Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSDate: a?It4JL R' Fee Due: Receipt# Permit # s 5 �y SCANNEBSt. Lucie County Building & Zoning Ac xAcAre ® •ice By 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 TG n f'v ` • Fl{r St. Lucie Coup Tel. 772-462-1553 f!C � OR10 �% APPLICATION FOR ROOF PERMIT SEE REVERSE SIDE FOR INSTRUCTIONS 1. Location/Site Address: 7 / �1� C 1 J} t� �►.. v +e 2. Parcel ID Number: 2 LV-L.1- (fl Office Use Only Section Township Range Ma Page ZoningLand Use Initials oZ l 3 .40 64 rt S U � 3. Description of Project or Work Activity: �� o o l=3 L� �- c% r fib 4. Total Roof Area (square feet): 20 op 5. Roof Pitch: 6. Type of Roof: ❑ F!bglass Shingle ElBarrel/Tile Ceramic ElWood Shake Shingle 1Zr & Gravel ❑modified Bitumen ❑ Metal ❑ Other (specify) N.O.A —Product Approval required for All Types of Roofing Material ❑ All Commercial Roofing Requires Design by an Engineer or Architect (two Sets) 7. Owner Information 8: Contractor Information Name: UU 0 1 I i�M `.v a )_ FL Reg/Cert #: Address: ���� ��►1� V� City: FG(4 f t,ere%,e State: FL :County Cert#: 1 9 $ 6 L Business Name:��n Zip:. Phone: L) 6 3)D Phone NIA Fax 9. Value of Construction: $ 'Vo le0 Note: Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. 0 e Y-K PRINT QUALIFIERS/OWNERS N ME SIGNATURE OF QUALIFIERIOWNERL r STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS �'i DAY OF 111311 4NOTARY WHO Is PERSONA Y KNOWN TO ME OR O HASP ��ER AENTIFIC N. /o, COMM1S�®b uO�J 1U aer++Co `s ev\*Jt5Nd-,, pubs\C NAOF NOTARY TYPE N NAME OF NOTAR;,.�y, g0 TITLE:LIC COMMISSION NUMB St. Lucie County Roof Permit Application rev. 7/18/05 dmg s 1 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT: EXEMPT: A/C - HEAT REPLACEMENT WITH CONTRACT UNDER $5,000. INSTRUCTIONS Please complete all information in the space provided. All information must be printed (use black or blue ink only) or typed. This roof permit application is to be used only for those activities that are not otherwise. included under a primary building permit. This application may not be used for any activity that includes structural alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted through the regular building permit review process: The. information to be provided with this application includes: 1. Location/Site Address Indicate the street address or general location of the property where the building activity is taking place. 2. Parcel ID Number Indicate the tax identification number of the property where the building activity is taking place. 3. Description of Project or Work Activity Briefly describe the building activity to take place. 4. Total Roof Area Indicate total roof area to be affected by this permit. Also indicate the pitch of the roof, expressed as a standard ratio of run rise. 5. Type of Roof Indicate the type of roof being repaired or resurfaced. 6o Owner Information Indicate the name and address of the owner of the property on which building activity is taking place. 7. Contractor Information Indicate the State of Florida registration number (if applicable), St. Lucie County contractor license number and the name of the business doing the work. 8. Value of Construction Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated withthe building/construction activity. Construction value is used to determine the permit fee. St. Lucie. County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce, FL 34982. All permit applications must be filled out completely before submission. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Upon issuance of this permit, required inspections, can be scheduled by calling (772) 462-1261. St. Lucie County Roof Permit Application rev. 7/18/05 dmg EDWIN M. FRY, Jr., CLE' �)F THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3231378 OR BOC:,_ , 494 PAGE 788, Recorded 07/14/2008 ai'``):33 AM PERMIT NUMBER �;OTIGE ^e rtn1L�t14FN�EMENT The undersigned hereby given notice that Improvement will be made to certain real property, and in accordance with Chapter 713. Florida Statutes the following information Is provided in the Notice of Commencement. 