Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSFee Due: PTO I Re"ceiFt# pc�a&-;g Permit # ago?. Oo`� o St. Lucie County Building & Zoning Department so 2300 Virginia Avenue Fort Pierce, FL 34982 8 V Eo •'OLORlO 772-462-1553 LUC% APPLICATION FOR REPLACEMENT OF co�'n�v WINDOWS, SKYLIGHTS, DOORS & OVERHEAD GARAGE DOORS 1. LOCATION/SITE ADDRESS: \ O 1 SECT TWP RNG MAP ZNG LU �- IMT 2. PARCEL ID NUMBER I -1�bc I — ( n (05 � �(� iaw —j 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY:�� c l 6cor 4. TYPE OF STRUCTURE: ❑ SIR LAY OTHER 5. OWNER INFORMATION 6. CONTRACTOR INFORMATION Name: P1(�rr1(�`� uS j � FL Reg/Cert #: Address; s w Q ` �t�.r'� I�� County Cert#: 1 C\ 00- City: � , 1 e u-- State: ( Business Name: Zip: ,22 q5' Phone: (oS- 93�Phone L4(DO'-7(D,-�DFax (4 Product Table 1606.2B Minimum Design Design Model NOTICE OF ACCEPTANCE # Pressure Pressures Manufacture Number FLORIDA # ** 15' maximum height 130 mph 140 mph Windows & Skvlights Exposure B 40.7 47.2 Exposure C ** 49.2 1 57.1 Swing & Garage Doors Exposure B 38 1 44 Exposure C ** 45.9 1 53.2 7. VALUE OF CONSTRUCTION: $ l!1J OWNER'S AFFIDAVIT: I certify that all of the information contained in this application is correct and that all work will be done in compliance with all applicable laws regulating construction and zoning. : pl�— I)Pr ,ice//"-Z FMNT QUALIFIERS/O S % STATE OF FLORIDA, COUNTY OF 1j,A/ . 2'eJ BI�V j/(/ /'/ NOTARY PUBLIC SIGNATURE OF QUALIFIER/OWNER ACKNOWLEDGED BEFORE ME THIS k DAY OF — IS �LYKNOWNT(JOR WHO HAS PRODUCED AS IDENTIFICATION. R__.. q�qr at NQtar}IRuhlio State of Florida 3' 11; ,Janet Rudd (se ) TYPE OR PRINT NAME O ja My mission DD595830 w �O Ex Tres 09/17/2010 COMMISSION NUMBER Window, Skylight, Doors, Garage Door permit application 7/18/05 dmg NOTICE TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. ❑ Attach 2 copies of the NOA or Florida approval with details to the product being used INSTRUCTIONS Please complete all information in the space provided. All information must be Printed (use black or blue ink only) or Typed. This application for replacement of Windows, Skylights, Doors & Overhead doors to be used for only those activities that are not otherwise included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition to the replacement of Windows, Skylights, Doors & Overhead doors, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. LOCATION/SITE ADDRESS: .............................................. Indicate the street address, or general location, of the property on which the building activity is taking place. 2. PARCEL ID NUMBER: ........................................................ Indicate the Property Tax Identification Number for the property on which the building activity is taking place. '3. DESCRIPTION OF PROJECT OR WORK ACTIVITY........ Briefly describe the building activity under permit application. 4. OWNERS INFORMATION: ................................................. Indicate the name and address of the owner of the property on which the product is to be installed. 5. CONTRACTORS INFORMATION: .................................... Indicate the State of Florida (if applicable) and St. Lucie County contractors registration numbers, and the name of the business doing the work. 6. VALUE OF CONSTRUCTION: ........................................... Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. The value of construction is used to determine the amount of permitting fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. All applications for Permits are to be submitted to the St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Following the issuance of this Windows, Skylights, Doors & Overhead doors replacement Permit, the scheduling of all required inspections maybe made by calling (772) 462-1261. SLCCDV FORM NO: 006-05 Window, Skylight, Doors, Garage Door permit application 7/18/05 dmg i »1 .F• File Edit View Tools Window Help l' / 4w 1 285 or; ® '©• TsiC area €€ Layers .,....,..,.x...---------- . ......:� ,.,.....::: mM...m... µ..._,.,.�._...w w.�....•,�..,,.�,.,,,,,,a,,. [[[ (KI ❑ TVC area ` M ❑ Sections ti M County Boundary4, 0+ ❑ Historic Structures W 0 Address Master Q ❑ Hydrology Names Ot Road ROW Dimensions ❑ Lot Lines - 3a II ❑ Block Numbers Anno f l7 i7 Lot Number Anno E p ❑ Parcel Dimension Anno ` i (❑ Managed Care Facilities I51 Municipalities s II ❑ ROW GI+ (� Major Roads 0 :G Streets ❑Historic Sites If r 18103 .o Q ( Hydrology t 8101 z ❑ Annexations R& r 0 Parcels •.. _: Rs -a - _ i' ' C#I ❑Flood Zones ,d p Future Land Use..r i Zoning'., y '. ` ( 0 ❑ Vindzones ( L+ ❑ Mobile Home Parks III ❑ Subdivisions E E) ❑ Solid trPaste Service Aret D Major Water a: ❑ Zip Codes Aerials 2003 L0 ❑ Aerials 2006 i 0- County Base y e ij RU R:r 4 RU Rs 4 i YJ .kV .. ,,F _ ... . 711 Ii,P D i D ha Tuesday, Jul 15, 2008 01:32 PM -?�Z Building Code Compliance Division y Receipt 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stl ucieco.goy/ce Date: 15 July 2008 Receipt M 0000064268 Job Address: 8101 BAYARD RD •ermit Number: SLC- 0807-0268 Received By: humphreya Amount: $80.00 Paid With: CK �redit Card Number: Check Number: 8608 Paid By: GARAGE DOOR DEPOT Sign: I Florida Building Code Online i Page 1 of 6 A.42 BCIS Home j Log In ` Hot Topics 1 Submit Surcharge ; Stats & Facts Publications FBC Staff BCIS Site Map g Links ':. Search .Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL3026-RI Application Type Revision Code Version 2004 Application Status Approved Comments Archived Product Manufacturer Clopay Building Products Company Address/Phone/Email 8585 Duke Blvd. Mason, OH 45040 (513)770-6062 mwesterfield@clopay.com Authorized Signature Scott Hamilton shamilton@clopay.com Technical Representative ;g Ew Address/Phone/Email . J � Quality Assurance Representative Address/Phone/Email 0Y07 -0 Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer E Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Gary Pfuehler developed the Evaluation Report Florida License PE- 49850 Quality Assurance Entity Intertek Testing Services NA Inc Quality Assurance Contract Expiration Date Validated By John E. Scates, PE i.....' Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Standard ANSI/DASMA 108 Year 2002 h4://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsjfpmx6jjBWE... 