Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTED PAPERS
DATE: FEE-L...�. HE St. Lucie County Building & Zoning Department 2300 Virginia Avenue SCA���® Fort Pierce,. FL 34982 772-462-1553 �� Lucie APPLICATION FOR STORM SHUTTER PERMIT county SEE REVERSE SIDE FOR INSTRUCTIONS 1. LOCATION/SITE ADDRESS: cX6O I M W 20-qP'I �:jz- -tJ C'T 2. PARCEL ID NUMBER: 4 _ (66S— DO3p-- ow"—) t -m ict d SECT TWP RNG MAP ZNG LU INIT 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY: t��czcz c� cJ E S�u`s'Cec1-s to (AedUC2��(�cv S 4. TYPE OF STRUCTURE: SFR OTHER 5. OWNERS INFORMATION 6. CONTRACTORS INFORMATION Name: AStt'(.m v 2-Z ` FL REG/CERT #: ��_ Q KD 0 `- ) Address: "Opt MW R04k swj G't COUNTY CERT#: City: ����� State: Business Name: Phone: ��� 343 O3G3 Zip:ShJ'sTZ- Type of Surface attachment: Wood Frame Concrete Masonry Other Product Type Minimum Design Pressure Product Compliance Report # Method of Attachment As per 1707.4.4.1 FBC 120 mph 130 mph 140 mph 140 Exp. C SBCCI Dade Other Anchor Type Anchor Spacing Impact Glazing Removable Panels F 3 -R Accordion k SYS N Roll U Colonials Other ALL YKUIJUCT, MALL BE LABLEll SJ3UU1 UK I)ADE COUNTY FOR DETERMINING IMPACT RESISTANCE FROM WIND BORNE DEBRIS. **SEE FINAL INSPECTION PROCEDURE FOR EXISTING RESIDENTIAL STRUCTURES ON BACK. 7. VALUE OF CONSTRUCTION: $ 5 DD. 11 OWNER'S AFFIDAVIT: I certify that all of the information contained in compliance with all applicable laws regulating PRINT QUALIFIERS/OWNERS NAME STATE OF FLORIDA, COUNTY OF �&T ACKNOWLEDGED BEFORE ME THIS S_DAY OF �V ` WHO HAS PRODUCED all work will be done in SIGNATURE OF WHO IS PERSONALLY KNOWN TO ME, OR AS IDENTIFICATION. TYPE OR PRINT NAME OF NOTARY *NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FIREM WITH YOUR LENDE R AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. 11 ublic State of Florida Stinemission DD79358806/01/201r 1 ` ' INSTRUCTIONS Please complete all information in the spaces provided. All information must be Printed (use black or blue ink'onlv) or Tvved. This application for Shutters to be used for only those activities that is not otherwise included under a primary building permit. This application for Permit may not be used for any activity that includes any type or kind of structural alteration. Building activities involving structural alteration, in addition to the installation of Shutters, must be permitted through the regular building permit review process. The information to be provided with this application includes: 1. LOCATION/SITE ADDRESS: .............................................. Indicate the street address, or general location, of the property on which the building activity is taking place. 2. PARCEL ID NUMBER: ........................................................ Indicate the Property Tax Identification Number for the property on which the building activity is taking place. 3. DESCRIPTION OF PROJECT OR WORK ACTIVITY........ Briefly describe the building activity under permit application. 4. OWNERS INFORMATION: ................................................. Indicate the name and address of the owner of the property on which the product is to be installed. 5. CONTRACTORS INFORMATION: ................................... 6. VALUE OF CONSTRUCTION: ......................................... Indicate the State of Florida (if applicable) and St. Lucie County contractor's registration numbers, and the name of the business doing the work. Indicate the total value of the work to take place. Total cost of construction includes all material and labor costs associated with the building/construction activity. The value of construction is used to determine the amount of permitting fees to be assessed. St. Lucie County reserves the right to question and/or modify the indicated value of construction if it is demonstrated that the submitted figures are not consistent with similar types of construction. All applications for the installation of Shutters are to be submitted to the St. Lucie County Building and Zoning Department, St. Lucie County Administration Building, 2300 Virginia Avenue, Fort Pierce, FL 34982. All applications for Permits must be complete and filed with the Department no later 4:30 P.M. each business day. No applications will be accepted for processing after 4:30 P.M. For assistance in completing this application, please contact the St. Lucie County Building and Zoning Department, at (772) 462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday. Following the issuance of this Shutter Permit, the scheduling of all required inspections may be made by calling (772) 462-1261. INSPECTIONS ** EXISTING RESIDENCES: All shutters must be installed and in place at the time of the final inspection, except for Egress Windows and Doors where one panel must be installed and the remainder must be by the opening for the inspector to verify remaining panels. ** NEW HOMES: All shutter panels must be installed at time of final inspection or inspection will fail and C.O. will not be issued. SLCCDV FORM NO: 006-05 Contact Information AlUMINUA! &SRUlTER CORP. Date: 10/5/2004 Name: MR. & MRS. GEORGE & CYNTHIA BALDUZZI Associate: GEORGE YUSCAVAGE Taken By GEORGE YUSCAVAGE Job Address: 2001 ROYAL FERN COURT City, ST Zip: PALM CITY, FL 34990 Subdivision: HARBOUR RIDGE Heard How: Referral Referred By: Phone Vs (772) 343-0393 Bill To: 2001 ROYAL FERN COURT City, ST Zip: PALM CITY, FL 34990 Job Site Directions Inquiries Date I LeadType'interested In 10/5/04 ISales I Lead Status: Bid C SP AC, Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 hftp://stiucieco.gov/ce Date: 11 July 2008 Job Address: 2001 ROYAL FERN CT Received By: humphreya Paid With: MC Paid By: DENNIS B STINE Building Receipt Receipt M 0000064202 'ermit Number: SLC- 0807-0222 Amount: $82.40 �redit Card Number: XXXXXXXXXXXX3232 Check Number: Sign: i 3001 S.E. Gran Park Way, Stuart, Florida 34997 (772) 287.6476 • (800) 244.4143 ° FAX (772) 287.9740 E-Mail: sales@gulfshutters.com www.gulfshuffers.com License #CRC058017 ORDER FORM Name 7"t �`s%�, .