HomeMy WebLinkAboutProduct Approval HOME IMPROVEMENT CONTRACT
PLEASE READ THIS CONTRACT
ROOFING SPECIFICATION SHEET
DESCRIPTION OF WORK
Customer Name: M/M mark bond Date: 4/14/2015
Branch Name: Miami Job#: 8186534
Sales Consultant: Paul Stahl
LINE-
Hurricane Mitigation=No, Premium 10 Year,Atlas
GlassMaster,Atlas GlassMaster=Silver White
Number of Squares(excluding Low Slope):=13.33,
Number of Flat Roof Squares=0 Flashing
Misc Linear Ft of Drip Edge to be Installed=170, Color of Drip
Rigid Ridge Vent=Yes,Linear Ft Ridge Vent to be Edge to be Installed=White
Installed=36, Rigid Ridge Vent-Color=Black, Off Ridge
Vent=No, Replace Fascia=No, Hurricane Mitigation
Inspection=No
Pricing Includes:
Drip Edge-in 10ft Sgmts
Shingle Removal and Application.
SPEC>(AL CONSIDERATIONS t ,.
PRE EXISTING CONDITIONS 3
r
ADDITIONAL CHARGES
t
If rotted or damaged wood is discovered AFTER removing the existing roofing,or could -fled at the time of sale,there-will
be an additional charge of$ 72 per sheet of 4x8 sheathing and/or$ 6 per linear ft.of ensional lumber for decking.,
N :�
If additional layers of roofing are discovered AFTER removing the fust layer,or could not be identified at the time ak s e,(here w#l,,Be
an additional charge per square to remove each additional layer based on product to be removed: v..
$ 21 for composition shingles,$ 55 for wood shingles.Low or flat roofs will be priced on a per job basis bast ons
complexity. ��
CONTRACT"- MOUNT - ;
$S,v27 00' F
06/17/14-SA Page 7 of 8
Florida Building Code Online Page 1 of 2
tF
Florit
Deeparnenttf BCIS Home Log In { User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search
Bus ines � �
Product ApprovalP' [Q J'd: aI
USER:Public User
Prodret AM.royal Menu>Product or Aonlicatim Search>Anocation list>Application Detail
...,'..
FL# FL9792-R5
21 != Application Type Revision
Code Version 2010
Application Status Approved
Comments
Archived
Product Manufacturer Atlas Roofing Corporation
Address/Phone/Email 2000 RiverEdge Parkway
Suite 800
Atlanta, GA 30328
(770) 933-4477
etodd@atlasroofi ng.com
Authorized Signature Ed Todd
etoddCa)atlasroofl ng.com
Technical Representative Ed Todd
Address/Phone/Email 2000 Riveredge Pkwy
Suite 800
Atlanta, GA 30328
(770) 933-4477
etodd@atlasroofi ng.com
Quality Assurance Representative
Address/Phone/Email
Category (Asphalt
ofing
Subcategory Shingles
Compliance Method Evaluation Report from a Florida Register hit t or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received l*40
Florida Engineer or Architect Name who Robert Nieminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity LIL LLC
Quality Assurance Contract Expiration Date 09/10/2013
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received 0
Certificate of Independence FL9792 R5 COI Trinity ERD CI -Niemilien.Ddf
Referenced Standard and Year(of Standard) Standard
ASTM D3161, Class F
ASTM D3462 0 0
ASTM D7158, Class H
TAS 100yj1
TAS 107 1 m
Equivalence of Product Standards
Certified By
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs2cHSPuWTxiRW... 6/12/2013
Florida Building Code Online Page 2 of 2
f
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/16/2012
Date Validated 10/19/2012
Date Pending FBC Approval 10/31/2012
Date Approved 12/04/2012
� v of Products
FL# Model,Number or Name IDescription
9792.1 Atlas Asphalt Roof Shin les Fiberglass reinforced asphalt roof shingles
Limas of Use Installation Instructions
Approved for use in HVHZ:Yes FI-9792 R5 11 er101520121FINAL ATLAS FI-9792-
Approved for use outside HVHZ:Yes. R5 Asphalt Shingles.odf
( Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use and ER Evaluation Reports
Section 6 for Installation Requirements. FL9792 R5 AE er10152012FINAL ATLAS FL9792-
R5 Asp alt Shin lace sTndf
Created by Independent Third Party. Yes
Back Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone,850-487-1824
The State of Florida is an AA/EEO employer.Convriaht 2007-2010 State of Florida.::Privaev Statement::Accessibility tat.m n ::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant
to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email
address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you
do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if
you are a licensee under Chapter 455,F.S.,please click bgrg.