7/11/2008 MODELS OPTIONAL DSB OR 1/8' ACYRUC RITES THE OPTIONAL GLAZING SHOWN ON THIS DRAWING MEETS THE STANDARD INSULATED AVAILABLE OPTIONAL ACRYUC GLAZING IS WIND LOAD REQUIREMENTS OF THE FLORIDA BUILDING CODE 24 GA 84A 94 - PLASKOLITE OPTIX OR LUCITE CP APPROVED OR WTERNANONAL BUILDING CODE BUT DOES Eff MEET THE IMPACT RESISTANT REQUIREMENT FOR WWOBORNE DEBRIS 25 GA 73 75 190 1500 CC2 PLASTIC IN ACCORDANCE WITH IBC/FBC REGIONS REF. CHAPRERI6 FBC BC 3" TALL U-BAR 2606 (SEE SECTION B-B) - 2• THICK 20 GA. GALV. STEEL (1) INTERMEDIATE STILE 1TACHED W TOG-L-LOC (TOP & BO D URETHANE ADHESIVE (ALONG CENT 20 GA MIN. END STILES ATTACHED TO DOOR SKIN WRH PATEN1TTl. TOG-L-ROC SYSTEM' - -� A TOP. BOTTOM `& CENIT7T). 25 GA MIN. GALV. SKIN COATED WITH GALV., -'I 3' -FI r IS DOOR TOMEETS H OR (DEEDS HE DESK! LOADS FOR THE WIND SPEEDS LISTED BELOW ROADS F O TO THE FLORIDA BLOC. CODE OP - BAKED -ON PRIMER, AND A LTlLI(ED-0N POLYESTER COAT APPLIED TO BOTH 1-7/8' ;L ;! ;L OR IBC ASCII FOR THE FOLLOWNG SIDES OF STEEL SKIN. ---lT Ol '0 •' ►% fl CONDITIO S: 1) ENCLOSED BUILDING, 2) DOOR HAS 2' OF WIDTH IN BUILDING'S END ZONE, 1+ 31 IMPORFANCE FACTOR OF 1•.0 4 ANY OF SLOPE AND SOx: FACTOR DENSITY POLYSTYRENE FOAM INSULATION 1-5/15' THICK WRH NNYL FWRCELL EMCIG7t (0lsuwm 400E15 ONLY) 1B G4. GALV STEEL TOP ROLLER BRACI�T. FACH BRACKET ATTACHED W/(3) 14x5 8 SHEET METAL I WIND SPEED MPH 5110 120 120 130 m IXPOSURE LEVEL B or C B ClB C S. I LJ MEAN ROOF HEIGHT 30' 30' 15' W. -SHIP LAP JOINTS. LOCK POSITION END SLIDE BOLT 0 (BOTH SIDES) STILE LOCK ENGAGES 153 TWO POINT LOCKING INTO VERTICAL x TRACK ONE LOCK ON 0 ONE 3' TALL x 20 GA. EACH SIDE U-BAR (MIN. YIELD: 50 KSI) OF DOOR. PER DOOR SECTION, EXCEPT INSIDE SLIDE BOLT • BOTTOM SECTION WHICH REQUIRES TWO U-BARS. LOCK OPTION OPTIIO ONAALnOVNLN015 ----� A OPTIONAL OUT$IDE KEYED LOCK POSITION MAX. POR WIDTH 9'0' DOORS UP TO 7'-0" HIGH CONSIST OF 4) SECTIONS (SHOWN). #1:TAPPING /8' SH€ET METAL SCREWS DOORS OVER 7'-0" HIGH CONSIST OF (5� SECTIONS (NOT SHOWN). VERTICAL JAMB ATTACHMENT (���-_-9-D BLOCK OR 2:000 !9I MIN. CONCRETE COLUMN, �'x4 SLEEVE ANCHOR BDLTS ON 24- CENTERS (BOTH C-90 BLOCK OR 2,000 PSI MIN. CONCRETE) OR G C! PSI MIN. TAPCON SCREWS ON 24" CONCRETE). WASHERS NCLUEDDEDRWITH 000 1/4'S SELF SLEEVE ANCHDRS, 1' O.D. WASHERS REQUIRED SCREWS. WITH TAPCONS. ANCHORS MAY BE COUNTERSUNK 14 GA. END HINGES 18 GA. INTERMEDIATE HINGE (BUT NOT REQUIRED) TO PROVIDE A FLUSH - MEW 'B" VIEW I MOUNTING SURFACE HORIZONTAL JAMBS DO NOT TRANSFER LOAD. 14 GA. GALV. STEEL END HINGE EACH FASTENED TO END STILES. W/(4) /14.5/B' &F� 1/4fTAA'xCL..3/54RESEELF TAPPING SCREWS. GA DATE DESCRIPTHN 5/2000 ADDED LHR TRACK OPTION NOTE; DEL MIN 82 90 2000 QTY. (1) WAS (2 TRACK - BOLTS 2003 CLARIFY GLAZING OPTIONS '2004 ADDED INSULATED M/N 190. 1500 ZOOS UPDATED CODE REF. HORIZONTAL TRACK SUPPORT BY DOOR INSTALLEI 3 GA. GALV.STEM STEEL FLAG BRACKET. FASTENED TO WOOD JAMB WITH rEACH 3) 5/16'x1-5/8' WOOD LAG SCREWS. c00 CK CONFIGURATION x o 0 2' GALV. STEEL TRACK, NUB MIN. TRACK THICKNE55:.060. 