Loading...
HomeMy WebLinkAboutSUBMITTED PAPERS1J RECEIPT #: - PERMIT #: - -- - -- - --- 1 St. Lucie County oC"- � 15� Building & Zoning Department SCAMFL ,CC Y 8 2300 Virginia Avenue Y - - - -- -- -- Fort Pierce, FL 34982 772-462-1553 uCle Cr)llr,tl, APPLICATION FOR STORM SHUTTER PERMIT SEE REVERSE SIDE FOR INSTRUCTIONS 1. LOCATION/SITE ADDRESS: `�O C) a \ "e' 2. PARCEL IDNUMBER: �` I l'� `,L' `p0—j �p Q00 3 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: 4. TYPE OF STRUCTURE: SFR 5. OWNERS INFORMATION Name: Q �1 j �1 �2y) Address: City: "����� State: G� Phone: Zip: ��q �— �. :est.a OTHER 6. CONTRACTORS INFORMATION FL REG/CERT #: ftz-b�D COUNTY CERT #: -1 Business Name: sen' -1 Type of Surface attachment: Wood Frame Concrete Masonry Other Product Minimum Design Pressure Product Compliance Report # Method of Attachment As per 1707.4.4.1 FBC Type 120 mph 130 mph 140 mph 140 Exp. C SBCCI Dade Other Anchor Type Anchor Spacing Impact Glazing Removable Panels Accordion E.. fk Iz! Roll Up Colonials Other ALL PRODUCTS SHALL BE LABLED SBCCI OR DADE COUNTY FOR DETERMINING IMPACT RESISTANCE FROM WIND BORNE DEBRIS. **SEE FINAL INSPECTION PROCEDURE FOR EXISTING RESIDENTIAL STRUCTURES ON BACK. 7. VALUE OF CONSTRUCTION: $ OWNER'S AFFIDAVIT: I certify that all of the information contained in this application i rrect an a work ill be done in compliance with all applicable laws regulating construction m PRINT ALIFIERS/OWN S NAME SIG TURF OF STATE OF FLORIDA, COUNTY OF ACKNOWLEDGED BEFORE ME THIS _DAY OF20_, WHO I SONALLY KNOW TO ME , OR WHO HAS PRODUCED _ AS IDENTIFICATIO SIGNATURE OF NOTARY TYPE OR PRINT NAME OF NOTARY *NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. CHRISTINA BROft Notary Public, State of Florida My Comm. Expires Feb .17, 2009 No. DD397778 INSTRUCTIONS Please complete all information in the spaces provided. All information must be Printed (use black or blue ink only) or Typed. This application for Shutters to be used for only those activities that is not otherwise included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition to the installation of Shutters, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. LOCATION/SITE ADDRESS: .............................................. Indicate the street address, or general location, of the property on which the building activity is taking place. 2. PARCEL ID NUMBER: ........................................................ Indicate the Property Tax Identification Number for the property on which the building activity is taking place. 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY........ Briefly describe the building activity under permit application. 4. OWNERS INFORMATION: ................................................. Indicate the name and address of the owner of the property on which the product is to be installed. 5. CONTRACTORS INFORMATION: .................................... 6. VALUE OF CONSTRUCTION: .......................................... Indicate the State of Florida (if applicable) and St. Lucie County contractor's registration numbers, and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. The value of construction is used to determine the amount of permitting fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. All applications for the installation of Shutters are to be submitted to the St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through. Friday. Following the issuance of this Shutter Permit, the scheduling of all required inspections may be made by calling (772) 462-1261. INSPECTIONS ** EXISTING RESIDENCES: All shutters must be installed and in place at the time of the final inspection, except for Egress Windows and Doors where one panel must be installed and the remainder must be by the opening for the inspector to verify remaining panels. ** NEW HOMES: All shutter panels must be installed at time of final inspection or inspection will fail and C.O. will not be issued. SLCCDV FORM NO: 006-05 09/18/2008 09:28 FAX 7724661074 SOUTH FLA ALUMINUM -s 1@002 EDWIN M, FRY, Jr.r�r tK 05' THE CIRCUIT COURT — SATNT Lt)rlE IPY (` FILE # 3233013 OR a... .?99H PAGE 1708, Reeozded 07/16/2008 at 03:37 PM AI_rt'N Nl:mgmNe.recnn<N iQ; 1:VW ,&?0hr•.k OTICC OF COMMENCEWNIT The unctrsiguo hereoy gh rA notim that inwrovomont will be made lu certain mal properly, Bud In accordance will, Clthhter 713. I'lorida sratotes the fallowir g inform jinn is provided in •Le Notice of amull 9ement. 1,lips v1iONl(IFPROPERTY (Lxgoldescriptionand sVcctaddrew)TAX FOLIO NUMBER- �L�� M {.I!'`- UIL7SI0 ? _✓_� Et K TRACT U7 DG w 2, ENSKALD CRl T OF PKUYEM P= 10 WNER ifVFU ATIU a. Name b. AJdroat:O V+' IL` %(1 t _ _ ± L c, ipu is pm y 4 d, Ngme and addrers of tc simp tillcholdef (if or tha owocr) 4. NTRAGTO$R�Nhth tD 55ANDP ONE "E - fj, �,,t� rh ? Jciu<. irv-- 6. LENDER'S NAME, AE• DRts5 AND PHONE NUMBER: 7. Pasoas within the SIYle tW Ploridn deAgnaluf by Owner upon whom notices or other doeumentt ntay be sewed as provided by Soctiod 713.11(1 Xa) L Aoridn Statutes: NAME. A13130448 AND f 1I0NE NUMBER: 9. In addition to himu if cr hr aelf. Owner designates the fullowing In rrptive a ropy of the Lienor s Notice no provided in Section 713,13 (1)(b), Dori& SIPntleG NAME, APIOMS AND I siONX NUMUER: 9. Expiration dutc of riodet of commencement (the expiration date is 1 year from the dare of recording unless a difftmnt date is trvame of personl t•YY'v, u�wvuq...o,�, vwarv,. v ... .., a .. i For ��-• � }^ _ (Name of patty on beba6 of Whom insttu rjmd wos exocutul) Pusunally K,lowa_ nr produced the following type of ID: 1 CHRKMA amwN Notary Public, stale of Flbtldn Wyt;omm, ExdraO Feb.17.1ffb6 1 7wl^. _rti lJna..