Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSOFFICE USE ONLY: Date:ib . =Recei.7pt#�; 7 Permit #. ?y7 i ALL INFO MUST BE COMPLETE & FILLED IN TO BE ACCEPTED /0 ,., St. Lucie County Building and Zoning Val u ® 2300 Virginia Avenue ������® a Ft. Pierce, FL 34982-5652 772-462-1553 BY APPLICATION FOR ALUMINUM. STRUCTURES PERMIT PROJECT INFORMATION 1. LOCATION/SITE ADDRESS: k K / 2. S/D NAME: am PLAN NAME: '—s cC�sn ycl' L.Y 3. PROPERTY TAX ID #: 4. LEGAL DESCRIPTION (attach extra sheets if necessary): L v 2 5. PLAT 6. PAGE 7. BLOCK 8. LOT BOOK NO. NO. NO. 9. PARCEL SIZE: ACRES/SQ FT. ;fg�7 LOT DIMENSIONS _ to,, ao (pa �C 10 0 . 10. SETBACKS (ACTUAL) FRONT: 40L BACK: z fr RIGHT SIDE: % LEFT SIDE. Z T — 11. TYPE OF STRUCTURE (CHECK AU APPROPRIATE BOXES FOR EACH AND EVERY TYPE OF STRUCTURE) TYPE OF CONSTRUCTION N=New A= Addition R = Rebuild SG = Slab on Grade SR = Raised Slab WD = Wood Deck DIMENSIONS SQUARE FEET OF CONSTRUCTION ❑ SCREEN ROOM . ❑ NEW ❑ EXISTING X CARPORT/PATIO ROOF 'Z SCE ❑ NEW ❑ NEW X ❑ EXISTING EXISTING 1-2— X 4+2Z X 5p ❑ HAIWABLE GLASS ROOM ❑ SUNROOM _ ❑ NEW ❑ EXISTING X ❑ SHED ❑ NEW ❑ EXISTING X ❑ POOL ENCLOSURE ❑ NEW ❑ EXISTING X ❑ M H ROOF OVER ❑ NEW ❑ EXISTING X ❑ POOL FENCE Linear feet, ROOF SYSTEM OVER EXISTING ACCESSORY. STRUCTURE ❑ NEW ❑ EXISTING X ❑ OTHER: ❑ NEW ❑ EXISTING X TOTAL SQUARE FOOTAGE OF CONSTRUCTION 12. f©00.00 The value of construction is used to determine the amount of permit fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value ofrconstruction if it is demonstrated that the submitted figures are not consistent with similar types of construction activities. If the value is $2500 or more, a RECORDED Notice of Commencement must be submitted PRIOR TO FIRST INSPECTION. SLCCDV Form No.: 001-02 Rev. 2119107 d OWNER INFORMATION NAME: A� rz- � \ ADDRESS: ��� ZIP L=!�Ac\s- Zd CITY: STATE: PHONE (DAYTEVIE): (l72) 7 93'3 S S email: FILL IN NAME AND ADDRESS BELOW IF THE FEE SIMPLE TITLEHOLDER (PROPERTY OWNER) IS DIFFERENT FROM THE OWNER LISTED ABOVE: FEE SIMPLE TITLEHOLDER: ADDRESS: CITY: STATE: ZIP PHONE (DAYTEVIE): (_) CONTRACTOR INFORMATION STATE OF FLORIDA REG./CERT #: CSC, 1 ZS 6'5"I ST. LUCIE COUNTY CERT #: -2- Z i LA �Q �c�l C%(--)v—\-Va`G_C4, BUSINESS NAME: %C QUALIFIER'S NAME: C. �.., e� , CA P Y-zS ADDRESS: cc STATE: 28 __3 1,3C I C,� CITY: o •pel�k��, cv�,.kw�����Q PHONE (DAYTEVIE): ( ) u4y nC12-�%Z FAX NO. email: _ i ARCHITECT/ENGINEER:vJ.S�► . C� \ E' �� �' PHONE (DAYTIME): (S `l 2Z " 2_62­1 NOTE: IF APPLICABLE, SUBCONTRACTOR AGREEMENTS MUST BE ATTACHED TO•APPLICATION FOR ROOFING, ELECTRIC, PLUMBING, AND HVAC ZONING REQUIREMENTS All such structures will be subject to the requirements of the ST. LUCIE COUNTY LAND DEVELOPMENT CODE. 191 2 scaled plot plans showing lot size, dimensions of existing host structure, -and proposed aluminum addition. All setbacks including front, side, rear and distance between adjacent property structures in MH Parks shall be indicated on the plot plan. Q.-,2 sets of color photos for all storm damaged areas to be reconstructed. One picture must include house address number for inspection verification. ( not required for construction unrelated to storms) till7 y' L � rim. ZONING _ .. ,. .:..' ....... ... ......-_ .:.... _ --.. . rn.: .�.,. .. },..+ d .. SECTION TOWNSHIP RANGE D � MAP NO. Additional Yes ZONING Lj. R LAND USE LOT CVG % Permits no D V 6 t ! REPORT CODE n %� BIMS FEE MISC FEES TOTAL FEES (� $ 1 111 V.. .. .. ,� Olt.. .orrvw _.._ .. .... -y ... REVIEWS ZONING ZONING PLANS MISC. VEGETATION VALUE OF CONSTRUCTION REVIEWED BY EXAMINER USING ICC TABLE DATE yJ COMPLETE INITIALS PLAN REVIEW SPECIFICATION CHECKLIST PLEASE PROVIDE ONE OF THE FOLLOWING: 1QP2 Sets of Detailed Plans: Dated, Signed & Sealed by an Engineer or Architect holding a Florida State professional license. ❑ 2 Sets of Detailed Plans: Designed in accordance with the AAF Guide To Aluminum