0 x z TYP. 2-1/2'x12 GA. GALV. STEEL TRACK BRACKET. (4) TRACK BRACKETS PER SIDE z 0 NOTE; DOUBLE TRACK LOW HEIS AVAILABLEEROOM AS AN OPTION 13 GA GAUV. STEEL BOTTOM BRACKET. ' uvvSiViv�m. ATTACHED WITH TWO 114.5/8' SHEET METAL SCREWS FRONT FRAME WITH U.V. ALUMINUM EXTRUSION COATING ON OUTSIDE SURFACE h VINYL WEATHERSTRIP. SECTION A -A (SIDE VIEW) STOP MOULDING BY DOOR INSTALLER (TO SUIT) VERTICAL JAMB ATTACHMENT (WOOD FRAME BUILDINGS): 2x6 YELLOW PINE JAMB—,�20 GA. MIN: GALV. STEEL END STILE 1/Z'x3' LAG SCREWS ON 24` CENTERS. 1' O.D. WASHER REQUIRED. LAG SCREWS MAY BE COUNTERSUNK 20 GA. GALV. STEEL INTER. SITS;;, (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING SURFACE HORIZONTAL JAMBS DO NOT TRANSFER LOAD. 1 BRACZKETS WITH ONE 2' GALV. STEEL TRACK FASTENED TO 12 GA. GALV. STEEL TRACK BRACKETS. TRACK ATTACHED TO EACH BRACKET WITH ONE 1/4.4/8' BOLT k NUT OR TWO 1/4- DIA. RIVETS. DIA. SHORT STEM, 10 BALL STEEL ROLLER. JAMB CONTGURATIO NOTE 2: THE DESIGN OF THE SUPPORTING STRUCTURAL ELEMENTS SHALL BE THE RESPONSIBILITY OF THE PROFESSIONAL OF RECORD FOR THE BUILDING DR STRUCTURE AND IN ACCORDANCE WITH CURRENT BUILDING CODES FqR THE LOADS LISTED ON THIS DRAWNG_____ INTER. STILE HINGE rXEN A. OATO INTER' � 5 LEES W ) 14x5%B' SHEEP METAL SCREWS. OUTSIDE KEYED LHR TOP BRACKET HANDLE DOUBLE HORIZONTAL TRACK n A OPTIONAL 10 SCREW GLAZING WINDOW LTIE MOLDED INSIDE LITE RETAINER SECTION a-B #Bx3/4' PAN HEAD SCREW (10 SCREWS PER LIM SNAP LATCH ENGAGES ONTO.VERTICAL TRACK. INTE ONE SNAP LATCH ON STIL EACH SIDE OF DOOR. OUTSIDE END HANDLE STILE INSIDE HANDLE _OUTSIDE KEYED LOCK DO B F TRA K SNAP LATCH LOCK OPTION LOW HFADROOM OPTION Clopay CLOPAY BUILDING PRODUCTS COMPANY 8585 DUKE BLVD. MASON, OH 45040 Building Products (513) 770-4800 Company - Cbpq MWrOk. All Right. 11—r L END STILE LOCK BAR ENGAGES IN • i TRACK ON EACH SIDE OF DOOR. OUTSIDE KEYED LOCK LOCK BAR LOCKINGINK TOM ATx} DESIGN ENGINEER: MARK WE FIELD, P.E. _ _ FLORIDA P 3 IP:EPL !M. DIGN LOADS: +30:0 P;S:F. 8 32`F. TEST LOADS: +45 P,.S,F. & -.48.0 P:S.F; --- VI/DILWD TAT71& - -KA1CD IZE S NOTED W 5 9'W x B'H 9/23/95 DEsCRIPTIm BY. MWW 73/75/84A/94, 9'W; +30/-32 D BY. B DRn m 02110 09 Florida Building Code Online , - Page 2 of 6 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FBC 1714.5.3.1 Method 1 Option D 06/03/2005 06/09/2005 06/16/2005 06/29/2005 Summary of Products Go to Page '� Page 1 / 2 FL # Model, Number or Name IlDescription ri6,1 W3-16: 1000, 183, 1001, Steel pan (min. 25 ga.) Double Car (9'2" to 16'0" 187, 52, P2GF, 12SR wide) WINDCODEO W3 Garage Door Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- PTID 3026 R1 T 1000W3-16-Rev02.3df PTID 3026 RI T 1000W5-09-Rev02.pdf Other: 1) Design Pressures: +20/-21 2) For Use PTID 3026 R1 T 1000W5-16-Rev02.pdf Outside the High Velocity Hurricane Zone PTID 3026 R1 T 4300W4-09-Rev02.pdf PTID 3026 R1 T 4300W4-16-Rev02.pdf PTID 3026 R1 T 4300W4-18-Rev03.odf PTID 3026 R1 T 4300W6-09-Rev02_pdf PTID 3026 R1 T 4300W6-16-Rev02.pdf PTID 3026 R1 T 4300W6-18-Rev02.pdf PTID 3026 R1 T 73W3-16-Rev02.pdf PTID 3026 R1 T 73W4-09-Rev02.pdf PTID 3026 R1 T 73W4-16-Rev03.odf PTID 3026 R1 T 73W4-18-Rev02.pdf PTID 3026 R1 T 73W5-09-Rev02.pdf PTID 3026 R1 T 73W5-16-HY-Rev02.pdf PTID 3026 111 T 73W5-16-Rev02.pdf PTID 3026 R1 T 73W6-09-Rev02.pdf PTID 3026 R1 T 73W6-16-Rev02.pdf PTID 3026 R1 T 73W6-18-Rev02.pdf PTID 3026 R1 T 94W6-18-Rev02.pdf PTID 3026 R1 T C11W4-16-Rev02.pdf PTID 