� �r Date 0 Address _ °�' r ��� a_(a Subdivision City ,G°°- State - Zip'' l Phone (Home) 3 W5 — -5 � (Work) Approximate Installation ~)PG # TYPE I OPENING WIDTH I OPENING HEIGHT I TRACK COLOR COLOR PANEUSLAT I GAUGE I STACK R/L I LOCK I/O REMOVABLE TRACKS BUILD OUT MOTOR/ CRANK STORM BARS C�/ ` ' , 5-3 f !3777 ?Z I6 ` Q za APPLICATION I FLOOR Electric: Buyer agrees that any necessary electrical connections will he made at the closest souce of power. Any changes or variations will be an additional charge. DO NOT SIGN THIS CONTRACT UNTIL YOU HAVE READ ALL CONDITIONS OF THIS AGREEMENT Interest - Buyer agrees to a 1'/2 % per month interest charge on any unpaid balances. Costs of Collection - Buyer agrees to be responsible for seller's allorney's fees (both trial and appeal) and all other costs of collec ' n in the event fullT5E%;T_QAte ined herein is not made within 10 days of the completion of the work outlined herein. Acceptance of Proposal - The above prices, specifications and conditi s are satisfactory pted. You are auth rued clothe work as specified. Cancel] '6n Fie 20% of contr�Ft. Pa entwill be made as outlined -above. Signature Salesperson _� �%�t°�- Date 4� (� Gulfstre rfiAluminum nd Shutter Corp. ' Page % of / Key Storm Panels - SP Accordions - AC Bahamas - BA Colonial - CO Rollups - RU Lexan - LX Garage Brace - GB Application Key Wood - W Block - B Stucco Over - SO DEPOSIT 50% 3 00 BALANCE ON��_ COMPLETION It is understood that there are no verbal agreements and all items discussed are covered by this written contract. This is a proposal until signed by an officer of the corporation at which time it becomes an executed contract. Acceptance by owner must be within 30 days of proposal date. Buyer may cancel this contract within 3 working days after signing. No changes in measurements will be allowed except at prices mutually agreed upon, at the time these changes are made. Any physical orverbal changes aftersigning must be approved in writing by both parties. All agreements are contingent upon strikes, lockouts, accidents, acts of God, weather, fire, carrier delays, delay or failure to receive raw material deliveries, or by other causes, whether of like or different nature beyond our control. Owner to carry fire, tornado and other necessary insurance. Our workers are fully covered by Workmen's Compensation Insurance. All material is property of Gulfstream until final payment and can be removed if not paid. .YEAR GUARANTEE vwvA vlulI rU1K VVUY, JIUU111 r1U11UU'34yy/ (772) 287��72) 28977244 40 - 4143 FAX A[UNINuMR sHunER CORP. E-mail: Jobrien@guifshutters.com www.gulfshutters.com Do It ®race. Do It Right Lic. #MC00231, SL 1211, PB# U-17051 & CRC58017 Since 1979 LAYOUT SHEET Storm Panels - SP Accordions - AC Bahamas - BA Colonial - CO Key Page of.. Rollups - RU Lexan - LX Garage Brace - GB AW r ..a • ., ' . ,.. • ,n... ,. r... r . ........ :............ . . . sara •, .{/" ,., . �• ,., .•...• �• . .... • n , r �p .............. ..... .... :.::.::.:.:.: :... .:. , ........... :.:.... ..... ...,:.::...: :.... .; ... ;..;.............; ......::':":�' ..: .......................... :.:.. ..;.;.:.: . :... :: ° :::::: , c 16 'F" t7 wlJ o,� —. ...... A, ,' :: Special Instructions, -14 e/, i z-, / 5, / y ;,-- Kl pcorvy I�L+CZ�G'Yt-% Signature Date Salesperson� .� rl �"l .1. -a BCIS Home Log In I Hot.Topics ! Submit Surcharge ' Stats & FactsI Publications I' FBC Staff BCIS SiteMapL ��"� '-Product.Approval USER: Public User Product_Approval_Menu > Product or_Appllcation,_Search > Application List > Application Detail FL # FL389-RI Application Type Revision Code Version 2004 Application Status Approved Comments Archived t— Product Manufacturer American Shutter Systems Association, Inc. Address/Phone/Email 4268 Westroads Drive West Palm Beach, FL 33407 (561) 841-5480 bfeeley@easternmetal.com Authorized Signature Bill Feeley bfeeley@easternmetal.com Technical Representative Address/Phone/Email �u i U � �-�rg� • ; 4;�i � :fig • ! . - . - Category Shutters Subcategory Accords n Compliance Method Evaluation Report from a Florida Registered Architec Licensed Florida Professional Engineer ig-1 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name Walter A.. Tillit,.Jr. P.E. who developed the Evaluation Report Florida License, PE=44167 p:llwww.floridabuilding.orglprlpr app dtl.aspx?param=wGEVXQwtDgvYYHH2vJvx53MwsXdCOtO... 3/17/2006 Quality Assurance Entity Validated By Certificate of Independence National Accreditation and Management Institute John Henry Kampmann Jr. Referenced Standard and Year (of Standard) Standard ASTM E-1886 Year ASTM E-1996 . 2002 2002 Equivalence of Product Standards Certified By Sections from the Code 1609.1.4 1609.1.4 Product Approval Method Method 1 Option D Date Submitted 8/5/2005 Date Validated 9/23/2005 Date Pending FBC Approval 9/29/2005 Date Approved 10/11/2005 Summary of Products FL # Model, Number or Name Description 389.1 Bertha HV Accordion Shutter (Non-HVHZ)- Drwg #05-196 Extruded aluminum interlocking blades i Limits of Use by tracks (top and bottom) for storm pr Approved for use in HVHZ: Installation Installation Instructions pproved for use outside HVHZ: Verified Impact Resistant: Evaluation.Verified Reports Design Pressure: +/- - PTID_389 R1_T ND CERT INDEPEENCE 0715 01 Other: This product shall not be installed within High Velocity Hurricane Zone as defined on pdf PTID 389_R1 _T_Drawing No.05-196i"p� section 1620.2 of the Florida BuildingCode. . 