Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online http://www.Iloridabuilding.orgJpr/pr_app_dtl.aspx?param=wGEVXQ... sr� FWda Npallme ltd EMS Home Login user Registration Hot Topics , Submit Surcharge Stats.&Facts Publications FBC Staff i SCIS Site Map j Links Search Busines `��}` E Product Approval Professil 11 USER:Public user Regulation Product Approval Menu>Producs oEAPPIlcationSgarch>Aporcatlon List>Applleation DetaO FL# FL1956=R8`� Application Type Revision Code Version 2b;10 + Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived Product Manufacturer T\AMKO Buildingpcoducts;;Inc: Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Authorized Signature Kerri Eden kerri_eden@tamko.com Technical Representative Kerr' den �/®� Address/Phone/Email P 404. (41 _64842 Ext 2305 ke tamko.com Quality Assurance Representative. . y Address/Phone/Emal l Category Roofing Subcategory Asphalt Shingles r . Compliance Method Certification Mark or Listin Certification Agency UL LLC Validated By Robert]. M. Nleminen,PE Validation Checklist-Hardcopy Rec Ived Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2006 ASTM D3462 2007 ASTM D7158 2007 Equivalence of Product Standards Certified By Product Approval Method Method i Option A 1 of 4 11/7/2013 8:49 AM Florida Building Code Online http://www.floridabuilding.org(pr/pr_app_dtl.aspx?param--wGEVXQ... Date Submitted 09/27/2012 Date Validated 10/15/2012 Date Pending FBC Approval Date Approved 10/16/2012 Summary of Products FL# Model,Number or Name Description 1956.1 Elite Glass-SealA three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No F_L1956 R8_C_CAC_Tamko Sery Conf FL 1956 2012.ndf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certiFlcatlon 10-11-12.pdf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or.greater.Nails must be used FL1956 R8 II plass seal elite app Inst april 10.pdf as the method of attachment. FL1956 R8 II glass seal elite apo inst f april 10.pdf FL1956 R8 II TAMKO Glass-Seal Elite Glass-Seal (Frederick Joplin Tuscaloosa).Pdf Verified By: Robert Nieminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.2 Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 'R8 C CAC Tamko Sery Conf FL 1956 2012.odf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10-11-12.odf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/16/2015 Other:Asphalt shingles shall be used only on. Installation Instructions roof slopes of 2:12 or greater. Nails must be used FL1956 R8 II glass seal elite app inst april 10,pdf as the method of attachment. FL1956 R8 II TAMKO Glass-Seal Elite Glass-Seal(Frederick Joolin Tuscaloosa).pdf Verified By: Robert Nieminen PE 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.3 Heritage A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10-11-12.odf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure:N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12.or greater.Nails must be used FL1956 R8 II heritage app Inst-sept 12.pdf as the method of attachment. FL1956 R8 II heritage app inst frederick.pdf Verified By: Robert J.M. Nieminen FL 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956,.,4w:- Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC OL certification 10-11-12.odf Impact Resistant:,N/A Quality Assurance Contract Expiration Date Design Pressure:N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or greater.Nails must be used FL1956 R8 II heritage 30 aop Inst aural 10.odf as the method of attachment. FL1956 R8 II heritage 30 app Inst f april Modf Verified By: Robert Nieminen PE 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.5 Heritage 50 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10-11-12.odf 2 of 11/7/2013 8:49 AM Florida Building Code Online http://www.floridabuilding.ore/ r/pr_app_dtl.aspx?paraM7W VXQ... Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or.greater.Nails must be used FL1956 R8 II heritage 50 app Inst april 10.pdf as the method of attachment. FL1956 R8 II.heritage 50 aoo Inst f aprll 10.1)df Verified By: Robert Nleminen PE 59166 Created by Independent Third Party: No . Evaluation Reports Created by Independent Third Party: 1956.6 Heritage PremiumA dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certiflcatlon 10-11-12.pdf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or greater.Nails must be used. FL1956 R8 II heritage prem app inst.pdf as the method of attachment. FL1956 R8 II heritage prem app Inst frederick.pdf Verified By: Robert Nleminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.7 Heritage Woodgate A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certiflcatlon 10-11-12.pdf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or greater.Nalls.must be used FL1956 R8 II Woodgate app inst D Oct 11.1)df as the method of attachment. FL1956 R8 H Woodoate app Inst F Oct 11.Ddf Verified By: Robert Nieminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.8 Heritage XL A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certiflcatlon 10-11-12.odf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure:N/A 10/10/2035 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or greater. Nails must be used FL1956 R8 II heritage A app Inst d april Modf as the method of attachment. FL1956 R8 II heritage A app Inst f april 10.pdf. Verified By: Robert Nieminen PE 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.9 Hip and Ridge Shingles Hip and ridge shingles Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL1956 RB C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 RB C CAC UL certification 10-11-12.Ddf Impact.Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Hip and Ridge shingles shall be used only Installation Instructions on roof slopes of 2:12 or greater. Nails must be FL1956 R8 II 12 25 x 12 Hio Ridge Apolicatlon Instructlons.odf used as the method of attachment. FL1956 R8 II 12 x 12 Hip Ridge ADolicatlon Instructions.pdf FL1956 R8 II 12-1-4x12 HiDRidge Sealant Dab Illustrations.pdf FL1956 RS II 12x12 HipRidoe Sealant Dab Illustrations.Ddf Verified By: Robert Nleminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: Back .Naxt 3'of 4 11/7/2013'8:49 AM U October 11, 2012 Tamko Building Products Inc Ms.Kerri Eden 220 W 4th St PO Box 1404 Joplin,MO 64801 RE: TAMKO Shingles Dear Ms.Eden: This is to confirm that the attached shingle matrix pertains to Tamko produced shingles. All the products have been tested and meet the criteria for the standards mentioned. They are covered by UL's Follow-Up Service Program under Tamko's File R2919. The Listing Mark of Underwriters Laboratories Inc. on the product is the only method provided by UL to identify products manufactured under its Listing and Follow-Up Service. Combination Listing/Classification Mark—A Listing Mark combined