Loading...
HomeMy WebLinkAboutProduct Approval HOME IMPROVEMENT CONTRACT PLEASE READ THIS CONTRACT ROOFING SPECIFICATION SHEET DESCRIPTION OF WORK Customer Name: M/M mark bond Date: 4/14/2015 Branch Name: Miami Job#: 8186534 Sales Consultant: Paul Stahl LINE- Hurricane Mitigation=No, Premium 10 Year,Atlas GlassMaster,Atlas GlassMaster=Silver White Number of Squares(excluding Low Slope):=13.33, Number of Flat Roof Squares=0 Flashing Misc Linear Ft of Drip Edge to be Installed=170, Color of Drip Rigid Ridge Vent=Yes,Linear Ft Ridge Vent to be Edge to be Installed=White Installed=36, Rigid Ridge Vent-Color=Black, Off Ridge Vent=No, Replace Fascia=No, Hurricane Mitigation Inspection=No Pricing Includes: Drip Edge-in 10ft Sgmts Shingle Removal and Application. SPEC>(AL CONSIDERATIONS t ,. PRE EXISTING CONDITIONS 3 r ADDITIONAL CHARGES t If rotted or damaged wood is discovered AFTER removing the existing roofing,or could -fled at the time of sale,there-will be an additional charge of$ 72 per sheet of 4x8 sheathing and/or$ 6 per linear ft.of ensional lumber for decking., N :� If additional layers of roofing are discovered AFTER removing the fust layer,or could not be identified at the time ak s e,(here w#l,,Be an additional charge per square to remove each additional layer based on product to be removed: v.. $ 21 for composition shingles,$ 55 for wood shingles.Low or flat roofs will be priced on a per job basis bast ons complexity. �� CONTRACT"- MOUNT - ; $S,v27 00' F 06/17/14-SA Page 7 of 8 Florida Building Code Online Page 1 of 2 tF Florit Deeparnenttf BCIS Home Log In { User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search Bus ines � � Product ApprovalP' [Q J'd: aI USER:Public User Prodret AM.royal Menu>Product or Aonlicatim Search>Anocation list>Application Detail ...,'.. FL# FL9792-R5 21 != Application Type Revision Code Version 2010 Application Status Approved Comments Archived Product Manufacturer Atlas Roofing Corporation Address/Phone/Email 2000 RiverEdge Parkway Suite 800 Atlanta, GA 30328 (770) 933-4477 etodd@atlasroofi ng.com Authorized Signature Ed Todd etoddCa)atlasroofl ng.com Technical Representative Ed Todd Address/Phone/Email 2000 Riveredge Pkwy Suite 800 Atlanta, GA 30328 (770) 933-4477 etodd@atlasroofi ng.com Quality Assurance Representative Address/Phone/Email Category (Asphalt ofing Subcategory Shingles Compliance Method Evaluation Report from a Florida Register hit t or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received l*40 Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity LIL LLC Quality Assurance Contract Expiration Date 09/10/2013 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy Received 0 Certificate of Independence FL9792 R5 COI Trinity ERD CI -Niemilien.Ddf Referenced Standard and Year(of Standard) Standard ASTM D3161, Class F ASTM D3462 0 0 ASTM D7158, Class H TAS 100yj1 TAS 107 1 m Equivalence of Product Standards Certified By http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs2cHSPuWTxiRW... 6/12/2013 Florida Building Code Online Page 2 of 2 f Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/16/2012 Date Validated 10/19/2012 Date Pending FBC Approval 10/31/2012 Date Approved 12/04/2012 � v of Products FL# Model,Number or Name IDescription 9792.1 Atlas Asphalt Roof Shin les Fiberglass reinforced asphalt roof shingles Limas of Use Installation Instructions Approved for use in HVHZ:Yes FI-9792 R5 11 er101520121FINAL ATLAS FI-9792- Approved for use outside HVHZ:Yes. R5 Asphalt Shingles.odf ( Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use and ER Evaluation Reports Section 6 for Installation Requirements. FL9792 R5 AE er10152012FINAL ATLAS FL9792- R5 Asp alt Shin lace sTndf Created by Independent Third Party. Yes Back Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone,850-487-1824 The State of Florida is an AA/EEO employer.Convriaht 2007-2010 State of Florida.::Privaev Statement::Accessibility tat.m n ::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click bgrg. Product Approval Accepts: - - . SCCLtT'itt•.3i'.i>C7k.[t'S" http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgs2cHSPuVVTxiRW... 