389 R1 T PROD EVALUATION. R 05-0 5-0715 01 pdf Back Next DCA Administration Department of Community Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 www.floridabuilding.Org/pr/pr_app dtl.aspx?param=wGEVXQwtDgVYYHH2vJvx53MwsXdCoto... 3/17/2006 1. BERTHA H.V. ACCORDION SHUTTER SYSTEM SHOWN ON THIS PRODUCT EVALUATION DOCUMENT . LDI I IqS BEEN VERIFIED FOR COMPLIANCE IN ACCORDANCE WITH THE 2004 EDITION OF THE FLORIDA .6E UILDICODE. THIS ACCORDION SHUTTER SYSTEM SHALL NOT BE INSTALLED AT HIGH VELOCITY HURRICANE ZONES. DESIGN WIND LOADS SHALL BE DETERMINED AS PER SECTION 1609 OF DIRECTIONALITY IINDSPEED S REQUIRED ED IN ACCORDANCE HEJURISDICTION ICWRH WHERE �SH9UUTTER WILL BE INSTALLED, THE ABOVE MENTIONED CODE FOR A THAT ANCHORS LOADS THIS WINDDLO DA gTESTED. ST D' WERE NOT OVERSTRESSED , A 337, INCREASE ' IN �D FOR A STANDARD, IN ORDER TO VERIFY BERTHA H.V. ACCORDION SHUTTER SYSTEM'S ADEQUACY FOR WINO AND IMPACT LOAD HAS BEEN �4I USED IN THEIR ANALYSIS, VERIFIED IN ACCORDANCE WITH SECTION 1609,1.4 OF THE ABOVE MENTIONED CODE AS PER qTL REPORTS #0214,01-03 AND #0715.01-03 AS PER TAS-201,iTFS-202 AND TgS_203 PROTOCOLS AND AND E-1996 STANDARDS. gSTM E—tees 2. BERTHA H.V. ACCORDION PINS (HV SCREWS), USED AT BLADES KNUCKLE AND FOR DIRECT MOUNT. CONNECTION TO TRACKS SHALL BE >� 14X2.75 AND SCREWS WITH 135C COATING YIELD STRENGTH AND 180 ksi TENSILE STREGHT. PINS SHALL BE COATED WITH BERTHA 14X1.75 RESPECTIVELY, REGHT. MINIMUM SERIES STAINLESS HV RI C N SH SHUTTER COATING SYSTEM AS MANUFACTURED BY APPROVED COATING APPLICATORS, REGISTERED STEEL AMERICAN SHUTTER SYSTEMS ASSOCIATION, PINS MUST BEAR THE HV MARKING AP THEIR HEAD 3• ALL ALUMINUM EXTRUSIONS SHALL R ALUMINUM AR 6063—T6 ALLOY AND FY 25,0 ksi MINIMUM (UNLESS OTHERWISE NOTED). TEMPER, WITH 4. ALL SCREWS TO BE STAINLESS STEEL 304 OR 316 AISI SERIES OR STEEL AS PER DIN 50018 WITH 50 ksi YIELD STRENGTH AND 90 ksi TENSILE STRENGTH, CORROSION RESISTANT COATED CARBON 5, BOLTS TO BE ALUMINUM ASSOCIATION 2024—T4 ALLOY AND AISI 304 SERIES STAINLESS STEEL WITH 35 ksi MINIMUM YIELD STRENGTASTM A-307 GALVANIZED STEEL, OR G. SEE SHEETS 10, 11 AND 12 FOR ANCHORS SPECIFICATIONS. 7. THIS BERTHA H.V. ACCORDION SHUTTER SYSTEM IS PATENT PENDING• APPROVAL. ARE COVERED, IN WHOLE OR IN PARi BY U.S. COMPONENTS OF THIS PATENT ISSUED TO EASTERN METAL SUPPLY, INC. 8. IT SHAL BE THE RESPONSIBILITY OF THEE C�ON� i��a�E HE SOUNDNESS (IF THE CONS 00� AER COMPONENT EDGES WHICH REMAIN, CONTINUOUS CONTACT STRUCTURE THRU FASTENING IN g• �+CH UNIT MUST BEAR A PERMANENT LABEL N A VISIBLE PLACE W TENANT OR HOME OWNER THAT THE H.V. LOCKd DURING PERIODS OF HURRICANE WARNING. FOR EGRESS CO DR10N5, WARNING NOTE INSTRUCTING THE W OR ALTERNATE LOCK MUST BE PROPERLY LOCKED MUST REMAIN IN THE LOCK), AN INSIDE ALTERNATE LOCK AN INSIDE HV LOCK WQ (WHERE KEY i0. SHUTTER'S MANUFACTURER LABELS 0R EGRESS H.V. LOCK SHALL BE USED. ONE LABEL SHALL BE PLACED FOR EVERY OPENING. LA13ELACED NSHALL BREAD VASE OLLOWSTION, AMERICAN SHUTTER SYSTEMS ASSOCIATION WEST PALM REACH FL INC. FLORIDA STATEWIDE PRODUCT APPROVED. 11. BERTHA H.V. ACCORDION iN THIS.DRAWING PLUS ASHUTTER SYSTEM'S INSTALLATION SHALL COMPLY WITH SPECS INDICATED IS APPLIED IED T0. AN BUILDING AND ZONING REGULATIONS PROVIDED BY THE JURISDICTION WHERE PERMIT 12. (a) THIS P.E.D. PREPARED BY THIS ENGINEER IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT; i.e. WHERE THE SITE CONDITIONS DEVIATE FROM THE P,E.D. (6) CONTRACTOR TO BE RESPONSIBLE FOR THE SELECTION,PURCHASE E SAFETY OF THIS PRODUCT, ED ON THIS PED., PROVIDED HE/S E .DOES NOT DETAILED ON THIS DOCUMENT. CONSTRUCTION:SAFETY AT SI AND INSTALLATION INCLUDING LIFE TE FROM HE HE (c) THIS P.E.D. 'WILL BE CONSIDERED INVALID IF ALTERED BY ANYTMEANSNT�CiOR S�RESPONS BILITY CONDITIONS (d) SITE SPECIFIC PROJECT WILL BECOME THE ENGINEES SHALL BE PREPARED BY A FLORIDA REGISTERED ENGINEER OR AR PROPER USE OF THE PCHITECT WHICH R OF RECORD (E.O.R.) FOR THE PROJECT AND WHO WIL BE RESPONSIBLE FOR THE ,E,O. ENGINEER OF RECORD, ACTING AS A DELEGATED ENGINEER TO THE P.E.D. SHALL SUBMIT TO THIS LATTER THE SITE SPECIFIC DRAWINGS FOR REVIEW. RECORD THAT PREPARED IT. (e) THIS P,E.D. SHALL BEAR THE DATE AND ORIGINAL SEAL ENGINEER AND SIGNATURE OF THE PROFESSIONAL ENGINEER OF -- IL E C O JUIL:.2 g '2 Y.:, . TILUi TESTING ec ' . " ;ass x.v. aTE ENGINEERING COMPANY Faa a (Oj09)e71015]i 3I80 ��mall: q.,,.p!,��i'i�a+° ':' ICBM"," F73ab'c�' `• P.E. SEAL/SIGP}ATURE/DATE xltacaOoxLeom NALTER ti �LLIT J. P. E. ""A -441 fi7 F,B,C-Mon high V,I,Clty NuTricane Zone ® 2003 EASTERN METAL SUPPLY, INC. A■S,S BERTHA HV TM American 5huttarAn ACCOrL�10 Systems n Shutter Systen Ae�cclaticnl Inc. N. x OEswpTIC 4268 WeStroOdS 1 OLTE Drive M aa- , Dawn • JAS. West Palm Beach, FL 33407 2 "I'" DATE: 7/1�/0 DRAWING No 05-196 4.371' 857' -:,-.n- NMI COVERXVER-'� 5--v Ug' PATENTY# 5458i79 3 (ryp. 4 9 8 Hy A2a-A0Aejm_WU VARIES 2' 1.91a* D' UN& 060, o. 670 •68G, 3.5 0- --------- ..... . .. 3 1- ea.72* THLaLimcs. 93' 7 1- VV--a aT E km & 19(-SE&-WTi-N—G) ryp 125' TYP- O Ev.:, - .. =,...,T. @X—E=E-A-E= (q) UYALL� 07(r- 072 B .11 7.092 o. -- Ggaggmfflw1 t 0.062" 0.062. 2. 