Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDATE FILED: PLAN REVIEW FE : RECEIPT NO.: PERMIT NUMBER: CONCURRENCY FEE: RECEIPT NO.: CERT. CAP. NO.: ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED St. Lucie County Building and -Zoning anyzal 2300 Virginia Avenue . cc) Ft. Pierce, FL 34982-5652 S 772-462-1553 �����® St. Luc'O County APPLICATION for BUILDING PERMIT CERTIFICATE of CAPACITY/ZONING COMPLIANCE PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: -5700 swh s& NN • �t- 2. S/D NAME: hIC r SITE PLAN NAME: ! �t tl 3. PROPERTY TAX ID #: 3 4 4. LEGAL DESCRIPTION (attach extra sheets if necessary): 7tjt,4&, MP 5. PLAT 6. PAGE BOOK NO. BLOCK r 8. LOT yp NO. b NO. 9. PARCEL SIZE: ACRES/SQ Fr. �. LOT DIMENSIONS 10. DESCRIPTION OF CONSTRUCTION PROJECTOR WORK ACTIVITY: Ad AQ Lv%nj T F AcC/d/,N_nc1 e 11. SETBACKS (ACTUAL) FRONT: a S BACK: 2 . c7 12. TYPE OF CONSTRUCTION (Check all appropriate boxes) NEW CONSTRUCTION RESIDENTIAL OTHER (SPECIFY) _ RIGHT: u SIDE J 7 i3$ LEFT: SIDE l EXPANSION/ADDITION [ ] INTERIOR RENOVATION [ ] COMMERCIAL [ ] INDUSTRIAL 13. DESCRIPTION OF PROPOSED USE: Tor --mot L-• vI 14. Sq. Ft./CONSTRUCTION: 15. Sq. Ft. 1st Floor 16. VALUE OF CONSTRUCTION: $ ?q ®. E; g �✓a The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more,•a RECORDED Notice of Commencement must be submitted with this application. SLCCDV Form No.: 001-02 OWNER INFORMATION NAME: ADDRE: r CITY: �- �� arcs STATE: P-1 ZIP 5 4 -7.6 d� _ r�r PHONE (DAYTRvIE): (-) �6 - z/ email: IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE, PLEASE FILL IN NAME -AND ADDRESS BELOW. FEE SIMPLE TITLEHOLDER: S It ADDRESS: CITY: PHONE (DAYTIIv1E): STATE: CONTRACTOR INFORMATION ST. of FL REG./CERT #: C 6, Lt S ST. LUCIE COUNTY CERT #: + �� BUSINESS NAME: P wL N—u`5 QUALIFIERS NAME: C OPr( ADDRESS: 15 50 5 E ',.f(jLA esr' ST' CITY: P61 si%�` LL. STATE: � C . ',ZIP PHONE (DAYTIME): �) � O �-o aG FAX NO.i-)g k 6 'email: ARCHIT/ENGINEER: i�GS Fn tnc�r� ��®� I L ADDRESS: LI�J 4 �/ L���e nwc k STATE:L ZIP CITY: .. , PHONE (DAYTIME): 0i) BONDING COMPANY: ADDRESS: CITY: MORTGAGE LENDER: ADDRESS: _ _. CITY STATE: STATE: ZIP ZIP IMPORTANT NOTICE: When a permit is issued and it is not picked up within 60 days after notification it will be voided and returned to you by mail. CERTIFICATION: This application is hereby made to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if -applicable, for the permitted work. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AND AIR CONDITIONERS, ETC., not otherwise included with this building permit application. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures (all types), swimming pools, fences, walls, signs, screen rooms, utility substations & accessory uses to another non- residential use. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: AS THE APPLICANT FOR THIS BUILDING PERMIT, IF IT IS NOT YOUR RIGHT, TITLE, AND INTEREST THAT IS SUBJECT TO ATTACHMENT; AS A CONDITION OF THIS PERMIT YOU PROMISE IN GOOD FAITH TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT. OWNER'S AFFIDAVITr �� I certify that all the foregoing information is accurate and�ork will be done in compliance �)with all applicable laws regulating construction and zoni g. z n SI STATE OF FLORIPA COUNTY OF The foregoing instrument was acknowledged be ,ore me thus is day of �_, 20 4, by /V`✓m)cud7(nre,.:.y , who is P- , 35 known to me or who has produced �ia- as identification. A. Type or Print Nam STATE OF FLORIDA COUNTY OF Sf- �aaE The foregoing instrument was acknowledged before m this % day of, 206, by who is pe known to me r who has produced NIP r— as identification. Si_na r/�/�t1�4e/er��%� /`�/ /y dish Type or Print Name of Notary Notary Public State of Florida Commission No. _ ( ��T,homas Moore Co isi Puhlir State '�iy (, mmission DD474179 Karl Thomas Moore 71 OF a Expires 09I2112009 My Commission DD474179 NOTE: TWO (2) SIGNATURES ARE REQUIRED - SIGNATURE M �o�ti� � : 1r2 NG FOR THIS BUILING PERMIT AS AN OWNERIBUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON THE FRONT OF THE APPLICATION. For specific instructions see appropriate permit checklist. I .OFF CE USE: ONLY SECTION TOWNSHIP /„ RANGE ® MAP NO. 3 I % ZONING R LAND USE LOT CVG % 0 1 TAZ NO. FLOOD ZONE AM� FIRM MAP # j 1s'r FLR ELV MAX HGT CONST TYPE OCCUP TYPE MAX OCCUP # OF FLRS WATER SEWER it SPRINKLERS STORMWATER LOT OF REC LOT OF REC (after LOT SPLIT LOT SPLIT (before 1/90) 1/90) REQUIRED _ -.. , i t a ADMINST LIBRARY PARKS PERMIT FEE VARIANCE IMPACT FEE IMPACT FEE REPORT PUBLIC BLD HABITABLE RADON FEE CODE IMPACT FEE AREA �� (RADON) SCHOOL GROSS ROAD CREDI Y N TOTAL ROAD IMPACT FEE IMPACT FEE IMPACT FEE DUE z SCHOOL CREDIT Y N TOTAL IMPACT FEE z SCHOOL IMPACT FEE POLICE FEE F EE MISC FEE TOTAL POLICE/FIRE MISC FEES ADDITIONAL Y N ,'-_- SPECIFY TOTAL of ALL --= — - - PERMITS FEES REQ D 5 .77 REVIEWS ZONING ZONING PLANS MISC. VEGETATION SEA TURTLE MANGROVE REVIEWED BY EXAMING DATE � /1 /�9 D COMPLETE r 6 (/ 6 v INITIALS Nov 21 2006 11 :27AM HP- 'RSERJET FAX _ � P- 1 St Lucie county'L3T=dons 41`1 0.1 CERTIMCATE OF TERMITE TREATAWISM CONSTItUCUON SOIL TRF,.ATMENT PERWT#, U8070253 jOR,DOg=S 5900 Sunset Blvd, Ft Pierce, FL gUp,O��.Tose Linn Services - - — PEST CONTROL COAI'j�tyTOR_ �g�ick 8xterminating, Inc. PEST CONTROL LICENSE # '416 4 We, the snndcrtiVmd, hwebr certify that we b2v4 pretreated the above -described consMWthm for mbtiarranaaccordance with the stacdn-da of the NadmW P"t Control Assadfe %*& Sguam. feei at area trewbed: 600 perreatage or niboo": , - % bsU of trewUwnt: -_ 1112110 S 0 Footang . Q iaT Treatment . ❑ Fwat C1 Slab Q ist Tmatment 0 Re-Irea Q Driveway Q• 1st ❑' Ra-iYeSt D Pools Q wTRSt =t C;hwWMk : Prpbu i ld TC Total gaWms tined: 3 0 Time of Treatment 9.0 0 FEC104.0 Cuircate of AraftcrOc7?ewmextfarpn"A&m of lermflet. A +r abor ►es s&w fahsfte pwfMg kord,hail be pmvioW to mire djWU0 "TremmensCsrt=sts drCWh -4Uhsd pmWane rfC&A- nt it tatnputsd, prove ks a copBfora+r penwA the psrrnit is Laawd to ani arrrt>tsregpy�rt tha 6rr+fdirrg pe►sift file9 ThaTioam ow C:MtcM $half prov$ds the pAwW: wed, idwW of rhs applicator, 6w may dine of the pwbrant. ties location, area ireate4 chemical turd, ptmnt eaxcennerrion sasdrsmmber afgafloustccsrd, to establish a veriflable record ofp►-arearive trraa mr. if the tail ehmkal baroUr mahee far s rnctrs prevowUx itused, final eaarior mahesar $hall U campieradprior ro final huUAna apprmL St Ic3e County requL +es ftw flee 2=1 lnspeeftsn fsr CO, s Pa'taaaent 60C3 W to be placed an ttsa glectrkd pwd boar sore,,. llsriog &Z for treatawnts =a dices arappikaucm- Q- Re -treat Q 0d= 0 istTwatment Q Re -treat f� Perimeter for Final 3nspw ion IMM&N Or: jok A-t NET., TAwrfe most be a compktod fern: far rash required trteett sms or re-Weaftent and this form mum be on the, fob site to bepicked up by the Wperiorat-time of each faWecpon or the sel ,Awed saspeaft wQ faeietrtd a re-iuipactlo7i fsi chardea: �ifi�iisda/llN3�pt 6'd V9-VZ0b£ZLL u01}eao}Se�1 Sinew fined dbZ:60 80 �Z AON November 17, 2008 Saint Lucie Building Department, I trust that Paul Davis Co. will complete the sink area in the bathroom of the addition they built on our home. Homeowner: Maryon Thiery ,It Jun-14-2002 01:05am From -SAVANNA CLUB 45618785655 T-468 P.001/001 F-T61 St Lucie County Inspections 2300 Virginia Avenue Ft Pierce, FL 34982 (772) 462.2172 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOII. TREATMENT PERMIT JOB ADDRESS BUILDER �O� PEST CONTROL PEST CONTROL LICENSE # ��Co We, the undersigned, hereby certify that we have pretreated the above -described construction for subterranean termites in accordance with the standards of the National Pest jControl Association. Square feet of area treated: 3 (9,! Chemicals used: Percentage of solution: ' 2.5- Date of treatment: /`- 7 - 0 Q Footing ❑ 1st Treatment ❑ Re -treat ❑ Slab ❑ 1st Treatment ❑ Re -treat Driveway ❑ 1st Treatment ® Re -treat ❑ Poo1S ❑ lst Treatment Total gallons used: Time of Treatment: /J V FBC104.2.6 Cettficate of protective 7rearment for prevention of termites. A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required prorecrive rreatmetu is completed, providing a copy for the person rho permit is issued to and another copy for the building permit files. The Treatment C'erttticate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area created, chemical used, percent concentration and number of gallons used, to establish a verifiable record of prorecrive treaftnetir. If the soil Chemical barrier tnerhod for termite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. ❑ Re -treat t - Other 9.+c1Z vaaty, LLe!� Ro,_�_ b4st Treatmi nt Q Re -treat . 0 Perimeter for Final Inspection pazc� Signature of exterminator NOTE: There must be a completed form for each required treatment or re -Treatment and this for n must be ort the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will Revise,rt 6/!3/03 fail and a re -inspection fee charged. dmP 0 7 % / /% - �7 �JL�6 CMG ST. LUCIE COUNTY •.; BUILDING $ ZONING -r 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-55652 F�ORIOP 462-1553 FILLED LANDS AFFIDAVIT I, the undersigned, am the owner of the following described property: 0a - bay - oL19 ) , aces - a for which I have applied to St. Lucie County for a Final Development Permit. In accepting this Final Development Permit, BP Number (W0)-6�S3 , I acknowledge that as owner of the above described property, and in accordance with Section 7.04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this property, St. Lucie County -is neither obliged nor liable to provide for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. iAA le(t" Property Owner Name Property Owner Signature Date STATE OF FLORIDA. COUNTY OF C ]i . ,P1? , ACKNOWLEDGED BEFORE ME THIS U= DAY OF /' , 26' , BYIt-At u J WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED -T -- AS IDENTIFICATION. fG-N=R*E �NO TYPE OR PRINT NAME OF NOTARY NOTARY PUBLIC TITLEtAILMO (PCOMMISSION NUMBER (SEAL) JAIMEL.?AVALA N01IFY Public - Stay of Floft !MY Commipioq EyMa liar 1a, p010 Commission 11106 614666 FEDE1 1798 AGORA CIRCLE S.E. SUITE 5 PALM BAY, FLORIDA 32909 ^�S ENGINEERING & TESTING 250 S.W. 13TH AVENUE POMPANO BEACH, FLORIDA 33069 FIELD DENSITY TESTS OF COMPACTED SOILS DATE: 8/15/08 ORDER NO: 08-2439 PERMIT NO. 08070253 CLIENT: PAUL DAVIS RESTORATIONS ADDRESS: 1950 SW BILTMORE STREET, PORT ST. LUCIE, FLORIDA 34984 PROJECT: PROPOSED RESIDENCE BUILDING PAD INDIAN RIVER ESTATES ADDRESS: 5900 SUNSET FORT PIERCE, FLORIDA MATERIAL DESCRIPTION: BROWN SAND LOCATION: 10' DIAG FROM NW CORNER LOCATION: 10' DIAG FROM SE CORNER LOCATION: 10' DIAG FROM SW CORNER LOCATION: LOCATION: LOCATION: FIELD DENSITY METHOD A.S.T.M. D-2922 DRY DENSITY P.C.F. IN THE FIELD 103.7 103.0 104.3 • MOISTURE 7.4 6.8 7.9 • COMPACTION IN THE FIELD 96.7 96.1 97.3 • COMPACTION REQUIREMENT 95% PROCTOR VALUE, P.C.F. 107.2 OPTIMUM MOISTURE, % 12.7 LABORATORY NO. P-999 DEPTH IN INCHES 12IV �" PROCTOR A.S.T.M D-1557 METHOD RECEa AUG 21 2008 Public Works REMARKS: SOIL NOT TESTED BELOW FOOTINGS St. Lucie County, ivy TESTED BY: SL Respectfully submitted, CHECKED BY: KM — — WISSAM S. NAAMANI, P. As a mutual protection to clients, the public and ourselves, all reports FEDERAL ENGINEERING & TESTING are submitted as the confidential property of clients, and authorization FLORIDA REG. #39584 for publication of statements, conclusions or extracts from or regarding CERTIFICATE OF AUTHORIZATION # 5471 our reports is reserved pending our written approval. A density test determines the degree of compaction of the tested layer of material only. A density does not replace a soil bearing capacity determination. Jun-14-2002 01:05pm From -SAVANNA CLUB +5618785656 T-468 P.001/001 F-761 St Lucie County Inspections 2300 Virginia Avenue Ft Fierce, FL 34982 (772) 462-2172 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT # St-c - 01301- 09s3 JOB ADDRESS e� ` 00 sucoSe F QV/0 ion _\ BUILDER PRUL DR-v=.s 1-?Es7-02AT,'0/V -� REM6 PEST CONTROL M PEST CONTROL LICENSE # We, the undersigned, hereby certify that we have pretreated the above -described construction for subterranean termites in accordance with the standard.. of the National Pest Control Association. Square feet of area treated: (p00" Percentage of solution: Date of treatment: B - o s - O'S ® Footing ❑ 1 sr Treatment ❑ Re -treat ❑ Slab ❑ 1st Treatment Q Re -treat Driveway Q 1st Treatment ® Retreat ❑ Pools ❑ 1st Treatment Chemicals used: �+?oS3u� \� Total gallons used: Coo Time of Treatment: q, . s FBC104.2.6 Certificate of Pmrective 7rearmentforprevention of termites. A weather resistant jobsite posrMg board shall be provided;* receive duplicate Treatment Certificates as each required prorecrive treatmenr is completed, providing a copy for the person the permit is issued to and another copyforthe buildingrermir,fles. TheTreatmentCervy1cateshall provide the product used, id--ntizy of the applicator, time and date of the treatment, site location, area treated, chemical used, percent concentration and number of gallons used, to establish a veritable record of protecrEve treatment_ If the soil chemical barrier method for termite prevention is used, final =arior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. ❑ Re -treat Other ;4jC)1' TU A"F 1st Treatment Re -treat . 0 Perimeter for Final Inspection NOTE. Signature of exter>ntinatolr Vhertie roust be a completed form for each required treatment or re4reatment and this form must be oft the job site to be picked up by the inspector at time of each inspection or the scheduled tr:spection will Revised 6R9/03 dmp fail and a re -inspection fee charged. Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stiucleco.gov/ce Issued: 08/15/2008 Job Location: 5900 SUNSET BLVD Permit Type: Building (Miscellaneous) Job Description: BUILDING PERMIT Conf #: 684 Permit #: SLC- 0807-0253 City: FORT PIERCE CONSTRUCTION OF LIVING AREA TO BACK OF HOME ( FOR SINGLE FAMILY RESIDENCE) THEY ARE ADDING 1 BEDROOM AND 1 BATH Page 1 S/D Indian River Estates Unit 8 Lot: 19 Block: 65 Parcel: 3402-609-0497-000/2 Contractor CAROTHERS, GARY D PAUL DAVIS RESTORATION & REMOI (772) 340-2080 1950 SW BILTMORE ST PORT ST LUCIE, FL 34984 Property Owner ROBERT E THIERY (772) 465-7164 5900 SUNSET BLVD FORT PIERCE, FL 34982-7525 Property Owner MARYON A THIERY (772) 465-7164 5900 SUNSET BLVD FORT PIERCE, FL 34982-7525 Setbacks Left: 12.81 Right: 14.38 Front:24.35 Rear: 47.39 Zoning: RS-4 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 571.00 Minimum Floor Elevation: Flood Map: 281G Flood Zone: AH Elev: 20 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN, FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section'11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. I - St. Lucie County Building . Zoning • 2300 Virginia Ave to Fort Pierce, FL 34982 BUILDING PERMIT SUB -CONTRACTOR SUMMARY `-. I�liL G✓bovs- f lc.,A-a-.4o, 11.^ will be using the following sub -contractors for'the (Company/Individual Name) project located at ��QC) cS L V► _S•G (Street address or Property Tax ID #) It is understood that if there is any change of status regarding the participation of any of the sub -contractors listed below, I will immediately advise the Building and Zoning Department of St. Lucie County. Trade- Name of Company/Contractor St. Lucie County/ State of Florida License Number' Electrical U e, t R- Plumbing, HVAC/ Mechanical Roofing S'&c_ �r6mlerpl 1' ,co. % Gas PERMT NUMBER: 0 6 0 —6,2 �i 7 ISSUE DATE: l ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT 08O) - 0�S3 SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: State of Florida Certification Number (If applicable): Eades Electric:. LLC the Electrical (type of construction trade) (companyfindividual name) 24244 ER0010293 sub -contractor for has agreed to be (name of the prime contractor) for the project located at _5—�G7J _<1, re f Z/ It is understood that, (street address or property tax ID #) if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor Form (SLCCDV.FORM NO.004-00). BUSINESS QUALIFIER (original signatures required): Samuel P. Eades signature Print name business name: Eades Electric L .0 address: 949 S.W. Jeremko Ave. city,state,zip: Port St. Lucie, FT, 34993 phone: (772) 370-2113 OFFI�C-_E�USEO;,NLM. Date PERMIT # 0 5 D 7— D,;' 50 ISSUE DATE SLCCDV FORM NO.: 002-00 J � � ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZON*G DEPARTMENT ]HUM)ING PERMIT SUB -CONTRACTOR AGREEPAMi T St_ Lucic Coway Contractor CertificationNumber_ State ofPlorida Certification Number (Ifa"iicable)_ C 5c r) "7a L&On9 PC'_e- V I U M10 l 1\r a w / have agreed to be the (Company Naase/Individua1Nanne) sub -contractor for �(� u (Jp _S ®S 7 y) S' (Type of Trade) i (primary Contractor) for the project located at l 6 o S4,q C�? l AJ _ (Project Street Address or PropertyTax ED 4) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the.Bufflding and Zoning Department of St Lucie G- pnty:by peisomlly filing a Cliange of Contractor notice. (Form: SLCCnv Tio. 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ORIGINAL SIGNATURES ARE REQUIRED J1611- I - - , f 'V% r»e-I I A IN] r ► IGNA - , f PRINT NAME j _ DATE Business Name: _ ' 1A C_ e � l )On 1�) 1A=LQ' ZL2 Cj Address: .- I d'a S 4 V L a C el City/Statc/Zip: .Phone: 6 5 emat): ter: FILE USE ONLY , = PERMIT # Q Z 0,7 ISSUE DATE 7•H 47afi7-n+70-7i i isson einseeii simn Inee4 d7.S:7.L 90 9L Inf f ST. LUCIE COUNTY PUBLIC WORKS BUILDING & ZONING DEPARTMENT BUILDING PERMIT SUB -CONTRACTOR AGREEMENT St. Lucie County Contractor Certification Number: Lf yQ (o State of Florida Certification Number (If applicable): P, r`, meS %Jeo__�`. )� 4 ,- 8- 10 have agreed to be the (Company Name/Indivi al Name) Ny i+C- sub -contractor for (Type of Trade) (Primary Contractor) for the project located at :Sq on S ur, s k R i,jc` P i P; -e rc -e (Project Street Address or Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project, I will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice. (Form: SLCCDV No. 004-00) BT,JfINESS QUALIFIER (Name of the Individual shown on the Contractor's License) ARE REQUIRED cz.mes _F Gr; mes %-15 -©$ PRINT NAME DATE Business Name: G r` k "es mo_�i r)G d �C Address: 3C G-,-/ '/�l l_l S t City/State/Zip: F-t- P, Cry Phone: H % l —g7 / / email: OFFICE USE ONLY: PERMIT # I ISSUE DATE I I ST. LUCIE COUNTY PUBLIC WORKS . BUILDING & ZONING DEPARTMENT BUR.DING PERMIT SUB-001MRACTOR AGREEMENT St. Lucie County Contractor Certification Number_ State of Florida Certif catio'n Number (wappucabk): `C C J (0 � z S-�ev-e. Fed A + P r- , )RO0 �7 t n C� have agreed to be the (Company Namellndividual Name) Q. Roo ►'1 c� sub -contractor for Pc,,i rA tills (Type of Trade) (Primary Contractor) for the project located at ` 0 (D L -, Sf- 1 (Project Street Address or Property Tax ID #) It is understood that, if there is any change of status regarding our participation with the above mentioned project,1 will immediately advise the Building and Zoning Department of St. Lucie County by personally filing a Change of Contractor notice_ (Form: SLCCDV No_ 004-00) BUSINESS QUALIFIER (Name of the Individual shown on the Contractor's License) 0R1d&LS1GNATVRES ARE RE UI"RED 5I ' TURF : PRINT NAME DATE Business Name: Address: cityistatclz;p: .PLone: P(Q �(Sg x fi co (at ' Ord- USE ONLY: ? tM S-S -S20 -3Ra-0 6D-7-•0 email: 7'YH i,rob7-n+,C-711 iQP[Y% nimpttai l SIAP_(7 VIPJ (i4.0'71 or) CI in �JL�E COG ST. LUCIE COUNTY BUILDING & ZONING r VIRGINLA AVENUE RTT FORPIERCE, FL 349825652 • F�OR10P • 561462-1553 FILLED LANDS AFFIDAVIT I, the undersigned, am the owner of the following described property: (Tax ID/Legal description/Address) for which I have applied to St. Lucie County for a Final Develo ment Permit. In accepting this Final Development Permit, BP Number 08 -� D� S I acknowledge that as owner of the above described property, and in accordance with Section 7..04.01(D), St. Lucie County Land Development Code, I shall be responsible for assuring adequate drainage so that the immediate community WILL NOT be adversely affected. I further acknowledge that in granting this permit for the development of this property, St. Lucie County -is neither obliged nor liable to provide for, or maintain in any form, adequate drainage off my property which will not adversely affect the immediate community. 