Loading...
HomeMy WebLinkAboutProduct Approval RECEIVED APR 22106 FILE COPY MIAMI-DADE MIAMI-DADE COUNTY o PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.2ov/eeonomv CertainTeed Corporation 1400 Union Meeting Road,P.O.Box 1100 Blue Bell,PA 19422-0761 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section.(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#13-0204.03 and consists of pages 1 through 16. The submitted documentation was reviewed by Alex Tigera. NtTA- o::�l'4=02-2'4:03` r MIAMI-DACE eourvrr Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 1 of 16 ROOFING SYSTEM APPROVAL Category Roofing Sub-Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -60 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description All Weather/Empire Base 36"x 65'10"; ASTM D 4601 Type Asphalt coated,fiberglass reinforced Sheet Roll weight: 86 lbs. 11 base sheet (2 squares) UL Type 15 Flex-I-GIasTM Base Sheet 36"x 98'9";Roll ASTM D 4601,Type Modified Bitumen coated fiberglass weight: 90 lbs. 11 base sheet. (3 squares) UL Type G2 Flex-I-GIasTM FR Base Sheet 39 3/$"x 50;Roll ASTM D 6163, Modified Bitumen coated fiberglass weight: 90 lbs. Grade S,Type I base sheet. (1.5 squares) Flintglas®Ply Sheet Type IV 36"x 1647";Roll ASTM D 2178 Type Fiberglass,asphalt impregnated ply or VI weight:40/55 lbs. N or VI sheet. (5 squares) UL Type GI Flintlastic STA 393/8,,x 33;Roll ASTM D 6222, Smooth surfaced APP Modified weight: 90 lbs. Grade S,Type II Bitumen membrane with non-woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA,GTA-FR 393/8,,x 33'3";Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G,Type H Bitumen membrane with non-woven (1 square) polyester mat reinforcement for torch application. Flintlastic GMS, 393/8,,x 34'2";Roll ASTM D 6164, Granule surfaced SBS Modified GMS Premium weight: 100/105 lbs. Grade G,Type H Bitumen membrane with non-woven (1 square) polyester mat reinforcement for mop application. Flintlastic FR, 393/8,,x 34'2";Roll ASTM D 6164, Fire resistant,granule surfaced SBS FR-P Premium weight: 105 lbs. Grade G,Type I Modified Bitumen Membrane with (1 square) non-woven polyester mat reinforcement for mop application. Flintlastic FR Cap Sheet 393/8"x 34'2";Roll ASTM D 6163, Fire resistant,granule surfaced SBS weight: 90 lbs. Grade G,Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. NOA No.:14-0224.03 MLAMi•oADE COUNTY Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 2 of 16 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic FR Cap T 39-3/8"x 34'2";Roll ASTM D6163 Granule surfaced SBS Modified weight: 81lbs. Bitumen membrane with fiberglass (1 square) mat reinforcement for torch application. Flintlastic FR Base T 39-3/8"x 33';Roll ASTM D6163 Modified Bitumen,coated fiberglass Weight: 81lbs. base sheet for torch application. (1.0 squares) Flintlastic FR Cap CoolStar 393/8,,x 34'2";Roll ASTM D 6163 Fire resistant,granule surfaced SBS weight: 90 lbs. Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. Flintlastic FR Cap T CoolStar 393/8,,x 34'2";Roll ASTM D 6163 Fire resistant,granule surfaced SBS weight: 90 lbs. Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. Flintlastic GTA,GTA-FR 39 3/g"x 33'3";Roll ASTM D 6222 Granule surfaced APP Modified CoolStar weight: 105 lbs. Bitumen membrane with non-woven (1 square) polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. Flintlastic GMS/GMS 393/8,,x 34'2";Roll ASTM D 6164 Granule surfaced SBS Modified Premium CoolStar weight: 1001105 lbs. Bitumen membrane with non-woven (1 square) polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Flintlastic FR-P/FR-P Premium 39 3/$"x 34'2";Roll ASTM D 6164 Fire resistant,granule surfaced SBS CoolStar weight: 105 lbs. Modified Bitumen Membrane with (1 square) non-woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Covered with reflective CoolStar Coating. Ultra Poly SMS 36"x 64'4" ASTM D 6164, Smooth surfaced SBS Modified (2 squares) Grade