6/12/2013 EXTERIOR. RESEARCH & DESIGN, LLC. Certificate of Authorization#9503 '�QTRINI-ff 353 CHRISTIAN STREET, UNIT #13 ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX:_(203) 262-9243 EVALUATION REPORT Atlas Roofing Corporation Evaluation Report Al 2620.12.08-114 2,060 River Edge Parkway FL9792-115 Atlanta, GA 30328 Date of Issuance: 12/18/2008 Revision 4: 10/15/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: Atlas Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. For HVHZ, shingles shall be labeled in accordance with Miami- Dade requirements. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity ERD requires a complete review of this Evaluation- Report valuation-Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by _ the manufacturer or its distributors and- shall be available for inspection at' the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: - ' The facsimile seal appearing was authorized :-:�; ..�4sa,��4',.? by Robert Nieminen,P.E.on 10/15/2012 This does not serve as an electronically signed �. document. Signed,sealed Robert J.M. Nieminen, P.E. ;w�Ar ,"J ,�` transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DCA ANE1983 to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company.manufacturing or distributing products it evaluates. ' 2. TrinitylERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. I TRTY ER,D. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Atlas Asphalt Roof Shingles, as produced Atlas Roofing Corporation, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2,6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2007 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 1523.6.5.1 Wind Driven Rain TAS 100 1995 3. REFERENCES: Entity Examination Reference Date. ATI (TST 1558) Wind Driven Rain TAS 100 01/30/1998 PRI (TST 5878) Wind Driven Rain TAS 100 07/09/2003 PRI (TST 5878) Physical Properties ATL-021-02-01 04/08/2005 PRI (TST 5878) Wind Driven Rain TAS 100 01/31 /2005 PRI (TST 5878) Wind Driven Rain ATL-020-02-01 02/03/2005 PRI (TST 5878) Physical Properties ASTM D3462 05/02/2005 PRI (TST 5878) Physical Properties. ATL-035-02-01 10/12/2007 PRI (TST 5878) Wind Driven Rain ATL-036-02-01, 02/28/2008 PRI (TST 5878) Wind Resistance ATL-054-02-01 04/29/2010 PRI (TST 5878) Wind Driven Rain ATL-053-02-01 05/03/2010 . PRI (TST 5878) Physical Properties ATL-055-02-01 05/12/2010 PRI (TST 5878) Wind Resistance ATL-054-02-01 04/29/2010 PRI (TST 5878) Wind Resistance , ATL-056-02-01 06/21/2010 PRI (TST 5878). Wind Driven Rain ATL-020-02-01; Addendum 09/09/2011 PRI (TST 5878) Physical Properties ATL-021-02-01; Addendum 09/09%2011 PRI (TST 5878) Wind Resistance ATL-079-02-01 02/17/2012 PRI (TST 5878) Wind Driven Rain ATL-081-02-01 02/17/2012 PRI (TST 5878) Wind Resistance ATL-081-02-02 02/17/2012 UL (TST 1740) -Wind Resistance TAS 107 06/09/1999 UL (TST 1740) Wind Resistance 02NK6989 03/04/2002 UL (TST 1740) Wind Resistance 05CA03322 05/06/2005 UL (TST 1740) Wind Resistance TAS 107 09/15/2005 UL (TST 1740) Wind Resistance TAS 107 /.02NK6989 03/04/2002 UL (TST 1740) Physical Properties ASTM D3462/R4052 09/17/2002 UL (TST 1740) Physical Properties ASTM D3462/R4052 03/02/2006 UL (TST 1740) Wind Resistance 07CA26303 08/31/2007 UL (TST 1740) Physical Properties ASTM D3462/ R4052 11/14/2007 UL (TST 1740) Wind Classification 07NK22068 04/29/2008 Miami-Dade (CER 1592) HVHZ Compliance 07-0927.06 04/10/2008 Miami-Dade (CER 1592) HVHZ Compliance 09-0114.01 03/11/2009 Miami-Dade (CER 1592) HVHZ Compliance 10-0519.03 08/04/2010 Miami-Dade (CER 1592) HVHZ Compliance 10-0519.04 08/04/2010 Atlas Roofing Trade Name Documentation Trade Name Documentation 02/03/2012 Atlas Roofing Trade Name Documentation Trade Name Documentation 02/07/2012 Atlas Roofing Trade Name Documentation Trade Name Documentation '02/23/2012 UL LLC(QUA 9625) Quality Control Inspection Report; R4052 01/18/2012 UL LLC(QUA 9625) Quality Control Inspection Report; R4052 09/10/2012 Exterior Research and Design, LLC. Evaluation Report All 2620.12.08-R4 Certificate of Authorization#9503 FL9792-R5 Revision 4: 10/15/2012 Page 2 of 5 -liTRINITYI ERD 4. PRODUCT DESCRIPTION: 4.1 GlassMaster® 25, GlassMaster® 30, Tough-Glass 20 and StormMaster® Slate are fiberglass reinforced, 3-tab asphalt roof shingles. 