Loading...
HomeMy WebLinkAboutDrawing Opening Size . (WxH) 1.'FL5823 1 37 x49 (Single Hung) 2."FL5823 1 37 x0 (Single Hung) 3. FL5823 1 37 x49 (Single Hung) Owl O .4FL5823 1 37 x 4.9 +. (Single Hung) 5. FL5823 1 37)49 .� (Single Hung) , F 6. FL5823 1 37 x49 .(Single Hung) 'Q o 7 FL5823 1 36 x.37 Bath 1 7 (Single'Hung) Z (D M 8.,FL151771 52261 % (Double Hung) i— � 9 FL5823 1 :37x49 O =3(Single Hung) () 10 FI-582311, 37 x49 G N (Srngle ung.) O m 6 I Kitchen $ 7. 5 Office EntryLO c N 4 3 2 1 10 9 O V Z It ". CO Z LL�� .. C. ; O c LLiD o. .N N � -� WC') LL O 0 COPTRIGNi E�TEMPEST.COM SCALE: NOT TO SCALE .. DATE: Apr 27,2015 cy� PAGE DESCRIPTION: Site Plan T' c PAGE: OF1 t .i PARADISE EXTER, IORS "Building Our Quality Reputation One Customer At A Time SCC131150472 Property Information Building Information Owner: Doug&Elizabeth Wilcoxson Wind Zone: 170 MPH. Address: 5302 SUSON LN Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 40 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 37 49 157 37.2 -40.4 2 Int 37 49 7 37.2 -40.4 3 Int 37 49 7 37.2 -40.4 4 Int 37 49 7 37.2 -40.4 5 Int 37 49 7 37.2 -40.4 6 Int 37 49 7 37.2 -40.4 7 Int 36 37 7 37.8 -41.0 8 Int 52 61 7 35.9 -39.1 9 Int 37 49 7 37.2 -40.4 10 Int 37 49 7 37.2 -40.4 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.Florida Building Code 2010 ed. Page 1 of 1 r V A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER + PSF TESTED MULLION ( ) (-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ Y/N/NA REQ YM 1 Int Window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No 2 Int Window 7/8Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No 3 Int window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No 4 Int Window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No 5 Int Window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No 6 Int Window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No 7 Int Window 7/8 Lami FL5823.1 67.5 67.5 37.8 -41.0 5306 3607 No No 8 Int Window 7/8"Lami IG FL15177.1 70 70 35.9 -39.1 56x91 52x61 No No 9 Int Window vs°Lami FL5823.1 67.5 67.5 37.2 -40.4 1 5306 37x49 Yes No 10 Int Window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No