Product Approval Accepts: - -
.
SCCLtT'itt•.3i'.i>C7k.[t'S"
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgs2cHSPuVVTxiRW... 6/12/2013
EXTERIOR. RESEARCH & DESIGN, LLC.
Certificate of Authorization#9503
'�QTRINI-ff
353 CHRISTIAN STREET, UNIT #13
ERD OXFORD, CT 06478
PHONE: (203) 262-9245
FAX:_(203) 262-9243
EVALUATION REPORT
Atlas Roofing Corporation Evaluation Report Al 2620.12.08-114
2,060 River Edge Parkway FL9792-115
Atlanta, GA 30328 Date of Issuance: 12/18/2008
Revision 4: 10/15/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: Atlas Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein. For HVHZ, shingles shall be labeled in accordance with Miami-
Dade requirements.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. Trinity ERD requires a complete review of this Evaluation-
Report
valuation-Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by _
the manufacturer or its distributors and- shall be available for inspection at' the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
- ' The facsimile seal appearing was authorized
:-:�; ..�4sa,��4',.? by Robert Nieminen,P.E.on 10/15/2012
This does not serve as an electronically signed
�. document. Signed,sealed
Robert J.M. Nieminen, P.E.
;w�Ar ,"J ,�` transmitted to the Product Approval Administrator and
Florida Registration No. 59166, Florida DCA ANE1983 to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company.manufacturing or
distributing products it evaluates. '
2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
I
TRTY
ER,D.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Atlas Asphalt Roof Shingles, as produced Atlas Roofing Corporation, have
demonstrated compliance with the following sections of the Florida Building Code and Florida Building
Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007
1507.2.7.1, R905.2,6.1 Wind Resistance ASTM D3161, Class F 2006
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2007
1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995
1523.6.5.1 Wind Driven Rain TAS 100 1995
3. REFERENCES:
Entity Examination Reference Date.
ATI (TST 1558) Wind Driven Rain TAS 100 01/30/1998
PRI (TST 5878) Wind Driven Rain TAS 100 07/09/2003
PRI (TST 5878) Physical Properties ATL-021-02-01 04/08/2005
PRI (TST 5878) Wind Driven Rain TAS 100 01/31 /2005
PRI (TST 5878) Wind Driven Rain ATL-020-02-01 02/03/2005
PRI (TST 5878) Physical Properties ASTM D3462 05/02/2005
PRI (TST 5878) Physical Properties. ATL-035-02-01 10/12/2007
PRI (TST 5878) Wind Driven Rain ATL-036-02-01, 02/28/2008
PRI (TST 5878) Wind Resistance ATL-054-02-01 04/29/2010
PRI (TST 5878) Wind Driven Rain ATL-053-02-01 05/03/2010 .