2' 0-052' 23- 0.052- 2- 4' .052- 2° .062- 11LUT TESTING & EN.1-E=.. COMPANY 53 • Le • P.E. SW' . Talff Jr.Ip. E. "IUDA Lk- f 44 67 AmSm&A Am@rlcQn Shutter Syntgm". Association. jr, 42,�a westroads Drive West F alm Beach, FL33407 F.B.C.Mon "I'll "Ill.111,111,111,11,'ll""I'll",�'ll""I'll""I'll",ll,"'I =,High Velocity Hurricane Zan 2003 EASTERN METAL SUPPLY, IHC. BERTHA HVIV, Accordion Shutter Sv, m DRAWING Na 05-196 VARIES, 12" MIN. 1/4' h20 s,s. OR ]/1"v-16 1 130" ACETAL O 7HU SCREWS. 31/2• WHEEL #3 NYLON #1 LONG 3/8- ASSEMBLY AT WASHER RECESSED AT EVERY NYLON BUSHING. o OTHER c m * KNUCKLE 14x2 3/4' H.V.ch I 1/+.,A ACCORDION PIN�I I j RO� U .3 5.0 I ¢z x #8 HEAD Y2 SHORTTE (SEE•NOSHET ) RECESSED B.CEANYLONf I ( naN 83IH.V.�CR $ T -ZOS.S. L92 BUSHING. n ACCORDION CCRO PIN W/s HERO 11 1I lT -E40 h� ' 4•-20 I s // HV I I 4� • 0 83 NYLON ssYs. TNRFAOEp CASE t 4'-00 ACCORDION I BLADE Hy , u-j I f-� 1 ; (2 TTp.) Hauswc kT++7060. D¢ CAST i I_- I—� HAT WASHER n c m anlcm PNIIIEO HausNa w,V.¢L PIN ACCORDION n H 0 'n WED PAQNm PIN U.315 0 ® "n o Res 7wR 0.188.0 AISI •9 5' 0.870•x3/16'- - - Iwca. 302 SERIES s.SS. THICK NYLON RIVETSI' WHEEL �8' p BRA45 C1LN0ER nAISI 302—}47I5'0 RLYs (awaue a uss uHaER SERIES s.s. y4$-0 I ' a PLAIEp •. (CHROME PLATED)WHEEL I I .HLQCK%= rRl ac 'u'' :1=n,.� I CARRIAGE " ( ` j SHORT �1 LONG _ II I RECESSE, I ( ECESSED YS' (SEE NOTES ON SHEET 4 HV HV D I O E NYLON BUSHING PINYLON . ACCORDION PIN BUSHING ACCORDION ( I I I � I 50. O.o I I B E �I • I 'I I I _ PLAsnc HEAD- NOLDED To SCREW CI .LONG RECESSED Ln f —O ' BLADE 1 R NYLON BUSHING. c'•1^L .350' AFTER RIVETING 01 LOG I I . 9�ORn RIVETING(1`-- - PICAL•" SHUTTER ASS .� • I NYLON BUSHING ! 1 A 114 e n olvw . t,. . THUt:9Sr•pE�;rLZ�J SCALE: 3/B' = 1 00.324' A142 3/4' H.V. ® ALTER j pGK (T0 HV a- •048 ACCORDION PIN $'+.a 3/+' H.V. TYP.W/ #8 HEAD ACCORDION PIN (SEE' NOTES ON SHEEP 4 0 1 i W/ 8B HEAD 1 �. *:SERIES O444 ALUMINUM (2024-T3 ALLOY) 8� I LARGE FLANGE THIN SHEET NUTSERT. I III J PART Y 0820, AS MANUFACTURED BY AVDEL CHERRY UMRN, PARSIPPENT, : =7LVNEELRI'An ( ' NEW JERSEY 07054 OR EQUAL. -�CAR9SE T;tlli J. • "`�'-`�----..�•N:rs. ASSEMBLY-•eVnrlr N.T.S � F.B.C.(Non High Velocity Hurricane Zone) 02003 EASTERN METAL SUPp Y, L INC. IL C G INC. �■�■ BERTHA HVTM �# TILLIT TESTING ac ENGINEERING COMPANY �.�■ Accordion Shutter S = Amerla6n' S ,,a� eese N.R. le1h, sr, s1.. wq 1'wce+q cnn hUtter $Yltem! System k y'•y'• . L Phone : (30S)971-1570 . �' FUMWA 10111 Ass9clation EY' H OEscRIPNON _ Fay : (]a5)871-1571 1 111C. OALTE Orevn JAs. ".. n �. a-mm1: Ultecovvdevm 4268 Westr0ods Drive 1 °p61dj VU- DATE: 7J73/05 xv�3� Ee-ooaeTla West Palm Beach, FL 33407 P. SEAL%�1 RE/DATE WaLA RILR J. P. 6 E. a DRAWING No FLORIDAORIUc. � 44f /7 05-196 *NOTES ON I OCKING RODS U 1 1 0C D A ATE LOC 1• EdA ION. W LONDIi10N�i1 ONE HV LOCK ©SHALL BE USED FOR ANY SPAN AND INSTALLATIONS AT ANY ELEVATION. HV LOCK ® MAY BE USED AS AN INSIDE OR OUTSIDE LOCK, ATTACHED TO Q OR ® CENTERMATES WA2) 1/4"0-20 x 1/2" LONG FLAT HEAD S.S. M.S. LOCATION OF Lncw cu", SHUTTER ELEVATION. _ 2.an HV LOCKS MAY BE USED AS AN INSIDE OR OUTSIDE LOCK. CONNECTION. OF LOCKS TO CENTERMATES OR IL10N f1>><1: IF 1E1IRED, FOR BETTER PERFORMANCE OR FOR SECURITY PURPOSES, UP TO TWO SHALL BE AS INDICATED ON NOTE (1) ABOVE. LOCATION OF LOCKS SHALL BE AS INDICATED ON TYPICAL SHUTTER ELEVATION, O 3• flPIlQlyeL CON—`I110N Jf7, LOCKING RODS CARE NOT REQUIRED AT HURRICANE POSITION, BUT MAY BE USED IF DECIDED TO ENHANCE SHUTTER PERFORMANCE. LOCKING RODS UU OR AN ALTERNATIVE DEVICE MAY ALSO BE USED AT STACKING POSITION (NON HURRICANE POSITION). 4• EAMLLAAIQ.. CONp�g� ONE HV LOCK ® SHALL BE USED AT CORNER CENTERMATES FOR ANY SPAN AND ICORNER NSTALLA710N5 AT ANY ELEVATION, HV LOCK ® SHALL BE USED AS AN OUTSIDE OR INSIDT HEAD s sE LOCK, ATTACHEI TO BOTTOM SHAD BE T USED. LOCATION OF LOCK25HALLGBE AS NDCATED M-TYPICAL SHUTTER R ELEVATION. SHUTTER SPAN SHALL BE DETERMINED AS PER SCHEDULES SHOWN ONION SHEET 9. LOCKING RODS Q AT TOP MAXIMUM 8. ALTERNATE LOCK 1 MAY BE S'M IN LIEU OF HV LOCK FOR ANY SPAN AND INSTALLATIONS AT ANY 1/4%ELEVATION. ATERN TE LOCK W7 MAY BE USED AS AN INSIDE OR OUTSIDE LOCK. INSTALLATIONS CHMENT F ALUM RNN T4As SHOWNMONCALTERNATE SECTO 0 OR TION NENTERMATES 12, SHEET HALL BE MADE W/ 1/4"0-2px3/4" -@D. 0.I&N - 'IJeR9'ROcAO OHO OCR O iOeRO♦O c�T • " :! 1L Grr q®INe. • TILUT TESTING $ ENGINEERING COMPANY �'• - `,:_ .. ,.. : ,yam'ew x.x. aeu. . '•'I •.{• ;,,TI7{•,5�, s�. S te. Phvnc : (]OS)971 ,is]oWWxV1 W13015, FLORIDA ]]ILB 4—mae: .�� NIL ... a l.cam�5)E71-1S]I P.E. SEAL'�516NATURE/DATE WALTEREA. TILL[} ,1r. P, E. FLORIDA ue. p 441s7 M 'Am S n 3,A■ Amarlean Shutter Syst®ms Association, Inc. 4268 Westroods Drive West Palm Beach, FL 33407 O- ©.RO CROCRO- O — NLL3 OF CORNER CENTERNATE F.B.C.(Non High Velocity Hurricane © 200] EASTERN METAL SUPPLY, INC; BERTHA NV TM Accordion Shutter System [ OESORIPRON DATE erovnp$y.96U3Wry DRAWING Na 05-196 POU OR WAL POURED CONCRETE REQUIRED CONCRETE ANCHORS - (SEE SCHEDULE ON SHEET ICI) I". MIN. SEPARATON A EXISTING 1 GLASS-1 I1 ,'.� w�41.L MOUNTING INTA t`eTlrtiy UI'! LL :MOUNTING IN�T6i r `eTF IO NEIE ANCHORS SCHEDULE ON 10) '/4H,-EOzO/,4" S.S. NQE_FOR COMRINATON n� e MACHINE SCREWS USING 1/4"-20 NUTS ® 12' O.C. I- SEE SHEET O FOR TYPICAL SHUTTER 1• MIR, 2- MOUNTING SECTIONS CAN BE COMBNEASSEMBLY IN ANY WAY TO SUIT ANY INSTALLATON. EO p Q 0 E + E• G. - EDGE DISTMNCE (SEE NOTES k SCHEOU LE ON SHEET 11) 1 ii t' 11 1 MIN. SEPARATION w LAS EXISTING 1 TO GS GLASS I 1 lyALl MOUNTING I 'STA I eTl EXISTING I MIN. SEt 0 OR POURED CONCRETE --� ' ICpNCRE1E ANCHORS` TRUSS HEAP MACH S.S. PHILLIPS SCREWS WALL REQUIRED LOCK SHEET 10)SEE OULE ON USING I/4'-20 NUTS 012. D.C. ® WAIL MOUNTING INSTA LATIO ' INSTALLATION DETAILS ",j : •f� F.B.C,(Non High Velocity Hurricane Zone) .ta © 2003 PASTERN METAL SUPPLY, INC. i L E-O Nc. s S+ A BERTHA HVTM :.