with a Classification Mark is provided on products that have additionally been investigated in accordance with various supplemental standards. Please refer to the labels on the product. Should you have any questions,please feel free to contact the writer. Very truly yours, Reviewed By: William G Marshall (Ext. 42735) Alpesh Patel (Ext.42522) Sr. Engineering Associate Staff Engineer Fire Protection Division 3019A Fire Protection Division 3019A U� TWO Shingle Matrix Phillipsburg, KS Frederick, 0 Product Nasi ASTM ASTM ASTM UL ASTMS CSA PrOdUCt Naas ASM ASTM ASTH IIS. ASTM CSA D2462 D2161 D6281 2390 D715B 123.5 D3462 D2161 D6281 2390 D7158 123.5 Class Mass: Mass Mass Class Class Mass Mass. F H H H H H H Glass-Seal (AR) Glass-Beal (AR} x x x x x Elite Glass-Seal (AR} Elise Glass-Seal (AR} x x x x x Heritage x x x x x x Heritage x x x x x x Heritage 30 (AR} x x x x x x Heritage 30 (AR) x x x x x x Heritage XL (AR) Heritage XL (AR} x x - - Heritage w0cmigate X X - - - Heritage 50 (AR} x x x x x x Heritage 50 (AR} x x x x x x Heritage Premium x x x x x x Heritage :yuan x x x x x x Heritage Vintage (AR} x x x x x x Heritage Vintage (AR) Heritage vintage X A ---- ---- ---- 12-1/4 x 12 Hip and Ridge x x ---- ---- ---- 12 X 12 Hip and Ridge Dallas, Tx TusealuGsa, Al Product Nam ASTM ASTM ASTM UL ASTM CSA UL Product Name ASTL ASTM ASTM DL ASTMU CSA D2462 D2161 D6281 2290 D7158 123.5 2218 D2462 D2161 D6281 2390 D7158 123.5 Class Class Class Mass Class Mass Class Class F H H H F H H H Glass-Seal (AR) Mass-Seal (AR} x x x x x Elite Glawrkal (AR} Elite Mass-Seal (AR} x x x x x Heritage x x x x x x Heritage x x x x x x Heritage 30 (AR} x x x x x x Heritage 30 (AR) x x x x x x Heritage XL (AR} x x x x x Heritage XL (AR} Heritage xoodgate x x x x x x Heritage 50 (AR) x x x x x x Heritage 50 (AR} x x x x x x Heritage Pxemium x x x x x x Heritage Premium x x x x x x Heritage Vintage (AR) Heritage Vintage (AR} Heritage 3:R X X X X X X X 12 x 12 Hip and Ridge x x ---- -_-- ---- Joplin, 140 Product Name AM 03462 ASTM D3161 ASM D6381 UL 2390 AM D7158 CSA Class F Class H Class H Class H 123.5 Glass-Seal (AR) x x x Elite Glass-Seal (AR) x x x x x Heritage x x x x x x Heritage 30 (AR) x x x x x x Heritage XL (AR) Heritage 50 (AR) Heritage Premium Heritage Vintage (AR) 12 X 12 Hip and Ridge x x 12-1/4 x 12 Hip & Ridge x x October 10, 2012 Tamko Building Products 220 W 4th Street PO Box 1404 Joplin, MO 64801 Contact Name: Kerri Eden Email Address: Kerri Eden(a).tamko.com Subject: UL Third Party Inspection Service for Florida Quality Assurance Expiration Date: October 10, 2015 Reference: File R2919 Dear Ms. Eden: This letter is to confirm that Tamko Building Products has an agreement with UL LLC to conduct audits at your plant to verify Florida Quality Control requirements at the following locations: Tamko Building Products Tamko Building Products Tamko Building Products 601 N. High St 1598 Hwy 183 2300 35th St Joplin MO 64801 Phillipsburg KS 67661 Tuscaloosa AL 35401 Tamko Building Products Tamko Building Products 7910 S Central Expy 4500 Tamko Dr Dallas TX 75216 Frederick MD 21704 Quality Control System and Products will be inspected according to Florida Product Approval Report FL1956 to ensure the manufacturer's quality documentation is well defined,fully documented and effectively implemented. A minimum of two(2)inspections per year will be conducted. This service has been established under file R2919. ULLLC 333 Pfingsten Road,Northbrook,IL 60062-2096 USA T:847.272.8800/F:847.272.8129/W:UL.com Application Instructions for FORMERLY HERITAGE®30 [TAM HERITAGE® BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Tuscaloosa,AL THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LiMITED WARRANTY FOR DETAILS. THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER. IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOiD DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES. IMPORTANT FASTENING INFORMATION: DO NOT PLACE FASTENERS ON OR ABOVE THE PAINT LiNE ON THE SHINGLE.The paint line on the shingle Is the upper-most edge of TAMKO's expanded Nail Zone. For complete details regarding TAMKO's expanded Nail Zone,see section 3 of these Application Instructions, Failure to follow fastening instructions,including but not limited to improper placement of fasteners on or above the paint line,will adversely affect coverage under TAMKO's applicable Limited Warranty.Avoid placing fasteners into the sealant strip. IMPORTANT It is not necessary to remove the plastic strip from the back of the shingles. L ROOF DECK area per 300 square feet if at least 40%and not more than 50% These shingles are for application to roof decks consisting of of venting is provided not more than 3 feet below the ridge or if a plywood or sheathing boards capable of receiving and retaining Class I or If vapor barrier is installed on the warm in winter side of fasteners,and to inclines of not less than 2 in.per foot. For roofs the ceiling in climate zones 6, 7, and 8 as recommended by the having pitches 2 in. per foot to less than 4 in. per foot, refer to 2012 International Residential Code.For more information consult special instructions titled"Low Slope Application".For roofs having your design professional.If the ventilation openings are screened, pitches greater than 21 in.per foot,refer to special instructions titled the total area should be doubled. "Mansard Roof or Steep Slope Roof".Shingles must be applied IT IS PARTICULARLY IMPORTANT TO PROVIDE properly. TAMKO assumes no responsibility for leaks or defects ADEQUATE VENTILATION. resulting from improper application,or failure to properly prepare the surface to be roofed over., 8.FASTSNSRS NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, WIND CAUTION: Extreme wind velocities can damage these dry and free from warped surfaces.It is recommended that metal shingles after application when proper sealing of the shingles does drip edges be installed at eaves and rakes. not occur. This can especially be a problem if the shingles are PLYWOOD:All plywood shall be exterior grade as defined by applied in cooler months or In areas on the roof that do not receive APA -The Engineered Wood Association. Plywood shall be a direct sunlight. These conditions may impede the sealing of the minimum of 3/8 in,thickness and applied in accordance with the adhesive strips on the shingles.The inability to seal down may be recommendations of APA-The Engineered Wood Association. compounded by prolonged cold weather conditions and/or blowing SHEATHING BOARDS: Boards shall be well-seasoned tongue- dust.In these situations,hand sealing of the shingles is required.To and-groove boards and not over 6 In.nominal width.Boards shall insure immediate sealing,apply quarter-sized dabs of TAM-PRO® be a 1 in. nominal minimum thickness. Boards shah be properly Premium SBS Adhesive orTAMKOTam-Seal Adhesive on the back of spaced and nailed. the shingle 1 in.