HomeMy WebLinkAboutProduct Approval Florida Building Code Online http://ww*.floridabuilding org(pr/pr app_ tl.aspic?param=wGEVXQ...
Hoilda Depaftentd .BCIS Home Log In User Registration Hot Topics. Submit Surcharge Stats.&Facts + Publications FBC Staff BC35 Ste Map links Search
Busines
Professi IO.Pr.0.1
uctApproval
SPublic User
ala tlldt1on
Product Approval Menu>Product or Application search>ADDIIcation Ust>AppEcation DetaB
FL#
Application Type Revision
Code Version p:r
Application Status Approved
*Approved by DBPR.Approvals by-DBPR shall bee `.and ratified
by the POC and/or the Commission If necessary } .
Comments
Archived
0
Product Manufacturer TAMKO"Building Products,Inc.
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com ssyy :
Technical Representative Kerri Eden 7rj0^ ��
Address/Phone/Email PO Box 1404" . ' ;F
Joplin,MO 64802 C �� 4Z
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Quality Assurance Representative..' y,
Address/Phone/Emall
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency UL LLC
Validated By Robert J.M.Nieminen,PE
'Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year .
ASTM D3161 2006
ASTM D3462 . 2007
ASTM D7158 2007
Equivalence of Product Standards .
Certified By
Product Approval Method" Method i Option A
1 of 4 11/7/2013 8:49 AM
Florida Building Code Online http://www'.floridabuilding org(pr/pr app_dtl.aspx?param�vGEVXQ...
Date Submitted 09/27/2012
Date Validated 10/15/2012
Date Pending FBC Approval
Date Approved 10/16/2012
Summary of Products
FL# Model,Number or Name Description
1956.1 Elite Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.odf
Approved for use outside HVHZ:Yes FI-19S6'R8 C CAC UL certificatlon 10-11-12.1)
Impact Resistant:N/A Quality Assurance Contract Expiration Date
Design Pressure:N/A 10/10/2015
Other:Asphalt shingles shall be used only on Installation Instructions
roof slopes of 2:12 or.greater.Nails must be used FL1956 R8 II glass seal elite app Inst aprii 10.pdf
as the method of attachment. FL1956 R8 II glass seal elite apo inst f april 10.pdf
FL1956 R8 II'TAMKO Glass-Seal Elite Glass-Seal(Frederick Joplin
Tuscaloosa).pdf
Verified By:Robert Nleminen 59166
Created by Independent Third Parry: No
Evaluation Reports
Created by Independent Third Party:
1956.2 Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL1956'R8 C CAC Tamko Sery Conf FL 1956 2012 odf
Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10-11-12 pdf
Impact Resistant:N/A Quality Assurance Contract Expiration Date
Design Pressure:N/A 10/10/2015
Other:Asphalt shingles shall be used only on-. Installation Instructions
roof slopes of 2:12 or greater.Nails must be used FL1956 R8 H glass seal elite app Inst april 10 pdf
as the method of attachment. FL1956 R8 II TAMKO Glass-Seal Elite Glass-Seal(Frederick Joplin
Tuscaloosa).pdf
Verified By: Robert Nieminen PE 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.3 Heritage A dimensional asphalt"shingle.
Limits of Use Certification Agency Certificate.
Approved for use In HVHZ: No FL1956-118 C CAC Tamko ServConf FL 1956 2012.pd
Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification -10-11-12 pdf
Impact Resistant:N/A Quality Assurance Contract Expiration Date
Design Pressure:N/A 10/10/2015
Other:Asphalt shingles shall be used only on Installation Instructions
roof slopes of 2:12.or greater.Nails must be used FL1956 R8 II heritage app Inst-sept 12.pdf
as the method of attachment. FL1956 R8 II heritage ago Inst frederick pdf
Verified By: Robert J.M.Nieminen FL 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
"1956.4 'Heritage 30 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012 pdf
Approved for use outside HVHZ:Yes FL1956 R8 C CAC OL certiflcatlon lU-11-12 pdf
Impact Resistant:.N/A Quality Assurance Contract Expiration Date
Design Pressure:N/A 10/10/2015
Other:Asphalt shingles shall be used only on Installation Instructions
roof slopes of 2:12 or greater.Nails must be used FL1956 R8 II heritage 30 aop Inst-amil 10 pdf
as the method of attachment. FL1956 R8 II heritage 30 apo Inst f aprll 10 pdf
Verified By: Robert Nieminen PE 59166
Created by Independent Third Party:No
Evaluation Reports
Created by Independent Third Party:
1956.5 Heritage 50 A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012 pdf
Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10-11-12 odf
2 of4 11/7/2013 8:49 AM
Florida]Building Code Online' http://www.floridabuilding.org(pr/pr app_dtl.aspx?param--wGEVXQ...
Impact Resistant:N/A Quality Assurance Contract Expiration Date
Design Pressure:N/A 10/10/2015
Other:Asphalt shingles shall be used only on Installation Instructions
roof slopes of 2:12 dr.greater.Nails must be used FL1956 R8 II heritage 50 apo inst april 10 pdf
as the method of attachment. FL1956 R8 II heritage 50 apo Inst f aprll 10 pdf
Verified By:Robert Nleminen PE 59166
Created by Independent Third Party: No .