• No. D0,197rm (printed Name of NotaryPullie) (SignoturoofNotaryPublic) Under penalties of perjury. I declare that I have crud the foregoing and that the facts in it urc true to the best of my knowledge and boiicf (scclibn 92.525. F,lprida Statutes). .VEI l7c/ D SEP 18 2008 Public Works St. .Lucie CountyFL Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 hftp://stiucieco.gov/ce Issued: 07/14/2008 Job Location: 5800 SILVER OAK DR Permit Type: Storm Shutter Job Description: BUILDING PERMIT Conf A 611 Permit #: SLC- 0807-0247 City: FORT PIERCE INSTALLATION OF HURRICANE SHUTTERS FOR 4 OPENINGS FOR SINGLE FAMILY RESIDENCE Page 1 S/D Indian River Estates Unit 6 Lot: 13 Block: 21 Parcel: 3402-607-0216-000/3 Contractor WHIGHAM GARY K SOUTH FLORIDA ALUMINUM PRODU, (772) 466-0913 4801 S US 1 FT PIERCE, FL 34982 Property Owner DAVID A WILES ( ) - 5800 SILVER OAK DRIVE FORT PIERCE, FL 34982-3223 Property Owner CAROL D FRIDOLPH 5800 SILVER OAK DRIVE FORT PIERCE, FL 34982 Setbacks Left: Right: Front: Rear: Zoning: RS-3 Number of Units: 1.00 Floors: 1 Buildings: 1 Square Footage: 0.00 Minimum Floor Elevation: Flood Map: 281G Flood Zone: AH Elev: 17 Permit holder acknowledges through acceptance of this permit that separate permits must be obtained as required by the Florida Building Code including those for all electric, plumbing, mechanical, roofing, and structural work. Further, he/she acknowledges responsibility to comply with all requirements of the 2004 Florida Building Code. NOTICE: In addition to the requirements in this permit, there may be additional restrictions applicable to this property that may be found in the records of this County, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. s:553.79(10), F.S. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BUILDING IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. s.713.135, F.S. Christopher Lestrange Building Official Date For Automated Inspections, Call (772) 462-1261 For Questions, Call (772) 462-2172 St. Lucie County Land Development Code Section 11.05.01 (A) (2) states; Building Permits shall expire and become null and void if work authorized by such Building Permit is not commenced, having called for and received a satisfactory inspection, within six (6) months from the date of issuance of the permit, or if the work is not completed within 18 months (permit by contractor) or 24 months (permit by owner) from the date of issuance of the Building Permit. o - per^ / E DESIGN 'PRESSURE CALCULATION for Exposure B, Wind speed 140 mph and Mean roof height 15 ft Contractor: Preparer: South Florida Aluminum ProductGary Whigham Project Address: 5800 Silver Oak Ft pierce FI 34982 # Width Height Locations+ 135 86 Interior 3Q 62 33 62 i 2 125 86 Interior 30 81 33 $1 e 3 127 86 Interior 30 77 33 77 „ 4 132 86 Interior.a- VIA ulalauuaS vv�av vaaaauv i i ict Approval Public User M y 6 Submit Surcharge! Stats & Facts' Publicationsl FBC Staffl BCIS Site Mapi Links! Searchl Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL10753 Application Type New Code Version 2007 Application Status Pending FBC Approval Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Town and Country Industries_, 400 West McNab Road Ft. Lauderdale, FL 33309 (954)493-8551 tomj@tc-alum.com Tom Johnston tomj@tc-alum.com Thomas B. Johnston 400 west McNab Rd. Ft. Lauderdale, FL 33309 (954)070-9999 tomj@tc-alum.com Shutters Accordion Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Vladimir John Knezevich developed the Evaluation Report Florida License PE-10983 Quality Assurance Entity National Accreditation & Management Institute, Quality Assurance Contract Expiration Date 12/31/2009 Validated By ORLANDO L. BLANCO, P.E. Validation Checklist -Hardcopy Received Certificate of Independence FL10753 RO COI 2008 Certificate of Independence-FBC-signed.pe Referenced Standard and Year (of Standard) Standard Year ASTM E1886 2005 ASTM E1996 2005 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 of 2 6/7/2008 11:17 AM DnOS Duilumg t-oue urume i C,� Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Of Method 1 Option D 05/19/2008 05/19/2008 05/22/2008 FL # Model, Number or Name Description 10753.1 6.8 Accordion Bi folding aluminum accordion shutter Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL10753 RO II 08225 Drawing-pdf Approved for use outside HVHZ: Yes Verified By: Vladimir John Knezevich 10983 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See tables 1 and 3 on page 1 of 11 for design FL10753 RO AE 68 HVHZ Report 08-225.pdf pressure vs span Created by Independent Third Party: Yes Bach ,Nextl DCA Administration Department of Community Affairs Florida Building. Code Online - 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000-2005 The State of Florida. All rights. reserved. Copyright and Disclaimer Product Approval Accepts: 9' ego•. of 2 . 6/7/2008 11:17 AN KNEZEVICH ASSOCIATES CONSULTING ENGINEERS no 2590 SW 105 Terrace Davie, Florida 33324 ' Vi1v 821.6933 • (954) 452.7960 —fax KA Job No.: 08-225 Date: May 15, 2008 FBC Evaluation Report No.: FL10753 Code: Florida Building Code, 2007 Product Category: Product Sub -Category: Product Name: Manufacturer: Shutters Accordion 6.8 Accordion Shutter Town and Country Industries 400 West McNab Road Fort Lauderdale, FL 33309 EVALUATION REPORT This is an Evaluation Report issued by Knezevich Associates (System ID No. 1801), V:. John Knezevich, P.E. to Town and Country Industries, based on Rule Chapter No. 9B-72.070, Method 1(d) Product Approval, Florida Building Commission, and Department of Community Affairs. This Accordion Shutter has been evaluated. and found to be in compliance with the Code and that the product is, for the purpose intended, at least equivalent to that required by the Code. Re-evaluation of this Evaluation Report is required, following any code changes, to maintain its validity. '2. SUBSTANTIATING DATA 2.1 PRODUCT EVALUATION DOCUMENT ■ Town and Country Industries 6.8 Accordion Shutter, Drawing No. 08-225, with no revision, dated May 15, 2008; Sheets 1 through I ; prepared by Knezevich Associates, signed, dated and sealed by V. John Knezevich, P:E. is an integral part of this Evaluation Report.. 