PRI (TST 5878) Physical Properties ATL-055-02-01 05/12/2010
PRI (TST 5878) Wind Resistance ATL-054-02-01 04/29/2010
PRI (TST 5878) Wind Resistance , ATL-056-02-01 06/21/2010
PRI (TST 5878). Wind Driven Rain ATL-020-02-01; Addendum 09/09/2011
PRI (TST 5878) Physical Properties ATL-021-02-01; Addendum 09/09%2011
PRI (TST 5878) Wind Resistance ATL-079-02-01 02/17/2012
PRI (TST 5878) Wind Driven Rain ATL-081-02-01 02/17/2012
PRI (TST 5878) Wind Resistance ATL-081-02-02 02/17/2012
UL (TST 1740) -Wind Resistance TAS 107 06/09/1999
UL (TST 1740) Wind Resistance 02NK6989 03/04/2002
UL (TST 1740) Wind Resistance 05CA03322 05/06/2005
UL (TST 1740) Wind Resistance TAS 107 09/15/2005
UL (TST 1740) Wind Resistance TAS 107 /.02NK6989 03/04/2002
UL (TST 1740) Physical Properties ASTM D3462/R4052 09/17/2002
UL (TST 1740) Physical Properties ASTM D3462/R4052 03/02/2006
UL (TST 1740) Wind Resistance 07CA26303 08/31/2007
UL (TST 1740) Physical Properties ASTM D3462/ R4052 11/14/2007
UL (TST 1740) Wind Classification 07NK22068 04/29/2008
Miami-Dade (CER 1592) HVHZ Compliance 07-0927.06 04/10/2008
Miami-Dade (CER 1592) HVHZ Compliance 09-0114.01 03/11/2009
Miami-Dade (CER 1592) HVHZ Compliance 10-0519.03 08/04/2010
Miami-Dade (CER 1592) HVHZ Compliance 10-0519.04 08/04/2010
Atlas Roofing Trade Name Documentation Trade Name Documentation 02/03/2012
Atlas Roofing Trade Name Documentation Trade Name Documentation 02/07/2012
Atlas Roofing Trade Name Documentation Trade Name Documentation '02/23/2012
UL LLC(QUA 9625) Quality Control Inspection Report; R4052 01/18/2012
UL LLC(QUA 9625) Quality Control Inspection Report; R4052 09/10/2012
Exterior Research and Design, LLC. Evaluation Report All 2620.12.08-R4
Certificate of Authorization#9503 FL9792-R5
Revision 4: 10/15/2012
Page 2 of 5
-liTRINITYI ERD
4. PRODUCT DESCRIPTION:
4.1 GlassMaster® 25, GlassMaster® 30, Tough-Glass 20 and StormMaster® Slate are fiberglass
reinforced, 3-tab asphalt roof shingles.
4.2 Pinnacle®, Pinnacle® 35, Pinnacle® Lifetime, Pinnacle® Lifetime with ScotchgardT'", Pinnacle®
HP, and StormMaster® Shake with Scotchgard7m (formerly StormMaster® LM) are fiberglass
reinforced, laminated asphalt roof shingles.
5. LIMITATIONS:
5.1 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.2 Wind Classification (non-HVHZ):
5.2.1 GlassMaster® 25, GlassMaster® 30, Tough-Glass 20, StormMaster® Slate, Pinnacle® HP and
StormMaster® Shake with ScotchgarclTM (formerly-StormMaster® LM) shingles noted herein
have been tested in accordance with FBC Table 1507.2.7.1 and R905.2.6.1 to UL3161, Class
F, indicating the shingles are acceptable for us in all wind zones up to Vasa = 150 mph (Vint =
194 mph). Refer to Section 6.1 for installation requirements to meet this wind rating.
5.2.2 GlassMaster® 25, GlassMaster® 30, Tough-Glass 20, StormMaster® Slate, Pinnacle®,
Pinnacle® 35, Pinnacle® Lifetime,'Pinnaclee Lifetime with Scotchgard TM, StormMaster® Shake
with ScotchgardTM (formerly StormMaster® LM) have been tested / examined in accordance
with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D7158, Class H, indicating the shingles
are acceptable for us in all wind zones up to Vasd = 150 mph (V"it = 194 mph). Refer to
Section 6.1 for installation requirements to meet this wind rating.
5.2.2.1 Classification by ASTM D7158 applies to exposure category B or C and a building height of .
60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data.specific to each shingle.