Construction in High Wind Areas. (I) ANY PLANS SUBMITTED WITHOUT COMPLYING WITH THE FOLLOWING SHALL BE RETURNED WITHOUT APPROVAL. ALL PLANS MUST BE IN INK AND ANY NOTATIONS IN PENCIL WILL NOT BE CONSIDERED A PART OF A SUBMISSION. • All plans must be legible and must be designed in Architect's Scale on pages which are 81/2" x 11" or larger. • All relevant tables & details, if using the AAF Guide, must be properly highlighted and must match design checklists & drawings. • The plan view must include all dimensions; the location of the host structure and all materials must be sized and identified thereon. • All elevations must be shown, including 4`s wall detail, dimensions and all material must be sized and identified. • All primary and secondary carrier beams, spans, spacing, gauges must be shown [Example: 2" x 8" x .072"]. • All methods of fastening or other details which are relevant to the design must be identified on the Plans. • All upright column heights, sizes, spacing and gauges must be shown as follows: [Example: 3" x 3" x .050"]. • All chair -rails, roof purlins, girts, channels, knee -bracing, k-bracing, cable bracing or any other required component must be sized and identified. • All ridge beams and super gutter or fascia attachments must be identified. • All roof pans or composite panels, with gauges and spans, must be sized and identified. • All footing, slab and ISO pier designs must be on the plans, per the Architect / Engineer's plans & specifications. • All light metal alloys which are utilized shall be designed in conformity with the Florida Building Code of 2004, Chapter 20, including 2006 revisions. • Barrier railings, if utilized, shall have all materials, fasteners and height specified and shall have self -closing, self catching gates with picket spacing. (II) SITE CONSTRUCTED SHEDS, HAVING ANY ALUMINUM COMPONENT, SHALL MEET ALL OF THE ABOVE REQUIREMENTS AND THE FOLLOWING ADDITIONAL ITEMS: (A) 2 copies of the current product approval [i.e. N.O.A. or State of Florida approval] with the proposed "opening" or cladding component highlighted and with fasteners and design pressures, per FBC 1714, clearly identified. (B) 2 electric schematics, in accordance with the N.E.C., if applicable. (C) Design pressures, per Table R 301.2 (2), identified on the openings of all Plans. (III) HABITABLE ROOMS/ADDITIONS DESIGNS SHALL MEET ALL OF THE ABOVE REQUIREMENTS, EXCEPT AAMA SPECIFICATIONS, AND CHAPTER 13 OF THE FLORIDA BUILDING CODE. (IV) SUNROOMS (as defined in R202 or FBC1202.1) MAY BE CONSTRUCTED; SO LONG AS THEY MEET ­ALL OF'TgIE ABOVE REQUIREMENTS -AND MUST BE IN STRICT COMPLIANCE WITH_AAMA/NPEA/NSA2100.02`AND,MEET'THE . FOLLOWING ADDITIONAL ITEMS (1) The designer or engineer. will state on,all Plans, which Category of Design [3.1.2] will be�used, inclusive of the definition.. (2) If designing a Category4.or Category 5-structure, as defined in the current Edition of 3.L.2,4.and 3.1.2.5, proper:energy calculations and long form_ equipment sizing calculations shall be required pursuant to Chapter 13 of the current State of Florida --Building Code. (V) MOBILE HOMES (FAC 15C-2.0081 - FAC 15C-2.0072): ALL STRUCTURES ADJACENT TO OR NEW ROOF SYSTEMS (Pan or Composite) OVER EXISTING ADJACENT STRUCTURES TO A MOBILE HOME SHALL REQUIRE: (a) A 4`a wall or a current, signed original manufacturer's attachment approval letter which includes the model number, serial number and current owner's name and street address. (b) That the complete guide to H.U.D. specifications be strictly adhered to. (c) A Certified Florida Engineer may design the manner of attachment of the proposed structure to the host house but shall assume full responsibility for both structures' integrity by site specific documentation. CERTIMCA'1101N: This application is hereby made in order to obtain a permit to do the work and installations as indicated, and to obtain