1i3 '•'bft:�la'repar by: T?lotfda��AAI�o�,�7�89. Page 1 of 3 KNEZEVICH ASSOCIATES CONSULTING ENGINEERS 2590 SW 105 Terrace EVALUATION Davie, Florida 33324 REPORT (954) 821.6933 • (954) 452.7960 —fax 2.2 TEST REPORTS ■ Test report for Uniform Static Air Pressure in accordance with PA 202, and meets ASTM E330-90. Test report for Large Missile Impact and Cyclic Testing in accordance with PA 201 and PA 203. Reports prepared by Construction Testing Corporation (CTC), Report No. 98-050 dated October 31, 1998, CTC Report No. 00-013 dated June 3, 2000, CTC Report No. 02-033A dated July 11, 2003 and CTC Report No. 03-024 dated October 1 % 2003, all signed by George Dotzler. Additional TAS 201-94, TAS 202-94 & TAS 203-94 as well as ASTM E330-02 and ASTM E 1886-05 & E 1996-05 testing was performed at Hurricane Test Laboratory, LLC, Report No. 0353-1102-07 dated April 4, 2008, signed by Vinu J. Abraham, P.E. ■ Tensile Capacity of aluminum alloy extrusions was determined in accordance with ASTM E8/A370, in report No. 0944H prepared by Certified Testing Laboratories on September 17, 2002. 2.3 STRUCTURAL ENGINEERING CALCULATIONS Prepared Rational and Comparative Analyses of Accordion Shutter performance, as well as anchor calculations. From these analyses, High Velocity Hurricane Zone (HVHZ) and Non- HVHZ, Maximum Shutter Span vs. Design Load (PSF) Schedules were prepared for the 6.8 Accordion. An anchor spacing vs. design load (PSF) schedule was also prepared, indicating of anchor used during testing, for both accordions. For the HVHZ, a Separation from Glass Schedule (Schedule 2) was prepared. For the Non-HVHZ, no separation from glass is required, but a Separation from Glass Schedule (Schedule 4) was prepared for use only with ASTM Wind Zone 4 requirements. - A 33% increase in allowable stress has not been used in the design of this product. l ilia l VVV1---,.........,.....,......,_»_.�___� r------ - -- - - - the PA 201-94, TAS 201-94 and ASTM E 18-86-05 and E' 1996-05. This Accordion -Shutter system may be used to protect glazed openings from windborne debris in High Velocity Hurricane Zones, when installed in accordance with the limitations indicated in Drawing No. 08-225, prepared by:Knezewch Associates. This Aceord�ori Shutter'systern has Been designed to resist wind .pressures as Indicatea ny the Span Schedules, Table 1 & Table 3, page 1 of 11 for the 6.8 Accordion Shutter Drawing No. 08- 225. Page 2of3 KNEZEVICH ASSOCIATES CONSULTING ENGINEERS 2590 SW 105 Terrace EVALUA'nON Davie, Florida 33324 (954) 821.6933 • (954) 452.7960 — fax REPORT ANCHORS5. The maximum anchor spacing for each type of anchor, shutter.span & design wind load is found in the Anchor Schedules on pages 10 & 11 of 11 of the 6.8 Accordion Shutter Drawing No. 08- 225. This Accordion Shutter system is to be installed in accordance with the typical details, general notes, schedules and material specifications found in Drawing No. 08-225. See General Notes # 13 and #14 on page 2 of 11, of Drawing No. 08-225. All dimensions" of components 1 through 40c are indicated on pages 3 & 4 of 11, Drawing No. 08-225. Anchor specifications including acceptable substrate, minimum embedment, edge distance and manufacturer are indicated on pages 10 & 11 of 11 for the 6.8 Accordion Shutter, Drawing No. 08-225. ■ Use of this productshall be in strict. conformance with the requirements of Drawing No. 08- 225 prepared by Knezevich Associates and signed, dated and sealed by V. John Knezevich, PE. well as the Non HVHZ. ■ This product may only be installed on concrete, hollow concrete block or wood substrates. For all other conditions site specific design shall be by this office or our delegated engineer. ■ This product.must be installed in accordance with the Minimum Shutter Separation From Glass Tables 2 & 4, page 1 of 11 for the 6.8 Accordion Shutter, Drawing No. 08-225 when used in the HVHZ or in ASTM wind zone 4. Page 3 of 3 T A e L I1 1 HVHZ MANDATORY COMPLIANCE ACCORDION SHUTTER SPAN SCHEDULE ASCE7 DESIGN WIND LOAD HVH2 POSITIVE WIND LOAD WITH UNIMATE ® HVHZ POSITIVE WIND LOAD WITH u zo & or Jt & J2 Of JJ & J4 HVHZ NEGATIVE WIND LOAD ALL MOUNTING CONDITIONS W (P.S.F.) . . d L max. (FT • IN) L max. (FT • IN) L mex, (FT • IN) 1 1 -0 1 -0 12- 13.0 13-0 30.0 12.4 12.11 13.0 35.0 11.10 12.6 13.0 40.0 11•5 12.1 13.0 45.0 11.1 I1.8 0'%o SO.0 10-10 11-5 Ik 54.3 10.7 11.2 13-0 55.0 10.7 11.1 12.11 60.0 10.4 10.11 12.4 65.0 10.2 10.8 11.30 7 ..0 9.11 10.6 11.5 75.0 9.9 10-3 11.0 80.0 9.7 10.1 10.8 85.0 9.6 10.0 10.4 90.0 94 9-10 IOA 95.0 9.3 9.8 9-10 100.0 9.1 9.7 9.7 105.0 9.0 94 94 110.0 8.11 9-1 9.1 115.0 8.9 8-11 8-11 120.0 8.8 8.9 6.9 125.0 B-6 130.0 -148AI B4 8-3 7-11 - 7.8 - 7.5 7-2 6-11 J155.0 - - - 6.9 - 6.6 64 6.2 185.0 - 6.0 90.0 - 5-10 195.0 - - 5.8 200.0 5.6 A HVHZ E MANDATORY COMPLIANCE 2 MINIMUM SHUTTER SEPARATION FROM GLASS POSITIVE DESIGN LOAD ACTUAL SHUTTER SPAN MIN, SEPARATION FROM GLASS FOR INSTALLATIONS 5 30'-0" ABOVE GRADE MIN.SEPARATION FROM GLASS FOR INSTALLATIONS > 30'•0" ABOVE GRADE (W) (P.S.P.) (I) 07-IN) (IN.) UN.) .. 293 13.0 3.3/4 3.3/8 30.0 5.0 3 1 8.3 2.1/4 1.318 1" 2.1/4 L-3/4 12-11 3-3/4 3.1/2 5010 5.0 3 1.1/8 8.3 2.1/4 1.5/8 9.0 2.1/4 2 11.5 3.3/4 3.1/2 70.0 S-0 3 1.1/8 7.0 3 1.1/2 8.3 2-1/4 1.3/4 10.6 3.3/4 3.1/2 9010 5-0 3 1.1/8 7.0 3 1.5/8 B-3 2.1/4 2.1/4 ' 9.10 3.1/2 3.1/2 110.0 S-0 3 1.1/4 6.0 3 1.318 8.3 2.1/2 9.1 3.1/4 3.1/4 12010 S-0 3 -1/4 7.0 3 1�3/ . 8-3 2.5/B •SIB 8.9 3 HVHZ-(TABLES 1 & 2 ONLY) TABLE NOTES; I.HVHZ: HZ: DEFINED AS MIAMI-DADE COUNTY AND BROWARD COUNTY FLORIDA, 2. WIND LOADS; DETERMINE POSITIVE AND NEGATIVE WIND LOAD FROM ASCE 7. 3.M IN TABLE 1, ENTER POSITIVE AND NEGATIVE WIND LOADS AND. READ ACROSS TO THE APPROPRIATE COLUMN TO DETERMINE MAX. SHUTTER SPAN (BLADE LENGTH). 