1-7el--c DatePro Property Owner Name Pro a yOwner Signature STATE OF FLORIDA. COUNTY OF 0 C1 C' e 'ACKNOWLEDGED BEFORE ME THIS / Sf DAY OF L , 20 6 BY_. / '�fLf/Iris✓ 71n1 WHO IS PERSONALLY KNOWN TO ME OR WHO HAS PRODUCED W AS IDENTIFICATION.. SIGNATURE OF NOTARY ME OF NOTARY AR9, 4y6 Notary u Ilc State ot Ionda 'Kad Thomas Moore (SEAL) NOTARY PUBLIC TITLE '�;' My Commission DWMASS N NUMBER Ot M1 �9 EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT — SAINT LUCIE,COUNTY FILE # 3227528 OR BOOK 25' PAGE 252, Recorded 07/02/201" "sit 01:45 PM AFTER RECORDING -RETURN TO• ( -I 1 PERMIT i� E IT NUMBER• � li,i.;y�:r.r:•n'a•rs'�s:i�a•srs•Os:h::;r:nr•i NOTICE OF COMMENCEMENT The undersigned hereby given notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida statutes the following information is provided in the Notice of commencement. DESCRIPTION OF PROPERTY (Legal description and street address) TAX FOLIO NUMBER: 34C'a loc,-o4 % J -&nc ••• ,I SUBDIVISION BLOCK_ TRACT LOT it % BLDG UNIT C�$ —T 2. GENERAL DESCRIPTION OF IMPROVEMENT: 3. OWNER INFORMATION: a. b. Address h, d. Name and address of fee simple titleholder (if other than owner) r 4. \\CONTRACTOR'S NAME, ADDRESS AND PHONE NUMBER 5 c 1150 S V( ni i'0 Moc, rc y,l oSL F c. interest in property, 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: W 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: r.; 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (])(a) 7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 8. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is specified) , 20 of OwiYer or Owner's Authorized Offcer/Director/Partner/Mauager fAZ. Print Name and Provide Signatory's TitlelOfficc State of Florida Countyof 1iG i S L The foregoing instrument was acknowledged before me this I day of 'jV 7- 20 By as (Name of person) (Type of authority...e.g. Owner, officer, trustee, attorney in fact) For (Name of party on behalf of whom instrument was executed) lly Known_ or produced the following type of ID: % _ �,wr Notary Public rida ` 161-2. / Karl Thomas 14111150. d My Commission DD474179 (Printed Name of Notary Public) (S' ublic) ry,? 1,0 Expires 09121/2009 Under penalties of perjury, I declare that I have read the for(gq>:fzg—f zEnd that thg;facts in'`tit are true to the best of my knowledge�and� belief (section 92.525, Florida Statutes). �' L � r (! tt1 T Y THIS o'-IRTIFyTHATTHISISA �� Signature(s) o Ownei (s) or Owner(s)' Authorizgd bfiicerf�prF:eckor/Par# er/ age rwho signe " o e:t' I tort /�ILl1 I�CJh�l r .�t f rdL srj , Rev. 011/3072007(Re s �n,�,, Si,:✓ c;-�/ 7 p ��oulasv._ Da4e:' -� T `71�118 r- M -9 0 0 1 ri I -w ��� t - �.; I, . 11-11 Q V' in ti 0% co 0 N C4 N n CL o. DRAIN FIELD* J LOT 38\ WELL (OCCUPIED) \ INDIAN RIVER ESTATES UNIT NINE PLAT BOOK 10, PAGE 74 ST LUCIE COUNTY, FLORIDA LOT 39 (VACANT) FND 5/8" IR : 0� \ "NO ID" I S O'00'00"E 5' CL FEN COR/ •� I� 0.3' N/0.1Ei \ LOT 18 PROPOSED c DRAINFIELD (OCCUPIED) ,' a I 625 SF o WELL '1 / In STgP 19' J W 21.92' F- 0 •.•�'� / N 1 1Q n ST — _ 6' WD 112.85'149.00 : 0.4' FEN CDR N/59.6' E 1 5' CL / iN I.LI , O N 0 Z , 12.81' BRAN FND 1/2" IP FIELD±I FND 1/2" IF1 d N `L "NO ID" I "NO ID N 00'0 SUNSET BOULEVARD 80.00' P&M FEN COR, 0.7' S/12' W LOT 19 68�02 SCALE 1"=SO ` i SPECIAL 'PURPOSE PLOT P ~UiLTH DEPT SITE Piiif i3ppp�D. F R to ` SWREEDES At, owsm LOT 40 �� � FORI (VACANT) � 1 a�iERs of • �,cm-- ,.�: 1�1 FND 1/2" IP LIMITS OF PLAT BLOCK 65 I LOT 20 { a (OCCUPIED) , o F *71 04 N to N FEN COR \ 1.6' S/59.5' E � \� i O / \ o o R Z 5 /ELL i N00'00'�O"W 80.0 '(P ) w;P `FND 1/2" IP 155.00'(P) I "NO ID" 155.07'(M) t wM � o ' 0 1 ci / !r 1 \ EP / _ \ 80.00' P _ _ EP 130:00'(P) % \N00'00'00"E \ 210.00'(P) / 20' ASPHALT in 27.00' mtc PFF��P6SED o ADDITION °? ' 14.: 52.77' $' i EXISTING A STORY WOOD/CB$ RESIDENCE FFY=19.66 b 17.75' c 20.57' i n COVERED r O j R PROPOSED PORCH 30.00' 14.35- 1 114.42' 9.9, N CONC yEii DRIVE ��("�� I � W O I� m 25.00' "NO .� VELCON GROUP, INC. �o V G ENGINEERS do SURVEYORS 702 S.W. PORT ST. LUCIE BLVD. PORT ST. LUCIE, FLORIDA 34953 80 R/1�V\ / � SEE REVERS SIDE FOR (772) 879-0477 BMNGVD \ / SYMBOL LEGEND AND (772) 871-6659 (FAX) � ELEV-18.00 /- -_SET PK NAIL / ABBREVIATION SCHEDULE LICENSE BUSINESS 14942 LEGAL DESCRIPTION: LOT 19, BLOCK 65, INDIAN RIVER ESTATES UNIT EIGHT, AS RECORDED IN PLAT BOOK 10, PAGE 73, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. ADDRESS: 5900 SUNSET BOULEVARD FORT PIERCE, FLORIDA NOTES: SUBJECT TO ANY APPLICABLE EASEMENTS, RIGHTS -OF -WAY, OR OTHER RESTRICTIONS OF RECORD. A SEARCH OF THE PUBLIC RECORDS HAS NOT BEEN MADE BY THIS OFFICE. BEARINGS SHOWN ARE RELATED TO THE CENTERLINE OF SUNSET BOULEVARD, AS SHOWN ON THE PLAT OF RECORD. LEGAL DESCRIPTION PROVIDED BY CLIENT. ELEVATIONS ARE IN FEET AND RELATED TO THE BENCHMARK SHOWN HEREON. PROPERTY LIES IN F.I.R.M. ZONE "AH" (BASE FLOOD ELEVATION 17.0'), AS SHOWN ON PANEL 120285-0281G, DATED 11/4/92. FLOOD ZONES ARE APPROXIMATE AS SCALED FROM FLOOD INSURANCE RATE MAPS. IN ACCORDANCE WITH CHAPTER 611317-6.003, ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY, IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY. THERE ARE NO ABOVE GROUND ENCROACHMENTS UNLESS OTHERWISE SHOWN. UTILITIES SHOWN HEREON ARE VISIBLE ABOVE GROUND FEATURES. ADDITIONAL SUBSURFACE UTILITIES AND OR FEATURES MAY EXIST. THERE MAY BE ADDITIONAL RESTRICTIONS THAT ARE NOT SHOWN ON THIS SURVEY, THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. THIS PLAN INFORMATION TO BE VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. AFTER 90 DAYS FROM THE LAST FIELD DATE, THIS SURVEY WILL NEED TO BE UPDATED FOR A CURRENT SEAL AND SIGNATURE. CERTIFIED TO: PAUL DAVIS RESTORATION & MODELING TEAM ROBERT F. KEMERSON „ IR PROFESSIONAL SURVEYOR AND MAPPER STATE OF FLORIDA # 6285 PAUL DAVIS RESTORATION & MODELING TEAM REVISIONS NO. DESCRIPTION DATE BY 1 BOUNDARY 06/30/08 SE 2 PLOT PLAN . 07/02/08 RC 3 ADD WALK & PORCH 07/21/08 RC 4 REVISE PLOT PLAN D7/25/08 BK )ATE IN FIELD: 06/25/08 CHECKED BY: BK FIELD BOOK: PAGE: 08-05 23-24 JOB NO.: 08-052 ABBREVIATIONS A/C AIR COND17701VING AC ACRE ?:. AL .ALUMINUM ANC_ � r•ANCHOR It!.', AP ANCHOR POLE _ •-APRX,'.. • :-APPROXIM4TE g -ASP ASPHALT .: BE `;:; --'BUFFER':,EASEMENT •>'- `"e BFP BA CK A OW PREVEN TOR SYMBOL LEGEND POWER POLE T R TELEPHONE RISER ® WATER METER 0 CONCRETE POWER POLE ++ X EXISTING ELEVATION CONCRETE MONUMENT O SET ROD & CAP LB# 4942, UNLESS OTHERWISE NOTED O FOUND MARKER AS NOTED DELTA ANGLE F-- GUY ANCHOR PROPOSED ELEVATION OS SANITARY MANHOLE, QD DRAINAGE MANHOLE (4:1 SLOPES ARE MAXIMUM) `,'BLDG' "BUILDING BLK BLOCK BENCHMARK— BOC BACK' OF BP BRICK - PAVERS ° BOW BACK OF WALK BRG BEARING BW BARBED WIRE C&G CURB AND CUTTER C&T CULPEPPER & TERPENING C/O CUT OUT C CALCULATED CA TV CABLE TELEVISION BOX CB CATCH BASIN CBS CONCRETE BLOCK STRUCTURE CHD CHORD CI CURB INLET CL CENTERLINE CLF CHAIN LINK FENCE CM CONCRETE MONUMENT CUP CORRUGATED METAL PIPE CO CLEAN OUT COR CORNER CONC CONCRETE. CONST CONSTRUCT70N COV COVERED CE COVERED ENTRY" COVP COVERED PORCH CPP CONCRETE POWER POLE CPPIPE CORRUGATED PLASTIC PIPE CS CONCRETE SLAB A DELTA ANGLE D/F DRAIN FIELD D DEED INFORMATION DC 'D" CURB DE DRAINAGE EASEMENT DI DROP INLET D14 DIAMETER DIP DUCTILE IRON PIPE DMH DRAINAGE MANHOLE DUE DRAINAGE & UTILITY EASEMENT EC EDGE OF CONCRETE ECP ELEC77?1CAL CONTROL PANEL EL ELEVATION ELEC ELECTRIC ELEV ELEVAT70N EM ELECTRIC METER ENC ENCROACHMENT EOW EDGE OF WATER EP EDGE OF PAVEMENT ESB ELECTRIC SERVICE BOX ESMT EASEMENT EXIST EXIS77NG EXT EXTENDED F FENCE FC 'f " CURB l - S S ADC FIRE DEPARTMENT CONNECTION PCP PERMANENT CONTROL POINT -FECRR FLORIDA EAST COAST RAILROAD PF PLASTIC FENCE FFE FINISHED FLOOR ELEVATION PC PAGE FH FIRE HYDRANT PI POINT OF INTERSECTION FNO FOUND PK&D PARKER KALON NAIL AND DISK FOC FACE OF CURB PK/7-T PARKER KALON NAIL AND TIN TAB FOW FACE OF WALK PLS PROFESSIONAL LAND SURVEYOR FPL FLORIDA POWER & LIGHT POB POINT OF BEGINNING GA GREEN AREA POC POINT OF COMMENCEMENT GMH GAS MANHOLE PP POWER POLE GND GROUND PRC POINT OF REVERSE CURVATURE GRD GRINDER PRO PRORATED DISTANCE HC HEADER CURB PROP PROPOSED HOPE HIGH DENSITY POLYETHYLENE PRM PERMANENT REFERENCE MONUMENT HGW HOG WIRE PSM PROFESSIONAL SURVEYOR & MAPPER HW HEADWALL PSWL PLASTIC SCALE HYD HYDRANT PT POINT OF TANGENCY /CV IRRIGATION CONTROL VALVE PUE PRIVATE UTILITY EASEMENT ID IDENTIFICATION PVC POLYVINYL CHLORIDE ILL ILLEGIBLE RIC ROD AND CAP INT INTERSECTION R/W RIGHT—OF—WAY INV INVERT R RADIUS lP IRON PIPE RCP REINFORCED CONCRETE PIPE IP&P IRON PIPE & PLUG RGE RANGE 1R IRON ROD RLS REGISTERED LAND SURVEYOR lW IRRIGATION WELL RP RADIUS POINT L LENGTH RR RAILROAD LB LICENSED BUSINESS RRS RAILROAD SPIKE LFTS LIFT STATION S/W SIDEWALK ' LME LAKE MAINTENANCE EASEMENT SAN SANITARY SEWER MANHOLE LOC LOCATION SBT SOUTHERN BELL TELEPHONE LP LIGHT POLE SEC SEC77ON LS LICENSED SURVEYOR SF SQUARE FEET M MEASURED SHP SHIP SPIKE OR BOLT MAX MAXIMUM SLP STREET LIGHT SUPPORT POLE MB MAIL BOX SMH SANITARY MANHOLE MEAS MEASURED SPC STATE PLANE COORDINATES MES MITERED END SECTION STY STORY MH MAN HOLE Sr SEP71C TANK MHWL MEAN HIGH WATER LEVEL SV SANITARY VALVE MIN MINIMUM SWL SWALE MN MAGNETIC NAIL TA TOP OF ASPHALT MIT MITERED END TM TAX MAP MW MONITORING WELL 7iUH TELEPHONE MANHOLE . N&D NAIL AND DISK TOO TOP OF BANK N NAIL TOE TOE OF SLOPE NA NON —APPLICABLE TP TRAVERSE POINT NA VD NORTH AMERICAN VERTICAL DATUM TR TELEPHONE RISER NGVD NATIONAL GEODETIC VERTICAL DATUM TRANS TRANSFORMER NO NUMBER TSB TRAFFIC SIGNAL BOX NIS NOT TO SCALE TT TIN TAB O/A OVERALL TWP TOWNSHIP 0/S . OFFSET 7YP TYPICAL OE OVERHEAD EASEMENT U/C UNDER CONSTRUCRON OHE OVERHEAD ELECTRIC UE UTILITY EASEMENT OHU OVERHEAD UTILITY UP U77UTY POLE OR OFFICIAL RECORD UR UTILITY RISER ORB OFFICIAL RECORD BOOK UW UNDER WATER P/C PROPERTY CORNER VC VALLEY CURB P/L PROPERTY LINE VLT VAULT P PLAT WD WOOD PAVE PAVEMENT WL WATER LINE PB PLAT BOOK WM WATER METER PC POINT OF CURVATURE WP WELL POINT PCC POINT OF COMPOUND CURVATURE WPP WOOD POWER POLE PCO PRESSURE CLEAN DUT (SANITARY) WV WATER VALVE APPENDIX 13-D FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 600C-04R Residential Limited Applications Prescriptive Method C CENTRAL 4 5 6 Small Additions, Renovations 8c Building Systems Compliance with Method C of Sub -Chapter 6 of the Florida Energy Efficiency Code may be demonstrated by the use of Form 600C-04 for additions of 600 square feet or less, site -installed components of manufactured homes, and renovations to single- and multiple -family residences. Allemative methods are provided for additions by use of Form 600E-04 or 600A-04. PROJECT NAME: . BUILDER: AND ADDRESS:-1�zl - PERMITTING OFFICE: CLIMATE ZONE: 40 5 El 6 04 OWNER: PERMIT NO.: JURISDICTION NO.: SMALL ADDITIONS TO EXISTING RESIDENCES (600 square feet or less of conditioned area). Prescriptive requirements in Tables 6C-1, 6C-2, and 6C-3 apply only to the components of the addition, not to the existing building. Space heating, cooling, and water heating equipment efficiency levels must be met only when equipment is installed specifically to serve the addition or i3 being installed in conjunction with the addition construction. Components separating unconditioned spaces from conditioned spaces must meet the prescribed minimum insulation levels RENOVATIONS (Residential buildings undergoing ren- ovations costing more than 30% of the assessed value of the building)_ Prescriptive requirements in Tables 6C-1 and 6G2 apply only L)!he components and equipment being renovated or replaced_ MANUFACTURED HOMES AND BUILDING& Only site -installed components and features are covered by this form. BUILDING SYSTEMS. Comply when complete new system is installed. 1_ Renovation, Addition, New System or Manufactured Home 2. Single-family detached or Multiple -family attached 3. If Multiple -family -No- of units covered by this submission 4. Conditioned floor area (sq. fL) S. Predominant eave overhang (ft.) 6. Glass type and area: a. Clear glass b. Tint, film or solar screen 7. Percentage of glass to floor area 8. Floor type and insulation: a. Slab -on -grade (R-value) a b. Wood, raised (R-value) c. Wood, common (R value) +- d. Concrete, raised (R-value) r• e. Concrete, common (R-value) a 9_ Wall type and insulation: a. Exterior: 1. Masonry (insulation R-value) 2_ Wood frame (Insulation R-value) b. Adjacent: 1_ Masonry (Insulation R-value) 2. Wood frame (Insulation R-value) c. Marriage Walls of Multiple Units' (Yes/No) 10. Ceiling type and insulation: a. Under attic (Insulation R-value) b. Single assembly (Insulation R-value) 11. Cooling system* (Types central, room unit, package terminal A-C., gas, existing, none) 12. Heating system' (Types: heat pump, elec. strip. natural gas. LP -gas a h.p., room or PTAC, existing, none)' " 13_ Air distribution system* a_ Bacldlow,damper or single package systems' (Yes/No) b. Ducts on marriage walls adequately sealed- (Ye'sfNo) 14. Hotwatersystem: (Types elec., natural gas, other, existing, none) Pertains iD manufactureo nome9 w,th site -installed compone(ts. lease Print 1. 2. 3. 4_ 5. S�s Double Pane 6a. sq. ft. sq_ ft_ 6b. sq. It. sq. ft. Be R - ` 09 tin. it. 8b. R - sq. ft. 8c. R = sq. ft. 8d- R = sq_ tL Be. R = sq. ft. ga -1 R =—vD_ 483 sq. ft_ 9a-2 R = sq. it. 9b-1 R = sq. ft 9b-2 R = sq. ft. Be. 10a. R JeL sq. ft. 10b. R = sq. It. 11. Type: Osafiwd— sEERA=-sR; _ 13.0 12. Type: ( HSPF/COP/AFUE• •.1 13a. 13b. 14_ Type: EF: 'i CK I herchy cerliPr Ihat lha pU,c and specifiatians c cored try,haafaution ere in compliance,:91h Rails, of plans and sp ciffaliors Grated by this calculation indialas mmplance+:ith the flmidi Ihr Florida In o PREPARED BY. Energ, Code. Before, coma:lion is completed, this bidtding rill be inspected for compliance in ante c91h Section 553.908. F.S. r E:.-(a"_ i -� ...% B It1G OFFICIAL" . hereb, rerBry that building is in compliance :; Ih the Florida Enugy Cade DATE:, . _ FLORIDA BUILDING CODE -BUILDING j Y Y ' ;i ;apt d -ti•:' , .F� i 13-D.35R ar APPENDIX 13-D TABLE 6C-1: PBESCRIPrIBE RED1tinEMclrrs r-nR smm t xnmmnue r,n° __.. __ . Climate Zones 4, 5, 6 TO EXISIH6 BUILDINGS AIMS[rC411STA1 I m Prim Climate n. COMPONENT MINIMUM INSULATION INSULATION INSTALLED Concrete Block R-5 Frame. 2'x4' R-11 1 Frame. 2' x 4' R.79 3 Common. Frame R-11 Common. Masonry RS Under Attic R-30 cu Single Assembly. Enclosed z Frame Fi-19 w Metal Pans R-13 o Single Assembly. Open R-10 Common. Frame R-11 in cc Slab-on-grado No M"mimum Q Raised Wood R-11 0 Raised Concrete R-5 Common. Frame R-11 U In unconditioned space R-6 o in condllloned space No minimum EQUIPMENT MINIMUMI=- EFFICIENCY z CenralxC -Split SEER =13.o- O - Single Pkg. SEER =13.0- Room unit or PTAC EER =8.5- Electric Resistance ANY z Heatpump-split HSPF=7.7' ingle hry' Room unit oSPTHP - COP = 2.7- HSPFNCOP = v Gas natural or_pmpano AFUE =.78 AFUE _ a U) Fusion AFUE=.78 AFUE= 1-w Electric Resistance EF=.92 EF= •�a _ ¢ Gas: natural or LP -gas EF =.59 EF = 3 Fuel On EF=.54 EF= r y TABLE 6C-2: PRESCRIFI VEREAUIREMENTS FOR GLASS AREAS IN ADITMOBS ORLY .See Table 13-607.1ASC.a2and 73 6a61 ADC 32 Maximum percentage glass to floor area allowed is selected by TWO, overhang length. and solar heat gain coefficient. Maximum P; _ Inslaned °o = _ GLASS TYPE OVERHANG, AND SOLAR HEAT GAIN COEFFICIENT REOUIRED FOR GLASS PERCENTAGE ALLOWED UP TO 20°b UP TO 30% UP TO 40°a UP_TQ 50% Single Double Single Double 9 Sin to Double Single-' • "� Double OH-SHGC OH-SHGC OH-SHGC OH-SHGC OHSSHGC OH-SHGC OH-SHGC OH-SHGC V-.87 O'-.78 2'-.87 1•-.78 3'-.87 2'-.78 4'-.87 778 9-.75 1'-.75 0'-.61 2'-75 1'-.61 0'-57 u -.75 2'-.61 1--w 0'-.44 2'-.57 1' - .44 0'-.39-.35 Gel certified SHGC from the manufacturer or use defaults: Single dear SHGC =.75. double clear SHGC=.66. and single lint SHGC =.64 TABLE 6C-3 MINIMUM REQUIREMENTS FOR ALL PACKAGES COMPONENTS SECTION REQUIREMENTS Exterior Joints &Cracks 6C6.1 To be caulked. gasketrrrl weathersCHECKtripped or olhenvise sealed. 1' ^ Exterior Windows & Doors 606.1 Max.0.3 cfrWsq.IL tvindoivarea: S drWsq.ft. doorarea. Sole & Top Plates 606.1 Sole plate; and penetrations through top plates of extetiorvralls must be seated. Recessed Lighting 605.1 Type IC rated with no penetrations (hvo allomativas atlovred). ` Multistory Houses 606.1 Air barrieron P01imeterof floor cavity between floors. Exhaust Fans GC6.1 dExhauost ans vented to uneondtioned space shall have dampersk.. except for conil " iori devices vrith integral exhaust Combustion Healing 606.1 Combustion space and s:alerhealing systems must be provided with outside combustion air. except for direct vent appliances. Water Heaters 612.1 Complywith efficiency requirements inTable 61P-1.ABC.3ZSwitch ardearfy_AeKe 8(cuilbreakereledricorculoll (gas) must be provided External or built-in heal Trap required for vertical pipe risers. - Srvimming Pools & Spas 612.1 Spas & healed pools must have covers (except solar healed). Noncommercial pool healers must have minimum thermal efficiency of 7wmust hthermale.a pump timer. Gas spa & Hot Water Pip= 0121 Insulation 1s required for hot water circulating systems (including heat recavt:ry dnifs): Shower Heads 612.1 l^/aler Row must be restricted to no more than 25 gallons per minute at Bo psig. HVAC Duct Construction, 610.1 All ducts. fillings. mechanical equipmanlandplenum chambers shelf be mechanics led and Ity attached. sealed. insulat Insulation & Installation installed in accafdance viilh the criteria of Section 610.1. Ducts in allies most be insulated to a minimum of u l HVAC Controls lion, f Separate readdyaccessible manuaf or automatic thermostat for each system. GENERAL DIRECTIONS I. OnTabla GC-7 indicate the R-valueof the insulation being added to each component and theel ioenry levels of the equipment being installed. Ali R-vatuesand efficiencies installed must meelar exceed the minimum values r61ed. Cempenents and equipment nedtlerbeing added norreoavaled may be fall blank 2. ADDRIONSONLY.Determinethepercenlageoinewglas.focon6litinedgooraininthezdddionas(alkimTalaltheateasafa6g6sswindoers,sedingglassdamsandaimdoorpanels.Doublethe area of all nanvadkO roof Class and add it to the previous total. When Ot iss in existing eldedorllagS is bem0 removed oreltdosed by the addition, en amount equal lathe total area of this aim may be subtractedfromthetotalglassarea-DivideIhead)ustedglassareatotalbytheclmditioraditoarareaoftheadd mlr.Modpyby100togetthepead.Findthelargestgasperrentageunderwhichyour calculated percthe entage falls anTahle6C2P.resajpfivtsa yhxn.XThe Walat=(smgleordoublepane)andthem2_rtrang(Off)P*Wr2liftasdarheaigainlneRitiarlt(SHGC).Foragimaj]tasstype and oydrang.eoverhngandsolar heatpaiflmalfrp€fitaw.7edis gchralglmswindoasanddoarsP mthe exteriaxc oflJfahoasendbeing reurstagedinthe adddiondonot liavela mmlilywklhlheovarltangandsalarheatgaincaeJficiarlLfeQuir�rtrtYY�fps Tabk�r2ABnewgtassinlJaaddm indicated.TheOverhang(OH)dstancbismeasUte ndiwh}tyftdmthafacea2'A I' classic -W111111the feWbementloroneofthe aptionsinThe Class penowlageCategory you 3. RENOVATIONS ONLY.Replacemenlgtas�neifd31o50�eetthe g poieand Byundertheoulermostedgectheavarhang. and whose lmrestedge does not extend further than 8feet franilieewerrhang.g.Glassareds�ut p�t�dp� used �e St= areas which are under at least a2fooloverhang tinted, gle-palte.tinted. double -pane dear or double -pane 4- BUILDINGSYSTEdS.Complywhenravrsystem'sinstalledforsysleminstalled. 