S,Type I Bitumen Membrane with non-woven polyester mat reinforcement for mop applications. NOA No.:14-0224.03 QMIAM-DADE COUNTY Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 3 of 16 G1asBaseTM Base Sheet 36"x 98'9";Roll ASTM D 4601 Asphalt coated,fiberglass base sheet. weight: 69 lbs. UL Type G2 (3 squares) PolySMS Base Sheet 393/8,,x 64'4";Roll ASTM D 4601, Modified Bitumen coated polyester weight: 90 lbs. Grade S,Type II base sheet. (2 squares) UL Type G2 Yosemite®Buffer Base Sheet 36"x 32'10";Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced weight: 90 lbs. ASTM D 4897 buffer sheet. (1 square) UL Type 30 Black Diamondrm Base Sheet 36"x.68'7";Roll ASTM D 1970 Self-adhering fiberglass reinforced weight: 78 lbs. modified bitumen base sheet (2 squares) APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) F1intBoard ISO Polyisocyanurate foam insulation CertainTeed Corporation ACFoam-11 Polyisocyanurate foam insulation Atlas Roofing Corporation High Density Wood Fiberboard Wood fiber insulation board Generic Perlite Insulation Perlite insulation board Generic DensDeck,DensDeck Prime Water resistant gypsum board Georgia Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels LLC ENRGY 3,ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation RMax Operating,LLC APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. None N/A None N/A NOA No.: 14-0224.03 MIAMI•DAD,COUNTY njol Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 4 of 16 EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date Factory Mutual Research Corp. FMRC 4470 J.I.3Y8A1.AM 03/23/96 FMRC 4470 J.I.OD3A3.AM 04/04/97 FMRC 4470 J.I.2DOAO.AM 12/23/98 FMRC 4470 J.I. 1D7A4.AM 11/09/98 Underwriters Laboratories,Inc. UL 790 R11656 01/11/13 United States Testing Company ASTM D 5147 97457-4 06/03/88 ASTM D 5147 97-457-2R 12/02/87 Momentum Technologies,Inc. ASTM D 4601 AX31G8D 09/05/08 ASTM D6164 AX31G8F 06/05/09 ASTM D6222 AX31G8G 06/05/09 ASTM D 3909/D 4897 AX3lG8C 09/05/08 TrinitylERD TAS 114(J) #3504.06.01-1 06/05/01 TAS 117(B) 3503.10.06 10/10/06 TAS 117(B) 06490.04.07-R1 06/27/07 TAS 114(IT) Letter 04/05/06 TAS 114 3533.01.06 01/06/06 TAS 114 3521.07.04 07/29/04 TAS 117(B)/ASTM D 6862 C8500SC.11.07 11/30/07 TAS 114 C8370.08.08 08/19/08 ASTM Physical Properties C10080.09.08-R4 03/25/10 ASTM D6164/D4798 C31410.01.11-2 01/10/11 ASTM D4601 C40050.09.12-1 09/28/12 ASTM D1970 C40050.09.12-2 09/28/12 ASTM D5147/D4798 C31410.10.10-R1 11/01/12 ASTM D5147/D4798 C31410.01.11-1-R1 11/01/12 ASTM D4798 C31410.01.11-2A-Rl 02/21/13 ASTM D4798 C31410.12.13 12/05/13 ASTM D6222 C40050.12.13 12/05/13 PRI Construction Materials ASTM D6163 CTC-032-02-01 01/22/08 Technologies LLC ASTM D6163 CTC-066-02-01 08/09/11 ASTM D6164 CTC-068-02-01 08/09/11 ASTM D6222 CTC-070-02-01 08/09/11 ASTM D6164/D4798 CTC-093-02-01 08/09/11 ASTM D2178 CTC-122-02-01 03/13/12 ASTM D2178 CTC-123-02-01 03/13/12 ASTM D4601 -CTC-127-02-01 03/13/12 ASTM D6163 CTC-128-02-01 06/11/12 ASTM D6163 CTC-129-02-01 06/11/12 ASTM D6164 CTC-132-02-01 06/11/12 ASTM D6164 CTC-162-02-01 05/09/13 ASTM D6164 CTC-161-02-01 05/09/13 ASTM D6162 CTC-183-02-01 10/02/13 ASTM D6164 CTC-190-02-01 12/02/13 NOA No.: 14-0224.03 QMIAMERounan Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 5 of 16 APPROVED ASSEMBLIES.- Membrane SSEMBLIES:Membrane Type: APP Modified Deck Type 1I: Wood,Insulated Deck Description: 19/32°or greater plywood or wood plank System Type A(1): Anchor sheet mechanically fastened;all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet,Glas Base or Flintglas Premium Ply Sheet(Type VI)mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4"and fastened with 11 ga.annular ring shank nails and approved tin caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 Density/fe ACFoam-II,Multi-Max FA-3,ENRGY 3,FlintBoard ISO,H-Shield Minimum 1.5"thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of Black Diamond Base Sheet self-adhered. Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas Base,Flex-I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet self-adhered or Flintlastic STA torch adhered. Membrane: Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR or GTA-FR CoolStar torch adhered to base or ply sheet. Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA. Install one of the following: 1. 400-1b./sq.gravel or 300-Ib./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,F1intCoat A- 150,APOC#212 Fibrated Aluminum Roof Coating at an application rate of 1 Y2 gal./sq. Maximum Design -52.5 psf(See General Limitation#7) Pressure: NOA No.:14-0224.03 MIAMI-DAne couNTY Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 6 of 16 Membrane Type: SBS Modified Deck Type 1I: Wood,Insulated Deck Description: 19/32' or greater plywood or wood plank System Type A(2): Anchor sheet mechanically fastened;all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet,Glas Base or Flintglas Premium Ply Sheet(Type VI)mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4"and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 Densi"2. ACFoam-II,ENRGY 3,ENRGY 3 25 PSI,FlintBoard ISO,H-Shield Minimum 1.5"thick N/A N/A Approved Perlite Minimum%"thick N/A N/A Approved High Density Wood Fiberboard Minimum%11 thick N/A N/A DensDeck,DensDeck Prime Minimum%"thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas Base,Flex- I Glas FR Base or Poly SMS base adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq Ply Sheet: (Optional)One or more plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet (Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet(for use with a torched cap sheet only)self-adhered. COUNTY NOA No.: 14-0224.03 MIAMI•DADE � Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 7 of 16 Membrane: One ply of Flintlastic GMS,Flintlastic GMS CoolStar,Flintlastic Premium GMS,Flintlastic Premium GMS CoolStar, Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR- P,Flintlastic Premium FR-P CoolStar,Flintlastic FR Cap sheet,Flintlastic FR Cap Sheet CoolStar adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq.or Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar torch adhered to base/ply sheet. Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA. Install one of the following: 1. 4004b./sq. gravel or 300-1b./sq.slag in a flood coat of approved mopping asphalt at an application rate of 601b./sq. 2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,F1intCoat A-150,APOC#212 Fibrated Aluminum Roof Coating at an application rate of 1 %2 gal./sq. Maximum Design Pressure: -52.5 psf(See General Limitation#7) NOA No.: 14-0224.03 MIAMI•DADEcouNTY Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 8 of 16 Membrane Type: APP Modified Deck Type 1I: Wood,Insulated Deck Description: Minimum 19/32"thick plywood attached using approved nails spaced 4"o.c.at wood joists spaced maximum 24"o.c. System Type A(3): Anchor sheet mechanically fastened;all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet,G1asBase or Flintglas Premium Ply Sheet(Type VI) mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4"and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 ACFoam-II,Multi-Max FA-3,ENRGY 3,FlintBoard ISO,H-Shield Minimum 1.5"thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base: One ply of Black Diamond Base Sheet self-adhered. Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas Base,Flex-I Glas FR Base or Poly SMS base or one or more plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet self-adhered or Flintlastic STA torch adhered. Membrane: Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR or GTA-FR CoolStar torch adhered to base or ply sheet. Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA. Install one of the following: 1. 