4.REVERSING; THE 6,0 SYSTEM MAY BE MOUNTED WITH THE INSIDE AND OUTSIDE OF THE SHUTTER BEING REVERSED. FOR EXAMPLE: IT IS PERMISSIBLE TO MOUNT ON THE INSIDE OF A WOOD OR CONCRETE BEAM WITH THE BACK OF THE SLAT FACING OUTWARD. FOR THIS CONDITION YOU MUST ENSURE THAT THE SPANS IN THE APPROPRIATE POSITIVE.COLUMN OF TABLE 1 ARE APPLIED IN THE DIRECTION TOWARDS THE HOST STRUCTURE AND THE SPANS IN THE NEGATIVE COLUMN OF TABLE I ARE APPLIED IN THE DIRECTION AWAY FROM THE HOST STRUCTURE S. EP TO GLASS: DETERMINE SEPARATION FROM GLASS VALUE IN TABLE 2 WITH TH APPROPRIATE POSITIVE LOAD AND SHUTTER SPAN. 6.FOR DESIGN WIND LOADS BETWEEN TABULATED VALUES, USE LINEAR INTERPOLATION TO DETERMINE SPANS AND SEPARATION FROM GLASS, EXCEPT FOR LESS THAN 30 FT. WHERE INTERPOLATION IS NOT ALLOWED AND THE NEXT HIGHER LOAD MUST BE USED. IT NON-HVHZ & E ASTM Wind Zone 4 3 ACCORDION SHUTTER SPAN SCHEDULE ASCE 7 POSITIVE R DESIGN NEGATIVE WIND WIND LOAD ALL LOAD MOUNTING CONDITIONS W L.- R � 125.0 8.6 130.0 84 135.0 8-3 141,11 7.11 145.0 7-8 150.0 7.5 155.0 7-2 160.0 6.11 165.0 6.9 170.0 6.6 175.0 6.4 180,0 6.2 185.0 6.0 A NON. HVHZ ASTM s E Wind. Zone 4 - ONLY 4 MINIMUM SHUTTE0. SEPARATION FROM GLASS POSITIVE DESIGN LOAD SEPARATION LASS FOR LLATIONS 30'-0° E GRADE MIN, SEPARATION FROM GLASS FOR INSTALLATIONS > 30'-T ABOVE GRADE (W) (P.S.P.) JAMIN. N.) (IN.) 330.0 2.1 4 •3 B 10.0 2.14 .3 4 13.0 3,314 .1 40.0 5• 3 -1 B 8.3 2.14 .12 12-518 9.0 2•14 .3 4 10.0 2.14 -18 11.0 3.3 M1 13.0 4.1 4 4.1 4 5010 5.0 3 1.1 8 B-3 2.1 4 1.5 8 9-0 2.14 2 10.0 2-3/8 2.3 8 11.0 1 3.3/4 3-I8 13-0 S-1 8 S•1 8 60.0 5.0 3 1.1/8 8.3 2.1 4 1.3 4 9.0 2-1/4 2.118 10.0 2-3/4 2-3/4 12.4 5 5 70,0 5.0 3 1.1/6 7.0 2.1/4 1.1/2 8.3 2.1/4 1.3/4 11.5 4.1/2. 4.1/2 9010 5.0 3 1.1/8 7-0 2.1/4 1.5/8 8.3 2.1/4 2.1/4 10.1 3.3/4 3.5/8 11D.0 5.0 3 1.1/4 7.0 2.1/4 1.3/4 B•3 2.2/2. 2.1/2 9.1 3.1/4 3.1/4 120.0 5.0 3 1.1/4 71 P 1/14 1.3/4 8.3 23/8 2.5/8 8.9 3 3 rnpp4�U �FUGOG I I I 4.REVEggNG; THE 6.8 SYSTEM MAY BE MOUNTED WITH THE INSIDCA111 r �' die - i OUTSIDE OF THE SHUTTER BEING: REVERSED, FOR EXAMPLEL:Ifz RS PERMISSIBLE TO MOUNT ON THE INSIDE OF A WOOD OR CONCRETE %•" •� Td NON-HVHZ & ASTM, WIND ZONE 4 WITH THE BACK OP THE SLAT FAC)NG:OUTWARD, FORTHIS CONOGI III ASTM WIND ZONE 4, USE THE APPROPRIATE POSITIVE LOAD/NAQ V1 N - - ABLES 3"& 4 ONLY)TABLE NOTES( LOAD AND SHUTTER SPANS IN THE APPROPRIATE POSITIVE COLfJM P TABLE 4. % �: _ S, SEPARATION TO GLASS: (TABLE 2 or 4) 15 NOT REQUIRED 1N WINO 2SN 1. NON-HVHZ; DEFINED AS ALL LOCATIONS OTHER THAN MIAMI•DADE THRU3(140 MPH WINDSPEID AR LF55), SEPARATIONFROM'GLASSA7 iEL COUNTY NWT: AND BROWARD COUNTY FLORIDA. . q IS REQUIRED FOR:WIND ZONE 4 (141 MPH'OR GREATER WIND SPE , 5 �aaM 09%49� 2. ASa 7• DETERMINE POSITIVE AND NEGATIVE WIND LOADS FROM j ENTER TABLE 4 WITH THE DESIGN POSITIVE.LOAD AND READ. ACROSS Q THE SEPARATION FROM GLASS VALUE IN COLUMNS 1 OR 2 (WHICHEVER:IS+� 3.5PAN; IN #('ABLE 3, ENTER NEGATIVE WIND LOAD ONLY, DETERMINED APPROPRIATE). i ' �•e8��d�5'-'-" FROM ASPS 7, THEN MOVE ACROSS TO SELECT THE ALLOWABLE - 6,FOR DESIGN WIND LOADS BETWEEN TABULATED VALUES, USE THE NEXT - SHUTTER fi PAN (BLADE LENGTH). SHIGHER HUTTER SPAN. OR USE LINEAR INTERPOLATION TO DETERMINE ALLOWABLE PAGE i of 11 GENERAL NOTES; 1. THESE EVALUATION DOCUMENTS REPRESENT A SHUTTER SYSTEM ANALYZED WITH THE PROVISION SET FOR THE ISSUANCE OF A FLORIDA BUILDING CODE PRODUCT APPROVAL, FOR THE HIGH VELOCITY HURRICANE ZONE (HVHZ) & NON -HIGH VELOCITY HURRICANE ZONE (NON-HVHZ). 2. THIS SYSTEM HAS BEEN TESTED AND EVALUATED AND IS IN COMPLIANCE WITH THE INTERNATIONAL BUILDING CODE (IBC) AND THE INTERNATIONAL RESIDENTIAL CODE (IRC). 3. NO INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THESE PRODUCTS, WIND LOAD DURATION FACTOR Cd - 1.6 WAS USED FOR WOOD LAG SCREW DESIGN. 4. THIS SYSTEM HAS BEEN TESTED AND EVALUATED AND IS IN COMPLIANCE WITH THE FLORIDA BUILDING CODE (FBC) REQUIREMENTS, INCLUDING THE HIGH YELOCTTY IURRICANE ZONE (HVHZ). THIS SYSTEM r ,` MISSILE LEVEL "D" AND INCLUDES WIND ZONE 4 AS DEFINED IN ASTM E3996.05. 5.? �iG WAS CONDUCTED IN ACCORDANCE WITH TAS 201/202/203 AND ASTM E1886.05/E1996.05/E330.02. 6.'=_. _IMINE THE POSITIVE AND NEGATIVE DESIGN LOADS TO USE WHEN REFERENCING THESE DOCUMENTS IN ACCORDANCE WITH THE GOVERNING CODE AND GOVERNING WIND VELOCITY. FOR WIND LOAD CALCULATIONS IN ACCORDANCE WITH ASCE 7, A DIRECTIONALITY FACTOR OF Kd -0.85 SHALL BE USED. 7. THESE APPROVAL DOCUMENTS ARE GENERIC AND DO NOT INCLUDE INFORMATION FOR SITE -SPECIFIC APPLICATION OF THIS SHUTTER SYSTEM. B. USE OF THESE APPROVAL DOCUMENTS SHALL COMPLY WITH CHAPTER 61GIS-23 OF THE FLORIDA ADMINISTRATIVE CODE. 9. THESE APPROVAL DOCUMENTS ARE SUITABLE TO BE APPLIED BY THE CONTRACTOR PROVIDED THE CONTRACTOR DOES NOT DEVIATE FROM THE CONDITIONS DETAILED HEREIN AND THE CONTRACTOR VERIFIES THAT THE EXISTING STRUCTURE DOES NOT DEVIATE IN EITHER FORM OR MATERIAL FROM THE STRUCTURAL SUBSTRATES DETAILED HEREIN. 10,ANY MODIFICATIONS OR ADDITIONS TO THESE APPROVAL DOCUMENTS WILL VOID THE APPROVAL DOCUMENTS, II.WHEN THE SITE CONDITIONS DEVIATE FROM THESE APPROVAL DOCUMENTS, THE BUILDING OFFICIAL MAY REQUIRE THAT SITE SPECIFIC DOCUMENTS BE PREPARED, SIGNED, DATED AND SEALED BY A LICENSED ENGINEER OR REGISTERED ARCHITECT, WHICH DETAIL AND 3USTIFY THE DEVIATION,. AS A CONDITION TO THE BUILDING OFFICIAL GRANTING HIS/HER APPROVAL 12. EACH SHUTTER ASSEMBLY SHALL BE PERMANENTLY LABELED WITH THE FOLLOWING MINIMUM INFORMATION: TOWN &COUNTRYIND. FORT LAUDERDALE, FL. MISSILE "D" • ASTM E1BB6, E1996 & E330 TAB 201,202 & 203 FLORIDA BUILDING CODE APPROVED l y 4(TRUSIONS SHOWN SHALL BE 6063-T6 ALUMINUM ALLOY, U.O.N., WITH A MINIMUM Fy OF 20 K.S.L I 'bLTS AND WASHERS (EXCLUDING INSTALLATION) SHALL BE STAINLESS STEEL WITH A MINIMUM -_. _'LE STRENGTH OF 60 K.S.I., U.O.N. POP RIVETS SHALL BE 1/4"0 OR 3/16"0 5052 ALUM. ALLOY. 