5. Complete the ifdOmMion requested on the top frog of Pagel. 6 Read TdfnimumRequirements for SmaDAdditionsand RenovifitoWTab1e6C-3.and rbedkallapp6rati%a m 7 Read. sign and dale the'Owner/Agem'oedifkcagonslatemenlon page1. 13-D.36R FLORIDA BUILDING CODE - BUILDING Project Summary Entire House Project Information For: THIERY ADDITION 5900 SUNSET BLVD., FT. PIERCE,FL Notes: Design Information Job: Date: By: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Reative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 23082 Btuh Ducts 5324 Btuh Central vent (37 cfm) 1147 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 29553 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Area (ftz) Heatin 1861 Coolingg 11 A Volume (ft') 14904 14904 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 94 50 Heating Equipment Summary Make Trade Model Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 0 Btuh 29553 Btuh 24 OF 1140 cfm 0.040 cfm/Btuh 0.00 in H2O Sensible Cooling Equipment Load Sizing Structure 18350 Btuh Ducts 7751 Btuh Central vent (37 cfm) 614 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 25380 Btuh Latent Cooling Equipment Load Sizing Structure 2475 Btuh Ducts 2095 Btuh Central vent (37 cfm) 1556 Btuh Equipment latent load 6127 Btuh Equipment total load 31507 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Trane Trade XR13 Cond 2TTR3036A1 Coil 2TEC3F36A1 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13 SEER 23940 Btuh 10260 Btuh 34200 Btuh 1140 cfm 0.044 cfm/Btuh 0.00 in H2O 0.81 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. w1r101-1tsoft Right -Suite Residential 6.0.103 RSR31845 2008-Nov-12 09:13:59 ACCA C:1Program Files\Wrightsoft HVAC1AutoSave1THIERY RES.-PAUL DAVIS REST: REVISION.rrp Calc = MJ8 Page 1 [u.�xiL�at�cs�lc� Right-J Worksheet Job: Entire House Date: -' By: 1 Room name Entire House NEW BATH 2 Exposed wall 158.0 ft 12.0 ft 3 4 Ceiling height Room dimensions 8.0 ft p 8.0 ft heat/cool 6.0 x 12.0 ft 5 Room area 1863.0 ft2 72.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (W) Load number (13tuh1W *F) (Bt or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1N 1-.-C 13A=5ocs 0.125 n 3.50 - 2.22 216 186 651 414 0 0 0 0 1A-blom 1270 n 3556 17.90 . 30 0; 1067 537 0 .. • 0 0 0 13A-4ocs 0.143 n 4.00 2.55 144 102 408 260 0 0 0 0 IA-clom 1.270 n 35.56 24.81 24 0 853 595 0 0 0 0 11 IA-clom 13A-5ocs 1.270 0.125 n a 35.56 3.50 24.81 2.22 18 144 0 103 640 361 447 230. 0 0 0 0 0 0 0 0 10A-m 1.670 a 46.76 , .. 22.43 41' 0 1908 915 0 ' 0 -' 0 0 W 13A-4ocs 0.143 a 4.00 2.55 24 24 96 61 0 0 0 0 13A-4ocs 0.143 s 4.00 2.55 312 249 997 634' 0 0 0 0 IA-clom , IA-clom 1.270 1.270 s s 35.66 35.56 37.88 37.88 18 24' 18 24 640 .853. 626 835 0' 0 0 01 0 0 0 0 11DO 0390 s 10.92 11.31 21 21 229 238 0 0 0 0 W I-C 13A-5ocs 0.125 w 3.50 2.22 144 136 476 303 96 92 322 205 IA-clom 1.270 w 35.56 91.12 8 0 284 729 4 0 142 364 W. r-G 13A-flocs 1A-clom 0.143 1.270 . w :w, 4.00 35.66 2.55 91:12 280 8, 272 0' 1089 284 692 729 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 - 2.55 1.28 304 304 775 390 0 0 0 0 C 16B-19ad 0.049 - 1.37: 2.57 1863 1863 2556 4793 72. 72 99 185 F 22A-tph 1.358 7 38.02 0.00 1863 158 6008 0 72 12 456 0 6 c) AED excursion 1245 177 Envelope loss/gain 20177 14671 1019 931 12 a) Infiltration 2905 819 221 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances @ 1200 2 2400 0 0 Subtotal (lines 6 to 13) 23082 18350 11240 994 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 4 7 14 Subtotal 23082 18350 1243 1000 15 Duct loads 23% 42% 5324 7751 23% 42% 287 422 Total room load Air required (cfm) 28406 1140 26101 1140 1530 61 1422 62 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ' wrr,ghtsoft Right -Suite Residential 6.0.103 RSR31845 2008-Nov-12 09:13:59 '�� C:\Program Files\Wrightsoft HVACWutoSavelTHIERY RES.-PAUL DAVIS REST.-REVISION.rrp Calc = MJ8 Page 1 Right-J Worksheet Entire House Job: Date: By: 1 Room name NEW BEDROOM NEW WIC 2 Exposed wall 39.0 ft 0.0 ft 3 Ceiling height 8.0 ft heat/cool 8.0 ft heaticool 4 Room dimensions 1.0 x 414.0 It 7.0 x 4.0 ft 5 Room area 414.0 ft2 28.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ftq Load number (Btuh/ft;°F) (BtutUft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VJ✓ �--G 13A-5ocs 6.125 n 3.50 2222 168 138 483 3W 0 0 0 0 IA-clom 1.270 n 36.56 17.90 30 0 1067 537 0 ` 0 0 0 T--��� 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 n 35.56 24.81 0 0 0 0 0 0 0 0 `G 11 IA-clom 13A-5ocs 1.270 0.125 n a 35.56 3:50 24.81 2.22 0 '144 0 103 0 361- 0 230 0 0 0 0 0 0 0 0 yJ G 10A-m 1.670 a 46.76 22.43 - 41 0 1908 '915 0 0 0 0 W 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.55 0 0! 0 0 '' 0 0 0 0 IA-clom 1A-clom 1.270 1.270 s s 35.56 3556 37.88 37.88 0 0 0 0 -0 0 0 0 0 0 0 0 0 0 0 -0 11 DO 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 2.22 0 0 0 0 0 0 0 0 1A-clom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 W t--G 13A-4ocs 1A-c1`om 0.143 1.270 w, w 4.00 35.56 2.55 91.12 0 - 0 0 0' 0 0 0 0 0 0' 0 0 0 0 0 0 P 12C-Osw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 C 16B-19ad 0.049 1.37 2.57 414 414. 568 1065 28 28 38 72 F 22A-tph 1.358 38.02 0.00 414 39 1483 0 28 0 0 0 6 c) AED excursion 69 -1 Envelope loss/gain 5870 3123 38 71 12 a) Infiltration 717 202 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 6587 3325 38 71 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 9 0 0 14 Subtotal 6591 3333 38 71 15 Duct loads 23% 42% 1520 1408 23% 42% 9 30 Total room load 8112 4741 47 101 Air required (cfm) 326 207 2 4 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�g1-�tso Ft Right -Suite Residential 6.0.103 RSR31845 2008 Nov-12 09:13:59 C:1Program FileslWrightsoft HVAC\AutoSave%THIERY RES.-PAUL DAVIS REST: REVISION.rrp Calc = MJ8 Page 2 Right-J Worksheet Entire House Job: Date: By: 1 Room name CLST. TOILET 2 Exposed wall 0.0 ft 12.0 ft 3 Ceiling height 8.0 ft heat1cool 8.0 ft heatkpol 4 5 Room dimensions Room area 3.0 x 4.0 ft 12.0 ft2 6.0 x 6.0 ft 36.0 ft' Ty Construction U-value Or HTM Area (W) Load Area (ft) Load number (Btuh/ft2-°F) (BtutUW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.56 2.22 6 6 0 - 0 48 48 168 ' 107 1A-cloni 1.270 n 35.56. 1.7.90 0 0 0- 0 0 0 0 0 T--��� 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 n 35.56 24.81 0 0 0 0 0 0 0 0 `G 11 1A-clom 13A-5ocs 1.270 0.125 n a 35.56 3.50 24.81 122 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10A-m 1.670 a 46.76 . 22.43 0 0, 0 0 , 0 0 0 0 W 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 'nnYl 13A-4ocs 0.143 -s 4.00 2.55 0 -0. - 0 0 0 0 0 0 1A-clom AA-clom 1.270 1.270 s s 35.56 35.56 3788 37.88 0 0 0 0.: 0 0 0 0 0 0 0 0 0 0 0 11 D0 0.390 s 10.92 11.31 0 0 0 0 0 0 0 D 13A-5ocs 0.125 w 3.50 2.22 0 0 0 0 48 44 154 98 1A-clom 1.270 w 35.56 91.12 0 0 0 0 4 0 142 364 yJ �-G 13A-4ocs IA-clom 0.143 1.270 w . w 4.00 35.56 2.55 91.12 0 0 0 0 0 01 0 0 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 C 16B-19ad 0.049 - 1.37 2.57 12 12 16 31 36 36 49 93 F 22A-tph 1.358 - 38.02 0.00 12 0 0 0 36 12 456 0 6 c) AED excursion -0 178 Envelope loss/gain 16 30 970 840 12 a) Infiltration 0 0 221 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 16 30 1191 902 Less external load 0 0 0 0 Less transfer Redistribution 0 -16 0 -30 0 0 0 0 14 Subtotal 0 0 1191 902 15 Duct loads 23% 42% 0 0 23% 42% 275 381 Total room load 0 0 1465 1284 Air required (cfm) 0 0 59 56 Printout certified by ACCA to meet all reouirements of Manual J 8th Ed. ' wr�g f-vtsoft Right -Suite Residential 6.0.103 RSR31845 2008-Nov-12 09:13:59 C:1Program Files\Wrightsoft HVACVAutoSave\THIERY RES -PAUL DAVIS REST: REVISION.rrp Calc = MJ8 Page 3 Right-J Worksheet Enure House Job: Date: By: 1 Room name EXISTING HOUSE 2 Exposed wall 95.0 ft 3 Ceiling height 8.0 ft heat/cool 4 Room dimensions 1.0 x 1301.0 ft 5 Room area 1301.0 ft' Ty Construction U-value Or HTM Area (W) Load Area Load number (Btuh/ft' °F) (Bt or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vd/ L-G 13A-56cs 0.125 n 3.50 2.22 0 0 0 0 IA-clom 1.270 n 35.56 17:90 0 0 0_ 0 III--�� 13A-4ocs 0.143 n 4.00 2.55 144 102 408 260 IA-clom 1.270 n 35.56 24.81 24 0 853 595 �-G 11 IA-clom 13A-5ocs 1.270 0.125 n a 35.56 3.50 24.81 2.22 18 0 0 0 640 0 447 0` yJ 10A-m 1.670 a 46.76 22A3 0 0 0 0 --G W 13A4ocs 0.143 a 4.00 2.55 24 24 96 61 vi 13A4ocs 0.143 s 4.00 2.55 312 249 997 634 1A-clom 1A-clom - 1.270 1.270 s s 35.56 35.51 37.88 37.88 18 24 18, 24 640 853 626 M5 11DO 0.390 s 10.92 11.31 21 21 229 23B V,V L-G 13A-5ocs 0.125 w 3.50 2.22 0 0 0 0 1A-clom 1.270 w 35.56 91.12 0 0 0 0 W �--G 13A-4ocs 9A-c16m 0.143 1,270 w w 4.00 35.56 2.55 91.12 280 8 .272 0 1089 284 692 729 P 12C-Osw 0.091 - 2.55 1.28 304 304 775 390 C 16BA9ad 0.049, - 1.37 2.57 1301' 1301 1785 3347. F 22A-tph 1.358 - 38.02 0.00 1301 95 3612 0 6 c) AED excursion 823 Envelope losstgain 12263 9676 12 a) Infiltration 1746 492 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 2 460 Appliances @ 1200 2 2400 Subtotal (lines 6 to 13) 14010 13028 Less external load 0 0 Less transfer 0 0 Redistribution 8 15 14 Subtotal 14018 13044 15 Duct loads 23% 42% 3234 5510 Total room load 17252 18553 Air required (cfm) 692 810 Printout certified by ACCA to meet all reauirements of Manual J 8th Ed. wr�g htsolFt Right -Suite Residential 6.0.103 RSR31845 2008-Nov-12 09:13:59 .MCP. C:\Program Files\Wrightsoft HVACWutoSave\THIERY RES: PAUL DAVIS REST: REVISION.rrp Calc = MJ8 Page 4 Job M Performed for: THIERY ADDITION 5900 SUNSET BLVD. FT. PIERCE,FL Sheet 1 QUICK CALCS, INC. 317 ST. LUCIE LN. Phone: 772-466-6799 Scale: 1 : 92 Page 1 Right -Suite Residential 6.0.103 RSR31845 2008-Nov-12 09:14:08 )ram Files\Wrightsoft HVAC\... Estimate 2280-R02 Estimate Date 05/30/08 Robert Thiery 5900 Sunset Blvd. Fort Pierce, FL RE: 5900 Sunset Blvd. Fort Pierce, FL Loss Date: 2/6/2008 Claim Number Policv: IfReAoraffon&Remodeling Robert Thiery 5900 Sunset Blvd. Fort Pierce, FL Home: (772) 465-7164 Relative: (772) 380-3790 Jenni The following is a recap of the totals for the above referenced claim. Thank you for allowing us to serve you. Estimate Total 99,790.58 Sincerely Paul Davis Restoration & Remodeing Team License #CG-CA17648 1950 S.W. Biltmore St. Port Saint Lucie, FL 34984 Phn: (772) 340-2080 Fax: (772) 340-2464 Estimate 2280-R02 Estimate Date 05/30/08 Robert Thiery 5900 Sunset Blvd. Fort Pierce, FL RE: 5900 Sunset Blvd. Fort Pierce, FL Loss Date: 2/6/2008 Claim Number Policy: Remodel Only Electrical Task Miscellaneous 1. Provide & Install all Rough Electrical per plan to code. Relocate AC&AHU dedicated circuit. Exterior Walls III aPA L DAMS RestoratronbRemodeling Robert Thiery 5900 Sunset Blvd. Fort Pierce, FL Home: (772) 465-7164 Relative: (772) 380-3790 Jenni Unit 1 LS. Task Quantity Unit Windows 2. Install Small Aluminum Windows - North Elevation 2 UNIT 3. Install Rear Elevation Aluminum Windows 2 UNIT Exterior 4. Provide Rough Carpentry Labor (per man hour 2 men 4 days) 64 HOUR 5. Provide Materials 2 X 4 Wall Framing, 16" O.C. 504 S.F. 6. Install 1/2" Plywood Wall Sheating 504 S.F. 7. Install Tyvec Vapor Barrier 504 S.F. 8. Install Stucco On Metal Lath 504 S.F. 9. Install Double 2 X 12 Headers 21 L.F. 10. Tear down existing Florida Room (per man hour) 24 HOUR HVAC Task Quantity Unit Miscellaneous 11. Remove Existing AJC unit & duct. Install New 3 ton 13 seer Trane unit 1 w/ 10 KW Electric Heat, new flex duct, new refrigerant tubing, & digital t-stat. Paul Davis Restoration & Remodeing Team 1950 S.W. Biltmore St. Port Saint Lucie, FL 34984 LS. License #CG-CA17648 Phn: (772) 340-2080 Fax: (772) 340-2464 1 Estimate 2280-1102 Estimate Date 05/30/08 Linen Closet - Main: L: 4' 4" W: 3' 4" H: 8' 0" oD) 'P AI Resto7ation&Remodeling Task Quantity Unit Ceilings 12. Install 5/8" Drywall Ceiling 14 S.F. 13. Seal Drywall Ceiling 14 S.F. - 14. Install Ceiling Texture 14 S.F. 15. Paint Textured Ceiling, Latex 14 S.F. 16. Install 6 1/2" Batt Insulation, R-19 14 S.F. y 17. Install Light Fixture, Labor Only 1 EACH Walls 18. Install 1/2" Drywall 123 S.F. 19. Seal Drywall 123 S. F. 20. Paint Drywall, Latex 123 S.F. 21. Install Stipple Wall Texture 123 S.F. 22. Install 3 1/2" Batt Wail Insulation (R 11 or 13) 123 S.F. Trim 23. Install Base Trim, FJ, to 3 1/2' 15 L.F. 24. Seal Base Trim 15 L.F. 25. Paint Base Trim, To 3 1/7, Enamel 15 L.F. 26. Install Vinyl -coated Wire Shelving 18 L.F. Floors 27. Install Laminate Wood Floor 14 S.F. - 28. Install Ceramic Tile Floor 15.89 S.F. Master Bedroom Addition Main: L: 18' 0" W: 20' 0" H: 8' 0" Offset: L: 4' 0" W: 7' 0" H: 8' 0" Task Quantity Unit Ceilings 29. Install 5/8" Drywall Ceiling 388 S.F. 30. Seal Drywall Ceiling 388 S.F. 31. Install Ceiling Texture 388 S.F. 32. Paint Textured Ceiling, Latex 388 S.F. 33. Install 6 1/2" Batt Insulation, R-19 388 S.F. 34. Install Ceiling Fan w/Light Kit 1 EACH Walls 35. Install 1/2" Drywall 672 S.F. 36. Seal Drywall 672 S.F. 37. Paint Drywall, Latex 672 S. F. 38. Install Stipple Wall Texture 672 S.F. 39. Install 3 1/2" Batt Wall Insulation (R-11 or 13) 672 S.F. Trim 40. Install Base Trim, FJ, to 3 1/2" 84 L.F. _41. Seal Base Trim 84 L.F. 42. Paint Base Trim, To 3 1/2", Enamel 84 L.F. Doors Paul Davis Restoration & Remodeing Team License #CG-CAI7648 1950 S.W. Biltmore St. Port Saint Lucie, FL 34984 Phn: (T72) 340-2080 Fax: (772) 340-2464 2 N'PAUL DAMS Estimate 2280-I102 Restoration&Remodeling Estimate Date 05/30/08 Master Bedroom Addition continued... 43. Install Prehung Multi -Panel Wood Door Unit w/Hardware 1 UNIT 44. Prime Or Seal Multiple Panel Door and Trim 2 SIDE 45. Paint Panel Wood PH Door and Trim, Latex 2 SIDE 46. Install Frame, Track and Hardware For Interior Pocket Door 4 UNIT 47. Install 1 3/8" Flush Pocket Door Slab and Trim (Lauan Flush) 4 UNIT 48. Prime/seal Pocket Door and Trim 8 SIDE 49. Paint Pocket Door and Trim, Enamel 8 SIDE - 50. Install Custom Exterior French Door per plan 1 UNIT Floors 51. Install Laminate Wood Floor 426.8 S.F. Master Closet Main: L: 3' 11" W: 6' 8" H: 8' 0" Task Quantitv Unit Ceilings 52. Install 5/8" Drywall Ceiling 26 S.F. 53. Seal Drywall Ceiling 26 S.F. 54. Install Ceiling Texture 26 S.F. 55. Paint Textured Ceiling, Latex 26 S.F. 56. Install 6 1/2" Batt Insulation, R-19 26 S.F. 57. Install Light Fixture 1 EACH - Walls - 58. Install 1/2" Drywall 169 S.F. 59. Seal Drywall 169 S.F. 60. Paint Drywall, Latex 169 S.F. 61. Install Stipple Wall Texture 169 S.F. 62. Install 3 1/2" Batt Wall Insulation (R-11 or 13) 169 S.F. Trim 63. Install Base Trim, FJ, to 3 1/2" 21 L.F. 64. Seal Base Trim 21 L. F. 65. Paint Base Trim, To 3 1/2", Enamel 21 L.F. 66. Install Vinyl -coated Wire Shelving 14 L.F. Floors 67. Install Laminate Wood Floor 26 S.F. Miscellaneous Task Quantity Unit Miscellaneous 68. Landscaping - Tree removal as needed to build & sod replacement as 1 L.S. need to cover new drain field & septic. Paul Davis Restoration & Remodeing Team 1950 S.W. Bil more St. Port Saint Lucie, FL 34984 License #CG-CAI7648 Phn: (772) 340-2080 Fax: (772) 340-2464 Estimate 2280-1102 Estimate Date 05/30/08 Permits & Inspections a 'PAUL DAMS Res torat [on &Remodeling - Task Quantity Unit Miscellaneous 69. Secure Permits, License, and Inspections (Allowance unit determined) 1 L.S. Roofing fs Task Quantity Unit Roof 70. Install Standard Grade Fiberglass Roof Shingles (Waste Added, All 9 EACH Inclusive) 71. Install 1/2" CDX Plywood Roof Decking, Waste Added 900 S.F. 72. Straps & J-Bolts Material Allowance 1 EACH 73. Install Roof Trusses by hand and Strap to Code 16 HOUR 74. Provide Roof Trusses per Plan - Material Only 1 EACH Rough Plumbing • Task Quantity Unit Miscellaneous 75. Install all rough plumbing to Plan including hooking into existing hot an 1 LS. cold supply lines_ Septic Task Quantity Unit Miscellaneous 76. 500 sf new Drain Field, 300 gallon cat 3 poly tank w/ pump & high 1 L.S. water alarm. Shower Area Main: L: 5' 5" W: 6' 0" H: 8' 0" Task Quantity Unit Ceilings 77. Install 1/2" Water Resistant Drywall Ceiling 32.5 S.F. 78. Install Mastic Set Ceramic Tile - does not include Green Board 35.75 S.F. Walls 79. Install Water Resistant Drywall, Unfinished 182.67 S.F. 80. Install Mastic Set Ceramic Tile 200.94 S.F. Plumbing Paul Davis Restoration & Remodeing Team License #CG-CAI7648 1950 S.W. Biltmore St. Port Saint Lucie, FL 34984 Phn: (772) 340-2080 Fax. (772) 340-2464 4 Estimate 2280-R02 Estimate Date 05/30/08 Shower Area continued... 81. Install Adjustable Shower Head Slab/Foundation Task Exterior 82. Install New Slab for Addition / All inclusive 83. Additional width to driveway 84. Install 10x6 Patio Landing & 36" walkway to front driveway 85. Concrete walk to front door I D)'PAUL DAWS �"' Resto�atronSaRemadeJing 1 EACH 486 1 1 1 Unit S.F. L.S. L.S. S.F. Toilet Area Main: L: 6' 8" W: 6' 0" H: 8' 0" Task Quantity Unit Ceilings 86. Install 5/8" Drywall Ceiling 40 S.F. 87. Seal Drywall Ceiling 40 S.F. 88. Install Ceiling Texture 40 S.F. 89. Paint Textured Ceiling, Latex 40 S.F. 90. Install 6 1/2" Batt Insulation, R-19 40 S.F. Walls 91. Install 1/2" Drywall 203 S.F. 92. Seal Drywall 203 S.F. 93. Paint Drywall, Latex 203 S.F. 94. Install Stipple Wall Texture 203 S.F. 95. Install 3 1/2" Batt Wall Insulation (R-11 or 13) 203 S.F. Trim 96. Install Base Trim, FJ, to 3 1/2" 25 L.F. 97. Seal Base Trim 25 L.F. 98. Paint Base Trim, To 3 1/2", Enamel 25 L.F. Floors 99. Install Ceramic Tile Floor 44 S.F. Plumbing 100. Install Commode 1 EACH !Vanity Area Main: L: 4' 11" W: 6' 0" H: 8' 0" Task Quantity Unit Ceilings 101. Install 5/8" Drywall Ceiling 30 S.F. f 02. Seal Drywall Ceiling 30 S.F. 103. Install Ceiling Texture 30 S.F. 104. Paint Textured Ceiling, Latex 30 S.F. Paul Davis Restoration & Remodeing Team License #CG-CA17648 1950 S.W. Biltmore St. Port Saint Lucie, FL 34984 Phn: (772) 340-2080 Fax: (772) 340-2464 5 , . . LIEstimate M'Restoratfon&Remodehng 2280-R02 Estimate Date 05/30/08 Vanity Area continued... _ 105. Install 6 1/2" Batt Insulation, R-19 30 S.F. Walls 106. Install 1/2" Drywall 175 S.F. 107. Seal Drywall 175 S.F. 108. Paint Drywall, Latex 175 S.F. 109. Install Stipple Wall Texture 175 S.F. 110. Install 3 1/2" Batt Wall Insulation (R-11 or 13) 175 S.F. ` Trim 111. Install Base Trim, FJ, to 3 1/2" 22 L.F. 112. Seal Base Trim 22 L.F. ` 113. Paint Base Trim, To 3 1/2", Enamel 22 L.F. 114. Install Mirrored Medicine Cabinet-14'SQ2" 1 EACH Cabinets 115. Install Ceramic Top and Splash 4.91 L.F. 116. Install Mica Vanity 2.5 L.F. Plumbing 117. Install Sink 2 EACH Upgrade to Concrete Block Task Quantity Unit Miscellaneous 118. Upgrade Slab to Carry Concrete Block Walls 1 LS. ` 119. Upgrade charge to build as Concrete Block 1 LS. Karl Moore Dated Robert Thiery This is a standard estimate disclaimer to be printed at the bottom of an estimate. Paul Davis Restoration & Remodeing Team 1950 S.W. Biltmore St. Port Saint Lucie, FL 34984 6 Estimate Total 99,790.58 Dated License #CG-CA17648 Phn: (772) 340-2080 Fax: (772) 340-2464 0 0 il- Pk—U-nalso 8w o soouawild saaa) s cu ca liddlU NVW WJs NOIMs Klu*l lymwmum'-O. -II)fll 'is I P-4' ,, 4'-6' f NEW GONSTRUGI � Nq+Fac4r P STATE OF FLORIDA 4 J5�Zt- DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT FOR: OSTDS Repair PERMIT #: 56-SF-946174 APPLICATION #: AP887721 DATE PAID: 07/08/2008 FEE PAID: $55.00 RECEIPT #: 56-PID-10459 DOCUMENT . #: PR744475 APPLICANT: Robert Thiery PROPERTY ADDRESS: 5900 Sunset Blvd FORT PIERCE, FL 34982 LOT: 19 BLOCK: 65 SUBDIVISION: Indian River Estates PROPERTY ID #: 342060904970002 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR, ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID, ISSUANCE - OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND'SPECIFICATIONS r T [ 900 ] GALLONS / GPD Seotic CAPACITY A [ 0 ] .GALLONS / GPD CAPACITY { N [ 0 ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ 300 ] GALLONS DOSING TANK CAPACITY [75.00 ]GALLONS @[. 