� ■ ■ ' ■ Accordion Shutter System 71LLR TESTING ec ENGINEERING COMPANY Ahierlcan Shutter % 0'a N.Y. D8�• SC. 54, ]as. MRMU[' WRDENS. FLUFUDA 771, SyStOh19 PNane : (3Ds)9TI-'S�a . FR; ; Assocfafloh, Ihc. " DescwFn9x (�Ds)en-Isat DATE a .R "'"�'�iH✓ v = a-moil:tilt 0033"C"I'" 4268 Westroads ' m-aFa • +As. EA. "LLIiTI9 West Palm Beach, Drive YnFim DATE; 7/t3/05 P.E. SEAL/SIGNATURE/DATE W"L " A RLtlr 4 P. E . FL 33407 FLDRIDA Ua / 641fiT DRAWING NO 05-196 POURED CONCRETE ANCHORS CONCRETE REQUIRED (SEE SCHEDULE ON SHEET 11) ` EDGE I F 1 UGTP_EOR COMBINATION O�EaONS. E. s1AB a /� ASSEMBLY SHEET, 3 F APPUCAeI< 1 7• MIN. SEPARATIpN�rO OR TYPICAL SHUTTER EQI Q I TO GLASS i 2- MOUNTING SECRON5 CAN M ANY WAY TO SUIT AI COMBINED ANY INSTAl1ATI0N. (3 OR EXISTING - i E. D. a =EDGE 015rpNCE TINGI i i 11 I 1 1 I I (SEE NOTES & SCHEDULE ON SHEET 11) ASS— I 1 1 II � J I 1• I E 1 EQ 1 MIN. SEPARATION w i! / EDGE OF TO GLASS 1 // SLAB IF APPLICABLE POURED CONCRETE E. 0.* REQUIRED FLAT HEAD CONCRETE ANCHORS ® I I OUNTING INSTAL L ATIVN © (SEE SCHEDULE ON SHEET 11) �'K—py��rOUNTIN INS'rA L ATIn T ' EDGE OF - SLAB IF APPLICABLE POURED - CONCRETE REQUIRED Ew g SCREWS a 9' S.S. C, p°T HEAD TEFL i S.S. M.5. W/ NUT ® s• 4'91p T '#10.3/4' NIX WASHER HEAD I TEX SCREWS a 12' O,C. CONCRETE ANCHORS 1 (SEE SCHEDU LE ON SHEET 11) EDGE 0 i� —SLAB IF F I APPLICABLE 1 THIS INSTALLATION SMALL BE pp�---++--- REMO VABLE WHEN PERFORMED D� y FAI / ADJACENT TO AN OPABLE EXIT ENRiM1NCE i CONCRETE ANCHORS (SEE SCHEDULE ON SHEET 11) 7/�M EDGE OF BLAB IF APPLICABLE LI AJOR ��U— NLNSTA I ATIn11 CONCRETE RECL➢REED D E. O.f ® FLaOR MOUNTING INSTALLATION t - INSTALLATION DETAILS ��--; e l�,'s• F. C.(N.n High Velocity Hurricane Zane' �`,.(�ti• 'd; ©20D3 EASTERN METAL SUPPLY, INC. �._JILIEwS r4RRTHA HVIN TILUT TESTING k ENGINEERING COMPANY Am�rlcan $� It , Accordion Shutter S B355 Ns 35lh. SL s1. sw. NNDmA sv:DENs hUtter $yatoma ysten 71-13( 771 EB A1eoNation, Ina, EY' " DESCRIPTION PAunO : (J0.)H71—ISdO .Fax ; DATE '.•.: , .... r,. (3os)BT1—u31 1 Drvrn . J.As. moll: Nt.0671s eom 4Z66 Westroads Drive Z °" °1-°" T/1A/m DATE: "— wALTEBEw niR P. E. West Palm Beach, FL 33407 P.E. SEAT /$I .. j /DATE FLORIDA u�. i aa1e7 3 DRAWING No 05-196 oUT eo r4 I N EXISTING GLASS Ji * SEE NOTES IY ON LOCKING RODS Z. W LOCKS AND ALTERNATE LOCK @k ON'sNEET 4. B OR©OROOR . 0ORO,i10R J z•.z•.I/e•.G'-2 — —NG — — — — — — — — — xIsn GLASS ft SEE END WA rn�•�. T, DETAIL. (60fi3-TrALL01') ALUM. I AND W/(2) 1/a'1 TAPCON ANCHORS TO CONCRETE 3 1/4• 7/2• — — — .� —. — — — — — — — — -- — — — - — — — ON _ cry a H - i — — — (TOP/eO7TOu) t I (4)ptO.t/2• S.M.S. 70TUBE AT EACH ANGLEj110.3/4• S.U.S. ®,2• O.C. FULL 7• OPP CENTE�RMATES 6 1/2" — — — — — — — — — — — 7, LENGHT. ; w Loc W SYMMETRICALK CENTE�ES I N LOCK r' MIN. U * SToAI,ASSN U — - — -- A L OR O �M OR L - — - A S e L oRO STING GLASS 1' MIN. SEPARATIDN TO GLASS I L Liu I LJ- U SECTION 12 AT rnRru(: o nr.1T�..... __ Qua I tnMA rE 3 L)oROM SECTION OUT 12 W — — — — — — — — — _ - (—E -NG GLASS POURED CONCRLrE GR CIINCIE7E BLOCK WALL SYMM— E:FRiC C NTE MATES W LOCKI _ arrIGNA1 WO*. _ IN — — — — _ — B OR©OROOR — L J— _ — — — 1• REOUIREO — — (INTERIOR) OR O I oR MIN. To LASS K - — - — - U * I A ANCHORS 1p VARIES 16. O.C. W1* U* L ORO oUT ALTERNATE SECTIO r 1 SECTION 1 AT 6 '/2" MAX SLACK SLACK DETAIL (IF APPLICAIL "max F.B.C.(Mon High Velocity Hun,;Kj ane one ©2003 EASTERN METAL SUPPLY, INC. s-fr IL EC01mc. AmSmS,ABERTHA HV1v TILLIT TESTING & ENGINEERING COMPANY ■ Accordion Shutter Sy - fi,5,g American 5huftar Syatame o, N Ste1] •�. sL. sc.. ,Os, xRcwlA cAnuExs. MluaA „1ae AmOCICtIC t Phana ; (705)97t-157a .Fox ; (,a,]971-157I n■ InCi. GLscRIrnGN GAtE .''" a -man; unmooaa.mm 4268 Westroads Drive I J,AS. n °'0 w'61•/�./w DATE: 7/T3/o: J� -g r- WAL7MEZOUGG T 407 , P E.West Palm Beach, FL 332 P.E. SEAL%SIGNATURE/DATE FLaRIaA Ue. 1 44167 DRAWING No 05-196 POURED CONCRETE OR CONCRETE BLOCK WALL POURED CONCRETE REQUIRED OR CONCRETE / F BLOCK WALL REQUIRED / L EXISTING GLASS /"-E76511NG CLASS 2' MIN ' ED I" MIN. i i SEPARATION 1" MIN. TO GLASS 1/I6"x3' MAX, (6063-T6) S O GLASS ON S CONT. ALUM, CLOSER TO GLASS (LOCATE ID PLATE. (LOCATE AT EITHER EITH R SIDE OFO) SIDE OF N& 1 MIN 1/2" MIN. B10x1/2' S.M.S. I I. a 16' O.0 a 16" O.0 _ POURED CONCRETE OR CONCRETE A pru,oro CONCRCM BLOCK WALL REQUIRED OR CONCRETE f EXISTING GLASS BLOCK WALL REQUIREC - /- f 2` MIN.. EXISTING GLASS I' MIN, EP A�110�NTO --I I Giolo-looRe SEE DETAIL X FOR ^ SEE DETAIL) FOSIDE CONNECTIONSIDE CONNECTTO TRACKS TO TRACK //�P� OR®+OORO OR©OR®OR® ORV OR(E)OR(E) END CONNECTION DETen OR®+OORQ °R®; ORRp 1O E:ND CONNECTION pF A�� Q ND CONNECTION DETAIL' 3 POURED CONCRETE OR CONCRETE BLOCK WALL POURED CONCRETE OR REQUIRED zCONCRETE BLOCK WALL - REQUIRED EXISTING CLASS - GLASS EXISTING -� lC GLp 1' MIN. B10z1/2" S.M.S )) TOSEPGLASS / ® 12' ox SEPARATION T TO CUSS CONCRETE CONCRETE ANCHOR ® 1I2' MIN, TO GLASS ANCHOR 0 12. O,C. Y 16' D.G. _-__-- 1/2' MIN. ° l-I w PIN. 2" MIN. EQ _ 1 RJy 2' MIN. END CONN TION DETe11 0 °�R� a ©°R©°Rm°R®o A OR®+QORO +USE 1" OR 2" MAX, I IV-111EI)ORIQ11) - (AS APPUCABLE)x2'xl/B"xO'-2" ALUMINUM CUP ANGLE (8063-TG ALLOY) AT MIDHEICHT I W/(1)B10x1/2• S.M.S TO©k (2)1/4'C TAPCONS ANCHORSTO WALL AT1'O.C,AT EITHERSIDE OF QN )SEE DErAIL X FO 510E CONNECTIONTD TRACKS OR(q+OORO END CONNECTION DETAIL • REOL_M ONLY FOR SPANS GREATER MAN (2)#1 ®OR©OR©GR® OR(B+(DaRQ) . VIEW Y PLAN TAIL 'X F.B.C..