(25mm)and 13 in.(330mm)in from each side and 1 in.(25mm)up from the bottom of the shingle.Press shingle firmly into 2.V ENT16ATiON the adhesive.For maximum wind resistance along rakes,install any TAMKO starter shingle including sealant or cement shingles to the inadequate ventilation of attic spaces can cause accumulation of_ underlayment and each other in a 4 in.(102mm)width of TAM-PRO moisture in winter months and a build up of heat in the summer. SBS Adhesive orTAMKO Tam-Seal Adhesive.Caution:ApplyONLYa These conditions can lead to: thin uniform layer of adhesive less than 1/8 in.(3mm)thick.Excessive 1.Vapor Condensation amounts can cause blistering of the shingles and may soften the asphalt in certain underlayments resulting in the asphalt flowing, 2.Buckling of shingles due to deck movement. dripping and staining.Shingles must also be fastened according to 3.Rotting of wood members. the fastening instructions described below. 4.Premature failure of roof. Correct placement of the fasteners is critical to the performance of the shingle.If the fasteners are not placed as shown in the diagram To insure adequate ventilation and circulation of air,the ventilation and described below,this will result in the termination of TAMKO's system must include inlets and outlets.This may be accomplished liabilities under the Limited Warranty.TAMKO will not be responsible with a combination of ridge and soffit vents or by using gable end for damage to shingles caused by winds in excess of the applicable vents. FHA minimum property standards require one square foot mph as stated in the Limited Warranty.See Limited Warranty on the of net free ventilation area to each 150 square feet of space to wrapper or tamko.com for details. be vented.This may be reduced to one square foot of ventilation (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 05/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamkoxom Southwest District 7910 S.Central Exp„ Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3 O (CONTINUED from page 1) FORMERLY HERITAGE®30 TAMKO HERITAGE® BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Tuscaloosa, AL FASTENING PATTERNS: 4) High Wind Fastening Pattern. (For High Wind Application 1) NAIL ZONE: The Nail Zone for standard fastening is defined as requirements)One fastener 1 in.from each end.One fastener 8-1/2 the 1-3/4 in.area beginning at 6-1/8 in.from the bottom edge of in.from each end and one fastener 16 in.from each end for a total the shingle and ending at the paint line located at 7-7/8 in.from the of six(6)fasteners per shingle.In addition to this shingle fastening bottom edge of the shingle. DO NOT PLACE FASTENERS ON OR pattern requirement for High Wind Application,TAMKO also requires ABOVE THE PAINT LINE ON THE SHINGLE. the use of TAMKO starter shingles including sealant strip at eaves and rakes.Alternatively,along rakes,cement shingles to the underlayment 2)Standard Fastening Pattern Options. and each other in a 4 in.(102 mm)width of TAM-PRO SBS Adhesive (For use on decks with slopes 2 in.per foot to 21 in.per foot.) or TAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin uniform layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts can A. Preferred Fastener Location: Fasteners should be placed 6-1/8 cause blistering of the shingles and may soften the asphalt in certain in.from the bottom edge of the shingle, penetrating through the underlayments resulting in the asphalt flowing,dripping and staining. common bond,and located horizontally as shown in the Standard High Wind Application is offered on new construction or complete Fastening Pattern diagram. tear-off applications only.It is not offered for recover applications.If High Wind Application requirements are not followed,the High Wind B. Acceptable Fastener Location:Fasteners must be placed in Application Warranty MPH,as stated on Table I in the Limited Warranty, the 1-3/4 in.nailing area beginning at 6-1/8 in.from the bottom edge reverts to the Standard Application Wind Warranty MPH limit.(See of the shingle and ending at the paint line located at 7-7/8 in.from Mansard and High Wind Fastening Pattern illustrated above.) the bottom edge of the shingle. Nails shall be located horizontally CAUTION: ALL FASTENERS FOR MANSARD AND HIGH WIND as shown in the Standard Fastening Pattern diagram. APPLICATIONS MUST BE DRIVEN INTO THE NAIL ZONE CAUTION: Fasteners must not be driven into the edge of the COMMON BOND(PREFERRED FASTENER LOCATIONS)AS SHOWN common bond area.Avoid placing fasteners into the sealant strip. IN THE MANSARD AND HIGH WIND FASTENING PATTERN DIAGRAM. STANDARD FASTENING PATTERN IN NAIL ZONE NAILS:TAMKO recommends the use of nails as the preferred method of application. Standard type roofing nails should be used. Nail 1 12-1/2" —+--12-s/8"—►' 12-1/2" shanks should be made of minimum 12 gauge wire,and a minimum PAINT PREFERRED FASTENER LOCATIONS Properly Driven Improperly Driven LINEmin diameter underdriven overdriven crooked i NAIL ZONE Asphalt ..................._.._..._.. ................................. ........................... ... ... _ Shingles 6 1/8" EDGE OF Er §I Decking COMMON 1 BOND o'l_ 1/a•nominal EXPOSURE straight,good penetration, Inadequate too deep,cuts Inadequate 5-5/8" and gush with shingle surface penetration Into shingle anchorage ACCEPTABLE FASTENER LOCATION head diameter of 3/8 in.Nails should be long enough to penetrate DO NOT FASTEN 3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick, ALONG EDGE OF ................._............_. COMMON BOND the nails should be long enough to penetrate completely through PREFERRED plywood decking and extend at least 1/8 in.through the roof deck. FASTENER Drive nail head flush with the shingle surface. LOCATION STAPLES:If staples are used in the attaching process,follow the above instructions for placement.All staples must be driven with 3) Mansard Fastening Pattern. (For use on decks with slopes pneumatic staplers.The staple must meet the following minimum greater than 21 in.per foot.)One fastener 1 in.from each end and dimensional requirements.Staples must be made from a minimum one fastener 8-1/2 in.from each end and one fastener 16 in.from 16 gauge galvanized wire.Crown width must be at least 15/16 in. each end for a total of 6 fasteners per shingle.