15.ALL SHUTTERS SHALL HAVE A LOCKING MECHANISM CONSISTING OF THUMBSCREW, PUSH LOCK OR BOX LOCK AT CENTER OR SIDE CLOSURE. 16.TOP AND BOTTOM DETAILS MAY BE INTERCHANGED AS FIELD CONDITIONS REQUIRE. SEE PAGE 5 FOR LOCK LOCATIONS AND DETAILS. 17. FLOOR TRACKS MAY BE REMOVABLE AT NON -STACKING LOCATIONS. USE REMOVABLE ANCHORS, 18.THE ACCORDION SHUTTERS MAY BE MOUNTED WITH THE INSIDE AND OUTSIDE OF SHUTTER BEING REVERSED. FOR EXAMPLE; IT IS PERMISSIBLE TO MOUNT EXTRUSIONS ON INSIDE OF WOOD OR CONCRETE BEAM WITH BACK OF SHUTTER FACING OUTSIDE (SEE PAGE 5 - TYPICAL PLAN VIEW). 19. DETAIL 5 to 12, 16 & 27 an page 3 to 4, MAY BE BENT TO FORM A CURVE WITH A MIN. RADIUS OF 10". 20, ALL DIMENSIONS SHOWN INCLUDE POWDER COATING FINISH. SECTION TOP TRACK ro I w Q Pq ti PLAN w o VIEW rn wJ E F¢— w w rn P BOTTOM TRACK LOCKING MECHANISM, SEE TYPICAL PLAN VIEWS TYPICAL ACCORDION SHUTTER ELEVATION N.T.S. 4 R8 gg'�E y3� I �'trf�tS 2^�05/t9% PAGE 2 of 11 .068•' t 2.782" . aee 195 1 -.6 9 .t OB' ,630 1.250"°i 2.728 .09 1095' ,2.82 1.708 971" .030' 2 3.610" .372" 50 ..�.• y LITE 2=LEG WALL 51'g OHEAVY 2—LEG WALL O O HEAVY HEADER/SILL O LITE HEADER/SILL Wc� 3 SCALE: HALF 512E SCALE. HALF 512E N �t SCALE, HALF SIZE SCALE, HALF SIZE Q� YYIILI\L JIIV YYII .,I.L.. 430SSES &FELT GROVES ARE OPTIONAL ON ALL EXTRUSIONS o I- 2,655' 1.825' .875' , 95' 1.230' 2,19 5 510' I I N 1 , N N I.621. ,ns• c1 2.300" 4-250" T7�SILL 4.510" Og SILL ADAPTER SCALE: HALF SIZE SCALE: HALF 512E 3 " 30,0.2412355"0°R '35 297" I 06 0 ,r.030R .31446 0 1.625" .069" 13 TYP. 6.8 SLAT/BLADE 17 6.8 STARTER SCALE:. HALF SIZE SCALE: HALF SIZE ,130' 4 510" 3 4.102" .227" .054" 14 2.195' Og EXTENDED SILL SCALE, HALF SIZE BASE TRACK 14 CEILING HEADER/SILL 15 6.8 STACK/CONECTOR SLAT/BLADE SCALE: HALF SIZE SCALE: HALF SIZE II `9�1j 5`PY—1 ti I I N I ,105' i gN TYP I 1 I I I � l 10 EXTENDED SILL SCALE: HA SIZE 143' 13• 1,708 0 .682' 16 Rf sr :630' 0 2.655' 2.365' e m 510' 460' 085, n % I 060•� TOR 11 MID SILL SCALE: HALF SIZE 0.080' 0Z00801 t N 18 WALL SILL CLIP SCALE: HALF SIZE 0 4,510'--k 12 MID SILL ADAPTOR SCALE. HALF SIZE 570' .510' b N N 0,080' 0,117' N IIII #,060' m pO�Q 30• 18b WALL SILL SCALE, HALF SIY;(=,��� r, PAGE 3 of 11 q.125' 1 5' MAX. �g ANGLE SCALE. HALF SIZE O18' 010-24 THUMB 510, SCREW m L ,062' 8 ¢ 20 RECESS SILL FOR USE WITH SCALE, HALF SIZE ® AND ® ONLY 21 SLIDE ROD SCALE, HALF SIZE 1075" '1125" 0 WHERE LOCK PINS ARE USED, THEY ARE ENGAGED IN THE RE STACKED POSITION & AREN'T O'D IN THE CLOSED POSITION. 25 OPTIONAL ALUMINUM OR PVC LOCK PIN FOR 29A+29B SCALE. HALF SIZE �443' .443'.090' SS5501 o N 1.06B' 239' 3.443' .496' 1.75 C21 )3 6.8 CENTER MATE 3p UNIMATE LOCK _j1LE; HALF SIZE SCALE: HALF SIZE 5.500' x 13/16' WIDE t—f .400- A y N 166' TYP. 4.50 ' .I'--4,689' EE��TTqq LL 22pp22 � SECTION A PNDUSTRIALOESYSTEMS 35 BOX LOCK SCALE: HALF SIZE .357' '.276' ,062' N 154' :137' 2B BOX CENTER INSERT SCALE. HALF SIZE .236' 1.710' Pn II j .284 m 26, Cn A it lU .160' 1�0I' ,062' 31 MALE BOX CENTER SCALE: HALF SIZE POWDER COATED, ZINC DIE-CAST 36 T-LOCK ADAPTER (OPTIONAL) SCALE, HALF SIZE .050" WHEEL 1.100" .240" TYP. AT EVERY OTHER INSIDE JOINT AT TOP. 22 ROLLER ASSEMBL SCALE, HALF SIZE f-1,250' ��; I� 2.750' 27 RAINGUARD SCALE. HALF SIZE I .286' II r I �J � I11 C1 0� I I� J M 32 FEMALE BOX CE Cf AI F, HALF S1ZE 1.950" NYLON WASHER oPiNTO OR ALUMINUM ^'(NYLON BUSHING o w OPTIONAL) �AOZ p G t0N. u `! 0. Y °114 x 2-3/4" 410 HT S.S. CREW W/ NC ULTRACOTE COATING YPTOP & BOTTOM) WASHER, CYLINDER -SOLID BRASS, NICKEL PLATED 7/16"0 x 1/2" @ INTERIOR JOINT TOP 7/16"0 x V' INTERIOR JOINT BOTTOM HOUSING -ZINC DICAST,POWDER COATED EITHER CAN BE USED ON EXTERIOR NOTE. MAY BE KEY OPERATED OUTSIDE OR THUMB 24 BUSHING ASSEMBLY DETAIL TURN OPERATED INSIDE SCALE: HALF SIZE 23 BRASS _PUSH SCALE: HALF SIZE 4.000' .500' m o � zo ,224' 2.00 ' 28 DECORATIVE FLOOR TRACK SCALE. HALF SIZE . 33 OUTSIDE CENTER MATE SCALE. HALF SIZE 7/16"0 STAINLESS STEEL NUT HEAD STYLE VARIES 30 38 THUMB SCREW SCALE, FULL SIZE .250'" 1 4-20x1 OR 5//16-16x1 M/CHI E SCREW 5TAINLESS THREA INTERNAL STEEL o 37 T-SCREW INSERT n SCALE: FULL SIZE 39 2X7 ANGLE SCALE. HALF SIZE r 1,0 8' 0.443 .443 II II o ".568' n1 3.444' �g OLD 6.8 CENTER MATE SCALE, HALF SIZE 34 INSIDE CENTER MATE SCALE: HALF SIZE 8 a It �a J • ;'tL �'• TI/i / ZS 400 40b M�hgl O FND____C__TRIR 1 E. HALF SIZE PAGE 4 d 11 FASTENER 9 18" O.C. EXISTING GLA (USE ANY ANCHOR SHOWN IN ANCHOR SCHEDULE). (INSIDE —BACK) OF 38 13 qr 13 6.80" (TYP.) i 9 9 -- C-,1/2" MIN. FOR CONCRETE (OUTSIDE —FRONT) _7R JOCK AND 3/4" MIN. TYPICAL PLAN VIEW SCALE, 3" - 1'-0" USE 1111 BRASS PUSH LOCK OR (11 S/16-18 THUMB SCREEW 1p,I;0 THREADED INSERT f371 AT 1/3 SPAN TO 2/3 AN FROM BOTTOM OF SHUTTER m Gd LEG 17 M . G.093" THICK 6063-T6 UM. ANGLE 1" x 1" MIN1 0 2" x 5" MAX. (ANGLE FI AY BE REVERSED) 9 FASTENER C81 18" O.C. (USE ANY ANCHOR SHOWN 13 IN ANCHOR SCHEDULE). 012 x 1/2" GALVANIZED OR S.S. SMS, 3/16"0 ALL IN 1/4-200 THUMBSCREW INTO POP RIVET, OR 1/4-20 THREADED HOLE. LOCATED (a MACHINE BOLT & NUT 1/3 SPAN TO 2/3 SPAN FROM p ivD.C. BOTTOM OF SHUTTER FOR BLADES 58'-3". USE TWO THUMBSCREWS II EXISTING GLASS BOTTOM ON BLADES a 8 -3 , ONE Ccb 1/3 SPAN LOCKING DETAILS F01 AND ONE AT 2/3 SPAN FROM BOTTOM 110ENTER MATES OF BLADE, TYPICAL. FOR LOCKING Sj' OWN ON RANDOM SHUTTERS, A BRASS PUSH LOCK 23 II DETAILS MAY BE SUBSTITUTED (INSIDE) N 13 Rtl01 N W 9SILL Li to I. I r 0 In 0 Z I USE ((1) BRASS PUSH LOCK 30 OR (11 5/1 18 THUMB 30 SCREW I 0 THREADED IL;L_L�i INSERT 7 AT 1/3 SPAN TO 2/3 S N FROM BOTTOM OF SHUTTER 3 STYPICAL OUTSIDE CORNER CLOSURE CC1 DETAILS WO/CORNER POST - - - NTS ��rF� It57[+• FOR GF TABLE ANGLE (OUTSIDE) 'SILL TYPICAL INSIDE CORNER CLOSURE CC2 DETAILS WO/CORNER POST g�y.5 NTS � •y WI 2 �-1/4-20 THUMBSCREW (OUTSIDE) INTO CENTERMATES 1/3 TO 2/3 SHUTTER SPAN MULTIPLE SHUTTER ASSEMBLY SCALE. 