0019 1. DESCRIPTION OF PROPERTY (Legal description and street address, W available) TAX FOLIO NUMBER 2421-606 0022-0UNIT SUBDIVISION Corso Courts BLOCK TRACT LOT BLDG South 1/2 of lot 22 and all of lot 23 2. GENERAL DESCRIPTION OF IMPROVEMENT: Reroof Residence 3 Ply Tar 8 gravel umn..... 1 Wn1E ITRt 3. OWNER INFORMATION: a. Name : uyrram L—W .---- c. Interest in property : @@81dPJGli b. Address 2718 Placid Avenue Fort Pierce FI 34982 d. Name and address of fee simple titleholder (W other than Ownerj 4. CONTRACTOR'S NAME. ADDRESS AND PHONE NUMBER: R & M ROOFING 629 S. MARKET AVE FT PIERCE FL 34982 T72 484 8419 5. SURETY'S NAME, ADDRESS AND PHONE NUMBER AND BOND AMOUNT: 6. LENDER'S NAME, ADDRESS AND PHONE NUMBER: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: e fallowing to receive a copy of the Uenor s Notice as provided In Section 8. In addition to himself or herself, Owner designates tls 713.13(1)(b), Florida Statutes: NAME, ADDRESS AND PHONE NUMBER: 9. Expiration date of notice of commencement (the e)cplration date is 1 year from the date of recording unless a different date Is snecifiedl: 1213112008 Print Name and Provide Signatory s I 1---ftice Signature of Owner or Owners Authorized Officer/9rector/Partner/Menager State of Florida County of _20 The foregoing instrument was acknowledged before me this da ofYj1L-1*N i s ) 1' iGi�V1 L (1JC) IT as e. ,totRicer,trustee,attorneyInfart) By (type of autharhy, ... g" (name of person) For (name of party on behalf of who nsWment was executed) o ro ueed the following type of Identification: LHOY ryNotary Pu,k Bl to of Florida (Signature of Notary Public) 3� MY CommIsWm Espies Feb S, 201t yj a' CommIssion 0 D M820 a foregoing and that the facts in W ere true to the best of my knowledge and Under en1�&Pe�lMe0di01iRl belief Slgnature(s) of Ownar(s) or Owners) Authorized Offlcar)Directorl Panne r/Manager who signedabove'. By D�� By ( STATE OF Ft,O II�A ST. LUGiE IJNTY T H I CEi T!F%' NAI THIS IS A J 12 s .� ,. , Dale: Notary Public, State of Flori Signature of Notary:'It lJ� Commission No.:n#DD� I.indB Wi1s80151 1 '-Plies: JUKE 29, 2012 BONDED nMU ATLANTIC HORDING CO., INV. cml 9/27/07 Public Works Department Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 INSPECTION AFFIDAVIT G�'o7 RE: Permit # (1-� -- ©b I P o c, r` 14 Y ,e o � LN ,licensed as a( Contractor /Engineer/Architect/ (Please print name and circle license type) FS 468 Building Inspector* * General, Building, Residential, or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. All affidavits must include photographs of each plane of the roof with the permit # or address # clearly shown marked on the deck for each inspection. On or about rD R I 'D'Oo , I did personally inspect the roo ate & time) n deck nail nd/or seconddry water barrier work at (circle ope) (Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S.) Cz.- ti�2L� C�_ DSO��g Signatig & Seal License # STATE OF FLO DA COUNTY OF Sworn to and subscribed before me this day of .200 0 by I t 1 Who is personally known o as produced REG�' - - as-rdetrtt t-t�on. 3 p INSAvg p19c Work' gt. Lucie C°untY (Seal) Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 http://stlucleco.gov/ce Issued: 07/25/2008 Job Location: 2718 PLACID AVE Permit Type: Roof Job Description: BUILDING PERMIT Page 1 Conf #: 791 Permit #: SLC- 0807-0230 City: FORT PIERCE FEAR OFF(REROOF 3 PLY CERTAINTEED BUR W/ TAR & GRAVEL 1000.00 SQ FLAT - 800 SF -2/12P - FOR SINGLE =AMILY RESIDENCE S/D Corso Courts Lot: 22 Block: Parcel: 2421-606-0022-000/9 Contractor MOSLEY ROGER A R & M ROOFING CO INC (772) 464-8419 529 S MARKET AVE FORT PIERCE, FL 34982 Property Owner WILLIAM L WOLF (TR) (772) 461-3108 2718 PLACID AVENUE FORT PIERCE, FL 34982 Setbacks Left: Right: Front: Rear: Zoning: RS-4 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: Flood Zone: Elev: Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. T Treasure Coast Building Engineers; xitc. C Harvey Koehnen, P.E. - B 7205 Elyse Circle E Port St. Lucie, FL 34952-8212 Inc. Phone: (772) 466-5509 