4 ]DOSES PER 24 HRS #Pumps [ 1 ] D [ 625 ] SQUARE FEET SYSTEM R [ 0 ] SQUARE FEET SYSTEM A TYPE SYSTEM: [X] STANDARD [ ] FILLED [] MOUND [ ] I CONFIGURATION: [X] TRENCH [ ] BED [ ] N F LOCATION OF BENCHMARK: Nail in C/L of Road C/L of lot I ELEVATION OF PROPOSED SYSTEM SITE [ 14.001[ INCHES FT ][ABOVE BELOW ]BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 10.00][ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT L D FILL REQUIRED: [ 0.001 INCHES EXCAVATION REQUIRED: r 1 iNCHFs 0 T H E R Performing Lift Dosing. Pumps must be certified as suitable for distributing sewage effluent. Install in accordance with s. 64E-6.013(3)(f), FAC. Guttering will be required. Pump and alarm must be mounted and working at time of inspection. SLCDOH recomends contractor to place pvc pipe with holes pointed toward top of infiltrator units to diffuse effluant. SPECIFICATIONS BY: John C Hanson TITLE. Environmental Specialist II APPROVED BY: S ' 17L.�ITi�E: Environmental Specialist II St. Lucie CHD John C Hanso DATE ISSUED: 07/10/2008 EXPIRATION DATE: 10/08/2008 11,14016, 10/97 (Previous Editions May Be Used) v 1.! 4 Page 1 of 3 STATE OF FLORIDA APPLICATION # APt3237;21 DEPARTMENT OF HEALTH PERMIT # 56-SF-946174 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION DOCUMENT # SE761582 'APPLICANT: Robert Thiery CONTRACTOR / AGENT: Meeks Plumbling Inc LOT: 19 BLOCK: 65 SUBDIVISION: Indian River Estates ID#: 342060904970002 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL C LETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 0.23 ACRES TOTAL ESTIMATED SEWAGE FLOW: 300 GALLONS PER DAY [ RESIDENCES -TABLET / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 575.01 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 2480.00 SQFT UNOBSTRUCTED AREA REQUIRED: 667.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: Nail in C/L of Road C/L of lot ELEVATION OF PROPOSED SYSTEM SITE 14.00 [ INCHES / FT ] [ ABOVE / BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: n/a FT DITCHES/SWALES: n/a FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: n/a FT LIMITED USE: We FT PRIVATE: 75 FT NON -POTABLE: 50 FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 5 FT POTABLE WATER LINES: n/a FT 1SITE SUBJECT TO FREQUENT FLOODING? [ ]YES Ex ]NO 10 YEAR FLOODING? [ ]YES [X]NO]: 0 YEAR FLOOD ELEVATION FOR SITE: FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD �UIL PROFILE INFORMATION SITE 1 USDA SOIL SERIES:Waveland fine sand Munsell WColor Texture Depth 1 OYR 4/1 _ Fine Sand 0 To 4 10YR 5/4 Fine Sand 4 To 10 1 OYR 5/1 Fine Sand 10 To 18 10YR 6/1 Fine Sand 18 To 47 10YR 3/1 Spodic Material 47 To 49 10YR 3/1 Refusal 49 To 72 USDA SOIL SERIES:Waveland fine sand Munsell #/Color Texture Depth I OYR 4/1 _ Fine Sand 0 To 4 10YR 5/4 Fine Sand 4 To 10 10YR 5/1 Fine Sand 10 To 18 10YR 6/1 Fine Sand 18 To 47 1 OYR 3/1 Spodic Material 47 To 49 10YR 3/1 Refusal 49 To 72 OBSERVED WATER TABLE: 36.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 32 INCHES [ ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION:. [ ]YES [X]NO MOTTLING: [ ]YES [X]NO DEPTH: INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Fine Sand DEPTH OF EXCAVATION: INCHES DRAINFIELD CONFIGURATION: [X ] TRENCH [ ] BED [ .] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA Hanson, John (Title: Environmental Specialist II) DATE: 07/09/2008 DH 4015, 09/2006 (Previous Editions May Be Used) Page 3 of 4 AP837721 EI09a6174 v 1.0.2 STATE OF FLORIDA FOR HEALTH DEPT. USE ONLY /i?r�rTSa DEPARTMENT OF HEALTH PERMIT #: sr— L/- r OI3STTE SEWAGE TREATMENT AND DISPOSAL SYSTEM DATE PAID: ra, APPLICATION FOR CONSTRUCTION PERMIT FEE PAID: V BLDG. #: APPLICATION FOR: [ ] New System [S j Repair [ J Existing System [ ] Holding Tank. [ ] Temp./Exper.System [ J Abandonment [ ] Other (Specify): APPLICANT: ,p � hfL'� TELEPHONE: 772) V,4-g, �I z y, AGENT: TELEPHONE:(] 72 • -FAX;(772 ,_q - 74 41-7 MAILING ADDRESS: PROPERTY INFORMATION: s`S-ss C'TY: li/i!oe,J P�' STATE: p6L ZEE): K?yl 7 LOT: BLOCK: UNIT: Q S� SUBDMSION: , tgi��v,Ql�at C' ims PLATTED: PROPERTY ID #: 3 yc;t- L 6i_ t..Vg-/- Oc-,o . -> ZONING: _ I/11+i OR EQUIVALENT: [ Y PROPERTY SIZE: ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC jam] <=2000 GPD [ ] >2000 GPD IS SEWER AVAILABLE AS PER 381.0065, FS: [ Y DISTANCE TO SEWER: FT PROPERTY STREET ADDRESS: io0 Sv,v.Se BCVp,f_ Pe&G� rc _ 3Li lf2 DIRECTIONS TO PROPERTY: U , S . 1 'fa !f&4 5;'rReeT" j'V1? 0-) OLL40 Uek) NEAREST CROSS STREET:BUILDING USE: [ ] RESIDENTIAL [ ] COMMERCIAL LOCATION OF.SYSTEM: ��,a�0 AJ,E, (i.e. front, rear, SE, NW, etc.) Unit Type of Establishment # Bedrooms Sq.Ft. Living Area # Persons [ ] Floor/Equipment Drains [ ] Other (specify) Commercial/Institutional System Design Table 1, 64E-6, FAC NOTE- Applicant affirms thatthe above �s trueto the best of itts/hr lazawledge acid that the ST3SJECT'R©'ERTX HAS °BEEN CLEARED of underbrush {fQr new systems) and is ready for mspectiou Additional site visti ane �ubleci to' DSO flQ I HAVE READ THE NOTICE TO ALL CONTRACTORS AND I UNDERSTAND AND AGREE IT IS MY RESPONSIBILITY THAT THE BU ELDING SITE IS DEVELOPED AS PER THE APPROVED SITE PLAN AND ONSITE SEWAGE DISPOSAL SYSTEM PERMIT CONDITIONS. p p SIGNATURE: TITLE:DATE: Form 4015 10/9 revious Editions May Be Used) Fees are Non -Refundable and Non -Transferable �•3zYa ' y. M, —ry, ,� 3sx3JIz/szzla r [ ] xT1r� pT� a i 1a fi m [ ] oxlxuYa [ ] - t _ Slom [ ] 3OxKId3�IIY [ ] S'IIOs [ ] =3a / olsYa [ ] '3 '9-3P9 'T 3zSYZ &e ] HZlVf4 a2mszm4 [ ] 'LVIOHM'mo [ ] oIlsma ['Y ] _ 3ZsY4 3o. anx 'vluzxnm 'rmoixiaav/sxw dMMVEI oxlSMIM- mou o no MWA3S a.vO'IuzO OI7nYuam I ] 30 sun [ ] - xx-affdoud JxldOZS _[ ] = SxOIZIa zood [ ] smmxonms eta [ ] m no a'zm mo-iff 3JYM3s azxvmZs3 -aa9 am rrOlsVrssxl mzsxs [ 1-1. b ! m:r'V iuo3N2 ZUYd3u cm 3unzIY3 %IIZS r I / m%ow ] Smolu gam 'Otuxsnm OZ xOIZfi'I32t xI mzsxs aSsoa [ ] mzsxs xZIAvw [ ] [ ] �zia a �ZOa 3O xOIXVAs XOH-a i - ] a3a • [ 7 Hox3uz =xOlzYMD:rHxc [ ] CHOCS4 [ ] a3TII3 [ ] QUYaxfrss [ ] R :sKorsxszuua [ ] Smomm 3o -ox mmsxs ' sxs 30 Hu X f :srtorsx3wza 7 s3rMxUdo -ox- azm Samos [ ;a3zsxs az3lamma x�xa z� zwlws [ C `:7j 5 7 7ZIs `IYsoasra =OCT 1 `=:Qz3I3DLIY2ta iDNxxsIX3 3o-Saxx* _ xolr xwm gm CURLDI�-a ONXISIX swa p_ mqx Ssmusna _ HOXDVEZNOO a2isNxoI7 30 ' a3z'I1orSsxl [ 3JIA3a 2i'3yzI3 LT, R%TJIO / 3JIASa Mixo3'733a SaPIOS ] 'a3I3Ioads SBPM-IQA mm r3AYH x0 fxia.m' • axY 4� '�3i s3mm aszox zAoHFI mar.. .T.wemam a3'733iig -ammarI . XMS Jxlsoa SHOTIYO -� aN3J3'I 2IOZa3: umRa asyses SHOT M [ ] Mm. wI my aao/xtd m olsa3s SHOTI M [ ] : aNSOM MY aaJ/XNYZ. oIsass Sxorim 0 b ] mollvmoa& xm f)Nlzsaxs ' 3orAZi3s ZYso3SIa' 3JYZd3S a3,ZZIMSCI V MHa 'e2zj. z H *ZZY :CIO Moz3H 1QOIZiiJIrTIZ2i3D xAIYZ S;L3zaHIOO s sl 3ze+TOIzaaY TIY' PzwIdm3 'S&mmP Q-agyynwns rxw 7S aNK xolS 'id052i3d-a3I3IS2i3J 2i3giZ0 2i0 ?ioznY2iZNoo xNfrz oIsd3s '33xOTdFI3 ,SNSL2iKa3a-:-dSSxIJx3 a3iIns1932I YQI2io73 xe QSZ3zaFIOO 3H os :Alams - - _ . (� : soz xoz3Yumoo XOIMMWA3 ?IIYd3u MZSxS aNY NxzsxS JxIZSIX3 PMSxS 'IYSOcisIa aNK J.mamvzm 3JYM3S 3ZISAtO # ximaa HIAWZ i .90 ZN3Fi IMINa Yaluo'z3 jo 3ZYZS REPAIR PERMIT SITE PLAN g yrSO ' I s sfr Neu p • w A S— 77-404 ' r a - — — • � Gay' ` ^ � —_- . - ._ �_�_ � . .- : spa � -- -• .- . i {dvc:e /1 M. Please check [ ] when completed on site plan: [ �] Street name and north arrow indicator I -] Lot dimensions (note if.adjacent lots are vacant) C`r j Building sethack at OSTDS area V< ] Driveways [ ] Pool Location of existing tank and drainfi 1 1 Other Siabs C C ] Location of repair C �, Dimensions of I ] 7'unob�ssncteca_rea_on Sx C I All wells with setbacks indicated within 75 feet of the site [� j Trees in OSTDS area St. Lucie. County Building and Zoning Departmen 2300 Virginia Avenue Fort Pierce, FL 34982 FILE 772-462-1553 Design Certification for Wind Load Compliance This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (pkovided that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For fi rther assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. Project Name t o . zt _ �.1 Street Address Permit Number Occupancy Type Construction TTTe Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. . -Design Parameters and Assumptions Used: (Please check or complete the appropriate box.) 1. Florida Building Code 2004 Edition ✓ ASCE 7- 0 Inclusive of 2006 and 2007 revisions. 2. Building Design is (check one) Enclosed '� Partially Enclosed Olen Building 3. Building Height: 4. Wind Speed Used in Building Design: X0 3 second gust 5. Wind Exposure Classification (refer to exposure tables in Building Code identified in Line #1): 6. Average Wind Velocity Pressure on Exterior Faces of Structure 3' PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure PSF 8. Importance/Use Factor (obtain from Building Code): 40 9. Loads: Floor �S(A PSF RooVdead PSF RooVfive � PSF 10. Were Shear Walls Considered for Structure (check one): Yes '� No if No, attach explanation) 11. Is a Continuous Load Path Provided (check one): Yes 1/ No (if No, attach explanation) 12. Are Component and Cladding Detail Provided (check one): Yes No (if No, attach explanation) 13. Minimum Soil Bearing Pressure: ��a PSF As witnessed by my seal, I hereby certify that the information included with this certifacatiori'is &ne,and correct, to the best of my knowledge and belief. ._ ~ ' :-Name: � Certification #: e..] Design Firm: S`i7(6 rti;�r2t✓(p'o�r�� / Date: > b - Si;CCDV'Fo'. ' # 20=00' Product Review Affidavit St Lucie County, Public Works Department / Code Compliance Division The following products will be installed in the structure located at Building Permit # Owners Name Contractor Owner's Address, Contractor's Address Product *Product Rated Design Pressures Manufacture Model Number Method of Attachment Windows * Fill in the rated wind design pressures listed by the manufacture for each product listed lst Choice e'aICz -2 0 2nd Choice (ir.,pr bic) � Fixed Glass Isf Choice 2nd Choice (ir.PPcwek) Glass (other) Butt Glass Glass Block Sliding Glass Doors I st Choice 2nd Choice (;r.,,,cow.) Swing Type Doors 1st Choice •,-A 5-0 U 2nd Choice (... oi.. Overhead Garage Doors 1st Choice 2nd Choice c;r,wkw.) Roofing Material Asphalt/Fiberglass. 0P 7 ff40&VO4tJ �L Metal P%��jT% Other Shutters Choice -� S',J`jj13i7 s o63 r'�v 1t1 Lily; (y ti b/L I have reviewed the above components and cladding and have approved their:i9e`in..06 structrr-e and provide adequate resistance to the wind "loads and forces specified by current;c, provisions. Name: _ "-rl Signature -,J\� � , j , ``Seal (FBC 106.1) Design Firm 15-1-1 k Cert. NO. 7-00 Date: Rev1219105timp '1 MIAMI•D�ADE � MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 372-6339 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/buildiggcode TRACO Security Windows & Doors, Inc. 71 Progress Avenue Cranberry Township, PA 16066 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by.Miami-Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In -Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or, material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may.. immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA;reserves3 , r'11ight, to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product -or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and -has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone. DESCRIPTION: Series "Coastal-240" Aluminum Single Dung Window -- L.M.I. APPROVAL DOCUMENT: Drawing No. 05-TRA-0003, titled "Coastal-240 Single Hung Window Large Missile Impact Resistant", sheets 1 through 3 of 3, prepared by Frank L. Bennardo, P.E. Consulting Engineer, dated 01/13/2003 with revision "3" on 10/23/2006, signed and sealed and dated 10/08/2007 by Frank L. Bennardo, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. _MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there'has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the' materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and supersedes NOA # 05-0930.03 and consists of this page 1 and evidence pages E-1 and E-2 as well as the approval document mentioned above. The submitted documentation was reviewed by Jaime D. Gascon, P.E. NOA No 06-1121.14 Expiration Date: March 17, 2013 Approval Date: November 22, 2007 Page 1 TRACO Security Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. 05-TRA-0003, titled "Coastal-240 Single Hung Window Large Missile Impact Resistant", sheets 1 through 3 of 3, prepared by Frank L. Bennardo, P.E. Consulting Engineer, dated 01/13/2003 with revision "3" on 10/23/2006, signed and sealed and dated 10/08/2007 by Frank L. Bennardo, P.E. B. TESTS 1. Test reports on 1) Air Infiltration Test, PA 202-94 2) Uniform Static Air Pressure Test, Loading PA 202-94 3) Water Resistance Test, PA 202-94 4) Large Missile Impact Test, PA 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Resistance; PA 202-94 along with marked -up drawings and installation diagram of an aluminum single hung window, prepared by American Test Lab. of South Florida, Test Report No. ATL-0713.01-99, dated 10/07/1999, signed and sealed by William R. Mehner, P.E. and Henry Hattem, P.E. With addendum letter dated 2/23/2000, signed and sealed by William R. Menner, P.E. (Submitted under NOA# 05-0930.03) 2. Test reports on 1) Air Infiltration Test, PA 202-94 2) Uniform Static Air Pressure Test, Loading PA 202-94 3) Water Resistance Test, -PA 202-94 4) Large Missile Impact Test, PA 201-94 5) Cyclic Wind Pressure Loading, PA 203-94 6) Forced Entry Resistance, PA 202-94 along with marked -up drawings and installation diagram of an aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-2363, dated July 22, 1999, signed and sealed by Jose D. Mitrani, P.E. (Submitted under NOA# 05-0930.03) C. CALCULATIONS: 1. Revised Anchor calculations and structural analysis, prepared by Frank L. Bennardo, P.E. Consulting Engineer dated 10/08/2007, signed and sealed by Frank L. Bennardo, P.E. Complies with ASTM E 1300-98/ 02 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO).. Jaime D. Gascon, P.E. Chief, Product Control Divison NOA No 06-1121.14 Expiration Date: March 17, 2013 Approval Date: November 22, 2007 E-1 TRACO Security Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATION: 1. Notice of Acceptance No. 04-0721.01 issued to Elco Industries, Inc. for "Tapcon Concrete Anchors" dated 03/09/2006 expiring on 01/08/2011. 2. . Notice of Acceptance No. 06-0216.06 issued to Solutia Inc. for their "Saflex IIIG Clear or colored.Interlayer" dated 05/04/2006, expiring on 05/2112011. 3. Notice of Acceptance No. 05-1208,02 issued to E. I. DuPont DeNemours for "Laminated Glass with Butacite® as Interlayer" dated 01/06/2006, expiring on 12/11/2010. E. STATEMENTS: 1. Statement letter of conformance and no financial interest 09/02/2005, signed and sealed by Frank L. Bennardo, P.E. (Submitted under NOA# 05-0930.03) G. OTHER 1. Notice of Acceptance No. 05-0930.03, issued to TRACO Security Windows & Doors, Inc. for their Series "Coastal-240" Aluminum Single Hung Window — Impact Resistant, approved on 03/23/2006 and expiring on 03/17/2008. Jaime D. Gascon, P.E. Chief, Product Control Divison NOA No 06.1121.14 Expiration Date: March 17, 2013 Approval Date: November 22, 2007 E-2 6 1/4- MAX. AT HEAD/SILL CORNERS COASTAL-240 SINGLE HUNG WINDOW LARGE MISSILE IMPACT RESISTANT 47 7/8' D.L.O. (FIX. LITE) 9" MAX. AT HEAD/SILL F1 A SAWM#", AL LAM S D B i C 9' MAX. AT HEAD/SILL 47 1/8- D.L.O. (VENT) 50 1/4- VENTWIDTH 53% MAX. WINDOW WIDTH TYPICAL ELEVATION 1/8' ANN. GLASS .090 INTERLAYER SAFLEX PVB 4 1/8' ANN. GLASS SILICONE DOW CORNING 1199 OR GE STRUCTURAL SILICONE (GE RGS770D) 17 z zm m i yguJ g 13 12 5/16' OVERALL LAM. ANN. GLASS LAMINATED BY'GUARDLAN' GLAZING OPTIONS HEAD/SILL ANCHORS: 11 JAMBANCHORS: I 6Y," MAX FROM CORNERS AND BALANCE @ 9' MAX ON CENTER, AS SHOWN ON TYPICAL ELEVATION: T JAMB 6' MAX ACO.ERS 5' MAX OW AT MTG RAIL) SEE JAMB ANCHOR SCHEDULE FOR NUMBER OF ANCHORS AT MEETING RAIL LOCATION B. MAX AT IAMBS u SEE JAMB ANCHOR SCHEO FOR NO. OF ANCHORS PER JAMB MAX AT JAMB CORNERS LANCHOR LOCATIONS TYPICAL BOTH SIDES WINDOW DIMS. WIDTH HEIGHT 19 1/8" 261/2' 2 37" 6" 53 1/8" 19 1/8" 26 1/2" 37" 38-3/8' 53 1/8" 19 1/8" 26 1/<" 50-5/8- 37" 261/2" 57" B 2 37" 8 2 531/'3" 9 3 19 1/8" 8 2 261/2" 63' 8 2 37" 8 2 53 1/8" 10 4 19 1/8" 10 2 26 1,/.I" 74-1/4' 10 2 37" 10 2 53 1/4" 1 10 4 ( 'TOTAL' INDICATES TOTAL NUMBER OF 'J ANCHORS AT EACH JAMB (INCLUDES "MTG RAIL' ANCHORS). 8" MAX SPACING INCORPORATED INTO TOTAL NUMBER OF ANCHORS. Q 'MTG RAIL' INDICATES NUMBER OF ANCHORS AT HORIZONTAL MEETING RAIL ENDS AT JAMBS (EACH END) ANN. GLASS INTERLAYER SAFLEX PVB ANN. GLASS DOW CORNING 1199 OR GE STRUCTURAL SILICONE (GE RGS7700) 5/16'.OVERALL LAM. ANN. GLASS LAMINATED BY TEMPGLASS' MAX DESIGN PRESSURE +62 / -62 PSF GENERAL NOTES: 1. THE SYSTEM DESCRIBED HEREIN HAS BEEN DESIGNED AND TESTED IN ACCORDANCE WITH THE 2004 FLORIDA BUILDING CODE, HIGH VELOCITY HURRICANE ZONES, MIAMI-DADE COUNTY PROTOCOLS TAS 201, 202 & 203, AND ASTM E 1300-98. 2. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM, WIND LOAD DURATION FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN. 3. POSITIVE AND NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED BY OTHERS ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. 4. THE SYSTEM DETAILED HEREIN HAS BEEN TESTED PER MIAMI-DADE COUNTY PROTOCOLS TAS-201, TAS-202, & TAS-203 AS REFERENCED IN TEST REPORTS #0713.01-99 BY AMERICAN TEST LAB (ATL), #2363 BY FENESTRATION TESTING LABORATORY (FTL) AND &T188-06 BY FARABAUGH ENGINEERING &TESTING, INC (FET). MULTIPLE UNITS MUST BE INSTALLED USING MIAMI-DADE COUNTY BCCO-APPROVED STRUCTURAL MULLIONS. S. THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT FROM THE CONDITIONS DETAILED HEREIN, ALICENSED ENGINEER OR REGISTERED ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. 6. PERMIT HOLDER SHALL VERIFY THE ADEQUACY OF THE EXISTING STRUCTURE TO WITHSTAND SUPERIMPOSED LOADS. WOOD BUCKS (BY OTHERS) SHALL BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE EXISTING STRUCTURE. 7. PANELS GLAZED WITH 5/16" LAMINATED GLASS (BY 'GUARDIAN' OR'TEMPGLASS') ARE LARGE MISSILE IMPACT RESISTANT AND DO NOT REQUIRE IMPACT RESISTANT SHUTTERS. 8. ANCHORS SHALL BE INSTALLED AS LISTED PER MANUFACTURER'S SPECIFICATIONS AND SPACED AS SHOWN HEREIN. ANCHOR EMBEDMENT TO BASE MATERIAL EXCLUDES STUCCO OR WALL DRESSING. 9. ALL STEEL IN CONTACT WITH ALUMINUM SHALL BE PAINTED OR PLATED. LARGE MISSILE IMPACT RESISTANT WINDOWS SHUTTERS NOT REQUIRED TYPICAL ANCHORS: 1. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2. ANCHOR EMBEDMENT SHALL BE INTO BASE MATERIAL, EXCLUDING STUCCO OR OTHER WALL FINISH. 3. BASE MATERIAL SHALL BE WOOD (G=0.55 OR GREATER SPECIFIC GRAVITY), GROUT -FILLED BLOCK (MIN 1500 psi COMPRESSIVE STRENGTH FOR GROUT). OR CONCRETE (MIN 3000 PSI). 4. SE; EXTERIOR ELEVATIONS FOR ANCHOR LOCATIONS AND SPACING. S. ENSURE MINIMUM OF 2-1/2- EDGE DISTANCE FOR ALL ANCHORS INTO GROUT -FILLED BLOCK (MIN 1500 PSI) OR CONCRETE IN 3000 PSI), AND MINIMUM OF 1-1/2' EDGE DISTANCE FOR ALL WOOD ANCHORS. 6. ANCHOR OPTIONS FOR INSTALLATION ARE AS FOLLOWS: TO 2X WOOD BUCK OR WOOD STRUCTURE #14 WOOD SCREW OR 1/4" TAPCONS (ITW OR ELCO) WITH 1-1/2" MINIMUM EMBEDMENT. TO CONC (MIN 3000 PSI) OR GROUT -FILLED BLOCK (MIN 1500 PSI) (DIRECTLY OR THRU 1X OR ZX WOOD BUCK) 114" TAPCONS (ITW OR ELCO) WITH 1-3/4" MINIMUM EMBEDMENT TO CONC (MIN 3000 PSI) OR GROUT -FILLED BLOCK (MIN 1500 PSI). - SEALANTS: FRAME AND VENT CORNERS SEALED WITH SCHNEE MOREHEAD 5504. 2 it o v iF O WW S a W¢ C O 7"XC W FO Z m LL 0 ca F N O m W O �j W9 Y U) 3LL 1L� ZZ NOW 3� *o mW� D- () 0 ao 05-TRA-0003 P DDlii:-i PIJVI;ED DESCRIPTION! a cumP;Y!