(See Mansard and (staple crown width is measured outside the legs).Leg length should High Wind Fastening Pattern illustrated below.) be a minimum of 1-1/4 in.for new construction and 1-1/2 in.for reroofing thus allowing a minimum deck penetration of 3/4 in.The FASTENERS NAIL ZONE crown of the staple must be parallel to the length of the shingle. COMMON p BOND The staple crown should be driven flush with the shingle surface. Staples that are crooked,underdriven or overdriven are considered 6 1/8" EXPOSURE 5-518" improperly applied. Properly Driven Improperly Driven iLL-�( �7-12'�(r7-12"-a 7-38"-►�7-12"-►�7-12"-►I �1° ,s,�1, underdnven overdriven cooked Asphalt Shingles MANSARD AND HIGH WIND FASTENING PATTERN rtql Decking 2} - . (Continue Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 05/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamkoxom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2 y1 ® (CONTINUED from page 2) FORMERLY HERITAGE®30 ETA:M:K 0 HERITAGE® BUI6DING PRODUCTS LAMINATED ASPHALT SHING6ES Tuscaloosa,AL 4.UNDERLAYMENT S.APPLICATION INSTRUCTIONS UNDERLAYMENT. An underlayment must be applied over the STARTER COURSE:A starter course may consist of TAMKO Shingle entire deck before the installation of TAMKO shingles.Failure to add Starter,TAMKO 10-inch Starter or self-sealing 3-tab shingles.If self- underlayment can cause premature failure of the shingles which is sealing 3-tab shingles are used,remove the exposed tab portion and not covered by TAM Kos Limited Warranty, install with the factory applied adhesive adjacent to the eaves.Attach Products which are acceptable for use as underlayment are: the starter course with approved fasteners along a line parallel to and 1.5 in.to 3 in.above the eaves edge.The starter course should Asphalt Saturated Felt Underlayments: overhang both the eaves and rake edges 1/4 in.to 3/8 in.if drip edge • TAMKO SuperX 15TM or SuperX 30TM Underlayment flashing is not used along the eaves or rakes.If drip edge flashing is present,install shingles even with the drip edge. • TAMKO No.15 Asphalt Saturated Organic Felt For maximum wind realate oo along rakes,Install any • Any TAMKO non-perforated asphalt saturated organic felt IT°�� ta"°rsNng'°needing aaaan�°'sem°"'an"gaa ymonI and each 0.1N a 4'102 mn)wfft of TAM-PRO SBS Adhesive or TAMKO Te Seat Adhesive Undedaymem Deck • A non-perforated asphalt saturated organic felt which meets � "-"'^g� Baphaft-1 saturated fen ASTM:D226,Type I or II or ASTM D4869 — Specialty Underlayments: Drip—� • Tam-Shield®Synthetic Underlayment edge ............................................ • TAMKO Moisture Guard Plus@, TW Underlayment and TW Rake �. _ Metal and Tile Underlayment®(additional ventilation may be genera •tea' required.Contact TAM KO'sTechnical Services Department for homakeB . ------ more information.) J� R • A self-adhesive underlayment designed for use with asphalt Stan 0.1 snip mth,aaangle sanerampa ovemang self-sealing Eave Fast— Drip edge moved,Nen follow with fill eaves and mkas adhesive orated shingles which meets ASTM D1970. ships In order moffset with ma vs'to ala'If no drip edge positioned 1-1W to 3• first shingle mums. flashing Is present.If drip along eaves from am edge edge flashing Is present or rake edge For Asphalt Saturated Felt Underlayments: install shingles even Win drip edge. Apply the felt when the deck is dry.On roof decks with slopes 4 in. per foot and greater apply the felt parallel to the eaves SHINGLE APPLICATION:Start the first course with afull size shingle lapping each course of the felt over the lower course at least and overhang the rake edge 1/4 in. if drip edge is not present. If 2 in.Where ends join,lap the felt 4 in.If left exposed,the felt drip edge is present,align shingle edge with drip edge flashing.Cut may be adversely affected by moisture and weathering.Laying 10-3/8 in.from a full shingle to form a shingle 29 in.long.Use this of the felt and the shingle application must be done together. to start the second course(see diagram below).Cut a 23 in.long For All Other Specialty Underlayments: shingle to start the third course.Use the remaining 16-3/8 in.piece of shingle to start the fourth course and use the remaining 10-3/8 On roof decks with slopes 4 in. per foot and greater apply in.piece to begin the fifth course.Continue up the rake in as many the underlayment parallel to the eaves in accordance rows as necessary using the same formula as outlined above. with underlayment written application instructions. The underlayment should not be left exposed for a longer period of time than is specified in the underlayment's written application instructions.The final roof covering must be installed before the structure is exposed to adverse weather conditions,such to-s/e" as wind driven rain,high wind,hail,ice storms,etc. In areas where ice builds up along the eaves or a back-up of water courses tgale 1oaie 2 from frozen or clogged gutters is a potential problem, TAMKO's Moisture Guard Plus®, TW Metal and Tile Underlayment or TW 2a ' Underlayment (or any specialty eaves flashing product) may be 29 464- 23" applied to eaves,rakes,ridges,valleys,around chimneys,skylights ' or dormers to help prevent water damage. Contact TAMKO's rake Technical Services Department for more information. 10-3/8" Substitute products as shingle underlayment should not be used. sm coarse P 9 Y 23"' t8 3/8"'. 4th course 4 3/e 3rd course 23 c 2nd course I at course 10-3/8am r—save ► (Continues!) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 05/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.eom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3 ® (CONTINUED from page 3) FORMERLY HERITAGE®30 TAMKO HERITAGE® BUI6DING PRODUCTS LAMINATED ASPHALT SHINGLES Tuscaloosa, AL The butt of the shingle should be aligned with the top edge of the multi-layered shingles.The performance of the sealant feature may sawtooth of the underlying shingle for a 5-5/8 in. exposure(see be compromised, preventing the shingles from sealing properly.It is shingle application drawing illustrated on this panel). When you acceptable to install laminated shingles over existing three-tab strip make your final cut at the roof's edge,flip any pieces that are Bin.or shingles which are flat and essentially intact.Nail down or remove curled longer back onto the roof.These pieces can be worked in anywhere or broken shingles from the existing roof.Replace all missing shingles without creating zippers or color variations. with new ones to provide a smooth base.Shingles that are buckled NOTE:Do not align joints of shingle courses when working in cut usually Indicate warped decking or protruding nails.Hammer down all pieces.Joints should be no closer than 4 in.from one another. protruding nails or remove them and refasten in a new location.Remove all drip edge metal and replace with new. - �n first Nese mum sa Ingle to -and a103leh If re-roofing over an existing roof where new-flashing is required to a length length. protect against ice dams(freeze/thaw cycle of water and/or the backup 29" 10318' of water in frozen or clogged gutters),remove the old roofing to a point at least 24 in.beyond the interior wall line and applyTAMKO's Moisture Guard Plus®,TW Metal and Tile Underlayment,or TW Undedayment. Contact TAMKO'sTechnical Services Department for more information. Measurements will vary when nesting over an existing 5 in.exposure single roof:Call TAM KO Technical Services for further information. The nesting procedure described below is the preferred method for reroofing over existing metric size shingles with a 5-5/8 in.exposure. See description below: 2.