4.2 Pinnacle®, Pinnacle® 35, Pinnacle® Lifetime, Pinnacle® Lifetime with ScotchgardT'", Pinnacle® HP, and StormMaster® Shake with Scotchgard7m (formerly StormMaster® LM) are fiberglass reinforced, laminated asphalt roof shingles. 5. LIMITATIONS: 5.1 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.2 Wind Classification (non-HVHZ): 5.2.1 GlassMaster® 25, GlassMaster® 30, Tough-Glass 20, StormMaster® Slate, Pinnacle® HP and StormMaster® Shake with ScotchgarclTM (formerly-StormMaster® LM) shingles noted herein have been tested in accordance with FBC Table 1507.2.7.1 and R905.2.6.1 to UL3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasa = 150 mph (Vint = 194 mph). Refer to Section 6.1 for installation requirements to meet this wind rating. 5.2.2 GlassMaster® 25, GlassMaster® 30, Tough-Glass 20, StormMaster® Slate, Pinnacle®, Pinnacle® 35, Pinnacle® Lifetime,'Pinnaclee Lifetime with Scotchgard TM, StormMaster® Shake with ScotchgardTM (formerly StormMaster® LM) have been tested / examined in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V"it = 194 mph). Refer to Section 6.1 for installation requirements to meet this wind rating. 5.2.2.1 Classification by ASTM D7158 applies to exposure category B or C and a building height of . 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data.specific to each shingle. 5.3 Wind Resistance (HVHZ): 5.3.1 GlassMaster® 25, GlassMaster® 30, Tough-Glass 20, StormMaster® Slate, Pinnacle®, Pinnacle® 35, Pinnacle® Lifetime, Pinnacle® Lifetime with ScotchgardTM, Pinnacle® HP and StormMaster® Shake with ScotchgardT'" (formerly StormMaster LM) have been tested / examined in accordance with TAS 107 and TAS 100, and are suitable for use in HVHZ. Refer to.Section 6.2 for installation requirements for HVHZ. 5.3.2 Shall not be installed on roof mean heights in excess of 33 feet. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Non-HVHZ: 6.1.1 Underlayment: 6.1.1.1 Underlayment shall be acceptable to Atlas Roofing Corporation and shall hold current Florida Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.2 Asphalt Shingles: Exterior Research and Design, LLC. Evaluation Report Al 2620.12.08-R4 Certificate of Authorization#9503 FL9792-R5 Revision 4: 10/15/2012 Page 3 of 5 TRINITY ERD. 6.1.2.1 Installation of asphalt shingles shall comply with the manufacturer's . current published instructions, using minimum four (4) nails per shingle in accordance with the requirements of FBC Sections 1507.2 or R905:2. 6.1.2.2 Nails and nail placement shall be in accordance with manufacturer's current published installation instructions, but not less than. FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.2.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact Atlas Roofing for details. 6.2 HVHZ: 6.2.1 Shingles and flashings shall be installed in accordance with RAS 115. 6.2.2 The manufacturer shall provide clearly written -application instructions to be used in conjunction with RAS 115. Should a particular section of the. installation instructions conflict with RAS 115, the requirements of RAS 115 prevail. 6.2.3 Nail placement requirements are as detailed below. 6.2.3.1 GlassMaster® 25, GlassMaster® 30, Tough-Glass 20: Balls � 1{p 12" 12 6.2.3.2 Storm Master® Slate: 19 Z' 8-z" 1" 7_s., 16 2 8 I 22-IJ" Exterior Research and Design, LLC. Evaluation Report Al 2620.12.08-R4 Certificate of Authorization#9503 FL9792-R5 Revision 4: 10/15/2012 Page 4 of 5 TRINITYER.D. 6.2.3.3 Pinnacle®, Pinnacle° 35, Pinnacle° Lifetime, Pinnacle Lifetime® with Scotchgard TM, StormMaster® Shake with Scotchgard"I (formerly StormMaster LM): 6.2.3.4 Pinnacle® HP: Nailthraughthetf dou6lelayerarea I i Irr Exposure, I I ,` i :.Exposiciori 17 ,. 75/87—1 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. For HVHZ, shingles shall be labeled in accordance with HVHZ requirements. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507:2.7.1 /•R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted'QA agency for information on product locations covered by QA procedures 10. QUALITY ASSURANCE ENTITY: UL LLC - QUA9625 (T) 847-664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report Al 2620.12.08-R4 Certificate ofAuthorization#9503 - FL9792-R5 Revision 4: 10/15/2012 Page 5 of 5 Florida Building Code Online Page 1 of 2 7777777777-717 tit t BCIS Home 1 Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map4 Links 1 Search Busines��,� : ser Profess nab jr(j-'. Pro. uctuApp�oval Regulation } I.-. Product Approval Menu>Product or Application Search>Application List>Application Detail FL# - FL6267-R6 Application Type Revision Code Version 2010 . Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1361 Alps Road Wayne,NJ 07470 (973)872-4421 lindareith@trinityerd.com Authorized Signature Beth McSorley lindareith@trinityerd.com Technical Representative Beth McSorley Address/Phone/Email 1361 Alps Road-Bldg 11-1 Wayne,NJ 07470 (973)872-4421 BMcSorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer s] Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who Robert Nieminen developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/01/2014 Validated By John W. Knezevich,PE ._ Validation Checklist Hardcopy Received Certificate of Independence FL6267 R6 COI Trinity ERD CI-Nieminen-2013.pdf Referenced Standard and Year(of Standard) Standard Year ASTM G155 2005 TAS 100(A) 1995 TAS 110 2000 Equivalence of Product Standards Certified By http://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqu02YBW7bM8MZA... 8/23/2013 Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/21/2013 Date Validated 06/24/2013 Date Pending FBC Approval 07/01/2013 Date Approved 08/23/2013 ----- ....._._...._.__. ..................... -.---............................ ---.._.._......._......-----.............. -- Summary of Products --IlModel,Number or Name Description 6267.1 GAF Roof Ventilation Products Low profile roof ridge vents Limits of Use Installation Instructions Approved for use in HVHZ:No FL6267 R6 II er061913FINAL GAF Ventilation FL6267- Approved for use outside HVHZ:Yes R6.Ddf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER Section 5 for Limits of Use. Evaluation Reports FL6267 R6 AE er061913FINAL GAF Ventilation FL6267 - R6 Created by Independent Third Party:Yes . Back Next ' Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2010 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not ' send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. - *Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public. _ To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ECGeck .-_ security ntt'rstics' . http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu02YBW7bM8MZA... 8/23/2013 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization#9503 353 CHRISTIAN STREET, UNIT #13 ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT GAF Evaluation Report 01506.02.06-R6 1361 Alps Road, Building 7-3 FL6267-116 Wayne, NJ 07470 Date of Issuance: 02/28/2006 Revision 6: 06/19/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections referenced herein. DESCRIPTION: GAF Roof Ventilation Products LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes; or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. - ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared.by: p' •• '` The facsimile seal appearing was authorized by Robert Nieminen,P.E.on 06/19/2013 �..F•y-^•,; r This does.not serve as an electronically signed Robert J.M. Nieminen P.E. °�;Fs;: document. Signed,sealed hardcopies have been x iO 4�.