-G with the Florida BuiiEing Code Acceptarcc ND 06-1121.1 Fxpi ate / 3 �•1 By G INiami de Product Control 'LII Division !Y O tLU W I TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. FOR SPACING 1BY OR 2BY WOOD BUCK ITEM NO. PART NUMBER QUANTITY DESCRIPTION MATERIAL MANF./SUPPLIERJREMARKS 1 050-00-572 1 FRAME HEAD 6063-T6 2 050-DO-308 1 FRAME SILL 6063-T5 - 3 050-00.586 2 FRAME JAMB 6063-TS 4 051-00-571 1 VENT TOP 6063-T6 5 051-00-548 1 VENT BOTTOM 6063-T5 - 6 050-OD-570 2 VENT SIDE '6063-T6 _ 7 051.OD-573 I 1 FIXED MEETING RAIL 6063-T6 - 8 050.00-569 4/LITE GLASS STOP 6063-T6 ' 9 012-00-835 AS REQD. FRAME ASSEMBLY SCREW S8 X 1' PHPH SMS 30 012-00-835 AS REQD. VENT ASSEMBLY SCREW ?8 X 1' PHPH EMS 11 D46-00.098 AS REQD. W-STRIPPING (FABRIC COATED FOAM) SCHLEGEL Q-LON .375 X .190 12 D46-16-102 12 SETTING BLOCK .10' X .30' X 1-5/9" LONG 5' FROM ENDS B AT MIDSPAN 13 - AS REQD. GLAZING COMPOUND SILICONE DOW 1199 14 007-10-016 2 SWEEP LOCK (AT 6-3/4' FROM ENDS) ZINC CAST MARBOLLO INT. 15 046.16-030 2 BLOCK AND TACKLE BALANCE WINDOW COMPONENTS (5/8' BOX) 16 050-00-718 1 SNAP LATCH 3' LONG W/ SPRING 6063-TS AT MID WIDTH 17 046.06-010' AS REQD. BULB VINYL WIBORG 18 19 20 047-00-015 AS REQD. FIN SEAL PILE AMESBURY 1BOX150 OR EQUIV. 21 012-00-130 4 MTG. RAIL ASSEMBLY SCREW *10 X 1" PHPH SMS 22 05-0127-10 05-0128.16 AS REQD. GLAZING COMPOUND TWO-PART GE STRUCTURAL SILICONE SILICONE GE RGS7700 IBY OR WOOD EXTERIOR TYPICAL ANCHORS P 0DUC7REVISED �: co�n�;7iag with Iha Florida E•sil_"i00 Coda Acccpl��cc No Obi 1 EKpimtion Datc � I O S Miami ode Pra uu Contro Division z 0 0 -W ui U, #'M 6 Z. LL o ZF W O W q K S w W U A W o z Z io < m F O 0 W O J L. c m Q1(0 3LLu LLL� KO OWK LL.0 O�ti 05-TRA-0003 �^2.875 .062 7YP. .J50 1J62 .O7F g 2.458 1 F rBOTTOM VENT TOP -RAIL ;BOTTOM VENT BOTTOM RAIL 1.500 _j .078 .937 I .062 TYP. .750 L ' 6 SASH SIDE RAIL F.1371 .W5,89 2 1�TCH .688 .125 I II .875 h- B LA S STOP &MMUIL FRAME BOTTOM CORNER VENT TOP CORNER VENT BOTTOM CORNER W ID 0 Ili W F°mi Ui O� WLLS tt^S N 2 F5 ZZle U) cm�a 3 rL zZ 0 oW� Fq 0Wci ILU 05-TPA-0003 PAGE6CALE:- �+s tear t':e r1crida FSCRIPTION: Accetc:.m: t.0 - EzpirrinnDcic r 3 By Missode roduct Con 1 Division MIAMI-DADE COUNTY, FLORIDA MIMI®I�►�E METRO-DADE FLAGLER BUILDING COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) www.buildinacodeonline.com JELD-WEN, Inc. 3737 Lakeport Blvd. Klamath Falls, OR. 97601 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone, DESCRIPTION: Series 6-8 Gladiator/E.S. Outswing Steel Door w/wo Sidelites-Non-Impact APPROVAL DOCUMENT: Drawing No. S-2004, titled "6-8 Gladiator/E.S. Outswing Steel Door w/wo Sidelites ", sheets 1 through 8 of 8, dated 07/10/07 and last revised on 05-06-08, prepared by manufacturer, signed and sealed by Joseph R. Evans, P.E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: None. Approved Hurricane Protection Devices, complying w/ FBC, as applicable are required. Limitations: 1. Vent panel is approved with Sin le Door application only. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, -and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 02-1211.10 consists of this page 1 and evidence pages E-1, as well as approval document mentioned above: 'The submitted documentation was reviewed by Ishaq I. Chanda, P.E.. w 1 APPROYED ` U'4a00 NOA No 08-0516.07 Expiration Date: July 12, 2009 Approval Date: July 03, 2008 Page 1 JELD-WEN, Inc. NOTICE OF.ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. S-2004, titled "6-8 Gladiator/E.S. Outswing Steel Door w/wo Sidelites ", sheets 1 through 8 of 8, dated 07/10/07 and last revised on 05-06-08, prepared by manufacturer, signed and sealed by Joseph R. Evans, P.E. B. TESTS (transferred from file # 02-1211.10) 1. Test reports on 1) Air Infiltration Test, per PA 202-94 2) Uniform Static Air Pressure Test, Loading per PA 202-94 3) Water Resistance Test, per PA 202=94 4) Forced Entry Test, per SFBC 3603.2 (b) and PA 202-94 along with marked -up drawings and installation diagram of pairs of outswing glazed residential insulated steel doors with sidelites, prepared by Certified Testing Laboratories, Test Report No. CTLA456W (Addendum), dated May 23, 2000, signed and sealed by Ramesh Patel, P.E. C. CALCULATIONS 1. Anchor Verification Calculations, dated 05-06708, prepared, signed and sealed by Joseph R. Evans, P.E. 2. Complies with ASTM E1300-98 & -02 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS (transferred from file # 02-1211.10) 1. Tensile Test prepared by Certified Testing Laboratories, Test Report No. CTLA456W, dated September 30, 1999, for steel samples, tested per ASTM E8-93a, signed and sealed -by signed and sealed by Ramesh Patel, P.E 2. Test Report No. ITS499006660-001, prepared by Intertek Testing Services NA, Inc., issued to Jeld- Wen Research and Development, dated April 8, 1999, for samples of foam, tested per ASTM E 84- 94 "Standard Test Methods for Surface Burning Characteristics of Building Materials" and ASTM D 1929-91A "Standard. Test Method for Ignition Properties of Plastics'; signed and sealed by Douglas Keith Tucker, P.E. 3. Notice of Acceptance No. 07-0214.08 issued to ODL for "ODL-Non-Imp HP -Polypropylene Lite-Kit assembly -component approval", expiring on 12/30/2010. 4. Notice of Acceptance No. 07-0801.05 issued to ODL for "HP -Polypropylene High Performance Lite Material -Component Approval"., expiring on 01/17/2011. F. STATEMENTS 1. Statement letter of conformance & no financial interest, dated May 05, 2008, signed and sealed by Joseph R. Evans, P.E. 2. Statement letter of lab compliance, part of above test reports. G. OTHER 1. This renews NOA # 02-1211,10, expiring July 12, 2009. 2. One year conditional Non -Renewable approval. shaq I. Chanda, P.E. Product Control Examiner NOA No 08-0516.07 Expiration Date: July 12, 2009 Approval Date: July 03, 2008 E-1 JELD-VEN® Steel 6A GLADUITOR/ENERGYSAW:R OUISMNG STEEL DOOR W/8 w10 sIDELREs GENERAL NOTES 1. THIS PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT FLORIDA BUILDING CODE (FOC); INCLUDING HVHZ AND HAS BEEN EVALUATED IN ACCORDANCE WITH THE FOLLOWING: -TAS 202-94 2. WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. 3. PRODUCT ANCHORS SHALL BE AS LISTED AND SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 4. IMPACT RESISTANT SHUTTERS REQUIRED FOR DOORS AND SIDELITES. 5. DESIGNED PRESSURE RATING SHALL BE AS FOLLOWS: -SEE DESIGN PRESSURE RATING TABLE SHEET ONE. 6. SIDELTTES ARE AN OPTION AND CAN BE IN A SINGLE OR DOUBLE CONFIGURATION. 7. THIS SYSTEM DOES MEET THE WATER REQUIREMENTS IN &1AMI-DADE COUNTY. , RESIDENTIAL INSULATED STEEL DOOR (Common to all frame conditions) Door Leaf Construction: Face sheets: 24 ga. (0.021 ) minimum thickness, 25 ga. (0.018) galvanized steel A-525 commercial quality - AKDQ per ASTM 620 with yield strength Fy(ove.)=24,600 psi. Core design: Expanded polystyrene with 1.0 to 1.25 lbs. density. Panel Construction: Steel face sheets glued to expanded polystyrene (EPS), with wood rails and laminated veneerd lumber stiles and a wood lock, block reinforcement. Frame Construction: The head jambs and side jambs ringer jointed pine measuring 4.5625" x 1.25. The head and side jambs are mortised, butted and joined using (3) 7/8" x 2" wire staples. The threshold used is an aluminum outswing �bumpfoce measuring 4.625" 1". TARIF OF CONTENTS SHEET # DESCRIPTION 1 COMMON GENERAL NOTES, TYPICAL ELEVATION 2 VERTICAL CROSS SECTIONS 3 HORIZONTAL CROSS SECTIONS 1 3, 2 3, & 3 3 4 HORIZONTAL CROSS SECTIONS 1 4, 2/4 & 3 4 5 ANCHORING LOCATIONS 6 ANCHORING LOCATIONS & DOOR MODELS 7 1 BILL OF MATERIALS & GLAZING DETAILS a I unit UUWUN Iw J 0 i v J DOUBLE DOOR M) 38 PANI 15.5 14" MAX. �FRAMI PANEL WIDTH { { { 21.8175' 5, { MAX. D.L. I { { �( 0 `o 0 4 ' { { a SINGLE DOOR WISIDELITE fOXO) . MAX. 37.5" M E WIDTH AX. OVERALL WIDTH 'r19.625" d MAX. P.L.O. { y N O { n n� MAX. D,O. 6 W SINGLE DOOR ELEVATION (N) DOUBLE DOOR W&IDELITES LOXXO) GLAZED DOOR SHOWN FOR CLARITY OF VIEW (VIEWED INTERIOR) DESIGN PRESSURE RATING WHERE WATER INFILTRATION REQUIREMENT IS NEEDED POSITIVE + 50.0 PSF NEGATIVE - 46.0 PSF PRODUCT RENEWED w complying wllh the Fier]& Bolding Code Aaepteoee Nod$- U V14. 07 EspBfllon ISGa I- �AK� R EVANS, P.E 1 RmOe'Frodnet R.ORMA NO. 4392 Di'mm im V="I wow wA, R no LJow W 0 1- �_J J J lal Mw e � Q In0 o� o � C.D a}S J J to m F 0 o o r o g Ua a sme: NITS DWG. BY: JWJ ax. By. S. Saffell S-2004 I OF 2 5 11 MIN. 2- \z -i lvllhl. N a, 7 z z 12 7 9 Uj m W SEE NOTE J4 Slfr. 3 14 w .0 30 SEE NOTE 'o 26 #5 SHT. 3 20" MIN. 29 29 SKIN EXTERIO FIXED 6 �E 13 .75" GLASS THK. I w ri 27 w 31c; ci .5 MIN. .4 c4 m GLASS THK. OPERABLE 23 rh 15 c4 0 7 0 EMIOR INTERfO .020" MIN. IU SKIN THK. 1.75' MAX. PANEL THK. ai 12 is �2 5/8' MIN. j VERTICAL CROSS—SECTION ,--2 5/8- MIN.--� VERTICAL CROSS—SECT70N 2 2 5/8- ai MIN. F [_.020- MIN. SKIN It z 1.75" MAX. PANEL THK. 27 .5* MAX. GLASS THK.ci INTERIOR �gfQg SEE NOTE 1114 SHT. 3 12 2 5/*e" MIN.-{ 2 5/*e" MIN.-{ ca VERTICAL CROSS-SEC77ON DAM- 07110107 MMUCT RENEWED SCALE NTS EWdUg-.NCode.00-os-19-c-7 DWG. BY: Ad A.w CHK By; S. Saffell RE DRAWING NO.: JYS9H R. EVANS, FLORIDA NO. 4392 S-2004 Dhiebn ull SAW wx lwemffima� — -2 --L .25" MAX v SHIM 23 B EXTERIOR 30 22 •!. •'.• Y 6Y Y :*�• 31 �tF 4 INIEHIOE w b z 29 y F' N SEE NOTE J5 12 °' SHE 3 •o Z .15" MIN N . COUNTERSINK F HORIZONTAL CROSS SECTION 3 AT LATCH JAMB TO BUCK, TYP. 1 1/4' MIN. EMB. NOTES: 1. SPACING FOR #18A IS AS FOLLOWS: FROM TOP DOWN 1", 2 112", 4 5 1/2 .13", 18" & 26". SPACING FROMTHE BOTTOM UP IS THE SAME. 2. ATTACH THE STRIKE PLATE AND THE DEADBOLT PLATE TO THE ASTRAGAL USING A #8 x 2" LG. PHILLIPS FLATHEAD SCREW. 3. SPACING FOR #8 x 2" PHILLIPS FLATHEAD SCREW WHEN ATTACHING THE SIDELITE TO. THE SIDELITE JAMB IS AS FOLLOWS: FROM THE TOP DOWN & BOTTOM UP 6" & 30". 4. SPACING FROM #8 x 1 112 PLASCREW IS AS FOLLOWS FOR SIDELITES & FULL LITES: TOP & BOTTOM; SIDELITE (2) SCREWS 2" IN FROM EACH CORNER. FULL LITES (3) SCREWS 3" IN FROM EACH CORNER, & (1) IN THE CENTER. SIDES FOR BOTH; (6) SCREWS 3.25", 13.75", 26.5", 39.375", 52.0", AND 62.625". 5. SPACING FOR #8 x 1 112 PLASCREW IS AS FOLLOWS FOR THE VENT LITE: TOP & BOTTOM 2.5" IN FROM THE CORNERS & (1) IN THE CENTER SIDES; 3.25" FROM THE TOP CORNER & (3) MORE AT 10.375". ASTRAGAL RETAINING BOLTS 0.31' x 19.25" L 0 TOP 0.31' x 19.25' 0 BOTTOM ALUM. RETAINING SLIDE N 9 SEE NOTE4 16 13 12 o vYi �LQE zd SHT. 3 a D HORIZONTAL CROSS SECTION 3 AT ASTRAGAL. TYR 26 S Y 16 / n EXTEBIOB INTERIOR 29 SEE NOTE J4 SHE J 0 m ca �j m o u1 Z � Uj PQj W w � C SC N �- tl• ig ea Ld 0O En w O �-i w w z D- w Q In O H s z 3 a1 Z {�-- W too\N 2p o o _ 0. a 15" MIN. COUNTERSINK I 1 1/4• MIN. E HORIZON A CROSS SECTIONL 3 AT HINGE JAMB TO BUCK, TYP. 25"--IMAX. EMB. SHIM THK 9 ass ooNo nw� DATE 07 10 07 PRODUcr RENEWED McmPlying With The R dds =-9C"de Ewmtiuee N T4A S�L'O%� Eryln/no� Drte �TG/W / ti. LT / �b �� SCALE. WS DWG. BY. Jwj GNK. V. S. Sof(ell Ho.: AYE; ' • JOSEPH R. EVANS, P.E.DRAWN" FLORIDANO.92 5-2004 SHEET 3 OF 8 Biwa= R. ww At% m =P SEE NOTE #4 SHT. 3 .25" MAX. 6 29 SHIM THK. 4 AT SIDELITE TO HINGE JAMB. TYP. LL Ambtw6Me'h ftm llw, IDiritlon 0 � m CU ca Zoe Wa. Q WU-OOR NOW LJ 8 uj \-j J W y O W N G v S n O W\ �,\ p� gZ ; 3dS m Jt °° \ rn Z <r too oof 0 2 F a N —LE NIS Dwc. BY. JWJ MiK. BY. S. SOffell DRAWING NO.: JOSEPH R. EVANS, P.E 5-2004 FLORIDA NO. 4392 ISO suer mi W m Awc a .v s EET 4 OF 8 L- 6" OR 7 TYP. — Lo �n to to m 00 E D In — — . n 7 —I i E h'-- SINGLE DOOR ANCHORING LOCATIONS (X) VIEWED FROM THE INTERIOR ASTRAGAL STRIKE PLATE (BY IMPERIAL) --L7 j/8 x 2.50' PFH WOOD SCREW4 DETAIL ATTACH ASTRAGAL THROW BOLT STRIKE PLATE TO FRAME AS SHOWN. DETAIL G 4 3°- 3'- 4 rSEE DETAIL F 12. 9' 9' TYP. 6° TYT 9" 6• 4 1 i 3° I 3. 3" TIP. 3. 3" 7 TIP. - Typ 7 Typ - TYR _ 7 - TYR i I ill Inil 3' 6• 3" TYR 3° 6' TyP. 6• 4 1 3' 9' TYP. 3° 9° 9' DOUBLE DOOR W/SIDELTTES ANCHORING LOCATIONS (OXXO) VIEWED FROM THE INTERIOR 0 DETAIL G HINGE DETAIL Z' (j m O to Z0C`3�� W W ,a 3g�& LU^aea ui'o W m M LLi o h J 9 N, W V r�qi OO H z 00 to gz3 0 ME m o �23" � 0 0 a o a PRODUCTRENEWED SCALE: NTS a mmplyingwith the Flork" DWO. Err. JWJ Bolding Code 6[pfrpeon Detee Z �o `7 ` jAtlln�o cmer: S. Saffell DRAWING NO: VY /,+ 1 • R N JO.SEPH R. EVANS. P.E S-2004 FLORIDA NO. 4392 p RAM FAIK a s/m SHFEr 5 OF 8 SEE DETAIL F SHEET 5 — . NL G DOUBLE DOOR ANCHORING LOCATIONS (XX) VIEWED FROM THE INTERIOR 36.0" MAX. 15.25" MAX 4 1/2" 9' 6,W�3 4 1/2" 3" 3" 3'' 3'1 FOT a q TYR MT . TYR TYP. ` � m n G E OR F r-i — 7� TYP. ITT n — TYP. T'P— F- 1 1 3. T 8' 8' r-3. 4 1/2' 6' 3' J. 3' 3" SINGE DOOR W/SIDEI FEES ANCHORING LOCATIONS (OXO) VIEWED FROM THE INTERIOR PANEL WIDTH PANEL WIDTH J = J J J J J i J Ld z o 0 J a J a o J o J O o O x J g J o J J GLAZED DOOR MODELS SIDELITE MODELS �jDo too i Z cr of W W v' Y a N O W LJ O 1 J U.I 0WN z gZ "� m Zo oo��N o0 cook c=ia U K O 0 0 � a PRODUCT RENFWCh SC/LE NTT av mmitlyln& with the Florida e®ldlo¢C d. weceotaam No G�-0 ", ctpFratim Doh _7��yJlTv_l;�j.lod DWG. er: JWJ By; S. Saffell 1S(r• '. L1�A N.f`" FPFI R. EYANS, P.E DRAWING Aabct MRIDA NO. 4392 —2 S004 it m nrr"�nmm SHEET _L or 8 INTERIOR INTERIOR Z[i .5" GLASS ' BITE Y Z .125" INSULATED rA TEMPERED GLASS �•� \ ' 25" AIR SPACE .. _ • •• 27 .125" INSULATED TEMPERED GLASS 25" STEEL SPACER 29 SEE NOTE #4 SHT. 3 GLAZING DETAIL FULL LITE & SIDELITE MATERIAL S q J V a0 IO Z y IO -+ W W KAZ 7 A n W i 1 DOOR WOOD EDGE 1.75' THK. 24GA. .020'MIN. STEEL 2 HEAD JAMB 1 1 4 x 4 9 16 PoNEROSA FINGER JOINTED PINE PINE 3 HINGE JAMB 1 1 4' x 4 6 16' PONDERSOA 1101 JOINTED PINE PINE 4 SlOELITE JAMB 1 1' 4' x 4 9 16' PONDEROSA FINGER JOINTED PINE PINE 5 4' x 4' SUIT HINGE 12 a..097' HAGER STEEL 6 9 X 1' PFH WOOD SCREW HINGE 70 DOOR STEEL 7 3116 RW BUILDEX TAPCON WITH 1 1 4' MIN. EMBEOMENT STEEL 8 10 x 2' PNIWPS FLATHEAD WOOD SCREW STEEL 9 1 4' x 2 1 2' TAPCON STEEL 10 8 x 2 1 4 PMLL FLATHEAD WOOD SCREW STEEL 11 OUTSMNG BUMPER THRESHOLD .050 EXTRUDED ALUM. ALUM. 12 COMPRESSION WEATHERSTRIP SCHLEGEL C-LON COS 650 FOAM 13 FJORUDED ALUMINUM ASTRAGAL BY IMPERIAL ALUM. o W W�i.i p J �� o ow In a N o g Z � _ 3 $1 oo Ul =0 3 0 m °8 a �+ o N d DO o a 14 D 1.67 x 7' WOOD 15 W M RAIL.67' x i' WOOD 16 SIDESR 1.06 ' .065' WOOD 17 NOT USED - 18 8 x 1 2' PANHEAD STEEL 19 16 x 1' PHILLIPS FLATHEAD WOOD SCREW STEEL 20 KWRKSET 400 SERIES KNOB 21 KWIKSET TITAN 700 SERIES DEADBOLT - 22 2x WOOD SUB BUCK WOOD 23 EXPANDED POLYSTYRENE 1.0 to 1.25 lb. DENSITY BY JELD-WEN FOAM 24 NON -COMPRESSION SHIM WOOD 25 WOOD LOCK BLOCK 1.71' x 4.0' x 12.01 WOOD 26 LITE FRAME ODL POLYPROPOLENE I POLYPROP. 27 1 2' OVERALL INSULATED TEMPERED GLASS CLASS LATCH JAMB 1 1 4' X 4 9 16' PoNOEROS4 FINGER JOINTED PINE) 29 8 x 1 1 2' PLASCREW LTTE FRAME -WOOD - STEEL SEE NOTE #5' SHT. 3 GLAZING DETAIL VENT LITE 25" INSULATED MPERED GLASS .5" AIR SPACE i" INSULATED PERED GLASS . PRODUCT RENEWED o xac ..8 with the P1eri fa aeAaixicwx5��/ter Atcephaa NrrQ�,// /I-656•07 tsipfntla Dge.,0�� 8Y I • L-IA4 N 0 � JOSEPH R. EVANS, P.E FLORIDA NO. 4392 we W= JWX R M89 DATE: 07110107 SCALE. NTS ays. er JWJ CHx. eY: S. Saffell ow,wiHo No.: 5-2004 SHEET _L OF 8 1.67" 4.5625" —1.67" ci u') Cal co GDOOR PANEL DOOR PANEL & WOOD FRAM WOOD SIDE STILE AND SIDELITE 15 SIDELITE BOTTOM 2. 4 TOP RAIL RAIL WOOD > cli 28 bi a, En LJO W 01-- 0-1 Ld ro U) w —2.375 ou, 0 9 !wl 0 jL z 0gZ3 R Lo r- 0 0 (D 0 to 0 6I 00 rn 0 1-w I(L 4 . 555 —.912"@ .525.1 L q OUTSWING BUMPER THRESHOLD COMPRESSION WEATHERSRTIP IMPERIAL ASTRAGAL 11 IMPERIAL ASTRAGALSCHLEGEL Q-LON QDS 650 STRIKE PLATE .050" EXTRUDED ALUM. EXTRUDED ALUMINUM .075" WALL STEEL PLATE 11.875" D 0 R R 0 8 L-Y• DATE 07110107 PRODUCT RENEWED SCALE:NTS �-.097" . ..Plyl.g.ilh th. Plod" O BuldMgC.& 71a- DWr. BY' Jwj WOOD LOCK BLOCK, 1,71" THK. 9 7 C 4 x 4 STEEL DOOR HINGE A .. pf... rq 4f-- �q .097" THK. STEEL 13Y HAGER E.pl.tf- D. CHK. BY' S. SOffell JOEVANS, L DRAWING NO.: nMhml z FLORSEPH P DA NO. 4392 PS-2004 au stow mw wm Awt IL sHm 8 of 8 JUN. 9.2008 1:40PM BRADCO SUPPLY NO. 9873 P. 1 1 A M FD WAN -DADS COUNTY. FL.0 MA . - - -- ,----- _ -- --- ----- N�TitO•DADbF7.AQLffit-BI7II.DIldCi---- -- BUM PING CODE COMML4SCT OFFICE (ECCO) 140 WEST FLAGLER STIZWET, SUNS 1603 PRODUCT CONTWLDIVISION tffAW FLOWDA 331WI563 (305) 375 Mi FAX (305) 375.2M XTOTICE OF ACCEPTANCE 1\TOA GAF Materials Corp. 13si Aa�s Ra. Wayne, NJ 07470 SCoM. 'this NOA is issued under the a 'cable rnles media-- - ons vmiug the use of constructi0 materials. . The documentatanon submitted bas been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). 'Phis NOA shall not be valid after the expiration date stated below. The BCCO (In Miami add County) and/or the AW (in yes other d=-1vliami Dade-County)-mservelhe-rigbt'to-have-this-product or-matetW-testied for quality assurance purposes, If 4his product ormaterid fails to pednrtur in the accepted manner, the manufacturer will incur the expense of such testing .and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves On right to revoke this acceptance, if it is determined by BCCO that this product ter material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including, the High Velocity Hurricane Zone. DESCRIPTION: Timberline 30 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code: negatively affecting the performance Of this product TE .MWATION.of this NOA Will occur after the W#ation date ar if there has been a revision of change in the manuals, use, and/or manufacture of the product or process- Misuse of this NOA as an endorsement of any product, for_ sales; advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be causefier termination and temovd of NOA. ADVERT: The NOA number premded by the words Miami Dade County, Florida, and followed by the eat =don dale may be displayed in advertiemg lituatuM If any portion of the NOA -h displayed, then it shall betone in its entirety. INSPEMON: A copy of this enure NOA shall be provided.to the user by the manufacturer or its distributors and shall be available for inspection at the job site -at the request of the Building Official. This NOA renms and revises NOA #{05.1115.09 and consists of pages 1 though 4. The submitted documentation was reviewed by AIM 'I1FM �T co,1 �`r NOA No.:064211.02 Expiration Date: 0? 2=2 Appmval Date: 0=167 Page 1 of 4 JUN. 9. 2008 1; OPM BRADCO SUPPLY NO.9873 P. 2 ROomr. SYsTEM APPROvAL too • Roofing Sub-Cateeory: 07310 Asphalt Shingles Materials Dimensional Deck type• Wood 1. -:SCOPE This revises GAF Timberline 30 as manufactured by GAP' Materials Corp described in Section 2 of this Notice of Acceptance. 2.-4--RODUCTDESC1iIMON -- "- - ------ -- - -- - Pro_, d� to ions Test Product Description Timberline 30 13i/4"a 301" TAS 110 FibegUss reinforced heavy weight asphalt roof shingle,'with a laminate profile, 3. EVIDENCE SUBMITTED: Tess Aeencv Test Identifiier Tesj Name/Report Date Underwriters Laboratories, Inc. TAS 107 OINK45803 04/13/94 Center for Applied Engineering TAS 100 257959 04/01/97 Center for Applied Engineering AMU D3462 257989 05113/97 Al Asphalt Technologies, Inc. ASIM D3462 OAF-101 fl2-W 11/02105 PRI Asphalt Technologies, Inc. TAS 100 GAF 044-02-01 01/13/04 FR1 Asphalt Technologies, Inc, TAS 100 GAF-101.02.01 11/09/05 FRI Asphalt Technologies, Inc. TAS 100 GAF-116-02-02 03/23/06 Underwriters Laboratories, Inc. TAS 107 04NK04273. 02=04 Underwriters Laboratories, Inc. Modified ASTM D3161 OSCA42MO 11/1l/05 Underwriters Laboratories, Inc. .TAS 107 06NK05159 08/09/06 Undewriters Laboratories, vac. ASTM D3462 06NK05159 OWN 4. LD WALTIONS 4.1 Fier classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product 4.2 Shall not be installed on roof mean heigbm in excess of 33 fL 4.3 . All products listed herein shall have a quality assurance audit in accordance with the Hodda Building Code and Rule 9B-72 of the Florida Administrative Codo, 5. INSTALLATION 5.1 Shingles d all be installed is compliant with hoofing Application Standard RAS 115. 