3" a T-0" SEE END STRIP SCHEDULE FOR MAX. SPAN WHEN LOa, 40h OR 40c I40 USE APPROPRIATE STARTER STRIP TO 40 PROVIDE CLOSURE FOR 0 BUILDING CONDMONS, FASTEN STARTER STRIP TO TRACK W/ 2/N10x1" SCREWS . ALTERNATE END STRIP DETAIL AT CORNER. SCALE, 3" - V-0" ANY TRACK W/SCREW BOSSES. SHOWN IN 1"x1" .090" CLIP EXISTING GLASS 7 USE ((1) BRASS PUSH LOCK OR (1) 5/1 -18 THUMB SCREW I 0 T 1/3 PA INSERT 3 AT 1/3 PAN TO 2/3 SAN FROM BOTTOM OF SHUTTER (INSIDE) SILL 215. v (OUTSIDE) USE (1) BOX LOCK AT 1/3' SPAN TO 2/3 SPAN FROM BOTTOM OF SHUTTER MULTIPLE SHUTTER ASSEMBLY SCALE. 3" = V-0" �7�''s aan. DsfTd' 1 PAGE 5 of 11 2 FASTENERS EACH ANGLE 1" x 2" x 1/B" OR2"x2"x1/8" ALUM. ANGLE THREE 3/16"0 ALUM. POP RIVETS OR THREE #12 SMS, TYP. 16.8 ACCORDION SHUTTERS C2 CONNECTION TYPE REFERENCE ANCHOR 'SCHEDULE FOR MAX 5PACING bt CONNECTION TYPE \ IREFERENCE ANCHOR /'r \ SCHEDULE FOR MAX ,! ISPACING ALUM. TUBE 6063-T6 ALLOY _ ________ I wH SEE TARLE A FOR. SIZE. _ — .1 W OLa ALTERNA 11� THRU BOLT Cl CONNECTION TYPE 0 �''' _ REFERENCE ANCHOR •' SCHEDUL 'FOR MAX. 0 13 SPACING GLASS _ V I 0 17 5: I r---_-- --T I I OR DOOR - 3/16"0 ALUM. POP I I I I 17 RIVET OR #12 SMS' (pl 18" D.C. IT \ r I�- MAY USE MALE OR FEMALE LOCK -SLAT) 13 ALTERNATE THRU BOLT C2 CONNECTION TYPE CC3 TYPICAL CORNER CLOSURE DETAILS REFERENCE ANCHOR SCHEDULE FOR MAX. TABLE B (cc4) PRESSURE VS ALLOWABLE LENGTH/ WITH W W H%1B/0 8'-3' 12'-0° E 7110• 11'-9• T-6• IS'-3" 713" 30'-10" 7'-0' 10'-S° 617° 9'-11" 160 6'-2" 9'-2° 20 6'•7" 8.1" 3/16 RIVET OR #12 SMS \ (A 18" D.C. OR 1/4-2 17 _ NUT & BOLT (TYP.1. ,— 3/16"0 ALUM. POP ALUM. TUBE RIVET OR #12 SMS f @ 18" D.C. (TYP.) 6013-TS ALLOY a cc '�@ FOR SIZE. 2 FASTENERS EACH ANGLE 1" x 2" x .093" 6063-T6 ALUM. ANGLE, TYP. THREE 3/16"0 ALUM. o POP RIVETS OR 17 THREE 012 SMS, TYP. 0 o 1"x2"x1/8" 13 0R2"x2"x1/8" ALUM, ANGLE USE MALE OR FEMALE LOCK -SLAT) CC4 TYPICAL CORNER CLOSURE DETAILS NTS SCHEDULE FOR MAX. SPACING EX�STING CONCRETE, BLOCK OR WOOD FRAMING 1-1/2" MIN. FOR CONCRETE FOBLOCK L O K AND /4" MIN, �! FASTENER ld 1 " O.C. (USE ANY AN OR SHOWN IN ANCHOR SC EOULE). .090" 6063-T6 II ALUM, TUBE TYP. ,B ry 2" x 5" x x CONTINUOUS ALUMINUM ANGLE OPTIONAL ANGLE INSII ORIENTATION TYP 1/4-20 MACHINE BOLT W/NUT @ 12" O,C. OR 014 SMS' LO 6" O.C. E (TYP. TOP & BOTTOM) ' �I�/ 5 RQ0- Z W @3 R© J N = O 0 Wi dRZ Se�4 0:0=N= C y,_ Al SEE TABLE 13 F N j z�• O• H)aa SEE z = z TABLE 2 a - - c EE B r FOR MIN. X M W w 5 § § SEPARATION Q w Q m TO GLASS 2 g 143T' _ S OR©OR J j o $)� \14 OR16� g 1,. 1/4" MAX. FROM PIN GUIDE TO BUSHING ~ rI 19 WASHER (TYP.) w 14x3/4" SMS [� 9" D.C. ANGLE TO TUBE CONNECTION r 2„7� 2„ 125„ 6063-T ALUM.TUBE ct o ?g�w 2 CONNECTION TYPE REFERENCE ANCHOR 8 £££ SCHEDULE FOR MAX. SPACING Sa Cb ALTERNATE BUILD OUT. MOUNT SECTION SCALE-3"= V- 0" #12 x 1/2" GAL"' ED� I, (OUTSIDE) °h�l�LT'. ..m 05,f♦g• OR S.S. SMS, 3/16"0 ALUM. Vv��L•1 POP RIVET, OR 1/4-20 !t }; L MACHINE BOLT & NUT SIDE CLOSURE OPTIONS (al 18" O.C. SCALE: 3" = I'll" PAGE 6 of 11 16.8 ACCORDION SHUTTERS C2 CONNECTION TYPE REFERENCE ANCHOR EXISTING 3 •�� Z w SCHEDULE FOR MAX. STRUCTURE O J SPACING a S" MAX. 1/4-20 MACHINE BOLT -" --' mow^ a GLASS w Cf CONNECTION TYPE W/NUT Cd) 12" O.C. OR GLASS F u �, m r OR DOOR FOR ASTM w w r w m REFERENCE ANCHOR 19 OR DOOR N1,1 Im5-4. r w 0 SCHEDULE FOR MAX. _ k14 SMS (m 6" O.C. E FOR AM r w In 2 j -, SEE -TABLE 4 r m= w p SPACING 2• (TYP. TOP &BOTTOM) 8 Wnd Zane 4 7 ¢ Z — �p N k FOR H1'HL SEE TABLE 4 = 13 v) = 0 u , _ _ E k FOR HT61Z 13 I! w 0. w r > SEE TABLE 2 u=i F' o (A w -- '2" = FOR MIN. � w SEE TABLE 2 4 IA � m Z O Z m w 4. 1/4"-20 THRV BOLT W/ m q12 z 1/2" SMS Ff0 12" O.C. SEPARATION r _^ LOCK NUT (m 12" O.C. OR FOR MIN, E F w ¢ O O OR 3/16"0 ALUM. POP TO GLASS u o OQ, D gD�oJ' 12 x 1/2" SMS (la 12" O.C. E.S. SEPARMION L7 H ~ ? RIVETS (d1 6" O.C. OR 1/4"0 L u y w 0O (LJ4 OR 16 d• y OR 3/16"0 ALUM. POP TO CLASS w b ALUM. POP RIVETS @ 12" O.C.Ld Q w RIVETS @ 6" O,C. E.S. \ -, N ¢ I'_ m i6 AND �2 1' FOR AM iR 1/4"0 ALUM. POP RIVETS / 11 I11/4" MAX. FROM PIN Wind Ion, 4 13 r o z eL• (1L 12" O.C. E.S, 1 1/4" MAX. FROM PIN ASSEMBLY 1/ 1/2" TYP O SHI G SEE -TABLE 4 w w m c E Oq ANp�O G ICE TO BUSHING ci 1 'WASHER ITYP.) m,,. u ASSEMBLY WASHER (TYP.) m W 11 GLASS SEE TABLE 2 0) 0 a � 1/2" 1/2" TYP. EXISTING CONCRETE, w 4 CONNECTION TYPE OR DOOR SEFOR MIN. PARATION X � Z M �"UB W BLOCK OR WOOD FRAMING EDGE I REFERENCE ANCHOR Q d `3 m ' 11 -' 1 3 CONNECTION TYPE pIST, I SCHEDULE FOR MAX. TO GLASS = w SPACING AS SHOWN <m Ng EDGE REFERENCE ANCHOR 4 CONNECTION TYPE IN DIAGRAM ON PG. 10) SCHEDULE FOR MAX. REFERENCE ANCf�OR DIII ST. SPACING AS SHOWN SCHEDULE FOR MAX. w r �-C3 CONNECTION TYPE IN DIAGRAM ON PG. 10) SPACING. ALT, FASTENER w o - 5 OR©OR IL'l REFERENCE ANCHOR EXISTING CONCRETE, LOCATION. FRONT, AND g4 OR 16 1/4" MAX, FROM PIN ~ SCHEDULE FOR MAX. BLOCK OR WOOD FRAMING BACK ANCHORS NOT REO'D - - y' GUI E O USHING SPACING. ALT. FASTENER WITH THIS LOCA ,(ON C1 CONNECTION TYPE / LOCATION. FRONT AND REFERENCE ANCHOR - 27: WASHER (TYP.) � � ® BACK ANCHORS NOT REO'D g INSIDE MOUNT SECTION SCHEDULE FOR MA 19 1/4" MAX. FROM WITH THIS LOCATION PIN GUIDE TO O SCALE 3"= V- 0" SPAC 2 CONNECTION TYPE ya BUSHING WASHER O INSIDE MOUNT SECTION - REFERENCE ANCHOR e a (TYP. I SCALE 1 3"= 1'- 0" EXISTING CONCRETE, SPAC NG SCHEDULE FOR MAX. = BLOCK OR WOOD FRAMING EMBED. ( O BUILD OUT MOUNT SECTION Co XISTING CONCRETE, SCA PLE 3"= 1'- 0" TYP. BOTTOM LOCK OR WOOD FRAMING "• you EXISTING CONCRETE, E G ST EXISTING STRUCTURE L � BLOCK OR WOOD FRAMING •4 CONNECTION TYPE REFERENCE ANCHOR EMBED. 2 CONNECTION TYPE EMBED. 1 CONNECTION TYPE REFERENCE ANCHOR 10., S'CHEDULE FOR MAX. REFERENCE ANCHOR SCHEDULE -FOR MAX. SCHEDULE FOR MAX. W 1PACING SPACING SPACING AS SHOWN 1416 = &no IN DIAGRAM ON PG. 9) W 1/2" -- - 1/2" 3 4 li w m N. GLASS FOR AM TTT---...