(Non Nigh Velocity Hurricane Zone) a ' 4S�eG ., ..�a;, LTT � ®2DOJ INC. EASTERN METAL SUPPLY. f =� : 0 C O ,,, A" S � BERTHA HIVIM S ' TILLIT TESTING k ENGINEERING COMPANY 6]7! N.W. a91h. ■ ■ ■ American Shutter Systems Accordion Shu tter System f•$ SL, S1x. 3ca, 1x1 axa aARaals, RnwaA 311e° Phone : (3D9)871-1530 ,Fax : (305)671-1531 °-.4% txq°aaaal=m Aaacclation Inc. 4Z68 Westro0ds �, K oLseluxTlOx Drawn : SAS. 1 GATE °1a °A°/m }... R>Qi. EB-0006719 WALTER A nlLf Jr. Drive West Palm Beach, FL 33407 DATE: 7/13/OS P.E. SEALS Sff4L. DATE P. E FLORIDA Ua. f 4416' DRAWING' No j 05-196 P.E. MAXIMUM SHUTTER SPAN "L+" OR "L—" (ft.) INSTALLATIONS W/ OPPOSING EtiR R JATFc ONE HV LOCK & NO LOCKING RODS (SEE NOTE t) CONCRETE k WOOD uA+mwu INSTALLATIONS xsra+ LyG WALL MOUNTING k FLOOR/COUNG MOUNTING ' INCTA ATION I F— � —� CONCRETE & MANSORY Ell WALL 1, 2, 3 MOUNTING & 4 ]OR/CEILING 5, 6, 7 W, SW & MOUNTING & B 10W MHUTTER SPAN 'L+• OR 'L—' FOR S INTO WOOD SHALL RE LIMITED TO IGN LOAD, H CENTERMATE R3 MAY BE USEDAT ALL INSTALLATIONS. LOCKING SPECIFICATIONS AS INDICATED ON MANDATORY CONDITION #2SHEET a OF 1a 3 EC6INC. 1 :0Z " TILLIT TESTING & ENGINEERING - COMPANY Bass N.W. ]Bih. 6L. �y � �OPoDA _ p Phcnc (305]671-1a]�', J3168 (309)B71 —1931 HtT}' ,y� zc —mall: WI ... Q.°I,e°m EB-0006719 +�A' �. WALTER A. TILUT Jr, P. E• JDATE FL.RfDA Lic. 1 44167 ` NOTES . (1) L+: MAXIMUM ALLOWABLE SPAN FOR A GIVEN POSITIVE DESIGN LOAD. L—: MAX, ALLOWABLE SPAN FOR A GIVEN NEGATIVE DESIGN LOAD, (2) PROCEDURE TO DETERMINE MAXIMUM SPAN FOR WALL MOUNTINGS (TOP/BOTTOM) OR FLaOR/CEILING: GIVEN A POSITIVE DE51GN LOAD, DETERMINE MAXIMUM SPAN 'L+' FROM SCHEDULE. GIVEN'A NEGATIVE DESIGN LOAD, DETERMINE MAXIMUM 'L SPAN ' FROM SCHEDULE. FINAL MAXIMUM ALLOWABLE SPAN 15 EQUAL TO THE MINIMS DETERMINED SPAN BETWEEN •L+' AND °L_•• (3) PROCEDURE TO DETERMINE MAXIMUM SPAN FOR COMBINATIONS IN BETWEEN WALL MOUNTINGS W/ FLOOR/CEILING MOUNTINGS: FOR A GIVEN POSITIVE DESIGN LOAD: DETERMINE: L1+= MAX, SPAN FOR WALL MOUNTING INSTALLATIONS. IL += MAX, SPAN FOR FLOOR/CEILING MOUNTING NSTALLATIONS. FOR A GIVEN NEGATIVE DESIGN LOAD: OErERMINE: LI-- MAX- SPAN FOR WALL MOUNTING INSTALLATONS, TAL L7—= MAX, SPAN FOR FLOOR/CEILING MOUNTNG INSLATONS. FINAL MAXIMUM A-LOWABLE SPAN IS EQUAL TO THE MINIMUM BETWEEN 'U.,",•L3+•, 'L1_ AND •I,z_• . (4) GO TO ANCHOR SCHEDULE WITH FINAL MAXIMUM DETERGN MINE MAXIMUM ANCHOR SPACLE SPAN AND NEGATIVE ING. LOAD TO F.B,C,(Non High ,elocity Hurricane Zone) 0 2003 EASTERN METAL SUPPLY, INC, ►A■S■S■A■ BERTHA i VTm American Shuttar 5yatarne Accordion Shutter System A3310010t10n° 1n0. 4268 WBStroads Dr(Ye IN. N O15CIOPTION DATE Onnn JAM ' q° 01 m' 7iuA DATE; West POIm Beach, FL 33407 ,/„/DS 3 DRAWING No . 5 05-196 TMCOM ALL POD1�5 SOLID-SEr WEDDE-DOLT xaixue WALL MOUNTING 1 SPAN (n) 1" MO B/O HEAD �DED.11K Dmw LD ]0 IL:J 50 75 00 14 12 10 9 8 3�_0. 14 5 70 9 8 ]!t LESS 14 12 10 9 B 14 12 10 9 B 4'—D. 14 12 10 9 B 14 I2 10 9 B 14 12 10 9 B 5'-a' 14 i2 l0 s B 14 I2 10 9 e - POURED CONCRETE HV WALL MOUNTING 1 W/ HV POURED CONCRETE/CONCRETE BLOC L 7 2" (Max.)B/O HEADER SILL 2 WALL MOUNTING Q WALL MOUNTING 3 W/ C HV WALL MOUNTING 3 W HV "Ec.nvE oma LDAp 1p,0 1 ° Max. B 0 HEADER/ SILL i/1 2° fL1a:_m /n uren� "� - -- xmum DE96x L60 r..n ) * SEE ANCHOR SPECIFICATIONS ON SHEET 11 WALL MOUNTING 4 0®0I E DO©UAmINnvoMIENQIMIM1m1MIM ©WMEN®IMIMIMMIEN MINIMMImm[��xxx IOm�vEXmE INK11110 to ®m®Memon vv0o0o©vv0onns�©vam®m ===111111=ON a®®vm nvna©nvn � In inaeY®00So0avv0mOm®®Koamu�taoE"anvv o0i0vO�lev0�� vo ©�vv ovmvv 0mmvEu m®mvv©orami®miEanvvom®monrnvom®mn®v�avaa®mvvvovm®ro noiu©tm�vp®ommm0Ekai®mm�fffmv0Oma v�0Emaa■rv[0m��ev0v�iooi0vvaoov0vimmm®m�m�m®mmv0mmivvv0mlv®v®lYm EEN m®0®®vv�aas®moEll 10mnnmivvm®mtonnovmmmonvvv0ma�on0ovi0mm�vv©� ®a�mOa®m®mmmOlai vvv nm®e� a�mrnmveai�ae�mimmtn®Eavva�®¢an mma�on�e�iv®moivvvovn�mr�©vo�e�oi®m®onvvv Ean�v� mma' or�veanaimaaov®e�e�m®mtovnvoa�®®®vivvommran©ovummm�nnn� = m®�a®©vooim�mmror�vvom®rovnoivv®�■©e�vo�vomovonmvoia�mmonmov ®mm©®vvom®m�v®vvvmmmivneavvm®o®vvea�ammmvvveavm�®13 o®Avvv m®mm®vovo�®a�onvvom®Qannvvva�® mime®vvvvmminAvvva�®aavvivvommvoivoiveamv®ovoieavmm ® vvv®vov®oninv �ummove�v�■mimmvvivoivm®mov�avvo�®®vv�vvvaamm®vovvm®m IN ®®vovvvv0®mineavvAra®mtvvvoivm®v�a�avvea�®mvvvivvm®n�vvvv In mmnvvveavm®aaonovo . ®as®vm®voioveam�®mvoivoe�0mmv�aoivvmmovvvvv0maavve�vvimm0®vivivv vm®vvvo�ammovvvvv®®a�ov�avv®msavvv�av®mr�ovvvornmm®vvvo e�ooioivrv®®�a®oivv�®mvvvoviv©veavvvv�ovvvvonvmv mmmvvvovrom©�avvova�movvovie�mimn�vvoioi rn®®e�vvovm®mr�avvvo®®mvvvvva�ovvoveavm®®veaveav®®©veaoinv vvvve� v�®vvvomm®®v0�a�av®mmv�aivoio�®vvvvvoi��vvovtav�� a�mvaivvvvaa®��avvvva�®mvv�avvmv©vvvvv®®ovvve�vmmEa mimm�av�avommmivvvvv®mmivoioivvmmvvvvivvIu®®viviovramm®ivvvvv vvvvv mmonravovm®vvoivvv�®vovvvvv©oivvvvvoivvovovvori®vv�avv ®la�av�avovm®vivvvov0mvovvvivmnv�avvv�av®vvvvv�a0m®vvv ELT®OOvvvv[m®OVOvvval®vvvvOv�©vvv00v a�vvvo■vvoimovv�aovv0vovvvvv®ovivvv==Km ®vvvvivoiv"vvvovoiva�vv®v�a�aivrovvovivonvvvovivvvvmivv�vvvv mI®vOVOvv vvvvvv mvv�avvvomvvv�av�av�ovvv�avvmeaivvvvvv�av vr.aivv® �m�vvvvv vvvvvv vnvvivvo oiaa - ovvvrcwvivwv® _f 'r r {erF =s 1System West P61M Beach, ANWOR"`im Lima MAXIMUM D I N PR rwcaN M RE RA7TN(; (p,g f i AND CORR SPnnllr Ir. Au POINTS 50 0-srr FORA IV N MAx SH�TITER SPAN i)F41r'ILI I.IrnAT wmcE-BD T ANB A QH&,5PnNDING MOLINTIN lYP Fn`R QONCREI_F IueT•e11 A,.,.,.. A (SEE MOUNTINGS 5, 6, 7, k B ON SHEEP6). POURED CONCRETE CEILING MOUNTING 5 FLOOR MOUNTING 6 SPNI MAXIMUM(7 IffCATIVE °ESICN IpAO .T FLOOR MOUNTING 7 FLOOR MOUNTING B ID) xFrmvF nm.., J.