Evaluation Reports
Created by Independent Third Party:
1956.6 Heritage Premium A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate i
Approved for use in HVHZ:No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.0
Approved for use outside HVHZ:Yes FL1956 R8.0 CAC UL certiflcatlon 10-11-12.pdf
Impact Resistant:N/A Quality Assurance Contract Expiration Date
Design Pressure:N/A 10/10/2015
Other:Asphalt shingles shall be used only on Installation Instructions
roof slopes of-2:12'or greater.Nails must be used. FL1956.R8 II heritage prem app Jnst.odf
as the method of attachment. FL1956 R8 H heritage prem app Inst frederick pdf
Verified By:Robert Nleminen 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.7 Heritage Woodgate A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use In HVHZ:No 'FL1956 R8 C CAC Tamko SerV Conf FL 1956 2012 odf
Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certiflcatlon 10-11-12 pdf
Impact Resistant:N/A Quality Assurance Contract Expiration Date
Design Pressure:N/A 10/10/2015
Other:Asphalt shingles shall be used only on Installation Instructions
roof slopes of 2:12 or greater.Nalls.must be used FL1956 R8 II Woodgate app Inst D Oct it odf
as the method of attachment. FL1956 R8 11 Woodgate app Inst F Oct 11 pdf
Verified By:Robert Nleminen 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956.8 Heritage XL A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012 odf
Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certlflcation 10-11-12 pdf
Impact Resistant:N/A Quality Assurance Contract Expiration Date
Design Pressure:N/A 10/10/2015
Other:Asphalt shingles shall be used only on Installation Instructions
roof slopes of 2:12 or greater.Nails must be used FL1956-118'II heritage A app Inst d april 10 pdf
as the method of attachment. FL-1956 R8 H heritage xl app Inst f april 10 pdf.
Verifled By: Robert Nieminen PE 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
1956'.9" Hip and Ridge Shingles Hip and ridge shingles
Limits of Use 'Certification Agency Certificate
Approved for use in HVHZ:No FL1956 RB C CAC Tamko Seri Conf FL 1956 2012 pdf
Approved for use outside HVHZ:Yes . FL1956 R8 C CAC UL certification 10-11-12 pdf
Impact.Resistant:N/A Quality Assurance Contract Expiration Date
Design Pressure:N/A 10/10/2015
Other:Hip and Ridge shingles shall be used only Installation Instructions
on roof slopes of 2:12 or greater. Nails must be FL1956 R8 R 1225 x 12 Hip Ridge Application Instructions pdf
used as the method of attachment. FL1956 RB II 12 x 12 HIP Ridge Application Instructions.pd
FL1956 R8 II i2-1-4x12 HioRidae Sealant Dab Illustrations.pd
FL1956 R8•R 12x12 HipRidge Sealant Dab Illustrations pdf
Verified By: Robert Nieminen 59166
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
Ba.k .Next .
3'of 4 11/7/2013 8:49 AM
CA
October 11,2012
Tamko Building Products Inc
Ms.Kerri Eden
220 W 4th St
PO Box 1404
Joplin,MO 64801
RE: TAMKO Shingles
Dear Ms.Eden:
This is to confirm that the attached shingle matrix pertains to Tamko produced shingles.
All the products have.been tested and meet the criteria for the standards mentioned. They are covered by
UL's Follow-Up Service Program under Tamko's File R2919.
The Listing Mark of Underwriters Laboratories Inc.on the product is the only method provided by UL to
identify products manufactured under its Listing and Follow-Up Service.
Combination Listing/Classification Mark—A Listing Mark combined with a Classification Mark is
provided on products that have additionally been investigated in accordance with various supplemental
standards. Please refer to the labels on the product.
Should you have any questions,please feel free to contact the writer.
Very truly yours, Reviewed By:
William G Marshall(Ext.42735) Alpesh Patel (Ext.42522)
Sr.Engineering Associate Staff Engineer
Fire Protection Division 3019A Fire Protection Division 3019A
TAMKO Shingle Citrix
Phillipsburg, M Frederick, IM
PMOdUCt boas AM ASM AM HL ASTM CBA Product Halm ASTM ASTM ASTM UL MM CBA
D3462 D2161 B6281 2399 D7158 123.5 D3462 W161 D6281 239D D7158 123..5
Class Mass Class Class Mass C3:255 Class Klass
F H H H F H H H
Glass-Beal (AR} Glass-Beal {AR) X x H x x
Elite class-Beal (ARI Elite Giass-Seal. (AR) x x x x x
Heritage x x x x x x Heritage x x x x x x
Heritage 20 (AR} x x x x x x Heritage W (AR} x x x K x x
Heritage KL (AR) Heritage XL (AR} x x - - -
Heritage W004ate K x - - -
Heritage so (AR) x x x x x x Heritage 50 (ARI x x x x x K
Heritage PSe=UU - x x x x x x Heritage Premium x x x x x x
Heritage Wntage (AR} x x x x x x Heritage Vintage (AR)
Heritage Nottage K A ---- ---- ---- 12-1/4 x 12 Hip and Ridge K x
12 x 12 Hip and Ridge
Dallas, TK Tuscaloosa, AL
Product N mm ABTH ABTA AM UI AM CBA HL product Kim ASTM AM A9TK UL AgTH CBA
D2462 D2161 D6281 2388 D7158 1231.5 2215 D2462 D2161 D6381 2290 D7158 122.5
Class Class Class Class Class Class Class Class
F H H H F H H H
Glass-Beal (AR} Glass-Beal, (AR) x x x x x
Elite +glass-Beal (AR) Elite Glass-Beal (3R) x x x x x
Heritage x x x x x x Heritage x x x x x x
Heritage 28 (ARI x x x x x x Heritage 28 (AR) x x x x x x
Heritage XL (AR( x K x x x Heritage XL (AR)
Heritage !Soodgate x x x x x x
Heritage 50 (AR)' x x x x x x Heritage 5o (ARI x x x x x x
Heritage :psemium x x x x x x Heritage Premium x x x x x x
Heritage Vintage (AR} Heritage "vintage (AR)
Heritage FR is x x K x x i' 12 x 12 Hip and Ridge x x ---
Japl in, M
Product Name ASM D3462 ASM D3161 ASTM 06391 HIL 2390 ASM x]7153 CSA
Class F Class H Class H Class H 123.5
Glass-Seal (AR) x - x x x
Elite Glass-Seal (AR) x x x x x
Heritage x x x x x x
Heritage 30 (AR) x x x x x x
Heritage XL (AR)
Heritage 50 (AR)
Heritage Premium
Heritage Vintage (P13)
12 x 12 Hip and Ridge x x ---- -�- �-
12-1/4 x12 Hip Ridge" x x
October 10,2012
Tamko Building Products
220 W 4th Street
PO Box 1404
Joplin, MO 64801
Contact Name: Kerri Eden
Email Address: Kerri Eden@tamko.com
Subject: UL Third Party Inspection Service for Florida Quality Assurance
Expiration Date: October 10, 2015
Reference: File R2919
Dear Ms. Eden:
This letter is to confirm that Tamko Building Products has an agreement with UL LLC to conduct
audits at your plant to verify Florida Quality Control requirements at the following locations:
Tamko Building Products Tamko Building Products Tamko Building Products
601 N.High St 1598 Hwy 183 2300 351h St
Joplin MO 64801 Phillipsburg KS 67661 Tuscaloosa AL. 35401
Tamko Building Products Tamko Building Products
7910 S Central Expy 4500 Tamko Dr
Dallas TX 75216 Frederick MD 21704
Quality Control System and Products will be inspected according to Florida Product Approval Report
FL1956 to ensure the manufacturer's quality documentation is well defined,fully documented and
effectively implemented.