3026 R1 T C11W5-09-Rev02.pdf PTID 3026 R1 T C11W5-16-Rev02.pdf PTID 3026 R1 T Clopay EPS Manual.pdf PTID 3026 R1 T Clopay Semi -Custom Reserve Supplemental Manual.pdf PTID 3026 R1 T Clopay ShiDlap Pan Manual.pdf PTID 3026 R1 T Clopay Torsion Spring Manual.pdf PTID 3026 R1 T Clopay Wood Manual.pdf PTID 3026 R1 T F1-3026R1 Statement of Revisions.odf PTID 3026 Ri T FPA ResiModel Info Rev07.pdf PTID 3026 R1 T RHlSW5-09-Rev03.pdf PTID 3026 R1 T RHiSW5-16-Rev03.pdf PTID 3026 R1 T WINDCODE(R) Supplements.pdf Created by Independent Third Party: 3026.2 W3-16: 73, 1500, 75, 190, 11 Steel Pan (min. 25 ga.) Double Car (9'2" to 16'0" h"://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsjfpmx6jjBWE... 7/11/2008 Florida Building Code Online Page 3 of 6 84A, 94, 42, 48, 55, 4RST, wide) WINDCODEO W3 Garage Door 6RST, 4RSF, 6RSF, 110R, 120 R Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +20/-21 2) For Use Outside the High Velocity Hurricane Zone 3026.3 W4-09: 4400, 4401, HDG, Double -skin Insulated. (exterior skin 27 ga. min.; HDGL, 4300, 4310, 4301, interior skin 27 ga. min.) Single -Car (up to 9'0" SP20, SE20, SF20, 66, 67, wide) WINDCODEO W4 Garage Door 68, H400, H401, H310, H300, H301 Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +28/-29 2) For Use Outside the High Velocity Hurricane Zone 3026.4 W4-09: 73, 1500, 75, 190, Steel Pan (min. 25 ga.) Single -Car (up to 84A, 94, 76, 42, 48, 55, 9'0"wide) WINDCODEO W4 Garage Door 4RST, 6RST, 4RSF, 6RSF, 2RST, 110R, 120R, H73, H500, H76, H94, H4ST, H6ST H2ST, H4SF, H6SF Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +25/-32 2) For Use Outside the High Velocity Hurricane Zone 3026.5 W4-16: 4400, 4401, HDG, Double -skin Insulated (exterior skin 27 ga. min.; HDGL, 4300, 4310, 4301, interior skin 27 ga. min.) Double Car (9'2" to SP20, SE20, SF20, 66, 67, 16'0" wide) WINDCODEO W4 Garage Door 68, H400, H401, H310, H300, H301 Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +25.5/-25.5 2) For Use Outside the High Velocity Hurricane Zone 3026.6 W4-16: 73, 1500, 75, 190, Steel Pan (min. 25 ga.) Double Car (9'2" to 16'0" 84A, 94, 42, 48, 55, 4RST, wide) WINDCODEO W4 Garage Door 6RST, 4RSF, 6RSF, 110R, 120R, H73, H500, H76, H94, H4ST, H6ST H2ST, H4SF, H6SF Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +24/-24.5 2) For Use Outside the High Velocity Hurricane Zone 3026.7 W4-16: C11, C12, C13, C21, Double Skin Insulated (exterior skin 27 ga. min.; C22, C23, HC11, HC12, HC13 interior skin 27ga. min.) with Overlay Double -Car (up to 16'0" wide) WINDCODEO W4-Garage Door Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: h"://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsjfpmx6jjBWE... 7/11/2008 Florida Building Code Online - - Page 4 of 6 Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +25/-25 2) For Use Outside the High Velocity Hurricane Zone 3026.8 W4-18: 4400, 4401, HDG, Double -skin Insulated (exterior skin 27 ga. min.; HDGL, 4300, 4310, 4301, interior skin 27 ga. min.) (16'2" to 18'0" wide) SP20, SE20, SF20, 66, 67, WINDCODE@ W4 Garage Door 68, H400, H401, H310, H300, H301 Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +25/-25 2) For Use Outside the High Velocity