-0- OR LES 4'-0' 6=0' Y-0. 9 -O" W-0' 16'-0' i�sMRa'aCSa O�ii�000000®®I�Q®Q©0�QQ®®ri Munn"�01m®0000001m®Q70�©®01 Mamvuuvotm®�vnvvet ®®mouo©v m®DDD�iOC 3ummm �m�ol®®ovm®mvvvvo®®r�o®©�aoia�®vv©©Eta f01�®�00000��0®���� am®0vlu�l©a �Monuvommmonne�o®KIM im uv�vov�®13 va>.mm�®®va M �mvvve�o®®m10 mv�vovai®nv©votolm�ol®�®ea0 l�l©ve�vBRIM ' ovv�®in M1 AM vvv®0101KOKO ' votv��v©n©vv®�®�®®lva mmm�lEA©oia mmvv�ototm®mivvvO,om®mnv©eavm®�®om=0 p0101m�0®®�0101®��©0©010 ®0©OQ�TOTIIITm®�00001� M0M®01p01a!®m000010®g ®�®®®eiialy�®©©®v00 Mmlvv�v1vvai®mvovvv m©DOOIO<KIM 191003�00 m®m00000 0®�®vvvv �m�v®vvo DODO 9®�©III��I�®i17E�0010�� �0©0®01001 �0®®DODO On ©Q©mvvvv�®mloraolvolm®mvlovvoaa®lumvvvo 0101010 �®�00000 ®Dtvo00ft1o00v1t1�o M®EO0m001010101i0®�0vDvOOvvv�oU3®ru©©�oQtoOO1tt00�if0o0t10v01�0�0i avv 0O 00aft10oo0 Mmvvmv movvv0 A[0===ototem®�vvvo,v�®®v�vvota�®vvotvvo EIMM ©0000v00®w=1= 1�i01C■[0®�pppp0W�Dv0101pp®®i1.010101010 AD00�00®m00000 ivMU®©0v001vE1�®000v0 mlrmF>01A0f�70 �MMQO�Sl7 �NDTES ON ANCHOR RFnIHR )�rNTS• p0 1REn QQNCRETE OR CONCRETE qI OCK SUBSTRATES 1. ANCHORS TO WALL SHALL BE AS FOLLOWS: (A) TO EOS LNG POURED CONCRETE: On. Pc . 3 us!) 1/4'1 TAPCON ANCHORS, AS MANUFACTURED eY I.T.W. RAMSET/ RED HEAD, 1/4.0 a 3/4' ALL Palm SOU° -SE ANCHORS ' S OISTRIBUTEU BY ALL POINTS SCRLIV, BOLT k SPECIALTY CC'PANY. - 1/4"0 WEDGE -BOLT ANCHORS AS MANUFACTURED BY POWERS FASTENING, INC. NOTES: Al) MINIMUM EMBEDMENT INTO POURED CONCRETE OF TAPCON ANCHORS IS 13/A' AND 2' FOR WEDGE -BOLT ANCHORS. A.2) MINIMUM EMBEDMENT OF 1/4'0 1 3/4' ALL POIITrs SOUO-SEr µCKaRS S CONCRETE. NO EMBEDMENT INTO STUCCO SHALL BE PERMITTED. 1/4' HALL BE 7/B' IH70 THE POURED SCREW USED SHALL 1 1/2' LONG MINIMUM SHOULD STUCCO MST.AND 1' MINIMUM h20 5.5. MACHINE FDfl WALLS WITH ND STUCCO. 0.]) .. CASE THAT PRECAST STONE, PRECAST CONCRETE PANELS. PAVERS DR AMP. VENEER BE FOUND ON THE .::.IXISTING.. WALL.,gq. FL. I .IINCHORS-:SHALL BELONG ENOUGH 70 REACH THE MAIN STRUCTURE BEHIND SAID WALL OR EIFS, ANCHORAGE THIS SHALL BE AS INOIGTED ON NOTES AI) & A2) ABOVE FOR Il STALLATICNS ON VINYL WALL DR EFS CONSULT T1115 ENGINEER. SIDING (B) TO ETOSTNG CONCRETE BLOCK WALL- - 1/4'o TAPCON ANCHORS, AS MANUFACTURED BY IT RAMSET/ RED HFAO. 1/' A 7/4' ALL P0IN15 SOUO-SET µCH0fl5 AS OISTRIBUTEO Ely ALL POINTS SCtiEW, BOLT & SPECW.TY COLIPANT. - 1/4b WEDGE -BOLT W/ 1/4'1 BLOCK -PLUG ANCHORS AS MANUFACTURED BY POWERS FASTENING, INC. NOTES; 8.1) MINIMUM EMBEDMENT INTO CONCRETE BLOCK OF TAPCON k WEDGE -BOLT ANCHORS, IS 1 1/4•. e.2) MINIMUM EMBEDMENT OF 1/4•A It 3/4' ALL POINTS SOLID -SET ANCHORS SHALL ea INTO 1HE CONCRETE BLOCH. NO EMBEDMENT INTO STUCCO SHALL LL E14TRELv ETIBEODm BE U. ' A USED SHALL BE 1 1/2' LONG NIMUM SHOULD STUCCO _ST. µD 1'PERNMINTOAUUEp1/4FOR WAp-20LLS CHINE SCREW WITH S.S. MA STUCCO, B.J) IN WE THAT PRECAST STONE PRECAST CONCRETE PANELS. PAVERS OR ANY VENEER BE FOUND ON THE EXISING' WALL OR FLOOR • ANCHORS SHALL -BE LONG ENOUGH TO REACH THE LIMN SIRUCNRE BENIN0 5A10 WALL FINISHES, ANCHORAGE SHALL BE AS INDICATED ON NOTES B.1) @ B.2) ABOVE FOR INSTALLATIONS ON VINYL SIDING OR EIFS CONSULT THIS ENGHEER. (C) ANCHORS SHALL BE INSTALLED FOLLOWING ALL OF THE RECOMMENDATIONS µD SPECIRGTIONS OF THE ANCHOR'S MANUFACTURER. (0) SEE SCHEDULE BELOW FOR EDGE DISTANCE (ED.) VERSUS SPACING ROACH FOR ANCHORS. DOE DISTANCE VFRCUa cpA IN FORA a MAIDMUM ANCHOR SPACINGS ARE VAUD FOR 3 1/2' i/4'0 TAPCON rANDno EDDO SET EDGE DISTANCE FOR AND WEDGE -BOLT FOR E. D. LESS THAN SPACIN THE ABVE OMENTIONED, REDUCE ANCHOR SPACING BY MULMPLYING SHOWN ON SCHEDULE BY THE FOLLOWING FACTORS, (NOTE ; MI . I-. D. FOR ALL POINT SOLID SET ANCHORS 13 3') REDUCED SPACING OHTAINEO USING FACTOR SHALL NOT BE LESS THAN MINIMUM SPACING INDICATED FOR EACH ANCHOR TYPE FACTOR ACTUAL F. D. WEDGE -BOLT 1/4"� TAPCON ._. SOLD SET D.e3 a.e3 O.fifi OJ O.fi6 _ O i� 0INe. ANS.S TA T-'. •- , ' ''- TILLIT -TESTING k ENGINEERING COMPANY W55 NEW. 361h. American Shuttsr Syefeme = �I Tr2h St:, St- 30. VIRGINIA GARDENS, TLGRDA 331EB Phan. ; (305)B71-I530., Fa. 1 (NTS)871-19]I a-maRUltAcaticol.cam A751CCIGtIOnT InC. 42fi9 Westr°ads Drive ''` 1• __ ` -0006719 WALTE EBA TILLR Jr. P. E.P.E. West Palm Beach, FL 33407 SEA AIIJIRI I?E/DATE �O� , CA uc 1 44167 R -C.(Non High Velocity Hurricane Zone) 32003 EASTERN METAL. SUPPLY,. INC. BERTHA mvTM Accordion Shutter System �• H OESCRWTON GATE 1 Omnn DRAWING NO. 0.9-196 B�TF . SOUTHERN PINE No. 2 W/ MIN. G=0.55, DOUGLAS FIR W/ MIN. G=0.50 SPRUCE PINE FIR NORTH MAXIMUM W/ MIN, G=0.43 SPRUCE PINE FIR SOUTH SPAN (R) WALL MOUNTINGS 1 W. 2W, 3W & 6W CEILING MOUNT BW FLO WALL MOUNTINGS W/ MIN. G=0.36 9WMOUNTINGSlow W 2W, 3W & 6W FLOORCEILINMOUNT a MOUNTINGS WALL MOUNTINGS CEILING MOUNT 8W NEGATIVE DESIGN LOAD (ps() . , NEGATIVE DESIGN LOAD (p,o - 'KEGM 9W & 10W �W' ZW+ 3W & 6W FLOOR MOUNTINGS 9W & low ° no teee 30 to 40 n 60 ,,, 75 .. 90 _ 05 _ 30 40 60 75 90 105 30 40 nmiGN LDAD' ,f (P ) fi0 75 an ne NEGATIVE DESIGN LOAD ( ttf) . ... __ _. NEGATIVE -DESIGN LOAD (Ps() NEGATIVE DESIGN LOAD (ps() _0" °F dQTES DN ANCHnR RFnlNaelarurs WOOD SUBSTRATE 1. ANCHORS TO WAIL, FLOOR OR SOUD WOOD SOFFIT SHALL BE AS FOLLOWS — 1/4'P TAPCON ANCHORS, AS MANUFACTURED By I I.T.W. SLOLDEX W/ MINIMUM EMBEDMENT AS INDICATED AT EACH SECTION ON SHEETS 13 do Ty ME EXCEPTION: SEE NOTE 2 BELOW. 2. ANCHORS TO HOLLOW CEILING SHALL BE AS PER .MOUNTING TYPE 7W, SHEET 1• AND SHALL CONSIST OF LAD SCREWS AS PER NOS 1997 SPECIFICATIONS. 