Loading...
HomeMy WebLinkAboutNotice of Product CertificationNOTICE OF PRODUCT CERTIFICATION Company: JELD-WEN Certification No.: NI010116.01-11.1 Page 3 3737 Lakeport Boulevard Certification Date: 02/11/2010 Klamath Falls, OR 97601 Expiration Date: 12/31/2015 Revision Date: 06/19/2014 Product: Series "Energy Saver/Contour" Wood Edge 24 Gauge Steel Side -Hinged Doors w/ or w/o Side-Lites or w/ or w/o Transom (w/Wood Frame unless noted) Specifications: ASTM E283-04/E330-02/E331-00/AAMA 1304-02/ASTM E1886 -05/E1996 -05b To verify that the "Notice of Product Certification" is valid, please visit www.NAWCertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to .lain certification status. Please review and advise NAbII if anv corrections are required to t ds document. 1 National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: �� Inswing Glazed Design Water Test Missile Test Report Number Configuration or or Maximum Pressure Pressure Impact Drawing Number & Outswintr Ooaaue Size Pos/Neg (pal)_ Rated Comments X Its Opaque 37"x6'10" +55/-55 psf 0.0 psf Yes SJW2009-199/SJW2009-199 Addendum(061092014N Single Wind Zone 4 Missile Level D W-1685 Max Panel Sim: 3'0" x 67' Anchor Details: JW162009(1-16; X O/S Opaque + " 3'2" x 6 9 +55/-55 at P 0.0 psf Yes SJW2009-199 Single Wind Zone 4 162009(1-16) Missile Level D Anchor Details: JW XX US Opaque + ' + 6'2' x 6 10' +55/-55 psf 0.0 psf Yes SJW2009-199 Double Wind Ze4 Missile Level D Anchor Detail JW162009(I-16) XX O/S Opaque + + ' 6 2' x 6 9" +55/-55 psf P 0.0 psf Yes SJW2009-199 Double Wind Z e 4 Max Panel Sim: TO" x 67- Missile Level D Anchor Details: JW 162009(1-16) 1 National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: �� NOTICE OF PRODUCT CERTIFICATION Company: JELD-WEN , Certification No.: NI010116.02-R1 Page 4 3737 Lakeport Boulevard Certification Date: 02/11/2010 I(lamath Falls, OR 97601 Expiration Date: 12/31/2015 Revision Date: 06/19/2014 Product: Series "Energy Saver/Contour" Wood Edge 24 Gauge Steel Side -Hinged Doors w/ or w/o Side-Lites or w/ or w/o Transom (w/Wood Frame unless noted) Specifications: ASTM E283-04/E330-02/E331-00/AAMA 1304-02/ASTM E1886 -05/E1996 -05b To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if anv corrections are reouired to t As document. Inswing Glazed Design Water Test Missile Test Report Number Configuration or or Maximum Pressure Pressure Impact Drawing Number & Outswine Ooaane Size POSINev(nsf) Rated Comments OX/XO I/S or Door -Opaque 4'3" x 6'10" +551-55 psf 0.0 psf Door -Yes snv2009-200 Singlew/Sidelite O/S Sidelite-Glazed Wind Zone 4Sidelite Missile Level D No Mn Panel Size: 3'0"x6'T' Sidelite DLO: 7" x 63" Glazing: IG -1/8" Tempered Glass Anchor Details: JW 162009(1-16) OXO I/S or Door -Opaque 515" x 6'10" +55/-55 psf 0.0 psf Door -Yes SJW2009-200 Singlew/Sidelites O/S Sidelite-Glazed Wind Zone Missile Level D Sidelite-No Max Panel Size: 3'0"x6'T' Sidelite DLO: T' x 63" Glazing: IG -1/8" Tempered Glass Anchor Details:1W162009(1-16) O/X IIS or Door -Opaque • 3'2" x T11" +551-55 psf 0.0 psf Door -Yes SJW2009-200 Single w/1'ransom O/S Sidelite-Glazed Wind Zone 4 Missile Level D Sidelite-No Max Panel Size: 3'0" x 67' Sidelite DLO: T' x 63" Glazing. IG -1/8" Tempered Glass Anchor Details: 3W 162009(1-16) O/OXO IIS or Door -Opaque 5'5" x Tl 1" +551-55 psf 0.0 psf Door -Yes SJW2009-200 Single w/Sidelites O/S Sidelite-Glazed wind zone 4 Missile Level D Sidelite-No Max Panel Size: 3'0" x 67' Sidelite DLO: T' x 63" Glazing: IG -1/8" Tempered Glass & Transom Transom -Glazed Transom -No Anchor Details: JW 162009(1-16) National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: �104