�in,aayplica ion With Mull length tingl10 e.lengw6. Starter Course:Remove the tabs and an additional portion from the As you can see,three shm91e6 Will two cuts head of a full size shingle so that its height is equal to the exposure of make Ne course=. the existing shingles.Position the resulting strip over the existing roof edge(with the factory-applied adhesive strip along the eaves). Cut 3.cenunar t the roars your edge,acre=s me root•When you long your approximately 6 in.from the rake end and apply the remaining portion at final cutnu et me roofs edge,flip any pieces that are e'or longer back onto the roof.These paces can be worked In anywhere without the eaves.Continue the starter strip by applying full length shingle strips creating zippers or color variations. NOTE Do not align joints of shingle courses when working In cut to height as above,evenly along the existing roof at the eaves.The cut pieces.Joints should be no closer than V from one another. existing roof should overhang the eaves far enough to carry water off into the gutter.If this is not the case,cut and apply the starter B.LOW SLOPE APPLICATION strip so that it will provide sufficient overhang for proper drainage. On pitches 2 in.per foot to 4 in.per foot cover the deck with two FrstCourse:Removean amount from the butt edge ofafull-size shingle layers of underlayment. Begin by applying the underlayment in a so that the remaining portion of the shingle fits between the butts of the 1/2-sheet width along the eaves and overhanging the drip edge existing third course.This course must also be applied evenly along the by 1/4 to 3/4 in.Place a full-sheet width over the 1/2-sheet width eaves edge of the new starter strip. starter piece,completely overlapping it.All succeeding courses will be positioned to overlap the preceding course by 1/2-sheet width. Existing shingles If winter temperatures average 25eF or less, thoroughly cement the laps of the entire underlayment to each other with TAM-PRO 5 5/8 or TAMKO Plastic Roof Cement from eaves and rakes to a point 131/a y tai of a least 24 in. inside the interior wall line of the building.As an /a alternative, TAMKO's Moisture Guard Plus®, TW Metal and Tile E Underlayment, or TW Underlayment self-adhering underlayment may be used in lieu of the cemented felts. Drip edge Drip edge 7.MANSARD ROOF OR STEEP SLOPS ROOF New shingles If the slope exceeds 21 in. per foot (601, each shingle must be sealed with TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive 5 5/8' 5 5/8'exposure immediately upon installation.Quarter-sized dabs of cement must exposure be applied to shingles with a 5-5/8 in.exposure,use 6 fasteners per shingle.See Section 3 for the Mansard Fastening Pattern. Second and Succeeding Courses:Remove 10-3/8 in.from the rake 8.BE-ROOFING end of the first shingle in the second course, and continue with full width shingles for the remainder of the course,placing the top edge of Before re-roofing,be certain to inspect the roof decks.All plywood shall each new shingle against the butt edge of the old shingle in the course meet the requirements listed in Section 1. above.This method should create an exposure of 5-5/8 in.afterthe first It is not recommended to install laminated asphalt shingles directly course.When beginning the succeeding courses continue to follow the over existing laminated shingles due to the unevenness of the existing Heritage application instructions.(See section 5). (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 05/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4 ® (CONTINUED from page 4) FORMERLY HERITAGE®30 TAMKO HERiTArsE® BUIMING PRODUCTS 6AMINATED ASPHA6T SHINGLES Tuscaloosa, AL 9.VALLEY APPLICATION 10.HIP AND RIDGE FASTENING DE1'A16 Over the shingle underlayment,center a minimum 36 in.wide sheet Apply the shingles with a 5-1/8 in.exposure beginning at the bottom of TAMKO Moisture Guard Plus®,TW Metal&Tile Underlayment, of the hip or from the end of the ridge opposite the direction of the or a minimum 50 Ib.roll roofing in the valley.Nail the underlayment prevailing winds.Secure each shingle with one fastener on each side, only where necessary to hold it in place and then only nail the 5-5/8 in.back from the exposed end and 1 in.up from the edge. outside edges. TAMKO recommends the use of TAMKO Hip & Ridge shingle IMPORTANT.PRIOR TO INSTALLATION,WARM SHINGLES TO products.Where matching colors are available,it is acceptable to PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces. SHINGLES TO FORM VALLEY. The length of the fastener should be long enough to penetrate After valley flashing is in place: through the roofing material and 3/4 in,into the wood decking or • Apply the first course of shingles along the eaves of one of the completely through approved plywood. intersecting roof planes and across the valley. IMPORTANT: PRIOR TO INSTALLATION, CARE NEEDS TO BE Note:For properflow of water overthe trimmed shingle,always TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE start applying the shingles on the roof plane that has the lower BENDING SHINGLE IN COLD WEATHER. slope or less height. Direction of prevailing wind • Extend the end shingle at least 12 in.onto the adjoining roof. Start 5-1/8"exposure Apply succeeding courses in the same manner,extending them here— across the valley and onto the adjoining roof. Fastener • Press the shingles tightly Into the valley. III P5-5/8" ' II Start • Use normal shingle fastening methods. here 5-1/8e exposure Note:No fastener should be within 6 in.of the valley centerline, THESE ARE THE MANUFACTURER'S APPLICATION and two fasteners should be placed at the end of each shingle INSTRUCTIONS FOR THE ROOFING CONDITIONS crossing the valley. DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES • To the adjoining roof plane,apply one row of shingles vertically NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING facing the valley and 2 in.back from the valley centerline. DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW Note: For a neater installation, snap a chalkline over the THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE shingles for guidance. UNDER THE LIMITED WARRANTY. SEE THE LIMITED • To complete the valley, apply shingles on the adjoining roof WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS plane by positioning the tip of the first shingle of each row at REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE the 2 in.point from the centerline where the edge of the vertical CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT shingle has been applied,covering the vertical shingle. 