3. SUBSTRATE SHALL CONSIST OF THE FOLLOWING: SOUTHERN PINE N.. 2 W/ G-0.55 (N.D.S) —DOUGIAS FIR W/ C-O.50 (N.O.S.) —SPRUCE PINE FIR NORTH W/ G-0.43 (ND.S.) —SPRUCE PINE FIR SOUTH W/ C-0.36 (N.O.S.) —MOT. 1/2' COX PLYWOOD (19BB APA) 4. ANCHORS- SHALL BE INSTALLED FOLLOWING ALL aF THE RECOMMENDATIONS AND SPECIFICATIONS of THE ANCHOR'S MANUFACTURER, zi� `' •', TILUT TESTING & ENGINEERING COMPANY i 2: '•� r: � ((�n�".5•,` s333 N.W. 300,, St., St,, 303. YW000A CAgpEN3, Phone • 71-15 ]]tee (Ja5---nTSJO . Fa, : (]05)e71-tell �—mon: LBt,eaoael.eom P.E. SEA �Ttl`RE/DATE WF ORIIDA d is P. . AmSmSmA7 American Shuster Systems Association, Inc. 4268 Westroads Drive West PQIM Beach, FL 33407 1/2" MIN. CDX PLYWOOD WALL MOUNTINGS 4W 8c 5W NEGATIVE DESIGN LOAD (p,f) F.B.C.(Non Nigh Velocity Hurricane Zone 0 2003 EASTERN METAL SUPPLY, INCBERTHA kv TM Accordion Shutter Svsten C. DRAWING No 05-196 -WALL FINISH r1/A•m rAPCON,/2' Mln. PENERunDN OF rHREaoEo AREA ITO EXISTING WOOD HEADER. (SEE SCHEDULE ON SHEET 12) F at ILLIL"Rt�'aIIJ x �GI J� 4 EXISTING MIN. 2"X4' WOOD EXISTING HEADER REQUIRED I II G 1' MIN. TO GLASS I ' 1W WALL CONNECTION AT TOP ING And I" MIN. CONr. SEPARAi1a 1 PLATE TO OLA:S 1 1 iz 1/4"D TAPCON W/ PENETRATION OF TNREAOEO AREA TO EXISTING WOOD HEADER. (SEE SCHEDULE ON SHEET 12) 1/a"m-20r3/a" S.S. MACHINE SCREWS 1 1/a"-20 NUTS O 12' O.C. 1' Ming D 0 n i LEX157TG M.N. .4WOOD I HEADER REQUIRED 1' MIN. EXISTING SEPARATIO GLS" To GLASS 2© WALL CONN rTlnu AT TOP 1 F 1 ( 11 I WOOD PLAATE 1 1 1 II III E F OR © REVO,' EO- I Q i Mln.—+ I//'m TAPCON W/ 1/2' Min. PENETRATION OF THREADED AREA INTO PLYW000. I 1/4'm-2' S.S. MACHINE (SEE SC14EDULE'ON SHEET 12) SCREWS W/ 1/4'-20 NUTS 1/2' MIN. COX PLYWOOD REO'D. 1 O 12" O.C. EXISTING MIN. 2'a4' STUDS a 16' O.C. MAX. REQ'D. PLYWOOD TO BE 1/2' MIN. COX—.(L". 1/C'm TA OCON W/ 1/2" Min. ATTACHED TO STUDS 1N ACCORDANCE WITH SECTION 2308 OF THE F.B,C. PENETRATION OF THREADED AREA INTO do THE S.B.C. (FOR NEW AND EXISTING CONSTRUCTION RESPECTNELY), PLYWOOD REpbw� (SEE SCHEDULE ON SHEET 12) 4W WALL CONNECTION AT BOTTOM @ WALL CONNECTION eT 90TTOM MEE: SHEET 3 FOR TYPICAL SHUTrR ASSEMBLY 2-MOUNTING SECTIONS CAN BE COMBINED IN ANY WAY TO SUIT ANY INSTALLATION. i yF'DR© I 11VO TAPCON W/ 1 1/2' M;n PENETRATION OF THREADED AREA TO EXISTING WOOD PLATE , (SEE SCHEDULE ON SHEET 12) • • 2'X4" OONT. SILL WAPLATE REO'O. 3W LL CONNEr_r1ntiT AT o01iOM EXISRNG T GVSS--I 0 I HE UTS (RATION OF (SEE SCHEDULE ON SHEET 12) --J PLATE 6W WALL CONNECTION AT BOTTOM C,(Non High Velocity Hurricane Zone' r'• 'St.p, 01003 EASTERN METAL SUPPLY, INC. L I L N C O INC. �■�■� •�' 13ERTHA HVTM Y ' TILLIT TESTING & ENGINEERING COMPANY Rw. 3su, Amerlean Shutter Systems Accordion ShutterYSysten I Zaf�e: s� sl. 3Ds, NRGpA rwDllts, �p101 33166 Phcnm ; (305)671-1630 . F..: (305)671-t631 ASSoclOtlon. Inc. 42fi8 Ev. N DESCRIPTION DATE I _ a-mvT: tilte..00W.cmm EB 000571D Westraads Drive West Palm Beach, r/u/w DATE: 7/13/0, = .E. SEALJSIGNPTUFiE/BATE-- Wu E T 4 P. FLORIDAFLOwDA �. A alR7 FL 33407 3 DRAWING N0 � 0$-196 11 0 6" D.C.s.la.s. O.0I I I OPEN HOLE Al E111-1/ STUD TO ACCEPT 5116*0 LAG AT CENTER OFSCREW TUBE. 1 , 1 • MIN. EDGE (IF AppUCAB 4".6" (Mln•) EXISTING WOOD BEAM REQUIRED. STRUCTURAL ADEQUACY OF EXISTING WOOD EXISRNC WOOD BEAM TO BE CERTIFIED By REGISTERED ENGINEER OR TRUSSES OR RAFTER O 24- ARCHITECT PRIOR TO SHUTTER INSTALLATION. REQUIRED EXING SOFFIT 3/4RMl--. THH, 1/4'D TAPCON W/ 1 1 l PENETRATION OF THREADM (6063-TS I'x4'a7/B' CONT. ALUM, TUBE ALLOY) W/ (3)S/16'm SCREWS ED AREA 70 E)Q—G WOOD BM. (SEE SCHEDULE ON SHEET 12) �OR OLAC 8 TO EACH USRAFTER OR TRS. LOCATE LAG SCREWS AT J MIDWIOTH OF EXISTING WOOD 'EMBER. (2' Mlm NOMINAL WIDTHOF T11AFA/pED•ARIn. FA VALIORFORN DESIGN DESIGN ATIONS WITH 72paf MAX, I SPAN. LOAD AND 9•_0• MAX THIS INSTALLATION IS ONLY EXISTING 1 VALID SPECIFIC FOR WOOD W/ NIN. CRAVTY OF O.SC AS GLASS) I DOUG[AS No. FIR OR SOUTHERN PINE 2, OR EQUAL. I I• j SST O I o FOLLOW CEILING MOUNTING INSTALLATION I 1MIN TEPARATi I 1 DOSSS I CLASS I 1/4'0 TAPCON W/I 1/2' Min. PENETRMTIONJ L-2' M1N.— OF THREADED AREA INTO WOOD DECK. (SEE SCHEDULE ON SHEET 12) 9© ELOOR CONNF+y= O ®S�FIT MOUNTING INSTALLATIO 'MOUNTING INSTALLATIO ' I 1' INN EXISTING I—SEPAAATION— CLASS\ E TO CUTS_ \11 I I I ALTERNA •I ANCHOR LOCATION I e/e' u6. SCREWS HEA0-3/4' HEX REQUIRED •(NO FINISHOAL,LO ALLOWED) SCREWS DTEK t O 12' m.e EDCE OF OECW �.�,• 2'x4' MIN, WOOD STUDS. (AS APPLICABLE) I' .. 1 1/a•m TAPCON / \ / ANCHOR O S. O.C. W/ 1 1/2' MIN. WALL FINISH'T ✓ PENETRATION INTO STUDS OR W/ MIN. EXISTING CLASS - I `f 1/2• PENETRX'ICN TO T•— f I/2' COX PLYWOOD IF NO STUDS Ezlsr. E0 I j /E 1" MIN. SEPARATION •i'�'.>:^? { -��' la: l+s`�).±''.`•`-i?.�: 1/2' MIN, COX TO CLASS PLYWOOD. I/Z- MIN. 810x1/2• S.M.S. SOR(TOR©OR ® IV O.0 OR OORO}® 1 . END COEND CONNECTION DETAI 1 W & 4W 270' MIN. WOOD STUDS REO� EXISTING CLASS 1/4'm TAPCON ANCHORS 1pw 1 1/2'MIN. PENETRATION O 12' O.C. 2 ,.AEI : LEDGE CF I/4•m DECK IF T.IPCON R. 1/2• ARn, PENETRATION APPLICABLE OF THREADED AREA INTO W000 DECK. 2' MIN, (SEE SCREOULE ON SHEET 12) 10 FLOOR CONN«xT1nA D.RmOB©OR� `WALLFINIS( OR OOR�� END CONNECTION D TAIL 5W IL E c o INS. A.S 1 1 . "•. ". •" TILLIT TESTING do ENGINEERING COMPANY 6""5 ILK 36IN 51, SL. 406, VR1GgM DMOENS• Phvnv 6 ■�■�■ American Shutter Syatema A7lOGIG}IOFII �1F"'., .. s (]05)871-1330 . Fax : (305)e 1-153, e-moll: NlmemOmW,c6m Inc. 4268 Westroods Drive P.E. SEAL/SIGNATURE/DATE WALTER86' MUT1s FLORIDAum. f 44167E West POIm Beach, FL. 33407 F•.C.(Non Nigh Velocity Hurricane Zone) m 2003 E'ASTHRN METAL SUPPLY,- INC. BERTHA HVTM Accordion. Shutter System EV• N OESCgIMEN 1 DATE' Drum 1q: JA,S. z DATE: 7 13/05 DRAWING No 05-1g6