5.2 Flashing shall be in mordance with Roofing Application Standard RAS 115 5.3 The nmufacturer shall provide clearly written application inst:vctions. SA Exposure and course lgout shall be in compliance with DeW'A', attached. 5S Nailing shall be in compliance with Detail B', attached. NUA, No.A6-1211,02 ExpirsttionDatm 02021/12 ' - Approvalbatm 02fW07 Paget of 4 • JUN. 9. 2008 1: 40PM BRADCO SUPPLY N0.9873 P. 3 • 6. LABELING 6.1 5hiagles shall be labeled with the Miami-Aatle Logo or the wording "Miami -Dade County Product Control Approved". 7. BUILDING PERMIT REQUIREMENTS 7.1 Applict-lier, ioc buildsug parmir b1W be accompanied by copies of die following: - 7.1.1 This Notice of Acceptance. 7.1.2 Any other documents req*cd by the Building Official of the applicable code in order to properly evaluate the installation of this system. 8. MANOFACTUIiING PLANE'S 8.1- -Tampa,-FL- - 8,2 Micbigan aty, IN 8.3 Mobile, AL I DETAIL A NOA No.:06-1211.02 Ex*afion Date: Q=W2 ApprovalDate:6 ► 107 Pa$e3 of 4 JUN. 9.2008 1;40PM BRADCO SUPPLY o NO.9873 P. 4 ;r -. DETAm B Release Tape • `� fasteners' 72" - ; -1" Front Side Side (MaxtmUm Slope 1212) a�-ara i" 1• 6 fasteners -- 7Z`--� — 7" — Front Side (Maximum Slope 21:12) f ant " 2" 2 Back Side END OF THIS ACCVTANCE Release Tape le" NOA No.�6.1211.02 ftpkation Date: MMIA2 Approval Dater 0 AV07 Page 4 of 4 - -- J M®�� — -- --- - - - - � MIAE COUNTY, IDA METRO-DADEFLAGLR BUILDING BUILDING CODE COMPLIANCE OFFICE.(BCCO) . 140 WEST-FLAGLER STREET; SUI E-1G03 - PRODUCT CONTROL DIVISION MIAMI. FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov Southeastern Metals Manufacturing Co., Inc. 11801-Industry Drive Jacksonville, FL 32218 SCOPE: i - - This NOA is tieing issued under the applicable roles and regulations governing the -use of construction materials. The documentation submitted has been -reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control ___Division_(in-.Miami Dade--County)-and/or-,the-AHU-(in-areas-other-than--Miami Dade -County) reserve -the -right to have.this product or material tested for -quality assurance purposes-. if this product -or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing, and the AHJ -may immediately revoke, modify, or suspend the use of such.product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if, it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane. Zone of the Florida Building Code. DESCRIPTION: 0.063" (min,) Aluminum Storm Panels Shutter APPROVAL DOCUMENT: Drawing No. 01-215T, titled" 0.063" Aluminum Storm Panels ", sheets 1 through 3 of 3, prepared by Engco. Inc., dated June 19, 2001, Mast revision #D dated March 28, 2007, signed and sealed by Barry J. Gaines, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by -the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after.a renewal application has been filed and there has been no change in. the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture ofthe' product ror process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises & renews NOA # 01-0718.15 and consists of this page 1, evidence submitted page E-1 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Makar, P.E., M.S. NOA No 06-1012.05 Expiration on Date: 11/15/ 2011 6¢/J,g/7-007 Approval Date: 04/19/2007 Page 1 Southeastern Metals Manufacturing Co.. Inc. - - NOTICE OF -ACCEPTANCE; EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 01-0718.15 A. . DRAWINGS 1. Drawing No. 01-215, prepared by Engco, Inc., last revision #1 dated August 24, 2001, sheets 1 through 3 of 3, signed and sealed by Pedro De Figueiredo, P.E. B. TESTS _ -__l. Test report on Large Missile Impact_Test, .Cyclic Wind Pressure Test, and Uniform Static Air Pressure Test of.063"aluminum storm panels, prepared by Construction Testing Corporation, Report No. 01-016, dated July 04, 2001, signed and sealed by Christopher G. Tyson, P.E. C. CALCULATIONS 1. _Anchor.analysis dated 0711112001 Pages I through 1.3, prepared by Engco, Ax., signed and sealed by Pedro De Figueiredo, P. E. D. MATERIAL CERTIFICATIONS 1. , Mill certified inspection report issued by Vulcan Aluminum dated 0511612001, with chemical composition and mechanical properlies for aluminum alloy 5052-H32. 2. Certified Tensile Test Report Number CTL-0887G, prepared by Certified Testing Laboratories, dated 0711012001 for aluminum, tested per ASTME8-93, signed and sealed by Ramesh Patel, P.E. 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 01-215T, titled" 0.063 "Aluminum Storm Panels ",sheets 1 through 3 of 3, prepared by Engco. Inc., dated June 19, 2001, last revision #D dated March 28, 2007, signed and sealed by Barry J. Gaines, P. E. B. TESTS 1. None. C. CALCULATIONS 1. Revised anchor calculations, dated February 15, 2007, 22 pages, prepared by Barry 1. J. Gaines, RE, signed 'and sealed by Barry J. Gaines, P.E. on February 15, 2007. D. QUALITY ASSURANCE 1. By Miami -Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. None. my A. Makar, P.E., M.S. Product Control Examiner NOA No 06-1012.05 Expiration Date: 11/15/ 2011 Approval Date: 04/19/2007 E-1 1 - 1- TYPICAL .063 ALUMINUM PANEL 6052-H32 f 114Y (Ft- 31 Ka1 d I "= Ks6 3004-H34 ALLOY (F,u- 32 KSI 8 F17r25 X.J. DESIGN PRESSURES: Pd= +80 —80 ,-PSF 5I8' HOLES 1• FROMENDS 7116' HOLE AT MID SPAN 16• HOLES ROUND COINED G 1' FROM ENDS SAFETY EDGE a (, w J , w m - a 116' HOLE AT MID SPAN � 7 m W 51B' HOLES 1/4X1/Y SS- CLINCH STUD • FROM ENDS SPACED AT 13.00 STUD ANGLE LAY -OUT BASIC MODULE �J 1 '' 1 TYPICAL TYPICAL 13.00 TYPICAL 13• OC 13' OC - 2- STUD.ANGLE 6-1n0 I TYP. 6-Irr I TYI-. I TYP. I H= LEGEND 6063-T6 ,ALLOY (Ftua 30 Kat h Fty-25 Kai) • 7/16'0 THRU HOLE - CLINCH STUD . TYPICAL ELEVATION . PANELS CAN BE INSTALLED VERTICALLY OR i HORIZONTALLY USING APPLICABLE ANCHORING i DETAILS A B �e ASH D VING-t ET � � u�i D \ /cc Q TYPICAL DETAIL Reinforced panels With stitch boB and sprhg gut at mld-span secure at each lap jollt with washared wing nut sir I i 86' MAXIMUM PANEL SIZE aR• CG• r:C• AA• CTAMf1A Dr1 CITCC 1-THIS STRUCTURE IS DESIGNED AS PERTHE FLORIDA BUILDING CODE 2W4 EDITION FOR A41AM-DARE COUNTY, ALSO FOR WIND LOADS AS PER ASCE 7-02 USING CORRESPONDING LOADS. 2-DESIGN CRITERIA FOR ALUMINUM, MINIMUM MECHANICAL PROPERTIES AND SAFETY FACTORS ARE IN ACCORDANCE WITH THE -ALUMINUM CONSTRUCTION MANUAL' 2005 EDITION. 3-ALL EXTstunou3 SHALL BE ALLOYS AS SHOWN ON DETAILS. 4- ANCHORS SHALL BE AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING. 6- PRODUCT MARKINGS SHALL BE ONE PER EACH PANEL END AND SHALL BE LABELED AS FOLLOWS: - SOUTHEASTERN METALS MANUFACTURING JACKSONVILLE - FLORIDA MIAMMADE COUNTY PRODUCT APPROVED AS PIZIDI3U(rx RFIKe"5S•.MD BuidhQg C&- . - izxpir^t€flr. I' :lam. e0 2..05r 1 i Il�ialni Daste �� •,��sf(TI Division Monulceturar. Southeastern Metals Manufacturing Co., Inc. 11801 Industry Drlve Jock."Wils - Florldo Tel.: (904) 757-4200 Y Product: 0.063 Aluminum Storm Panels ngIneer of Record: EngC0Inc. CA8116 U71 W. Su .Bv.1. PIUJaOon, R 3V,] ATE CODE FBC TO 2004 W CALCULATIONS .7-02 MIAMI-DADE 02-08-2007 SPACWG A-M2, REMOV EDGE .0311612007 ADD EDG DIST, HDR, SILL 2 ONLY 03=2W7 3 Egineer Seal BARRY J. GAINES FL. PE 18a30 SEMCO JACKSONVILLE. FL PH (904)(396.051 FX "169"207 Drawing Number 01-215T . Sheet 1 of 3 I RETAIL A - WALL MOUNT j 2 OPTIONA2 -REMOVABLE WALL STUDDED ANGLE I ! HEADER (DIRECT MOUNT) OPTION Al -STUDDED ANGLE TO WOOD WALL STRUCTURE: I ' WOOD LAG SCREWS WOOD ANCHOR TYPE; ANCHOR EMBEDMENT: 2 STRUCTURE: HOLLOW BLOCK ORCONCRETE ANCHOR TYPE: }20 All Points solid set W/ 114-20 SS SIDEWALK BOLT ANCHOR EMBEDMENT: 718' MIN. ! 1613r MIN. THIRD LGTH 1 OPTION I 1 OPTION A3 -REMOVABLE WALL STUDDED ANGLE STRUCTURE: WOOD A4 - PANEL MATE PLUS - STRUCTURE: WOOD, CONCRETE AND HOLLOW BLOCK ANCHOR TYPE: kX21' PANEL MATE PLUS EXISTING i STRUCTURE ANCHOR TYPE: }2D BRASS WOOD BUSHING W/ 114.20 SS SIDEWALK BOLT 474 W/ WASHERED WING NUT ANCHOR EMBEDMENT: 1a' (Wood), * (Block), 2' (Cowc1e) r, WALL r----�\ DRESSING ANCHOR EMBEDMENT: 1-1/8" MIN. OPTION AS - FIXED STUDDED ANGLE WALL STRUCTURE- - FLOOR 2 DRESSING Q -i: s 1 1 .EDGEr i DMANCE EXISTING LJ Y V STRUCTURE • 1 j SILL W/ STUD ANGLE I 1 ! C ,EMBEDMEN I , EDGE DIST FOR DIRECT MOUNT AT HEADER OR)SILL PSF -WIND LOAD PRESSURE -± SO PSF FAST. OPTION DESCRIPTION ee• Be' 56" 44" EDGE DIST A-1 VTIW Lao SS Wood Screws w/ 1-1/P" embedment into wood SG-.65 B Eleo 13" 13' 13• 13' 3/4' 4-2 ! ?t14" SOIidSet-7/6• embedment into C90 -Hollow Block b All Points 13' 13' 13' 13' 2- H/4" Solid -Set 7/8' embedment Into 3000 psi Concrete By All Points 13• 13" 13' 13' 2"' A-3M2 i ;114'-2DX518• Brass Wood Bushin h All Points w/1/4'S 20 s/W Embed 1-1/8' 6.5" 12' 13 ' 13" 3/4" A-4 1 11/4• Male Paneimate Plus- 2' embedment Into 3350 i Concrete,D Elco 13' 13• 13• 13` 2-1/2" A-4 1 I1/4' Male Panelmate Pius- 1-1/4 embedment Into C90 - Hollow Black by Elco '6.5' 13• 13' 1 13• 1 3" A-4 I 11/4' Male PanelmatePlus -1-71W embedment Into wood SG=.84 , By Eloo 13' 13' 13' 13" 3.4' A-5 f H11C Male Panelmate 7-3/4 embedment Into 3000 psi Concrete, by Elco 13" 13" 13' 1 13" 1 1-1/2' A-5 ! 11/4" Mate Panelmate' 1-1/4 embed into C9D- Hollow Block 1780psi, b Elco 6.w 13" 13• 1 13' 3' A-5 I 11/4• Male Panelmale'-14/B" embedment Into wood SG=.63 B Elco 13• 13• 13• 13" 3/4• A-6 1 It/4' Crete -Flex w/ 1-1/4' embedment Into C90 - Hollow Stock b Elco !i 13- 13" 13' 13" 2-1/2' ASIB3 1 4' Ta n w/ 1-W4" embedment into 3000psi COnc b Elco 13" 13" 13' 13" 2-1/2" tnufaefurer: `y) outheastern Co., - Inc. 11591 Indwfry Draw Tksonvllle - Flertda Tel.: (904) 757-4200 Product: 0.063 Aluminum Storm Panels Engineering of Record: ErlgCo Ine CA 8116 69r1 W. 6wuiae 6N 11N Pla ."%FL=13 Td.:(65415654IM1 Da MIMI \SCE 7-02 MIAMI-DADE o2-08-2007 I'B' SPAC'NG A-3182, REMOV EDGE DIST 03/162007 "C' ADO EDO DIST, HDR, SILL SHT 2 ONLY 03=21D07 /'D' TO PROVIDE THREE BHT (1, 2.3) CONSISTANCY 8P..812007 Engineer Seal BARRY J. GAINES FL PE 18830 SEMCO JACKSONVILLE, FL PH (904)696.4661 FX (SD4) 686-4207 Drawing Number 01 —215T Sheet 2 of 3 z 0 z EXISTING /STRUCTURE DETAIL D DESIGN PRESSURE - ANCHORAGE ENT,EDGE DIST. OR SIL S D ANG E WALL DRESSING Manufacturer. INSTALLATION ON Southeastern WOOD STUDDED WALL Metals Manuf acturing THIS DETAIL CAN BE INSTALLED Co., Inc.' AT TOP OR BOTTOM OF PANELS 11801 Industry Drive LIMITED BY Pd<=80 PSF AND 86" MAXIMUM Jacksonville Mrida TYPICAL MINIMUM PANEL SIZE. Tel.. (904) 757-4200 GLASS SEPARATION 2 318" (2) 114- LAG SCREWS WI 15132- MIN. THRII EMBEDMENT INTO SG:.55 WOOD STUD SPACED AT 24' MAX OC. Product. Q1? At ' STUDDED ANGLE TO 2X WOOD 0.063 DPn STRUCTURE: WOOD Aluminum ANCHOR TYPE:;' WOOD LAG SCREWS ANCHOR EMBEDMENT: 1 112* MIN, Storm Panels 7. ANCHOR SPACING: 1T OC Engineering of Reco EngCo Inc cAel 6 697, W. STUDDED ANGLE TO Itr ALUMINUM pu..fi� R. =13 ttN r ALUMINUM WALL &W-I /2 ANCHOR TYPE: j--14.1t HWH#3 DPJLL-FLEX SELF DRILLING D—D&I601 SCREWS By ELOD Sm :Mrs ANC R y. ANCHOR SPACING: 170C. Deign br. PPMF E EDME PRODUCT MVIS-1-71) evlsiDn:' UPDATE CODE FB TO 2004 C0MpVDg Wfth &NE CALCULATIONS FOR STUD FRAMING AT 16- or,-. ng CW&! ASCE7-02MLAMI-OADE 02-08-2DO7 IX4XIIS'ORZX4XI/r Ruidi 2 ,.05- -T SPAC-NG A-31B . REMOV EDGE DIST OWIfir2q07 A BD63-TB ALUM. TUBE OR Ac . — DRESSING 2)(4 PT WOOD IiGi: 12 'C ADD EDG DIST. HDR, SILL FOR STUD FRAMING AT 24' OC: SHY 2 ONLY 03/WrJ007 2X6 PT WOOD Ev -D'TO PROVIDE THREE )USTING PT WOOD B SHY (1. 2.3) CONSISTANCY STUD FRAMING 'Co2iml 3=2007 SPACED AT 16' OR 24"OC Miami Dade et E INEER OF REV. &B,C,D ONLY �Z -15 1 p EnlneerS" BARRY J. GAINES FL. PE 18B33 SEMCO JACKSONVILLE. FL PH (904)6964651 FX ON) 696- 1 Drowl ng Number 01 —21 5T Sheet 3 of 3 THIS ENGINEERING SUPERSEDES ALL OTHERS ATTN: to-a-F-91Z SIZE" Main Office: 900 Cox Road. Cocoa Florida, 32926 Phone: 321-633-7511 Fax: 321-633-7544 Rockledge Plant Delray Beach Plant Palm City 201 Paint St. 9500 W Atlantic Ave 3581 SW Corporate Pkwy. Rockledge, Florida Delray Beach, Florida Palm City, Florida 32955 33446 34990 PERMITTING SHIPPING FRAMER INSPECTION FILE ngineering Job #: WIL-5438 Date: 08108/08 August 8, 2008 Paul Davis Restoration & Remodeling 1950 SW Biltmore Street Port St. Lucie, FL 34984 Phone 772-340-2080 Fax 772-340-2464 Subject Truss Engineering Specifications Job # WIL 5438 Model Thiery Addition Lot/Block/Section Address 5900 Sunset Blvd Ft. Pierce, FL 34982 St Lucie County 11�R!O m'G. 900 Cox Road, Cocoa, FL 32926 321-633-7511 — 321-633-7544 Fax Occupancy Group: Additions Occupancy Category: II Exposure Catezory: C Wind Speed. 140 Enclosure Classification: Partial Index of attached: 1. Truss Placement Diagram with Truss to Truss Connector Schedule (if applicable) 2. Reaction Summary (index of attached drawings & loads on structure.) 3. Engineering Summary Sheet for each truss 4. Standard Details (if applicable) This cover sheet will serve as a blanket certification for all the attached items under Rule 61G15-31.003 of the Florida Department of Professional Regulation using design criteria from FBC 2004 Edition. I certify that all Space Coast Truss, Inc.'s truss specifications are designed for wind pressures using wind load calculations from ASCE 7 which has been adopted by FBC 2004 Edition. The items are enclosed in a sealed binder which inhibits tampering. If this truss placement diagram is mirrored for alternate garage right/left swing, these truss specifications will remain unchanged. Mitek is the computer program used for engineering these trusses. Should you have any questions concerning this engineering, please do not hesitate to contact us at 321-633-7511. Please have the job number available and request to speak to the truss designer whose name is indicated at the bottom of your truss placement diagram so that we may better serve you. Truss Design Engineer Manuel Martinez, PE Florida License #47182 08 2008 Structural Engineer ofRecord. Name. License #: Address: 1A 0.006(3) Approved As Corrected Review -No Memo -kW. FY1ow and approval is a sign concept'aft .lVolWand compua.." 1',tract DocunmWA --I nnrrnlatwl At tdWor is respu,.bw,. Ilk job site; for informs. at techniques o, cuo -, StoWw and approval do..- . .:,,,cation processes :lIe work of all trade& Irom compliance with the c :act drawi s andUeci ications. pace Coast Truss, Inc (7.02) To: Reaction Summa DO Cox Road Job Number: 'ocoa, FI 32926 No Name Found. hone:(321) 633-7511 Fax: (321) 633-7544 Page: I Date: Project ID: 08-08-2008 - 10:36:55 AM 5438 -0ject: Block No: [odel' Lot No: Account No: ontact: Site: Office: Deliver To: Designer: SCT ame: Salesperson: hone: Quote Number: ax: entative Delivery Date: Profile: Qty: Truss Id: Span: Truss Type: Slope: Reactions: 4-3-2 Joint 2 Joint 10 9 TI 27 - 8 - 0 ROOF TRUSS 3.00 1210 lbs. 1190 lbs. 2X4/2X6 0.00 -1499lbs. -1499lbs. 4-3-2 Joint 2 Joint 14 Joint 13 Joint 12 Joint 10 1 T1GE 27 - 8 - 0 GABLE 3.00 360 lbs. 229lbs. 137 lbs. 621 lbs. 360 lbs. �I II II II II II II 0.00 -573Is. -302lbs. '-138lbs. -816lbs.-589lbs. 2-2-0 Joint I. Joint 4 Joint 3 1 VT16 17 - 4 - 0 VALLEY 3.00 229lbs. 682 lbs. 229 lbs. _ 0.00 -294lbs. -761lbs.-301lbs. 3-0-0 Joint 1 Joint 8 Joint 7 Joint 6 Joint 5 1 VT24 24 - 0 - 0 VALLEY 3.00 204 lbs. 534 lbs. 122 lbs. 534 lbs. 204 lbs. II II_� 0.00 -258lbs. -754lbs. -57Is. -754lbs.-2661bs. 0-6-0 Joint 1 Joint 2 Joint 3 1 VT4 4-0-0 VALLEY 3.00 0.00 37 lbs. 791bs. 75 lbs. 37 lbs. -127lbs. -82lbs. 1-4-0 Joint 1 Joint 3 1 FVT8 10-8-0 VALLEY 3.00 3071bs. 307 lbs. y� �� 0:00 3741bs. -374lbs. ob Truss Truss Type Qty Ply 0 0 1438 T1 ROOF TRUSS 9 1 Job Reference (optional) SC Truss, 900 Cox Road, Cocoa, FL 32926, M. Martinez PE#47182 6.500 s Mar 8 2007 MiTek Industries, Inc. Fri Aug 08 10:35:40 2008 Page 1 -2-0-0 4-2-3 6-9-4 13-10-0 15-9-0 20-7-13 27-8-0 29-8-0 • 2-0-0 4-2-3 2-7-1 7-0-12 1-11-0 4-1 0-13 7-0-3 2-0-0 Scale =1:51. 3x6 MT20= 3.00 12 3x6 MT20= 6 48 MT20= 7 5 3x4 aT20= 5x10 MT20H� 1.5x4 MT201 I 5x8 MT20 � 9 4 0 W 3 N W 7 8-2-0 10 2 v 11I o' 4x8 MT20= 15 14 16 17 13 12 4x8 MT20= 2x4 MT20 II 7x8 MT20= 7x6 W20= 3x4 MT20= 6-11-0 8-10-0 11-11-0 4-2-3 6-9-4 15-9-0 20-7-13 27-8-0 4-2-3 2-7-1 8-11-12 4-10-13 7-0-3 Plate Offsets X,Y : 3:0-4-0,0-3-0 , 6:0-3-0,Ed e , 7:0-3-8,0-2-0 , 9:0-5-0,0-3-0 , 1 3:0-3-0,0-5-4 , 14:0-4-0,0-4-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 1.00 Vert(LL) -0.34 13-14 >949 240 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.62 Vert(TL) -0.99 13-14 >327 180 MT20H 187/143 BCLL 0.0 Rep Stress Incr NO WB 0.62 Horz(TL) -0.09 10 n/a n/a BCDL • 10.0 Code FBC2004/TP12002 (Matrix) Wind(LL) _ 1.10 13-14 >294 180 Weight: 140 lb LUMBER BRACING TOP CHORD 2 X 4 SYP SS *Except* TOP CHORD Structural wood sheathing directly applied or 3-3-15 oc purlins. T3 2 X 4 SYP No.1, T1 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 3-4-0 oc bracing. BOT CHORD 2 X 6 SYP SS WEBS 2 X 4 SYP No.3 *Except* W 1 2 X 4 SYP No.2 REACTIONS (lb/size) 2=1210/0-7-10, 10=1190/0-7-10 Max Horz2=155(LC 4) Max Uplift2=-1499(LC 6), 10=-1499(LC 7) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/29, 2-3=-3432/4237, 3-4=-2716/3362, 4-5=-2658/3441, 5-6=-211/175, 6-7=-191/196, 7-8=-2694/3510, 8-9=-3164/4224, 9-10=-3198/4078, 10-11=0/29 BOT CHORD 2-15=-3939/3298, 14A6=-3942/3300, 14-16=-2983/2582, 16-17=-2983/2582, 13-17=-2983/2582, 12-13=-3407/2877, 10-12=-3743/3054 WEBS 4-14=-11/295, 7-13=-663/790, 3-15=-244/257, 9-12=-243/629, 3-14=-863/1069, 5-7=-2604/3558, 8-12=-515/420, 8-13=-565/641 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 140mph (3-second gust); h=15ft; TCDL=4.2psf; BCDL=5.8psf; Category II; Exp C; partially; MWFRS gable end zone and C-C Exterior(2) zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.00. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are M1120 plates unless otherwise indicated. 5) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1499 lb uplift at joint 2 and 1499 lb uplift at joint 10. 7) Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 75 lb down at 10-0-0, and 75 lb down at 14-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) FZegular: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pif) Vert: 2-10=-20, 1-6=-54, 6-11=-54 Concentrated Loads (lb) • Vert: 16=-7517=-75 Job Truss Truss Type Qty Ply 00 5438 T1GE GABLE 1 1 Job Reference (optional) SC Truss, 900 Cox Road, Cocoa, FL 32926, M. Martinez PE#47182 6.500 s Mar 8 2007 MFek Industries, Inc. Fri Aug 08 10:35:41 2008 Page 1 -2-0-0 , 13-10-0 27-8-0 29-8-0 , 2-0-0 13-10-0 13-10-0 2-0-0 Scale = 1:51. 3.00 F12 4x4 MT20= 5x10 MT20% 1.5x4 MT20 II 6 1.5x4 MT20 II 5x10 MT20zz: 1.5x4 MT20 I 1 5 7 1.5x4 MT20 11 4 8 3 9 1 v 2 10 11 3x6 MT20= 19 18 17 16 15 14 13 12 3x6 MT20= 1.5x4 MT20 11 1.5x4 MT20 11 5x5 MT20= 1.5x4 MT20 11 1.5x4 MT20 11 1.5x4 MT20 11 1.5x4 MT20 11 27-8-0 27-8-0 Plate Offsets X,Y : 2:0-2-12 0-1-8 , 3:0-5-0 0-3-4 9:0-5-0,0-3-4 , 10:0-2-12,0-1-8 , 12:0-2-8 0-0-12 , 15:0-2-8,0-0-4 19:0-2-8,0-0-12 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.90 Vert(LL) 0.04 11 n/r 120 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.45 Vert(TL) 0.13 , 11 n/r 90 BCLL 0.0 Rep Stress Incr NO WB 0.27' Horz(TL) 0.01 10 n/a n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Wind(LL) -0.07 11 n/r 90 Weight: 114lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.1 "Except' TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlin's. T1 2 X 4 SYP No.2, T1 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. BOT CHORD 2 X 4 SYP No.2 OTHERS 2 X 4 SYP No.3 REACTIONS (lb/size) 2=359/27-8-0, 16=120/27-8-0, 17=227/27-8-0, 18=-137/27-8-0, 10=359/27-8-0, 19=622/27-8-0, 14=227/27-8-0, 13=-137/27-8-0, 12=622/27-8-0 Max Horz2=150(LC 4) Max Uplift2=-573(LC 6), 16=-40(LC 4), 17=-303(LC 4), 18=-137(LC 10), 10=-589(LC 7), 19=-815(LC 4), 14=-302(LC 5), 13=-137(LC 11), 12=-815(LC 5) Max Grav2=361(LC 10), 16=120(LC 1), 17=230(LC 10), 18=138(LC 4), 10=361(LC 11), 19=622(LC 10), 14=230(LC 11), 13=137(LC 5), 12=622(LC 11) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/25, 2-3=72/129, 3-4=-37/236, 4-5=0/216, 5-6=-4/303, 6-7=-4/303, 7-8=0/216, 8-9=-37/236, 9-10=-72/88, 10-11=0/25 BOT CHORD 2-19=-1/135,.18-19=-18/197, 17-18=-18/197, 16-17=-18/197, 15-16=-18/197, 14-1 5=-1 8/197, 13-14=-18/197, 12-13=-18/197, 10-12=-1/120 WEBS 6-16=-96/65, 5-17=-159/342, 4-18=-97/68, 3-19=-416/892, 7-14=-159/342, 8-13=-97/68, 9-12=-416/892 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 140mph (3-second gust); h=15ft; TCDL=4.2psf; BCDL=5.8psf; Category 11; Exp C; partially; MWFRS gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.00. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 573 lb uplift atjoint 2, 40 lb uplift at joint 16, 303 lb uplift at joint 17, 137 lb uplift atjoint 18, 589 lb uplift atjoint 10, 815 lb uplift at joint 19, 302 lb uplift atjoint 14, 137 lb uplift at joint 13 and 815 lb uplift atjoint 12. LOAD CASE(S) Standard lob Truss Truss Type City Ply 0 0 5438 VT16 VALLEY 1 1 Job Reference (optional) SC Truss, 900 Cox Road, Cocoa, FL 32926, M. Martinez PE#47182 6.500 s Mar 8 2007 MiTek Industries, Inc. Fri Aug 08 10:35:41 2008 Page 1 8-8-0 17-4-0 8-8-0 8-8-0 Scale = 1:27.6 6x14 MT20H= 3.00 12 2 T1 T T1 3 1 3x6 MT20= 5x5 MT203x6 MT20= = 17-4-0 17-4-0 Plate Offsets X,Y : 1:0-6-3,0-1-8 , 3:0-2-3,0-1-8 , 4:0-2-8 0-3-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES_ GRIP TCLL 20.0 Plates Increase 1.25 TC 0.89 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.49 Vert(TL) n/a - n/a 999 MT20H 187/143 BCLL - 0.0. Rep Stress Incr YES WB 0.28 Horz(TL) 0.00 3 n/a n/a BCDL,- 10.0 Code FBC2004/TP12002 (Matrix) Weight: 51 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0.oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 SYP No.3 REACTIONS (lb/size) 1=213/17-4-0, 3=213/17-4-0, 4=682/17-4-0 Max Horz 1=60(LC 4) Max Upliftl=-294(LC 4), 3=-301(LC 5), 4=-761(LC 6) Max Grav1=230(LC 10), 3=230(LC 11), 4=682(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-61/103, 2-3=-61/93 BOT CHORD 1-4=0/36, 3-4=0/35 WEBS 2-4=-462/943 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 140mph (3-second gust); h=15ft; TCDL=4.2psf; BCDL=5.8psf; Category 11; Exp C; partially; MWFRS. gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.00. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) All plates are M1120 plates unless otherwise indicated. 5) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 6) Gable requires continuous bottom chord bearing. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 294 lb uplift at joint 1, 301 lb uplift at joint 3 and 761 lb uplift at joint 4. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 0 0 5438 VT24 VALLEY 1 1 Job Reference o tional SC Truss, 900 Cox Road, Cocoa, FL 32926, M. Martinez PE#47182 6.500 s Mar 8 2007 MiTek Industries, Inc. Fri Aug 08 10:35:41 2008 Page 1 12-0-0 24-0-0 e 12-0-0 12-0-0 Scale =1:38. 4x4 MT20= 3.00 F12 3 1.5x4 MT20 11 1.5x4 MT2011 2 4 T1 T 2 T1 T T 1 5 3x6 MT20= 3x6 MT20= 1.5x4 MT2011 5x5 MT20= 1.5x4 MT2011 24-0-0 24-0-0 Plate Offsets X,Y : 1:0-6-3,0-1-8 , 5:0-2-3,0-1-8 , 7:0-2-8,0-3-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.81 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.46 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.24 Horz(TL) 0.00 5 n/a . n/a BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 77 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing.. OTHERS 2 X 4 SYP No.3 REACTIONS (lb/size) 1=205/24-0-0, 5=205/24-0-0, 7=123124-0-0, 8=534124-0-0, 6=534/24-0-0 Max Horz 1=87(LC 4) Max Upliftl=-257(LC 6), 5=-266(LC 7), 7=-56(LC 6), 8=-754(LC 6), 6=-754(LC 7) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-46/73, 2-3=-42/228, 3-4=-42/228, 4-5=-43/48 BOT CHORD 1-8=0/93, 7-8=0/93, 6-7=0/93, 5-6=0/93 WEBS 3-7=-109/164, 2-8=-366/811, 4-6=-366/811 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 140mph (3-second gust); h=15ft; TCDL=4.2psf; BCDL=5.8psf; Category II; Exp C; partially; MWFRS gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.00. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 5) Gable requires continuous bottom chord bearing. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 257 lb uplift at joint 1, 266 lb uplift at joint 5, 56 lb uplift at joint 7, 754 lb uplift at joint 8 and 754lb uplift at joint 6. LOAD CASE(S) Standard 5438 I1 2-0-0 3.00 F12 VALLEY 1 1 Job 6.500 s Mar 8 2 3x6 MT20zz 4-0-0 Industries, Inc. Fri Aug 08 10:35:42 2008 Page 1 4-0-0 2-0-0 Scale =1:6: 3 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.07 Vert(LL) n/a - n/a 999 MT20 244/190 TCDL 7.0 Lumber Increase 1.25 BC 0.00 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL,' 10.0 Code FBC2004fTP12002 (Matrix) Weight: 6 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 1=38/4-0-0, 2=76/4-0-0, 3=3814-0-0 Max Horz 1=11(LC 4) Max Uplift1=-79(LC 6), 2=-127(LC 6), 3=-81(LC 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-7/31, 2-3=-7/31 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 140mph (3-second gust); h=15ft; TCDL=4.2psf; BCDL=5.8psf; Category II; Exp C; partially; MWFRS gable end zone and C-C Exterior(2) zone; cantilever left and right exposed; Lumber DOL=1.33 plate grip DOL=1.00. This truss is designed for C-C for members and forces, and for MWFRS for reactions specified. 3) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 4) Gable requires continuous bottom chord bearing. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 1, 127 lb uplift at joint 2 and 81 lb uplift at joint 3. 6) Beveled plate or shim required to provide full bearing surface with truss chord atjoint(s) 2. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 00 5438 VT8 VALLEY 1 1 Job Reference o tional SC Truss, 900 Cox Road, Cocoa, FL 32926, M. Martinez PE#47182 6.500 s Mar 8 2007 MiTek Industries, Inc. Fri Aug 08 10:35:42 2008 Page 1 5-4-0 10-8-0 5-4-0 5-4-0 ' Scale =1:17. 3x6 MT20= 3.00 12 2 T1 T1 1 3 131 3x5 MT20% 3x5 MT20z:: 10-8-0 10-8-0 Plate Offsets X,Y : 2:0-3-0,Ed e LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.44 Vert(LL) n/a - n/a 999 MT20 2.44/190 TCDL 7.0 Lumber Increase 1.25 BC 0.30 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.02 3 n/a We BCDL 10.0 Code FBC2004/TP12002 (Matrix) Weight: 29 lb LUMBER BRACING TOP CHORD 2 X 4 SYP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-9-5 oc bracing. REACTIONS (lb/size) 1=307/10-8-0, 3=307/10-8-0 Max Horz 1=-33(LC 5) Max Upliftl=-373(LC 6), 3=-373(LC 7) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-660/1230, 2-3=-660/1230 BOT CHORD 1-3=-1121/630 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 140mph (3-second gust); h=15ft; TCDL=4.2psf; BCDL=5.8psf; Category II; Exp C; partially; MWFRS gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.00. This truss is designed. for C-C for members and forces, and for MWFRS for reactions specified. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 5) Gable requires continuous bottom chord bearing. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 373 lb uplift at joint 1 and 373 lb uplift at joint 3. LOAD CASE(S) Standard t ATTACH EACH VALLEY MEMBER TO EACH SUPPORTING TRUSS WITH 560# CONNECTION OR WITH (2) USP RT7 CONNECTORS OR EQUIVALENT. +LARGER SPANS MAY BE BUILT AS LONG AS THE VERTICAL HEIGHT DOES NOT EXCEED 12-0-0. NOTE: BOTTOM CHORD MAY BE SQUARE CUT OR PITCHED CUT. CUT FROM 2x6 OR LARGER AS REQ'D ++ 4-0-0 SPAN W4x4 W2x4 W1x3 W2x4 ++ 8-0-0 SPAN W1 SPACE COAST TOTLD FqT 1QRQ ++ 16-0-0 SPAN ++ 20-0-0 SPAN XXX 2z4 PURLINS W2x4 )PTIONAL STUB ND DETAIL (X) 2x6 SP #2 OR BETTER SLEEPER, ATTACH THROUGH SHEATHING TO TRU55L5 BENEATH WITH (3) 16D COMMON OR (4) GUN NAILS. (Y) ATTACH BOTTOM CHORD OF VALLEY GABLE TO SLEEPER WITH 16D COMMON NAILS ® 6" O.C., OR GUN NAILS ® 4" O.C. (Z) VALLEY GABLE TRUSS, REFER TO GABLE END DETAILS. IN LIEU OF 1 x4 "T" BRACING, 1 x4 #3 HEM —FIR (OR BETTER) CONTINUOUS LATERAL BRACING MAY BE USED. Attach WITH (2)-8d OR (2) 0.128"x3" GUN NAILS. BRACING MATERIAL TO BE ATTACHED AT BOTH ENDS TO A SUITABLE SUPPORT. FOR VALLEY VERTICALS THAT ARE OVER 7'9" TALL, APPLY 1x4 "T" BRACE, SAME GRADE AS WEB MEMBER. ATTACH WITH 8d OR 0.128"x3" GUN NAILS 0 6" O.C. MAXIMUM VALLEY HEIGHT MAY NOT EXCEED 12'0" TRUSS TOP CHORD UNDER VALLEY SET MUST HAVE SHEATHING ATTACHED TO THEM WITH NAILS. SPACED PER CODE REQUIREMENTS, OR PROPERLY ATTACHED VALLEY TRUSSES MAY BE USED IN LIEU OF SHEATHING OR PURLINS, SEE NOTE (••) 150 MPH WIND, 30 FT —MEAN HGT, ASCE 7-05, PART. ENC. BLOG, LOCATED ANYWHERE IN ROOF, CAT II, EXP C, WIND TCDL=5.0 PSF, WIND BCDL=5.0 PSF. XXX—FOR'VALLEY TRUSSES RUN PARALLEL WITH TRUSSES BELOW, FASTEN 2x4 #2 SYP PURLINS @ 48" O.C. WITH (2) 16d NAILS EACH END, ATTACH VALLEY TRUSSES TO PURLINS USING STANDARD ** NOTE ABOVE. (20 gauge) 1 "-1/4 wide strap Girder Truss TRUSS TO TRUSS STRAP DETAIL USE (x) 1 od nails per chart (20 gauge) x 1"-1/4 wide strap 10) 10d nails (5 each end of strap) = 805# uplift 12) 10d nails (6 each end of strap) = 970# uplift 14) 10d nails (7 each end of strap) = 1130# uplift 16) 10d nails (8 each end of strap) = 1250# uplift Double up Straps. as required for uplift min. bracing 1 x4 - 1 Oft O.G. spacing w/ (2) 8d nail or per FOR / ARCH rigid cig Straps may be used in conjunction with hanger as required for uplift strap per additionE uplift requirement. hanger rated for reactio but under uplift requirement FLAT GIRDER BOTTOM CHORD BRACING DETAIL FOR PORCH GIRDERS BELOW OR WITHOUT CLG DIAPHRAGM PER TRUSS ENGINEERING (20 gauge) 1 "-1/4 wide strap for uplift USE BRACING @ 4'-0" O.C. MINIMUM • OR PER TRUSS ENGINEERING SHEET USE (4) 10d nails per chord member 2x6 SYP #2 KTS 17 or TS 18 strap attached . to bottom chord of flat girder SPACE COASTTRUSS ANC. 'M =, pp 1410 WHITE FR. TEL: (321)-633-7511 '` TITUSVILLE, FLORIDA 32780 FAX: (321)-633-7511 = '• - �' }1' Ei+� ' p NORTH WEST FLORIDA: SOUTH FLORIDA PLANT NORTH EAST FLORIDA '"�' • ` ' ° �. EST. 1989 3222 N.E. 24TH ST. 9500 W. ATLANTIC AVE. 105 DENVER ROAD %�F•`,,'.F �i..i�t.t;•:• .;;7�� OCALA, FLORIDA 34470 DELRAY, FLORIDA 33446 CRESCENT CITY, FL 32112 'rrrlhriz. ttd�U•,. CORNIER JACK NAILING DETAIL REV=6/20/07 ALR 12 OVER TYPICAL FLAT BEVEL JACK (BJ_) TYPICAL CORNER (CJ_) ASSUMPTIONS: lumber= SYP 2x4 or 2x6 attachment= 3"x 0.131" (10d) GUN NAILS WITH 1.31" OF NAIL INTO CHORD OFF .HIP GIRDER AND /OR SCAB_ . NOTE: NDS = NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION. 132.5# per NIAL (D.O.L. FACTOR = 1.25) NDS TOE NAILS ONLY HAVE 0.83 OF LATERAL RESISTANCE VALUE. CONDITION TYPE and ALLOWABLE REACTION PER JOINT A) UP TO 265 # ROW (1) ONLY REQ. =(2) NAILS TOTAL — NO SCAB REQUIRED. B) UP TO .394 # ROW (1) ONLY REQ: =(3) NAILS TOTAL — NO SCAB REQUIRED. C) UP TO 788 # ROW, (1) & (2) REQ. =(6) NAILS TOTAL — 1 FT SCAB REQ. ON GIRDER CHORD. (connect scab to chord W/(4) 10d gun nails) C) UP TO 1182 # ROW (1) & (2) & (3) REQ. =(9) NAILS TOTAL — 2 FT SCAB REQ. ON GIRDER CHORC (connect scab to chord W/(8) 10d gun nails) ADDITIONAL 1 FT SCAB REQ. ON 2 FT SCAB. (connect 1 FT scab to 2 FT scab W/ (4) -10d gun nails) C�TYPICAL CORNER SET LAYOUT N.T.S. �tffi I2111i1ri81N, 2 OR 3 NAILS (see note above) SCABS END SHOULD BE ANGLED AND/ OR BEVELED OUT FOR TIGHT FIT. SPACE COAST TRUSS, INC. 1410 WHITE DR. TEL: (321)-633-7511 TITUSVILLE, FLORIDA 32780 FAX: (321)-633-7544 NORTH WEST FLORIDA SOUTH FLORIDA PLANT NORTH EAST FLORIDA 3222 N.E. 24TH STREET 9500 W. ATLANTIC AVE. 105 DENVER ROAD OCALA, FLORIDA 34470 DELRAY BEACH, FL 33446 CRESCENT CITY, FL 32112 No.47182 r'= �C E STATE OF OR ;S�ONALE.%��`. REV=6/20/07 ALR TYPICAL GABLE. END DETAIL TYPICAL 1 X4 OR 2X4 "L" BRACE, (IF APPLICABLE), . _ NAILED TO VERTICAL — SEE TABLE FOR MAX. HEIGHTS 12 MATCHES COMMON TRUSSES CONTINUOUS BEARING — SPAN MATCHES COMMON TRUSSES TYPICAL GABLE END : FACIA . , • 1 x4 OR 2x4 EB AS. REQUIRED "L" BRACE DETAIL NOTE: 1) USE 8d GUN NAILS AT 4" O.C. FOR 1 x4 AND 1Od AT 4" O.C. FOR 2x4. 2) MAXIMUM HEIGHT TABLE IS BASED ON USING,. 7/16" STRUCTURAL SHEATHING (MIN.) ON THE FACE OF THE GABLE END TRUSS. 3) MATCH GRADE & SPECIES OF BRACED MEMBER. MAXIMUM HEIGHT TABLE USING —50 PSF DERIVED FROM 140 MPH, C EXPOSURE, ZONE 5, PER ASCE 7-98 SPACING OF MAX. LENGTH MAX. LENGTH MAX. LENGTH VERTICALS NO BRACE 1x4 BRACE 2x4 BRACE* 12" 7'-2" 11'-9" 13'-3" 16" 7'-3" 11'-2" 12'-6" 24" 6'-10" 10'-5" 10'-5" • BEYOND THIS LENGTH USE 2x6. SPACE COAST TRUSS, INC. �Q��,\GENSc��°�'�?-/�' 1410 WHITE DR. TEL: (321)-633-7511 N0.47182 , TITUSVILLE, FLORIDA 32780 FAX: (321)-633-7544_ NORTH WEST FLORIDA SOUTH FLORIDA PLANT NORTH EAST FLORIDA 3 -O STATE OF EST. 1989 3222 N.E. 24TH STREET 9500 W. ATLANTIC AVE. 105 DENVER ROAD OCALA, FLORIDA 34470 DELRAY BEACH, FL 33446 CRESCENT CITY, FL 3211 REV= ALR GENERAL VALLEY NOTES: (1) RAFTERS TO BE 2x4 SPACED 24" O.C. UP TO 8', USE 2x6 UP TO 12' LENGTH. (2) RAFTER LENGTHS (FROM RIDGE TO CLEAT) OVER 12'-0" TO HAVE (2x4) COLLAR TIE, OR KICKER, AT 1 /2 RAFTER SPAN (UP TO 24'-0" MAX RAFTER LENGTH). (3) RIDGE BOARD SHALL BE 2x6 MIN. FOR 2X4 RAFTERS, & 2X8 MIN. FOR 2X6 RAFTERS. (4) ATTACH RAFTERS 4' OR LONGER TO RIDGE BOARD AND CLEAT USING (1) USP RT7 CONNECTOR, NAILED WITH (10) 8d x 1-1/2" NAILS, ALL OTHERS TOE —NAIL WITH 0.131 x 3" GUN NAILS. (5) ALL CONVENTIONAL FRAMING LUMBER SHALL BE SPF STUD GRADE OR BETTER. 0 (1) RT7 ® EA. END OF ZZ,� TRUSSES BELOW LONG FRAMING MEMBER. " (SEE NOTE #4.) (5) 1Od GUN NAILS EACH END. (2)2x4 CLEAT UNDER VALLEY FRAMING ANCH TO EA. TRUSS BELOW W/ (4) 0.131 x 3" GUN NAILS FOR VALLEY RAFTERS 6' AND LESS. OVER 6' US 12" STRAP. IF CLEAT IS OVER SHEATHING & VALLEY RAFTER IS OVER 6' LONG, USE (1) 3/8" x 4" LAG SCREW W/ 1" WASHER PER TRUSS OR CUT SLOT & WRAP 12" STRAP (ANY MFGR) AROUND TRUSS BELOW. FILL ALL HOLES W/ 8d x 1-1/2" NAILS (MIN.), SPACED (2) TRUSSES MAX. r50l VALLEY FRAMING DETAIL z�uos SCALE: NTS SPACE COAST TRUSS, INC. 1 1410 1M1HITE DR. TEL: (321)-633-7511 TITUSVILLE, FLORIDA 32780 FAX: (321)-633-7544 NORTH WEST FLORIDA SOUTH FLORIDA PLANT NORTH EAST FLORIDA 3222 N.E. 24TH STREET 9500 IV. ATLANTIC AVE. 105 DENVER ROAD OCALA, FLORIDA 34470 DELRAY BEACH, FL 33446 CRESCENT CITY, FL 32112 COLLAR TIE (AS REQUIRED, SEE NOTE 2). USP UH26 FASTENED TO PEAK OF PREVIOUS TRUSS. E Sic ��- No.47182 ;-off STATE OF �zi: �''�� SS�O N Al . �E� r�``�• TYPICAL PIGGYBACK ATTACHMENT DETAIL WIND DESIGN: MAX. 140 MPH PER ASCE 7-98. NOTE: 1) 2x4 PURLINS ON FLAT TOP CHORD SECTION OF BASE TRUSS AT ALL JOINTS. NOT TO EXCEED 4'-0" O.C. OR THE MAXIMUM ALLOWABLE PURLIN SPACING' OF BASE TRUSS— (SEE BASE TRUSS ENGINEERING FOR MAX. SPACINGG) ATTACH PURLINS TO TOP CHORD OF BASE TRUSS WITH MIN. 2 EA., 10d NAILS. 2) IF SHEATHING DOES NOT OVERLAP PIGGYBACK / BASE TRUSS INTERFACE BY AT LEAST 8", ATTACH PIGGY BACK USING ONE OF THE FOLLOWING: a— 1—A" X 20" 20 GAUGE STRAP (USP # LSTA-12 OR EQUIVALENT) TO ONE SIDE OF TRUSS CENTERED ON INTERFACE WITH MIN. 5 EA. 8d NAILS EACH SIDE OF INTERFACE; b— 2x4 X 4'-0" GRADED SCAB TO ONE SIDE OF TRUSS CENTERED N ON INTERFACE WITH MIN. 10d NAILS STAGGERED 3" O.C. FULL LENGTH OF SCAB; c— • 6"x8" NOM. • 1 /2" STRUCTURAL SHEATHING GUSSET PLATE TO BOTH SIDES OF TRUSS CENTERED ON INTERFACE WITH MIN. 5 EA. 8d NAILS EACH SIDE OF INTERFACE. 3) FOR PIGGBACKS OVER 12'-0" IN LENGTH USE ONE OF THE FOLLOWING IN ADDITION TO THE ABOVE REQUIRMENTS a— ATTACH MITEK 18 go 7H HAMMER ON PLATES ON EACH SIDE OF TRUSS AT EACH BASE TRUSS JOINT; b— USP FRAMING ANCHOR HCDP OR SIMPSON H 2.5, ONE CONNECTED TO PIGGYBACK AND PURLIN, AND ONE CONNECTED TO PURLIN AND BASE TRUSS STARTING AT MIDDLE OF PIGGYBACK AND EVERY OTHER PURLIN; c— 6"x8"x 1 / 2" STRUCTURAL SHEATHING GUSSET PLATE AT EACH BASE TRUSS JOINT BOTH SIDES OF TRUSS, USING MIN. 3 EACH 6d NAILS EACH CHORD— (TOTAL 12 NAILS) SPACE COAST 1410 WHITE DR. TITUSVILLE, FLORIDA 32780 TRUSS, INC. TEL: (321)-633-7511 FAX: (321)-633-7544 NORTH WEST FLORIDA I SOUTH FLORIDA PLANT I NORTH EAST FLORIDA 3222 N.E. 24TH STREET 9500 W. ATLANTIC AVE. 105 DENVER ROAD OCALA, FLORIDA 34470 DELRAY BEACH, FL 33446 CRESCENT CITY, FL 3211s No.47182 r i 1 STATE OF ,S',ONA1.0%,•��• REV-6/20/07 ALR WEB LATERAL BRACING RECOMMENDATIONS DIAGONAL BRACING (X—BRACING) - (SEE MAX. WEB FORCE CHART) 10d GUN NAILS _ (SEE NOTES 4 -- AND 5) -- TRUSS WEB MEMBERS LATERAL BRACING _ - TYPICAL WEB BRACING GENERAL NOTES: 1) THE DIAGONAL BRACING (X— BRACING) TRANSFER THE CUMULATIVE LATERAL BRACING BRACE FORCES INTO THE ROOF AND/OR CEILING DIAPHRAGM_ NO ADDITIONAL MATERIALS TYPE LATERAL FORCE HAS BEEN ADDED FOR WIND. 2) THESE DIAPHRAGM CALCULATIONS ARE BASED_ ON THE LATERAL BRACE A 1 x4 #2 STD. CONST. CARRYING 2% OF THE WEB FORCE. (SPF, DF, HF, OR SYP) 3) DIAGONAL BRACING MATERIAL MUST BE THE SAME SIZE AND GRADE (OR BETTER) AS THE LATERAL BRACING MATERIAL AND SHALL BE NAILED AT EACH END AND • EACH INTERMEDIATE TRUSS WITH (2) 10d GUN NAILS (131 10d GUN NAILS FOR B 2x3 #3 STD. CONST. (SPF, DF, HF, OR SYP) 2x6 DIAGONALS). 4) CONNECT LATERAL BRACE TO EACH TRUSS WITH (2) 10d GUN NAILS (131 10d GUN NAILS FOR 2x6 LATERAL BRACES). C 2x4 #3 STD. CONST. 5) THE 10d NAILS SPECIFIED SHOULD BE 3.0" LONG AND .131 " IN DIAMETER. (SPF, DF, HF, OR SYP) 6) LATERAL BRACING SHOULD BE CONTINUOUS AND SHOULD OVERLAP AT LEAST ONE TRUSS SPACE FOR CONTINUITY. 7) FOR ADDITIONAL GUIDANCE REGARDING DESIGN AND INSTALLATION OF TRUSS D 2x6 #3 STD. CONST. (SPF, DF, HF, OR SYP) BRACING. REFER TO HIB-91 SUMMARY SHEET. 8) SEE SEPARATE TRUSS ENGINEERING FOR WEB FORCES. MAXIMUM WEB FORCE (LBS.)#* 24" ON CENTER 48" ON CENTER 72" ON CENTER X-BRACE BAY SIZE BRACING. MATERIAL TYPE BRACING MATERIAL TYPE BRACING MAT. TYPE A B C D A B C D C D 10'-0" 4600 * 4600 * 4600 * 6900 * 1344 4600 * 4600 * 6900 * 4034 6382 12'-0" 3942 * '3942 * 3942 * 5914 * 1344 3942 * 3942 * 5914 * 3942 * 5914 * 14'-0" 3450 * 3450 * 3450 * 5175 * 1344 3450 * 3450 * 5175 * 3450 * 5175 * 16'-0" 3066 * 3066 * 3066 * 4600 * 1344 3066 * 3066 * 4600 * 3066 + 4600 * 18'-0" 2760 * 2760 * 2760 * 4140 * 1344 2760 * 2760 * 4140 * 2760 * 4140 20'-0" 2509 * 2509 * 2509 * 3763 * 1344 1 2509 * 2509 * 3763 * 2509 * 3763 + *CONTROLLED BY CONNECTION **MAX. FORCES FROM MITEK DETAIL # LB-001-080193 ENScc--_ SPACE COAST TRUSS, INC. 1410 WHITE DR. TEL: (321)-633-7511 '� N0.47182 ma's �r TITUSVILLE, FLORIDA 32760 FAX: (321)-633-7544 =_ NORTH WEST FLORIDA SOUTH FLORIDA PLANT NORTH EAST FLORIDA %-O STATE OF = �' EST. 1989 3222 N.E. 24TH STREET 9500 W. ATLANTIC AYE. 105- DENVER ROAD ? p� �� 0 R\QP ��t,�. OCALA, FLORIDA 34470 DELRAY BEACH, FL 33446 CRESCENT CITY, FL 3211 %,, �` WEB BRACING RECOMMENDATIONS (PER SPECIFIED CONTINUOUS ROWS .OF LATERAL BRACING IN TRUSS ENGINEERING) r r x x x r r i 10d GUN NAILS x x x T-BRACE r x x x i I -BRACE r i ' 6" O.C. SPACING x r w/ x3'� r x x 6" O.C. SPACING , i w/ .131 x3" x .131 GUN NAILS r GUN NAILS x : x WEB r SEE SPECIFIED NAILING REQUIRMENTS I -BRACE ' x x NOTED ON TRUSS ENIGINEERING r x WEB TYPICAL T—BRACING TYPICAL I —BRACING I -BRACE L- BRACE L- BRAC E WEB WEB WEB I -BRACE L-BRACE SECTION T-BRACE SECTION I -BRACE SECTION NOTE: 1) T-BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL T-BRACING MUST COVER 90% OF WEB LENGTH. 2) I -BRACING TO BE USED WHEN (2) RROWS CONTINUOUS LATERAL BRACING, IS INPRACTICAL I -BRACE - MUST COVER 90% OF WEB LENGTH. (both sides) 3) L-BRACE CONFIGUARATION MAY BE USED IN LIEU OF T-BRACE 4) SEE SPECIFIED NAILING REQUIREMENTS NOTED ON TRUSS ENGINEERING. 5) MATERAL SHALL BE SPF OR SYP GRADED LUMBER. T AND I -BRACING SIZE TABLE (PER SPECIFIED CONTINUOUS ROWSOF LATERAL BRACNG IN TRUSS ENGINEERING) ONE —PLY TRUSS TWO—PLY TRUSS WEB SIZE 1 ROW 2 ROWS 3 ROWS 4 ROWS 2x3 1x4 2x4 2x4 2x4 2x4 1x4 2x4 2x4 2x4 2x6 1x6 2x6 2x6 2x6 2x8 2x8 2x8 2x8 2x8 SPACE COAST TRUSS, INC. ,�'��'��cENsc� 1410 WHITE DR. TEL: (321)-633-7511 No. 47182 TITUSVILLE, FLORIDA 32780 FAX: (321)-633-7544 =*_ NORTH WEST FLORIDA SOUTH FLORIDA PLANT NORTH EAST FLORIDA STATE OF EST. 1989 3222 N.E. 24TH STREET 9500 W. ATLANTIC AVE. 105 DENVER ROAD BEACH, FL 33446 CRESCENT CITY, FL, 3211 's�Q Q' 404 %��`� 0 R\O r OCALA, FLORIDA 34470 DELRAY �'''%ss�O N At�•�``• REV=6/20/07 ALR REPAIR FOR BROKEN WEB/CHORD 1a REPAIR: (REF. NDS-91 1) SHORE TRUSS TO PROPER LEVEL 2) REALIGN BROKEN WEB . 