a certificate of capacity, if applicable, for the permitted work. NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE TO APPLICANT: IN THE EVENT IT IS NOT YOUR RIGHT TITLE OR INTEREST THAT IS SUBJECT TO ATTACHMENT, THE APPLICANT DOES HEREBY MAKE A GOOD FAITH PROMISE TO DELIVER A COPY OF THE ATTACHED CONSTRUCTION LIEN LAW NOTICE TO THE PERSON WHOSE PROPERTY IS SUBJECT TO ATTACHMENT, AND DOES SO AS A CONDITION PRECEDENT TO THIS PERMIT 1. If utilizing the AAF Guide to Aluminum Construction in High Wind Zones, I the Contractor/Owner Builder hereby certify that the components being used, fasteners type and fastening pattern meet all the requirements for the designated wind zones established -by the county and take full responsibility for complying with the submitted design of the structure being permitted. 2. I further certify that all the foregoing information is accurate, that no work or installation has commenced prior to the issuance of a permit and that all work shall be performed in compliance with all applicable laws regulating construction and zoning in this jurisdiction. I understand that separate permits may be required for ELECTRICAL, and HVAC, etc., not otherwise included with this building permit application. 3. I , the Contractor / Owner Builder, have verified that the existing foundation meets the requirements of the Engineer of Record and is in adequate condition to withstand the uplift and weight of the aluminum structure and said structure will not exceed the footprint of -the structure that was in existence prior to removal by the storms. OWNER/CONTRACTOR SIGNATURE STATE OF FLORIDA COUNTY OF 5�A - L._. UGA'P_ The foregoing instrument was acknowledged before me this day of " C 20&�by .v. N e i 3er� who is personals._,_ know to me or who has produced .,as­w ULVItn-myiII11r,� KAL IUMBELY (SEAL) MY COMM SSRON D E548781 r' va EXPIRES: May4,2010 r'. Bonded Thru Notary Public Underwr ters IMPORTANT NOTICES: CONTRACTOR SIGNATURE STATE OF FLO A COUNTY OF The foregoing instrument was acknowledged before me this - day off, 20L&, by cLf� kC� who is ne_rco� nal 1po= to me or who has produced as identification. Signatdre'ef Notary (SEAL) ,'gN.L.To_ IQMBERLYMLE {{ , MY COMMISSION # OD 548781 $p `` Bonded, EXPIRES: S: May 4, 2010 t otery Public Undenvdters • TWO (2) SIGNATURES ARE REQUIRED. EACH SIGNATURE MUST BE NOTARIZED. IF APPLYING FOR THIS BUILDING PERMIT AS AN OWNER/BUILDER, THE OWNER MUST PERSONALLY APPEAR TO SIGN THIS APPLICATION IN THE OFFICE LISTED ON T]qE FRONT OF THE APPLICATION. • ALL SIGNATURES ON APPLICATION SUBMITTED SHALL BE ORIGINAL. COPIES, FAXES, OR STAMPED REPRODUCTIONS ARE PROHIBITED. • WHEN A PERMIT IS AVAILIBLE FOR ISSUANCE BUT IS NOT PICKED UP WITHIN THIRTY (30) DAYS AFTER NOTIFICATION OF AVAILMILITY, IT WILL BE VOIDED. IF THE APPLICATION IS RESUBMITTED, AN ADDITIONAL FEE WILL BE CHARGED. al LLJUit Qu PAGE 03 OR01- na� Public Worlm Department Code Compliance Division 2300 Virginia Avenue Ft -Pierce, FL 34982-5652 PERM T RENEWAL REQUEST ADDRESS (?, &_41Z JrA c. Iat FEWT No.: 0 RLQUESTNO THAT THE ABOVE PERMIT IS REMWED FOP, ST10HTEEN MONTHS- I UNDEMTAND THAT 1 MUST SCHEDULE 'A.ND PASS - AL' L, ILEQUMW INSPEC'i°tONS FOR TM PERMIT TO HE FTNAIED, pUpTj_M& T UNDERSTAND THAT THIS IS A ONE TUB RENEWAL AND THE Pmw SkIA L EXPIRE SHOULD I NOT RECET'V,S A PASSMO AdSPI;MONY DURING ANy SIX MONTH PERIOD DURING THE RENEWAL. F OD. Owner/Build= or Contmetor Signature Date'. . STATE OF FLORIDA COUNTY OP Li.,L Sworn to end subs:mbod be£orz me this day of �! L r . 2a0 , by hah 6,nrd &rC: . Who is personally known _. orwho has Mduued �(� �+•i,�„�xA � I�a'C2,_ag identlfsratipi►. Notary Public, State of Florida Signatm omotary:- �, r 0 colpmission No,:im LAMANIVA N DW13Vcr27 �t110kOR anicz USE ONLY:w,p,,,m,�co 0NEWAL FEE: Qp�1 I�T�SPE_Cl'IQN_S C-- X . PERMIT FEE ($ '% `-)' ) m S. `ys, TOTAL [NSPECnONS £/£ d U529WIL << 05:£� 92-90-6002 EDWIN M. FRY, Jr., CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 3232973 c--,)OK 2995 PAGE 1586, Recorded. 