800-641-4691. Valley centerline Minimum 36'wide sheet Information Included in these application Instructions was current at time of printing.To of Moisture Guard Plus, MetalTile Extra nail in obtain a copy of the most current version of these application instructions,visit us online or or 50 Ib.orr end of shingle at tamko.com or call us at 800-641-4691. heavier roll roofing Extend end shingle 12'-18'beyond valley centedine f TAMKO®,Moisture Guard Plus®,Tam-Shield®,TAM-PRO®and Heritage®are registered / trademarks and SuperX 15 and SuperX30 are trademarks of TAMKO Building Products,Inc. Undedayment � No fasteners within 6'of centerline Place tip of shingle on the edge of the vertical shingle,2 inches back from valley centerline and covering the vertical shingle. FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT 800-641-4691. Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 05/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 5 Florida Building Code Online http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVX... � � S 05 Florida Department BCLS c t'1 c d Home � Log In j User Registration Hot Topics j Submit Surcharge ! Stats&FaCts � PublicationsI FBC Staff � BGIS Site Map i L1nks I Search Busines f,'� Product Approval Professit�al S usER:Public User Regulation Product Anproval Menu>Product or Application Search>Apollcation List>Application Detail � oa FL# FC3664-R5 Application Type Affirmation— Code ffirmationCode Version F2Q10= Application Status Approved Comments ' Archived Product Manufacturer TAMKO.Bhililing PoiiUcts;In` Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden @tamko.com Authorized Signature Kerri Eden kerri_eden @tamko.COm Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644' Ext 2305 kerri_eden@tamko.com 20 Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Test Report Testing Lab PRI Construction Materials Technologies,LLC Quality Assurance Entity Underwriters Laboratories Inc. Quality Assurance Contract Expiration Date. 03/26/2013 Validated By Robert J.M.Nieminen,PE Validation Checklist-Hardcopy Received Certificate of Independence FL3664 R5 COI PRI CMT Cert of Indeoendence.odf Referenced Standard and Year(of Standard) Standard Year ASTM D 1970 2001 Equivalence of Product Standards Certified By I affirm that there are no changes in the new Florida Building Code which affect my product(s)and my product(s)are in compliance with the new Florida Building Code. 1of 2 .3/2/2015 9:54 AM Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVX... S Documentation from approved Evaluation or Validation Entity Yes !'No '':ri N/A Product Approval Method Method 1 Option B - Date Submitted 10/12/2011 Date Validated 10/12/2011 Date Pending FBC Approval Date Approved 10/20/2011 Date Revised 03/04/2013 Summary of Products FL At Model,Number or N meli, Description 3664.17W Uncle Ir aymeneet° A self-adhering rubberized asphalt sheet membrane. Limits of Use Installation Instructions Approved for use in HVHZ:No FL3664 R5 II tw underiayment apo ins.Ddf Approved for use outside HVHZ:Yes Verified By:ICC Evaluation Service,LLC Impact Resistant: N/A Test Reports Design Pressure:N/A FL3664 R5 TR PRI TW Underlavment Ddf Other:Membrane should not be applied to damp,frosty or contaminated surfaces.Membrane should not come into contact with products containing coal-tar pitch.Not approved for use in High Velocity Hurricane Zones. Back Next Contact Its::1940 North Monroe Street Tallahassee FL 32399 PhonPhon 89(1-487.10424 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida,::PrNa(:y Statement::Accessibility Statement::Refund Statement . _ Under Florida law,email addresses are public records.If you do not want your a-mall address released in response to a public-records request,do not send electronic _ mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section . 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address f they have one.The emads provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here-. Product Approval Acmpts: ® o sccurityAtriTKtcJ, 2 of 2 3/2/2015 9:54 AM.. i t a CONSTRUCTION MATERIALS T E C H N 0 L 0 6 1 E S ACCREiwrim RAT E LABORATORY T REPORT TEST Report for: Tamko Building Products,Inc. Date: November 8,2007 220 W.4th Street Joplin,MO 64802 Attention: Aaron Phillips Product Name: TW Underlayment Manufacturer: Tamko Building Products Date Received: October 17,2007 Source: Tamko Building Products PRI Project No.: TAP-193-02-01 Metro Dade Notification No.: PRIO7224 Subject: The purpose of this project was to determine performance properties of Tamko TW Underlayment for compliance with the requirements of ASTM D 1970-01, Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for ice Dam Protection. Test Methods: The test methods used included those found in ASTM 1970:Standard Specification for Self- Adhering Polymer ModNed Bituminous Sheet Materials Used as Sleep Roofing Urrderiayment forlce Dam Protecction or referenced in ASTM D 1970 including: ASTM D 228:TestMethods for Asphalt Roll Roofing, Cap Sheets,and Shingles,ASTM D 903: Test Method for Peel or Stripping Strength of Adhesive Bonds,ASTM D 1204: Test Method.for Linear Dimensional Changes of Nonrigid Thermoplastic Sheeting or Film at Elevated Temperature , ASTM D 2523:Practice for Testing Load-Strain Properties of Roofing Membranes,ASTM D 4073:Test Method for Tensile-Tear Strength of Bituminous Roofing Membranes,ASTM D 5147: Test Methods for Sampling and TesBng Modr6ed Bituminous Sheet Material and ASTM E 96:Test Methods for Water Vapor Transmission of Materials,ASTM D 4521:Standard TestMethod for Coefficient of Static Friction of Corrugated and Solid Fiberboard. Product Afull factory labeled roll of TW Metal and Tile Underlaymentwas supplied byTamko Building Sampling: Products. TAP-19302-01 PRI Accreditation:IAS-ES TL-i W_State of Florida TST 58784Metro-Dade 06-1116.02;CRRC The test results,opinions,or Interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made wdhcut the clienYa permission.This report shag not be reproduced except in frill without the vw t6en approval of this laboratory. PRI Asphalt Tec hnotogies,Inc.assumes no responsibility nor makess pmforrrt nworvtarrardy statement for this material or products and processes containing this material In connection with