3) APPLY APPROPRIATE SCAB AND NAILING AS INDICATED IN TABLE BELOW: SCAB SHALL BE OF THE SAME SIZE, GRADE, AND SPECIES AS THE WEB MEMBER (U.N.O.) OR BETTER. ALL NAIL VALUES ARE BASED UPON PNEUMATIC DRIVEN 10d GUN NAILS AND S.Y.P. LUMBER. NOTE: NAILS SHALL BE DISTRIBUTED SO THAT THE END DISTANCE, EDGE DISTANCE, AND SPACING WILL AVOID UNUSUAL SPLITTING OF THE WOOD. TOTAL NAILS (1 Od GUN) CHORD/WEB FORCE (LBF.) MIN. SCAB LENGTH (FT.) 12 672 # 1'-6" 16 896 # 2'-0" 20 1120 # 2'-4" 24 1344 # 2'-8" 28 1568 # 3'-0" 32 1792 # 3'-4" 36 2016 # 3'-8" 40 2240 # 4'-0" 44 2464 # 4'-4" 48 2688 # 4'-8" 52 2912 # 5'-0" 56 3136 # 5'-4" 60 3360 # 5'-8" 64 3584 # 6'-0" 68 ' 3808 # 6'-4" 72 4032 # 6'-8" 76 4256 # 7'-0" 80 4480 # 7'-4" 84 4704 # 7'-8" 88 4928 # 8'-0" *92 5152 # 8'-4" *96 5376 # 8'-8" * 100 5600 # 9' —0" * 104 5824 # 9' — 4" * 108 6058 # 9'-8" USE 2x6 MIN. SCAB SIZE FOR THESE. el NOTE: SCAB BOTH SIDES, SAME SIZE & SPECIES OF WEB/CHORD. TOTAL NAILS INCLUDE BOTH SCABS. STRESS INCREASE = 1.14 OR 112#/NAIL. 1 /2 MIN. LENGTH NAILED TO UNDAMAGED SECTION REF. TO ** NOTE BELOW - BREAK NOTE: ** INCREASE MIN. LENGTH AS REQ'D TO HAVE 1 / 2 LENGTH NAILED INTO UNDAMAGED SECTION. QN REPRESENTS THE TOTAL NUMBER OF NAILS REQUIRED FOR SCABS ON BOTH SIDES. NAILS SHALL BE EVENLY DIVIDED BETWEEN BOTH SCABS AND ON EACH SIDE OF BREAK. SPACE COAST TRUSS, INC. 1410 WHITE DR. TEL: (321)-633-7511 TITUSVILLE, FLORIDA 32780 FAX: (321)-633-7544 NORTH WEST FLORIDA SOUTH FLORIDA PLANT NORTH EAST FLORIDA 3222 N.E. 24TH STREET 9500 W. ATLANTIC AYE. 105 DENVER ROAD OCALA, FLORIDA 34470 DELRAY BEACH, FL 33446CRESCENT CITY, FL 32112 No. 47182 -o STATE OF 0 R \- Em REV=6/20/07 ALR SPACE COAST TRUSS, INC. 1410 WHITE DR. TEL: (321)-633-7511 TITUSVILLE, FLORIDA 32780 FAX: (321)-633-7544 NORTH }VEST FLORIDA SOUTH FLORIDA PLANT NORTH EAST FLORIDA EST. 1989 3222 N.E. 24TH STREET 9500 W. ATLANTIC AVE. 105 DENVER ROAD OCALA, FLORIDA 34470 DELRAY BEACH, FL 33446 CRESCENT CITY, FL 3211 27-8-0 Tif,F *** NOTES *** AS AN ADDITION, IT - IS THE BUILDERS RESPONSIBILITY TO VERIFY ALL: WALL HEIGHTS, PITCHES, OVERHANGS, CANTILEVERS, HEEL HEIGHTS, END CONDITIONS AND DIMENSIONS PRIOR TO FABRICATION OF TRUSSES. Revision Notes Chang Date 1#1 Changes Made I By 7/07/00 11 IREVISED SPAN & PITCH PER REVIEW I MR Lji WHILE EVERY ATTEMPT HAS BEEN MADE TO PRODUCE A FLAWLESS PLACEMENT DIAGRAM FOR THIS THIS DIAGRAM IS INTENDED FOR USE BY PERSONS KNOWLEDGEABLE IN AND FAMILIAR WITH GENERALLY ANY AND ALL REPAIRS/ALTERATIONS TO ANY TRUSS MUST BE APPROVED AND ACCEPTED BY A W PROJECT, THE POSSIBILITY FOR SMALL ERRORS DOES EXIST, CONSEQUENTLY, IT IS VITALLY IMPORTANT ACCEPTED METHODS AND STANDARDS OF TRUSS ERECTION. REPRESENTATIVE OF SPACE COAST TRUSS. THAT THE BUILDER CAREFULLY REVIEW AND CHECK ALL DETAILS AND INFORMATION. TRUSS ERECTION SHOULD NOT BE ATTEMPTED BY ANY PERSON WITHOUT THESE QUALIFICATIONS. ANY BACK CHARGES THAT ARE NOT HANDLED IN THE ABOVE MENTIONED MANNER ARE SUBJECT TO MANY ERRORS OR OMISSIONS SHOULD BE REPORTED IMMEDIATELY TO SPACE COAST TRUSS. TRUSS ERECTION AND BRACING RESPONSIBILITIES MUST LIE WITH THE BUILDER. REVIEW AND POSSIBLE REJECTION. DO NOT SCALE DRAWINGS. DO NOT CUT. MODIFY. OR ALTER ANY TRUSSES. IN THE EVENT THAT A TRUSS. NEEDS DO NOT USE THIS DIAGRAM TO SET TRUSSES UNLESS IT -IS MARKED TRUSS PLACEMENT DIAGRAM. U WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. ALL INTERIOR LOAD BEARING WALLS MUST BE STANDING AND PROPERLY BRACED PRIOR TO MODIFICATION OR ALTERATION, IT IS THE RESPONSIBILITY OF THE BUILDER TO NOTIFY A WHEN TRUSSES ARE DELIVERED TO THE JOB SITE THERE WILL BE A PACKAGE CONTAINING A LAYOUT SPACE COAST TRUSS EMPLOYEE WHO IS EXPERIENCED IN THE FIELD OF REPAIRS. PRIOR TO AND COMPLETE TRUSS ENGINEERING. PLEASE REVIEW THE ENTIRE CONTENTS OF PACKAGE BEFORE SETTING ANY AND ALL TRUSSES. q SUBMITTING ANY BACK CHARGE FOR THE SAID REPAIR(S). SETTING TRUSSES. CUSTOMER: PROJECT/RESIDENCE: MODEL: DATE: SCALE: TRUSS DESIGN BY: CAD DRAWN BY: PITCH: O.H. / . CANT: RF/FLR LOADING: WIND SPEED: WIND DSGN METHOD: EXP. CATEGORY: OPENING COND: OCCUP. GROUP: OCCUP. CATEGORY: BLDG CODE: PAUL DAVIS RESTORATION THIERY THIERY ADDITION 06/25/08 1/4"=V-D", 11x17=N.T.S. MARK REID JESSICA TORRES 3/12 24" PLUMB 20-7-0-10 1.25 140 MPH ASCE 7-05, C.C. & M.W.F.R.S. C ENCLOSED RESIDENTIAL H FBC 2004 TPI 2002 8'-0" PLATE HGT. USP TRUSS to TRUSS CONNECTOR SCHEDULE "FOLLOW HANGER MANUFACTURER INSTALLATION RECOMMENDATIONS FOR HANGER CONNECTION" ANY MODIFICATION OF EXISTING ROOF TRUSS SYSTEM IS THE RESPONSIBILITY OF THE PROFESSIONAL BUILDING DESIGNER AND ENGINEER OF RECORD. SPACE COAST TRUSS INC. STRONGLY RECOMMENDS THE USE OF A SPREADER BAR FOR TRUSS SPANS GREATER THAN 30'IN LENGTH. REFER TO BCSI-1 SUMMARY SHEET. THIS IS A TRUSS PLACEMENT DIAGRAM ONLY WHEN THIS LAYOUT IS SIGNED AND SEALED BY THE TRUSS DESIGN ENGINEER AS THE TRUSS DESIGN ENGINEER IS NOT INTENDED TO RELIEVE THE TRUSS SYSTEM ENGINEER AND/OR THE ENGINEER OF RECORD FROM REVIEWING AND APPROVING THIS DOCUMENT. DIMENSION EXPLANATION 2-0-12 4-2-8 2-0-12 FEET - INCHES -16 the FOUR FEET, 2 INCHES �7WO FEET, ZERO INCHES, AND 8/16ths, OR IJT AND 12/161hs, OR 3/4' CONNECTOR EXPLANATION INDICATES "HANGER TYPE APPLIES FOR THIS SERIES OF TRUSSES" A B INDICATES "HANGER TYPE FOR THIS TRUSS ONLY" SPACE COAST TRUSS INC. * 1410 WHITE DRIVE TITUSVILLE, FLORIDA 32780 PHONE: (321) 633-7511 EST. 1989 FAX: (321) 633-7544 TRUSS DESIGN ENGINEER MANUEL MARTINEZ FL. PE S 47I82 TRUSS DESIGN ENGINEER STEPHEN W. WARTER FL PE 54395 Q V' M 01 co 0 N r4 N n a 3 v, N u1 0 0o CD 3 i N 0 0 0 11 a` ii MIN, SETBACK REQ. DRAIN FIELD* FRONT 5 SIDES rl rJ N CNR SIDESSD c REAR ZNG. u �� -TECH.. LOT 38 WELL (OCCUPIED) FND 5/8" IR INDIAN RIVER ESTATES UNIT NINE PLAT BOOK 10, PAGE 74 ST LUCIE COUNTY, FLORIDA FEN CORP •� 0.3' N/0.1' E; � (J LOT 18 70 (OCCUPIED) D- _}I o WELL O PROP STj \ 19' % z 21.92' , w t. t N i 1 -- 6' WD o $T �-� FEN CDR 112.85*, 9.00 0.4' N/59.6' E 5' CL 3 /l$_ n c� r N w O $ O J O / 12.81' a DRAN FIELD± FND 1/2" IP FND 1/2" "NO ID" "NO ID NO0'00'0O" 00'(P) ,- — nn PERK LOT 39 (VACANT) 80.00'(P g1 FND 1/2" IP SPECIAL PURPOSE PLOT PLAN IIIESST. LUcit ::r, t`d l RLT IDEPT SITS NAA FPPROVE) FOR CONSTo LOT AO §�PEACEp an O�rS SIM (VACANT) j s FOR omsc2 A��►�Eu�R: � Q _ ._ 0_7' S/11.FENz W LIMITS OF PLAT LOT 19 I BLOCK 65 PROPSED DRAN�ELD M LOT 20 625 SF I d �. (OCCUPIED) Lo N 9 3108'- O 27?f1f1 z P P"bSED AgoomoN &TIT 38` \ \ \� N 52.77' 5' CL m FEN CDR 1.6' S/59.5' E \ 3 \ J EXISTING 4 STORY WOOD/CB$ RESIDENCE N " p \\ o . 1g1 >al p O '� G OO \ 17.75' O 20.57' i M WOVERE » 14.35' R Z 4.42' PROPOSED E PORCH 30.00, e 9.9' N CONC LL DRIVE I e I /ELL ,��• L *00'011W 80.0 '(P ) FND 1/2" IP 155.00'(P) jtgp 1 "NO ID" 155.07'(M) I WM ' o f i \ EP LEGAL DESCRIPTION: LOT 19, BLOCK 65, INDIAN RIVER ESTATES UNIT EIGHT, AS RECORDED IN PLAT BOOK 10, PAGE 73, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. ADDRESS: 5900 SUNSET BOULEVARD FORT PIERCE, FLORIDA N OTES: SUBJECT TO ANY APPLICABLE EASEMENTS, RIGHTS -OF -WAY, OR OTHER RESTRICTIONS OF RECORD. A SEARCH OF THE PUBLIC RECORDS HAS NOT BEEN MADE BY THIS OFFICE. BEARINGS SHOWN ARE RELATED TO THE CENTERLINE OF SUNSET BOULEVARD, AS SHOWN ON THE PLAT OF RECORD. LEGAL DESCRIPTION PROVIDED BY CLIENT. ELEVATIONS ARE IN FEET AND RELATED TO THE BENCHMARK SHOWN HEREON. PROPERTY LIES IN F.I.R.M. ZONE "AH" (BASE FLOOD ELEVATION 17.0'), AS SHOWN ON PANEL 120285-0281G, DATED 11/4/92. FLOOD ZONES ARE APPROXIMATE AS SCALED FROM FLOOD INSURANCE RATE MAPS. IN ACCORDANCE WITH CHAPTER 611317-6.003, ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY, IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY. THERE ARE NO ABOVE GROUND ENCROACHMENTS UNLESS OTHERWISE SHOWN. UTILITIES SHOWN HEREON ARE VISIBLE ABOVE GROUND FEATURES. ADDITIONAL SUBSURFACE UTILITIES AND OR FEATURES MAY EXIST. THERE MAY BE ADDITIONAL RESTRICTIONS THAT ARE NOT SHOWN ON THIS SURVEY, THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. THIS PLAN INFORMATION TO BE VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. AFTER 90 DAYS FROM THE LAST FIELD DATE, THIS SURVEY WILL NEED TO BE UPDATED FOR A CURRENT SEAL AND SIGNATURE. CERTIFIED TO: PAUL DAVIS RESTORATION & MODELING TEAM WI ROBERT F. KEMERSON FND 8" IR PROFESSIONAL SURVEYOR AND MAPPER "NO ID STATE OF FLORIDA # 6285 VELCON GROUP, INC. P A U L D In RESTORATION & MOD Q o REVISIO m I� %� V �7 NO. DESCRIPTION 25.00' I 1 mni Imneav _ h 80.00 P _ EP 130.00 (P) Z N00'00'00"E \ 210.00'(P) / 20' ASPHALT SUNSET BOULEVARD 80' RAV \ BMNC-VD / SEE REVERSF SIDE FOR ELEV=18.00\ - SYMBOL LEGEND AND ~� `ET PKNAIL —� ABBREVIATION SCHEDULE w r SYMBOLEEGEND POWER POLE T R TELEPHONE RISER ® WATER METER CONCRETE POWER POLE *{ x EXISTING ELEVATION F-I CONCRETE MONUMENT O SET ROD & CAP LB# 4942, UNLESS OTHERWISE NOTED O FOUND MARKER AS NOTED d DELTA ANGLE E- GUY ANCHOR PROPOSED ELEVATION 0 SANITARY MANHOLE QD DRAINAGE MANHOLE (4:1 SLOPES ' ARE MAXIMUM) ABBREVIA TIONS A/C AIR CONDITIONING FDC FIRE DEPARTMENT CONNECTION PCP PERMANENT CONTROL POINT AC ACRE ` -. FECRR FLORIDA EAST COAST RAILROAD PF - PLASTIC FENCE AL ALUMINUM FFE FINISHED FLOOR ELEVATION PG PAGE AMC ANCHOR • F7I FIRE HYDRANT PI POINT OF INTERSECTION AP ANCHOR .POLE FIVD FOUND PK&D PARKER KALON NAIL AND DISK _ AP,RX . APPROXIMATE., FOC FACE OF CURB PK/TT PARKER KALON NAIL AND TIN. TAB , ASR _.. _ ASPHALT - FOW FACE OF WALK PLS PROFESSIONAL L4TVD SURVEYOR BE BUFFER. EASEYF_NT FPL FLORIDA POWER & LIGHT POB POINT OF BEGINNING - BFP '' BACK `FLOW `PREYENTOR GA GREEN AREA POC POINT OF •COMMENCEMENT • ._ . -. BLDG - BUILDING= .- _ : - . GUN GAS MANHOLE PP POWER POLE `BLk BLOCK ' ' `. :, GND GROUND PRC POINT OF REVERSE CURVATURE .BM- BENCHMARK"' ' GRD GRINDER PRO PRORATED DISTANCE _ BOC BACK OF CURB HC HEADER CURB PROP PROPOSED BP,' BRICK PAVERS HOPE HIGH DENSITY POLYETHYLENE PRY PERMANENT REFERENCE MONUMENT BOW - BACK OF WALK. HGW HOG WIRE PSM PROFESSIONAL SURVEYOR & MAPPER BRG ;'.. BEARING HW HEADWALL PSWL PLASTIC SCALE BW BARBED WIRE HYD HYDRANT PT POINT OF TANGENCY C&G CURB AND GUTTER /CV IRRIGATION CONTROL VALVE PUE PRIVATE UTILITY EASEMENT C&T CULPEPPER & TERPENING ID IDENTIFICATION PVC POLYVINYL CHLORIDE C/O CUT OUT ILL ILLEGIBLE R/C ROD AND CAP C CALCULATED TNT INTERSECTION R/W RIGHT-OF-WAY CATV CABLE TELEVISION BOX /NV INVERT R RADIUS CB CATCH BASIN lP IRON PIPE RCP REINFORCED CONCRETE PIPE CBS CONCRETE BLOCK STRUCTURE IP&P IRON PIPE & PLUG RGE RANGE CHD CHORD IR IRON ROD RLS REGISTERED LAND SURVEYOR Cl CURB INLET /W IRRIGATION WELL RP RADIUS POINT CL CENTERUNE L LENGTH RR RAILROAD CLF CHAIN LINK FENCE LB LICENSED BUSINESS RRS RAILROAD SPIKE CM CONCRETE MONUMENT LF7S LIFT STATION S/W SIDEWALK CUP CORRUGATED METAL PIPE LYE LAKE MAINTENANCE EASEMENT SAN SANITARY SEWER MANHOLE CO CLEAN OUT LOC LOCA770M SOT SOUTHERN BELL TELEPHONE COR CORNER LP LIGHT POLE SEC SECT70M CONC CONCRETE LS LICENSED SURVEYORS , SF SQUARE FEET CONST CONSTRUCTION M MEASURED SHP SHIP SPIKE OR BOLT COV COVERED MAX MAXIMUM ` SLP STREET LIGHT SUPPORT POLE CE COVERED ENTRY MB hwL BOX = "''""" ` SMH SANITARY MANHOLE COVP COVERED PORCH MEAS MEASURED SPC STATE PLANE COORDINATES CPP CONCRETE POWER POLE UES MITERED END: SECTION STY STORY CPPIPE CORRUGATED PLASTIC PIPE MH MAN HOLE - ST SEP77C TANK CS CONCRETE SLAB MHWL MEIN HIGH WATER LEVEL SV SANITARY VALVE A DELTA ANGLE MIN MINIMUM SWL SCALE D/F DRAIN FIELD MN IWAGNE77C NAIL TA TOP OF ASPHALT D DEED INFORMATION MIT MITERED END: TM TAX MAP DC 'D" CURB MW MONITORING WELL TUH TELEPHONE MANHOLE . DE DRAINAGE EASEMENT N&D NAIL AND DISK TOO TOP OF BANK DI DROP INLET N NAIL TOE TOE OF SLOPE DM DIAMETER NA NON APPLICABLE TP TRAVERSE POINT DIP DUCTILE IRON PIPE NAVD NORTH AMERICAN VERTICAL DATUM TR TELEPHONE RISER DMH DRAINAGE MANHOLE NGVD NATIONAL GEODETIC (rERTICAL DATUM TRANS TRANSFORMER DUE DRAINAGE & UTILITY EASEMENT NO NUMBER TSB TRAFFIC SIGNAL BOX EC EDGE OF CONCRETE NTS NOT TO SCALE TT 77N TAB ECP ELECTRICAL CONTROL PANEL O/A OVERALL TWNP TOWNSHIP EL ELEVATION O/S . OFFSET TYP TYPICAL ELEC ELECTRIC. OE OVERHEAD EASEMENT U/C UNDER CONSTRUCTION ELEV ELEVA7ON OHE OVERHEAD ELECTRIC UE U77LITY EASEMENT EM ELECTRIC METER OHU OVERHEAD UTILITY UP U77LITY POLE ENC ENCROACHMENT OR OFFICIAL RECORD UR UTILITY RISER EOW EDGE OF WATER ORB OFFICIAL RECORD BOOK UW UNDER WATER EP EDGE OF PAVEMENT P/C PROPERTY CORNER VC VALLEY CURB ESB ELECTRIC SERVICE BOX P/L PROPERTY LINE VLT VAULT ESMT EASEMENT P PLAT WD WOOD EXIST EXISTING PAVE PAVEMENT WL WATER LINE EXT EXTENDED PB PLAT BOOK WM WATER METER F FENCE PC POINT OF CURVATURE WP WELL POINT FC 'f " CURB PCC POINT OF COMPOUND CURVATURE WPP WOOD POWER POLE PCO PRESSURE CLEAN OUT (SANITARY) WV WATER VALVE C 40 P 043 -b D LEGAL DESCRIPTION: ?�r �LUCe C LOT 19, BLOCK 65, INDIAN RIVER ESTATES UNIT EIGHT, AS RECORDED IN PLAT SCALE 1"=30' p0f O, F BOOK 10, PAGE 73, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. DRAIN FIELD± i proved ADDRESS: 5900 SUNSET BOULEVARD PUBLIC WORKS I FORT PIERCE, FLORIDA ST. LUCIE COU N'TM FL LOT 38 WELL (OCCUPIED) FND 5/8" IR INDIAN RIVER ESTATES UNIT NINE PLAT BOOK 10, PAGE 74 ST LUCIE COUNTY, FLORIDA LOT 39 (VACANT) FEN CORIJ 1. t J V S. l LOT 18 � (OCCUPIED) ; f �'L- j ,\ o O WELL � cli , t \ in \n $T FORmB6ARDS i TOP' =19.66 _— 6, FEN CDR x 0.4' N/59.6' E 12.85'A 9.30' 5' C 52.77' N. n / 41 O.' �/ vp LJ /f EXISTING d STORY n O / N WOOD/CB$ RESIDENCE \ O / n FFY=19.66 01.1 / Zf 20.57' 0 17.75' I , 12.61' 3' CONC WALK DRAN FIELD± FND 1 2" IP FND 1 2" I 1 "NO l I "NO ��L ID" IDT NO SUNSET BOULEVARD LOT 40 (VACANT) *1 FND 1/2" IP 00' P&M ` "NO ID" FEN COR 0.7' S/1.2' W } LIMITS OF PLAT LOT 19 BLOCK 65 LOT 20 (OCCUPIED) to O to *� 14.3B' FEN CDR m \ 5' C o' vi n p \ / O \ • O ` P 14.35' 14.42' Z � •'1 ti T�5 � in 9.9, N CONC y DRIVE �� �� I N00'00'PO"W 80.0 '(P M) WPP FND 1/2" IP 155.00 (P) "NO ID" 155.07'(M) wM '} o ; • o % \ d EP 80.00' P _ EP 130.00'(P) f` 1\100'00'00"E \ 210.00'(P) / 20' ASPHALT I� uj uj 1 � FND I �0 �o Q: Q O m I0 25.00' (P) J 80 R / vv--, BMNc ; -: SEE REVERSF SIDE FOR ELEV-� 0'� % SYMBOL LEGEND AND SET PK NAIL ABBREVIATION SCHEDULE NOTES: SUBJECT TO ANY APPLICABLE EASEMENTS, RIGHTS -OF -WAY, OR OTHER RESTRICTIONS OF RECORD. A SEARCH OF THE PUBLIC RECORDS HAS NOT BEEN MADE BY THIS OFFICE. BEARINGS SHOWN ARE RELATED TO THE CENTERLINE OF SUNSET BOULEVARD, AS SHOWN ON THE PLAT OF RECORD. LEGAL DESCRIPTION PROVIDED BY CLIENT. ELEVATIONS ARE IN FEET AND RELATED TO THE BENCHMARK SHOWN HEREON. PROPERTY LIES IN F.I.R.M. ZONE "AH" (BASE FLOOD ELEVATION 17.0'), AS SHOWN ON PANEL 120285-0281G, DATED 11/4/92. FLOOD ZONES ARE APPROXIMATE AS SCALED FROM FLOOD INSURANCE RATE MAPS. IN ACCORDANCE WITH CHAPTER 611317-6.003, ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY, IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY. THERE ARE NO ABOVEGROUND ENCROACHMENTS UNLESS OTHERWISE SHOWN. UTILITIES SHOWN HEREON ARE VISIBLE ABOVE GROUND FEATURES. ADDITIONAL SUBSURFACE UTILITIES AND OR FEATURES MAY EXIST. THERE MAY BE ADDITIONAL RESTRICTIONS THAT ARE NOT SHOWN ON THIS SURVEY, THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. THIS PLAN INFORMATION TO BE VERaFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. AFTER 90 DAYS FROM THE LAST FIELD DATE, THIS SURVEY WILL NEED TO BE UPDATED FOR A CURRENT SEAL AND SIGNATURE. CERTIFIED TO: PAUL DAVIS RESTORATION & MODELING TEAM C�� l ROBERT F. KEMERSON PROFESSIONAL SURVEYOR AND MAPPER L IR STATE OF FLORIDA # 6285 1 VELCON GROUP INC. V G 'V�K ENGINEERS & SURVEYORS 702 S. W. PORT ST. LUCIE BLVD. PORT ST. LUCIE, FLORIDA 34953 (772) 879-0477 (772) 871-6659 (FAX) LICENSE BUSINESS 14942 PAUL DAVIS RESTORATION & MODELING TEAM REVISIONS NO. DESCRIPTION DATE BY 1 BOUNDARY 06/30/08 SE 2 FORMBOARD 08/27/08 BK 3 )ATE IN FIELD: CHECKED BY: 06/25/08, 08/26/08 BK FIELD BOOK: PACE; I JOB NO.: 08-05 23-24 08-052 w Q SYMBOL LEGEND POWER POLE T R TELEPHONE RISER ® WATER METER CONCRETE POWER POLE �+ x EXISTING ELEVATION F. I CONCRETE MONUMENT O SET ROD & CAP LB# 4942, UNLESS OTHERWISE NOTED O 1 FOUND MARKER AS NOTED. DELTA ANGLE E- GUY ANCHOR PROPOSED ELEVATION GS SANITARY MANHOLE QD DRAINAGE MANHOLE (4:1 SLOPES ARE MAXIMUM) =� ABBREVIATIONS A/C AC AL AMC AP APRX ASP BE BFP BLDG BLK BM BOC BP BOW BRG BW C&G C&T C/o C CAN CB CBS CND CI CL CLF CM CUP CO COR CONC CONST CoV CE COVP CPP CPPIPE CS A D/F D DC DE DI D14 DIP DUH DUE EC ECP EL ELEC ELEV EU ENC EOW EP ESM ET EXIST EXT F FC AIR COND1770MING ACRE ALUMINUM ANCHOR ANCHOR POLE APPROXIMATE ASPHALT BUFFER EASEMENT BACK FLOW PREVENTOR BUILDING BLOCK BENCHMARK BACK OF CURB BRICK PAVERS BACK OF WALK BEARING BARBED WIRE CURB AND GUTTER CULPEPPER & TERPENING CUT OUT CALCULATED CABLE TELEVISION BOX CATCH BASIN . CONCRETE BLOCK S7RUCTURE CHORD CURB INLET CEN7ERLINE CHAIN LINK FENCE CONCRETE MONUMENT CORRUGATED METAL • PIPE CLEAN OUT - CORNER CONCRETE CONSTRUCTION COVERED COVERED ENTR COVERED PORCH CONCRETE POWER POLE CORR_'r,ATED PLAS77C PIPE CONCRETE SLAB DELTA ANGLE DRAIN FIELD DEED INFORMATION 'D" CURB DRAINAGE EASEMENT DROP INLET DIAMETER. DUCTILE IRON PIPE DRAINAGE MANHOLE DRAINAGE & UTILITY EASEMENT EDGE OF CONCRETE ELECTRICAL CONTROL PANEL ELEVA770N ELEC774IC ELEVATON ELECTRIC METER ENCROACHMENT EDGE OF WATER EDGE OF PAVEMENT ELECTRIC SERVICE BOX EASEMENT EXIS771VG EXTENDED FENCE F" CURB FDC FIRE DEPARTMENT CONNECTION PCP PERMANENT CONTROL POINT FECRR FLORIDA EAST COAST RAILROAD PF PLASTIC FENCE FFE FINISHED FLOOR ELEVATION PG PAGE FH FIRE HYDRANT PI POINT OF INTERSECTION FNO FOUND PK&D PARKER KALON NAIL AND DISK FOC FACE OF CURB PK/TT PARKER KALON NAIL AND 77N TAB FOW FACE OF WALK PLS PROFESSIONAL LAND SURVEYOR FPL FLORIDA POWER & LIGHT POB POINT OF BEGINNING GA GREEN AREA POC POINT OF COMMENCEMENT GMH GAS MANHOLE PP POWER POLE GND GROUND PRC POINT OF REVERSE CURVATURE GRD GRINDER PRO PRORATED DISTANCE HC HEADER CURB PROP PROPOSED HOPE HIGH DENSITY POLYETHYLENE PRM PERMANENT REFERENCE MONUMENT HGW HOG WIRE PSM PROFESSIONAL SURVEYOR & MAPPER HW HEADWALL PSWL PLASTIC SWALE HYD HYD24NT PT POINT OF TANGENCY /CV IRRIGATION CONTROL VALVE PUE PRIVATE UTILITY EASEMENT 1D IDENTIFICATION PVC POLYVINYL CHLORIDE ILL ILLEGIBLE R/C ROD AND CAP 1NT INTERSECTION R/W RIGHT-OF-WAY INV INVERT R RADIUS lP IRON PIPE = RCP REINFORCED CONCRETE PIPE 1P&P IRON PIPE & PLUG RGE RANGE IR IRON ROD RLS REGISTERED LAND SURVEYOR /W IRRIGATION WELL RP RADIUS POINT L LENGTH RR RAILROAD LB LICENSED BUSINESS RRS RAILROAD SPIKE LFTS LIFT STAT TON S/W SIDEWALK LME LAKE MAINTENANCE EASEMENT SAN SANITARY SEWER MANHOLE LOC LOCATION SOT SOUTHERN BELL TELEPHONE LP LIGHT POLE SEC SECnoN LS LICENSED SURVEYOR SF SQUARE FEET M MEASURED SHP SHIP SPIKE- OR BOLT MAX MAXIMUM SIP STREET_-LIGIjLSUP -ORLP_OLE GIB L BOX SMH SANITARY MANHOLE MEAS MEASURED SPC STATE PLANE COORDINATES MES MITERED END SECTION STY STORY MH MAN HOLE ST SEPTIC TANK MHWL MEAN HIGH WATER LEVEL SV SANITARY VALVE MIN MINIMUM SWL SWALE MN MAGNETIC NAIL TA TOP OF ASPHALT MIT MITERED END TM TAX MAP MW MONITORING WELL TMH TELEPHONE MANHOLE N&D NAIL AND DISK TOB TOP OF BANK N NAIL TOE TOE OF SLOPE NA NON APPLICABLE TP TRAVERSE POINT NAVD NORTH AMERICAN VERTICAL DATUM TR TELEPHONE RISER NGVD NATIONAL GEODETIC (%ERTICAL DATUM TRANS TRANSFORMER NO NUMBER TSB TRAFFIC SIGNAL BOX NTS NOT TO SCALE TT 77N TAB O/A OVERALL TWP TOWNSHIP O/S OFFSET TYP TYPICAL OE OVERHEAD EASEMENT U/C UNDER CONST RUCT70N ONE OVERHEAD ELECTRIC UE U77LITY EASEMENT OHU OVERHEAD UTILITY UP U77LITY POLE OR OFFICIAL RECORD UR UTILITY RISER ORB OFFICIAL RECORD BOOK UW UNDER WATER P/C PROPERTY CORNER VC VALLEY CURB P/L PROPERTY LINE VLT VAULT P PLAT WD WOOD PAVE PAVEMENT WL WATER LINE PB PLAT BOOK WM WATER METER PC POINT OF CURVATURE WP WELL POINT PCC POINT OF COMPOUND CURVATURE WPP WOOD POWER POLE PCO PRESSURE CLEAN OUT (SANITARY) WV WATER VALVE