FAX: (772) 489-3035 91 July 24, 2008 To: St. Lucie County Building Dept Re: Permit 40807-0230 Roof at 2718 Placid Ave. 130mph/Exp B To Whom It May Concern: With reference to the above, follow NOA 08-0227.07 (copy attached). Manufacturers uplift allowed =-60psf, required = -51.0 corner zone. This meets 2004 FBC with 2006 amendments. If you have any questions, I can be reached at 772-466-5509. Very truly yours, Harvey K6oe , en, P.E. 32831 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY SS NECESSARY IN ORDER TO - 9QMY WITH " APPWQAPW 09m, hkoehnen@tcbeweb.com CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBU1Y OF THE CONTRACTOR OF RECORD BUILDING REYI DATE d • 2 . PLAN AND PERMIT MUST` KEPT ON JOB OR NO INSPECTION WILD. BE MADE www.tebew6b.com M ( A M I-DADE: BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION FILE COPY MIAMI-DADE COUNTY, FLORIDA METRO-DADE FTAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 'MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX-(305) 375-2908 NOTICE OF ACCEPTANCE (NOA) CertainTeed Corporation (PA) 1400 Union Meeting Road, P.O. Box I100 Blue Bell, PA 19422 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the .accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Conventional Built -Up -Roof Systems Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name -or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after. the expiration- date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate -this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 03-0827.05 and consists of pages I thr ugh 21. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 08-0227.07 Expiration Date: 06/19/13 rtv�rt► aaae COUNTYExpiration Date: 05/15/08 Page 1 of 21 ROOFING ASSEMBLY APPROVAL F, COPY Category: Roofing Sub -Category: Built -Up Roofing Material: Fiberglass Deck IyM Wood Maximum Design Pressure -60 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description All Weather/Empire Base 36" x 72; Roll ASTM D 2626 Asphalt coated, organic base sheet. Sheet weight: 86 lbs. UL Type 15 (2 squares) Flintglas® Mineral 36" X 36; Roll ASTM D 3909 Asphalt impregnated and coated Surfaced Cap Sheet Weight: 78 lbs. inorganic glass fiber surfaced with . (1 square) mineral granules used as the top ply in conventional built-up roof membranes. Flintglas® PIy Sheet Type 36" x 180; Roll ASTM D 2178 Fiberglass, asphalt impregnated ply sheet. IV or VI weight: 40/55 lbs. Type IV or VI (5 squares) UL Type G1 Flex-I-Glas or FIex-I-Glas 36" x 108; Roll ASTM D 5147 SBS Modified, fiberglass reinforced base FR Base Sheet weight: 901bs. sheet. (3 squares) 1 G1asBase-rm Base Sheet 36" x 108'; Roll ASTM D 4601 Asphalt coated, fiberglass base sheet. weight: 69 lbs. UL Type G2 • (3 squares) No. '15 Perforated Felt 36" _x 144', Roll ASTM D 226 Organic asphalt saturated felt. weight: 90 lbs. (4 square) Yosemite® Mineral 36" x 36; Roll ASTM D 249 Mineral Surfaced organic cap and buffer Surfaced Cap Sheet weight: 901bs. UL Type 30 . sheet. NOA No.: 08-0227.07 MIAMbDADE COUNTY Expiration Date: 06/19/13 • Approval Date: 05/15/08 Page 2 of 21 1 COPY APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) F1intBoard ISO Polyisocyanurate foam insulation CertainTeed PYROX Polyisocyanurate foam insulation Apache Products Co. ACFoam II Polyisocyanurate foam insulation Atlas Energy Products ISO 95+ Polyisocyanurate foam insulation Firestone Building Products, Inc. High Density Wood Fiberboard Wood fiber insulation board generic Perlite Insulation Perlite insulation board generic Dens Deck Water resistant gypsum board G-P Gypsum Corp. ENRGY-1, ENRGY-2, Plus, Polyisocyanurate foam insulation Johns Manville UltraGard Gold, PSI-25 FiberGlass Roof Insulation Glass fiber/Mineral fiber insulation Johns Manville Fesco Board Expanded mineral fiber insulation Johns Manville ISORoc Polyisocyanurate foam / rckwool Johns Manville composite insulation Paroc Cap Board Rockwool insulation Partek,, Inc. Multi -Max, FA Polyisocyanurate foam insulation- RMax, Inc. APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. #12 & #14 Dekfast Insulation fastener Construction Fasteners, Inc. Fastener 2. Dekfast Hex Plate Galvalume AZ50 steel plate 2'/8" x 3 V4" Construction Fasteners, Inc. 3. -Dekfast Lock Plate Polypropylene plate 3" x 3 I/4" Construction Fasteners, Inc. 4. #12 & #14 Roofgrip Insulation fastener for wood ITW Buildex Corp. Fasteners and steel. 