A minimum of two(2)inspections per year will be conducted. This service has been established
under file R2919.
UL LLC
333 Pfingsten Road,Northbrook,IL 60062-2096 USA
T.847.272.8800/F:847.272.8129/W:U L.Com
If you have any questions, please call me at 314-578-3406.
Kind regards,
� 'M
J.Kay Chancellor
Project Coordinator
Product Safety
UL LLC
333 Pfingsten Road
Northbrook, IL 60062-2096 USA
M:314-578-3406
F: 847-664-6157
W ul.com
® Application instructions for FORMERLY HERITAGE®30
ElKO HERmAror
BU16DII10 PRODUCTS LAMINATED ASPHALT SRIN066S
Tuscaloosa,AL
THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM
FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY
AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.
IMPORTANT FASTENING INFORMATION:DO NOT PLACE FASTENERS ON OR ABOVE THE PAINT LINE ON THE SHINGLE.The paint
line on the shingle is the upper-most edge of TAMKO's expanded Nail Zone. For complete details regarding TAMKO's expanded Nail
Zone,see section 3 of these Application Instructions. Failure to follow fastening instructions,including but not limited to improper
placement of fasteners on or above the paint line,will adversely affect coverage under TAMKO's applicable Limited Warranty.Avoid
placing fasteners into the sealant strip.
IMPORTANT It Is not necessary to remove the plastic strip from the back of the shingles.
1.ROOF DECK area per 300 square feet if at least 40%and not more than 50%
These shingles are for application to roof decks consisting of of venting is provided not more than 3 feet below the ridge or if a
plywood or sheathing boards capable of receiving and retaining Class I or II vapor barrier is Installed on the warm in winter side of
fasteners,and to Inclines of not less than 2 in.per foot.For roofs the ceiling In climate zones 6, 7, and 8 as recommended by the
having pitches 2 in. per foot to less than 4 in. per foot, refer to 2012 International Residential Code.For more information consult
special instructions titled"Low Slope Application".For roofs having your design professional.If the ventilation openings are screened,
pitches greater than 21 in.per foot,refer to special Instructions titled the total area should be doubled.
"Mansard Roof or Steep Slope Roof'. Shingles must be applied IT IS PARTICULARLY IMPORTANT TO PROVIDE
properly.TAMKO assumes no responsibility for leaks or defects ADEQUATE VENTILATION.
resulting from improper application,or failure to properly prepare
the surface to be roofed over.. $.FASTENERS
NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, WIND CAUTION: Extreme wind velocities can damage these
dry and free from warped surfaces.It is recommended that metal shingles after application when proper sealing of the shingles does
drip edges be installed at eaves and rakes. not occur. This can especially be a problem if the shingles are
PLYWOOD:All plywood shall be exterior grade as defined by applied in cooler months or in areas on the roof that do not receive
APA-The Engineered Wood Association. Plywood shall be a direct sunlight.These conditions may impede the sealing of the
minimum of 3/8 in.thickness and applied in accordance with the adhesive strips on the shingles.The Inability to seal down may be
recommendations of APA-The Engineered Wood Association. compounded by prolonged cold weather conditions and/or blowing
SHEATHING BOARDS Boards shall be well-seasoned tongue- dust.In these situations,hand sealing of the shingles is required.T®
insure immediate sealing,apply 4 quarter-sized dabs of TAM-PRO
and-groove boards and not over 6 in.nominal width.Boards shall Premium SBS Adhesive orTAMKO Tam-Seal Adhesive on the back of
be a 1 in. nominal minimum thickness. Boards shall be properly the shingle 1 in.(25mm)and 13 in.(330mm)In from each side and 1
spaced and nailed. in.(25mm)up from the bottom of the shingle.Press shingle firmly into
2.VENTILATION the adhesive.For maximum wind resistance along rakes,install any
TAMKO starter shingle Including sealant or cement shingles to the
Inadequate ventilation of attic spaces can cause accumulation of underlayment and each other in a 4 in.(102mm)width of TAM-PRO
moisture in winter months and a build up of heat in the summer. SBSAdhesiveorTAMKOTam-SealAdhesive.Caution:ApplyONLYa
These conditions can lead to: thin uniform layer of adhesive less than 1/8 in.(3mm)thick Excessive
1.Vapor Condensation amounts can cause blistering of the shingles and may soften the
asphalt in certain underlayments resulting in the asphalt flowing,
2.Buckling of shingles due to deck movement. dripping and staining.Shingles must also be fastened according to
3.Rotting of wood members. the fastening instructions described below.