`•'" transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DCA ANE1983 to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinitylERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. r QTRINERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: GAF Roof Ventilation Products, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1523.6.5.2.13 Wind Driven Rain TAS 100(A) 1995 1523.6.5.2.13.1 Physical Properties TAS 110 2Q00 2612.2 Weatherometer ASTM G155 2005 3. REFERENCES: Entity Examination Reference Date ATI (TST 1558) Physical Properties 01-49035.01 03/02/2004 ATI (TST 1558) Wind Driven Rain 01-44964.01 01/15/2004 ATI (TST 1558) Wind Driven Rain 60172.01-122-18 10/07/2005 ATI (TST 1558) Physical Properties 59665.02-106-31 09/16/2005 ATI (TST 1558) Wind Driven Rain 84608;01-106-18 11/12/2008 ATI (TST 1558) Wind Driven Rain A5250.01-109-18 02/18/2011 PRI (TST 5878) Weatherometer HBP-007-02-01 06/24/2004 PRI (TST 5878) Physical Properties HBP-002-02-01 06/06/2001 PRI (TST 5878) Wind Driven Rain HBP-01-02-01 11/02/2000 PRI (TST 5878) Wind Driven Rain BRY-021-02-01 12/31/2003 PRI (TST 5878) Physical Properties BRY-025-02-01 09/17/2004 PRI (TST 5878) Physical Properties GAF-138-02-06 02/09/2007 ' PRI (TST 5878) Wind Driven Rain GAF-138-02-04 02/09/2007 PRI (TST 5878) Wind Driven Rain GAF-310-02-01 07/07/2011 ETC Labs (TST 2411) Physical Properties ETC-01-718-10379.0 01/16/2000 ETC Labs (TST 2411) Physical Properties ETC-03-718-14602.0 01/20/2004 ETC Labs (TST 2411) Physical Properties ETC-07-718-19959.0 09/27/2007 Miami-Dade (CER 1592) Various Various NOAs Current UL, LLC. (QUA 9625) Quality Control Inspection Report 05/01/2013 4. PRODUCT DESCRIPTION: 4.1 Cobra@ Exhaust VentTM is a low-profile attic ridge vent of mesh-construction for use in shingle roof systems. The product measures 10'/2-inch wide supplied in 20 and 50 ft long rolls. 4.2 Cobra® Rigid Vent 311 is a plastic, low-profile attic ridge vent for use in shingle roof systems with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and is supplied with 3-inch ring shank nails. 4.3 Cobra® Rigid Vent 31" - 9" is a plastic, low-profile attic ridge vent for use in shingle roof systems with 10-inch width ridge caps. The product measures 11'/2-inch wide supplied in 48- inch long sections, and is supplied with 3-inch ring shank nails. 4.4 Cobra® Snow CountryTM is a plastic, low-profile attic ridge vent with filter for use in shingle roof systems. The product measures 13-13/16-inch wide supplied in 48-inch long sections Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate of Authorization#9503 FL6267-R6 Revision 6: 06/19/2013 Page 2 of 8 TWIT Y11ERD 4.5 Cobra® Snow Country Advanced'" is a plastic, low-profile attic ridge vent with filter for use in shingle roof systems with 12-inch width ridge caps. The product measures 13-13/16-inch wide supplied in 48-inch long sections, and is supplied with 3-inch ring shank nails. 4.6. Cobra® Snow Country Advanced'" - 9" is a plastic, low-profile attic ridge vent with filter for use in shingle roof systems with 10-inch width ridge caps. The product measures 11Y2-inch wide supplied in 48-inch long sections, and is supplied with 3-inch ring shank nails. 4.7 Cobra@ Ridge Runner'" is a polypropylene plastic, low-profile attic ridge vent for use in shingle roof systems. The product measures 11 Y2-inch wide supplied in 20 ft long rolls. 4.8 TruSlate@ Ridge Vent is a plastic, low-profile attic ridge vent for use in TruSlatee roof systems. The product measures 11.4-inch wide supplied in 48-inch long sections. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ 5.2 Minimum slopes are as follows: Product Minimum Slope Cobra®Exhaust Vent 2:12 Cobra® Rigid Vent 3TM 3:12 Cobra@ Rigid Vent 3T - 9" 3:12, Cobra® Snow CountryTM 3:12 Cobra® Snow Country Advanced'"^ 3:12 Cobra@ Snow Country Advanced TM - 9" 3:12 Cobra® Ridge Runner TM 3:12 TruSlate® Ridge Vent 5:12 5.3 The maximum mean roof height for Cobra@ Exhaust Vent, Cobra@ Rigid Vent 3, Cobra@ Rigid Vent 3 - 9",, Cobra® Snow Country, Cobra@ Snow Country Advanced, Cobra@ Snow Country Advanced - 9", Cobra@ Ridge Runner and TruSlate@ Ridge Vent shall be 33 ft. 5.4 Installation shall result in minimum net free ventilation area requirements set forth in FBC Sections 1203.2 and 2326.3.2, with not less than 50% of ventilation from soffit or cornice vents. When more than one level of roof ridge existing over a"single attic space, use ridge vents only at the high ridge. 