Hurricane Zone 3026.9 W4-18: 73, 1500, 75, 190, Steel Pan (min. 25 ga.) 16'2" to 18'0" wide 84A, 94, 42, 48, 55, 4RST, WINDCODE@ W4 Garage Door 6RST, 4RSF, 6RSF, 110R, 120R, H73, H500, H76, H94, H4ST, H6ST H2ST, H4SF, H6SF Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +25/-25 2) For Use Outside the High Velocity Hurricane Zone 3026.10 W5-09: 1000, 183,1001, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" 187, 52, P2GF, 12SR wide) WINDCODE@ W5 Garage Door Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +30/-32 2) For Use Outside the High Velocity Hurricane Zone 3Obtl�lw} 1N5`09 73, 1500, 75, 190, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" 84 4, 76, 42, 48, 55, wide) WINDCODE@ W5 Garage Door 4RST, 6RST, 2RST, 4RSF, 6RSF, 110R, 120R Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +30/-32 2) For Use Outside the High Velocity Hurricane Zone 3026.12 W5-09: C11, C12, C13, C21, Double Skin Insulated (exterior skin 27 ga. min.; C22, C23, C31, C32, C33, interior skin 27ga. min.) with Overlay Single -Car C34, C35, HC11, HC12, (up to 9'0" wide) WINDCODE@ W5 Garage Door HC13, HC31, HC32, HC33, HC34, HC35 Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +33/-37 2) For Use Outside the High Velocity Hurricane Zone 3026.13 W5-09: RH1S, RH2S, RH3S, Reserve Wood Single -Car (up to 9'0" wide) RH4S, RH5S, RH6S, RHiG, WINDCODE@ W5 Garage Door RH2G, RH3G, RH4G, RH5G, http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsjfpmx6jjBWE... 7/11/2008 Florida Building Code Online l - Page 5 of 6 RH6G, RR1S, RR2S, RR3S, RR4S, RR5S, RR6S, RC1S, RC2S, RMS, RC4S RC5S, RC6S Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +32/-36 2) For Use Outside the High Velocity Hurricane Zone 3026.14 W5-16-HY: 73, 1500, 751 Steel Pan (min. 25 ga.) Double Car (9'2" to 16'0" 190, 84A, 94, 4RST, 4RSF, wide) WINDCODE@ W5 Garage Door 6RST, 6RSF Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +32/-32 2) For Use Outside the High Velocity Hurricane Zone 3026.15 _][W5-16: 1000, 183, 1001, Steel Pan (min. 25 ga.) Double Car (9'2" to 16'0' 187, 52, P2GF, 128R wide) WINDCODE® W5 Garage Door Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +30/-30 2) For Use Outside the High Velocity Hurricane Zone 3026.16 W5-16: 73, 1500, 75, 190, Steel Pan (min. 25 ga.) Double Car (9'2" to 16'0" 84A, 94, 76, 42, 48, 55, wide) WINDCODE@ W5 Garage Door 4RST, 6RST, 4RSF, 6RSF, 2RST, 110R, 120R, H73, H500, H76, H94, H2ST, H4ST, H6ST, H4SF, H6SF Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +30/-30 2) For Use Outside the High Velocity Hurricane Zone 3026.17 W5-16: C11, C12, C13, C21, Double Skin Insulated (exterior skin 27 ga. min.; C22, C23, C31, C32, C33, interior skin 27ga. min.) with Overlay Double -Car C34, C35, HC11, HC12, (up to 16'0" wide) WINDCODE@ W5 Garage Door HC13, HC31, HC32, HC33, HC34, HC35 Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +30/-30 2) For Use Outside the High Velocity Hurricane Zone 3026.18 W5-16: RH1S, RH2S, RH3S, Reserve Wood (9'2" To 16'0" wide) WINDCODE@ RH4S, RH5S, RH6S, RH1G, W5 Garage Door RH2G, RH3G, RH4G, RH5G, RH6G Limits of Use (See Other) Installation Instructions. Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +30/-33.5 2) For http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsjfpmx6jjBWE... 7/11/2008 Florida Building Code Online .- Page 6 of 6 IUse Outside the High Velocity Hurricane Zone 11 3026.19 W6-09: 4400, 4401, HDG, Double -skin Insulated (exterior skin 27 ga. min.; HDGL, 4300, 4310, 4301, interior skin 27 ga. min.) Single -Car (up to 9'0" SP20, SE20, SF20, 66, 67, wide) WINDCODE@ W6 Garage Door 68, H400, H401, H310, H300, H301 Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1) Design Pressures: +37/-40 2) For Use Outside the High Velocity Hurricane Zone 3026.20 W6-09: 73, 75, 84A, 94, 42, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" 48, 4RST, 6RST, H73, H94, wide) WINDCODEO W6 Garage Door H4ST, H6ST, 110R, 120R Limits of Use (See Other) Installation Instructions Approved for use in HVHZ: Verified By: Approved for use outside HVHZ: Created by Independent Third Party: Impact Resistant: Evaluation Reports Design Pressure: +/- Created by Independent Third Party: Other: 1)Design Pressures: +38/-42 2) For Use Outside the High Velocity Hurricane Zone -._....---...---.. Go to Page ._.._.._........_.._. Page 1 / 2 BacEc text DCA Administration Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Fax (850) 414-8436 © 2000-2005 The State of Florida. All rights reserved. Copyright and Disclaimer Product Approval Accepts: kyVcri$3�n SncutcQ VER4FV* http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsjfpmx6jjBWE... 7/11/2008 TABLE 1609.6D An-111CTUPMT PARTnO I:n17 RIM nIMd: I4GIP1aT AMn FYPASIIRF_'nl MEAN ROOF HEIGHT EXPOSURE 15 1.00 1.21 1.47 ' 20 1.00 ' 129 .155 25 1.00 1.35 . 1.61 30 1.00 1.40 1.66 35. 1.05 1.45 1.70 • 40 1.09 1.49 1.74 45 1.12. 1.53 1.78 50 1.16 156 1.81 55 1.19 1.59 1.84 60 122 1.62 1.87 For SI: 1 foot = 304.8 mm. TABLE 1609.6E GARAGE DOOR WIND LOADS FOR A BUILDING WITH A• MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psi) EFFECTIVE WIND AREA Basic Wind Speed V (mph - 3 second gust) Width (R) HeigM (tt) 85 90 ' 100. 110 120 ' 130 140 150 Roof An e 0 -10 degr=" 8 -8 10.5 -11.9 .11.7 -13.3 14.5 46.4 17.5 -19.9 .20.9 -23.6 - 245 -27.7 ' 28.4' -32.2 32.6 -36.9 10 lO 10.1 • -11.4 11.4 -12.7 14.0 -15.7 17.0 -19.0 202 -22.7 23.7• -26.6 275 -30.8 31.6 -35.4 14 14 •10.0 -10.7 10.8 -12.0 133 -14.8 16.1 -17.9 192 -21.4 22.5 -25.1 26.1 -29.1 30.0 -33.4 Roof Angle > 10 9 7 11A -12.9 12.8 ' -145 15.8 -17.9 .19.1 -21.61 22.8 -25.8 26.7 -729.7 31.0 -35.1 35.6 -402 16 • 7 ': 10.9 -.122 123 -13.7 15.2 -16.9 18.3 -20.4 21.8 -243 25.6 - '-33.1 34.1 -38.0 For SL• 1 Square foot = 0.929 Sgm,1 mph = 0.447 mis, l psf = 47.88 N/sgnL 1. For effecctive areas or wind speeds between those given above the load may be interpolated, otherwise use the load associated with the lower effective area 2. Table values shall be adjusted for height and exposure by multiplying by adjlisnnent coefficients in Table 1606.2D. 3. Plus and minus signs signify pressures acting toward and away from the building surfaces. 4. Negative pressures assume door. has 2 feet of width in building's end zone. 1609.6.5.t' Garage doors. Pressures from Table 1609.6E. for wind loading actions on garage doors .for buildings designed as enclosed shall be permitted.