07/16/-, A at 02:44 PM AlMMMCMDM-=nMNM & I PEkNMMBMML NOTICE OF COMMENCEMENT The undamped hereby given nobc; that mVmven= will be ft& toftrtaht real PC". and in swMb= with Chapter 713. Florida StRIM the following information is provided in the Notke cfCommartoemcM 1. andsts addzmffavw1")TAxmuoxum=- -jWfj-50 11-701 OW/9 Cr k- -or- t e cxA-x Ack evt -z-(n Na%4 V s 19, Z- "-,4 L- 3. & Name ndod&moffwdmp6tidAdA,(if cthwtam Onaa) 4. 3YVC)14 $, BMWrrSNAM14ADDUMANDPBMNUMMANDRONDAMDM": 6 LUMMSMOMA)MI)MMANDIMMMICNIJIMM 7. Parsom within the State ofFlonditticsipwated by Owncruponwh=nDticasorotherdoeumattsmay besmodasprovided by Section 713.13 (1) (a) 7.. Florida Statutes: NAM, ADORMAND PROM M13113t: S. In addition to hunselforbuscK Ownerdesipstes to following to receive ftaM ofthe Liew?s Notice as provided in section 713.13 (1) 01 Florida Statutes: MAMADDRMANDMOPMMOGM 9. BViradon date of notice ofournmeaccutent (the expiration date is I yea from the date ofmomft tales a diffooM date is specified):--2CL_ 'StatoofFlorids CTmV of Palm Beach .1..IW9.d' 6 moth dayof-QYAP- 20 0? By C�JA - a .For ( /(7e�e� of parry oa behalf of whom itatrttmeot was e:mcttted) KNEMALE (Signwtmeo Puhu) WOOMBSIMMUMI EMMES.-MMY4,2DID Under 04 69 the facts in it am true to the beg ofmy bowlaip and By ST E OF F 0 IDA ST. ME OU TY TH'I ST Eff I IFYT THI$ESA TR OP OP OFTHE ORI I Y, J - LE R K Date: 0 OA U TEN File Edit View Tools Window Help ry I� �❑ '�' a Q Q r R ry n i 1 b.3S3M E 8 xr `© NC are ! �$ Wednesday, Jul 16, 2008 02:08 PM Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stiucieco.gov/ce Date: 16 July 2008 Job Address: I MARGARITA Ln Received By: humphreya Paid With: CK Paid By: DOLPHIN CONTRACTING INC Building Receipt Receipt M 0000064297 'ermit Number: SLC- 0807-0288 Amount: $50.00 �redit Card Number: Check Number: 1604 Sign: By Date (r) -2�896-?3S3 SPANISH LAKES I LAYOUTNAP—P ROVED G BRA LAITY I MIN. SETBACK REG. FRONT SIDES I c:; CNR SIDESc;D REAR 15 ZNG. TECH. LJ hl F- m m F— m D O z 0D 4TH WALL, NO STRUCTURAL ATTACHMENTS TO EXIST. MOBILE HOME (TYP.). FLASHING ONLY. - - - - - - - ----- I 8lB CARRY BEAM-------- --------- I o I 3X3 COLUMN m I (TYP OF 10) „ 00 p I"-----------� I z �} 3"X12"X.032" N ALUM. PAN ROOF I �a EXISTING z z i i SHED BELOW o I I _ _ _ _ _ _ = _ _ _ _ 7LB CARRY -BEAM - - - _ = = = = - = - - - - - _ _ _ _ �_ _ _ = = = = = = = = �I- 4 4. O.H. 40'-3" fi PAN ROOF ICI 7LB CARRY BEAM SCREWS (TYP) 4(3) #14 TEK SCREWS EACH SIDE (TYP) (3) #14 TEK Ile - SCREWS 2"X2"Xt/8" (TYP) U-CHANNEL 3X3 COLUMN (3) #14 TEK SCREWS _ EACH SIDE (TYP) 2"X2"X1/8' U-CHANNEL KNEE BRACE -DETAIL NTS SEE KNEE BRACE % DETAIL 1 o n z �N 7LB CARRY BEAM �OPEN `OPEN o U X `OPEN o U X EXISTING SHED o U X M M � M EX 40'-3" W/ (SI ST LUCIE COUNTY DESIGN CERTIFICATION CODE EDITION: FBC 2004 EDITION W/2007 AMENDMENTS OCCUPANCY: SINGLE FAMILY DWELLING — PATIO ROOF BUILDING DESIGNED AS: OPEN STRUCTURE BUILDING HEIGHT < 60 FEET MEAN ROOF HEIGHT: 8'-10" IMPORTANCE FACTOR: 0.77 BASIC -WIND VELOCITY PRESSURES: WIND SPEED: 140 MPH (3 sEcoNo cus0 BASIC WIND VELOCITY PRESSURES: 30 PSF ROOF ROOF DEAD LOAD (►crmaL Dm m&D usn To REsw uniFT REAcnoNs): 2 PSF SOIL BEARING CAPACITY: 2500 PSF REVIEWED FOR SHEAR WALL REQUIREMENTS: YES IMPACT PROTECTION SPECIFIED: NO FRONT ELEVATION RATIONAL ANALYSIS CALCULATION PER FBC 2004 W/2007 AMENDMENTS FOR EXISTING FOUNDATION qz = 17 PSF (PER TABLE 2002.4) 17 PSF — 2 PSF (DEAD LOAD) = 15 PSF WIND UPLIFT = 15 X 41 X 6 = 3,690 LB APPLY SAFETY FACTOR = 1.67 X 3,690 = 6,162 LB WEIGHT OF 4" CONC. SLAB = 144 X .333 X .40.2 X 6 = 11,566 LB TOTAL WEIGHT = 11,566 > 6.162 I ....OK EXIST. SLAB & NO FOOTING IS ADEQUATE NOTE: IF THERE IS AN EXIST. POOL, A MIN. OF 36" MUST EXIST. B/T POOL AND EDGE OF SLAB. I iiiiiiiiiii3 HOME / co W z o W N W cn 8'-5" z O W J W CD BUILDING DIVISION REVIEWED FOR O IANCE REVIEWE B DATE S D PERMIT' MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE sr. 4" CONC. SLAB NO FOOTING E RATIONAL ANALYSIS) THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL ABIyE CODES. 