6. INSTALLATION: 6.1 GAF Roof Ventilation Products shall be installed in accordance with GAF published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate of Authorization#9503 FL6267-R6 Revision 6: 06/19/2013 Page 3 of 8 ERCP 6.2 COBRA® EXHAUST VENT: 6.2.1 Chalk a cut-line 1-inch off each side of the ridge and cut a slot along the apex of the roof measuring 2-inch (for truss construction) or 3'h-inch (for ridge pole construction). The slot should terminate 6-inches from each end and 12-inches from hip intersections or chimneys. Cut only the sheathing; do not cut trusses. Figure A. 6.2.2 Unroll the vent along the entire length of the ridge, covering uncut 6-inch sheathing area on both ends. Shorter lengths can bejoined by caulking and butting the ends. Figure B. 6.2.3 Apply a bead of polyurethane roof sealant to the underside of the entire perimeter of the vent and nail with min. 2'h-inch galvanized roofing nails at each corner and 10-inch o.c, Do not. use excessive roof cement, as it may result in shingle blistering. 6.2.4 Apply a bead of polyurethane roof sealant in the shape of a "C"to the underside of the entire perimeter of the cap shingles, and install cap shingles directly over the vent using Smart Nails"' or 13/4-inch coil nails (supplied with the vent). Figure C. Do not use excessive roof. cement, as it may result in shingle blistering. f i p•,�«K 1 �..--„,,��''”'-•fey ,�'�_X,= `•-�..a2"`'�.� �� �F o � "�-'--. a'� 6.2.5 Cobra® Exhaust Vent (hand nail version) and Cobra@ Exhaust Vent (nail gun version) have a 3/4-inch or 5/8-inch nominal thickness, respectively, to facilitate ventilation. Care shall be taken not to crush or compact the product during installation. Figure D. =a' SY Hand-Nail Version Nail Gun Version Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate ofAuthorization#9503 FL6267-R6 Revision 6: 06/19/2013 Page 4 of 8 TRINERD 6.3 COBRA® RIGID VENT 3TM, RIGID VENT 3 T - 9", SNOW COUNTRYTM. SNOW COUNTRY ADVANCED'" AND SNOW COUNTRY ADVANCED'" -9": 6.3.1 Mark-off and cut the slot opening as follows, ensuring that the ends of the opening stop at least 6-inch,from any end walls and at least 12-inch from hip and ridge intersections or chimneys. ➢ No Ridge Board: Cut a 7/8-inch opening on each side of the ridge (Figure A). ➢ With Ridge Board: Cut a 1-5/8-inch opening on each side of the ridge (Figure B). 13/411 3 1/4" No Ridge Board With Ridge Board --J 6.3.2 Sealant: Apply a bead of silicone caulking or roof cement-to the underside of the outer baffle along both edges and at exposed ends, ensuring the outside edges where the vent meets the shingles are sealed with the caulk or flashing cement. 6.3.3 Vent Placement: Starting at one end of the slot, place, center and conform the Cobra® rigid vent over the slot with the vent firmly against the roof surface, ensuring the vent extends past the slot opening by at least 6-inch. 6.3.4 Fasteners: For Cobra® Rigid Vent 3T11, Cobra® Rigid Vent 3 T - 9"', Cobra@ Snow Country AdvancedTM and Cobra® Snow Country Advanced TM - 9"only, use the E-Z NailTM system. Grasp attached nails by the head and peel back. Rotate,nail to vertical position for easy removal. For Cobra® Snow CountryTM, use nails at least 13/4-inch or longer. Nails must always penetrate through plywood decks or at least 3/4-inch into wood planks. NOTE: GAF recommends 3-inch ring shank nails for increased uplift resistance. 6.3.5 Spacing: Attach the vent section through the pre-molded nailing holes located at 3, 12, 24, 36 and 45-inch from the start of each 48-inch vent piece. 6.3.6 Joints: Apply the subsequent Cobra® rigid vent sections over the length of the ridge using the overlap/underlap tabs. 6.3.7 Ridge Shingles: Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using nails detailed in 6.3.4. A nail line is inscribed on top of the Cobra® rigid vent to serve as a guide. Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate of Authorization#9503 FL6267-R6 - Revision 6: 06/19/2013 Page 5 of 8 IER.® 6.4 COBRA@ RIDGE RUNNERrm 6.4.1 Cut slot per 6.3.1. 