4.Premature failure of roof. Correct placement of the fasteners is critical to the performance of
the shingle.If the fasteners are not placed as shown in the diagram
To Insure adequate ventilation and circulation of air,the ventilation and described below,this will result in the termination of TAMKO's
system must include inlets and outlets.This may be accomplished liabilities under the Limited Warranty.TAMKO will not be responsible
with a combination of ridge and soffit vents or by using gable end fordamage to shingles caused by winds in excess of the applicable
vents.FHA minimum property standards require one square foot mph as stated in the Limited Warranty.See Limited Warranty on the
of net free ventilation area to each 150 square feet of space to wrapper or tamko.com for details.
be vented.This may be reduced to one square foot of ventilation (Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 05/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
-- Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 1
® (CONTINUED from page 1) FORMERLY HERITAGE°30
TAMKO HERinno
89160ING PRODUCTS LAMINATED ASPNA6T SHING6ES
Tuscaloosa,AL
FASTENING PATTERNS: 4) High Wind Fastening Pattern. (For High Wind Application
1) NAIL ZONE: The Nail Zone for standard fastening is defined as requirements)One fastener 1 in.from each end.One fastener 8-1/2
the 1-3/4 in.area beginning at 6-1/8 in.from the bottom edge of in.from each end and one fastener 16 in.from each end for a total
the shingle and ending at the paint line located at 7-7/8 In.from the of six(6)fasteners per shingle.In addition to this shingle fastening
bottom edge of the shingle. DO NOT PLACE FASTENERS ON OR pattern requirement for High Wind Application,TAMKO also requires
ABOVE THE PAINT LINE ON THE SHINGLE. the use of TAMKO starter shingles including sealant strip at eaves and.
rakes.Alternatively,along rakes,cement shingles to the underiayment
2)Standard Fastening Pattern Options. and each other in a 4 in.(102 mm)width of TAM-PRO SBS Adhesive
(For use on decks with slopes 2 in.per foot to 21 in.per foot.) or TAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin uniform
layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts can
A.Preferred Fastener Location:Fasteners should be placed 6-1/8 cause blistering of the shingles and may soften the asphalt in certain
In.from the bottom edge of the shingle, penetrating through the underlayments resulting in the asphalt flowing,dripping and staining.
common bond,and located horizontally as shown In the Standard High Wind Application Is offered on new construction or complete
Fastening Pattern diagram. tear-off applications only.It is not offered for recover applications.If
High Wind Application requirements are not followed,the High Wind
B. Acceptable Fastener Location:Fasteners must be placed in Application Warranty MPH,as stated on Table I in the Limited Warranty,
the 1-3/4 In.nailing area beginning at 6-1/8 In.from the bottom edge reverts to the Standard Application Wind Warranty MPH limit.(See
of the shingle and ending at the paint line located at 7-7/8 In.from Mansard and High Wind Fastening Pattern illustrated above.)
the bottom edge of the shingle. Nails shall be located horizontally CAUTION: ALL FASTENERS FOR MANSARD AND HIGH WIND
as shown in the Standard Fastening Pattern diagram. APPLICATIONS MUST BE DRIVEN INTO THE NAIL ZONE
CAUTION:Fasteners must not be driven into the edge of the COMMON BOND(PREFERRED FASTENER LOCATIONS)AS SHOWN
common bond area.Avoid placing fasteners into the sealant strip. IN THE MANSARD AND HIGH WIND FASTENING PATTERN DIAGRAM.
STANDARD FASTENING PATTERN IN NAIL ZONE NAILS:TAMKO recommends the use of nails as the preferred method
of application. Standard type roofing nails should be used. Nail
12-1/2"—*f*—12-WS-—+— 12-1/2"—.�I.-1" shanks should be made of minimum 12 gauge wire,and a minimum
PAINT PREFERRED FASTENER LOCATIONS Properly Driven Improperly odven
LIN3B°min diameter underdrlven avwdrlven tweaked
7-7/8" _. _ _ NAIL ZONE ...._Aephait
._..�_. .....�..�. _.._. ._._. .. - Shingles
6-1/8" EDGE OF Et �� —Decking
BOND ON a+l
1/4'neminal
EXPOSURE straight,good penetration, Inadequate too deep,outs Inadequate
5-5/e" and flush with shingle surface penetration Into Mingte anchorage
ACCEPTABLE
FASTENER LOCATION head diameter of 3/81n.Nails should be long enough to penetrate
ALONG EDGE of 3/4 in.Into the roof deck.Where the deck is less than 3/4 in.thick,
_. COMMON BOND the nails should be long enough to penetrate completely through
PREFERRED plywood decking and extend at least 1/8 In.through the roof deck.
FASTENER Drive nail head flush with the shingle surface.
LOCATION
STAPLES:If staples are used in the attaching process,follow the
3 Mansard Fastening Pattern. above Instructions for placement.All staples must be driven with
g (For use on decks with slopes pneumatic staplers.The staple must meet the following minimum
greater than 21 in.per foot.)One fastener 1 in.from each end and dimensional requirements.Staples must be made from a minimum
one fastener 8-1/2 in.from each end and one fastener 16 in.from 16 gauge galvanized wire.Crown width must be at least 15/16 in.
each end for a total of 6 fasteners per shingle.(See Mansard and (staple crown width Is measured outside the legs).Leg length should
High Wind Fastening Pattern illustrated below.) be a minimum of 1-1/4 in.for new construction and 1-1/2 in.for
reroofing thus allowing a minimum deck penetration of 3/4 in.The
FASTENERS NAIL ZONE crown of the staple must be parallel to the length of the shingle.
BOND ON The staple crown should be driven flush with the shingle surface.