3X3 COL.--, (1) 3/8"X2" LONG - TAPCON EACH ANGLE EXISTING CONC. ?— S �� (2) 1/4- THRU-BOLTS THRU EACH ANGLE AND POST �2"X2"X1/8" ANGLE EXISTING FASTENER r . ANCHORING DETAIL NTS Sv N H z w f z w f Q 0 0 N p m w ° Lu o� o U) N IL U X In W lL w m 2 � H CL o 0 1L zZ U O m o Z w Q N �a � in w z N 0 w ;J75 H o o o 00 (n 0 II of a \ - i= 000 00 m0 � \ m o 0 o It w z m Lij -1 3 0 .) O U V) Z PAV i� d (0 0) I r N d L0 v x L2 r N 0 N I r N t` 'd m rn a� c 0 s or RATI❑NAL ANALYSIS ❑N EXISTING STRUCTURE tvror can TTV TO SUPPORT ADDITIONAL ALUM. PAN LOADS) MAXIMUM OVERHANG WIDTH ALLOWABLE FOR GIVEN TRUSS OR RAFTER SIZE (IN FEET) ALUM. PAN RAFTER OR TRUSS SIZE FOR ROOF SLOPES UNDER 2 1/2 IN 12 RAFTER OR TRUSS SIZE FOR ROOF SLOPES ABOVE 2 1/2 IN 12 SPAN 2X4 2X6 2X8 2X10 2X12 2X4 2X6 2X8 2X10 2X12 (IN FEET) MAX. OVERHANG WIDTH MAX. OVERHANG WIDTH 0-6 2.2 1 4.0 1 5.7 1 7.7 9.8 2.1 3.7 5.3 7.2 9.1 7 1 2.0 3.7 1 5.4 1 7.4 9.5 2.0 3.5 51 6.9 8.8 8 1.9 3.5 5.1 7.1 9.2 1.8 3.3 4.8 6.6 8.5 9 1.7 3.3 4.9 6.8 8.9 1.7 3.1 4.6 6.4 8.3 10 1.6 3.1 4.6 6.5 8.6 1.6 3.0 4.4 6.2 8.0 11 1.5 2.9 4.4 6.3 8.3 1.5 2.8 4.2 5.9 7.8 12 1.4 2.8 4.2 6.0 8.0 1.4 2.7 4.0 5.7 7.6 13 1.3 2.6 4.0 5.8 7.8 1.3 2.5 3.9 5.5 7.3 14 1.2 2.5 3.8 5.6 7.5 1.2 2.4 3.7 5.3 71 15 1.2 2.4 3.7 5.4 7.3 LI 2.3 3.6 5.2 6.9 16 1.1 2.4 3.6 5.3 7.2 I.0 2.2 3.5 5.1 6.8 17 1.0 2.3 3.5 5.2 7.1 1.0 2.1 3.4 5.0 6.7 ....w ....,.... .,..._ - -- - - - ' _UAG ---- -- - - - -- A OR RAFTER ENO V/ A NIN. OF ONE L/4' % 3 1/2' LAG SCREW PER TRUSS OR RAFTER END 2. IF ROOF OVERHANG IS NOT COMMON, A SPECIFIC CALCULATION WILL BE REQUIRED BY THE ENGINEER OF RECORD 3. CONNECTION DIRECTLY TD CONCRETE TIE BEAN W/ SOLID CBS WALL BELOW WAS CALCULATED TO BE SAFE IN ALL CASES EXIST'G. HOUSE 1 #1 #4 THRU EA. DETAIL 1 1 #4 /INTO WO. EA, II I I DETAIL 2 v 24-0' PLAN GABLE SCREEN RM. .AL. VALANCE OPT::'. •SCREEN f COLS KICK -PI AL. FLASHING . W/ 3# 1 EA ­ a, 2x3 �, �I e' C.C. J #12 C3 m 24' DT , #12 12.000' @ 16' C.C. CONC. OR @ 16, C.C. 2X4 STUD) #2 EA. PAN C 2x3 W/ 3-#2 EA. 3XIP PAN PAN HOUSE WALL C❑NN. COLUMN 202 202 8-#2 (TYP.) INTERMEDIATE COL. FOR SCREEN ROOM #14 TEK SCREWS EA. - SIDE BM. VILL DETERMINE NUMBER. MIN. 3 202 ANCHOR EA. PAN TO BM. V/ 3 #I'S CARRY BEAM 2'X2'XI/8' THK. COL. RECEIVING TO COL W, CARRY BM TO ALUM. PAN TO BM. "'2-3/8' THRU BOLTS %' W/ WASHERS & NUTS j� `BEAM E HOME) "SIDE) W/ 2 - #4 - (W/2 - #7 EA. CLIP iSCIA) z Q O_ V) (U z \ a. rn - z AL. FL'G, a z o_ y N MIN. 2' FASCIA-1 2 ) BM. C❑NN. AT FASCIA (" 0 3-#2 W/V 3-#2W/I' WASHER 3 / PAN WASHER 3 / PAN 1X2 #2 (1-1/2' LONG) #5 CLIP ANGEL 11' C.C. (TYP.) u W/3 - #2 EA. FACE #5 CLIP ANGLE W/3 - #2 EA. FACE L. GREATER THAN 6' AND A PAN SPAN OF 1FOR COL. SPAN 6' OR LESS AND LESS. (SEE BM TABLE FOR ❑R CLEAR A CLEAR PAN SPAN OF 12' OR S. LESS. (SEE BM TABLE FOR CLEAR PAN SPANS GREATER THHANAN 12') PAN SPANS GREATER THAN 12') DETAIL B-B #2 @ 12' C.C./PAN T&B C 2x3 W/ 3-#2 EA. TRUSS 3X12 PAN PAN BOXED END #7 TO EA EXIST. G TRUSS 2' MIN. FASCIA #3 @ FROM CHANNEL AND @ 12 CONC.ixi::.i::;,4�i`i. O.C. MAX. TO FASCIA TO 2 x NOTE, FASCIA MAYBE BUILT UP BY W D/ LAGGING NE 1' MEM. TO ➢L I�#fk�s 2-1/4' x 3-1/2' LAGS/TRUSS OR RAFTER FASCIA C❑TUTU. ..:.:_.. z Q O_ (U w q J O q J w U � U ¢ to w - w f W THESE ARE St REQUII MAY 81 HOUSE PAN :a=s.-,��ruiv�, `•�'':' A:yp CON(. WALL A A. Z.' P`LI4TJGE 0 1 TW - /4'X2-1/4' LON/ BEAM 'X 'X BEARING WALL COLUMN TAPCON ANCHC]R 2 2 1 /8' CLIP ANGLE A S �E M X. PA PAN T X R CLIP IN ❑ E TG THRU - EA. SIDE W/2 #4 ❑R - CLIP TO BM. 3 #1 EA. PER ENGINEER (SHT. 