227.09 r Expiration Date: 06/19/13 MIAP+ I- �D - COUPfrf Approval Date: 05/15/08 Page 4 of 39 ;, Membrane Type: 6 Deck Type 1: APP MODIFIED Wood, Non -insulated Deck Description: Minimum 19/32" thick plywood attached using wood screws spaced 6"o.c. at wood joists spaced maximum 24" o.c. System Type E(;): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glas Base, Flex -I Glas Base, Flex-1 Glas FR Base or All Weather / Empi; a Ease ' hae__ t mechanically fastened as detailed bel_ low. Fastening: Base sheet shall be lapped 4" and fastened with Simplex Mega Cap Nails spaced 9"o.c. in the lap and 9" o.c. in two staggered rows in the center of the sheet. Ply Sheet: ((Optional One ply of GlasBase, Flex-I-GlasBase, Flex-I-Glas FR Base, PolySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Flintlastic STA, Flintlastic Diamond GTA, Flintlastic GTA or GTA-FR torch adhered to base or ply shee Surfacing: (Optional) Install one of the following: 1. 400-lb./sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak 97, FlintCoat A-150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 1/z gal. /sq. Maximum Design Pressure: -60psf. (See Czeneral Limitation #7) FILE COPY MEL NOA No.: 08-0227.09 MIAMI-DADE COU1VTY Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 37 of 39 l WOOD DECK SYSTEM LIMI`.CATIONS: " 1. A slip sheet is required wish Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL U-miTATIONSa 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' r. 4` maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a corrtiiatious area of ventilation. 'Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a ardninium rate of 12. lbs.isq. Note. Spot attached systerths shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for in.3111aticla attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 l'of. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a mu irriurn fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Prol�sioiaal Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said ra+i isad fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Puri-rieter and com'zx areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener dt rnsldr;% slAdll be increased for both insulation and base sheet as calculated in compliance with Roof-.iig Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered 'Professional Engineer, Registered Architect, or Registered Roof Consultant \�YL.en thts l unitaflon is specifically referred within this NOA, General Limitation #9 will not be applicable;.) 8. All attacliant:nt and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall co_} crm to Roofing Application Standard RAS 111 and applicable wind load requirements. The :aia.K.L aurn designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. �J fie i,i, perimeters, and c.:rners). XIeither rational analysis, nor extrapolation shall be permitted for eriiaar_ced fastening at aMiiceci i,ressure zones (i.e. perimeters, extended corners and corners). (4,"Viie;n this liinitamiiFout ;; spec Oizally referred within this NOA, General Limitation #7 will not be applicable.) 10. All l.r::}chwc s iisted Lxeie ,hall_ have a quality assurance audit in accordance with the Florida Building Code and Rule S5-72 of :he rloLida Adnunistrative Code. END Off` THIS ACCEPTANCE r;I� NLlil tF Cop NOA No.: 08-0227.09 rp1pr ation Date: 06/19/13 ,;t'•y�(; ;. o II`; rovai Date: 05/15/08 Page 39 of 39