Staples that are crooked,underdriven or overdriven are considered
8 EXPOSURE 55/8" improperly applied.
'[1Properly Driven Improperly Driven
1 �7-1/2'+ -7-V2"air 7 3I8"►�r7-12 -7-12"►I �1" BSN underdriven oveninven crooked
MANSARD AND HIGH WIND FASTENING PATTERN ^ShIneles
�---Detddng
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 05/14
Visit Our Web Site at Northeast District 4500 Tamko.Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 A
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 G
® (CONTINUED from page 2)
FORMERLY HERITAGE®30
TAMKO RRRITAGES
BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES
Tuscaloosa,AL
4.UNDERLAYMENT S.APPLICATION INSTRUCTIONS
UNDERLAYMENT An underlayment must be applied over the STARTER COURSE:A starter course may consist of TAMKO Shingle
entire deck before the installation of TAMKO shingles.Failure to add Starter,TAMKO 10-inch Starter or self-sealing 3-tab shingles.If self-
underlayment can cause premature failure of the shingles which is sealing 3-tab shingles are used,remove the exposed tab portion and
not covered by TAMKO's Limited Warranty. install with the factoryapplied adhesive adjacent to the eaves.Attach
Products which are acceptable for use as underlayment are: the starter course with approved fasteners along a line parallel to
and 1.5 in.to 3 in.above the eaves edge.The starter course should
Asphalt Saturated Felt Underlayments• overhang both the eaves and rake edges 1/4 in.to 3/8 in.if drip edge
• TAMKO SuperX 15TM or SuperX 30TM Underlayment flashing is not used along the eaves or rakes.if drip edge flashing
• TAMKO No.15 Asphalt Saturated Organic Felt is present,install shingles even with the drip edge.
For And
• An TAMKO non-perforated asphalt saturated organic felt TAMKO smm'WMIS Is do sealant or rhe en�'
Y P P rg TAMKO ahhglaa
to*PROyment ee each o0wrin a T(102 mm)pool of
• A non-perforated asphalt saturated organic felt which meets
TA*PRO AdhasNe undadeyment pea Eawflawhem
ASTM:D226,Type I or II or ASTM D4869 asphalt saturated fall
Specialty Underlayments:
• Tam-Shield®Synthetic Underlayment as �.
e ..............................................
• TAMKO Moisture Guard Plus®, TW Underlayment and TW Reye �.
Metal and Tile Underla ment® additional ventilation may be I—Irld 1- _
Y ( Y from roe'ase s------ --- "
required.ContactTAMKO's Technical Services Department for
more information.)
• Aself-adhesive underlayment designed for use with asphalt SttBraa,Pr,,m,aahIV. slar,ershipsmhang Sae.aaarne � Fasteners ori;ea,e
shingles which meets ASTM D1970. rernowd.Nen foil Mh fell eavesendrones aenasNa toted
WPs In older N eDset v�dh Ina 1!4•toafa'erroddp edge posMoned 1-12 to a,
grat ahhgle mums. Dashing Is posted.If ddp along eaves ham save edge
For Asphalt Saturated Felt Underlayments• ge aswe enmkaedge
Apply the felt when the deck is dry.On roof decks with slopes MP edge.
4 in. per foot and greater apply the felt parallel to the eaves SHINGLE APPLICATION:Start the first course with a full size shingle
lapping each course of the felt over the lower course at least and overhang the rake edge 1/4 in.if drip edge is not present. If
2 in.Where ends join,lap the felt 4 in.If left exposed,the felt drip edge is present,align shingle edge with drip edge flashing.Cut
may be adversely affected by moisture and weathering.Laying 10-3/8 in.from a full shingle to form a shingle 29 in.long.Use this
of the felt and the shingle application must be done together, to start the second course(see diagram below).Cut a 23 in.long
For All Other Specialty Underlayments• shingle to start the third course.Use the remaining 16-3/8 in.piece
of shingle to start the fourth course and use the remaining 10-3/8
On roof decks with slopes 4 in. per foot and greater apply in.piece to begin the fifth course.Continue up the rake in as many
the underlayment parallel to the eaves in accordance rows as necessary using the same formula as outlined above.
with underlayment written application instructions. The
underlayment should not be left exposed for a longer period of
time than is specified in the underlayment's written application
instructions.The final roof covering must be installed before
the structure is exposed to adverse weather conditions,such 10-318'
as wind driven rain,high wind,hail,ice storms,etc.
In areas where ice builds up along the eaves or a back-up of water crepe
s
from frozen or clogged gutters is a potential problem, TAMKO's '
Moisture Guard.Plus®,TW Metal and Tile Underlayment or TW z3e
Underlayment(or any specialty eaves flashing product) may be
applied to eaves,rakes,ridges,valleys,around chimneys,skylights
or dormers to help prevent water damage. Contact TAMKO's Wako `si
Technical Services Department for more information. IW/8'
Substitute products as shingle underlayment should not be used. sin sparse
4th course
3rd course "
a '
2nd course
lstcourse
eave-�
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 06/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.Com Southwest District 7910 S.Central Ldp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3
® (CONTINUED from page 3) FORMERLY HERITAGE®30
TAMKO HEWTAwo
OU16DING PRODUCTS 6AMINATED ASPHA6T SHING6ES
Tuscaloosa,AL
The butt of the shingle should be aligned with the top edge of the mufti-layered shingles.The performance of the sealant feature may
sawtooth of the underlying shingle for a 5-5/8 in. exposure(see be compromised,preventing the shingles from sealing properly.It is
shingle application drawing Illustrated on this panel). When you acceptable to install laminated shingles over existing three-tab strip
make your final cut at the roof's edge,flip any pieces that are 8 in.or shingles which are flat and essentially intact.Nail down or remove curled
longer back onto the roof.These pieces can be worked in anywhere or broken shingles from the existing roof.Replace all missing shingles
without creating zippers or color variations. with new ones to provide a smooth base.Shingles that are buckled
NOTE:Do not align joints of shingle courses when working in cut usually indicate warped decking or protruding nails.Hammer down all
pieces.Joints should be no closer than 4 in.from one another. protruding nails or remove them and refasten in a new location.Remove
all drip edge metal and replace with new.