'C') 7 CON(. WALL. (TWO EA CLIP. 4/BM) - USE 3 #4'S FOR "> 7LB BMS OR LARGER E BM TO HOUSE C❑TUTU, ELEVATI❑N A CAR PORT 3444-H36 ALUMINUM ALLOY 3' x 12' x .024' ALUM. PAN (MAX, SPAN = 10'-0') ALUM. PAN DETAIL SHEET1 o ' 0 32' 0 (`7 +f L. KICK PL. OPT. / USE 1X2 TOP ATT. K.P. 1 #1 @ 8' O.C. 3444-H36 ALUMINUM'ALLOY 3' x 12' x .032' ALUM. PAN"'•''`>>;r `"` (MAX. SPAN = 11'-6') )ER F RC, 2004 EDITION W/ 2007 A Ll B OL, SCREEN COF BEARING WALL 8'-0' MAX. 202 (SCREEN RMS ONLY ELEVATI❑N SCREEN ROOM 7-02 STA B--j GUTTER W/#6 @ 12' C.C,aa TOP & BOT. 3/PAZ I #10 X 1 1/2 #8 @ el C.C. PAN ANCHOR EA. PAN TO BM. W/ 3 #1'S 1 Fm COL. -BOTTOM `-2-3/ THRU-BOL S`fI❑N B-B SECTI❑N A -A L :::;(SCREEN ROOM) (CARPORT) t2 @ 8'-k SITE SPECIFIC DRAWINGS FOR REQUIRED BEAM AND COLUMN SIZES. VX2' 302 OR 202 i 202 :❑TUTU. 2 -#2 2 -#2 R2 X 1 1/2' LONG a, @ 16, Q.C. N CORNER COL. UII CORNER C❑L. f MAX. COL. HGT. PER TABLE (SHT. 'C') FASTENING SCHEDULE #1 - #14 TEK SCREW/HEX HEAD #2 - #12 S.M,S./ HEX HD. #3 - 1/4' X 2 1/4' TAPC❑N ANC ❑ H R #4 - 1/4' BOLTS/WASHER/NUT #5 - CLIP ANGLE„125' MIN. THICKNESS #6 - #8 X 1' S.M,S./HEX HD, #7 - 1/4' X 3' LAG #8 - 1/4' LAG)(, WITH 1' WASHER #9 - #10 X 1 1/2' S.M.S,/HEX HD. #12 - CLIP ANGLE, 3/32' MIN.THICKNESS (LAG BOLT LENGTH TO BE 1' LONGER NER COL. THAN ALUMINUM PANEL THICKNESS CU �D w Cl (U t0 > c DATE m o � � M I 7 1 F- n z o ci C/) 1--i L o H - N J SCALEI N.T.S. . o � a) r` N a SHEE E C:) WJ Zw - :3 •- 0 o v h ~P=0 in Q Z < `J T. TARNOWSKI, P.. F-' Z z cnrl < z a STRUCTURAL ENGINEER - FIA. UC. 0050662 W w Q.. IL 0 040' Ri 040' 0 044' ci 1.0' in ' 7YP. TYP. ni TYP. In TYP. -- cu u-i055- -1 ,1N-- Iri .055' I, I. TYP. 4 1X2 1X3 202 GUTTER E ER FACIA HE AM TYPE 4LB t< .100 t e .046 t= '� jo #14 TEK SCREW S FOR 7LB OR LARGER OR #10 S.M.S. FOR 6LB OR SMALLER 2 18' C.C. TOP $ BOT. o : ,072 a C; R SLH 116 .050 6LB .050 7LB .120 .055 8LB 224 .072 9LB .224 .072 9LBH .306 .082 IOLB .389 1 .092 4LB,5L$ 3.0' 6LB 7LB 8LB,9LB,9LBH 3X3X0.072 Z- 10LB LAP BEAM (303) C❑L.�_SEE COLUMN ANCH❑RING DETAIL PAVERS OR TILES OPTIONAL 3O FR EDG B TT (MINE.) "LI 12'X8' FTG. W/1-#5 STRIP FTG. DETAIL W/ PAVER OR TILE 11I 12'X 8' FTG. IS MINIMUM FOOTING SIZE. REFER TO SITE SPECIFIC PLANS AND STRIP FTG. SCHED. FOR ANY ADDITIONAL REQUIREMENTS. MIN FOOTING SIZES SHOWN APPLY TO NEW .FOOTING'S ONLY. FOR EXIST. FOOTING'S SEE COLUMN COL FINISH GRADE 3' FROM T❑ BOLT SODDED READ. FOR EROSION PR TECTION ❑ I 1- 3' 2' MIN•* COVER NOTE, THIS DETAIL IS AI{ AND MUST BE ACCPP1AI SPECIFIC CALCUI;A;T# NOTE, APPLI WIDE CLIP COL. 0 0 0 O50' 6 4 In 2X3X0.050 2X4X0,050 2X5X0.050 EXPOSED 5.094' 1 Incu CU /2' 1' 0.5 2X3X0.070 D❑IAMB FOR COLUMNS5'D OR GREATER ADDITIONAL 2'X2'X2')a OF ANGLE EA. SIDE INS, 1k31 OF COL. W/..-J::=; X 1 ,,(.,3,.,.., _12 S.M.S. iro 2 1/2' TO CONC..>$<`.�` .,.xsz,iz_: 4,0' o TYP. o 0 .125' .050' T YP. 2X2 2.0, 2.0' C 2X2 3X3 C 2X3 4X4 2X5 3X2 4 : 2'X2'X3' LONG X 1/8' >_ t ANGLE N EA. SIDE OF COL. W/ (6) #12 X V LG. S,M.S. TO COL. & (1)- O ' 1/2' X 4' LG. EXPANSION �.. BOLT (WEDGE ANCHOR) c, O �p O •• _ ri SE<PLANS AND ALL PROPOSE-1 V ECT TO ANY CONRECTI ." RE b U1RED BY FIELD INSPECTORS W'"BdlI;IECESSARY IN ORDER TO - COMPLY WITH pLL APPLiCADLi< G( 1 #&'T❑ COL. (1 YP5 1/2' -X 4' LG. EXPANSION BOOT -<WEDGE ANCHOR) TO CONC. (TYP.) 2 PER COL. 1/4' TAPCON e 18' O.C. 43 ELSEWHERE QM%RTILES qW FTG. 44 %il •r - NT V F c R❑ ELE ATI❑W 3' FROM EDGE (MIN.) T❑ BOLT I - ::;jai:}�- - • 3' 1 - NOTE A LES' ARE NOT REQ'D. FOR 202 D❑❑R% JAMB COLS. a u W: R T MN T THE CONCRETE A, 'X ' ALL ANGLES SECURING HE�COLU 0 E ❑ ETE TO BE . IN. 2 2 X1 r... '_AR AA: -T T BE EXPANSION TYPE. (SEE - AN T N . LONG. 1/2' DI BOL S E ❑ GCS ❑ CO C DE 8' L' "C. LAB T W T EXPANSION BOLTS TO BE 'HLL I K IK BOLT II' SYSTEMAIR EQUA EX I L X 0/ W.W.M. 6-1 10 ...:. W/ - 'XB' FTG. 1 #S E F / X / TAPCON MAY E- USE IN LIEU ❑ L 2 EXPANSION BOLT-- 1 2B D TAPC❑S ARE SLMPSON 'TITEN' OR EQUAL - ETO R T VER ❑ ILE SEE GENERAL NOTES 2& FOR D 4 R ADDITIONAL REQUIREMENTS F x - lo/ o W.W.M. LIEU ❑ 6 6 1 .. GENERA °N' NT �rt. L-y � E��"�'�:.<.