5.3 Wind Resistance (HVHZ):
5.3.1 GlassMaster® 25, GlassMaster® 30, Tough-Glass 20, StormMaster® Slate, Pinnacle®,
Pinnacle® 35, Pinnacle® Lifetime, Pinnacle® Lifetime with ScotchgardTM, Pinnacle® HP and
StormMaster® Shake with ScotchgardT'" (formerly StormMaster LM) have been tested /
examined in accordance with TAS 107 and TAS 100, and are suitable for use in HVHZ. Refer
to.Section 6.2 for installation requirements for HVHZ.
5.3.2 Shall not be installed on roof mean heights in excess of 33 feet.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Non-HVHZ:
6.1.1 Underlayment:
6.1.1.1 Underlayment shall be acceptable to Atlas Roofing Corporation and shall hold current Florida
Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.1.2 Asphalt Shingles:
Exterior Research and Design, LLC. Evaluation Report Al 2620.12.08-R4
Certificate of Authorization#9503 FL9792-R5
Revision 4: 10/15/2012
Page 3 of 5
TRINITY ERD.
6.1.2.1 Installation of asphalt shingles shall comply with the manufacturer's . current published
instructions, using minimum four (4) nails per shingle in accordance with the requirements of
FBC Sections 1507.2 or R905:2.
6.1.2.2 Nails and nail placement shall be in accordance with manufacturer's current published
installation instructions, but not less than. FBC 1507.2.6 or R905.2.5. Staples are not
permitted.
6.1.2.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact Atlas Roofing for details.
6.2 HVHZ:
6.2.1 Shingles and flashings shall be installed in accordance with RAS 115.
6.2.2 The manufacturer shall provide clearly written -application instructions to be used in
conjunction with RAS 115. Should a particular section of the. installation instructions conflict
with RAS 115, the requirements of RAS 115 prevail.
6.2.3 Nail placement requirements are as detailed below.
6.2.3.1 GlassMaster® 25, GlassMaster® 30, Tough-Glass 20:
Balls
� 1{p
12" 12
6.2.3.2 Storm Master® Slate:
19 Z'
8-z"
1" 7_s.,
16 2 8
I
22-IJ"
Exterior Research and Design, LLC. Evaluation Report Al 2620.12.08-R4
Certificate of Authorization#9503 FL9792-R5
Revision 4: 10/15/2012
Page 4 of 5
TRINITYER.D.
6.2.3.3 Pinnacle®, Pinnacle° 35, Pinnacle° Lifetime, Pinnacle Lifetime® with Scotchgard TM,
StormMaster® Shake with Scotchgard"I (formerly StormMaster LM):
6.2.3.4 Pinnacle® HP:
Nailthraughthetf
dou6lelayerarea
I
i Irr Exposure,
I I ,` i :.Exposiciori
17 ,.
75/87—1
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and
logo of the Accredited Quality Assurance Agency noted herein. For HVHZ, shingles shall be
labeled in accordance with HVHZ requirements.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507:2.7.1 /•R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the noted'QA agency for information on product locations covered by QA procedures
10. QUALITY ASSURANCE ENTITY:
UL LLC - QUA9625 (T) 847-664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report Al 2620.12.08-R4
Certificate ofAuthorization#9503 - FL9792-R5
Revision 4: 10/15/2012
Page 5 of 5
Florida Building Code Online Page 1 of 2
7777777777-717
tit
t
BCIS Home 1 Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map4 Links 1 Search
Busines��,� :
ser
Profess nab
jr(j-'. Pro. uctuApp�oval
Regulation
} I.-. Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# - FL6267-R6
Application Type Revision
Code Version 2010 .
Application Status Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1361 Alps Road
Wayne,NJ 07470
(973)872-4421
lindareith@trinityerd.com
Authorized Signature Beth McSorley
lindareith@trinityerd.com
Technical Representative Beth McSorley
Address/Phone/Email 1361 Alps Road-Bldg 11-1
Wayne,NJ 07470
(973)872-4421
BMcSorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
s] Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who Robert Nieminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/01/2014
Validated By John W. Knezevich,PE
._ Validation Checklist Hardcopy Received
Certificate of Independence FL6267 R6 COI Trinity ERD CI-Nieminen-2013.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM G155 2005
TAS 100(A) 1995
TAS 110 2000
Equivalence of Product Standards
Certified By
http://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqu02YBW7bM8MZA... 8/23/2013
Florida Building Code Online Page 2 of 2
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/21/2013
Date Validated 06/24/2013
Date Pending FBC Approval 07/01/2013
Date Approved 08/23/2013
----- ....._._...._.__.