1L Cut your first course shingle to make 2W and a 10318' If re-roofing over an existing roof where new flashing is required to
leng8s Wb t a second shingle make a 23'and protect against ice dams(freeze/thaw cycle of water and/or the backup
a la 7/a'length.
10�• �" of water in frozen or clogged utters remove the old roofing to a point
ze' � 99 gutters), 9
rr _ at least 24 in.beyond the interior wall line and applyTAMKO's Moisture
Guard Plus®,TW Metal and Tile Underlayment,or TW Underlayment.
I
Contact TAMKO's Technical Services Department for more Information.
Measurements will vary when nesting over an existing 5 in.exposure
single roof:Call TAMKO Technical Services for further information.
The nesting procedure described below is the preferred method for
reroofing over existing metric size shingles with a 5-5/8 in.exposure.
See description below:
2ThgNappgraft.WthaNOlength dingle. Starter Course:Remove the tabs and an additional portion from the
Jay
your 28',23,18 318'and 10 318'lengths.
As you can No,three ehlogles with n..ala head of a full size shingle so that its height is equal to the exposure of
maker"eeearses. the existing shingles.Position the resulting strip over the existing roof
Cominue working ykwway across the root.When you make your edge(with the factory-applied adhesive strip along the eaves).Cut
3.rmaiatatthemnraedge,glp ypiecesthatare8'erlonger approximately 6 in.from the rake end and apply the remaining portion at
back onto tha root.These pieces can be worked In anywhere without the eaves.Continue the starter strip by applying full length shingle strips
ceagng rippers or odor miallons.
NOTE Do not soon Joint.of shingle...aswban woddng In cut to height as above,evenly along the existing roof at the eaves.The
cul pletts.,lolato should be no closer thin 4'from ono another
existing roof should overhang the eaves far enough to carry water
off into the gutter.If this is not the case,cut and apply the starter
6.60W SLOPE APPbMATION strip so that it will provide sufficient overhang for proper drainage.
On pitches 2 in.per foot to 4 In.per foot cover the deck with two First Course:Remove an amount from the butt edge of afull-size shingle
layers of underlayment. Begin by applying the underlayment in a so that the remaining portion of the shingle fits between the butts of the
1/2-sheet width along the eaves and overhanging the drip edge existing third course.This course must also be applied evenly along the
by 1/4 to 3/4 in.Place a full-sheet width over the 1/2-sheet width eaves edge of the new starter strip.
starter piece,completely overlapping it.All succeeding courses will
be positioned to overlap the preceding course by 1/2-sheet width. Exisfing Shingles
If winter temperatures average 25eF or less, thoroughly cement
the laps of the entire underlayment to each other with TAM-PRO 5 °•�
or TAMKO Plastic Roof Cement from eaves and rakes to a point 131/4 k
of a least 24 in.inside the interior wall line of the building.As an
alternative,TAMKO's Moisture Guard Plus®, TW Metal and Tile '
Underlayment, or TW Underlayment self-adhering underlayment _
may be used in lieu of the cemented felts. Drip edge z
Drip edge
9.MANSARD ROOF OR STEEP SLOPE ROOF New shingles _x '
If the slope exceeds 21 in. per foot (601, each shingle must be
sealed with TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive 5 5/8° 5 5/8'exposure
immediately upon installation.Quarter-sized dabs of cement must exposure
be applied to shingles with a 5-5/8 in.exposure,use 6 fasteners per
shingle.See Section 3 for the Mansard Fastening Pattern.
Second and Succeeding Courses:Remove 10-3/8 in.from the rake
8.BE-ROOFING end of the first shingle in the second course,and continue with full
width shingles for the remainder of the course,placing the top edge of
Before re-roofing,be certain to inspect the roof decks.All plywood shall each new shingle against the butt edge of the old shingle In the course
meet the requirements listed in Section 1. above.This method should create an exposure of 5-5/8 in.afterthe first
It is not recommended to install laminated asphalt shingles directly course.When beginning the succeeding courses continue to follow the
over existing laminated shingles due to the unevenness of the existing Heritage application instructions.(See section 5).
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 05/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamkoxom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 A
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4
® (CONTINUED from page 4) FORMERLY HERITAGE®30
TAMKO HERITAGE®
BUILDING PRODUCTS LAMINATED.ASPHA6T SHING6CS
Tuscaloosa,AL
9.VALLEY APPLICATION 10.RIP AND RIDGE FASTENING DETAIL
Over the shingle underlayment,center a minimum 36 In.wide sheet Apply the shingles with a 5-1/8 In.exposure beginning at the bottom
of TAMKO Moisture Guard Plus®,TW Metal&Tile Underlayment, of the hip or from the end of the ridge opposite the direction of the
or a minimum 50 Ib.roll roofing in the valley.Nail the underlayment prevailing winds.Secure each shingle with one fastener on each side,
only where necessary to hold it in place and then only nail the 5-5/8 in.back from the exposed end and 1 in.up from the edge.
outside edges. TAMK0 recommends the use of TAMKO Hip & Ridge shingle
IMPORTANT:PRIOR TO INSTALLATION,WARM SHINGLES TO products.Where matching colors are available,it is acceptable to
PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces.