>.>.,: ` .:......... THIS STRUCTURE HAS 'BEEN DESIGNED & TESTED I �<❑RDANCE"�. EQUI7F SMa' �r F.B.0 2004 EDITION INCLUDING THE 2007 AM NDMtF� ,:r},. TIES F ACCORDANCE W/ LATEST ED. 0 T H E A LUM. CdN ti :: ALS❑ ST`'s:' Q_:': I IN .`Tf3RE. TO THE DESIGN CRITERIA [IF THE ASC E 7 02 a> SEE COLUMN ANCHORING DETAIL 4, - V40`M.P: COL WIND LOAD 4 :a - x.:. COLUMN SCHEDULE (FOR 1 .. 4 00 78' v TYP. 1 5.25' 1 ALUMINUM ROOFS) 064' t125' o -3 L 2X2 1 H Ul V J M A. UULUMII nl LUM 1 � UR + DLL L .iFF#.Cd4>: C❑LUMN TYPE: 3X3X.090 La Alt, ' �>t�:.. s�`<�%<;';�.>:Atti�s;'';i \ Ji•.. M :': V AM #`"% l DCMM LU J> - - ?H:;;<.. K - L.s I l.sz COL. SPACING 4 5 6 7 8 9 15 16 17 18 19 20 4 21.3 19.1 17.4 16.1 15.1 .0-it: 13.5 3�9<�`s: 11.8 11:4"`" 11.0 10.7 10.3 10.1 9.8 9.5 5 19.1 17.1 15.6 14.4 13.5:; :tf ":» '%12.1 1$ ? i ::i: ' ':: 10.2 9.8 9.5 9.2 9.0 8.7 8.5 6 17,4 15.6 14.2 13.2 12:1r f3&-1 ' >:' } 0 10.5' ' 1Qi •%:<%.. 9.3 9.0 8.7 8.4 8.2 8.0 7.8 7 16.1 14.4 13.2 12.2 11 .4 {.: '.. ?1 :1'`' ::'r' 0'' <-. 9 7 ' 9 +''i :`.: `' ... 8.6 8.3 8.1 7.8 7.6 7.4 7.2 8 I5.1 13.5 12.3 11.4 L 0.7 $'t 1t1, .. : 5: > . 9.....9.1 F: :7 % B ..., ';' 8.1 7.8 7.5 7.3 7.1 6.9 6.7 9 14.2 12.7 11.6 10.7 10.1 > :% ` : -iiB6 8.2 `%; t7.9 7.6 7.3- 7.1- 6.9 6.7 6.5 6.4 10 13.5 12.1 11.0 9.0 "` ?>. '' ::::; t`:::-.. 7.8 7.5 7 2 7.0 6.7 6.5 6.4 6.2 6.0 fORK 12.9 11.5 10.5::. s; .i %; £`.FX %%;:. 8.6 $''::`. z`T' '%'s ::7.4 7.1 6.9 6.6 6.4 6.2 6.1 5.9 5.7 � 12 12.3 11.0 :. ,^�:,..`7.1 6.8 6.6 6.4 6.2 6.0 5.8 5.6 5.5 14 11.4 10.2 7.6 7.2 ' fib'i!7:f: 6.6 6.3 6.1 5.9 5.7 5.5 5.4 5.2 5.1 16 10.7 9.5 :%F87; `6.1 ? s}`:: 7.1 6.7 Sf' 62 5.9 5.7 5.5 5.3 5.2 5.0 4.9 4.8 18 0.1 9.QY; 'i' : 7.6:ii:: 7'' 'j`s >` 7 -, 4 6.1 5.8 5.6 5.4 52 5.0 4.9 4.7 4.6 4.5 20 9.5 $ %'>i :r;$ $ +.7 ��sr "i: 7;s'i'` :. ' Ek<> 5.7 5.5 5.3 5.1 4.9 4.8 4.6 4.5 C++ f'fi]PEN WALLS WSOLI ALUMINUM / D ROOFS) GIVES:/f14?NN HEIGHT FOR GIVEN COLUMN SPACING AND BEAM LOAD C0,4z i YPEI 4X4`3* , . `; ;;: LOADING = 33 PSF AREA = 1.45 K = 1.5 I = 3.70 4 6 7 � 9 1 0 11 12 13 14 15 16 17 18 19 20 33 271 251 23 5 22.1 21.0 20.0 19 .2 18.4 17.6 17.1 16.6 16.1 15.7 15.2 14.9 2.5 21.0 19.8 18.H 1 7.9 7. 1 1 16.5 5. 1 9 15.3 14.9 14.4 14.0 13.6 13.3 24.3 9. 18.1 7. 1 1 16.4 15.7 15.0 4. 1 5 4. 1 0 13.6 13.2 1 2.8 L .4 2 12.1 }. 22 �?,BS �. ' 19.0 7. 1 8 16. 7 15.9 I5.1 4. 1 5 13.9 13.4 13.0 12.6 12.2 11.8 11.5 112 7 .4 1 1 11.1 10. 8 10 .5 .'' $48.1 16.7 15.7 13.4 12.8 12.3 11.8 11.4 11.1 10. 7 10.4 10.2 9.9 0 1 : ��� }; ::::i Et;$`s: : ��' 7. 1 1 _ 15.9 4. 1 9 14.0 13.3 3. 12. 7 12.1 11. 7 1 1.2 10.8 1 0.5 10.2 9.9 9.6 9.4 16.4 - 15.1 14.2 13.4 12.7 12.1 11.6 11.1 10.7 10.3 10.0 9.7 4 1 5.7 14.5 13.6 12.8 12.1 11.6 1L1 10.6 10.2 9.9 9.6 9.3 9.0 8.B 8.6 "�•�-15.9 14.5 13:4 12.6 1 1:8 112 10 7 9 ..2 8.. 8.6 8.4 8.1 7.9 1 < ...1 „ 6.6 14.9 13.6 12.6 11.7 Il.l 10.5 10.0 9. 9.0 92 8.9 8.6 8.3 8.1 7 .8 7. 6 7.4 <FBr sF .7 4. 1 0 12.8 11.8 11.1 10.4 9 .4 9.0 8. 7 8.4 � 8.1 7. 8 7. 6 7.4 7 .2 7.0 14.9 13.3 12.1 11.2 10.5 9.9 9.4 9.0 8 .6 8.2 7.9 7.7 7.4 7.2 7.0 6.8 6.6 '' ❑F THE S 'ALUM. ARE CONFORMS ='cr;.„,.,•- SCREEN WALL & SCREEN R04F=QADSBk + ;` }CEO% SCREEN OPENINGS 3' FROM EDGE PAN & INS. PANEL ST V LOADS ALUM A BASED T (MIN.) i11QQ E T❑ BOLT I ` '. IMPORTANCE FACTOR = 0,77 PRIMARY W C❑NNECTI '-> `''r s ± ``''.T : R ❑THER POSITIVE 1. ALL RIMAR MEMBERS ILL BE lf.. ./ . S P�(':• 5 ❑ FINISH'' GRADE ,...$�.. FASTENERS. 2. ANCHORS SHALL BE PLACED CzC� M."t{ s.TkAN 3" �,*&i'' - E OF 'CONCRETE SLAB OR FOOTINGS, E ALL CONC. .FASTENERS`MUS,0.1 :,;fEb. A.':#�}IN. [r`+F'%{)IT❑ S❑LID CONC. REGARDLESS OF e LENGTHS SPECIFIED' I1}i;A%DjiS'; 8; 4' CONC. SLAB 3. FASTENERS .FOR` ALUM, : s5'- SHAL rF 3>:(D ::i]N CENTER W/ 6X6 - 10/10 W.W.M. 4. FASTENERS SHALL HAVE;;;#'z !2' htt+iF<, 1 A;...