5. A,ccuTrac Hextra Insulation fastener for wood ITW Buildex Corp. Fasteners and steel ` 6. Metal Plate Galvalume stress plate. 3" round ITW Buildex Corp. 3" square NOA No.: 08-0227.07 MIAMICADEcourvrr Expiration Date: 06/19/13 • • • Approval Date: 05/15/08 Page 3 of 21 APPROVED FASTENERS: copy TABLE 3 Fastener Product Product Manufacturer. Number Name Description Dimensions (With Current NOA) 7. Gearlok Plastic Plate Polypropylene round plate 3.2" ITW Buildex Corp. 8. UltraFast Insulation fastener for wood Johns Manville and steel. 9. UltraFast ASAP Pre -assembled Insulation Johns Manville fastener and plate 10. UltraFast Metal Plate Galvalume AZ55 steel plate 3" square & Johns Manville 3" round 11. UltraFast Plastic Plate High Density Polyolefin 3" round Johns Manville round plate 12. Olympic Fastener #12 & Insulation fastener Olympic Mfg. Group, Inc. #14 13. Olympic Standard Ga.lvaIume AZ50 steel plate 3" round Olympic Mfg. Group, Inc. 14. Insul-Fixx Fastener Insulation fastener for steel SFS Stadler, Inc. andwood decks 15. Insul-Fixx S Plate Galvalume AZ50 steel plate 3" round SFS Stadler, Inc. 16. Tru-Fast Fasteners Insulation fastener for wood The Tru-Fast Corp. and steel decks 17. Tru-Fast MP-3 Galvalume AZ50 steel plate 3" round The Tru-Fast Corp. 18. Tru-Fast Plates Galvalume AZ55 steel .plate 3" round The Tru-Fast Corp. 19. Tru-Fast Plates Polyethylene plastic plate 3" round The Tru-Fast Corp. EVIDENCE SUBMITTED: Test Agency/Identifier Name Repo Date Factory Mutual Research Corp. Fastening Requirements FMRC 1996 01/01/96 FMRC 4470 J.I. #3Y8AI.AM 03/23/96 Exterior Research & Design, Inc. TAS 114 3513.08.02 08/15/02 TAS 117 3515.07.03 07/22/03 NOA No.: 08-0227.07 MIAMH•DADE ffi NW Expiration Date: 06/19/13 • •. Approval Date: 05/15/08 Page 4'of 21 COPYDeck Type 1: Wood, Non -Insulated Deck -Description: 19/32" or greater plywood or wood plank attaohed using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o: C. 1 System Type E(3): Base sheet mechanically attached. Base Sheet: GlasBase base sheet or Flintglas Premium Ply Sheet mechanically attached as detailed below. Fastening: - Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps.8"o.c. in the lap and three rows staggered in -the center of the sheet 8"o.c. Ply Sheet: Two or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) or #15 Asphalt Perforated Felt ply sheet adhered in a full mopping of approved asphalt at an application rate of 20-40 lbs./sq. Cap Sheet: (Optional) One ply -of Flintglas Mineral Surface cap sheet adhered in a full mopping of approved asphalt at an application rate of 20-40 lbs./sq. Surfacing: (Required if no cap sheet is used) Install one of -the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. A two part coating consisting of a base coat of Static Asphalt Fibered Emulsion at rate of 3 gal./sq. or Monoform compound; surfaced with 1 gal./sq. Sta-Kool non-fibered aluminum coating or fibered APOC No. 212. Maximum Design Pressure: -60 psf (See General Limitation 47) NOA No.: 08-0227.07 Expiration Date: 06/19/13 Approval Date: 05715/08 Page 20 of 21 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. 2. 3. 5. Q 7. 8. a Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer Alf standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf, Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf insulation attachment shall not be acceptable. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the -fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements. of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117.'Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) MIAMI•DADE COUNTY ..81 END OF THIS ACCEPTANCE NOA No.: 08-0227.07 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 21 of 21