this report. PRI Constrt> M Matelot;Ter MN1es,LLr—6408 Badger Dm® Tampa,FL 33610 Tet 613.5115777 Fac 8t3.61t5840 eaW me%rie dadng@pricm coin Wdeta:hdl Aww.pievhetrom Tamko Building Products Laboratory Test Report for TW Underlaymert PRIO7224 Page 2 of 3 Results of Testis Property ASTM Test Method Result ReqUirement Thickness,mils D 5147 43 40 mitt Matdmum load at break @ 73.4±3.6°F,IbfAn Longitudinal D 2523/D 1970 28.1 25 min Transverse 28.7 25 min kWmum elongation at break @ 73.4+3.6°F,% Longitudinal D 2523 30.0 10 min Transverse 17.2 10 min Adhesion to plywood @ 75±2°F,Ibf/ft D 903/D 1970 56.7 12 min Adhesion to plywood @ 40±2°F,Ibf/ft D 9031 D 1970 73.3 2.0 min Thermal Stability,in D 1204/D 1970 0.0 0.1 max Low Temp Flex at-20°F,Pass/Fail D 1970 Pass No cracidng Waterproof integrity,Pass/Fail D 197017.9 Pass No waster Year Resistance,lbf Longitudinal D 4073/D 1970 48.3 20 min Transverse 41.7 20 min Moisture Vapor Permeability,U.S.Perms E 96 0.04 0.1 max lrw.Water(SW) Seff-Sealabittiy,Pass/Fail D 1970 Pass No water Waterproof integrity of lap seam, D 1970 Pass No water Pass/Fail Slip Resistance @73°F,pnclined Plane coefficient D 4521 0.78 z No. 15 Organic of static friction) felt x0.78 Unrolling @ 40 and 140°F,PasslFali D 1970 Pass No damage Statement of Compliance: The product tested complies with all of the requirements of ASTM D 1970: Standard Specification for Self- Adhering Polymer M minus Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection. Signed: C umpeitin Lebo story Technician Date: f� IJ ,2oDY Signed: Signed: Donald 6.PjhMio gu n President Ftortda R ofesstonat Enginmr J PE No.:661134 Date: �!/���d � Date: Al!I� Lo TAP-193-02-01 PRI Axreditations.IAS-ES TL-789;State of Florida TST 5678:Metro-Dade 06.1118.02 CRRC The test results,opinions,or Interpretations are based on the material supplied by the client. This report Is for the exciushre use of stated client.No reproduction or facsimile in anyform can be made without the cllents permission. This report shall rot be reproduced except In full without the written approval of this laboratory. PRI Asphaft Technologies,Inc.assumes no responsibility nor makes a perf m ance orw mmty statement for this material or products and processes containing this material in connection with this report. PRI Cm*ucfim taiah Tedwbgies,LLC.6408 Bedgw Detre Tmnpe,FL 33610 Tet 9136215777 Fac:BIM-94 a-mad mate+iehWd ng@*mL=n webSfe:htWJAw w.pfg8*wRoom Florida BoUdin Code Online htiP;/www.foridahuil oxFIPr/ r aPP_dtl.asPx7 aranl=w(iEV(Q --• ' ' � � t 6 " 'a • if AOrp,tL)prM ,Ct SCIS Home I Lou 151 Oser REsmuon I flet%ilitS SubMT SURharge Stet&Fails i rV fttbns Fac SIarr 6cis um Map 1 Lml6 Seat[h Bus-ine5 al Product approval USER:Puck User Profess! Re9dation . Em9uct Aovnr�al Manu>fratlu[t or AonN.�[k+n bnn.C)t:•FppGcatbfLLSt--Aprrlln.rL,n Cnea7 ' FL 4 FL12570-RZ Application Type Revision Code Verslon 2p10 Application Status Approved 'App�oved by DUA.Approvals by ICA shall be reviewed rind rdLIrIed I by the POC and/or thtr Commission If necessary. Com mcriL•s Archived Product Manufacturer Sun Tek Mfg Address/Phone/Emall 10303 General Dr Orlando,FL 32524 a1JC^ (407)859-2117 jrruaner-O.run-tek.com Authorized Signature .lames Feudner engineering @.5un-tek.COM Technical ReprasenLaUVe James Feudner- Address/Phone/Email .113303'General Dr Orlando,FL 32034 en glneerl ng@sun-tek.Oom Quality Asyurarice ReprCsentative James Feudner AddrosgPhone/Small '10303 General Dr Orlando,FL 37924 (,107)859-2117 Ext 111 englneeringasun-tek.cam Category Sky Lights Subcategory skylight Compliance Method Certirrcalion Mark or listing Certification Agency National Accreditation&Management Institute, Validated By National Acrxddltatlon&ManagcmcnL Inalitute, .. Referenced Standard and Year(of Standard) Standard veer TAS Z01 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards. Certified By 1'of 3 5/29/2013 11:24 AM I PloOda Builft Code Online htlp://www.floridabuilding.org/pr/pr app dtl.aspx7pafanr�GEVXQ.., Product Approval Method Method i Option A Date Submitted 03/14/2012 Date Validated 08/17/2072 Date Pending FDC Approval Date Appraved 08/20/2U12 Summary of•Products.... _ —_ -•• -___.._._ _..:. FL# Madeli!dumber or Name Descriptidn. 12570.1 CMA-D curb mounted polyrartionate bubble with welded aluminum ring Llmits of Use _-- t Certification Againcy CertIlIMe Approved for use In HVHZ:Yes I FL12570 92 G CAC CMALNJIOIIQU Dff Approved for use outside HVHZ:Yes ;quality Assurance Contract Expiration bate Impact Resistant.-Yes 11/30/2014 pevign Pressure:160/-60 :Installation Instructions Other:' FL12570_112 II CMADhistallsBCrS,pdf Verifled By:Jams D_Wells In P.E.P.E.#53616 Created by Independent Third Party,Yes Evaluation Reports FL12570 R2 AE 5 14 12 CMAD Approvee Evaluation Report.Ddf Created by Independent Third Party:Yes 12570.2 1.HSF Self flashing aluminum frame with polycarbonate bubble. Limits of 1790 Certification AgenCy Certificate Appraved for use in HVHZ:Yes I FL17.570 R2 C CAC HSFNIO11QU7(7 p 1f1f' Approvdd for uee outside HVHZ:Yes Quality Assurance Contrac[Expiration bate I Impact Resistant:Ycs 111/30/2014 Design Pressure:+60/-60 I Installation Instructions i. Other:max Size no,46-5 x 46.5 F1.12570 R2 II HSFlnstWjaag;lS.nrlf• f Verified fly-3ames D.Wells Jr.P E.P.E.#53616 Created by Independent Thlyd Party:Yes I Evaluation Reports j FL125'10 R2._AE-5 7.1 12 HSF Approved Prud Eval Renort.ndf Created by Independcfrt Third Party:Yes ... ---_........ 12570.3 ICMG Curb mounted glass Impact rated bkylighl• Limits of Use ^.M ertIflcation Agency Cemocate, Approved for use in HVM7:Yes rL12570 R2 C CAC ICMGNI00,6723-R4(ZLodr Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date impact Resistant:Yes 04/30/2014 Design Pradsure:+601-60 'Installation Instructions Other:max size Ko.46.5 x 46.5 1 Fr 12.5!0 R2 II ICMGinsL•altsDCIS.odr 1 Verifled By:James P.Wells Jr.P.E.P.E.053616 Created by Independent Tnird Party:Yes Evaluation Reports FLL2570 R2 AE..Z, 12 ICMG Approved Fvaluatlon ' 'reoort•ndF i CrtmWd 1jy Independent I hlyd Party:Yes 12570.4 I ISFG [Self flashing Impact rated plass si Vllght Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FI.12570 R2 C CAC,ISFGNIQO§21.4-R4.ndf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/201.1 Desian Pressure:4-60f-60 Installation Instructions Other.max size 46.5 x 46.5 FL12570—RZ_I7 i5EGlnstallsBCIS.odf Verified By:3ames D.Wells.3r.P.C.P.1:.053636 Created by Independent Third Party:Yes Evaluation Reports hL125��7 17 12 ISpG Aoorovetf Product . I�V,ayQtlon Report-adf (treated by,Independent Thlyd Party:Yes 12570.5 hiD CMA Curb mounted polycarbonate bubble with welded { i aluminum ring. 2 of 3 5/2)/201311:24 AM I Florida Willing Code Online http://www.floridabaiIding.org/pr/pr_4pp_dil.aspx?ptrani--wGEVXQ... Limits