�,StIR-.,BE PROVIDED W/ 1/2 INCH DIA. WASHERS W/ 8'XS' FTG. W/ i-#5 MIN. {?:: :t 5. CONTRACTOR IS -ARESP❑ICI` `+l'3[] INSULA . . MEMBERS FROM DISSIMILAR METALS FTG, & SLAB DETAIL - TO PREVENT` EtTR❑LYuT."2?.:%;lit `T 6. ALUM. IN''`1/ C <%''f 'r'+t +� BE PROTECTED W/ HEAVY BOOTED BITUMINOUS NOTE, FIBERMESH MAY BE USED IN LIEU OF 6X6 - 10/10 W.W.M. ❑t4>"E]f : f t ;« f1 PAINT OR �1Fi?F E7 Md 4fiA; �"'AN'! ACQUER OR THE WOOD SHALL BE PAINTED W/ TWO COATS ❑F-ALIiT���; :RAINT' iTiil>tHt ''JOINTS SEALED W/ A GOOD QUALITY CAULKING. FOR 6i30bMNS 5' DEEP OR GREATER INSTALL COL. 2'X3'X3' LONG X 1/8' 7. ALL ,AOARS TO 1#�;:,;,S� i* QSING AND LATCHING, W/5 FT. HIGH DOOR HANDLES WHERE POOL OR ADDITIONAL 2'X2'X2 Xl/e ANGLE EA. ANGLE EA. SIDE OF SPA 202 DOOR JAMB PLACEMENT IS OPTIONAL ALL OTHER COLUMNS 2' 2' I SFf tis<tc�ap. r iiF;t`rinit':a: OF INSIDE OF COL. W/ (3)- #12 X 1 LG COL. W/ (6)- #12 X 1' n,.r r`<-"zl;%'`%'.'•.;;., S.M.S. TO COL. & (1)- 1/4' X 2 1/2' LG..TAPCON LG. S.M.S. TO COL. & TTO . NC. 12 EA, CLIP 3 C2)- /8' X 2 1/2' LG 8.O O 'S' F#12 X 1' LG. S.M.S. TO COL. (TYP) TAPCON TO CONC. THIS 2 EACH CLIP. %'$ f x2" COL. (2)- 3/8' X 2 1/2' LG. TAPCON w f ?' TO CONC (TYP.) 4 PER COL.. AND O O O O io '% ' ' 1/ 4' TAPCON 2 18' ina 1X3 O.C. ELSEWHERE ZFoam FTG. 3' FROM EDGE 32' MIN ? •'' F2' - BETWEEN ��M2��` DELETE 1X3 FOR MI FASTENE MIN. OPEN PORT (TYP.) FRONT ELEVATION COLUMN ANCH❑RING DETAIL N❑TEI ANGLES ARE NOT REQ'D. FOR 202 DOOR JAMB COLUMNS. 3/8' DIA. BOLTS MAY BE 'ASHLEY QUICKSET', aka TAPCON ANCHORS. GENERAL DETAIL SHEET: PER FIE,C, 2004 EDITION W/ 2007 AMENDMENTS, EXP. tiN SITE -SPECIFIC PLAN SUPERCEDES ANY REQ.'S SHOWN ON UCTURAL GABLY. MEMBERS STRIP F❑❑TING SCHEDULE i TO' k#.CY W/ LOCAL BUILDING CODES, ANGS,CdLUMNS. ...................... x-AL. 6063-T6 � REWUNS.....:............................AL. 6063-T6 ............... ............................ WAL. 6061-T6 FPS RIVETS,,•_WASHERS ...,.,AL. 2024-T4 =NERS T❑' BE ALUM., N❑N-I4AGNETIC STEEL,yOR CADMIUM PLATED STEEL IKUNLESS`OTHERWISE NOTED MIN. FOOTING SIZES SHOWN APPLY TO NEW FOOTING'S U R E a B,Oo ONLY. FOR EXIST. SEE SITE SPECIFIC L E G A C CARRY BEAM SCHEDULE (FOR S❑LID ALUMINUM ROOFS) TABLE GIVES MAX. BEAM SPAN FOR GIVEN BEAM LOAD FI BEAM LOADS FOR ALUMINUM ROOFS n = L/120 EXPOSURE B oI- (10 PSF LIVE LOAD) JLL) P BEAM TYPE 4 5 6 8 9 1 0 12 14 16 18 20 ` .-3X3--.. 8.2 7.6 7.2 6.8 1 6.4 6.0 5.7 1 5.2 4.8 4.5 1 4.2 4.0 4LB 8.9 8.0 7.3 6.7 6.3 5.9 s.6 5.1 4.8 4.4 4.2 4.0 2X4 10.3 9.6 9.0 8.4 7.8 7.4 7.0 6.4 5.9 5:5 5.2 4.9 2X5 12.4 11.5 10.7 9.9 9.3 8.7 8.3 7.6 7.0 6.5 6 .2 5.8 SLB 1 0.5 9.4 8.6 7 .9 7 4 6.0 5.6 52 4. 9 4.7 6LB 1 1.2 1 0.0 9.1 8 .4 7. 9 7.4 7.0 6.4 5.9 5.6 5.2 5' 7LB 12.2 10.9 10,0 9.2 8.6 8.1 7.7 7.0 6.5 6.1 5.7 5.4 8LB 18.0 16.1 14.7 13.6 12.7 12.0 IL4 10.4 9.6 9.0 8.5 6.0 9LB 18.5 16.6 15.1 14.0 13.1 12.3 11.7 10.7 9.9 9.2 8.7 8.3 IOLB 1 26.1 1 23.41 21.4 19.8 18.5 17.5 16.6 15.1 1 14.0 13.1 12.3 11.7 STRUCTURE F❑❑TING (MIN.) REBAR WIDTH X DEPTH SCREEN ROOF 12' X 10' 1-#5 W/ UP TO 7LB BEAM SCREEN ROOF W/ 8LB 12, X 12, 1-#5 SCREEN ROOF W/ 9LB 12' X 16' 2-#5 ' SCREEN ROOF W/ IOLB 12' X 16' 2-#5 ALL S❑LID ALUMINUM 12, X 12, 2-#5 ROOFS COLUMN SCHEDULE (FOR S❑LID ALUMINUM ROOFS WITH SCREEN WALLS) TABLE GIVES MAX. COLUMN HEIGHT FOR GIVEN SPACING ,�z WIND LOAD = 30 PSF ROOF, 21 PSF WALL EXPOSURE B �a COL. TYPE 4'-0' 4'-6' 5'-0' 5'-6' W-0' W-6' 7'-0' 7'-6' 8'-0' 4LB 95 8.8 8.3 7.8 7.4 7.0 6.7 6.3 6.0 5LB 11.9 11.1 10.4 9.8 9.3 8.8 8.4 8.0 7.7 6LB 13.6 12.7 11.9 11.2 10.6 10.1 9.6 - 9.2 8.8 7LB 15.3 L4.3 13.4 12.6 12.0 11.4 10.9 10.4 9.9 SLB 21.7 20.4 19.3 18.4 17.5 16.8 16.1 15.5 14.9 9LB 23.6 22.2 21.0 19,9 19.0 18,1 17.4 16.7 16.1 9LBH 26.3 24.8 23.5 22.4 21.4 20.5 19.7 19.0 18.4 IOLB 3 0.9 29.1 27.6 26.3 25 .2 24,2 23.3 22.4 21.7 ❑PEN 2X4 OPEN 2X5 "SEF,ATTACHED SCHEDULE FOR ALLOWABLE HEIGHTS. 00- x ww x J O U � 1 J DATE, 02/05/08 SCALE, • N.T.S. SHEET, C C.T. TARNOWSKI, P.E. IRAL ENGINEER - FA. UC. 0050662 w N )w x a ¢oaJ U E t wL x w x a U rl cuw C7 1 v w m CUI�O ffiAgfs z M ^ O` V) I. --I CC" o , �t z ~o Q C,a �ON v 0-