..................... -.---............................ ---.._.._......._......-----.............. --
Summary of Products
--IlModel,Number or Name Description
6267.1 GAF Roof Ventilation Products Low profile roof ridge vents
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL6267 R6 II er061913FINAL GAF Ventilation FL6267-
Approved for use outside HVHZ:Yes R6.Ddf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Use. Evaluation Reports
FL6267 R6 AE er061913FINAL GAF Ventilation FL6267
-
R6
Created by Independent Third Party:Yes
. Back Next '
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2010 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not '
send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. -
*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department
with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public
record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.
_ To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
ECGeck .-_
security ntt'rstics' .
http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu02YBW7bM8MZA... 8/23/2013
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization#9503
353 CHRISTIAN STREET, UNIT #13
ERD OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.02.06-R6
1361 Alps Road, Building 7-3 FL6267-116
Wayne, NJ 07470 Date of Issuance: 02/28/2006
Revision 6: 06/19/2013
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections referenced herein.
DESCRIPTION: GAF Roof Ventilation Products
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes; or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle. -
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared.by:
p' •• '` The facsimile seal appearing was authorized
by Robert Nieminen,P.E.on 06/19/2013
�..F•y-^•,; r This does.not serve as an electronically signed
Robert J.M. Nieminen P.E. °�;Fs;: document. Signed,sealed hardcopies have been
x iO 4�.`•'" transmitted to the Product Approval Administrator and
Florida Registration No. 59166, Florida DCA ANE1983 to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
r
QTRINERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: GAF Roof Ventilation Products, as produced by GAF, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with
the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1523.6.5.2.13 Wind Driven Rain TAS 100(A) 1995
1523.6.5.2.13.1 Physical Properties TAS 110 2Q00
2612.2 Weatherometer ASTM G155 2005
3. REFERENCES:
Entity Examination Reference Date
ATI (TST 1558) Physical Properties 01-49035.01 03/02/2004
ATI (TST 1558) Wind Driven Rain 01-44964.01 01/15/2004
ATI (TST 1558) Wind Driven Rain 60172.01-122-18 10/07/2005
ATI (TST 1558) Physical Properties 59665.02-106-31 09/16/2005
ATI (TST 1558) Wind Driven Rain 84608;01-106-18 11/12/2008
ATI (TST 1558) Wind Driven Rain A5250.01-109-18 02/18/2011
PRI (TST 5878) Weatherometer HBP-007-02-01 06/24/2004
PRI (TST 5878) Physical Properties HBP-002-02-01 06/06/2001
PRI (TST 5878) Wind Driven Rain HBP-01-02-01 11/02/2000
PRI (TST 5878) Wind Driven Rain BRY-021-02-01 12/31/2003
PRI (TST 5878) Physical Properties BRY-025-02-01 09/17/2004
PRI (TST 5878) Physical Properties GAF-138-02-06 02/09/2007 '
PRI (TST 5878) Wind Driven Rain GAF-138-02-04 02/09/2007
PRI (TST 5878) Wind Driven Rain GAF-310-02-01 07/07/2011
ETC Labs (TST 2411) Physical Properties ETC-01-718-10379.0 01/16/2000
ETC Labs (TST 2411) Physical Properties ETC-03-718-14602.0 01/20/2004
ETC Labs (TST 2411) Physical Properties ETC-07-718-19959.0 09/27/2007
Miami-Dade (CER 1592) Various Various NOAs Current
UL, LLC. (QUA 9625) Quality Control Inspection Report 05/01/2013
4. PRODUCT DESCRIPTION:
4.1 Cobra@ Exhaust VentTM is a low-profile attic ridge vent of mesh-construction for use in shingle
roof systems. The product measures 10'/2-inch wide supplied in 20 and 50 ft long rolls.