--- �E TABLE4 13 i = N=0 wW»m . tw71� m 1^ 1/2" w 1-W q12 x 1/2'RSMSO(n112" Z w w M FOR ASIM 13 r� w o W w r w m O.C. OR 3/16"0 ALUM. SEE TABLE 2 o N w azm GLASS OR 7 LAI rw»� POP RIVETS @1 6" D.C. X TAg =FZuw In - ' FOR 6 X r m= w o w OR 1/4"0 ALUM. POP SEPARATION TO GLASS ¢ o Q F L N DOOR u O In w SEE TABLE 2 X Z o Z m yy ' GLASS Wlnd Iene 4 13 = T •- r o w RIVETS LID 12" O.C. w w FOR MIN. ¢ � 0 F g L SEE TABLE 4 OR DOOR 8 FOR HINZ S AB to la X Z O Z m ¢ T AND B O O 'MAX. 0. ARMION £ u m TO GLASS `V �Vltrti f w a 7/ 1/4-20 S,S. MACHINE FO IN. ¢ o a r i ASSEMBLY 1/2" U SCREW & NUT (dl SEPARATION a 1/ " TYP, W FROM PIN ¢ DE TO BUSHING SHER (TYP.) w 12" O.C. CLA55 j1 1 I 7/4" MAX. FROM PIN - t ---- MAX. FROM PIN X GUIDEBUS w 1 11 4' CONNECTION TYPE ' w o __ 1/2'• GUIDE TO BUSHING 7�7R 2O WASHER ITYP.) ;a•' •. 1L- •,��' iv X WAS i WASHERR (TYP..) DGE I REFERENCE ANCHOR SCHEDULE FOR MAX. - iG `, r / EXISTING CONCRETE, pIST, SPACING AS SHOWN 2 CONNECTION TYPE N = In BLOCK OR W000 EXISTING CONCRETE, 4 CONNECTION TYPE IN DIAGRAM ON PG, 101 REFERENCE ANCHOR FRAMING BLOCK OR WOOD FRAMING REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING j� a •� '$ " ^T-. ._ , ,;, ©x03" x 1/4" CONT. 5 CONNECTION TYPE 012 x 1/2" SMS CD 12'• O.C. OR 3/16"0 ALUM. SCHEDULE FOR SPACING. ALT. RASTENER MAX. EXISTING CONCRETE, // . .• 6063-T6 ALUM. ANGLE (MAY BE REVERSED REFERENCE ANCHOR SCHEDULE FOR MAX. POP RIVETS Cm 6" O.C. LOCATION. FRONT BACK ANCHORS AND NOT REO'D BLOCK OR WOOD FRAMING i+) fi• ;tc m fe_ Osfr�.Y iag AS SHOWN DASHED) SPACING OR 1/4"0 ALUM. POP WITH THIS LOCATION - RIVETS C8 12" D.C. Op WALL MOUNT SECTION O CEILING / INSIDE MOUNT SECTION O WALL/BUILD OUT ' SCALE + 3"= V- 0'• SCALE 3"= 1'- 0" ! SECTION SCALE : 3"= V- 0" PAGE 7 of 11 i' FOR ASlfd. WrId Zme p SEE TABLE 4 _A_ z w+ �? EXISTING STRUCTL GLASS & FOR Hta 13 OR DOOR SEE TABLE 2 Do N FOR MIN. SEPARATION ir 0:w w o s r TO GLASS r U N w.�. O 1/4"0 ALL POINTS C I- Q Z 0 J N m Q SOLID SET ANCHORS N w u s a> p J WITH 7/8" MIN. EMBEDMENT IN —T X M M X z CONCRETE OR Z' 00 BLOK ` zl-W ZF~ Z 0 G N 3" MIN. ED. DIST. - _ /2 1 1/4" MAX. FROM PIN GUIDE TO BUSHING WASHER (TYP.) GLASS OR DOOR TWO 1/4"0 WOOD LAG SCREWS @ 24" O.C. MAX. WITH 2" 3" MIN. THREADED PENETRATION ED. DIST. "T" INTO CENTER OF STUDS TRUSSES EMS. "T' 14 SMS @ MIDSPAN BETWEEN STUDS FOR TRACK TO 1" x 4" PLYWOOD & TUBE CONNECTION STUCCO FINISH 1" x 4" x .125" N 6063-T6 ALUM. TUBE 1/4"0 ALL THIS DETAIL MAY POINTS SOLID ALSO BE USED THIS DETAIL TO BE USED WHEN STUD SPACING SET ANCHORS WITH 7/8" MIN. AT TOP EXCEEDS THE MAX, ALLOWABLE ANCHOR SPACING. EMSEDMENTIN OWALL MOUNT SECTION CONCRETE OR BLOCK SCALE . 3"= l'- 0" EXISTING STRUCTURE ALT. LEG DIRECTION SEE BEAM SCHED. & HIS r NOTE JiSIT PAGE R1/4-20 MACHINE BOLT W/NUT RNL G H ANCHORS @ 12" O.0 OR N14 x 3/4" SMS 6" O.C. ALUM. BEAM (SEE BEAM — SCHEDULE THIS PAGE FOR ACCESS H01!E BEAM DESCRIPTION & MAX. HORIZONTAL SPANS) li z w J 7 p �~ 14 6 Cc pc1M Wlnd Zone 4 v M > w 'ABLE 4 &FOR Il12iZ 73 -; Q Z= m N ,.A BLF 2 FAR MIN. wd WFj BOX BEAM SCHEDULE ��e. r,.ILW�ILJ O$�ii�mi%�+m���es�����ii�, TO a T AU GLASBO III TS y w m o z' * USE 2X3X1/4 OR 2X5X7/4 ANGLES FOR 2X5 & 2X8 BEAMS w a 0 USE 2X5X1/4 ANGLES FOR 2X8 & 2X10 BEAMS W DULE FOR li. Lr z$ APED NUMB FRS Z9F ] i J v=i BEAM SCHEDULE NOTES: 5 6 1416 III" MAX. FROM PIN GUIDE A. USE BEAM SCHEDULE FOR DETAIL J . I� TO USHIN WASHER (TYP.1 J2. TOP & BOTTOM BEAMS MAY BE USED TOGETHER OR IN COMBINATION WITH OTHER CONNECTION DETAILS. - •- WHERE USED TOGETHER, BEAM MUST BE LIMITED ALUM. BEAM (SEE BEAM TO TOP BEAM SPANS. =c b SCHEDULE THIS PAGE FOR J3 LAP BEAMS ARE NOT ALLOWED.a BEAM DESCRIPTION & MAX. HORIZONTAL SPANS) J4 ALL BEAMS &ANGLES TO BE 5063-T6 ALLOY. E BEAM SCHED. & 1/4-20 MACHINE BOLT W/ TE A THIS RAGE GLE SIZE & FOR NUT Co) 12" O.0 ANCHORS OR 1114 x 3/4" SMS @ 6" O.C. O D T. LEG DIRECTION I, ACCESS HOLE I.IMAX. DESIGN LOAD e x 72 PSP - BEAM SPAN SECTION FOR ASTM Wind Zone 4 `GLASS F c O 1'- 0" J SCALE SEE TABLE 4 &FOR 8)BIZ SEE TABLE 2 FOR MN. OR DOOR 73 7 in B", SEPARATION TO CLASS 2:II w EXISTING WOOD Z TRUSS OR RAFTER ', 1/2" a @ 24" MAX. O.C. -1/ i a EXISTING FINISH I' j MATERIAL 1/4" MAX. FROM PIN GUIDE 1" x 4" x 1/8" 6063�.T6 k TO BUSHING WASHER (TYP.I ALUM. TUBE W/ THREE 1/4" TILE (TYP.) 1/4"0 WOOD LAG 1• Ii -- FINISH MATERIAL SCREWS WITH 2-3 �4" gff MINIMUM THREADEDI "T" 3/4" PLYWOOD 1/4"0 A325 GRADE THRU BOLT @ S" O.C. PENETR. IN WOOD EACH RAFTER OF TRUSS 24" O,C. MAX. WHERE @ it OR 5/16"0 A325 GRADE THRU BOLT @ 12" D.C. TUBE EXTENDS BEyyONDA GALV. OR S.S. LAST TRUSS HAtA 4. p Tc �— 1/4"0 ELCO ULTRACON TO CONCRETE/CMU 8", EXTEND TUBE NEXT TRUSS. r0 O.C. W/1-1/4" MIN. EMS. OR 1/4"0 LAG SCREW @ 9" O.C. W/1-7/8" } MIN. EMS. IN WOOD SG•0.42. TO O.SS. ".' 1/4-20 S.S. MACHINE,SCREW BETWEENITRUSSES (� EXISTING CONCRETE, 24" O.C. IN WITH 1/2" 'ACCESS HOLE ON HOLLOW BLOCK OR - WOOD FRAMING, SEE ';i 2" x 5" x 1/8" CONT, 'ALUM. ANGLE (6063-T6) BACKSIDE OF TUBE OR @ 24" O.C. MAX. IN BETWEEN 014 SMS ANCHOR SCHED. BASED ON TYPE OF STRUCTURE (MAX. DESIGN LOAD • 72 P.S.F.) I LOAD : 72 P.S.F THRU DETAIL (MAX. DESIGN OPASS SCALE : 3'• 1'- 0" 2 1/2" I >* m I i iI w li n m 5 6 w I- w 2" x 4" x 1/8" 6063-T6 „a• w j j ALUM. ANGLE W/ THREE 1/4"0 WOOD LAGS'' SCREWS WITH 2-3/4" �/ r-wswp 13 ✓: _ MINIMUM THREADED �• sF 'A 1, z vw C M J O 10 PENETR. "T" IN WOOD @ EACH RAFTER OF TRUSS, �•b i X Z _w Z x a Q ~ u 24" O.C. MAX. WHERE ANGLE EXTENDS BEYOND / Q y LAST TRUSS MORETHAN/i•^re•�' 0", EXTEND ANGLE TO li a NEXT TRUSS. d1 1 L'i MOUNT SECTION OTRUSS SCALE : 3"= 1'- 0" S4� +�f PAGE 8 of 11 I GLASS OR Z GLASS OR SEEM DOOR O DOOR " SEF FORw w ^ 0• �F FOR: w i Wlndyaj O_ S m Vnd Zone 4 w J SB)� SEE d: FOi u w= j w Q �, ¢ i = SEE TABLE 4 SEE TABLE 2 ¢ r H< M = ~ m T0: I' } FO'A SEOPAQ= w a w I- = FOR MIN. SEPARATION �= V1 p p £z W Mee Q 0 I 2: tA V i 13 X QREFERENCE ¢ rn C1 