HomeMy WebLinkAboutDrawing Opening Size .
(WxH)
1.'FL5823 1 37 x49
(Single Hung)
2."FL5823 1 37 x0
(Single Hung)
3. FL5823 1 37 x49
(Single Hung) Owl O
.4FL5823 1 37 x 4.9 +.
(Single Hung)
5. FL5823 1 37)49
.�
(Single Hung) , F
6. FL5823 1 37 x49
.(Single Hung) 'Q o
7 FL5823 1 36 x.37 Bath 1 7
(Single'Hung) Z (D
M
8.,FL151771 52261 %
(Double Hung) i— �
9 FL5823 1 :37x49 O =3(Single Hung) ()
10 FI-582311, 37 x49 G N
(Srngle ung.) O
m
6 I Kitchen $
7.
5 Office EntryLO
c
N
4 3 2 1 10 9 O
V Z It
". CO
Z LL�� .. C. ; O
c LLiD
o. .N N
� -�
WC')
LL
O
0
COPTRIGNi E�TEMPEST.COM
SCALE:
NOT TO SCALE
.. DATE:
Apr 27,2015
cy� PAGE DESCRIPTION:
Site Plan
T' c
PAGE: OF1
t .i
PARADISE EXTER, IORS
"Building Our Quality Reputation
One Customer At A Time
SCC131150472
Property Information Building Information
Owner: Doug&Elizabeth Wilcoxson Wind Zone: 170 MPH.
Address: 5302 SUSON LN Exposure Category: C
FORT PIERCE,FL 34951 Minimum Building Dimension: 40 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 37 49 157 37.2 -40.4
2 Int 37 49 7 37.2 -40.4
3 Int 37 49 7 37.2 -40.4
4 Int 37 49 7 37.2 -40.4
5 Int 37 49 7 37.2 -40.4
6 Int 37 49 7 37.2 -40.4
7 Int 36 37 7 37.8 -41.0
8 Int 52 61 7 35.9 -39.1
9 Int 37 49 7 37.2 -40.4
10 Int 37 49 7 37.2 -40.4
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.Florida Building Code 2010 ed.
Page 1 of 1
r
V
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER + PSF TESTED MULLION
( ) (-)PSF (+)PSF (-)PSF SIZE DIMENSIONS REQ Y/N/NA REQ YM
1 Int Window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No
2 Int Window 7/8Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No
3 Int window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No
4 Int Window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No
5 Int Window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No
6 Int Window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No
7 Int Window 7/8 Lami FL5823.1 67.5 67.5 37.8 -41.0 5306 3607 No No
8 Int Window 7/8"Lami IG FL15177.1 70 70 35.9 -39.1 56x91 52x61 No No
9 Int Window vs°Lami FL5823.1 67.5 67.5 37.2 -40.4 1 5306 37x49 Yes No
10 Int Window 7/8"Lami FL5823.1 67.5 67.5 37.2 -40.4 5306 37x49 Yes No