4.2 Cobra® Rigid Vent 311 is a plastic, low-profile attic ridge vent for use in shingle roof systems
with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch
long sections, and is supplied with 3-inch ring shank nails.
4.3 Cobra® Rigid Vent 31" - 9" is a plastic, low-profile attic ridge vent for use in shingle roof
systems with 10-inch width ridge caps. The product measures 11'/2-inch wide supplied in 48-
inch long sections, and is supplied with 3-inch ring shank nails.
4.4 Cobra® Snow CountryTM is a plastic, low-profile attic ridge vent with filter for use in shingle
roof systems. The product measures 13-13/16-inch wide supplied in 48-inch long sections
Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6
Certificate of Authorization#9503 FL6267-R6
Revision 6: 06/19/2013
Page 2 of 8
TWIT Y11ERD
4.5 Cobra® Snow Country Advanced'" is a plastic, low-profile attic ridge vent with filter for use
in shingle roof systems with 12-inch width ridge caps. The product measures 13-13/16-inch
wide supplied in 48-inch long sections, and is supplied with 3-inch ring shank nails.
4.6. Cobra® Snow Country Advanced'" - 9" is a plastic, low-profile attic ridge vent with filter for
use in shingle roof systems with 10-inch width ridge caps. The product measures 11Y2-inch
wide supplied in 48-inch long sections, and is supplied with 3-inch ring shank nails.
4.7 Cobra@ Ridge Runner'" is a polypropylene plastic, low-profile attic ridge vent for use in
shingle roof systems. The product measures 11 Y2-inch wide supplied in 20 ft long rolls.
4.8 TruSlate@ Ridge Vent is a plastic, low-profile attic ridge vent for use in TruSlatee roof
systems. The product measures 11.4-inch wide supplied in 48-inch long sections.
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ
5.2 Minimum slopes are as follows:
Product Minimum Slope
Cobra®Exhaust Vent 2:12
Cobra® Rigid Vent 3TM 3:12
Cobra@ Rigid Vent 3T - 9" 3:12,
Cobra® Snow CountryTM 3:12
Cobra® Snow Country Advanced'"^ 3:12
Cobra@ Snow Country Advanced TM - 9" 3:12
Cobra® Ridge Runner TM 3:12
TruSlate® Ridge Vent 5:12
5.3 The maximum mean roof height for Cobra@ Exhaust Vent, Cobra@ Rigid Vent 3, Cobra@
Rigid Vent 3 - 9",, Cobra® Snow Country, Cobra@ Snow Country Advanced, Cobra@ Snow
Country Advanced - 9", Cobra@ Ridge Runner and TruSlate@ Ridge Vent shall be 33 ft.
5.4 Installation shall result in minimum net free ventilation area requirements set forth in FBC
Sections 1203.2 and 2326.3.2, with not less than 50% of ventilation from soffit or cornice
vents. When more than one level of roof ridge existing over a"single attic space, use ridge
vents only at the high ridge.
6. INSTALLATION:
6.1 GAF Roof Ventilation Products shall be installed in accordance with GAF published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6
Certificate of Authorization#9503 FL6267-R6
Revision 6: 06/19/2013
Page 3 of 8
ERCP
6.2 COBRA® EXHAUST VENT:
6.2.1 Chalk a cut-line 1-inch off each side of the ridge and cut a slot along the apex of the roof
measuring 2-inch (for truss construction) or 3'h-inch (for ridge pole construction). The slot
should terminate 6-inches from each end and 12-inches from hip intersections or chimneys.
Cut only the sheathing; do not cut trusses. Figure A.
6.2.2 Unroll the vent along the entire length of the ridge, covering uncut 6-inch sheathing area on
both ends. Shorter lengths can bejoined by caulking and butting the ends. Figure B.