6.4.2 Tear a 1-foot section to be used as a template for laying the vent out (Figure E-G) and center the template/ locator over the ridge cap shingles at the beginning of the vent slot. Note the location of the baffle (Figure H). Make sure to do this at both ends of the installation. \\ 6.4.3 Measure the distance from the edge of the roof slot to the exterior baffle (D). Establish a chalk line along one side of the ridge (Figure-1). Unroll the vent and use the included 1-3/4- inch pneumatic roofing. nails to attach the first side of the ridge vent with the exterior of the baffle aligned with the chalk line (Figure J). ,Proceed with using the 1' interval EasyTearTM system to custom size the vent to the appropriate length. If the EasyTearTM system can not be utilized, use a utility knife to size the vent. Nail gun targets are embossed on the part as a guide for property attaching vent to the roof. The vent should be fastened on 6-inch centers (Figure K). d� ) 64 CHALK LINE e�\ Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate ofAuthorization#9503 FL6267-R6 Revision 6: 06/19/2013 Page 6 of 8 JT . `ER 6.4.4 NOTE: When fastening the vent and cap shingles, be sure that the included 1 3/4-inch coil nails completely penetrate plywood or provide at least 3/4-inch penetration into wood planks. In the case they do not, you must use alternate nails that provide the required penetration. Proceed with attaching the other side of the.vent. When beginning to nail down the second side, do NOT begin at the end; begin between the first and second one-foot sections and then return to fasten the first one-foot section. This will allow for proper fit. 6.4.5 Install ridge shingles in accordance with shingle manufacturer's published installation instructions, using the nail-lines on top of the ridge vent for proper lapping. 6.5 TRUSLATEO RIDGE VENT: 6.5.1 DO NOT use on hips. 6.5.2 Intall TruSlate® Ridge Vent before installing the field slates. 6.5.3 After determining the total length of TruSlate® Ridge Vent required (for proper ventilation), determine the necessary slot opening. Mark-off and cut the slot opening, ensuring the ends of the opening stop at least 6-inch from any end walls and at least 12-inch from hip and ridge intersections or chimneys. 6.5.3.1 Roofs without a ridge board: Cut a 7/8-inch opening along the ridge on each side (Figure A). 6.5.3.2 Roofs with a ridge board: Cut a 1-5/8-inch opening along the ridge on each side (Figure B). Fig. A Fig. B (41 mm)1 jV Jyg(41 mm) (22 mm)7/8 7W(22 mm) 11/ (az mm) ` With Ridge Board 13/4'(44 mr11) No.Ridge Board 6.5.4 Install an 18-inch wide section of ASTM D1970 self-adhering leak barrier (holding Florida Statewide Product Approval or Approved on a Local Basis) from the edge of the ridge slot extending down towards the roof deck on both side of the slot. 6.5.5 Place the TruSlate® Ridge Vent over the ridge slot, "peaked"and centered over the ridge slot, and attach using minimum 3-inch long ring-shank nails through the pre-molded nail holes on the vent, located 3-inch from the ends and 9-inch o.c. Fasteners shall penetrate through plywood decks or embed minimum 3/4-inch into wood plank decks. 6.5.6 Continue over the length of the ridge, utilizing the male/female connectors to connect units. Ensure the finished ends include the pre-molded end caps. Cover all exposed nail heads on the vent with silicone caulk. Intall a bead of exterior grade silicone sealant at the downslope leading-edges of the ridge vent, at the junction of the leading edge and the leak-barrier below. 6.5.7 Install the top course of TruSlate® field slates, UnderBlockTM UV & Moisture Barrier and TruSlate® trim slates in accordance with GAF published installation instructions. Intall TruSlate® trim slates with 10-inch exposure using minimum 1-5/8-inch long deck screws through pre-drilled holes, through the ridge vent to engage the wood deck. Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate of Authorization#9503 FL6267-R6 Revision 6: 06/19/2013 Page 7 of 8 TRI I ERD R.nmt DecKPrn104tL-n � 1 257 mm i_7 } fo TSH sj } Weather WataND ar SteimGuard(+Leak Sniiktr 7. LABEL I NG: Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 01506.02.06-R6 Certificate ofAuthorization#9503 FL6267-R6 Revision 6: 06/19/2013 Page 8 of 8