SHINGLES TO FORM VALLEY. The length of the fastener should be long enough to penetrate
After valley flashing is in place: through the roofing material and 3/4 In,into the wood decking or
• .Apply the first course of shingles along the eaves of one of the completely through approved plywood.
intersecting roof planes and across the valley. IMPORTANT PRIOR TO INSTALLATION, CARE NEEDS TO BE
Note:For properflow of water over the trimmed shingle,always TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
start applying the shingles on the roof plane that has the lower BENDING SHINGLE IN COLD WEATHER.
slope or less height. Direction of prevailing wind
• Extend the end shingle at least 12 in.onto the adjoining roof. start 5-1/8"exposure
Apply succeeding courses in the same manner,extending them here- H x,18, 1"
across the valley and onto the adjoining roof.
� Fastener
• Press the shingles tightly into the valley. Ill ISS 5/a"
• Use normal shingle fastening methods. here "
5-1/8 exposure
Note:No fastener should be withint In.of the valley centedine, THESE ARE THE MANUFACTURER'S APPLICATION
and two fasteners should be placed at the end of each shingle INSTRUCTIONS FOR THE ROOFING CONDITIONS
crossing the valley. DESCRIBED.TAMKO BUILDING PRODUCTS,INC.ASSUMES
• To the adjoining roof plane,apply one row of shingles vertically NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
facing the valley and 2 in.back from the valley centerline. DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW
Note: For a neater installation, snap a chalkline over the THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE'
shingles for guidance. UNDER THE LIMITED WARRANTY. SEE THE LIMITED
• To complete the valley, apply shingles on the adjoining roof WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS
plane by positioning the tip of the first shingle of each row at REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE
the 2 in.point from the centerline where the edge of the vertical CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
shingle has been applied,covering the vertical shingle. 800-641-4691.
Valley centerline
Minimum 3fi°wide sheet
of Moisture Guard Plus j Information included in these application Instructions was current at time of priming.To
TW Metal&Tile Extra nail in obtain a copy of the most current version of these application instructions,visit us online
or 50 Ib.or ,., end of shingle at tamko.com or call us at 800-641-4691.
heavier roll roofing , -. Extend end shingle
12'-18'beyond
.'; valley centerline
�S TAMKO®,Moisture Guard Plus®,Tam-Shield®,TAxt-PRO®and Heritage®are registered
trademarks and SuperX 15 and SuperX 30 aretrademarks of TAMKO Building Products,Inc.
Undedayment No fasteners within
6'of centerline
Place tip of shingle on the edge of
the vert(atshingle,2 inches back
firm valley cente�ne and covering
the vertical shingle.
FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
800-641-4691.
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 05/14
Visit our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 G
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 5
Florida Building Code Online http://www.floridabuilding.oig/pr/pr�_app_4tl.aspx?param=wGEVX
• r.
7�od ppammtd BC15 Home Log In User Registration i Hot Topirs SubmR Surcharge ; Stats&Facts Publications FBCStaff BCIS Site Map t Links Search
Busines •
Professi I Product Approval
r JJ USER:Public User
Regulation :
Product Aonroyal Menu>Product or Application Search>ApoBcation List>AppEratioo Metall -
FL# FZ 664"--k
Application Type Affirmation
Code Version -2Qi?0 �
Application Status Approved
Comments '
Archived 2-1
Product Manufacturer c�TAMIC018nItding P,io GtsInc.
Address/Phone/Email PO Box 1404 v
Joplin,MO 64802
(417)624-6644 Ext 2305
kerrl–eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden @tamko:com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerrL-eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Test Report
Testing Lab PRI Construction Materials Technologies,LLC-
Quality
LCQuality Assurance Entity Underwriters Laboratories Inc.
Quality Assurance Contract Expiration Date. 03/26/2013
Validated By RobertJ.M.Nieminen,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL3664 R5 COI PRI CMT Cert of Independence gdf
Referenced Standard and Year(of Standard) SSandard Year
ASTM D 1970 2001
cla�
a roduct Standards
MJI affirm that there are no changes in the new Florida Building
Code which affect my product(s)and my product(s)are in
compliance with the new Florida Building Code.
1 of 2 3/2/2015 9:54 AM
j
Florida Building Code Online http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVX...
Documentation from approved Evaluation or Validation Entity .::,Yes ; No rtti'N/A
Product Approval Method Method 1 Option B
Date Submitted 10/12/2011
Date Validated 10/12/2011
Date Pending FBC Approval
Date Approved 10/20/2011
Date Revised 03/04/2013
Summary of Products
FL# Model,Number or Name Description
3664.1. �.�-cl�IV�lllfdj�rlay nt�,�3 A self-adhering rubberized asphalt sheet membrane.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL3664 RS II tw underlayment apo Ins.Ddf
Approved for use outside HVHZ:Yes Verified By:ICC Evaluation Service,LLC
Impact Resistant:N/A Test Reports
Design Pressure:N/A FL3664 R5 TR PRI TW Underlavment.Ddf
Other:Membrane should not be applied to damp,frosty or
contaminated surfaces.Membrane should not come-Into
contact with products containing coal-tar pitch.Not approved
for use In'High Velocity Hurricane Zones.
Bade Next
Contact Us;;1940 North Monroe Street Tallahassee Fl 37399 Phone-89n-4A7-1A24
The State of Florida Is an AAJEEO'employel.Cnpyr(ght 2007-2013 State of Florida::;PnUary Statement;:Ayre,ssibihty Statement::Refund Sta m nt
., Under Florida law,email addresses are public records.If you do not want your e-mall address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional maL If you have any questions,please contact 850.487.1395.-Pursuant to Section .
455275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an emag address if they have
one.The emalls provided may be used for official communication with the licensee However email addresses are public record.If you do not wish to supply a
.' personal address,please provide the Department with an email address which can be made available to the public.To determine 8 you are a licensee under Chapter
455,F.S.,please click ben.