400-1b./sq.gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,FlintCoat A-150,APOC#212 Fibrated Aluminum Roof Coating at an application rate of 1 %z gal./sq. Maximum Design Pressure: -60 psf. (See General Limitation#7) in NOA No.:14-0224.03 MIAMI-DADE COUNTY Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 9 of 16 Membrane Type: SBS Modified Deck Type 1I: Wood,Insulated Deck Description: Minimum 19/32"thick plywood attached using approved nails spaced 4"o.c.at wood joists spaced maximum 24"o.c. System Type A(4): Anchor sheet mechanically fastened;all layer of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet,G1asBase or Flintglas Premium Ply Sheet(Type VI) mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4"and fastened with 11 ga.annular ring shank nails and approved tin caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Fastener Table 3 Density/fe ACFoam-II,ENRGY 3,ENRGY 3 25 PSI,FlintBoard ISO,H-Shield Minimum 1.5"thick N/A N/A Approved Perlite Minimum 3/4"thick N/A N/A Approved High Density Wood Fiberboard Minimum%"thick N/A N/A DensDeck,DensDeck Prime Minimum%"thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas Base,Flex- I Glas FR Base or Poly SMS base adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq Ply Sheet: (Optional)One or more plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet (Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet(for use with a torched cap sheet only)self-adhered. NOA No.: 14-0224.03 MIAMI•DAD;COUNTY Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 10 of 16 Membrane: One ply of Flintlastic GMS,Flintlastic GMS CoolStar,Flintlastic Premium GMS,Flintlastic Premium GMS CoolStar, Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR- P,Flintlastic Premium FR-P CoolStar,Flintlastic FR Cap sheet,Flintlastic FR Cap Sheet CoolStar adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq.or Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar torch adhered to base/ply sheet. Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA. Install one of the following: 1. 400-1b./sq.gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 601b./sq. 2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,F1intCoat A-150,APOC#212 Fibrated Aluminum Roof Coating at an application rate of 1 %2 gal./sq. Maximum Design Pressure: -60 psf. (See General Limitation#7) MIAMI•DADE COUNTY NOA No.: 14-0224.03 � Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 11 of 16 Membrane Type: APP Modified Deck Type 1I: Wood,Non-Insulated Deck Description: 19/32" or greater plywood or wood plank System Type E(1): Base sheet mechanically fastened. All General and System Limitations apply. ,Base_Sheet;=,,:.Tne-pl o f1*Weath-er/Empiro_BaseySheel,Glas Base or Flintglas Premium Ply Sheet(Type VI)mechanically attached as detailed below. sta ening: Base sheet shall be lapped 4"and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas Base,Flex-I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet self-adhered or Flintlastic STA torch adhered. Me_R] rani': . F]mtlast G� ,,A,Flintlastic GTA CoolStar,Flintlastic GTA-FR or GTA-FR CoolStar torch a ere_`to ba a ply sheet. Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA. Install one of the following: 1. 400-Ib./sq. gravel or 300-1b./sq.slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,FlintCoat A-150,APOC#212 Fibrated Aluminum Roof Coating at an application rate of 1 '/Z gal./sq Maximum Design Pressure: -52.5 psf. (See General Limitation#7) UA"1�Jo.r14�0224:03 QM1AMM1-DMADEMC0=UNTY Expiration-Date:-06/19/18 Approval=Date:-04/10/14-7Page72_of 16 Membrane Type: SBS Modified Deck Type 1I: Wood,Non-Insulated Deck Description: 19/32" or greater plywood or wood plank System Type E(2): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet,Glas Base or Flintglas Premium Ply Sheet(Type VI)mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4"and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas Base,Flex-I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet self-adhered or Flintlastic STA torch adhered. Membrane: One ply of Flintlastic GMS,Flintlastic GMS CoolStar,Flintlastic Premium GMS,Flintlastic Premium GMS CoolStar,Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar,Flintlastic FR Cap Sheet,Flintlastic FR Cap Sheet CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq.or Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar torch adhered to ply sheet. Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA. Install one of the following: 1. 400-1b./sq.gravel or 300-Ib./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,F1intCoat A-150,APOC#212 Fibrated Aluminum Roof Coating at an application rate of 1 %Z gal./sq Maximum Design Pressure: -52.5 psf. (See General Limitation#7) NOA No.:14-0224.03 MIAMI-DAoe COUNTY Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 13 of 16 Membrane Type: APP Modified Deck Type 1I: Wood,Non-Insulated Deck Description: Minimum 19/32"thick plywood attached using approved nails spaced 4"o.c.at wood joists spaced maximum 24"o.c System Type E(3): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet,G1asBase or Flintglas Premium Ply Sheet(Type VI) mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4"and fastened with 11 ga.annular ring shank nails and approved tin caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas Base,Flex-I Glas FR Base or Poly SMS or one or more Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.or one ply of Black Diamond Base Sheet self-adhered or Flintlastic STA torch adhered. Membrane: Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR or GTA-FR CoolStar torch adhered to base/ply sheet. Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA. Install one of the following: 1. 400-1b./sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 601b./sq. 2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,FlintCoat A-150,APOC#212 Fibrated Aluminum Roof Coating at an application rate of 1 %gal./sq Maximum Design Pressure: -60 psf. (See General Limitation#7) NOA No.: 14-0224.03 IIAMI•DADE COUNTY Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 14 of 16 Membrane Type: SBS Modified Deck Type 1I: Wood,Non-Insulated Deck Description: Minimum 19/32"thick plywood attached using approved nails spaced 4"o.c. at wood joists spaced maximum 24"o.c System Type E(4): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet,GlasBase or Flintglas Premium Ply Sheet(Type VI) mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4"and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: (Optional)One ply of All Weather/Empire Base Sheet,Ultra Poly SMS,Glas Base,Flex-I Glas Base,Flex-I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet(Type VI)adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet self-adhered or Flintlastic STA torch adhered. Membrane: One ply of Flintlastic GMS,Flintlastic GMS CoolStar,Flintlastic Premium GMS,Flintlastic Premium GMS CoolStar,Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar,Flintlastic FR Cap Sheet,Flintlastic FR Cap Sheet CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq.or Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar torch adhered to ply sheet. Surfacing: (Optional)Any coating,listed below,used as a surfacing,must be listed within a current NOA. Install one of the following: 1. 400-1b./sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak(#97 AF)Fibrated Aluminum Roof Coating,F1intCoat A-150,APOC#212 Fibrated Aluminum Roof Coating at an application rate of 1 '/i gal./sq Maximum Design Pressure: -60 psf.(See General Limitation#7) NOA No.: 14-0224.03 MIAMI•DADE COUNTY Expiration Date: 06/19/18 �Igjmqxv� Approval Date: 04/10/14 Page 15 of 16 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below 275 lbf.insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing, prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters,and comers).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.:14-0224.03 MiAMi•oaoE CouNTY Expiration Date: 06/19/18 Approval Date: 04/10/14 Page 16 of 16