6.2.3 Apply a bead of polyurethane roof sealant to the underside of the entire perimeter of the vent
and nail with min. 2'h-inch galvanized roofing nails at each corner and 10-inch o.c, Do not.
use excessive roof cement, as it may result in shingle blistering.
6.2.4 Apply a bead of polyurethane roof sealant in the shape of a "C"to the underside of the entire
perimeter of the cap shingles, and install cap shingles directly over the vent using Smart
Nails"' or 13/4-inch coil nails (supplied with the vent). Figure C. Do not use excessive roof.
cement, as it may result in shingle blistering.
f
i
p•,�«K
1
�..--„,,��''”'-•fey ,�'�_X,= `•-�..a2"`'�.� �� �F o � "�-'--. a'�
6.2.5 Cobra® Exhaust Vent (hand nail version) and Cobra@ Exhaust Vent (nail gun version) have a
3/4-inch or 5/8-inch nominal thickness, respectively, to facilitate ventilation. Care shall be
taken not to crush or compact the product during installation. Figure D.
=a' SY
Hand-Nail Version Nail Gun Version
Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6
Certificate ofAuthorization#9503 FL6267-R6
Revision 6: 06/19/2013
Page 4 of 8
TRINERD
6.3 COBRA® RIGID VENT 3TM, RIGID VENT 3 T - 9", SNOW COUNTRYTM. SNOW COUNTRY ADVANCED'"
AND SNOW COUNTRY ADVANCED'" -9":
6.3.1 Mark-off and cut the slot opening as follows, ensuring that the ends of the opening stop at
least 6-inch,from any end walls and at least 12-inch from hip and ridge intersections or
chimneys.
➢ No Ridge Board: Cut a 7/8-inch opening on each side of the ridge (Figure A).
➢ With Ridge Board: Cut a 1-5/8-inch opening on each side of the ridge (Figure B).
13/411
3 1/4"
No Ridge Board
With Ridge Board
--J
6.3.2 Sealant: Apply a bead of silicone caulking or roof cement-to the underside of the outer baffle
along both edges and at exposed ends, ensuring the outside edges where the vent meets the
shingles are sealed with the caulk or flashing cement.
6.3.3 Vent Placement: Starting at one end of the slot, place, center and conform the Cobra®
rigid vent over the slot with the vent firmly against the roof surface, ensuring the vent
extends past the slot opening by at least 6-inch.
6.3.4 Fasteners: For Cobra® Rigid Vent 3T11, Cobra® Rigid Vent 3 T - 9"', Cobra@ Snow Country
AdvancedTM and Cobra® Snow Country Advanced TM - 9"only, use the E-Z NailTM system.
Grasp attached nails by the head and peel back. Rotate,nail to vertical position for easy
removal. For Cobra® Snow CountryTM, use nails at least 13/4-inch or longer. Nails must
always penetrate through plywood decks or at least 3/4-inch into wood planks. NOTE: GAF
recommends 3-inch ring shank nails for increased uplift resistance.
6.3.5 Spacing: Attach the vent section through the pre-molded nailing holes located at 3, 12, 24,
36 and 45-inch from the start of each 48-inch vent piece.
6.3.6 Joints: Apply the subsequent Cobra® rigid vent sections over the length of the ridge using
the overlap/underlap tabs.
6.3.7 Ridge Shingles: Install ridge shingles in accordance with shingle manufacturer's published
installation instructions, using nails detailed in 6.3.4. A nail line is inscribed on top of the
Cobra® rigid vent to serve as a guide.
Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6
Certificate of Authorization#9503 FL6267-R6 -
Revision 6: 06/19/2013
Page 5 of 8
IER.®
6.4 COBRA@ RIDGE RUNNERrm
6.4.1 Cut slot per 6.3.1.
6.4.2 Tear a 1-foot section to be used as a template for laying the vent out (Figure E-G) and center
the template/ locator over the ridge cap shingles at the beginning of the vent slot. Note the
location of the baffle (Figure H). Make sure to do this at both ends of the installation.