Product Approval Accepts:,. -
® it'AC
2 of 2 3/2/2015 9:54 AM.
c
< r
CONSTRUCTION MATERIALS
TECHNOLOGIES
CCUI)rrE
LABORATORY TEST REPORT
Report for: Tamko Building Products,Inc. Date: November 8,2007
224 W.4th Street
Joplin,MO 64802
Attention: Aaron Phillips
Product Name: TW Underlayment Manufacturer: Tamko Building Products
Date Received: October 17,2007 Source: Tamko Building products
PRI Project No.:' TAP-193-02-01 Metro Dade Notification No.: PR107224
Subject: The purpose of this project was to determine performance properties of Tamko TW
Underlayment for compliance with the requirements of ASTM D 1970-01, Standard
Specification for Self-Adhering Polymer Madfied Bituminous Sheet Materials Used as Steep
Roofing Underlayment for Ice Dam Protecdon.
Test Methods: The test methods used included those found in ASTM 1970:Standard Spec�f'rcafion for Self-
Adhering PolymerModrlted Bituminous Sheet Materials Usedes Steep Ranfrng Underfeyment
forlce Dam Protection or referenced in ASTM D 1970 including: ASTM D 228:TestMethods
for Asphalt Roll Roofing, Cap Sheets,and Shingles,ASTM D 903: Test Method for Peel or
Stripping Strength of Adhesive Bonds,ASTM D 1204: Test Method.fcr Linear Dimensional
Changes of Nonrigid Themloplas6c Sheeting or Film at Elevated Temperature,ASTM D
2523:Practice for Testing Load aMin Properties of Roofing Membranes,ASTM D 4073:Test
Method for Tensile-Tear Strength of Bituminous Roofing Membranes,ASTM D 5147: Test
Methods for Sampling and Testing A4lodrfred Bituminous Sheet Material and ASTM E 96:Test
Methods far Water Vapor Transmission of Materiels,ASTM D 4521:Standard TestMethod for
Coefficient of Static Friction of Corrugated and Solid Fiberboard.
Product A full factory labeled roll of TW Metal and Tile Underlayment was supplied byTamko Building
Sampling: Products.
TAP-193-02-01 PRI Accreditatons:IAS-ES TL-189•State of Florida TST 5878!Metro-Dade 06.1118.02;CRRC
The test results,opinions,or Interpretations are based on the rrraterial supplied bythe dent. This report is for the exclusive use of stated
client No reproduction or faesinle in any form can be madewlNuAthe clienfa permission.Thisreport"not be reproduced except m full
withoutthewril6en approval of this laboratory. PRI Asphalt Techm Ries,Inc.assumes no respowbi itynor makesa pertarmanosorwmranty
statement for this material or products and prooesses containing this material in connection with this report.
PRI Gwwk=tkn Materials Tattrph9%s,LLr+6408 Badger Dft Tampa.FL 33610 Tet BI M5M Fan 8136215840 emf mm Wa6Sft WAw ViR#Q1Lmm
Tamko Building Products
Laboratory TOM Report for TW Underiaymer t
PRI07224
Page 2 of 3
Results of Testin
Property ASTM Test Method Result 1 ReClUirement
ThiEER=,mils D 5147 43 40 mint
Maximum load at break @ 73A±3.6°F,lbffin
Longitudinal D 2523/D 1970 28.1 25 min
Transverse 28.7 23 min
Maximum elongation at break @ 73A:t 3.6°F,°A
Longitudinal D 2523 30.0 10 min
Transverse 17.2 10 min
Adhesion to plywood @ 75±2°F;Ibf/ft D 903/D 1970 56.7 12 min
Adhesion to plywood @ 40±2°F,Milt D 903/D 1970 73.3 2.0 min
Thermal Stability,in D 1204/D 1970 0.0 0.1 max
Low Temp Flex at-20°F,Pass/Fall D 1970 Pass No cracking
Waterproof integrity,Pass/Fail D 1970!7.9 Pass No water
Tear Resistance,lbf
Longitudinal D 4073/D 1970 48.3 20 min
Transverse 41.7 20 min
Moisture Vapor Permeability,U.S.Perms E 96 Inv.Water(BUI) 0.04 0.1 max
Self-Sealabildy,Pass/Fail D 1970 Pass No water
Waterproof integrity of lap seam, D 1970 Pass No water
Pass/Fall
Slip Resistance @73°F,(Inclined Plane coefficient D 4521 0.78 a No.15 Organic
of static friction) felt>_0.78
Unrolling @ 40 and 140°F,Pass/Fall D 1970 Pass No damage
Statement of Compliance:
The product tested complies with all of the requirements of ASTM D 1970: Standard Spm*cafron for Seff-
Adhenng Polymer M minorts Sheet Materials Used as Steep Roofing Underlayment for foe Dam
Protection.
Signed:
ebOry Technn
Date:
e
Signed: y Signed:
Donaw isDUVT.Won
Priasident Rortda ReWmferidArefesstonal Engineer
�7 PE No.:0034
Date: � / Date: All&'2-8h3
TAP-193-02-01 PRI AcmWt tions:IAS-ES TL-189 State of Rodda TST 5878:Metro-Dade 06.1418.02;CRRC
The test results,opkdons,or irrterprsUWM are based en the naterial supplied by the client. ThIs report is for the exctcshre use of stated
cilea tufo reproduction orfacsimile in arryfoim can be rade without the ctienfe pemnssion.This report shall r4be reproduced w=ptin fuf
wittmut the written approval of this laboratory. PRI Asphalt TechnoWes,Inc.assumes no responaibifdy nor rekesaperforrnanceorwana*
statement for this material or products and processes containing this material in eonnectlon with ties report.
PRI uddn MaWal;TedMb&S,LLC.6408 Badger Dins Tanpe,FL 33610 Tet 8135215TT7 Fac 8135215840 e•m28 mateftkWdh2@*mt Ccm WetSSe:htlpJJwwx.pme*atcem