CONNECTION TYPE w m ANCHOR 0. SCHEDULE FORQ IA SPACING.250'• .250"4"0 TAPCON 24" C4 CONNECTION TYPEC. WITH 1-1/4' MIN. REFERENCE ANCHORBED. SCHEDULE FOR MAX. wSPACING EXISTING CONCRETE ONLY.WOOD ORBLOCK FRAMING & WQOD ANCHORS / �10T ACCEPTABLE / EXISTING CONCRETE OR BLOCK ONLY. WOOD O WALL MOUNT 5I tmj;\ FRAMING 9, WOOD ANCHORS SCALE 3"= P- 0" DisT� \\ O DECORATIVETFLOORTTRACK DETAIL ORECESS SILL DETAIL \ SCALE : 3"= V- 0" SCALE: 3"= V- 0" \ 1/4" MAX. FROM PIN GUIDE TO BUSHING WASHER ITYP,1 ' TYP. BOTTOM I' APPROVED MOUNTING Wll\�-AP CONDITION, MIN. OF TWO PER PIECE PROVED FASTENER AND SPACING WO FASTENERS PIER CUTOF PIECE TYP. SECTION FOR SHUTTERS Pl SCALE: 3" - 1 -0 1"x1"0/8" & 1"x2"x1/8" 6063-T6 ALUM. ANGLE CUT TO OF CUT SHUPROVIDE TER EXTRUSIONST FRONT AND BACK. WHERE FRONT OF EXTRUSION IS IS NOT REINFORCEMENT 0� B. APPROVED MOUNTING PIECE TION, MIN. OF TWO PER APPROVED FASTENER AMND TWOFASTENERS PIER CUTOF PIECE TYP. ALTERNATE SECTION FOR SHUTTERS P2 SCALEI 3" - V-O" OR aw �m ��=~m =L'0VO Xz .4 'z £ uQ <tn 18b EXISTING STRUCTURE EXISTING FINISH MATERIAL 2" -------- ----- ---------- ----- 4•, M. RADIUS HEADER MOUNTED PARTIAL ELEVATION SCALE: 3" = 1 -0' 5 6 CUT IN 4" INTERVALS `.ti+'i i•i:Nl`::, ;� WASHER IT OR U E (SEE DETAIL 1 FOR ADDITIONAL•` INFO). TTOP & BOTTOM. FASTENER P EACH 4" CUT SEE ANCHOR SCHEDULE BASED '�� ON C4 CONNECTION TYPE TO r R � ~ VERIFY ANCHOR SPACING 'vF:u"` IS ACCEPTABLE 13 �' w v v v v v EXISTING FINISH MATERIAL- � e000b :r �y 17n b i:'Ic'm b b vvwwnv 1/4" MAX. FROM I 1/2" - TO BUSHING WAS 1/4-20 MACHINE BOLT W/ NUT (0 2" D.C. 19 CUTRM CURVE (SEED TAILT P� ® 1 1 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE FOR MAX. SPACING (FASTENER (d! EACH 4" PIECE n CURVED TRACK SECTION DETAIL SCALE : 3"- 1'- 0" P2 � P1 PAGE 9 of 11 6.8 ]ANCHOR SCHEDULE FOR CONCRETE SENERSPACIN(i (INCHES) RtquIRED PORVAPIOUIS DESIGN LOADS AND SPANS .r —1VIEDGE DISTANCE �W���� 7�1111IIIY111W\I11111\\Ill- mom onumm©©©mm mmmumommnoomoo©o mmm ®mo moi/mm©oomoo©nmo©o© 7,�111\\11W11,11111111111111 114; ORMEC mm����mm©�©m�© ©mm�mmmm���m���� ammo©am©©o©©mm©o©m©©©omo©o© mMIN. 1-1/4" EDGE DISTANCE NEWW", lr=-- II1111PI11,.,� mm1300013m00©mm©0©mmmmmmmmmmmm0D0 mmm©o©mm©©©o©©i/mmmmmmmomomo©o© r° mmm©o©o® umm mm000m0000mo©©o MIN, 2-5/8' EDGE DISTANCE MIN. S-1/4- EDGE DISTANCE mmmmmmmmmmmmmumummmmmmmmmmmmmmm E ,.r. mmmmmmmmomommonommmmmmmmmmmmumo mmmmmmmmomumo©o©mmmmmmmmmmmoomo :• r a �mmOm' Om�©�©m00��mmmmmm00m' �m��0� MIN.3-1/8' EDGE DISTANCE ®mmMOMMOMMOMMUMO1300MOMMOmmmm�m� ).ntllllul=enKn1:1:, mmmmmmmmOmOmO©0©mmmmmmmOm�mm©0© mmmmmm' mm0m�m����mmmmmmm�m�m���© ra .• r omo©©omo©©omo©©omoo©omoo©omoo©o �mmmmmmmmmmmmnmommmmmmmmmmmmomo ]IJ�111111111MIIIIIWIIIl111_ mmmmmmmmomomm000mmmmmmmmmmmmomo �mmmmmmmmm�mo©o®mmmmmmmomomo©oo r :ar �mm�m�m�©0©m©�DDmm0m0m�©��m©©�Q �m©000m©000m©000m©©o©m©©o©m©©o© 2 x 5 YP. 2 x 5 K� OUTSIDE TOP FLANGE ANCHOR SEE SPACING' 'SECTION X) O � O 0%O '1 xS TYv'�1 x S (� INSIDE 3 OR Q4 HEADER /SILL BOT. FLANGE ANCHOR (SEE SPACING SECTION X) SIDE CLOSEST TO OPENING NOTE: "S" INDICATES ANCHOR SCHIOULE &ACING. SPACING DIAGRAM FOR Cl CONNECTION TYPE: - C1 CONNECTION TYPE USING PIECE 3 OR 4 7 / 0 COMBINATION x T P 1/ 1 COMBINATION 9 / 0 COMBINATION ' O �1 x 5 I7YP.j� 2 x 5 ITYP.1 NOTE, "S" INDICATES ANCHOR SCHEDULE SPACING. SPACING DIAGRAM FOR C3 & C4 CONNECTION TYPE: - C3 CONNECTION TYPE USING PIECE WITH OUTSIDE ANCHORS ONLY C4 CONNEC ANCHORS E USING PIECE (ID OR ® WITH OUTSIDE ANCHOR NOTES: 1, SPANS AND LOADS SHOWN HERE ARE FOR DETERMINING ANCHOR SPACING ONLY. ALLOWABLE STORM SHUTTER SPANS FOR SPECIFIC LOADS MUST BE LIMITED TO THOSE SHOWN IN TABLE 1 k 3 (P0 1). 2.ENTER ANCHOR SCHEDULE BASED ON THE EXISTING STRUCTURE MATERIAL, ANCHOR TYPE AND EDGE DISTANCE. SELECT DESIGN LOAD GREATER THAN OR EQUAL TO NEGATIVE DESIGN LOAD ON SHUTTER AND SELECT -SPAN GREATER THAN OR EQUAL TO SHUTTER SPAN, 3.SEE MOUNTING SECTION DETAILS FOR IDENTIFICATION OF CONNECTION TYPE. 4,E)aSTINO STRUCTURE MAY BE CONCRETE, ASTM C-00 HOLLOW CONCRETE BLOCK OR WOOD FRAMING. REFERENCE ANCHOR SCHEDULE FOR PROPER ANCHOR TYPE.BASED ON TYPE OF EXISTING STRUCTURE AND APPROPRIATE CONNECTION TYPE. SEE CONNECTION DETAILS FOR IDENTIFICATION OF CONNECTION TYPE. S.THE CONTRACTOR IS RESPONSIBLE TO ENSURE THE ANCHORS ARE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. EMBEDMENT LENGTHS SHALL BE AS NOTED AND DO NOT INCLUDE STUCCO OR OTHER FINISHES• &WHERE EXISTING STRUCTURE IS WOOD FRAMING, WOOD FRAMING CONDITIONS VARY. FIELD VERIFY THAT FASTENERS ARE IN70 ADEQUATE WOOD FRAMING MEMBERS, NOT PLYWOOD. FASTENING TO PLYWOOD IS ACCEPTABLE ONLY FOR SIDE CLOSURE PIECES. 7.WHERE LAG SCREWS FASTEN TO NARROW FACE OF STUD FRAMING, FASTENER SHALL BE LOCATED IN CENTER OF NOMINAL 2' x 4' (MIN.) WOOD STUD. 3/4' EDGE DISTANCE IS ACCEPTABLE FOR WOOD FRAMING.LAG SCREWS SHALL HAVE PHIWPS PAN HEAD OR HEX HEAD. &MACHINE SCREWS SHALL HAVE MINIMUM OF MAY HAVE 1 2' ENGAGEMENT OF TTRRUSSS HEADS AD, WAFER HANCHOREAD AND BOL»EUO.N AN HEAD. ® DESIGNATES ANCHOR CONDITIONS WHICH ARE NOT ACCEPTABLE USES. • DESIGNATES ANCHORS WHICH ARE REMOVABLE BY REMOVING MACHINE SCREW, NUT OR WASHER WINONUT. 9. FOR 5/10'0 ELCO CRETE FLEX, CONCRETE r-3.35 KSI, FOR ELCO UL7RACON, CONCRETE r 3.5 KSI, FOR ITW TAPCON, CONCRETE V-12 KSI, OTHERWISE MIN. Fc t4 3 KSI. yyN�y2$$$yDyr �G �B ida y•� W NT SS PAGE 10 of °'1 l **See Attached Engineerinq & Product Approval** Existing Pool Enclosure Window Sizes — Minimum Pressures _LL F #3 #1=135" x 86" (SeeAtttached Sheet) #2= 125" x 86" if #3= 127" x 86" " Existing Patio #4= 132" x 86" " Under Structure Roof SITEwADDRESS: 5800 Silver Oak Drive Fort Pierce, FL 34982 CONTRACTOR: South Florida Aluminum Products 4801 S. US-1 Fort Pierce, FL 34982 SCALE: NOT TO ANY SCALE (OPENING LAYOUT) BRIEF DESCRIPTION: To install aluminum accordian shutters over r r covered patio openings. of (4) Openings being covered.