\\
6.4.3 Measure the distance from the edge of the roof slot to the exterior baffle (D). Establish a
chalk line along one side of the ridge (Figure-1). Unroll the vent and use the included 1-3/4-
inch pneumatic roofing. nails to attach the first side of the ridge vent with the exterior of the
baffle aligned with the chalk line (Figure J). ,Proceed with using the 1' interval EasyTearTM
system to custom size the vent to the appropriate length. If the EasyTearTM system can not be
utilized, use a utility knife to size the vent. Nail gun targets are embossed on the part as a
guide for property attaching vent to the roof. The vent should be fastened on 6-inch centers
(Figure K).
d� ) 64
CHALK LINE
e�\
Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6
Certificate ofAuthorization#9503 FL6267-R6
Revision 6: 06/19/2013
Page 6 of 8
JT . `ER
6.4.4 NOTE: When fastening the vent and cap shingles, be sure that the included 1 3/4-inch coil
nails completely penetrate plywood or provide at least 3/4-inch penetration into wood planks.
In the case they do not, you must use alternate nails that provide the required penetration.
Proceed with attaching the other side of the.vent. When beginning to nail down the second
side, do NOT begin at the end; begin between the first and second one-foot sections and then
return to fasten the first one-foot section. This will allow for proper fit.
6.4.5 Install ridge shingles in accordance with shingle manufacturer's published installation
instructions, using the nail-lines on top of the ridge vent for proper lapping.
6.5 TRUSLATEO RIDGE VENT:
6.5.1 DO NOT use on hips.
6.5.2 Intall TruSlate® Ridge Vent before installing the field slates.
6.5.3 After determining the total length of TruSlate® Ridge Vent required (for proper ventilation),
determine the necessary slot opening. Mark-off and cut the slot opening, ensuring the ends
of the opening stop at least 6-inch from any end walls and at least 12-inch from hip and ridge
intersections or chimneys.
6.5.3.1 Roofs without a ridge board: Cut a 7/8-inch opening along the ridge on each side (Figure A).
6.5.3.2 Roofs with a ridge board: Cut a 1-5/8-inch opening along the ridge on each side (Figure B).
Fig. A Fig. B
(41 mm)1 jV Jyg(41 mm)
(22 mm)7/8 7W(22 mm) 11/
(az mm)
` With Ridge Board
13/4'(44 mr11)
No.Ridge Board
6.5.4 Install an 18-inch wide section of ASTM D1970 self-adhering leak barrier (holding Florida
Statewide Product Approval or Approved on a Local Basis) from the edge of the ridge slot
extending down towards the roof deck on both side of the slot.
6.5.5 Place the TruSlate® Ridge Vent over the ridge slot, "peaked"and centered over the ridge slot,
and attach using minimum 3-inch long ring-shank nails through the pre-molded nail holes on
the vent, located 3-inch from the ends and 9-inch o.c. Fasteners shall penetrate through
plywood decks or embed minimum 3/4-inch into wood plank decks.
6.5.6 Continue over the length of the ridge, utilizing the male/female connectors to connect units.
Ensure the finished ends include the pre-molded end caps. Cover all exposed nail heads on
the vent with silicone caulk. Intall a bead of exterior grade silicone sealant at the downslope
leading-edges of the ridge vent, at the junction of the leading edge and the leak-barrier
below.
6.5.7 Install the top course of TruSlate® field slates, UnderBlockTM UV & Moisture Barrier and
TruSlate® trim slates in accordance with GAF published installation instructions. Intall
TruSlate® trim slates with 10-inch exposure using minimum 1-5/8-inch long deck screws
through pre-drilled holes, through the ridge vent to engage the wood deck.
Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6
Certificate of Authorization#9503 FL6267-R6
Revision 6: 06/19/2013
Page 7 of 8
TRI I ERD
R.nmt DecKPrn104tL-n
� 1 257 mm
i_7 }
fo TSH
sj }
Weather WataND ar
SteimGuard(+Leak Sniiktr
7. LABEL I NG:
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 9N-3
QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6
Certificate ofAuthorization#9503 FL6267-R6
Revision 6: 06/19/2013