of Use 1 Certification Agency Certificate JI Approved'for use in HVHZ:Yes I r•1"..SYO R2 C_CAr MnrMANT00¢216-R4,ld 1 Approved for use outside HlfHZt Yes !Quality Assurance Contract Expiration Date• impact Resistant.Yes 104/30/2014 Design Pressure:t601-60 I Installation Instructions Other.Max size 22.5 x 46.5 FL1Z570 R2 1T M2CMA!nstal1zk9 S.odf 'Ver!fled By:James D.Wells Jr.RE:Ke.453616 Created by independent Thlyd Party.Yes . ! Evaluation Reports FL12570 RL AE 6 6 12 Approved EL:CMA•Pred Cual, Report o .Odi' Created by lndcpondcnt Third Party.Yes . �eaCtr Kota rantact Us::11±Q•.North Moome Strret.l5;bhsssce FLj2J99 Ptrnns;.,85h de7•1a24 I he Slate orFbdda Gan WEED emPluyer.Cu W,ult[2pn7-aQlpsete of Flo rile r;pry�y 51 tt7ms�::hm .s ty StalemQ+R:e Qgp�l tet• mnnt Under Florma Lbw,emailaddre:esare public recomz lryou do not want your e•rttad adder„5 rnkased In mspome to d pobk-mcards-squc-t,do not send r.bctmnid mail to Us entity,lnctnnd,contact the drrree by phony or try traditional mart If you have any qunrdlons,pkaue contact 850,487.1395•ipiaauam to . Stxtlon 455.295(1),Fptda a6ltut",effective ottober 1,[U11,kewnr.tamed uaderehoptn 455,n$.must pmv lee the Department wnh'on emnanddres r tlley havt one.Dhe ema15 pmvkW may ba reed rororriectl communlcatton with the kemte.I luwevef emaa adpr;w ss arc public rdwrd.R you do not wish to 5r.t7tily a personal address,please rpoVldn the Department with an emai addM5 which can be ncde dvdldbhr lv 010 public.TO determine tf you area kwiu9m vada Chapter 455,FS.,pleasg dIct:ligir— • Prood�du�7ct Approval Aacepta: arrnrit•srrrRecs•. 3 of 3 5/29/201. 11.24 AM I Sun-Tek Manufacturing,Inc. INSTALLATION INSTRUCTIONS 10303 General Drive POLYDOME SERIES Su-InaTekOrlando,FL 32824 MODEL HSF 407/859-2117 S K Y L 10 H T S wvvw,Sun-Tek,com CtrstomerService@Sun-Tek.com 7 07- m Fastener5Khcdule _1 Frame to j Deco to Deck Frame tng,ne�r of liecord. _ :Rx l" }'6x'�"H.gx Idrs:r• 11. F. 't> 't: '1,1: Finished Pan Head iicedsrdf Profes!:onzi:Lngineor Scre'A', D41Gn Srr.,Ws ppealtrg Mltson " 9 idv.S3G16 Size Roof (Drywill? Center tong 511011 Long Short Code • Opening Dimension) spacing wide, sidt- Sime Side J K I wells Consulting LLL: — 1453 tut;rwi t.wh.-• 1430 14`/x"x 301Y 1361"x 29'(2" 16" Oviedo,FL 32765 (407'496-5499 1446 14'•."x4h!•r" li'9"x.i4'i' 16' (erli(iialpcf ' Aviiwri,gtior,No.27162 2222 22:5"x 22'h' 21 Wx 21 r/•" 24" 5 5 5 S You will need: 2230 221n"x W.' 211z)k 2q%:' 24" hammer Swalarliin'!A5r)e 2236 22%x 365' 71 J x 31I% 24" •keyhole saw tine ineacurp ^ •skill saw chalkline or siraigh!edytc 2246 )11-1'x 01)" 21 WX 45!1:"_ 24" 8 5 E3 5 nails ttowel of r.;0k gt!n 3030 3D::"x30W 7.91:"x 2916° 16"or 32" Hill Utility knife 2 x 4's mio 3U:'x4o!c' 291,"x45':'.' I6"oi37.' a �e a 0 ForLight Tutintet: RECOMMENDEDSEALAtTS' ;,," y:, 0 7 8 or 10 penny nail,, 10095 Silicone X636 3G.:x 36/.•" 'i5 h"x 55 s 16 yr 32" ? 7 7 -^••. ^ plywood or drywz Il .• sediallt]app!oved fol use on 41116 _I6"'..5�< Gy3n4 45Y)k 4511 ;6",32•,41;" 4 A Ma 8 a pojyrarfsoiyaL=(Cama[I Suii.-rck ST51000(Sun-Tek exclusive)Rutyl tubber mldnt/caulk FF�ILURET0 FOLLOW RECOMMENDED INSTALLATiON PROCEDURES MAY VOID WARRANTY Please read instructions completely before beginning. 'r1A " Deck and roofing felt should already be installed. '•r r�\ < < rr rr r1 Inspect skylight for damage before installing.Peel back r \ r protective P106tic to inspect dome.if skylight is damaged,do not install.(Tease contact your supplier for information on a i r rr replacement. rrr ' rr r � r1 � r 2 To properly position skylight between tru5sesfrafters,locate the r r roof opening from the underside of the decking.Drill holes or r rr drive nails to mark corners.(if this area is not accessible,locate the ceiling joists from inside the house,mark and cut opening in ceiling,then mark roof opening.) 3 Remove shingles 6-B"out from roof opening. Before cutting roof opening,check meastirements against size chart.Shap a chalkline from corder to corner,or draw line with a straightedge,then cut roof op¢ning. 4 Frame roof opening cuing 2 x 4's"headers•cut two 2 x 4's to fit `1tdt�pAID WW,-C—,, j the actual distance between trusses/rafters and nail into place. ai If applicable,cut ceiling opening and build tunnel framing. - 53616 See"Light Tunnel installation Instructions," Y /t STATE Of r#�� Y ti frr B••s11� 1 i S Shingle up roof to bottom of roof opening. 6 Apply a 1/2"wide bead of caulking,set back 7"from the � roof opening around the entire opening.Set a second'• 6 wide bead around the entire opening,set 1"back from the first bead.Sealant applied too close to the opening may"ooze"into the opening.Can also use 3"wide x:fir' thick butyl tape,if compatible,set 1/2"back from opening, 7 Set skylight over.opening.Screw into place through the pre-drilled holes in the flange with the#8 x 1"phillips pan head screws provided(See FaslenerSchedule).Cover the head of each screw with sealant. IMPORTANT. Bottom flange of skylight MUST go on top of shingles._ Now shingle.up sides and across top.Place shingles,as far - in as possible,but be careful not to nail iflrough skylight V.- flange, 9 Sotinrn flange will still be exposed:we recommend N 11 leaving it this way.If you decide to put a"false shingle"overit,be careful not to nail through skylight flange, -- - 1 0 Interior finishing: Run drywall(or other finishing.material) up the inside face of the skylight curb.Slip the drywall up until it bumps against the ledge in the top of the curb. Engineer of Record: .tames D.Wells,Jr.,P.C. Yrorts,;onal Enginper No.53616 is J b L V16b Consallinq I.I.0 ,l; c 1453 ArbltusCntle st-'k•. Oviedo,FL 32765 (4U/)496-5.189 K, ('arrlficate of spa Avllo natio-)Nn.1.71F,2 `Ott 11111111"d u%��` I � ���' '"f'r!><e����•ti✓� fir IFNo. 53616 rstd, 'ir.u� .;<:•.. r 1 Y'.:p ,.k�,Z••. .•_er:1 l.�i_,*w:V 54.50_._..__._.._......_.... .__.... A. •- 4.00 ,--� 6.75 6.75 C-0 Ert.)inccratfi_t.orci: —�~6,75 a.6 —� C JJmr:I r•Wr.Ils,J;,PF, � 6 OQ Fro(C'.•liprt:ltFtwcrit,C�t'r � ..___ I. I ` Tq llwl.'A10s,CnnsuitingLLC Nis k iu,C,rcie } _- Uvit:do,f L S27F5 _ c\I (407)496-5439t— LC:lik to u! Awhoriwtion No.27162 N j � 32 FASTENERS FRAME TO DECK (6 i i DESIGN P€?ESSU� RAT.INIG ___ ... / +_60 PSF cci U") �•�Q•- LE:LRGE Ml SLE IMPACT RE S)S'fANCE = -- U.) fr, h• {p 32 FASTENERS DECO RING TO FRANE .. . ......_........... No. 53616 OUTER OOPAC.OrI3 PO'_YCARDONATG � -•� (GE LEXAN OR SHEFFIELD HY200'GP") l I grA17 OF Li (j it INNER DOME M0 i; Yt7lYC.Rt;xt3NtilP;(GF 1,l=XAry I OR of Igi-FIruO i P(7.np j; 1 li tu ct ii Lt {i d Q I DESIGN PRESSURE RATING I ( g I; +-60 P5F ii II ;LARGEMISSLEIMPACT RESlSTANCEI ( II 'i ;i li t LL 0 O 11 V 1f :j a is 4 .. •.i �__ 1 &.B titin PE+tEtBliOn i —•• _ ..__ _ _.� " —ROOF DECK N X 1°PHILLIPS PAW HEAD